2408 lines
81 KiB
Plaintext
2408 lines
81 KiB
Plaintext
-- *********************************************************************************************
|
|
-- *
|
|
-- * Description: Implements definitions for the Optical Amplifiers
|
|
-- *
|
|
-- * Note: This specification is written for the new high power optical anplifiers,
|
|
-- * but is intended to represent all new optical amplifiers in the future !!!
|
|
-- * That is why a superset of all optical amplifier features is specified here.
|
|
-- *
|
|
-- * Copyright 2007 by BKtel communications GmbH
|
|
-- *
|
|
-- * V.0.1 23.03.2007 M. Heldmann first draft
|
|
-- * V.0.2 25.04.2007 M. Heldmann some items added to oaDisplayTable
|
|
-- * V.0.3 01.06.2007 M. Heldmann changed oaStatesTecHeatHigh to oaStatesTecCurrentLow
|
|
-- * and oaStatesTecCoolHigh to oaStatesTecCurrentHigh
|
|
-- * V.0.4 12.09.2007 M. Heldmann adjusted 'LaserFeatures' type strings
|
|
-- * (max. stringsize less than 64 characters)
|
|
-- * V.0.5 04.04.2008 M. Heldmann oaReturnLossLoLo..oaReturnLossHiHi made read-write
|
|
-- * (same behaviour as in web-interface)
|
|
-- * V.0.6 22.03.2013 M. Heldmann added raman-type amplifier extensions
|
|
-- * oaStatesRamanBackReflectionRatio, oaStatesRamanOscSignalMissing
|
|
-- * and oaDisplayAmplifierIsRamanType
|
|
-- * V.0.7 11.07.2013 M. Heldmann adjusted syntax of "CommonEntry" to remove MIB compiler warnings
|
|
-- * V.0.8 06.05.2014 M. Heldmann marked all internal voltage parameters as 'optional'
|
|
-- * V.0.9 05.09.2014 M. Heldmann changed CommonModuleWidth and ConfigNESlotWrite STATUS to optional
|
|
-- *********************************************************************************************
|
|
|
|
|
|
BKTEL-HFC862-OA-V01-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
modules, DisplayString, TruthValue, PerceivedSeverityValue, NESlotValue, ModuleWidthValue
|
|
FROM BKTEL-HFC862-BASE-MIB
|
|
;
|
|
|
|
oa OBJECT IDENTIFIER ::= { modules 116 }
|
|
oaCommon OBJECT IDENTIFIER ::= { oa 1 }
|
|
oaStates OBJECT IDENTIFIER ::= { oa 2 }
|
|
oaConfiguration OBJECT IDENTIFIER ::= { oa 3 }
|
|
oaControl OBJECT IDENTIFIER ::= { oa 4 }
|
|
oaMeasuringValues OBJECT IDENTIFIER ::= { oa 5 }
|
|
oaDisplay OBJECT IDENTIFIER ::= { oa 6 }
|
|
|
|
|
|
--
|
|
-- Type definitions
|
|
--
|
|
|
|
|
|
RegulationMode ::= INTEGER
|
|
{
|
|
regModeConstantOutputPower(1),
|
|
regModeConstantGain(2)
|
|
}
|
|
|
|
SbsEvaluationMode ::= INTEGER
|
|
{
|
|
evalModeDefault(1),
|
|
evalModeFullScan(2)
|
|
}
|
|
|
|
SbsEvaluationState ::= INTEGER
|
|
{
|
|
evaluationNotSupported(1),
|
|
evaluationDone(2),
|
|
evaluationInProgress(3),
|
|
evaluationFailed(4)
|
|
}
|
|
|
|
ExtIOmode ::= INTEGER
|
|
{
|
|
modeActiveLowOutput(1),
|
|
modeActiveHighOutput(2),
|
|
modeRedundantMasterIrreversible(3),
|
|
modeRedundantMasterFallback(4),
|
|
modeRedundantSlave(5)
|
|
}
|
|
|
|
ExtIOmask ::= INTEGER
|
|
{
|
|
maskAlarmsOnly(1),
|
|
maskAlarmsAndWarnings(2),
|
|
maskSpecial(3) -- This item is NOT writable !!
|
|
}
|
|
|
|
LaserFeatures ::= INTEGER
|
|
{
|
|
lasNonExistent(0),
|
|
lasCurrent(1),
|
|
lasCurrentLasTec(3),
|
|
lasCurrentLasTemperature(5),
|
|
lasCurrentLasTecLasTemperature(7),
|
|
lasCurrentLasVoltage(9),
|
|
lasCurrentLasTecLasVoltage(11),
|
|
lasCurrentLasTemperatureLasVoltage(13),
|
|
lasCurrentLasTecLasTemperatureLasVoltage(15),
|
|
lasCurrentLasPumpPower(17),
|
|
lasCurrentLasTecLasPumpPower(19),
|
|
lasCurrentLasTemperatureLasPumpPower(21),
|
|
lasCurrentLasTecLasTemperatureLasPumpPower(23),
|
|
lasCurrentLasVoltageLasPumpPower(25),
|
|
lasCurrentLasTecLasVoltageLasPumpPower(27),
|
|
lasCurrentLasTemperatureLasVoltageLasPumpPower(29),
|
|
lasCurrentLasTecLasTemperatureLasVoltageLasPumpPower(31)
|
|
}
|
|
|
|
NESlotWriteValue ::= INTEGER (-1..99)
|
|
|
|
|
|
-- MibCompiler defs --
|
|
-- $idx$: InternalVoltage
|
|
-- $idx$: Laser
|
|
-- MibCompiler defs --
|
|
|
|
--*****************************************************************************************
|
|
-- OA ( Optical Amplifier)
|
|
|
|
--*****************************************************************************************
|
|
-- oaCommon group
|
|
|
|
oaCommonNumberOfModules OBJECT-TYPE
|
|
SYNTAX INTEGER(0..50)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Number of modules in table."
|
|
::= { oaCommon 1 }
|
|
|
|
oaCommonTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OaCommonEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "The table contains all modules of the OA-type in the NE"
|
|
::= { oaCommon 2 }
|
|
|
|
-- table of states entry(ro/rw)
|
|
|
|
oaCommonEntry OBJECT-TYPE
|
|
SYNTAX OaCommonEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Common-Values for a module."
|
|
INDEX { oaNESlot }
|
|
::= { oaCommonTable 1 }
|
|
|
|
-- the structure of the entry
|
|
|
|
OaCommonEntry ::= SEQUENCE
|
|
{
|
|
oaNESlot NESlotValue,
|
|
oaCommonType DisplayString,
|
|
oaCommonDescr DisplayString,
|
|
oaCommonFirmwareId DisplayString,
|
|
oaCommonModuleWidth ModuleWidthValue
|
|
}
|
|
|
|
oaNESlot OBJECT-TYPE
|
|
SYNTAX NESlotValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The slot number of the chassis for which this
|
|
entry contains management information."
|
|
::= { oaCommonEntry 1 }
|
|
|
|
oaCommonType OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of physical module. modSlotEmpty indicates
|
|
an empty slot. A Value of modSlotUnknown indicates
|
|
that the type of module is unknown."
|
|
::= { oaCommonEntry 2 }
|
|
|
|
oaCommonDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A textual description of the module.
|
|
If not available, this Value should be
|
|
set to a zero length string."
|
|
::= { oaCommonEntry 3 }
|
|
|
|
oaCommonFirmwareId OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The firmware Id of the module."
|
|
::= { oaCommonEntry 4 }
|
|
|
|
oaCommonModuleWidth OBJECT-TYPE
|
|
SYNTAX ModuleWidthValue
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The width of the module in multiples of slots (1, 2, ...)"
|
|
::= { oaCommonEntry 5 }
|
|
|
|
--*****************************************************************************************
|
|
-- oaMeasuringValues group
|
|
--
|
|
-- !!! NOTE !!!
|
|
--
|
|
-- Measuring values in this table that are not supported by the device
|
|
-- return zero for the value and its limits.
|
|
|
|
-- table of measuring Values
|
|
|
|
oaMeasuringValuesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OaMeasuringValuesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaMeasuringValues 1 }
|
|
|
|
-- table of measuring Values entry
|
|
|
|
oaMeasuringValuesEntry OBJECT-TYPE
|
|
SYNTAX OaMeasuringValuesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Common-Values for a module."
|
|
INDEX { oaNESlot }
|
|
::= { oaMeasuringValuesTable 1 }
|
|
|
|
-- the structure of the entry
|
|
|
|
OaMeasuringValuesEntry ::= SEQUENCE
|
|
{
|
|
oaTemperatureLoLo INTEGER,
|
|
oaTemperatureLo INTEGER,
|
|
oaTemperatureValue INTEGER,
|
|
oaTemperatureHi INTEGER,
|
|
oaTemperatureHiHi INTEGER,
|
|
|
|
oaInputPowerLoLo INTEGER,
|
|
oaInputPowerLo INTEGER,
|
|
oaInputPowerValue INTEGER,
|
|
oaInputPowerHi INTEGER,
|
|
oaInputPowerHiHi INTEGER,
|
|
|
|
oaOutputPwrOrGainLoLo INTEGER,
|
|
oaOutputPwrOrGainLo INTEGER,
|
|
oaOutputPwrOrGainValue INTEGER,
|
|
oaOutputPwrOrGainHi INTEGER,
|
|
oaOutputPwrOrGainHiHi INTEGER,
|
|
|
|
oaReturnLossLoLo INTEGER,
|
|
oaReturnLossLo INTEGER,
|
|
oaReturnLossValue INTEGER,
|
|
oaReturnLossHi INTEGER,
|
|
oaReturnLossHiHi INTEGER,
|
|
|
|
oaInputVoltageLoLo INTEGER,
|
|
oaInputVoltageLo INTEGER,
|
|
oaInputVoltageValue INTEGER,
|
|
oaInputVoltageHi INTEGER,
|
|
oaInputVoltageHiHi INTEGER,
|
|
|
|
oaInternalVoltage1LoLo INTEGER,
|
|
oaInternalVoltage1Lo INTEGER,
|
|
oaInternalVoltage1Value INTEGER,
|
|
oaInternalVoltage1Hi INTEGER,
|
|
oaInternalVoltage1HiHi INTEGER,
|
|
|
|
oaInternalVoltage2LoLo INTEGER,
|
|
oaInternalVoltage2Lo INTEGER,
|
|
oaInternalVoltage2Value INTEGER,
|
|
oaInternalVoltage2Hi INTEGER,
|
|
oaInternalVoltage2HiHi INTEGER,
|
|
|
|
oaInternalVoltage3LoLo INTEGER,
|
|
oaInternalVoltage3Lo INTEGER,
|
|
oaInternalVoltage3Value INTEGER,
|
|
oaInternalVoltage3Hi INTEGER,
|
|
oaInternalVoltage3HiHi INTEGER,
|
|
|
|
-- ***
|
|
|
|
oaLaser1CurrentRelLoLo INTEGER,
|
|
oaLaser1CurrentRelLo INTEGER,
|
|
oaLaser1CurrentRelValue INTEGER,
|
|
oaLaser1CurrentRelHi INTEGER,
|
|
oaLaser1CurrentRelHiHi INTEGER,
|
|
|
|
oaLaser1TecRelLoLo INTEGER,
|
|
oaLaser1TecRelLo INTEGER,
|
|
oaLaser1TecRelValue INTEGER,
|
|
oaLaser1TecRelHi INTEGER,
|
|
oaLaser1TecRelHiHi INTEGER,
|
|
|
|
oaLaser1TemperatureLoLo INTEGER,
|
|
oaLaser1TemperatureLo INTEGER,
|
|
oaLaser1TemperatureValue INTEGER,
|
|
oaLaser1TemperatureHi INTEGER,
|
|
oaLaser1TemperatureHiHi INTEGER,
|
|
|
|
oaLaser1VoltageLoLo INTEGER,
|
|
oaLaser1VoltageLo INTEGER,
|
|
oaLaser1VoltageValue INTEGER,
|
|
oaLaser1VoltageHi INTEGER,
|
|
oaLaser1VoltageHiHi INTEGER,
|
|
|
|
-- ***
|
|
|
|
oaLaser2CurrentRelLoLo INTEGER,
|
|
oaLaser2CurrentRelLo INTEGER,
|
|
oaLaser2CurrentRelValue INTEGER,
|
|
oaLaser2CurrentRelHi INTEGER,
|
|
oaLaser2CurrentRelHiHi INTEGER,
|
|
|
|
oaLaser2TecRelLoLo INTEGER,
|
|
oaLaser2TecRelLo INTEGER,
|
|
oaLaser2TecRelValue INTEGER,
|
|
oaLaser2TecRelHi INTEGER,
|
|
oaLaser2TecRelHiHi INTEGER,
|
|
|
|
oaLaser2TemperatureLoLo INTEGER,
|
|
oaLaser2TemperatureLo INTEGER,
|
|
oaLaser2TemperatureValue INTEGER,
|
|
oaLaser2TemperatureHi INTEGER,
|
|
oaLaser2TemperatureHiHi INTEGER,
|
|
|
|
oaLaser2VoltageLoLo INTEGER,
|
|
oaLaser2VoltageLo INTEGER,
|
|
oaLaser2VoltageValue INTEGER,
|
|
oaLaser2VoltageHi INTEGER,
|
|
oaLaser2VoltageHiHi INTEGER,
|
|
|
|
-- ***
|
|
|
|
oaLaser3CurrentRelLoLo INTEGER,
|
|
oaLaser3CurrentRelLo INTEGER,
|
|
oaLaser3CurrentRelValue INTEGER,
|
|
oaLaser3CurrentRelHi INTEGER,
|
|
oaLaser3CurrentRelHiHi INTEGER,
|
|
|
|
oaLaser3TecRelLoLo INTEGER,
|
|
oaLaser3TecRelLo INTEGER,
|
|
oaLaser3TecRelValue INTEGER,
|
|
oaLaser3TecRelHi INTEGER,
|
|
oaLaser3TecRelHiHi INTEGER,
|
|
|
|
oaLaser3TemperatureLoLo INTEGER,
|
|
oaLaser3TemperatureLo INTEGER,
|
|
oaLaser3TemperatureValue INTEGER,
|
|
oaLaser3TemperatureHi INTEGER,
|
|
oaLaser3TemperatureHiHi INTEGER,
|
|
|
|
oaLaser3VoltageLoLo INTEGER,
|
|
oaLaser3VoltageLo INTEGER,
|
|
oaLaser3VoltageValue INTEGER,
|
|
oaLaser3VoltageHi INTEGER,
|
|
oaLaser3VoltageHiHi INTEGER,
|
|
|
|
-- ***
|
|
|
|
oaLaser4CurrentRelLoLo INTEGER,
|
|
oaLaser4CurrentRelLo INTEGER,
|
|
oaLaser4CurrentRelValue INTEGER,
|
|
oaLaser4CurrentRelHi INTEGER,
|
|
oaLaser4CurrentRelHiHi INTEGER,
|
|
|
|
oaLaser4TecRelLoLo INTEGER,
|
|
oaLaser4TecRelLo INTEGER,
|
|
oaLaser4TecRelValue INTEGER,
|
|
oaLaser4TecRelHi INTEGER,
|
|
oaLaser4TecRelHiHi INTEGER,
|
|
|
|
oaLaser4TemperatureLoLo INTEGER,
|
|
oaLaser4TemperatureLo INTEGER,
|
|
oaLaser4TemperatureValue INTEGER,
|
|
oaLaser4TemperatureHi INTEGER,
|
|
oaLaser4TemperatureHiHi INTEGER,
|
|
|
|
oaLaser4VoltageLoLo INTEGER,
|
|
oaLaser4VoltageLo INTEGER,
|
|
oaLaser4VoltageValue INTEGER,
|
|
oaLaser4VoltageHi INTEGER,
|
|
oaLaser4VoltageHiHi INTEGER,
|
|
|
|
-- ***
|
|
|
|
oaLaser5CurrentRelLoLo INTEGER,
|
|
oaLaser5CurrentRelLo INTEGER,
|
|
oaLaser5CurrentRelValue INTEGER,
|
|
oaLaser5CurrentRelHi INTEGER,
|
|
oaLaser5CurrentRelHiHi INTEGER,
|
|
|
|
oaLaser5TecRelLoLo INTEGER,
|
|
oaLaser5TecRelLo INTEGER,
|
|
oaLaser5TecRelValue INTEGER,
|
|
oaLaser5TecRelHi INTEGER,
|
|
oaLaser5TecRelHiHi INTEGER,
|
|
|
|
oaLaser5TemperatureLoLo INTEGER,
|
|
oaLaser5TemperatureLo INTEGER,
|
|
oaLaser5TemperatureValue INTEGER,
|
|
oaLaser5TemperatureHi INTEGER,
|
|
oaLaser5TemperatureHiHi INTEGER,
|
|
|
|
oaLaser5VoltageLoLo INTEGER,
|
|
oaLaser5VoltageLo INTEGER,
|
|
oaLaser5VoltageValue INTEGER,
|
|
oaLaser5VoltageHi INTEGER,
|
|
oaLaser5VoltageHiHi INTEGER,
|
|
|
|
-- ***
|
|
|
|
oaLaser6CurrentRelLoLo INTEGER,
|
|
oaLaser6CurrentRelLo INTEGER,
|
|
oaLaser6CurrentRelValue INTEGER,
|
|
oaLaser6CurrentRelHi INTEGER,
|
|
oaLaser6CurrentRelHiHi INTEGER,
|
|
|
|
oaLaser6TecRelLoLo INTEGER,
|
|
oaLaser6TecRelLo INTEGER,
|
|
oaLaser6TecRelValue INTEGER,
|
|
oaLaser6TecRelHi INTEGER,
|
|
oaLaser6TecRelHiHi INTEGER,
|
|
|
|
oaLaser6TemperatureLoLo INTEGER,
|
|
oaLaser6TemperatureLo INTEGER,
|
|
oaLaser6TemperatureValue INTEGER,
|
|
oaLaser6TemperatureHi INTEGER,
|
|
oaLaser6TemperatureHiHi INTEGER,
|
|
|
|
oaLaser6VoltageLoLo INTEGER,
|
|
oaLaser6VoltageLo INTEGER,
|
|
oaLaser6VoltageValue INTEGER,
|
|
oaLaser6VoltageHi INTEGER,
|
|
oaLaser6VoltageHiHi INTEGER
|
|
}
|
|
|
|
-- *****
|
|
oaTemperatureLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The module temperature low alarm threshold in steps of 0.1 celsius degrees."
|
|
::= { oaMeasuringValuesEntry 1 }
|
|
|
|
oaTemperatureLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The module temperature low warning threshold in steps of 0.1 celsius degrees."
|
|
::= { oaMeasuringValuesEntry 2 }
|
|
|
|
oaTemperatureValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The module temperature in steps of 0.1 celsius degrees."
|
|
::= { oaMeasuringValuesEntry 3 }
|
|
|
|
oaTemperatureHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The module temperature high warning threshold in steps of 0.1 celsius degrees."
|
|
::= { oaMeasuringValuesEntry 4 }
|
|
|
|
oaTemperatureHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The module temperature high alarm threshold in steps of 0.1 celsius degrees."
|
|
::= { oaMeasuringValuesEntry 5 }
|
|
|
|
-- *****
|
|
oaInputPowerLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Input power low alarm threshold in steps of 0.1dBm."
|
|
::= { oaMeasuringValuesEntry 6 }
|
|
|
|
oaInputPowerLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Input power low warning threshold in steps of 0.1dBm."
|
|
::= { oaMeasuringValuesEntry 7 }
|
|
|
|
oaInputPowerValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input power in steps of 0.1dBm."
|
|
::= { oaMeasuringValuesEntry 8 }
|
|
|
|
oaInputPowerHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Input power high warning threshold in steps of 0.1dBm."
|
|
::= { oaMeasuringValuesEntry 9 }
|
|
|
|
oaInputPowerHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Input power high alarm threshold in steps of 0.1dBm."
|
|
::= { oaMeasuringValuesEntry 10 }
|
|
|
|
-- *****
|
|
oaOutputPwrOrGainLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Output power (or gain) low alarm threshold in steps of 0.1dB(m).
|
|
See oaConfigRegulationMode variable too"
|
|
::= { oaMeasuringValuesEntry 11 }
|
|
|
|
oaOutputPwrOrGainLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Output power (or gain) low warning threshold in steps of 0.1dB(m).
|
|
See oaConfigRegulationMode variable too"
|
|
::= { oaMeasuringValuesEntry 12 }
|
|
|
|
oaOutputPwrOrGainValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Output power (or gain) in steps of 0.1dB(m).
|
|
See oaConfigRegulationMode variable too"
|
|
::= { oaMeasuringValuesEntry 13 }
|
|
|
|
oaOutputPwrOrGainHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Output power (or gain) high warning threshold in steps of 0.1dB(m).
|
|
See oaConfigRegulationMode variable too"
|
|
::= { oaMeasuringValuesEntry 14 }
|
|
|
|
oaOutputPwrOrGainHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Output power (or gain) high alarm threshold in steps of 0.1dB(m).
|
|
See oaConfigRegulationMode variable too"
|
|
::= { oaMeasuringValuesEntry 15 }
|
|
|
|
-- *****
|
|
oaReturnLossLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "ReturnLoss low alarm threshold in steps of 0.1 dB."
|
|
::= { oaMeasuringValuesEntry 16 }
|
|
|
|
oaReturnLossLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "ReturnLoss low warning threshold in steps of 0.1 dB."
|
|
::= { oaMeasuringValuesEntry 17 }
|
|
|
|
oaReturnLossValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "ReturnLoss in steps of 0.1 dB."
|
|
::= { oaMeasuringValuesEntry 18 }
|
|
|
|
oaReturnLossHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "ReturnLoss high warning threshold in steps of 0.1 dB."
|
|
::= { oaMeasuringValuesEntry 19 }
|
|
|
|
oaReturnLossHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "ReturnLoss high alarm threshold in steps of 0.1 dB."
|
|
::= { oaMeasuringValuesEntry 20 }
|
|
|
|
-- *****
|
|
oaInputVoltageLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The input supply voltage low alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 21 }
|
|
|
|
oaInputVoltageLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The input supply voltage low warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 22 }
|
|
|
|
oaInputVoltageValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The input supply voltage in steps of 0.1 Volts.
|
|
Input supply voltage nominal value, see 'oaDisplayInputVoltageNominal'"
|
|
::= { oaMeasuringValuesEntry 23 }
|
|
|
|
oaInputVoltageHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The input supply voltage high warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 24 }
|
|
|
|
oaInputVoltageHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The input supply voltage high alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 25 }
|
|
|
|
-- #####+20 Space reserved for 4 additional measuring values with limits
|
|
|
|
-- ########################### Internal Voltages Section ##################################
|
|
|
|
-- *****
|
|
oaInternalVoltage1LoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The internal voltage low alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 46 }
|
|
|
|
oaInternalVoltage1Lo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The internal voltage low warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 47 }
|
|
|
|
oaInternalVoltage1Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The internal voltage in steps of 0.1 Volts.
|
|
Internal voltage nominal value, see 'oaDisplayInternalVoltage1Nominal'"
|
|
::= { oaMeasuringValuesEntry 48 }
|
|
|
|
oaInternalVoltage1Hi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The internal voltage high warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 49 }
|
|
|
|
oaInternalVoltage1HiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The internal voltage high alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 50 }
|
|
|
|
-- *****
|
|
oaInternalVoltage2LoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The internal voltage low alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 51 }
|
|
|
|
oaInternalVoltage2Lo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The internal voltage low warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 52 }
|
|
|
|
oaInternalVoltage2Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The internal voltage in steps of 0.1 Volts.
|
|
Internal voltage nominal value, see 'oaDisplayInternalVoltage2Nominal'"
|
|
::= { oaMeasuringValuesEntry 53 }
|
|
|
|
oaInternalVoltage2Hi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The internal voltage high warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 54 }
|
|
|
|
oaInternalVoltage2HiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The internal voltage high alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 55 }
|
|
|
|
-- *****
|
|
oaInternalVoltage3LoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The internal voltage low alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 56 }
|
|
|
|
oaInternalVoltage3Lo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The internal voltage low warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 57 }
|
|
|
|
oaInternalVoltage3Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The internal voltage in steps of 0.1 Volts.
|
|
Internal voltage nominal value, see 'oaDisplayInternalVoltage3Nominal'"
|
|
::= { oaMeasuringValuesEntry 58 }
|
|
|
|
oaInternalVoltage3Hi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The internal voltage high warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 59 }
|
|
|
|
oaInternalVoltage3HiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The internal voltage high alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 60 }
|
|
|
|
-- #####+25 Space reserved for 5 additional internal voltage measuring values with limits
|
|
|
|
-- ################################### Lasers Section ##################################
|
|
|
|
-- ***********************************
|
|
oaLaser1CurrentRelLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current low alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 86 }
|
|
|
|
oaLaser1CurrentRelLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current low warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 87 }
|
|
|
|
oaLaser1CurrentRelValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The laser no.1 current relative to the current at begin of life in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 88 }
|
|
|
|
oaLaser1CurrentRelHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current high warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 89 }
|
|
|
|
oaLaser1CurrentRelHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current high alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 90 }
|
|
|
|
-- *****
|
|
oaLaser1TecRelLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 91 }
|
|
|
|
oaLaser1TecRelLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 92 }
|
|
|
|
oaLaser1TecRelValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 93 }
|
|
|
|
oaLaser1TecRelHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 94 }
|
|
|
|
oaLaser1TecRelHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 95 }
|
|
|
|
-- *****
|
|
oaLaser1TemperatureLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 96 }
|
|
|
|
oaLaser1TemperatureLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 97 }
|
|
|
|
oaLaser1TemperatureValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 98 }
|
|
|
|
oaLaser1TemperatureHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 99 }
|
|
|
|
oaLaser1TemperatureHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 100 }
|
|
|
|
-- *****
|
|
oaLaser1VoltageLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 101 }
|
|
|
|
oaLaser1VoltageLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 102 }
|
|
|
|
oaLaser1VoltageValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 103 }
|
|
|
|
oaLaser1VoltageHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 104 }
|
|
|
|
oaLaser1VoltageHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 105 }
|
|
|
|
-- #####+5 Space reserved for 1 additional laser measuring value with limits
|
|
|
|
-- ***********************************
|
|
oaLaser2CurrentRelLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current low alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 111 }
|
|
|
|
oaLaser2CurrentRelLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current low warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 112 }
|
|
|
|
oaLaser2CurrentRelValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The laser no.1 current relative to the current at begin of life in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 113 }
|
|
|
|
oaLaser2CurrentRelHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current high warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 114 }
|
|
|
|
oaLaser2CurrentRelHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current high alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 115 }
|
|
|
|
-- *****
|
|
oaLaser2TecRelLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 116 }
|
|
|
|
oaLaser2TecRelLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 117 }
|
|
|
|
oaLaser2TecRelValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 118 }
|
|
|
|
oaLaser2TecRelHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 119 }
|
|
|
|
oaLaser2TecRelHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 120 }
|
|
|
|
-- *****
|
|
oaLaser2TemperatureLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 121 }
|
|
|
|
oaLaser2TemperatureLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 122 }
|
|
|
|
oaLaser2TemperatureValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 123 }
|
|
|
|
oaLaser2TemperatureHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 124 }
|
|
|
|
oaLaser2TemperatureHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 125 }
|
|
|
|
-- *****
|
|
oaLaser2VoltageLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 126 }
|
|
|
|
oaLaser2VoltageLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 127 }
|
|
|
|
oaLaser2VoltageValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 128 }
|
|
|
|
oaLaser2VoltageHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 129 }
|
|
|
|
oaLaser2VoltageHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 130 }
|
|
|
|
-- #####+5 Space reserved for 1 additional laser measuring value with limits
|
|
|
|
-- ***********************************
|
|
oaLaser3CurrentRelLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current low alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 136 }
|
|
|
|
oaLaser3CurrentRelLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current low warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 137 }
|
|
|
|
oaLaser3CurrentRelValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The laser no.1 current relative to the current at begin of life in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 138 }
|
|
|
|
oaLaser3CurrentRelHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current high warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 139 }
|
|
|
|
oaLaser3CurrentRelHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current high alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 140 }
|
|
|
|
-- *****
|
|
oaLaser3TecRelLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 141 }
|
|
|
|
oaLaser3TecRelLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 142 }
|
|
|
|
oaLaser3TecRelValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 143 }
|
|
|
|
oaLaser3TecRelHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 144 }
|
|
|
|
oaLaser3TecRelHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 145 }
|
|
|
|
-- *****
|
|
oaLaser3TemperatureLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 146 }
|
|
|
|
oaLaser3TemperatureLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 147 }
|
|
|
|
oaLaser3TemperatureValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 148 }
|
|
|
|
oaLaser3TemperatureHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 149 }
|
|
|
|
oaLaser3TemperatureHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 150 }
|
|
|
|
-- *****
|
|
oaLaser3VoltageLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 151 }
|
|
|
|
oaLaser3VoltageLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 152 }
|
|
|
|
oaLaser3VoltageValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 153 }
|
|
|
|
oaLaser3VoltageHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 154 }
|
|
|
|
oaLaser3VoltageHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 155 }
|
|
|
|
-- #####+5 Space reserved for 1 additional laser measuring value with limits
|
|
|
|
-- ***********************************
|
|
oaLaser4CurrentRelLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current low alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 161 }
|
|
|
|
oaLaser4CurrentRelLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current low warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 162 }
|
|
|
|
oaLaser4CurrentRelValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The laser no.1 current relative to the current at begin of life in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 163 }
|
|
|
|
oaLaser4CurrentRelHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current high warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 164 }
|
|
|
|
oaLaser4CurrentRelHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current high alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 165 }
|
|
|
|
-- *****
|
|
oaLaser4TecRelLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 166 }
|
|
|
|
oaLaser4TecRelLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 167 }
|
|
|
|
oaLaser4TecRelValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 168 }
|
|
|
|
oaLaser4TecRelHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 169 }
|
|
|
|
oaLaser4TecRelHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 170 }
|
|
|
|
-- *****
|
|
oaLaser4TemperatureLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 171 }
|
|
|
|
oaLaser4TemperatureLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 172 }
|
|
|
|
oaLaser4TemperatureValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 173 }
|
|
|
|
oaLaser4TemperatureHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 174 }
|
|
|
|
oaLaser4TemperatureHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 175 }
|
|
|
|
-- *****
|
|
oaLaser4VoltageLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 176 }
|
|
|
|
oaLaser4VoltageLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 177 }
|
|
|
|
oaLaser4VoltageValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 178 }
|
|
|
|
oaLaser4VoltageHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 179 }
|
|
|
|
oaLaser4VoltageHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 180 }
|
|
|
|
-- #####+5 Space reserved for 1 additional laser measuring value with limits
|
|
|
|
-- ***********************************
|
|
oaLaser5CurrentRelLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current low alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 186 }
|
|
|
|
oaLaser5CurrentRelLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current low warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 187 }
|
|
|
|
oaLaser5CurrentRelValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The laser no.1 current relative to the current at begin of life in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 188 }
|
|
|
|
oaLaser5CurrentRelHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current high warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 189 }
|
|
|
|
oaLaser5CurrentRelHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current high alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 190 }
|
|
|
|
-- *****
|
|
oaLaser5TecRelLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 191 }
|
|
|
|
oaLaser5TecRelLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 192 }
|
|
|
|
oaLaser5TecRelValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 193 }
|
|
|
|
oaLaser5TecRelHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 194 }
|
|
|
|
oaLaser5TecRelHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 195 }
|
|
|
|
-- *****
|
|
oaLaser5TemperatureLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 196 }
|
|
|
|
oaLaser5TemperatureLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 197 }
|
|
|
|
oaLaser5TemperatureValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 198 }
|
|
|
|
oaLaser5TemperatureHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 199 }
|
|
|
|
oaLaser5TemperatureHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 200 }
|
|
|
|
-- *****
|
|
oaLaser5VoltageLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 201 }
|
|
|
|
oaLaser5VoltageLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 202 }
|
|
|
|
oaLaser5VoltageValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 203 }
|
|
|
|
oaLaser5VoltageHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 204 }
|
|
|
|
oaLaser5VoltageHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 205 }
|
|
|
|
-- #####+5 Space reserved for 1 additional laser measuring value with limits
|
|
|
|
-- ***********************************
|
|
oaLaser6CurrentRelLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current low alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 211 }
|
|
|
|
oaLaser6CurrentRelLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current low warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 212 }
|
|
|
|
oaLaser6CurrentRelValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The laser no.1 current relative to the current at begin of life in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 213 }
|
|
|
|
oaLaser6CurrentRelHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current high warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 214 }
|
|
|
|
oaLaser6CurrentRelHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Relative laser no.1 current high alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 215 }
|
|
|
|
-- *****
|
|
oaLaser6TecRelLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 216 }
|
|
|
|
oaLaser6TecRelLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 217 }
|
|
|
|
oaLaser6TecRelValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 218 }
|
|
|
|
oaLaser6TecRelHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 219 }
|
|
|
|
oaLaser6TecRelHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Thermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%."
|
|
::= { oaMeasuringValuesEntry 220 }
|
|
|
|
-- *****
|
|
oaLaser6TemperatureLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 221 }
|
|
|
|
oaLaser6TemperatureLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 222 }
|
|
|
|
oaLaser6TemperatureValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 223 }
|
|
|
|
oaLaser6TemperatureHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 224 }
|
|
|
|
oaLaser6TemperatureHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Temperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees."
|
|
::= { oaMeasuringValuesEntry 225 }
|
|
|
|
-- *****
|
|
oaLaser6VoltageLoLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 226 }
|
|
|
|
oaLaser6VoltageLo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 227 }
|
|
|
|
oaLaser6VoltageValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 228 }
|
|
|
|
oaLaser6VoltageHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 229 }
|
|
|
|
oaLaser6VoltageHiHi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION "The supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts."
|
|
::= { oaMeasuringValuesEntry 230 }
|
|
|
|
-- #####+5 Space reserved for 1 additional laser measuring value with limits
|
|
|
|
|
|
--*****************************************************************************************
|
|
-- oaStates group
|
|
|
|
oaStatesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OaStatesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaStates 1 }
|
|
|
|
-- table of states entry(ro/rw)
|
|
|
|
oaStatesEntry OBJECT-TYPE
|
|
SYNTAX OaStatesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Alarms for a module."
|
|
INDEX { oaNESlot }
|
|
::= { oaStatesTable 1 }
|
|
|
|
-- the structure of the entry
|
|
|
|
OaStatesEntry ::= SEQUENCE
|
|
{
|
|
oaStatesBootloader PerceivedSeverityValue,
|
|
oaStatesCommLoss PerceivedSeverityValue,
|
|
oaStatesInitializing PerceivedSeverityValue,
|
|
oaStatesLaserShutdown PerceivedSeverityValue,
|
|
oaStatesTemperatureLow PerceivedSeverityValue,
|
|
oaStatesTemperatureHigh PerceivedSeverityValue,
|
|
oaStatesSystem PerceivedSeverityValue,
|
|
oaStatesInputPwrLow PerceivedSeverityValue,
|
|
oaStatesInputPwrHigh PerceivedSeverityValue,
|
|
oaStatesOutputPwrOrGainLow PerceivedSeverityValue,
|
|
oaStatesOutputPwrOrGainHigh PerceivedSeverityValue,
|
|
oaStatesReturnLossLow PerceivedSeverityValue,
|
|
oaStatesReturnLossHigh PerceivedSeverityValue,
|
|
oaStatesRedundancySwitch PerceivedSeverityValue,
|
|
oaStatesInputVoltageLow PerceivedSeverityValue,
|
|
oaStatesInputVoltageHigh PerceivedSeverityValue,
|
|
-- ** Only for 19 inch devices with supply and fan units
|
|
oaStatesPowerSupplyLeft PerceivedSeverityValue,
|
|
oaStatesPowerSupplyRight PerceivedSeverityValue,
|
|
oaStatesFanLeft PerceivedSeverityValue,
|
|
oaStatesFanRight PerceivedSeverityValue,
|
|
-- ** Shared alarms for all internal voltages
|
|
oaStatesInternalVoltageLow PerceivedSeverityValue,
|
|
oaStatesInternalVoltageHigh PerceivedSeverityValue,
|
|
-- ** Shared alarms for all laser parameters
|
|
oaStatesLaserCurrentLow PerceivedSeverityValue,
|
|
oaStatesLaserCurrentHigh PerceivedSeverityValue,
|
|
oaStatesTecCurrentLow PerceivedSeverityValue,
|
|
oaStatesTecCurrentHigh PerceivedSeverityValue,
|
|
oaStatesLaserTempLow PerceivedSeverityValue,
|
|
oaStatesLaserTempHigh PerceivedSeverityValue,
|
|
oaStatesLaserVoltageLow PerceivedSeverityValue,
|
|
oaStatesLaserVoltageHigh PerceivedSeverityValue,
|
|
-- ** Only for amplifiers of raman type (see oaDisplayAmplifierIsRamanType) -
|
|
oaStatesRamanBackReflectionRatio PerceivedSeverityValue,
|
|
oaStatesRamanOscSignalMissing PerceivedSeverityValue
|
|
}
|
|
|
|
oaStatesBootloader OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The device is running in bootloader mode
|
|
without a legal application software."
|
|
::= { oaStatesEntry 1 }
|
|
|
|
oaStatesCommLoss OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The NEC has lost the connection to the device.
|
|
Reason may be a removed or defective device.
|
|
Note that this state is set by the NEC and not
|
|
by the device"
|
|
::= { oaStatesEntry 2 }
|
|
|
|
oaStatesInitializing OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The device is initializing"
|
|
::= { oaStatesEntry 3 }
|
|
|
|
oaStatesLaserShutdown OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Lasers are shutdown, no optical output"
|
|
::= { oaStatesEntry 4 }
|
|
|
|
oaStatesTemperatureLow OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Device internal temperature low"
|
|
::= { oaStatesEntry 5 }
|
|
|
|
oaStatesTemperatureHigh OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Device internal temperature high"
|
|
::= { oaStatesEntry 6 }
|
|
|
|
oaStatesSystem OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Internal error occured"
|
|
::= { oaStatesEntry 7 }
|
|
|
|
oaStatesInputPwrLow OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Optical input power low"
|
|
::= { oaStatesEntry 8 }
|
|
|
|
oaStatesInputPwrHigh OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Optical input power high"
|
|
::= { oaStatesEntry 9 }
|
|
|
|
oaStatesOutputPwrOrGainLow OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Optical output power (or gain) low"
|
|
::= { oaStatesEntry 10 }
|
|
|
|
oaStatesOutputPwrOrGainHigh OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Optical output power (or gain) high"
|
|
::= { oaStatesEntry 11 }
|
|
|
|
oaStatesReturnLossLow OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Return loss low"
|
|
::= { oaStatesEntry 12 }
|
|
|
|
oaStatesReturnLossHigh OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Return loss high"
|
|
::= { oaStatesEntry 13 }
|
|
|
|
oaStatesRedundancySwitch OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This (redundant) device has been activated (redundancy switchover)"
|
|
::= { oaStatesEntry 14 }
|
|
|
|
oaStatesInputVoltageLow OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input supply voltage low"
|
|
::= { oaStatesEntry 15 }
|
|
|
|
oaStatesInputVoltageHigh OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Input supply voltage high"
|
|
::= { oaStatesEntry 16 }
|
|
|
|
-- #####+8 Space reserved for additional states
|
|
|
|
oaStatesPowerSupplyLeft OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The left (looking from front) power supply unit fails.
|
|
Only valid for devices in 19 inch housing"
|
|
::= { oaStatesEntry 25 }
|
|
|
|
oaStatesPowerSupplyRight OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The right (looking from front) power supply unit fails.
|
|
Only valid for devices in 19 inch housing"
|
|
::= { oaStatesEntry 26 }
|
|
|
|
oaStatesFanLeft OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The left (looking from front) fan unit fails.
|
|
Only valid for devices in 19 inch housing"
|
|
::= { oaStatesEntry 27 }
|
|
|
|
oaStatesFanRight OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The right (looking from front) fan unit fails.
|
|
Only valid for devices in 19 inch housing"
|
|
::= { oaStatesEntry 28 }
|
|
|
|
oaStatesInternalVoltageLow OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "One (or more) internal voltages low"
|
|
::= { oaStatesEntry 29 }
|
|
|
|
oaStatesInternalVoltageHigh OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "One (or more) internal voltages high"
|
|
::= { oaStatesEntry 30 }
|
|
|
|
oaStatesLaserCurrentLow OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Laser current of one (or more) lasers low"
|
|
::= { oaStatesEntry 31 }
|
|
|
|
oaStatesLaserCurrentHigh OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Laser current of one (or more) lasers high (laser is aging)"
|
|
::= { oaStatesEntry 32 }
|
|
|
|
oaStatesTecCurrentLow OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Laser TEC current limit of one (or more) lasers reached (heating limit)"
|
|
::= { oaStatesEntry 33 }
|
|
|
|
oaStatesTecCurrentHigh OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Laser TEC current limit of one (or more) lasers reached (cooling limit)"
|
|
::= { oaStatesEntry 34 }
|
|
|
|
oaStatesLaserTempLow OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Laser temperature of one (or more) lasers low"
|
|
::= { oaStatesEntry 35 }
|
|
|
|
oaStatesLaserTempHigh OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Laser temperature of one (or more) lasers high"
|
|
::= { oaStatesEntry 36 }
|
|
|
|
oaStatesLaserVoltageLow OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Laser voltage supply of one (or more) lasers low"
|
|
::= { oaStatesEntry 37 }
|
|
|
|
oaStatesLaserVoltageHigh OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Laser voltage supply of one (or more) lasers high"
|
|
::= { oaStatesEntry 38 }
|
|
|
|
oaStatesRamanBackReflectionRatio OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Raman amplifier back reflection ratio high alarm
|
|
Only used if oaDisplayAmplifierIsRamanType == true(1)"
|
|
::= { oaStatesEntry 39 }
|
|
|
|
oaStatesRamanOscSignalMissing OBJECT-TYPE
|
|
SYNTAX PerceivedSeverityValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Raman amplifier oscillator signal missing alarm
|
|
Only used if oaDisplayAmplifierIsRamanType == true(1)"
|
|
::= { oaStatesEntry 40 }
|
|
|
|
--*****************************************************************************************
|
|
-- oaControl group
|
|
|
|
oaControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OaControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaControl 1 }
|
|
|
|
-- table of control entry(ro/rw)
|
|
|
|
oaControlEntry OBJECT-TYPE
|
|
SYNTAX OaControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "Alarms for a module."
|
|
INDEX { oaNESlot }
|
|
::= { oaControlTable 1 }
|
|
|
|
-- the structure of the entry
|
|
|
|
OaControlEntry ::= SEQUENCE
|
|
{
|
|
oaControlLaserShutdown TruthValue,
|
|
oaControlReset TruthValue,
|
|
oaControlModuleLedBlink TruthValue,
|
|
oaControlSbsEvaluationStart TruthValue
|
|
}
|
|
|
|
oaControlLaserShutdown OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Shutdown the laser(s), optical power on/off."
|
|
::= { oaControlEntry 1 }
|
|
|
|
oaControlReset OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Reset the module."
|
|
::= { oaControlEntry 2 }
|
|
|
|
oaControlModuleLedBlink OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Writing this variable to true(1) lets the device's
|
|
modul LED blink green for 10 seconds.
|
|
Writing this variable to false(2) stops blinking at once.
|
|
This variable always returns false(2) on read requests"
|
|
::= { oaControlEntry 3 }
|
|
|
|
oaControlSbsEvaluationStart OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting to true(1) starts an SBS threshold evaluation process.
|
|
Always reads as false(2)"
|
|
::={ oaControlEntry 4 }
|
|
|
|
|
|
--*****************************************************************************************
|
|
-- oaConfiguration group
|
|
|
|
oaConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OaConfigurationEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaConfiguration 1 }
|
|
|
|
-- table of configuration entry(ro/rw)
|
|
|
|
oaConfigurationEntry OBJECT-TYPE
|
|
SYNTAX OaConfigurationEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX { oaNESlot }
|
|
::= { oaConfigurationTable 1 }
|
|
|
|
-- the structure of the entry
|
|
|
|
OaConfigurationEntry ::= SEQUENCE
|
|
{
|
|
oaConfigNESlotWrite NESlotWriteValue,
|
|
oaConfigRegulationMode RegulationMode,
|
|
oaConfigOutputPwrOrGainAdjust INTEGER,
|
|
oaConfigModeExtIO ExtIOmode,
|
|
oaConfigMaskExtIO ExtIOmask,
|
|
oaConfigSbsEvaluationMode SbsEvaluationMode
|
|
}
|
|
|
|
oaConfigNESlotWrite OBJECT-TYPE
|
|
SYNTAX NESlotWriteValue
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION "By writing this variable a slot can be assigned
|
|
for devices that dont support hardware slot detection.
|
|
Reading '-1' means that the slot position is NOT writable."
|
|
::= { oaConfigurationEntry 1 }
|
|
|
|
oaConfigRegulationMode OBJECT-TYPE
|
|
SYNTAX RegulationMode
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The regulation mode of the device.
|
|
- regModeConstantOutputPower(1):
|
|
If the device runs in constant output power mode, then all *OutputPwrOrGain*
|
|
variables are interpreted as 'Output Power' specific.
|
|
- regModeConstantGain(2):
|
|
If the device runs in constant gain mode, then all *OutputPwrOrGain*
|
|
variables are interpreted as 'Gain' specific."
|
|
::={ oaConfigurationEntry 2 }
|
|
|
|
oaConfigOutputPwrOrGainAdjust OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable can be used to adjust the desired output power (or gain)
|
|
value in 0.1 dB units relative to its nominal level.
|
|
See oaConfigRegulationMode variable too"
|
|
::={ oaConfigurationEntry 3 }
|
|
|
|
oaConfigModeExtIO OBJECT-TYPE
|
|
SYNTAX ExtIOmode
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The mode and usage of the device's external IO port."
|
|
::= { oaConfigurationEntry 4 }
|
|
|
|
oaConfigMaskExtIO OBJECT-TYPE
|
|
SYNTAX ExtIOmask
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The alarm/warning mask that activates the device's external IO port."
|
|
::= { oaConfigurationEntry 5 }
|
|
|
|
oaConfigSbsEvaluationMode OBJECT-TYPE
|
|
SYNTAX SbsEvaluationMode
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The SBS threshold evaluation mode."
|
|
::={ oaConfigurationEntry 6 }
|
|
|
|
--*****************************************************************************************
|
|
-- Display group
|
|
|
|
oaDisplayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OaDisplayEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
::= { oaDisplay 1 }
|
|
|
|
-- table of configuration entry(ro/rw)
|
|
|
|
oaDisplayEntry OBJECT-TYPE
|
|
SYNTAX OaDisplayEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION ""
|
|
INDEX { oaNESlot }
|
|
::= { oaDisplayTable 1 }
|
|
|
|
-- the structure of the entry
|
|
|
|
OaDisplayEntry ::= SEQUENCE
|
|
{
|
|
oaDisplayNumberOfLasers INTEGER,
|
|
oaDisplayNumberOfInternalVoltages INTEGER,
|
|
oaDisplayExtIOSupported TruthValue,
|
|
oaDisplaySbsSupported TruthValue,
|
|
oaDisplayReturnLossSupported TruthValue,
|
|
oaDisplaySbsEvaluatedThreshold INTEGER,
|
|
oaDisplaySbsLastEvaluationState SbsEvaluationState,
|
|
oaDisplaySbsLastEvaluationTime DisplayString,
|
|
oaDisplayOutputPwrOrGainNominal INTEGER,
|
|
oaDisplayOutputPwrOrGainAdjusted INTEGER,
|
|
oaDisplayInputVoltageNominal INTEGER,
|
|
oaDisplayInternalVoltage1Nominal INTEGER,
|
|
oaDisplayInternalVoltage2Nominal INTEGER,
|
|
oaDisplayInternalVoltage3Nominal INTEGER,
|
|
oaDisplayLaser1VoltageNominal INTEGER,
|
|
oaDisplayLaser2VoltageNominal INTEGER,
|
|
oaDisplayLaser3VoltageNominal INTEGER,
|
|
oaDisplayLaser4VoltageNominal INTEGER,
|
|
oaDisplayLaser5VoltageNominal INTEGER,
|
|
oaDisplayLaser6VoltageNominal INTEGER,
|
|
oaDisplayLaser1PumpPowerRel INTEGER,
|
|
oaDisplayLaser2PumpPowerRel INTEGER,
|
|
oaDisplayLaser3PumpPowerRel INTEGER,
|
|
oaDisplayLaser4PumpPowerRel INTEGER,
|
|
oaDisplayLaser5PumpPowerRel INTEGER,
|
|
oaDisplayLaser6PumpPowerRel INTEGER,
|
|
oaDisplayLaser1FeaturesSupported LaserFeatures,
|
|
oaDisplayLaser2FeaturesSupported LaserFeatures,
|
|
oaDisplayLaser3FeaturesSupported LaserFeatures,
|
|
oaDisplayLaser4FeaturesSupported LaserFeatures,
|
|
oaDisplayLaser5FeaturesSupported LaserFeatures,
|
|
oaDisplayLaser6FeaturesSupported LaserFeatures,
|
|
oaDisplayAmplifierIsRamanType TruthValue
|
|
}
|
|
|
|
oaDisplayNumberOfLasers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of lasers used by this optical amplifier"
|
|
::={ oaDisplayEntry 1 }
|
|
|
|
oaDisplayNumberOfInternalVoltages OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The number of internal voltages monitored by this optical amplifier"
|
|
::={ oaDisplayEntry 2 }
|
|
|
|
oaDisplayExtIOSupported OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Return 'true(1)' if external I/O feature is supported by the device."
|
|
::= { oaDisplayEntry 3 }
|
|
|
|
oaDisplaySbsSupported OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Return 'true(1)' if SBS feature is supported by the device."
|
|
::= { oaDisplayEntry 4 }
|
|
|
|
oaDisplayReturnLossSupported OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Return 'true(1)' if ReturnLoss feature is supported by the device."
|
|
::= { oaDisplayEntry 5 }
|
|
|
|
oaDisplaySbsEvaluatedThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The evaluated SBS output power or gain threshold in 0.1 dB(m) units.
|
|
Not supported by all optical amplifiers"
|
|
::={ oaDisplayEntry 6 }
|
|
|
|
oaDisplaySbsLastEvaluationState OBJECT-TYPE
|
|
SYNTAX SbsEvaluationState
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The result of last SBS threshold evaluation process.
|
|
Returns 'evaluationNotSupported(1)' if SBS threshold evaluation
|
|
is not supported by this optical amplifier"
|
|
::={ oaDisplayEntry 7 }
|
|
|
|
oaDisplaySbsLastEvaluationTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time of last successfull SBS threshold evaluation process.
|
|
Not supported by all optical amplifiers"
|
|
::={ oaDisplayEntry 8 }
|
|
|
|
oaDisplayOutputPwrOrGainNominal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal value of output power (or gain) in 0.1 dB(m) units.
|
|
See oaConfigRegulationMode variable too"
|
|
::={ oaDisplayEntry 9 }
|
|
|
|
oaDisplayOutputPwrOrGainAdjusted OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The adjusted desired value of output power (or gain) in 0.1 dB(m) units.
|
|
See oaConfigRegulationMode variable too"
|
|
::={ oaDisplayEntry 10 }
|
|
|
|
oaDisplayInputVoltageNominal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The nominal value of input voltage in 0.1 V units."
|
|
::={ oaDisplayEntry 11 }
|
|
|
|
oaDisplayInternalVoltage1Nominal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The nominal value of internal voltage no. 1 in 0.1 V units."
|
|
::={ oaDisplayEntry 12 }
|
|
|
|
oaDisplayInternalVoltage2Nominal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The nominal value of internal voltage no. 2 in 0.1 V units."
|
|
::={ oaDisplayEntry 13 }
|
|
|
|
oaDisplayInternalVoltage3Nominal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The nominal value of internal voltage no. 3 in 0.1 V units."
|
|
::={ oaDisplayEntry 14 }
|
|
|
|
-- #####+5 Space reserved for 5 additional internal voltages
|
|
|
|
oaDisplayLaser1VoltageNominal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The nominal supply voltage of laser no.1 in 0.1 V units."
|
|
::={ oaDisplayEntry 20 }
|
|
|
|
oaDisplayLaser2VoltageNominal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The nominal supply voltage of laser no.2 in 0.1 V units."
|
|
::={ oaDisplayEntry 21 }
|
|
|
|
oaDisplayLaser3VoltageNominal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The nominal supply voltage of laser no.3 in 0.1 V units."
|
|
::={ oaDisplayEntry 22 }
|
|
|
|
oaDisplayLaser4VoltageNominal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The nominal supply voltage of laser no.4 in 0.1 V units."
|
|
::={ oaDisplayEntry 23 }
|
|
|
|
oaDisplayLaser5VoltageNominal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The nominal supply voltage of laser no.5 in 0.1 V units."
|
|
::={ oaDisplayEntry 24 }
|
|
|
|
oaDisplayLaser6VoltageNominal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The nominal supply voltage of laser no.6 in 0.1 V units."
|
|
::={ oaDisplayEntry 25 }
|
|
|
|
-- #####+4 Space reserved for 4 additional lasers
|
|
|
|
oaDisplayLaser1PumpPowerRel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The pump power of laser no.1 in steps of 0.1%"
|
|
::={ oaDisplayEntry 30 }
|
|
|
|
oaDisplayLaser2PumpPowerRel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The pump power of laser no.2 in steps of 0.1%"
|
|
::={ oaDisplayEntry 31 }
|
|
|
|
oaDisplayLaser3PumpPowerRel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The pump power of laser no.3 in steps of 0.1%"
|
|
::={ oaDisplayEntry 32 }
|
|
|
|
oaDisplayLaser4PumpPowerRel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The pump power of laser no.4 in steps of 0.1%"
|
|
::={ oaDisplayEntry 33 }
|
|
|
|
oaDisplayLaser5PumpPowerRel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The pump power of laser no.5 in steps of 0.1%"
|
|
::={ oaDisplayEntry 34 }
|
|
|
|
oaDisplayLaser6PumpPowerRel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The pump power of laser no.6 in steps of 0.1%"
|
|
::={ oaDisplayEntry 35 }
|
|
|
|
-- #####+4 Space reserved for 4 additional lasers
|
|
|
|
oaDisplayLaser1FeaturesSupported OBJECT-TYPE
|
|
SYNTAX LaserFeatures
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The features supported by laser no.1
|
|
A bitfield containing the features supplied by this laser.
|
|
Note that laserCurrent is always supplied."
|
|
::={ oaDisplayEntry 40 }
|
|
|
|
oaDisplayLaser2FeaturesSupported OBJECT-TYPE
|
|
SYNTAX LaserFeatures
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The features supported by laser no.2"
|
|
::={ oaDisplayEntry 41 }
|
|
|
|
oaDisplayLaser3FeaturesSupported OBJECT-TYPE
|
|
SYNTAX LaserFeatures
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The features supported by laser no.3"
|
|
::={ oaDisplayEntry 42 }
|
|
|
|
oaDisplayLaser4FeaturesSupported OBJECT-TYPE
|
|
SYNTAX LaserFeatures
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The features supported by laser no.4"
|
|
::={ oaDisplayEntry 43 }
|
|
|
|
oaDisplayLaser5FeaturesSupported OBJECT-TYPE
|
|
SYNTAX LaserFeatures
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The features supported by laser no.5"
|
|
::={ oaDisplayEntry 44 }
|
|
|
|
oaDisplayLaser6FeaturesSupported OBJECT-TYPE
|
|
SYNTAX LaserFeatures
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The features supported by laser no.6"
|
|
::={ oaDisplayEntry 45 }
|
|
|
|
-- #####+4 Space reserved for 4 additional lasers
|
|
|
|
oaDisplayAmplifierIsRamanType OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Returns true(1) if this amplifier is of RAMAN type"
|
|
::={ oaDisplayEntry 50 }
|
|
|
|
|
|
--*****************************************************************************************
|
|
END
|