-- ALPINE-GEN-CARD-TDCM-MIB.mib
--
ALPINE-GEN-CARD-TDCM-MIB DEFINITIONS ::= BEGIN
IMPORTS
alpineGeneric
FROM ALPINE-ROOT
Integer32, OBJECT-TYPE
FROM SNMPv2-SMI;
--
-- Node definitions
--
-- 1.3.6.1.4.1.52326.1.2
alpineGenCardTdcm OBJECT IDENTIFIER ::= { alpineGeneric 2 }
-- 1.3.6.1.4.1.52326.1.2.1
alpineGenCardTdcmInfosTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlpineGenCardTdcmInfosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { alpineGenCardTdcm 1 }
-- 1.3.6.1.4.1.52326.1.2.1.1
alpineGenCardTdcmInfosEntry OBJECT-TYPE
SYNTAX AlpineGenCardTdcmInfosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
INDEX { gctiSlotNum }
::= { alpineGenCardTdcmInfosTable 1 }
AlpineGenCardTdcmInfosEntry ::=
SEQUENCE {
gctiSlotNum
Integer32,
gctiWorkMode
Integer32,
gctiDefaultDispersion
Integer32,
gctiCurrentDispersion
Integer32,
gctiAutoModeSwitch
Integer32,
gctiSaveConfig
Integer32
}
-- 1.3.6.1.4.1.52326.1.2.1.1.1
gctiSlotNum OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number."
::= { alpineGenCardTdcmInfosEntry 1 }
-- 1.3.6.1.4.1.52326.1.2.1.1.2
gctiWorkMode OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Work mode of TDCM.
1. Manual Mode.
2. Auto Mode."
::= { alpineGenCardTdcmInfosEntry 2 }
-- 1.3.6.1.4.1.52326.1.2.1.1.3
gctiDefaultDispersion OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm*km"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The default dipersion value for line card startup."
::= { alpineGenCardTdcmInfosEntry 3 }
-- 1.3.6.1.4.1.52326.1.2.1.1.4
gctiCurrentDispersion OBJECT-TYPE
SYNTAX Integer32
UNITS "ps/nm*km"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current dispersion setting."
::= { alpineGenCardTdcmInfosEntry 4 }
-- 1.3.6.1.4.1.52326.1.2.1.1.5
gctiAutoModeSwitch OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Turn on/off auto engine when current work mode is auto.
1. Turn on auto monitor and tunning for current monitor fiber.
2. Turn off auto monitor and tunning.
Note, this value is only available when current work mode 'gctiWorkMode' is auto."
::= { alpineGenCardTdcmInfosEntry 5 }
-- 1.3.6.1.4.1.52326.1.2.1.1.6
gctiSaveConfig OBJECT-TYPE
SYNTAX Integer32 (0..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Save current configuration into flash for non-valatile setting.
0: Idle/Save Done.
1: Issue save command.
2: Saving.
Only value 1 can be accepted in snmp set."
::= { alpineGenCardTdcmInfosEntry 6 }
END
--
-- ALPINE-GEN-CARD-TDCM-MIB.mib
--