BCS-IDENT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
|
|
DisplayString FROM SNMPv2-TC
|
|
OBJECT-TYPE FROM SNMPv2-SMI
|
|
MODULE-IDENTITY FROM SNMPv2-SMI;
|
|
|
|
gi MODULE-IDENTITY
|
|
LAST-UPDATED "201008250000Z"
|
|
|
|
ORGANIZATION "Motorola Broadband Home Solutions"
|
|
CONTACT-INFO "Motorola Technical Response Center
|
|
Inside USA 1-888-944-HELP (1-888-944-4357)
|
|
Outside USA 1-215-323-0044
|
|
TRC Hours:
|
|
Monday through Friday 8am - 7pm Eastern Standard Time
|
|
Saturdays 10am - 5pm Eastern Standard Time"
|
|
|
|
DESCRIPTION "The SMIv2 MIB module for the MOTOROLA BCS common ident objects.
|
|
The MIB Tree for this is shown below."
|
|
|
|
::= {iso org(3) dod(6) internet(1) private(4) enterprises(1) 1166}
|
|
|
|
|
|
giproducts OBJECT IDENTIFIER ::= { gi 1 }
|
|
acc4000d OBJECT IDENTIFIER ::= { giproducts 1 }
|
|
anicd OBJECT IDENTIFIER ::= { giproducts 2 }
|
|
item1000 OBJECT IDENTIFIER ::= { giproducts 4 }
|
|
irt1000 OBJECT IDENTIFIER ::= { giproducts 5 }
|
|
nc1500 OBJECT IDENTIFIER ::= { giproducts 6 }
|
|
-- OM-2000 shares same OID as OM-1000
|
|
om1000 OBJECT IDENTIFIER ::= { giproducts 7 }
|
|
im1000 OBJECT IDENTIFIER ::= { giproducts 8 }
|
|
mps OBJECT IDENTIFIER ::= { giproducts 9 }
|
|
|
|
rpd1000 OBJECT IDENTIFIER ::= { giproducts 10 }
|
|
|
|
-- Access Control Processors; TSODAs and other ACPs in various products.
|
|
acpStatus OBJECT IDENTIFIER ::= { giproducts 11 }
|
|
-- Heartbeat MIB used in the Satellite environment
|
|
heartbeat OBJECT IDENTIFIER ::= { giproducts 12 }
|
|
-- Entitlement Key Common MIB - used by SDM/SEM
|
|
entitlementKey OBJECT IDENTIFIER ::= { giproducts 13 }
|
|
|
|
arpd OBJECT IDENTIFIER ::= { giproducts 14 }
|
|
svom OBJECT IDENTIFIER ::= { giproducts 15 }
|
|
svm OBJECT IDENTIFIER ::= { giproducts 16 }
|
|
erm OBJECT IDENTIFIER ::= { giproducts 17 }
|
|
|
|
-- GI SURBboard BNH
|
|
surfBbnh OBJECT IDENTIFIER ::= { giproducts 18 }
|
|
|
|
-- GI SURFboard cable modem
|
|
sb2100 OBJECT IDENTIFIER ::= { giproducts 19 }
|
|
sb2100D OBJECT IDENTIFIER ::= { giproducts 20 }
|
|
sb2000 OBJECT IDENTIFIER ::= { giproducts 21 }
|
|
|
|
-- CHS digital video headend equipment
|
|
--
|
|
saDANIS OBJECT IDENTIFIER ::= { giproducts 30 }
|
|
apex OBJECT IDENTIFIER ::= { giproducts 31 }
|
|
rem OBJECT IDENTIFIER ::= { giproducts 32 }
|
|
mpe OBJECT IDENTIFIER ::= { giproducts 33 }
|
|
spe OBJECT IDENTIFIER ::= { giproducts 34 }
|
|
ne2000 OBJECT IDENTIFIER ::= { giproducts 35 }
|
|
apex1500 OBJECT IDENTIFIER ::= { giproducts 36 }
|
|
agb OBJECT IDENTIFIER ::= { giproducts 37 }
|
|
ne2500 OBJECT IDENTIFIER ::= { giproducts 38 }
|
|
--
|
|
hdd2000 OBJECT IDENTIFIER ::= { giproducts 40 }
|
|
--
|
|
merlin OBJECT IDENTIFIER ::= { giproducts 50 }
|
|
--
|
|
rsr OBJECT IDENTIFIER ::= { giproducts 60 }
|
|
gsrm OBJECT IDENTIFIER ::= { giproducts 61 }
|
|
gom OBJECT IDENTIFIER ::= { giproducts 62 }
|
|
b3 OBJECT IDENTIFIER ::= { giproducts 63 }
|
|
adm OBJECT IDENTIFIER ::= { giproducts 64 }
|
|
|
|
-- San Diego Headend devices
|
|
|
|
sem OBJECT IDENTIFIER ::= { giproducts 70 }
|
|
ecmg OBJECT IDENTIFIER ::= { giproducts 71 }
|
|
bsiAdapter OBJECT IDENTIFIER ::= { giproducts 72 }
|
|
oles OBJECT IDENTIFIER ::= { giproducts 73 }
|
|
ne OBJECT IDENTIFIER ::= { giproducts 74 }
|
|
tmxCommTrap OBJECT IDENTIFIER ::= { giproducts 75 }
|
|
drmenginekskdc OBJECT IDENTIFIER ::= { giproducts 76 }
|
|
drmenginerte OBJECT IDENTIFIER ::= { giproducts 77 }
|
|
drmengineecmg OBJECT IDENTIFIER ::= { giproducts 78 }
|
|
drmengineskgpkg OBJECT IDENTIFIER ::= { giproducts 79 }
|
|
tmx OBJECT IDENTIFIER ::= { giproducts 80 }
|
|
prs OBJECT IDENTIFIER ::= { giproducts 81 }
|
|
se2000 OBJECT IDENTIFIER ::= { giproducts 82 }
|
|
dem OBJECT IDENTIFIER ::= { giproducts 83 }
|
|
ncs OBJECT IDENTIFIER ::= { giproducts 84 }
|
|
ucs OBJECT IDENTIFIER ::= { giproducts 85 }
|
|
lmm OBJECT IDENTIFIER ::= { giproducts 86 }
|
|
se4000 OBJECT IDENTIFIER ::= { giproducts 87 }
|
|
rc OBJECT IDENTIFIER ::= { giproducts 88 }
|
|
|
|
--
|
|
-- Element Management System Range
|
|
--
|
|
netSentry OBJECT IDENTIFIER ::= { giproducts 99 }
|
|
sdm OBJECT IDENTIFIER ::= { giproducts 100 }
|
|
hfcEms OBJECT IDENTIFIER ::= { giproducts 101 }
|
|
bnc OBJECT IDENTIFIER ::= { giproducts 102 }
|
|
drmenginecm OBJECT IDENTIFIER ::= { giproducts 103 }
|
|
stdc OBJECT IDENTIFIER ::= { giproducts 104 }
|
|
tview OBJECT IDENTIFIER ::= { giproducts 105 }
|
|
--
|
|
-- OIDS 106 thru 110 reserved for other EMS
|
|
--
|
|
--
|
|
--
|
|
-- OIDS 150 thru 225 reserved for TNS/NIS
|
|
--
|
|
ponOa OBJECT IDENTIFIER ::= { giproducts 150 }
|
|
mwtea200 OBJECT IDENTIFIER ::= { giproducts 151 }
|
|
|
|
bti OBJECT IDENTIFIER ::= { giproducts 200 }
|
|
rfModMIB OBJECT IDENTIFIER ::= { giproducts 201 }
|
|
btiIntMIB OBJECT IDENTIFIER ::= { giproducts 202 }
|
|
sg4000 OBJECT IDENTIFIER ::= { giproducts 203 }
|
|
|
|
ponEm870 OBJECT IDENTIFIER ::= { giproducts 210 }
|
|
--
|
|
-- OIDS 250 thru 290 reserved for TAS
|
|
--
|
|
rpa OBJECT IDENTIFIER ::= { giproducts 250 }
|
|
rpc OBJECT IDENTIFIER ::= { giproducts 251 }
|
|
--
|
|
-- OIDS 300 thru 310 reserved for ASTBs
|
|
--
|
|
dct5000 OBJECT IDENTIFIER ::= { giproducts 300 }
|
|
dct5100 OBJECT IDENTIFIER ::= { giproducts 301 }
|
|
dct5200 OBJECT IDENTIFIER ::= { giproducts 302 }
|
|
--
|
|
-- OIDS 314 thru 320 reserved for other CPEs
|
|
--
|
|
edfaMIB OBJECT IDENTIFIER ::= { giproducts 311 }
|
|
corvusMIB OBJECT IDENTIFIER ::= { giproducts 312 }
|
|
oa600 OBJECT IDENTIFIER ::= { giproducts 313 }
|
|
--
|
|
-- Range 321-330 reserved for DSRs
|
|
--
|
|
dsr350f OBJECT IDENTIFIER ::= { giproducts 321 }
|
|
|
|
radd6000 OBJECT IDENTIFIER ::= { giproducts 400 }
|
|
cs1000 OBJECT IDENTIFIER ::= { giproducts 401 }
|
|
kls OBJECT IDENTIFIER ::= { giproducts 402 }
|
|
dac6000 OBJECT IDENTIFIER ::= { giproducts 403 }
|
|
sdi OBJECT IDENTIFIER ::= { giproducts 404 }
|
|
cpms OBJECT IDENTIFIER ::= { giproducts 405 }
|
|
ap OBJECT IDENTIFIER ::= { giproducts 406 }
|
|
ps OBJECT IDENTIFIER ::= { giproducts 407 }
|
|
--
|
|
-- Range 350-359 reserved for Cable Cards
|
|
--
|
|
cableCard OBJECT IDENTIFIER ::= { giproducts 350 }
|
|
--
|
|
-- The following branch identifies the BCS/IPNS Devices MIB.
|
|
--
|
|
motoIPNSprodID OBJECT IDENTIFIER ::= { giproducts 450 }
|
|
--
|
|
-- Range 500-510 reserved for Simulcrypt
|
|
--
|
|
--
|
|
-- Range 600-650 reserved for IRDs
|
|
--
|
|
ird4500x OBJECT IDENTIFIER ::= { giproducts 610 }
|
|
ird4520x OBJECT IDENTIFIER ::= { giproducts 620 }
|
|
|
|
|
|
giproxies OBJECT IDENTIFIER ::= { gi 3 }
|
|
|
|
gicommon OBJECT IDENTIFIER ::= { gi 4 }
|
|
identity OBJECT IDENTIFIER ::= { gicommon 1 }
|
|
state OBJECT IDENTIFIER ::= { gicommon 2 }
|
|
traps OBJECT IDENTIFIER ::= { gicommon 3 }
|
|
logs OBJECT IDENTIFIER ::= { gicommon 4 }
|
|
--
|
|
-- nlsbbn OBJECT IDENTIFIER ::= { gi 5 }
|
|
-- added to create new path for gx2 hfc common and device mibs
|
|
motproxies OBJECT IDENTIFIER ::= { gi 6 }
|
|
|
|
--
|
|
-- The following is the SMIv2 COMMON MIB branch
|
|
--
|
|
bcs OBJECT IDENTIFIER ::= { gi 7 }
|
|
bcsIdent OBJECT IDENTIFIER ::= { bcs 1 }
|
|
-- bcsState OBJECT IDENTIFIER ::= { bcs 2 }
|
|
-- bcsTraps OBJECT IDENTIFIER ::= { bcs 3 }
|
|
bcsLogs OBJECT IDENTIFIER ::= { bcs 4 }
|
|
|
|
-- dms OBJECT IDENTIFIER ::= { bcs 5 }
|
|
--
|
|
-- New OID for SMIv2 of ACP MIB
|
|
--
|
|
-- bcs_acp OBJECT IDENTIFIER ::= { bcs 6 }
|
|
--
|
|
-- bcs OID 7 - 10 reserved for Simulcrypt
|
|
--
|
|
bcsSimulcryptScs OBJECT IDENTIFIER ::= { bcs 7 }
|
|
bcsSimulcryptMux OBJECT IDENTIFIER ::= { bcs 8 }
|
|
bcsSimulcrypt OBJECT IDENTIFIER ::= { bcs 9 }
|
|
|
|
-- bcs OID 11 - 20 reserved for common BCS infrastructure MIBs
|
|
--
|
|
bcsDatabase OBJECT IDENTIFIER ::= { bcs 11 }
|
|
bcsRedundancy OBJECT IDENTIFIER ::= { bcs 12 }
|
|
|
|
bcsMsgGeneration OBJECT IDENTIFIER ::= { bcs 21 }
|
|
--
|
|
-- Reserved for TNS
|
|
mea OBJECT IDENTIFIER ::= { gi 8 }
|
|
--
|
|
-- Reserved for common Addressable Control MIBs
|
|
addressablecontrol OBJECT IDENTIFIER ::= { gi 9 }
|
|
acCommon OBJECT IDENTIFIER ::= { addressablecontrol 1 }
|
|
acSecurity OBJECT IDENTIFIER ::= { addressablecontrol 2 }
|
|
acServices OBJECT IDENTIFIER ::= { addressablecontrol 3 }
|
|
acBsi OBJECT IDENTIFIER ::= { addressablecontrol 4 }
|
|
acOperations OBJECT IDENTIFIER ::= { addressablecontrol 5 }
|
|
acTopology OBJECT IDENTIFIER ::= { addressablecontrol 6 }
|
|
|
|
--
|
|
-- Reserved for common CHS internal MIBs
|
|
chsInternal OBJECT IDENTIFIER ::= { gi 10 }
|
|
emLogin OBJECT IDENTIFIER ::= { chsInternal 1 }
|
|
radiusClient OBJECT IDENTIFIER ::= { chsInternal 2 }
|
|
|
|
-- Need to explicitly define EntryStatus since most do not recognize
|
|
-- the version 1 format.
|
|
EntryStatus ::= INTEGER
|
|
{ valid(1),
|
|
createRequest(2),
|
|
underCreation(3),
|
|
invalid(4)
|
|
}
|
|
|
|
-- groups in the GI-IDENT MIB
|
|
|
|
-- MIB Tree
|
|
--
|
|
-- The following diagram defining the objects in this MIB is for
|
|
-- reference purposes only.
|
|
--
|
|
-- bcs
|
|
-- |
|
|
-- +..bcsIdent
|
|
-- | |
|
|
-- | +..identSerialNumber
|
|
-- | |
|
|
-- | +..identChassisNumber
|
|
-- | |
|
|
-- | +..identIfIndex
|
|
-- | |
|
|
-- | +..identHardwareVersion
|
|
-- | |
|
|
-- | +..identHardwareFeatures
|
|
-- | |
|
|
-- | +..identInventoryCode
|
|
-- | |
|
|
-- | +..identSoftwareVersion
|
|
-- | |
|
|
-- | +..identLocationArea
|
|
-- | |
|
|
-- | +..identLocationRack
|
|
-- | |
|
|
-- | +..identLocationShelf
|
|
-- | |
|
|
-- | +..identMIBVersion
|
|
-- | |
|
|
-- | +..identAgentVersion
|
|
-- | |
|
|
-- | +..identCommand
|
|
-- | |
|
|
-- | +..identIfExtensionTable
|
|
-- | | |
|
|
-- | | +..identIfExtensionEntry
|
|
-- | | |
|
|
-- | | +..identIfExtensionIndex
|
|
-- | | |
|
|
-- | | +..identIfSerialNumber
|
|
-- | | |
|
|
-- | | +..identIfHardwareVersion
|
|
-- | | |
|
|
-- | | +..identIfHardwareFeatures
|
|
-- | | |
|
|
-- | | +..identIfInventoryCode
|
|
-- | | |
|
|
-- | | +..identIfFirmwareVersion1
|
|
-- | | |
|
|
-- | | +..identIfFirmwareVersion2
|
|
-- | | |
|
|
-- | | +..identIfFirmwareVersion3
|
|
-- | | |
|
|
-- | | +..identIfFirmwareVersion4
|
|
-- | | |
|
|
-- | | +..identIfSlotId
|
|
-- | | |
|
|
-- | | +..identIfCommand
|
|
-- | | |
|
|
-- | | +..identIfAdministrativeState
|
|
-- | | |
|
|
-- | | +..identIfOperationalState
|
|
-- | | |
|
|
-- | | +..identIfAlarmStatus
|
|
-- | | |
|
|
-- | | +..identIfAvailabilityStatus
|
|
-- | | |
|
|
-- | | +..identIfSpecific
|
|
-- | | |
|
|
-- | | +..identIfEntryStatus
|
|
-- | |
|
|
-- | +..identUnitModel
|
|
|
|
|
|
|
|
-- The Identification Group.
|
|
|
|
-- This group of objects contains the identification of the software
|
|
-- and hardware for a specific unit.
|
|
|
|
identSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This contains the serial number of the unit. There is no
|
|
specification of the internal format of the serial number.
|
|
The serial number is entered into either permanent or non-
|
|
volatile memory of the unit at the time of manufacture.
|
|
Note - the unit itself supplies the serial number."
|
|
REFERENCE " -- "
|
|
::= { bcsIdent 1 }
|
|
|
|
identChassisNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This contains the chassis number of the unit. This is
|
|
applicable only to a limited number of products,
|
|
currently, only the ITEM-1000. For products for which
|
|
this is not applicable, this will be a null object.
|
|
There is no specification of the internal format of
|
|
the chassis number. The means by which any product
|
|
determines its chassis number is to be determined by
|
|
each individual product."
|
|
REFERENCE " -- "
|
|
::= { bcsIdent 2 }
|
|
|
|
|
|
identIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This contains the IfIndex of the OAM&P port."
|
|
REFERENCE " -- "
|
|
DEFVAL { 2147483647 }
|
|
::= { bcsIdent 3 }
|
|
|
|
|
|
identHardwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This contains a display string that defines the hardware
|
|
version of this particular unit. There is no specification
|
|
of the internal format of the hardware version. The
|
|
hardware version is entered into the either permanent or
|
|
non-volatile memory of the unit at the time of
|
|
manufacture."
|
|
REFERENCE " -- "
|
|
::= { bcsIdent 4 }
|
|
|
|
|
|
identHardwareFeatures OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This contains a display string that defines the features
|
|
of this particular unit. There is no specification of the
|
|
internal format of the hardware features. The hardware
|
|
features is entered into the either permanent or
|
|
non-volatile memory of the unit at the time of
|
|
manufacture."
|
|
REFERENCE " -- "
|
|
::= { bcsIdent 5 }
|
|
|
|
|
|
identInventoryCode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This contains a display string that defines the inventory
|
|
code for this unit.
|
|
Once an inventory code has been set, it should be kept in
|
|
non-volatile memory. The unit should only allow this object
|
|
to be set when it is in the 'configuration' mode. There is
|
|
no specification of the internal format of the inventory
|
|
Code."
|
|
REFERENCE " -- "
|
|
::= { bcsIdent 6 }
|
|
|
|
|
|
identSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This contains a display string that defines the current
|
|
version of the software for this unit. The format of the
|
|
software version is a fully qualified directory name. This
|
|
value is received by a unit as within a BOOTP response from
|
|
the BOOTP server. It is available to the network manager
|
|
for applications that track the installed software. Once
|
|
the software version has been set, it should be kept in
|
|
non-volatile memory."
|
|
REFERENCE " -- "
|
|
::= { bcsIdent 7 }
|
|
|
|
|
|
identLocationArea OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is different from the MIB II sysLocation variable as it
|
|
contains only the location area and does not describe the
|
|
precise location.
|
|
This contains a display string that defines the area in
|
|
which the unit is installed. Location is defined by a set
|
|
of three objects: 'Area', 'Rack', and 'Shelf'. These
|
|
location objects cannot be determined by the unit itself,
|
|
but can only be determined by the network manager. It is
|
|
available to the unit for display on a front panel. Display
|
|
of the location on the front panel is useful in validating
|
|
the configuration established by the network manager. The
|
|
unit should only allow this object to be set when it is in
|
|
the 'configuration' mode. Once the Location Area has been
|
|
set, it should be kept in non-volatile memory."
|
|
REFERENCE " -- "
|
|
::= { bcsIdent 8 }
|
|
|
|
|
|
identLocationRack OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This contains a display string that defines the rack in
|
|
which the unit is installed. Location is defined by a set
|
|
of three objects: 'Area', 'Rack', and 'Shelf'. These
|
|
location objects cannot be determined by the unit itself,
|
|
but can only be determined by the network manager. It is
|
|
available to the unit for display on a front panel. Display
|
|
of the location on the front panel is useful in validating
|
|
the configuration established by the network manager. The
|
|
unit should only allow this object to be set when it is in
|
|
the 'configuration' mode. Once the Location Area has been
|
|
set, it should be kept in non-volatile memory."
|
|
REFERENCE " -- "
|
|
::= { bcsIdent 9 }
|
|
|
|
|
|
identLocationShelf OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This contains a display string that defines the shelf in
|
|
which the unit is installed. Location is defined by a set
|
|
of three objects: 'Area', 'Rack', and 'Shelf'. These
|
|
location objects cannot be determined by the unit itself,
|
|
but can only be determined by the network manager. It is
|
|
available to the unit for display on a front panel. Display
|
|
of the location on the front panel is useful in validating
|
|
the configuration established by the network manager. The
|
|
unit should only allow this object to be set when it is in
|
|
the 'configuration' mode. Once the Location Area has been
|
|
set, it should be kept in non-volatile memory."
|
|
REFERENCE " -- "
|
|
::= { bcsIdent 10 }
|
|
|
|
|
|
|
|
identMIBVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The version number of this MIB."
|
|
REFERENCE " -- "
|
|
::= { bcsIdent 11 }
|
|
|
|
|
|
identAgentVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version number of the Agent."
|
|
REFERENCE " -- "
|
|
::= { bcsIdent 12 }
|
|
|
|
|
|
identCommand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
restart(1),
|
|
currentlyRestarting(2),
|
|
unspecified(3),
|
|
purgeAndRestart(4),
|
|
currentlyPurgingAndRestarting(5),
|
|
purgeNvramAndRestart(6),
|
|
currentlyPurgingNvramAndRestarting(7)
|
|
}
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the command to be executed by the resource
|
|
managed by the agent.
|
|
The value unspecified is always returned on SNMP
|
|
Get/GetNext while the resource is running. If the
|
|
restart(1) command is given, currentlyRestarting(2)
|
|
is returned while the resource is preparing to
|
|
restart (reboot)."
|
|
REFERENCE " -- "
|
|
::= { bcsIdent 13 }
|
|
|
|
|
|
identIfExtensionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IdentIfExtensionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains extensions to the MIB II ifTable which contains
|
|
the definitions of all interfaces. An ifTable entry may be a board
|
|
or just a port on a board. Any ifTable entry can have an extension
|
|
in the identIfExtensionTable. The corrsponding entry in that table
|
|
will have the identIfIndex = ifIndex. Within the ifTable the presence
|
|
of such an entry is indicated by setting the variable ifSpecific
|
|
to the OBJECT IDENTIFIER value of identIfExtensionTable. Otherwise
|
|
iFSpecific is set to {0 0}.
|
|
The ifType - other - is used for all board types not envisoned by
|
|
MIB II."
|
|
REFERENCE " -- "
|
|
::= { bcsIdent 14 }
|
|
|
|
|
|
identIfExtensionEntry OBJECT-TYPE
|
|
SYNTAX IdentIfExtensionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry (conceptual row) in the Board Table."
|
|
REFERENCE " -- "
|
|
INDEX { identIfExtensionIndex }
|
|
::= { identIfExtensionTable 1 }
|
|
|
|
|
|
|
|
IdentIfExtensionEntry ::= SEQUENCE
|
|
{
|
|
identIfExtensionIndex INTEGER,
|
|
identIfSerialNumber DisplayString,
|
|
identIfHardwareVersion DisplayString,
|
|
identIfHardwareFeatures DisplayString,
|
|
identIfInventoryCode DisplayString,
|
|
identIfFirmwareVersion1 DisplayString,
|
|
identIfFirmwareVersion2 DisplayString,
|
|
identIfFirmwareVersion3 DisplayString,
|
|
identIfFirmwareVersion4 DisplayString,
|
|
identIfSlotId INTEGER,
|
|
identIfCommand INTEGER,
|
|
identIfAdministrativeState INTEGER,
|
|
identIfOperationalState INTEGER,
|
|
identIfAlarmStatus INTEGER,
|
|
identIfAvailabilityStatus INTEGER,
|
|
identIfSpecific OBJECT IDENTIFIER,
|
|
identIfEntryStatus EntryStatus
|
|
}
|
|
|
|
|
|
identIfExtensionIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Same value as ifIndex of MIB II for the same board."
|
|
REFERENCE " -- "
|
|
DEFVAL { 2147483647 }
|
|
::= { identIfExtensionEntry 1 }
|
|
|
|
|
|
identIfSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This contains the serial number of the board. There is no
|
|
specification of the internal format of the serial number.
|
|
The serial number is entered into either permanent or
|
|
non-volatile memory of the unit at the time of manufacture.
|
|
Note - the unit itself supplies the serial number."
|
|
REFERENCE " -- "
|
|
::= { identIfExtensionEntry 2 }
|
|
|
|
|
|
|
|
identIfHardwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This contains a display string that defines the version
|
|
of this particular board. There is no specification of the
|
|
internal format of the hardware version. The hardware
|
|
version is entered into the either permanent or
|
|
non-volatile memory of the unit at the time of
|
|
manufacture."
|
|
REFERENCE " -- "
|
|
::= { identIfExtensionEntry 3 }
|
|
|
|
|
|
identIfHardwareFeatures OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This contains a display string that defines the features of
|
|
this particular board. There is no specification of the
|
|
internal format of the hardware features. The hardware
|
|
features is entered into the either permanent or
|
|
non-volatile memory of the unit at the time of manufacture."
|
|
REFERENCE " -- "
|
|
::= { identIfExtensionEntry 4 }
|
|
|
|
|
|
identIfInventoryCode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This contains a display string that defines the inventory
|
|
code for this board. This is an optional value; if there is
|
|
no inventory code, The unit will respond with a null string.
|
|
Once an inventory code has been set, it should be kept in
|
|
non-volatile memory. The unit should only allow this object
|
|
to be set when it is in the 'configuration' mode. There is
|
|
no specification of the internal format of the inventory
|
|
Code."
|
|
REFERENCE " -- "
|
|
::= { identIfExtensionEntry 5 }
|
|
|
|
|
|
|
|
identIfFirmwareVersion1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Within a product, there may be several identifiers of such
|
|
firmware, boot proms, kernel versions, flash versions, etc.
|
|
This field (and the 3 that follow) are used to hold the
|
|
identification of these items. These values must be entered
|
|
into the board at the time of manufacturing. Unused fields
|
|
are reported as null values. These fields are available to
|
|
the network manager for applications that keep track of the
|
|
firmware related identification. There is no specification
|
|
of the internal format of firmware version identifiers."
|
|
REFERENCE " -- "
|
|
::= { identIfExtensionEntry 6 }
|
|
|
|
|
|
identIfFirmwareVersion2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firmware related identification field # 2."
|
|
REFERENCE " -- "
|
|
::= { identIfExtensionEntry 7 }
|
|
|
|
|
|
identIfFirmwareVersion3 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firmware related identification field # 3."
|
|
REFERENCE " -- "
|
|
::= { identIfExtensionEntry 8 }
|
|
|
|
|
|
identIfFirmwareVersion4 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firmware related identification field # 4"
|
|
REFERENCE " -- "
|
|
::= { identIfExtensionEntry 9 }
|
|
|
|
|
|
identIfSlotId OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies the board slot."
|
|
REFERENCE " -- "
|
|
DEFVAL { 2147483647 }
|
|
::= { identIfExtensionEntry 10 }
|
|
|
|
|
|
identIfCommand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unspecified(1),
|
|
reset(2),
|
|
restart(3),
|
|
halt(4)
|
|
}
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the command to be executed by the resource
|
|
managed by the agent.
|
|
The value unspecified(10 is always returned on SNMP
|
|
Get/GetNext while the other values are set by the manager
|
|
and executed by the resource."
|
|
REFERENCE " -- "
|
|
::= { identIfExtensionEntry 11 }
|
|
|
|
|
|
identIfAdministrativeState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
locked(1),
|
|
unlocked(2),
|
|
shuttingDown(3)
|
|
}
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The current Adminsitrative state of the interface as defined in
|
|
ISO/IEC 10164-2."
|
|
REFERENCE " -- "
|
|
::= { identIfExtensionEntry 12 }
|
|
|
|
|
|
identIfOperationalState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The current Operational state of the interface as defined in
|
|
ISO/IEC 10164-2"
|
|
REFERENCE " -- "
|
|
::= { identIfExtensionEntry 13 }
|
|
|
|
|
|
identIfAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
underRepair(1),
|
|
critical(2),
|
|
major(3),
|
|
minor(4),
|
|
alarmOutstanding(5),
|
|
idle(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This object defines the Alarm status of the interface
|
|
as defined in ISO/IEC 10164-2 and state-machine"
|
|
REFERENCE " -- "
|
|
::= { identIfExtensionEntry 14 }
|
|
|
|
|
|
identIfAvailabilityStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
inTest(1),
|
|
failed(2),
|
|
powerOff(3),
|
|
offLine(4),
|
|
offDuty(5),
|
|
dependency(6),
|
|
degraded(7),
|
|
notInstalled(8),
|
|
logFull(9),
|
|
available(10)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This object controls the Availability status of the interface
|
|
as defined in ISO/IEC 10164-2 and state-machine"
|
|
REFERENCE " -- "
|
|
::= { identIfExtensionEntry 15 }
|
|
|
|
|
|
identIfSpecific OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The object identifier of a board type specific
|
|
extension to the ifTable if necessary. Otherwise,
|
|
identIfSpecific is set to {0 0}."
|
|
REFERENCE " -- "
|
|
::= { identIfExtensionEntry 16 }
|
|
|
|
|
|
identIfEntryStatus OBJECT-TYPE
|
|
SYNTAX EntryStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to create, delete or
|
|
modify a row in this table. To create a
|
|
a new network element, this object is initially
|
|
set to 'createRequest'. After completion of the
|
|
configuration of the new entry, the manager
|
|
must set the appropriate instance of this object
|
|
to the value valid(1) or aborts, setting this object
|
|
to invalid(4). This object must not be set to
|
|
'active' unless the following columnar objects
|
|
exist in this row:
|
|
identIfExtensionIndex
|
|
identIfSerialNumber
|
|
identIfHardwareVersion
|
|
identIfInventoryCode
|
|
identIfFirmwareVersion1
|
|
identIfSpecific
|
|
To delete an existing entry in this table,
|
|
the manager must set the appropriate
|
|
instance of this object to the value invalid(4).
|
|
Creation of an instance of this object has the
|
|
effect of creating the supplemental object instances
|
|
to complete the conceptual row. An existing instance
|
|
of this entry cannot be created. If circumstances
|
|
occur which cause an entry to become invalid, the
|
|
agent modifies the value of the appropriate instance
|
|
of this object to invalid(4). Whenever, the value of
|
|
this object for a particular entry becomes
|
|
invalid(4), the conceptual row for that instance may
|
|
be removed from the table at any time, either
|
|
immediately or subsequently."
|
|
DEFVAL { valid }
|
|
::= { identIfExtensionEntry 17 }
|
|
|
|
|
|
|
|
identUnitModel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This contains the model of the product. For example,
|
|
the ITEM-1000 would contain 'ITEM1000'. "
|
|
REFERENCE " -- "
|
|
::= { bcsIdent 15 }
|
|
|
|
|
|
|
|
|
|
END |