1776 lines
44 KiB
Plaintext
1776 lines
44 KiB
Plaintext
|
||
AC-ANALOG-MIB DEFINITIONS ::= BEGIN
|
||
|
||
|
||
IMPORTS
|
||
|
||
|
||
OBJECT-TYPE,
|
||
MODULE-IDENTITY FROM SNMPv2-SMI
|
||
TAddress,
|
||
DisplayString,
|
||
DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC
|
||
IpAddress FROM RFC1155-SMI
|
||
Unsigned32,
|
||
Integer32,
|
||
enterprises FROM SNMPv2-SMI
|
||
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
|
||
audioCodes,
|
||
acRegistrations,
|
||
acGeneric,
|
||
acProducts,acBoardMibs FROM AUDIOCODES-TYPES-MIB;
|
||
|
||
|
||
acAnalog MODULE-IDENTITY
|
||
LAST-UPDATED "201207260446Z" --Thursday, July 26 2012
|
||
ORGANIZATION "AudioCodes Ltd"
|
||
CONTACT-INFO
|
||
"Postal: Support
|
||
AudioCodes LTD
|
||
1 Hayarden Street
|
||
Airport City
|
||
Lod, ISRAEL 70151
|
||
Tel: 972-3-9764000
|
||
Fax: 972-3-9764040
|
||
Email: support@audiocodes.com
|
||
Web: www.audiocodes.com"
|
||
|
||
|
||
DESCRIPTION
|
||
""
|
||
|
||
|
||
|
||
|
||
::= {acBoardMibs 8}
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
acAnalogConfiguration OBJECT IDENTIFIER ::= {acAnalog 1}
|
||
|
||
|
||
acAnalogConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 1}
|
||
|
||
|
||
acAnalogMisc OBJECT IDENTIFIER ::= {acAnalogConfig 1}
|
||
|
||
|
||
acAnalogMiscCurrentDisconnectDuration OBJECT-TYPE
|
||
SYNTAX Unsigned32 (200..1500)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Defines the current-disconnect duration (in msec). This value
|
||
is used in generation and detection.
|
||
Access: Offline.
|
||
AC INI-Param: CurrentDisconnectDuration"
|
||
::= {acAnalogMisc 1}
|
||
|
||
|
||
|
||
acAnalogMiscFlashHookPeriod OBJECT-TYPE
|
||
SYNTAX Unsigned32 (25..3000)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Defines the flashhook period (in msec) for both analog and IP
|
||
sides.
|
||
|
||
For the analog side it defines:
|
||
|
||
- The maximal hook-flash detection period (for FXS gateways).
|
||
A longer signal is considered offhook / onhook event.
|
||
|
||
- The hook-flash generation period (for FXO gateways).
|
||
|
||
For the IP side it defines the flash-hook period that is reported
|
||
to IP.
|
||
|
||
The valid range is 25 to 1500. The default value is 700 msec.
|
||
Note: For FXO gateways, a constant of 90 msec must be added
|
||
to the required hook-flash period. For example, to generate
|
||
a 450 msec hook-flash, set <20>FlashHookPeriod<6F> to 540.
|
||
.
|
||
Access: Instant.
|
||
AC INI-Param: FLASHHOOKPERIOD"
|
||
::= {acAnalogMisc 2}
|
||
|
||
|
||
|
||
acAnalogMiscGroundKeyDetection OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disable(0)
|
||
,
|
||
enable(1)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables/disables the analog ground key detection.
|
||
0 = Disable
|
||
1= Enable.
|
||
Access: Offline.
|
||
AC INI-Param: GroundKeyDetection"
|
||
::= {acAnalogMisc 3}
|
||
|
||
|
||
|
||
acAuxiliaryFiles OBJECT IDENTIFIER ::= {acAnalogConfig 2}
|
||
|
||
|
||
acAuxiliaryFilesFxsCoefficients OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE (0..47))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Defines the FXS loop coefficient filename.
|
||
|
||
Max. 47 characters.
|
||
AC INI-Param: FXSCOEFFILENAME"
|
||
::= {acAuxiliaryFiles 1}
|
||
|
||
|
||
|
||
acAuxiliaryFilesFxoCoefficients OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE (0..47))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Defines the FXO loop coefficient filename.
|
||
|
||
Max. 47 characters.
|
||
AC INI-Param: FXOCOEFFILENAME"
|
||
::= {acAuxiliaryFiles 2}
|
||
|
||
|
||
|
||
acAnalogFxoConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 2}
|
||
|
||
|
||
acAnalogFxo OBJECT IDENTIFIER ::= {acAnalogFxoConfig 1}
|
||
|
||
|
||
acAnalogFxoFarEndDisconnectType OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..128)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This parameter sets the source for the acEV_FAR_END_DISCONNECTED
|
||
event (or for the relevant control protocol event). It
|
||
is a bit field parameter, hence (for example) if both CPT and
|
||
current disconnect are required, the parameter should be set
|
||
to 5.
|
||
FarDisconnect contributor:
|
||
1 = CPT
|
||
2 = PolarityReversal
|
||
4 = CurrentDisconnect
|
||
8 = Silence.
|
||
Access: Offline.
|
||
AC INI-Param: FARENDDISCONNECTTYPE"
|
||
::= {acAnalogFxo 1}
|
||
|
||
|
||
|
||
acAnalogFxoCountryCoefficients OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
europe(66)
|
||
,
|
||
unitedStates(70)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Allows the user to modify the line characteristic (AC and DC)
|
||
according to country.
|
||
Access: Offline.
|
||
AC INI-Param: CountryCoefficients"
|
||
::= {acAnalogFxo 2}
|
||
|
||
|
||
|
||
acAnalogFxoDCRemover OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disable(0)
|
||
,
|
||
enable(1)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Determines whether to enable the analog DC remover in the DAA.
|
||
|
||
One of the following values:
|
||
|
||
0 = DC remover is disabled
|
||
1 = DC remover is enabled.
|
||
Access: Offline.
|
||
AC INI-Param: EnableAnalogDCRemover"
|
||
::= {acAnalogFxo 3}
|
||
|
||
|
||
|
||
acAnalogFxoDefaultLinePolarityState OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
positive-polarity(0)
|
||
,
|
||
negative-polarity(1)
|
||
,
|
||
polarity-auto-detect(2)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets the TTX pulses voltage level.
|
||
0 = 0Vrms sinusoidal bursts
|
||
1 = 0.5Vrms sinusoidal bursts
|
||
2 = 1Vrms sinusoidal bursts.
|
||
Access: Offline.
|
||
AC INI-Param: SetDefaultLinePolarityState"
|
||
::= {acAnalogFxo 4}
|
||
|
||
|
||
|
||
acAnalogFxoTxGainControl OBJECT-TYPE
|
||
SYNTAX Integer32 (-15..12)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets gain\attenuation of the FXO Tx path between -15db and 12db.
|
||
default no gain.
|
||
Access: Offline.
|
||
AC INI-Param: FXOTxGainControl"
|
||
::= {acAnalogFxo 5}
|
||
|
||
|
||
|
||
acAnalogFxoRxGainControl OBJECT-TYPE
|
||
SYNTAX Integer32 (-15..12)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets gain\attenuation of the FXO Rx path between -15db and 12db.
|
||
default no gain.
|
||
Access: Offline.
|
||
AC INI-Param: FXORxGainControl"
|
||
::= {acAnalogFxo 6}
|
||
|
||
|
||
|
||
-- ****************************************
|
||
-- acAnalogFxoFarEndDisconnectTone table declaration
|
||
-- ****************************************
|
||
acAnalogFxoFarEndDisconnectToneTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF AcAnalogFxoFarEndDisconnectToneEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
""
|
||
::= {acAnalogFxo 21}
|
||
|
||
|
||
|
||
-- ****************************************
|
||
-- acAnalogFxoFarEndDisconnectTone table entry
|
||
-- ****************************************
|
||
acAnalogFxoFarEndDisconnectToneEntry OBJECT-TYPE
|
||
SYNTAX AcAnalogFxoFarEndDisconnectToneEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
""
|
||
INDEX {acAnalogFxoFarEndDisconnectToneIndex}
|
||
::= {acAnalogFxoFarEndDisconnectToneTable 1}
|
||
|
||
|
||
|
||
-- ****************************************
|
||
-- acAnalogFxoFarEndDisconnectTone TABLE
|
||
-- ****************************************
|
||
AcAnalogFxoFarEndDisconnectToneEntry ::= SEQUENCE {
|
||
acAnalogFxoFarEndDisconnectToneRowStatus Unsigned32,
|
||
acAnalogFxoFarEndDisconnectToneAction Unsigned32,
|
||
acAnalogFxoFarEndDisconnectToneActionResult Unsigned32,
|
||
acAnalogFxoFarEndDisconnectToneIndex Unsigned32,
|
||
acAnalogFxoFarEndDisconnectToneType INTEGER
|
||
}
|
||
|
||
|
||
|
||
acAnalogFxoFarEndDisconnectToneRowStatus OBJECT-TYPE
|
||
SYNTAX Unsigned32 (1..1)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Far End Disconnect table row-status.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxoFarEndDisconnectToneEntry 1}
|
||
|
||
|
||
|
||
acAnalogFxoFarEndDisconnectToneAction OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..0)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Far End Disconnect table action.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxoFarEndDisconnectToneEntry 2}
|
||
|
||
|
||
|
||
acAnalogFxoFarEndDisconnectToneActionResult OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..0)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Far End Disconnect table result.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxoFarEndDisconnectToneEntry 3}
|
||
|
||
|
||
|
||
acAnalogFxoFarEndDisconnectToneIndex OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..4)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for table use.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxoFarEndDisconnectToneEntry 4}
|
||
|
||
|
||
|
||
acAnalogFxoFarEndDisconnectToneType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
acNullTone(0)
|
||
,
|
||
acDialTone(1)
|
||
,
|
||
acRingingTone(2)
|
||
,
|
||
acBusyTone(3)
|
||
,
|
||
acCongestionTone(4)
|
||
,
|
||
acSpecialInfoTone(5)
|
||
,
|
||
acWarningTone(6)
|
||
,
|
||
acReorderTone(7)
|
||
,
|
||
acConfirmationTone(8)
|
||
,
|
||
acWaitingTone(9)
|
||
,
|
||
acCallProgressCo1Tone(10)
|
||
,
|
||
acCallProgressCo2Tone(11)
|
||
,
|
||
acOldMilliwattTone(12)
|
||
,
|
||
acNewMilliwattTone(13)
|
||
,
|
||
acMessageWaitingIndicator(14)
|
||
,
|
||
acStutterDialTone(15)
|
||
,
|
||
acStutterOffHookWarningTone(16)
|
||
,
|
||
acWaitingTone1(17)
|
||
,
|
||
acComfortTone(18)
|
||
,
|
||
acNAKTone(19)
|
||
,
|
||
acVacantNumberTone(20)
|
||
,
|
||
acSpecialConditionTone(21)
|
||
,
|
||
acDialTone2(22)
|
||
,
|
||
acOnHoldTone(23)
|
||
,
|
||
acCallTransferDialTone(24)
|
||
,
|
||
acCallForwardTone(25)
|
||
,
|
||
acCreditCardServiceTone(26)
|
||
,
|
||
acSpecialRecallDialTone(27)
|
||
,
|
||
acAlertingTone(28)
|
||
,
|
||
acNetworkCongestionTone(29)
|
||
,
|
||
acWaitingTone2(30)
|
||
,
|
||
acWaitingTone3(31)
|
||
,
|
||
acWaitingTone4(32)
|
||
,
|
||
acConfEnterTone(33)
|
||
,
|
||
acConfExitTone(34)
|
||
,
|
||
acConfLockTone(35)
|
||
,
|
||
acConfUnlockTone(36)
|
||
,
|
||
acConfTimeLimitTone(37)
|
||
,
|
||
acPayphoneRecognitionTone(38)
|
||
,
|
||
acCallerWaitingTone(39)
|
||
,
|
||
acCNGFaxTone(40)
|
||
,
|
||
acPrecConfNotifyType(41)
|
||
,
|
||
acPresConfNotifyType(42)
|
||
,
|
||
acPrecPreemptType(43)
|
||
,
|
||
acPrecRTType(44)
|
||
,
|
||
acR15reqOfANItone(45)
|
||
,
|
||
acCo1Tone(200)
|
||
,
|
||
acCo2Tone(201)
|
||
,
|
||
acPlayRecordBeepTone(202)
|
||
,
|
||
acTrunkTestingTestProgressTone(203)
|
||
,
|
||
acTrunkTestingTestTone(204)
|
||
,
|
||
acTrunkTestingGuardTone(205)
|
||
,
|
||
acFSKTrunkTestingTone(206)
|
||
,
|
||
acGeneralTrunkTestingTone1(207)
|
||
,
|
||
acGeneralTrunkTestingTone2(208)
|
||
,
|
||
acGeneralTrunkTestingTone3(209)
|
||
,
|
||
acSpecialInfoToneFirst(210)
|
||
,
|
||
acSpecialInfoToneSecond(211)
|
||
,
|
||
acSpecialInfoToneThird(212)
|
||
,
|
||
acTTYTone(213)
|
||
,
|
||
acTT904ContinuityTone(214)
|
||
,
|
||
acTTMilliwattLossMeasureTone(215)
|
||
,
|
||
acCarrierDialTone(216)
|
||
,
|
||
acCarrierAnswerTone(217)
|
||
,
|
||
acCarrierChargingTone(218)
|
||
,
|
||
acLongDistanceIndicatorTone(219)
|
||
,
|
||
acSTUModemFirstTone(298)
|
||
,
|
||
acSTUModemSecondTone(299)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Defines which CPT types are detected as far-end disconnect.
|
||
The CPT type is based on the acTCallProgressToneType enum.
|
||
This is valid when FarEndDisconnectType allows CPT detection.
|
||
|
||
Range = An array of up to 4 tone types.
|
||
Access: Offline.
|
||
AC INI-Param: DISCONNECTTONETYPE"
|
||
::= {acAnalogFxoFarEndDisconnectToneEntry 5}
|
||
|
||
|
||
|
||
acAnalogFxsConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 3}
|
||
|
||
|
||
acAnalogFxs OBJECT IDENTIFIER ::= {acAnalogFxsConfig 1}
|
||
|
||
|
||
acAnalogFxsPolarityReversalType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
soft(0)
|
||
,
|
||
hard(1)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets the type of the polarity reversal signal used for the network
|
||
far-end answer and disconnect indications. Smooth reversal
|
||
prevents negative effects as non-required ringing.
|
||
0 = Soft reverse polarity
|
||
1 = Hard reverse polarity.
|
||
Access: Offline.
|
||
AC INI-Param: POLARITYREVERSALTYPE"
|
||
::= {acAnalogFxs 1}
|
||
|
||
|
||
|
||
acAnalogFxsMeteringType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
mt12kHz(0)
|
||
,
|
||
mt16kHz(1)
|
||
,
|
||
mtPolarityReversal(2)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets the metering method for charging pulses.
|
||
0 = 12 kHz sinusoidal bursts
|
||
1 = 16 kHz sinusoidal bursts
|
||
2 = Polarity Reversal pulses.
|
||
Access: Offline.
|
||
AC INI-Param: METERINGTYPE"
|
||
::= {acAnalogFxs 2}
|
||
|
||
|
||
|
||
acAnalogFxsLifeLineType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
acLifeLineType-Hardware-Only(0)
|
||
,
|
||
acLifeLineTypeHardware-And-Link-Detection(1)
|
||
,
|
||
acLifeLineType-Hardware-And-Link-And-Network-Detection(2)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Defines the Lifeline phone type. The Lifeline phone is available
|
||
(for FXS only) on port 4 in MP-104 and MP-108, on port
|
||
2 in MP-102, on ports 1-4 in the MP-118, and on port 2 of each
|
||
analog module in the Mediant 1000.
|
||
0 = activate Lifeline phone on power down
|
||
1 = activate Lifeline phone on power down or on detection of
|
||
LAN disconnect
|
||
2 = activate Lifeline phone on power down, or on detection
|
||
of LAN disconnect, or on loss of ping.
|
||
Access: Offline.
|
||
AC INI-Param: LIFELINETYPE"
|
||
::= {acAnalogFxs 3}
|
||
|
||
|
||
|
||
acAnalogFxsMinFlashHookTime OBJECT-TYPE
|
||
SYNTAX Unsigned32 (25..300)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets the minimal time (in msec) for detection of a flash-hook
|
||
event (for FXS only). The valid range is 25 to 300. The default
|
||
value is 300 msec.
|
||
|
||
Detection is guaranteed for flash hook periods of at least
|
||
60 msec (when setting the minimal time to 25). Flash-hook signals
|
||
that last a shorter period of time are ignored.
|
||
|
||
Note: It is recommended to reduce the detection time by 50
|
||
msec from the desired value (e.g. if you set the value as 200
|
||
msec, then enter 150 msec, i.e. 200 minus 50).
|
||
.
|
||
Access: Offline.
|
||
AC INI-Param: MINFLASHHOOKTIME"
|
||
::= {acAnalogFxs 4}
|
||
|
||
|
||
|
||
acAnalogFxsCallerIDTimingMode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disable(0)
|
||
,
|
||
enable(1)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Defines the Analog CallerID Timing Mode.
|
||
|
||
0 = CallerID transferred between first and second rings
|
||
1 = CallerID transferred on valid Off ring.
|
||
Access: Offline.
|
||
AC INI-Param: ANALOGCALLERIDTIMINGMODE"
|
||
::= {acAnalogFxs 5}
|
||
|
||
|
||
|
||
acAnalogFxsBellcoreCallerIDTypeOneSubStandard OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
bellcore-Between-Rings(0)
|
||
,
|
||
bellcore-Not-Ring-Related(1)
|
||
,
|
||
bellcore-Before-Ring-RP-AS(2)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Selects the sub-standard of the Bellcore Caller ID type.
|
||
|
||
0 = Between_Rings
|
||
1 = Not_Ring_Related
|
||
2 = Before_Ring_RP_AS.
|
||
Access: Offline.
|
||
AC INI-Param: BellcoreCallerIDTypeOneSubStandard"
|
||
::= {acAnalogFxs 6}
|
||
|
||
|
||
|
||
acAnalogFxsETSICallerIDTypeOneSubStandard OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eTSI-Between-Rings(0)
|
||
,
|
||
eTSI-Before-Ring-DT-AS(1)
|
||
,
|
||
eTSI-Before-Ring-RP-AS(2)
|
||
,
|
||
eTSI-Before-Ring-LR-DT-AS(3)
|
||
,
|
||
eTSI-Not-Ring-Related-DT-AS(4)
|
||
,
|
||
eTSI-Not-Ring-Related-RP-AS(5)
|
||
,
|
||
eTSI-Not-Ring-Related-LR-DT-AS(6)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Selects the number denoting the ETSI CallerID Type 1 sub-standard.
|
||
Either:
|
||
0 = ETSI_Between_Rings
|
||
1 = ETSI_Before_Ring_DT_AS
|
||
2 = ETSI_Before_Ring_RP_AS
|
||
3 = ETSI_Before_Ring_LR_DT_AS
|
||
4 = ETSI_Not_Ring_Related_DT_AS
|
||
5 = ETSI_Not_Ring_Related_RP_AS
|
||
6 = ETSI_Not_Ring_Related_LR_DT_AS.
|
||
Access: Offline.
|
||
AC INI-Param: ETSICallerIDTypeOneSubStandard"
|
||
::= {acAnalogFxs 7}
|
||
|
||
|
||
|
||
acAnalogFxsETSIVMWITypeOneStandard OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
eTSI-VMWI-Between-Rings(0)
|
||
,
|
||
eTSI-VMWI-Before-Ring-DT-AS(1)
|
||
,
|
||
eTSI-VMWI-Before-Ring-RP-AS(2)
|
||
,
|
||
eTSI-VMWI-Before-Ring-LR-DT-AS(3)
|
||
,
|
||
eTSI-VMWI-Not-Ring-Related-DT-AS(4)
|
||
,
|
||
eTSI-VMWI-Not-Ring-Related-RP-AS(5)
|
||
,
|
||
eTSI-VMWI-Not-Ring-Related-LR-DT-AS(6)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Selects the number denoting the ETSI VMWI Type 1 Standard.
|
||
Choose:
|
||
0 = ETSI_VMWI_Between_Rings
|
||
1 = ETSI_VMWI_Before_Ring_DT_AS
|
||
2 = ETSI_VMWI_Before_Ring_RP_AS
|
||
3 = ETSI_VMWI_Before_Ring_LR_DT_AS
|
||
4 = ETSI_VMWI_Not_Ring_Related_DT_AS
|
||
5 = ETSI_VMWI_Not_Ring_Related_RP_AS
|
||
6 = ETSI_VMWI_Not_Ring_Related_LR_DT_AS.
|
||
Access: Offline.
|
||
AC INI-Param: ETSIVMWITypeOneStandard"
|
||
::= {acAnalogFxs 8}
|
||
|
||
|
||
|
||
acAnalogFxsBellcoreVMWITypeOneStandard OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
bellcore-VMWI-Between-Rings(0)
|
||
,
|
||
bellcore-VMWI-Not-Ring-Related(1)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Use this parameter to select the Bellcore VMWI standard.
|
||
|
||
0 - Between_Rings
|
||
1 - Not_Ring_Related.
|
||
Access: Offline.
|
||
AC INI-Param: BellcoreVMWITypeOneStandard"
|
||
::= {acAnalogFxs 9}
|
||
|
||
|
||
|
||
acAnalogFxsDisableAutoCalibration OBJECT-TYPE
|
||
SYNTAX Unsigned32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Determines whether to enable the analog Autocalibration in the
|
||
DAA.
|
||
|
||
One of the following values:
|
||
|
||
0 = Auto calibration is enabled
|
||
1 = Auto calibration is disabled.
|
||
Access: Offline.
|
||
AC INI-Param: DisableAnalogAutoCalibration"
|
||
::= {acAnalogFxs 10}
|
||
|
||
|
||
|
||
acAnalogFxsExternalLifeLinePorts OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..24)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set the amount of FXS ports which will be connected to an external
|
||
life line and will be disabled (max value is half of
|
||
the FXS ports).
|
||
Access: Offline.
|
||
AC INI-Param: ExternalLifeLinePorts"
|
||
::= {acAnalogFxs 11}
|
||
|
||
|
||
|
||
acAnalogFxsCountryCoefficients OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
europe(66)
|
||
,
|
||
unitedStates(70)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Allows the user to modify the line characteristic (AC and DC)
|
||
according to country.
|
||
Access: Offline.
|
||
AC INI-Param: FXSCountryCoefficients"
|
||
::= {acAnalogFxs 12}
|
||
|
||
|
||
|
||
acAnalogFxsTTXVoltageLevel OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
notAvailable(-1)
|
||
,
|
||
ttxVoltageLevel0V(0)
|
||
,
|
||
ttxVoltageLevel05(1)
|
||
,
|
||
ttxVoltageLevel1V(2)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets the TTX pulses voltage level.
|
||
0 = 0Vrms sinusoidal bursts
|
||
1 = 0.5Vrms sinusoidal bursts
|
||
2 = 1Vrms sinusoidal bursts
|
||
-1 = notAvailable.
|
||
Access: Offline.
|
||
AC INI-Param: AnalogTTXVoltageLevel"
|
||
::= {acAnalogFxs 13}
|
||
|
||
|
||
|
||
acAnalogEMConfig OBJECT IDENTIFIER ::= {acAnalogConfiguration 4}
|
||
|
||
|
||
acAnalogEM OBJECT IDENTIFIER ::= {acAnalogEMConfig 1}
|
||
|
||
|
||
acAnalogEMVoiceType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
twoWire(0)
|
||
,
|
||
fourWire(1)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"E&M Voice Configuration Type 2 or 4 wire.
|
||
Access: Offline.
|
||
AC INI-Param: EnMVoiceType"
|
||
::= {acAnalogEM 1}
|
||
|
||
|
||
|
||
acAnalogEMInterfaceType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
signaling(0)
|
||
,
|
||
trunking(1)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"E&M Signaling Type - Trunking or Signaling.
|
||
Access: Offline.
|
||
AC INI-Param: EnMSystemType"
|
||
::= {acAnalogEM 2}
|
||
|
||
|
||
|
||
acAnalogEMSignalingType OBJECT-TYPE
|
||
SYNTAX Unsigned32 (1..5)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Set E&M standatd signaling types are described in TIA/EIA-464C.
|
||
Access: Offline.
|
||
AC INI-Param: EnMSignalingType"
|
||
::= {acAnalogEM 3}
|
||
|
||
|
||
|
||
acAnalogEMPortRXGain OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disable(0)
|
||
,
|
||
enable(1)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Rx Gain.
|
||
Access: Offline.
|
||
AC INI-Param: EnMPortRXGain"
|
||
::= {acAnalogEM 4}
|
||
|
||
|
||
|
||
acAnalogEMPortTXGain OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disable(0)
|
||
,
|
||
enable(1)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Tx Gain.
|
||
Access: Offline.
|
||
AC INI-Param: EnMPortTXGain"
|
||
::= {acAnalogEM 5}
|
||
|
||
|
||
|
||
acAnalogEMCountryCoefficients OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unitedStates(0)
|
||
,
|
||
europe(1)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"E&M Country Coefficients.
|
||
Access: Offline.
|
||
AC INI-Param: EnMCountryCoefficients"
|
||
::= {acAnalogEM 6}
|
||
|
||
|
||
|
||
acAnalogEMHookDebounceTiming OBJECT-TYPE
|
||
SYNTAX Unsigned32 (30..150)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Sets the on E&M hook detection debounce timing.
|
||
Access: Offline.
|
||
AC INI-Param: EnMhookDebounceTiming"
|
||
::= {acAnalogEM 7}
|
||
|
||
|
||
|
||
acAnalogEMOffHookGlareEnable OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disable(0)
|
||
,
|
||
enable(1)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Protect the EnM port from Rx and Tx hook collision.
|
||
Access: Offline.
|
||
AC INI-Param: EnMOffHookGlareEnable"
|
||
::= {acAnalogEM 8}
|
||
|
||
|
||
|
||
acAnalogStatus OBJECT IDENTIFIER ::= {acAnalog 2}
|
||
|
||
|
||
acAnalogStatusMisc OBJECT IDENTIFIER ::= {acAnalogStatus 1}
|
||
|
||
|
||
acAnalogStatusMiscFxsOrFxo OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
fXO(0)
|
||
,
|
||
fXS(1)
|
||
,
|
||
eANDm(2)
|
||
,
|
||
fXOandFXS(3)
|
||
,
|
||
fXOandFXSandEM(5)
|
||
,
|
||
fXOandEM(6)
|
||
,
|
||
fXSandEM(7)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Board is Fxs,Fxo, FXS_FXO or E&M.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogStatusMisc 1}
|
||
|
||
|
||
|
||
acAnalogStatusMiscBoardTemperature OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..100)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Temperature of the board in degrees Celsius, should not go higher
|
||
then 60!.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogStatusMisc 2}
|
||
|
||
|
||
|
||
acAnalogStatusMiscAnalogChannelsCount OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..5000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Number of the Analog channels in the board.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogStatusMisc 3}
|
||
|
||
|
||
|
||
acAnalogFxsFxo OBJECT IDENTIFIER ::= {acAnalogStatus 20}
|
||
|
||
|
||
-- ****************************************
|
||
-- acAnalogFxsFxo table declaration
|
||
-- ****************************************
|
||
acAnalogFxsFxoTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF AcAnalogFxsFxoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
""
|
||
::= {acAnalogFxsFxo 1}
|
||
|
||
|
||
|
||
-- ****************************************
|
||
-- acAnalogFxsFxo table entry
|
||
-- ****************************************
|
||
acAnalogFxsFxoEntry OBJECT-TYPE
|
||
SYNTAX AcAnalogFxsFxoEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
""
|
||
INDEX {acAnalogFxsFxoIndex}
|
||
::= {acAnalogFxsFxoTable 1}
|
||
|
||
|
||
|
||
-- ****************************************
|
||
-- acAnalogFxsFxo TABLE
|
||
-- ****************************************
|
||
AcAnalogFxsFxoEntry ::= SEQUENCE {
|
||
acAnalogFxsFxoIndex Unsigned32,
|
||
acAnalogFxsFxoType INTEGER,
|
||
acAnalogFxsFxoChipRevNum Unsigned32,
|
||
acAnalogFxsFxoHookState INTEGER
|
||
}
|
||
|
||
|
||
|
||
acAnalogFxsFxoIndex OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..24)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for table use.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxsFxoEntry 1}
|
||
|
||
|
||
|
||
acAnalogFxsFxoType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
fXO(0)
|
||
,
|
||
fXS(1)
|
||
,
|
||
eM(2)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Line is Fxs, Fxo or E&M.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxsFxoEntry 2}
|
||
|
||
|
||
|
||
acAnalogFxsFxoChipRevNum OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Fxs/Fxo's Chip revision number.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxsFxoEntry 3}
|
||
|
||
|
||
|
||
acAnalogFxsFxoHookState OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
onHookState(1)
|
||
,
|
||
offHookState(2)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The hook state of the analog line.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxsFxoEntry 4}
|
||
|
||
|
||
|
||
acAnalogAction OBJECT IDENTIFIER ::= {acAnalog 3}
|
||
|
||
|
||
acAnalogFxoAction OBJECT IDENTIFIER ::= {acAnalogAction 1}
|
||
|
||
|
||
-- ****************************************
|
||
-- acAnalogFxoLineTest table declaration
|
||
-- ****************************************
|
||
acAnalogFxoLineTestTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF AcAnalogFxoLineTestEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
""
|
||
::= {acAnalogFxoAction 1}
|
||
|
||
|
||
|
||
-- ****************************************
|
||
-- acAnalogFxoLineTest table entry
|
||
-- ****************************************
|
||
acAnalogFxoLineTestEntry OBJECT-TYPE
|
||
SYNTAX AcAnalogFxoLineTestEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
""
|
||
INDEX {acAnalogFxoLineTestIndex}
|
||
::= {acAnalogFxoLineTestTable 1}
|
||
|
||
|
||
|
||
-- ****************************************
|
||
-- acAnalogFxoLineTest TABLE
|
||
-- ****************************************
|
||
AcAnalogFxoLineTestEntry ::= SEQUENCE {
|
||
acAnalogFxoLineTestIndex Unsigned32,
|
||
acAnalogFxoLineTestActivate INTEGER,
|
||
acAnalogFxoLineTestHookState INTEGER,
|
||
acAnalogFxoLineTestPolarityStatus INTEGER,
|
||
acAnalogFxoLineTestLineConnectionStatus INTEGER,
|
||
acAnalogFxoLineTestLineCurrent Integer32,
|
||
acAnalogFxoLineTestLineVoltage Integer32,
|
||
acAnalogFxoLineTestRingState INTEGER,
|
||
acAnalogFxoLineTestLinePolarity INTEGER,
|
||
acAnalogFxoLineTestMwiState INTEGER,
|
||
acAnalogFxoLineTestLastCurrentDisconnectDuration
|
||
Unsigned32
|
||
}
|
||
|
||
|
||
|
||
acAnalogFxoLineTestIndex OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..24)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for table use.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxoLineTestEntry 1}
|
||
|
||
|
||
|
||
acAnalogFxoLineTestActivate OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
noTestActivated(0)
|
||
,
|
||
runLineTest(1)
|
||
,
|
||
lineTestDone(2)
|
||
,
|
||
testFailed(3)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Activate line testing in an FXO analog line according to a given
|
||
line-index.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxoLineTestEntry 2}
|
||
|
||
|
||
|
||
acAnalogFxoLineTestHookState OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
onHookState(1)
|
||
,
|
||
offHookState(2)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The hook state of the analog line.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxoLineTestEntry 3}
|
||
|
||
|
||
|
||
acAnalogFxoLineTestPolarityStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
normalPolarity(1)
|
||
,
|
||
reversePolarity(2)
|
||
,
|
||
notAvailable(3)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The line's polarity state.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxoLineTestEntry 4}
|
||
|
||
|
||
|
||
acAnalogFxoLineTestLineConnectionStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
lineDisconnected(1)
|
||
,
|
||
lineConnected(2)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The connection's status of the line.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxoLineTestEntry 5}
|
||
|
||
|
||
|
||
acAnalogFxoLineTestLineCurrent OBJECT-TYPE
|
||
SYNTAX Integer32 (-1..24)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The line's current [ma].
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxoLineTestEntry 6}
|
||
|
||
|
||
|
||
acAnalogFxoLineTestLineVoltage OBJECT-TYPE
|
||
SYNTAX Integer32 (-128..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The line's voltage [V].
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxoLineTestEntry 7}
|
||
|
||
|
||
|
||
acAnalogFxoLineTestRingState OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
off(1)
|
||
,
|
||
on(2)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Ring's State.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxoLineTestEntry 8}
|
||
|
||
|
||
|
||
acAnalogFxoLineTestLinePolarity OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
positive(1)
|
||
,
|
||
negative(2)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The line's polarity state.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxoLineTestEntry 9}
|
||
|
||
|
||
|
||
acAnalogFxoLineTestMwiState OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
off(1)
|
||
,
|
||
on(2)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Mwi's state.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxoLineTestEntry 10}
|
||
|
||
|
||
|
||
acAnalogFxoLineTestLastCurrentDisconnectDuration OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..2147483647)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Last current disconnect duration in msec.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxoLineTestEntry 11}
|
||
|
||
|
||
|
||
acAnalogFxsAction OBJECT IDENTIFIER ::= {acAnalogAction 2}
|
||
|
||
|
||
-- ****************************************
|
||
-- acAnalogFxsLineTest table declaration
|
||
-- ****************************************
|
||
acAnalogFxsLineTestTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF AcAnalogFxsLineTestEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
""
|
||
::= {acAnalogFxsAction 1}
|
||
|
||
|
||
|
||
-- ****************************************
|
||
-- acAnalogFxsLineTest table entry
|
||
-- ****************************************
|
||
acAnalogFxsLineTestEntry OBJECT-TYPE
|
||
SYNTAX AcAnalogFxsLineTestEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
""
|
||
INDEX {acAnalogFxsLineTestIndex}
|
||
::= {acAnalogFxsLineTestTable 1}
|
||
|
||
|
||
|
||
-- ****************************************
|
||
-- acAnalogFxsLineTest TABLE
|
||
-- ****************************************
|
||
AcAnalogFxsLineTestEntry ::= SEQUENCE {
|
||
acAnalogFxsLineTestIndex Unsigned32,
|
||
acAnalogFxsLineTestActivate INTEGER,
|
||
acAnalogFxsLineTestHookState INTEGER,
|
||
acAnalogFxsLineTestRingState INTEGER,
|
||
acAnalogFxsLineTestPolarityStatus INTEGER,
|
||
acAnalogFxsLineTestMessageWaitingIndication INTEGER,
|
||
acAnalogFxsLineTestLineCurrentReading Unsigned32,
|
||
acAnalogFxsLineTestLineVoltageReading Integer32,
|
||
acAnalogFxsLineTestAnalogVoltageReading Unsigned32,
|
||
acAnalogFxsLineTestRingVoltageReading Integer32,
|
||
acAnalogFxsLineTestLongLineCurrentReading Unsigned32
|
||
}
|
||
|
||
|
||
|
||
acAnalogFxsLineTestIndex OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..24)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for table use.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxsLineTestEntry 1}
|
||
|
||
|
||
|
||
acAnalogFxsLineTestActivate OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
noTestActivated(0)
|
||
,
|
||
runLineTest(1)
|
||
,
|
||
lineTestDone(2)
|
||
,
|
||
testFailed(3)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Activate line testing in a FXS analog line according to a given
|
||
line-index.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxsLineTestEntry 2}
|
||
|
||
|
||
|
||
acAnalogFxsLineTestHookState OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
onHookState(1)
|
||
,
|
||
offHookState(2)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The hook state of the analog line.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxsLineTestEntry 3}
|
||
|
||
|
||
|
||
acAnalogFxsLineTestRingState OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
offRingState(1)
|
||
,
|
||
onRingState(2)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Line's ring state.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxsLineTestEntry 4}
|
||
|
||
|
||
|
||
acAnalogFxsLineTestPolarityStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
normalPolarity(1)
|
||
,
|
||
reversePolarity(2)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Line's reversal-polarity.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxsLineTestEntry 5}
|
||
|
||
|
||
|
||
acAnalogFxsLineTestMessageWaitingIndication OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
noWaitingMessage(1)
|
||
,
|
||
waitingMessage(2)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Line's messgae waiting indication state.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxsLineTestEntry 6}
|
||
|
||
|
||
|
||
acAnalogFxsLineTestLineCurrentReading OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..3000)
|
||
MAX-ACCESS read-only
|
||
STATUS obsolete
|
||
DESCRIPTION
|
||
"The Line current reading in 10ua units.
|
||
This test is supported only in line no. 0.
|
||
Not supported on MP500.
|
||
In case of MP124 this test is supported in all ports except
|
||
ports 2 and 3.
|
||
As of version 6.6 this is an obsolete parameter.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxsLineTestEntry 7}
|
||
|
||
|
||
|
||
acAnalogFxsLineTestLineVoltageReading OBJECT-TYPE
|
||
SYNTAX Integer32 (-6000..6000)
|
||
MAX-ACCESS read-only
|
||
STATUS obsolete
|
||
DESCRIPTION
|
||
"The Line voltage reading in 10mV units.
|
||
In case of MP124 the Line voltage reading in 1V units.
|
||
This test is supported only in line no. 0.
|
||
Not supported on MP500.
|
||
In case of MP124 this test is supported in all ports except
|
||
ports 2 and 3.
|
||
As of version 6.6 this is an obsolete parameter.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxsLineTestEntry 8}
|
||
|
||
|
||
|
||
acAnalogFxsLineTestAnalogVoltageReading OBJECT-TYPE
|
||
SYNTAX Unsigned32 (300..340)
|
||
MAX-ACCESS read-only
|
||
STATUS obsolete
|
||
DESCRIPTION
|
||
"The current analog voltage reading in 10mV units.
|
||
his test is supported only in line no. 0.
|
||
Not supported on MP500.
|
||
In case of MP124 this test is supported in all ports except
|
||
ports 2 and 3.
|
||
As of version 6.6 this is an obsolete parameter.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxsLineTestEntry 9}
|
||
|
||
|
||
|
||
acAnalogFxsLineTestRingVoltageReading OBJECT-TYPE
|
||
SYNTAX Integer32 (-13000..13000)
|
||
MAX-ACCESS read-only
|
||
STATUS obsolete
|
||
DESCRIPTION
|
||
"The current ring voltage reading in 10mV units.
|
||
This test is supported only in line no. 0.
|
||
Not supported on MP500.
|
||
In case of MP124 this test is supported in all ports except
|
||
ports 2 and 3.
|
||
As of version 6.6 this is an obsolete parameter.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxsLineTestEntry 10}
|
||
|
||
|
||
|
||
acAnalogFxsLineTestLongLineCurrentReading OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..4000)
|
||
MAX-ACCESS read-only
|
||
STATUS obsolete
|
||
DESCRIPTION
|
||
"The current long line reading in 10ua units.
|
||
This test is supported only in line no. 0.
|
||
Not supported on MP500.
|
||
In case of MP124 this test is supported in all ports except
|
||
ports 2 and 3.
|
||
As of version 6.6 this is an obsolete parameter.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogFxsLineTestEntry 11}
|
||
|
||
|
||
|
||
acAnalogCommonAction OBJECT IDENTIFIER ::= {acAnalogAction 3}
|
||
|
||
|
||
-- ****************************************
|
||
-- acAnalogCommonChannel table declaration
|
||
-- ****************************************
|
||
acAnalogCommonChannelTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF AcAnalogCommonChannelEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table for common channels operations."
|
||
::= {acAnalogCommonAction 1}
|
||
|
||
|
||
|
||
-- ****************************************
|
||
-- acAnalogCommonChannel table entry
|
||
-- ****************************************
|
||
acAnalogCommonChannelEntry OBJECT-TYPE
|
||
SYNTAX AcAnalogCommonChannelEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
""
|
||
INDEX {acAnalogCommonChannelIndex}
|
||
::= {acAnalogCommonChannelTable 1}
|
||
|
||
|
||
|
||
-- ****************************************
|
||
-- acAnalogCommonChannel TABLE
|
||
-- ****************************************
|
||
AcAnalogCommonChannelEntry ::= SEQUENCE {
|
||
acAnalogCommonChannelIndex Unsigned32,
|
||
acAnalogCommonChannelAction INTEGER
|
||
}
|
||
|
||
|
||
|
||
acAnalogCommonChannelIndex OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..5000)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for table use, the current channel.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogCommonChannelEntry 1}
|
||
|
||
|
||
|
||
acAnalogCommonChannelAction OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
noAction(0)
|
||
,
|
||
reset(1)
|
||
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An action to make on the current channel, The Reset action is
|
||
for Analog channels only.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogCommonChannelEntry 2}
|
||
|
||
|
||
|
||
acAnalogLegs OBJECT IDENTIFIER ::= {acAnalogStatus 21}
|
||
|
||
|
||
-- ****************************************
|
||
-- acAnalogLegs table declaration
|
||
-- ****************************************
|
||
acAnalogLegsTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF AcAnalogLegsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
""
|
||
::= {acAnalogLegs 1}
|
||
|
||
|
||
|
||
-- ****************************************
|
||
-- acAnalogLegs table entry
|
||
-- ****************************************
|
||
acAnalogLegsEntry OBJECT-TYPE
|
||
SYNTAX AcAnalogLegsEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
""
|
||
INDEX {acAnalogLegsLegIndex}
|
||
::= {acAnalogLegsTable 1}
|
||
|
||
|
||
|
||
-- ****************************************
|
||
-- acAnalogLegs TABLE
|
||
-- ****************************************
|
||
AcAnalogLegsEntry ::= SEQUENCE {
|
||
acAnalogLegsLegIndex Unsigned32,
|
||
acAnalogLegsCallIndex Unsigned32,
|
||
acAnalogLegsAnalogType INTEGER,
|
||
acAnalogLegsEchoCanceller INTEGER,
|
||
acAnalogLegsHighPassFilter INTEGER,
|
||
acAnalogLegsDTMFDetection INTEGER,
|
||
acAnalogLegsVoiceVolume Unsigned32,
|
||
acAnalogLegsInputGain Unsigned32,
|
||
acAnalogLegsLegName SnmpAdminString
|
||
}
|
||
|
||
|
||
|
||
acAnalogLegsLegIndex OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..5000)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Decribes The Digital EndPoint In A Call.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogLegsEntry 1}
|
||
|
||
|
||
|
||
acAnalogLegsCallIndex OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..5000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Decribes The Call which The Rtp EndPoint Participant In It.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogLegsEntry 2}
|
||
|
||
|
||
|
||
acAnalogLegsAnalogType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
fxs(1)
|
||
,
|
||
fxo(2)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Describs whether the board is FXS or FXO.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogLegsEntry 3}
|
||
|
||
|
||
|
||
acAnalogLegsEchoCanceller OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disable(0)
|
||
,
|
||
enable(1)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables or Disables the Echo Canceller.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogLegsEntry 4}
|
||
|
||
|
||
|
||
acAnalogLegsHighPassFilter OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disable(0)
|
||
,
|
||
enable(1)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables or Disables theHigh Pass Filter.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogLegsEntry 5}
|
||
|
||
|
||
|
||
acAnalogLegsDTMFDetection OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disable(0)
|
||
,
|
||
enable(1)
|
||
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enables or Disables the DTMF Detection.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogLegsEntry 6}
|
||
|
||
|
||
|
||
acAnalogLegsVoiceVolume OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..20000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Describs the volume of the voice in dB.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogLegsEntry 7}
|
||
|
||
|
||
|
||
acAnalogLegsInputGain OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..20000)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Describes the Input Gain on the leg in dB.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogLegsEntry 8}
|
||
|
||
|
||
|
||
acAnalogLegsLegName OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE (0..64))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Describes the Leg Name as in the Control Protocol.
|
||
AC INI-Param: N/A"
|
||
::= {acAnalogLegsEntry 9}
|
||
|
||
|
||
|
||
|
||
|
||
END
|