mibs/MIBS/awplus/AT-ENVMONv2-MIB
2023-12-05 12:25:34 +01:00

1394 lines
52 KiB
Plaintext

-- ============================================================================
-- AT-ENVMONv2-MIB, Allied Telesis enterprise MIB:
-- Environment Monitoring MIB objects.
--
-- Copyright (c) 2008 by Allied Telesis, Inc.
-- All rights reserved.
--
-- ============================================================================
AT-ENVMONv2-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayStringUnsized
FROM AT-SMI-MIB
sysinfo
FROM AT-SYSINFO-MIB
Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
TEXTUAL-CONVENTION
FROM SNMPv2-TC;
atEnvMonv2 MODULE-IDENTITY
LAST-UPDATED "201610300000Z"
ORGANIZATION
"Allied Telesis, Inc"
CONTACT-INFO
"http://www.alliedtelesis.com"
DESCRIPTION
"The AT Environment Monitoring v2 MIB for managing and
reporting data relating to voltage rails, fan speeds,
temperature sensors and power supply units."
REVISION "201610300000Z"
DESCRIPTION
"Swapped external PSU status failed/good states"
REVISION "201606280000Z"
DESCRIPTION
"Added support for level 1 and level 2 critical temperature events."
REVISION "201406070000Z"
DESCRIPTION
"Additions for Industrial Ethernet support (i.e. contact input, contact output, external PSU status)."
REVISION "201406060000Z"
DESCRIPTION
"Added more descriptions to FanStackMemberId, VoltageStackMemberId,
TemperatureStackMemberId, PsbHostStackMemberId, PsbSensorStackMemberId,
and FaultLedStackMemberId."
REVISION "201403310000Z"
DESCRIPTION
"Added support for critical temperature events"
REVISION "201209210000Z"
DESCRIPTION
"Added chassis switch (e.g. SBx8100) descriptions to stack-related MIB objects"
REVISION "201009150000Z"
DESCRIPTION
"Add atEnvMonv2PsbSensorReading field to atEnvMonv2PsbSensorEntry"
REVISION "201009070000Z"
DESCRIPTION
"Generic syntax tidy up"
REVISION "201006140450Z"
DESCRIPTION
"MIB revision history dates in descriptions updated."
REVISION "201005240119Z"
DESCRIPTION
"OID of atEnvMonv2Traps reverted to 5 but deprecated. Added atEnvMonv2Notifications"
REVISION "201001150039Z"
DESCRIPTION
"Changed the OID value of atEnvMonv2Traps from 5 to 0 to meet RFC 3584 3.1"
REVISION "200811260000Z"
DESCRIPTION
"Removed recently added MIB objects that went against the
original intent of the environment monitoring MIB."
REVISION "200809240000Z"
DESCRIPTION
"Appended v2 to all object names to clarify
version number of this mib."
REVISION "200802070000Z"
DESCRIPTION
"Initial Revision"
::= { sysinfo 12 }
--
-- Textual conventions
--
AtEnvMonv2PsbSensorType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates the type of a Power Supply Bay Device sensor."
SYNTAX INTEGER
{
psbSensorTypeInvalid(0),
fanSpeedDiscrete(1),
temperatureDiscrete(2),
voltageDiscrete(3)
}
--
-- Node definitions
--
-- ---------------------------------------------------------- --
-- The Environment Monitoring Notifications Objects
-- ---------------------------------------------------------- --
atEnvMonv2Notifications OBJECT IDENTIFIER ::= { atEnvMonv2 0 }
atEnvMonv2FanAlarmSetNotify NOTIFICATION-TYPE
OBJECTS { atEnvMonv2FanStackMemberId, atEnvMonv2FanBoardIndex, atEnvMonv2FanIndex, atEnvMonv2FanDescription, atEnvMonv2FanLowerThreshold,
atEnvMonv2FanCurrentSpeed }
STATUS current
DESCRIPTION
"A notification generated when the monitored speed of a fan
drops below its lower threshold."
::= { atEnvMonv2Notifications 1 }
atEnvMonv2FanAlarmClearedNotify NOTIFICATION-TYPE
OBJECTS { atEnvMonv2FanStackMemberId, atEnvMonv2FanBoardIndex, atEnvMonv2FanIndex, atEnvMonv2FanDescription, atEnvMonv2FanLowerThreshold,
atEnvMonv2FanCurrentSpeed }
STATUS current
DESCRIPTION
"A notification generated when the monitored speed of a fan
returns to an acceptable value, the fan
having previously been in an alarm condition."
::= { atEnvMonv2Notifications 2 }
atEnvMonv2VoltAlarmSetNotify NOTIFICATION-TYPE
OBJECTS { atEnvMonv2VoltageStackMemberId, atEnvMonv2VoltageBoardIndex, atEnvMonv2VoltageIndex, atEnvMonv2VoltageDescription, atEnvMonv2VoltageUpperThreshold,
atEnvMonv2VoltageLowerThreshold, atEnvMonv2VoltageCurrent }
STATUS current
DESCRIPTION
"A notification generated when the voltage of a monitored
voltage rail goes out of tolerance, either by
dropping below its lower threshold, or exceeding
its upper threshold."
::= { atEnvMonv2Notifications 3 }
atEnvMonv2VoltAlarmClearedNotify NOTIFICATION-TYPE
OBJECTS { atEnvMonv2VoltageStackMemberId, atEnvMonv2VoltageBoardIndex, atEnvMonv2VoltageIndex, atEnvMonv2VoltageDescription, atEnvMonv2VoltageUpperThreshold,
atEnvMonv2VoltageLowerThreshold, atEnvMonv2VoltageCurrent }
STATUS current
DESCRIPTION
"A notification generated when the voltage of a monitored
voltage rail returns to an acceptable value,
having previously been in an alarm condition."
::= { atEnvMonv2Notifications 4 }
atEnvMonv2TempAlarmSetNotify NOTIFICATION-TYPE
OBJECTS { atEnvMonv2TemperatureStackMemberId, atEnvMonv2TemperatureBoardIndex, atEnvMonv2TemperatureIndex, atEnvMonv2TemperatureDescription, atEnvMonv2TemperatureUpperThreshold,
atEnvMonv2TemperatureCurrent }
STATUS current
DESCRIPTION
"A notification generated when a monitored temperature
exceeds its upper threshold."
::= { atEnvMonv2Notifications 5 }
atEnvMonv2TempAlarmClearedNotify NOTIFICATION-TYPE
OBJECTS { atEnvMonv2TemperatureStackMemberId, atEnvMonv2TemperatureBoardIndex, atEnvMonv2TemperatureIndex, atEnvMonv2TemperatureDescription, atEnvMonv2TemperatureUpperThreshold
}
STATUS current
DESCRIPTION
"A notification generated when a monitored temperature
returns to an acceptable value, having
previously been in an alarm condition."
::= { atEnvMonv2Notifications 6 }
atEnvMonv2PsbAlarmSetNotify NOTIFICATION-TYPE
OBJECTS { atEnvMonv2PsbSensorStackMemberId, atEnvMonv2PsbSensorBoardIndex, atEnvMonv2PsbSensorIndex, atEnvMonv2PsbSensorType, atEnvMonv2PsbSensorDescription
}
STATUS current
DESCRIPTION
"A notification generated when a monitored parameter of
a power supply bay device goes out of
tolerance."
::= { atEnvMonv2Notifications 7 }
atEnvMonv2PsbAlarmClearedNotify NOTIFICATION-TYPE
OBJECTS { atEnvMonv2PsbSensorStackMemberId, atEnvMonv2PsbSensorBoardIndex, atEnvMonv2PsbSensorIndex, atEnvMonv2PsbSensorType, atEnvMonv2PsbSensorDescription
}
STATUS current
DESCRIPTION
"A notification generated when a monitored parameter of
a power supply bay device returns to an
acceptable value, having previously been
in an alarm condition."
::= { atEnvMonv2Notifications 8 }
atEnvMonv2ContactInputOpenNotify NOTIFICATION-TYPE
OBJECTS { atEnvMonv2ContactInputStackMemberId, atEnvMonv2ContactInputBoardIndex, atEnvMonv2ContactInputIndex, atEnvMonv2ContactInputDescription
}
STATUS current
DESCRIPTION
"A notification generated when a monitored contact input opens."
::= { atEnvMonv2Notifications 9 }
atEnvMonv2ContactInputCloseNotify NOTIFICATION-TYPE
OBJECTS { atEnvMonv2ContactInputStackMemberId, atEnvMonv2ContactInputBoardIndex, atEnvMonv2ContactInputIndex, atEnvMonv2ContactInputDescription
}
STATUS current
DESCRIPTION
"A notification generated when a monitored contact input closes."
::= { atEnvMonv2Notifications 10 }
atEnvMonv2ExternalPSUAlarmSetNotify NOTIFICATION-TYPE
OBJECTS { atEnvMonv2ExternalPSUStackMemberId, atEnvMonv2ExternalPSUBoardIndex, atEnvMonv2ExternalPSUIndex, atEnvMonv2ExternalPSUDescription
}
STATUS current
DESCRIPTION
"A notification generated when supply potential of
a monitored external power supply is not present."
::= { atEnvMonv2Notifications 11 }
atEnvMonv2ExternalPSUAlarmClearedNotify NOTIFICATION-TYPE
OBJECTS { atEnvMonv2ExternalPSUStackMemberId, atEnvMonv2ExternalPSUBoardIndex, atEnvMonv2ExternalPSUIndex, atEnvMonv2ExternalPSUDescription
}
STATUS current
DESCRIPTION
"A notification generated when supply potential of
a monitored external power supply returns to an
acceptable value, having previously been in an
alarm condition."
::= { atEnvMonv2Notifications 12 }
atEnvMonv2TempCriticalSetNotify NOTIFICATION-TYPE
OBJECTS { atEnvMonv2TemperatureStackMemberId }
STATUS current
DESCRIPTION
"A notification generated when a monitored temperature
exceeds its upper threshold."
::= { atEnvMonv2Notifications 13 }
atEnvMonv2TempCriticalClearedNotify NOTIFICATION-TYPE
OBJECTS { atEnvMonv2TemperatureStackMemberId }
STATUS current
DESCRIPTION
"A notification generated when a monitored temperature
returns to an acceptable value, having
previously been in an alarm condition."
::= { atEnvMonv2Notifications 14 }
atEnvMonv2TempCriticalLevel1SetNotify NOTIFICATION-TYPE
OBJECTS { atEnvMonv2TemperatureStackMemberId }
STATUS current
DESCRIPTION
"A notification generated when a monitored temperature
exceeds the level 1 threshold."
::= { atEnvMonv2Notifications 15 }
atEnvMonv2TempCriticalLevel1ClearedNotify NOTIFICATION-TYPE
OBJECTS { atEnvMonv2TemperatureStackMemberId }
STATUS current
DESCRIPTION
"A notification generated when a monitored temperature
returns to an acceptable value, having previously been in
critical temperature level 1 condition."
::= { atEnvMonv2Notifications 16 }
atEnvMonv2TempCriticalLevel2SetNotify NOTIFICATION-TYPE
OBJECTS { atEnvMonv2TemperatureStackMemberId }
STATUS current
DESCRIPTION
"A notification generated when a monitored temperature
exceeds the level 2 threshold."
::= { atEnvMonv2Notifications 17 }
atEnvMonv2TempCriticalLevel2ClearedNotify NOTIFICATION-TYPE
OBJECTS { atEnvMonv2TemperatureStackMemberId }
STATUS current
DESCRIPTION
"A notification generated when a monitored temperature
returns to an acceptable value, having previously been in
critical temperature level 2 condition."
::= { atEnvMonv2Notifications 18 }
-- ---------------------------------------------------------- --
-- The Environment Monitoring Fan Table
-- ---------------------------------------------------------- --
atEnvMonv2FanTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtEnvMonv2FanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of information about fans installed in the device
that have their fan speeds monitored by environment
monitoring hardware."
::= { atEnvMonv2 1 }
atEnvMonv2FanEntry OBJECT-TYPE
SYNTAX AtEnvMonv2FanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The description, current speed, lower threshold speed and
current status of a fan."
INDEX { atEnvMonv2FanStackMemberId, atEnvMonv2FanBoardIndex, atEnvMonv2FanIndex }
::= { atEnvMonv2FanTable 1 }
AtEnvMonv2FanEntry ::=
SEQUENCE {
atEnvMonv2FanStackMemberId
Unsigned32,
atEnvMonv2FanBoardIndex
Unsigned32,
atEnvMonv2FanIndex
Unsigned32,
atEnvMonv2FanDescription
DisplayStringUnsized,
atEnvMonv2FanCurrentSpeed
Unsigned32,
atEnvMonv2FanLowerThreshold
Unsigned32,
atEnvMonv2FanStatus
INTEGER
}
atEnvMonv2FanStackMemberId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the stack member hosting this fan. For a chassis
switch, it corresponds to the card ID of the controller that
is monitoring the chassis hardware, e.g. 5 or 6. In a VCStack
Plus, the second chassis uses controller IDs 17 or 18. Refer
to chassisMappingTable for more details."
::= { atEnvMonv2FanEntry 1 }
atEnvMonv2FanBoardIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the board hosting this fan in the board table."
::= { atEnvMonv2FanEntry 2 }
atEnvMonv2FanIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numeric identifier of this fan on its host board."
::= { atEnvMonv2FanEntry 3 }
atEnvMonv2FanDescription OBJECT-TYPE
SYNTAX DisplayStringUnsized (SIZE (0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of this fan."
::= { atEnvMonv2FanEntry 4 }
atEnvMonv2FanCurrentSpeed OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current speed of this fan in revolutions per
minute."
::= { atEnvMonv2FanEntry 5 }
atEnvMonv2FanLowerThreshold OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum acceptable speed of the fan in revolutions
per minute."
::= { atEnvMonv2FanEntry 6 }
atEnvMonv2FanStatus OBJECT-TYPE
SYNTAX INTEGER
{
failed(1),
good(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication of whether this fan is currently in an
alarm condition. A value of 'failed(1)' indicates that its
current speed is too low, 'good(2)' indicates that the
current speed is acceptable."
::= { atEnvMonv2FanEntry 7 }
-- ---------------------------------------------------------- --
-- The Environment Monitoring Voltage Table
-- ---------------------------------------------------------- --
atEnvMonv2VoltageTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtEnvMonv2VoltageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of information about voltage rails in the device
that are monitored by environment monitoring hardware."
::= { atEnvMonv2 2 }
atEnvMonv2VoltageEntry OBJECT-TYPE
SYNTAX AtEnvMonv2VoltageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The description, current value, upper & lower threshold
settings and current status of a voltage rail."
INDEX { atEnvMonv2VoltageStackMemberId, atEnvMonv2VoltageBoardIndex, atEnvMonv2VoltageIndex }
::= { atEnvMonv2VoltageTable 1 }
AtEnvMonv2VoltageEntry ::=
SEQUENCE {
atEnvMonv2VoltageStackMemberId
Unsigned32,
atEnvMonv2VoltageBoardIndex
Unsigned32,
atEnvMonv2VoltageIndex
Unsigned32,
atEnvMonv2VoltageDescription
DisplayStringUnsized,
atEnvMonv2VoltageCurrent
INTEGER,
atEnvMonv2VoltageUpperThreshold
INTEGER,
atEnvMonv2VoltageLowerThreshold
INTEGER,
atEnvMonv2VoltageStatus
INTEGER
}
atEnvMonv2VoltageStackMemberId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the stack member hosting this voltage sensor. For
a chassis switch, it corresponds to the card ID of the controller
that is monitoring the chassis hardware, e.g. 5 or 6. In a VCStack
Plus, the second chassis uses controller IDs 17 or 18. Refer to
chassisMappingTable for more details."
::= { atEnvMonv2VoltageEntry 1 }
atEnvMonv2VoltageBoardIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the board hosting this voltage sensor in the board table."
::= { atEnvMonv2VoltageEntry 2 }
atEnvMonv2VoltageIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numeric identifier of this voltage rail on its host board."
::= { atEnvMonv2VoltageEntry 3 }
atEnvMonv2VoltageDescription OBJECT-TYPE
SYNTAX DisplayStringUnsized (SIZE (0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of this voltage rail."
::= { atEnvMonv2VoltageEntry 4 }
atEnvMonv2VoltageCurrent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current reading of this voltage rail in millivolts."
::= { atEnvMonv2VoltageEntry 5 }
atEnvMonv2VoltageUpperThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum acceptable reading of this voltage rail in millivolts."
::= { atEnvMonv2VoltageEntry 6 }
atEnvMonv2VoltageLowerThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum acceptable reading of this voltage rail in millivolts."
::= { atEnvMonv2VoltageEntry 7 }
atEnvMonv2VoltageStatus OBJECT-TYPE
SYNTAX INTEGER
{
outOfRange(1),
inRange(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication of whether this voltage rail is currently
in an alarm condition. A value of 'outOfRange' indicates that
its current reading is outside its threshold range,
'inRange' indicates that the current reading is acceptable."
::= { atEnvMonv2VoltageEntry 8 }
-- ---------------------------------------------------------- --
-- The Environment Monitoring Temperature Table
-- ---------------------------------------------------------- --
atEnvMonv2TemperatureTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtEnvMonv2TemperatureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of information about temperature sensors in the device
that are monitored by environment monitoring hardware."
::= { atEnvMonv2 3 }
atEnvMonv2TemperatureEntry OBJECT-TYPE
SYNTAX AtEnvMonv2TemperatureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The description, current value, upper threshold setting
and current status of a temperature sensor."
INDEX { atEnvMonv2TemperatureStackMemberId, atEnvMonv2TemperatureBoardIndex, atEnvMonv2TemperatureIndex }
::= { atEnvMonv2TemperatureTable 1 }
AtEnvMonv2TemperatureEntry ::=
SEQUENCE {
atEnvMonv2TemperatureStackMemberId
Unsigned32,
atEnvMonv2TemperatureBoardIndex
Unsigned32,
atEnvMonv2TemperatureIndex
Unsigned32,
atEnvMonv2TemperatureDescription
DisplayStringUnsized,
atEnvMonv2TemperatureCurrent
INTEGER,
atEnvMonv2TemperatureUpperThreshold
INTEGER,
atEnvMonv2TemperatureStatus
INTEGER
}
atEnvMonv2TemperatureStackMemberId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the stack member hosting this temperature sensor. For
a chassis switch, it corresponds to the card ID of the controller
that is monitoring the chassis hardware, e.g. 5 or 6. In a VCStack
Plus, the second chassis uses controller IDs 17 or 18. Refer to
chassisMappingTable for more details."
::= { atEnvMonv2TemperatureEntry 1 }
atEnvMonv2TemperatureBoardIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the board hosting this temperature sensor in the board table."
::= { atEnvMonv2TemperatureEntry 2 }
atEnvMonv2TemperatureIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numeric identifier of this temperature sensor on its host board."
::= { atEnvMonv2TemperatureEntry 3 }
atEnvMonv2TemperatureDescription OBJECT-TYPE
SYNTAX DisplayStringUnsized (SIZE (0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of this temperature sensor."
::= { atEnvMonv2TemperatureEntry 4 }
atEnvMonv2TemperatureCurrent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current reading of this temperature sensor in tenths of a degree Celsius."
::= { atEnvMonv2TemperatureEntry 5 }
atEnvMonv2TemperatureUpperThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum acceptable reading of this temperature
sensor in tenths of a degree Celsius."
::= { atEnvMonv2TemperatureEntry 6 }
atEnvMonv2TemperatureStatus OBJECT-TYPE
SYNTAX INTEGER
{
outOfRange(1),
inRange(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication of whether this temperature sensor is
currently in an alarm condition. A value of 'outOfRange'
indicates that its current reading is outside its threshold
range, 'inRange' indicates that the current reading is
acceptable."
::= { atEnvMonv2TemperatureEntry 7 }
-- ---------------------------------------------------------- --
-- The Environment Monitoring Power Supply Bay Device Table
-- ---------------------------------------------------------- --
atEnvMonv2PsbObjects OBJECT IDENTIFIER ::= { atEnvMonv2 4 }
atEnvMonv2PsbTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtEnvMonv2PsbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of information about power supply bays in the system and
any devices that are installed."
::= { atEnvMonv2PsbObjects 1 }
atEnvMonv2PsbEntry OBJECT-TYPE
SYNTAX AtEnvMonv2PsbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The description and current status of a power supply
bay device."
INDEX { atEnvMonv2PsbHostStackMemberId, atEnvMonv2PsbHostBoardIndex, atEnvMonv2PsbHostSlotIndex }
::= { atEnvMonv2PsbTable 1 }
AtEnvMonv2PsbEntry ::=
SEQUENCE {
atEnvMonv2PsbHostStackMemberId
Unsigned32,
atEnvMonv2PsbHostBoardIndex
Unsigned32,
atEnvMonv2PsbHostSlotIndex
Unsigned32,
atEnvMonv2PsbHeldBoardIndex
Unsigned32,
atEnvMonv2PsbHeldBoardId
OBJECT IDENTIFIER,
atEnvMonv2PsbDescription
DisplayStringUnsized
}
atEnvMonv2PsbHostStackMemberId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the stack member hosting this power supply bay. For
a chassis switch, it corresponds to the card ID of the controller
that is monitoring the chassis hardware, e.g. 5 or 6. In a VCStack
Plus, the second chassis uses controller IDs 17 or 18. Refer to
chassisMappingTable for more details."
::= { atEnvMonv2PsbEntry 1 }
atEnvMonv2PsbHostBoardIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the board hosting this power supply bay in the board table."
::= { atEnvMonv2PsbEntry 2 }
atEnvMonv2PsbHostSlotIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of this power supply bay on its host board.
This index is fixed for each slot, on each type of board."
::= { atEnvMonv2PsbEntry 3 }
atEnvMonv2PsbHeldBoardIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of a board installed in this power supply bay.
This value corresponds to atEnvMonv2PsbSensorBoardIndex for
each sensor on this board. A value of 0 indicates that a
board is is either not present or not supported."
::= { atEnvMonv2PsbEntry 4 }
atEnvMonv2PsbHeldBoardId OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of board installed in this power supply bay. The
values of this object are taken from the pprXxx object IDs
under the boards sub-tree in the parent MIB. A value of 0
indicates that a board is either not present or not
supported."
::= { atEnvMonv2PsbEntry 5 }
atEnvMonv2PsbDescription OBJECT-TYPE
SYNTAX DisplayStringUnsized (SIZE (0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of this power supply bay."
::= { atEnvMonv2PsbEntry 6 }
atEnvMonv2PsbSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtEnvMonv2PsbSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of information about environment monitoring sensors
on devices installed in power supply bays."
::= { atEnvMonv2PsbObjects 2 }
atEnvMonv2PsbSensorEntry OBJECT-TYPE
SYNTAX AtEnvMonv2PsbSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The description and current status of a device installed
in a power supply bay."
INDEX { atEnvMonv2PsbSensorStackMemberId, atEnvMonv2PsbSensorBoardIndex, atEnvMonv2PsbSensorIndex }
::= { atEnvMonv2PsbSensorTable 1 }
AtEnvMonv2PsbSensorEntry ::=
SEQUENCE {
atEnvMonv2PsbSensorStackMemberId
Unsigned32,
atEnvMonv2PsbSensorBoardIndex
Unsigned32,
atEnvMonv2PsbSensorIndex
Unsigned32,
atEnvMonv2PsbSensorType
AtEnvMonv2PsbSensorType,
atEnvMonv2PsbSensorDescription
DisplayStringUnsized,
atEnvMonv2PsbSensorStatus
INTEGER,
atEnvMonv2PsbSensorReading
INTEGER
}
atEnvMonv2PsbSensorStackMemberId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the stack member hosting this sensor. For a
chassis switch, it corresponds to the card ID of the controller
that is monitoring the chassis hardware, e.g. 5 or 6. In a VCStack
Plus, the second chassis uses controller IDs 17 or 18. Refer to
chassisMappingTable for more details."
::= { atEnvMonv2PsbSensorEntry 1 }
atEnvMonv2PsbSensorBoardIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the board hosting this sensor in the board table."
::= { atEnvMonv2PsbSensorEntry 2 }
atEnvMonv2PsbSensorIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of this power supply bay environmental sensor on
its host board."
::= { atEnvMonv2PsbSensorEntry 3 }
atEnvMonv2PsbSensorType OBJECT-TYPE
SYNTAX AtEnvMonv2PsbSensorType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of environmental variable this sensor detects."
::= { atEnvMonv2PsbSensorEntry 4 }
atEnvMonv2PsbSensorDescription OBJECT-TYPE
SYNTAX DisplayStringUnsized (SIZE (0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of this power supply bay environmental sensor."
::= { atEnvMonv2PsbSensorEntry 5 }
atEnvMonv2PsbSensorStatus OBJECT-TYPE
SYNTAX INTEGER
{
failed(1),
good(2),
notPowered(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication of whether this environmental sensor is currently
in an alarm condition. A value of 'failed(1)' indicates that
the device is in a failure condition, 'good(2)' indicates that
the device is functioning normally."
::= { atEnvMonv2PsbSensorEntry 6 }
atEnvMonv2PsbSensorReading OBJECT-TYPE
SYNTAX INTEGER
{
no(1),
yes(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication of whether this environmental sensor is
currently reading a value for the monitored device. A value
of 'no' indicates that there is no current reading, 'yes' indicates
that the monitored device is supplying a reading."
::= { atEnvMonv2PsbSensorEntry 7 }
-- ---------------------------------------------------------- --
-- The Environment Monitoring SNMP Trap Objects (Deprecated)
-- ---------------------------------------------------------- --
atEnvMonv2Traps OBJECT IDENTIFIER ::= { atEnvMonv2 5 }
atEnvMonv2FanAlarmSetEvent NOTIFICATION-TYPE
OBJECTS { atEnvMonv2FanStackMemberId, atEnvMonv2FanBoardIndex, atEnvMonv2FanIndex, atEnvMonv2FanDescription, atEnvMonv2FanLowerThreshold,
atEnvMonv2FanCurrentSpeed }
STATUS deprecated
DESCRIPTION
"A trap generated when the monitored speed of a fan
drops below its lower threshold."
::= { atEnvMonv2Traps 1 }
atEnvMonv2FanAlarmClearedEvent NOTIFICATION-TYPE
OBJECTS { atEnvMonv2FanStackMemberId, atEnvMonv2FanBoardIndex, atEnvMonv2FanIndex, atEnvMonv2FanDescription, atEnvMonv2FanLowerThreshold,
atEnvMonv2FanCurrentSpeed }
STATUS deprecated
DESCRIPTION
"A trap generated when the monitored speed of a fan
returns to an acceptable value, the fan
having previously been in an alarm condition."
::= { atEnvMonv2Traps 2 }
atEnvMonv2VoltAlarmSetEvent NOTIFICATION-TYPE
OBJECTS { atEnvMonv2VoltageStackMemberId, atEnvMonv2VoltageBoardIndex, atEnvMonv2VoltageIndex, atEnvMonv2VoltageDescription, atEnvMonv2VoltageUpperThreshold,
atEnvMonv2VoltageLowerThreshold, atEnvMonv2VoltageCurrent }
STATUS deprecated
DESCRIPTION
"A trap generated when the voltage of a monitored
voltage rail goes out of tolerance, either by
dropping below its lower threshold, or exceeding
its upper threshold."
::= { atEnvMonv2Traps 3 }
atEnvMonv2VoltAlarmClearedEvent NOTIFICATION-TYPE
OBJECTS { atEnvMonv2VoltageStackMemberId, atEnvMonv2VoltageBoardIndex, atEnvMonv2VoltageIndex, atEnvMonv2VoltageDescription, atEnvMonv2VoltageUpperThreshold,
atEnvMonv2VoltageLowerThreshold, atEnvMonv2VoltageCurrent }
STATUS deprecated
DESCRIPTION
"A trap generated when the voltage of a monitored
voltage rail returns to an acceptable value,
having previously been in an alarm condition."
::= { atEnvMonv2Traps 4 }
atEnvMonv2TempAlarmSetEvent NOTIFICATION-TYPE
OBJECTS { atEnvMonv2TemperatureStackMemberId, atEnvMonv2TemperatureBoardIndex, atEnvMonv2TemperatureIndex, atEnvMonv2TemperatureDescription, atEnvMonv2TemperatureUpperThreshold,
atEnvMonv2TemperatureCurrent }
STATUS deprecated
DESCRIPTION
"A trap generated when a monitored temperature
exceeds its upper threshold."
::= { atEnvMonv2Traps 5 }
atEnvMonv2TempAlarmClearedEvent NOTIFICATION-TYPE
OBJECTS { atEnvMonv2TemperatureStackMemberId, atEnvMonv2TemperatureBoardIndex, atEnvMonv2TemperatureIndex, atEnvMonv2TemperatureDescription, atEnvMonv2TemperatureUpperThreshold
}
STATUS deprecated
DESCRIPTION
"A trap generated when a monitored temperature
returns to an acceptable value, having
previously been in an alarm condition."
::= { atEnvMonv2Traps 6 }
atEnvMonv2PsbAlarmSetEvent NOTIFICATION-TYPE
OBJECTS { atEnvMonv2PsbSensorStackMemberId, atEnvMonv2PsbSensorBoardIndex, atEnvMonv2PsbSensorIndex, atEnvMonv2PsbSensorType, atEnvMonv2PsbSensorDescription
}
STATUS deprecated
DESCRIPTION
"A trap generated when a monitored parameter of
a power supply bay device goes out of
tolerance."
::= { atEnvMonv2Traps 7 }
atEnvMonv2PsbAlarmClearedEvent NOTIFICATION-TYPE
OBJECTS { atEnvMonv2PsbSensorStackMemberId, atEnvMonv2PsbSensorBoardIndex, atEnvMonv2PsbSensorIndex, atEnvMonv2PsbSensorType, atEnvMonv2PsbSensorDescription
}
STATUS deprecated
DESCRIPTION
"A trap generated when a monitored parameter of
a power supply bay device returns to an
acceptable value, having previously been
in an alarm condition."
::= { atEnvMonv2Traps 8 }
-- ---------------------------------------------------------- --
-- The Environment Monitoring Fault LED Table
-- ---------------------------------------------------------- --
atEnvMonv2FaultLedTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtEnvMonv2FaultLedEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of information detailing any LED fault indications on
the device."
::= { atEnvMonv2 6 }
atEnvMonv2FaultLedEntry OBJECT-TYPE
SYNTAX AtEnvMonv2FaultLedEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry pertaining to a given fault LED."
INDEX { atEnvMonv2FaultLedStackMemberId }
::= { atEnvMonv2FaultLedTable 1 }
AtEnvMonv2FaultLedEntry ::=
SEQUENCE {
atEnvMonv2FaultLedStackMemberId
Unsigned32,
atEnvMonv2FaultLed1Flash
INTEGER,
atEnvMonv2FaultLed2Flashes
INTEGER,
atEnvMonv2FaultLed3Flashes
INTEGER,
atEnvMonv2FaultLed4Flashes
INTEGER,
atEnvMonv2FaultLed5Flashes
INTEGER,
atEnvMonv2FaultLed6Flashes
INTEGER
}
atEnvMonv2FaultLedStackMemberId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the stack member hosting this fault LED. For a
chassis switch, it corresponds to the card ID of the controller
that is monitoring the chassis hardware, e.g. 5 or 6. In a VCStack
Plus, the second chassis uses controller IDs 17 or 18. Refer to
chassisMappingTable for more details."
::= { atEnvMonv2FaultLedEntry 1 }
atEnvMonv2FaultLed1Flash OBJECT-TYPE
SYNTAX INTEGER
{
heatsinkFanFailure(1),
noFault(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates whether a fault LED is currently showing
a system failure by flashing once. It indicates that one or
more heatsink fans have failed, or are operating below the
recommended speed."
::= { atEnvMonv2FaultLedEntry 2 }
atEnvMonv2FaultLed2Flashes OBJECT-TYPE
SYNTAX INTEGER
{
chassisFanFailure(1),
noFault(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates whether a fault LED is currently showing
a system failure by flashing twice. It indicates that one or
both of the chassis fans are not installed, or the fans are
operating below the recommended speed."
::= { atEnvMonv2FaultLedEntry 3 }
atEnvMonv2FaultLed3Flashes OBJECT-TYPE
SYNTAX INTEGER
{
sensorFailure(1),
noFault(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates whether a fault LED is currently showing
a system failure by flashing three times. It indicates that the
ability to monitor temperature or fans has failed."
::= { atEnvMonv2FaultLedEntry 4 }
atEnvMonv2FaultLed4Flashes OBJECT-TYPE
SYNTAX INTEGER
{
xemInitialisationFailure(1),
noFault(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates whether a fault LED is currently showing
a system failure by flashing four times. It indicates that an
XEM failed to initialise or is incompatible."
::= { atEnvMonv2FaultLedEntry 5 }
atEnvMonv2FaultLed5Flashes OBJECT-TYPE
SYNTAX INTEGER { noFault(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates whether a fault LED is currently showing
a system failure by flashing five times. This flashing
sequence is not currently in use."
::= { atEnvMonv2FaultLedEntry 6 }
atEnvMonv2FaultLed6Flashes OBJECT-TYPE
SYNTAX INTEGER
{
temperatureFailure(1),
noFault(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates whether a fault LED is currently showing
a system failure by flashing six times. It indicates that the
device's temperature has exceeded the recommended threshold."
::= { atEnvMonv2FaultLedEntry 7 }
-- ---------------------------------------------------------- --
-- The Environment Monitoring Contact Input Table
-- ---------------------------------------------------------- --
atEnvMonv2ContactInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtEnvMonv2ContactInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of information about contact inputs available in the
device that are monitored by environment monitoring hardware."
::= { atEnvMonv2 7 }
atEnvMonv2ContactInputEntry OBJECT-TYPE
SYNTAX AtEnvMonv2ContactInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The description and current state of a contact input."
INDEX { atEnvMonv2ContactInputStackMemberId, atEnvMonv2ContactInputBoardIndex, atEnvMonv2ContactInputIndex }
::= { atEnvMonv2ContactInputTable 1 }
AtEnvMonv2ContactInputEntry ::=
SEQUENCE {
atEnvMonv2ContactInputStackMemberId
Unsigned32,
atEnvMonv2ContactInputBoardIndex
Unsigned32,
atEnvMonv2ContactInputIndex
Unsigned32,
atEnvMonv2ContactInputDescription
DisplayStringUnsized,
atEnvMonv2ContactInputState
INTEGER
}
atEnvMonv2ContactInputStackMemberId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the stack member hosting this contact input."
::= { atEnvMonv2ContactInputEntry 1 }
atEnvMonv2ContactInputBoardIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the board hosting this contact input in the board table."
::= { atEnvMonv2ContactInputEntry 2 }
atEnvMonv2ContactInputIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numeric identifier of this contact input on its host board."
::= { atEnvMonv2ContactInputEntry 3 }
atEnvMonv2ContactInputDescription OBJECT-TYPE
SYNTAX DisplayStringUnsized (SIZE (0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of this contact input."
::= { atEnvMonv2ContactInputEntry 4 }
atEnvMonv2ContactInputState OBJECT-TYPE
SYNTAX INTEGER
{
closed(1),
open(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication of whether this contact input is currently
open or closed."
::= { atEnvMonv2ContactInputEntry 5 }
-- ---------------------------------------------------------- --
-- The Environment Monitoring Contact Output Table
-- ---------------------------------------------------------- --
atEnvMonv2ContactOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtEnvMonv2ContactOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of information about contact outputs available in the
device that are managed by environment monitoring hardware."
::= { atEnvMonv2 8 }
atEnvMonv2ContactOutputEntry OBJECT-TYPE
SYNTAX AtEnvMonv2ContactOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The description and current state of a contact output."
INDEX { atEnvMonv2ContactOutputStackMemberId, atEnvMonv2ContactOutputBoardIndex, atEnvMonv2ContactOutputIndex }
::= { atEnvMonv2ContactOutputTable 1 }
AtEnvMonv2ContactOutputEntry ::=
SEQUENCE {
atEnvMonv2ContactOutputStackMemberId
Unsigned32,
atEnvMonv2ContactOutputBoardIndex
Unsigned32,
atEnvMonv2ContactOutputIndex
Unsigned32,
atEnvMonv2ContactOutputDescription
DisplayStringUnsized,
atEnvMonv2ContactOutputState
INTEGER
}
atEnvMonv2ContactOutputStackMemberId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the stack member hosting this contact output."
::= { atEnvMonv2ContactOutputEntry 1 }
atEnvMonv2ContactOutputBoardIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the board hosting this contact output in the board table."
::= { atEnvMonv2ContactOutputEntry 2 }
atEnvMonv2ContactOutputIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numeric identifier of this contact output on its host board."
::= { atEnvMonv2ContactOutputEntry 3 }
atEnvMonv2ContactOutputDescription OBJECT-TYPE
SYNTAX DisplayStringUnsized (SIZE (0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of this contact output."
::= { atEnvMonv2ContactOutputEntry 4 }
atEnvMonv2ContactOutputState OBJECT-TYPE
SYNTAX INTEGER
{
closed(1),
open(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication of whether this contact output is currently
open or closed."
::= { atEnvMonv2ContactOutputEntry 5 }
-- ---------------------------------------------------------- --
-- The Environment Monitoring External Power Supply Status Table
-- ---------------------------------------------------------- --
atEnvMonv2ExternalPSUTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtEnvMonv2ExternalPSUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of external PSU status."
::= { atEnvMonv2 9 }
atEnvMonv2ExternalPSUEntry OBJECT-TYPE
SYNTAX AtEnvMonv2ExternalPSUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The description and current status of an external power supply."
INDEX { atEnvMonv2ExternalPSUStackMemberId, atEnvMonv2ExternalPSUBoardIndex, atEnvMonv2ExternalPSUIndex }
::= { atEnvMonv2ExternalPSUTable 1 }
AtEnvMonv2ExternalPSUEntry ::=
SEQUENCE {
atEnvMonv2ExternalPSUStackMemberId
Unsigned32,
atEnvMonv2ExternalPSUBoardIndex
Unsigned32,
atEnvMonv2ExternalPSUIndex
Unsigned32,
atEnvMonv2ExternalPSUDescription
DisplayStringUnsized,
atEnvMonv2ExternalPSUState
INTEGER
}
atEnvMonv2ExternalPSUStackMemberId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the stack member hosting this external PSU."
::= { atEnvMonv2ExternalPSUEntry 1 }
atEnvMonv2ExternalPSUBoardIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the board hosting this external PSU in the board table."
::= { atEnvMonv2ExternalPSUEntry 2 }
atEnvMonv2ExternalPSUIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numeric identifier of this external PSU on its host board."
::= { atEnvMonv2ExternalPSUEntry 3 }
atEnvMonv2ExternalPSUDescription OBJECT-TYPE
SYNTAX DisplayStringUnsized (SIZE (0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of this external PSU."
::= { atEnvMonv2ExternalPSUEntry 4 }
atEnvMonv2ExternalPSUState OBJECT-TYPE
SYNTAX INTEGER
{
failed(1),
good(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication of whether the supply potential of the external power
supply is present or not. A value of 'failed(1)' indicates that
no power is being received on this input, 'good(2)' indicates that
this input is receiving power from the external power supply."
::= { atEnvMonv2ExternalPSUEntry 5 }
END
--
-- at-envmonv2.mib
--