477 lines
		
	
	
		
			16 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			477 lines
		
	
	
		
			16 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
-- *****************************************************************
 | 
						|
-- Juniper Enterprise Specific MIB: JUNIPER-POWER-MANAGEMENT
 | 
						|
--
 | 
						|
-- Copyright (c) 2009-2010, Juniper Networks, Inc.
 | 
						|
-- All rights reserved.
 | 
						|
--
 | 
						|
-- The contents of this document are subject to change without notice.
 | 
						|
-- *****************************************************************
 | 
						|
 | 
						|
JUNIPER-POWER-SUPPLY-UNIT-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
IMPORTS
 | 
						|
        MODULE-IDENTITY, OBJECT-TYPE
 | 
						|
                FROM SNMPv2-SMI
 | 
						|
        TEXTUAL-CONVENTION, DisplayString, TruthValue
 | 
						|
                FROM SNMPv2-TC
 | 
						|
        jnxContentsContainerIndex, jnxContentsL1Index,
 | 
						|
        jnxContentsL2Index, jnxContentsL3Index
 | 
						|
                FROM JUNIPER-MIB
 | 
						|
        jnxPsuMIBRoot
 | 
						|
                FROM JUNIPER-SMI;
 | 
						|
 | 
						|
jnxPsuMIB MODULE-IDENTITY
 | 
						|
    LAST-UPDATED "201010270000Z" -- Oct 27 00:00:00 2010 UTC
 | 
						|
    ORGANIZATION "Juniper Networks, Inc."
 | 
						|
    CONTACT-INFO
 | 
						|
        "Juniper Technical Assistance Center
 | 
						|
         Juniper Networks, Inc.
 | 
						|
         1133 Innovation Way
 | 
						|
         Sunnyvale, CA 94089
 | 
						|
         E-mail: support@juniper.net"
 | 
						|
 | 
						|
    DESCRIPTION
 | 
						|
            "The Juniper Supply Unit MIB definitions for enabling
 | 
						|
             power monitoring and management of a juniper device."
 | 
						|
 | 
						|
    -- revision history
 | 
						|
    REVISION  "201001270000Z" -- January 27 00:00:00 2010 UTC
 | 
						|
    DESCRIPTION
 | 
						|
            "Initial revision."
 | 
						|
    REVISION  "201005130000Z" -- May 13 00:00:00 2010 UTC
 | 
						|
    DESCRIPTION
 | 
						|
            "Added new OIDs for power budget statistics which gives details of
 | 
						|
            Power reserved for Chassis and the Total power allocated to Chassis
 | 
						|
            including for each FPC. 
 | 
						|
            Added new Table jnxPsuFpcPowerTable which gives the Priority
 | 
						|
            assigned and Power allocated to each FPC."
 | 
						|
    REVISION  "201010270000Z" -- Oct 27 00:00:00 2010 UTC
 | 
						|
    DESCRIPTION
 | 
						|
            "Added new OIDs for power budget statistics which gives details of
 | 
						|
            Power reserved for System dynamically."
 | 
						|
 | 
						|
    ::= { jnxPsuMIBRoot 1 }
 | 
						|
 | 
						|
jnxPsuNotifications     OBJECT IDENTIFIER ::= { jnxPsuMIB 1 }
 | 
						|
jnxPsuObjects           OBJECT IDENTIFIER ::= { jnxPsuMIB 2 }
 | 
						|
 | 
						|
--**********************************************************************
 | 
						|
-- PSU Scalar Objects 
 | 
						|
--**********************************************************************
 | 
						|
 | 
						|
jnxPsuScalars           OBJECT IDENTIFIER ::= { jnxPsuObjects 1 }
 | 
						|
 | 
						|
jnxPsuAvailableDeviceCount OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION
 | 
						|
        "Gives the number of PSU units available online in the System."
 | 
						|
    ::= { jnxPsuScalars 1 }
 | 
						|
 | 
						|
jnxPsuAvailableAveragePowerSupply OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION
 | 
						|
        "Gives the total average power that the System can supply from the
 | 
						|
        available online units in Watts."
 | 
						|
    ::= { jnxPsuScalars 2 }
 | 
						|
 | 
						|
jnxPsuAvailableMaxPowerSupply OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION
 | 
						|
        "Gives the total maximum power that the System can supply from the 
 | 
						|
        available online units in Watts."
 | 
						|
    ::= { jnxPsuScalars 3 }
 | 
						|
 | 
						|
jnxPsuRedundancy  OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER {
 | 
						|
                  nPlusNRedundancy(1),
 | 
						|
                  nPlusOneRedundancy(2),
 | 
						|
                  none(3)
 | 
						|
    }
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION
 | 
						|
        "PSU power redundancy configuration."
 | 
						|
    ::= { jnxPsuScalars 4 }
 | 
						|
 | 
						|
jnxPsuChassisPowerReserved OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION
 | 
						|
        "Power reserved for Chassis in Watts."
 | 
						|
    ::= { jnxPsuScalars 5 }
 | 
						|
 | 
						|
jnxPsuChassisPowerAllocated OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION
 | 
						|
        "Total power allocated for chassis and all the FPCs in Watts."
 | 
						|
    ::= { jnxPsuScalars 6 }
 | 
						|
 | 
						|
jnxPsuRedundantPowerAvailable OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION
 | 
						|
        "Power(in Watts) that is still available for allocation
 | 
						|
        even while supporting redundancy with the present usage."
 | 
						|
    ::= { jnxPsuScalars 7 }
 | 
						|
 | 
						|
jnxPsuTotalPowerAvailable OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION
 | 
						|
        "Power(in Watts) which could be made available for further
 | 
						|
        allocation without supporting any redundancy with the present usage."
 | 
						|
::= { jnxPsuScalars 8 }
 | 
						|
 | 
						|
jnxPsuChassisPowerConsumed OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION
 | 
						|
        "Total power consumed by the entire system rounded to the nearest integer.
 | 
						|
         This is calculated using the PowerFactor, Current and Voltage values 
 | 
						|
         of each PSU that is online and connected to the System."
 | 
						|
    ::= { jnxPsuScalars 9 }
 | 
						|
 | 
						|
jnxPsuTemperatureInflow OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION
 | 
						|
        "Average inflow temperature calculated from all 
 | 
						|
        the available input sensors on the master RE."
 | 
						|
 | 
						|
    ::= { jnxPsuScalars 10 }
 | 
						|
 | 
						|
jnxPsuTemperatureOutflow OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION
 | 
						|
        "Average outflow temperature calculated from all 
 | 
						|
        the available output sensors on the master RE."
 | 
						|
    ::= { jnxPsuScalars 11 }
 | 
						|
 | 
						|
jnxPsuTemperatureInflowSamples OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION
 | 
						|
        "The number of samples being taken while calculating
 | 
						|
        jnxPsuTemperatureInflow."
 | 
						|
 | 
						|
    ::= { jnxPsuScalars 12 }
 | 
						|
 | 
						|
jnxPsuTemperatureOutflowSamples OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION
 | 
						|
        "The number of samples being taken while calculating
 | 
						|
        jnxPsuTemperatureOutflow."
 | 
						|
 | 
						|
    ::= { jnxPsuScalars 13 }
 | 
						|
 | 
						|
--**********************************************************************
 | 
						|
-- Device POWER
 | 
						|
--**********************************************************************
 | 
						|
 | 
						|
jnxPsuTable  OBJECT-TYPE
 | 
						|
    SYNTAX        SEQUENCE OF JnxPsuEntry 
 | 
						|
    MAX-ACCESS    not-accessible
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "A list of power entries for each PSU component."
 | 
						|
    ::= { jnxPsuObjects 2 }
 | 
						|
 | 
						|
jnxPsuEntry    OBJECT-TYPE
 | 
						|
    SYNTAX        JnxPsuEntry
 | 
						|
    MAX-ACCESS    not-accessible
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "Defines an entry in jnxPsuTable. "
 | 
						|
    INDEX         { jnxContentsContainerIndex,
 | 
						|
                    jnxContentsL1Index,
 | 
						|
                    jnxContentsL2Index,
 | 
						|
                    jnxContentsL3Index }
 | 
						|
 | 
						|
    ::= { jnxPsuTable 1 }
 | 
						|
 | 
						|
JnxPsuEntry ::= 
 | 
						|
    SEQUENCE { 
 | 
						|
        jnxPsuAvgPower    INTEGER,
 | 
						|
        jnxPsuMaxPower    INTEGER,
 | 
						|
        jnxPsuMode        INTEGER,
 | 
						|
        jnxPsuOutletCount INTEGER
 | 
						|
    }
 | 
						|
 | 
						|
jnxPsuAvgPower   	OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "Buffer that contains the average power used, in Watts 
 | 
						|
                  for each component."
 | 
						|
    ::= { jnxPsuEntry 1 }
 | 
						|
                 
 | 
						|
jnxPsuMaxPower   	OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "Buffer that contains the max power available, in Watts 
 | 
						|
                  for each component."
 | 
						|
    ::= { jnxPsuEntry 2 }
 | 
						|
 | 
						|
jnxPsuMode   OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER {
 | 
						|
                      single(1),
 | 
						|
                      three(3)
 | 
						|
                  }
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "Mode for each PSU component."
 | 
						|
    ::= { jnxPsuEntry 3 }
 | 
						|
 | 
						|
jnxPsuOutletCount OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "The number of outlets (regardless of their current state)
 | 
						|
                  present on this psu component, default is 0."
 | 
						|
    DEFVAL        { 0 }
 | 
						|
    ::= { jnxPsuEntry 4 }
 | 
						|
 | 
						|
--**********************************************************************
 | 
						|
-- Environment
 | 
						|
--**********************************************************************
 | 
						|
 | 
						|
jnxPsuEnvironmentTable OBJECT-TYPE
 | 
						|
    SYNTAX        SEQUENCE OF JnxPsuEnvironmentEntry
 | 
						|
    MAX-ACCESS    not-accessible
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "A list of PSU Environment entries."
 | 
						|
    ::= { jnxPsuObjects 3 }
 | 
						|
 | 
						|
jnxPsuEnvironmentEntry OBJECT-TYPE
 | 
						|
    SYNTAX       JnxPsuEnvironmentEntry
 | 
						|
    MAX-ACCESS   not-accessible
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION  "Defines an entry in jnxPsuEnvironmentTable."
 | 
						|
    INDEX        { jnxContentsContainerIndex,
 | 
						|
                   jnxContentsL1Index,
 | 
						|
                   jnxContentsL2Index,
 | 
						|
                   jnxContentsL3Index }
 | 
						|
    ::= { jnxPsuEnvironmentTable 1 }
 | 
						|
 | 
						|
JnxPsuEnvironmentEntry ::=
 | 
						|
    SEQUENCE {
 | 
						|
        jnxPsuThermalValue    INTEGER,
 | 
						|
        jnxPsuHumidityValue   INTEGER
 | 
						|
    }
 | 
						|
 | 
						|
jnxPsuThermalValue  OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "Temparature at each component in degrees Celsius rounded to
 | 
						|
                  the nearest integer."
 | 
						|
    ::= { jnxPsuEnvironmentEntry 1 }
 | 
						|
 | 
						|
jnxPsuHumidityValue  OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "Humidity at each component in percentage."
 | 
						|
    ::= { jnxPsuEnvironmentEntry 2 }
 | 
						|
 | 
						|
--**********************************************************************
 | 
						|
-- OUTLETS
 | 
						|
--**********************************************************************
 | 
						|
 | 
						|
jnxPsuOutletTable OBJECT-TYPE
 | 
						|
    SYNTAX        SEQUENCE OF JnxPsuOutletEntry
 | 
						|
    MAX-ACCESS    not-accessible
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "Gives details of each Power outlet`s state,
 | 
						|
                   capacity to supply power, and other details."
 | 
						|
    ::= { jnxPsuObjects 4 }
 | 
						|
 | 
						|
jnxPsuOutletEntry OBJECT-TYPE
 | 
						|
    SYNTAX       JnxPsuOutletEntry
 | 
						|
    MAX-ACCESS   not-accessible
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION  "A value contained within the OutletEntry"
 | 
						|
    INDEX        { jnxContentsContainerIndex,
 | 
						|
                   jnxContentsL1Index,
 | 
						|
                   jnxContentsL2Index,
 | 
						|
                   jnxContentsL3Index }
 | 
						|
     ::= { jnxPsuOutletTable 1 }
 | 
						|
 | 
						|
JnxPsuOutletEntry ::= 
 | 
						|
    SEQUENCE {
 | 
						|
	jnxPsuOutletName                     DisplayString,
 | 
						|
	jnxPsuOutletDescription              DisplayString,
 | 
						|
	jnxPsuOutletAvgPower                 INTEGER,
 | 
						|
	jnxPsuOutletMaxPower                 INTEGER,
 | 
						|
	jnxPsuOutletCurrent                  INTEGER,
 | 
						|
	jnxPsuOutletStatus                   INTEGER,
 | 
						|
	jnxPsuOutletVoltage                  INTEGER,
 | 
						|
	jnxPsuOutletPowerFactorValue         INTEGER,
 | 
						|
	jnxPsuOutletPowerConsumed            INTEGER
 | 
						|
    }
 | 
						|
 | 
						|
jnxPsuOutletName  OBJECT-TYPE
 | 
						|
    SYNTAX        DisplayString(SIZE (0..15))
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "Outlet name associated to the power supply unit for 
 | 
						|
                   each PSU Component."
 | 
						|
    ::= { jnxPsuOutletEntry 1 }
 | 
						|
 | 
						|
jnxPsuOutletDescription	OBJECT-TYPE
 | 
						|
    SYNTAX        DisplayString(SIZE (0..63))
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "Outlet description associated to the power supply unit for 
 | 
						|
                   each PSU Component."
 | 
						|
    ::= { jnxPsuOutletEntry 2 }
 | 
						|
 | 
						|
jnxPsuOutletAvgPower OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "Buffer that contains the average power used, in Watts for each component."
 | 
						|
    ::= { jnxPsuOutletEntry 3 }
 | 
						|
		 
 | 
						|
jnxPsuOutletMaxPower OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "Buffer that contains the maximum power available, in Watts for each component."
 | 
						|
    ::= { jnxPsuOutletEntry 4 }
 | 
						|
		 
 | 
						|
jnxPsuOutletCurrent OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "PSU output current in milliamps rounded to the nearest
 | 
						|
                  integer."
 | 
						|
    ::= { jnxPsuOutletEntry 5 }
 | 
						|
                  
 | 
						|
jnxPsuOutletStatus  OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER {
 | 
						|
                      off(0),
 | 
						|
                      on(1)
 | 
						|
                  }
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "The value of the operational status for the given outlet.
 | 
						|
                   This can also be used to set the outlet state"
 | 
						|
    ::= { jnxPsuOutletEntry 8 }
 | 
						|
 | 
						|
jnxPsuOutletVoltage OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "Output voltage in Volts rounded to the nearest integer."
 | 
						|
    ::= { jnxPsuOutletEntry 9 }
 | 
						|
 | 
						|
--
 | 
						|
-- NOTE: jnxPsuOutletPowerFactorValue does NOT return the traditional
 | 
						|
-- "power factor", defined as real power in watts divided by apparent 
 | 
						|
-- power in volt-amperes.  Instead it returns "efficiency" which is  
 | 
						|
-- defined as power output divided by power input.
 | 
						|
--
 | 
						|
jnxPsuOutletPowerFactorValue OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "Power factor percentage of each PSU (2k/3k).
 | 
						|
 | 
						|
                  Algorithm for calculation of Power Factor is below.
 | 
						|
                  For PowerOut values that fall in between 618.93W and 915.24W,
 | 
						|
                  say 700W, the appropriate PF ranges from 0.910191 & 
 | 
						|
                  0.917994. Following linear equation could help deduce a
 | 
						|
                  fairly accurate input power value.
 | 
						|
 
 | 
						|
                  Linear equation y = mx + b (where m is the slope and b is 
 | 
						|
                  the Y intercept)
 | 
						|
 | 
						|
                  Slope m = (y2 - y1) / (x2 - x1)
 | 
						|
                  Y intercept  b = y - mx
 | 
						|
 
 | 
						|
                  Plugging it all together for our example:
 | 
						|
 
 | 
						|
                  m = (915.24 - 618.93) / (0.917994 - 0.910191) = 37973.86
 | 
						|
                  b = 915.24 - (37973.86 * 0.917994) = -33944.5
 | 
						|
 
 | 
						|
                  for 700W (y), our efficiency (x) would then be:
 | 
						|
 
 | 
						|
                  x = (700 - (-33944.5)) / 37973.86 = 0.912326 = 91%
 | 
						|
 | 
						|
                  PowerIn = 700W /0.912326 = 767.26W "
 | 
						|
 | 
						|
    ::= { jnxPsuOutletEntry 10 }
 | 
						|
 | 
						|
jnxPsuOutletPowerConsumed OBJECT-TYPE
 | 
						|
    SYNTAX        INTEGER
 | 
						|
    MAX-ACCESS    read-only
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "Power Consumed by each outlet units in Watts."
 | 
						|
    ::= { jnxPsuOutletEntry 11 }
 | 
						|
 | 
						|
                  
 | 
						|
--**********************************************************************
 | 
						|
-- FPC Power allocated information 
 | 
						|
--**********************************************************************
 | 
						|
 | 
						|
jnxPsuFpcPowerTable OBJECT-TYPE
 | 
						|
    SYNTAX        SEQUENCE OF JnxPsuFpcPowerEntry
 | 
						|
    MAX-ACCESS    not-accessible
 | 
						|
    STATUS        current
 | 
						|
    DESCRIPTION   "A list of entries for each FPC(Flexible PIC Concentrator)
 | 
						|
                   giving it's assigned priority and power being allocated. 
 | 
						|
                   More information on FPCs can be found in JUNIPER-MIB."
 | 
						|
    ::= { jnxPsuObjects 5 }
 | 
						|
 | 
						|
jnxPsuFpcPowerEntry OBJECT-TYPE
 | 
						|
    SYNTAX       JnxPsuFpcPowerEntry
 | 
						|
    MAX-ACCESS   not-accessible
 | 
						|
    STATUS       current
 | 
						|
    DESCRIPTION  "A value contained within the FpcPowerEntry"
 | 
						|
    INDEX        { jnxContentsContainerIndex,
 | 
						|
                   jnxContentsL1Index,
 | 
						|
                   jnxContentsL2Index,
 | 
						|
                   jnxContentsL3Index }
 | 
						|
     ::= { jnxPsuFpcPowerTable 1 }
 | 
						|
 | 
						|
JnxPsuFpcPowerEntry ::=
 | 
						|
    SEQUENCE {
 | 
						|
            jnxPsuFpcPowerPriority               INTEGER,
 | 
						|
            jnxPsuFpcPowerAllocated              INTEGER
 | 
						|
          }
 | 
						|
      
 | 
						|
jnxPsuFpcPowerPriority OBJECT-TYPE
 | 
						|
     SYNTAX         INTEGER
 | 
						|
     MAX-ACCESS     read-only
 | 
						|
     STATUS         current
 | 
						|
     DESCRIPTION    "The Power budget priority assigned to the FPC.
 | 
						|
                     Lower number means higher priority."
 | 
						|
     ::= { jnxPsuFpcPowerEntry 1 }
 | 
						|
 | 
						|
jnxPsuFpcPowerAllocated OBJECT-TYPE
 | 
						|
    SYNTAX         INTEGER
 | 
						|
    MAX-ACCESS     read-only
 | 
						|
    STATUS         current
 | 
						|
    DESCRIPTION    "The Power allocated to the FPC in Watts."
 | 
						|
    ::= { jnxPsuFpcPowerEntry 2 }
 | 
						|
 | 
						|
END
 |