AC-ANALOG-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE,
MODULE-IDENTITY FROM SNMPv2-SMI
TAddress,
DisplayString,
DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC
IpAddress FROM RFC1155-SMI
Unsigned32,
Integer32,
enterprises FROM SNMPv2-SMI
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
audioCodes,
acRegistrations,
acGeneric,
acProducts,acBoardMibs FROM AUDIOCODES-TYPES-MIB;
acAnalog MODULE-IDENTITY
LAST-UPDATED "201207260446Z" --Thursday, July 26 2012
ORGANIZATION "AudioCodes Ltd"
CONTACT-INFO
"Postal: Support
AudioCodes LTD
1 Hayarden Street
Airport City
Lod, ISRAEL 70151
Tel: 972-3-9764000
Fax: 972-3-9764040
Email: support@audiocodes.com
Web: www.audiocodes.com"
DESCRIPTION
""
::= {acBoardMibs 8}
acAnalogConfiguration OBJECT IDENTIFIER ::= {acAnalog 1}
acAnalogConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 1}
acAnalogMisc OBJECT IDENTIFIER ::= {acAnalogConfig 1}
acAnalogMiscCurrentDisconnectDuration OBJECT-TYPE
SYNTAX Unsigned32 (200..1500)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the current-disconnect duration (in msec). This value
is used in generation and detection.
Access: Offline.
AC INI-Param: CurrentDisconnectDuration"
::= {acAnalogMisc 1}
acAnalogMiscFlashHookPeriod OBJECT-TYPE
SYNTAX Unsigned32 (25..3000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the flashhook period (in msec) for both analog and IP
sides.
For the analog side it defines:
- The maximal hook-flash detection period (for FXS gateways).
A longer signal is considered offhook / onhook event.
- The hook-flash generation period (for FXO gateways).
For the IP side it defines the flash-hook period that is reported
to IP.
The valid range is 25 to 1500. The default value is 700 msec.
Note: For FXO gateways, a constant of 90 msec must be added
to the required hook-flash period. For example, to generate
a 450 msec hook-flash, set <20>FlashHookPeriod<6F> to 540.
.
Access: Instant.
AC INI-Param: FLASHHOOKPERIOD"
::= {acAnalogMisc 2}
acAnalogMiscGroundKeyDetection OBJECT-TYPE
SYNTAX INTEGER {
disable(0)
,
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/disables the analog ground key detection.
0 = Disable
1= Enable.
Access: Offline.
AC INI-Param: GroundKeyDetection"
::= {acAnalogMisc 3}
acAuxiliaryFiles OBJECT IDENTIFIER ::= {acAnalogConfig 2}
acAuxiliaryFilesFxsCoefficients OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..47))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defines the FXS loop coefficient filename.
Max. 47 characters.
AC INI-Param: FXSCOEFFILENAME"
::= {acAuxiliaryFiles 1}
acAuxiliaryFilesFxoCoefficients OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..47))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defines the FXO loop coefficient filename.
Max. 47 characters.
AC INI-Param: FXOCOEFFILENAME"
::= {acAuxiliaryFiles 2}
acAnalogFxoConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 2}
acAnalogFxo OBJECT IDENTIFIER ::= {acAnalogFxoConfig 1}
acAnalogFxoFarEndDisconnectType OBJECT-TYPE
SYNTAX Unsigned32 (0..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter sets the source for the acEV_FAR_END_DISCONNECTED
event (or for the relevant control protocol event). It
is a bit field parameter, hence (for example) if both CPT and
current disconnect are required, the parameter should be set
to 5.
FarDisconnect contributor:
1 = CPT
2 = PolarityReversal
4 = CurrentDisconnect
8 = Silence.
Access: Offline.
AC INI-Param: FARENDDISCONNECTTYPE"
::= {acAnalogFxo 1}
acAnalogFxoCountryCoefficients OBJECT-TYPE
SYNTAX INTEGER {
europe(66)
,
unitedStates(70)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allows the user to modify the line characteristic (AC and DC)
according to country.
Access: Offline.
AC INI-Param: CountryCoefficients"
::= {acAnalogFxo 2}
acAnalogFxoDCRemover OBJECT-TYPE
SYNTAX INTEGER {
disable(0)
,
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines whether to enable the analog DC remover in the DAA.
One of the following values:
0 = DC remover is disabled
1 = DC remover is enabled.
Access: Offline.
AC INI-Param: EnableAnalogDCRemover"
::= {acAnalogFxo 3}
acAnalogFxoDefaultLinePolarityState OBJECT-TYPE
SYNTAX INTEGER {
positive-polarity(0)
,
negative-polarity(1)
,
polarity-auto-detect(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the TTX pulses voltage level.
0 = 0Vrms sinusoidal bursts
1 = 0.5Vrms sinusoidal bursts
2 = 1Vrms sinusoidal bursts.
Access: Offline.
AC INI-Param: SetDefaultLinePolarityState"
::= {acAnalogFxo 4}
acAnalogFxoTxGainControl OBJECT-TYPE
SYNTAX Integer32 (-15..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets gain\attenuation of the FXO Tx path between -15db and 12db.
default no gain.
Access: Offline.
AC INI-Param: FXOTxGainControl"
::= {acAnalogFxo 5}
acAnalogFxoRxGainControl OBJECT-TYPE
SYNTAX Integer32 (-15..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets gain\attenuation of the FXO Rx path between -15db and 12db.
default no gain.
Access: Offline.
AC INI-Param: FXORxGainControl"
::= {acAnalogFxo 6}
-- ****************************************
-- acAnalogFxoFarEndDisconnectTone table declaration
-- ****************************************
acAnalogFxoFarEndDisconnectToneTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcAnalogFxoFarEndDisconnectToneEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= {acAnalogFxo 21}
-- ****************************************
-- acAnalogFxoFarEndDisconnectTone table entry
-- ****************************************
acAnalogFxoFarEndDisconnectToneEntry OBJECT-TYPE
SYNTAX AcAnalogFxoFarEndDisconnectToneEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acAnalogFxoFarEndDisconnectToneIndex}
::= {acAnalogFxoFarEndDisconnectToneTable 1}
-- ****************************************
-- acAnalogFxoFarEndDisconnectTone TABLE
-- ****************************************
AcAnalogFxoFarEndDisconnectToneEntry ::= SEQUENCE {
acAnalogFxoFarEndDisconnectToneRowStatus Unsigned32,
acAnalogFxoFarEndDisconnectToneAction Unsigned32,
acAnalogFxoFarEndDisconnectToneActionResult Unsigned32,
acAnalogFxoFarEndDisconnectToneIndex Unsigned32,
acAnalogFxoFarEndDisconnectToneType INTEGER
}
acAnalogFxoFarEndDisconnectToneRowStatus OBJECT-TYPE
SYNTAX Unsigned32 (1..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Far End Disconnect table row-status.
AC INI-Param: N/A"
::= {acAnalogFxoFarEndDisconnectToneEntry 1}
acAnalogFxoFarEndDisconnectToneAction OBJECT-TYPE
SYNTAX Unsigned32 (0..0)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Far End Disconnect table action.
AC INI-Param: N/A"
::= {acAnalogFxoFarEndDisconnectToneEntry 2}
acAnalogFxoFarEndDisconnectToneActionResult OBJECT-TYPE
SYNTAX Unsigned32 (0..0)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Far End Disconnect table result.
AC INI-Param: N/A"
::= {acAnalogFxoFarEndDisconnectToneEntry 3}
acAnalogFxoFarEndDisconnectToneIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for table use.
AC INI-Param: N/A"
::= {acAnalogFxoFarEndDisconnectToneEntry 4}
acAnalogFxoFarEndDisconnectToneType OBJECT-TYPE
SYNTAX INTEGER {
acNullTone(0)
,
acDialTone(1)
,
acRingingTone(2)
,
acBusyTone(3)
,
acCongestionTone(4)
,
acSpecialInfoTone(5)
,
acWarningTone(6)
,
acReorderTone(7)
,
acConfirmationTone(8)
,
acWaitingTone(9)
,
acCallProgressCo1Tone(10)
,
acCallProgressCo2Tone(11)
,
acOldMilliwattTone(12)
,
acNewMilliwattTone(13)
,
acMessageWaitingIndicator(14)
,
acStutterDialTone(15)
,
acStutterOffHookWarningTone(16)
,
acWaitingTone1(17)
,
acComfortTone(18)
,
acNAKTone(19)
,
acVacantNumberTone(20)
,
acSpecialConditionTone(21)
,
acDialTone2(22)
,
acOnHoldTone(23)
,
acCallTransferDialTone(24)
,
acCallForwardTone(25)
,
acCreditCardServiceTone(26)
,
acSpecialRecallDialTone(27)
,
acAlertingTone(28)
,
acNetworkCongestionTone(29)
,
acWaitingTone2(30)
,
acWaitingTone3(31)
,
acWaitingTone4(32)
,
acConfEnterTone(33)
,
acConfExitTone(34)
,
acConfLockTone(35)
,
acConfUnlockTone(36)
,
acConfTimeLimitTone(37)
,
acPayphoneRecognitionTone(38)
,
acCallerWaitingTone(39)
,
acCNGFaxTone(40)
,
acPrecConfNotifyType(41)
,
acPresConfNotifyType(42)
,
acPrecPreemptType(43)
,
acPrecRTType(44)
,
acR15reqOfANItone(45)
,
acCo1Tone(200)
,
acCo2Tone(201)
,
acPlayRecordBeepTone(202)
,
acTrunkTestingTestProgressTone(203)
,
acTrunkTestingTestTone(204)
,
acTrunkTestingGuardTone(205)
,
acFSKTrunkTestingTone(206)
,
acGeneralTrunkTestingTone1(207)
,
acGeneralTrunkTestingTone2(208)
,
acGeneralTrunkTestingTone3(209)
,
acSpecialInfoToneFirst(210)
,
acSpecialInfoToneSecond(211)
,
acSpecialInfoToneThird(212)
,
acTTYTone(213)
,
acTT904ContinuityTone(214)
,
acTTMilliwattLossMeasureTone(215)
,
acCarrierDialTone(216)
,
acCarrierAnswerTone(217)
,
acCarrierChargingTone(218)
,
acLongDistanceIndicatorTone(219)
,
acSTUModemFirstTone(298)
,
acSTUModemSecondTone(299)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines which CPT types are detected as far-end disconnect.
The CPT type is based on the acTCallProgressToneType enum.
This is valid when FarEndDisconnectType allows CPT detection.
Range = An array of up to 4 tone types.
Access: Offline.
AC INI-Param: DISCONNECTTONETYPE"
::= {acAnalogFxoFarEndDisconnectToneEntry 5}
acAnalogFxsConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 3}
acAnalogFxs OBJECT IDENTIFIER ::= {acAnalogFxsConfig 1}
acAnalogFxsPolarityReversalType OBJECT-TYPE
SYNTAX INTEGER {
soft(0)
,
hard(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the type of the polarity reversal signal used for the network
far-end answer and disconnect indications. Smooth reversal
prevents negative effects as non-required ringing.
0 = Soft reverse polarity
1 = Hard reverse polarity.
Access: Offline.
AC INI-Param: POLARITYREVERSALTYPE"
::= {acAnalogFxs 1}
acAnalogFxsMeteringType OBJECT-TYPE
SYNTAX INTEGER {
mt12kHz(0)
,
mt16kHz(1)
,
mtPolarityReversal(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the metering method for charging pulses.
0 = 12 kHz sinusoidal bursts
1 = 16 kHz sinusoidal bursts
2 = Polarity Reversal pulses.
Access: Offline.
AC INI-Param: METERINGTYPE"
::= {acAnalogFxs 2}
acAnalogFxsLifeLineType OBJECT-TYPE
SYNTAX INTEGER {
acLifeLineType-Hardware-Only(0)
,
acLifeLineTypeHardware-And-Link-Detection(1)
,
acLifeLineType-Hardware-And-Link-And-Network-Detection(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the Lifeline phone type. The Lifeline phone is available
(for FXS only) on port 4 in MP-104 and MP-108, on port
2 in MP-102, on ports 1-4 in the MP-118, and on port 2 of each
analog module in the Mediant 1000.
0 = activate Lifeline phone on power down
1 = activate Lifeline phone on power down or on detection of
LAN disconnect
2 = activate Lifeline phone on power down, or on detection
of LAN disconnect, or on loss of ping.
Access: Offline.
AC INI-Param: LIFELINETYPE"
::= {acAnalogFxs 3}
acAnalogFxsMinFlashHookTime OBJECT-TYPE
SYNTAX Unsigned32 (25..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the minimal time (in msec) for detection of a flash-hook
event (for FXS only). The valid range is 25 to 300. The default
value is 300 msec.
Detection is guaranteed for flash hook periods of at least
60 msec (when setting the minimal time to 25). Flash-hook signals
that last a shorter period of time are ignored.
Note: It is recommended to reduce the detection time by 50
msec from the desired value (e.g. if you set the value as 200
msec, then enter 150 msec, i.e. 200 minus 50).
.
Access: Offline.
AC INI-Param: MINFLASHHOOKTIME"
::= {acAnalogFxs 4}
acAnalogFxsCallerIDTimingMode OBJECT-TYPE
SYNTAX INTEGER {
disable(0)
,
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the Analog CallerID Timing Mode.
0 = CallerID transferred between first and second rings
1 = CallerID transferred on valid Off ring.
Access: Offline.
AC INI-Param: ANALOGCALLERIDTIMINGMODE"
::= {acAnalogFxs 5}
acAnalogFxsBellcoreCallerIDTypeOneSubStandard OBJECT-TYPE
SYNTAX INTEGER {
bellcore-Between-Rings(0)
,
bellcore-Not-Ring-Related(1)
,
bellcore-Before-Ring-RP-AS(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the sub-standard of the Bellcore Caller ID type.
0 = Between_Rings
1 = Not_Ring_Related
2 = Before_Ring_RP_AS.
Access: Offline.
AC INI-Param: BellcoreCallerIDTypeOneSubStandard"
::= {acAnalogFxs 6}
acAnalogFxsETSICallerIDTypeOneSubStandard OBJECT-TYPE
SYNTAX INTEGER {
eTSI-Between-Rings(0)
,
eTSI-Before-Ring-DT-AS(1)
,
eTSI-Before-Ring-RP-AS(2)
,
eTSI-Before-Ring-LR-DT-AS(3)
,
eTSI-Not-Ring-Related-DT-AS(4)
,
eTSI-Not-Ring-Related-RP-AS(5)
,
eTSI-Not-Ring-Related-LR-DT-AS(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the number denoting the ETSI CallerID Type 1 sub-standard.
Either:
0 = ETSI_Between_Rings
1 = ETSI_Before_Ring_DT_AS
2 = ETSI_Before_Ring_RP_AS
3 = ETSI_Before_Ring_LR_DT_AS
4 = ETSI_Not_Ring_Related_DT_AS
5 = ETSI_Not_Ring_Related_RP_AS
6 = ETSI_Not_Ring_Related_LR_DT_AS.
Access: Offline.
AC INI-Param: ETSICallerIDTypeOneSubStandard"
::= {acAnalogFxs 7}
acAnalogFxsETSIVMWITypeOneStandard OBJECT-TYPE
SYNTAX INTEGER {
eTSI-VMWI-Between-Rings(0)
,
eTSI-VMWI-Before-Ring-DT-AS(1)
,
eTSI-VMWI-Before-Ring-RP-AS(2)
,
eTSI-VMWI-Before-Ring-LR-DT-AS(3)
,
eTSI-VMWI-Not-Ring-Related-DT-AS(4)
,
eTSI-VMWI-Not-Ring-Related-RP-AS(5)
,
eTSI-VMWI-Not-Ring-Related-LR-DT-AS(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the number denoting the ETSI VMWI Type 1 Standard.
Choose:
0 = ETSI_VMWI_Between_Rings
1 = ETSI_VMWI_Before_Ring_DT_AS
2 = ETSI_VMWI_Before_Ring_RP_AS
3 = ETSI_VMWI_Before_Ring_LR_DT_AS
4 = ETSI_VMWI_Not_Ring_Related_DT_AS
5 = ETSI_VMWI_Not_Ring_Related_RP_AS
6 = ETSI_VMWI_Not_Ring_Related_LR_DT_AS.
Access: Offline.
AC INI-Param: ETSIVMWITypeOneStandard"
::= {acAnalogFxs 8}
acAnalogFxsBellcoreVMWITypeOneStandard OBJECT-TYPE
SYNTAX INTEGER {
bellcore-VMWI-Between-Rings(0)
,
bellcore-VMWI-Not-Ring-Related(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Use this parameter to select the Bellcore VMWI standard.
0 - Between_Rings
1 - Not_Ring_Related.
Access: Offline.
AC INI-Param: BellcoreVMWITypeOneStandard"
::= {acAnalogFxs 9}
acAnalogFxsDisableAutoCalibration OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines whether to enable the analog Autocalibration in the
DAA.
One of the following values:
0 = Auto calibration is enabled
1 = Auto calibration is disabled.
Access: Offline.
AC INI-Param: DisableAnalogAutoCalibration"
::= {acAnalogFxs 10}
acAnalogFxsExternalLifeLinePorts OBJECT-TYPE
SYNTAX Unsigned32 (0..24)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the amount of FXS ports which will be connected to an external
life line and will be disabled (max value is half of
the FXS ports).
Access: Offline.
AC INI-Param: ExternalLifeLinePorts"
::= {acAnalogFxs 11}
acAnalogFxsCountryCoefficients OBJECT-TYPE
SYNTAX INTEGER {
europe(66)
,
unitedStates(70)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allows the user to modify the line characteristic (AC and DC)
according to country.
Access: Offline.
AC INI-Param: FXSCountryCoefficients"
::= {acAnalogFxs 12}
acAnalogFxsTTXVoltageLevel OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(-1)
,
ttxVoltageLevel0V(0)
,
ttxVoltageLevel05(1)
,
ttxVoltageLevel1V(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the TTX pulses voltage level.
0 = 0Vrms sinusoidal bursts
1 = 0.5Vrms sinusoidal bursts
2 = 1Vrms sinusoidal bursts
-1 = notAvailable.
Access: Offline.
AC INI-Param: AnalogTTXVoltageLevel"
::= {acAnalogFxs 13}
acAnalogEMConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 4}
acAnalogEM OBJECT IDENTIFIER ::= {acAnalogEMConfig 1}
acAnalogEMVoiceType OBJECT-TYPE
SYNTAX INTEGER {
twoWire(0)
,
fourWire(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"E&M Voice Configuration Type 2 or 4 wire.
Access: Offline.
AC INI-Param: EnMVoiceType"
::= {acAnalogEM 1}
acAnalogEMInterfaceType OBJECT-TYPE
SYNTAX INTEGER {
signaling(0)
,
trunking(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"E&M Signaling Type - Trunking or Signaling.
Access: Offline.
AC INI-Param: EnMSystemType"
::= {acAnalogEM 2}
acAnalogEMSignalingType OBJECT-TYPE
SYNTAX Unsigned32 (1..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set E&M standatd signaling types are described in TIA/EIA-464C.
Access: Offline.
AC INI-Param: EnMSignalingType"
::= {acAnalogEM 3}
acAnalogEMPortRXGain OBJECT-TYPE
SYNTAX INTEGER {
disable(0)
,
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Rx Gain.
Access: Offline.
AC INI-Param: EnMPortRXGain"
::= {acAnalogEM 4}
acAnalogEMPortTXGain OBJECT-TYPE
SYNTAX INTEGER {
disable(0)
,
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tx Gain.
Access: Offline.
AC INI-Param: EnMPortTXGain"
::= {acAnalogEM 5}
acAnalogEMCountryCoefficients OBJECT-TYPE
SYNTAX INTEGER {
unitedStates(0)
,
europe(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"E&M Country Coefficients.
Access: Offline.
AC INI-Param: EnMCountryCoefficients"
::= {acAnalogEM 6}
acAnalogEMHookDebounceTiming OBJECT-TYPE
SYNTAX Unsigned32 (30..150)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the on E&M hook detection debounce timing.
Access: Offline.
AC INI-Param: EnMhookDebounceTiming"
::= {acAnalogEM 7}
acAnalogEMOffHookGlareEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(0)
,
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Protect the EnM port from Rx and Tx hook collision.
Access: Offline.
AC INI-Param: EnMOffHookGlareEnable"
::= {acAnalogEM 8}
acAnalogStatus OBJECT IDENTIFIER ::= {acAnalog 2}
acAnalogStatusMisc OBJECT IDENTIFIER ::= {acAnalogStatus 1}
acAnalogStatusMiscFxsOrFxo OBJECT-TYPE
SYNTAX INTEGER {
fXO(0)
,
fXS(1)
,
eANDm(2)
,
fXOandFXS(3)
,
fXOandFXSandEM(5)
,
fXOandEM(6)
,
fXSandEM(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Board is Fxs,Fxo, FXS_FXO or E&M.
AC INI-Param: N/A"
::= {acAnalogStatusMisc 1}
acAnalogStatusMiscBoardTemperature OBJECT-TYPE
SYNTAX Unsigned32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature of the board in degrees Celsius, should not go higher
then 60!.
AC INI-Param: N/A"
::= {acAnalogStatusMisc 2}
acAnalogStatusMiscAnalogChannelsCount OBJECT-TYPE
SYNTAX Unsigned32 (0..5000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of the Analog channels in the board.
AC INI-Param: N/A"
::= {acAnalogStatusMisc 3}
acAnalogFxsFxo OBJECT IDENTIFIER ::= {acAnalogStatus 20}
-- ****************************************
-- acAnalogFxsFxo table declaration
-- ****************************************
acAnalogFxsFxoTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcAnalogFxsFxoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= {acAnalogFxsFxo 1}
-- ****************************************
-- acAnalogFxsFxo table entry
-- ****************************************
acAnalogFxsFxoEntry OBJECT-TYPE
SYNTAX AcAnalogFxsFxoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acAnalogFxsFxoIndex}
::= {acAnalogFxsFxoTable 1}
-- ****************************************
-- acAnalogFxsFxo TABLE
-- ****************************************
AcAnalogFxsFxoEntry ::= SEQUENCE {
acAnalogFxsFxoIndex Unsigned32,
acAnalogFxsFxoType INTEGER,
acAnalogFxsFxoChipRevNum Unsigned32,
acAnalogFxsFxoHookState INTEGER
}
acAnalogFxsFxoIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..24)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index for table use.
AC INI-Param: N/A"
::= {acAnalogFxsFxoEntry 1}
acAnalogFxsFxoType OBJECT-TYPE
SYNTAX INTEGER {
fXO(0)
,
fXS(1)
,
eM(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line is Fxs, Fxo or E&M.
AC INI-Param: N/A"
::= {acAnalogFxsFxoEntry 2}
acAnalogFxsFxoChipRevNum OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fxs/Fxo's Chip revision number.
AC INI-Param: N/A"
::= {acAnalogFxsFxoEntry 3}
acAnalogFxsFxoHookState OBJECT-TYPE
SYNTAX INTEGER {
onHookState(1)
,
offHookState(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The hook state of the analog line.
AC INI-Param: N/A"
::= {acAnalogFxsFxoEntry 4}
acAnalogAction OBJECT IDENTIFIER ::= {acAnalog 3}
acAnalogFxoAction OBJECT IDENTIFIER ::= {acAnalogAction 1}
-- ****************************************
-- acAnalogFxoLineTest table declaration
-- ****************************************
acAnalogFxoLineTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcAnalogFxoLineTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= {acAnalogFxoAction 1}
-- ****************************************
-- acAnalogFxoLineTest table entry
-- ****************************************
acAnalogFxoLineTestEntry OBJECT-TYPE
SYNTAX AcAnalogFxoLineTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acAnalogFxoLineTestIndex}
::= {acAnalogFxoLineTestTable 1}
-- ****************************************
-- acAnalogFxoLineTest TABLE
-- ****************************************
AcAnalogFxoLineTestEntry ::= SEQUENCE {
acAnalogFxoLineTestIndex Unsigned32,
acAnalogFxoLineTestActivate INTEGER,
acAnalogFxoLineTestHookState INTEGER,
acAnalogFxoLineTestPolarityStatus INTEGER,
acAnalogFxoLineTestLineConnectionStatus INTEGER,
acAnalogFxoLineTestLineCurrent Integer32,
acAnalogFxoLineTestLineVoltage Integer32,
acAnalogFxoLineTestRingState INTEGER,
acAnalogFxoLineTestLinePolarity INTEGER,
acAnalogFxoLineTestMwiState INTEGER,
acAnalogFxoLineTestLastCurrentDisconnectDuration
Unsigned32
}
acAnalogFxoLineTestIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..24)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index for table use.
AC INI-Param: N/A"
::= {acAnalogFxoLineTestEntry 1}
acAnalogFxoLineTestActivate OBJECT-TYPE
SYNTAX INTEGER {
noTestActivated(0)
,
runLineTest(1)
,
lineTestDone(2)
,
testFailed(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Activate line testing in an FXO analog line according to a given
line-index.
AC INI-Param: N/A"
::= {acAnalogFxoLineTestEntry 2}
acAnalogFxoLineTestHookState OBJECT-TYPE
SYNTAX INTEGER {
onHookState(1)
,
offHookState(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The hook state of the analog line.
AC INI-Param: N/A"
::= {acAnalogFxoLineTestEntry 3}
acAnalogFxoLineTestPolarityStatus OBJECT-TYPE
SYNTAX INTEGER {
normalPolarity(1)
,
reversePolarity(2)
,
notAvailable(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The line's polarity state.
AC INI-Param: N/A"
::= {acAnalogFxoLineTestEntry 4}
acAnalogFxoLineTestLineConnectionStatus OBJECT-TYPE
SYNTAX INTEGER {
lineDisconnected(1)
,
lineConnected(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The connection's status of the line.
AC INI-Param: N/A"
::= {acAnalogFxoLineTestEntry 5}
acAnalogFxoLineTestLineCurrent OBJECT-TYPE
SYNTAX Integer32 (-1..24)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The line's current [ma].
AC INI-Param: N/A"
::= {acAnalogFxoLineTestEntry 6}
acAnalogFxoLineTestLineVoltage OBJECT-TYPE
SYNTAX Integer32 (-128..128)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The line's voltage [V].
AC INI-Param: N/A"
::= {acAnalogFxoLineTestEntry 7}
acAnalogFxoLineTestRingState OBJECT-TYPE
SYNTAX INTEGER {
off(1)
,
on(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Ring's State.
AC INI-Param: N/A"
::= {acAnalogFxoLineTestEntry 8}
acAnalogFxoLineTestLinePolarity OBJECT-TYPE
SYNTAX INTEGER {
positive(1)
,
negative(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The line's polarity state.
AC INI-Param: N/A"
::= {acAnalogFxoLineTestEntry 9}
acAnalogFxoLineTestMwiState OBJECT-TYPE
SYNTAX INTEGER {
off(1)
,
on(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mwi's state.
AC INI-Param: N/A"
::= {acAnalogFxoLineTestEntry 10}
acAnalogFxoLineTestLastCurrentDisconnectDuration OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last current disconnect duration in msec.
AC INI-Param: N/A"
::= {acAnalogFxoLineTestEntry 11}
acAnalogFxsAction OBJECT IDENTIFIER ::= {acAnalogAction 2}
-- ****************************************
-- acAnalogFxsLineTest table declaration
-- ****************************************
acAnalogFxsLineTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcAnalogFxsLineTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= {acAnalogFxsAction 1}
-- ****************************************
-- acAnalogFxsLineTest table entry
-- ****************************************
acAnalogFxsLineTestEntry OBJECT-TYPE
SYNTAX AcAnalogFxsLineTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acAnalogFxsLineTestIndex}
::= {acAnalogFxsLineTestTable 1}
-- ****************************************
-- acAnalogFxsLineTest TABLE
-- ****************************************
AcAnalogFxsLineTestEntry ::= SEQUENCE {
acAnalogFxsLineTestIndex Unsigned32,
acAnalogFxsLineTestActivate INTEGER,
acAnalogFxsLineTestHookState INTEGER,
acAnalogFxsLineTestRingState INTEGER,
acAnalogFxsLineTestPolarityStatus INTEGER,
acAnalogFxsLineTestMessageWaitingIndication INTEGER,
acAnalogFxsLineTestLineCurrentReading Unsigned32,
acAnalogFxsLineTestLineVoltageReading Integer32,
acAnalogFxsLineTestAnalogVoltageReading Unsigned32,
acAnalogFxsLineTestRingVoltageReading Integer32,
acAnalogFxsLineTestLongLineCurrentReading Unsigned32
}
acAnalogFxsLineTestIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..24)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index for table use.
AC INI-Param: N/A"
::= {acAnalogFxsLineTestEntry 1}
acAnalogFxsLineTestActivate OBJECT-TYPE
SYNTAX INTEGER {
noTestActivated(0)
,
runLineTest(1)
,
lineTestDone(2)
,
testFailed(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Activate line testing in a FXS analog line according to a given
line-index.
AC INI-Param: N/A"
::= {acAnalogFxsLineTestEntry 2}
acAnalogFxsLineTestHookState OBJECT-TYPE
SYNTAX INTEGER {
onHookState(1)
,
offHookState(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The hook state of the analog line.
AC INI-Param: N/A"
::= {acAnalogFxsLineTestEntry 3}
acAnalogFxsLineTestRingState OBJECT-TYPE
SYNTAX INTEGER {
offRingState(1)
,
onRingState(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line's ring state.
AC INI-Param: N/A"
::= {acAnalogFxsLineTestEntry 4}
acAnalogFxsLineTestPolarityStatus OBJECT-TYPE
SYNTAX INTEGER {
normalPolarity(1)
,
reversePolarity(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line's reversal-polarity.
AC INI-Param: N/A"
::= {acAnalogFxsLineTestEntry 5}
acAnalogFxsLineTestMessageWaitingIndication OBJECT-TYPE
SYNTAX INTEGER {
noWaitingMessage(1)
,
waitingMessage(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line's messgae waiting indication state.
AC INI-Param: N/A"
::= {acAnalogFxsLineTestEntry 6}
acAnalogFxsLineTestLineCurrentReading OBJECT-TYPE
SYNTAX Unsigned32 (0..3000)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The Line current reading in 10ua units.
This test is supported only in line no. 0.
Not supported on MP500.
In case of MP124 this test is supported in all ports except
ports 2 and 3.
As of version 6.6 this is an obsolete parameter.
AC INI-Param: N/A"
::= {acAnalogFxsLineTestEntry 7}
acAnalogFxsLineTestLineVoltageReading OBJECT-TYPE
SYNTAX Integer32 (-6000..6000)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The Line voltage reading in 10mV units.
In case of MP124 the Line voltage reading in 1V units.
This test is supported only in line no. 0.
Not supported on MP500.
In case of MP124 this test is supported in all ports except
ports 2 and 3.
As of version 6.6 this is an obsolete parameter.
AC INI-Param: N/A"
::= {acAnalogFxsLineTestEntry 8}
acAnalogFxsLineTestAnalogVoltageReading OBJECT-TYPE
SYNTAX Unsigned32 (300..340)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The current analog voltage reading in 10mV units.
his test is supported only in line no. 0.
Not supported on MP500.
In case of MP124 this test is supported in all ports except
ports 2 and 3.
As of version 6.6 this is an obsolete parameter.
AC INI-Param: N/A"
::= {acAnalogFxsLineTestEntry 9}
acAnalogFxsLineTestRingVoltageReading OBJECT-TYPE
SYNTAX Integer32 (-13000..13000)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The current ring voltage reading in 10mV units.
This test is supported only in line no. 0.
Not supported on MP500.
In case of MP124 this test is supported in all ports except
ports 2 and 3.
As of version 6.6 this is an obsolete parameter.
AC INI-Param: N/A"
::= {acAnalogFxsLineTestEntry 10}
acAnalogFxsLineTestLongLineCurrentReading OBJECT-TYPE
SYNTAX Unsigned32 (0..4000)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The current long line reading in 10ua units.
This test is supported only in line no. 0.
Not supported on MP500.
In case of MP124 this test is supported in all ports except
ports 2 and 3.
As of version 6.6 this is an obsolete parameter.
AC INI-Param: N/A"
::= {acAnalogFxsLineTestEntry 11}
acAnalogCommonAction OBJECT IDENTIFIER ::= {acAnalogAction 3}
-- ****************************************
-- acAnalogCommonChannel table declaration
-- ****************************************
acAnalogCommonChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcAnalogCommonChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table for common channels operations."
::= {acAnalogCommonAction 1}
-- ****************************************
-- acAnalogCommonChannel table entry
-- ****************************************
acAnalogCommonChannelEntry OBJECT-TYPE
SYNTAX AcAnalogCommonChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acAnalogCommonChannelIndex}
::= {acAnalogCommonChannelTable 1}
-- ****************************************
-- acAnalogCommonChannel TABLE
-- ****************************************
AcAnalogCommonChannelEntry ::= SEQUENCE {
acAnalogCommonChannelIndex Unsigned32,
acAnalogCommonChannelAction INTEGER
}
acAnalogCommonChannelIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..5000)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index for table use, the current channel.
AC INI-Param: N/A"
::= {acAnalogCommonChannelEntry 1}
acAnalogCommonChannelAction OBJECT-TYPE
SYNTAX INTEGER {
noAction(0)
,
reset(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An action to make on the current channel, The Reset action is
for Analog channels only.
AC INI-Param: N/A"
::= {acAnalogCommonChannelEntry 2}
acAnalogLegs OBJECT IDENTIFIER ::= {acAnalogStatus 21}
-- ****************************************
-- acAnalogLegs table declaration
-- ****************************************
acAnalogLegsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcAnalogLegsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= {acAnalogLegs 1}
-- ****************************************
-- acAnalogLegs table entry
-- ****************************************
acAnalogLegsEntry OBJECT-TYPE
SYNTAX AcAnalogLegsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX {acAnalogLegsLegIndex}
::= {acAnalogLegsTable 1}
-- ****************************************
-- acAnalogLegs TABLE
-- ****************************************
AcAnalogLegsEntry ::= SEQUENCE {
acAnalogLegsLegIndex Unsigned32,
acAnalogLegsCallIndex Unsigned32,
acAnalogLegsAnalogType INTEGER,
acAnalogLegsEchoCanceller INTEGER,
acAnalogLegsHighPassFilter INTEGER,
acAnalogLegsDTMFDetection INTEGER,
acAnalogLegsVoiceVolume Unsigned32,
acAnalogLegsInputGain Unsigned32,
acAnalogLegsLegName SnmpAdminString
}
acAnalogLegsLegIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..5000)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Decribes The Digital EndPoint In A Call.
AC INI-Param: N/A"
::= {acAnalogLegsEntry 1}
acAnalogLegsCallIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..5000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Decribes The Call which The Rtp EndPoint Participant In It.
AC INI-Param: N/A"
::= {acAnalogLegsEntry 2}
acAnalogLegsAnalogType OBJECT-TYPE
SYNTAX INTEGER {
fxs(1)
,
fxo(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describs whether the board is FXS or FXO.
AC INI-Param: N/A"
::= {acAnalogLegsEntry 3}
acAnalogLegsEchoCanceller OBJECT-TYPE
SYNTAX INTEGER {
disable(0)
,
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables or Disables the Echo Canceller.
AC INI-Param: N/A"
::= {acAnalogLegsEntry 4}
acAnalogLegsHighPassFilter OBJECT-TYPE
SYNTAX INTEGER {
disable(0)
,
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables or Disables theHigh Pass Filter.
AC INI-Param: N/A"
::= {acAnalogLegsEntry 5}
acAnalogLegsDTMFDetection OBJECT-TYPE
SYNTAX INTEGER {
disable(0)
,
enable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enables or Disables the DTMF Detection.
AC INI-Param: N/A"
::= {acAnalogLegsEntry 6}
acAnalogLegsVoiceVolume OBJECT-TYPE
SYNTAX Unsigned32 (0..20000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describs the volume of the voice in dB.
AC INI-Param: N/A"
::= {acAnalogLegsEntry 7}
acAnalogLegsInputGain OBJECT-TYPE
SYNTAX Unsigned32 (0..20000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the Input Gain on the leg in dB.
AC INI-Param: N/A"
::= {acAnalogLegsEntry 8}
acAnalogLegsLegName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the Leg Name as in the Control Protocol.
AC INI-Param: N/A"
::= {acAnalogLegsEntry 9}
END