-- Title: BWA Private MIB
|
|
-- This Private MIB supports BWA-PtMP and BWA-PtP product lines.
|
|
--
|
|
--
|
|
-- Version: 4.5.16
|
|
-- Date: Tuesday August 14 2007
|
|
-- Comments: BWA agents also support the following Public MIBs:
|
|
|
|
-- This MIB supports BWA VL products (AU and SU),
|
|
-- BWA 4900 (AU and SU) and
|
|
-- BWA-PtP products (BU and RB).
|
|
|
|
-- Some MIB compilers require that the following lines
|
|
-- for proper compilation
|
|
|
|
--#include "rfc1155.smi"
|
|
--#include "rfc1212.smi"
|
|
|
|
|
|
-- mgmt OBJECT IDENTIFIER ::= { iso org(3) dod(6) internet(1) mgmt(2) }
|
|
-- mib OBJECT IDENTIFIER ::= { mgmt 1 }
|
|
-- directory OBJECT IDENTIFIER ::= { internet 1 }
|
|
-- experimental OBJECT IDENTIFIER ::= { internet 3 }
|
|
-- private OBJECT IDENTIFIER ::= { internet 4 }
|
|
-- enterprises OBJECT IDENTIFIER ::= { private 1 }
|
|
|
|
-- End of lines which might be needed to other MIB browsers
|
|
-- for proper compilation
|
|
|
|
|
|
BWA-DOT11-WLAN-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, NOTIFICATION-TYPE, enterprises, IpAddress,Counter32,OBJECT-TYPE
|
|
FROM SNMPv2-SMI;
|
|
|
|
bwa OBJECT IDENTIFIER ::= { enterprises 12394 }
|
|
products OBJECT IDENTIFIER ::= { bwa 1 }
|
|
|
|
bwaVLMib MODULE-IDENTITY
|
|
LAST-UPDATED "0708141146Z"
|
|
ORGANIZATION "BWA Products"
|
|
CONTACT-INFO "Contact Man
|
|
Postal: BWA Products
|
|
Street Number ZipCode
|
|
Country
|
|
Tel: 000-0-0000000
|
|
Fax: 000-0-0000000
|
|
E-mail: E-mail"
|
|
DESCRIPTION
|
|
"BWA VL products, BWA 4900, BWA-PtP"
|
|
REVISION "0708141146Z"
|
|
DESCRIPTION
|
|
"Version 4.5"
|
|
::= { products 1 }
|
|
|
|
|
|
MacAddress ::= OCTET STRING (SIZE(6))
|
|
DisplayString ::= OCTET STRING
|
|
|
|
bwaOID OBJECT IDENTIFIER ::= { bwa 4 }
|
|
bwaVLOID OBJECT IDENTIFIER ::= { bwaOID 1 }
|
|
|
|
|
|
bwaVLAU OBJECT IDENTIFIER ::= { bwaVLOID 1 }
|
|
bwaVLSU OBJECT IDENTIFIER ::= { bwaVLOID 2 }
|
|
|
|
bwaVLAU-BS OBJECT IDENTIFIER ::= { bwaVLOID 4 }
|
|
bwaVLAU-SA OBJECT IDENTIFIER ::= { bwaVLOID 5 }
|
|
|
|
bwaVLAUS-BS OBJECT IDENTIFIER ::= { bwaVLOID 6 }
|
|
bwaVLAUS-SA OBJECT IDENTIFIER ::= { bwaVLOID 7 }
|
|
bwaVLAU-EZ OBJECT IDENTIFIER ::= { bwaVLOID 8 }
|
|
|
|
|
|
bwaVLSU-6-1D OBJECT IDENTIFIER ::= { bwaVLOID 11 }
|
|
bwaVLSU-6-BD OBJECT IDENTIFIER ::= { bwaVLOID 12 }
|
|
bwaVLSU-24-BD OBJECT IDENTIFIER ::= { bwaVLOID 13 }
|
|
bwaVLSU-BD OBJECT IDENTIFIER ::= { bwaVLOID 14 }
|
|
bwaVLSU-54-BD OBJECT IDENTIFIER ::= { bwaVLOID 15 }
|
|
|
|
bwaVLSU-3-1D OBJECT IDENTIFIER ::= { bwaVLOID 16 }
|
|
bwaVLSU-3-4D OBJECT IDENTIFIER ::= { bwaVLOID 17 }
|
|
bwaVLSU-I OBJECT IDENTIFIER ::= { bwaVLOID 18 }
|
|
|
|
|
|
ptp-BU-B14 OBJECT IDENTIFIER ::= { bwaVLOID 21 }
|
|
ptp-BU-B28 OBJECT IDENTIFIER ::= { bwaVLOID 22 }
|
|
ptp-BU-B100 OBJECT IDENTIFIER ::= { bwaVLOID 23 }
|
|
|
|
ptp-RB-B14 OBJECT IDENTIFIER ::= { bwaVLOID 31 }
|
|
ptp-RB-B28 OBJECT IDENTIFIER ::= { bwaVLOID 32 }
|
|
ptp-RB-B100 OBJECT IDENTIFIER ::= { bwaVLOID 33 }
|
|
|
|
bwa4900-AU-BS OBJECT IDENTIFIER ::= { bwaVLOID 41 }
|
|
bwa4900-AU-SA OBJECT IDENTIFIER ::= { bwaVLOID 42 }
|
|
bwa4900-SU-BD OBJECT IDENTIFIER ::= { bwaVLOID 51 }
|
|
|
|
bwaVLProducts OBJECT IDENTIFIER ::= { bwaVLOID 3 }
|
|
|
|
-- ****************************************************************************************
|
|
-- ****************************************************************************************
|
|
-- General System Info
|
|
-- ===================
|
|
bwaVLSysInfo OBJECT IDENTIFIER ::= {bwaVLMib 1}
|
|
|
|
|
|
bwaVLUnitHwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Hardware platform version."
|
|
::= { bwaVLSysInfo 1 }
|
|
|
|
bwaVLRunningSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Running software version."
|
|
::= { bwaVLSysInfo 2 }
|
|
|
|
bwaVLRunningFrom OBJECT-TYPE
|
|
SYNTAX INTEGER { mainVersion(1) , shadowVersion(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The memory (main or shadow) from which the current version is
|
|
running from."
|
|
::= { bwaVLSysInfo 3 }
|
|
|
|
bwaVLMainVersionNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Main software version number."
|
|
::= { bwaVLSysInfo 4 }
|
|
|
|
bwaVLMainVersionFileName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Main software version file name."
|
|
::= { bwaVLSysInfo 5 }
|
|
|
|
|
|
bwaVLShadowVersionNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Shadow software version number."
|
|
::= { bwaVLSysInfo 6 }
|
|
|
|
bwaVLShadowVersionFileName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Shadow software version file name."
|
|
::= { bwaVLSysInfo 7 }
|
|
|
|
bwaVLUnitMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Unit hardware MAC address."
|
|
::= { bwaVLSysInfo 8 }
|
|
|
|
bwaVLUnitType OBJECT-TYPE
|
|
SYNTAX INTEGER {auBS (1), auSA(2) , su-6-1D(3),su-6-BD(4),su-24-BD(5),
|
|
bu-B14(6),bu-B28(7),rb-B14(8),rb-B28(9),su-BD(10),su-54-BD (11),
|
|
su-3-1D(12),su-3-4D(13),ausBS(14),ausSA(15),
|
|
auBS4900(16),auSA4900(17),su4900(18), bu-B100(19), rb-B100(20), su-I(21),
|
|
au-E(22) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
auBS (1) : AU-BS (modular access unit).
|
|
auSA (2) : AU-SA (stand-alone access unit).
|
|
su-6-1D (3) : SU-6-1D (subscriber unit supporting 6 Mbps)
|
|
su-6-BD (4) : SU-6-BD (subscriber unit supporting 6 Mbps).
|
|
su-24-BD (5) : SU-24-BD (subscriber unit supporting 24 Mbps).
|
|
bu-B14 (6) : BU-B14 (PtP Base Unit supporting 14 Mbps).
|
|
bu-B28 (7) : BU-B28 (PtP Base Unit supporting 28 Mbps).
|
|
rb-B14 (8) : RB-B14 (PtP Remote Bridge supporting 14 Mbps).
|
|
rb-B28 (9) : RB-B28 (PtP Remote Bridge supporting 28 Mbps).
|
|
su-BD (10) : SU-BD (subscriber unit).
|
|
su-54-BD(11) : SU-54-BD (subscriber unit supporting 54 Mbps).
|
|
su-3-1D (12) : SU-3-1D (subscriber unit supporting 3 Mbps).
|
|
su-3-4D (13) : SU-3-4D (subscriber unit supporting 3 Mbps).
|
|
ausBS (14) : AUS-BS (modular access unit supporting maxim 8 or 25
|
|
(via licensing) subscribers and allowing association
|
|
only with SU-3 or SU-6).
|
|
ausSA (15) : AUS-SA (stand-alone access unit supporting maxim 8 or 25
|
|
(via licensing)subscribers and allowing association only
|
|
with SU-3 or SU-6 ).
|
|
auBS4900(16) : AU-BS-4900 (BWA 4900 modular access unit)
|
|
auSA4900(17) : AU-SA-4900 (BWA 4900 stand alone access unit)
|
|
suBD4900(18) : SU-BD-4900 (BWA 4900 subscriber unit)
|
|
bu-B100 (19) : BU-B100 (PtP Base Unit unlimited throughput)
|
|
rb-B100 (20) : BU-B100 (PtP Remote Bridge unlimited throughput)
|
|
su-I (21) : SU-I
|
|
au-E (22) : AU-E"
|
|
::= { bwaVLSysInfo 9 }
|
|
|
|
bwaVLAssociatedAU OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Associated AU/BU MAC address."
|
|
::= { bwaVLSysInfo 10 }
|
|
|
|
bwaVLNumOfAssociationsSinceLastReset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The number of associations since last reset, including
|
|
duplicate associations (re-associations)."
|
|
::= { bwaVLSysInfo 11 }
|
|
|
|
bwaVLCurrentNumOfAssociations OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP products.
|
|
The number of SUs currently associated with the AU.
|
|
BWA-PtP products return 65535."
|
|
::= { bwaVLSysInfo 13 }
|
|
|
|
bwaVLUnitBootVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Boot version."
|
|
::= { bwaVLSysInfo 14 }
|
|
|
|
bwaVLRadioBand OBJECT-TYPE
|
|
SYNTAX INTEGER {band-5-8GHz (1), band-5-4GHz (2) , band-4-9GHz (3),band-5-2GHz (4),band-2-4GHz (5),band-5-3GHz (6),band-4-9GHzJapan (7)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The unit's radio band."
|
|
::= { bwaVLSysInfo 15 }
|
|
|
|
bwaVLCurrentEthernetPortState OBJECT-TYPE
|
|
SYNTAX INTEGER { halfDuplexAnd10Mbps (1),
|
|
fullDuplexAnd10Mbps (2),
|
|
halfDuplexAnd100Mbps (3),
|
|
fullDuplexAnd100Mbps (4),
|
|
linkDown (5) }
|
|
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The current Ethernet port state."
|
|
::= { bwaVLSysInfo 16 }
|
|
|
|
|
|
|
|
bwaVLTimeSinceLastReset OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The elapsed time since last reset."
|
|
::= { bwaVLSysInfo 17 }
|
|
|
|
bwaVLCountryDependentParameters OBJECT IDENTIFIER ::= {bwaVLSysInfo 18}
|
|
|
|
bwaVLCountryCode OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The country code and country name or country group name
|
|
that is supported by the unit."
|
|
::= { bwaVLCountryDependentParameters 1 }
|
|
|
|
bwaVLCountryDependentParamsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLCountryDependentParameterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. A table of country dependent parameters."
|
|
::= {bwaVLCountryDependentParameters 2}
|
|
|
|
bwaVLCountryDependentParameterEntry OBJECT-TYPE
|
|
SYNTAX BwaVLCountryDependentParameterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
An entry in the Country Dependent Parameters table."
|
|
INDEX { bwaVLCountryDependentParameterTableIdx }
|
|
::= { bwaVLCountryDependentParamsTable 1 }
|
|
|
|
BwaVLCountryDependentParameterEntry ::= SEQUENCE {
|
|
bwaVLCountryDependentParameterTableIdx INTEGER,
|
|
bwaVLCountryDependentParameterFrequencies DisplayString,
|
|
bwaVLAllowedBandwidth INTEGER,
|
|
bwaVLRegulationMaxTxPowerAtAntennaPort INTEGER,
|
|
bwaVLRegulationMaxEIRP INTEGER,
|
|
bwaVLMinModulationLevel INTEGER,
|
|
bwaVLMaxModulationLevel INTEGER,
|
|
bwaVLBurstModeSupport INTEGER,
|
|
bwaVLMaximumBurstDuration INTEGER,
|
|
bwaVLDfsSupport INTEGER,
|
|
bwaVLMinimumHwRevision INTEGER
|
|
}
|
|
|
|
bwaVLCountryDependentParameterTableIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..5)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The sub-band ID of the entry in the Country Dependent
|
|
Parameters table. Serves also as index for the table entry."
|
|
::= { bwaVLCountryDependentParameterEntry 1 }
|
|
|
|
bwaVLCountryDependentParameterFrequencies OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The frequencies included in the applicable sub-band entry."
|
|
::= { bwaVLCountryDependentParameterEntry 2 }
|
|
|
|
bwaVLAllowedBandwidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The bandwidth when using the applicable the sub-band."
|
|
::= { bwaVLCountryDependentParameterEntry 3 }
|
|
|
|
bwaVLRegulationMaxTxPowerAtAntennaPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The maximum allowed Tx power when using the applicable sub-band.
|
|
A RegulationMaxTxPowerAtAntennaPort of 255, means no limit"
|
|
::= { bwaVLCountryDependentParameterEntry 4 }
|
|
|
|
bwaVLRegulationMaxEIRP OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The maximum Tx EIRP
|
|
when using the applicable sub-band.
|
|
A Regulation Max EIRP of 0, means no limit."
|
|
::= { bwaVLCountryDependentParameterEntry 5 }
|
|
|
|
|
|
bwaVLMinModulationLevel OBJECT-TYPE
|
|
SYNTAX INTEGER { level1 (1),
|
|
level2 (2),
|
|
level3 (3),
|
|
level4 (4),
|
|
level5 (5),
|
|
level6 (6),
|
|
level7 (7),
|
|
level8 (8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The minimum supported modulation level."
|
|
::= { bwaVLCountryDependentParameterEntry 6 }
|
|
|
|
bwaVLMaxModulationLevel OBJECT-TYPE
|
|
SYNTAX INTEGER { level1 (1),
|
|
level2 (2),
|
|
level3 (3),
|
|
level4 (4),
|
|
level5 (5),
|
|
level6 (6),
|
|
level7 (7),
|
|
level8 (8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The maximum supported modulation level."
|
|
::= { bwaVLCountryDependentParameterEntry 7 }
|
|
|
|
bwaVLBurstModeSupport OBJECT-TYPE
|
|
SYNTAX INTEGER {supported(1), notSupported(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The supported Burst Mode Option."
|
|
::= { bwaVLCountryDependentParameterEntry 8}
|
|
|
|
bwaVLMaximumBurstDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Applicable only if Burst Mode Option is supported.
|
|
The maximum supported burst duration."
|
|
::= { bwaVLCountryDependentParameterEntry 9}
|
|
|
|
|
|
bwaVLDfsSupport OBJECT-TYPE
|
|
SYNTAX INTEGER {supported(1), notSupported(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The supported Dfs Option."
|
|
::= { bwaVLCountryDependentParameterEntry 10}
|
|
|
|
bwaVLMinimumHwRevision OBJECT-TYPE
|
|
SYNTAX INTEGER {hwRevisionA (1), hwRevisionB (2),
|
|
hwRevisionC (3), hwRevisionD (4),
|
|
hwRevisionE (5), na (255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The Minimum HW Revision needed to support the country code."
|
|
::= { bwaVLCountryDependentParameterEntry 11}
|
|
|
|
|
|
bwaVLAuthenticationEncryptionSupport OBJECT-TYPE
|
|
SYNTAX INTEGER {supported(1), notSupported(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The supported Authentication Encryption Option."
|
|
::= { bwaVLCountryDependentParameters 3 }
|
|
|
|
bwaVLDataEncryptionSupport OBJECT-TYPE
|
|
SYNTAX INTEGER {supported(1), notSupported(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The supported Data Encryption Option."
|
|
::= { bwaVLCountryDependentParameters 4 }
|
|
|
|
bwaVLAESEncryptionSupport OBJECT-TYPE
|
|
SYNTAX INTEGER {supported(1), notSupported(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The supported AES Encryption Option."
|
|
::= { bwaVLCountryDependentParameters 5 }
|
|
|
|
bwaVLAntennaGainChange OBJECT-TYPE
|
|
SYNTAX INTEGER {supported(1), notSupported(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Indicates whether the Antenna Gain parameter is changeable or fixed."
|
|
::= { bwaVLSysInfo 19 }
|
|
|
|
bwaVLAteTestResults OBJECT-TYPE
|
|
SYNTAX INTEGER { none(0), pass(1), fail(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Results of ATE Test "
|
|
::= { bwaVLSysInfo 20 }
|
|
|
|
bwaVLSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..35))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Serial Number of the unit"
|
|
::= { bwaVLSysInfo 21 }
|
|
|
|
-- Unit Control
|
|
-- ============
|
|
bwaVLUnitControl OBJECT IDENTIFIER ::= {bwaVLMib 2}
|
|
|
|
bwaVLResetUnit OBJECT-TYPE
|
|
SYNTAX INTEGER { cancel (1), resetSystemNow (2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Resets the unit and applies new parameter values."
|
|
::= { bwaVLUnitControl 1 }
|
|
|
|
|
|
bwaVLSetDefaults OBJECT-TYPE
|
|
SYNTAX INTEGER { noDefaultSettingRequested (0),
|
|
completeFactory (1),
|
|
partialFactory (2),
|
|
completeOperator (3),
|
|
partialOperator (4),
|
|
cancelCurrentPendingRequest(5) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Sets unit configuration to Defaults values after the
|
|
next reset.
|
|
noDefaultSettingRequested : Read-Only Option, no Default setting was Issued.
|
|
completeFactory : All parameters revert to Factory
|
|
Defaults values.
|
|
partialFactory : All parameters revert to Factory
|
|
Defaults values, except the parameters
|
|
required for maintaining wireless
|
|
connectivity.
|
|
completeOperator: All parameters revert to Operator
|
|
Defaults values.
|
|
partialOperator : All parameters revert to Operator
|
|
Defaults values, except the parameters
|
|
required for maintaining wireless
|
|
connectivity.
|
|
cancelCurrentPendingRequest : Default Setting request is cancelled."
|
|
::= { bwaVLUnitControl 2 }
|
|
|
|
bwaVLUnitName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The unit name.
|
|
A string of up to 32 printable ASCII characters."
|
|
::= { bwaVLUnitControl 3 }
|
|
|
|
bwaVLFlashMemoryControl OBJECT-TYPE
|
|
SYNTAX INTEGER { resetAndBootFromShadowVersion (1),
|
|
useRunningVersionAfterReset (2),cancel(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
resetAndBootFromShadowVersion : Activates the backup
|
|
version.
|
|
useRunningVersionAfterReset : The currently active
|
|
version will become the main
|
|
version and will be activated
|
|
after next reset."
|
|
::= { bwaVLUnitControl 4 }
|
|
|
|
|
|
bwaVLTelnetLogoutTimer OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Time-out of management via Telnet program.
|
|
Automatic exit if the program is inactive for the
|
|
defined time.
|
|
Range: 1 to 999 (minutes)."
|
|
::= { bwaVLUnitControl 5 }
|
|
|
|
bwaVLSaveCurrentConfigurationAsOperatorDefaults OBJECT-TYPE
|
|
SYNTAX INTEGER { saveAsDefaults (1),cancel(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Saves the current configuration as Operator Defaults.
|
|
Cannot be executed after requesting set defaults
|
|
and the unit was not reset."
|
|
::= { bwaVLUnitControl 6 }
|
|
|
|
bwaVLExitTelnet OBJECT-TYPE
|
|
SYNTAX INTEGER { cancelOperation (1), exit (2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Exit the management via Telnet program."
|
|
::= { bwaVLUnitControl 7 }
|
|
|
|
bwaVLUnitPasswords OBJECT IDENTIFIER ::= {bwaVLUnitControl 8}
|
|
|
|
bwaVLReadOnlyPassword OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..8))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The User (read only) password.
|
|
This is also the Read Community String.
|
|
Up to 8 printable ASCII characters."
|
|
::= { bwaVLUnitPasswords 1 }
|
|
|
|
bwaVLInstallerPassword OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..8))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The Installer password.
|
|
Up to 8 printable ASCII characters."
|
|
::= { bwaVLUnitPasswords 2 }
|
|
|
|
bwaVLAdminPassword OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..8))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The Administrator password. Accessible only with SNMP Write
|
|
Community String (administrator password).
|
|
Up to 8 printable ASCII characters."
|
|
::= { bwaVLUnitPasswords 3 }
|
|
|
|
|
|
bwaVLEthernetNegotiationMode OBJECT-TYPE
|
|
SYNTAX INTEGER { force10MbpsAndHalfDuplex (1),
|
|
force10MbpsAndFullDuplex (2),
|
|
force100MbpsAndHalfDuplex (3),
|
|
force100MbpsAndFullDuplex (4),
|
|
autoNegotiationMode (5) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The speed/duplex mode of the Ethernet port."
|
|
::= { bwaVLUnitControl 9 }
|
|
|
|
bwaVLFTPParameters OBJECT IDENTIFIER ::= {bwaVLUnitControl 10}
|
|
|
|
bwaVLFTPServerParams OBJECT IDENTIFIER ::= {bwaVLFTPParameters 1}
|
|
|
|
bwaVLFTPServerUserName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..18))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The user name to be used for access to the FTP server.
|
|
Accessible only with SNMP Write Community String
|
|
(administrator password)."
|
|
::= { bwaVLFTPServerParams 1 }
|
|
|
|
bwaVLFTPServerPassword OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..18))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The password to be used for access to the FTP server.
|
|
Accessible only with SNMP Write Community String
|
|
(administrator password)."
|
|
::= { bwaVLFTPServerParams 2 }
|
|
|
|
bwaVLFTPClientIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
For SW version higher than 4.0 this is read-only.
|
|
The IP address of the FTP stack in the unit."
|
|
::= { bwaVLFTPServerParams 3 }
|
|
|
|
bwaVLFTPServerIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The IP address of the FTP server."
|
|
::= { bwaVLFTPServerParams 4 }
|
|
|
|
bwaVLFTPClientMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The Mask of the FTP stack in the unit."
|
|
::= { bwaVLFTPServerParams 5 }
|
|
|
|
|
|
bwaVLFTPGatewayIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The FTP Gateway address"
|
|
::= { bwaVLFTPServerParams 6 }
|
|
|
|
|
|
bwaVLFTPSwDownload OBJECT IDENTIFIER ::= {bwaVLFTPParameters 2}
|
|
|
|
bwaVLFTPSwFileName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..20))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The name of the SW file to be downloaded."
|
|
::= { bwaVLFTPSwDownload 1 }
|
|
|
|
bwaVLFTPSwSourceDir OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..80))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The source directory of the required file in the FTP server.
|
|
Up to 80 printable ASCII characters.
|
|
Use dot (.) To clear field"
|
|
::= { bwaVLFTPSwDownload 2 }
|
|
|
|
bwaVLFTPDownloadSwFile OBJECT-TYPE
|
|
SYNTAX INTEGER { downloadFile (1) , cancel (2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Execution of the SW download operation"
|
|
::= { bwaVLFTPSwDownload 3 }
|
|
|
|
bwaVLConfigurationFileLoading OBJECT IDENTIFIER ::= {bwaVLFTPParameters 3}
|
|
|
|
bwaVLConfigurationFileName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..20))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The name of the configuration file to be downloaded/uploaded."
|
|
::= { bwaVLConfigurationFileLoading 1 }
|
|
|
|
bwaVLOperatorDefaultsFileName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..20))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The name of the Operator Defaults file to be downloaded/uploaded"
|
|
::= { bwaVLConfigurationFileLoading 2 }
|
|
|
|
bwaVLFTPConfigurationFileSourceDir OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..80))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The source directory of the required file in the FTP server.
|
|
Up to 80 printable ASCII characters.
|
|
Use dot (.) To clear field"
|
|
::= { bwaVLConfigurationFileLoading 3 }
|
|
|
|
bwaVLExecuteFTPConfigurationFileLoading OBJECT-TYPE
|
|
SYNTAX INTEGER {executeFTPGetConfigurationFile (1), executeFTPPutConfigurationFile (2),
|
|
executeFTPGetOperatorDefaults (3) , executeFTPPutOperatorDefaults (4), cancel (5) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Execution of the file download/upload operation."
|
|
::= { bwaVLConfigurationFileLoading 4 }
|
|
|
|
|
|
|
|
bwaVLEventLogFileUploading OBJECT IDENTIFIER ::= {bwaVLFTPParameters 4}
|
|
|
|
bwaVLEventLogFileName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..20))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The name of the Event Log file to be uploaded."
|
|
::= { bwaVLEventLogFileUploading 1 }
|
|
|
|
bwaVLEventLogDestinationDir OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..80))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The destination directory of the event log file.
|
|
Up to 80 printable ASCII characters.
|
|
Use dot (.) To clear field."
|
|
::= { bwaVLEventLogFileUploading 2 }
|
|
|
|
bwaVLUploadEventLogFile OBJECT-TYPE
|
|
SYNTAX INTEGER { uploadFile (1) , cancel (2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Execution of the event log upload operation."
|
|
::= { bwaVLEventLogFileUploading 3 }
|
|
|
|
bwaVLLoadingStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {inProcess (1), successful (2), failed (3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The status of the last loading operation."
|
|
::= { bwaVLUnitControl 11 }
|
|
|
|
bwaVLEventLogFileParams OBJECT IDENTIFIER ::= {bwaVLUnitControl 12}
|
|
|
|
bwaVLEventLogPolicy OBJECT-TYPE
|
|
SYNTAX INTEGER {message (1), warning (2), error (3),fatal(4), logNone(5)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The lowest level event to be registered in the event log."
|
|
::= { bwaVLEventLogFileParams 1 }
|
|
|
|
bwaVLEraseEventLog OBJECT-TYPE
|
|
SYNTAX INTEGER { eraseEventLog (1),cancel(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Erase the event log."
|
|
::= { bwaVLEventLogFileParams 2 }
|
|
|
|
bwaVLSystemLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..34))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The unit location."
|
|
::= { bwaVLUnitControl 13 }
|
|
|
|
bwaVLFeatureUpgrade OBJECT IDENTIFIER ::= {bwaVLUnitControl 14}
|
|
|
|
bwaVLFeatureUpgradeManually OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(32..64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Upgrade unit to support new feature. Enter your license number
|
|
(32 to 64 hex digits)."
|
|
::= { bwaVLFeatureUpgrade 1 }
|
|
|
|
bwaVLChangeUnitType OBJECT-TYPE
|
|
SYNTAX INTEGER { bu(1), rb(2), cancel(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable RB/BU only.
|
|
Change the unit type between BU and RB."
|
|
::= { bwaVLUnitControl 15 }
|
|
|
|
bwaLighteAPWorkingMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Change unit running mode: 0 - VL mode 1 - Mixed cell mode"
|
|
::= { bwaVLUnitControl 16 }
|
|
|
|
|
|
-- Network Management Params
|
|
-- =========================
|
|
bwaVLNwMngParameters OBJECT IDENTIFIER ::= {bwaVLMib 3}
|
|
|
|
bwaVLAccessToNwMng OBJECT-TYPE
|
|
SYNTAX INTEGER { fromWirelessOnly (1),
|
|
fromEthernetOnly (2),
|
|
fromBothWirelessAndEthernet (3),
|
|
na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The port to be used for remote management."
|
|
::= { bwaVLNwMngParameters 1 }
|
|
|
|
|
|
bwaVLNwMngFilter OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1),
|
|
activateOnEthernetPort (2),
|
|
activateOnWirelessPort (3),
|
|
activateOnBothWirelessAndEthernet (4),
|
|
na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Disables or enable on one of the ports, or on both
|
|
ports, IP address based filtering of management messages
|
|
(e.g. SNMP , Telnet , TFTP , DHCP)."
|
|
::= { bwaVLNwMngParameters 2 }
|
|
|
|
|
|
|
|
|
|
mngIpFilterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MngIpFilterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
A Management IP Filter Table of up to 3 IP addresses
|
|
of devices that are authorized to access the unit
|
|
for management purposes."
|
|
::= { bwaVLNwMngParameters 3 }
|
|
|
|
mngIpFilterEntry OBJECT-TYPE
|
|
SYNTAX MngIpFilterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
A Management IP Filter Table entry."
|
|
INDEX { bwaVLNwMngIpTableIdx }
|
|
::= { mngIpFilterTable 1 }
|
|
|
|
MngIpFilterEntry ::= SEQUENCE { bwaVLNwMngIpAddress IpAddress,
|
|
bwaVLNwMngIpTableIdx INTEGER }
|
|
|
|
bwaVLNwMngIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
An IP address in the Management IP Filter Table."
|
|
::= { mngIpFilterEntry 1 }
|
|
|
|
bwaVLNwMngIpTableIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..10)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
A table index for an entry in the Management IP Filter
|
|
Table."
|
|
::= { mngIpFilterEntry 2 }
|
|
|
|
|
|
bwaVLDeleteOneNwIpAddr OBJECT-TYPE
|
|
SYNTAX INTEGER (0 | 1..10 | 255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
0 - cancel operation.
|
|
1..10 - Deletes a single selected entry from the Management IP
|
|
Filter Table."
|
|
::= { bwaVLNwMngParameters 4 }
|
|
|
|
bwaVLDeleteAllNwIpAddrs OBJECT-TYPE
|
|
SYNTAX INTEGER { deleteAll (1), cancelOperation (2), na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Deletes all entries from the Management IP Filter Table."
|
|
::= { bwaVLNwMngParameters 5 }
|
|
|
|
bwaVLAccessToNwTrap OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(1), enable(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Enables or disables sending of traps."
|
|
::= { bwaVLNwMngParameters 6 }
|
|
|
|
mngTrapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MngTrapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
A Management Trap Table of up to 10 IP addresses of
|
|
stations to send traps to."
|
|
::= { bwaVLNwMngParameters 7 }
|
|
|
|
mngTrapEntry OBJECT-TYPE
|
|
SYNTAX MngTrapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
A Management Trap Table entry."
|
|
INDEX { bwaVLNwTrapTableIdx }
|
|
::= { mngTrapTable 1 }
|
|
|
|
MngTrapEntry ::= SEQUENCE { bwaVLNwMngTrapCommunity DisplayString,
|
|
bwaVLNwMngTrapAddress IpAddress,
|
|
bwaVLNwTrapTableIdx INTEGER }
|
|
|
|
bwaVLNwMngTrapCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..14))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The trap community associated with the applicable
|
|
entry in the Management Trap Table.
|
|
Up to 14 printable case sensitive ASCII characters."
|
|
::= { mngTrapEntry 1 }
|
|
|
|
bwaVLNwMngTrapAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
An IP address in the Management Trap Table entry."
|
|
::= { mngTrapEntry 2 }
|
|
|
|
bwaVLNwTrapTableIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..10)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Tables Index for an entry in the Management Trap Table."
|
|
::= { mngTrapEntry 3 }
|
|
|
|
|
|
bwaVLDeleteOneTrapAddr OBJECT-TYPE
|
|
SYNTAX INTEGER (0 | 1..10 | 255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
0 - cancel operation.
|
|
1..10 - Deletes a single selected entry from the Management
|
|
Trap Table."
|
|
::= { bwaVLNwMngParameters 8 }
|
|
|
|
|
|
bwaVLDeleteAllTrapAddrs OBJECT-TYPE
|
|
SYNTAX INTEGER { deleteAll (1),cancelOperation (2), na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Deletes all entries from the Management Trap Table."
|
|
::= { bwaVLNwMngParameters 9 }
|
|
|
|
bwaVLMngIpRangesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLMngIpRangeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Table of Management IP Address Ranges"
|
|
::= { bwaVLNwMngParameters 10 }
|
|
|
|
bwaVLMngIpRangeEntry OBJECT-TYPE
|
|
SYNTAX BwaVLMngIpRangeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
A Management IP Address Ranges Table entry"
|
|
INDEX { bwaVLMngIpRangeIdx }
|
|
::= { bwaVLMngIpRangesTable 1 }
|
|
|
|
BwaVLMngIpRangeEntry ::= SEQUENCE {
|
|
bwaVLMngIpRangeIdx INTEGER,
|
|
bwaVLMngIpRangeFlag INTEGER,
|
|
bwaVLMngIpRangeStart IpAddress,
|
|
bwaVLMngIpRangeEnd IpAddress,
|
|
bwaVLMngIpRangeMask IpAddress
|
|
}
|
|
|
|
|
|
bwaVLMngIpRangeIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..10)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Index of an entry in the Management IP Address Ranges Table"
|
|
::= { bwaVLMngIpRangeEntry 1 }
|
|
|
|
bwaVLMngIpRangeFlag OBJECT-TYPE
|
|
SYNTAX INTEGER { rangeDefinedByStartEndAddr(1), rangeDefinedByStartAddrMask(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Defines the method of defining the range:
|
|
Using Start & End Address( rangeDefinedByStartEndAddr ),
|
|
or using Start Address and Mask ( rangeDefinedByStartAddrSubNetMask )."
|
|
::= { bwaVLMngIpRangeEntry 2 }
|
|
|
|
|
|
bwaVLMngIpRangeStart OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Start Address of the range"
|
|
::= { bwaVLMngIpRangeEntry 3 }
|
|
|
|
bwaVLMngIpRangeEnd OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
End Address of the range.
|
|
Used only if bwaVLMngIpRangeFlag is rangeDefinedByStartEndAddr"
|
|
::= { bwaVLMngIpRangeEntry 4 }
|
|
|
|
bwaVLMngIpRangeMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
End Address of the range.
|
|
Used only if bwaVLMngIpRangeFlag is rangeDefinedByStartAddrMask"
|
|
::= { bwaVLMngIpRangeEntry 5 }
|
|
|
|
bwaVLDeleteOneNwIpRange OBJECT-TYPE
|
|
SYNTAX INTEGER (0 | 1..10 | 255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
0 - cancel operation.
|
|
1..10 - Deletes a single selected entry from the Management IP
|
|
Ranges Table."
|
|
::= { bwaVLNwMngParameters 11 }
|
|
|
|
|
|
bwaVLDeleteAllNwIpRanges OBJECT-TYPE
|
|
SYNTAX INTEGER { deleteAll (1), cancelOperation (2), na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Deletes all entries from the Management IP Ranges Table."
|
|
::= { bwaVLNwMngParameters 12 }
|
|
|
|
bwaVLApClientIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB unit only.
|
|
The IP Address of the WIFI WIMAX unit"
|
|
::= { bwaVLNwMngParameters 13 }
|
|
|
|
-- IP Params:
|
|
-- ===========
|
|
bwaVLIpParams OBJECT IDENTIFIER ::= {bwaVLMib 4}
|
|
|
|
bwaVLUnitIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
IP address of the unit."
|
|
::= { bwaVLIpParams 1 }
|
|
|
|
bwaVLSubNetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Subnet mask of the unit."
|
|
::= { bwaVLIpParams 2 }
|
|
|
|
bwaVLDefaultGWAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Default gateway IP address of the unit."
|
|
::= { bwaVLIpParams 3 }
|
|
|
|
bwaVLUseDhcp OBJECT-TYPE
|
|
SYNTAX INTEGER{ disable (1),
|
|
dhcpOnly (2),
|
|
automatic (3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
DHCP client mode of operation.
|
|
disabled : Use regular (manual) methods to configure IP
|
|
parameters.
|
|
dHCP Only: Use DHCP server to configure IP parameters.
|
|
automatic: Use DHCP server to configure IP parameters.
|
|
If a DHCP server is not available, use
|
|
manually configured values."
|
|
::= { bwaVLIpParams 4 }
|
|
|
|
bwaVLAccessToDHCP OBJECT-TYPE
|
|
SYNTAX INTEGER{ fromWirelessOnly (1),
|
|
fromEthernetOnly (2),
|
|
fromBothWirelessAndEthernet (3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The port to be used for communicating with a DHCP server."
|
|
::= { bwaVLIpParams 5 }
|
|
|
|
bwaVLRunTimeIPaddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The run-time IP address. If DHCP is used the Run Time
|
|
IP Address is the address given to the unit by the
|
|
server. Otherwise it is the manually configured address."
|
|
::= { bwaVLIpParams 6 }
|
|
|
|
bwaVLRunTimeSubNetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The run-time Subnet Mask. If DHCP is used the Run Time
|
|
Subnet Mask is the mask given to the unit by the server.
|
|
Otherwise it is the manually configured mask."
|
|
::= { bwaVLIpParams 7 }
|
|
|
|
bwaVLRunTimeDefaultIPGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The run-time Gateway IP address. If DHCP is used the
|
|
Run Time Gateway IP Address is the address given to the
|
|
unit by the server. Otherwise it is the manually
|
|
configured address."
|
|
::= { bwaVLIpParams 8 }
|
|
|
|
|
|
-- Bridge Params
|
|
-- ==============
|
|
bwaVLBridgeParameters OBJECT IDENTIFIER ::= {bwaVLMib 5}
|
|
|
|
|
|
bwaVLVLANSupport OBJECT IDENTIFIER ::= {bwaVLBridgeParameters 1}
|
|
|
|
bwaVLVlanID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
VLAN ID for data frame tagging.
|
|
Applicable to Access Link only.
|
|
Range: 1 to 4094. 0 - not applicable."
|
|
::= { bwaVLVLANSupport 1 }
|
|
|
|
bwaVLEthernetLinkType OBJECT-TYPE
|
|
SYNTAX INTEGER { accessLink (1),
|
|
trunkLink (2),
|
|
hybridLink (3),
|
|
serviceProviderLink (4) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
VLAN support mode (Link Type).
|
|
The Access Link option is not available for AU/BU.
|
|
Service Provider Link is not available for BU/RB."
|
|
::= { bwaVLVLANSupport 2 }
|
|
|
|
bwaVLManagementVlanID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
VLAN ID for management frame tagging.
|
|
Range: 1 to 4094, 65535 for No VLAN tagging."
|
|
::= { bwaVLVLANSupport 3 }
|
|
|
|
bwaVLVLANForwarding OBJECT IDENTIFIER ::= {bwaVLVLANSupport 4}
|
|
|
|
bwaVLVlanForwardingSupport OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1) , enable (2), na(255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Enables or disables the VLAN forwarding feature.
|
|
(applicable in Trunk and Service Provider links only)."
|
|
::= { bwaVLVLANForwarding 1 }
|
|
|
|
bwaVLVlanForwardingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLVlanForwardingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
A VLAN Forwarding Table of up to 20 VLAN IDs of devices
|
|
to which data frames are forwarded when VLAN Forwarding
|
|
is Enabled. (applicable in Trunk and Service Provider links only)."
|
|
::= { bwaVLVLANForwarding 2 }
|
|
|
|
bwaVLVlanForwardingEntry OBJECT-TYPE
|
|
SYNTAX BwaVLVlanForwardingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
A VLAN Forwarding Table entry. (applicable in Trunk and Service Provider
|
|
links only)."
|
|
INDEX { bwaVLVlanForwardingTableIdx }
|
|
::= { bwaVLVlanForwardingTable 1 }
|
|
|
|
BwaVLVlanForwardingEntry ::= SEQUENCE {
|
|
bwaVLVlanForwardingTableIdx INTEGER,
|
|
bwaVLVlanIdForwarding INTEGER
|
|
}
|
|
|
|
|
|
bwaVLVlanForwardingTableIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..20)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
A read only table index for a VLAN entry in the VLAN
|
|
Forwarding Table."
|
|
::= { bwaVLVlanForwardingEntry 1 }
|
|
|
|
bwaVLVlanIdForwarding OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The list of VLAN ID's in the VLAN ID Forwarding Table.
|
|
To Remove a VLAN ID - SET the corresponding entry to 0.
|
|
To Add a new VLAN ID SET an entry which is currently 0.
|
|
Range : 0 to 4094"
|
|
::= { bwaVLVlanForwardingEntry 2 }
|
|
|
|
bwaVLVlanRelaying OBJECT IDENTIFIER ::= {bwaVLVLANSupport 5}
|
|
|
|
bwaVLVlanRelayingSupport OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1) , enable (2), na(255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP products.
|
|
Enables or disables VLAN Relaying (applicable in
|
|
Trunk and Service Provider links only)."
|
|
::= { bwaVLVlanRelaying 1 }
|
|
|
|
bwaVLVlanRelayingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLVlanRelayingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP products.
|
|
A VLAN Relaying Table of up to 20 VLAN IDs of devices
|
|
to which data frames are relayed when VLAN Relaying is
|
|
Enabled. (applicable in Trunk and Service Provider links only)."
|
|
::= { bwaVLVlanRelaying 2 }
|
|
|
|
bwaVLVlanRelayingEntry OBJECT-TYPE
|
|
SYNTAX BwaVLVlanRelayingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP products.
|
|
A VLAN Relaying Table entry. (applicable in Trunk and Service
|
|
Provider links only)."
|
|
INDEX { bwaVLVlanRelayingTableIdx }
|
|
::= { bwaVLVlanRelayingTable 1 }
|
|
|
|
BwaVLVlanRelayingEntry ::= SEQUENCE {
|
|
bwaVLVlanRelayingTableIdx INTEGER,
|
|
bwaVLVlanIdRelaying INTEGER
|
|
}
|
|
|
|
bwaVLVlanRelayingTableIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..20)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP products.
|
|
A table index for a VLAN entry in the VLAN
|
|
Relaying Table."
|
|
::= { bwaVLVlanRelayingEntry 1 }
|
|
|
|
|
|
bwaVLVlanIdRelaying OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP products.
|
|
The list of VLAN ID's in the VLAN ID Relaying Table.
|
|
To Remove a VLAN ID - SET the corresponding entry to 0.
|
|
To Add a new VLAN ID SET an entry which is currently 0.
|
|
Range: 0 to 4094 , 0 - remove entry."
|
|
::= { bwaVLVlanRelayingEntry 2 }
|
|
|
|
|
|
bwaVLVLANTrafficPriority OBJECT IDENTIFIER ::= {bwaVLVLANSupport 6}
|
|
|
|
bwaVLVlanDataPriority OBJECT-TYPE
|
|
SYNTAX INTEGER { na(255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Priority tagging for data frames. Applicable to Access
|
|
Link only.
|
|
Range: 0 to 7."
|
|
::= { bwaVLVLANTrafficPriority 1 }
|
|
|
|
bwaVLVlanManagementPriority OBJECT-TYPE
|
|
SYNTAX INTEGER { na(255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Priority tagging for management frames. Applicable to
|
|
Access Link and Trunk Link only.
|
|
Range: 0 to 7."
|
|
::= { bwaVLVLANTrafficPriority 2 }
|
|
|
|
|
|
bwaVLVlanPriorityThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER { na(255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. Not applicable to units with SW
|
|
version 3.1 or higher.
|
|
Priority threshold for tagged frames received from
|
|
Ethernet port. Applicable to Hybrid Link and Trunk Link
|
|
only.
|
|
Valid values: 0-7."
|
|
::= { bwaVLVLANTrafficPriority 3 }
|
|
|
|
bwaVLVLANQinQ OBJECT IDENTIFIER ::= {bwaVLVLANSupport 7}
|
|
|
|
bwaVLQinQEthertype OBJECT-TYPE
|
|
SYNTAX INTEGER (33025 .. 36864|37120|37376)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU and SU. Not applicable to PtP units.
|
|
The Ethernet type of the Service Provider Tag.
|
|
The range is 0x8101(33025) - 0x9000(36864), 0x9100(37120), 0x9200(37376)."
|
|
::= { bwaVLVLANQinQ 1 }
|
|
|
|
bwaVLQinQProviderVlanID OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4094)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU only.
|
|
VLAN ID of the Service Provider Tag."
|
|
::= { bwaVLVLANQinQ 2 }
|
|
|
|
bwaVLBridgeAgingTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Bridge aging time for devices on both the Ethernet and
|
|
wireless link sides.
|
|
Range: 20 to 2000 seconds."
|
|
::= { bwaVLBridgeParameters 2 }
|
|
|
|
bwaVLBroadcastRelaying OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1),
|
|
broadcastMulticastEnable (2),
|
|
broadcastEnable (3),
|
|
multicastEnable (4),
|
|
na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP products.
|
|
Enables/disables the relaying of broadcast messages to
|
|
the wireless link."
|
|
::= { bwaVLBridgeParameters 4 }
|
|
|
|
bwaVLUnicastRelaying OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(1), enable(2), na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP products.
|
|
Enables/disables the relaying of unicast messages to
|
|
the wireless link."
|
|
::= { bwaVLBridgeParameters 5 }
|
|
|
|
bwaVLEthBroadcastFiltering OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1),
|
|
onEthernetOnly (2),
|
|
onWirelessOnly (3),
|
|
onBothWirelessAndEthernet (4),
|
|
na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Enables/disables the filtering of Ethernet (layer2)
|
|
broadcasts.
|
|
disable : No filtering.
|
|
onEthernetOnly : Filters broadcasts received on the Ethernet port only.
|
|
onWirelessOnly : Filters broadcasts received on the Wlan port only.
|
|
onBothWirelessAndEth: Filters broadcasts received on both ports."
|
|
::= { bwaVLBridgeParameters 6 }
|
|
|
|
bwaVLEthBroadcastingParameters OBJECT IDENTIFIER ::= {bwaVLBridgeParameters 7}
|
|
|
|
bwaVLDHCPBroadcastOverrideFilter OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1), enable (2), na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Enables or disables the broadcasting of DHCP messages,
|
|
overriding the general *bwaVLEthBroadcastFiltering Ethernet
|
|
broadcast filtering option."
|
|
::= { bwaVLEthBroadcastingParameters 1 }
|
|
|
|
bwaVLPPPoEBroadcastOverrideFilter OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1), enable (2), na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Enables or disables the broadcasting of PPPoE messages,
|
|
overriding the general *bwaVLEthBroadcastFiltering Ethernet
|
|
broadcast filtering option."
|
|
::= { bwaVLEthBroadcastingParameters 2 }
|
|
|
|
bwaVLARPBroadcastOverrideFilter OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1), enable (2), na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Enables or disables the broadcasting of ARP messages,
|
|
overriding the general *bwaVLEthBroadcastFiltering Ethernet
|
|
broadcast filtering option."
|
|
::= { bwaVLEthBroadcastingParameters 3 }
|
|
|
|
bwaVLEthBroadcastMulticastLimiterOption OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1),
|
|
limitOnlyBroadcasts(2),
|
|
limitMulticastsExceptBroadcasts(3),
|
|
limitAllMulticasts(4) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Enable/disable the limiter for multicast and broadcast packets."
|
|
::= { bwaVLEthBroadcastingParameters 4 }
|
|
|
|
bwaVLEthBroadcastMulticastLimiterThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The limit on the number of multicast and broadcast packets when the
|
|
Ethernet Broadcast/Multicast Limiter Option is enabled.
|
|
Range: 0 to 204800"
|
|
::= { bwaVLEthBroadcastingParameters 5 }
|
|
|
|
bwaVLEthBroadcastMulticastLimiterSendTrapInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The minimum time between two successive traps that are sent indicating the
|
|
number of packets that were dropped by the Ethernet Broadcast/Multicast
|
|
Limiter since the last trap was sent.
|
|
Range: 1 to 60 minutes"
|
|
::= { bwaVLEthBroadcastingParameters 6 }
|
|
|
|
bwaVLToSPriorityParameters OBJECT IDENTIFIER ::= {bwaVLBridgeParameters 8}
|
|
|
|
bwaVLToSPrecedenceThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. Not applicable to units with SW version 3.1 or higher.
|
|
Priority threshold (based on the ToS) for frames received
|
|
from the Ethernet port.
|
|
Range: 0 to 7."
|
|
::= { bwaVLToSPriorityParameters 1 }
|
|
|
|
bwaVLRoamingOption OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1), enable (2), na(255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Disable/enable the roaming feature. When enabled, the SU/RB will start
|
|
scanning for an AU/BU after about one second of not receiving beacons or data
|
|
from current AU/BU. Once it found a new AU/BU, it will also send through
|
|
the wireless network a roaming SNAP on behalf of its clients informing
|
|
other devices in the network of their new location. When disabled, it
|
|
will wait for about seven seconds before starting scanning, and it will not
|
|
send a roaming SNAP."
|
|
::= { bwaVLBridgeParameters 9 }
|
|
|
|
bwaVLMacAddressDenyList OBJECT IDENTIFIER ::= {bwaVLBridgeParameters 10}
|
|
|
|
bwaVLMacAddressDenyListTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLMacAddressDenyListEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP units.
|
|
A list of up to 100 MAC Addresses of SUs.
|
|
If bwaVLMacAddressDenyListAction is set to denyList,
|
|
these are SUs that are not allowed to transfer data
|
|
to the AU.
|
|
If bwaVLMacAddressDenyListAction is set to allowList,
|
|
only these SUs are allowed to transfer data to the AU."
|
|
::= { bwaVLMacAddressDenyList 1 }
|
|
|
|
bwaVLMacAddressDenyListEntry OBJECT-TYPE
|
|
SYNTAX BwaVLMacAddressDenyListEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP units.
|
|
An entry in the Mac Address Deny List Table."
|
|
INDEX { bwaVLMacAddressDenyListTableIdx }
|
|
::= { bwaVLMacAddressDenyListTable 1 }
|
|
|
|
BwaVLMacAddressDenyListEntry ::= SEQUENCE {
|
|
bwaVLMacAddressDenyListTableIdx INTEGER,
|
|
bwaVLMacAddressDenyListId MacAddress
|
|
}
|
|
|
|
bwaVLMacAddressDenyListTableIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP units.
|
|
A read only table index for a MAC Address entry
|
|
in the Mac Address Deny List Table. Range: 1 to 100."
|
|
::= { bwaVLMacAddressDenyListEntry 1 }
|
|
|
|
bwaVLMacAddressDenyListId OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP units.
|
|
The list of MAC Addresses in the Mac Address Deny
|
|
List Table.
|
|
To Remove a MAC Address - SET the corresponding entry
|
|
to 0.
|
|
To Add a new MAC Address - SET an entry which is
|
|
currently 0."
|
|
::= { bwaVLMacAddressDenyListEntry 2 }
|
|
|
|
bwaVLMacAddressDenyListAdd OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP units.
|
|
Add a MAC address to the MAC Address Deny List Table"
|
|
::= { bwaVLMacAddressDenyList 2 }
|
|
|
|
bwaVLMacAddressDenyListRemove OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP units.
|
|
Delete a MAC address from the MAC Address Deny List Table"
|
|
::= { bwaVLMacAddressDenyList 3 }
|
|
|
|
bwaVLNumberOfMacAddressesInDenyList OBJECT-TYPE
|
|
SYNTAX INTEGER { na(255) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP units.
|
|
Number of MAC addresses in the MAC Address Deny List Table."
|
|
::= { bwaVLMacAddressDenyList 4 }
|
|
|
|
bwaVLMacAddressDenyListAction OBJECT-TYPE
|
|
SYNTAX INTEGER { denyList(1), allowedList(2), na(255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Define the action to be used by the Mac Address Deny List.
|
|
allowedList(2) means that the list becomes Allow list."
|
|
::= { bwaVLMacAddressDenyList 5 }
|
|
|
|
|
|
bwaVLPortsControl OBJECT IDENTIFIER ::= {bwaVLBridgeParameters 11}
|
|
|
|
bwaVLEthernetPortControl OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(1), enable(2), na(255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Enable/disable the Ethernet port. When disabled, only
|
|
data frames are blocked. Management frames are accepted."
|
|
::= { bwaVLPortsControl 1 }
|
|
|
|
|
|
-- Air Interface Params
|
|
-- =====================
|
|
bwaVLAirInterface OBJECT IDENTIFIER ::= {bwaVLMib 6}
|
|
|
|
bwaVLESSIDParameters OBJECT IDENTIFIER ::= {bwaVLAirInterface 1}
|
|
|
|
bwaVLESSID OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..31))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The Extended Service Set ID (ESSID) used to prevent
|
|
the merging of collocated systems.
|
|
The ESSID is accessible only with the write community
|
|
string (administrator password).
|
|
Up to 31 printable case sensitive ASCII characters."
|
|
::= { bwaVLESSIDParameters 1 }
|
|
|
|
|
|
bwaVLOperatorESSIDOption OBJECT-TYPE
|
|
SYNTAX INTEGER {disable (1) , enable (2), na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Enabling/disabling the use of the Operator ESSID."
|
|
::= { bwaVLESSIDParameters 2 }
|
|
|
|
|
|
bwaVLOperatorESSID OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..31))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
A secondary ESSID to support easy installation of SUs as well as
|
|
the use of the Best AU/BU feature.
|
|
Accessible only with SNMP Write Community
|
|
Up to 31 printable case sensitive ASCII characters."
|
|
::= { bwaVLESSIDParameters 3}
|
|
|
|
bwaVLRunTimeESSID OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
The ESSID of the associated AU/BU.
|
|
Accessible only with SNMP Write Community.
|
|
Up to 31 printable ASCII characters, case sensitive."
|
|
::= { bwaVLESSIDParameters 4 }
|
|
|
|
|
|
bwaVLMaximumCellRadius OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
For AU/BU: read-write. In units with SW version 2.0 and up -
|
|
applicable only when the Cell Distance Mode is set to Manual.
|
|
The highest distance from the AU/BU of any SU/RB served by it.
|
|
Affects the maximum time the units wait for a response message
|
|
and the slot size by taking into account the round trip propagation delay.
|
|
For SU/RB: read-only. The distance is learned from the AU/BU.
|
|
Range: For units below version 2.0 the range is 0 - 50000 Meters.
|
|
Otherwise - the range is 0 to 54 Kilometers.
|
|
0 means no compensation (minimum slot size, maximal delay timeout)."
|
|
::= { bwaVLAirInterface 2 }
|
|
|
|
bwaVLAIFS OBJECT-TYPE
|
|
SYNTAX INTEGER { oneSlot (1), twoSlots (2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU and SU. Not applicable to BWA-PtP products.
|
|
Not applicable if Wireless Link Prioritization is enabled.
|
|
Arbitration Inter-Frame Spacing (AIFS) value, in slots.
|
|
This is the number of time slots that define the DIFS. (DIFS=SIFS+AIFS).
|
|
A value of 1 should be used only in point-to-point applications to
|
|
allow one unit to have advantage over the other unit."
|
|
::= { bwaVLAirInterface 3 }
|
|
|
|
|
|
bwaVLWirelessTrapThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
A wireless link quality threshold, expressed in % of retransmissions,
|
|
for sending the bwaVLAUWirelessQualityTRAP.
|
|
This trap indicate whether the quality has gone below or
|
|
above the specified threshold.
|
|
The Threshold Range: 1 to 100 (% retransmissions)."
|
|
::= { bwaVLAirInterface 4 }
|
|
|
|
|
|
|
|
bwaVLTransmitPowerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLTransmitPowerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
A table of transmit power parameters. "
|
|
::= { bwaVLAirInterface 5}
|
|
|
|
bwaVLTransmitPowerEntry OBJECT-TYPE
|
|
SYNTAX BwaVLTransmitPowerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
An entry in the Transmit Power Table."
|
|
INDEX { bwaVLTransmitPowerIdx }
|
|
::= { bwaVLTransmitPowerTable 1 }
|
|
|
|
BwaVLTransmitPowerEntry ::= SEQUENCE { bwaVLTransmitPowerIdx INTEGER,
|
|
bwaVLApplicableModulationLevel INTEGER,
|
|
bwaVLMaximumTxPowerRange DisplayString,
|
|
bwaVLTxPower DisplayString,
|
|
bwaVLCurrentTxPower DisplayString
|
|
}
|
|
|
|
bwaVLTransmitPowerIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
An index of an entry in the Transmit Power Table."
|
|
::= { bwaVLTransmitPowerEntry 1 }
|
|
|
|
|
|
bwaVLApplicableModulationLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {level1to5 (1), level6 (2), level7 (3),level8 (4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The applicable modulation level for an entry in the Transmit Power Table.
|
|
Level 8 is not applicable to units with HW revision A."
|
|
::= { bwaVLTransmitPowerEntry 2 }
|
|
|
|
bwaVLMaximumTxPowerRange OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The allowed range for the bwaVLTxPower parameter at the
|
|
applicable modulation level . Range: -10 to the maximum allowed
|
|
power level at the applicable modulation level , in dBm."
|
|
::= { bwaVLTransmitPowerEntry 3 }
|
|
|
|
|
|
bwaVLTxPower OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Read-only for units with SW version 4.0 and higher.
|
|
In AU/BU: The transmit power in dBm defined for the applicable rate.
|
|
In SU/RB: If ATPC is disabled, this is the transmit power in dBm
|
|
defined for the applicable rate.
|
|
If ATPC is enabled, it serves as the initial transmit power in dBm
|
|
for the ATPC algorithm.
|
|
In SU/RB: The range is -10 dBm to the power value defined by
|
|
bwaVLMaximumTxPower for the applicable modulation level.
|
|
In AU/BU: The range is -10 dBm to the power value defined by
|
|
bwaVLMaximumTxPowerRange for the applicable modulation level."
|
|
::= { bwaVLTransmitPowerEntry 4 }
|
|
|
|
|
|
|
|
bwaVLCurrentTxPower OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB.
|
|
The actual transmit power in dBm for the applicable rate.
|
|
Range: -17 to the maximum value defined by bwaVLMaximumTxPowerRange
|
|
for the applicable modulation level."
|
|
::= { bwaVLTransmitPowerEntry 5 }
|
|
|
|
bwaVLMaximumTransmitPowerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLMaximumTransmitPowerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
A table of maximum transmit power parameters. "
|
|
::= { bwaVLAirInterface 6}
|
|
|
|
bwaVLMaximumTransmitPowerEntry OBJECT-TYPE
|
|
SYNTAX BwaVLMaximumTransmitPowerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
An entry in the Maximum Transmit Power Table."
|
|
INDEX { bwaVLMaximumTransmitPowerIdx }
|
|
::= { bwaVLMaximumTransmitPowerTable 1 }
|
|
|
|
BwaVLMaximumTransmitPowerEntry ::= SEQUENCE { bwaVLMaximumTransmitPowerIdx INTEGER,
|
|
bwaVLMaxTxApplicableModulationLevel INTEGER,
|
|
bwaVLDefinedMaximumTxPowerRange DisplayString,
|
|
bwaVLMaxTxPower DisplayString
|
|
}
|
|
|
|
bwaVLMaximumTransmitPowerIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
An index of an entry in the Maximum Transmit Power Table."
|
|
::= { bwaVLMaximumTransmitPowerEntry 1 }
|
|
|
|
|
|
bwaVLMaxTxApplicableModulationLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {level1to5 (1), level6 (2), level7 (3),level8 (4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
The applicable modulation level for an entry in the Maximum
|
|
Transmit Power Table.
|
|
Level 8 is not applicable to units with HW revision A."
|
|
::= { bwaVLMaximumTransmitPowerEntry 2 }
|
|
|
|
bwaVLDefinedMaximumTxPowerRange OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
The allowed range for the bwaVLMaxTxPower parameter at the
|
|
applicable modulation level .
|
|
Range: -10 to the maximum allowed power level at the applicable
|
|
modulation level , in dBm."
|
|
::= { bwaVLMaximumTransmitPowerEntry 3 }
|
|
|
|
|
|
bwaVLMaxTxPower OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Read-only for units with SW version 4.0 and higher.
|
|
The maximum value that can be configured for the bwaVLTxPower
|
|
parameter. This is also the maximum power level that can be reached
|
|
by the ATPC algorithm.
|
|
The range is -10 dBm to the maximum value defined by
|
|
bwaVLDefinedMaximumTxPowerRange for the applicable modulation level."
|
|
::= { bwaVLMaximumTransmitPowerEntry 4 }
|
|
|
|
bwaVLMaxNumOfAssociations OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP products.
|
|
Sets the upper limit for the number of SUs
|
|
that can be associated with the AU.
|
|
Range: For regular AUs (AU-BS, AU-SA)
|
|
the range is from 0 to 512 if encryption is disabled
|
|
the range id form 0 to 124 if encryption is enabled
|
|
For AUS-BS and AUS-SA with SW version 4.0 and higher
|
|
the range is between 0 to 8 or 25 (via licensing).
|
|
For AUS-BS and AUS-SA with SW version below 4.0 the range
|
|
is between 0 to 5.
|
|
BWA-PtP products return 65535."
|
|
::= { bwaVLAirInterface 10 }
|
|
|
|
|
|
bwaVLBestAu OBJECT IDENTIFIER ::= {bwaVLAirInterface 11}
|
|
|
|
bwaVLBestAuSupport OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1), enable (2), na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Disable/enable the Best AU/BU selection mechanism."
|
|
::= { bwaVLBestAu 1 }
|
|
|
|
bwaVLBestAuNoOfScanningAttempts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
The number of scanning attempts to collect information
|
|
for the Best AU/BU decision.
|
|
Range: 1 to 255."
|
|
::= { bwaVLBestAu 2 }
|
|
|
|
bwaVLPreferredAuMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
The MAC address of the preferred AU/BU (overriding the
|
|
Best AU/BU selection process).
|
|
000000000000 means no preferred AU/BU."
|
|
::= { bwaVLBestAu 3 }
|
|
|
|
bwaVLNeighborAuTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLNeighborAuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
A table of data on neighboring AUs/BUs."
|
|
::= { bwaVLBestAu 4}
|
|
|
|
bwaVLNeighborAuEntry OBJECT-TYPE
|
|
SYNTAX BwaVLNeighborAuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
An entry in the Neighbor AU/BU Table."
|
|
INDEX { bwaVLNeighborAuIdx }
|
|
::= { bwaVLNeighborAuTable 1 }
|
|
|
|
BwaVLNeighborAuEntry ::= SEQUENCE { bwaVLNeighborAuIdx INTEGER,
|
|
bwaVLNeighborAuMacAdd MacAddress,
|
|
bwaVLNeighborAuESSID DisplayString,
|
|
bwaVLNeighborAuSNR INTEGER,
|
|
bwaVLNeighborAuAssocLoadStatus INTEGER,
|
|
bwaVLNeighborAuMark INTEGER,
|
|
bwaVLNeighborAuHwRevision INTEGER,
|
|
bwaVLNeighborAuCountryCode INTEGER,
|
|
bwaVLNeighborAuSwVer DisplayString,
|
|
bwaVLNeighborAuAtpcOption INTEGER,
|
|
bwaVLNeighborAuAdapModOption INTEGER,
|
|
bwaVLNeighborAuBurstModeOption INTEGER,
|
|
bwaVLNeighborAuDfsOption INTEGER,
|
|
bwaVLNeighborAuConcatenationOption INTEGER,
|
|
bwaVLNeighborAuLearnCountryCodeBySU INTEGER,
|
|
bwaVLNeighborAuSecurityMode INTEGER,
|
|
bwaVLNeighborAuAuthOption INTEGER,
|
|
bwaVLNeighborAuDataEncyptOption INTEGER,
|
|
bwaVLNeighborAuPerSuDistanceLearning INTEGER
|
|
}
|
|
|
|
bwaVLNeighborAuIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..20)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
An index of an entry in the Neighbor AU/BU Table."
|
|
::= { bwaVLNeighborAuEntry 1 }
|
|
|
|
bwaVLNeighborAuMacAdd OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
A MAC address of an AU/BU in the Neighbor AU/BU Table."
|
|
::= { bwaVLNeighborAuEntry 2 }
|
|
|
|
bwaVLNeighborAuESSID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
The ESSID of an AU/BU in the Neighbor AU/BU Table.
|
|
Accessible only with SNMP Write Community."
|
|
::= { bwaVLNeighborAuEntry 3 }
|
|
|
|
bwaVLNeighborAuSNR OBJECT-TYPE
|
|
SYNTAX INTEGER { na (255) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
The received signal quality (SNR) in dB of an AU/BU
|
|
in the Neighbor AU/BU Table."
|
|
::= { bwaVLNeighborAuEntry 4 }
|
|
|
|
bwaVLNeighborAuAssocLoadStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { full (1),notFull (2), na (255) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Neighbor AU/BU association load status in the Neighbor
|
|
AU/BU Table."
|
|
::= { bwaVLNeighborAuEntry 5 }
|
|
|
|
bwaVLNeighborAuMark OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Neighbor AU/BU mark in the Neighbor AU/BU Table."
|
|
::= { bwaVLNeighborAuEntry 6 }
|
|
|
|
bwaVLNeighborAuHwRevision OBJECT-TYPE
|
|
SYNTAX INTEGER {hwRevisionA (1), hwRevisionB (2), hwRevisionC (3),
|
|
hwRevisionD (4), hwRevisionE (5),na (255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Neighbor AU/BU HW revision in the Neighbor AU/BU Table."
|
|
::= { bwaVLNeighborAuEntry 7 }
|
|
|
|
bwaVLNeighborAuCountryCode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Neighbor AU/BU supported country code in the Neighbor
|
|
AU/BU Table."
|
|
::= { bwaVLNeighborAuEntry 8 }
|
|
|
|
bwaVLNeighborAuSwVer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Neighbor AU/BU SW version in the Neighbor
|
|
AU/BU Table."
|
|
::= { bwaVLNeighborAuEntry 9 }
|
|
|
|
bwaVLNeighborAuAtpcOption OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1), enable (2), na (255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Neighbor AU/BU ATPC option configuration in the Neighbor
|
|
AU/BU Table."
|
|
::= { bwaVLNeighborAuEntry 10 }
|
|
|
|
bwaVLNeighborAuAdapModOption OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1), enable (2), na (255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Neighbor AU/BU adaptive modulation option configuration
|
|
in the Neighbor AU/BU Table."
|
|
::= { bwaVLNeighborAuEntry 11 }
|
|
|
|
bwaVLNeighborAuBurstModeOption OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1), enable (2), na (255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Neighbor AU/BU burst mode option configuration
|
|
in the Neighbor AU/BU Table."
|
|
::= { bwaVLNeighborAuEntry 12 }
|
|
|
|
bwaVLNeighborAuDfsOption OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1), enable (2), na(255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Neighbor AU/BU DFS option configuration
|
|
in the Neighbor AU/BU Table."
|
|
::= { bwaVLNeighborAuEntry 14 }
|
|
|
|
bwaVLNeighborAuConcatenationOption OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1), enable (2), na (255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Neighbor AU/BU concatenation option configuration
|
|
in the Neighbor AU/BU Table."
|
|
::= { bwaVLNeighborAuEntry 15 }
|
|
|
|
bwaVLNeighborAuLearnCountryCodeBySU OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1), enable (2), na (255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU only.
|
|
Starting with 4.0 is not applicable for BWA 4900 and BWA PtP products.
|
|
Neighbor AU Learn Country Code by SU configuration
|
|
in the Neighbor AU Table."
|
|
::= { bwaVLNeighborAuEntry 17 }
|
|
|
|
bwaVLNeighborAuSecurityMode OBJECT-TYPE
|
|
SYNTAX INTEGER {wep(1), aesOCB(2), fips197(3), na(255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Neighbor AU/BU security mode configuration
|
|
in the Neighbor AU/BU Table."
|
|
::= { bwaVLNeighborAuEntry 18 }
|
|
|
|
bwaVLNeighborAuAuthOption OBJECT-TYPE
|
|
SYNTAX INTEGER {openSystem (1), sharedKey (2), na (255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Neighbor AU/BU authentication option configuration
|
|
in the Neighbor AU/BU Table."
|
|
::= { bwaVLNeighborAuEntry 19 }
|
|
|
|
bwaVLNeighborAuDataEncyptOption OBJECT-TYPE
|
|
SYNTAX INTEGER {disable (1), enable (2), na (255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Neighbor AU/BU data encryption option configuration
|
|
in the Neighbor AU/BU Table."
|
|
::= { bwaVLNeighborAuEntry 20 }
|
|
|
|
bwaVLNeighborAuPerSuDistanceLearning OBJECT-TYPE
|
|
SYNTAX INTEGER {disable (1), enable (2), na (255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU only.
|
|
Neighbor AU per SU distance learning option configuration
|
|
in the Neighbor AU Table."
|
|
::= { bwaVLNeighborAuEntry 21 }
|
|
|
|
bwaVLFrequencyDefinition OBJECT IDENTIFIER ::= {bwaVLAirInterface 12}
|
|
|
|
|
|
bwaVLSubBandLowerFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Applicable to SU only.
|
|
Not applicable to units with SW version 2.0 or higher.
|
|
The lowest frequency in the subset to be used for scanning.
|
|
For 5.8GHz products the range is 5740 to 5830 MHz using 10MHz resolution.
|
|
For 4.9GHz products the range is 4920 to 5080 MHz using 10MHz resolution.
|
|
For HW Revision C and above this leaf is not relevant - shall return 0."
|
|
::= { bwaVLFrequencyDefinition 1 }
|
|
|
|
bwaVLSubBandUpperFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Applicable to SU only.
|
|
Not applicable to units with SW version 2.0 or higher.
|
|
The highest frequency in the subset to be used for scanning.
|
|
For 5.8GHz products the range is 5740 to 5830 MHz using 10MHz resolution.
|
|
For 4.9GHz products the range is 4920 to 5080 MHz using 10MHz resolution.
|
|
For HW Revision C and above this leaf is not relevant - shall return 0."
|
|
::= { bwaVLFrequencyDefinition 2 }
|
|
|
|
bwaVLScanningStep OBJECT-TYPE
|
|
SYNTAX INTEGER { mhz-5(1), mhz-10(2) , mhz-20(3), na(255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units - For flexible Sub-Bands only.
|
|
For units with version 2.0 and above this is a read-only parameter.
|
|
The scanning step to be used for generating the frequency subset."
|
|
::= { bwaVLFrequencyDefinition 3 }
|
|
|
|
|
|
bwaVLFrequencySubsetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLFrequencySubsetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB and to AU/BU.
|
|
Not applicable to SU/RB with SW version 4.0 and higher.
|
|
The Frequency Subset Table that includes all frequencies from
|
|
the selected Sub-band."
|
|
::= { bwaVLFrequencyDefinition 4 }
|
|
|
|
bwaVLFrequencySubsetEntry OBJECT-TYPE
|
|
SYNTAX BwaVLFrequencySubsetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB and to AU/BU.
|
|
Not applicable to SU/RB with SW version 4.0 and higher.
|
|
An entry in the Frequency Subset Table. "
|
|
INDEX { bwaVLFrequencySubsetTableIdx }
|
|
::= { bwaVLFrequencySubsetTable 1 }
|
|
|
|
BwaVLFrequencySubsetEntry ::= SEQUENCE {
|
|
bwaVLFrequencySubsetTableIdx INTEGER,
|
|
bwaVLFrequencySubsetFrequency INTEGER,
|
|
bwaVLFrequencySubsetActive INTEGER,
|
|
bwaVLFrequencySubsetFrequencyNew DisplayString
|
|
}
|
|
|
|
bwaVLFrequencySubsetTableIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..40)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB and to AU/BU.
|
|
Not applicable to SU/RB with SW version 4.0 and higher.
|
|
An index of an entry in the Frequency subset Table."
|
|
::= { bwaVLFrequencySubsetEntry 1 }
|
|
|
|
|
|
bwaVLFrequencySubsetFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB and to AU/BU.
|
|
Not applicable to SU/RB with SW version 4.0 and higher.
|
|
Applicable to all units with HW revision B and lower
|
|
(for units with HW revision C and higher replaced by
|
|
bwaVLFrequencySubsetFrequencyNew to support a
|
|
resolution of 0.5 MHz).
|
|
The frequency in MHz of an entry in the Frequency Subset table."
|
|
::= { bwaVLFrequencySubsetEntry 2 }
|
|
|
|
bwaVLFrequencySubsetActive OBJECT-TYPE
|
|
SYNTAX INTEGER {active (1) , notActive (2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB and to AU/BU.
|
|
Not applicable to SU/RB with SW version 4.0 and higher.
|
|
The status of an entry in the Frequency subset Table.
|
|
The frequency of an active entry will be included in the
|
|
final list of frequencies to be used for scanning."
|
|
::= { bwaVLFrequencySubsetEntry 3 }
|
|
|
|
bwaVLFrequencySubsetFrequencyNew OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Not applicable to SU/RB with SW version 4.0 and higher.
|
|
The frequency in MHz of an entry in the Frequency Subset table.
|
|
(Replaces bwaVLFrequencySubsetFrequency to support a resolution
|
|
of 0.5 MHz for units with HW revision C and higher)."
|
|
::= { bwaVLFrequencySubsetEntry 4 }
|
|
|
|
bwaVLSetSelectedFreqSubset OBJECT-TYPE
|
|
SYNTAX INTEGER {setSelectedFreqsSubset(1) ,cancel (2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB and to AU/BU.
|
|
Not applicable to SU/RB with SW version 4.0 and higher.
|
|
Apply the selected subset.
|
|
After the next reset the new subset will be used."
|
|
::= { bwaVLFrequencyDefinition 5 }
|
|
|
|
|
|
|
|
|
|
bwaVLCurrentFrequencySubsetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLCurrentFrequencySubsetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB and to AU/BU.
|
|
Not applicable to SU/RB with SW version 4.0 and higher.
|
|
The Current Frequency Subset table. In SU/RB it includes all
|
|
frequencies that are currently used for scanning.
|
|
In AU/BU it includes all frequencies that can be used by the
|
|
DFS mechanism (if applicable)"
|
|
::= { bwaVLFrequencyDefinition 6 }
|
|
|
|
bwaVLCurrentFrequencySubsetEntry OBJECT-TYPE
|
|
SYNTAX BwaVLCurrentFrequencySubsetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB and to AU/BU.
|
|
An entry in the Current Frequency Subset Table. "
|
|
INDEX { bwaVLCurrentFrequencySubsetTableIdx }
|
|
::= { bwaVLCurrentFrequencySubsetTable 1 }
|
|
|
|
BwaVLCurrentFrequencySubsetEntry ::= SEQUENCE {
|
|
bwaVLCurrentFrequencySubsetTableIdx INTEGER,
|
|
bwaVLCurrentFrequencySubsetFrequency INTEGER,
|
|
bwaVLCurrentFrequencySubsetFrequencyNew DisplayString
|
|
}
|
|
|
|
bwaVLCurrentFrequencySubsetTableIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..40)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB and to AU/BU.
|
|
An index of an entry in the Current Frequency subset Table.
|
|
Not applicable to SU/RB with SW version 4.0 and higher."
|
|
::= { bwaVLCurrentFrequencySubsetEntry 1 }
|
|
|
|
|
|
bwaVLCurrentFrequencySubsetFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Not applicable to SU/RB with SW version 4.0 and higher.
|
|
Applicable to all units with HW revision B and lower
|
|
(for units with HW revision C and higher replaced by
|
|
bwaVLCurrentFrequencySubsetFrequencyNew to support
|
|
a resolution of 0.5 MHz).
|
|
The frequency in MHz of an entry in the Current Frequency Subset table."
|
|
::= { bwaVLCurrentFrequencySubsetEntry 2 }
|
|
|
|
bwaVLCurrentFrequencySubsetFrequencyNew OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. Not applicable to SU/RB with SW version 4.0 and higher.
|
|
The frequency in MHz of an entry in the Current Frequency Subset table.
|
|
(Replaces bwaVLCurrentFrequencySubsetFrequency to support a
|
|
resolution of 0.5 MHz for units with HW revision C and higher)."
|
|
::= { bwaVLCurrentFrequencySubsetEntry 3 }
|
|
|
|
bwaVLCurrentAUOperatingFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU with HW revision B and lower
|
|
(for units with HW revision C and higher replaced by
|
|
bwaVLCurrentUOperatingFrequencyNew to support a resolution
|
|
of 0.5 MHz).
|
|
The operating frequency in MHz.
|
|
For 5.8GHz products with SW version below 2.0 the range is
|
|
5740 to 5830 MHz using 10MHz resolution.
|
|
For units with SW version 2.0 and up the range is as defined
|
|
in the selected Sub Band."
|
|
::= { bwaVLFrequencyDefinition 7 }
|
|
|
|
bwaVLCurrentAUOperatingFrequencyNew OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU. The operating frequency in MHz.
|
|
(Replaces bwaVLCurrentAUOperatingFrequency to support
|
|
a resolution of 0.5 MHz for units with HW revision C and higher).
|
|
For 5.8GHz products with SW version below 2.0 the range is
|
|
5740 to 5830 MHz using 10MHz resolution.
|
|
For units with SW version 2.0 and up the range is as defined
|
|
in the selected Sub Band."
|
|
::= { bwaVLFrequencyDefinition 13 }
|
|
|
|
bwaVLAUDefinedFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU with HW revision B and lower
|
|
(for units with HW revision C and higher replaced by
|
|
bwaVLAUDefinedFrequencyNew to support a resolution of 0.5 MHz).
|
|
For 5.8GHz products with SW version below 2.0 this is the frequency
|
|
in MHz of the AU/BU after the next reset.
|
|
For units with SW version 2.0 and up this is the frequency in MHz
|
|
to use when the DFS Option is disabled.
|
|
For 5.8GHz products with SW version below 2.0 the range is
|
|
5740 to 5830 MHz using 10MHz resolution.
|
|
For units with SW version 2.0 and up the range is as defined
|
|
in the selected Sub Band."
|
|
::= { bwaVLFrequencyDefinition 8 }
|
|
|
|
bwaVLAUDefinedFrequencyNew OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU.
|
|
For 5.8GHz products with SW version below 2.0 this is the
|
|
frequency in MHz of the AU/BU after the next reset.
|
|
For units with SW version 2.0 and up this is the
|
|
frequency in MHz to use when the DFS Option is disabled.
|
|
(Replaces bwaVLAUDefinedFrequency to support a resolution
|
|
of 0.5 MHz for units with HW revision C and higher).
|
|
For 5.8GHz products with SW version below 2.0 the range
|
|
is 5740 to 5830 MHz using 10MHz resolution.
|
|
For units with SW version 2.0 and up the range is as
|
|
defined in the selected Sub Band."
|
|
::= { bwaVLFrequencyDefinition 14 }
|
|
|
|
bwaVLCurrentSUOperatingFrequency OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
The frequency used currently by the unit.
|
|
For 5.8GHz products with SW version below 2.0 the range is
|
|
5740 to 5830 MHz using 10MHz resolution.
|
|
For units with SW version 2.0 and up the range is as defined
|
|
in the selected Sub Band."
|
|
::= { bwaVLFrequencyDefinition 9 }
|
|
|
|
bwaVLSubBandSelect OBJECT IDENTIFIER ::= {bwaVLFrequencyDefinition 10}
|
|
|
|
|
|
bwaVLSelectSubBandIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units with SW version below 4.0
|
|
For units with SW version 4.0 and up it is applicable
|
|
only for AU/BU. For SU/RB it defines only the sub-band
|
|
for the Spectrum Analyzer.
|
|
The ID of the sub-band used by the unit."
|
|
::= { bwaVLSubBandSelect 1 }
|
|
|
|
|
|
|
|
bwaVLDFSParameters OBJECT IDENTIFIER ::= {bwaVLFrequencyDefinition 11}
|
|
|
|
bwaVLDFSOption OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1) , enable (2), na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Enabling/disabling the DFS Algorithm.
|
|
Not applicable if DFS Option is not supported by the current Sub Band."
|
|
::= { bwaVLDFSParameters 1 }
|
|
|
|
bwaVLDFSChannelCheckTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Defines the time the unit checks the channel for presence of
|
|
radar signals and does not transmit after power up or association
|
|
or after moving to a new channel due to detecting radar in the used
|
|
channel. Range: 1 to 3600 (seconds)."
|
|
::= { bwaVLDFSParameters 3 }
|
|
|
|
|
|
bwaVLDFSChannelAvoidancePeriod OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Defines the time after detecting radar signals in a channel of
|
|
avoiding using the channel or adjacent channels in
|
|
accordance with the bandwidth. Range: 1 to 60 (minutes)."
|
|
::= { bwaVLDFSParameters 4 }
|
|
|
|
|
|
bwaVLDFSSuWaitingOption OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1) , enable (2), na(255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Defines whether the associated SUs should wait for this AU/BU
|
|
after it stopped transmitting due to radar detection, before
|
|
they starts scanning for other AUs/BUs."
|
|
::= { bwaVLDFSParameters 5 }
|
|
|
|
|
|
bwaVLDFSClearRadarDetectedChannelsAfterReset OBJECT-TYPE
|
|
SYNTAX INTEGER { cancel (1), clearRadarChannels (2), na(255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Clear Radar Detected and Adjacent to Radar channels after unit reset.
|
|
Returns the unit to operate in default frequency."
|
|
::= { bwaVLDFSParameters 6 }
|
|
|
|
bwaVLDFSRadarDetectionChannelsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLDFSRadarDetectionChannelsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Applicable only when DFS option is on.
|
|
Displays the current channels defined in the sub-band and their radar
|
|
detection status."
|
|
::= { bwaVLDFSParameters 7 }
|
|
|
|
bwaVLDFSRadarDetectionChannelsEntry OBJECT-TYPE
|
|
SYNTAX BwaVLDFSRadarDetectionChannelsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
An entry in the bwaVLDFSRadarDetectionChannelsTable."
|
|
INDEX { bwaVLDFSChannelIdx }
|
|
::= { bwaVLDFSRadarDetectionChannelsTable 1 }
|
|
|
|
BwaVLDFSRadarDetectionChannelsEntry ::= SEQUENCE {
|
|
bwaVLDFSChannelIdx INTEGER,
|
|
bwaVLDFSChannelFrequency INTEGER,
|
|
bwaVLDFSChannelRadarStatus INTEGER,
|
|
bwaVLDFSChannelFrequencyNew DisplayString }
|
|
|
|
bwaVLDFSChannelIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..40)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only. Read-only.
|
|
The index of the entry in the
|
|
bwaVLDFSRadarDetectionChannelsTable."
|
|
::= { bwaVLDFSRadarDetectionChannelsEntry 1 }
|
|
|
|
bwaVLDFSChannelFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU with HW revision B and lower
|
|
(for units with HW revision C and higher replaced by
|
|
bwaVLDFSChannelFrequency New to support a resolution
|
|
of 0.5 MHz).
|
|
The frequency in MHz of a channel in the DFS Radar
|
|
Detection Channels Table."
|
|
::= { bwaVLDFSRadarDetectionChannelsEntry 2 }
|
|
|
|
bwaVLDFSChannelRadarStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { radarFree (1),
|
|
adjacentToRadar (2),
|
|
radarDetected (3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The radar detection status of a channel in
|
|
bwaVLDFSRadarDetectionChannelTable."
|
|
::= { bwaVLDFSRadarDetectionChannelsEntry 3 }
|
|
|
|
bwaVLDFSChannelFrequencyNew OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU. The frequency of a channel in the
|
|
DFS Radar Detection Channels Table.
|
|
(Replaces bwaVLDFSChannelFrequency to support a
|
|
resolution of 0.5 MHz for units with HW revision C and higher)."
|
|
::= { bwaVLDFSRadarDetectionChannelsEntry 4 }
|
|
|
|
bwaVLDFSMinimumPulsesToDetect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Defines the minimum number of pulses to detect a radar.
|
|
Range: 1 - 100."
|
|
::= { bwaVLDFSParameters 8 }
|
|
|
|
|
|
bwaVLDFSChannelReuseParameters OBJECT IDENTIFIER ::= {bwaVLDFSParameters 9}
|
|
|
|
bwaVLDFSChannelReuseOption OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1) , enable (2), na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Enabling/disabling the DFS Channel Reuse Algorithm.
|
|
Not applicable if DFS Option is not supported by the current Sub Band."
|
|
::= { bwaVLDFSChannelReuseParameters 1 }
|
|
|
|
bwaVLDFSRadarActivityAssessmentPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Range: 1 to 12 (Houres)."
|
|
::= { bwaVLDFSChannelReuseParameters 2 }
|
|
|
|
bwaVLDFSMaximumNumberOfDetectionsInAssessmentPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Range: 1 to 10 (Times)."
|
|
::= { bwaVLDFSChannelReuseParameters 3 }
|
|
|
|
bwaVLCountryCodeLearningBySU OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(1), enable(2), na(255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Starting with 4.0 it is nor applicable for BWA 4900 and BWA PtP.
|
|
Defines whether the SUs learn the country code of the AU."
|
|
::= { bwaVLFrequencyDefinition 12 }
|
|
|
|
|
|
-- AUTOMATIC SUB BAND SELECT BEGIN
|
|
|
|
bwaVLAutoSubBandSelect OBJECT IDENTIFIER ::= { bwaVLFrequencyDefinition 15 }
|
|
|
|
bwaVLAutoSubBandSelectedFreqSubset OBJECT-TYPE
|
|
SYNTAX INTEGER { setAllSelectedFreqsSubset(1), cancel (2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB with SW version 4.0 and higher.
|
|
Apply the selected subset. After the next reset the new
|
|
subset will be used for scanning."
|
|
::= { bwaVLAutoSubBandSelect 1 }
|
|
|
|
bwaVLAutoSubBandFrequencySubsetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLAutoSubBandFrequencySubsetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB with SW version 4.0 and higher.
|
|
The Frequency Subset Table that includes all available
|
|
sub-bands and all the frequencies in these sub-bands."
|
|
::= { bwaVLAutoSubBandSelect 2 }
|
|
|
|
bwaVLAutoSubBandFrequencySubsetEntry OBJECT-TYPE
|
|
SYNTAX BwaVLAutoSubBandFrequencySubsetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB with SW version 4.0 and higher.
|
|
An entry in the Frequency Subset Table. "
|
|
INDEX { bwaVLAutoSubBandFrequencySubsetBandIdx, bwaVLAutoSubBandFrequencySubsetFrequencyIdx }
|
|
::= { bwaVLAutoSubBandFrequencySubsetTable 1 }
|
|
|
|
BwaVLAutoSubBandFrequencySubsetEntry ::= SEQUENCE {
|
|
bwaVLAutoSubBandFrequencySubsetBandIdx INTEGER,
|
|
bwaVLAutoSubBandFrequencySubsetFrequencyIdx INTEGER,
|
|
bwaVLAutoSubBandFrequencySubsetActive INTEGER,
|
|
bwaVLAutoSubBandFrequencySubsetFrequency DisplayString
|
|
}
|
|
|
|
bwaVLAutoSubBandFrequencySubsetBandIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..5)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB with SW version 4.0 and higher.
|
|
The index of the applicable Sub Band.
|
|
This is the Sub Band ID of the relevant entry in
|
|
the Country Dependent Parameters table.
|
|
Serves also as an index of the entry in the
|
|
Frequency subset Table."
|
|
::= { bwaVLAutoSubBandFrequencySubsetEntry 1 }
|
|
|
|
bwaVLAutoSubBandFrequencySubsetFrequencyIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..40)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB with SW version 4.0 and higher.
|
|
The index of the applicable frequency in the
|
|
applicable Sub Band.
|
|
Serves also as an index of the entry in the
|
|
Frequency subset Table."
|
|
::= { bwaVLAutoSubBandFrequencySubsetEntry 2 }
|
|
|
|
|
|
bwaVLAutoSubBandFrequencySubsetActive OBJECT-TYPE
|
|
SYNTAX INTEGER {active (1) , notActive (2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB with SW version 4.0 and higher.
|
|
The status of an entry in the Auto Sub Band Frequency subset Table.
|
|
The frequency of an active entry will be included in the
|
|
final list of frequencies to be used for scanning."
|
|
::= { bwaVLAutoSubBandFrequencySubsetEntry 3 }
|
|
|
|
bwaVLAutoSubBandFrequencySubsetFrequency OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB with SW version 4.0 and higher.
|
|
The frequency in MHz of the entry in the Auto Sub Band Frequency Subset table."
|
|
::= { bwaVLAutoSubBandFrequencySubsetEntry 4 }
|
|
|
|
|
|
-- AUTOMATIC SUB BAND SELECT END
|
|
|
|
|
|
bwaVLATPC OBJECT IDENTIFIER ::= {bwaVLAirInterface 13}
|
|
|
|
bwaVLAtpcOption OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1) , enable (2) , na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable all units.
|
|
Enabling/disabling the ATPC Algorithm."
|
|
::= { bwaVLATPC 1 }
|
|
|
|
bwaVLDeltaFromMinSNRLevel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable AU/BU only.
|
|
The Minimum SNR Level plus the value of this parameter define the
|
|
maximum desired level of the average SNR at the AU/BU.
|
|
If the ATPC Option is enabled, than if the received SNR is above
|
|
the maximum desired level, the AU/BU will transmit Power-Down
|
|
messages to the applicable SU/RB.
|
|
Range: 4 to 20 (dB)."
|
|
::= { bwaVLATPC 2 }
|
|
|
|
bwaVLMinimumSNRLevel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable AU/BU only.
|
|
Defines the minimum desired level of the average SNR at the AU/BU.
|
|
Below this level, if *AtpcOption is enabled, the AU/BU will transmit
|
|
ATPC Power-Up messages to the applicable SU/RB.
|
|
The *MinimumSNRLevel cannot be higher than *MaximumSNRLevel.
|
|
Range: 4 to 60 (dB)."
|
|
::= { bwaVLATPC 3 }
|
|
|
|
|
|
bwaVLMinimumIntervalBetweenATPCMessages OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable AU/BU only.
|
|
The minimum interval between two consecutive AU/BU to SU/RB messages.
|
|
Range: 1 to 3600 (Sec)."
|
|
::= { bwaVLATPC 4 }
|
|
|
|
|
|
|
|
bwaVLPowerLevelSteps OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable AU/BU only.
|
|
The step in dB that the SU/RB will use when receiving an ATPC
|
|
Power-Up/Power-Down message.
|
|
Range: 1 to 20 (dB)."
|
|
::= { bwaVLATPC 6 }
|
|
|
|
bwaVLCellDistanceParameters OBJECT IDENTIFIER ::= {bwaVLAirInterface 15}
|
|
|
|
bwaVLCellDistanceMode OBJECT-TYPE
|
|
SYNTAX INTEGER { automatic (1) , manual (2), na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable AU/BU only.
|
|
The selected mode of deciding on Cell Distance."
|
|
::= { bwaVLCellDistanceParameters 1 }
|
|
|
|
bwaVLFairnessFactor OBJECT-TYPE
|
|
SYNTAX INTEGER { na (255)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable AU/BU only.
|
|
Not applicable to BWA-PtP products for SW version below 4.0..
|
|
The percentage of the maximum distance that is taken into
|
|
account in the time slot calculation. Range: 0 to 100
|
|
(Percent). A value of 0 means the minimal slot size
|
|
(9 microseconds).
|
|
BWA-PtP products with SW version below 4.0 return na."
|
|
::= { bwaVLCellDistanceParameters 2 }
|
|
|
|
bwaVLMeasuredCellDistance OBJECT-TYPE
|
|
SYNTAX INTEGER {below-2-Km(1)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable AU/BU only.
|
|
The Maximum Cell Distance as calculated by the AU/BU.
|
|
Range: 0 to 54 (Kilometers)."
|
|
::= { bwaVLCellDistanceParameters 3 }
|
|
|
|
bwaVLUnitWithMaxDistance OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable AU only.
|
|
Not applicable to BWA-PtP units.
|
|
The MAC address of the unit with the maximum distance
|
|
from the AU."
|
|
::= { bwaVLCellDistanceParameters 4 }
|
|
|
|
bwaVLPerSuDistanceLearning OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1) , enable (2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Aplicable to AU only. Applicable only if Cell Distance Mode is
|
|
set to Automatic. When disabled, all SUs in the cell will use
|
|
for the ACK Timeout the computed distance of the farthest SU.
|
|
When enabled, each SU will use its own computed distance"
|
|
::= { bwaVLCellDistanceParameters 5 }
|
|
|
|
bwaVLScanningMode OBJECT-TYPE
|
|
SYNTAX INTEGER { passive (1), active (2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
The scanning mode. In cells where the DFS Option is enabled
|
|
Scanning Mode is forced to Passive."
|
|
::= { bwaVLAirInterface 16 }
|
|
|
|
bwaVLAntennaGain OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. Read-write in units where
|
|
bwaVLAntennaGainChange is supported.
|
|
Read-only in units where bwaVLAntennaGainChange is not supported.
|
|
The net gain (including cable attenuation for detached antennas) of
|
|
the antenna.
|
|
Range: 0 - to Maximum EIRP defined by country code + 10 (dBi).
|
|
A value of -2 (this value is configurable only in factory)
|
|
means don't care.
|
|
A value of -1 (this value is configurable only in factory)
|
|
means that the unit will not transmit until the actual value
|
|
is configured."
|
|
::= { bwaVLAirInterface 17 }
|
|
|
|
bwaVLSpectrumAnalysisParameters OBJECT IDENTIFIER ::= {bwaVLAirInterface 18}
|
|
|
|
bwaVLSpectrumAnalysisChannelScanPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The period of staying on each channel for information gathering
|
|
when performing Spectrum analysis.
|
|
Range: 2-30 seconds."
|
|
::= { bwaVLSpectrumAnalysisParameters 1 }
|
|
|
|
bwaVLSpectrumAnalysisScanCycles OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The number of scanning cycles when performing Spectrum Analysis.
|
|
Range: 1-100."
|
|
::= { bwaVLSpectrumAnalysisParameters 2 }
|
|
|
|
bwaVLAutomaticChannelSelection OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1), enable (2), na (255)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Defines weather the AU/BU shall choose the most noise free channel
|
|
upon startup after spectrum analysis."
|
|
::= { bwaVLSpectrumAnalysisParameters 3 }
|
|
|
|
bwaVLSpectrumAnalysisActivation OBJECT-TYPE
|
|
SYNTAX INTEGER { cancelOperation (1), activateNow (2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Activates spectrum analysis, the unit is automatically reset upon
|
|
activation."
|
|
::= { bwaVLSpectrumAnalysisParameters 4 }
|
|
|
|
bwaVLSpectrumAnalysisStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { inactive (1), currentlyActive (2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Defines weather the unit is currently under performing
|
|
a spectrum analysis process."
|
|
::= { bwaVLSpectrumAnalysisParameters 5 }
|
|
|
|
bwaVLResetSpectrumCounters OBJECT-TYPE
|
|
SYNTAX INTEGER { cancelOperation (1), resetCounters (2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Resets the spectrum analysis counters."
|
|
::= { bwaVLSpectrumAnalysisParameters 6 }
|
|
|
|
bwaVLSpectrumAnalysisInformationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLSpectrumAnalysisInformationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The spectrum analysis information table."
|
|
::= { bwaVLSpectrumAnalysisParameters 7 }
|
|
|
|
bwaVLSpectrumAnalysisInformationEntry OBJECT-TYPE
|
|
SYNTAX BwaVLSpectrumAnalysisInformationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The spectrum analysis information table entry."
|
|
INDEX { bwaVLSpectrumAnalysisInformationTableIdx }
|
|
::= { bwaVLSpectrumAnalysisInformationTable 1 }
|
|
|
|
BwaVLSpectrumAnalysisInformationEntry ::= SEQUENCE {
|
|
bwaVLSpectrumAnalysisInformationTableIdx INTEGER,
|
|
bwaVLSpectrumAnalysisInformationChannel DisplayString,
|
|
bwaVLSpectrumAnalysisInformationSignalCount INTEGER,
|
|
bwaVLSpectrumAnalysisInformationSignalSNR INTEGER,
|
|
bwaVLSpectrumAnalysisInformationSignalWidth INTEGER,
|
|
bwaVLSpectrumAnalysisInformationOFDMFrames INTEGER
|
|
}
|
|
|
|
|
|
bwaVLSpectrumAnalysisInformationTableIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..60)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
A read only table index for a Spectrum Analysis Information entry in the
|
|
Spectrum Analysis Information Table."
|
|
::= { bwaVLSpectrumAnalysisInformationEntry 1 }
|
|
|
|
bwaVLSpectrumAnalysisInformationChannel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The channels in the Spectrum Analysis Information Table.
|
|
If the unit is currently under spectrum analysis the channels would
|
|
be those on which the analysis is currently performed.
|
|
If the unit is in normal mode the channels would be the those on
|
|
which the last analysis was performed."
|
|
::= { bwaVLSpectrumAnalysisInformationEntry 2 }
|
|
|
|
bwaVLSpectrumAnalysisInformationSignalCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The number of signals (excluding OFDM frames) detected in the channel.
|
|
If the unit is currently under spectrum analysis the count would
|
|
be of the analysis that is currently performed.
|
|
If the unit is in normal mode the count would be of the last
|
|
analysis performed."
|
|
::= { bwaVLSpectrumAnalysisInformationEntry 3 }
|
|
|
|
bwaVLSpectrumAnalysisInformationSignalSNR OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The approximate SNR of the signals (excluding OFDM frames)
|
|
detected in the channel.
|
|
If the unit is currently under spectrum analysis the SNR would
|
|
be of the analysis that is currently performed.
|
|
If the unit is in normal mode the SNR would be of the last
|
|
analysis performed."
|
|
::= { bwaVLSpectrumAnalysisInformationEntry 4 }
|
|
|
|
bwaVLSpectrumAnalysisInformationSignalWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The average width of the signals (excluding OFDM frames)
|
|
detected in the channel.
|
|
If the unit is currently under spectrum analysis the width would
|
|
be of the analysis that is currently performed.
|
|
If the unit is in normal mode the width would be of the last
|
|
analysis performed."
|
|
::= { bwaVLSpectrumAnalysisInformationEntry 5 }
|
|
|
|
bwaVLSpectrumAnalysisInformationOFDMFrames OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The number of OFDM frames detected in the channel.
|
|
If the unit is currently under spectrum analysis the count would
|
|
be of the analysis that is currently performed.
|
|
If the unit is in normal mode the count would be of the last
|
|
analysis performed."
|
|
::= { bwaVLSpectrumAnalysisInformationEntry 6 }
|
|
|
|
bwaVLMaxNumOfAssociationsLimit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP products.
|
|
Shows the limit for the number of SUs that can be associated
|
|
with the AU.
|
|
For AU-BS, AU-SA if Data Encryption is enabled, the upper
|
|
limit is 124, otherwise it is 512.
|
|
For AUS-BS, AUS-SA with SW version 4.0 and higher the upper limit
|
|
is 8 or 25 (via licensing).
|
|
For AUS-BS, AUS-SA with SW version below 4.0 the upper limit is 5.
|
|
BWA-PtP products return 65535."
|
|
::= { bwaVLAirInterface 19 }
|
|
|
|
bwaVLDisassociate OBJECT IDENTIFIER ::= {bwaVLAirInterface 20}
|
|
|
|
bwaVLDisassociateAllSUs OBJECT-TYPE
|
|
SYNTAX INTEGER { cancelOperation (1), disassociateAllSUs(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
The AU shall disassociate all its associated units."
|
|
::= { bwaVLDisassociate 1 }
|
|
|
|
bwaVLDisassociateSuByMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
The AU shall disassociate the SU with the configured MAC address."
|
|
::= { bwaVLDisassociate 2 }
|
|
|
|
bwaVLTxControl OBJECT-TYPE
|
|
SYNTAX INTEGER { on (1), off(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Tx Control of the AU/BU.
|
|
Starting with version 4.0 it is run-time.
|
|
For SW version below 4.0 the unit reset itself.
|
|
If set to ethernetStatusControl, the unit will not transmit
|
|
if the Ethernet link is down.
|
|
This parameter can be configured only via the ethernet port."
|
|
::= { bwaVLAirInterface 21 }
|
|
|
|
bwaVLLostBeaconsWatchdogThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0 | 100..1000 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The number of unsuccessful consecutive transmissions beacons
|
|
before Internal refresh is performed.
|
|
0 means that the lost beacons watchdog is not
|
|
used and internal refresh is not performed."
|
|
::= { bwaVLAirInterface 22}
|
|
|
|
bwaVLTransmitPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units with SW version 4.0 and higher.
|
|
The uniform transmit power for all modulation levels. For a specific
|
|
modulation level the effective transmit power (bwaVLTxPower) is
|
|
the minimum between the uniform transmit power and the maximum
|
|
transmit power for that modulation level."
|
|
::= { bwaVLAirInterface 23 }
|
|
|
|
bwaVLMaximumTxPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to only SU/RB with SW version 4.0 and higher.
|
|
The Maximum Transmit Power for all modulation levels.
|
|
The Maximum Transmit Power for a specific modulation level is the
|
|
minimum between this parameter and the hardware limitation for
|
|
that modulation level"
|
|
::= { bwaVLAirInterface 24 }
|
|
|
|
bwaVLCountryCodeParameters OBJECT IDENTIFIER ::= {bwaVLAirInterface 25}
|
|
|
|
bwaLCountryCodeReApply OBJECT-TYPE
|
|
SYNTAX INTEGER { reapply(1),cancel(2), na(255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Re-apply country code parameters."
|
|
::= { bwaVLCountryCodeParameters 1 }
|
|
|
|
|
|
-- Service Params
|
|
-- ==============
|
|
bwaVLServiceParameters OBJECT IDENTIFIER ::= {bwaVLMib 7}
|
|
|
|
-- bwaVLMirCirOption OBJECT-TYPE
|
|
-- SYNTAX INTEGER {disable (1),
|
|
-- enable (2),
|
|
-- na (255)}
|
|
-- MAX-ACCESS read-write
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "Applicable to AU and SU. Read-only in SU.
|
|
-- The setting in the AU enables/disables the MIR/CIR support
|
|
-- feature for all SUs served by the AU."
|
|
-- ::= { bwaVLServiceParameters 1 }
|
|
|
|
bwaVLMirDownlink OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
The Maximum Information Rate (MIR) from AU/BU to SU/RB.
|
|
MIR must be above bwaVLCirDownlink value.
|
|
Range for set: 128 to 2,048 (Kbps) for SU-3 with SW version below 4.0,
|
|
128 to 3,072 (Kbps) for SU-3 with SW version 4.0 and higher,
|
|
128 to 3,968 (Kbps) for SU-6 with SW version less than 4.0,
|
|
128 to 6,016 (Kbps) for SU-6 with SW version greater than 4.0,
|
|
128 to 14,976 (Kbps) for SU-24,
|
|
128 to 53,888 (Kbps) for SU-BD and SU-54,
|
|
128 to 6,912 (Kbps) for RB-14,
|
|
128 to 22,016 (Kbps) for RB-28,
|
|
128 to 107,904 (Kbps) for RB-100.
|
|
128 to 6,016 (Kbps) for SU-I.
|
|
The actual value (Get) will be the entered value rounded to the nearest
|
|
multiple of 128 (N*128)."
|
|
::= { bwaVLServiceParameters 2 }
|
|
|
|
bwaVLMirUplink OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
The Maximum Information Rate (MIR) from SU/RB to AU/BU.
|
|
MIR must be above bwaVLCirUplink value.
|
|
Range for set: 128 to 2,048 (Kbps) for SU-3,
|
|
128 to 3,968 (Kbps) for SU-6 with SW version less than 4.0,
|
|
128 to 4,096 (Kbps) for SU-6 with SW version greater than 4.0,
|
|
128 to 14,976 (Kbps) for SU-24,
|
|
128 to 53,888 (Kbps) for SU-BD and SU-54,
|
|
128 to 6,912 (Kbps) for RB-14,
|
|
128 to 22,016 (Kbps) for RB-28,
|
|
128 to 107,904 (Kbps) for RB-100.
|
|
128 to 2,048 (Kbps) for SU-I.
|
|
The actual value (Get) will be the entered value rounded to the nearest
|
|
multiple of 128 (N*128)."
|
|
::= { bwaVLServiceParameters 3 }
|
|
|
|
|
|
bwaVLCirDownlink OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU only.
|
|
Not applicable to BWA-PtP products.
|
|
The Committed Information Rate (CIR) from AU to SU.
|
|
CIR must be below bwaVLMirDownlink value.
|
|
Range for Set:
|
|
0 to 2,048 (Kbps) for SU-3 with SW version below 4.0,
|
|
0 to 3,072 (Kbps) for SU-3 with SW version 4.0 and higher,
|
|
0 to 3,968 (Kbps) for SU-6 with SW version less than 4.0,
|
|
0 to 6,016 (Kbps) for SU-6 with SW version greater than 4.0
|
|
0 to 14,976 (Kbps) for SU-24,
|
|
0 to 45,056 (Kbps) for SU-BD and SU-54.
|
|
0 to 6,016 (Kbps) for SU-I.
|
|
The actual value (Get) will be the entered value rounded to the
|
|
nearest multiple of 128 (N*128).
|
|
BWA-PtP products will return 65535."
|
|
::= { bwaVLServiceParameters 4 }
|
|
|
|
|
|
bwaVLCirUplink OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU only.
|
|
Not applicable to BWA-PtP products.
|
|
The Committed Information Rate (CIR) from SU to AU.
|
|
CIR must be below bwaVLMirUplink value.
|
|
Range for Set:
|
|
0 to 2,048 (Kbps) for SU-3,
|
|
0 to 3,968 (Kbps) for SU-6 with SW version less than 4.0,
|
|
0 to 4,096 (Kbps) for SU-6 with SW version greater than 4.0,
|
|
0 to 14,976 (Kbps) for SU-24,
|
|
0 to 45,056 (Kbps) for SU-BD and SU-54.
|
|
0 to 2,048 (Kbps) for SU-I.
|
|
The actual value (Get) will be the entered value rounded to the nearest
|
|
multiple of 128 (N*128).
|
|
BWA-PtP products will return 65535."
|
|
::= { bwaVLServiceParameters 5 }
|
|
|
|
|
|
bwaVLMaxDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU only.
|
|
Not applicable to BWA-PtP products.
|
|
The maximal time packets may be delayed by the
|
|
CIR\MIR mechanism. Above the configured maximal period
|
|
the packets are discarded.
|
|
Range: 300 to 10000 milliseconds.
|
|
BWA-PtP products return 65535."
|
|
::= { bwaVLServiceParameters 6 }
|
|
|
|
bwaVLMaxBurstDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU and SU.
|
|
Not applicable to BWA-PtP products.
|
|
The maximum time during which inactivity bonus time
|
|
can be accumulated for future burst transmissions.
|
|
Range: 0 to 2000 milliseconds.
|
|
BWA-PtP products return 65535"
|
|
::= { bwaVLServiceParameters 7 }
|
|
|
|
bwaVLGracefulDegradationLimit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP products.
|
|
The maximum limit for activating the graceful
|
|
degradation algorithm.
|
|
Range: 0 to 70% rate of the CIR.
|
|
BWA-PtP products return 255."
|
|
::= { bwaVLServiceParameters 8 }
|
|
|
|
bwaVLMirOnlyOption OBJECT-TYPE
|
|
SYNTAX INTEGER {disable (1), enable (2), na (255)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
Not applicable to BWA-PtP products.
|
|
When bwaMirOnly is enabled, it overrides the CIR/MIR
|
|
algorithm for determining actual information rate and
|
|
forces the algorithm to operate with MIR parameter
|
|
settings only. When enabled, the Graceful Degradation
|
|
algorithm is disabled."
|
|
::= { bwaVLServiceParameters 9 }
|
|
|
|
|
|
bwaVLTrafficPrioritization OBJECT IDENTIFIER ::= {bwaVLServiceParameters 10}
|
|
|
|
bwaVLTrafficPriVLAN OBJECT IDENTIFIER ::= {bwaVLTrafficPrioritization 1}
|
|
|
|
bwaVLVLANPriorityThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (1..7)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
If the VLAN Priority's value of the frame is less than or equal to this
|
|
threshold the frame will get LOW priority, otherwise the frame will get
|
|
HIGH priority.
|
|
Untagged frames will get LOW priority"
|
|
::= { bwaVLTrafficPriVLAN 1 }
|
|
|
|
|
|
bwaVLTrafficPriIPToS OBJECT IDENTIFIER ::= {bwaVLTrafficPrioritization 2}
|
|
|
|
bwaVLToSPrioritizationOption OBJECT-TYPE
|
|
SYNTAX INTEGER {disable(1), ipPrecedence(2), dSCP(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. Disable/Enable IP ToS prioritization and
|
|
choose the interpretation of the IP ToS field from IP header.
|
|
ipPrecedence(2): The IP ToS field is defined by RFC791. In this
|
|
case the prioritization will be done using the
|
|
Precedence sub-field of IP ToS. This sub-field
|
|
has 3 bits, so it can be between 0 and 7.
|
|
dSCP(3): The IP ToS field is defined by RFC2474. In this
|
|
case the prioritization will be done using the
|
|
DSCP sub-field. The size of the sub-field is 6 bits,
|
|
so the range is 0 to 63."
|
|
::= { bwaVLTrafficPriIPToS 1 }
|
|
|
|
bwaVLIPPrecedenceThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. The threshold of Precedence sub-field of IP ToS
|
|
field from IP Header (RFC791) to be used when the ToS Prioritization
|
|
Option is set to IP Precedence.
|
|
If the Precedence sub-field of a frame is less than or equal to this
|
|
threshold the frame will have LOW priority, otherwise it will get HIGH
|
|
priority."
|
|
::= { bwaVLTrafficPriIPToS 2 }
|
|
|
|
bwaVLIPDSCPThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..63)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. The threshold of DSCP sub-field of IP ToS
|
|
field from IP Header (RFC2474) to be used when ToS Prioritization
|
|
Option is set to DSCP.
|
|
If the DSCP sub-field of a frame is less than or equal to this
|
|
threshold the frame will have LOW priority, otherwise it will get
|
|
HIGH priority."
|
|
::= { bwaVLTrafficPriIPToS 3 }
|
|
|
|
|
|
bwaVLTrafficPriUdpTcpPortRange OBJECT IDENTIFIER ::= {bwaVLTrafficPrioritization 3}
|
|
|
|
bwaVLUdpTcpPortRangePrioritizationOption OBJECT-TYPE
|
|
SYNTAX INTEGER {disable(1), udpOnly(2), tcpOnly(3), udpANDtcp(4) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. Disable/Enable Prioritization using UDP and/or
|
|
TCP Port Ranges.
|
|
udpOnly(2) : prioritization will be done only for UDP packets
|
|
tcpOnly(3) : prioritization will be done only for TCP packets
|
|
udpANDtcp(4): prioritization will be done for UDP and TCP packets"
|
|
::= { bwaVLTrafficPriUdpTcpPortRange 1 }
|
|
|
|
bwaVLUdpPortRangeConfig OBJECT IDENTIFIER ::= {bwaVLTrafficPriUdpTcpPortRange 2}
|
|
|
|
bwaVLUdpPortPriRTPRTCP OBJECT-TYPE
|
|
SYNTAX INTEGER {rtpANDrtcp(1),rtpOnly(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicale to all units.
|
|
RTP/RTCP ports prioritization option for UDP packets.
|
|
rtpANDrtcp(1): the possible RTP and RTCP packet with destination port in the
|
|
defined port ranges will get HIGH priority
|
|
rtpOnly(2): only possible RTP packet (packet with even destination port )
|
|
with destination port in the defined port ranges will get HIGH
|
|
priority."
|
|
::= { bwaVLUdpPortRangeConfig 1 }
|
|
|
|
bwaVLUdpPortRangeNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. The number of entries in the UDP Port Range Table"
|
|
::= { bwaVLUdpPortRangeConfig 2 }
|
|
|
|
bwaVLUdpPortRangeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLUdpPortRangeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. A table of UDP port ranges use for prioritization.
|
|
The user can define up to 64 ranges.
|
|
An entry is empty if start is 65535 and end is 0"
|
|
::= { bwaVLUdpPortRangeConfig 3 }
|
|
|
|
bwaVLUdpPortRangeEntry OBJECT-TYPE
|
|
SYNTAX BwaVLUdpPortRangeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. A UDP Port Ranges Table entry."
|
|
INDEX { bwaVLUdpPortRangeIdx }
|
|
::= { bwaVLUdpPortRangeTable 1 }
|
|
|
|
BwaVLUdpPortRangeEntry ::= SEQUENCE {
|
|
bwaVLUdpPortRangeStart INTEGER,
|
|
bwaVLUdpPortRangeEnd INTEGER,
|
|
bwaVLUdpPortRangeIdx INTEGER
|
|
}
|
|
|
|
bwaVLUdpPortRangeStart OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. Start port of an UDP Port Range"
|
|
::= { bwaVLUdpPortRangeEntry 1 }
|
|
|
|
bwaVLUdpPortRangeEnd OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. End port of an UDP Port Range"
|
|
::= { bwaVLUdpPortRangeEntry 2 }
|
|
|
|
bwaVLUdpPortRangeIdx OBJECT-TYPE
|
|
SYNTAX INTEGER(1..64)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. UDP Port Range Entry's index "
|
|
::= { bwaVLUdpPortRangeEntry 3 }
|
|
|
|
|
|
bwaVLUdpPortRangeAdd OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..250))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. Add port range(s) to UDP Port Ranges Table.
|
|
Get operation will return the empty string.
|
|
A range is defined <start>-<end> or <start> where <start> is the Start
|
|
Port of the range and <end> is the End Port. If only <start> is
|
|
specified the range is <start>-<start>.
|
|
The value of <start> and <end> are between 0..65535.
|
|
The user can add several ranges using a comma to separate between ranges.
|
|
Example: 10-256,99,987-900"
|
|
::= { bwaVLUdpPortRangeConfig 4 }
|
|
|
|
bwaVLUdpPortRangeDelete OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..250))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. Delete port range(s) from UDP Port Ranges Table.
|
|
Get operation will return the empty string.
|
|
A range is defined <start>-<end> or <start> where <start> is the Start
|
|
Port of the range and <end> is the End Port. If only <start> is
|
|
specified the range is <start>-<start>.
|
|
The value of <start> and <end> are between 0..65535.
|
|
The user can delete several ranges using a comma to separate between
|
|
ranges.
|
|
Example: 10-256,99,987-900"
|
|
::= { bwaVLUdpPortRangeConfig 5 }
|
|
|
|
bwaVLUdpPortRangeDeleteAll OBJECT-TYPE
|
|
SYNTAX INTEGER { deleteAll(1), cancelOperation(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. Delete all entries form UDP Port Ranges Table.
|
|
Get operation will return 1"
|
|
::= { bwaVLUdpPortRangeConfig 6 }
|
|
|
|
|
|
|
|
bwaVLTcpPortRangeConfig OBJECT IDENTIFIER ::= {bwaVLTrafficPriUdpTcpPortRange 3}
|
|
|
|
bwaVLTcpPortPriRTPRTCP OBJECT-TYPE
|
|
SYNTAX INTEGER {rtpANDrtcp(1),rtpOnly(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. RTP/RTCP ports prioritization option for TCP packets.
|
|
rtpANDrtcp(1): the possible RTP and RTCP packet with destination port
|
|
in the defined port ranges will get HIGH priority
|
|
rtpOnly(2): only possible RTP packet (packet with even destination port )"
|
|
::= { bwaVLTcpPortRangeConfig 1 }
|
|
|
|
bwaVLTcpPortRangeNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. The number of entries in the TCP Port Range Table"
|
|
::= { bwaVLTcpPortRangeConfig 2 }
|
|
|
|
bwaVLTcpPortRangeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLTcpPortRangeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of TCP Port Ranges use for prioritization.
|
|
The user can define up to 64 ranges.
|
|
An entry is empty if start is 65535 and end is 0"
|
|
::= { bwaVLTcpPortRangeConfig 3 }
|
|
|
|
bwaVLTcpPortRangeEntry OBJECT-TYPE
|
|
SYNTAX BwaVLTcpPortRangeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. A TCP Port Ranges Table entry."
|
|
INDEX { bwaVLTcpPortRangeIdx }
|
|
::= { bwaVLTcpPortRangeTable 1 }
|
|
|
|
BwaVLTcpPortRangeEntry ::= SEQUENCE {
|
|
bwaVLTcpPortRangeStart INTEGER,
|
|
bwaVLTcpPortRangeEnd INTEGER,
|
|
bwaVLTcpPortRangeIdx INTEGER
|
|
}
|
|
|
|
bwaVLTcpPortRangeStart OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. Start port of a TCP Port Range"
|
|
::= { bwaVLTcpPortRangeEntry 1 }
|
|
|
|
bwaVLTcpPortRangeEnd OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. End port of a TCP Port Range"
|
|
::= { bwaVLTcpPortRangeEntry 2 }
|
|
|
|
bwaVLTcpPortRangeIdx OBJECT-TYPE
|
|
SYNTAX INTEGER(1..64)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. TCP Port Range Entry's index"
|
|
::= { bwaVLTcpPortRangeEntry 3 }
|
|
|
|
|
|
bwaVLTcpPortRangeAdd OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..250))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. Add port range(s) to TCP Port Ranges Table.
|
|
Get operation will return the empty string.
|
|
A range is defined <start>-<end> or <start> where <start> is the Start
|
|
Port of the range and <end> is the End Port. If only <start> is specified
|
|
the range is <start>-<start>.
|
|
The value of <start> and <end> are between 0..65535.
|
|
The user can add several ranges using comma to separate between ranges.
|
|
Example: 10-256,99,987-900"
|
|
::= { bwaVLTcpPortRangeConfig 4 }
|
|
|
|
bwaVLTcpPortRangeDelete OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..250))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. Delete port range(s) from TCP Port Ranges Table.
|
|
Get operation will return the empty string.
|
|
A range is defined <start>-<end> or <start> where <start> is the Start
|
|
Port of the range and <end> is the End Port. If only <start> is specified
|
|
the range is <start>-<start>.
|
|
The value of <start> and <end> are between 0..65535.
|
|
The user can delete several ranges using comma to separate between ranges.
|
|
Example: 10-256,99,987-900"
|
|
::= { bwaVLTcpPortRangeConfig 5 }
|
|
|
|
bwaVLTcpPortRangeDeleteAll OBJECT-TYPE
|
|
SYNTAX INTEGER { deleteAll(1), cancelOperation(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. Delete all entries form TCP Port Ranges Table
|
|
Get operation will return 1"
|
|
::= { bwaVLTcpPortRangeConfig 6 }
|
|
|
|
bwaVLWirelessLinkPrioritization OBJECT IDENTIFIER ::= {bwaVLTrafficPrioritization 4}
|
|
|
|
bwaVLWirelessLinkPrioritizationOption OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(1), enable(2), na(255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
|
|
Enable/disable the traffic prioritization over the
|
|
Wireless Link"
|
|
::= { bwaVLWirelessLinkPrioritization 1}
|
|
|
|
bwaVLlowPriorityAIFS OBJECT-TYPE
|
|
SYNTAX INTEGER (3..254)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
|
|
Applicable only if the Wireless Link Prioritization Option is enabled.
|
|
Define the AIFS (Arbitration Inter-frame Space) that will be used
|
|
for transmitting Low Priority Traffic"
|
|
::= { bwaVLWirelessLinkPrioritization 2}
|
|
|
|
bwaVLHWRetriesHighPriority OBJECT-TYPE
|
|
SYNTAX INTEGER (0..14)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
|
|
Applicable only if the Wireless Link Prioritization Option is enabled.
|
|
Defines the Maximum number of HW Retries for a unicast data packet
|
|
that has High Priority"
|
|
::= { bwaVLWirelessLinkPrioritization 3}
|
|
|
|
bwaVLHWRetriesLowPriority OBJECT-TYPE
|
|
SYNTAX INTEGER (0..14)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
|
|
Applicable only if the Wireless Link Prioritization Option is enabled.
|
|
Defines the Maximum number of HW Retries for a unicast data packet
|
|
that has Low Priority"
|
|
::= { bwaVLWirelessLinkPrioritization 4}
|
|
|
|
bwaVLAUBurstDurationHighPriority OBJECT-TYPE
|
|
SYNTAX INTEGER (0..40)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
|
|
Applicable only if the Wireless Link Prioritization Option is enabled.
|
|
Defines the Maximum duration of burst that can be done by AU with
|
|
High Priority packets.
|
|
The time is given in 250 microseconds units"
|
|
::= { bwaVLWirelessLinkPrioritization 5}
|
|
|
|
bwaVLAUBurstDurationLowPriority OBJECT-TYPE
|
|
SYNTAX INTEGER (0..40)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
|
|
Applicable only if the Wireless Link Prioritization Option is enabled.
|
|
Defines the Maximum duration of burst that can be done by AU
|
|
with Low Priority packets.
|
|
The time is given in 250 microseconds units"
|
|
::= { bwaVLWirelessLinkPrioritization 6}
|
|
|
|
bwaVLSUBurstDurationHighPriority OBJECT-TYPE
|
|
SYNTAX INTEGER (0..40)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
|
|
Applicable only if the Wireless Link Prioritization Option is enabled.
|
|
Defines the Maximum duration of burst that can be done by SU/RB
|
|
with High Priority packets.
|
|
The parameter is configurable in AU and the SUs/RB will learn it
|
|
form AU/BU.
|
|
The time is given in 250 microseconds units"
|
|
::= { bwaVLWirelessLinkPrioritization 7}
|
|
|
|
bwaVLSUBurstDurationLowPriority OBJECT-TYPE
|
|
SYNTAX INTEGER (0..40)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
|
|
Applicable only if the Wireless Link Prioritization Option is enabled.
|
|
Defines the Maximum duration of burst that can be done by SU/RB
|
|
with High Priority packets.
|
|
The parameter is configurable in AU/BU and the SUs/RB will learn it
|
|
from AU/BU.
|
|
The time is given in 250 microseconds units"
|
|
::= { bwaVLWirelessLinkPrioritization 8}
|
|
|
|
|
|
--DRAP BEGIN
|
|
|
|
bwaVLDrap OBJECT IDENTIFIER ::= { bwaVLServiceParameters 11 }
|
|
|
|
bwaVLDrapSupport OBJECT-TYPE
|
|
SYNTAX INTEGER {disable(1), enable(2), na(255)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU. Not applicable to BWA PtP products.
|
|
Disable/Enable the DRAP feature"
|
|
::= { bwaVLDrap 1 }
|
|
|
|
bwaVLDrapUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (8000..8200)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU when DRAP support is enabled.
|
|
Not applicable to BWA PtP products.
|
|
The UDP port used for the DRAP server"
|
|
::= { bwaVLDrap 2 }
|
|
|
|
bwaVLDrapMaxNumberOfVoiceCalls OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU when DRAP support is enabled.
|
|
Not applicable to BWA PtP products.
|
|
The maximum number of voice calls that can be supported by the AU"
|
|
::= { bwaVLDrap 3 }
|
|
|
|
bwaVLDrapTTL OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU when DRAP support is enabled.
|
|
Not applicable to BWA PtP products.
|
|
The maximum time between two allocation requests"
|
|
::= { bwaVLDrap 4 }
|
|
|
|
bwaVLDrapNoOfActiveVoiceCalls OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU when DRAP support is enabled.
|
|
Not applicable to BWA PtP products.
|
|
The current total number of active voice calls."
|
|
::= { bwaVLDrap 5 }
|
|
|
|
|
|
--DRAP END
|
|
|
|
bwaVLLowPriorityTrafficMinimumPercent OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum percent of the traffic rate that is allocated to the low priority traffic"
|
|
::= { bwaVLServiceParameters 12 }
|
|
|
|
bwaVLSUPMirDownlink OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
The Maximum Information Rate (MIR) from AU to SUP.
|
|
Range for set: 128 to 12,032 (Kbps).
|
|
The actual value (Get) will be the entered value rounded to the nearest
|
|
multiple of 128 (N*128)."
|
|
::= { bwaVLServiceParameters 13 }
|
|
|
|
bwaVLMIRThresholdPercent OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU only.
|
|
MIR Threshold Percent"
|
|
::= { bwaVLServiceParameters 14 }
|
|
|
|
|
|
-- User Filtering Params
|
|
-- =====================
|
|
bwaVLUserFilterParams OBJECT IDENTIFIER ::= {bwaVLMib 8}
|
|
|
|
bwaVLUserFilterOption OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1),
|
|
ipOnly (2),
|
|
userDefinedAddrOnly (3),
|
|
pPPoEOnly (4),
|
|
na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Defines user-filtering options.
|
|
disable: No filtering.
|
|
iPOnly: Only IP protocol frames pass.
|
|
userDefinedAddrOnly: Only ip frames to/from user defined IP
|
|
addresses pass.
|
|
pPPoE Only: Only PPPoE frames pass."
|
|
::= { bwaVLUserFilterParams 1 }
|
|
|
|
bwaVLIpFilterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLIpFilterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
An IP Filter Table of up to 8 user defined addresses,
|
|
or address groups, to be used if the selected User
|
|
Filtering option is userDefinedAddrOnly."
|
|
::= { bwaVLUserFilterParams 2 }
|
|
|
|
bwaVLIpFilterEntry OBJECT-TYPE
|
|
SYNTAX BwaVLIpFilterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
An IP Filter Table entry."
|
|
INDEX { bwaVLIpFilterIdx }
|
|
::= { bwaVLIpFilterTable 1 }
|
|
|
|
BwaVLIpFilterEntry ::= SEQUENCE {
|
|
bwaVLIpID IpAddress,
|
|
bwaVLMaskID IpAddress,
|
|
bwaVLIpFilterRange INTEGER,
|
|
bwaVLIpFilterIdx INTEGER
|
|
}
|
|
|
|
bwaVLIpID OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
An IP address of an IP Filter Table entry."
|
|
::= { bwaVLIpFilterEntry 1 }
|
|
|
|
bwaVLMaskID OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
An IP Mask of an IP Filter Table entry. Either a mask
|
|
or a range, but not both can be used to define an
|
|
address group. If the range is other than 0, than the mask is
|
|
ignored and only the range value is used to define the address group."
|
|
::= { bwaVLIpFilterEntry 2 }
|
|
|
|
bwaVLIpFilterRange OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
An addresses range for the IP Filter Table entry. The
|
|
first address in the range is the IP address.
|
|
O means that the range is not used.
|
|
Either a mask or a range, but not both can be used to
|
|
define an address group.
|
|
If the range is other than 0, than the mask is ignored and
|
|
only the range value is used to define the address group.
|
|
Range: 0 to 255."
|
|
::= { bwaVLIpFilterEntry 3 }
|
|
|
|
bwaVLIpFilterIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
A table index for the IP Filter Table entry."
|
|
::= { bwaVLIpFilterEntry 4 }
|
|
|
|
bwaVLDeleteOneUserFilter OBJECT-TYPE
|
|
SYNTAX INTEGER { deletefirstEntry (1), deletesecondEntry (2),
|
|
deletethirdEntry (3), deletefourthEntry (4),
|
|
deletefifthEntry (5), deletesixthEntry (6),
|
|
deleteseventhEntry(7), deleteeighthEntry (8),
|
|
cancelOperation (9), na (255) }
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Deletes a single selected entry from the IP Filter
|
|
Table."
|
|
::= { bwaVLUserFilterParams 3 }
|
|
|
|
bwaVLDeleteAllUserFilters OBJECT-TYPE
|
|
SYNTAX INTEGER { deleteAll (1), cancelOperation (2),
|
|
na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Deletes all entries from the IP Filter Table."
|
|
::= { bwaVLUserFilterParams 4 }
|
|
|
|
bwaVLDHCPUnicastOverrideFilter OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1), enable (2), na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
Enables or disables the unicast DHCP messages,
|
|
overriding the IP Filtering option."
|
|
::= { bwaVLUserFilterParams 5 }
|
|
|
|
|
|
|
|
-- Security Params
|
|
-- ==================
|
|
bwaVLSecurityParameters OBJECT IDENTIFIER ::= {bwaVLMib 9}
|
|
|
|
bwaVLAuthenticationAlgorithm OBJECT-TYPE
|
|
SYNTAX INTEGER {openSystem(1) , sharedKey(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Enables/disables the authentication encryption option.
|
|
openSystem: Authentication messages are not encrypted.
|
|
sharedKey : Authentication messages are encrypted "
|
|
::= { bwaVLSecurityParameters 1 }
|
|
|
|
bwaVLSUDefaultKeyID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
The key to be used for encryption of authentication messages
|
|
and/or data.
|
|
Range: 1 to 4. "
|
|
::= { bwaVLSecurityParameters 2 }
|
|
|
|
bwaVLDataEncryptionOption OBJECT-TYPE
|
|
SYNTAX INTEGER {disable(1) , enable(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Enables/disables the data encryption option. "
|
|
::= { bwaVLSecurityParameters 3 }
|
|
|
|
bwaVLAUDefaultMulticastKeyID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The key to be used for encryption of multicasts and broadcasts."
|
|
::= { bwaVLSecurityParameters 4 }
|
|
|
|
bwaVLSecurityMode OBJECT-TYPE
|
|
SYNTAX INTEGER {wep(1) , aesOCB(2), fips197(3)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. The fips197 option is applicable only to units with a license to
|
|
use FIPS 197 algorithm.
|
|
The encryption algorithm to be used for authentication messages
|
|
and/or data encryption."
|
|
::= { bwaVLSecurityParameters 5 }
|
|
|
|
|
|
bwaVLAuthenticationPromiscuousMode OBJECT-TYPE
|
|
SYNTAX INTEGER {disable(1) , enable(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Enables/disable the promiscuous mode allowing authentication of
|
|
and communication with all SUs/RB regardless of their security
|
|
parameters."
|
|
::= { bwaVLSecurityParameters 6 }
|
|
|
|
|
|
bwaVLKey1 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Key number 1. Accessible only with SNMP Write Community String
|
|
(administrator password).
|
|
Valid values: 32 hexadecimal digits."
|
|
::= { bwaVLSecurityParameters 7 }
|
|
|
|
bwaVLKey2 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Key number 2. Accessible only with SNMP Write Community String
|
|
(administrator password).
|
|
Valid values: 32 hexadecimal digits."
|
|
::= { bwaVLSecurityParameters 8 }
|
|
|
|
bwaVLKey3 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Key number 3. Accessible only with SNMP Write Community String
|
|
(administrator password).
|
|
Valid values: 32 hexadecimal digits."
|
|
::= { bwaVLSecurityParameters 9 }
|
|
|
|
bwaVLKey4 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Key number 4. Accessible only with SNMP Write Community String
|
|
(administrator password).
|
|
Valid values: 32 hexadecimal digits."
|
|
::= { bwaVLSecurityParameters 10 }
|
|
|
|
bwaVLSecurityModeSupport OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. Returns types of encryption that are supported.
|
|
0 - no encryption
|
|
1 - WEP
|
|
2 - AES OCB
|
|
3 - WEP and AES OCB
|
|
4 - FIPS-197
|
|
5 - FIPS-197 and WEP
|
|
6 - FIPS-197 and AES OCB
|
|
7 - FIPS-197, AES OCB and WEP"
|
|
::= { bwaVLSecurityParameters 12 }
|
|
|
|
|
|
-- Performance Params
|
|
-- ==================
|
|
bwaVLPerformanceParams OBJECT IDENTIFIER ::= {bwaVLMib 10}
|
|
|
|
bwaVLRTSThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU and AU.
|
|
Not applicable to BWA-PtP products.
|
|
The minimum frame size that requires an RTS/CTS handshake.
|
|
Range: For units bearing SW version 3.0 and above: 20 to 3400 bytes,
|
|
for previous SW versions 20 to 1600 bytes.
|
|
BWA-PtP products return 65535."
|
|
::= { bwaVLPerformanceParams 1 }
|
|
|
|
bwaVLMinContentionWindow OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU and AU.
|
|
For units bearing SW version 4.0 and above applicable to
|
|
BWA PtP products, for previous SW versions not applicable
|
|
to BWA PtP products.
|
|
The initial value to be used by the contention window calculation
|
|
algorithm.
|
|
Value must be 0 or power of 2 minus 1 (7,15,31...).
|
|
Range: 0 to 1023, excluding 1 and 3.
|
|
BWA-PtP products with SW version below 4.0 return 65535."
|
|
::= { bwaVLPerformanceParams 3 }
|
|
|
|
bwaVLMaxContentionWindow OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU and AU.
|
|
For units bearing SW version 4.0 and above applicable to
|
|
BWA PtP products, for previous SW versions not applicable
|
|
to BWA PtP products.
|
|
The maximum value to be used by the contention window calculation
|
|
algorithm.
|
|
Value must be power of 2 minus 1 (7,15,31...)
|
|
Range: 7 to 1023."
|
|
::= { bwaVLPerformanceParams 4 }
|
|
|
|
bwaVLMaximumModulationLevel OBJECT-TYPE
|
|
SYNTAX INTEGER { level1 (1),
|
|
level2 (2),
|
|
level3 (3),
|
|
level4 (4),
|
|
level5 (5),
|
|
level6 (6),
|
|
level7 (7),
|
|
level8 (8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
If the Adaptive Modulation algorithm is enabled, it sets the
|
|
Maximum Modulation Level to be used.
|
|
If The Modulation algorithm is disabled, it sets the Fixed
|
|
Modulation Level to be used.
|
|
The range is 1 to 8. 8 is not applicable for units with HW revision A."
|
|
::= { bwaVLPerformanceParams 5 }
|
|
|
|
bwaVLMulticastModulationLevel OBJECT-TYPE
|
|
SYNTAX INTEGER { level1 (1),
|
|
level2 (2),
|
|
level3 (3),
|
|
level4 (4),
|
|
level5 (5),
|
|
level6 (6),
|
|
level7 (7),
|
|
level8 (8)
|
|
}
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The modulation level for multicast and broadcast data frames.
|
|
The range is 1 to 8.
|
|
8 is not applicable for units with HW revision A."
|
|
::= { bwaVLPerformanceParams 6 }
|
|
|
|
bwaVLAvgSNRMemoryFactor OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The weight of history in average SNR calculation.
|
|
The higher is the value, the higher is the weight of history.
|
|
Range: -1 (Disregard History) to 32."
|
|
::= { bwaVLPerformanceParams 7 }
|
|
|
|
bwaVLHardwareRetries OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Not applicable if Wireless Link Prioritization is enabled.
|
|
The maximum number of trials to transmit an unacknowledged
|
|
frame in each Hardware Retrial phase.
|
|
Range : 1 to 14."
|
|
::= { bwaVLPerformanceParams 8 }
|
|
|
|
|
|
bwaVLAdaptiveModulationParams OBJECT IDENTIFIER ::= {bwaVLPerformanceParams 9}
|
|
|
|
bwaVLAdaptiveModulationAlgorithmOption OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1) , enable (2), na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Enables/disables the adaptive modulation level decision mechanism."
|
|
::= { bwaVLAdaptiveModulationParams 1 }
|
|
|
|
|
|
bwaVLSoftwareRetrySupport OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1) , enable (2), na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Read-only for units with version 2.0.
|
|
Not applicable for units with SW version 3.0 and higher.
|
|
The status of the Software Retry mechanism.
|
|
Enabled when the Adaptive Modulation algorithm is enabled and
|
|
the Burst Mode Option is disabled. Otherwise it is disabled."
|
|
::= { bwaVLAdaptiveModulationParams 2 }
|
|
|
|
|
|
bwaVLNumOfSoftwareRetries OBJECT-TYPE
|
|
SYNTAX INTEGER { na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Read-only for units with version 2.0.
|
|
Not applicable for units with SW version 3.0 and higher.
|
|
The maximum number of times to use the Software Retry mechanism
|
|
when it is enabled."
|
|
::= { bwaVLAdaptiveModulationParams 3 }
|
|
|
|
|
|
|
|
bwaVLMinIntervalBetweenAdaptiveModulationAlgorithmMessages OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable all units.
|
|
The minimum interval between two consecutive AU/BU to SU/RB messages.
|
|
Range: 1 to 3600 (Sec)."
|
|
::= { bwaVLAdaptiveModulationParams 4 }
|
|
|
|
bwaVLAdaptiveModulationDecisionThresholds OBJECT-TYPE
|
|
SYNTAX INTEGER { normal (1) , high (2), na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Defines the setting of thresholds for the rate decision algorithm.
|
|
high (2) should typically be used when the SNR is lower than 13dB."
|
|
::= { bwaVLAdaptiveModulationParams 5 }
|
|
|
|
bwaVLBurstMode OBJECT IDENTIFIER ::= {bwaVLPerformanceParams 10}
|
|
|
|
bwaVLBurstModeOption OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1) , enable (2), blocked(3), na (255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Applicable only if Burst Mode Option is supported by country
|
|
specific parameters of the Sub Band.
|
|
Not applicable if Wireless Link Prioritization is enabled.
|
|
Enables/disable burst mode operation.
|
|
In SU/RB with HW Revision B or lower blocked(3) value is returned
|
|
when Security Mode is Wep , Data Encryption Option
|
|
is Enabled and Burst option is Enabled.
|
|
In AU/BU with HW Revision B or lower blocked(3) value is returned
|
|
when Dfs Option is Enabled and Burst mode is enabled."
|
|
::= { bwaVLBurstMode 1 }
|
|
|
|
bwaVLBurstInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Not applicable if Wireless Link Prioritization is enabled.
|
|
Burst mode interval in milliseconds.
|
|
Range: 1 to the maximum value as defined in the country
|
|
specific parameters of the Sub Band (milliseconds)."
|
|
::= { bwaVLBurstMode 2 }
|
|
|
|
bwaVLConcatenationParameters OBJECT IDENTIFIER ::= {bwaVLPerformanceParams 11}
|
|
|
|
bwaVLConcatenationOption OBJECT-TYPE
|
|
SYNTAX INTEGER { disable (1), enable (2), na (255)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Defines the Concatenation option."
|
|
::= { bwaVLConcatenationParameters 1 }
|
|
|
|
bwaVLConcatenationMaximumNumberOfFrames OBJECT-TYPE
|
|
SYNTAX INTEGER (2..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units with SW version 3.X .
|
|
Not applicable for version 4.0 and higher.
|
|
Defines the maximum numbers of frames that can be concatenated.
|
|
Range:2 to 8 (frames)."
|
|
::= { bwaVLConcatenationParameters 2 }
|
|
|
|
bwaVLConcatenationMaxFrameSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Defines the maximum size of a concatenated frame.
|
|
Range:
|
|
256 to 2200 (bytes) for BWA PtP products BU/RB14 BU/RB28,
|
|
or for AU/SU with HW revision A or B.
|
|
256 to 4032 (bytes) for AU/SU with HW Revision
|
|
C or higher and BWA PtP products BU/RB100."
|
|
::= { bwaVLConcatenationParameters 3 }
|
|
|
|
|
|
-- Site Survey Params
|
|
-- ==================
|
|
bwaVLSiteSurvey OBJECT IDENTIFIER ::= {bwaVLMib 11}
|
|
|
|
bwaVLAverageReceiveSNR OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB only.
|
|
The average Signal to Noise Ratio of received frames."
|
|
::= { bwaVLSiteSurvey 1 }
|
|
|
|
-- Traffic Counters
|
|
-- ================
|
|
bwaVLTrafficStatistics OBJECT IDENTIFIER ::= {bwaVLSiteSurvey 2}
|
|
|
|
|
|
bwaVLResetTrafficCounters OBJECT-TYPE
|
|
SYNTAX INTEGER { reset (1),cancel(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Resets the traffic counters."
|
|
::= { bwaVLTrafficStatistics 1 }
|
|
|
|
bwaVLEthCounters OBJECT IDENTIFIER ::= {bwaVLTrafficStatistics 2}
|
|
bwaVLWirelessLinkCounters OBJECT IDENTIFIER ::= {bwaVLTrafficStatistics 3}
|
|
bwaVLWirelessLinkEvents OBJECT IDENTIFIER ::= {bwaVLTrafficStatistics 4}
|
|
|
|
bwaVLPerModulationLevelCounters OBJECT IDENTIFIER ::= {bwaVLTrafficStatistics 5}
|
|
|
|
|
|
bwaVLResetPerModulationLevelCounters OBJECT-TYPE
|
|
SYNTAX INTEGER { resetCounters(1) , cancel (2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Resets the per-Modulation Level counters ."
|
|
::= { bwaVLPerModulationLevelCounters 1 }
|
|
|
|
|
|
|
|
bwaVLSUPerModulationLevelCountersTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLSUPerModulationLevelCountersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB.
|
|
Per Rate Counters table."
|
|
::= { bwaVLPerModulationLevelCounters 2 }
|
|
|
|
bwaVLSUPerModulationLevelCountersEntry OBJECT-TYPE
|
|
SYNTAX BwaVLSUPerModulationLevelCountersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB.
|
|
An entry in the Per modulation Counters table."
|
|
INDEX { bwaVLSUPerModulationLevelCountersTableIdx }
|
|
::= { bwaVLSUPerModulationLevelCountersTable 1 }
|
|
|
|
BwaVLSUPerModulationLevelCountersEntry ::= SEQUENCE {
|
|
bwaVLSUPerModulationLevelCountersTableIdx INTEGER,
|
|
bwaVLSUPerModulationLevelCountersApplicableModLevel INTEGER,
|
|
bwaVLSUPerModulationLevelCountersTxSuccess Counter32,
|
|
bwaVLSUPerModulationLevelCountersTxFailed Counter32
|
|
}
|
|
|
|
|
|
bwaVLSUPerModulationLevelCountersTableIdx OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB.
|
|
An index of an entry in the Per modulation level Counters table."
|
|
::= { bwaVLSUPerModulationLevelCountersEntry 1 }
|
|
|
|
bwaVLSUPerModulationLevelCountersApplicableModLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
modLevel-1 (1),
|
|
modLevel-2 (2),
|
|
modLevel-3 (3),
|
|
modLevel-4 (4),
|
|
modLevel-5 (5),
|
|
modLevel-6 (6),
|
|
modLevel-7 (7),
|
|
modLevel-8 (8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB.
|
|
The applicable modulation level of the entry in the Per
|
|
modulation level Counters table.
|
|
Modulation Level 8 is not applicable for units with HW revision A."
|
|
::= { bwaVLSUPerModulationLevelCountersEntry 2 }
|
|
|
|
|
|
bwaVLSUPerModulationLevelCountersTxSuccess OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB.
|
|
The total number of successfully transmitted unicasts at the
|
|
applicable modulation level."
|
|
::= { bwaVLSUPerModulationLevelCountersEntry 3 }
|
|
|
|
|
|
bwaVLSUPerModulationLevelCountersTxFailed OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB.
|
|
The total number of dropped frames at the applicable
|
|
Modulation Level."
|
|
::= { bwaVLSUPerModulationLevelCountersEntry 4 }
|
|
|
|
|
|
bwaVLAverageModulationLevel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB.
|
|
The average modulation level for successful transmission
|
|
(rounded to nearest integer) since last reset of the
|
|
Per Modulation Level counters.
|
|
Range: 1 to 8."
|
|
::= { bwaVLPerModulationLevelCounters 3 }
|
|
|
|
bwaVLTotalRxFramesViaEthernet OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Total number of frames received via the Ethernet port."
|
|
::= { bwaVLEthCounters 1 }
|
|
|
|
bwaVLTxWirelessToEthernet OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Total number of frames transmitted to the Ethernet port."
|
|
::= { bwaVLEthCounters 2 }
|
|
|
|
bwaVLTxFramesToWireless OBJECT IDENTIFIER ::= {bwaVLWirelessLinkCounters 1}
|
|
|
|
bwaVLAUBeaconsToWireless OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The number of beacons transmitted to the wireless media."
|
|
::= { bwaVLTxFramesToWireless 1 }
|
|
|
|
-- bwaVLOtherMngFramesToWireless OBJECT-TYPE
|
|
-- SYNTAX Counter32
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "Applicable to AU and SU.
|
|
-- The number of management frames transmitted to the wireless media.
|
|
-- In AU, this count does not include Beacons."
|
|
-- ::= { bwaVLTxFramesToWireless 2 }
|
|
|
|
bwaVLDataAndOtherMngFramesToWireless OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The number of data and management frames transmitted to the
|
|
wireless media. The count includes one count for each data
|
|
frame transmitted successfully (excluding retransmissions)."
|
|
::= { bwaVLTxFramesToWireless 3 }
|
|
|
|
bwaVLTotalTxFramesToWireless OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The number of frames transmitted to the wireless media.
|
|
The count includes one count for each data frame
|
|
that was transmitted successfully (excluding retransmissions),
|
|
and also the number of transmitted control and management frames,
|
|
including beacons."
|
|
::= { bwaVLTxFramesToWireless 4 }
|
|
|
|
bwaVLTotalTransmittedUnicasts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The total number of unicast frames successfully transmitted
|
|
to the wireless media, excluding retransmissions."
|
|
::= { bwaVLTxFramesToWireless 5 }
|
|
|
|
bwaVLTotalTransmittedConcatenatedFramesDouble OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all products.
|
|
The total number of double concatenated frames successfully transmitted
|
|
to the wireless media, excluding retransmissions."
|
|
::= { bwaVLTxFramesToWireless 6 }
|
|
|
|
bwaVLTotalTransmittedConcatenatedFramesSingle OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all products.
|
|
The total number of double concatenated frames successfully transmitted
|
|
to the wireless media, excluding retransmissions."
|
|
::= { bwaVLTxFramesToWireless 7 }
|
|
|
|
bwaVLTotalTransmittedConcatenatedFramesMore OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all products.
|
|
The total number of concatenated frames with more then two frames successfully
|
|
transmitted to the wireless media, excluding retransmissions."
|
|
::= { bwaVLTxFramesToWireless 8 }
|
|
|
|
bwaVLTotalRxFramesFromWireless OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The total number of frames that were received
|
|
from the wireless media.
|
|
The count includes data and control and management
|
|
frames, including beacons received from the AU/BU.
|
|
The count does not include frames that were discarded
|
|
internally, bad frames and duplicate frames."
|
|
::= { bwaVLWirelessLinkCounters 2 }
|
|
|
|
bwaVLTotalRetransmittedFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The total number of retransmissions of data frames
|
|
(counts all unsuccessful transmissions/retransmissions)."
|
|
::= { bwaVLWirelessLinkCounters 3 }
|
|
|
|
bwaVLFramesDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The number of dropped frames.
|
|
The frames that were retransmitted to the extent
|
|
of the maximum allowed number of retransmissions
|
|
without being acknowledged.."
|
|
::= { bwaVLWirelessLinkCounters 4 }
|
|
|
|
|
|
bwaVLDataFramesSubmittedToBridge OBJECT IDENTIFIER ::= {bwaVLWirelessLinkCounters 5}
|
|
|
|
bwaVLFramesSubmittedViaHighQueue OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Frames submitted to the internal bridge via the High priority queue.
|
|
for transmission to the wireless media."
|
|
::= { bwaVLDataFramesSubmittedToBridge 1 }
|
|
|
|
bwaVLFramesSubmittedViaMidQueue OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Frames submitted to the internal bridge via the Mid priority queue
|
|
for transmission to the wireless media."
|
|
::= { bwaVLDataFramesSubmittedToBridge 2 }
|
|
|
|
bwaVLFramesSubmittedViaLowQueue OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Frames submitted to the internal bridge via the Low priority queue
|
|
for transmission to the wireless media."
|
|
::= { bwaVLDataFramesSubmittedToBridge 3 }
|
|
|
|
bwaVLTotalNoOfDataFramesSubmitted OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The total number of data frames submitted to the internal bridge
|
|
for transmission to the wireless media."
|
|
::= { bwaVLDataFramesSubmittedToBridge 4 }
|
|
|
|
|
|
bwaVLTotalRecievedDataFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The total number of data frames received from the
|
|
wireless media, including duplicate frames."
|
|
::= { bwaVLWirelessLinkCounters 6 }
|
|
|
|
bwaVLRecievedBadFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The number of frames received from the wireless
|
|
media with errors (CRC errors)."
|
|
::= { bwaVLWirelessLinkCounters 7 }
|
|
|
|
bwaVLNoOfDuplicateFramesDiscarded OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The number of frames discarded due to receiving multiple copies."
|
|
::= { bwaVLWirelessLinkCounters 8 }
|
|
|
|
bwaVLNoOfInternallyDiscardedMirCir OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The number of data frames received from the Ethernet port that were
|
|
discarded by the MIR/CIR mechanism either to avoid exceeding the
|
|
maximum allowed information rate, or when the wireless link conditions
|
|
do not enable reaching the allowed rate."
|
|
::= { bwaVLWirelessLinkCounters 9 }
|
|
|
|
bwaVLTotalRxConcatenatedFramesDouble OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The total number of double concatenated frames received
|
|
from the wireless media, including duplicate frames."
|
|
::= { bwaVLWirelessLinkCounters 10 }
|
|
|
|
bwaVLTotalRxConcatenatedFramesSingle OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The total number of data fast frames single concatenated
|
|
frames received from the wireless media, including duplicate frames."
|
|
::= { bwaVLWirelessLinkCounters 11 }
|
|
|
|
bwaVLTotalRxConcatenatedFramesMore OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The total number of data fast frames concatenated with more then two
|
|
frames received from the wireless media, including duplicate frames."
|
|
::= { bwaVLWirelessLinkCounters 12 }
|
|
|
|
-- bwaVLInternallyGeneratedFramesSubmittedToBridge OBJECT-TYPE
|
|
-- SYNTAX Counter32
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "Applicable to SU and AU. Read-only.
|
|
-- The number of internally generated frames(wireless management and control frames)
|
|
-- submitted to the bridge for transmission to the wireless media."
|
|
-- ::= { bwaVLWirelessLinkCounters 10 }
|
|
|
|
|
|
bwaVLTxEvents OBJECT IDENTIFIER ::= {bwaVLWirelessLinkEvents 1}
|
|
|
|
bwaVLDroppedFrameEvents OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The number of frames that were dropped because they were retransmitted
|
|
to the maximum allowed number of retransmissions without being
|
|
acknowledged."
|
|
::= { bwaVLTxEvents 1 }
|
|
|
|
bwaVLFramesDelayedDueToSwRetry OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Not applicable for units with SW Version 3.0 and higher.
|
|
The number of frames that were delayed because the SW retry
|
|
algorithm was activated on a previous frame designated for the
|
|
same recipient."
|
|
::= { bwaVLTxEvents 2 }
|
|
|
|
bwaVLUnderrunEvents OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The number of frames whose transmission was aborted because the rate
|
|
of submitting frames for transmission exceeded the available
|
|
transmission capability."
|
|
::= { bwaVLTxEvents 3 }
|
|
|
|
bwaVLOthersTxEvents OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The number of Tx events due to problems other than those of
|
|
the other Tx Events counters."
|
|
::= { bwaVLTxEvents 4 }
|
|
|
|
bwaVLTotalTxEvents OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The total number of Tx special events."
|
|
::= { bwaVLTxEvents 5 }
|
|
|
|
bwaVLRxEvents OBJECT IDENTIFIER ::= {bwaVLWirelessLinkEvents 2}
|
|
|
|
bwaVLPhyErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units, only when DFS is enabled.
|
|
The number of unidentified signals."
|
|
::= { bwaVLRxEvents 1 }
|
|
|
|
bwaVLCRCErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The number of frames received from the wireless media containing
|
|
CRC errors."
|
|
::= { bwaVLRxEvents 2 }
|
|
|
|
bwaVLOverrunEvents OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The number of frames that were discarded because the receive
|
|
rate exceeded the processing capability or the capacity of the
|
|
Ethernet port."
|
|
::= { bwaVLRxEvents 3 }
|
|
|
|
bwaVLRxDecryptEvents OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The number of frames that were not received properly due to a
|
|
problem in the data decryption mechanism."
|
|
::= { bwaVLRxEvents 4 }
|
|
|
|
bwaVLTotalRxEvents OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The total number of Rx special events."
|
|
::= { bwaVLRxEvents 5 }
|
|
|
|
|
|
-- Associations Database
|
|
--
|
|
bwaVLMacAddressDatabase OBJECT IDENTIFIER ::= {bwaVLSiteSurvey 5}
|
|
|
|
bwaVLAUMacAddressDatabase OBJECT IDENTIFIER ::= {bwaVLMacAddressDatabase 1}
|
|
|
|
bwaVLAUAdbResetAllModulationLevelCounters OBJECT-TYPE
|
|
SYNTAX INTEGER { reset (1), cancel (2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
To reset all the counters for all SUs/RB in the MAC Address Database."
|
|
::= { bwaVLAUMacAddressDatabase 1 }
|
|
|
|
bwaVLAUAdbTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLAUAdbEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
AU/BU MAC Address Database table."
|
|
::= { bwaVLAUMacAddressDatabase 2 }
|
|
|
|
bwaVLAUAdbEntry OBJECT-TYPE
|
|
SYNTAX BwaVLAUAdbEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
An entry in the AU/BU MAC Address Database table."
|
|
INDEX { bwaVLAdbIndex }
|
|
::= { bwaVLAUAdbTable 1 }
|
|
|
|
|
|
BwaVLAUAdbEntry ::= SEQUENCE {
|
|
bwaVLAdbIndex INTEGER,
|
|
bwaVLAdbMacAddress MacAddress,
|
|
bwaVLAdbStatus INTEGER,
|
|
bwaVLAdbSwVersion DisplayString,
|
|
bwaVLAdbSNR INTEGER,
|
|
bwaVLAdbMaxModulationLevel INTEGER,
|
|
bwaVLAdbTxFramesTotal Counter32,
|
|
bwaVLAdbDroppedFramesTotal Counter32,
|
|
bwaVLAdbTxSuccessModLevel1 Counter32,
|
|
bwaVLAdbTxSuccessModLevel2 Counter32,
|
|
bwaVLAdbTxSuccessModLevel3 Counter32,
|
|
bwaVLAdbTxSuccessModLevel4 Counter32,
|
|
bwaVLAdbTxSuccessModLevel5 Counter32,
|
|
bwaVLAdbTxSuccessModLevel6 Counter32,
|
|
bwaVLAdbTxSuccessModLevel7 Counter32,
|
|
bwaVLAdbTxSuccessModLevel8 Counter32,
|
|
bwaVLAdbTxFailedModLevel1 Counter32,
|
|
bwaVLAdbTxFailedModLevel2 Counter32,
|
|
bwaVLAdbTxFailedModLevel3 Counter32,
|
|
bwaVLAdbTxFailedModLevel4 Counter32,
|
|
bwaVLAdbTxFailedModLevel5 Counter32,
|
|
bwaVLAdbTxFailedModLevel6 Counter32,
|
|
bwaVLAdbTxFailedModLevel7 Counter32,
|
|
bwaVLAdbTxFailedModLevel8 Counter32,
|
|
bwaVLAdbCirTx INTEGER,
|
|
bwaVLAdbMirTx INTEGER,
|
|
bwaVLAdbCirRx INTEGER,
|
|
bwaVLAdbMirRx INTEGER,
|
|
bwaVLAdbCirMaxDelay INTEGER,
|
|
bwaVLAdbDistance INTEGER,
|
|
bwaVLAdbHwRevision INTEGER,
|
|
bwaVLAdbCpldVer DisplayString,
|
|
bwaVLAdbCountryCode INTEGER,
|
|
bwaVLAdbBootVer DisplayString,
|
|
bwaVLAdbAtpcOption INTEGER,
|
|
bwaVLAdbAdapModOption INTEGER,
|
|
bwaVLAdbBurstModeOption INTEGER,
|
|
bwaVLAdbConcatenationOption INTEGER,
|
|
bwaVLAdbSecurityMode INTEGER,
|
|
bwaVLAdbAuthOption INTEGER,
|
|
bwaVLAdbDataEncyptOption INTEGER,
|
|
bwaVLAdbAge INTEGER,
|
|
bwaVLAdbUnitName DisplayString
|
|
}
|
|
|
|
bwaVLAdbIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..512)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The index of an entry in the AU/BU MAC Address Database table."
|
|
::= { bwaVLAUAdbEntry 1 }
|
|
|
|
bwaVLAdbMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The MAC Address of an SU/RB entry in the MAC Address Database
|
|
table."
|
|
::= { bwaVLAUAdbEntry 2 }
|
|
|
|
bwaVLAdbStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { associated (1),
|
|
authenticated (2),
|
|
notAuthenticated (3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The status of the relevant SU/RB."
|
|
::= { bwaVLAUAdbEntry 3 }
|
|
|
|
bwaVLAdbSwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The SW version of the relevant SU/RB."
|
|
::= { bwaVLAUAdbEntry 4 }
|
|
|
|
bwaVLAdbSNR OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The average Signal to Noise Ratio in dB of frames received by
|
|
the AU/BU from the relevant SU/RB."
|
|
::= { bwaVLAUAdbEntry 5 }
|
|
|
|
bwaVLAdbMaxModulationLevel OBJECT-TYPE
|
|
SYNTAX INTEGER { modLevel-1 (1),
|
|
modLevel-2 (2),
|
|
modLevel-3 (3),
|
|
modLevel-4 (4),
|
|
modLevel-5 (5),
|
|
modLevel-6 (6),
|
|
modLevel-7 (7),
|
|
modLevel-8 (8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The value configured in the relevant SU/RB for the Maximum Modulation
|
|
Level parameter.
|
|
Modulation Level 8 is not applicable for units with HW revision A."
|
|
::= { bwaVLAUAdbEntry 6 }
|
|
|
|
bwaVLAdbTxFramesTotal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Counts the total number of unicast frames (excluding retransmissions)
|
|
that were successfully transmitted to the SU/RB over the wireless link."
|
|
::= { bwaVLAUAdbEntry 7 }
|
|
|
|
bwaVLAdbDroppedFramesTotal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Counts the total number of frames intended to the SU/RB that
|
|
were dropped because they were retransmitted to the extent
|
|
of the maximum allowed number of retransmissions without
|
|
being acknowledged."
|
|
::= { bwaVLAUAdbEntry 8 }
|
|
|
|
bwaVLAdbTxSuccessModLevel1 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Counts the total number of unicast frames (excluding retransmissions)
|
|
that were successfully transmitted to the SU/RB over the wireless link
|
|
using modulation level 1."
|
|
::= { bwaVLAUAdbEntry 9 }
|
|
|
|
bwaVLAdbTxSuccessModLevel2 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Counts the total number of unicast frames (excluding retransmissions)
|
|
that were successfully transmitted to the SU/RB over the wireless link
|
|
using modulation level 2."
|
|
::= { bwaVLAUAdbEntry 10 }
|
|
|
|
bwaVLAdbTxSuccessModLevel3 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Counts the total number of unicast frames (excluding retransmissions)
|
|
that were successfully transmitted to the SU/BU over the wireless link
|
|
using modulation level 3."
|
|
::= { bwaVLAUAdbEntry 11 }
|
|
|
|
bwaVLAdbTxSuccessModLevel4 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Counts the total number of unicast frames (excluding retransmissions)
|
|
that were successfully transmitted to the SU/RB over the wireless link
|
|
using modulation level 4."
|
|
::= { bwaVLAUAdbEntry 12 }
|
|
|
|
bwaVLAdbTxSuccessModLevel5 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Counts the total number of unicast frames (excluding retransmissions)
|
|
that were successfully transmitted to the SU/RB over the wireless link
|
|
using modulation level 5."
|
|
::= { bwaVLAUAdbEntry 13 }
|
|
|
|
bwaVLAdbTxSuccessModLevel6 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Counts the total number of unicast frames (excluding retransmissions)
|
|
that were successfully transmitted to the SU/BU over the wireless link
|
|
using modulation level 6."
|
|
::= { bwaVLAUAdbEntry 14 }
|
|
|
|
bwaVLAdbTxSuccessModLevel7 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Counts the total number of unicast frames (excluding retransmissions)
|
|
that were successfully transmitted to the SU/RB over the wireless link
|
|
using modulation level 7."
|
|
::= { bwaVLAUAdbEntry 15 }
|
|
|
|
bwaVLAdbTxSuccessModLevel8 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Counts the total number of unicast frames (excluding retransmissions)
|
|
that were successfully transmitted to the SU/RB over the wireless link
|
|
using modulation level 8.
|
|
Not applicable for units with HW revision A."
|
|
::= { bwaVLAUAdbEntry 16 }
|
|
|
|
bwaVLAdbTxFailedModLevel1 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Counts the total number of failures to successfully
|
|
transmit unicast frames intended to the SU/RB using modulation level 1."
|
|
::= { bwaVLAUAdbEntry 17 }
|
|
|
|
bwaVLAdbTxFailedModLevel2 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Counts the total number of failures to successfully
|
|
transmit unicast frames intended to the SU/RB using modulation level 2."
|
|
::= { bwaVLAUAdbEntry 18 }
|
|
|
|
bwaVLAdbTxFailedModLevel3 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Counts the total number of failures to successfully
|
|
transmit unicast frames intended to the SU/RB using modulation level 3."
|
|
::= { bwaVLAUAdbEntry 19 }
|
|
|
|
bwaVLAdbTxFailedModLevel4 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Counts the total number of failures to successfully
|
|
transmit unicast frames intended to the SU/RB using modulation level 4."
|
|
::= { bwaVLAUAdbEntry 20 }
|
|
|
|
bwaVLAdbTxFailedModLevel5 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Counts the total number of failures to successfully
|
|
transmit unicast frames intended to the SU/RB using modulation level 5."
|
|
::= { bwaVLAUAdbEntry 21 }
|
|
|
|
bwaVLAdbTxFailedModLevel6 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Counts the total number of failures to successfully
|
|
transmit unicast frames intended to the SU/RB using modulation level 6."
|
|
::= { bwaVLAUAdbEntry 22 }
|
|
|
|
bwaVLAdbTxFailedModLevel7 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Counts the total number of failures to successfully
|
|
transmit unicast frames intended to the SU/RB using modulation level 7."
|
|
::= { bwaVLAUAdbEntry 23 }
|
|
|
|
bwaVLAdbTxFailedModLevel8 OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Counts the total number of failures to successfully
|
|
transmit unicast frames intended to the SU/RB using modulation level 8.
|
|
Not applicable for units with HW revision A."
|
|
::= { bwaVLAUAdbEntry 24 }
|
|
|
|
bwaVLAdbCirTx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU Only.
|
|
Not applicable to BWA-PtP products. Read-only.
|
|
The value configured in the relevant SU for the CIR:
|
|
SU to AU parameter."
|
|
::= { bwaVLAUAdbEntry 25 }
|
|
|
|
bwaVLAdbMirTx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The value configured in the relevant SU/RB for the MIR:
|
|
SU/RB to AU/BU parameter."
|
|
::= { bwaVLAUAdbEntry 26 }
|
|
|
|
bwaVLAdbCirRx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU Only.
|
|
Not applicable to BWA-PtP products.
|
|
The value configured in the relevant SU for the CIR:
|
|
AU to SU parameter."
|
|
::= { bwaVLAUAdbEntry 27 }
|
|
|
|
bwaVLAdbMirRx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The value configured in the relevant SU/RB for the MIR:
|
|
AU/BU to SU/RB parameter."
|
|
::= { bwaVLAUAdbEntry 28 }
|
|
|
|
bwaVLAdbCirMaxDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU Only.
|
|
Not applicable to BWA-PtP products.
|
|
The value configured in the relevant SU for the CIR Maximum
|
|
Delay parameter."
|
|
::= { bwaVLAUAdbEntry 29 }
|
|
|
|
bwaVLAdbDistance OBJECT-TYPE
|
|
SYNTAX INTEGER {below-2-Km(1)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU Only.
|
|
The distance between the SU/RB and the AU/BU (In Kilometers)."
|
|
::= { bwaVLAUAdbEntry 30 }
|
|
|
|
bwaVLAdbHwRevision OBJECT-TYPE
|
|
SYNTAX INTEGER {hwRevisionA(1), hwRevisionB(2), hwRevisionC(3),
|
|
hwRevisionD(4), hwRevisionE(5), na(255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU Only.
|
|
The SU/RB HW Revision."
|
|
::= { bwaVLAUAdbEntry 31 }
|
|
|
|
bwaVLAdbCpldVer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU Only.
|
|
The SU/RB CPLD Version."
|
|
::= { bwaVLAUAdbEntry 32 }
|
|
|
|
bwaVLAdbCountryCode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU Only.
|
|
The SU/RB supported country code."
|
|
::= { bwaVLAUAdbEntry 33 }
|
|
|
|
bwaVLAdbBootVer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU Only.
|
|
The SU/RB Boot Version."
|
|
::= { bwaVLAUAdbEntry 34 }
|
|
|
|
bwaVLAdbAtpcOption OBJECT-TYPE
|
|
SYNTAX INTEGER {disable (1), enable (2), na (255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU Only.
|
|
The SU/RB ATPC option configuration."
|
|
::= { bwaVLAUAdbEntry 35 }
|
|
|
|
bwaVLAdbAdapModOption OBJECT-TYPE
|
|
SYNTAX INTEGER {disable (1), enable (2), na (255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU Only.
|
|
The SU/RB adaptive modulation option configuration."
|
|
::= { bwaVLAUAdbEntry 36 }
|
|
|
|
bwaVLAdbBurstModeOption OBJECT-TYPE
|
|
SYNTAX INTEGER {disable (1), enable (2), na (255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU Only.
|
|
The SU/RB burst mode option configuration."
|
|
::= { bwaVLAUAdbEntry 37 }
|
|
|
|
bwaVLAdbConcatenationOption OBJECT-TYPE
|
|
SYNTAX INTEGER {disable (1), enable (2), na(255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU Only.
|
|
The SU/RB concatenation option configuration."
|
|
::= { bwaVLAUAdbEntry 39 }
|
|
|
|
bwaVLAdbSecurityMode OBJECT-TYPE
|
|
SYNTAX INTEGER {wep(1), aes(2), fips197(3), na(255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU Only.
|
|
The SU/RB security mode configuration."
|
|
::= { bwaVLAUAdbEntry 41 }
|
|
|
|
bwaVLAdbAuthOption OBJECT-TYPE
|
|
SYNTAX INTEGER {openSystem (1), sharedKey (2), na (255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU Only.
|
|
The SU/RB authentication algorithm configuration."
|
|
::= { bwaVLAUAdbEntry 42 }
|
|
|
|
bwaVLAdbDataEncyptOption OBJECT-TYPE
|
|
SYNTAX INTEGER {disable (1), enable (2), na (255)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU Only.
|
|
The SU/RB data encryption option configuration."
|
|
::= { bwaVLAUAdbEntry 43 }
|
|
|
|
bwaVLAdbAge OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The time since any packet was received from the relevant SU/RB."
|
|
::= { bwaVLAUAdbEntry 44 }
|
|
|
|
bwaVLAdbUnitName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The unit name of the relevant SU/RB."
|
|
::= { bwaVLAUAdbEntry 45 }
|
|
|
|
bwaVLUpLinkQualityIndicator OBJECT IDENTIFIER ::= { bwaVLSiteSurvey 6}
|
|
|
|
bwaVLMeasureUpLinkQualityIndicator OBJECT-TYPE
|
|
SYNTAX INTEGER { start (1) , cancel (2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB.
|
|
Starts calculation of LQI.
|
|
The calculation will be for a period of 10 seconds."
|
|
::= { bwaVLUpLinkQualityIndicator 1 }
|
|
|
|
|
|
bwaVLReadUpLinkQualityIndicator OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB.
|
|
The results of the last LQI calculation.
|
|
Range: 1 to 8."
|
|
::= { bwaVLUpLinkQualityIndicator 2 }
|
|
|
|
|
|
bwaVLUpLinkQualityIndicatorStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {fullTest(1) , limitedTest(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to SU/RB Only.
|
|
Indicates the test conditions.
|
|
fullTest means that there are no limitations
|
|
on the range of available modulation levels, and that all modulation levels
|
|
from 1 to 8 can be used.
|
|
limitedTest indicates that the results may not indicate the true quality since
|
|
the available range is limited - by HW (HW Revision A),
|
|
or by the applicable parameters in the country code,
|
|
or by the configurable Maximum Modulation Level parameter."
|
|
::= { bwaVLUpLinkQualityIndicator 3 }
|
|
|
|
-- AC pinpoint table end
|
|
|
|
bwaVLMacPinpoint OBJECT IDENTIFIER ::= {bwaVLSiteSurvey 7}
|
|
|
|
bwaVLMacPinpointTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLMacPinpointEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
A table that contains information about wireless device
|
|
used by a certain Ethernet station in order to
|
|
connect to the wireless network"
|
|
::= { bwaVLMacPinpoint 1 }
|
|
|
|
bwaVLMacPinpointEntry OBJECT-TYPE
|
|
SYNTAX BwaVLMacPinpointEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only. An entry in the MAC Pinpoint Table.
|
|
Each entry contains an Ethernet station MAC address and the MAC
|
|
address of the wireless device used to connect it to the wireless
|
|
network"
|
|
INDEX { mptEthernetStationMACAddress }
|
|
::= { bwaVLMacPinpointTable 1 }
|
|
|
|
BwaVLMacPinpointEntry ::=
|
|
SEQUENCE {
|
|
mptEthernetStationMACAddress
|
|
MacAddress,
|
|
mptUnitMACAddress
|
|
MacAddress
|
|
}
|
|
|
|
mptEthernetStationMACAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
The MAC address of the Ethernet station. It is used as an
|
|
index in the MAC Pinpoint Table."
|
|
::= { bwaVLMacPinpointEntry 1 }
|
|
|
|
mptUnitMACAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only. The MAC address of the wireless
|
|
device used by the station with the MAC Address from the
|
|
index in order to access the wireless network."
|
|
::= { bwaVLMacPinpointEntry 2 }
|
|
-- AC pinpoint table end
|
|
|
|
-- GATEWAY TABLE BEGIN
|
|
|
|
bwaVLDrapGatewaysTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BwaVLDrapGatewayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table provides information about Gateways supporting DRAP that are
|
|
registered at the AU"
|
|
::= { bwaVLSiteSurvey 8 }
|
|
|
|
bwaVLDrapGatewayEntry OBJECT-TYPE
|
|
SYNTAX BwaVLDrapGatewayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Drap Gateway Entry."
|
|
INDEX { bwaVLDrapGatewayIndex }
|
|
::= { bwaVLDrapGatewaysTable 1 }
|
|
|
|
BwaVLDrapGatewayEntry ::= SEQUENCE {
|
|
bwaVLDrapGatewayIndex INTEGER,
|
|
bwaVLDrapGatewayIP IpAddress,
|
|
bwaVLDrapGatewayType INTEGER,
|
|
bwaVLDrapGatewayNoOfActiveVoiceCalls INTEGER
|
|
}
|
|
|
|
bwaVLDrapGatewayIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..512)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway Entry's Index"
|
|
::= { bwaVLDrapGatewayEntry 1 }
|
|
|
|
bwaVLDrapGatewayIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address of the Gateway"
|
|
::= { bwaVLDrapGatewayEntry 2 }
|
|
|
|
bwaVLDrapGatewayType OBJECT-TYPE
|
|
SYNTAX INTEGER { vgDataVoice (4), vgData1Voice1 (5),
|
|
vgData4Voice2 (6), vgDataVoice2(7),
|
|
ngData4Wireless (11),
|
|
vgUnknown(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Gateway type"
|
|
::= { bwaVLDrapGatewayEntry 3 }
|
|
|
|
bwaVLDrapGatewayNoOfActiveVoiceCalls OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current number of active voice calls handled by the Gateway"
|
|
::= { bwaVLDrapGatewayEntry 4 }
|
|
|
|
-- GATEWAY TABLE END
|
|
|
|
-- ****************************************************************************************
|
|
-- TRAP defenitions:
|
|
-- ****************************************************************************************
|
|
|
|
bwaVLTraps OBJECT IDENTIFIER ::= { bwaVLMib 14 }
|
|
|
|
bwaVLTrapSUMacAddr OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
SU/RB MAC Address."
|
|
::= { bwaVLTraps 1 }
|
|
|
|
--bwaVLTrapSNRQuality OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "Applicable to SU only.
|
|
-- SNR of received signal."
|
|
-- ::= { bwaVLTraps 2 }
|
|
|
|
bwaVLTrapText OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Textual string for future use."
|
|
::= { bwaVLTraps 3 }
|
|
|
|
bwaVLTrapToggle OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
on (1),
|
|
off (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
An On/Off toggle status."
|
|
::= { bwaVLTraps 4 }
|
|
|
|
bwaVLTrapParameterChanged OBJECT-TYPE
|
|
SYNTAX INTEGER{ cirOrMir (1),
|
|
ipFilter (2),
|
|
vlan (4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
A modification to one of the parameters related to CIR/MIR,
|
|
IP Filtering or VLAN."
|
|
::= { bwaVLTraps 5 }
|
|
|
|
bwaVLTrapAccessRights OBJECT-TYPE
|
|
SYNTAX INTEGER{ notLoggedIn (1),
|
|
readOnly (2),
|
|
installer (3),
|
|
administrator (4),
|
|
factory (5) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The access rights used for login."
|
|
::= { bwaVLTraps 6 }
|
|
|
|
bwaVLTrapLog OBJECT-TYPE
|
|
SYNTAX INTEGER{ telnetLogin (3),
|
|
telnetLogout (4) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
Login or logout to the Monitor program via Telnet."
|
|
::= { bwaVLTraps 7 }
|
|
|
|
bwaVLTrapTelnetUserIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The IP address of a Telnet user."
|
|
::= { bwaVLTraps 8 }
|
|
|
|
bwaVLTrapRTx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
Retransmissions as a percentage of total transmissions."
|
|
::= { bwaVLTraps 9 }
|
|
|
|
bwaVLTrapFtpOrTftpStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
successful (1),
|
|
failed (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The status of the last FTP/TFTP loading procedure."
|
|
::= { bwaVLTraps 10 }
|
|
|
|
bwaVLDFSMoveFreq OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU with HW revision B and lower
|
|
(for units with HW revision C and higher replaced by
|
|
bwaVLTrapDFSMoveFreq New to support a resolution of 0.5 MHz).
|
|
The new frequency in MHz after detecting radar on a previous channel."
|
|
::= { bwaVLTraps 11 }
|
|
|
|
bwaVLDFSMoveFreqNew OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU.
|
|
The new frequency in MHz after detecting radar on a previous channel.
|
|
(Replaces bwaVLDFSMoveFreq to support a resolution of 0.5 MHz for
|
|
units with HW revision C and higher)."
|
|
::= { bwaVLTraps 12 }
|
|
|
|
|
|
bwaVLEthBroadcastThresholdExceeded OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
The number of packets that are dropped by the ethernet broadcast/multicast limiter."
|
|
::= { bwaVLTraps 13 }
|
|
|
|
|
|
bwaVLTrapSubscriberType OBJECT-TYPE
|
|
SYNTAX INTEGER{ unknownSubscriberType(0),
|
|
su-3(3) , su-6(6) , rb-14(14),
|
|
su-24(24), rb-28(28), su-54(54),
|
|
rb-100(100) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AUS only.
|
|
The type of subscriber that was rejected by AUS"
|
|
::= { bwaVLTraps 14 }
|
|
|
|
|
|
bwaVLTrapMACAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to BU/RB only.
|
|
The MAC address of the BWA PtP unit whose type has been changed"
|
|
::= { bwaVLTraps 15 }
|
|
|
|
bwaVLNewUnitTypeTrap OBJECT-TYPE
|
|
SYNTAX INTEGER { bu(1), rb(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to BU/RB only.
|
|
The new type of the BWA PtP unit."
|
|
::= { bwaVLTraps 16 }
|
|
|
|
bwaVLTrapSWVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SW version of the SU that tries to associate
|
|
with a station that has Wireless Link Prioritization Enabled"
|
|
::= { bwaVLTraps 17 }
|
|
|
|
--
|
|
-- Private Traps for BWA-PtMP
|
|
--
|
|
|
|
bwaVLSUassociatedAUTRAP NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
bwaVLTrapSUMacAddr -- SU MAC address
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An AU/BU trap indicating a new association with an SU/RB."
|
|
::= { bwaVLProducts 2 }
|
|
|
|
bwaVLAUdisassociatedTRAP NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
bwaVLTrapSUMacAddr --Unit MAC address
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An AU/BU trap indicating that an SU/RB has been disassociated
|
|
from the AU.
|
|
The AU/BU decides that an SU/RB has been disassociated from it and remove it
|
|
from the ADB after receiving from another AU/BU a SNAP frame with the SU/RB
|
|
MAC address.
|
|
The SNAP frame indicating a network topology change where the SU/RB has
|
|
associated with another AU/BU will be received if both AUs/BUs are
|
|
connected to the same Ethernet backbone."
|
|
::= { bwaVLProducts 3 }
|
|
|
|
bwaVLAUagingTRAP NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
bwaVLTrapSUMacAddr -- Unit MAC address
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An AU/BU trap indicating that the unit association was aged out
|
|
and removed from the Association database following its failure
|
|
to acknowledge a specified number of consecutive frames."
|
|
::= { bwaVLProducts 4 }
|
|
|
|
bwaVLSUassociatedTRAP NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
-- bwaVLLastAUMacAddress, Old AU mac address
|
|
bwaVLAssociatedAU -- New AU mac address
|
|
-- bwaVLTrapLastSNRQuality, Average SNR with old AU
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An SU/RB trap indicating association with an AU/BU.
|
|
In addition to the MAC address information of the AU/BU, the
|
|
trap also includes information on the average SNR of frames
|
|
received from the AU/BU."
|
|
::= { bwaVLProducts 6 }
|
|
|
|
bwaVLAUwirelessQualityTRAP NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
bwaVLTrapToggle,
|
|
bwaVLTrapRTx
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An AU/BU trap, indicating that the quality of the wireless
|
|
link (retransmissions rate) has changed and dropped below (Off) or increased
|
|
above (On) a threshold , defined by the *bwaVLWirelessTrapThreshold.
|
|
The threshold for AU/BU is a percentage of retransmissions."
|
|
::= { bwaVLProducts 20 }
|
|
|
|
bwaVLPowerUpFromReset NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
bwaVLUnitMacAddress -- Unit MAC address
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An AU/BU trap indicating power up after Reset."
|
|
::= { bwaVLProducts 101 }
|
|
|
|
bwaVLTelnetStatusTRAP NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
bwaVLTrapLog,
|
|
bwaVLTrapAccessRights,
|
|
bwaVLTrapTelnetUserIpAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
A trap indicating that a log-in or log-out has been performed
|
|
via Telnet. Includes the log-in access
|
|
right and the IP address of the PC performing Telnet."
|
|
::= { bwaVLProducts 102 }
|
|
|
|
bwaVLParameterChangedTRAP NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
bwaVLTrapParameterChanged
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. A trap indicating a change in a CIR/MIR, IP Filter
|
|
or VLAN parameter."
|
|
::= { bwaVLProducts 103 }
|
|
|
|
bwaVLLoadingStatusTRAP NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
bwaVLTrapFtpOrTftpStatus,
|
|
bwaVLUnitMacAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units.
|
|
A trap indicating that last FTP/TFTP loading process has been
|
|
finished successfully or failed. "
|
|
::= { bwaVLProducts 104 }
|
|
|
|
bwaVLPromiscuousModeTRAP NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
bwaVLTrapToggle,
|
|
bwaVLUnitMacAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An AU/BU trap, indicating that the AU/BU In (On) Promiscuous Mode or
|
|
out (Off) Promiscuous Mode."
|
|
::= { bwaVLProducts 105 }
|
|
|
|
bwaVLDFSRadarDetecetedTRAP NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DFS: Applicable to AU/BU only.
|
|
A trap indicating that a radar was detected. "
|
|
::= { bwaVLProducts 106 }
|
|
|
|
bwaVLDFSFrequcnyTRAP NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
bwaVLDFSMoveFreq,
|
|
bwaVLDFSMoveFreqNew
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
A trap indicating that the unit moved to a new frequency. "
|
|
::= { bwaVLProducts 107 }
|
|
|
|
bwaVLDFSNoFreeChannelsExistsTRAP NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
A trap indicating that a radar was detected and there is no
|
|
free channel. "
|
|
::= { bwaVLProducts 108 }
|
|
|
|
bwaVLEthBroadcastMulticatLimiterTRAP NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
bwaVLEthBroadcastThresholdExceeded
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to all units. The trap is send if the
|
|
ethernet broadcast filter threshold is exceeded
|
|
and it contains the number of dropped packets."
|
|
::= { bwaVLProducts 109 }
|
|
|
|
bwaVLAUSUnsupportedSubscriberTypeTRAP NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
bwaVLTrapSUMacAddr,
|
|
bwaVLTrapSubscriberType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AUS only.
|
|
This trap is generated when a subscriber with unsupported type tries to associate to AUS.
|
|
The AUS supports only SU-3 and SU-6.
|
|
The first variable of the trap is the subscriber MAC Address.
|
|
The second variable is the type of subscriber"
|
|
::= { bwaVLProducts 110 }
|
|
|
|
|
|
bwaVLUnitTypeChangedTRAP NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
bwaVLTrapMACAddress,
|
|
bwaVLNewUnitTypeTrap
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to BU/RB only.
|
|
This trap is generated when the user change the type of the BWA PtP unit.
|
|
The RB can be converted in BU or vice versa.
|
|
The first variable of the trap is the unit MAC Address.
|
|
The second variable is the new type of the unit"
|
|
::= { bwaVLProducts 111 }
|
|
|
|
bwaVLWLPrioritizationNotSupportedBySUTRAP NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
bwaVLTrapSUMacAddr,
|
|
bwaVLTrapSWVersion
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable to AU/BU only.
|
|
This trap is generated when an SU/RB with a SW version below 4.0
|
|
that does not support Wireless Link Prioritization is associated
|
|
with an AU/BU with thw Wireless Link Prioritization Option enabled.
|
|
The first variable of the trap is the SU/RB MAC Address.
|
|
The second variable is the SW version of the SU/RB"
|
|
::= { bwaVLProducts 112 }
|
|
|
|
END
|