UHP-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, IpAddress, Integer32, enterprises, Counter32, Gauge32
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC;
uhpV32 MODULE-IDENTITY
LAST-UPDATED "201811021200Z"
ORGANIZATION "UHP Networks"
CONTACT-INFO "www.uhp.net"
DESCRIPTION "UHP terminal MIB"
REVISION "201810251200Z"
DESCRIPTION "UHP terminal MIB"
::= { uhp 22 }
uhp OBJECT IDENTIFIER ::= { enterprises 8000 }
control OBJECT IDENTIFIER ::= { uhpV32 1 }
demod1 OBJECT IDENTIFIER ::= { uhpV32 2 }
demod2 OBJECT IDENTIFIER ::= { uhpV32 3 }
modulator OBJECT IDENTIFIER ::= { uhpV32 4 }
tdma OBJECT IDENTIFIER ::= { uhpV32 5 }
router OBJECT IDENTIFIER ::= { uhpV32 6 }
shaper OBJECT IDENTIFIER ::= { uhpV32 7 }
system OBJECT IDENTIFIER ::= { uhpV32 8 }
mobile OBJECT IDENTIFIER ::= { uhpV32 9 }
-- Control
saveConfig OBJECT-TYPE
SYNTAX INTEGER {
nosave(0),
save0(1),
save1(2),
save2(3),
save3(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Save current profile to EEPROM profile 0-3.
Profile 0 is automativally loaded on restart by default."
::= { control 1 }
reboot OBJECT-TYPE
SYNTAX INTEGER {
noreboot(1),
reboot(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reboot device immediately."
::= { control 2 }
command OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Issue a command to command-line interface."
::= { control 3 }
configEdit OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile or global config editing and viewing
Complex input format, only for manufacturer."
::= { control 4 }
profile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Get current profile or run specified profile (1-8)."
::= { control 5 }
-- Demod1
lbandSNR1 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal to noise ratio at L-band demodulator input
measured in 0.1 dB units."
::= { demod1 1 }
lbandOffset1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frequency offset value in KHz between PLL frequency and
carrier real frequency."
::= { demod1 2 }
inLvl1 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current input level x -10dBm"
::= { demod1 3 }
inBytes1 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Demodulator1 traffic in bytes
(indexed by ACM channel)"
::= { demod1 4 }
-- Demod2
lbandSNR2 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal to noise ratio at L-band demodulator input
measured in 0.1 dB units."
::= { demod2 1 }
lbandOffset2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frequency offset value in KHz between PLL frequency and
carrier real frequency."
::= { demod2 2 }
inLvl2 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current input level x -10dBm"
::= { demod2 3 }
inBytes2 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Demodulator2 traffic in bytes
(indexed by ACM channel)"
::= { demod2 4 }
-- Modulator
prioAll OBJECT IDENTIFIER ::= { modulator 1 }
outBytesA OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator traffic in bytes
(indexed by ACM channel)"
::= { prioAll 1 }
outPktsA OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator traffic in packets
(indexed by ACM channel)"
::= { prioAll 2 }
dropsA OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator dropped packets
(indexed by ACM channel)"
::= { prioAll 3 }
queueLenBA OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator queue length in bytes
(indexed by ACM channel)"
::= { prioAll 4 }
queueLenPA OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator queue length in packets
(indexed by ACM channel)"
::= { prioAll 5 }
numStations OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of stations per ACM channel
(indexed by ACM channel)"
::= { prioAll 6 }
prioP1 OBJECT IDENTIFIER ::= { modulator 2 }
outBytesP1 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P1(Low) priority traffic in bytes
(indexed by ACM channel)"
::= { prioP1 1 }
outPktsP1 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P1(Low) priority traffic in packets
(indexed by ACM channel)"
::= { prioP1 2 }
dropsP1 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P1(Low) priority dropped packets
(indexed by ACM channel)"
::= { prioP1 3 }
queueLenBP1 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P1(Low) priority queue length in bytes
(indexed by ACM channel)"
::= { prioP1 4 }
queueLenPP1 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P1(Low) priority queue length in packets
(indexed by ACM channel)"
::= { prioP1 5 }
prioP4 OBJECT IDENTIFIER ::= { modulator 3 }
outBytesP4 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P4(Med) priority traffic in bytes
(indexed by ACM channel)"
::= { prioP4 1 }
outPktsP4 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P4(Med) priority traffic in packets
(indexed by ACM channel)"
::= { prioP4 2 }
dropsP4 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P4(Med) priority dropped packets
(indexed by ACM channel)"
::= { prioP4 3 }
queueLenBP4 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P4(Med) priority queue length in bytes
(indexed by ACM channel)"
::= { prioP4 4 }
queueLenPP4 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P4(Med) priority queue length in packets
(indexed by ACM channel)"
::= { prioP4 5 }
prioP7 OBJECT IDENTIFIER ::= { modulator 4 }
outBytesP7 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P7(High) priority traffic in bytes
(indexed by ACM channel)"
::= { prioP7 1 }
outPktsP7 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P7(High) priority traffic in packets
(indexed by ACM channel)"
::= { prioP7 2 }
dropsP7 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P7(High) priority dropped packets
(indexed by ACM channel)"
::= { prioP7 3 }
queueLenBP7 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P7(High) priority queue length in bytes
(indexed by ACM channel)"
::= { prioP7 4 }
queueLenPP7 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P7(High) priority queue length in packets
(indexed by ACM channel)"
::= { prioP7 5 }
prioCtrl OBJECT IDENTIFIER ::= { modulator 5 }
outBytesC OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator control traffic in bytes
(index 1 only)"
::= { prioCtrl 1 }
outPktsC OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator control traffic in packets
(index 1 only)"
::= { prioCtrl 2 }
level OBJECT IDENTIFIER ::= { modulator 6 }
txLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current TX level x -10dBm"
::= { level 1 }
txLevelDelta OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current TX level delta from set level x -10dBm"
::= { level 2 }
txMaxLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Max TLC level x -10dBm"
::= { level 3 }
prioP2 OBJECT IDENTIFIER ::= { modulator 7 }
outBytesP2 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P2 priority traffic in bytes
(indexed by ACM channel)"
::= { prioP2 1 }
outPktsP2 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P2 priority traffic in packets
(indexed by ACM channel)"
::= { prioP2 2 }
dropsP2 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P2 priority dropped packets
(indexed by ACM channel)"
::= { prioP2 3 }
queueLenBP2 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P2 priority queue length in bytes
(indexed by ACM channel)"
::= { prioP2 4 }
queueLenPP2 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P2 priority queue length in packets
(indexed by ACM channel)"
::= { prioP2 5 }
prioP3 OBJECT IDENTIFIER ::= { modulator 8 }
outBytesP3 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P3 priority traffic in bytes
(indexed by ACM channel)"
::= { prioP3 1 }
outPktsP3 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P3 priority traffic in packets
(indexed by ACM channel)"
::= { prioP3 2 }
dropsP3 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P3 priority dropped packets
(indexed by ACM channel)"
::= { prioP3 3 }
queueLenBP3 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P3 priority queue length in bytes
(indexed by ACM channel)"
::= { prioP3 4 }
queueLenPP3 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P3 priority queue length in packets
(indexed by ACM channel)"
::= { prioP3 5 }
prioP5 OBJECT IDENTIFIER ::= { modulator 9 }
outBytesP5 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P5 priority traffic in bytes
(indexed by ACM channel)"
::= { prioP5 1 }
outPktsP5 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P5 priority traffic in packets
(indexed by ACM channel)"
::= { prioP5 2 }
dropsP5 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P5 priority dropped packets
(indexed by ACM channel)"
::= { prioP5 3 }
queueLenBP5 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P5 priority queue length in bytes
(indexed by ACM channel)"
::= { prioP5 4 }
queueLenPP5 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P5 priority queue length in packets
(indexed by ACM channel)"
::= { prioP5 5 }
prioP6 OBJECT IDENTIFIER ::= { modulator 10 }
outBytesP6 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P6 priority traffic in bytes
(indexed by ACM channel)"
::= { prioP6 1 }
outPktsP6 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P6 priority traffic in packets
(indexed by ACM channel)"
::= { prioP6 2 }
dropsP6 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P6 priority dropped packets
(indexed by ACM channel)"
::= { prioP6 3 }
queueLenBP6 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P6 priority queue length in bytes
(indexed by ACM channel)"
::= { prioP6 4 }
queueLenPP6 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Modulator P6 priority queue length in packets
(indexed by ACM channel)"
::= { prioP6 5 }
-- Router
unroutedPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets, router couldn't route anywhere
(though they could have been tunneled)."
::= { router 1 }
unroutedSource OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last source IP address of unrouted packet."
::= { router 2 }
unroutedDest OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last destination IP address of unrouted packet."
::= { router 3 }
outVlanBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bytes, transmitted via VLAN.
Requires index, which is VLAN number."
::= { router 4 }
inVlanBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bytes, received via VLAN.
Requires index, which is VLAN number."
::= { router 5 }
outSvlanBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bytes, transmitted via SVLAN.
Requires index, which is SVLAN number."
::= { router 6 }
inSvlanBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bytes, received via SVLAN.
Requires index, which is SVLAN number."
::= { router 7 }
inSvlanPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets, received via SVLAN.
Requires index, which is SVLAN number."
::= { router 8 }
-- TDMA
tts OBJECT IDENTIFIER ::= { tdma 1 }
inroute OBJECT IDENTIFIER ::= { tdma 2 }
server OBJECT IDENTIFIER ::= { tdma 3 }
remTable OBJECT IDENTIFIER ::= { tdma 4 }
station OBJECT IDENTIFIER ::= { tdma 5 }
-- TTS
tdelta OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HUB/Outroute - TTS value
Inroute/remote - Timers delta between local station and hub
In 10MHz ticks.
Developers only"
::= { tts 1 }
tdtConfidence OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HUB/Outroute - TTS confidence value 0-64
Inroute/remote - Tdelta confidence 0-64"
::= { tts 2 }
softErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of soft errors of TTS/Tdelta measurement algorithm.
Soft errors mean current value is outside averaged window."
::= { tts 3 }
hardErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of hard errors of TTS/Tdelta measurement algorithm."
::= { tts 4 }
hubTTS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HUB TTS value in 10MHz ticks"
::= { tts 5 }
hubTTSconfidence OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HUB TTS confidence value 0-64. It is requested from remotes or inroutes"
::= { tts 6 }
remoteTTS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remote TTS value with compensations in 10MHz ticks. Developers only"
::= { tts 7 }
-- Inroute
netState OBJECT-TYPE
SYNTAX INTEGER {
off(0),
init(1),
noConfig(2),
useConfig(3),
redundant(4),
startRX(5),
cotmPointing(6),
startHubTX(7),
noRX(8),
identify(9),
getNetConfig(10),
calcDelays(11),
startTDMA(12),
startTX(13),
acquisition(14),
adjustment(15),
noStations(16),
operation(17)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operation sequence level"
::= { inroute 1 }
frameDelay OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Delay in frames between TX and RX processing. Developers only"
::= { inroute 2 }
sectionBW OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bandwidth in Bits/second of single slot in frame"
::= { inroute 3 }
netRequest OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sum of all requests of all stations (slots)"
::= { inroute 4 }
freeSlots OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of free-allocated slots in current frame"
::= { inroute 5 }
netLoad OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Network load in % (values, greater than 100% mean overload)"
::= { inroute 6 }
-- Server
serverStatus OBJECT-TYPE
SYNTAX INTEGER {
off(0),
init(1),
noConfig(2),
useConfig(3),
redundant(4),
startRX(5),
cotmPointing(6),
startHubTX(7),
noRX(8),
identify(9),
getNetConfig(10),
calcDelays(11),
startTDMA(12),
startTX(13),
acquisition(14),
adjustment(15),
noStations(16),
operation(17)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Server reply status"
::= { server 1 }
frameDuration OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frame duration in 10M ticks"
::= { server 2 }
-- Remotes statistics table ( No SNMP_NEXT, direct remotes 1-252 addressing by index)
rxBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Summary number of bytes, received from this remote"
::= { remTable 1 }
p1Bytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of P1(Low) priority bytes, received from this remote"
::= { remTable 2 }
p4Bytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of P4(Med) priority bytes, received from this remote"
::= { remTable 3 }
p7Bytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of P7(High) priority bytes, received from this remote"
::= { remTable 4 }
crcErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of CRC errors, during reception of this remote"
::= { remTable 5 }
carrierToNoise OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receive carrier-to-noise ratio of this remote in 0.1 dB steps"
::= { remTable 6 }
freqOffset OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receive Frequency offset of this remote in Hz"
::= { remTable 7 }
remRecvHub OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"How this remote receives the hub in 0.1 dB steps"
::= { remTable 8 }
linkState OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
off(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link state of this remote"
::= { remTable 9 }
lastHeard OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time in seconds since last burst was received from remote. Developers only"
::= { remTable 10 }
downTimes OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"How many times remote changed state to DOWN"
::= { remTable 11 }
totalRequest OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current non-real-time + real-time request from remote"
::= { remTable 12 }
nrtRequest OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current non-real-time request from remote"
::= { remTable 13 }
rtmRequest OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current real-time request from remote"
::= { remTable 14 }
currentFP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of sections, allocated in current frame plan for remote"
::= { remTable 15 }
txLvl OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current transmit level x -0.1 dBm (1:360 -> -0.1:-36 dBm)"
::= { remTable 16 }
faults OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Station faults bitmap: 1-service monitoring local warning (LWRN);2-service monitoring local alarm (LFLT);4-service monitoring network warning (NWRN);8-service monitoring network alarm (NFLT);0x10 system fault (SYST);0x20 reboot fault (REBT);0x40 LAN down (LAN);0x80 RX offset fault (OFFS);0x100 CRC errors (CRC);0x200 TLC fault (TLC)"
::= { remTable 17 }
p2Bytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of P2 priority bytes, received from this remote"
::= { remTable 18 }
p3Bytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of P3 priority bytes, received from this remote"
::= { remTable 19 }
p5Bytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of P5 priority bytes, received from this remote"
::= { remTable 20 }
p6Bytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of P6 priority bytes, received from this remote"
::= { remTable 21 }
-- Station data
stationState OBJECT-TYPE
SYNTAX INTEGER {
off(0),
init(1),
noConfig(2),
useConfig(3),
redundant(4),
startRX(5),
cotmPointing(6),
startHubTX(7),
noRX(8),
identify(9),
getNetConfig(10),
calcDelays(11),
startTDMA(12),
startTX(13),
acquisition(14),
adjustment(15),
noStations(16),
operation(17)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remote initialization sequence level"
::= { station 1 }
remnrtRequest OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Request for non-real-time bandwidth in sections"
::= { station 2 }
remrtRequest OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Request for real-time bandwidth in sections"
::= { station 3 }
fpLost OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lost frame plans number"
::= { station 4 }
lvlOffset OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Offset between reference level and C/N level on hub. Developers only"
::= { station 5 }
lvlAdjust OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TX power level adjustment value in 0.1 dB steps"
::= { station 6 }
frqOffset OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frequency offset on hub. Developers only"
::= { station 7 }
frqAdjust OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TX frequency adjustment value in Hz. Developers only"
::= { station 8 }
timeOffset OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timing offset on hub in symbols"
::= { station 9 }
timeAdjust OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TX timing adjustment value in 10M ticks"
::= { station 10 }
-- Traffic Shaper stats ( No SNMP_NEXT, direct stream 0-500 addressing by index)
streamSpeed OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current speed in Kbits per second of current stream"
::= { shaper 1 }
streamP1Speed OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current speed in Kbits per second of P1(Low) priority sub-stream"
::= { shaper 2 }
streamP4Speed OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current speed in Kbits per second of P4(Med) priority sub-stream"
::= { shaper 3 }
streamP7Speed OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current speed in Kbits per second of P7(High) priority sub-stream"
::= { shaper 4 }
streamDelay OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current packets delay in stream x 0.1s"
::= { shaper 5 }
streamQueue OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current stream queue length in bytes"
::= { shaper 6 }
streamP2Speed OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current speed in Kbits per second of P2 priority sub-stream"
::= { shaper 7 }
streamP3Speed OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current speed in Kbits per second of P3 priority sub-stream"
::= { shaper 8 }
streamP5Speed OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current speed in Kbits per second of P5 priority sub-stream"
::= { shaper 9 }
streamP6Speed OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current speed in Kbits per second of P6 priority sub-stream"
::= { shaper 10 }
-- System stats
temperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current temperature"
::= { system 1 }
cpuLoad OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current CPU load in percent"
::= { system 2 }
buffers OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current buffers usage in percent"
::= { system 3 }
redundancy OBJECT-TYPE
SYNTAX INTEGER {
idle(0),
backup(1),
faults(2),
trying(3),
active(4),
off(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current redundancy state"
::= { system 4 }
swVersion OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Software version. Four numbers of version contained in four bytes
in order of precedence (see as hexadecimal)."
::= { system 5 }
releaseDate OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Release date. Two low bytes of number contain year,
then month and day (see as hexadecimal)."
::= { system 6 }
-- Mobile
version OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Software (protocol) version. Number 10 means V1.0"
::= { mobile 1 }
serialNumber OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial number of this unit. If printed on the screen should be
printed as hexadecimal! Example - 4660 returned should be printed
as 1234 in hex."
::= { mobile 2 }
inputLevel OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Input baseband RF level in -0.1dBm steps. 500 means -50 dBm.
Higher value means lower level. 800 (-80dBm) means no signal."
::= { mobile 3 }
rxState OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Composite value to provide controller with receive and overall state.
0 means no RX lock.
1 means absence of coordinates (send location data).
2 means absence of TX status (send TX control command).
3-250 means RX lock and shows demodulator C/N level in 0.1dBm
steps (e.g. 100 means C/N=10 dB).
Actual in all modes of operation. In SCPC/Star modes shows
SCPC demodulator level, in FullMesh mode burst demodulator level."
::= { mobile 4 }
searchState OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"GET
Value in percent (0-100) of current carrier search sequence.
As search for narrow (<1Msps) carrier with high offset (DRO
LNB) can last up-to 30 seconds, controller can wait until
the whole acquisition bandwidth is scanned at least once.
SET
Writing any value restarts search cycle."
::= { mobile 5 }
txControl OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"GET
Current TX status (0-off, 1-on).
SET
Writing 0 turns TX off, 1 - turns on."
::= { mobile 6 }
location OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"GET
Not applicable.
SET
NMEA RMC string
$GPRMC,hhmmss.ss,A,GGMM.MM,P,gggmm.mm,J,v.v,b.b,ddmmyy,x.x,n,m*hh<CR><LF>
Location should be re-supplied if changed more than 1 minute by any coordinate."
::= { mobile 7 }
END