-- File Name : HORIZON-IDU-MIB.mib
-- Version : 1.0.0
-- Date : April 16th, 2008
-- Author : DragonWave Inc.
DRAGONWAVE-HORIZON-IDU-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter, Gauge,TimeTicks
FROM RFC1155-SMI
snmp
FROM SNMPv2-MIB
OBJECT-TYPE, ifIndex
FROM IF-MIB
horizon
FROM HORIZON-MIB;
PhysAddress ::= OCTET STRING
DisplayString ::= OCTET STRING
-- Important!! For HP OpenView, the following OID definition for ISO must be commented out,
-- otherwise it won't compile. HP openView has already defined ISO.
-- iso OBJECT IDENTIFIER ::= { 1 }
horizonIdu OBJECT IDENTIFIER
::= { horizon 3 }
--
-- Node definitions
--
hzIduSystem OBJECT IDENTIFIER
::= { horizonIdu 1 }
hzIduAuthentication OBJECT IDENTIFIER
::= { horizonIdu 2 }
hzIduNetworkManagement OBJECT IDENTIFIER
::= { horizonIdu 3 }
hzIduNetworkInterface OBJECT IDENTIFIER
::= { horizonIdu 4 }
hzIduWirelessInterface OBJECT IDENTIFIER
::= { horizonIdu 5 }
hzIduCalendar OBJECT IDENTIFIER
::= { horizonIdu 6 }
hzIduAlarms OBJECT IDENTIFIER
::= { horizonIdu 7 }
hzIduTrapConfig OBJECT IDENTIFIER
::= { horizonIdu 8 }
hzIduSnmp OBJECT IDENTIFIER
::= { horizonIdu 9 }
hzIduManagementSessions OBJECT IDENTIFIER
::= { horizonIdu 10 }
hzIduHttp OBJECT IDENTIFIER
::= { horizonIdu 11 }
hzIduQos OBJECT IDENTIFIER
::= { horizonIdu 12 }
hzIduRapidLinkShutdown OBJECT IDENTIFIER
::= { horizonIdu 13 }
hzIduSntp OBJECT IDENTIFIER
::= { horizonIdu 14 }
hzIduLogs OBJECT IDENTIFIER
::= { horizonIdu 15 }
hzIduRadius OBJECT IDENTIFIER
::= { horizonIdu 16 }
-- -------------
-- hzIduSystem
-- -------------
hzIduSysGeneral OBJECT IDENTIFIER
::= { hzIduSystem 1 }
hzIduSysUpgradeSpeed OBJECT IDENTIFIER
::= { hzIduSystem 2 }
hzIduSysDowngradeSpeed OBJECT IDENTIFIER
::= { hzIduSystem 3 }
hzIduSysUpgradeWirelessPorts OBJECT IDENTIFIER
::= { hzIduSystem 4 }
hzIduSysSpeed OBJECT IDENTIFIER
::= { hzIduSystem 5 }
hzIduInventory OBJECT IDENTIFIER
::= { hzIduSystem 6 }
hzIduAtpc OBJECT IDENTIFIER
::= { hzIduSystem 7 }
hzIduAam OBJECT IDENTIFIER
::= { hzIduSystem 8 }
hzIduPeerSysInfo OBJECT IDENTIFIER
::= { hzIduSystem 9 }
-- ----------------------------
-- hzIduGeneral
-- ----------------------------
hzIduResetSystem OBJECT-TYPE
SYNTAX INTEGER { reset ( 1 ) }
ACCESS write-only
STATUS mandatory
DESCRIPTION "Writing '1' to this object resets the NIC, Modem, and radio."
::= { hzIduSysGeneral 1 }
hzIduSaveMIB OBJECT-TYPE
SYNTAX INTEGER { save ( 1 ) }
ACCESS write-only
STATUS mandatory
DESCRIPTION "Writing '1' or 'save' to this object save all MIB values."
::= { hzIduSysGeneral 2 }
hzIduOperStatus OBJECT-TYPE
SYNTAX INTEGER { up ( 1 ) , down ( 2 ) , testing ( 3 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current operational state of the system.
Testing indicates that no operational packets can be passed."
::= { hzIduSysGeneral 3 }
hzIduAirInterfaceEncryption OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "OBSOLETE. This enables encryption on the air interface. "
DEFVAL { disabled }
::= { hzIduSysGeneral 4 }
hzIduSystemCapacityOption OBJECT-TYPE
SYNTAX INTEGER { singleModem-singleRadio ( 1 ),
multiModem-singleRadio ( 2 ),
multiModem-multiRadio ( 3 ),
singleModem-redundancy ( 4 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Sets the system capacity options. There are four options:
Select 'singleModem-singleRadio' for a 400Mbps system.
Select 'multiModem-singleRadio' for 800Mbps when the system is equipped with an internal or external IF Coupler.
Select 'multiModem-multiRadio' for 800Mbps when the system is equipped with two radios connected to a Dual Polarization Radio Mount (DPRM).
Select 'singleModem-redundancy' to provide a redundant 400Mbps link using a Redundant Dual Radio Mount (RDRM).
Notes:
Setting the system capacity to 'singleModem-redundancy will fail if the primary path has not been set to either wireless_port1 or wireless_port2.
Setting the system capacity to 'multiModem-multiRadio' will set the transmit power of wireless_port2 to the same transmite power as wireless_port1."
DEFVAL { singleModem-singleRadio }
::= { hzIduSysGeneral 5 }
-- ----------------------------
-- hzIduSysUpgradeSpeed
-- ----------------------------
hzIduLicensedSpeedUpgradeSpeedAndKey OBJECT-TYPE
SYNTAX DisplayString
ACCESS write-only
STATUS mandatory
DESCRIPTION "Enter your apngFLEX key here along with the maximum speed for that key to upgrade the FLEX system.
Format: [speed] [key]
Example: 800 abc123"
::= { hzIduSysUpgradeSpeed 1 }
hzIduLicensedSpeedChanges OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This object indicates the number of times the licensed speed has been changed successfully. It is used when generating new license keys for your system."
::= { hzIduSysUpgradeSpeed 2 }
-- ----------------------------
-- hzIduSysDowngradeSpeed
-- ----------------------------
hzIduLicensedSpeedDowngradeSpeed OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS mandatory
DESCRIPTION "Reduce your licensed speed by entering a speed to this write-only object and take note of the generated key in hzIduDowngradeLicensedSpeedKey.
Format: [speed]
Example: 200"
::= { hzIduSysDowngradeSpeed 1 }
hzIduLicensedSpeedCountUsedForKey OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This object indicates the number of times the licensed speed has been changed successfully. It is used when generating new license keys for your system."
::= { hzIduSysDowngradeSpeed 2 }
hzIduLicensedSpeedDowngradeKey OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This read-only object will show a 'key' after successfully downgrading the license speed."
::= { hzIduSysDowngradeSpeed 3 }
-- ----------------------------
-- hzIduSysUpgradeWirelessPorts
-- ----------------------------
hzIduLicensedWirelessPortsUpgradeKey OBJECT-TYPE
SYNTAX DisplayString
ACCESS write-only
STATUS mandatory
DESCRIPTION "Hardware upgrade license key. Upgrade the number of active wireless ports by setting a valid license key."
::= { hzIduSysUpgradeWirelessPorts 1 }
hzIduLicensedWirelessPortsChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "This object indicates the number of times the wireless port count has been changed successfully. It is used when generating new license keys for your system. Currently, there is no SNMP object for downgrading the number of wireless ports."
::= { hzIduSysUpgradeWirelessPorts 2 }
-- ----------------------------
-- hzIduSysSpeed
-- ----------------------------
hzIduSystemCurrentSpeed OBJECT-TYPE
SYNTAX INTEGER ( 0..1000 )
ACCESS read-write
STATUS mandatory
DESCRIPTION "Changes the working speed of the horizon. Writes are only valid if system is a FLEX. Due to backwards compatibility issue, 0 value should be treated as 0 Mbps."
::= { hzIduSysSpeed 1 }
hzIduSystemLicensedSpeed OBJECT-TYPE
SYNTAX INTEGER ( 0..1000 )
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the maximum speed that this system can operate at. Due to backwards compatibility issue, 0 value should be treated as 0 Mbps."
::= { hzIduSysSpeed 2 }
-- --------------------------------------------------------------------------
-- The following System Modes were taken from the frequency file generated
-- with the following version and date:
-- FrequencyFilePartNumber :VDD-67-001112-01
-- Version :1.0.95
-- Date :10-Mar-2008
-- --------------------------------------------------------------------------
hzIduSystemMode OBJECT-TYPE
SYNTAX INTEGER {
cw-test(1),
hz50-67-qpsk(5),
hz50-110-16qam(6),
hz50-171-32qam(7),
hz50-215-64qam(8),
hz50-271-128qam(9),
hz50-322-256qam(10),
hz50-364-256qam(40), -- note out of numerical order
hz50-371-256qam(11),
hz56-65-qpsk(12),
hz56-111-16qam(13),
hz56-216-32qam(14),
hz56-290-128qam(15),
hz56-385-256qam(16),
hz28-37-qpsk(17),
hz28-48-qpsk(18),
hz28-71-16qam(19),
hz28-100-32qam(20),
hz28-144-128qam(21),
hz28-190-256qam(22),
hz14-23-qpsk(23),
hz14-36-16qam(24),
hz14-47-32qam(25),
hz14-70-128qam(26),
hz14-95-256qam(27),
hz40-57-qpsk(28),
hz40-58-qpsk(29),
hz40-110-32qam(30),
hz40-111-16qam(31),
hz40-142-32qam(32),
hz40-181-64qam(33),
hz40-200-128qam(34),
hz40-212-128qam(35),
hz40-277-256qam(36),
hz30-107-32qam(37),
hz30-165-128qam(38),
hz30-212-256qam(39)
-- hz50-364-256qam(40) relocated with hz50
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "Indicates the specific type of system this is."
::= { hzIduSysSpeed 3 }
-- ----------------------------
-- hzIduInventory
-- ----------------------------
hzIduHwInventory OBJECT IDENTIFIER
::= { hzIduInventory 1 }
hzIduSwInventory OBJECT IDENTIFIER
::= { hzIduInventory 2 }
-- ----------------------------
-- hzIduHwInventory
-- ----------------------------
hzIduFrequencyFilePartNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "A textual string containing Part Number of the Frequency File"
::= { hzIduHwInventory 1 }
hzIduUnitSerialNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "A textual string containing Serial Number of the Unit."
::= { hzIduHwInventory 2 }
hzIduUnitAssemblylNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "A textual string containing the Assembly Number of the Unit."
::= { hzIduHwInventory 3 }
hzIduIfSerialNo1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "A textual string containing Serial no of IF 1."
::= { hzIduHwInventory 4 }
hzIduIfSerialNo2 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "A textual string containing Serial no of IF 2."
::= { hzIduHwInventory 5 }
hzIduIfAssemblylNo1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "A textual string containing assembly no of IF 1."
::= { hzIduHwInventory 6 }
hzIduIfAssemblylNo2 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "A textual string containing assembly no of IF 2."
::= { hzIduHwInventory 7 }
hzIduNccSerialNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "A textual string containing Serial no of the NCC."
::= { hzIduHwInventory 10 }
hzIduNccAssemblylNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "A textual string containing assembly no of the NCC."
::= { hzIduHwInventory 11 }
hzIduRadio1SerialNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "A textual string containing the serial number of radio 1"
::= { hzIduHwInventory 12 }
hzIduRadio2SerialNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "A textual string containing the serial number of radio 2 if configured"
::= { hzIduHwInventory 13 }
hzIduRadio1HardwareId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "A textual string containing the hardware id of radio 1"
::= { hzIduHwInventory 14 }
hzIduRadio2HardwareId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "A textual string containing the hardware id of radio 2 if configured"
::= { hzIduHwInventory 15 }
hzIduInternalIFCouplerPresent OBJECT-TYPE
SYNTAX INTEGER { not-present ( 1 ) , present ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute indicates if there is an internal IF Coupler card present."
::= { hzIduHwInventory 16 }
hzIduHwWirelessPortsLicensed OBJECT-TYPE
SYNTAX INTEGER ( 1..2 )
ACCESS read-only
STATUS mandatory
DESCRIPTION "The number of licensed wireless ports. Upgrade this to 2 ports by setting the hardware upgrade license key."
::= { hzIduHwInventory 17 }
-- ----------------------------
-- hzIduSwInventory
-- ----------------------------
hzIduSwInvSystemOmniVersionNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The version number of the Omni."
::= { hzIduSwInventory 1 }
hzIduSwInvModemOmniVersionNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The version number of the Modem FPGA."
::= { hzIduSwInventory 2 }
hzIduSwInvFrequencyFileVersionNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The version number of the FrequencyFile."
::= { hzIduSwInventory 3 }
hzIduSwInvMibVersionNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The version number of the MIB."
::= { hzIduSwInventory 4 }
hzIduSwInvRadio1FirmwareVersionNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The version of radio 1 firmware."
::= { hzIduSwInventory 5 }
hzIduSwInvRadio2FirmwareVersionNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The version of radio 2 firmware."
::= { hzIduSwInventory 6 }
-- ----------------------------
-- hzIduAtpc
-- ----------------------------
hzIduAtpcEnable OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Indicates whether Automatic Transmit Power Control (ATPC) is enabled."
DEFVAL { disabled }
::= { hzIduAtpc 1 }
hzIduAtpcStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the actual condition of ATPC:
Enabled <20> if config is on and no issues
Auto-Disabled <20> if ATPC coordinated power condition, AAM triggered, or radio loss of link
Disabled-manual <20> if config set to off"
::= { hzIduAtpc 2 }
hzIduAtpcCoordinatedPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "
The Coordinated Power can be enabled by specifying the coordinated power status and coordinated power offset in a string with the following format (without the single quotes):
'<on [offset] | off>'
The offset can optionally be specified after the 'on' string and after a single space and can be be between 0.0 and 10.0 inclusive. The 'offset' is represented in dBm and indicates the offset below TxPower. The accuracy is limited to tenths of dBm so an offset of 9.99 is recognized as 9.9 dBm.
Examples: 'on 5.5' or 'off'"
::= { hzIduAtpc 3 }
-- ----------------------------
-- hzIduAam
-- ----------------------------
hzIduAamStatus OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Read or set the Automatic Adaptive Modulation (AAM) as 'on' or 'off'."
DEFVAL { disabled }
::= { hzIduAam 1 }
hzIduAamDiagnostics OBJECT IDENTIFIER
::= { hzIduAam 2 }
-- ----------------------------
-- hzIduAamDiagnostics
-- ----------------------------
hzIduAamDiagnose OBJECT-TYPE
SYNTAX INTEGER { up ( 1 ) , down ( 2 ) }
ACCESS write-only
STATUS mandatory
DESCRIPTION "This write-only object accepts either 'up' or 'down' to diagnose whether the modulation speed can be increased or decreased respectively. Poll the hzIduAamDiagnosticResult object to determine the results."
::= { hzIduAamDiagnostics 1 }
hzIduAamDiagnosticResult OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The result from AAM Diagnostic is read from this object."
::= { hzIduAamDiagnostics 2 }
-- ----------------------
-- hzIduPeerSysInfo
-- ---------------------
hzIduPeerMacAddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The MAC Address of the peer network interface card."
::= { hzIduPeerSysInfo 1 }
hzIduPeerIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION "The IP Address of the peer network interface card."
::= { hzIduPeerSysInfo 2 }
hzIduPeerSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION "The subnet mask for the peer network interface card."
::= { hzIduPeerSysInfo 3 }
--- ----------------------------
-- hzIduAuthentication
-- ----------------------------
hzIduUniquePeerAuthenticationKey OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 34 ) )
ACCESS read-write
STATUS mandatory
DESCRIPTION "The serial number of the peer node that this node will communicate with.
This is only used when authentication mode is set to unique."
::= { hzIduAuthentication 1 }
hzIduPeerDetectedSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The serial number of the peer node that the system is presently communicating
with. This is only used when authentication is set to unique."
::= { hzIduAuthentication 2 }
hzIduAuthenticationMode OBJECT-TYPE
SYNTAX INTEGER { none ( 1 ) , unique ( 2 ) , group ( 3 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "This sets the authentication mode for the system.If configured for unique
authentication, an horizon node only exchanges user traffic with one other
horizon node. The serial number is used in this case.
If configured for group authentication, an horizon node exchanges user
traffic with another horizon node of the same group and uses the
authentication keys."
DEFVAL { none }
::= { hzIduAuthentication 3 }
hzIduAuthenticationFailureAction OBJECT-TYPE
SYNTAX INTEGER { blockTraffic ( 1 ) , passTraffic ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "This sets the authentication failure action for the system.
Block traffic will block all user traffic including remote
management access. Pass traffic will allow all user traffic
to be sent and recieved"
DEFVAL { blockTraffic }
::= { hzIduAuthentication 4 }
hzIduPeerAuthenticationStatus OBJECT-TYPE
SYNTAX INTEGER { notAuthenticated ( 1 ) , authenticated ( 2 ) ,explicitAuthenticationFailure ( 3 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Specifies the current authentication status of the system.
Authenticated means authentication is on and the system
has been authenticated, notAuthenticated means authentication
is off or the system has not communicated yet with the other node,
explicit authentication failure means authentication is on and
authentication has failed"
::= { hzIduAuthentication 5 }
--
-- NetworkManagement
--
hzIduMacAddress OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The MAC Address of the network interface card."
::= { hzIduNetworkManagement 1 }
hzIduNetworkManagementInterface OBJECT-TYPE
SYNTAX INTEGER { port1 ( 1 ) , port2 ( 2 ), port2Extended(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Describes the network management interface connection options."
::= { hzIduNetworkManagement 2 }
hzIduIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION "The IP Address of the network interface card."
::= { hzIduNetworkManagement 3 }
hzIduSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION "The subnet mask for the network interface card."
::= { hzIduNetworkManagement 4 }
hzIduDefaultGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION "The default gateway for the network interface card"
::= { hzIduNetworkManagement 5 }
hzIduTelnetAccessMode OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Indicates whether Telnet access is allowed."
DEFVAL { enabled }
::= { hzIduNetworkManagement 6 }
hzIduSshAccessMode OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Indicates whether ssh access is allowed."
DEFVAL { enabled }
::= { hzIduNetworkManagement 7 }
hzIduVlanTagEnable OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Indicates whether VLAN tagging is enabled."
DEFVAL { disabled }
::= { hzIduNetworkManagement 8 }
hzIduVlanTagId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION ""
DEFVAL { 0 }
::= { hzIduNetworkManagement 9 }
hzIduVlanTagPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION ""
DEFVAL { 0 }
::= { hzIduNetworkManagement 10 }
--
-- NETWORK CARD INFORMATION
--
hzIduEnetPort1 OBJECT IDENTIFIER
::= { hzIduNetworkInterface 1 }
hzIduEnetPort2 OBJECT IDENTIFIER
::= { hzIduNetworkInterface 2 }
hzIduEnetPort2Description OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Describes the functionality of the port2"
DEFVAL { on }
::= { hzIduEnetPort2 1 }
hzIduEnetPort2Config OBJECT IDENTIFIER
::= { hzIduEnetPort2 2 }
hzIduEnetPort2Status OBJECT IDENTIFIER
::= { hzIduEnetPort2 3 }
hzIduEnetPort2Stats OBJECT IDENTIFIER
::= { hzIduEnetPort2 4 }
hzIduEnetPort1Description OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Describes the functionality of the port1"
DEFVAL { on }
::= { hzIduEnetPort1 1 }
hzIduEnetPort1Config OBJECT IDENTIFIER
::= { hzIduEnetPort1 2 }
hzIduEnetPort1Status OBJECT IDENTIFIER
::= { hzIduEnetPort1 3 }
hzIduEnetPort1Stats OBJECT IDENTIFIER
::= { hzIduEnetPort1 4 }
--
-- hzIduEnetPort2Config
--
hzIduEnetPort2AutoNegotiation OBJECT-TYPE
SYNTAX INTEGER { on ( 1 ) , off ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Turns auto-negotiation on or off for Ethernet Port2. Turning off results in the interface defaulting to 100BaseT, Full Duplex. "
DEFVAL { on }
::= { hzIduEnetPort2Config 1 }
hzIduEnetPort2Speed OBJECT-TYPE
SYNTAX INTEGER { x10M( 1 ) , x100M( 2 ), x1000M( 3 ), auto(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Configure the port1 interface speed ."
::= { hzIduEnetPort2Config 2}
hzIduEnetPort2Duplex OBJECT-TYPE
SYNTAX INTEGER { full( 1 ) , half( 2 ), auto( 3 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Configure the port1 interface duplex."
::= { hzIduEnetPort2Config 3}
hzIduEnetPort2AdminState OBJECT-TYPE
SYNTAX INTEGER { on( 1 ) , off( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Configure the port2 shutdown media."
::= { hzIduEnetPort2Config 4}
--
-- Port2 STATUS
--
hzIduEnetPort2LinkStatus OBJECT-TYPE
SYNTAX INTEGER { down ( 1 ) , up( 2 ) , invalid( 3 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the Port2 link status."
::= { hzIduEnetPort2Status 1}
hzIduEnetPort2AutoNegotiationStatus OBJECT-TYPE
SYNTAX INTEGER { on( 1 ) , off( 2 ) ,invalid(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the Port2 AutoNegotiation status."
::= { hzIduEnetPort2Status 2}
hzIduEnetPort2SpeedStatus OBJECT-TYPE
SYNTAX INTEGER { x10M( 1 ) , x100M( 2 ), x1000M( 3 ), auto(4) ,invalid(5)}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the Port2 interface speed status."
::= { hzIduEnetPort2Status 3}
hzIduEnetPort2DuplexStatus OBJECT-TYPE
SYNTAX INTEGER { full( 1 ) , half( 2 ), auto( 3 ), invalid(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the Port2 interface duplex status."
::= { hzIduEnetPort2Status 4}
--
-- Port2 STATISTICS
--
hzIduEnetPort2TxFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of Port2 frames sent."
::= { hzIduEnetPort2Stats 1 }
hzIduEnetPort2TxBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of Port2 bytes sent."
::= { hzIduEnetPort2Stats 2 }
hzIduEnetPort2RxFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of Port2 frames received."
::= { hzIduEnetPort2Stats 3 }
hzIduEnetPort2RxBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of Port2 bytes received."
::= { hzIduEnetPort2Stats 4 }
hzIduEnetPort2RxFramesInErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of Port2 frames received in error."
::= { hzIduEnetPort2Stats 5 }
hzIduEnetPort2RxFramesCrcErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of CRC error frames received for Port2."
::= { hzIduEnetPort2Stats 6 }
--
-- PORT1 CONFIG
--
hzIduEnetPort1AutoNegotiation OBJECT-TYPE
SYNTAX INTEGER { on( 1 ) , off ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Turns auto-negotiation on or off for Ethernet Port1. Turning off results in the interface defaulting to 100BaseT, Full Duplex. "
DEFVAL { on }
::= { hzIduEnetPort1Config 1 }
hzIduEnetPort1Speed OBJECT-TYPE
SYNTAX INTEGER { x10M( 1 ) , x100M( 2 ), x1000M( 3 ), auto(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Configure the port1 interface speed ."
::= { hzIduEnetPort1Config 2}
hzIduEnetPort1Duplex OBJECT-TYPE
SYNTAX INTEGER { full( 1 ) , half( 2 ), auto( 3 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Configure the port1 interface duplex."
::= { hzIduEnetPort1Config 3}
hzIduEnetPort1Media OBJECT-TYPE
SYNTAX INTEGER { copper( 1 ) , fiber( 2 ), auto( 3 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Configure the port1 interface media."
::= { hzIduEnetPort1Config 4}
hzIduEnetPort1AdminState OBJECT-TYPE
SYNTAX INTEGER { on( 1 ) , off( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Configure the port1 interface media."
::= { hzIduEnetPort1Config 5}
hzIduEnetPort1OpticalTransceiverState OBJECT-TYPE
SYNTAX INTEGER { on ( 1 ) , off ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "When it is on, optical transmitter for port1 is enabled. Otherwise optical transmitter is disabled."
DEFVAL { off }
::= { hzIduEnetPort1Config 6 }
hzIduEnetPort1PauseFrameEnable OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "When PAUSE is enabled, port1 pause frames can be generated by the
system and the pause frames will flow toward the link partner
on the network. When PAUSE is not enabled,
no pause frames will be generated by the system. "
DEFVAL { disabled }
::= { hzIduEnetPort1Config 7 }
hzIduEnetPort1MaxFrameSize OBJECT-TYPE
SYNTAX INTEGER ( 1600..9600 )
ACCESS read-write
STATUS mandatory
DESCRIPTION "For port1 the default maximum frame size is 1600 bytes. The settable
maximum frame size must be a multiple of 128. If the chosen
maximum frame size is not a multiple of 128, its closest
number which is a multiple of 128 is actually used. The
settable lowest maximum frame size is 1664, and the settable
highest maximum frame size is 9600. If the chosen maximum
frame size is out of this range, the default maximum frame
size of 1600 is used. "
DEFVAL { 1600 }
::= { hzIduEnetPort1Config 8 }
hzIduEnetPort1DroppedEnetFramesThresholdParameters OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
ACCESS read-write
STATUS mandatory
DESCRIPTION "A read-write string: The threshold, in percent, and the number of seconds that it must exceed this threshold are programmed by the user. An example of the format of the string is as follows: '70 10'. The first parameter is the percentage of frames that are dropped, the second is the time in seconds that the threshold must be exceeded. The single quote marks i.e. ' ' are not used in the command."
::= { hzIduEnetPort1Config 9 }
hzIduEnetPort1BandwidthUtilizationThresholdParameters OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
ACCESS read-write
STATUS mandatory
DESCRIPTION "A read-write string: The percentage of available bandwidth threshold and the number of seconds that it must exceed this threshold are programmed by the user. An example of the format of the string is as follows: '70 10'. The first parameter is the threshold point in percent, the number of seconds that the threshold must be exceeded. The single quote marks i.e. ' ' are not used in the command."
::= { hzIduEnetPort1Config 10 }
--
-- PORT1 STATUS
--
hzIduEnetPort1LinkStatus OBJECT-TYPE
SYNTAX INTEGER { down ( 1 ) , up( 2 ) , invalid( 3 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the port1 link status."
::= { hzIduEnetPort1Status 1}
hzIduEnetPort1AutoNegotiationStatus OBJECT-TYPE
SYNTAX INTEGER { on( 1 ) , off( 2 ),invalid(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the port1 AutoNegotiation status."
::= { hzIduEnetPort1Status 2}
hzIduEnetPort1SpeedStatus OBJECT-TYPE
SYNTAX INTEGER { x10M( 1 ) , x100M( 2 ), x1000M( 3 ), auto(4) ,invalid(5)}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the port1 interface speed status."
::= { hzIduEnetPort1Status 3}
hzIduEnetPort1DuplexStatus OBJECT-TYPE
SYNTAX INTEGER { full( 1 ) , half( 2 ), auto( 3 ) ,invalid(4)}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the port1 interface duplex status."
::= { hzIduEnetPort1Status 4}
hzIduEnetPort1MediaStatus OBJECT-TYPE
SYNTAX INTEGER { copper( 1 ) , fiber( 2 ), auto( 3 ),invalid(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the port1 interface media status."
::= { hzIduEnetPort1Status 5}
--
-- PORT1 STATISTICS
--
hzIduEnetPort1TxFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of port1 frames sent."
::= { hzIduEnetPort1Stats 1 }
hzIduEnetPort1TxBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of port1 bytes sent."
::= { hzIduEnetPort1Stats 2 }
hzIduEnetPort1RxFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of port1 frames received."
::= { hzIduEnetPort1Stats 3 }
hzIduEnetPort1RxBytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of port1 bytes received."
::= { hzIduEnetPort1Stats 4 }
hzIduEnetPort1RxFramesInErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of port1 frames received in error."
::= { hzIduEnetPort1Stats 5 }
hzIduEnetPort1RxFramesCRCErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of CRC error frames received for port1."
::= { hzIduEnetPort1Stats 6 }
hzIduEnetPort1BWUtilization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The carried load over link capacity for port1."
::= { hzIduEnetPort1Stats 7 }
hzIduEnetPort1IngressDataRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The data rate coming into the ethernet for port1.
The data rate you see is multiplied by 100. e.g. A display
of 1530 is actually 15.30 Mpbs"
::= { hzIduEnetPort1Stats 8 }
hzIduEnetPort1EgressDataRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The data rate going out of the ethernet for port1.
The data rate you see is multiplied by 100. e.g. A display
of 1530 is actually 15.30 Mpbs."
::= { hzIduEnetPort1Stats 9 }
hzIduEnetPort1FramesInQueue1s OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of port1 frames passed through queue 1."
::= { hzIduEnetPort1Stats 10 }
hzIduEnetPort1FramesInQueue2s OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of port1 frames passed through queue 2."
::= { hzIduEnetPort1Stats 11 }
hzIduEnetPort1FramesInQueue3s OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of NIC frames passed through queue 3."
::= { hzIduEnetPort1Stats 12 }
hzIduEnetPort1FramesInQueue4s OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of NIC frames passed through queue 4."
::= { hzIduEnetPort1Stats 13 }
hzIduEnetPort1FramesInQueue1Discardeds OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of NIC frames received in queue 2 that
were discarded, but due to an error. One possible reason
is lack of buffer space."
::= { hzIduEnetPort1Stats 14 }
hzIduEnetPort1FramesInQueue2Discardeds OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of port1 frames received in queue 2 that
were discarded, but due to an error. One possible reason
is lack of buffer space."
::= { hzIduEnetPort1Stats 15 }
hzIduEnetPort1FramesInQueue3Discardeds OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of port1 frames received in queue 3 that
were discarded, but due to an error. One possible reason
is lack of buffer space."
::= { hzIduEnetPort1Stats 16 }
hzIduEnetPort1FramesInQueue4Discardeds OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of port1 frames received in queue 4 that
were discarded, but due to an error. One possible reason
is lack of buffer space."
::= { hzIduEnetPort1Stats 17 }
-- ----------------------------
-- hzIduWirelessInterface
-- ----------------------------
hzIduWirelessInterfaceNames OBJECT IDENTIFIER
::= { hzIduWirelessInterface 1 }
hzIduWirelessInterfaceModems OBJECT IDENTIFIER
::= { hzIduWirelessInterface 2 }
hzIduWirelessInterfaceIFCards OBJECT IDENTIFIER
::= { hzIduWirelessInterface 3 }
hzIduWirelessInterfaceRadios OBJECT IDENTIFIER
::= { hzIduWirelessInterface 4 }
hzIduWirelessInterfaceRadioFrequencies OBJECT IDENTIFIER
::= { hzIduWirelessInterface 5 }
hzIduWirelessInterfaceAntenna OBJECT IDENTIFIER
::= { hzIduWirelessInterface 6 }
hzIduWirelessInterfaceRedundancy OBJECT IDENTIFIER
::= { hzIduWirelessInterface 7 }
-- -----------------------------
-- hzIduWirelessInterfaceNames
-- -----------------------------
hzIduWirelessInterfaceNameTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduWirelessInterfaceNameEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table of Wireless Interface Modems"
::= { hzIduWirelessInterfaceNames 1 }
hzIduWirelessInterfaceNameEntry OBJECT-TYPE
SYNTAX HzIduWirelessInterfaceNameEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A Wireless Interface Modem"
INDEX { hzIduWirelessInterfaceNameIndex }
::= { hzIduWirelessInterfaceNameTable 1 }
HzIduWirelessInterfaceNameEntry ::= SEQUENCE {
hzIduWirelessInterfaceNameIndex INTEGER,
hzIduWirelessInterfaceName DisplayString
}
hzIduWirelessInterfaceNameIndex OBJECT-TYPE
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each interface. "
::= { hzIduWirelessInterfaceNameEntry 1 }
hzIduWirelessInterfaceName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Describes the functionality of the Wireless Interface"
::= { hzIduWirelessInterfaceNameEntry 2 }
-- -----------------------------
-- hzIduWirelessInterfaceIFCards
-- -----------------------------
hzIduIntermediateFrequencyCardTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduIntermediateFrequencyCardEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table of Wireless Interface Modems"
::= { hzIduWirelessInterfaceIFCards 1 }
hzIduIntermediateFrequencyCardEntry OBJECT-TYPE
SYNTAX HzIduIntermediateFrequencyCardEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A Wireless Interface Modem"
INDEX { hzIduIFCardIndex }
::= { hzIduIntermediateFrequencyCardTable 1 }
HzIduIntermediateFrequencyCardEntry ::= SEQUENCE {
hzIduIFCardIndex INTEGER,
hzIduIFCardTxSynthesizerLock INTEGER,
hzIduIFCardRxSynthesizerLock INTEGER
}
hzIduIFCardIndex OBJECT-TYPE
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each interface. "
::= { hzIduIntermediateFrequencyCardEntry 1 }
hzIduIFCardTxSynthesizerLock OBJECT-TYPE
SYNTAX INTEGER { unlocked ( 1 ), locked ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates if the transmit synthesizer is locked."
::= { hzIduIntermediateFrequencyCardEntry 2 }
hzIduIFCardRxSynthesizerLock OBJECT-TYPE
SYNTAX INTEGER { unlocked ( 1 ), locked ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates if the receive synthesizer is locked."
::= { hzIduIntermediateFrequencyCardEntry 3 }
-- -----------------------------
-- hzIduWirelessInterfaceModems
-- -----------------------------
hzIduAggregatedWirelessPortStats OBJECT IDENTIFIER
::= { hzIduWirelessInterfaceModems 1 }
hzIduAggregatedWirelessPortTxFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of Ethernet Combiner frames sent."
::= { hzIduAggregatedWirelessPortStats 1 }
hzIduAggregatedWirelessPortRxFramesOKs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of good Ethernet Combiner frames received."
::= { hzIduAggregatedWirelessPortStats 2 }
hzIduAggregatedWirelessPortRxFrameErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of Ethernet Combiner frames received in error."
::= { hzIduAggregatedWirelessPortStats 3 }
hzIduAggregatedWirelessPortRxFramesQueueDiscards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of Ethernet Combiner frames in the queue that were discarded."
::= { hzIduAggregatedWirelessPortStats 4 }
-- ----------------
-- hzIduModemTable
-- ----------------
hzIduModemTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduModemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table of Wireless Interface Modems"
::= { hzIduWirelessInterfaceModems 2 }
hzIduModemEntry OBJECT-TYPE
SYNTAX HzIduModemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A Wireless Interface Modem"
INDEX { hzIduModemIndex }
::= { hzIduModemTable 1 }
HzIduModemEntry ::= SEQUENCE {
hzIduModemIndex INTEGER,
hzIduModemOperStatus INTEGER,
hzIduModemReset INTEGER,
hzIduModemChannelizedRSL INTEGER,
hzIduModemChannelizedRSLUnsignedInt INTEGER,
hzIduModemModulationType INTEGER,
hzIduModemRxSpeed INTEGER,
hzIduModemTxSpeed INTEGER,
hzIduModemSNR INTEGER,
hzIduModemEbToNoiseRatio INTEGER,
hzIduModemEqualizerStress INTEGER,
hzIduModemSNRThresholdParameters DisplayString,
hzIduModemChannelizedRslBelowThresholdParameters DisplayString
}
hzIduModemIndex OBJECT-TYPE
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each interface. "
::= { hzIduModemEntry 1 }
hzIduModemOperStatus OBJECT-TYPE
SYNTAX INTEGER { up ( 1 ), down( 2 ), testing (3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current operational state of the interface. Testing indicates that no operational packets can be passed."
::= { hzIduModemEntry 2 }
hzIduModemReset OBJECT-TYPE
SYNTAX INTEGER ( 0 .. 1 )
ACCESS write-only
STATUS mandatory
DESCRIPTION "Writing 1 to this object causes the modem card to be reset.
All other values are not recognized. This variable always
reads back as 0. mdmOperStatus should be polled by the
user after this object is written to, to verify that the
modem card has been reset. Not applicable in this release"
::= { hzIduModemEntry 3 }
hzIduModemChannelizedRSL OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "An estimate of the modem's channelized RSL. Divide the value by 10 to get the actual RSL value. Once this number is divided by 10 the units are dBm. For example 352 is actually -35.2dBm"
::= { hzIduModemEntry 4 }
hzIduModemChannelizedRSLUnsignedInt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The absolute value of the estimate of the modem's channelized RSL. Divide the value by 10 to get the actual RSL value. Once this number is divided by 10 the units are dBm. For example -352 is actually -35.2dBm"
::= { hzIduModemEntry 5 }
hzIduModemModulationType OBJECT-TYPE
SYNTAX INTEGER { qpsk ( 1 ) , qam ( 2 ) , qam16 ( 3 ) , qam32 ( 4 ) , qam64 ( 5 ) , qam128 ( 6 ) , qam256 ( 7 ) , x8psk ( 8 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The modulation type of the modem, distinguished according
to the physical/link protocol."
::= { hzIduModemEntry 6 }
hzIduModemRxSpeed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "An estimate of the modem's current Rx bandwidth in bits per
second. Divide the value by 10000 to get the actual data rate in Mbps"
::= { hzIduModemEntry 7 }
hzIduModemTxSpeed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "An estimate of the modem's current Tx bandwidth in bits per
second. Divide the value by 10000 to get the actual data rate in Mbps"
::= { hzIduModemEntry 8 }
hzIduModemSNR OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "SNR value in dB. Divide the value by 10 to get the actual SNR."
::= { hzIduModemEntry 9 }
hzIduModemEbToNoiseRatio OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The ratio of the modem Estimated Energy per information bit to Noise power spectral density.
Divide the value by 10 to get the actual EbToNoiseRatio"
::= { hzIduModemEntry 10 }
hzIduModemEqualizerStress OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the average magnitude of all the equalizer taps to provide a measure of how hard the equalizer is working."
::= { hzIduModemEntry 11 }
hzIduModemSNRThresholdParameters OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
ACCESS read-write
STATUS mandatory
DESCRIPTION "A read-write string "
::= { hzIduModemEntry 12 }
hzIduModemChannelizedRslBelowThresholdParameters OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
ACCESS read-write
STATUS mandatory
DESCRIPTION "A read-write string: The threshold in dBm and the number of seconds threshold are programmed by the user. An example of the format of the string is as follows: '-75 10'. The first parameter power level in dBm, the second is the time in seconds that the threshold must be exceeded. In this example the threshold -75 dBm and the time is set to 10 seconds. The single quote marks i.e. ' ' are not used in the command."
::= { hzIduModemEntry 13 }
-- ----------------------------
-- hzIduWirelessInterfaceModems
-- ----------------------------
hzIduModemStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduModemStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table of Wireless Interface Modem Statistics"
::= { hzIduWirelessInterfaceModems 3 }
hzIduModemStatsEntry OBJECT-TYPE
SYNTAX HzIduModemStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Statistics for a Wireless Interface Modem"
INDEX { hzIduModemStatsIndex }
::= { hzIduModemStatsTable 1 }
HzIduModemStatsEntry ::= SEQUENCE {
hzIduModemStatsIndex INTEGER,
hzIduModemTxBlocks Counter,
hzIduModemRxBlocksOKs Counter,
hzIduModemRxBlocksErrors Counter
}
hzIduModemStatsIndex OBJECT-TYPE
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each interface. "
::= { hzIduModemStatsEntry 1 }
hzIduModemTxBlocks OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of Modem blocks transmitted."
::= { hzIduModemStatsEntry 2 }
hzIduModemRxBlocksOKs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of Modem blocks received."
::= { hzIduModemStatsEntry 3 }
hzIduModemRxBlocksErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current count of Modem blocks received in error."
::= { hzIduModemStatsEntry 4 }
--
-- RADIO INFORMATION
--
hzIduRadioTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduRadioEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table of Wireless Interface Radios"
::= { hzIduWirelessInterfaceRadios 1 }
hzIduRadioEntry OBJECT-TYPE
SYNTAX HzIduRadioEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A Wireless Interface Radio"
INDEX { hzIduRadioIndex }
::= { hzIduRadioTable 1 }
HzIduRadioEntry ::= SEQUENCE {
hzIduRadioIndex INTEGER,
hzIduRadioDescription DisplayString,
hzIduRadioOperStatus INTEGER,
hzIduRadioLastChanged TimeTicks,
hzIduRadioReceiveSignalLevel INTEGER,
hzIduRadioReceiveSignalLevelUnsigned INTEGER,
hzIduRadioTxGain INTEGER,
hzIduRadioRxGain INTEGER,
hzIduRadioReset INTEGER,
hzIduRadioTransmitPowerdBm INTEGER,
hzIduRadioPowerOption INTEGER,
hzIduRadioTxState INTEGER,
hzIduRadioTemperature INTEGER,
hzIduRadioRxCableLoss DisplayString,
hzIduRadioTxCableLoss DisplayString,
hzIduRadioTxCableLossChange DisplayString
}
hzIduRadioIndex OBJECT-TYPE
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each interface. "
::= { hzIduRadioEntry 1 }
hzIduRadioDescription OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "A textual string containing information about the radio. Includes the
manufacturer, product name, software version, serial number, and hardware
version of the radio."
::= { hzIduRadioEntry 2 }
hzIduRadioOperStatus OBJECT-TYPE
SYNTAX INTEGER { up ( 1 ) , down ( 2 ) , testing ( 3 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current operational state of the interface. Testing
indicates that no operational packets can be passed. Testing
also indicates that a firmware upgrade may be in progress"
::= { hzIduRadioEntry 3 }
hzIduRadioLastChanged OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "The value of sysUpTime at the time the radio entered its current
operational state. If the current state was entered prior to the
last re-initialization of the local network management subsystem,
then this object contains a zero value."
::= { hzIduRadioEntry 4 }
hzIduRadioReceiveSignalLevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Received Signal Level indicates the power of the receive level
in dBm. The number is divided by 10 to get the actual dBm. For example,
-432 is actually -43.2dBm."
::= { hzIduRadioEntry 5 }
hzIduRadioReceiveSignalLevelUnsigned OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Received Signal Level indicates the power of the receive level in dBm.
The number is divided by -10. e.g. 432 is actually -43.2dBm. Object provided
to accomodate plotting of negative RSL values which is not supported
in some EMS (i.e.: CastleRock). Please use 'hzIduRadioReceiveSignalLevel'
object if your EMS supports plotting of negative integers."
::= { hzIduRadioEntry 6 }
hzIduRadioTxGain OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The gain of the radio in the transmit chain. Indicates the gain in dB."
::= { hzIduRadioEntry 7 }
hzIduRadioRxGain OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The gain of the radio in the receive chain. Indicates the gain in dB."
::= { hzIduRadioEntry 8 }
hzIduRadioReset OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS mandatory
DESCRIPTION "Writing 1 to this object causes the radio to be reset. All other values
are not recognized. This variable always reads back as 0. radioOperStatus
should be polled by the user after this object is written to, to verify
that the radio card has been reset."
::= { hzIduRadioEntry 9 }
hzIduRadioTransmitPowerdBm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "This defines the transmit level of the radio. If ATPC or AAM is enabled, you can't change the transmit power.
The power you see is divided by 10. e.g. A display of 133 is actually 13.3 dBm.
If the radio is operational and not muted, it is the current transmitting power.
If the radio is operational and muted, it is the programmed transmitting power, and will transmit at this level when the radio is un-muted.
If the radio is not operational it is the programmed transmitting power, and will transmit at this level when the radio is operational and not muted.
If the radio does not have transmit calibration tables programmed into its EEPROM, this transmit power level cannot be used as it is not possible to accurately calculate the actual transmit level. In this case this object will return -99."
DEFVAL { 0 }
::= { hzIduRadioEntry 10 }
hzIduRadioPowerOption OBJECT-TYPE
SYNTAX INTEGER { normal ( 1 ) , highPower ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "This indicates the power option of the radio: normal or high power."
DEFVAL { 0 }
::= { hzIduRadioEntry 11 }
hzIduRadioTxState OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "This indicates the power option of the radio: normal or high power."
DEFVAL { 0 }
::= { hzIduRadioEntry 12 }
hzIduRadioTemperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Radio temperature in degree Celsius. The actual temperature is determined by dividing the number by 10. e.g. 202 is actually 20.2 degrees Celsius."
::= { hzIduRadioEntry 13 }
hzIduRadioRxCableLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Rx Cable Loss in dB."
::= { hzIduRadioEntry 14 }
hzIduRadioTxCableLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Tx Cable Loss in dB."
::= { hzIduRadioEntry 15 }
hzIduRadioTxCableLossChange OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Tx Cable Loss Change is the difference between the configured TxPower and the measured TxPower measured in dB."
::= { hzIduRadioEntry 16 }
-- --------------------------------------
-- hzIduWirelessInterfaceRadioFrequencies
-- --------------------------------------
hzIduWirelessInterfaceRadio1Frequencies OBJECT IDENTIFIER
::= { hzIduWirelessInterfaceRadioFrequencies 1 }
hzIduWirelessInterfaceRadio2Frequencies OBJECT IDENTIFIER
::= { hzIduWirelessInterfaceRadioFrequencies 2 }
-- --------------------------------------
-- hzIduWirelessInterfaceRadio1Frequencies
-- --------------------------------------
hzIduRadio1Band OBJECT-TYPE
-- ------------Don't forget to update Radio2 Band list! ------------------
SYNTAX INTEGER { freqNone (1), fcc11-1-40 (2), fcc11-1-30 (3), fcc18-2-40 (4), fcc18-2-50(5), fcc23-3-50(6) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "The radio frequency standard used for Radio 1. Frequency bands are divided into sub bands.
i.e. FCC 23 Ghz Band is comprised of fcc23a, fcc23b, fcc23c and
fcc23d which make up the entire FCC23 band"
DEFVAL { freqNone }
::= { hzIduWirelessInterfaceRadio1Frequencies 1 }
hzIduRadio1FreqGroupSelected OBJECT-TYPE
SYNTAX INTEGER { txLow ( 1 ) , txHigh ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "The frequency group selected for Radio 1.
The frequency subbands are divided into frequency groups txHigh and txLow. An horizon system must have one node configured to txLow and the other node configure to txHigh"
::= { hzIduWirelessInterfaceRadio1Frequencies 2 }
hzIduRadio1TxHighFreqTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduRadio1TxHighFreqEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table of txHigh frequency settings for Radio 1"
::= { hzIduWirelessInterfaceRadio1Frequencies 3 }
hzIduRadio1TxHighFreqEntry OBJECT-TYPE
SYNTAX HzIduRadio1TxHighFreqEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A txHighFrequency entry containing all the frequency values"
INDEX { hzIduRadio1TxHighFreqIndex }
::= { hzIduRadio1TxHighFreqTable 1 }
HzIduRadio1TxHighFreqEntry ::= SEQUENCE {
hzIduRadio1TxHighFreqIndex INTEGER,
hzIduRadio1TxHighFreqChannelIndex DisplayString,
hzIduRadio1TxHighFreqTransmitRfFrequency INTEGER,
hzIduRadio1TxHighFreqReceiveRfFrequency INTEGER,
hzIduRadio1TxHighFreqProgrammed INTEGER
}
hzIduRadio1TxHighFreqIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each frequency channel. "
::= { hzIduRadio1TxHighFreqEntry 1 }
hzIduRadio1TxHighFreqChannelIndex OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The channel index for the frequency."
::= { hzIduRadio1TxHighFreqEntry 2 }
hzIduRadio1TxHighFreqTransmitRfFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The RF TX frequency in KHz."
::= { hzIduRadio1TxHighFreqEntry 3 }
hzIduRadio1TxHighFreqReceiveRfFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The RF RX frequency in KHz."
::= { hzIduRadio1TxHighFreqEntry 4 }
hzIduRadio1TxHighFreqProgrammed OBJECT-TYPE
SYNTAX INTEGER { active ( 1 ) , notActive ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies the operating frequency channel for the modem.
***Only 1 index may be selected in a 1 modem system."
DEFVAL { notActive }
::= { hzIduRadio1TxHighFreqEntry 5 }
hzIduRadio1TxLowFreqTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduRadio1TxLowFreqEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table of txLow frequency settings for Radio 1"
::= { hzIduWirelessInterfaceRadio1Frequencies 4 }
hzIduRadio1TxLowFreqEntry OBJECT-TYPE
SYNTAX HzIduRadio1TxLowFreqEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A hzIduTxLowFrequeny entry containing the frequency values for a specific index"
INDEX { hzIduRadio1TxLowFreqIndex }
::= { hzIduRadio1TxLowFreqTable 1 }
HzIduRadio1TxLowFreqEntry ::= SEQUENCE {
hzIduRadio1TxLowFreqIndex INTEGER,
hzIduRadio1TxLowFreqChannelIndex DisplayString,
hzIduRadio1TxLowFreqTransmitRfFrequency INTEGER,
hzIduRadio1TxLowFreqReceiveRfFrequency INTEGER,
hzIduRadio1TxLowFreqProgrammed INTEGER
}
hzIduRadio1TxLowFreqIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each frequency channel. "
::= { hzIduRadio1TxLowFreqEntry 1 }
hzIduRadio1TxLowFreqChannelIndex OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The channel index for the frequency. "
::= { hzIduRadio1TxLowFreqEntry 2 }
hzIduRadio1TxLowFreqTransmitRfFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The RF TX frequency in KHz."
::= { hzIduRadio1TxLowFreqEntry 3 }
hzIduRadio1TxLowFreqReceiveRfFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The RF RX frequency in KHz."
::= { hzIduRadio1TxLowFreqEntry 4 }
hzIduRadio1TxLowFreqProgrammed OBJECT-TYPE
SYNTAX INTEGER { active ( 1 ) , notActive ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies the operating frequency channel for the modem.
***Only 1 index may be selected in a 1 modem system. "
DEFVAL { notActive }
::= { hzIduRadio1TxLowFreqEntry 5 }
hzIduRadio1ProgrammedFrequency OBJECT IDENTIFIER
::= { hzIduWirelessInterfaceRadio1Frequencies 5 }
hzIduRadio1ProgrammedFrequencyChannel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The channel that has been programmed for Radio 1."
::= { hzIduRadio1ProgrammedFrequency 1 }
hzIduRadio1ProgrammedFrequencyTxRf OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The programmed RF TX frequency in KHz."
::= { hzIduRadio1ProgrammedFrequency 2 }
hzIduRadio1ProgrammedFrequencyRxRf OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The RF RX frequency in KHz."
::= { hzIduRadio1ProgrammedFrequency 3 }
-- --------------------------------------
-- hzIduWirelessInterfaceRadio2Frequencies
-- --------------------------------------
hzIduRadio2Band OBJECT-TYPE
-- ------------Don't forget to update Radio1 Band list! ------------------
SYNTAX INTEGER { freqNone (1), fcc11-1-40 (2), fcc11-1-30 (3), fcc18-2-40 (4), fcc18-2-50(5), fcc23-3-50(6) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "The radio frequency standard used by Radio 2 (if present). Frequency bands are divided into sub bands.
i.e. FCC 23 Ghz Band is comprised of fcc23a, fcc23b, fcc23c and fcc23d which make up the entire FCC23 band"
DEFVAL { freqNone }
::= { hzIduWirelessInterfaceRadio2Frequencies 1 }
hzIduRadio2FreqGroupSelected OBJECT-TYPE
SYNTAX INTEGER { txLow ( 1 ) , txHigh ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "The frequency group selected for Radio 2.
The frequency subbands are divided into frequency groups txHigh and txLow. An horizon system must have one node configured to txLow and the other node configure to txHigh"
::= { hzIduWirelessInterfaceRadio2Frequencies 2 }
hzIduRadio2TxHighFreqTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduRadio2TxHighFreqEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table of txHigh frequency settings for Radio 2"
::= { hzIduWirelessInterfaceRadio2Frequencies 3 }
hzIduRadio2TxHighFreqEntry OBJECT-TYPE
SYNTAX HzIduRadio2TxHighFreqEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A txHighFrequency entry containing all the frequency values"
INDEX { hzIduRadio2TxHighFreqIndex }
::= { hzIduRadio2TxHighFreqTable 1 }
HzIduRadio2TxHighFreqEntry ::= SEQUENCE {
hzIduRadio2TxHighFreqIndex INTEGER,
hzIduRadio2TxHighFreqChannelIndex DisplayString,
hzIduRadio2TxHighFreqTransmitRfFrequency INTEGER,
hzIduRadio2TxHighFreqReceiveRfFrequency INTEGER,
hzIduRadio2TxHighFreqProgrammed INTEGER
}
hzIduRadio2TxHighFreqIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each frequency channel. "
::= { hzIduRadio2TxHighFreqEntry 1 }
hzIduRadio2TxHighFreqChannelIndex OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The channel index for the frequency."
::= { hzIduRadio2TxHighFreqEntry 2 }
hzIduRadio2TxHighFreqTransmitRfFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The RF TX frequency in KHz."
::= { hzIduRadio2TxHighFreqEntry 3 }
hzIduRadio2TxHighFreqReceiveRfFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The RF RX frequency in KHz."
::= { hzIduRadio2TxHighFreqEntry 4 }
hzIduRadio2TxHighFreqProgrammed OBJECT-TYPE
SYNTAX INTEGER { active ( 1 ) , notActive ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies the operating frequency channel for the modem.
***Only 1 index may be selected in a 1 modem system."
DEFVAL { notActive }
::= { hzIduRadio2TxHighFreqEntry 5 }
hzIduRadio2TxLowFreqTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduRadio2TxLowFreqEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table of txLow frequency settings for Radio 2"
::= { hzIduWirelessInterfaceRadio2Frequencies 4 }
hzIduRadio2TxLowFreqEntry OBJECT-TYPE
SYNTAX HzIduRadio2TxLowFreqEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A hzIduTxLowFrequeny entry containing the frequency values for a specific index"
INDEX { hzIduRadio2TxLowFreqIndex }
::= { hzIduRadio2TxLowFreqTable 1 }
HzIduRadio2TxLowFreqEntry ::= SEQUENCE {
hzIduRadio2TxLowFreqIndex INTEGER,
hzIduRadio2TxLowFreqChannelIndex DisplayString,
hzIduRadio2TxLowFreqTransmitRfFrequency INTEGER,
hzIduRadio2TxLowFreqReceiveRfFrequency INTEGER,
hzIduRadio2TxLowFreqProgrammed INTEGER
}
hzIduRadio2TxLowFreqIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each frequency channel. "
::= { hzIduRadio2TxLowFreqEntry 1 }
hzIduRadio2TxLowFreqChannelIndex OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The channel index for the frequency. "
::= { hzIduRadio2TxLowFreqEntry 2 }
hzIduRadio2TxLowFreqTransmitRfFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The RF TX frequency in KHz."
::= { hzIduRadio2TxLowFreqEntry 3 }
hzIduRadio2TxLowFreqReceiveRfFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The RF RX frequency in KHz."
::= { hzIduRadio2TxLowFreqEntry 4 }
hzIduRadio2TxLowFreqProgrammed OBJECT-TYPE
SYNTAX INTEGER { active ( 1 ) , notActive ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies the operating frequency channel for the modem.
***Only 1 index may be selected in a 1 modem system. "
DEFVAL { notActive }
::= { hzIduRadio2TxLowFreqEntry 5 }
hzIduRadio2ProgrammedFrequency OBJECT IDENTIFIER
::= { hzIduWirelessInterfaceRadio2Frequencies 5 }
hzIduRadio2ProgrammedFrequencyChannel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The channel that has been programmed for Radio 2."
::= { hzIduRadio2ProgrammedFrequency 1 }
hzIduRadio2ProgrammedFrequencyTxRf OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The programmed RF TX frequency in KHz."
::= { hzIduRadio2ProgrammedFrequency 2 }
hzIduRadio2ProgrammedFrequencyRxRf OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The RF RX frequency in KHz."
::= { hzIduRadio2ProgrammedFrequency 3 }
-- --------------------------------
-- hzIduWirelessInterfaceRedundancy
-- --------------------------------
hzIduWirelessInterfaceRedundancyActiveWirelessPort OBJECT-TYPE
SYNTAX INTEGER { wireless-port-1 (1), wireless-port-2 (2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute indicates the active wireless port and is only applicable when the system capacity has been configured to singleCarrier-redundancy."
::= { hzIduWirelessInterfaceRedundancy 1 }
hzIduWirelessInterfaceRedundancyPrimaryWirelessPort OBJECT-TYPE
SYNTAX INTEGER { wireless-port-1 (1), wireless-port-2 (2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "This attribute indicates the primary wireless port and is only applicable when the system capacity has been configured to singleCarrier-redundancy. The primary wireless port indicates which wireless port is connected to the 'primary' port on the RDRM coupler."
::= { hzIduWirelessInterfaceRedundancy 2 }
hzIduWirelessInterfaceRedundancySwitchingAlgorithm OBJECT-TYPE
SYNTAX INTEGER { manual ( 1 ), algorithm-based ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "This attribute selects the rule that will determine when a redundant path switch will take place. There are two options: manual and algorithm-based. The 'Manual' option turns off the automatic path switching feature. Only an operator can switch the active path."
::= { hzIduWirelessInterfaceRedundancy 3 }
hzIduWirelessInterfaceRedundancySwitchCause OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This string indicates the reason that a redundancy switch has occurred. If the active port is the primary port then this string is empty."
::= { hzIduWirelessInterfaceRedundancy 4 }
hzIduWirelessInterfaceRedundancySwitchRadio OBJECT-TYPE
SYNTAX INTEGER { switch ( 1 ) }
ACCESS write-only
STATUS mandatory
DESCRIPTION "This object switches the active path when switch (1) is written to this variable."
::= { hzIduWirelessInterfaceRedundancy 5 }
hzIduWirelessInterfaceRedundancyRemoveFaultyWirelessPort OBJECT-TYPE
SYNTAX INTEGER { wireless-port-1 (1), wireless-port-2 (2) }
ACCESS write-only
STATUS mandatory
DESCRIPTION "This object removes the specified port from the faulty port list."
::= { hzIduWirelessInterfaceRedundancy 6 }
hzIduWirelessInterfaceRedundancyDiagnostics OBJECT IDENTIFIER
::= { hzIduWirelessInterfaceRedundancy 7 }
-- ---------------------------------------------
-- hzIduWirelessInterfaceRedundancyDiagnostics
-- ---------------------------------------------
hzIduWirelessInterfaceRedundancyDiagnose OBJECT-TYPE
SYNTAX INTEGER { diagnose ( 1 ) }
ACCESS write-only
STATUS mandatory
DESCRIPTION "This write-only object will diagnose problems with switching paths. Write diagnose (1) to this object and check results in hzIduWirelessInterfaceRedundancyDiagnosticResult object"
::= { hzIduWirelessInterfaceRedundancyDiagnostics 1 }
hzIduWirelessInterfaceRedundancyDiagnosticResult OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "The result from Redundancy Diagnostic is read from this object. Note that the diagnostic result presented in this object is private to SNMP initiated diagnostics. If a diagnostic is initiated from the CLI or WEB, this result will remain unchanged."
::= { hzIduWirelessInterfaceRedundancyDiagnostics 2 }
-- ----------------------------
-- hzIduWirelessInterfaceAntenna
-- ----------------------------
hzIduAntennaDiameter OBJECT-TYPE
SYNTAX INTEGER { antenna12 ( 1 ), antenna24 ( 2 ), antenna36 ( 3 ), antenna48 ( 4 ), antenna72 ( 5 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "This defines the diameter of the antenna represented in inches."
::= { hzIduWirelessInterfaceAntenna 1 }
--
-- hzIduCalendar
--
hzIduDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "A string in the format as follows:
XX/YY/ZZ
Where XX = day of month (range 01 to 31)
YY = month of year(range 01 to 12)
ZZ = year (range 01 - 99)"
::= { hzIduCalendar 1 }
hzIduTime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "A string in the format as follows:
aa:bb:cc.ddd
Where aa = hour of day ( range 00 to 23 )
bb = minute of hour ( range 00 to 59 )
cc = second of minute( range 00 to 59 )
ddd = thousandths of second (range 000 to 999)"
::= { hzIduCalendar 2 }
--
-- ALARM FOLDER
--
hzIduClearAlarmCounters OBJECT-TYPE
SYNTAX INTEGER { nicCounters ( 1 ) , modemCounters ( 2 ) , radioCounters ( 3 ) , allCounters ( 4 ), otherCounters (5) }
ACCESS write-only
STATUS mandatory
DESCRIPTION "Clears the alarm counters for the specified group"
::= { hzIduAlarms 1 }
hzIduSystemAlarms OBJECT IDENTIFIER
::= { hzIduAlarms 2 }
hzIduNetworkInterfaceAlarms OBJECT IDENTIFIER
::= { hzIduAlarms 3 }
hzIduEnetPort1Alarms OBJECT IDENTIFIER
::= { hzIduNetworkInterfaceAlarms 1 }
hzIduEnetPort2Alarms OBJECT IDENTIFIER
::= { hzIduNetworkInterfaceAlarms 2 }
hzIduWirelessInterfaceAlarms OBJECT IDENTIFIER
::= { hzIduAlarms 4 }
hzIduModemAlarms OBJECT IDENTIFIER
::= { hzIduWirelessInterfaceAlarms 1 }
hzIduRadioAlarms OBJECT IDENTIFIER
::= { hzIduWirelessInterfaceAlarms 2 }
--
-- System Alarms
--
hzIduExplicitAuthenticationFailure OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Authentication of the peer horizon node has failed. The severity is critical, the probable cause is an incorrect authentication configuration on horizon faulty cable between the modem and radio, and recommended course of action is to check both ends of the link."
::= { hzIduSystemAlarms 1 }
hzIduExplicitAuthenticationFailureCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the number of times explicit authentication has failed."
::= { hzIduSystemAlarms 2 }
hzIduAamConfigMismatch OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "In the near end Automatic Adaptive Modulation(AAM) feature set to on and in peer it is set to off"
::= { hzIduSystemAlarms 3 }
hzIduAamConfigMismatchCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds AAMConfigMismatch alarm has been active."
::= { hzIduSystemAlarms 4 }
hzIduAamActive OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates aam is active and system running on lowest modulation"
::= { hzIduSystemAlarms 5 }
hzIduAamActiveCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds AAMActive alarm has been active."
::= { hzIduSystemAlarms 6 }
hzIduSntpServerUnavailableAlarm OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "All of the SNTP servers are not available. "
::= { hzIduSystemAlarms 7 }
hzIduSntpServerUnavailableAlarmCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates how long in seconds all of the SNTP servers are not available."
::= { hzIduSystemAlarms 8 }
hzIduFrequencyFileInvalid OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Executing frequency file is invalid."
::= { hzIduSystemAlarms 9 }
hzIduFrequencyFileInvalidCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the time (in secs) since this alarm exist."
::= { hzIduSystemAlarms 10 }
hzIduFan1Failure OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates that Fan 1 has failed."
::= { hzIduSystemAlarms 11 }
hzIduFan1FailureCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the number of seconds that the fan has failed for."
::= { hzIduSystemAlarms 12 }
hzIduFan2Failure OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates that Fan 2 has failed."
::= { hzIduSystemAlarms 13 }
hzIduFan2FailureCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the number of seconds that the fan has failed for."
::= { hzIduSystemAlarms 14 }
hzIduFan3Failure OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates that Fan 3 has failed."
::= { hzIduSystemAlarms 15 }
hzIduFan3FailureCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the number of seconds that the fan has failed for."
::= { hzIduSystemAlarms 16 }
hzIduFan4Failure OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates that Fan 4 has failed."
::= { hzIduSystemAlarms 17 }
hzIduFan4FailureCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the number of seconds that the fan has failed for."
::= { hzIduSystemAlarms 18 }
hzIduPrimaryPortNotSet OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The primary port used for redundancy has not been set."
::= { hzIduSystemAlarms 19 }
hzIduPrimaryPortNotSetCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduSystemAlarms 20 }
hzIduSecondaryPortActive OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The active wireless port has switched to the secondary wireless port."
::= { hzIduSystemAlarms 21 }
hzIduSecondaryPortActiveCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduSystemAlarms 22 }
hzIduPrimaryPortFaulty OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The primary wireless port is faulty."
::= { hzIduSystemAlarms 23 }
hzIduPrimaryPortFaultyCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduSystemAlarms 24 }
hzIduSecondaryPortFaulty OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The secondary wireless port is faulty."
::= { hzIduSystemAlarms 25 }
hzIduSecondaryPortFaultyCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduSystemAlarms 26 }
--
-- NETWORK INTERFACE PORT1 ALARMS
--
hzIduEnetPort1DroppedEnetFramesThresholdExceeded OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The threshold for number of frames dropped has been exceeded. The threshold and the number of seconds that it must exceed this threshold are programmed by the user."
::= { hzIduEnetPort1Alarms 1 }
hzIduEnetPort1DroppedEnetFramesThresholdCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate time, in seconds, that this alarm has been in the active state"
::= { hzIduEnetPort1Alarms 2 }
hzIduEnetPort1BandwidthUtilizationThresholdExceeded OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The threshold for the percentage of available bandwidth has been exceeded. The threshold and the number of seconds that it must exceed this threshold are programmed by the user."
::= { hzIduEnetPort1Alarms 3 }
hzIduEnetPort1BandwidthUtilizationThresholdCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate time, in seconds, that this alarm has been in the active state"
::= { hzIduEnetPort1Alarms 4 }
hzIduEnetPort1RlsMismatch OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "RLS configurations on the pair of systems are mismatched."
::= { hzIduEnetPort1Alarms 5 }
hzIduEnetPort1RlsMismatchCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate time, in seconds, that this alarm has been in the active state"
::= { hzIduEnetPort1Alarms 6 }
hzIduRLSQueueBasedShutdownActivated OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "RLS Queue-Based shutdown is activated."
::= { hzIduEnetPort1Alarms 7 }
hzIduRLSQueueBasedShutdownActivatedCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate time, in seconds, that this alarm has been in the active state"
::= { hzIduEnetPort1Alarms 8 }
hzIduEnetPort1EthernetLinkDown OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates whether the Ethernet link is down or not. The severity is major, the probable cause is an incorrect configuration of the switch or router connected to horizon. The recommended course of action is to check the connection."
::= { hzIduEnetPort1Alarms 9 }
hzIduEnetPort1EthernetLinkDownActivatedCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate time, in seconds, that this alarm has been in the active state"
::= { hzIduEnetPort1Alarms 10 }
--
-- NETWORK INTERFACE Port2 ALARMS
--
hzIduEnetPort2EthernetLinkDown OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates whether the Ethernet link is down or not. The severity is major, the probable cause is an incorrect configuration of the switch or router connected to horizon. The recommended course of action is to check the connection."
::= { hzIduEnetPort2Alarms 1 }
hzIduEnetPort2EthernetLinkDownActivatedCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate time, in seconds, that this alarm has been in the active state"
::= { hzIduEnetPort2Alarms 2 }
--
-- MODEM ALARMS
--
hzIduModemAlarmsTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduModemAlarmsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table of Modem Alarms."
::= { hzIduModemAlarms 1 }
hzIduModemAlarmsEntry OBJECT-TYPE
SYNTAX HzIduModemAlarmsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Modem Alarms"
INDEX { hzIduModemAlarmsIndex }
::= { hzIduModemAlarmsTable 1 }
HzIduModemAlarmsEntry ::= SEQUENCE {
hzIduModemAlarmsIndex INTEGER,
hzIduModemRxLossOfSignal INTEGER,
hzIduModemRxLossOfSignalCounts Counter,
hzIduModemTxLossOfSync INTEGER,
hzIduModemTxLossOfSyncCounts Counter,
hzIduModemSnrBelowThreshold INTEGER,
hzIduModemSnrBelowThresholdCounts Counter,
hzIduModemEqualizerStressExceedThreshold INTEGER,
hzIduModemEquilizerStressExceedThresholdCounts Counter,
hzIduModemHardwareFault INTEGER,
hzIduModemHardwareFaultCounts Counter,
hzIduModemProgrammingError INTEGER,
hzIduModemProgrammingErrorCounts Counter,
hzIduRLSShutdownActivated INTEGER,
hzIduRLSShutdownActivatedCounts Counter
}
hzIduModemAlarmsIndex OBJECT-TYPE
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each interface. "
::= { hzIduModemAlarmsEntry 1 }
hzIduModemRxLossOfSignal OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Loss of signal lock from the demodulator. The severity is critical, the probable cause is lost synchronization with the far end, and recommended course of action is to check the operational state of both ends of the link."
::= { hzIduModemAlarmsEntry 2 }
hzIduModemRxLossOfSignalCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduModemAlarmsEntry 3 }
hzIduModemTxLossOfSync OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Loss of sync bytes at the input of the modulator. The severity is critical, the probable cause is physical interference in the air link, and recommended course of action is to check the line of site between the horizon nodes."
::= { hzIduModemAlarmsEntry 4 }
hzIduModemTxLossOfSyncCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduModemAlarmsEntry 5 }
hzIduModemSnrBelowThreshold OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The demodulator SNR performance worse than programmed levels. The severity is major, the probable cause is physical interference in the air link path or misalignment of the radios or severe weather conditions, and recommended course of action is to check the line of site between the horizon nodes."
::= { hzIduModemAlarmsEntry 6 }
hzIduModemSnrBelowThresholdCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduModemAlarmsEntry 7 }
hzIduModemEqualizerStressExceedThreshold OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Equalizer Stress measured within the demodulator exceeds the threshold value."
::= { hzIduModemAlarmsEntry 8 }
hzIduModemEquilizerStressExceedThresholdCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduModemAlarmsEntry 9 }
hzIduModemHardwareFault OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { hzIduModemAlarmsEntry 10 }
hzIduModemHardwareFaultCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduModemAlarmsEntry 11 }
hzIduModemProgrammingError OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Encountered some problem while programming the modem."
::= { hzIduModemAlarmsEntry 12 }
hzIduModemProgrammingErrorCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduModemAlarmsEntry 13 }
hzIduRLSShutdownActivated OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "RLS shutdown is activated."
::= { hzIduModemAlarmsEntry 14 }
hzIduRLSShutdownActivatedCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate time, in seconds, that this alarm has been in the active state"
::= { hzIduModemAlarmsEntry 15 }
--
-- RADIO ALARMS
--
hzIduRadioAlarmsTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduRadioAlarmsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table of Radio Alarms."
::= { hzIduRadioAlarms 1 }
hzIduRadioAlarmsEntry OBJECT-TYPE
SYNTAX HzIduRadioAlarmsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Radio Alarms"
INDEX { hzIduRadioAlarmsIndex }
::= { hzIduRadioAlarmsTable 1 }
HzIduRadioAlarmsEntry ::= SEQUENCE {
hzIduRadioAlarmsIndex INTEGER,
hzIduRadioPLDROLostLock INTEGER,
hzIduRadioPLDROLostLockCounts Counter,
hzIduRadioLostCommunication INTEGER,
hzIduRadioLostCommunicationCounts Counter,
hzIduRadioMismatch INTEGER,
hzIduRadioMismatchCounts Counter,
hzIduRadioPowerAmp INTEGER,
hzIduRadioPowerAmpCounts Counter,
hzIduRadioExcessiveTxCableLoss INTEGER,
hzIduRadioExcessiveTxCableLossCounts Counter,
hzIduRadioRslBelowThreshold INTEGER,
hzIduRadioRslBelowThresholdCounts Counter,
hzIduRadioHighPowerOptionM1 INTEGER,
hzIduRadioHighPowerOptionM1Counts Counter,
hzIduRadioHighPowerOptionM2 INTEGER,
hzIduRadioHighPowerOptionM2Counts Counter,
hzIduRadioHighPowerTxDetector INTEGER,
hzIduRadioHighPowerTxDetectorCounts Counter,
hzIduRadioAtpcConfigMismatch INTEGER,
hzIduRadioAtpcConfigMismatchCounts Counter,
hzIduRadioRedundancySerialNumMismatch INTEGER,
hzIduRadioRedundancySerialNumMismatchCounts Counter,
hzIduRadioExcessiveTxCableLossChange INTEGER,
hzIduRadioExcessiveTxCableLossChangeCounts Counter,
hzIduRadioExcessiveRxCableLoss INTEGER,
hzIduRadioExcessiveRxCableLossCounts Counter,
hzIduRadioAtpcTxAtMaxPower INTEGER,
hzIduRadioAtpcTxAtMaxPowerCounts Counter
}
hzIduRadioAlarmsIndex OBJECT-TYPE
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each radio interface. "
::= { hzIduRadioAlarmsEntry 1 }
hzIduRadioPLDROLostLock OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The PLDRO/LO has lost lock on the radio. The severity is critical, the probable cause a faulty radio unit and recommended course of action is to replace the radio unit."
::= { hzIduRadioAlarmsEntry 2 }
hzIduRadioPLDROLostLockCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduRadioAlarmsEntry 3 }
hzIduRadioLostCommunication OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "RS232 communication lost between IDU and the radio. The severity is critical, the probable cause is a faulty cable between the modem and radio, and recommended course of action is to check the connection."
::= { hzIduRadioAlarmsEntry 4 }
hzIduRadioLostCommunicationCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduRadioAlarmsEntry 5 }
hzIduRadioMismatch OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The radio connected to the IDU modem does not match the frequency programmed into the modem unit. The severity is major, the probable cause is an incorrectly programmed modem or an incorrect radio type connected to the modem, and recommended course of action is to check the modem frequency settings and radio hardware version number or serial number."
::= { hzIduRadioAlarmsEntry 6 }
hzIduRadioMismatchCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduRadioAlarmsEntry 7 }
hzIduRadioPowerAmp OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The power amplifier on the radio is not operating within normal operating specifications. The severity is critical, the probable cause a faulty radio unit, and recommended course of action is to replace the radio unit."
::= { hzIduRadioAlarmsEntry 8 }
hzIduRadioPowerAmpCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduRadioAlarmsEntry 9 }
hzIduRadioExcessiveTxCableLoss OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION ""
::= { hzIduRadioAlarmsEntry 10 }
hzIduRadioExcessiveTxCableLossCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduRadioAlarmsEntry 11 }
hzIduRadioRslBelowThreshold OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The minimum radio receive signal level threshold has been crossed. The severity is major, the probable cause is physical interference in the air link path or misalignment of the radios or severe weather conditions, and recommended course of action is to check the line of site between the air pair nodes."
::= { hzIduRadioAlarmsEntry 12 }
hzIduRadioRslBelowThresholdCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduRadioAlarmsEntry 13 }
hzIduRadioHighPowerOptionM1 OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "This applies to High Power Radios only. Indicates Power Amp Alarm (M1)."
::= { hzIduRadioAlarmsEntry 14 }
hzIduRadioHighPowerOptionM1Counts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduRadioAlarmsEntry 15 }
hzIduRadioHighPowerOptionM2 OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "This applies to High Power Radios only. Indicates Power Amp Alarm (M2)."
::= { hzIduRadioAlarmsEntry 16 }
hzIduRadioHighPowerOptionM2Counts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduRadioAlarmsEntry 17 }
hzIduRadioHighPowerTxDetector OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "This applies to High Power Radios only. Indicates minimum power threshold has not been surpassed."
::= { hzIduRadioAlarmsEntry 18 }
hzIduRadioHighPowerTxDetectorCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduRadioAlarmsEntry 19 }
hzIduRadioAtpcConfigMismatch OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The pair of the systems don't have same ATPC configurations. On one side ATPC is enabled, but on the other side ATPC is not enabled. "
::= { hzIduRadioAlarmsEntry 20 }
hzIduRadioAtpcConfigMismatchCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduRadioAlarmsEntry 21 }
hzIduRadioRedundancySerialNumMismatch OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The radio serial number programmed in flash and radio do not match."
::= { hzIduRadioAlarmsEntry 22 }
hzIduRadioRedundancySerialNumMismatchCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduRadioAlarmsEntry 23 }
hzIduRadioExcessiveTxCableLossChange OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Cable loss change exceeds the threshold."
::= { hzIduRadioAlarmsEntry 24 }
hzIduRadioExcessiveTxCableLossChangeCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduRadioAlarmsEntry 25 }
hzIduRadioExcessiveRxCableLoss OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Rx gain can not be adjusted to desired value."
::= { hzIduRadioAlarmsEntry 26 }
hzIduRadioExcessiveRxCableLossCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduRadioAlarmsEntry 27 }
hzIduRadioAtpcTxAtMaxPower OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "ATPC auto-disabled (transmitting at coordinated power)."
::= { hzIduRadioAlarmsEntry 28 }
hzIduRadioAtpcTxAtMaxPowerCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates the approximate number of seconds that this alarm has been active."
::= { hzIduRadioAlarmsEntry 29 }
--
-- TRAP INFORMATION HOSTS, ENABLE/DISABLE
--
hzIduSnmpTrapHostTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduSnmpTrapHostEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Table containing SNMP trap host entries."
::= { hzIduTrapConfig 1 }
hzIduSnmpTrapHostEntry OBJECT-TYPE
SYNTAX HzIduSnmpTrapHostEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "The snmp trap host entry containing all the trap host information"
INDEX { hzIduSnmpTrapHostIndex }
::= { hzIduSnmpTrapHostTable 1 }
HzIduSnmpTrapHostEntry ::= SEQUENCE {
hzIduSnmpTrapHostIndex INTEGER,
hzIduSnmpTrapHostMode INTEGER,
hzIduSnmpTrapHostIpAddress IpAddress,
hzIduSnmpTrapHostCommunityName DisplayString,
hzIduSnmpTrapHostActivated INTEGER
}
hzIduSnmpTrapHostIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each trap host. "
::= { hzIduSnmpTrapHostEntry 1 }
hzIduSnmpTrapHostMode OBJECT-TYPE
SYNTAX INTEGER { static ( 1 ) , dns ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates how the snmp trap host is obtained for the system."
DEFVAL { static }
::= { hzIduSnmpTrapHostEntry 2 }
hzIduSnmpTrapHostIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates snmp trap host IP address. "
::= { hzIduSnmpTrapHostEntry 3 }
hzIduSnmpTrapHostCommunityName OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
ACCESS read-only
STATUS mandatory
DESCRIPTION "The community string name used in Traps."
::= { hzIduSnmpTrapHostEntry 4 }
hzIduSnmpTrapHostActivated OBJECT-TYPE
SYNTAX INTEGER { notActive ( 1 ) , active ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Specifies whether traps are to be sent to this specific host or not"
DEFVAL { notActive }
::= { hzIduSnmpTrapHostEntry 5 }
--
-- SNMP V3 TRAP HOST TABLE
--
hzIduSnmpV3TrapHostsTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduSnmpV3TrapHostsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Table containing snmp V3 trap host entries"
::= { hzIduTrapConfig 2 }
hzIduSnmpV3TrapHostsEntry OBJECT-TYPE
SYNTAX HzIduSnmpV3TrapHostsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Contains the snmp v3 trap host information"
INDEX { hzIduSnmpV3TrapHostsIndex }
::= { hzIduSnmpV3TrapHostsTable 1 }
HzIduSnmpV3TrapHostsEntry ::= SEQUENCE {
hzIduSnmpV3TrapHostsIndex INTEGER,
snmpV3TrapHostIpAddress IpAddress,
snmpV3TrapHostUserName DisplayString,
snmpV3TrapHostAuthProtocol INTEGER,
snmpV3TrapHostAuthPassword DisplayString,
snmpV3TrapHostPrivProtocol INTEGER,
snmpV3TrapHostPrivPassword DisplayString,
snmpV3TrapHostActivated INTEGER
}
hzIduSnmpV3TrapHostsIndex OBJECT-TYPE
SYNTAX INTEGER (0..4)
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each v3 trap host."
::= { hzIduSnmpV3TrapHostsEntry 1 }
snmpV3TrapHostIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates snmp trap host IP address. "
::= { hzIduSnmpV3TrapHostsEntry 2 }
snmpV3TrapHostUserName OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
ACCESS read-only
STATUS mandatory
DESCRIPTION "The user name of the v3 trap host."
::= { hzIduSnmpV3TrapHostsEntry 3 }
snmpV3TrapHostAuthProtocol OBJECT-TYPE
SYNTAX INTEGER { noAuth ( 1 ) , md5 ( 2 ), sha(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The authentication alogorithm used by the v3 trap host."
::= { hzIduSnmpV3TrapHostsEntry 4 }
snmpV3TrapHostAuthPassword OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
ACCESS read-only
STATUS mandatory
DESCRIPTION "The authentication password of the v3 trap host."
::= { hzIduSnmpV3TrapHostsEntry 5 }
snmpV3TrapHostPrivProtocol OBJECT-TYPE
SYNTAX INTEGER { noPriv ( 1 ) , des ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The privacy encryption alogorithm used by the v3 trap host."
::= { hzIduSnmpV3TrapHostsEntry 6 }
snmpV3TrapHostPrivPassword OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
ACCESS read-only
STATUS mandatory
DESCRIPTION "The privacy password of the v3 trap host."
::= { hzIduSnmpV3TrapHostsEntry 7 }
snmpV3TrapHostActivated OBJECT-TYPE
SYNTAX INTEGER { notActive ( 1 ) , active ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Specifies whether a specific v3 trap host is allowed to access the system"
DEFVAL { notActive }
::= { hzIduSnmpV3TrapHostsEntry 8 }
-- ----------------------------
-- TRAP ENABLE
-- ----------------------------
hzIduTrapEnable OBJECT IDENTIFIER
::= { hzIduTrapConfig 3 }
hzIduColdStartTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 1 }
hzIduLinkDownTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 2 }
hzIduLinkUpTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 3 }
hzIduExplicitAuthenticationFailureTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 4 }
hzIduAamConfigMismatchTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Enables or disables the aamConfigMismatch trap. "
DEFVAL { disabled }
::= { hzIduTrapEnable 5 }
hzIduAamActiveTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Enables or disables the aamActive trap. "
DEFVAL { disabled }
::= { hzIduTrapEnable 6 }
hzIduAtpcConfigMismatchTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Enables or disables the trap. "
DEFVAL { disabled }
::= { hzIduTrapEnable 7 }
hzIduSntpServersUnreachableTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Enables or disables the trap. "
DEFVAL { disabled }
::= { hzIduTrapEnable 8 }
hzIduFrequencyFileInvalidTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Enables or disables the trap. "
DEFVAL { disabled }
::= { hzIduTrapEnable 9 }
hzIduEnetPortDroppedFramesThresholdExceedTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Enables or disables the trap."
DEFVAL { disabled }
::= { hzIduTrapEnable 10 }
hzIduEnetPortBandwidthUtilizationThresholdExceedTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Enables or disables the trap."
DEFVAL { disabled }
::= { hzIduTrapEnable 11 }
hzIduEnetPortRlsMismatchTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Enables or disables the trap. "
DEFVAL { disabled }
::= { hzIduTrapEnable 12 }
hzIduRLSQueueBasedShutdownActivatedTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Enables or disables the Queue-Based RLS Shutdown trap. "
DEFVAL { disabled }
::= { hzIduTrapEnable 13 }
hzIduModemRxLossOfSignalLockTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 14 }
hzIduModemTxLossOfSyncTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 15 }
hzIduModemSnrBelowThresholdTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 16 }
hzIduModemEqualizerStressExceedThresholdTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 17 }
hzIduModemChannelizedRslBelowThresholdTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Enables or disables the trap."
DEFVAL { disabled }
::= { hzIduTrapEnable 18 }
hzIduModemHardwareFaultTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 19 }
hzIduModemProgrammingErrorTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 20 }
hzIduTtyManagementSessionCommencedTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 21 }
hzIduTtyManagementSessionTerminatedTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 22 }
hzIduAtpcTxAtMaxPwrTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 23 }
hzIduRadioPLDROLostLockTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 24 }
hzIduRadioLostCommunicationTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 25 }
hzIduRadioMismatchTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 26 }
hzIduRadioPowerAmpTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 27 }
hzIduRadioExcessiveTxCableLossTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 28 }
hzIduHiPowerRadioDrainM1Trap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 29 }
hzIduHiPowerRadioDrainM2Trap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 30 }
hzIduHiPowerRadioTxDetectorTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 31 }
hzIduSecondaryRadioIsActiveTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 32 }
hzIduRedundancySerialNumberMisMatchTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 33 }
hzIduRadioFirmwareMismatchTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 34 }
hzIduSecondaryRadioNotdetectedTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 35 }
hzIduPrimaryRadioNotdetectedTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 36 }
hzIduFaultyPrimaryRadioTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 37 }
hzIduRadioExcessiveTxCableLossChangeTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 38 }
hzIduRadioExcessiveRxCableLossTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 39 }
hzIduRedundancyPrimaryPortNotSetTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 40 }
hzIduRedundancySecondaryPortIsActiveTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 41 }
hzIduRedundancyPrimaryPortFaultyTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 42 }
hzIduRedundancySecondaryPortFaultyTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 43 }
hzIduFan1FailedTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 44 }
hzIduFan2FailedTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 45 }
hzIduFan3FailedTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 46 }
hzIduFan4FailedTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether this trap is to be sent or not. "
DEFVAL { disabled }
::= { hzIduTrapEnable 47 }
hzIduPortRLSShutdownActivatedTrap OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Enables or disables the RLS Shutdown trap. "
DEFVAL { disabled }
::= { hzIduTrapEnable 48 }
--
-- SNMP MANAGERS
--
hzIduSnmpUserAccess OBJECT-TYPE
SYNTAX INTEGER { explicitManagers ( 1 ) , any ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Specifies the user access to the system. If access is set to 'explicitManagers' then only managers with ip addresses set in snmpManagersTable will be able to gain SNMP access to the system. If access is set to 'any' then any manager will be able to gain SNMP access to the system"
::= { hzIduSnmp 1 }
hzIduSnmpManagerAnyCommunityName OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
ACCESS read-only
STATUS mandatory
DESCRIPTION "The community string name used by the 'any' manager."
::= { hzIduSnmp 2 }
hzIduSnmpSetRequests OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Indicates whether SNMP SET requests are allowed."
DEFVAL { disabled }
::= { hzIduSnmp 3 }
hzIduSnmpManagersTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduSnmpManagersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Table containing snmp manager entries"
::= { hzIduSnmp 4 }
hzIduSnmpManagersEntry OBJECT-TYPE
SYNTAX HzIduSnmpManagersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Contains the snmp manager information"
INDEX { hzIduSnmpManagersIndex }
::= { hzIduSnmpManagersTable 1 }
HzIduSnmpManagersEntry ::= SEQUENCE {
hzIduSnmpManagersIndex INTEGER,
hzIduSnmpManagerIpAddress IpAddress,
hzIduSnmpManagerCommunityName DisplayString,
hzIduSnmpManagerActivated INTEGER
}
hzIduSnmpManagersIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each manager."
::= { hzIduSnmpManagersEntry 1 }
hzIduSnmpManagerIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION "The IP address of the Manager."
::= { hzIduSnmpManagersEntry 2 }
hzIduSnmpManagerCommunityName OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
ACCESS read-only
STATUS mandatory
DESCRIPTION "The community string name used by the manager."
::= { hzIduSnmpManagersEntry 3 }
hzIduSnmpManagerActivated OBJECT-TYPE
SYNTAX INTEGER { notActive ( 1 ) , active ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Specifies whether a specific manager is allowed to access the system"
DEFVAL { notActive }
::= { hzIduSnmpManagersEntry 4 }
hzIduSnmpV3ManagersTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduSnmpV3ManagersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Table containing snmp V3 manager entries"
::= { hzIduSnmp 5 }
hzIduSnmpV3ManagersEntry OBJECT-TYPE
SYNTAX HzIduSnmpV3ManagersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Contains the snmp v3 manager information"
INDEX { hzIduSnmpV3ManagersIndex }
::= { hzIduSnmpV3ManagersTable 1 }
HzIduSnmpV3ManagersEntry ::= SEQUENCE {
hzIduSnmpV3ManagersIndex INTEGER,
hzIduSnmpV3ManagerUserName DisplayString,
hzIduSnmpV3ManagerAuthProtocol INTEGER,
hzIduSnmpV3ManagerAuthPassword DisplayString,
hzIduSnmpV3ManagerPrivProtocol INTEGER,
hzIduSnmpV3ManagerPrivPassword DisplayString,
hzIduSnmpV3ManagerActivated INTEGER
}
hzIduSnmpV3ManagersIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each v3 manager."
::= { hzIduSnmpV3ManagersEntry 1 }
hzIduSnmpV3ManagerUserName OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
ACCESS read-only
STATUS mandatory
DESCRIPTION "The user name of the v3 Manager."
::= { hzIduSnmpV3ManagersEntry 2 }
hzIduSnmpV3ManagerAuthProtocol OBJECT-TYPE
SYNTAX INTEGER { noAuth ( 1 ) , md5 ( 2 ), sha(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The authentication alogorithm used by the v3 manager."
::= { hzIduSnmpV3ManagersEntry 3 }
hzIduSnmpV3ManagerAuthPassword OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
ACCESS read-only
STATUS mandatory
DESCRIPTION "The authentication password of the v3 Manager."
::= { hzIduSnmpV3ManagersEntry 4 }
hzIduSnmpV3ManagerPrivProtocol OBJECT-TYPE
SYNTAX INTEGER { noPriv ( 1 ) , des ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The privacy encryption alogorithm used by the v3 manager."
::= { hzIduSnmpV3ManagersEntry 5 }
hzIduSnmpV3ManagerPrivPassword OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
ACCESS read-only
STATUS mandatory
DESCRIPTION "The privacy password of the v3 Manager."
::= { hzIduSnmpV3ManagersEntry 6 }
hzIduSnmpV3ManagerActivated OBJECT-TYPE
SYNTAX INTEGER { notActive ( 1 ) , active ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "Specifies whether a specific v3 manager is allowed to access the system"
DEFVAL { notActive }
::= { hzIduSnmpV3ManagersEntry 7 }
-- ------------------------------
-- hzIduManagementSessions
-- ------------------------------
hzIduTtySessionUserTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduTtySessionUserEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table of Wireless Interface Radios"
::= { hzIduManagementSessions 1 }
hzIduTtySessionUserEntry OBJECT-TYPE
SYNTAX HzIduTtySessionUserEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A Wireless Interface Radio"
INDEX { hzIduTtySessionUserIndex }
::= { hzIduTtySessionUserTable 1 }
HzIduTtySessionUserEntry ::= SEQUENCE {
hzIduTtySessionUserIndex INTEGER,
hzIduTtySessionUserName DisplayString,
hzIduTtySessionUserConnectionType INTEGER,
hzIduTtySessionUserState INTEGER
}
hzIduTtySessionUserIndex OBJECT-TYPE
SYNTAX INTEGER { user1 ( 1 ), user2 ( 2 ), user3 ( 3 ), user4 ( 4 ), user5 ( 5 ), user6 ( 6 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each user."
::= { hzIduTtySessionUserEntry 1 }
hzIduTtySessionUserName OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 32 ) )
ACCESS read-only
STATUS mandatory
DESCRIPTION "The username of a management session using Telnet or HTTP. The session state variable must be checked to determine if the management session is currently in progress."
::= { hzIduTtySessionUserEntry 2 }
hzIduTtySessionUserConnectionType OBJECT-TYPE
SYNTAX INTEGER { informationNotAvailable ( 1 ) , serialPort ( 2 ) , enetPort2 ( 3 ) , enetPort1 ( 4 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The physical port used to log in to the system. The serial port is always local to the equipment. The 10BaseT connector may be local, or remote, depending on if the configuration of network management port. The inband connection is the port carrying customer traffic."
::= { hzIduTtySessionUserEntry 3 }
hzIduTtySessionUserState OBJECT-TYPE
SYNTAX INTEGER { informationNotAvailable ( 1 ) , sessionTerminated ( 2 ) , sessionInProgress ( 3 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The state of the session. The session is inProgress if the user is currently logged into the system. The session is terminated if the user has logged out of the system."
::= { hzIduTtySessionUserEntry 4 }
--
-- HTTPS group
--
hzIduHttpEnable OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Indicates whether HTTP is enabled."
DEFVAL { disabled }
::= { hzIduHttp 1 }
hzIduHttpSecure OBJECT IDENTIFIER
::= { hzIduHttp 2 }
hzIduHttpSecureCertificateStatus OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 100 ) )
ACCESS read-only
STATUS mandatory
DESCRIPTION "Returns the HTTPS certificate status"
::= { hzIduHttpSecure 1 }
hzIduHttpSecureAccessForAdminUsers OBJECT-TYPE
SYNTAX INTEGER { off( 1 ), on ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "the HTTPS access requirement for Admin user group."
::= { hzIduHttpSecure 2 }
hzIduHttpSecureAccessForNocUsers OBJECT-TYPE
SYNTAX INTEGER { off( 1 ), on ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "the HTTPS access requirement for Noc user group."
::= { hzIduHttpSecure 3 }
hzIduHttpSecureAccessForSuperUsers OBJECT-TYPE
SYNTAX INTEGER { off( 1 ), on ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "the HTTPS access requirement for Super user group."
::= { hzIduHttpSecure 4 }
--
-- Giga Ethernet Qos
--
hzIduQosEnable OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Indicates whether QOS is enabled."
DEFVAL { disabled }
::= { hzIduQos 1 }
hzIduCosType OBJECT-TYPE
SYNTAX INTEGER { cosVlan ( 1 ) , cosQinQiTag ( 2 ), cosQinQoTag ( 3 )}
ACCESS read-write
STATUS mandatory
DESCRIPTION "Indicates the class of service tag type. Based on the setting Horizon will use the CoS value in the VLAN tag, or Q-in-Q inner VLAN tag, or Q-in-Q outer VLAN tag."
DEFVAL { cosVlan }
::= { hzIduQos 2 }
--
-- 802.1p priorities assignment.
--
hzIduCoSQinQiTag OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Sets the value of the Q-in-Q inner tag. This tag is also used to classify the non-Q-in-Q VLAN. Default value is 0x8100."
DEFVAL { 0 }
::= { hzIduQos 3 }
hzIduCoSQinQoTag OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Sets the value of the Q-in-Q outer VLAN tag. Default value is 0x8100."
DEFVAL { 0 }
::= { hzIduQos 4 }
hzIduCosQueueMapping OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 15 .. 32 ) )
ACCESS read-write
STATUS mandatory
DESCRIPTION "User queue assignments for CoS values 0 to 7.
There are 4 coS queues. Their corresponding
queue numbers are 1,2, 3, where 1 is the lowest priority queue and
4 is the highest priority queue.
CoS to queue mapping example: 1 1 2 2 3 3 4 4."
::= { hzIduQos 5 }
--
-- Queue operation mode
--
hzIduCosExpediteQueue OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ), enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "This sets the user queue operation mode. (a) In expedite mode,
any Queue can be assigned 100% of CIR. Queue 4 is serviced first
and queue 1 is servcied last.(b) In non expedite mode, the sum of all CIRs
must be equal to 100%. In this mode higher priority queues
will be serviced first until that queue is emptied or
the defined CIR is reached."
DEFVAL { 1 }
::= { hzIduQos 6 }
--
-- user queues configuration.
--
hzIduCosQueueCIR OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 32 ) )
ACCESS read-write
STATUS mandatory
DESCRIPTION "Committed Information Rate (CIR) assignments for CoS queues
1 to 4. CIR is assigned as the percentage of system current speed.
When expedite queue is enabled any queue can be assigned 100% bandwidth.
When expedite queue is disabled the sum of CIR of all queues should be 100."
::= { hzIduQos 7 }
hzIduCosQueueCBS OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 32 ) )
ACCESS read-write
STATUS mandatory
DESCRIPTION "Comitted Burst Size (CBS) for CoS queues 1 to 4. CBS is the percentage
of total packet buffer size. The sum of CBS's of all 4
queues must be equal to 100. Minimum CBS assignable to any queue
is 1."
::= { hzIduQos 8 }
hzIduCosDefaultValue OBJECT-TYPE
SYNTAX INTEGER (0 .. 7)
ACCESS read-write
STATUS mandatory
DESCRIPTION "Default CoS value assigned to the ethernet
frames that don't have VLAN or Q-in-Q tag."
DEFVAL { 0 }
::= { hzIduQos 9 }
hzIduCutThroughProcessing OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Sets cut through processing on/off."
::= { hzIduQos 10 }
--
-- hzIduCosWfq
--
hzIduQosPolicy OBJECT-TYPE
SYNTAX INTEGER { strict-priority ( 1 ) , wfq ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Sets the Qos policy."
::= { hzIduQos 11 }
hzIduCosWfqWeight OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 32 ) )
ACCESS read-write
STATUS mandatory
DESCRIPTION "The weight assigned to each of the 4 cos queue. The wireless bandwidth is distributed amongst the
queues proportional to their weight.
The weights have values from 0-15, where 0 is the lowest weight and
15 is the highest weight.
Setting the Cos weight example: 1 2 3 4."
::= { hzIduQos 12 }
--
-- hzIduRapidLinkShutdown
--
hzIduRlsEnable OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "The Rapid Link Shutdown feature: enabled or disabled.
Changing this option requires a system reset."
DEFVAL { disabled }
::= { hzIduRapidLinkShutdown 1 }
hzIduRlsHardFaultMonitor OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Enable the rlsHardFaultMonitor for rapid detection of severely degrade link. When disabled
only the RLS Link Degrade Monitor is used."
DEFVAL { off }
::= { hzIduRapidLinkShutdown 2 }
hzIduRlsWirelessPortOption OBJECT-TYPE
SYNTAX INTEGER { anyport ( 1 ) , bothports ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "anyport - If the IDU is operating with two wireless ports and any one of the wireless ports goes down disables the ethernet port.
bothports - In the above condition, this feature disables the ehternet traffic through the faulty wireless link but continuously send
ethernet traffic through the other good wireless port. If the remaining wireless port also exceeds the error thereshold, ethernet port
will be disabled"
DEFVAL { off }
::= { hzIduRapidLinkShutdown 3 }
hzIduRlsAutomaticLinkReestablish OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "If this feature is enabled, the link will be automatically reestablished
If this feature is disabled, the user must explicitly use the manualReestablish object
to bring the link back up"
DEFVAL { disabled }
::= { hzIduRapidLinkShutdown 4 }
hzIduRlsManualLinkReestablish OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "This object is writeable ONLY if automaticLinkReestablish is set to disabled.
The user explicitly brings the link back up by setting this object to enabled.
The user explicitly brings the link down by setting this object to disabled.
to bring the link back up"
DEFVAL { disabled }
::= { hzIduRapidLinkShutdown 5 }
hzIduWriteRlsMonitorParametersToSystem OBJECT-TYPE
SYNTAX INTEGER { enabled ( 1 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "This writes RLS soft and hard fault monitor parameters to RAM
Reading this object returns '1'."
DEFVAL { 0 }
::= { hzIduRapidLinkShutdown 6 }
hzIduRlsDroppedFramesThresholdOverride OBJECT-TYPE
SYNTAX INTEGER { enabled ( 1 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "If the Ethernet is down due to Queue-Based Rls shutdown, this will bring the ethernet back and obey the queue settings.
Reading this object returns '1'."
DEFVAL { 0 }
::= { hzIduRapidLinkShutdown 7 }
hzIduRlsDroppedFramesThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduRlsDroppedFramesThresholdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table of RLS Queue Monitor Parameters"
::= { hzIduRapidLinkShutdown 8 }
hzIduRlsDroppedFramesThresholdEntry OBJECT-TYPE
SYNTAX HzIduRlsDroppedFramesThresholdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "RLS Queue Parameters "
INDEX { hzIduRlsDroppedFramesThresholdIndex }
::= { hzIduRlsDroppedFramesThresholdTable 1 }
HzIduRlsDroppedFramesThresholdEntry ::= SEQUENCE {
hzIduRlsDroppedFramesThresholdIndex INTEGER,
hzIduRlsAllowedDroppedFrameRateValue DisplayString,
hzIduRlsDroppedFrameMonitorPeriod INTEGER
}
hzIduRlsDroppedFramesThresholdIndex OBJECT-TYPE
SYNTAX INTEGER { queue-1 ( 1 ), queue-2 ( 2 ), queue-3 ( 3 ), queue-4 ( 4 )}
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each interface. "
::= { hzIduRlsDroppedFramesThresholdEntry 1 }
hzIduRlsAllowedDroppedFrameRateValue OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION "Maximum allowed ethernet frame drop rate. If the average drop rate exceeds this threshold in any of the 4 queues, the Ethernet port will be shut down.
This feture is availabe only with bothports option"
::= { hzIduRlsDroppedFramesThresholdEntry 2 }
hzIduRlsDroppedFrameMonitorPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "The monitoring period in seconds. "
::= { hzIduRlsDroppedFramesThresholdEntry 3 }
hzIduRlsSoftFaultMonitorTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduRlsSoftFaultMonitorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table of RLS Soft Fault Monitor Parameters"
::= { hzIduRapidLinkShutdown 9 }
hzIduRlsSoftFaultMonitorEntry OBJECT-TYPE
SYNTAX HzIduRlsSoftFaultMonitorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "RLS Parameters for Soft Fault Monitoring"
INDEX { hzIduRlsSoftFaultMonitorIndex }
::= { hzIduRlsSoftFaultMonitorTable 1 }
HzIduRlsSoftFaultMonitorEntry ::= SEQUENCE {
hzIduRlsSoftFaultMonitorIndex INTEGER,
hzIduRlsEstablishErredFrameThreshold INTEGER,
hzIduRlsShutdownErredFrameThreshold INTEGER,
hzIduRlsEstablishNumberOfSamples INTEGER,
hzIduRlsShutdownNumberOfSamples INTEGER,
hzIduRlsEstablishSamplePeriod INTEGER,
hzIduRlsShutdownSamplePeriod INTEGER,
hzIduRlsQuickShutdownSamplePeriod INTEGER
}
hzIduRlsSoftFaultMonitorIndex OBJECT-TYPE
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each interface. "
::= { hzIduRlsSoftFaultMonitorEntry 1 }
hzIduRlsEstablishErredFrameThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Maximum erred blocks, per sample, allowed for link establishment."
::= { hzIduRlsSoftFaultMonitorEntry 2 }
hzIduRlsShutdownErredFrameThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Minimum erred blocks, per sample, allowed before link shutdown."
::= { hzIduRlsSoftFaultMonitorEntry 3 }
hzIduRlsEstablishNumberOfSamples OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Minimum number of consecutive good samples required before link is established."
::= { hzIduRlsSoftFaultMonitorEntry 4 }
hzIduRlsShutdownNumberOfSamples OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Minimum number of consecutive erred samples before link is shutdown."
::= { hzIduRlsSoftFaultMonitorEntry 5 }
hzIduRlsEstablishSamplePeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Period of Time, in milliseconds, for monitoring Establish Erred Frame Threshold."
::= { hzIduRlsSoftFaultMonitorEntry 6 }
hzIduRlsShutdownSamplePeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Period of Time, in milliseconds, for monitoring Shutdown Erred Frame Threshold."
::= { hzIduRlsSoftFaultMonitorEntry 7 }
hzIduRlsQuickShutdownSamplePeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Minimum number of milliseconds required to classify samples as erred."
::= { hzIduRlsSoftFaultMonitorEntry 8 }
hzIduHardFaultMonitorTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduHardFaultMonitorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table of RLS Hard Fault Monitor Parameters"
::= { hzIduRapidLinkShutdown 10 }
hzIduHardFaultMonitorEntry OBJECT-TYPE
SYNTAX HzIduHardFaultMonitorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "RLS Parameters for Hard Fault Monitoring"
INDEX { hzIduHardFaultMonitorIndex }
::= { hzIduHardFaultMonitorTable 1 }
HzIduHardFaultMonitorEntry ::= SEQUENCE {
hzIduHardFaultMonitorIndex INTEGER,
hzIduRlsHardFaultSamplePeriod INTEGER,
hzIduRlsHardFaultThreshold INTEGER
}
hzIduHardFaultMonitorIndex OBJECT-TYPE
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each interface. "
::= { hzIduHardFaultMonitorEntry 1 }
hzIduRlsHardFaultSamplePeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "The period of time, in milliseconds, for which the
rlsFaultThreshold is applied."
::= { hzIduHardFaultMonitorEntry 2 }
hzIduRlsHardFaultThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "Acceptalbe errored block rate in percent"
::= { hzIduHardFaultMonitorEntry 3 }
hzIduRlsReceiveSignalLevelMonitorTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduRlsReceiveSignalLevelMonitorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table of RLS RSL Monitor Parameters"
::= { hzIduRapidLinkShutdown 11 }
hzIduRlsReceiveSignalLevelMonitorEntry OBJECT-TYPE
SYNTAX HzIduRlsReceiveSignalLevelMonitorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "RLS RSL Monitor Parameters"
INDEX { hzIduRlsReceiveSignalLevelMonitorIndex }
::= { hzIduRlsReceiveSignalLevelMonitorTable 1 }
HzIduRlsReceiveSignalLevelMonitorEntry ::= SEQUENCE {
hzIduRlsReceiveSignalLevelMonitorIndex INTEGER,
hzIduRlsMakeRslMonitorRslValue DisplayString,
hzIduRlsMakeRslMonitorPeriod INTEGER
}
hzIduRlsReceiveSignalLevelMonitorIndex OBJECT-TYPE
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each interface. "
::= { hzIduRlsReceiveSignalLevelMonitorEntry 1 }
hzIduRlsMakeRslMonitorRslValue OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 24 ) )
ACCESS read-write
STATUS mandatory
DESCRIPTION "The RSL threshold, in dBm. When Link is inactive and if RSL
is higher than this threshold for a desired
period, the link will become active."
::= { hzIduRlsReceiveSignalLevelMonitorEntry 2 }
hzIduRlsMakeRslMonitorPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION "The desired period, in seconds. When Link is inactive and if RSL
is higher than the desired threshold for this
period, the link will become active."
::= { hzIduRlsReceiveSignalLevelMonitorEntry 3 }
--
-- rlsStatus
--
hzIduRlsStatus OBJECT IDENTIFIER
::= { hzIduRapidLinkShutdown 12 }
hzIduRlsCurrentDroppedFramesTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduRlsCurrentDroppedFramesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table of RLS Currently Observed Queue Monitor Parameters"
::= { hzIduRlsStatus 1 }
hzIduRlsCurrentDroppedFramesEntry OBJECT-TYPE
SYNTAX HzIduRlsCurrentDroppedFramesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "RLS Currently Observed Queue Monitor Parameters"
INDEX { hzIduRlsCurrentDroppedFramesIndex }
::= { hzIduRlsCurrentDroppedFramesTable 1 }
HzIduRlsCurrentDroppedFramesEntry ::= SEQUENCE {
hzIduRlsCurrentDroppedFramesIndex INTEGER,
hzIduRlsCurrentDroppedFramesRateValue DisplayString,
hzIduRlsCurrentDroppedFrameMonitorPeriod INTEGER,
hzIduRlsCurrentQueueStatus DisplayString
}
hzIduRlsCurrentDroppedFramesIndex OBJECT-TYPE
SYNTAX INTEGER { queue-1 ( 1 ), queue-2 ( 2 ), queue-3 ( 3 ), queue-4 ( 4 )}
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each interface. "
::= { hzIduRlsCurrentDroppedFramesEntry 1 }
hzIduRlsCurrentDroppedFramesRateValue OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "RLS Current Ethernet Frame drop rate"
::= { hzIduRlsCurrentDroppedFramesEntry 2 }
hzIduRlsCurrentDroppedFrameMonitorPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Queue Monitoring time"
::= { hzIduRlsCurrentDroppedFramesEntry 3 }
hzIduRlsCurrentQueueStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Queue Status - OK: drop rate is within the threshold, Activated: Exceeded the drop threshold"
::= { hzIduRlsCurrentDroppedFramesEntry 4 }
hzIduRlsStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduRlsStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table of RLS Parameters and states"
::= { hzIduRlsStatus 2 }
hzIduRlsStatusEntry OBJECT-TYPE
SYNTAX HzIduRlsStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "RLS Parameters and states"
INDEX { hzIduRlsStatusIndex }
::= { hzIduRlsStatusTable 1 }
HzIduRlsStatusEntry ::= SEQUENCE {
hzIduRlsStatusIndex INTEGER,
hzIduRlsOption DisplayString,
hzIduRlsState DisplayString,
hzIduRlsMismatchState DisplayString,
hzIduDegradeMonitorState DisplayString,
hzIduHardFaultMonitorState DisplayString,
hzIduMakeRslThresholdState DisplayString,
hzIduPeerRlsState DisplayString,
hzIduRadioInterfaceState DisplayString,
hzIduNetworkInterfaceState DisplayString,
hzIduUserConfiguredEstablishFer DisplayString,
hzIduMinimumAchievableEstablishFer DisplayString,
hzIduUserConfiguredShutdownFer DisplayString,
hzIduMinimumAchievableShutdownFer DisplayString,
hzIduUserConfiguredEstablishMonitorTime INTEGER,
hzIduActualEstablishMonitorTime INTEGER,
hzIduUserConfiguredShutdownMonitorTime INTEGER,
hzIduActualShutdownMonitorTime INTEGER
}
hzIduRlsStatusIndex OBJECT-TYPE
SYNTAX INTEGER { wireless-port-1 ( 1 ), wireless-port-2 ( 2 ) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each interface. "
::= { hzIduRlsStatusEntry 1 }
hzIduRlsOption OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "RLS Option. On Basic: RLS enabled with base degrade monitoring;
On Advanced: RLS enabled with hard fault monitoring;
On Anyport: If any one of the wireless links exceeds the threshold Ehternet Port will be shut down
On Bothports: Both wireless links should exceed the threshold to bring the Ethernet Port down
Off: Entire RLS feature disabled."
::= { hzIduRlsStatusEntry 2 }
hzIduRlsState OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Rapid Link Shutdown State. If the state is activated, that means
The wireless link is down for Ethernet traffic; If the state is inactivated, that means that
wireless link is up for Ethernet traffic."
::= { hzIduRlsStatusEntry 3 }
hzIduRlsMismatchState OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "RLS Mismatch State. If the state is activated, that means RLS
configuration is mismatched with peer. If the state is OK,
that means RLS configuration is matched with peer."
::= { hzIduRlsStatusEntry 4 }
hzIduDegradeMonitorState OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Degrade Monitor State. If the state is activated, that means
the RLS Degrade Monitor is asserting the link down. If the
state is OK, that means the RLS Degrade Monitor is asserting
the link up."
::= { hzIduRlsStatusEntry 5 }
hzIduHardFaultMonitorState OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Hard Fault Monitor State. If the state is activated, that means
the Hard Fault Monitor is asserting the link down. If the state
is OK, that means the RLS Hard Fault Monitor is asserting the
link up."
::= { hzIduRlsStatusEntry 6 }
hzIduMakeRslThresholdState OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Make RSL Threshold State. If the state is not met, that means the
RLS signal level is below the threshold value. If the state is OK,
that means the RLS signal level is above the threshold value."
::= { hzIduRlsStatusEntry 7 }
hzIduPeerRlsState OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Peer RLS State. If the state is activated, that means the peer has
activated RLS. If the state is OK, that means the Peer hasn't
activated RLS."
::= { hzIduRlsStatusEntry 8 }
hzIduRadioInterfaceState OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Radio Interface State. If the state is down, that means The radio
interface is not operational(muted,disconnected, not configured).
If the state is up, that means the radio interface is operational."
::= { hzIduRlsStatusEntry 9 }
hzIduNetworkInterfaceState OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Network Interface State. If the state is down, that means the network
interface (Ethernet/PHY) is not operational(disconnected, not
configured). If the state is up, that means the network interface
(Ethernet/PHY) is operational."
::= { hzIduRlsStatusEntry 10 }
hzIduUserConfiguredEstablishFer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "User Configured Establish Frame Error Ratio required for the
link to be restored to service, set by the user. An example
value being '1.0E-7'."
::= { hzIduRlsStatusEntry 11 }
hzIduMinimumAchievableEstablishFer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Minimum achievable Frame Error Ratio required for the link to be
restored to service. An example value being '1.0E-7'."
::= { hzIduRlsStatusEntry 12 }
hzIduUserConfiguredShutdownFer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "User Configured Shutdown Frame Error Ratio required for the
link to remain in-service, set by the user. An example value
being '1.0E-7'."
::= { hzIduRlsStatusEntry 13 }
hzIduMinimumAchievableShutdownFer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Minimum achievable Frame Error Ratio required for the link to
remain in-service. An example value being '1.0E-7'."
::= { hzIduRlsStatusEntry 14 }
hzIduUserConfiguredEstablishMonitorTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "User Configured Establish Monitor Time, in milliseconds, for
which the 'User Configured Establish FER' must be achieved
to bring link into service, set by user"
::= { hzIduRlsStatusEntry 15 }
hzIduActualEstablishMonitorTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Actual Establish Monitor Time, in milliseconds, for which the
'User Configured Establish FER' must be achieved to bring
link into service, it's a multiple of the establish sample
period required to observe the FER"
::= { hzIduRlsStatusEntry 16 }
hzIduUserConfiguredShutdownMonitorTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "User Configured Shutdown Monitor Time, in milliseconds, for which
the 'User Configured Shutdown FER' must be met for the link to
remain in-service, set by user."
::= { hzIduRlsStatusEntry 17 }
hzIduActualShutdownMonitorTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Actual Shutdown Monitor Time, in milliseconds, for which the 'User
Configured Shutdown FER' must be met for the link to remain
in-service, it's a multiple of the shutdown sample period required
to observe the FER"
::= { hzIduRlsStatusEntry 18 }
--
-- hzIduSntp
--
hzIduSntpEnable OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Indicates whether SNTP feature is enabled."
DEFVAL { enabled }
::= { hzIduSntp 1 }
hzIduSntpOffset OBJECT-TYPE
-- This value is shown in 10ths of hours
SYNTAX INTEGER ( -140 .. 140 )
ACCESS read-write
STATUS mandatory
DESCRIPTION "System time offset from GMT in tenths of hours. For example, an offset of 10 indicates 10 tenths, or 1 hour. An offset of 5 indicates half an hour."
DEFVAL { -40 }
::= { hzIduSntp 2 }
hzIduSntpServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduSntpServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Table containing sntp server entries"
::= { hzIduSntp 3 }
hzIduSntpServerEntry OBJECT-TYPE
SYNTAX HzIduSntpServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Contains the sntp server information"
INDEX { hzIduSntpServerIndex }
::= { hzIduSntpServerTable 1 }
HzIduSntpServerEntry ::= SEQUENCE {
hzIduSntpServerIndex INTEGER,
hzIduSntpServerIpAddress IpAddress,
hzIduSntpServerStatus INTEGER,
hzIduSntpServerStratum INTEGER
}
hzIduSntpServerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each server."
::= { hzIduSntpServerEntry 1 }
hzIduSntpServerIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION "The IP address of the server."
::= { hzIduSntpServerEntry 2 }
hzIduSntpServerStatus OBJECT-TYPE
SYNTAX INTEGER { good (1) , failed (2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION "The status of the sntp server."
::= { hzIduSntpServerEntry 3 }
hzIduSntpServerStratum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Specifies the stratum of a server, 0 for failed server"
::= { hzIduSntpServerEntry 4 }
--
-- hzIduLogs
--
hzIduEventLogEnable OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Indicates whether event log is enabled."
DEFVAL { enabled }
::= { hzIduLogs 1 }
hzIduPerfmLogEnable OBJECT-TYPE
SYNTAX INTEGER { disabled ( 1 ) , enabled ( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION "Indicates whether performance log is enabled."
DEFVAL { enabled }
::= { hzIduLogs 2 }
hzIduPerfmLogInterval OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 10 ) )
ACCESS read-write
STATUS mandatory
DESCRIPTION "Performance statistics are logged periodically by this interval. The interval can be up to 24:00:00 (24 hours) and as short as 00:00:15 (15 seconds)."
::= { hzIduLogs 3 }
--
-- hzIduRadius
--
hzIduRadiusSuperUserAuthentication OBJECT-TYPE
SYNTAX INTEGER { off ( 1 ) , on( 2 ) }
ACCESS read-write
STATUS mandatory
DESCRIPTION " The set strict mode on or off"
DEFVAL { off }
::= { hzIduRadius 1 }
hzIduRadiusServerTimeOut OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION " Timeout period for authentication requests"
DEFVAL { 0 }
::= { hzIduRadius 2 }
hzIduRadiusServerDeadTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION " Time to declare an unresponsive server 'dead'"
DEFVAL { 0 }
::= { hzIduRadius 3 }
hzIduRadiusServerReTransmit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of retransmits to an unresponsive server"
::= { hzIduRadius 4 }
hzIduRadiusServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF HzIduRadiusServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Table containing radius server entries"
::= { hzIduRadius 5 }
hzIduRadiusServerEntry OBJECT-TYPE
SYNTAX HzIduRadiusServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Contains the sntp server information"
INDEX { hzIduRadiusServerIndex }
::= { hzIduRadiusServerTable 1 }
HzIduRadiusServerEntry ::= SEQUENCE {
hzIduRadiusServerIndex INTEGER,
hzIduRadiusCfgdHostIpAddress IpAddress,
hzIduRadiusActiveHostIpAddress IpAddress
}
hzIduRadiusServerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each server."
::= { hzIduRadiusServerEntry 1 }
hzIduRadiusCfgdHostIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION "The IP address of the configured radius server."
::= { hzIduRadiusServerEntry 2 }
hzIduRadiusActiveHostIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION "The IP address of the active radius server."
::= { hzIduRadiusServerEntry 3 }
--
-- TRAP DEFINITIONS
--
coldStart TRAP-TYPE
ENTERPRISE snmp
DESCRIPTION
"A coldStart trap signifies that the sending protocol entity is reinitializing itself such that the agent's configuration or the protocol entity implementation may be altered."
::= 0
-- for generic traps real trap value of linkDown is 2.
linkDown TRAP-TYPE
ENTERPRISE snmp
VARIABLES {ifIndex}
DESCRIPTION
"A linkDown trap signifies that the sending protocol entity recognizes a failure in one of the communication links represented in the agent's configuration."
::= 1
-- for generic traps real trap value of linkup is 3.
linkUp TRAP-TYPE
ENTERPRISE snmp
VARIABLES {ifIndex}
DESCRIPTION
"A linkUp trap signifies that the sending protocol entity recognizes that one of the communication links represented in the agent's configuration has come up."
::= 2
hzIduExplicitAuthenticationFailureV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "Authentication of the peer horizon node has failed. The severity is critical, the probable cause is an incorrect authentication configuration on horizon faulty cable between the modem and radio, and recommended course of action is to check both ends of the link."
::= 3
hzIduExplicitAuthenticationFailureClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "The condition has cleared. The peer node is now authenticated."
::= 4
hzIduAamConfigMisMatchV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "Adaptive modulation configuration mismatch"
::= 5
hzIduAamConfigMisMatchClearV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "Adaptive modulation configuration mismatch cleared"
::= 6
hzIduAamActiveV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "Adaptive modulation on and system running on lowest modulation"
::= 7
hzIduAamActiveClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "Adaptive modulation on system running on higher modulation"
::= 8
hzIduAtpcConfigMismatchV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "ATPC is set to on at near end however in the far end it is set to off."
::= 9
hzIduAtpcConfigMismatchClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "ATPC configuration mismatch is cleared"
::= 10
hzIduSntpServersUnreachableV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "Can't reach any of the sntp servers"
::= 11
hzIduSntpServersUnreachableClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "At least one of SNTP servers is reachable"
::= 12
hzIduFrequencyFileInvalidV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "When the executing frequency file is invalid,
this trap is generated."
::= 13
hzIduEnetPort1DroppedFramesThresholdExceededV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "The ethernet dropped frames threshold has been detected above its threshold value."
::= 14
hzIduEnetPort1DroppedFramesThresholdExceededClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "The condition has cleared.The ethernet dropped frames threshold is now below its threshold value."
::= 15
hzIduEnetPort1BwUtilizationThresholdExceededV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "The ethernet bandwidth threshold has been detected above its threshold value."
::= 16
hzIduEnetPort1BwUtilizationThresholdExceededClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "The condition has cleared. The ethernet bandwidth threshold is now below its threshold value."
::= 17
hzIduEnetPort1RlsMismatchV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "RLS mismatch"
::= 18
hzIduEnetPort1RlsMismatchClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "RLS mismatch cleared"
::= 19
hzIduRlsQueueBasedShutdownActivatedv1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "RLS Queue-Based shutdown is activated"
::= 20
hzIduRlsQueueBasedShutdownActivatedClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "RLS Queue-Based shutdown is not activated"
::= 21
hzIduModemRxLossOfSignalLockV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduModemAlarmsIndex}
DESCRIPTION "Loss of signal lock from the demodulator. The severity is critical, the probable cause is lost synchronization with the far end, and recommended course of action is to check the operational state of both ends of the link."
::= 22
hzIduModemRxLossOfSignalLockClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduModemAlarmsIndex}
DESCRIPTION "The condition has cleared. The demodulator is synchronized."
::= 23
hzIduModemTxLossOfSyncV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduModemAlarmsIndex}
DESCRIPTION "Loss of sync bytes at the input of the modulator. The severity is critical, the probable cause is physical
interference in the air link, and recommended course of action is to check the line of site between the horizon nodes."
::= 24
hzIduModemTxLossOfSyncClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduModemAlarmsIndex}
DESCRIPTION "Tx Loss of sync bytes cleared."
::= 25
hzIduModemSnrBelowThresholdV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduModemAlarmsIndex}
DESCRIPTION "The demodulator SNR performance worse than programmed levels. The severity is major, the probable cause
is physical interference in the air link path or misalignment of the radios or severe weather conditions, and recommended course
of action is to check the line of site between the horizon nodes."
::= 26
hzIduModemSnrBelowThresholdClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduModemAlarmsIndex}
DESCRIPTION "SNR performance back to normal."
::= 27
hzIduModemEqualizerStressExceedThresholdV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduModemAlarmsIndex}
DESCRIPTION "Equalizer Stress measured within the demodulator exceeds the threshold value."
::= 28
hzIduModemEqualizerStressExceedThresholdClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduModemAlarmsIndex}
DESCRIPTION "Equalizer Stress measured within the demodulator is within the threshold value."
::= 29
hzIduEnetPort1ChannelizedRslBelowThresholdV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "The RSL has been detected below its minimum threshold."
::= 30
hzIduEnetPort1ChannelizedRslBelowThresholdClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "The condition has cleared. RSL is now above its minimum threshold."
::= 31
hzIduModemHardwareFaultV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduModemAlarmsIndex}
DESCRIPTION "Power supply circuitry failed. Should be sent for diagnosis."
::= 32
hzIduModemHardwareFaultClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduModemAlarmsIndex}
DESCRIPTION "Power supply circuitry is in good condition."
::= 33
hzIduModemProgrammingErrorV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduModemAlarmsIndex}
DESCRIPTION "Encountered problem while programming modem."
::= 34
hzIduModemProgrammingErrorClearedrV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduModemAlarmsIndex}
DESCRIPTION "Problem encountered while programming modem is gone."
::= 35
hzIduTtySessionCommencedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES { hzIduTtySessionUserName,
hzIduTtySessionUserConnectionType }
DESCRIPTION "A person has successfully gained access to the ascii management port (telnet, local management port, or HTTP). The username is included in the Trap."
::= 36
hzIduTtySessionTerminatedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES { hzIduTtySessionUserName,
hzIduTtySessionUserConnectionType }
DESCRIPTION "A person has logged out of an ascii management port (telnet, local management port, or HTTP). The username is included in the Trap."
::= 37
hzIduAtpcTxAtMaxPwrV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "ATPC auto-disabled (transmitting at coordinated power)."
::= 38
hzIduAtpcTxAtMaxPwrClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "ATPC has been disabled."
::= 39
-- Radio Traps 50+ restored for IDU --
hzIduRadioPLDROLostLockV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "The PLDRO/LO has lost lock on the radio. The severity is critical, the probable cause a faulty radio unit within AirPair, and recommended course of action is to replace the radio unit"
::= 40
hzIduRadioPLDROLostLockClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "The radio PLDRO/LO lost lock condition has cleared."
::= 41
hzIduRadioLostCommunicationV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "RS232 communication lost between IDU and the radio. The severity is critical, the probable cause is a faulty cable between the modem and radio, and recommended course of action is to check the connection."
::= 42
hzIduRadioLostCommunicationClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "RS232 communication has been re-establisted between IDU and the radio."
::= 43
hzIduRadioMismatchV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "The radio connected to the IDU modem does not match the frequency programmed into the modem unit. The severity is major, the probable cause is an incorrectly programmed modem or an incorrect radio type connected to the modem, and recommended course of action is to check the modem frequency settings and radio hardware version number or serial number."
::= 44
hzIduRadioMismatchClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "The condition has cleared. The radio matches the programmed parameters in the modem."
::= 45
hzIduRadioPowerAmpV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "The power amplifier on the radio is not operating within normal operating specifications. The severity is critical, the probable cause a faulty radio unit, and recommended course of action is to replace the radio unit."
::= 46
hzIduRadioPowerAmpClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "The power amplifier on the radio is now operating within normal specifications"
::= 47
hzIduRadioExcessiveTxCableLossV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "The radio cannot compensate for the calculated amount of Tx Cable Loss."
::= 48
hzIduRadioExcessiveTxCableLossClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "Excessive Tx Cable Loss cleared."
::= 49
hzIduHiPowerRadioDrainM1V1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "This applies to High Power Radios only. Indicates Power Amp Alarm (M1)."
::= 50
hzIduHiPowerRadioDrainM1ClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "This applies to High Power Radios only. Indicates Power Amp Alarm (M1) cleared."
::= 51
hzIduHiPowerRadioDrainM2V1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "This applies to High Power Radios only. Indicates Power Amp Alarm (M2)."
::= 52
hzIduHiPowerRadioDrainM2ClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "This applies to High Power Radios only. Indicates Power Amp Alarm (M2) cleared."
::= 53
hzIduHiPowerRadioTxDetectorV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "This applies to High Power Radios only. Indicates minimum power threshold has not been surpassed."
::= 54
hzIduHiPowerRadioTxDetectorClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "This applies to High Power Radios only. Indicates minimum power threshold alarm has cleared."
::= 55
hzIduSecondaryRadioIsActiveV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "Radio redundancy on, secondary radio is active."
::= 56
hzIduSecondaryRadioIsActiveClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "Radio redundancy, secondary radio is no longer active."
::= 57
hzIduRedundancySerialNumberMisMatchV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "The radio serial number programmed in flash and radio do not match."
::= 58
hzIduRedundancySerialNumberMisMatchClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "The radio serial number mismatch has cleared."
::= 59
hzIduRadioFirmwareMismatchV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "The radio connected to the IDU modem does not match the radio band or frequency bank specified by the user. As a result, the system
will not work."
::= 60
hzIduRadioFirmwareMismatchClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "Radio Firmnware mismatch cleared."
::= 61
hzIduSecondaryRadioNotdetectedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "Secondary radio not detected."
::= 62
hzIduSecondaryRadioNotdetectedClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "secondary Radio not detected alarm cleared."
::= 63
hzIduPrimaryRadioNotdetectedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "Primary Radio not detected."
::= 64
hzIduPrimaryRadioNotdetectedClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "Primary Radio not detected alarm cleared."
::= 65
hzIduFaultyPrimaryRadioV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "Faulty Primary Radio."
::= 66
hzIduFaultyPrimaryRadioClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "Faulty Primary Radio alarm cleared."
::= 67
hzIduRadioExcessiveTxCableLossChangeV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "Radio - Excessive Tx cable loss change detected."
::= 68
hzIduRadioExcessiveTxCableLossChangeClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "Radio - Excessive Tx cable loss change cleared."
::= 69
hzIduExcessiveRxCableLossV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "Radio - Excessive receive cable loss detected."
::= 70
hzIduExcessiveRxCableLossClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduRadioAlarmsIndex}
DESCRIPTION "Radio - Excessive receive cable loss cleared."
::= 71
hzIduRedundancyPrimaryPortNotSetV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "Redundancy: Primary Port not set."
::= 72
hzIduRedundancyPrimaryPortNotSetClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "Redundancy: Primary Port not set - cleared."
::= 73
hzIduRedundancySecondaryPortIsActiveV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "Redundancy: Secondary Port is Active."
::= 74
hzIduRedundancySecondaryPortIsActiveClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "Redundancy: Secondary Port is no longer Active"
::= 75
hzIduRedundancyPrimaryPortFaultyV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "Redundancy: Primary Port is Faulty."
::= 76
hzIduRedundancyPrimaryPortFaultyClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "Redundancy: Primary Port is no longer Faulty."
::= 77
hzIduRedundancySecondaryPortFaultyV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "Redundancy: Secondary Port is Faulty."
::= 78
hzIduRedundancySecondaryPortFaultyClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "Redundancy: secondary Port is no longer Faulty."
::= 79
hzIduFan1FailedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "Fan 1 has failed"
::= 80
hzIduFan1FailureClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "The Fan 1 Failure has Cleared"
::= 81
hzIduFan2FailedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "Fan 2 has failed"
::= 82
hzIduFan2FailureClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "The Fan 2 Failure has Cleared"
::= 83
hzIduFan3FailedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "Fan 3 has failed"
::= 84
hzIduFan3FailureClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "The Fan 3 Failure has Cleared"
::= 85
hzIduFan4FailedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "Fan 4 has failed"
::= 86
hzIduFan4FailureClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
DESCRIPTION "The Fan 4 Failure has Cleared"
::= 87
hzIduRlsShutdownActivatedv1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduModemAlarmsIndex}
DESCRIPTION "RLS shutdown is activated"
::= 88
hzIduRlsShutdownActivatedClearedV1Trap TRAP-TYPE
ENTERPRISE hzIduTrapConfig
VARIABLES {hzIduModemAlarmsIndex}
DESCRIPTION "RLS shutdown is not activated"
::= 89
END