1314 lines
		
	
	
		
			34 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			1314 lines
		
	
	
		
			34 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
UHP-MIB DEFINITIONS ::= BEGIN
 | 
						|
 | 
						|
IMPORTS
 | 
						|
	MODULE-IDENTITY, OBJECT-TYPE, IpAddress, Integer32, enterprises, Counter32, Gauge32
 | 
						|
		FROM SNMPv2-SMI
 | 
						|
	DisplayString
 | 
						|
		FROM SNMPv2-TC;
 | 
						|
 | 
						|
uhpV32	MODULE-IDENTITY
 | 
						|
		LAST-UPDATED	"201811021200Z"
 | 
						|
		ORGANIZATION	"UHP Networks"
 | 
						|
		CONTACT-INFO	"www.uhp.net"
 | 
						|
		DESCRIPTION	"UHP terminal MIB"
 | 
						|
		REVISION	"201810251200Z"
 | 
						|
		DESCRIPTION	"UHP terminal MIB"
 | 
						|
	::= { uhp 22 }
 | 
						|
 | 
						|
 | 
						|
 | 
						|
 | 
						|
 | 
						|
 | 
						|
uhp	OBJECT IDENTIFIER ::= { enterprises  8000 }
 | 
						|
control		OBJECT IDENTIFIER ::= { uhpV32   1 }
 | 
						|
demod1	    	OBJECT IDENTIFIER ::= { uhpV32   2 }
 | 
						|
demod2	    	OBJECT IDENTIFIER ::= { uhpV32   3 }
 | 
						|
modulator   	OBJECT IDENTIFIER ::= { uhpV32   4 }
 | 
						|
tdma		OBJECT IDENTIFIER ::= { uhpV32   5 }
 | 
						|
router		OBJECT IDENTIFIER ::= { uhpV32   6 }
 | 
						|
shaper		OBJECT IDENTIFIER ::= { uhpV32   7 }
 | 
						|
system		OBJECT IDENTIFIER ::= { uhpV32   8 }
 | 
						|
mobile		OBJECT IDENTIFIER ::= { uhpV32   9 }
 | 
						|
 | 
						|
-- Control
 | 
						|
 | 
						|
    saveConfig   OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER {
 | 
						|
            nosave(0),
 | 
						|
            save0(1),
 | 
						|
            save1(2),
 | 
						|
            save2(3),
 | 
						|
            save3(4)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Save current profile to EEPROM profile 0-3.
 | 
						|
	     Profile 0 is automativally loaded on restart by default."
 | 
						|
        ::= { control 1 }
 | 
						|
 | 
						|
    reboot   OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER {
 | 
						|
            noreboot(1),
 | 
						|
            reboot(2)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Reboot device immediately."
 | 
						|
        ::= { control 2 }
 | 
						|
 | 
						|
    command   OBJECT-TYPE
 | 
						|
        SYNTAX  DisplayString
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Issue a command to command-line interface."
 | 
						|
        ::= { control 3 }
 | 
						|
 | 
						|
    configEdit   OBJECT-TYPE
 | 
						|
        SYNTAX  DisplayString
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Profile or global config editing and viewing
 | 
						|
	     Complex input format, only for manufacturer."
 | 
						|
        ::= { control 4 }
 | 
						|
 | 
						|
    profile   OBJECT-TYPE
 | 
						|
        SYNTAX  DisplayString
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Get current profile or run specified profile (1-8)."
 | 
						|
        ::= { control 5 }
 | 
						|
 | 
						|
-- Demod1
 | 
						|
 | 
						|
    lbandSNR1  	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
        "Signal to noise ratio at L-band demodulator input
 | 
						|
	     measured in 0.1 dB units."
 | 
						|
        ::= { demod1 1 }
 | 
						|
 | 
						|
    lbandOffset1 OBJECT-TYPE
 | 
						|
        SYNTAX  Integer32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
        "Frequency offset value in KHz between PLL frequency and
 | 
						|
	     carrier real frequency."
 | 
						|
        ::= { demod1 2 }
 | 
						|
 | 
						|
    inLvl1  	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
        "Current input level x -10dBm"
 | 
						|
        ::= { demod1 3 }
 | 
						|
 | 
						|
    inBytes1	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Demodulator1 traffic in bytes
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { demod1 4 }
 | 
						|
 | 
						|
-- Demod2
 | 
						|
 | 
						|
    lbandSNR2  	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
        "Signal to noise ratio at L-band demodulator input
 | 
						|
	     measured in 0.1 dB units."
 | 
						|
        ::= { demod2 1 }
 | 
						|
 | 
						|
    lbandOffset2	OBJECT-TYPE
 | 
						|
        SYNTAX  Integer32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
        "Frequency offset value in KHz between PLL frequency and
 | 
						|
	     carrier real frequency."
 | 
						|
        ::= { demod2 2 }
 | 
						|
 | 
						|
    inLvl2  	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
        "Current input level x -10dBm"
 | 
						|
        ::= { demod2 3 }
 | 
						|
 | 
						|
    inBytes2	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Demodulator2 traffic in bytes
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { demod2 4 }
 | 
						|
 | 
						|
-- Modulator
 | 
						|
prioAll  OBJECT IDENTIFIER ::= { modulator   1 }
 | 
						|
    outBytesA	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator traffic in bytes
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioAll 1 }
 | 
						|
 | 
						|
    outPktsA	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator traffic in packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioAll 2 }
 | 
						|
 | 
						|
    dropsA	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator dropped packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioAll 3 }
 | 
						|
 | 
						|
    queueLenBA	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator queue length in bytes
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioAll 4 }
 | 
						|
 | 
						|
    queueLenPA	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator queue length in packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioAll 5 }
 | 
						|
 | 
						|
    numStations	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of stations per ACM channel
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioAll 6 }
 | 
						|
 | 
						|
prioP1  OBJECT IDENTIFIER ::= { modulator   2 }
 | 
						|
 | 
						|
	outBytesP1	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P1(Low) priority traffic in bytes
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP1 1 }
 | 
						|
	outPktsP1	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P1(Low) priority traffic in packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP1 2 }
 | 
						|
	dropsP1	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P1(Low) priority dropped packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP1 3 }
 | 
						|
	queueLenBP1	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P1(Low) priority queue length in bytes
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP1 4 }
 | 
						|
	queueLenPP1	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P1(Low) priority queue length in packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP1 5 }
 | 
						|
 | 
						|
prioP4  OBJECT IDENTIFIER ::= { modulator   3 }
 | 
						|
 | 
						|
	outBytesP4	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P4(Med) priority traffic in bytes 
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP4 1 }
 | 
						|
	outPktsP4	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P4(Med) priority traffic in packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP4 2 }
 | 
						|
	dropsP4	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P4(Med) priority dropped packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP4 3 }
 | 
						|
	queueLenBP4	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P4(Med) priority queue length in bytes
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP4 4 }
 | 
						|
	queueLenPP4	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P4(Med) priority queue length in packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP4 5 }
 | 
						|
 | 
						|
prioP7 OBJECT IDENTIFIER ::= { modulator   4 }
 | 
						|
 | 
						|
	outBytesP7	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P7(High) priority traffic in bytes
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP7 1 }
 | 
						|
	outPktsP7	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P7(High) priority traffic in packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP7 2 }
 | 
						|
	dropsP7	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P7(High) priority dropped packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP7 3 }
 | 
						|
	queueLenBP7	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P7(High) priority queue length in bytes
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP7 4 }
 | 
						|
	queueLenPP7	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P7(High) priority queue length in packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP7 5 }
 | 
						|
 | 
						|
prioCtrl OBJECT IDENTIFIER ::= { modulator   5 }
 | 
						|
 | 
						|
	outBytesC	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator control traffic in bytes
 | 
						|
        (index 1 only)"
 | 
						|
        ::= { prioCtrl 1 }
 | 
						|
	outPktsC	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator control traffic in packets
 | 
						|
        (index 1 only)"
 | 
						|
        ::= { prioCtrl 2 }
 | 
						|
 | 
						|
level OBJECT IDENTIFIER ::= { modulator   6 }
 | 
						|
 | 
						|
	txLevel	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current TX level x -10dBm"
 | 
						|
        ::= { level 1 }
 | 
						|
 | 
						|
	txLevelDelta	OBJECT-TYPE
 | 
						|
        SYNTAX  Integer32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current TX level delta from set level x -10dBm"
 | 
						|
        ::= { level 2 }
 | 
						|
 | 
						|
	txMaxLevel	OBJECT-TYPE
 | 
						|
        SYNTAX  Integer32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Max TLC level x -10dBm"
 | 
						|
        ::= { level 3 }
 | 
						|
 | 
						|
prioP2 OBJECT IDENTIFIER ::= { modulator   7 }
 | 
						|
 | 
						|
	outBytesP2	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P2 priority traffic in bytes
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP2 1 }
 | 
						|
	outPktsP2	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P2 priority traffic in packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP2 2 }
 | 
						|
	dropsP2	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P2 priority dropped packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP2 3 }
 | 
						|
	queueLenBP2	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P2 priority queue length in bytes
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP2 4 }
 | 
						|
	queueLenPP2	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P2 priority queue length in packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP2 5 }
 | 
						|
 | 
						|
prioP3 OBJECT IDENTIFIER ::= { modulator   8 }
 | 
						|
 | 
						|
	outBytesP3	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P3 priority traffic in bytes
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP3 1 }
 | 
						|
	outPktsP3	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P3 priority traffic in packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP3 2 }
 | 
						|
	dropsP3	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P3 priority dropped packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP3 3 }
 | 
						|
	queueLenBP3	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P3 priority queue length in bytes
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP3 4 }
 | 
						|
	queueLenPP3	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P3 priority queue length in packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP3 5 }
 | 
						|
 | 
						|
prioP5 OBJECT IDENTIFIER ::= { modulator   9 }
 | 
						|
 | 
						|
	outBytesP5	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P5 priority traffic in bytes
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP5 1 }
 | 
						|
	outPktsP5	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P5 priority traffic in packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP5 2 }
 | 
						|
	dropsP5	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P5 priority dropped packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP5 3 }
 | 
						|
	queueLenBP5	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P5 priority queue length in bytes
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP5 4 }
 | 
						|
	queueLenPP5	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P5 priority queue length in packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP5 5 }
 | 
						|
 | 
						|
prioP6 OBJECT IDENTIFIER ::= { modulator   10 }
 | 
						|
 | 
						|
	outBytesP6	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P6 priority traffic in bytes
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP6 1 }
 | 
						|
	outPktsP6	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P6 priority traffic in packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP6 2 }
 | 
						|
	dropsP6	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P6 priority dropped packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP6 3 }
 | 
						|
	queueLenBP6	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P6 priority queue length in bytes
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP6 4 }
 | 
						|
	queueLenPP6	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Modulator P6 priority queue length in packets
 | 
						|
        (indexed by ACM channel)"
 | 
						|
        ::= { prioP6 5 }
 | 
						|
 | 
						|
-- Router
 | 
						|
 | 
						|
    unroutedPkts  	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of packets, router couldn't route anywhere
 | 
						|
	     (though they could have been tunneled)."
 | 
						|
        ::= { router 1 }
 | 
						|
 | 
						|
    unroutedSource   OBJECT-TYPE
 | 
						|
        SYNTAX  IpAddress
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Last source IP address of unrouted packet."
 | 
						|
        ::= { router 2 }
 | 
						|
 | 
						|
    unroutedDest   OBJECT-TYPE
 | 
						|
        SYNTAX  IpAddress
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Last destination IP address of unrouted packet."
 | 
						|
        ::= { router 3 }
 | 
						|
 | 
						|
    outVlanBytes 	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of bytes, transmitted via VLAN.
 | 
						|
	     Requires index, which is VLAN number."
 | 
						|
        ::= { router 4 }
 | 
						|
 | 
						|
    inVlanBytes 	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of bytes, received via VLAN.
 | 
						|
	     Requires index, which is VLAN number."
 | 
						|
        ::= { router 5 }
 | 
						|
 | 
						|
    outSvlanBytes 	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of bytes, transmitted via SVLAN.
 | 
						|
	     Requires index, which is SVLAN number."
 | 
						|
        ::= { router 6 }
 | 
						|
 | 
						|
    inSvlanBytes 	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of bytes, received via SVLAN.
 | 
						|
	     Requires index, which is SVLAN number."
 | 
						|
        ::= { router 7 }
 | 
						|
 | 
						|
    inSvlanPackets OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of packets, received via SVLAN.
 | 
						|
	     Requires index, which is SVLAN number."
 | 
						|
        ::= { router 8 }
 | 
						|
 | 
						|
--  TDMA
 | 
						|
 | 
						|
tts		    OBJECT IDENTIFIER ::= { tdma   1 }
 | 
						|
inroute		OBJECT IDENTIFIER ::= { tdma   2 }
 | 
						|
server		OBJECT IDENTIFIER ::= { tdma   3 }
 | 
						|
remTable	OBJECT IDENTIFIER ::= { tdma   4 }
 | 
						|
station		OBJECT IDENTIFIER ::= { tdma   5 }
 | 
						|
 | 
						|
-- TTS
 | 
						|
 | 
						|
    tdelta 	OBJECT-TYPE
 | 
						|
        SYNTAX  Integer32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "HUB/Outroute - TTS value
 | 
						|
	    Inroute/remote - Timers delta between local station and hub
 | 
						|
	    In 10MHz ticks.
 | 
						|
		Developers only"
 | 
						|
        ::= { tts 1 }
 | 
						|
 | 
						|
    tdtConfidence OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "HUB/Outroute - TTS confidence value 0-64
 | 
						|
	    Inroute/remote - Tdelta confidence 0-64"
 | 
						|
        ::= { tts 2 }
 | 
						|
 | 
						|
    softErrors 	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of soft errors of TTS/Tdelta measurement algorithm.
 | 
						|
	    Soft errors mean current value is outside averaged window."
 | 
						|
        ::= { tts 3 }
 | 
						|
		
 | 
						|
	hardErrors 	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of hard errors of TTS/Tdelta measurement algorithm."
 | 
						|
        ::= { tts 4 }	
 | 
						|
 | 
						|
 | 
						|
    hubTTS 	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "HUB TTS value in 10MHz ticks"
 | 
						|
        ::= { tts 5 }
 | 
						|
 | 
						|
    hubTTSconfidence OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "HUB TTS confidence value 0-64. It is requested from remotes or inroutes"
 | 
						|
        ::= { tts 6 }
 | 
						|
 | 
						|
    remoteTTS 	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Remote TTS value with compensations in 10MHz ticks. Developers only"
 | 
						|
        ::= { tts 7 }
 | 
						|
 | 
						|
-- Inroute
 | 
						|
 | 
						|
    netState 	OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER {
 | 
						|
            off(0),
 | 
						|
            init(1),
 | 
						|
            noConfig(2),
 | 
						|
            useConfig(3),
 | 
						|
            redundant(4),
 | 
						|
            startRX(5),
 | 
						|
            cotmPointing(6),
 | 
						|
            startHubTX(7),
 | 
						|
            noRX(8),
 | 
						|
            identify(9),
 | 
						|
            getNetConfig(10),
 | 
						|
            calcDelays(11),
 | 
						|
            startTDMA(12),
 | 
						|
            startTX(13),
 | 
						|
            acquisition(14),
 | 
						|
            adjustment(15),
 | 
						|
            noStations(16),
 | 
						|
            operation(17)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Operation sequence level"
 | 
						|
        ::= { inroute 1 }
 | 
						|
 | 
						|
    frameDelay 	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Delay in frames between TX and RX processing. Developers only"
 | 
						|
        ::= { inroute 2 }
 | 
						|
 | 
						|
    sectionBW 	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Bandwidth in Bits/second of single slot in frame"
 | 
						|
        ::= { inroute 3 }
 | 
						|
 | 
						|
    netRequest 	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Sum of all requests of all stations (slots)"
 | 
						|
        ::= { inroute 4 }
 | 
						|
	
 | 
						|
    freeSlots 	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of free-allocated slots in current frame"
 | 
						|
        ::= { inroute 5 }
 | 
						|
 | 
						|
    netLoad 	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Network load in % (values, greater than 100% mean overload)"
 | 
						|
        ::= { inroute 6 }
 | 
						|
 | 
						|
-- Server
 | 
						|
 | 
						|
    serverStatus 	OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER {
 | 
						|
            off(0),
 | 
						|
            init(1),
 | 
						|
            noConfig(2),
 | 
						|
            useConfig(3),
 | 
						|
            redundant(4),
 | 
						|
            startRX(5),
 | 
						|
            cotmPointing(6),
 | 
						|
            startHubTX(7),
 | 
						|
            noRX(8),
 | 
						|
            identify(9),
 | 
						|
            getNetConfig(10),
 | 
						|
            calcDelays(11),
 | 
						|
            startTDMA(12),
 | 
						|
            startTX(13),
 | 
						|
            acquisition(14),
 | 
						|
            adjustment(15),
 | 
						|
            noStations(16),
 | 
						|
            operation(17)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Server reply status"
 | 
						|
        ::= { server 1 }
 | 
						|
 | 
						|
    frameDuration 	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Frame duration in 10M ticks"
 | 
						|
        ::= { server 2 }
 | 
						|
 | 
						|
-- Remotes statistics table ( No SNMP_NEXT, direct remotes 1-252 addressing by index)
 | 
						|
 | 
						|
    rxBytes 	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Summary number of bytes, received from this remote"
 | 
						|
        ::= { remTable 1 }
 | 
						|
 | 
						|
    p1Bytes 	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of P1(Low) priority bytes, received from this remote"
 | 
						|
        ::= { remTable 2 }
 | 
						|
 | 
						|
    p4Bytes 	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of P4(Med) priority bytes, received from this remote"
 | 
						|
        ::= { remTable 3 }
 | 
						|
 | 
						|
    p7Bytes 	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of P7(High) priority bytes, received from this remote"
 | 
						|
        ::= { remTable 4 }
 | 
						|
 | 
						|
    crcErrors 	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of CRC errors, during reception of this remote"
 | 
						|
        ::= { remTable 5 }
 | 
						|
 | 
						|
     carrierToNoise	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Receive carrier-to-noise ratio of this remote in 0.1 dB steps"
 | 
						|
        ::= { remTable 6 }
 | 
						|
 | 
						|
     freqOffset	OBJECT-TYPE
 | 
						|
        SYNTAX  Integer32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Receive Frequency offset of this remote in Hz"
 | 
						|
        ::= { remTable 7 }
 | 
						|
 | 
						|
     remRecvHub	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "How this remote receives the hub in 0.1 dB steps"
 | 
						|
        ::= { remTable 8 }
 | 
						|
 | 
						|
     linkState	OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER {
 | 
						|
            up(1),
 | 
						|
            down(2),
 | 
						|
            off(3)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Link state of this remote"
 | 
						|
        ::= { remTable 9 }
 | 
						|
 | 
						|
     lastHeard	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Time in seconds since last burst was received from remote. Developers only"
 | 
						|
        ::= { remTable 10 }
 | 
						|
 | 
						|
     downTimes	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "How many times remote changed state to DOWN"
 | 
						|
        ::= { remTable 11 }
 | 
						|
 | 
						|
     totalRequest	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current non-real-time + real-time request from remote"
 | 
						|
        ::= { remTable 12 }
 | 
						|
 | 
						|
     nrtRequest	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current non-real-time request from remote"
 | 
						|
        ::= { remTable 13 }
 | 
						|
 | 
						|
     rtmRequest	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current real-time request from remote"
 | 
						|
        ::= { remTable 14 }
 | 
						|
 | 
						|
     currentFP	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of sections, allocated in current frame plan for remote"
 | 
						|
        ::= { remTable 15 }
 | 
						|
 | 
						|
     txLvl	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current transmit level x -0.1 dBm (1:360 -> -0.1:-36 dBm)"
 | 
						|
        ::= { remTable 16 }
 | 
						|
 | 
						|
     faults	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Station faults bitmap: 1-service monitoring local warning (LWRN);2-service monitoring local alarm (LFLT);4-service monitoring network warning (NWRN);8-service monitoring network alarm (NFLT);0x10    system fault (SYST);0x20    reboot fault (REBT);0x40    LAN down (LAN);0x80    RX offset fault (OFFS);0x100   CRC errors (CRC);0x200   TLC fault (TLC)"
 | 
						|
        ::= { remTable 17 }
 | 
						|
 | 
						|
     p2Bytes 	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of P2 priority bytes, received from this remote"
 | 
						|
        ::= { remTable 18 }
 | 
						|
 | 
						|
     p3Bytes 	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of P3 priority bytes, received from this remote"
 | 
						|
        ::= { remTable 19 }
 | 
						|
 | 
						|
     p5Bytes 	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of P5 priority bytes, received from this remote"
 | 
						|
        ::= { remTable 20 }
 | 
						|
 | 
						|
     p6Bytes 	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Number of P6 priority bytes, received from this remote"
 | 
						|
        ::= { remTable 21 }
 | 
						|
 | 
						|
 | 
						|
-- Station data
 | 
						|
 | 
						|
    stationState OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER {
 | 
						|
	    off(0),
 | 
						|
            init(1),
 | 
						|
            noConfig(2),
 | 
						|
            useConfig(3),
 | 
						|
            redundant(4),
 | 
						|
            startRX(5),
 | 
						|
            cotmPointing(6),
 | 
						|
            startHubTX(7),
 | 
						|
            noRX(8),
 | 
						|
            identify(9),
 | 
						|
            getNetConfig(10),
 | 
						|
            calcDelays(11),
 | 
						|
            startTDMA(12),
 | 
						|
            startTX(13),
 | 
						|
            acquisition(14),
 | 
						|
            adjustment(15),
 | 
						|
            noStations(16),
 | 
						|
            operation(17)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Remote initialization sequence level"
 | 
						|
        ::= { station 1 }
 | 
						|
 | 
						|
     remnrtRequest	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Request for non-real-time bandwidth in sections"
 | 
						|
        ::= { station 2 }
 | 
						|
 | 
						|
     remrtRequest	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Request for real-time bandwidth in sections"
 | 
						|
        ::= { station 3 }
 | 
						|
 | 
						|
     fpLost	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Lost frame plans number"
 | 
						|
        ::= { station 4 }
 | 
						|
 | 
						|
     lvlOffset	OBJECT-TYPE
 | 
						|
        SYNTAX  Integer32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Offset between reference level and C/N level on hub. Developers only"
 | 
						|
        ::= { station 5 }
 | 
						|
 | 
						|
     lvlAdjust	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "TX power level adjustment value in 0.1 dB steps"
 | 
						|
        ::= { station 6 }
 | 
						|
 | 
						|
     frqOffset	OBJECT-TYPE
 | 
						|
        SYNTAX  Integer32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Frequency offset on hub. Developers only"
 | 
						|
        ::= { station 7 }
 | 
						|
 | 
						|
     frqAdjust	OBJECT-TYPE
 | 
						|
        SYNTAX  Integer32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "TX frequency adjustment value in Hz. Developers only"
 | 
						|
        ::= { station 8 }
 | 
						|
 | 
						|
     timeOffset	OBJECT-TYPE
 | 
						|
        SYNTAX  Integer32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Timing offset on hub in symbols"
 | 
						|
        ::= { station 9 }
 | 
						|
 | 
						|
     timeAdjust	OBJECT-TYPE
 | 
						|
        SYNTAX  Integer32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "TX timing adjustment value in 10M ticks"
 | 
						|
        ::= { station 10 }
 | 
						|
 | 
						|
-- Traffic Shaper stats  ( No SNMP_NEXT, direct stream 0-500 addressing by index)
 | 
						|
 | 
						|
	streamSpeed	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current speed in Kbits per second of current stream"
 | 
						|
        ::= { shaper 1 }
 | 
						|
 | 
						|
	streamP1Speed OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current speed in Kbits per second of P1(Low) priority sub-stream"
 | 
						|
        ::= { shaper 2 }
 | 
						|
 | 
						|
	streamP4Speed OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current speed in Kbits per second of P4(Med) priority sub-stream"
 | 
						|
        ::= { shaper 3 }
 | 
						|
 | 
						|
	streamP7Speed	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current speed in Kbits per second of P7(High) priority sub-stream"
 | 
						|
        ::= { shaper 4 }
 | 
						|
 | 
						|
	streamDelay	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current packets delay in stream x 0.1s"
 | 
						|
        ::= { shaper 5 }
 | 
						|
 | 
						|
	streamQueue	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current stream queue length in bytes"
 | 
						|
        ::= { shaper 6 }
 | 
						|
 | 
						|
	streamP2Speed	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current speed in Kbits per second of P2 priority sub-stream"
 | 
						|
        ::= { shaper 7 }
 | 
						|
 | 
						|
	streamP3Speed	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current speed in Kbits per second of P3 priority sub-stream"
 | 
						|
        ::= { shaper 8 }
 | 
						|
 | 
						|
	streamP5Speed	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current speed in Kbits per second of P5 priority sub-stream"
 | 
						|
        ::= { shaper 9 }
 | 
						|
 | 
						|
	streamP6Speed	OBJECT-TYPE
 | 
						|
        SYNTAX  Counter32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current speed in Kbits per second of P6 priority sub-stream"
 | 
						|
        ::= { shaper 10 }
 | 
						|
 | 
						|
-- System stats
 | 
						|
 | 
						|
	temperature	OBJECT-TYPE
 | 
						|
        SYNTAX  Integer32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current temperature"
 | 
						|
        ::= { system 1 }
 | 
						|
 | 
						|
	cpuLoad	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current CPU load in percent"
 | 
						|
        ::= { system 2 }
 | 
						|
 | 
						|
	buffers	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current buffers usage in percent"
 | 
						|
        ::= { system 3 }
 | 
						|
 | 
						|
	redundancy OBJECT-TYPE
 | 
						|
        SYNTAX  INTEGER {
 | 
						|
            idle(0),
 | 
						|
            backup(1),
 | 
						|
            faults(2),
 | 
						|
            trying(3),
 | 
						|
            active(4),
 | 
						|
            off(5)
 | 
						|
        }
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Current redundancy state"
 | 
						|
        ::= { system 4 }
 | 
						|
 | 
						|
	swVersion OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Software version. Four numbers of version contained in four bytes
 | 
						|
	     in order of precedence (see as hexadecimal)."
 | 
						|
        ::= { system 5 }
 | 
						|
 | 
						|
	releaseDate OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
	    "Release date. Two low bytes of number contain year,
 | 
						|
	     then month and day (see as hexadecimal)."
 | 
						|
        ::= { system 6 }
 | 
						|
 | 
						|
-- Mobile
 | 
						|
 | 
						|
    version OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
            "Software (protocol) version. Number 10 means V1.0"
 | 
						|
        ::= { mobile 1 }
 | 
						|
 | 
						|
    serialNumber	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
            "Serial number of this unit. If printed on the screen should be 
 | 
						|
	     printed as hexadecimal! Example - 4660 returned should be printed 
 | 
						|
	     as 1234 in hex."
 | 
						|
        ::= { mobile 2 }
 | 
						|
 | 
						|
    inputLevel  	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
            "Input baseband RF level in -0.1dBm steps. 500 means -50 dBm.
 | 
						|
	     Higher value means lower level. 800 (-80dBm) means no signal."
 | 
						|
        ::= { mobile 3 }
 | 
						|
 | 
						|
 | 
						|
    rxState	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-only
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
            "Composite value to provide controller with receive and overall state.
 | 
						|
	     0 means no RX lock.
 | 
						|
	     1 means absence of coordinates (send location data).
 | 
						|
	     2 means absence of TX status (send TX control command).
 | 
						|
	     3-250 means RX lock and shows demodulator C/N level in 0.1dBm 
 | 
						|
		steps (e.g. 100 means C/N=10 dB).
 | 
						|
	     Actual in all modes of operation. In SCPC/Star modes shows
 | 
						|
	     SCPC demodulator level, in FullMesh mode burst demodulator level."
 | 
						|
        ::= { mobile 4 }
 | 
						|
 | 
						|
 | 
						|
    searchState  	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
            "GET
 | 
						|
	     Value in percent (0-100) of current carrier search sequence.
 | 
						|
	     As search for narrow (<1Msps) carrier with high offset (DRO
 | 
						|
	     LNB) can last up-to 30 seconds, controller can wait until
 | 
						|
	     the whole acquisition bandwidth is scanned at least once.
 | 
						|
	     SET
 | 
						|
	     Writing any value restarts search cycle."
 | 
						|
        ::= { mobile 5 }
 | 
						|
 | 
						|
    txControl  	OBJECT-TYPE
 | 
						|
        SYNTAX  Gauge32
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
            "GET
 | 
						|
	     Current TX status (0-off, 1-on).
 | 
						|
	     SET
 | 
						|
	     Writing 0 turns TX off, 1 - turns on."
 | 
						|
        ::= { mobile 6 }
 | 
						|
 | 
						|
    location  	OBJECT-TYPE
 | 
						|
        SYNTAX  DisplayString
 | 
						|
        MAX-ACCESS  read-write
 | 
						|
        STATUS  current
 | 
						|
        DESCRIPTION
 | 
						|
            "GET
 | 
						|
	     Not applicable.
 | 
						|
	     SET
 | 
						|
	     NMEA RMC string
 | 
						|
	     $GPRMC,hhmmss.ss,A,GGMM.MM,P,gggmm.mm,J,v.v,b.b,ddmmyy,x.x,n,m*hh<CR><LF>
 | 
						|
	     Location should be re-supplied if changed more than 1 minute by any 	     coordinate."
 | 
						|
        ::= { mobile 7 }
 | 
						|
 | 
						|
END |