1314 lines
34 KiB
Plaintext
1314 lines
34 KiB
Plaintext
UHP-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, IpAddress, Integer32, enterprises, Counter32, Gauge32
|
|
FROM SNMPv2-SMI
|
|
DisplayString
|
|
FROM SNMPv2-TC;
|
|
|
|
uhpV32 MODULE-IDENTITY
|
|
LAST-UPDATED "201811021200Z"
|
|
ORGANIZATION "UHP Networks"
|
|
CONTACT-INFO "www.uhp.net"
|
|
DESCRIPTION "UHP terminal MIB"
|
|
REVISION "201810251200Z"
|
|
DESCRIPTION "UHP terminal MIB"
|
|
::= { uhp 22 }
|
|
|
|
|
|
|
|
|
|
|
|
|
|
uhp OBJECT IDENTIFIER ::= { enterprises 8000 }
|
|
control OBJECT IDENTIFIER ::= { uhpV32 1 }
|
|
demod1 OBJECT IDENTIFIER ::= { uhpV32 2 }
|
|
demod2 OBJECT IDENTIFIER ::= { uhpV32 3 }
|
|
modulator OBJECT IDENTIFIER ::= { uhpV32 4 }
|
|
tdma OBJECT IDENTIFIER ::= { uhpV32 5 }
|
|
router OBJECT IDENTIFIER ::= { uhpV32 6 }
|
|
shaper OBJECT IDENTIFIER ::= { uhpV32 7 }
|
|
system OBJECT IDENTIFIER ::= { uhpV32 8 }
|
|
mobile OBJECT IDENTIFIER ::= { uhpV32 9 }
|
|
|
|
-- Control
|
|
|
|
saveConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nosave(0),
|
|
save0(1),
|
|
save1(2),
|
|
save2(3),
|
|
save3(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Save current profile to EEPROM profile 0-3.
|
|
Profile 0 is automativally loaded on restart by default."
|
|
::= { control 1 }
|
|
|
|
reboot OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noreboot(1),
|
|
reboot(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reboot device immediately."
|
|
::= { control 2 }
|
|
|
|
command OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Issue a command to command-line interface."
|
|
::= { control 3 }
|
|
|
|
configEdit OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Profile or global config editing and viewing
|
|
Complex input format, only for manufacturer."
|
|
::= { control 4 }
|
|
|
|
profile OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Get current profile or run specified profile (1-8)."
|
|
::= { control 5 }
|
|
|
|
-- Demod1
|
|
|
|
lbandSNR1 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Signal to noise ratio at L-band demodulator input
|
|
measured in 0.1 dB units."
|
|
::= { demod1 1 }
|
|
|
|
lbandOffset1 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Frequency offset value in KHz between PLL frequency and
|
|
carrier real frequency."
|
|
::= { demod1 2 }
|
|
|
|
inLvl1 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current input level x -10dBm"
|
|
::= { demod1 3 }
|
|
|
|
inBytes1 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Demodulator1 traffic in bytes
|
|
(indexed by ACM channel)"
|
|
::= { demod1 4 }
|
|
|
|
-- Demod2
|
|
|
|
lbandSNR2 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Signal to noise ratio at L-band demodulator input
|
|
measured in 0.1 dB units."
|
|
::= { demod2 1 }
|
|
|
|
lbandOffset2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Frequency offset value in KHz between PLL frequency and
|
|
carrier real frequency."
|
|
::= { demod2 2 }
|
|
|
|
inLvl2 OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current input level x -10dBm"
|
|
::= { demod2 3 }
|
|
|
|
inBytes2 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Demodulator2 traffic in bytes
|
|
(indexed by ACM channel)"
|
|
::= { demod2 4 }
|
|
|
|
-- Modulator
|
|
prioAll OBJECT IDENTIFIER ::= { modulator 1 }
|
|
outBytesA OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator traffic in bytes
|
|
(indexed by ACM channel)"
|
|
::= { prioAll 1 }
|
|
|
|
outPktsA OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator traffic in packets
|
|
(indexed by ACM channel)"
|
|
::= { prioAll 2 }
|
|
|
|
dropsA OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator dropped packets
|
|
(indexed by ACM channel)"
|
|
::= { prioAll 3 }
|
|
|
|
queueLenBA OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator queue length in bytes
|
|
(indexed by ACM channel)"
|
|
::= { prioAll 4 }
|
|
|
|
queueLenPA OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator queue length in packets
|
|
(indexed by ACM channel)"
|
|
::= { prioAll 5 }
|
|
|
|
numStations OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of stations per ACM channel
|
|
(indexed by ACM channel)"
|
|
::= { prioAll 6 }
|
|
|
|
prioP1 OBJECT IDENTIFIER ::= { modulator 2 }
|
|
|
|
outBytesP1 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P1(Low) priority traffic in bytes
|
|
(indexed by ACM channel)"
|
|
::= { prioP1 1 }
|
|
outPktsP1 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P1(Low) priority traffic in packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP1 2 }
|
|
dropsP1 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P1(Low) priority dropped packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP1 3 }
|
|
queueLenBP1 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P1(Low) priority queue length in bytes
|
|
(indexed by ACM channel)"
|
|
::= { prioP1 4 }
|
|
queueLenPP1 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P1(Low) priority queue length in packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP1 5 }
|
|
|
|
prioP4 OBJECT IDENTIFIER ::= { modulator 3 }
|
|
|
|
outBytesP4 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P4(Med) priority traffic in bytes
|
|
(indexed by ACM channel)"
|
|
::= { prioP4 1 }
|
|
outPktsP4 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P4(Med) priority traffic in packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP4 2 }
|
|
dropsP4 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P4(Med) priority dropped packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP4 3 }
|
|
queueLenBP4 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P4(Med) priority queue length in bytes
|
|
(indexed by ACM channel)"
|
|
::= { prioP4 4 }
|
|
queueLenPP4 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P4(Med) priority queue length in packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP4 5 }
|
|
|
|
prioP7 OBJECT IDENTIFIER ::= { modulator 4 }
|
|
|
|
outBytesP7 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P7(High) priority traffic in bytes
|
|
(indexed by ACM channel)"
|
|
::= { prioP7 1 }
|
|
outPktsP7 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P7(High) priority traffic in packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP7 2 }
|
|
dropsP7 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P7(High) priority dropped packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP7 3 }
|
|
queueLenBP7 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P7(High) priority queue length in bytes
|
|
(indexed by ACM channel)"
|
|
::= { prioP7 4 }
|
|
queueLenPP7 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P7(High) priority queue length in packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP7 5 }
|
|
|
|
prioCtrl OBJECT IDENTIFIER ::= { modulator 5 }
|
|
|
|
outBytesC OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator control traffic in bytes
|
|
(index 1 only)"
|
|
::= { prioCtrl 1 }
|
|
outPktsC OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator control traffic in packets
|
|
(index 1 only)"
|
|
::= { prioCtrl 2 }
|
|
|
|
level OBJECT IDENTIFIER ::= { modulator 6 }
|
|
|
|
txLevel OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current TX level x -10dBm"
|
|
::= { level 1 }
|
|
|
|
txLevelDelta OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current TX level delta from set level x -10dBm"
|
|
::= { level 2 }
|
|
|
|
txMaxLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Max TLC level x -10dBm"
|
|
::= { level 3 }
|
|
|
|
prioP2 OBJECT IDENTIFIER ::= { modulator 7 }
|
|
|
|
outBytesP2 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P2 priority traffic in bytes
|
|
(indexed by ACM channel)"
|
|
::= { prioP2 1 }
|
|
outPktsP2 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P2 priority traffic in packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP2 2 }
|
|
dropsP2 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P2 priority dropped packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP2 3 }
|
|
queueLenBP2 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P2 priority queue length in bytes
|
|
(indexed by ACM channel)"
|
|
::= { prioP2 4 }
|
|
queueLenPP2 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P2 priority queue length in packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP2 5 }
|
|
|
|
prioP3 OBJECT IDENTIFIER ::= { modulator 8 }
|
|
|
|
outBytesP3 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P3 priority traffic in bytes
|
|
(indexed by ACM channel)"
|
|
::= { prioP3 1 }
|
|
outPktsP3 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P3 priority traffic in packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP3 2 }
|
|
dropsP3 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P3 priority dropped packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP3 3 }
|
|
queueLenBP3 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P3 priority queue length in bytes
|
|
(indexed by ACM channel)"
|
|
::= { prioP3 4 }
|
|
queueLenPP3 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P3 priority queue length in packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP3 5 }
|
|
|
|
prioP5 OBJECT IDENTIFIER ::= { modulator 9 }
|
|
|
|
outBytesP5 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P5 priority traffic in bytes
|
|
(indexed by ACM channel)"
|
|
::= { prioP5 1 }
|
|
outPktsP5 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P5 priority traffic in packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP5 2 }
|
|
dropsP5 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P5 priority dropped packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP5 3 }
|
|
queueLenBP5 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P5 priority queue length in bytes
|
|
(indexed by ACM channel)"
|
|
::= { prioP5 4 }
|
|
queueLenPP5 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P5 priority queue length in packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP5 5 }
|
|
|
|
prioP6 OBJECT IDENTIFIER ::= { modulator 10 }
|
|
|
|
outBytesP6 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P6 priority traffic in bytes
|
|
(indexed by ACM channel)"
|
|
::= { prioP6 1 }
|
|
outPktsP6 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P6 priority traffic in packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP6 2 }
|
|
dropsP6 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P6 priority dropped packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP6 3 }
|
|
queueLenBP6 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P6 priority queue length in bytes
|
|
(indexed by ACM channel)"
|
|
::= { prioP6 4 }
|
|
queueLenPP6 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modulator P6 priority queue length in packets
|
|
(indexed by ACM channel)"
|
|
::= { prioP6 5 }
|
|
|
|
-- Router
|
|
|
|
unroutedPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of packets, router couldn't route anywhere
|
|
(though they could have been tunneled)."
|
|
::= { router 1 }
|
|
|
|
unroutedSource OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Last source IP address of unrouted packet."
|
|
::= { router 2 }
|
|
|
|
unroutedDest OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Last destination IP address of unrouted packet."
|
|
::= { router 3 }
|
|
|
|
outVlanBytes OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of bytes, transmitted via VLAN.
|
|
Requires index, which is VLAN number."
|
|
::= { router 4 }
|
|
|
|
inVlanBytes OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of bytes, received via VLAN.
|
|
Requires index, which is VLAN number."
|
|
::= { router 5 }
|
|
|
|
outSvlanBytes OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of bytes, transmitted via SVLAN.
|
|
Requires index, which is SVLAN number."
|
|
::= { router 6 }
|
|
|
|
inSvlanBytes OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of bytes, received via SVLAN.
|
|
Requires index, which is SVLAN number."
|
|
::= { router 7 }
|
|
|
|
inSvlanPackets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of packets, received via SVLAN.
|
|
Requires index, which is SVLAN number."
|
|
::= { router 8 }
|
|
|
|
-- TDMA
|
|
|
|
tts OBJECT IDENTIFIER ::= { tdma 1 }
|
|
inroute OBJECT IDENTIFIER ::= { tdma 2 }
|
|
server OBJECT IDENTIFIER ::= { tdma 3 }
|
|
remTable OBJECT IDENTIFIER ::= { tdma 4 }
|
|
station OBJECT IDENTIFIER ::= { tdma 5 }
|
|
|
|
-- TTS
|
|
|
|
tdelta OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"HUB/Outroute - TTS value
|
|
Inroute/remote - Timers delta between local station and hub
|
|
In 10MHz ticks.
|
|
Developers only"
|
|
::= { tts 1 }
|
|
|
|
tdtConfidence OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"HUB/Outroute - TTS confidence value 0-64
|
|
Inroute/remote - Tdelta confidence 0-64"
|
|
::= { tts 2 }
|
|
|
|
softErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of soft errors of TTS/Tdelta measurement algorithm.
|
|
Soft errors mean current value is outside averaged window."
|
|
::= { tts 3 }
|
|
|
|
hardErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of hard errors of TTS/Tdelta measurement algorithm."
|
|
::= { tts 4 }
|
|
|
|
|
|
hubTTS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"HUB TTS value in 10MHz ticks"
|
|
::= { tts 5 }
|
|
|
|
hubTTSconfidence OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"HUB TTS confidence value 0-64. It is requested from remotes or inroutes"
|
|
::= { tts 6 }
|
|
|
|
remoteTTS OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote TTS value with compensations in 10MHz ticks. Developers only"
|
|
::= { tts 7 }
|
|
|
|
-- Inroute
|
|
|
|
netState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
init(1),
|
|
noConfig(2),
|
|
useConfig(3),
|
|
redundant(4),
|
|
startRX(5),
|
|
cotmPointing(6),
|
|
startHubTX(7),
|
|
noRX(8),
|
|
identify(9),
|
|
getNetConfig(10),
|
|
calcDelays(11),
|
|
startTDMA(12),
|
|
startTX(13),
|
|
acquisition(14),
|
|
adjustment(15),
|
|
noStations(16),
|
|
operation(17)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation sequence level"
|
|
::= { inroute 1 }
|
|
|
|
frameDelay OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Delay in frames between TX and RX processing. Developers only"
|
|
::= { inroute 2 }
|
|
|
|
sectionBW OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Bandwidth in Bits/second of single slot in frame"
|
|
::= { inroute 3 }
|
|
|
|
netRequest OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sum of all requests of all stations (slots)"
|
|
::= { inroute 4 }
|
|
|
|
freeSlots OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of free-allocated slots in current frame"
|
|
::= { inroute 5 }
|
|
|
|
netLoad OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network load in % (values, greater than 100% mean overload)"
|
|
::= { inroute 6 }
|
|
|
|
-- Server
|
|
|
|
serverStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
init(1),
|
|
noConfig(2),
|
|
useConfig(3),
|
|
redundant(4),
|
|
startRX(5),
|
|
cotmPointing(6),
|
|
startHubTX(7),
|
|
noRX(8),
|
|
identify(9),
|
|
getNetConfig(10),
|
|
calcDelays(11),
|
|
startTDMA(12),
|
|
startTX(13),
|
|
acquisition(14),
|
|
adjustment(15),
|
|
noStations(16),
|
|
operation(17)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Server reply status"
|
|
::= { server 1 }
|
|
|
|
frameDuration OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Frame duration in 10M ticks"
|
|
::= { server 2 }
|
|
|
|
-- Remotes statistics table ( No SNMP_NEXT, direct remotes 1-252 addressing by index)
|
|
|
|
rxBytes OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Summary number of bytes, received from this remote"
|
|
::= { remTable 1 }
|
|
|
|
p1Bytes OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of P1(Low) priority bytes, received from this remote"
|
|
::= { remTable 2 }
|
|
|
|
p4Bytes OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of P4(Med) priority bytes, received from this remote"
|
|
::= { remTable 3 }
|
|
|
|
p7Bytes OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of P7(High) priority bytes, received from this remote"
|
|
::= { remTable 4 }
|
|
|
|
crcErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of CRC errors, during reception of this remote"
|
|
::= { remTable 5 }
|
|
|
|
carrierToNoise OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Receive carrier-to-noise ratio of this remote in 0.1 dB steps"
|
|
::= { remTable 6 }
|
|
|
|
freqOffset OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Receive Frequency offset of this remote in Hz"
|
|
::= { remTable 7 }
|
|
|
|
remRecvHub OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"How this remote receives the hub in 0.1 dB steps"
|
|
::= { remTable 8 }
|
|
|
|
linkState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1),
|
|
down(2),
|
|
off(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Link state of this remote"
|
|
::= { remTable 9 }
|
|
|
|
lastHeard OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time in seconds since last burst was received from remote. Developers only"
|
|
::= { remTable 10 }
|
|
|
|
downTimes OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"How many times remote changed state to DOWN"
|
|
::= { remTable 11 }
|
|
|
|
totalRequest OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current non-real-time + real-time request from remote"
|
|
::= { remTable 12 }
|
|
|
|
nrtRequest OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current non-real-time request from remote"
|
|
::= { remTable 13 }
|
|
|
|
rtmRequest OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current real-time request from remote"
|
|
::= { remTable 14 }
|
|
|
|
currentFP OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sections, allocated in current frame plan for remote"
|
|
::= { remTable 15 }
|
|
|
|
txLvl OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current transmit level x -0.1 dBm (1:360 -> -0.1:-36 dBm)"
|
|
::= { remTable 16 }
|
|
|
|
faults OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Station faults bitmap: 1-service monitoring local warning (LWRN);2-service monitoring local alarm (LFLT);4-service monitoring network warning (NWRN);8-service monitoring network alarm (NFLT);0x10 system fault (SYST);0x20 reboot fault (REBT);0x40 LAN down (LAN);0x80 RX offset fault (OFFS);0x100 CRC errors (CRC);0x200 TLC fault (TLC)"
|
|
::= { remTable 17 }
|
|
|
|
p2Bytes OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of P2 priority bytes, received from this remote"
|
|
::= { remTable 18 }
|
|
|
|
p3Bytes OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of P3 priority bytes, received from this remote"
|
|
::= { remTable 19 }
|
|
|
|
p5Bytes OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of P5 priority bytes, received from this remote"
|
|
::= { remTable 20 }
|
|
|
|
p6Bytes OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of P6 priority bytes, received from this remote"
|
|
::= { remTable 21 }
|
|
|
|
|
|
-- Station data
|
|
|
|
stationState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
init(1),
|
|
noConfig(2),
|
|
useConfig(3),
|
|
redundant(4),
|
|
startRX(5),
|
|
cotmPointing(6),
|
|
startHubTX(7),
|
|
noRX(8),
|
|
identify(9),
|
|
getNetConfig(10),
|
|
calcDelays(11),
|
|
startTDMA(12),
|
|
startTX(13),
|
|
acquisition(14),
|
|
adjustment(15),
|
|
noStations(16),
|
|
operation(17)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote initialization sequence level"
|
|
::= { station 1 }
|
|
|
|
remnrtRequest OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Request for non-real-time bandwidth in sections"
|
|
::= { station 2 }
|
|
|
|
remrtRequest OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Request for real-time bandwidth in sections"
|
|
::= { station 3 }
|
|
|
|
fpLost OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Lost frame plans number"
|
|
::= { station 4 }
|
|
|
|
lvlOffset OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Offset between reference level and C/N level on hub. Developers only"
|
|
::= { station 5 }
|
|
|
|
lvlAdjust OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TX power level adjustment value in 0.1 dB steps"
|
|
::= { station 6 }
|
|
|
|
frqOffset OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Frequency offset on hub. Developers only"
|
|
::= { station 7 }
|
|
|
|
frqAdjust OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TX frequency adjustment value in Hz. Developers only"
|
|
::= { station 8 }
|
|
|
|
timeOffset OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timing offset on hub in symbols"
|
|
::= { station 9 }
|
|
|
|
timeAdjust OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TX timing adjustment value in 10M ticks"
|
|
::= { station 10 }
|
|
|
|
-- Traffic Shaper stats ( No SNMP_NEXT, direct stream 0-500 addressing by index)
|
|
|
|
streamSpeed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current speed in Kbits per second of current stream"
|
|
::= { shaper 1 }
|
|
|
|
streamP1Speed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current speed in Kbits per second of P1(Low) priority sub-stream"
|
|
::= { shaper 2 }
|
|
|
|
streamP4Speed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current speed in Kbits per second of P4(Med) priority sub-stream"
|
|
::= { shaper 3 }
|
|
|
|
streamP7Speed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current speed in Kbits per second of P7(High) priority sub-stream"
|
|
::= { shaper 4 }
|
|
|
|
streamDelay OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current packets delay in stream x 0.1s"
|
|
::= { shaper 5 }
|
|
|
|
streamQueue OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current stream queue length in bytes"
|
|
::= { shaper 6 }
|
|
|
|
streamP2Speed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current speed in Kbits per second of P2 priority sub-stream"
|
|
::= { shaper 7 }
|
|
|
|
streamP3Speed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current speed in Kbits per second of P3 priority sub-stream"
|
|
::= { shaper 8 }
|
|
|
|
streamP5Speed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current speed in Kbits per second of P5 priority sub-stream"
|
|
::= { shaper 9 }
|
|
|
|
streamP6Speed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current speed in Kbits per second of P6 priority sub-stream"
|
|
::= { shaper 10 }
|
|
|
|
-- System stats
|
|
|
|
temperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current temperature"
|
|
::= { system 1 }
|
|
|
|
cpuLoad OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current CPU load in percent"
|
|
::= { system 2 }
|
|
|
|
buffers OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current buffers usage in percent"
|
|
::= { system 3 }
|
|
|
|
redundancy OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
idle(0),
|
|
backup(1),
|
|
faults(2),
|
|
trying(3),
|
|
active(4),
|
|
off(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current redundancy state"
|
|
::= { system 4 }
|
|
|
|
swVersion OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Software version. Four numbers of version contained in four bytes
|
|
in order of precedence (see as hexadecimal)."
|
|
::= { system 5 }
|
|
|
|
releaseDate OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Release date. Two low bytes of number contain year,
|
|
then month and day (see as hexadecimal)."
|
|
::= { system 6 }
|
|
|
|
-- Mobile
|
|
|
|
version OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Software (protocol) version. Number 10 means V1.0"
|
|
::= { mobile 1 }
|
|
|
|
serialNumber OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial number of this unit. If printed on the screen should be
|
|
printed as hexadecimal! Example - 4660 returned should be printed
|
|
as 1234 in hex."
|
|
::= { mobile 2 }
|
|
|
|
inputLevel OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input baseband RF level in -0.1dBm steps. 500 means -50 dBm.
|
|
Higher value means lower level. 800 (-80dBm) means no signal."
|
|
::= { mobile 3 }
|
|
|
|
|
|
rxState OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Composite value to provide controller with receive and overall state.
|
|
0 means no RX lock.
|
|
1 means absence of coordinates (send location data).
|
|
2 means absence of TX status (send TX control command).
|
|
3-250 means RX lock and shows demodulator C/N level in 0.1dBm
|
|
steps (e.g. 100 means C/N=10 dB).
|
|
Actual in all modes of operation. In SCPC/Star modes shows
|
|
SCPC demodulator level, in FullMesh mode burst demodulator level."
|
|
::= { mobile 4 }
|
|
|
|
|
|
searchState OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"GET
|
|
Value in percent (0-100) of current carrier search sequence.
|
|
As search for narrow (<1Msps) carrier with high offset (DRO
|
|
LNB) can last up-to 30 seconds, controller can wait until
|
|
the whole acquisition bandwidth is scanned at least once.
|
|
SET
|
|
Writing any value restarts search cycle."
|
|
::= { mobile 5 }
|
|
|
|
txControl OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"GET
|
|
Current TX status (0-off, 1-on).
|
|
SET
|
|
Writing 0 turns TX off, 1 - turns on."
|
|
::= { mobile 6 }
|
|
|
|
location OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"GET
|
|
Not applicable.
|
|
SET
|
|
NMEA RMC string
|
|
$GPRMC,hhmmss.ss,A,GGMM.MM,P,gggmm.mm,J,v.v,b.b,ddmmyy,x.x,n,m*hh<CR><LF>
|
|
Location should be re-supplied if changed more than 1 minute by any coordinate."
|
|
::= { mobile 7 }
|
|
|
|
END |