mibs/MIBS/brocade/FOUNDRY-SN-POS-GROUP-MIB
2023-12-05 12:25:34 +01:00

1032 lines
24 KiB
Plaintext

FOUNDRY-SN-POS-GROUP-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,Counter32, Gauge32, Unsigned32,Integer32
FROM SNMPv2-SMI
router
FROM FOUNDRY-SN-ROOT-MIB
ifIndex
FROM IF-MIB
DisplayString,TEXTUAL-CONVENTION
FROM SNMPv2-TC;
snPOS MODULE-IDENTITY
LAST-UPDATED "201006020000Z" -- 04 June 2010
ORGANIZATION "Brocade Communications Systems, Inc."
CONTACT-INFO
"Technical Support Center
130 Holger Way,
San Jose, CA 95134
Email: ipsupport@brocade.com
Phone: 1-800-752-8061
URL: www.brocade.com"
DESCRIPTION
"Copyright 1996-2010 Brocade Communications Systems, Inc.
All rights reserved.
This Brocade Communications Systems SNMP Management Information Base Specification
embodies Brocade Communications Systems' confidential and proprietary
intellectual property. Brocade Communications Systems retains all
title and ownership in the Specification, including any revisions.
This Specification is supplied AS IS, and Brocade Communications Systems makes
no warranty, either express or implied, as to the use,
operation, condition, or performance of the specification, and any unintended
consequence it may on the user environment."
REVISION "201006020000Z" -- 04 June 2010
DESCRIPTION
"Changed the ORGANIZATION, CONTACT-INFO and DESCRIPTION fields."
REVISION "200909300000Z" -- September 30, 2009
DESCRIPTION
""
::= { router 14}
-- textual conventions
POSStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"
Status Values
"
SYNTAX INTEGER { disabled(0), enabled(1) }
snPOSInfo OBJECT IDENTIFIER ::= { snPOS 1 }
-- POS Port table information
snPOSInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnPOSInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A specific snPOSInfo group consists of a number of
switch ports. "
::= { snPOSInfo 1 }
snPOSInfoEntry OBJECT-TYPE
SYNTAX SnPOSInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the snPOSInfo table indicates the
configuration on a specified port. A SNMP SET PDU
for a row of the snPOSInfoTable requires the entired
sequence of the MIB Objects in each
snPOSInfoEntry stored in one PDU. Otherwise,
GENERR return-value will be returned."
INDEX {
snPOSInfoPortNum
}
::= { snPOSInfoTable 1 }
SnPOSInfoEntry ::= SEQUENCE {
snPOSInfoPortNum
Integer32,
snPOSIfIndex
Integer32,
snPOSDescr
DisplayString,
snPOSName
DisplayString,
snPOSInfoSpeed
INTEGER,
snPOSInfoAdminStatus
INTEGER,
snPOSInfoLinkStatus
INTEGER,
snPOSInfoClock
INTEGER,
snPOSInfoLoopBack
INTEGER,
snPOSInfoScrambleATM
POSStatus,
snPOSInfoFraming
INTEGER,
snPOSInfoCRC
INTEGER,
snPOSInfoKeepAlive
INTEGER,
snPOSInfoFlagC2
INTEGER,
snPOSInfoFlagJ0
INTEGER,
snPOSInfoFlagH1
INTEGER,
snPOSStatsInFrames
Counter32,
snPOSStatsOutFrames
Counter32,
snPOSStatsAlignErrors
Counter32,
snPOSStatsFCSErrors
Counter32,
snPOSStatsFrameTooLongs
Counter32,
snPOSStatsFrameTooShorts
Counter32,
snPOSStatsInDiscard
Counter32,
snPOSStatsOutDiscard
Counter32,
snPOSInOctets
OCTET STRING,
snPOSOutOctets
OCTET STRING,
snPOSStatsInBitsPerSec
Gauge32,
snPOSStatsOutBitsPerSec
Gauge32,
snPOSStatsInPktsPerSec
Gauge32,
snPOSStatsOutPktsPerSec
Gauge32,
snPOSStatsInUtilization
INTEGER ,
snPOSStatsOutUtilization
INTEGER ,
snPOSTagType
INTEGER,
snPOSStatsB1
Counter32,
snPOSStatsB2
Counter32,
snPOSStatsB3
Counter32,
snPOSStatsAIS
Counter32,
snPOSStatsRDI
Counter32,
snPOSStatsLOP
Counter32,
snPOSStatsLOF
Counter32,
snPOSStatsLOS
Counter32
}
snPOSInfoPortNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port index.
The bit 0 to bit 7: port number.
The bit 8 to bit 11: slot number (slot for chassis only)."
::= { snPOSInfoEntry 1 }
snPOSIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"In order to identify a particular interface, this
object shall identify the instance of the ifIndex
object, defined in RFC 1213 and RFC 1573."
::= { snPOSInfoEntry 2 }
snPOSDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing the slot/port information
about the interface."
::= { snPOSInfoEntry 3 }
snPOSName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Name string."
::= { snPOSInfoEntry 4 }
snPOSInfoSpeed OBJECT-TYPE
SYNTAX INTEGER {
s155000(1),
s622000(2),
other(3),
s2488000(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The speed configuration for a port. The values are:
155000
622000
2488000
"
::= { snPOSInfoEntry 5 }
snPOSInfoAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1), -- ready to pass packets
down(2),
testing(3) -- in some test mode
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The desired state of all ports. The
testing(3) state indicates that no operational
packets can be passed.
(same as ifAdminStatus in MIB-II)"
::= { snPOSInfoEntry 6 }
snPOSInfoLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1), -- ready to pass packets
down(2),
testing(3) -- in some test mode
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational state of the interface.
The testing(3) state indicates that no operational
packets can be passed.
(same as ifOperStatus in MIB-II)"
::= { snPOSInfoEntry 7 }
snPOSInfoClock OBJECT-TYPE
SYNTAX INTEGER {
internal(1),
line(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock default internal"
::= { snPOSInfoEntry 8 }
snPOSInfoLoopBack OBJECT-TYPE
SYNTAX INTEGER {
line(1),
internal(2),
none(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Loop back default none"
::= { snPOSInfoEntry 9 }
snPOSInfoScrambleATM OBJECT-TYPE
SYNTAX POSStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ATM style scrambling default off"
::= { snPOSInfoEntry 10 }
snPOSInfoFraming OBJECT-TYPE
SYNTAX INTEGER {
sonet(1),
sdh(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Framing default SONET"
::= { snPOSInfoEntry 11 }
snPOSInfoCRC OBJECT-TYPE
SYNTAX INTEGER {
crc32bits(1),
crc16bits(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CRC default 32 bit"
::= { snPOSInfoEntry 12 }
snPOSInfoKeepAlive OBJECT-TYPE
SYNTAX INTEGER (0..32767)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Keep-alive default 10"
::= { snPOSInfoEntry 13 }
snPOSInfoFlagC2 OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"C2 flag"
::= { snPOSInfoEntry 14 }
snPOSInfoFlagJ0 OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"J0 flag"
::= { snPOSInfoEntry 15 }
snPOSInfoFlagH1 OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"H1 flag"
::= { snPOSInfoEntry 16 }
snPOSStatsInFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received on the interface."
::= { snPOSInfoEntry 17 }
snPOSStatsOutFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets transmitted out of the interface."
::= { snPOSInfoEntry 18 }
snPOSStatsAlignErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"dot3StatsAlignmentErrors : A count of frames
received on a particular interface that are
not an integral number of octets in length
and do not pass the FCS check.
The count represented by an instance of this
object is incremented when the alignmentError
status is returned by the MAC service to the
LLC (or other MAC user). Received frames for
which multiple error conditions obtain are,
according to the conventions of IEEE 802.3
Layer Management, counted exclusively according
to the error status presented to the LLC."
::= { snPOSInfoEntry 19 }
snPOSStatsFCSErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"dot3StatsFCSErrors : A count of frames received
on a particular interface that are an integral
number of octets in length but do not pass the
FCS check.
The count represented by an instance of this
object is incremented when the frameCheckError
status is returned by the MAC service to the
LLC (or other MAC user). Received frames for
which multiple error conditions obtain are,
according to the conventions of IEEE 802.3
Layer Management, counted exclusively according
to the error status presented to the LLC."
::= { snPOSInfoEntry 20 }
snPOSStatsFrameTooLongs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"dot3StatsFrameTooLongs : A count of frames
received on a particular interface that
exceed the maximum permitted frame size.
The count represented by an instance of this
object is incremented when the frameTooLong
status is returned by the MAC service to the
LLC (or other MAC user). Received frames for
which multiple error conditions obtain are,
according to the conventions of IEEE 802.3
Layer Management, counted exclusively according
to the error status presented to the LLC."
::= { snPOSInfoEntry 21 }
snPOSStatsFrameTooShorts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" A count of frames received on a particular
interface that below the minimum permitted
frame size."
::= { snPOSInfoEntry 22 }
snPOSStatsInDiscard OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of inbound packets which were chosen
to be discarded even though no errors had been
detected to prevent their being deliverable to a
higher-layer protocol. One possible reason for
discarding such a packet could be to free up
buffer space."
::= { snPOSInfoEntry 23 }
snPOSStatsOutDiscard OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of outbound packets which were chosen
to be discarded even though no errors had been
detected to prevent their being transmitted. One
possible reason for discarding such a packet could
be to free up buffer space."
::= { snPOSInfoEntry 24 }
snPOSInOctets OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets received on the interface,
including framing characters. This object is a 64-bit
counter of the ifInOctets object, defined in RFC 1213.
The octet string is in big-endian byte order."
::= { snPOSInfoEntry 25 }
snPOSOutOctets OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets transmitted out of the interface,
including framing characters. This object is a 64-bit
counter of the ifOutOctets object, defined in RFC 1213.
The octet string is in big-endian byte order."
::= { snPOSInfoEntry 26 }
snPOSStatsInBitsPerSec OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bits per second received on the interface
over a 5 minutes interval."
::= { snPOSInfoEntry 27 }
snPOSStatsOutBitsPerSec OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bits per second transmitted out of the interface
over a 5 minutes interval."
::= { snPOSInfoEntry 28 }
snPOSStatsInPktsPerSec OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets per second received on the interface
over a 5 minutes interval."
::= { snPOSInfoEntry 29 }
snPOSStatsOutPktsPerSec OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets per second transmitted out of the interface
over a 5 minutes interval."
::= { snPOSInfoEntry 30 }
snPOSStatsInUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The input network utilization in hundredths of a percent
over a 5 minutes interval."
::= { snPOSInfoEntry 31 }
snPOSStatsOutUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The output network utilization in hundredths of a percent
over a 5 minutes interval."
::= { snPOSInfoEntry 32 }
snPOSTagType OBJECT-TYPE
SYNTAX INTEGER {
tagged(1),
untagged(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For tagged port, we could have multiple VLANs
per port."
::= {snPOSInfoEntry 33}
snPOSStatsB1 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Section error monitoring."
::= { snPOSInfoEntry 34 }
snPOSStatsB2 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Line error monitoring."
::= { snPOSInfoEntry 35 }
snPOSStatsB3 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Path error monitoring."
::= { snPOSInfoEntry 36 }
snPOSStatsAIS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm indication signal."
::= { snPOSInfoEntry 37 }
snPOSStatsRDI OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remote defect indication."
::= { snPOSInfoEntry 38 }
snPOSStatsLOP OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loss of pointer."
::= { snPOSInfoEntry 39 }
snPOSStatsLOF OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loss of frame."
::= { snPOSInfoEntry 40 }
snPOSStatsLOS OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loss of signal."
::= { snPOSInfoEntry 41 }
-- POS Port table information
snPOSInfo2Table OBJECT-TYPE
SYNTAX SEQUENCE OF SnPOSInfo2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An snPOSInfo2Table consists of a number of
SnPOSInfo2Entry entries"
::= { snPOSInfo 2 }
snPOSInfo2Entry OBJECT-TYPE
SYNTAX SnPOSInfo2Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the snPOSInfo2Table indicates the
POS configuration on a specified port"
INDEX {
ifIndex
}
::= { snPOSInfo2Table 1 }
SnPOSInfo2Entry ::= SEQUENCE {
snPOSInfo2Clock
INTEGER,
snPOSInfo2ScrambleATM
POSStatus,
snPOSInfo2CRC
INTEGER,
snPOSInfo2KeepAlive
Unsigned32,
snPOSInfo2FlagC2
Unsigned32,
snPOSInfo2SSM
INTEGER,
snPOSInfo2Encapsulation
INTEGER,
snPOSInfo2AlarmMonitoring
INTEGER,
snPOSInfo2OverheadJ0ExpectedMessage
OCTET STRING,
snPOSInfo2OverheadJ0TransmitMessage
OCTET STRING,
snPOSInfo2OverheadJ1ExpectedMessage
OCTET STRING,
snPOSInfo2OverheadJ1MessageLength
INTEGER,
snPOSInfo2OverheadJ1TransmitMessage
OCTET STRING
}
snPOSInfo2Clock OBJECT-TYPE
SYNTAX INTEGER {
internal(1),
line(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock source for the POS Interface
internal(1) - internal source
line (2) - clocking is derived from line"
DEFVAL { internal }
::= { snPOSInfo2Entry 1 }
snPOSInfo2ScrambleATM OBJECT-TYPE
SYNTAX POSStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ATM style scrambling for the POS interface
disabled(0) - scrambling is disabled
enabled(1) - scrambling is enabled"
DEFVAL { disabled }
::= { snPOSInfo2Entry 2 }
snPOSInfo2CRC OBJECT-TYPE
SYNTAX INTEGER {
crc32bits(1),
crc16bits(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Length of Cyclic Redundnacy Check (CRC) on the
POS interface
crc32bits(1) - 32 bits
crc16bits(2) - 16 buts"
DEFVAL { crc32bits }
::= { snPOSInfo2Entry 3 }
snPOSInfo2KeepAlive OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Keep-alive timer for the POS interface in seconds"
DEFVAL { 10 }
::= { snPOSInfo2Entry 4 }
snPOSInfo2FlagC2 OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"C2 flag"
::= { snPOSInfo2Entry 5 }
snPOSInfo2SSM OBJECT-TYPE
SYNTAX INTEGER {
t1SonetPrimaryReferenceSource(1) ,
t1SonetTraceabilityUnknown(2) ,
t1SonetStratum2Traceable(3) ,
t1SonetTransitNodeClock(4) ,
t1SonetStratum3eTraceable(5) ,
t1SonetStratum3Traceable(6) ,
t1SonetMinClockTraceable(7) ,
t1SonetDus(8) ,
e1SdhTraceabilityUnknown(9) ,
e1SdhSsmTransitNodeClockG812(10) ,
e1SdhDus(11) ,
e1SdhSsmPrimaryReferenceClockG811(12) ,
e1SdhSsmLocalG812(13) ,
e1SdhSsmSyncEquipmentTimingSource(14)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The S(ynchronization) S(tatus) M(essage) is sent over
the SONET/SDH line to tell the other end about the
quality of clock being sent over the line.
t1SonetPrimaryReferenceSource(1) - SONET Primary Reference Source
t1SonetTraceabilityUnknown(2} - SONET Traceability Unknown
t1SonetStratum2Traceable(3) - SONET Stratum 2 Traceable
t1SonetTransitNodeClock(4) - SONET Transit Node Clock
t1SonetStratum3eTraceable(5) - SONET Stratum 3e Traceable
t1SonetStratum3Traceable(6) - SONET Stratum 3 Traceable
t1SonetMinClockTraceable(7) - SONET Minimum Clock Traceable
t1SonetDus(8) - SONET Do not Use for Synchronization
e1SdhTraceabilityUnknown(9) - SDH Traceability Unknown
e1SdhSsmTransitNodeClockG812(10) - SDH Transit Node Clock G812
e1SdhDus(11) - SDH Do not Use for Synchronization
e1SdhSsmPrimaryReferenceClockG811(12) - SDH Primary Reference Clock G811
e1SdhSsmLocalG812(13) - SDH Local G812
e1SdhSsmSyncEquipmentTimingSource(14) - SDH Synchronization Equipment Timing Source"
DEFVAL { t1SonetTraceabilityUnknown }
::= { snPOSInfo2Entry 6 }
snPOSInfo2Encapsulation OBJECT-TYPE
SYNTAX INTEGER {
ppp(1),
hdlc(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Layer 2 encapsulation on the POS interface
ppp(1) - Point to Point Protocol (PPP)
hdlc(2) - Cisco High-level Data Link Control (cHDLC)"
DEFVAL { ppp }
::= { snPOSInfo2Entry 7 }
snPOSInfo2AlarmMonitoring OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Alarm Monitoring on POS interface
off(0) - Alarm Monitoring is off
on(1) - Alarm Montioring is on"
DEFVAL { on }
::= { snPOSInfo2Entry 8 }
snPOSInfo2OverheadJ0ExpectedMessage OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Overhead J0 Expected Message"
::= { snPOSInfo2Entry 9 }
snPOSInfo2OverheadJ0TransmitMessage OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Overhead J0 Transmit Message"
::= { snPOSInfo2Entry 10 }
snPOSInfo2OverheadJ1ExpectedMessage OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Overhead J1 Expected Message"
::= { snPOSInfo2Entry 11 }
snPOSInfo2OverheadJ1MessageLength OBJECT-TYPE
SYNTAX INTEGER {
s16 (16),
s64 (64)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Overhead J1 Length of Message
s16(16)...........16 bytes
s64(64)............64 bytes"
DEFVAL { s64 }
::= { snPOSInfo2Entry 12 }
snPOSInfo2OverheadJ1TransmitMessage OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Overhead J1 Transmit Message"
::= { snPOSInfo2Entry 13 }
-- POS PPP Group
-- If the L2 encapsulation is PPP, the following will provide
-- information on the states of various control protocols
snPOSPPPTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnPOSPPPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An snPOSPPPTable consists of a number of
SnPOSPPPEntry entries"
::= { snPOSInfo 3 }
snPOSPPPEntry OBJECT-TYPE
SYNTAX SnPOSPPPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the snPOSPPPTable indicates the
PPP control protocol status on a specified port"
INDEX {
ifIndex
}
::= { snPOSPPPTable 1 }
SnPOSPPPEntry ::= SEQUENCE {
snPosPppLcp
DisplayString,
snPosPppIpCp
DisplayString,
snPosPppIpv6Cp
DisplayString,
snPosPppOsInLcp
DisplayString,
snPosPppMpLscp
DisplayString
}
snPosPppLcp OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PPP Link Control Protocol state"
::= { snPOSPPPEntry 1 }
snPosPppIpCp OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PPP IP Control Protocol state"
::= { snPOSPPPEntry 2 }
snPosPppIpv6Cp OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PPP IPv6 Control Protocol state"
::= { snPOSPPPEntry 3 }
snPosPppOsInLcp OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PPP OSI Network Layer Control Protocol state"
::= { snPOSPPPEntry 4 }
snPosPppMpLscp OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PPP MPLS Control Protocol state"
::= { snPOSPPPEntry 5 }
-- POS cHDLC Group
-- If the L2 encapsulation is cHDLC, the following will provide
-- information various cHDLC paraemters
snPOScHDLCTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnPOScHDLCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An snPOScHDLCTable consists of a number of
SnPOScHDLCEntry entries"
::= { snPOSInfo 4 }
snPOScHDLCEntry OBJECT-TYPE
SYNTAX SnPOScHDLCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in snPOScHDLCEntry shows the
cHDLC information on a specified port"
INDEX {
ifIndex
}
::= { snPOScHDLCTable 1 }
SnPOScHDLCEntry ::= SEQUENCE {
snPOScHDLCLineState
INTEGER,
snPOScHDLCInLoopback
INTEGER,
snPOScHDLCMySeq
Unsigned32,
snPOScHDLCMySeqSeen
Unsigned32,
snPOScHDLCPeerSeqSeen
Unsigned32,
snPOScHDLCUniqueSent
Unsigned32,
snPOScHDLCUniqueReceived
Unsigned32
}
snPOScHDLCLineState OBJECT-TYPE
SYNTAX INTEGER {
down (0),
up (1),
unknown (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"cHDLC Line State"
::= { snPOScHDLCEntry 1 }
snPOScHDLCInLoopback OBJECT-TYPE
SYNTAX INTEGER {
no (0),
yes (1),
unknown (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"cHDLC in loopback"
::= { snPOScHDLCEntry 2 }
snPOScHDLCMySeq OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"cHDLC my sequence number"
::= { snPOScHDLCEntry 3 }
snPOScHDLCMySeqSeen OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"cHDLC my sequence number seen"
::= { snPOScHDLCEntry 4 }
snPOScHDLCPeerSeqSeen OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"cHDLC peer sequence number seen"
::= { snPOScHDLCEntry 5 }
snPOScHDLCUniqueSent OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"cHDLC unique sent"
::= { snPOScHDLCEntry 6 }
snPOScHDLCUniqueReceived OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"cHDLC unique received"
::= { snPOScHDLCEntry 7 }
END
-- *****************************************************************
-- Commited Access Rate MIB file.
-- *****************************************************************