BENU-CHASSIS-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Integer32,Unsigned32,TimeTicks
FROM SNMPv2-SMI
ifIndex,ifDescr,ifType,ifAdminStatus,ifOperStatus
FROM IF-MIB
benuPlatform
FROM BENU-PLATFORM-MIB
DisplayString
FROM SNMPv2-TC;
benuChassisMIB MODULE-IDENTITY
LAST-UPDATED "201611180000Z" -- 18 November 2016
ORGANIZATION "Benu Networks"
CONTACT-INFO "Benu Networks Inc,
300 Concord Road,
Billerca MA 01821
Email: support@benunets.com"
DESCRIPTION
"Initial creation MIB module for Benu Networks Chassis.
Copyright (C) 2001, 2008 by Benu Networks, Inc.
All rights reserved."
REVISION "201611180000Z" -- 18 November 2016
DESCRIPTION
"Added xMEG card type"
REVISION "201610140000Z" -- 14 October 2016
DESCRIPTION
"Changes for xMEG platform"
REVISION "201601260000Z" -- 26 January 2016
DESCRIPTION
"Added benuCardIfVirtualType"
REVISION "201510140000Z" -- 14 October 2015
DESCRIPTION
"Added benuPowerSupplyTable"
REVISION "201501270000Z" -- 27 January 2015
DESCRIPTION
"Updated benuChassisId from read-write to read-only.
Also, updated the description appropriately."
REVISION "201501050000Z" -- 05 January 2015
DESCRIPTION
"Updated notification assignments to comply with standards (RFC 2578)."
REVISION "201411140000Z" -- 14 November 2014
DESCRIPTION
"changed benuChassisNotifObjects type to scalar (2 to 0)"
REVISION "201406270000Z"
DESCRIPTION
"Added new encapsulation column in Card interface table"
REVISION "201311250000Z"
DESCRIPTION
"Added Fan Table "
REVISION "201212120000Z" -- 12 December 2012
DESCRIPTION
"Initial creation MIB module for Benu Networks Chassis"
::= { benuPlatform 1 }
benuChassisMIBObjects OBJECT IDENTIFIER ::= { benuChassisMIB 1 }
benuChassisNotifObjects OBJECT IDENTIFIER ::= { benuChassisMIB 0 }
benuChassisNotifVariables OBJECT IDENTIFIER ::= { benuChassisMIB 2 }
-- MIB contains five groups
benuChassisInfo OBJECT IDENTIFIER ::= { benuChassisMIBObjects 1 }
benuCardInfo OBJECT IDENTIFIER ::= { benuChassisMIBObjects 2 }
benuCardIfInfo OBJECT IDENTIFIER ::= { benuChassisMIBObjects 3 }
benuSensorInfo OBJECT IDENTIFIER ::= { benuChassisMIBObjects 4 }
benuChassisGeneralInfo OBJECT IDENTIFIER ::= { benuChassisMIBObjects 5 }
benuFanInfo OBJECT IDENTIFIER ::= { benuChassisMIBObjects 6 }
benuPowerSupplyInfo OBJECT IDENTIFIER ::= { benuChassisMIBObjects 7 }
--
-- chassis group information.
--
benuChassisType OBJECT-TYPE
SYNTAX INTEGER {
meg100(1),
meg400(2),
meg1200(3),
meg50(4),
xMEG100(5),
xMEG10(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chassis type."
::= { benuChassisInfo 1 }
benuChassisHwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chassis hardware revision level, or an empty
string if unavailable."
::= { benuChassisInfo 2 }
benuChassisId OBJECT-TYPE -- Serial Number
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique ID string. Defaults to chassis serial
number if available, otherwise empty"
::= { benuChassisInfo 3 }
benuChassisNumOfSlots OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of slots in this chassis, or -1
if neither applicable nor determinable."
::= { benuChassisInfo 4 }
benuChassisPowerTrapEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls SNMP traps for chassis Power Failure.
If its value is set to enabled(1), then traps
are generated. If the value is disabled(2), then traps
are not generated.
By default, this object has the value enabled(1).
"
DEFVAL { enabled }
::= { benuChassisInfo 5 }
benuChassisFanTrapEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls SNMP traps for chassis Fan Failure.
If its value is set to enabled(1), then traps
are generated. If the value is disabled(2), then traps
are not generated.
By default, this object has the value enabled(1).
"
DEFVAL { enabled }
::= { benuChassisInfo 6 }
benuChassisSensorTrapEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls SNMP traps for chassis senor Failure.
If its value is set to enabled(1), then traps
are generated. If the value is disabled(2), then traps
are not generated.
By default, this object has the value enabled(1).
"
DEFVAL { enabled }
::= { benuChassisInfo 7 }
benuSysUpTimeAtLastChassisChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time (in hundredths of a second) from the last
cold start to the last change in the chassis'
configuration. This value will be updated
whenever the chassis experiences a change
in the count, type, or slot position of
a card in cardTable."
::= { benuChassisInfo 8 }
--
-- The Benu Card Table
--
benuCardTable OBJECT-TYPE
SYNTAX SEQUENCE OF BenuCardEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Chassis card table."
::= { benuCardInfo 1 }
benuCardEntry OBJECT-TYPE
SYNTAX BenuCardEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Chassis card table."
INDEX { benuCardIndex }
::= { benuCardTable 1 }
BenuCardEntry ::= SEQUENCE {
benuCardIndex Unsigned32,
benuCardType INTEGER,
benuCardDescr DisplayString,
benuCardSerial DisplayString,
benuCardPartNumber DisplayString,
benuCardHwVersion DisplayString,
benuCardSwVersion DisplayString,
benuCardSlotNumber Integer32,
benuCardRamSize Integer32,
benuCardPrimaryDiskSize Integer32,
benuCardSecondaryDiskSize Integer32,
benuCardOperStatus INTEGER
}
benuCardIndex OBJECT-TYPE
SYNTAX Unsigned32(1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index into cardTable (not physical chassis
slot number)."
::= { benuCardEntry 1 }
benuCardType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
rsm(1),
switchFabric(2),
shelfmgr(3),
seFP(4),
inputOutputCard(5),
switchMesh(6),
xmeg(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Functional type of this card."
::= { benuCardEntry 2 }
benuCardDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Text description of this card."
::= { benuCardEntry 3 }
benuCardSerial OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number of this card, or zero if
unavailable."
::= { benuCardEntry 4 }
benuCardPartNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The part number of this card, or an
empty string if unavailable."
::= { benuCardEntry 5 }
benuCardHwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hardware revision level of this card, or an
empty string if unavailable."
::= { benuCardEntry 6 }
benuCardSwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Version of the firmware or microcode
installed on this card, or an empty string if
unavailable."
::= { benuCardEntry 7 }
benuCardSlotNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number relative to the containing card or
chassis, or -1 if neither applicable nor
determinable."
::= { benuCardEntry 8 }
benuCardRamSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of kilobytes of DRAM.
A value -1 means not available / not applicable
A value 0 means internal error."
::= { benuCardEntry 9 }
benuCardPrimaryDiskSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of kilobytes of Disk Memory (SATA or Hard Disk).
A value -1 means not available / not applicable.
A value 0 means internal error."
::= { benuCardEntry 10 }
benuCardSecondaryDiskSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of kilobytes of Disk Memory (SATA or Hard Disk).
A value -1 means not available / not applicable.
A value 0 means internal error."
::= { benuCardEntry 11 }
benuCardOperStatus OBJECT-TYPE
SYNTAX INTEGER {
notSpecified(1),
up(2),
down(3),
standby(4),
rom(5),
flash(6),
diag(7),
boot(8),
config(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational status of the card.
cardOperStatus is up when a card is
recognized by the device and is enabled for
operation. cardOperStatus is down if the
card is not recognized by the device, or if
it is not enabled for operation.
cardOperStatus is standby if the card is
enabled and acting as a standby slave.
Intermediate stages (rom,flash,diag,boot,config)
are also exposed."
::= { benuCardEntry 12 }
--
-- The card Interface table
--
benuCardIfIndexTable OBJECT-TYPE
SYNTAX SEQUENCE OF BenuCardIfIndexEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Chassis card Interface table."
::= { benuCardIfInfo 1 }
benuCardIfIndexEntry OBJECT-TYPE
SYNTAX BenuCardIfIndexEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Chassis card table."
INDEX { benuCardIfIndex }
::= { benuCardIfIndexTable 1 }
BenuCardIfIndexEntry ::= SEQUENCE {
benuCardIfIndex Unsigned32,
benuCardIfName DisplayString,
benuCardIfPortNumber Integer32,
benuCardIfSlotNumber Integer32,
benuCardIfLinkUpDownEnable INTEGER,
benuCardIfPortType INTEGER,
benuCardIfBindName DisplayString,
benuCardIfEncapsulation DisplayString,
benuCardIfVirtualType INTEGER
}
benuCardIfIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"matches RFC1213 ifTable IfIndex"
::= { benuCardIfIndexEntry 1 }
benuCardIfName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"matches RFC1213 ifXTable IfName"
::= { benuCardIfIndexEntry 2 }
benuCardIfPortNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Chassis port number, unique per port on a
given card if available."
::= { benuCardIfIndexEntry 3 }
benuCardIfSlotNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical slot number of the card in
the Chassis which contains this interface"
::= { benuCardIfIndexEntry 4 }
benuCardIfLinkUpDownEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This enables and disables the sending of
the proprietary notifications 'benuLinkUpTrap'
and 'benuLinkDownTrap' that provide more
information than the standard link up and
link down notifications. By default, these
traps are disabled."
DEFVAL { disabled }
::= { benuCardIfIndexEntry 5 }
benuCardIfPortType OBJECT-TYPE
SYNTAX INTEGER {
none(0),
ethernet(1),
fastEthernet(2),
gigaEthernet(3),
tunnel(4),
ipGre(5),
vlan(6),
l2tp(7),
cable(8),
bridge(9),
ip(10),
multiBind(11),
p2p(12),
loopback(13),
multiBindLastResort(14),
lag(15),
max(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object is used to identify port types for
a given card."
::= { benuCardIfIndexEntry 6 }
benuCardIfBindName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"interface name which is bound to this port .
This string will be empty if there is no interface
bind to this port "
::= { benuCardIfIndexEntry 7 }
benuCardIfEncapsulation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The encapsulation method used by the port."
::= { benuCardIfIndexEntry 8 }
benuCardIfVirtualType OBJECT-TYPE
SYNTAX INTEGER {
physical(1),
virtual(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object is used to identify virtualized
interfaces."
::= { benuCardIfIndexEntry 9 }
-- The Sensor Table
benuSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF BenuSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Chassis card table."
::= { benuSensorInfo 1 }
benuSensorEntry OBJECT-TYPE
SYNTAX BenuSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Chassis card table."
INDEX { benuSensorCardIndex , benuSensorIndex }
::= { benuSensorTable 1 }
BenuSensorEntry ::= SEQUENCE {
benuSensorCardIndex Unsigned32,
benuSensorIndex Unsigned32,
benuSensorName DisplayString,
benuSensorType INTEGER,
benuSensorValue Integer32,
benuSensorMinThresh Integer32,
benuSensorMaxThresh Integer32,
benuSensorState INTEGER,
benuSensorId Integer32
}
benuSensorCardIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"cardIndex of the card in the Chassis cardTable
which contains this sensor."
::= { benuSensorEntry 1 }
benuSensorIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index into sensorTable."
::= { benuSensorEntry 2 }
benuSensorName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the sensor."
::= { benuSensorEntry 3 }
benuSensorType OBJECT-TYPE
SYNTAX INTEGER {
other(0),
temparature(1),
voltage(2),
electicCurrent(3),
fan(4),
power(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type of the sensor."
::= { benuSensorEntry 4 }
benuSensorValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Value of this sensor.
The unit types for different type of sensors:
temparature -- celcius
Fan -- rpm
Volatage -- volts
Electric Current -- amperes
Power -- watts "
::= { benuSensorEntry 5 }
benuSensorMinThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum threshold for this sensor."
::= { benuSensorEntry 6 }
benuSensorMaxThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum threshold for this sensor."
::= { benuSensorEntry 7 }
benuSensorState OBJECT-TYPE
SYNTAX INTEGER {
other(0),
normal(1),
critical(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "State of the sensor."
::= { benuSensorEntry 8 }
benuSensorId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique ID of the sensor."
::= { benuSensorEntry 9 }
-- The Fan Table
benuFanTable OBJECT-TYPE
SYNTAX SEQUENCE OF BenuFanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Chassis Fan table."
::= { benuFanInfo 1 }
benuFanEntry OBJECT-TYPE
SYNTAX BenuFanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Chassis card table."
INDEX { benuFanCardIndex }
::= { benuFanTable 1 }
BenuFanEntry ::= SEQUENCE {
benuFanCardIndex Unsigned32,
benuFanMaxSpeed Unsigned32,
benuFanCurSpeed Unsigned32,
benuFanStatus Integer32
}
benuFanCardIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"cardIndex of the card in the Chassis cardTable
which contains this Fan."
::= { benuFanEntry 1 }
benuFanMaxSpeed OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum expected speed of each Fan.
This value is applicable to all Fans
in the card.
Units : The value range is from 0 to 100"
::= { benuFanEntry 2 }
benuFanCurSpeed OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current speed of each Fan.
This value is applicable to all Fans
in the card.
Units : The value range is from 0 to 100
and is less than or equal to benuFanMaxSpeed"
::= { benuFanEntry 3 }
benuFanStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" A value of -1 means Not available / Not applicable.
The lower order 7 bits indicates status of 7 Fans.
A bit value of one indicates FAN is non-operational.
A bit value of zero indicates FAN is operational.
Examples :
(a) Value of 1 ( 0000 0001 ) indicates FAN #1 is
non-operational.
(b) Value of 9 ( 0000 1001 ) indicates FAN #1 and FAN #4
are non-operational.
(c) Value of 73( 0100 1001 ) indicates FAN #1,FAN #4 and FAN #7
are non-operational. "
::= { benuFanEntry 4 }
-- The PowerSupply Table
benuPowerSupplyTable OBJECT-TYPE
SYNTAX SEQUENCE OF BenuPowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Benu power supply state information."
::= { benuPowerSupplyInfo 1 }
benuPowerSupplyEntry OBJECT-TYPE
SYNTAX BenuPowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Power supply table."
INDEX { benuPowerSupplyIndex }
::= { benuPowerSupplyTable 1 }
BenuPowerSupplyEntry ::= SEQUENCE {
benuPowerSupplyIndex INTEGER,
benuPowerSupplyName DisplayString,
benuPowerSupplyPresent INTEGER,
benuPowerSupplyType INTEGER,
benuPowerSupplyPowered INTEGER
}
benuPowerSupplyIndex OBJECT-TYPE
SYNTAX INTEGER {
powerA(1),
powerB(2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This object is used to identify the power supply."
::= { benuPowerSupplyEntry 1 }
benuPowerSupplyName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the power supply."
::= { benuPowerSupplyEntry 2 }
benuPowerSupplyPresent OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether or not the power supply is installed in the chassis."
::= { benuPowerSupplyEntry 3 }
benuPowerSupplyType OBJECT-TYPE
SYNTAX INTEGER {
ac(1),
dc(2),
notApplicable(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the type of the power supply."
::= { benuPowerSupplyEntry 4 }
benuPowerSupplyPowered OBJECT-TYPE
SYNTAX INTEGER {
powered(1),
notPowered(2),
notApplicable(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether or not the power supply is actively supplying power.
The value of notApplicable(3) will show if the entry for benuPowerSupplyPresent is no(2)."
::= { benuPowerSupplyEntry 5 }
-- Chassis MIB General Info
benuSysUpTimeSinceLastConfigChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time (in hundredths of a second) since the last
configuration change in the system."
::= { benuChassisGeneralInfo 1 }
-- Chassis MIB traps Definitions
benuChassisPowerFailureInfo OBJECT-TYPE
SYNTAX INTEGER {
powerFailureA(1),
powerFailureB(2),
powerRestoredA(3),
powerRestoredB(4)
}
MAX-ACCESS accessible-for-notify
STATUS obsolete
DESCRIPTION
"Indicates the location of the Power Failure."
::= { benuChassisNotifVariables 1 }
benuChassisPowerFailure NOTIFICATION-TYPE
OBJECTS { benuChassisPowerFailureCardInfo,
benuChassisPowerFailureInfo
}
STATUS obsolete
DESCRIPTION
"A chassisPowerFailureTrap is generated when a Power
Failure is detected in the system"
::= { benuChassisNotifObjects 1 }
benuChassisFanFailureInfo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Indicates the location of the Fan Failure."
::= { benuChassisNotifVariables 2 }
benuChassisFanFailureTrap NOTIFICATION-TYPE
OBJECTS { benuChassisFanFailureInfo }
STATUS current
DESCRIPTION
"A chassisFanFailureTrap is generated when a Fan
Failure is detected in the system"
::= { benuChassisNotifObjects 2 }
benuLinkUpTrap NOTIFICATION-TYPE
OBJECTS {
ifIndex,
ifDescr,
ifType,
ifAdminStatus,
ifOperStatus
}
STATUS current
DESCRIPTION
"A proprietary Link Up Notification for all
interfaces. This notification contains more details
than the standard 'linkUp' notification in RFC 2863."
::= { benuChassisNotifObjects 3 }
benuLinkDownTrap NOTIFICATION-TYPE
OBJECTS {
ifIndex,
ifDescr,
ifType,
ifAdminStatus,
ifOperStatus
}
STATUS current
DESCRIPTION
"A proprietary Link Down Notification for all
interfaces. This notification contains more details
than the standard 'linkDown' notification in RFC 2863."
::= { benuChassisNotifObjects 4 }
benuChassisPowerFailureCardInfo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS accessible-for-notify
STATUS obsolete
DESCRIPTION
"Indicates the Card Index
Card Index starts from #1. "
::= { benuChassisNotifVariables 3 }
benuSensorCritical NOTIFICATION-TYPE
OBJECTS {
benuSensorName,
benuSensorType,
benuSensorValue,
benuSensorId
}
STATUS current
DESCRIPTION
"This notification signifies the transition
of the sensor state from normal to critical."
::= { benuChassisNotifObjects 5 }
benuSensorNormal NOTIFICATION-TYPE
OBJECTS {
benuSensorName,
benuSensorType,
benuSensorValue,
benuSensorId
}
STATUS current
DESCRIPTION
"This notification signifies the transition
of the sensor state from critical to normal."
::= { benuChassisNotifObjects 6 }
benuChassisPowerInfo OBJECT-TYPE
SYNTAX INTEGER {
powerSupplyA(1),
powerSupplyB(2)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Indicates the location of the Power Failure or recovery."
::= { benuChassisNotifVariables 4 }
benuChassisPowerFault NOTIFICATION-TYPE
OBJECTS { benuChassisPowerInfo
}
STATUS current
DESCRIPTION
"A chassisPowerFaultTrap is generated when a Power
Failure is detected in the system"
::= { benuChassisNotifObjects 7 }
benuChassisPowerRecovery NOTIFICATION-TYPE
OBJECTS { benuChassisPowerInfo
}
STATUS current
DESCRIPTION
"A chassisPowerRecoveryTrap is generated when a failed
Power supply recovery is detected in the system"
::= { benuChassisNotifObjects 8 }
benuChassisPowerPresent NOTIFICATION-TYPE
OBJECTS { benuChassisPowerInfo
}
STATUS current
DESCRIPTION
"A chassisPowerPresentTrap is generated when a
redundant Power supply is inserted in the system"
::= { benuChassisNotifObjects 9 }
benuChassisPowerAbsent NOTIFICATION-TYPE
OBJECTS { benuChassisPowerInfo
}
STATUS current
DESCRIPTION
"A chassisPowerAbsentTrap is generated when a
redundant Power supply is removed from the system"
::= { benuChassisNotifObjects 10 }
END