mibs/MIBS/DOCS-IF-MIB
2023-12-05 12:25:34 +01:00

4047 lines
161 KiB
Plaintext

DOCS-IF-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
-- do not import BITS,
Unsigned32,
Integer32,
Counter32,
Counter64,
TimeTicks,
IpAddress,
transmission
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
MacAddress,
RowStatus,
TruthValue,
TimeInterval,
TimeStamp
FROM SNMPv2-TC
OBJECT-GROUP,
MODULE-COMPLIANCE
FROM SNMPv2-CONF
ifIndex, InterfaceIndexOrZero
FROM IF-MIB
InetAddressType,
InetAddress
FROM INET-ADDRESS-MIB
IANAifType
FROM IANAifType-MIB;
docsIfMib MODULE-IDENTITY
LAST-UPDATED "200212200000Z" -- December 20, 2002
ORGANIZATION "IETF IPCDN Working Group"
CONTACT-INFO
" David Raftus
Postal: Imedia Semiconductor
340 Terry Fox Drive, Suite 202
Ottawa Ontario
Canada
Phone: +1 613 592 1052 ext.222
E-mail: david.raftus@imedia.com
IETF IPCDN Working Group
General Discussion: ipcdn@ietf.org
Subscribe: http://www.ietf.org/mailman/listinfo/ipcdn
Archive: ftp://ftp.ietf.org/ietf-mail-archive/ipcdn
Co-chairs: Richard Woundy, RWoundy@broadband.att.com
Jean-Francois Mule, jf.mule@cablelabs.com"
DESCRIPTION
"This is the MIB Module for DOCSIS 2.0 compliant Radio
Frequency (RF) interfaces in Cable Modems (CM) and
Cable Modem Termination Systems (CMTS)."
REVISION "200212200000Z"
DESCRIPTION
"pre-RFC draft v5:
Modified by David Raftus to add channel utilization related objects,
upstream channel equalization related objects, a cmts upstream minislot
counter table, a cmts downstream byte counter table, 64 bit versions of
existing 32 bit docsIfSigQTable objects, and perform some editorial
adjustments.
pre-RFC draft v4:
Modified by David Raftus to fix docsIfUpChannelWidth range
in compliance statements to accommodate 6.4Mhz channel at
5.12 Msymbol/sec. Also adjusted description of
docsIfUpChannelStatus to use correct rowStatus terminology.
pre-RFC draft v3:
Modified by David Raftus to add new textual convention
describing upstream modulation status. Also clarified
some object descriptions, fixed error in
docsIfSignalQualityEntry, fixed upstreamTable compliance
statements.
pre-RFC draft v2:
Modified by David Raftus to add capability to adjust
and verify upstream channel parameters as a group.
Also adjusted syntax and clarified descriptions of
selected objects.
pre-RFC draft v1:
Modified by Aviv Goren and David Raftus to accommodate
Docsis 2.0 Advanced Phy capabilities, as well as to
incorporate objects from the docsIfExt mib.
Modified by Rich Woundy to use IPv6-friendly
address objects, to accommodate EuroDOCSIS, and
to correct the SYNTAX of various objects."
REVISION "199908190000Z"
DESCRIPTION
"Initial Version, published as RFC 2670.
Modified by Mike StJohns to fix problems identified by
the first pass of the MIB doctor. Of special note,
docsIfRangingResp and docsIfCmtsInsertionInterval were
obsoleted and replaced by other objects with the same
functionality, but more appropriate SYNTAX."
::= { transmission 127 }
-- Textual Conventions
TenthdBmV ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-1"
STATUS current
DESCRIPTION
"This data type represents power levels that are normally
expressed in dBmV. Units are in tenths of a dBmV;
for example, 5.1 dBmV will be represented as 51."
SYNTAX Integer32
TenthdB ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-1"
STATUS current
DESCRIPTION
"This data type represents power levels that are normally
expressed in dB. Units are in tenths of a dB;
for example, 5.1 dB will be represented as 51."
SYNTAX Integer32
DocsisVersion ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Indicates the DOCSIS version number."
SYNTAX INTEGER {
docsis10 (1),
docsis11 (2),
docsis20 (3)
}
DocsisQosVersion ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Indicates the quality of service level."
SYNTAX INTEGER {
docsis10 (1),
docsis11 (2)
}
DocsisUpstreamType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Indicates the DOCSIS Upstream Channel Type."
SYNTAX INTEGER {
unknown (0),
tdma (1),
atdma (2),
scdma (3),
tdmaAndAtdma (4)
}
DocsisUpstreamTypeStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Indicates the DOCSIS Upstream Channel Type Status.
The shared channel indicator type is not valid, since
this type is used to specifically identify PHY mode."
SYNTAX INTEGER {
unknown (0),
tdma (1),
atdma (2),
scdma (3)
}
docsIfMibObjects OBJECT IDENTIFIER ::= { docsIfMib 1 }
docsIfBaseObjects OBJECT IDENTIFIER ::= { docsIfMibObjects 1 }
docsIfCmObjects OBJECT IDENTIFIER ::= { docsIfMibObjects 2 }
docsIfCmtsObjects OBJECT IDENTIFIER ::= { docsIfMibObjects 3 }
--
-- BASE GROUP
--
--
-- The following table is implemented on both the Cable Modem (CM)
-- and the Cable Modem Termination System (CMTS). This table is
-- read only for the CM.
--
docsIfDownstreamChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfDownstreamChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes the attributes of downstream
channels (frequency bands)."
REFERENCE
"Document [25] from References, Table 6-12 and Table 6-13."
::= { docsIfBaseObjects 1 }
docsIfDownstreamChannelEntry OBJECT-TYPE
SYNTAX DocsIfDownstreamChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry provides a list of attributes for a single
Downstream channel.
An entry in this table exists for each ifEntry with an
ifType of docsCableDownstream(128)."
INDEX { ifIndex }
::= { docsIfDownstreamChannelTable 1 }
DocsIfDownstreamChannelEntry ::= SEQUENCE {
docsIfDownChannelId Integer32,
docsIfDownChannelFrequency Integer32,
docsIfDownChannelWidth Integer32,
docsIfDownChannelModulation INTEGER,
docsIfDownChannelInterleave INTEGER,
docsIfDownChannelPower TenthdBmV,
docsIfDownChannelAnnex INTEGER
}
docsIfDownChannelId OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Cable Modem Termination System (CMTS) identification
of the downstream channel within this particular MAC
interface. If the interface is down, the object returns
the most current value. If the downstream channel ID is
unknown, this object returns a value of 0."
::= { docsIfDownstreamChannelEntry 1 }
docsIfDownChannelFrequency OBJECT-TYPE
SYNTAX Integer32 (0..1000000000)
UNITS "hertz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The center of the downstream frequency associated with
this channel. This object will return the current tuner
frequency. If a CMTS provides IF output, this object
will return 0, unless this CMTS is in control of the
final downstream RF frequency. See the associated
compliance object for a description of valid frequencies
that may be written to this object."
REFERENCE
"Document [25] from References, Tables 4-1, 6-14."
::= { docsIfDownstreamChannelEntry 2 }
docsIfDownChannelWidth OBJECT-TYPE
SYNTAX Integer32 (0..16000000)
UNITS "hertz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The bandwidth of this downstream channel. Most
implementations are expected to support a channel width
of 6 MHz (North America) and/or 8 MHz (Europe). See the
associated compliance object for a description of the
valid channel widths for this object."
REFERENCE
"Document [25] from References, Table 6-14."
::= { docsIfDownstreamChannelEntry 3 }
docsIfDownChannelModulation OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
qam64(3),
qam256(4),
qam512(5),
qam1024(6),
qpsk(7),
qam16(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The modulation type associated with this downstream
channel. If the interface is down, this object either
returns the configured value (CMTS), the most current
value (CM), or the value of unknown(1). See the
associated conformance object for write conditions and
limitations. See the reference for specifics on the
modulation profiles implied by qam64 and qam256."
REFERENCE
"Document [25] from References, Table 6-14."
::= { docsIfDownstreamChannelEntry 4 }
docsIfDownChannelInterleave OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
taps8Increment16(3),
taps16Increment8(4),
taps32Increment4(5),
taps64Increment2(6),
taps128Increment1(7),
taps12increment17(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Forward Error Correction (FEC) interleaving used
for this downstream channel.
Values are defined as follows:
taps8Increment16(3): protection 5.9/4.1 usec,
latency .22/.15 msec
taps16Increment8(4): protection 12/8.2 usec,
latency .48/.33 msec
taps32Increment4(5): protection 24/16 usec,
latency .98/.68 msec
taps64Increment2(6): protection 47/33 usec,
latency 2/1.4 msec
taps128Increment1(7): protection 95/66 usec,
latency 4/2.8 msec
taps12increment17(8): protection 18/14 usec,
latency 0.43/0.32 msec
taps12increment17 is implemented in
conformance with EuroDOCSIS document
'Adapted MIB-definitions - and a
clarification for MPEG-related issues - for
EuroDOCSIS cable modem systems' by tComLabs
and should only be used for a EuroDOCSIS MAC
interface.
If the interface is down, this object either returns
the configured value (CMTS), the most current value (CM),
or the value of unknown(1).
The value of other(2) is returned if the interleave
is known but not defined in the above list.
See the associated conformance object for write
conditions and limitations. See the reference for the FEC
configuration described by the setting of this object."
REFERENCE
"Document [25] from References, Table 6-13."
::= { docsIfDownstreamChannelEntry 5 }
docsIfDownChannelPower OBJECT-TYPE
SYNTAX TenthdBmV
UNITS "dBmV"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"At the CMTS, the operational transmit power. At the CM,
the received power level. May be set to zero at the CM
if power level measurement is not supported.
If the interface is down, this object either returns
the configured value (CMTS), the most current value (CM)
or the value of 0. See the associated conformance object
for write conditions and limitations. See the reference
for recommended and required power levels."
REFERENCE
"Document [25] from References,Table 6-15."
::= { docsIfDownstreamChannelEntry 6 }
docsIfDownChannelAnnex OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
annexA(3),
annexB(4),
annexC(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object indicates the conformance of
the implementation to important regional cable standards.
annexA : Annex A from ITU-J83 is used.
annexB : Annex B from ITU-J83 is used.
annexC : Annex C from ITU-J83 is used.
AnnexB is used for DOCSIS implementations"
REFERENCE
"Document [28] from References, Section 2.2"
::= { docsIfDownstreamChannelEntry 7 }
--
-- The following table is implemented on both the CM and the CMTS.
-- For the CM, only attached channels appear in the table. For the
-- CM, this table is read only as well.
--
docsIfUpstreamChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfUpstreamChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes the attributes of attached upstream
channels."
::= { docsIfBaseObjects 2 }
docsIfUpstreamChannelEntry OBJECT-TYPE
SYNTAX DocsIfUpstreamChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of attributes for a single upstream channel. For
Docsis 2.0 CMTSs, an entry in this table exists for
each ifEntry with an ifType of docsCableUpstreamChannel (205).
For Docsis 1.x CM/CMTSs and Docsis 2.0 CMs, an entry in this table exists
for each ifEntry with an ifType of docsCableUpstreamInterface (129)."
INDEX { ifIndex }
::= { docsIfUpstreamChannelTable 1 }
DocsIfUpstreamChannelEntry ::= SEQUENCE {
docsIfUpChannelId Integer32,
docsIfUpChannelFrequency Integer32,
docsIfUpChannelWidth Integer32,
docsIfUpChannelModulationProfile Unsigned32,
docsIfUpChannelSlotSize Unsigned32,
docsIfUpChannelTxTimingOffset Unsigned32,
docsIfUpChannelRangingBackoffStart Integer32,
docsIfUpChannelRangingBackoffEnd Integer32,
docsIfUpChannelTxBackoffStart Integer32,
docsIfUpChannelTxBackoffEnd Integer32,
docsIfUpChannelScdmaActiveCodes Unsigned32,
docsIfUpChannelScdmaCodesPerSlot Integer32,
docsIfUpChannelScdmaFrameSize Unsigned32,
docsIfUpChannelScdmaHoppingSeed Unsigned32,
docsIfUpChannelType DocsisUpstreamType,
docsIfUpChannelCloneFrom InterfaceIndexOrZero,
docsIfUpChannelUpdate TruthValue,
docsIfUpChannelStatus RowStatus,
docsIfUpChannelPreEqEnable TruthValue
}
docsIfUpChannelId OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CMTS identification of the upstream channel."
::= { docsIfUpstreamChannelEntry 1 }
docsIfUpChannelFrequency OBJECT-TYPE
SYNTAX Integer32 (0..1000000000)
UNITS "hertz"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The center of the frequency band associated with this
upstream interface. This object returns 0 if the frequency
is undefined or unknown. Minimum permitted upstream
frequency is 5,000,000 Hz for current technology. See
the associated conformance object for write conditions
and limitations."
REFERENCE
"Document [25] from References, Table 4-2."
::= { docsIfUpstreamChannelEntry 2 }
docsIfUpChannelWidth OBJECT-TYPE
SYNTAX Integer32 (0..64000000)
UNITS "hertz"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The bandwidth of this upstream interface. This object
returns 0 if the interface width is undefined or unknown.
Minimum permitted interface width is 200,000 Hz currently.
See the associated conformance object for write conditions
and limitations."
REFERENCE
"Document [25] from References, Table 6-12."
::= { docsIfUpstreamChannelEntry 3 }
docsIfUpChannelModulationProfile OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An entry identical to the docsIfModIndex in the
docsIfCmtsModulationTable that describes this channel.
This channel is further instantiated there by a grouping
of interval usage codes which together fully describe the
channel modulation. This object returns 0 if the
docsIfCmtsModulationTable entry does not exist or
docsIfCmtsModulationTable is empty. See
the associated conformance object for write conditions
and limitations."
REFERENCE
"Document [25] from References, Table 8-19."
::= { docsIfUpstreamChannelEntry 4 }
docsIfUpChannelSlotSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Applicable to TDMA and ATDMA channel types only.
The number of 6.25 microsecond ticks in each upstream mini-
slot. Returns zero if the value is undefined, unknown or in
case of an SCDMA channel.
See the associated conformance object for write
conditions and limitations. "
REFERENCE
"Document [25] from References, Section 8.1.2.4."
::= { docsIfUpstreamChannelEntry 5 }
docsIfUpChannelTxTimingOffset OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"At the CM, a measure of the current round trip time obtained from the
ranging offset (initial ranging offset + ranging offset adjustments).
At the CMTS, the maximum of timing offset, among all the CMs that
are/were present on the channel, taking into account all ( initial +
periodic )timing offset corrections that were sent for each of the CMs.
Generally, these measurements are positive, but if the
measurements are negative, the value of this object is zero. Used for
timing of CM upstream transmissions to ensure synchronized arrivals at
the CMTS. Units are in terms of (6.25 microseconds/64)."
REFERENCE
"Document [25] from References, Section 6.2.18."
::= { docsIfUpstreamChannelEntry 6 }
docsIfUpChannelRangingBackoffStart OBJECT-TYPE
SYNTAX Integer32 (0..16)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The initial random backoff window to use when retrying
Ranging Requests. Expressed as a power of 2. A value of 16
at the CMTS indicates that a proprietary adaptive retry
mechanism is to be used. See the associated conformance
object for write conditions and limitations."
REFERENCE
"Document [25] from References, Section 8.3.4."
::= { docsIfUpstreamChannelEntry 7 }
docsIfUpChannelRangingBackoffEnd OBJECT-TYPE
SYNTAX Integer32 (0..16)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The final random backoff window to use when retrying
Ranging Requests. Expressed as a power of 2. A value of 16
at the CMTS indicates that a proprietary adaptive retry
mechanism is to be used. See the associated conformance
object for write conditions and limitations."
REFERENCE
"Document [25] from References, Section 8.3.4."
::= { docsIfUpstreamChannelEntry 8 }
docsIfUpChannelTxBackoffStart OBJECT-TYPE
SYNTAX Integer32 (0..16)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The initial random backoff window to use when retrying
transmissions. Expressed as a power of 2. A value of 16
at the CMTS indicates that a proprietary adaptive retry
mechanism is to be used. See the associated conformance
object for write conditions and limitations."
REFERENCE
"Document [25] from References, Section 8.3.4."
::= { docsIfUpstreamChannelEntry 9 }
docsIfUpChannelTxBackoffEnd OBJECT-TYPE
SYNTAX Integer32 (0..16)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The final random backoff window to use when retrying
transmissions. Expressed as a power of 2. A value of 16
at the CMTS indicates that a proprietary adaptive retry
mechanism is to be used. See the associated conformance
object for write conditions and limitations."
REFERENCE
"Document [25] from References, Section 8.3.4."
::= { docsIfUpstreamChannelEntry 10 }
docsIfUpChannelScdmaActiveCodes OBJECT-TYPE
SYNTAX Unsigned32 (0 | 64..128)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Applicable for SCDMA channel types only.
Number of active codes. Returns zero for
Non-SCDMA channel types. Note that legal
values from 64..128 MUST be non-prime."
REFERENCE
"Document [25] from References, Section 6.2.11.2.1."
::= { docsIfUpstreamChannelEntry 11 }
docsIfUpChannelScdmaCodesPerSlot OBJECT-TYPE
SYNTAX Integer32(0 | 2..32)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Applicable for SCDMA channel types only.
The number of SCDMA codes per mini-slot.
Returns zero if the value is undefined, unknown or in
case of a TDMA or ATDMA channel."
REFERENCE
"Document [25] from References, Section 6.2.11.2.1."
::= { docsIfUpstreamChannelEntry 12 }
docsIfUpChannelScdmaFrameSize OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Applicable for SCDMA channel types only.
SCDMA Frame size in units of spreading intervals.
This value returns zero for non SCDMA Profiles."
REFERENCE
" Document [25] from References, Section 6.2.12."
::= { docsIfUpstreamChannelEntry 13 }
docsIfUpChannelScdmaHoppingSeed OBJECT-TYPE
SYNTAX Unsigned32 (0..32767)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Applicable for SCDMA channel types only.
15 bit seed used for code hopping sequence initialization.
Returns zero for non-SCDMA channel types."
REFERENCE
"Document [25] from References, Section 6.2.14.1."
::= { docsIfUpstreamChannelEntry 14 }
docsIfUpChannelType OBJECT-TYPE
SYNTAX DocsisUpstreamType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Defines the Upstream channel type.
Given the channel type, other channel attributes can be checked
for value validity at the time of entry creation and update."
REFERENCE
"Document [25] from References, Section 6.2.1."
::= { docsIfUpstreamChannelEntry 15 }
docsIfUpChannelCloneFrom OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Intended for use when a temporary inactive upstream table row is
created for the purpose of manipulating SCDMA parameters for an
active row. Refer to the descriptions of docsIfUpChannelStatus
and docsIfUpChannelUpdate for details of this procedure.
This object contains the ifIndex value of the active upstream
row whose SCDMA parameters are to be adjusted.
Although this object was created to facilitate SCDMA parameter
adjustment, it may also be used at the vendor's discretion for
non-SCDMA parameter adjustment.
This object must contain a value of zero for active upstream rows."
::= { docsIfUpstreamChannelEntry 16 }
docsIfUpChannelUpdate OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Used to perform the transfer of adjusted SCDMA parameters from the
temporary upstream row to the active upstream row indicated by the
docsIfUpChannelCloneFrom object. The transfer is initiated through
an SNMP SET of TRUE to this object. The SNMP SET will fail with a
GEN_ERROR (snmpv1) or COMMIT_FAILED_ERROR (snmpv2c/v3) if the adjusted
SCDMA parameter values are not compatible with each other.
Although this object was created to facilitate SCDMA parameter
adjustment, it may also be used at the vendor's discretion for
non-SCDMA parameter adjustment.
An SNMP GET of this object always returns FALSE."
::= { docsIfUpstreamChannelEntry 17 }
docsIfUpChannelStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is generally intended to be used for the creation of
a temporary inactive upstream row for the purpose of adjusting
the SCDMA channel parameters of an active upstream row.
The recommended procedure is:
1) Create an inactive row through an SNMP SET using createAndWait(5).
Use an ifIndex value outside the operational range of the system.
2) Set the docsIfUpChannelCloneFrom field to the ifIndex value of
the active row whose SCDMA parameters require adjustment.
3) Adjust the SCDMA parameter values using the new temporary inactive
row.
4) Update the active row by setting object docsIfUpChannelUpdate to
TRUE. This SET will fail if the adjusted SCDMA parameters are not
compatible with each other.
5) Delete the temporary row through an SNMP SET using DELETE.
The following restrictions apply to this object:
1) This object must contain a value of active(1) for active rows.
2) Temporary inactive rows must be created using createAndWait(5).
3) The only possible status change of a row created using
createAndWait(5) (ie notInService(2)) is to destroy(6).
These temporary rows must never become active.
4) A status transition from active (1) to destroy (6) is not
permitted. Entries with docsIfUpChannelStatus set to active(1)
are logically linked to a physical interface, not temporarily
created to clone parameters. The Interface MIB (RFC 2863)
ifAdminStatus should be used to take an Upstream Channel offline.
Although this object was created to facilitate SCDMA parameter
adjustment, it may also be used at the vendor's discretion for
non-SCDMA parameter adjustment."
::= { docsIfUpstreamChannelEntry 18 }
docsIfUpChannelPreEqEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"At the CMTS, used to enable or disable pre-equalization on the
upstream channel represented by this table instance.
At the CM, this object is read-only and reflects the status of
pre-equalization as represented in the RNG-RSP."
::= { docsIfUpstreamChannelEntry 19 }
-- The following table describes the attributes of each class of
-- service. The entries in this table are referenced from the
-- docsIfServiceEntries. They exist as a separate table in order to
-- reduce redundant information in docsIfServiceTable.
--
-- This table is implemented at both the CM and the CMTS.
-- The CM need only maintain entries for the classes of service
-- referenced by its docsIfServiceTable.
--
docsIfQosProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfQosProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the attributes for each class of service."
::= { docsIfBaseObjects 3 }
docsIfQosProfileEntry OBJECT-TYPE
SYNTAX DocsIfQosProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the attributes for a single class of service.
If implemented as read-create in the Cable Modem
Termination System, creation of entries in this table is
controlled by the value of docsIfCmtsQosProfilePermissions.
If implemented as read-only, entries are created based
on information in REG-REQ MAC messages received from
Cable Modems (Cable Modem Termination System
implementation), or based on information extracted from
the TFTP option file (Cable Modem implementation).
In the Cable Modem Termination system, read-only entries
are removed if no longer referenced by
docsIfCmtsServiceTable.
An entry in this table must not be removed while it is
referenced by an entry in docsIfCmServiceTable (Cable Modem)
or docsIfCmtsServiceTable (Cable Modem Termination System).
An entry in this table should not be changeable while
it is referenced by an entry in docsIfCmtsServiceTable.
If this table is created automatically, there should only
be a single entry for each Class of Service. Multiple
entries with the same Class of Service parameters are not
recommended."
INDEX { docsIfQosProfIndex }
::= { docsIfQosProfileTable 1 }
DocsIfQosProfileEntry ::= SEQUENCE {
docsIfQosProfIndex Integer32,
docsIfQosProfPriority Integer32,
docsIfQosProfMaxUpBandwidth Integer32,
docsIfQosProfGuarUpBandwidth Integer32,
docsIfQosProfMaxDownBandwidth Integer32,
docsIfQosProfMaxTxBurst Integer32, -- Deprecated
docsIfQosProfBaselinePrivacy TruthValue,
docsIfQosProfStatus RowStatus,
docsIfQosProfMaxTransmitBurst Integer32
}
docsIfQosProfIndex OBJECT-TYPE
SYNTAX Integer32 (1..16383)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index value that uniquely identifies an entry
in the docsIfQosProfileTable."
::= { docsIfQosProfileEntry 1 }
docsIfQosProfPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A relative priority assigned to this service when
allocating bandwidth. Zero indicates lowest priority
and seven indicates highest priority.
Interpretation of priority is device-specific.
MUST NOT be changed while this row is active."
REFERENCE
"Document [25] from References, Appendix C.1.1.4."
DEFVAL { 0 }
::= { docsIfQosProfileEntry 2 }
docsIfQosProfMaxUpBandwidth OBJECT-TYPE
SYNTAX Integer32 (0..100000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum upstream bandwidth, in bits per second,
allowed for a service with this service class.
Zero if there is no restriction of upstream bandwidth.
MUST NOT be changed while this row is active."
REFERENCE
"Document [25] from References, Appendix C.1.1.4."
DEFVAL { 0 }
::= { docsIfQosProfileEntry 3 }
docsIfQosProfGuarUpBandwidth OBJECT-TYPE
SYNTAX Integer32 (0..100000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum guaranteed upstream bandwidth, in bits per second,
allowed for a service with this service class.
MUST NOT be changed while this row is active."
REFERENCE
"Document [25] from References, Appendix C.1.1.4."
DEFVAL { 0 }
::= { docsIfQosProfileEntry 4 }
docsIfQosProfMaxDownBandwidth OBJECT-TYPE
SYNTAX Integer32 (0..100000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum downstream bandwidth, in bits per second,
allowed for a service with this service class.
Zero if there is no restriction of downstream bandwidth.
MUST NOT be changed while this row is active."
REFERENCE
"Document [25] from References, Appendix C.1.1.4."
DEFVAL { 0 }
::= { docsIfQosProfileEntry 5 }
docsIfQosProfMaxTxBurst OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The maximum number of mini-slots that may be requested
for a single upstream transmission.
A value of zero means there is no limit.
MUST NOT be changed while this row is active.
This object has been deprecated and replaced by
docsIfQosProfMaxTransmitBurst, to fix a mismatch
of the units and value range with respect to the DOCSIS
Maximum Upstream Channel Transmit Burst Configuration
Setting."
REFERENCE
"Document [25] from References, C.1.1.4."
DEFVAL { 0 }
::= { docsIfQosProfileEntry 6 }
docsIfQosProfBaselinePrivacy OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether Baseline Privacy is enabled for this
service class.
MUST NOT be changed while this row is active."
DEFVAL { false }
::= { docsIfQosProfileEntry 7 }
docsIfQosProfStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is object is to used to create or delete rows in
this table. This object MUST NOT be changed from active
while the row is referenced by the any entry in either
docsIfCmServiceTable (on the CM), or the
docsIfCmtsServiceTable (on the CMTS)."
::= { docsIfQosProfileEntry 8 }
docsIfQosProfMaxTransmitBurst OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of bytes that may be requested for a
single upstream transmission. A value of zero means there
is no limit. Note: This value does not include any
physical layer overhead.
MUST NOT be changed while this row is active."
REFERENCE
"Document [25] from References, Appendix C.1.1.4."
DEFVAL { 0 }
::= { docsIfQosProfileEntry 9 }
docsIfSignalQualityTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfSignalQualityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"At the CM, describes the PHY signal quality of downstream
channels. At the CMTS, describes the PHY signal quality of
upstream channels. At the CMTS, this table may exclude
contention intervals."
::= { docsIfBaseObjects 4 }
docsIfSignalQualityEntry OBJECT-TYPE
SYNTAX DocsIfSignalQualityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"At the CM, describes the PHY characteristics of a
downstream channel. At the CMTS, describes the PHY signal
quality of an upstream channel.
An entry in this table exists for each ifEntry with an
ifType of docsCableUpstreamChannel(205) for Cable Modem Termination
Systems and docsCableDownstream(128) for Cable Modems."
INDEX { ifIndex }
::= { docsIfSignalQualityTable 1 }
DocsIfSignalQualityEntry ::= SEQUENCE {
docsIfSigQIncludesContention TruthValue,
docsIfSigQUnerroreds Counter32,
docsIfSigQCorrecteds Counter32,
docsIfSigQUncorrectables Counter32,
docsIfSigQSignalNoise TenthdB,
docsIfSigQMicroreflections Integer32,
docsIfSigQEqualizationData OCTET STRING,
docsIfSigQExtUnerroreds Counter64,
docsIfSigQExtCorrecteds Counter64,
docsIfSigQExtUncorrectables Counter64
}
docsIfSigQIncludesContention OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"true(1) if this CMTS includes contention intervals in
the counters in this table. Always false(2) for CMs."
REFERENCE
"Document [25] from References,
Section 9.4.1"
::= { docsIfSignalQualityEntry 1 }
docsIfSigQUnerroreds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codewords received on this channel without error.
This includes all codewords, whether or not they
were part of frames destined for this device."
REFERENCE
"Document [25] from References, Section 6.2.5."
::= { docsIfSignalQualityEntry 2 }
docsIfSigQCorrecteds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codewords received on this channel with correctable
errors. This includes all codewords, whether or not
they were part of frames destined for this device."
REFERENCE
"Document [25] from References, Section 6.2.5."
::= { docsIfSignalQualityEntry 3 }
docsIfSigQUncorrectables OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codewords received on this channel with uncorrectable
errors. This includes all codewords, whether or not
they were part of frames destined for this device."
REFERENCE
"Document [25] from References, Section 6.2.5."
::= { docsIfSignalQualityEntry 4 }
docsIfSigQSignalNoise OBJECT-TYPE
SYNTAX TenthdB
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal/Noise ratio as perceived for this channel.
At the CM, describes the Signal/Noise of the downstream
channel. At the CMTS, describes the average Signal/Noise
of the upstream channel."
REFERENCE
"Document [25] from References, Tables 4-1 and 4-2"
::= { docsIfSignalQualityEntry 5 }
docsIfSigQMicroreflections OBJECT-TYPE
SYNTAX Integer32 (0..255)
UNITS "dBc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total microreflections including in-channel response
as perceived on this interface, measured in dBc below
the signal level.
This object is not assumed to return an absolutely
accurate value, but should give a rough indication
of microreflections received on this interface.
It is up to the implementer to provide information
as accurate as possible."
REFERENCE
"Document [25] from References, Tables 4-1 and 4-2"
::= { docsIfSignalQualityEntry 6 }
docsIfSigQEqualizationData OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"At the CM, returns the equalization data for the downstream
channel. At the CMTS, returns the average equalization
data for the upstream channel. Returns an empty string
if the value is unknown or if there is no equalization
data available or defined."
REFERENCE
"Document [25] from References, Table 8-21."
::= { docsIfSignalQualityEntry 7 }
docsIfSigQExtUnerroreds OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codewords received on this channel without error.
This includes all codewords, whether or not they
were part of frames destined for this device.
This is the 64 bit version of docsIfSigQUnerroreds."
REFERENCE
"Document [25] from References, Section 6.2.5."
::= { docsIfSignalQualityEntry 8 }
docsIfSigQExtCorrecteds OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codewords received on this channel with correctable
errors. This includes all codewords, whether or not
they were part of frames destined for this device.
This is the 64 bit version of docsIfSigQCorrecteds."
REFERENCE
"Document [25] from References, Section 6.2.5."
::= { docsIfSignalQualityEntry 9 }
docsIfSigQExtUncorrectables OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codewords received on this channel with uncorrectable
errors. This includes all codewords, whether or not
they were part of frames destined for this device.
This is the 64 bit version of docsIfSigQUncorrectables."
REFERENCE
"Document [25] from References, Section 6.2.5."
::= { docsIfSignalQualityEntry 10 }
--
-- DOCSIS Version of the device
--
docsIfDocsisBaseCapability OBJECT-TYPE
SYNTAX DocsisVersion
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indication of the DOCSIS capability of the device.
This object mirrors docsIfDocsisCapability from the
DocsIfExt mib."
REFERENCE
"Document [25] from References, Annex G."
::= { docsIfBaseObjects 5 }
--
-- CABLE MODEM GROUP
--
-- #######
--
-- The CM MAC Table
--
docsIfCmMacTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the attributes of each CM MAC interface,
extending the information available from ifEntry."
::= { docsIfCmObjects 1 }
docsIfCmMacEntry OBJECT-TYPE
SYNTAX DocsIfCmMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing objects describing attributes of
each MAC entry, extending the information in ifEntry.
An entry in this table exists for each ifEntry with an
ifType of docsCableMaclayer(127)."
INDEX { ifIndex }
::= { docsIfCmMacTable 1 }
DocsIfCmMacEntry ::= SEQUENCE {
docsIfCmCmtsAddress MacAddress,
docsIfCmCapabilities BITS,
docsIfCmRangingRespTimeout TimeTicks,
docsIfCmRangingTimeout TimeInterval
}
docsIfCmCmtsAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the CMTS that is believed to control this MAC
domain. At the CM, this will be the source address from
SYNC, MAP, and other MAC-layer messages. If the CMTS is
unknown, returns 00-00-00-00-00-00."
REFERENCE
"Document [25] from References, Section 8.2.2."
::= { docsIfCmMacEntry 1 }
docsIfCmCapabilities OBJECT-TYPE
SYNTAX BITS {
atmCells(0),
concatenation(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the capabilities of the MAC implementation
at this interface. Note that packet transmission is
always supported. Therefore, there is no specific bit
required to explicitly indicate this capability.
Note that BITS objects are encoded most significant bit
first. For example, if bit 1 is set, the value of this
object is the octet string '40'H."
::= { docsIfCmMacEntry 2 }
-- This object has been obsoleted and replaced by
-- docsIfCmRangingTimeout to correct the typing to TimeInterval. New
-- implementations of the MIB should use docsIfCmRangingTimeout instead.
docsIfCmRangingRespTimeout OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Waiting time for a Ranging Response packet."
REFERENCE
"Document [25] from References, Section 9.1.6."
DEFVAL { 20 }
::= { docsIfCmMacEntry 3 }
docsIfCmRangingTimeout OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Waiting time for a Ranging Response packet."
REFERENCE
"Document [25] from References,
Section 9.1.6, timer T3."
DEFVAL { 20 }
::= { docsIfCmMacEntry 4 }
--
-- CM status table.
-- This table is implemented only at the CM.
--
docsIfCmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table maintains a number of status objects
and counters for Cable Modems."
::= { docsIfCmObjects 2 }
docsIfCmStatusEntry OBJECT-TYPE
SYNTAX DocsIfCmStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of status objects and counters for a single MAC
layer instance in a Cable Modem.
An entry in this table exists for each ifEntry with an
ifType of docsCableMaclayer(127)."
INDEX { ifIndex }
::= { docsIfCmStatusTable 1 }
DocsIfCmStatusEntry ::= SEQUENCE {
docsIfCmStatusValue INTEGER,
docsIfCmStatusCode OCTET STRING,
docsIfCmStatusTxPower TenthdBmV,
docsIfCmStatusResets Counter32,
docsIfCmStatusLostSyncs Counter32,
docsIfCmStatusInvalidMaps Counter32,
docsIfCmStatusInvalidUcds Counter32,
docsIfCmStatusInvalidRangingResponses Counter32,
docsIfCmStatusInvalidRegistrationResponses Counter32,
docsIfCmStatusT1Timeouts Counter32,
docsIfCmStatusT2Timeouts Counter32,
docsIfCmStatusT3Timeouts Counter32,
docsIfCmStatusT4Timeouts Counter32,
docsIfCmStatusRangingAborteds Counter32,
docsIfCmStatusDocsisOperMode DocsisQosVersion,
docsIfCmStatusModulationType DocsisUpstreamTypeStatus,
docsIfCmStatusEqualizationData OCTET STRING
}
docsIfCmStatusValue OBJECT-TYPE
SYNTAX INTEGER {
other(1),
notReady(2),
notSynchronized(3),
phySynchronized(4),
usParametersAcquired(5),
rangingComplete(6),
ipComplete(7),
todEstablished(8),
securityEstablished(9),
paramTransferComplete(10),
registrationComplete(11),
operational(12),
accessDenied(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Cable Modem connectivity state, as specified
in the RF Interface Specification. Interpretations for
state values 1-12 are clearly outlined in the Document [25]
reference given below.
As stated in the description for object docsIfCmtsCmStatusValue,
accessDenied(13)indicates the CMTS has sent a Registration
Aborted message to the CM."
REFERENCE
"Document [25] from References, Section 11.2.
Document [26] from References, Section 6.3.4.2."
::= { docsIfCmStatusEntry 1 }
docsIfCmStatusCode OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status code for this Cable Modem as defined in the
RF Interface Specification. The status code consists
of a single character indicating error groups, followed
by a two- or three-digit number indicating the status
condition."
REFERENCE
"Document [26] from References, Appendix F."
::= { docsIfCmStatusEntry 2 }
docsIfCmStatusTxPower OBJECT-TYPE
SYNTAX TenthdBmV
UNITS "dBmV"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational transmit power for the attached upstream
channel."
REFERENCE
"Document [25] from References, Section 6.2.18."
::= { docsIfCmStatusEntry 3 }
docsIfCmStatusResets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times the CM reset or initialized this interface."
::= { docsIfCmStatusEntry 4 }
docsIfCmStatusLostSyncs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times the CM lost synchronization with
the downstream channel."
REFERENCE
"Document [25] from References, Section 8.3.2."
::= { docsIfCmStatusEntry 5 }
docsIfCmStatusInvalidMaps OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times the CM received invalid MAP messages."
REFERENCE
"Document [25] from References, Section 8.3.4."
::= { docsIfCmStatusEntry 6 }
docsIfCmStatusInvalidUcds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times the CM received invalid UCD messages."
REFERENCE
"Document [25] from References, Section 8.3.3."
::= { docsIfCmStatusEntry 7 }
docsIfCmStatusInvalidRangingResponses OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times the CM received invalid ranging response
messages."
REFERENCE
"Document [25] from References, Section 8.3.6."
::= { docsIfCmStatusEntry 8 }
docsIfCmStatusInvalidRegistrationResponses OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times the CM received invalid registration
response messages."
REFERENCE
"Document [25] from References, Section 8.3.8."
::= { docsIfCmStatusEntry 9 }
docsIfCmStatusT1Timeouts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times counter T1 expired in the CM."
REFERENCE
"Document [25] from References, Figure 9-2."
::= { docsIfCmStatusEntry 10 }
docsIfCmStatusT2Timeouts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times counter T2 expired in the CM."
REFERENCE
"Document [25] from References, Figure 9-2."
::= { docsIfCmStatusEntry 11 }
docsIfCmStatusT3Timeouts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times counter T3 expired in the CM."
REFERENCE
"Document [25] from References, Figure 9-2."
::= { docsIfCmStatusEntry 12 }
docsIfCmStatusT4Timeouts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times counter T4 expired in the CM."
REFERENCE
"Document [25] from References, Figure 9-2."
::= { docsIfCmStatusEntry 13 }
docsIfCmStatusRangingAborteds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times the ranging process was aborted
by the CMTS."
REFERENCE
"Document [25] from References, Section 9.3.3."
::= { docsIfCmStatusEntry 14 }
docsIfCmStatusDocsisOperMode OBJECT-TYPE
SYNTAX DocsisQosVersion
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indication whether the device has registered using 1.0 Class of
Service or 1.1 Quality of Service.
An unregistered CM should indicate 1.1 QOS for a
docsIfDocsisBaseCapability value of Docsis 1.1/2.0. An unregistered
CM should indicate 1.0 COS for a docsIfDocsisBaseCapability value
of Docsis 1.0.
This object mirrors docsIfCmDocsisOperMode from the docsIfExt mib."
REFERENCE
"Document [25] from References, Annex G."
::= { docsIfCmStatusEntry 15 }
docsIfCmStatusModulationType OBJECT-TYPE
SYNTAX DocsisUpstreamTypeStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates modulation type status currently used by the CM.
Since this object specifically identifies PHY mode, the shared
upstream channel type is not permitted."
REFERENCE
"Document [25] from References, Section 6.2.1."
::= { docsIfCmStatusEntry 16 }
docsIfCmStatusEqualizationData OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pre-equalization data for this CM after convolution with
data indicated in the RNG-RSP.
Returns an empty string if the value is unknown or if there
is no equalization data available or defined. The value should
be formatted as defined in the following REFERENCE."
REFERENCE
"Document [25] from References, Figure 8-23."
::= { docsIfCmStatusEntry 17 }
--
-- The Cable Modem Service Table
--
docsIfCmServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the attributes of each upstream service queue
on a CM."
::= { docsIfCmObjects 3 }
docsIfCmServiceEntry OBJECT-TYPE
SYNTAX DocsIfCmServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the attributes of an upstream bandwidth service
queue.
An entry in this table exists for each Service ID.
The primary index is an ifIndex with an ifType of
docsCableMaclayer(127)."
INDEX { ifIndex, docsIfCmServiceId }
::= { docsIfCmServiceTable 1 }
DocsIfCmServiceEntry ::= SEQUENCE {
docsIfCmServiceId Integer32,
docsIfCmServiceQosProfile Integer32,
docsIfCmServiceTxSlotsImmed Counter32,
docsIfCmServiceTxSlotsDed Counter32,
docsIfCmServiceTxRetries Counter32,
docsIfCmServiceTxExceededs Counter32,
docsIfCmServiceRqRetries Counter32,
docsIfCmServiceRqExceededs Counter32,
docsIfCmServiceExtTxSlotsImmed Counter64,
docsIfCmServiceExtTxSlotsDed Counter64
}
docsIfCmServiceId OBJECT-TYPE
SYNTAX Integer32 (1..16383)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identifies a service queue for upstream bandwidth. The
attributes of this service queue are shared between the
CM and the CMTS. The CMTS allocates upstream bandwidth
to this service queue based on requests from the CM and
on the class of service associated with this queue."
::= { docsIfCmServiceEntry 1 }
docsIfCmServiceQosProfile OBJECT-TYPE
SYNTAX Integer32 (0..16383)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index in docsIfQosProfileTable describing the quality
of service attributes associated with this particular
service. If no associated entry in docsIfQosProfileTable
exists, this object returns a value of zero."
::= { docsIfCmServiceEntry 2 }
docsIfCmServiceTxSlotsImmed OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of upstream mini-slots which have been used to
transmit data PDUs in immediate (contention) mode. This
includes only those PDUs that are presumed to have
arrived at the headend (i.e., those which were explicitly
acknowledged.) It does not include retransmission attempts
or mini-slots used by Requests."
REFERENCE
"Document [25] from References, Section 9.4."
::= { docsIfCmServiceEntry 3 }
docsIfCmServiceTxSlotsDed OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of upstream mini-slots which have been used to
transmit data PDUs in dedicated mode (i.e., as a result
of a unicast Data Grant)."
REFERENCE
"Document [25] from References, Section 9.4."
::= { docsIfCmServiceEntry 4 }
docsIfCmServiceTxRetries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of attempts to transmit data PDUs containing
requests for acknowledgment that did not result in
acknowledgment."
REFERENCE
"Document [25] from References, Section 9.4."
::= { docsIfCmServiceEntry 5 }
docsIfCmServiceTxExceededs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data PDUs transmission failures due to
excessive retries without acknowledgment."
REFERENCE
"Document [25] from References, Section 9.4."
::= { docsIfCmServiceEntry 6 }
docsIfCmServiceRqRetries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of attempts to transmit bandwidth requests
which did not result in acknowledgment."
REFERENCE
"Document [25] from References, Section 9.4."
::= { docsIfCmServiceEntry 7 }
docsIfCmServiceRqExceededs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of requests for bandwidth which failed due to
excessive retries without acknowledgment."
REFERENCE
"Document [25] from References, Section 9.4."
::= { docsIfCmServiceEntry 8 }
docsIfCmServiceExtTxSlotsImmed OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of upstream mini-slots which have been used to
transmit data PDUs in immediate (contention) mode. This
includes only those PDUs that are presumed to have
arrived at the headend (i.e., those which were explicitly
acknowledged.) It does not include retransmission attempts
or mini-slots used by Requests."
REFERENCE
"Document [25] from References, Section 9.4."
::= { docsIfCmServiceEntry 9 }
docsIfCmServiceExtTxSlotsDed OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of upstream mini-slots which have been used to
transmit data PDUs in dedicated mode (i.e., as a result
of a unicast Data Grant)."
REFERENCE
"Document [25] from References, Section 9.4."
::= { docsIfCmServiceEntry 10 }
--
-- CMTS GROUP
--
--
-- The CMTS MAC Table
--
docsIfCmtsMacTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmtsMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the attributes of each CMTS MAC interface,
extending the information available from ifEntry.
Mandatory for all CMTS devices."
::= { docsIfCmtsObjects 1 }
docsIfCmtsMacEntry OBJECT-TYPE
SYNTAX DocsIfCmtsMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing objects describing attributes of each
MAC entry, extending the information in ifEntry.
An entry in this table exists for each ifEntry with an
ifType of docsCableMaclayer(127)."
INDEX { ifIndex }
::= { docsIfCmtsMacTable 1 }
DocsIfCmtsMacEntry ::= SEQUENCE {
docsIfCmtsCapabilities BITS,
docsIfCmtsSyncInterval Integer32,
docsIfCmtsUcdInterval Integer32,
docsIfCmtsMaxServiceIds Integer32,
docsIfCmtsInsertionInterval TimeTicks, -- Obsolete
docsIfCmtsInvitedRangingAttempts Integer32,
docsIfCmtsInsertInterval TimeInterval
}
docsIfCmtsCapabilities OBJECT-TYPE
SYNTAX BITS {
atmCells(0),
concatenation(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the capabilities of the CMTS MAC
implementation at this interface. Note that packet
transmission is always supported. Therefore, there
is no specific bit required to explicitly indicate
this capability.
Note that BITS objects are encoded most significant bit
first. For example, if bit 1 is set, the value of this
object is the octet string '40'H."
::= { docsIfCmtsMacEntry 1 }
docsIfCmtsSyncInterval OBJECT-TYPE
SYNTAX Integer32 (1..200)
UNITS "Milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval between CMTS transmission of successive SYNC
messages at this interface."
REFERENCE
"Document [25] from References, Section 9.3."
::= { docsIfCmtsMacEntry 2 }
docsIfCmtsUcdInterval OBJECT-TYPE
SYNTAX Integer32 (1..2000)
UNITS "Milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval between CMTS transmission of successive
Upstream Channel Descriptor messages for each upstream
channel at this interface."
REFERENCE
"Document [25] from References, Section 9.3"
::= { docsIfCmtsMacEntry 3 }
docsIfCmtsMaxServiceIds OBJECT-TYPE
SYNTAX Integer32 (1..16383)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of service IDs that may be
simultaneously active."
::= { docsIfCmtsMacEntry 4 }
-- This object has been obsoleted and replaced by
-- docsIfCmtsInsertInterval to fix a SYNTAX typing problem. New
-- implementations of this MIB should use that object instead.
docsIfCmtsInsertionInterval OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"The amount of time to elapse between each broadcast
station maintenance grant. Broadcast station maintenance
grants are used to allow new cable modems to join the
network. Zero indicates that a vendor-specific algorithm
is used instead of a fixed time. Maximum amount of time
permitted by the specification is 2 seconds."
REFERENCE
"Document [25] from References, Annex B."
::= { docsIfCmtsMacEntry 5 }
docsIfCmtsInvitedRangingAttempts OBJECT-TYPE
SYNTAX Integer32 (0..1024)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of attempts to make on invitations
for ranging requests. A value of zero means the system
should attempt to range forever."
REFERENCE
"Document [25] from References, Section 9.3.3 and Annex B."
::= { docsIfCmtsMacEntry 6 }
docsIfCmtsInsertInterval OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The amount of time to elapse between each broadcast
station maintenance grant. Broadcast station maintenance
grants are used to allow new cable modems to join the
network. Zero indicates that a vendor-specific algorithm
is used instead of a fixed time. Maximum amount of time
permitted by the specification is 2 seconds."
REFERENCE
"Document [25] from References, Annex B."
::= { docsIfCmtsMacEntry 7 }
--
--
-- CMTS status table.
--
docsIfCmtsStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmtsStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For the MAC layer, this group maintains a number of
status objects and counters."
::= { docsIfCmtsObjects 2 }
docsIfCmtsStatusEntry OBJECT-TYPE
SYNTAX DocsIfCmtsStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status entry for a single MAC layer.
An entry in this table exists for each ifEntry with an
ifType of docsCableMaclayer(127)."
INDEX { ifIndex }
::= { docsIfCmtsStatusTable 1 }
DocsIfCmtsStatusEntry ::= SEQUENCE {
docsIfCmtsStatusInvalidRangeReqs Counter32,
docsIfCmtsStatusRangingAborteds Counter32,
docsIfCmtsStatusInvalidRegReqs Counter32,
docsIfCmtsStatusFailedRegReqs Counter32,
docsIfCmtsStatusInvalidDataReqs Counter32,
docsIfCmtsStatusT5Timeouts Counter32
}
docsIfCmtsStatusInvalidRangeReqs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object counts invalid RNG-REQ messages received on
this interface."
REFERENCE
"Document [25] from References, Section 8.3.5."
::= { docsIfCmtsStatusEntry 1 }
docsIfCmtsStatusRangingAborteds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object counts ranging attempts that were explicitly
aborted by the CMTS."
REFERENCE
"Document [25] from References, Section 8.3.6."
::= { docsIfCmtsStatusEntry 2 }
docsIfCmtsStatusInvalidRegReqs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object counts invalid REG-REQ messages received on
this interface. That is, syntax, out of range parameters,
or erroneous requests."
REFERENCE
"Document [25] from References, Section 8.3.7."
::= { docsIfCmtsStatusEntry 3 }
docsIfCmtsStatusFailedRegReqs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object counts failed registration attempts. Included are
docsIfCmtsStatusInvalidRegReqs, authentication and class of
service failures."
REFERENCE
"Document [25] from References, Section 8.3.7."
::= { docsIfCmtsStatusEntry 4 }
docsIfCmtsStatusInvalidDataReqs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object counts invalid data request messages
received on this interface."
::= { docsIfCmtsStatusEntry 5 }
docsIfCmtsStatusT5Timeouts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object counts the number of times counter T5
expired on this interface."
REFERENCE
"Document [25] from References, Figure 9-2."
::= { docsIfCmtsStatusEntry 6 }
--
-- CM status table (within CMTS).
-- This table is implemented only at the CMTS.
-- It contains per CM status information available in the CMTS.
--
docsIfCmtsCmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmtsCmStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of objects in the CMTS, maintained for each
Cable Modem connected to this CMTS."
::= { docsIfCmtsObjects 3 }
docsIfCmtsCmStatusEntry OBJECT-TYPE
SYNTAX DocsIfCmtsCmStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status information for a single Cable Modem.
An entry in this table exists for each Cable Modem
that is connected to the CMTS implementing this table."
INDEX { docsIfCmtsCmStatusIndex }
::= { docsIfCmtsCmStatusTable 1 }
DocsIfCmtsCmStatusEntry ::= SEQUENCE {
docsIfCmtsCmStatusIndex Integer32,
docsIfCmtsCmStatusMacAddress MacAddress,
docsIfCmtsCmStatusIpAddress IpAddress, -- Deprecated
docsIfCmtsCmStatusDownChannelIfIndex InterfaceIndexOrZero,
docsIfCmtsCmStatusUpChannelIfIndex InterfaceIndexOrZero,
docsIfCmtsCmStatusRxPower TenthdBmV,
docsIfCmtsCmStatusTimingOffset Unsigned32,
docsIfCmtsCmStatusEqualizationData OCTET STRING,
docsIfCmtsCmStatusValue INTEGER,
docsIfCmtsCmStatusUnerroreds Counter32,
docsIfCmtsCmStatusCorrecteds Counter32,
docsIfCmtsCmStatusUncorrectables Counter32,
docsIfCmtsCmStatusSignalNoise TenthdB,
docsIfCmtsCmStatusMicroreflections Integer32,
docsIfCmtsCmStatusExtUnerroreds Counter64,
docsIfCmtsCmStatusExtCorrecteds Counter64,
docsIfCmtsCmStatusExtUncorrectables Counter64,
docsIfCmtsCmStatusDocsisRegMode DocsisQosVersion,
docsIfCmtsCmStatusModulationType DocsisUpstreamTypeStatus,
docsIfCmtsCmStatusInetAddressType InetAddressType,
docsIfCmtsCmStatusInetAddress InetAddress,
docsIfCmtsCmStatusValueLastUpdate TimeStamp
}
docsIfCmtsCmStatusIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index value to uniquely identify an entry in this table.
For an individual Cable Modem, this index value should
not change during CMTS uptime."
::= { docsIfCmtsCmStatusEntry 1 }
docsIfCmtsCmStatusMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of this Cable Modem. If the Cable Modem has
multiple MAC addresses, this is the MAC address associated
with the Cable interface."
REFERENCE
"Document [25] from References, Section 8.2.2."
::= { docsIfCmtsCmStatusEntry 2 }
docsIfCmtsCmStatusIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"IP address of this Cable Modem. If the Cable Modem has no
IP address assigned, or the IP address is unknown, this
object returns a value of 0.0.0.0. If the Cable Modem has
multiple IP addresses, this object returns the IP address
associated with the Cable interface.
This object has been deprecated and replaced by
docsIfCmtsCmStatusInetAddressType and
docsIfCmtsCmStatusInetAddress, to enable IPv6 addressing
in the future."
::= { docsIfCmtsCmStatusEntry 3 }
docsIfCmtsCmStatusDownChannelIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IfIndex of the downstream channel this CM is connected
to. If the downstream channel is unknown, this object
returns a value of zero."
::= { docsIfCmtsCmStatusEntry 4 }
docsIfCmtsCmStatusUpChannelIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IfIndex of the upstream channel this CM is connected
to. If the upstream channel is unknown, this object
returns a value of zero."
::= { docsIfCmtsCmStatusEntry 5 }
docsIfCmtsCmStatusRxPower OBJECT-TYPE
SYNTAX TenthdBmV
UNITS "dBmV"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The receive power as perceived for upstream data from
this Cable Modem.
If the receive power is unknown, this object returns
a value of zero."
REFERENCE
"Document [25] from References, Table 6-11."
::= { docsIfCmtsCmStatusEntry 6 }
docsIfCmtsCmStatusTimingOffset OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A measure of the current round trip time for this CM.
Used for timing of CM upstream transmissions to ensure
synchronized arrivals at the CMTS. Units are in terms
of 6.25 microseconds/(64*256). Returns zero if the value
is unknown."
REFERENCE
"Document [25] from References, Section 6.2.18."
::= { docsIfCmtsCmStatusEntry 7 }
docsIfCmtsCmStatusEqualizationData OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Equalization data for this CM. Returns an empty string
if the value is unknown or if there is no equalization
data available or defined."
REFERENCE
"Document [25] from References, Figure 8-23."
::= { docsIfCmtsCmStatusEntry 8 }
docsIfCmtsCmStatusValue OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ranging(2),
rangingAborted(3),
rangingComplete(4),
ipComplete(5),
registrationComplete(6),
accessDenied(7),
operational(8), -- deprecated, ECN OSS2-N-03069
registeredBPIInitializing(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Cable Modem connectivity state, as specified
in the RF Interface Specification. Returned status
information is the CM status as assumed by the CMTS,
and indicates the following events:
other(1)
Any state other than below.
ranging(2)
The CMTS has received an Initial Ranging Request
message from the CM, and the ranging process is not
yet complete.
rangingAborted(3)
The CMTS has sent a Ranging Abort message to the CM.
rangingComplete(4)
The CMTS has sent a Ranging Complete message to the CM.
ipComplete(5)
The CMTS has received a DHCP reply message and forwarded
it to the CM.
registrationComplete(6)
The CMTS has sent a Registration Response message to
the CM.
accessDenied(7)
The CMTS has sent a Registration Aborted message
to the CM.
operational(8)
If Baseline Privacy is enabled for the CM, the CMTS has
completed Baseline Privacy initialization. If Baseline
Privacy is not enabled, equivalent to registrationComplete.
registeredBPIInitializing(9)
Baseline Privacy is enabled, CMTS is in the process of
completing the Baseline Privacy initialization. This state
can last for a significant time in the case of failures
during the process. After Baseline Privacy initialization
is complete, the CMTS will repost back the value
registrationComplete(6).
The CMTS only needs to report states it is able to detect."
REFERENCE
"Document [25] from References, Section 11.2."
::= { docsIfCmtsCmStatusEntry 9 }
docsIfCmtsCmStatusUnerroreds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codewords received without error from this Cable Modem."
REFERENCE
"Document [25] from References, Section 6.2.5."
::= { docsIfCmtsCmStatusEntry 10 }
docsIfCmtsCmStatusCorrecteds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codewords received with correctable errors from this
Cable Modem."
REFERENCE
"Document [25] from References, Section 6.2.5."
::= { docsIfCmtsCmStatusEntry 11 }
docsIfCmtsCmStatusUncorrectables OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codewords received with uncorrectable errors from this
Cable Modem."
REFERENCE
"Document [25] from References, Section 6.2.5."
::= { docsIfCmtsCmStatusEntry 12 }
docsIfCmtsCmStatusSignalNoise OBJECT-TYPE
SYNTAX TenthdB
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal/Noise ratio as perceived for upstream data from
this Cable Modem.
If the Signal/Noise is unknown, this object returns
a value of zero."
REFERENCE
"Document [25] from References, Tables 4-1 and 4-2."
::= { docsIfCmtsCmStatusEntry 13 }
docsIfCmtsCmStatusMicroreflections OBJECT-TYPE
SYNTAX Integer32 (0..255)
UNITS "dBc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total microreflections including in-channel response
as perceived on this interface, measured in dBc below
the signal level.
This object is not assumed to return an absolutely
accurate value, but should give a rough indication
of microreflections received on this interface.
It is up to the implementer to provide information
as accurate as possible."
REFERENCE
"Document [25] from References, Tables 4-1 and 4-2"
::= { docsIfCmtsCmStatusEntry 14 }
docsIfCmtsCmStatusExtUnerroreds OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codewords received without error from this Cable Modem."
REFERENCE
"Document [25] from References, Section 6.2.5."
::= { docsIfCmtsCmStatusEntry 15 }
docsIfCmtsCmStatusExtCorrecteds OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codewords received with correctable errors from this
Cable Modem."
REFERENCE
"Document [25] from References, Section 6.2.5."
::= { docsIfCmtsCmStatusEntry 16 }
docsIfCmtsCmStatusExtUncorrectables OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codewords received with uncorrectable errors from this
Cable Modem."
REFERENCE
"Document [25] from References, Section 6.2.5."
::= { docsIfCmtsCmStatusEntry 17 }
docsIfCmtsCmStatusDocsisRegMode OBJECT-TYPE
SYNTAX DocsisQosVersion
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Indication whether the CM has registered using 1.0 Class of
Service or 1.1 Quality of Service.
This object mirrors docsIfCmtsCmStatusDocsisMode from the
docsIfExt mib."
REFERENCE
"Document [25] from References, Annex G."
::= { docsIfCmtsCmStatusEntry 18 }
docsIfCmtsCmStatusModulationType OBJECT-TYPE
SYNTAX DocsisUpstreamTypeStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates modulation type currently used by the CM. Since
this object specifically identifies PHY mode, the shared
type is not permitted. If the upstream channel is unknown,
this object returns a value of zero."
REFERENCE
"Document [25] from References, Table 8-19."
::= { docsIfCmtsCmStatusEntry 19 }
docsIfCmtsCmStatusInetAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of internet address of
docsIfCmtsCmStatusInetAddress. If the cable modem
Internet address is unassigned or unknown, then the
value of this object is unknown(0)."
::= { docsIfCmtsCmStatusEntry 20 }
docsIfCmtsCmStatusInetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Internet address of this Cable Modem. If the Cable Modem
has no Internet address assigned, or the Internet address
is unknown, the value of this object is the empty string.
If the Cable Modem has multiple Internet addresses, this
object returns the Internet address associated with the
Cable (i.e. RF MAC) interface."
::= { docsIfCmtsCmStatusEntry 21 }
docsIfCmtsCmStatusValueLastUpdate OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when docsIfCmtsCmStatusValue was last updated"
::= { docsIfCmtsCmStatusEntry 22 }
--
-- The CMTS Service Table.
--
docsIfCmtsServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmtsServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the attributes of upstream service queues
in a Cable Modem Termination System."
::= { docsIfCmtsObjects 4 }
docsIfCmtsServiceEntry OBJECT-TYPE
SYNTAX DocsIfCmtsServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the attributes of a single upstream bandwidth
service queue.
INTERNET-DRAFT DOCSIS RF Interface MIB November 2001
Entries in this table exist for each ifEntry with an
ifType of docsCableMaclayer(127), and for each service
queue (Service ID) within this MAC layer.
Entries in this table are created with the creation of
individual Service IDs by the MAC layer and removed
when a Service ID is removed."
INDEX { ifIndex, docsIfCmtsServiceId }
::= { docsIfCmtsServiceTable 1 }
DocsIfCmtsServiceEntry ::= SEQUENCE {
docsIfCmtsServiceId Integer32,
docsIfCmtsServiceCmStatusIndex Integer32, -- Deprecated
docsIfCmtsServiceAdminStatus INTEGER,
docsIfCmtsServiceQosProfile Integer32,
docsIfCmtsServiceCreateTime TimeStamp,
docsIfCmtsServiceInOctets Counter32,
docsIfCmtsServiceInPackets Counter32,
docsIfCmtsServiceNewCmStatusIndex Integer32
}
docsIfCmtsServiceId OBJECT-TYPE
SYNTAX Integer32 (1..16383)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identifies a service queue for upstream bandwidth. The
attributes of this service queue are shared between the
Cable Modem and the Cable Modem Termination System.
The CMTS allocates upstream bandwidth to this service
queue based on requests from the CM and on the class of
service associated with this queue."
::= { docsIfCmtsServiceEntry 1 }
docsIfCmtsServiceCmStatusIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Pointer to an entry in docsIfCmtsCmStatusTable identifying
the Cable Modem using this Service Queue. If multiple
Cable Modems are using this Service Queue, the value of
this object is zero.
This object has been deprecated and replaced by
docsIfCmtsServiceNewCmStatusIndex, to fix a mismatch
of the value range with respect to docsIfCmtsCmStatusIndex
(1..2147483647)."
::= { docsIfCmtsServiceEntry 2 }
docsIfCmtsServiceAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
destroyed(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allows a service class for a particular modem to be
suppressed, (re-)enabled, or deleted altogether."
::= { docsIfCmtsServiceEntry 3 }
docsIfCmtsServiceQosProfile OBJECT-TYPE
SYNTAX Integer32 (0..16383)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index in docsIfQosProfileTable describing the quality
of service attributes associated with this particular
service. If no associated docsIfQosProfileTable entry
exists, this object returns a value of zero."
::= { docsIfCmtsServiceEntry 4 }
docsIfCmtsServiceCreateTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this entry was created."
::= { docsIfCmtsServiceEntry 5 }
docsIfCmtsServiceInOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cumulative number of Packet Data octets received
on this Service ID. The count does not include the
size of the Cable MAC header"
::= { docsIfCmtsServiceEntry 6 }
docsIfCmtsServiceInPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cumulative number of Packet Data packets received
on this Service ID."
::= { docsIfCmtsServiceEntry 7 }
docsIfCmtsServiceNewCmStatusIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pointer (via docsIfCmtsCmStatusIndex) to an entry in
docsIfCmtsCmStatusTable identifying the Cable Modem
using this Service Queue. If multiple Cable Modems are
using this Service Queue, the value of this object is
zero."
::= { docsIfCmtsServiceEntry 8 }
--
-- The following table provides upstream channel modulation profiles.
-- Entries in this table can be
-- re-used by one or more upstream channels. An upstream channel will
-- have a modulation profile
-- for each value of docsIfModIntervalUsageCode.
--
docsIfCmtsModulationTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmtsModulationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes a modulation profile associated with one or more
upstream channels."
::= { docsIfCmtsObjects 5 }
docsIfCmtsModulationEntry OBJECT-TYPE
SYNTAX DocsIfCmtsModulationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes a modulation profile for an Interval Usage Code
for one or more upstream channels.
Entries in this table are created by the operator. Initial
default entries may be created at system initialization
time. No individual objects have to be specified in order
to create an entry in this table.
Note that some objects do not have DEFVALs, but do have
calculated defaults and need not be specified during row
creation.
There is no restriction on the changing of values in this
table while their associated rows are active."
INDEX { docsIfCmtsModIndex, docsIfCmtsModIntervalUsageCode}
::= { docsIfCmtsModulationTable 1 }
DocsIfCmtsModulationEntry ::= SEQUENCE {
docsIfCmtsModIndex Integer32,
docsIfCmtsModIntervalUsageCode INTEGER,
docsIfCmtsModControl RowStatus,
docsIfCmtsModType INTEGER,
docsIfCmtsModPreambleLen Integer32,
docsIfCmtsModDifferentialEncoding TruthValue,
docsIfCmtsModFECErrorCorrection Integer32,
docsIfCmtsModFECCodewordLength Integer32,
docsIfCmtsModScramblerSeed Integer32,
docsIfCmtsModMaxBurstSize Integer32,
docsIfCmtsModGuardTimeSize Unsigned32,
docsIfCmtsModLastCodewordShortened TruthValue,
docsIfCmtsModScrambler TruthValue,
docsIfCmtsModByteInterleaverDepth Unsigned32,
docsIfCmtsModByteInterleaverBlockSize Unsigned32,
docsIfCmtsModPreambleType INTEGER,
docsIfCmtsModTcmErrorCorrectionOn TruthValue,
docsIfCmtsModScdmaInterleaverStepSize Unsigned32,
docsIfCmtsModScdmaSpreaderEnable TruthValue,
docsIfCmtsModScdmaSubframeCodes Unsigned32,
docsIfCmtsModChannelType DocsisUpstreamType
}
docsIfCmtsModIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index into the Channel Modulation table representing
a group of Interval Usage Codes, all associated with the
same channel."
::= { docsIfCmtsModulationEntry 1 }
docsIfCmtsModIntervalUsageCode OBJECT-TYPE
SYNTAX INTEGER {
request(1),
requestData(2),
initialRanging(3),
periodicRanging(4),
shortData(5),
longData(6),
advPhyShortData(9),
advPhyLongData(10),
ugs(11)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index into the Channel Modulation table which, when
grouped with other Interval Usage Codes, fully
instantiate all modulation sets for a given upstream
channel."
REFERENCE
"Document [25] from References, Table 8-20."
::= { docsIfCmtsModulationEntry 2 }
docsIfCmtsModControl OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls and reflects the status of rows in this table."
::= { docsIfCmtsModulationEntry 3 }
docsIfCmtsModType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
qpsk(2),
qam16(3),
qam8(4),
qam32(5),
qam64(6),
qam128(7),
qam256(8)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The modulation type used on this channel. Returns
other(1) if the modulation type is neither
qpsk, qam16, qam8, qam32, qam64 or qam128.
Type qam128 is used for SCDMA channels only.
See the reference for the modulation profiles
implied by different modulation types."
REFERENCE
"Document [25] from References, Table 8-19."
DEFVAL { qpsk }
::= { docsIfCmtsModulationEntry 4 }
docsIfCmtsModPreambleLen OBJECT-TYPE
SYNTAX Integer32 (0..1536)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The preamble length for this modulation profile in bits.
Default value is the minimum needed by the implementation
at the CMTS for the given modulation profile."
REFERENCE
"Document [25] from References, Table 8-19."
::= { docsIfCmtsModulationEntry 5 }
docsIfCmtsModDifferentialEncoding OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies whether or not differential encoding is used
on this channel."
REFERENCE
"Document [25] from References, Table 8-19."
DEFVAL { false }
::= { docsIfCmtsModulationEntry 6 }
docsIfCmtsModFECErrorCorrection OBJECT-TYPE
SYNTAX Integer32 (0..16)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of correctable errored bytes (t) used in
forward error correction code. The value of 0 indicates
no correction is employed. The number of check bytes
appended will be twice this value."
REFERENCE
"Document [25] from References, Table 8-19."
DEFVAL { 0 }
::= { docsIfCmtsModulationEntry 7 }
docsIfCmtsModFECCodewordLength OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of data bytes (k) in the forward error
correction codeword.
This object is not used if docsIfCmtsModFECErrorCorrection
is zero."
REFERENCE
"Document [25] from References, Table 8-19."
DEFVAL { 32 }
::= { docsIfCmtsModulationEntry 8 }
docsIfCmtsModScramblerSeed OBJECT-TYPE
SYNTAX Integer32 (0..32767)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The 15 bit seed value for the scrambler polynomial."
REFERENCE
"Document [25] from References, Table 8-19."
DEFVAL { 0 }
::= { docsIfCmtsModulationEntry 9 }
docsIfCmtsModMaxBurstSize OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum number of mini-slots that can be transmitted
during this channel's burst time. Returns zero if the
burst length is bounded by the allocation MAP rather than
this profile.
Default value is 0 except for shortData, where it is 8."
REFERENCE
"Document [25] from References, Table 8-19."
::= { docsIfCmtsModulationEntry 10 }
docsIfCmtsModGuardTimeSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of symbol-times which must follow the end of
this channel's burst. Default value is the minimum time
needed by the implementation for this modulation profile."
REFERENCE
"Document [25] from References, Table 8-19."
::= { docsIfCmtsModulationEntry 11 }
docsIfCmtsModLastCodewordShortened OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates if the last FEC codeword is truncated."
REFERENCE
"Document [25] from References, Table 8-19."
DEFVAL { true }
::= { docsIfCmtsModulationEntry 12 }
docsIfCmtsModScrambler OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates if the scrambler is employed."
REFERENCE
"Document [25] from References, Table 8-19."
DEFVAL { false }
::= { docsIfCmtsModulationEntry 13 }
docsIfCmtsModByteInterleaverDepth OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" ATDMA Byte Interleaver Depth (Ir). This object returns 1 for
non ATDMA profiles. "
REFERENCE
"Document [25] from References, Table 8-19."
DEFVAL { 1 }
::= { docsIfCmtsModulationEntry 14 }
docsIfCmtsModByteInterleaverBlockSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" ATDMA Byte Interleaver Block size (Br). This object returns
zero for non ATDMA profiles "
REFERENCE
"Document [25] from References, Table 8-19."
DEFVAL { 18 }
::= { docsIfCmtsModulationEntry 15 }
docsIfCmtsModPreambleType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
qpsk0(1),
qpsk1(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Preamble type for DOCSIS 2.0 bursts"
REFERENCE
"Document [25] from References, Table 8-19."
DEFVAL { qpsk0 }
::= { docsIfCmtsModulationEntry 16 }
docsIfCmtsModTcmErrorCorrectionOn OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Trellis Code Modulation (TCM) On/Off. This value returns false for
non S-CDMA profiles."
REFERENCE
"Document [25] from References, Table 8-19."
DEFVAL { false }
::= { docsIfCmtsModulationEntry 17 }
docsIfCmtsModScdmaInterleaverStepSize OBJECT-TYPE
SYNTAX Unsigned32 (0 | 1..32)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" S-CDMA Interleaver step size. This value returns zero
for non S-CDMA profiles."
REFERENCE
"Document [25] from References, Table 8-19."
DEFVAL { 1 }
::= { docsIfCmtsModulationEntry 18 }
docsIfCmtsModScdmaSpreaderEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" S-CDMA spreader. This value returns false for non S-CDMA
profiles. Default value for IUC 3 and 4 is OFF, for
all other IUCs it is ON."
REFERENCE
"Document [25] from References, Table 8-19."
::= { docsIfCmtsModulationEntry 19 }
docsIfCmtsModScdmaSubframeCodes OBJECT-TYPE
SYNTAX Unsigned32 (0 | 1..128)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" S-CDMA sub-frame size. This value returns zero
for non S-CDMA profiles."
REFERENCE
"Document [25] from References, Table 8-19."
DEFVAL { 1 }
::= { docsIfCmtsModulationEntry 20 }
docsIfCmtsModChannelType OBJECT-TYPE
SYNTAX DocsisUpstreamType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Describes the modulation channel type for this modulation entry."
REFERENCE
"Document [25] from References, Table 8-19."
DEFVAL { tdma }
::= { docsIfCmtsModulationEntry 21 }
docsIfCmtsQosProfilePermissions OBJECT-TYPE
SYNTAX BITS {
createByManagement(0),
updateByManagement(1),
createByModems(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies permitted methods of creating
entries in docsIfQosProfileTable.
CreateByManagement(0) is set if entries can be created
using SNMP. UpdateByManagement(1) is set if updating
entries using SNMP is permitted. CreateByModems(2)
is set if entries can be created based on information
in REG-REQ MAC messages received from Cable Modems.
Information in this object is only applicable if
docsIfQosProfileTable is implemented as read-create.
Otherwise, this object is implemented as read-only
and returns CreateByModems(2).
Either CreateByManagement(0) or CreateByModems(1)
must be set when writing to this object.
Note that BITS objects are encoded most significant bit
first. For example, if bit 2 is set, the value of this
object is the octet string '20'H."
::= { docsIfCmtsObjects 6 }
docsIfCmtsMacToCmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmtsMacToCmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a table to provide a quick access index into the
docsIfCmtsCmStatusTable. There is exactly one row in this
table for each row in the docsIfCmtsCmStatusTable. In
general, the management station should use this table only
to get a pointer into the docsIfCmtsCmStatusTable (which
corresponds to the CM's RF interface MAC address), and
should not iterate (e.g. GetNext through) this table."
::= { docsIfCmtsObjects 7 }
docsIfCmtsMacToCmEntry OBJECT-TYPE
SYNTAX DocsIfCmtsMacToCmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the docsIfCmtsMacToCmTable.
An entry in this table exists for each Cable Modem
that is connected to the CMTS implementing this table."
INDEX { docsIfCmtsCmMac }
::= {docsIfCmtsMacToCmTable 1 }
DocsIfCmtsMacToCmEntry ::= SEQUENCE {
docsIfCmtsCmMac MacAddress,
docsIfCmtsCmPtr Integer32
}
docsIfCmtsCmMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The RF side MAC address for the referenced CM. (E.g. the
interface on the CM that has docsCableMacLayer(127) as
its ifType."
::= { docsIfCmtsMacToCmEntry 1 }
docsIfCmtsCmPtr OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An row index into docsIfCmtsCmStatusTable. When queried
with the correct instance value (e.g. a CM's MAC address),
returns the index in docsIfCmtsCmStatusTable which
represents that CM."
::= { docsIfCmtsMacToCmEntry 2 }
-- The following independent object and associated table provide
-- operators with a mechanism to evaluate the load/utilization of
-- both upstream and downstream physical channels. This information
-- may be used for capacity planning and incident analysis, and may
-- be particularly helpful in provisioning of high value QOS.
--
-- Utilization is expressed as an index representing the calculated
-- percentage utilization of the upstream or downstream channel in
-- the most recent sampling interval (ie. utilization interval).
-- Refer to the DESCRIPTION field of the docsIfCmtsChannelUtUtilization
-- object for definitions and calculation details.
docsIfCmtsChannelUtilizationInterval OBJECT-TYPE
SYNTAX Integer32 (0..86400)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time interval in seconds over which the channel utilization
index is calculated. All upstream/downstream channels use the
same docsIfCmtsChannelUtilizationInterval.
Setting a value of zero disables utilization reporting.
A channel utilization index is calculated over a fixed window
applying to the most recent docsIfCmtsChannelUtilizationInterval.
It would therefore be prudent to use a relatively short
docsIfCmtsChannelUtilizationInterval."
::= { docsIfCmtsObjects 8 }
docsIfCmtsChannelUtilizationTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmtsChannelUtilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Reports utilization statistics for attached upstream and
downstream physical channels."
::= { docsIfCmtsObjects 9 }
docsIfCmtsChannelUtilizationEntry OBJECT-TYPE
SYNTAX DocsIfCmtsChannelUtilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Utilization statistics for a single upstream or downstream
physical channel. An entry exists in this table for each
ifEntry with an ifType equal to docsCableDownstreamInterface
(128) or docsCableUpstreamInterface (129)."
INDEX { ifIndex, docsIfCmtsChannelUtIfType, docsIfCmtsChannelUtId }
::= { docsIfCmtsChannelUtilizationTable 1 }
DocsIfCmtsChannelUtilizationEntry ::= SEQUENCE {
docsIfCmtsChannelUtIfType IANAifType,
docsIfCmtsChannelUtId Integer32,
docsIfCmtsChannelUtUtilization Integer32
}
docsIfCmtsChannelUtIfType OBJECT-TYPE
SYNTAX IANAifType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The secondary index into this table. Indicates the IANA
interface type associated with this physical channel. Only
docsCableDownstreamInterface (128) and
docsCableUpstreamInterface (129) are valid."
::= { docsIfCmtsChannelUtilizationEntry 1 }
docsIfCmtsChannelUtId OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The tertiary index into this table. Indicates the CMTS
identifier for this physical channel."
::= { docsIfCmtsChannelUtilizationEntry 2 }
docsIfCmtsChannelUtUtilization OBJECT-TYPE
SYNTAX Integer32 (0..100)
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The calculated and truncated utilization index for this
physical upstream or downstream channel, accurate as of
the most recent docsIfCmtsChannelUtilizationInterval.
Upstream Channel Utilization Index:
The upstream channel utilization index is expressed as a
percentage of minislots utilized on the physical channel, regardless
of burst type. For an Initial Maintenance region, the minislots
for the complete region are considered utilized if the CMTS
received an upstream burst within the region from any CM on the
physical channel. For contention REQ and REQ/DATA regions, the
minislots for a transmission opportunity within the region are
considered utilized if the CMTS received an upstream burst within
the opportunity from any CM on the physical channel. For all other
regions, utilized minislots are those in which the CMTS granted
bandwidth to any unicast SID on the physical channel.
For an upstream interface that has multiple logical upstream
channels enabled, the utilization index is a weighted sum of
utilization indices for the logical channels. The weight for
each utilization index is the percentage of upstream minislots
allocated for the corresponding logical channel.
Example:
If 75% of bandwidth is allocated to the first logical channel
and 25% to the second, and the utilization indices for each are
60 and 40 respectively, the utilization index for the upstream
physical channel is (60 * 0.75) + (40 * 0.25) = 55. This figure
applies to the most recent utilization interval.
Downstream Channel Utilization Index:
The downstream channel utilization index is a percentage expressing
the ratio between bytes used to transmit data versus the total number
of bytes transmitted in the raw bandwidth of the MPEG channel. As
with the upstream utilization index, the calculated value represents
the most recent utilization interval.
Formula:
Downstream utilization index =
(100 * (data bytes / raw bytes)) =
(100 * ((raw bytes - stuffed bytes) / raw bytes))
Definitions:
Data bytes: Number of bytes transmitted as data in the
docsIfCmtsChannelUtilizationInterval.
Stuffed bytes: Number of filler bytes transmitted as non-data in the
DocsIfCmtsChannelUtilizationInterval.
Raw bandwidth: Total number of bytes available for transmitting data,
not including bytes used for headers and other overhead.
Raw bytes: (raw bandwidth * docsIfCmtsChannelUtilizationInterval)."
::= { docsIfCmtsChannelUtilizationEntry 3 }
-- The following table provides operators with input data appropriate for
-- calculating downstream channel utilization. Operators may use the
-- docsIfCmtsChannelUtilizationTable, or perform their own polling of the
-- docsIfCmtsDownChannelCounterTable objects to characterize their downstream
-- channel usage.
-- The 32 bit counter objects are included to provide backward compatibility
-- with SNMPv1 managers, which cannot access 64 bit counter objects.
docsIfCmtsDownChannelCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmtsDownChannelCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is implemented at the CMTS to collect downstream
channel statistics for utilization calculations."
::= { docsIfCmtsObjects 10 }
docsIfCmtsDownChannelCounterEntry OBJECT-TYPE
SYNTAX DocsIfCmtsDownChannelCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry provides a list of traffic counters for a single
downstream channel.
An entry in this table exists for each ifEntry with an
ifType of docsCableDownstream(128)."
INDEX { ifIndex }
::= { docsIfCmtsDownChannelCounterTable 1 }
DocsIfCmtsDownChannelCounterEntry ::= SEQUENCE {
docsIfCmtsDownChnlCtrId Integer32,
docsIfCmtsDownChnlCtrTotalBytes Counter32,
docsIfCmtsDownChnlCtrUsedBytes Counter32,
docsIfCmtsDownChnlCtrExtTotalBytes Counter64,
docsIfCmtsDownChnlCtrExtUsedBytes Counter64
}
docsIfCmtsDownChnlCtrId OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Cable Modem Termination System (CMTS) identification
of the downstream channel within this particular MAC
interface. If the interface is down, the object returns
the most current value. If the downstream channel ID is
unknown, this object returns a value of 0."
::= { docsIfCmtsDownChannelCounterEntry 1 }
docsIfCmtsDownChnlCtrTotalBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"At the CMTS, the total number of bytes in the Payload portion
of MPEG Packets (ie. not including MPEG header or pointer_field)
transported by this downstream channel since CMTS initialization.
This is the 32 bit version of docsIfCmtsDownChnlCtrExtTotalBytes,
included to provide back compatibility with SNMPv1 managers."
::= { docsIfCmtsDownChannelCounterEntry 2 }
docsIfCmtsDownChnlCtrUsedBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"At the CMTS, the total number of DOCSIS data bytes transported
by this downstream channel since CMTS initialization. The number
of data bytes is defined as the total number of bytes transported
in DOCSIS payloads minus the number of stuff bytes transported in
DOCSIS payloads.
This is the 32 bit version of docsIfCmtsDownChnlCtrExtUsedBytes,
included to provide back compatibility with SNMPv1 managers."
::= { docsIfCmtsDownChannelCounterEntry 3 }
docsIfCmtsDownChnlCtrExtTotalBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"At the CMTS, the total number of bytes in the Payload portion
of MPEG Packets (ie. not including MPEG header or pointer_field)
transported by this downstream channel since CMTS initialization.
This is the 64 bit version of docsIfCmtsDownChnlCtrTotalBytes, and
will not be accessible to SNMPv1 managers."
::= { docsIfCmtsDownChannelCounterEntry 4 }
docsIfCmtsDownChnlCtrExtUsedBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"At the CMTS, the total number of DOCSIS data bytes transported
by this downstream channel since CMTS initialization. The number
of data bytes is defined as the total number of bytes transported
in DOCSIS payloads minus the number of stuff bytes transported in
DOCSIS payloads.
This is the 64 bit version of docsIfCmtsDownChnlCtrUsedBytes, and
will not be accessible to SNMPv1 managers."
::= { docsIfCmtsDownChannelCounterEntry 5 }
-- The following table provides operators with input data appropriate for
-- calculating upstream channel utilization, and for determining the traffic
-- characteristics of upstream channels.
-- Operators may use the docsIfCmtsChannelUtilizationTable, or perform their own
-- polling of the docsIfCmtsUpChannelCounterTable objects for utilization
-- determination.
-- The first four 32 and 64 objects in this table are mandatory. Vendors may
-- choose to implement the remaining optional objects to provide operators with
-- finer characterization of upstream channel traffic patterns.
-- The 32 bit counter objects are included to provide backward compatibility
-- with SNMPv1 managers, which cannot access 64 bit counter objects.
docsIfCmtsUpChannelCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmtsUpChannelCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is implemented at the CMTS to provide upstream
channel statistics appropriate for channel utilization
calculations."
::= { docsIfCmtsObjects 11 }
docsIfCmtsUpChannelCounterEntry OBJECT-TYPE
SYNTAX DocsIfCmtsUpChannelCounterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of traffic statistics for a single upstream channel.
For Docsis 2.0 CMTSs, an entry in this table exists for
each ifEntry with an ifType of docsCableUpstreamChannel (205).
For Docsis 1.x CMTSs, an entry in this table exists for each
ifEntry with an ifType of docsCableUpstreamInterface (129)."
INDEX { ifIndex }
::= { docsIfCmtsUpChannelCounterTable 1 }
DocsIfCmtsUpChannelCounterEntry ::= SEQUENCE {
docsIfCmtsUpChnlCtrId Integer32,
docsIfCmtsUpChnlCtrTotalMslots Counter32,
docsIfCmtsUpChnlCtrUcastGrantedMslots Counter32,
docsIfCmtsUpChnlCtrTotalCntnMslots Counter32,
docsIfCmtsUpChnlCtrUsedCntnMslots Counter32,
docsIfCmtsUpChnlCtrExtTotalMslots Counter64,
docsIfCmtsUpChnlCtrExtUcastGrantedMslots Counter64,
docsIfCmtsUpChnlCtrExtTotalCntnMslots Counter64,
docsIfCmtsUpChnlCtrExtUsedCntnMslots Counter64,
docsIfCmtsUpChnlCtrCollCntnMslots Counter32,
docsIfCmtsUpChnlCtrTotalCntnReqMslots Counter32,
docsIfCmtsUpChnlCtrUsedCntnReqMslots Counter32,
docsIfCmtsUpChnlCtrCollCntnReqMslots Counter32,
docsIfCmtsUpChnlCtrTotalCntnReqDataMslots Counter32,
docsIfCmtsUpChnlCtrUsedCntnReqDataMslots Counter32,
docsIfCmtsUpChnlCtrCollCntnReqDataMslots Counter32,
docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots Counter32,
docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots Counter32,
docsIfCmtsUpChnlCtrCollCntnInitMaintMslots Counter32,
docsIfCmtsUpChnlCtrExtCollCntnMslots Counter64,
docsIfCmtsUpChnlCtrExtTotalCntnReqMslots Counter64,
docsIfCmtsUpChnlCtrExtUsedCntnReqMslots Counter64,
docsIfCmtsUpChnlCtrExtCollCntnReqMslots Counter64,
docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots Counter64,
docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots Counter64,
docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots Counter64,
docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots Counter64,
docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots Counter64,
docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots Counter64
}
docsIfCmtsUpChnlCtrId OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CMTS identification of the upstream channel."
::= { docsIfCmtsUpChannelCounterEntry 1 }
docsIfCmtsUpChnlCtrTotalMslots OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of all minislots
defined for this upstream logical channel. This count includes
all IUCs and SIDs, even those allocated to the NULL SID for
a 2.0 logical channel which is inactive.
This is the 32 bit version of docsIfCmtsUpChnlCtrExtTotalMslots,
and is included for back compatibility with SNMPv1 managers.
Support for this object is mandatory."
::= { docsIfCmtsUpChannelCounterEntry 2 }
docsIfCmtsUpChnlCtrUcastGrantedMslots OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of unicast granted
minislots on the upstream logical channel, regardless of burst
type. Unicast granted minislots are those in which the CMTS
assigned bandwidth to any unicast SID on the logical channel.
This is the 32 bit version of docsIfCmtsUpChnlCtrExtUcastGrantedMslots,
and is included for back compatibility with SNMPv1 managers.
Support for this object is mandatory."
::= { docsIfCmtsUpChannelCounterEntry 3 }
docsIfCmtsUpChnlCtrTotalCntnMslots OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention minislots
defined for this upstream logical channel. This count includes
all minislots assigned to a broadcast or multicast SID on the
logical channel.
This is the 32 bit version of docsIfCmtsUpChnlCtrExtTotalCntnMslots,
and is included for back compatibility with SNMPv1 managers.
Support for this object is mandatory."
::= { docsIfCmtsUpChannelCounterEntry 4 }
docsIfCmtsUpChnlCtrUsedCntnMslots OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention minislots
utilized on the upstream logical channel. For contention regions,
utilized minislots are those in which the CMTS correctly received
an upstream burst from any CM on the upstream logical channel.
This is the 32 bit version of docsIfCmtsUpChnlCtrExtUsedCntnMslots,
and is included for back compatibility with SNMPv1 managers.
Support for this object is mandatory."
::= { docsIfCmtsUpChannelCounterEntry 5 }
docsIfCmtsUpChnlCtrExtTotalMslots OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of all minislots
defined for this upstream logical channel. This count includes
all IUCs and SIDs, even those allocated to the NULL SID for
a 2.0 logical channel which is inactive.
This is the 64 bit version of docsIfCmtsUpChnlCtrTotalMslots,
and will not be accessible to SNMPv1 managers.
Support for this object is mandatory."
::= { docsIfCmtsUpChannelCounterEntry 6 }
docsIfCmtsUpChnlCtrExtUcastGrantedMslots OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of unicast granted
minislots on the upstream logical channel, regardless of burst
type. Unicast granted minislots are those in which the CMTS
assigned bandwidth to any unicast SID on the logical channel.
This is the 64 bit version of docsIfCmtsUpChnlCtrUcastGrantedMslots,
and will not be accessible to SNMPv1 managers.
Support for this object is mandatory."
::= { docsIfCmtsUpChannelCounterEntry 7 }
docsIfCmtsUpChnlCtrExtTotalCntnMslots OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention minislots
defined for this upstream logical channel. This count includes
all minislots assigned to a broadcast or multicast SID on the
logical channel.
This is the 64 bit version of docsIfCmtsUpChnlCtrTotalCntnMslots,
and will not be accessible to SNMPv1 managers.
Support for this object is mandatory."
::= { docsIfCmtsUpChannelCounterEntry 8 }
docsIfCmtsUpChnlCtrExtUsedCntnMslots OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention minislots
utilized on the upstream logical channel. For contention regions,
utilized minislots are those in which the CMTS correctly received
an upstream burst from any CM on the upstream logical channel.
This is the 64 bit version of docsIfCmtsUpChnlCtrUsedCntnMslots,
and will not be accessible to SNMPv1 managers.
Support for this object is mandatory."
::= { docsIfCmtsUpChannelCounterEntry 9 }
docsIfCmtsUpChnlCtrCollCntnMslots OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention minislots
subjected to collisions on the upstream logical channel. For
contention regions, these are the minislots applicable to bursts
that the CMTS detected, but could not correctly receive.
This is the 32 bit version of docsIfCmtsUpChnlCtrExtCollCntnMslots,
and is included for back compatibility with SNMPv1 managers.
Support for this object is optional. If the object is not supported,
a value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 10 }
docsIfCmtsUpChnlCtrTotalCntnReqMslots OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention request
minislots defined for this upstream logical channel. This count
includes all minislots for IUC1 assigned to a broadcast or multicast
SID on the logical channel.
This is the 32 bit version of docsIfCmtsUpChnlCtrExtTotalCntnReqMslots,
and is included for back compatibility with SNMPv1 managers.
Support for this object is optional. If the object is not supported,
A value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 11 }
docsIfCmtsUpChnlCtrUsedCntnReqMslots OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention request
minislots utilized on this upstream logical channel. This count
includes all contention minislots for IUC1 applicable to bursts
that the CMTS correctly received.
This is the 32 bit version of docsIfCmtsUpChnlCtrExtUsedCntnReqMslots,
and is included for back compatibility with SNMPv1 managers.
Support for this object is optional. If the object is not supported,
A value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 12 }
docsIfCmtsUpChnlCtrCollCntnReqMslots OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention request
minislots subjected to collisions on this upstream logical channel.
This includes all contention minislots for IUC1 applicable to bursts
that the CMTS detected, but could not correctly receive.
This is the 32 bit version of docsIfCmtsUpChnlCtrExtCollCntnReqMslots,
and is included for back compatibility with SNMPv1 managers.
Support for this object is optional. If the object is not supported,
A value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 13 }
docsIfCmtsUpChnlCtrTotalCntnReqDataMslots OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention request
data minislots defined for this upstream logical channel. This count
includes all minislots for IUC2 assigned to a broadcast or multicast
SID on the logical channel.
This is the 32 bit version of
docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots,
and is included for back compatibility with SNMPv1 managers.
Support for this object is optional. If the object is not supported,
A value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 14 }
docsIfCmtsUpChnlCtrUsedCntnReqDataMslots OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention request
data minislots utilized on this upstream logical channel. This
includes all contention minislots for IUC2 applicable to bursts
that the CMTS correctly received.
This is the 32 bit version of
docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots,
and is included for back compatibility with SNMPv1 managers.
Support for this object is optional. If the object is not supported,
A value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 15 }
docsIfCmtsUpChnlCtrCollCntnReqDataMslots OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention request
data minislots subjected to collisions on this upstream logical
channel. This includes all contention minislots for IUC2 applicable
to bursts that the CMTS detected, but could not correctly receive.
This is the 32 bit version of
docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots,
and is included for back compatibility with SNMPv1 managers.
Support for this object is optional. If the object is not supported,
A value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 16 }
docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention initial
maintenance minislots defined for this upstream logical channel.
This includes all minislots for IUC3 assigned to a broadcast or
multicast SID on the logical channel.
This is the 32 bit version of
docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots,
and is included for back compatibility with SNMPv1 managers.
Support for this object is optional. If the object is not supported,
A value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 17 }
docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention initial
maintenance minislots utilized on this upstream logical channel.
This includes all contention minislots for IUC3 applicable to bursts
that the CMTS correctly received.
This is the 32 bit version of
docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots,
and is included for back compatibility with SNMPv1 managers.
Support for this object is optional. If the object is not supported,
A value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 18 }
docsIfCmtsUpChnlCtrCollCntnInitMaintMslots OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention initial
maintenance minislots subjected to collisions on this upstream
logical channel. This includes all contention minislots for IUC3
applicable to bursts that the CMTS detected, but could not correctly
receive.
This is the 32 bit version of
docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots,
and is included for back compatibility with SNMPv1 managers.
Support for this object is optional. If the object is not supported,
A value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 19 }
docsIfCmtsUpChnlCtrExtCollCntnMslots OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of collision contention
minislots on the upstream logical channel. For contention regions,
these are the minislots applicable to bursts that the CMTS detected,
but could not correctly receive.
This is the 64 bit version of docsIfCmtsUpChnlCtrCollCntnMslots,
and will not be accessible to SNMPv1 managers.
Support for this object is optional. If the object is not supported,
a value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 20 }
docsIfCmtsUpChnlCtrExtTotalCntnReqMslots OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention request
minislots defined for this upstream logical channel. This count
includes all minislots for IUC1 assigned to a broadcast or multicast
SID on the logical channel.
This is the 64 bit version of docsIfCmtsUpChnlCtrTotalCntnReqMslots,
and will not be accessible to SNMPv1 managers.
Support for this object is optional. If the object is not supported,
A value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 21 }
docsIfCmtsUpChnlCtrExtUsedCntnReqMslots OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention request
minislots utilized on this upstream logical channel. This count
includes all contention minislots for IUC1 applicable to bursts
that the CMTS correctly received.
This is the 64 bit version of docsIfCmtsUpChnlCtrUsedCntnReqMslots,
and will not be accessible to SNMPv1 managers.
Support for this object is optional. If the object is not supported,
A value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 22 }
docsIfCmtsUpChnlCtrExtCollCntnReqMslots OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention request
minislots subjected to collisions on this upstream logical channel.
This includes all contention minislots for IUC1 applicable to bursts
that the CMTS detected, but could not correctly receive.
This is the 64 bit version of docsIfCmtsUpChnlCtrCollCntnReqMslots,
and will not be accessible to SNMPv1 managers.
Support for this object is optional. If the object is not supported,
A value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 23 }
docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention request
data minislots defined for this upstream logical channel. This count
includes all minislots for IUC2 assigned to a broadcast or multicast
SID on the logical channel.
This is the 64 bit version of docsIfCmtsUpChnlCtrTotalCntnReqDataMslots,
and will not be accessible to SNMPv1 managers.
Support for this object is optional. If the object is not supported,
A value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 24 }
docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention request
data minislots utilized on this upstream logical channel. This
includes all contention minislots for IUC2 applicable to bursts
that the CMTS correctly received.
This is the 64 bit version of docsIfCmtsUpChnlCtrUsedCntnReqDataMslots,
and will not be accessible to SNMPv1 managers.
Support for this object is optional. If the object is not supported,
A value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 25 }
docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention request
data minislots subjected to collisions on this upstream logical
channel. This includes all contention minislots for IUC2 applicable
to bursts that the CMTS detected, but could not correctly receive.
This is the 64 bit version of docsIfCmtsUpChnlCtrCollCntnReqDataMslots,
and will not be accessible to SNMPv1 managers.
Support for this object is optional. If the object is not supported,
A value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 26 }
docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of initial maintenance
minislots defined for this upstream logical channel. This count
includes all minislots for IUC3 assigned to a broadcast or multicast
SID on the logical channel.
This is the 64 bit version of
docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots,
and will not be accessible to SNMPv1 managers.
Support for this object is optional. If the object is not supported,
A value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 27 }
docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of initial maintenance
minislots utilized on this upstream logical channel. This
includes all contention minislots for IUC3 applicable to bursts
that the CMTS correctly received.
This is the 64 bit version of docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots,
and will not be accessible to SNMPv1 managers.
Support for this object is optional. If the object is not supported,
A value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 28 }
docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current count, from CMTS initialization, of contention initial
maintenance minislots subjected to collisions on this upstream
logical channel. This includes all contention minislots for IUC3
applicable to bursts that the CMTS detected, but could not correctly
receive.
This is the 64 bit version of docsIfCmtsUpChnlCtrCollCntnInitMaintMslots,
and will not be accessible to SNMPv1 managers.
Support for this object is optional. If the object is not supported,
A value of zero is returned."
::= { docsIfCmtsUpChannelCounterEntry 29 }
--
-- notification group is for future extension.
--
docsIfNotification OBJECT IDENTIFIER ::= { docsIfMib 2 }
docsIfConformance OBJECT IDENTIFIER ::= { docsIfMib 3 }
docsIfCompliances OBJECT IDENTIFIER ::= { docsIfConformance 1 }
docsIfGroups OBJECT IDENTIFIER ::= { docsIfConformance 2 }
-- compliance statements
docsIfBasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for devices that implement
MCNS/DOCSIS compliant Radio Frequency Interfaces."
MODULE -- docsIfMib
-- unconditionally mandatory groups
MANDATORY-GROUPS {
docsIfBasicGroup
}
-- conditionally mandatory group
GROUP docsIfCmGroup
DESCRIPTION
"This group is implemented only in Cable Modems, not in
Cable Modem Termination Systems."
-- conditionally mandatory group
GROUP docsIfCmtsGroup
DESCRIPTION
"This group is implemented only in Cable Modem Termination
Systems, not in Cable Modems."
OBJECT docsIfDownChannelFrequency
WRITE-SYNTAX Integer32 (47000000..862000000)
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems,
read-only in Cable Modems.
A range of 54MHz to 860MHz is appropriate for a cable
plant using a North American Sub-Split channel plan.
The spectrum range has been expanded to accommodate
a lower edge of 47MHz and an upper edge of 862MHz
for some European channel plans.
If DOCSIS is extended to cover other types of channel
plans (and frequency allocations) this object will be
modified accordingly."
OBJECT docsIfDownChannelWidth
WRITE-SYNTAX Integer32 (6000000 | 8000000)
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only.
In Cable Modems, this object is always implemented as
read-only. The value of 6 MHz is appropriate for cable
plants running under NTSC (National Television
Standards Committee) standards. The value of 8 MHz is
appropriate for cable plants running under ETSI
standards. For other regional standards, this
object will be modified accordingly."
OBJECT docsIfDownChannelModulation
WRITE-SYNTAX INTEGER {
qam64 (3),
qam256 (4)
}
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems,
read-only in Cable Modems."
OBJECT docsIfDownChannelInterleave
WRITE-SYNTAX INTEGER {
taps8Increment16(3),
taps16Increment8(4),
taps32Increment4(5),
taps64Increment2(6),
taps128Increment1(7),
taps12increment17(8)
}
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems,
read-only in Cable Modems."
OBJECT docsIfDownChannelPower
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems,
read-only in Cable Modems."
OBJECT docsIfUpChannelFrequency
WRITE-SYNTAX Integer32 (5000000..65000000)
MIN-ACCESS read-only
DESCRIPTION
"Read-create in Cable Modem Termination Systems,
read-only in Cable Modems.
A range of 5MHz to 42MHz is appropriate for a cable
plant using a North American Sub-Split channel plan.
The spectrum range has been expanded to accommodate
an upper edge of 65MHz for some European channel plans.
If DOCSIS is extended to cover other types of channel
plans (and frequency allocations) this object will
be modified accordingly."
OBJECT docsIfUpChannelWidth
WRITE-SYNTAX Integer32 (200000..6400000)
MIN-ACCESS read-only
DESCRIPTION
"Read-create in Cable Modem Termination Systems,
read-only in Cable Modems. The above value is appropriate
for cable plants running under NTSC (National Television
Standards Committee) standards. If DOCSIS is extended to
work with other standard (e.g. European standards), this
object will be modified accordingly."
OBJECT docsIfUpChannelModulationProfile
MIN-ACCESS read-only
DESCRIPTION
"Read-create in Cable Modem Termination Systems,
read-only in Cable Modems."
OBJECT docsIfUpChannelSlotSize
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfUpChannelRangingBackoffStart
MIN-ACCESS read-only
DESCRIPTION
"Read-create in Cable Modem Termination Systems,
read-only in Cable Modems."
OBJECT docsIfUpChannelRangingBackoffEnd
MIN-ACCESS read-only
DESCRIPTION
"Read-create in Cable Modem Termination Systems,
read-only in Cable Modems."
OBJECT docsIfUpChannelTxBackoffStart
MIN-ACCESS read-only
DESCRIPTION
"Read-create in Cable Modem Termination Systems,
read-only in Cable Modems."
OBJECT docsIfUpChannelTxBackoffEnd
MIN-ACCESS read-only
DESCRIPTION
"Read-create in Cable Modem Termination Systems,
read-only in Cable Modems."
OBJECT docsIfUpChannelScdmaActiveCodes
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems. The number of active
codes when SCDMA is in use must range from 64 to 128, and must be a non-
Prime value. Providing this range allows for the following features and
capabilities:
1) Power management in S-CDMA spreader-on frames (with a 3 dB spread)
2) Avoidance of code 0
3) Flexible minislot sizes with and without the use of code 0"
OBJECT docsIfUpChannelScdmaCodesPerSlot
MIN-ACCESS read-only
DESCRIPTION
"Read-create in Cable Modem Termination Systems,
read-only in Cable Modems."
OBJECT docsIfUpChannelScdmaFrameSize
MIN-ACCESS read-only
DESCRIPTION
"Read-create in Cable Modem Termination Systems,
read-only in Cable Modems."
OBJECT docsIfUpChannelScdmaHoppingSeed
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems."
OBJECT docsIfUpChannelType
MIN-ACCESS read-only
DESCRIPTION
"Read-create in Cable Modem Termination Systems,
read-only in Cable Modems."
OBJECT docsIfUpChannelCloneFrom
MIN-ACCESS read-only
DESCRIPTION
"Read-create in Cable Modem Termination Systems,
read-only in Cable Modems."
OBJECT docsIfUpChannelUpdate
MIN-ACCESS read-only
DESCRIPTION
"Read-create in Cable Modem Termination Systems,
read-only in Cable Modems."
OBJECT docsIfUpChannelPreEqEnable
MIN-ACCESS read-only
DESCRIPTION
"Read-create in Cable Modem Termination Systems,
read-only in Cable Modems."
OBJECT docsIfQosProfPriority
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfPriority
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfMaxUpBandwidth
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfGuarUpBandwidth
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfMaxDownBandwidth
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfBaselinePrivacy
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfStatus
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfMaxTransmitBurst
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfCmtsServiceAdminStatus
MIN-ACCESS read-only
DESCRIPTION
"It is compliant to implement this object as read-only."
OBJECT docsIfCmtsSyncInterval
MIN-ACCESS read-only
DESCRIPTION
"It is compliant to implement this object as read-only."
OBJECT docsIfCmtsUcdInterval
MIN-ACCESS read-only
DESCRIPTION
"It is compliant to implement this object as read-only."
OBJECT docsIfCmtsInsertInterval
MIN-ACCESS read-only
DESCRIPTION
"It is compliant to implement this object as read-only."
OBJECT docsIfCmtsInvitedRangingAttempts
MIN-ACCESS read-only
DESCRIPTION
"It is compliant to implement this object as read-only."
OBJECT docsIfCmtsQosProfilePermissions
MIN-ACCESS read-only
DESCRIPTION
"It is compliant to implement this object as read-only."
::= { docsIfCompliances 1 }
docsIfBasicGroup OBJECT-GROUP
OBJECTS {
docsIfDownChannelId,
docsIfDownChannelFrequency,
docsIfDownChannelWidth,
docsIfDownChannelModulation,
docsIfDownChannelInterleave,
docsIfDownChannelPower,
docsIfDownChannelAnnex,
docsIfUpChannelId,
docsIfUpChannelFrequency,
docsIfUpChannelWidth,
docsIfUpChannelModulationProfile,
docsIfUpChannelSlotSize,
docsIfUpChannelTxTimingOffset,
docsIfUpChannelRangingBackoffStart,
docsIfUpChannelRangingBackoffEnd,
docsIfUpChannelTxBackoffStart,
docsIfUpChannelTxBackoffEnd,
docsIfUpChannelScdmaActiveCodes,
docsIfUpChannelScdmaCodesPerSlot,
docsIfUpChannelScdmaFrameSize,
docsIfUpChannelScdmaHoppingSeed,
docsIfUpChannelType,
docsIfUpChannelCloneFrom,
docsIfUpChannelUpdate,
docsIfUpChannelStatus,
docsIfUpChannelPreEqEnable,
docsIfQosProfPriority,
docsIfQosProfMaxUpBandwidth,
docsIfQosProfGuarUpBandwidth,
docsIfQosProfMaxDownBandwidth,
docsIfQosProfBaselinePrivacy,
docsIfQosProfStatus,
docsIfQosProfMaxTransmitBurst,
docsIfSigQIncludesContention,
docsIfSigQUnerroreds,
docsIfSigQCorrecteds,
docsIfSigQUncorrectables,
docsIfSigQSignalNoise,
docsIfSigQMicroreflections,
docsIfSigQEqualizationData,
docsIfSigQExtUnerroreds,
docsIfSigQExtCorrecteds,
docsIfSigQExtUncorrectables,
docsIfDocsisBaseCapability
}
STATUS current
DESCRIPTION
"Group of objects implemented in both Cable Modems and
Cable Modem Termination Systems."
::= { docsIfGroups 1 }
docsIfCmGroup OBJECT-GROUP
OBJECTS {
docsIfCmCmtsAddress,
docsIfCmCapabilities,
docsIfCmRangingTimeout,
-- docsIfCmRangingRespTimeout,
docsIfCmStatusValue,
docsIfCmStatusCode,
docsIfCmStatusTxPower,
docsIfCmStatusResets,
docsIfCmStatusLostSyncs,
docsIfCmStatusInvalidMaps,
docsIfCmStatusInvalidUcds,
docsIfCmStatusInvalidRangingResponses,
docsIfCmStatusInvalidRegistrationResponses,
docsIfCmStatusT1Timeouts,
docsIfCmStatusT2Timeouts,
docsIfCmStatusT3Timeouts,
docsIfCmStatusT4Timeouts,
docsIfCmStatusRangingAborteds,
docsIfCmStatusDocsisOperMode,
docsIfCmStatusModulationType,
docsIfCmStatusEqualizationData,
docsIfCmServiceQosProfile,
docsIfCmServiceTxSlotsImmed,
docsIfCmServiceTxSlotsDed,
docsIfCmServiceTxRetries,
docsIfCmServiceTxExceededs,
docsIfCmServiceRqRetries,
docsIfCmServiceRqExceededs,
docsIfCmServiceExtTxSlotsImmed,
docsIfCmServiceExtTxSlotsDed
}
STATUS current
DESCRIPTION
"Group of objects implemented in Cable Modems."
::= { docsIfGroups 2 }
docsIfCmtsGroup OBJECT-GROUP
OBJECTS {
docsIfCmtsCapabilities,
docsIfCmtsSyncInterval,
docsIfCmtsUcdInterval,
docsIfCmtsMaxServiceIds,
-- docsIfCmtsInsertionInterval,
docsIfCmtsInvitedRangingAttempts,
docsIfCmtsInsertInterval,
docsIfCmtsStatusInvalidRangeReqs,
docsIfCmtsStatusRangingAborteds,
docsIfCmtsStatusInvalidRegReqs,
docsIfCmtsStatusFailedRegReqs,
docsIfCmtsStatusInvalidDataReqs,
docsIfCmtsStatusT5Timeouts,
docsIfCmtsCmStatusMacAddress,
docsIfCmtsCmStatusDownChannelIfIndex,
docsIfCmtsCmStatusUpChannelIfIndex,
docsIfCmtsCmStatusRxPower,
docsIfCmtsCmStatusTimingOffset,
docsIfCmtsCmStatusEqualizationData,
docsIfCmtsCmStatusValue,
docsIfCmtsCmStatusUnerroreds,
docsIfCmtsCmStatusCorrecteds,
docsIfCmtsCmStatusUncorrectables,
docsIfCmtsCmStatusSignalNoise,
docsIfCmtsCmStatusMicroreflections,
docsIfCmtsCmStatusExtUnerroreds,
docsIfCmtsCmStatusExtCorrecteds,
docsIfCmtsCmStatusExtUncorrectables,
docsIfCmtsCmStatusDocsisRegMode,
docsIfCmtsCmStatusModulationType,
docsIfCmtsCmStatusInetAddressType,
docsIfCmtsCmStatusInetAddress,
docsIfCmtsCmStatusValueLastUpdate,
docsIfCmtsServiceAdminStatus,
docsIfCmtsServiceQosProfile,
docsIfCmtsServiceCreateTime,
docsIfCmtsServiceInOctets,
docsIfCmtsServiceInPackets,
docsIfCmtsServiceNewCmStatusIndex,
docsIfCmtsModType,
docsIfCmtsModControl,
docsIfCmtsModPreambleLen,
docsIfCmtsModDifferentialEncoding,
docsIfCmtsModFECErrorCorrection,
docsIfCmtsModFECCodewordLength,
docsIfCmtsModScramblerSeed,
docsIfCmtsModMaxBurstSize,
docsIfCmtsModGuardTimeSize,
docsIfCmtsModLastCodewordShortened,
docsIfCmtsModScrambler,
docsIfCmtsModByteInterleaverDepth,
docsIfCmtsModByteInterleaverBlockSize,
docsIfCmtsModPreambleType,
docsIfCmtsModTcmErrorCorrectionOn,
docsIfCmtsModScdmaInterleaverStepSize,
docsIfCmtsModScdmaSpreaderEnable,
docsIfCmtsModScdmaSubframeCodes,
docsIfCmtsModChannelType,
docsIfCmtsQosProfilePermissions,
docsIfCmtsCmPtr,
docsIfCmtsChannelUtilizationInterval,
docsIfCmtsChannelUtUtilization,
docsIfCmtsDownChnlCtrTotalBytes,
docsIfCmtsDownChnlCtrUsedBytes,
docsIfCmtsDownChnlCtrExtTotalBytes,
docsIfCmtsDownChnlCtrExtUsedBytes,
docsIfCmtsUpChnlCtrTotalMslots,
docsIfCmtsUpChnlCtrUcastGrantedMslots,
docsIfCmtsUpChnlCtrTotalCntnMslots,
docsIfCmtsUpChnlCtrUsedCntnMslots,
docsIfCmtsUpChnlCtrExtTotalMslots,
docsIfCmtsUpChnlCtrExtUcastGrantedMslots,
docsIfCmtsUpChnlCtrExtTotalCntnMslots,
docsIfCmtsUpChnlCtrExtUsedCntnMslots,
docsIfCmtsUpChnlCtrCollCntnMslots,
docsIfCmtsUpChnlCtrTotalCntnReqMslots,
docsIfCmtsUpChnlCtrUsedCntnReqMslots,
docsIfCmtsUpChnlCtrCollCntnReqMslots,
docsIfCmtsUpChnlCtrTotalCntnReqDataMslots,
docsIfCmtsUpChnlCtrUsedCntnReqDataMslots,
docsIfCmtsUpChnlCtrCollCntnReqDataMslots,
docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots,
docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots,
docsIfCmtsUpChnlCtrCollCntnInitMaintMslots,
docsIfCmtsUpChnlCtrExtCollCntnMslots,
docsIfCmtsUpChnlCtrExtTotalCntnReqMslots,
docsIfCmtsUpChnlCtrExtUsedCntnReqMslots,
docsIfCmtsUpChnlCtrExtCollCntnReqMslots,
docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots,
docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots,
docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots,
docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots,
docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots,
docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots
}
STATUS current
DESCRIPTION
"Group of objects implemented in Cable Modem Termination
Systems."
::= { docsIfGroups 3 }
docsIfObsoleteGroup OBJECT-GROUP
OBJECTS {
docsIfCmRangingRespTimeout,
docsIfCmtsInsertionInterval
}
STATUS obsolete
DESCRIPTION
"Group of objects obsoleted."
::= { docsIfGroups 4 }
docsIfDeprecatedGroup OBJECT-GROUP
OBJECTS {
docsIfQosProfMaxTxBurst,
docsIfCmtsCmStatusIpAddress,
docsIfCmtsServiceCmStatusIndex
}
STATUS deprecated
DESCRIPTION
"Group of objects deprecated."
::= { docsIfGroups 5 }
END