mibs/MIBS/cambium/600/CAMBIUM-PTP600-MIB
2023-12-05 12:25:34 +01:00

3780 lines
134 KiB
Plaintext

CAMBIUM-PTP600-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Integer32, IpAddress,
enterprises
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
DisplayString
FROM SNMPv2-TC
InetAddress, InetAddressType
FROM INET-ADDRESS-MIB;
cambium MODULE-IDENTITY
LAST-UPDATED "201403041414Z"
ORGANIZATION "Cambium Networks Ltd."
CONTACT-INFO
"Post: Simon Whitaker
Cambium Networks Ltd.
Unit B2,
Linhay Business Park,
Eastern Road,
Ashburton,
Devon.
TQ13 7UP
United Kingdom
Phone: +44 (0) 1364 655 500
Email: simon.whitaker@cambiumnetworks.com"
DESCRIPTION
"MIB for 300Mbps non-line-of-sight (NLOS) wireless ethernet bridge."
REVISION "201403041414Z"
DESCRIPTION
"PTP600-10-07:
Reinstated incompatibleRegionCodesTrap.
Reinstated incompatibleMasterAndSlaveTrap.
Reinstated encryptionEnabledMismatchTrap."
REVISION "201309142338Z"
DESCRIPTION
"PTP600-10-06:
Removed incompatibleRegionCodesTrap.
Removed incompatibleMasterAndSlaveTrap.
Removed encryptionEnabledMismatchTrap."
REVISION "201208131812Z"
DESCRIPTION
"PTP600-10-04:
Added ethernetBridgingStatus, ethernetBridgingAvailability.
Added ethernetBridgingStatusAlarm, ethernetBridgingStatusAlarmTrap."
REVISION "201205011158Z"
DESCRIPTION
"PTP600-10-03: make linkName & groupID read-write."
REVISION "201202131238Z"
DESCRIPTION
"PTP600-10-01: Updated ORGANIZATION and CONTACT-INFO."
REVISION "201111081347Z"
DESCRIPTION
"PTP600-10-00:
Added new SNTP attributes, replace syslogLocalLog with syslogState. Add L2/L3 QoS attributes.
Added securityLevel. Renamed vLANPriorityQueueMapping with ethernetPriorityQueueMapping.
Added syslogClient and secureModeAlarm traps."
REVISION "201012071328Z"
DESCRIPTION "PTP600-09-10: Added searchState, accessMethod and groupID."
REVISION "201011021333Z"
DESCRIPTION "PTP600-09-02: Added latitude, longitude, altitude."
REVISION "201007161541Z"
DESCRIPTION
"PTP600-09-01:
Changed root OID.
Renamed ethernet & fiber attributes & traps.
Replaced vLANManagementVIDValidation with managementMode.
Added linkName, siteName, hTTPSAccessEnabled, tDDSynchronizationMode.
Added syslog attributes & traps.
Added SNMPTrapTable for dual trap receivers."
REVISION "201004231007Z"
DESCRIPTION "PTP600-08-50: Security enhancements."
REVISION "201002191855Z"
DESCRIPTION "PTP600-08-04: Added SNMPv3 support, DFS Table, Automatic Tx Power Control. BIT STRING types now OCTET STRING."
REVISION "200907101520Z"
DESCRIPTION "PTP600-08-03: Added VLAN Priority Table, more read-only attributes, plus alarm tidy-up."
REVISION "200902271711Z"
DESCRIPTION "PTP600-08-01: Improve TDD Synchronization status and alarms."
REVISION "200812151219Z"
DESCRIPTION "PTP600-08-00: Support 4.8 & 4.9 GHz variant & 20 MHz bandwidth, Link Symmetry, TDD Synchronization."
REVISION "200806301016Z"
DESCRIPTION "PTP600-07-00: Added IEEE 802.1q & 802.1ad VLAN support."
REVISION "200802290942Z"
DESCRIPTION "PTP600-06-00: Added OOB, HTTP & telnet access controls."
REVISION "200707311839Z"
DESCRIPTION "PTP600-05-00: Added groups, attributes and notifications for diagnostic alarms."
REVISION "200611231436Z"
DESCRIPTION "PTP600-04-00: Converted to SMIv2."
REVISION "200607241008Z"
DESCRIPTION "PTP600-03-01"
::= { enterprises 17713 }
-- Groups in cambium
ptp OBJECT IDENTIFIER ::= { cambium 1 }
ptmp OBJECT IDENTIFIER ::= { cambium 2 }
ptp600 OBJECT IDENTIFIER ::= { cambium 6 }
-- Groups in ptp600
dfs OBJECT IDENTIFIER ::= { ptp600 3 }
bridge OBJECT IDENTIFIER ::= { ptp600 4 }
configuration OBJECT IDENTIFIER ::= { ptp600 5 }
ethernet OBJECT IDENTIFIER ::= { ptp600 6 }
telecom OBJECT IDENTIFIER ::= { ptp600 7 }
licence OBJECT IDENTIFIER ::= { ptp600 8 }
management OBJECT IDENTIFIER ::= { ptp600 9 }
phyControl OBJECT IDENTIFIER ::= { ptp600 10 }
phyStatus OBJECT IDENTIFIER ::= { ptp600 12 }
alarms OBJECT IDENTIFIER ::= { ptp600 13 }
smtp OBJECT IDENTIFIER ::= { ptp600 15 }
snmpControl OBJECT IDENTIFIER ::= { ptp600 16 }
sntp OBJECT IDENTIFIER ::= { ptp600 17 }
reset OBJECT IDENTIFIER ::= { ptp600 18 }
versions OBJECT IDENTIFIER ::= { ptp600 19 }
pubStats OBJECT IDENTIFIER ::= { ptp600 20 }
encryption OBJECT IDENTIFIER ::= { ptp600 22 }
tDDControl OBJECT IDENTIFIER ::= { ptp600 23 }
aAAControl OBJECT IDENTIFIER ::= { ptp600 25 }
syslogControl OBJECT IDENTIFIER ::= { ptp600 24 }
supplementary OBJECT IDENTIFIER ::= { ptp600 96 }
ptpGroups OBJECT IDENTIFIER ::= { ptp600 98 }
ptpTraps OBJECT IDENTIFIER ::= { ptp600 99 }
ptpTrapPrefix OBJECT IDENTIFIER ::= { ptpTraps 0 }
-- Compliance information
--
ptpCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the Cambium PTP MIB"
MODULE -- this module
MANDATORY-GROUPS { dfsGroup
, bridgeGroup
, configurationGroup
, ethernetGroup
, telecomGroup
, licenceGroup
, managementGroup
, phyControlGroup
, phyStatusGroup
, alarmsGroup
, smtpGroup
, snmpControlGroup
, sntpGroup
, resetGroup
, versionsGroup
, pubStatsGroup
, encryptionGroup
, tDDControlGroup
, aAAControlGroup
, syslogControlGroup
, supplementaryGroup
, notificationsGroup
}
::= { ptp600 97 }
dfsGroup OBJECT-GROUP
OBJECTS { dfsTableNumber
, dfsMeans
, dfsNineNinePointNinePercentiles
, dfsPeaks
}
STATUS current
DESCRIPTION "The dfs object group."
::= { ptpGroups 3 }
bridgeGroup OBJECT-GROUP
OBJECTS { localPacketFiltering
}
STATUS current
DESCRIPTION "The bridge object group."
::= { ptpGroups 4 }
configurationGroup OBJECT-GROUP
OBJECTS { iPv4Address
, subnetMask
, gatewayIPAddress
, targetMACAddress
, masterSlaveMode
, maximumTransmitPower
, antennaGain
, cableLoss
, eIRP
, ethernetCappedMaxWirelessSpeed
, channelBandwidth
, remoteIPAddress
, linkName
, siteName
, accessMethod
, groupID
, iPv6Address
, iPVersion
, iPv6AutoConfiguredLinkLocalAddress
, iPv6PrefixLength
, iPv6GatewayAddress
, remoteInternetAddressType
, remoteInternetAddress
}
STATUS current
DESCRIPTION "The configuration object group."
::= { ptpGroups 5 }
ethernetGroup OBJECT-GROUP
OBJECTS { dataPortAutoNegotiation
, dataPortAutoNegAdvertisement
, dataPortAutoMdix
, dataPortStatus
, dataPortSpeedAndDuplex
, dataPortWirelessDownAlert
, useVLANForManagementInterfaces
, vLANManagementPriority
, vLANManagementVID
, managementPortStatus
, managementPortSpeedAndDuplex
, ethernetPriorityTableNumber
, l2CPPriorityTableNumber
, iPDSCPPriorityTableNumber
, mPLSTCPriorityTableNumber
, managementMode
, managementPortWirelessDownAlert
, qOSPriorityScheme
, unknownNetworkPriorityQueueMapping
, dSCPManagementPriority
, ethernetBridgingStatus
, ethernetPriorityQueueMapping
, l2CPPriorityQueueMapping
, iPDSCPPriorityQueueMapping
, mPLSTCPriorityQueueMapping
}
STATUS current
DESCRIPTION "The ethernet object group."
::= { ptpGroups 6 }
telecomGroup OBJECT-GROUP
OBJECTS { telecomsInterface
, telecomsChannelAStatus
, telecomsChannelBStatus
, channelALineCode
, channelBLineCode
, channelACableLength
, channelBCableLength
, channelALoopback
, channelBLoopback
, telecomsChannelSelection
}
STATUS current
DESCRIPTION "The telecom object group."
::= { ptpGroups 7 }
licenceGroup OBJECT-GROUP
OBJECTS { regionCode
, productVariant
, productName
, ethernetFiberSupport
, frequencyVariant
, bandwidthVariant
, constantPowerSpectralDensity
, sNMPv3Enable
, hAZLOCConfiguration
, securityLevel
}
STATUS current
DESCRIPTION "The licence object group."
::= { ptpGroups 8 }
managementGroup OBJECT-GROUP
OBJECTS { targetRange
, rangingMode
, installStatus
, installArmState
, tFTPServerIPAddress
, tFTPServerPortNumber
, tFTPSoftwareUpgradeFileName
, tFTPStartSoftwareUpgrade
, tFTPSoftwareUpgradeStatus
, tFTPSoftwareUpgradeStatusText
, tFTPSoftwareUpgradeStatusAdditionalText
, hTTPAccessEnabled
, telnetAccessEnabled
, hTTPPortNumber
, hTTPSPortNumber
, telnetPortNumber
, hTTPSAccessEnabled
, tFTPServerInternetAddressType
, tFTPServerInternetAddress
}
STATUS current
DESCRIPTION "The management object group."
::= { ptpGroups 9 }
phyControlGroup OBJECT-GROUP
OBJECTS { linkSymmetry
, linkModeOptimisation
, userConfiguredMaxModulationMode
, remoteMaximumTransmitPower
, txColorCode
, rxColorCode
, automaticTxPowerControl
, remoteRxTargetPower
}
STATUS current
DESCRIPTION "The phyControl object group."
::= { ptpGroups 10 }
phyStatusGroup OBJECT-GROUP
OBJECTS { receivePower
, vectorError
, transmitPower
, range
, linkLoss
, receiveChannel
, transmitChannel
, receiveModulationMode
, transmitModulationMode
, receiveFreqMHz
, transmitFreqMHz
, signalStrengthRatio
, receiveFreqKHz
, transmitFreqKHz
, searchState
, rawReceivePower
}
STATUS current
DESCRIPTION "The phyStatus object group."
::= { ptpGroups 12 }
alarmsGroup OBJECT-GROUP
OBJECTS { unitOutOfCalibration
, incompatibleRegionCodes
, noWirelessChannelAvailable
, wirelessLinkDisabledWarning
, dataPortDisabledWarning
, dataPortFiberStatus
, dataPortConfigurationMismatch
, incompatibleMasterAndSlave
, tDDSynchronizationStatus
, managementPortDisabledWarning
, tDDSynchronizationAlarm
, linkModeOptimizationMismatch
, managementPortConfigurationMismatch
, secureModeAlarm
, ethernetBridgingStatusAlarm
}
STATUS current
DESCRIPTION "The alarms object group."
::= { ptpGroups 13 }
smtpGroup OBJECT-GROUP
OBJECTS { sMTPEmailAlert
, sMTPServerIPAddress
, sMTPServerPortNumber
, sMTPSourceEmailAddress
, sMTPDestinationEmailAddress
, sMTPEnabledMessages
, sMTPServerInternetAddressType
, sMTPServerInternetAddress
}
STATUS current
DESCRIPTION "The smtp object group."
::= { ptpGroups 15 }
snmpControlGroup OBJECT-GROUP
OBJECTS { sNMPPortNumber
, sNMPCommunityString
, sNMPTrapTableNumber
, sNMPTrapVersion
, sNMPEnabledTraps
, enabledDiagnosticAlarms
, sNMPSendAllTrapsAtStartup
, sNMPTrapIPAddress
, sNMPTrapPortNumber
, sNMPTrapInternetAddressType
, sNMPTrapInternetAddress
, sNMPTrapReceiverEnabled
}
STATUS current
DESCRIPTION "The snmpControl object group."
::= { ptpGroups 16 }
sntpGroup OBJECT-GROUP
OBJECTS { sNTPState
, sNTPPollInterval
, sNTPSync
, sNTPLastSync
, systemClock
, timeZone
, daylightSaving
, sNTPPrimaryServer
, sNTPPrimaryServerDeadTime
, sNTPServerRetries
, sNTPServerTimeout
, sNTPServerTableNumber
, sNTPServerIPAddress
, sNTPServerPortNumber
, sNTPServerStatus
, sNTPServerInternetAddressType
, sNTPServerInternetAddress
}
STATUS current
DESCRIPTION "The sntp object group."
::= { ptpGroups 17 }
resetGroup OBJECT-GROUP
OBJECTS { systemReset
}
STATUS current
DESCRIPTION "The reset object group."
::= { ptpGroups 18 }
versionsGroup OBJECT-GROUP
OBJECTS { softwareVersion
, hardwareVersion
, secondarySoftwareVersion
, bootVersion
}
STATUS current
DESCRIPTION "The versions object group."
::= { ptpGroups 19 }
pubStatsGroup OBJECT-GROUP
OBJECTS { receiveDataRate
, transmitDataRate
, aggregateDataRate
, wirelessLinkAvailability
, wirelessLinkStatus
, byteErrorRatio
, receiveModulationModeDetail
, ethernetBridgingAvailability
}
STATUS current
DESCRIPTION "The pubStats object group."
::= { ptpGroups 20 }
encryptionGroup OBJECT-GROUP
OBJECTS { encryptionAlgorithm
}
STATUS current
DESCRIPTION "The encryption object group."
::= { ptpGroups 22 }
tDDControlGroup OBJECT-GROUP
OBJECTS { tDDSynchronizationMode
}
STATUS current
DESCRIPTION "The tDDControl object group."
::= { ptpGroups 23 }
aAAControlGroup OBJECT-GROUP
OBJECTS { userTableNumber
, userName
, userRole
, userEnabled
, userPassword
}
STATUS current
DESCRIPTION "The aAAControl object group."
::= { ptpGroups 25 }
syslogControlGroup OBJECT-GROUP
OBJECTS { syslogClient
, syslogState
}
STATUS current
DESCRIPTION "The syslogControl object group."
::= { ptpGroups 24 }
supplementaryGroup OBJECT-GROUP
OBJECTS { longitude
, latitude
, altitude
}
STATUS current
DESCRIPTION "The supplementary object group."
::= { ptpGroups 96 }
notificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS { channelChangeTrap
, dfsImpulsiveInterferenceTrap
, dataPortStatusTrap
, telecomsChannelAStatusTrap
, telecomsChannelBStatusTrap
, channelALoopbackTrap
, channelBLoopbackTrap
, regionCodeTrap
, installStatusTrap
, installArmStateTrap
, unitOutOfCalibrationTrap
, incompatibleRegionCodesTrap
, noWirelessChannelAvailableTrap
, wirelessLinkDisabledWarningTrap
, dataPortDisabledWarningTrap
, dataPortFiberStatusTrap
, dataPortConfigurationMismatchTrap
, incompatibleMasterAndSlaveTrap
, sNTPSyncTrap
, tDDSynchronizationAlarmTrap
, managementPortStatusTrap
, managementPortDisabledWarningTrap
, linkModeOptimizationMismatchTrap
, managementPortConfigurationMismatchTrap
, syslogStateTrap
, syslogLocalNearlyFullTrap
, syslogLocalWrappedTrap
, syslogClientTrap
, secureModeAlarmTrap
, ethernetBridgingStatusAlarmTrap
}
STATUS current
DESCRIPTION "The notifications group."
::= { ptpGroups 99 }
DfsTableEntry ::=
SEQUENCE { dfsTableIndex INTEGER
, dfsMeans Integer32
, dfsNineNinePointNinePercentiles Integer32
, dfsPeaks Integer32
}
dfsTable OBJECT-TYPE
SYNTAX SEQUENCE OF DfsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A table storing a snapshot of various DFS measurements for each channel"
::= { dfs 2 }
dfsTableEntry OBJECT-TYPE
SYNTAX DfsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table DfsTable"
INDEX { dfsTableIndex }
::= { dfsTable 1 }
EthernetPriorityTableEntry ::=
SEQUENCE { ethernetPriorityTableIndex INTEGER
, ethernetPriorityQueueMapping INTEGER
}
ethernetPriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthernetPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A priority queue mapping table. This is a list of packet queues indexed by Ethernet priority."
::= { ethernet 15 }
ethernetPriorityTableEntry OBJECT-TYPE
SYNTAX EthernetPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table EthernetPriorityTable"
INDEX { ethernetPriorityTableIndex }
::= { ethernetPriorityTable 1 }
L2CPPriorityTableEntry ::=
SEQUENCE { l2CPPriorityTableIndex INTEGER
, l2CPPriorityQueueMapping INTEGER
}
l2CPPriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF L2CPPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A priority queue mapping table. This is a list of packet queues indexed by L2CP priority."
::= { ethernet 17 }
l2CPPriorityTableEntry OBJECT-TYPE
SYNTAX L2CPPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table L2CPPriorityTable"
INDEX { l2CPPriorityTableIndex }
::= { l2CPPriorityTable 1 }
IPDSCPPriorityTableEntry ::=
SEQUENCE { iPDSCPPriorityTableIndex INTEGER
, iPDSCPPriorityQueueMapping INTEGER
}
iPDSCPPriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF IPDSCPPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A priority queue mapping table. This is a list of packet queues indexed by L3 IP DSCP priority."
::= { ethernet 19 }
iPDSCPPriorityTableEntry OBJECT-TYPE
SYNTAX IPDSCPPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table IPDSCPPriorityTable"
INDEX { iPDSCPPriorityTableIndex }
::= { iPDSCPPriorityTable 1 }
MPLSTCPriorityTableEntry ::=
SEQUENCE { mPLSTCPriorityTableIndex INTEGER
, mPLSTCPriorityQueueMapping INTEGER
}
mPLSTCPriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF MPLSTCPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A priority queue mapping table. This is a list of priority queues indexed by MPLS TC priority."
::= { ethernet 21 }
mPLSTCPriorityTableEntry OBJECT-TYPE
SYNTAX MPLSTCPriorityTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table MPLSTCPriorityTable"
INDEX { mPLSTCPriorityTableIndex }
::= { mPLSTCPriorityTable 1 }
SNMPTrapTableEntry ::=
SEQUENCE { sNMPTrapTableIndex INTEGER
, sNMPTrapIPAddress IpAddress
, sNMPTrapPortNumber INTEGER
, sNMPTrapInternetAddressType INTEGER
, sNMPTrapInternetAddress InetAddress
, sNMPTrapReceiverEnabled INTEGER
}
sNMPTrapTable OBJECT-TYPE
SYNTAX SEQUENCE OF SNMPTrapTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" SNMP trap configuration table."
::= { snmpControl 4 }
sNMPTrapTableEntry OBJECT-TYPE
SYNTAX SNMPTrapTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table SNMPTrapTable"
INDEX { sNMPTrapTableIndex }
::= { sNMPTrapTable 1 }
SNTPServerTableEntry ::=
SEQUENCE { sNTPServerTableIndex INTEGER
, sNTPServerIPAddress IpAddress
, sNTPServerPortNumber INTEGER
, sNTPServerStatus DisplayString
, sNTPServerInternetAddressType INTEGER
, sNTPServerInternetAddress InetAddress
}
sNTPServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF SNTPServerTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { sntp 15 }
sNTPServerTableEntry OBJECT-TYPE
SYNTAX SNTPServerTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table SNTPServerTable"
INDEX { sNTPServerTableIndex }
::= { sNTPServerTable 1 }
UserTableEntry ::=
SEQUENCE { userTableIndex INTEGER
, userName OCTET STRING
, userRole INTEGER
, userEnabled INTEGER
, userPassword OCTET STRING
}
userTable OBJECT-TYPE
SYNTAX SEQUENCE OF UserTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The User Table Control group contains objects specifically for user account management."
::= { aAAControl 2 }
userTableEntry OBJECT-TYPE
SYNTAX UserTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table UserTable"
INDEX { userTableIndex }
::= { userTable 1 }
-- Dfs group attribute definitions
--
dfsTableNumber OBJECT-TYPE
SYNTAX INTEGER (1..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the dfsTable"
::= { dfs 1 }
-- DfsTable group attribute definitions
--
dfsTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"used to index values in the dfsTable."
::= { dfsTableEntry 1 }
dfsMeans OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Snapshot of DFS means"
::= { dfsTableEntry 2 }
dfsNineNinePointNinePercentiles OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Snapshot of DFS 99.9 percentiles"
::= { dfsTableEntry 3 }
dfsPeaks OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Snapshot of DFS peaks"
::= { dfsTableEntry 4 }
-- Bridge group attribute definitions
--
localPacketFiltering OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Local Packet Filtering is Enabled, the bridge
learns the source MAC addresses of devices transmitting
Ethernet packets on the local Ethernet network, and only
bridges packets to the remote unit if the destination MAC
address has not been learnt as a 'local' device. When
Local Packet Filtering is Disabled then the bridge does
not learn the source MAC addresses of devices
transmitting Ethernet packets on the local Ethernet
network, and bridges ALL Ethernet packets received to the
remote unit. Local Packet Filtering should be enabled if
no external routing hardware is present"
::= { bridge 1 }
-- Configuration group attribute definitions
--
iPv4Address OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Internet protocol (IPv4) address. This address is used
by the family of Internet protocols to uniquely identify
the unit on a network. NB: A system reboot is required to
activate changes to this attribute."
::= { configuration 1 }
subnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A subnet allows the flow of network traffic between
hosts to be segregated based on a network configuration.
By organizing hosts into logical groups, subnetting can
improve network security and performance. NB: A system
reboot is required to activate changes to this attribute"
::= { configuration 2 }
gatewayIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv4 address of a computer on the current network
that is currently acting as an IPv4 network gateway. A
gateway acts as an entrance / exit to packets from / to
other networks. NB: A system reboot is required to
activate changes to this attribute"
::= { configuration 3 }
targetMACAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the PTP wireless unit forming the other
end of the PTP link"
::= { configuration 4 }
masterSlaveMode OBJECT-TYPE
SYNTAX INTEGER {
master(0),
slave(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The PTP wireless link operates using a master and slave
relationship"
::= { configuration 5 }
maximumTransmitPower OBJECT-TYPE
SYNTAX INTEGER (-15..27)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum transmit power the wireless unit is permitted to
use when establishing and maintaining the wireless link"
::= { configuration 6 }
antennaGain OBJECT-TYPE
SYNTAX INTEGER (0..610)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Antenna Gain. Expressed in 10ths of dBi. NB: This
attribute is ignored for variants with an integral
antenna."
::= { configuration 7 }
cableLoss OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Loss in the cable between the ODU and the antenna.
Expressed in 10ths of dB. NB: This attribute is ignored
for variants with an integral antenna."
::= { configuration 8 }
eIRP OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Effective Isotropic Radiated Power (EIRP) describes the
strength of the radio signal leaving the wireless unit.
Expressed in 10ths of dBm"
::= { configuration 9 }
ethernetCappedMaxWirelessSpeed OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet frames will be discarded in the ODU if the data
rate over the wireless link exceeds the Ethernet link
speed at the local or remote Data port. The Ethernet
Capped Max Wireless Speed control limits the wireless
data rate based on the local and remote Ethernet link
speed. Set this control to Enabled if either ODU is
connected to an Ethernet link operating at less than 1000
Mbps. NB: This attribute is automatically disabled when
the installation agent is armed. To disarm the
installation agent use the installation wizard."
::= { configuration 10 }
channelBandwidth OBJECT-TYPE
SYNTAX INTEGER {
bw30MHz(0),
bw15MHz(1),
bw10MHz(2),
bw5MHz(3),
bw20MHz(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This control sets the bandwidth of the transmit and
receive radio channels"
::= { configuration 11 }
remoteIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP Address of the peer wireless unit"
::= { configuration 12 }
linkName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of the PTP link allocated by the System
Administrator. Used to establish a connection with the
correct PTP wireless unit at the other end of the link.
NOTE: The link name MUST be the same at both ends of the
PTP link."
::= { configuration 14 }
siteName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field contains a user-provided description of the
site name together with any additional notes"
::= { configuration 15 }
accessMethod OBJECT-TYPE
SYNTAX INTEGER {
linkAccess(0),
linkNameAccess(1),
groupAccess(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODUs must be configured in pairs before a link can be
established. The Access Method attribute determines how
the paired ODUs will recognise each other. For the Link
Access method, each ODU must be configured with Target
MAC Address equal to the MAC Address of the other unit.
For the Link Name Access method, both units must be
configured with the same Link Name. For the Group Access
method, both units must be configured with the same Group
ID."
::= { configuration 16 }
groupID OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Access Method is set to Group Access, the Group ID
identifies all the units belonging to the same group"
::= { configuration 17 }
iPv6Address OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..39))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Internet protocol (IPv6) address. This address is used
by the family of Internet protocols to uniquely identify
the unit on a network. NB: A system reboot is required to
activate changes to this attribute."
::= { configuration 18 }
iPVersion OBJECT-TYPE
SYNTAX INTEGER {
iPv4(0),
iPv6(1),
dualIPv4andIPv6(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP protocol selection. Choice of IPv4, IPv6 or Dual."
::= { configuration 20 }
iPv6AutoConfiguredLinkLocalAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..39))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The auto configured link local IPv6 address"
::= { configuration 21 }
iPv6PrefixLength OBJECT-TYPE
SYNTAX INTEGER (0..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IPv6 prefix length"
::= { configuration 22 }
iPv6GatewayAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..39))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv6 address of a computer on the current network
that is currently acting as an IPv6 network gateway. A
gateway acts as an entrance / exit to packets from / to
other networks. Note that it is usual to use the
link-local address of the gateway. NB: A system reboot is
required to activate changes to this attribute"
::= { configuration 23 }
remoteInternetAddressType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
ipv4(1),
ipv6(2),
ipv4z(3),
ipv6z(4),
unknown6(5),
unknown7(6),
unknown8(7),
unknown9(8),
unknown10(9),
unknown11(10),
unknown12(11),
unknown13(12),
unknown14(13),
unknown15(14),
unknown16(15),
dns(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Internet address specified by the associated
remoteInternetAddressType."
::= { configuration 24 }
remoteInternetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"INET address used to identify the peer wireless unit"
::= { configuration 25 }
-- Ethernet group attribute definitions
--
dataPortAutoNegotiation OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether the local Ethernet interface
configuration is automatically negotiated or forced. Do
not use a forced setting together with auto negotiation
at the Ethernet link partner. If you want to run your
Ethernet link at a fixed speed and duplex then you would
normally leave auto negotiation enabled and only enable
the single Auto Neg Advertisement option that you want
the link to run in - FORCING ETHERNET CONFIGURATION IS A
LAST RESORT WHICH SHOULD ONLY BE PERFORMED IF YOU ARE
HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST
ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE ETHERNET
LINK PARTNER TO WHICH IT IS CONNECTED IDENTICALLY (THE
LINK PARTNER MUST NOT HAVE AUTO NEGOTIATION ENABLED
EITHER, OTHERWISE A DUPLEX MISMATCH WILL OCCUR). NB: The
new setting will only take effect after a system reboot."
::= { ethernet 1 }
dataPortAutoNegAdvertisement OBJECT-TYPE
SYNTAX BITS {
negInvalid(2),
neg10MbpsHalfDuplex(3),
neg10MbpsFullDuplex(4),
neg100MbpsHalfDuplex(5),
neg100MbpsFullDuplex(6),
neg1000MbpsFullDuplex(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This sets the different Ethernet configurations that
will be advertised during auto negotiation. Note the new
setting will only take effect after a system reboot.
WARNING: Duplex mismatch may result if both ends of the
Ethernet link do not have the same settings. Do not auto
negotiation together with a fixed setting at the Ethernet
link partner. WARNING: Make sure that you select
option(s) that you know your connected equipment can
cater for!"
::= { ethernet 2 }
dataPortAutoMdix OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This enables/disables the Auto MDI/MDIX capability. NB:
The new setting will only take effect after a system
reboot"
::= { ethernet 3 }
dataPortStatus OBJECT-TYPE
SYNTAX INTEGER {
down(0),
copperLinkUp(1),
fiberLinkUp(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of the Ethernet link. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ethernet 4 }
dataPortSpeedAndDuplex OBJECT-TYPE
SYNTAX INTEGER {
speed1000MbpsFullDuplex(0),
speed100MbpsFullDuplex(1),
speed100MbpsHalfDuplex(2),
speed10MbpsFullDuplex(3),
speed10MbpsHalfDuplex(4),
speedUnknown6(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current speed and duplex of the Ethernet link"
::= { ethernet 5 }
dataPortWirelessDownAlert OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled, this causes the Ethernet link to be
dropped briefly when the wireless link drops. This is so
that spanning tree algorithms can quickly detect that
there is a problem."
::= { ethernet 6 }
useVLANForManagementInterfaces OBJECT-TYPE
SYNTAX INTEGER {
noVLANTagging(0),
iEEE8021QTaggedCTagType8100(1),
iEEE8021adTaggedSTagorBTagType88a8(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether the management interfaces
(WWW/SNMP/SMTP/SNTP) use VLAN tags or not. NB: The new
setting will only take effect after a system reboot"
::= { ethernet 7 }
vLANManagementPriority OBJECT-TYPE
SYNTAX INTEGER {
p0(0),
p1(1),
p2(2),
p3(3),
p4(4),
p5(5),
p6(6),
p7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This VLAN Priority (0-7) will be included in packets
generated by the management interfaces. NB: The new
setting will only take effect after a system reboot"
::= { ethernet 8 }
vLANManagementVID OBJECT-TYPE
SYNTAX INTEGER (0..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This VLAN VID (0-4094) will be included in packets
generated by the management interfaces. Note the new
setting will only take effect after a system reboot"
::= { ethernet 11 }
managementPortStatus OBJECT-TYPE
SYNTAX INTEGER {
down(0),
copperLinkUp(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of the out-of-band management link. NB: a
change of state may generate an SNMP trap and/or SMTP
email alert"
::= { ethernet 12 }
managementPortSpeedAndDuplex OBJECT-TYPE
SYNTAX INTEGER {
speed100MbpsFullDuplex(1),
speed100MbpsHalfDuplex(2),
speed10MbpsFullDuplex(3),
speed10MbpsHalfDuplex(4),
speedUnknown6(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current speed and duplex of the out-of-band
management link"
::= { ethernet 13 }
ethernetPriorityTableNumber OBJECT-TYPE
SYNTAX INTEGER (9)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the vLANPriorityTable."
::= { ethernet 14 }
l2CPPriorityTableNumber OBJECT-TYPE
SYNTAX INTEGER (5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the l2CPPriorityTable."
::= { ethernet 16 }
iPDSCPPriorityTableNumber OBJECT-TYPE
SYNTAX INTEGER (64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the iPDSCPPriorityTable."
::= { ethernet 18 }
mPLSTCPriorityTableNumber OBJECT-TYPE
SYNTAX INTEGER (8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the mPLSTCPriorityTable."
::= { ethernet 20 }
managementMode OBJECT-TYPE
SYNTAX INTEGER {
outofBandLocal(0),
outofBand(1),
inBand(2),
inBandLocal(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Out-of-Band Management (only available on certain
hardware models): End-to-end out-of-band mode in which
the management agent can be reached from the management
port at the local ODU and (assuming that the wireless
link is established) the management port at the remote
ODU. Out-of-Band Local Management (only available on
certain hardware models): Similar to the standard
Out-of-Band mode, except that management frames are not
forwarded over the wireless link. In-Band Management
(default): The management agent can be reached from the
data port at the local ODU and (assuming that the
wireless link is established) the data port at the remote
ODU. In this mode the management port is disabled.
In-Band Local Management (only available when 'Use VLAN
For Management Interfaces' configures a VLAN tag):
Similar to the standard In-Band mode, except that
management frames are not forwarded over the wireless
link."
::= { ethernet 22 }
managementPortWirelessDownAlert OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When enabled, this causes the management link to be
dropped briefly when the wireless link drops. This is so
that spanning tree algorithms can quickly detect that
there is a problem."
::= { ethernet 23 }
qOSPriorityScheme OBJECT-TYPE
SYNTAX INTEGER {
ethernet(0),
iPMPLS(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects classification based on fields in the Ethernet
header (Layer 2) or in the Network header (Layer 3). The
unit recognises two network layer protocols: IP and MPLS"
::= { ethernet 24 }
unknownNetworkPriorityQueueMapping OBJECT-TYPE
SYNTAX INTEGER {
q0(0),
q1(1),
q2(2),
q3(3),
q4(4),
q5(5),
q6(6),
q7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the classification of unknown network
protocols to an egress queue at the wireless port.
Unknown means something other than IP and MPLS"
::= { ethernet 25 }
dSCPManagementPriority OBJECT-TYPE
SYNTAX INTEGER (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This Differentiated Services Code Point value will be
inserted in the IP Header of all IP Datagrams transmitted
by the management interfaces"
::= { ethernet 26 }
ethernetBridgingStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of Ethernet packet bridging over the
wireless link"
::= { ethernet 27 }
-- EthernetPriorityTable group attribute definitions
--
ethernetPriorityTableIndex OBJECT-TYPE
SYNTAX INTEGER {
p0(1),
p1(2),
p2(3),
p3(4),
p4(5),
p5(6),
p6(7),
p7(8),
untagged(9)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ethernet priority flag, used to index values in the
ethernetPriorityTable"
::= { ethernetPriorityTableEntry 1 }
ethernetPriorityQueueMapping OBJECT-TYPE
SYNTAX INTEGER {
q0(0),
q1(1),
q2(2),
q3(3),
q4(4),
q5(5),
q6(6),
q7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the classification of this Ethernet priority
(also known as IEEE 802.1p value) to an egress queue at
the wireless port"
::= { ethernetPriorityTableEntry 2 }
-- L2CPPriorityTable group attribute definitions
--
l2CPPriorityTableIndex OBJECT-TYPE
SYNTAX INTEGER {
bridge(1),
mRP(2),
cFM(3),
rAPS(4),
eAPS(5)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"L2CP priority flag, used to index values in the
l2CPPriorityTable"
::= { l2CPPriorityTableEntry 1 }
l2CPPriorityQueueMapping OBJECT-TYPE
SYNTAX INTEGER {
q0(0),
q1(1),
q2(2),
q3(3),
q4(4),
q5(5),
q6(6),
q7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the classification of this layer two control
protocol (L2CP) to an egress queue at the wireless port"
::= { l2CPPriorityTableEntry 2 }
-- IPDSCPPriorityTable group attribute definitions
--
iPDSCPPriorityTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"IP DSCP priority flag, used to index values in the
iPDSCPPriorityTable"
::= { iPDSCPPriorityTableEntry 1 }
iPDSCPPriorityQueueMapping OBJECT-TYPE
SYNTAX INTEGER {
q0(0),
q1(1),
q2(2),
q3(3),
q4(4),
q5(5),
q6(6),
q7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the classification of this IP differentiated
services code point (DSCP) value to an egress queue at
the wireless port"
::= { iPDSCPPriorityTableEntry 2 }
-- MPLSTCPriorityTable group attribute definitions
--
mPLSTCPriorityTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MPLS TC priority flag, used to index values in the
mPLSTCPriorityTable"
::= { mPLSTCPriorityTableEntry 1 }
mPLSTCPriorityQueueMapping OBJECT-TYPE
SYNTAX INTEGER {
q0(0),
q1(1),
q2(2),
q3(3),
q4(4),
q5(5),
q6(6),
q7(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the classification of this MPLS traffic class
(the field formerly known as EXP) to an egress queue at
the wireless port"
::= { mPLSTCPriorityTableEntry 2 }
-- Telecom group attribute definitions
--
telecomsInterface OBJECT-TYPE
SYNTAX INTEGER {
none(0),
e1(1),
t1(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The line interface type. If this is set to 'None' then
the telecoms interfaces are disabled, and the telecom
group attributes will be ignored."
::= { telecom 1 }
telecomsChannelAStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
noSignalLocal(1),
noSignalRemote(2),
noSignalLocalandRemote(3),
up(4),
remoteTiming(5),
noSignalLocalandRemoteTiming(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of telecoms channel A. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { telecom 2 }
telecomsChannelBStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
noSignalLocal(1),
noSignalRemote(2),
noSignalLocalandRemote(3),
up(4),
remoteTiming(5),
noSignalLocalandRemoteTiming(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of telecoms channel B. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { telecom 3 }
channelALineCode OBJECT-TYPE
SYNTAX INTEGER {
aMI(0),
b8ZSHDB3(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The line code setting of the telecoms interface. This
must match the setting of the device connected to this
interface"
::= { telecom 4 }
channelBLineCode OBJECT-TYPE
SYNTAX INTEGER {
aMI(0),
b8ZSHDB3(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The line code setting of the telecoms interface. This
must match the setting of the device connected to this
interface"
::= { telecom 5 }
channelACableLength OBJECT-TYPE
SYNTAX INTEGER {
feet133(0),
feet266(1),
feet399(2),
feet533(3),
feet655(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The length of the cable connected to the telecoms
interface, measured in feet"
::= { telecom 6 }
channelBCableLength OBJECT-TYPE
SYNTAX INTEGER {
feet133(0),
feet266(1),
feet399(2),
feet533(3),
feet655(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The length of the cable connected to the telecoms
interface, measured in feet"
::= { telecom 7 }
channelALoopback OBJECT-TYPE
SYNTAX INTEGER {
none(0),
copper(1),
wireless(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The loopback status of telecoms channel A. This is
intended for installation testing and should be set to
'None' for normal operation. The wire connections to a
unit can be tested by applying a 'Copper' loopback to the
local unit. The wireless connection to the remote unit
can be tested by applying a 'Wireless' loopback to the
remote unit with no loopback on the local unit. NB: a
change of state may generate an SNMP trap and/or SMTP
email alert"
::= { telecom 8 }
channelBLoopback OBJECT-TYPE
SYNTAX INTEGER {
none(0),
copper(1),
wireless(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The loopback status of telecoms channel B. This is
intended for installation testing and should be set to
'None' for normal operation. The wire connections to a
unit can be tested by applying a 'Copper' loopback to the
local unit. The wireless connection to the remote unit
can be tested by applying a 'Wireless' loopback to the
remote unit with no loopback on the local unit. NB: a
change of state may generate an SNMP trap and/or SMTP
email alert"
::= { telecom 9 }
telecomsChannelSelection OBJECT-TYPE
SYNTAX INTEGER {
channelAOnly(0),
channelsAandB(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates which telecoms channels have been enabled. If
only Channel A has been enabled, then the Channel B
attributes will be ignored."
::= { telecom 10 }
-- Licence group attribute definitions
--
regionCode OBJECT-TYPE
SYNTAX INTEGER {
regionCodeInvalid(0),
regionCode1(1),
regionCode2(2),
regionCode3(3),
regionCode4(4),
regionCode5(5),
regionCode6(6),
regionCode7(7),
regionCode8(8),
regionCode9(9),
regionCode10(10),
regionCode11(11),
regionCode12(12),
regionCode13(13),
regionCode14(14),
regionCode15(15),
regionCode16(16),
regionCode17(17),
regionCode18(18),
regionCode19(19),
regionCode20(20),
regionCode21(21),
regionCode22(22),
regionCode23(23),
regionCode24(24),
regionCode25(25),
regionCode26(26),
regionCode27(27),
regionCode28(28),
regionCode29(29),
regionCode30(30),
regionCode31(31)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The region code prohibits the wireless unit from
operating outside the regulated limits. An invalid region
code indicates a corrupted license key. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { licence 1 }
productVariant OBJECT-TYPE
SYNTAX INTEGER {
pTPxx400Full(0),
pTPxx400Deprecated1(1),
pTPxx400Deprecated2(2),
pTPxx400Lite(3),
spare1(4),
pTPxx300(5),
spare2(6),
spare3(7),
pTPxx500FullDeprecated(8),
pTPxx500LiteDeprecated(9),
pTPxx500(10),
pTPxx600Lite(11),
pTPxx600Full(12),
spare5(13),
spare6(14),
pTP800(15)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The product variant"
::= { licence 2 }
productName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the product variant"
::= { licence 3 }
ethernetFiberSupport OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ethernet fiber support availability on this wireless
unit"
::= { licence 4 }
frequencyVariant OBJECT-TYPE
SYNTAX INTEGER {
freq5800MHz(0),
freq5400MHz(1),
freq4900MHz(2),
freq2500MHz(3),
freq5800MHz2(4),
freq5400MHz2(5),
freq4500MHz(6),
freq5900MHz(7),
freq5200MHz(8),
freq5100MHz(9),
freq4800MHz(10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frequency variant of the wireless unit"
::= { licence 5 }
bandwidthVariant OBJECT-TYPE
SYNTAX INTEGER {
bw30MHz(0),
bw15MHz(1),
bw10MHz(2),
bw5MHz(3),
bw20MHz(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bandwidth variant of the wireless unit"
::= { licence 6 }
constantPowerSpectralDensity OBJECT-TYPE
SYNTAX INTEGER {
constant(0),
fullPower(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Constant power spectral density mode control"
::= { licence 7 }
sNMPv3Enable OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SNMPv3 availability control"
::= { licence 9 }
hAZLOCConfiguration OBJECT-TYPE
SYNTAX INTEGER {
nonHAZLOCUnit(0),
gasGroupA(1),
gasGroupB(2),
gasGroupC(3),
gasGroupD(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The HAZLOC/ATEX Configuration of this unit. The Gas
Group is configured by the license key."
::= { licence 10 }
securityLevel OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
fIPS(1),
uCAPL(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum configurable security level"
::= { licence 11 }
-- Management group attribute definitions
--
targetRange OBJECT-TYPE
SYNTAX INTEGER (0..2000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Initial target range used in installation +/-1,
expressed in tenths of a kilometer. When Auto-Ranging
this must be set to 0"
::= { management 1 }
rangingMode OBJECT-TYPE
SYNTAX INTEGER {
auto0to40km(0),
auto0to100km(1),
auto0to200km(2),
targetRange(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of ranging to use during installation, either
Auto-Ranging or use a selectable Target Range"
::= { management 2 }
installStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
wrongPeer(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A non-zero value indicates that signalling was received
with the wrong MAC address or a mismatched link name. NB:
It is very unusual to detect this, because units with
mis-configured Target MAC Address will normally fail to
establish a wireless link. However, rare circumstances
may establish a partial wireless link and detect this
situation. NB: A non-zero value on start-up, or a change
of value during operation, may generate an SNMP trap
and/or SMTP email alert"
::= { management 3 }
installArmState OBJECT-TYPE
SYNTAX INTEGER {
disarmed(0),
armed(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if the unit is being installed. NB: a change
of state may generate an SNMP trap and/or SMTP email
alert"
::= { management 4 }
tFTPServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP address of the TFTP Server from which the TFTP
Software Upgrade File Name will be retrieved"
::= { management 5 }
tFTPServerPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port number of the TFTP Server from which the TFTP
Software Upgrade File Name will be retrieved"
::= { management 6 }
tFTPSoftwareUpgradeFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Filename of the Software Upgrade to be loaded from the
TFTP Server"
::= { management 7 }
tFTPStartSoftwareUpgrade OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Write '1' to this attribute to start the TFTP software
upgrade process. The attribute will be reset to 0 when
the upgrade process has finished. Continuing with the
software upgrade will cause spectrum management (DSO)
channel metrics collection to stop. The wireless unit
will no longer search for the optimal operational radio
channel. The performance of this wireless link may
deterioate over time. If operating in a region where
RADAR detection is mandatory you must complete the
software upgrade and reboot the unit. Channel metrics
collection will only be restarted after the wireless unit
has been rebooted"
::= { management 8 }
tFTPSoftwareUpgradeStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(0),
uploadinprogress(1),
uploadsuccessfulprogrammingFLASH(2),
upgradesuccessfulreboottorunthenewsoftwareimage(3),
upgradefailed(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of the TFTP Software upgrade process"
::= { management 9 }
tFTPSoftwareUpgradeStatusText OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Descriptive text describing the status of the TFTP
Software upgrade process, including any error details"
::= { management 10 }
tFTPSoftwareUpgradeStatusAdditionalText OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Any additional text describing the status of the TFTP
Software upgrade process, including any error details"
::= { management 11 }
hTTPAccessEnabled OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether or not HTTP access is enabled,
i.e. if this is disabled (0) then the unit will not
respond to any requests on the HTTP port. Remote
management via HTTPS is not affected by this setting. Any
change in this setting will not take effect until the
unit has been rebooted. (Factory default = Enabled)"
::= { management 12 }
telnetAccessEnabled OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether or not Telnet access is enabled,
i.e. if this is disabled (0) then the unit will not
respond to any requests on the TELNET port. Any change in
this setting will not take effect until the unit has been
rebooted. (Factory default = Disabled)"
::= { management 13 }
hTTPPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls the port number for HTTP access. A value
of zero will use the default port number. Any change in
this setting will not take effect until the unit has been
rebooted. (Factory default = 80)"
::= { management 14 }
hTTPSPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls the port number for HTTPS access. A value
of zero will use the default port number. Availability of
HTTPS is controlled via the License Key. Any change in
this setting will not take effect until the unit has been
rebooted. (Factory default = 443)"
::= { management 15 }
telnetPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls the port number for TELNET access. A value
of zero will use the default port number. Any change in
this setting will not take effect until the unit has been
rebooted. (Factory default = 23)"
::= { management 16 }
hTTPSAccessEnabled OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls whether or not HTTPS access is enabled,
i.e. if this is disabled (0) then the unit will not
respond to any requests on the HTTPS port. Remote
management via HTTP is not affected by this setting. Any
change in this setting will not take effect until the
unit has been rebooted. (Factory default = Enabled)"
::= { management 17 }
tFTPServerInternetAddressType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
ipv4(1),
ipv6(2),
ipv4z(3),
ipv6z(4),
unknown6(5),
unknown7(6),
unknown8(7),
unknown9(8),
unknown10(9),
unknown11(10),
unknown12(11),
unknown13(12),
unknown14(13),
unknown15(14),
unknown16(15),
dns(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Internet address specified by the associated
tFTPServerInternetAddress."
::= { management 18 }
tFTPServerInternetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"INET address of the TFTP Server from which the TFTP
Software Upgrade File Name will be retrieved"
::= { management 19 }
-- PhyControl group attribute definitions
--
linkSymmetry OBJECT-TYPE
SYNTAX INTEGER {
symmetryAdaptive(0),
symmetry2to1(1),
symmetry1to1(2),
symmetry1to2(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link Symmetry: in fixed symmetric mode the master spends
an equal amount of time transmitting and receiving; in
fixed asymmetric modes the master transmit and receive
times have a fixed ratio; in adaptive mode the transmit
and receive periods adjust with applied load."
::= { phyControl 1 }
linkModeOptimisation OBJECT-TYPE
SYNTAX INTEGER {
iPTraffic(0),
tDMTraffic(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optimises the wireless link behavior for the type of
traffic to be carried. In 'IP Traffic' mode, the wireless
link will minimise transmission errors by automatically
adapting the modulation mode. In 'TDM Traffic' mode, the
wireless link will minimise transmission latency and
preserve throughput by maintaining a higher modulation
mode in the presence of a limited number of errors. The
'TDM Traffic' mode is recommended for E1/T1 applications
and connectionless protocols."
::= { phyControl 2 }
userConfiguredMaxModulationMode OBJECT-TYPE
SYNTAX INTEGER {
modBpsk63percent(0),
modQpsk63percent(1),
modQpsk87percent(2),
mod16qam63percent(3),
mod16qam87percent(4),
mod64qam75percent(5),
mod64qam92percent(6),
mod256qam81percent(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum receive modulation mode controls the MAX
mode used for adaptive modulation. NOTE: This attribute
is automatically disabled when the installation agent is
armed. To disarm the installation agent use the
installation wizard"
::= { phyControl 3 }
remoteMaximumTransmitPower OBJECT-TYPE
SYNTAX INTEGER (-15..27)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum transmit power the remote wireless unit is
permitted to use when establishing and maintaining the
wireless link"
::= { phyControl 4 }
txColorCode OBJECT-TYPE
SYNTAX INTEGER {
a(0),
b(1),
c(2),
d(3),
e(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmit Color Code. This attribute need only be
considered when the unit is installed in a network of
PTP600 units and where some of the units are operating on
the same frequency. In this case, the value would
normally be derived by a network planner. In all other
cases, it is recommended that this attribute is left at
the default value. NOTE: For the link to operate, the
value of this parameter must in all cases match the value
of the Rx Color Code parameter at the far end of the
link."
::= { phyControl 5 }
rxColorCode OBJECT-TYPE
SYNTAX INTEGER {
a(0),
b(1),
c(2),
d(3),
e(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receive Color Code. This attribute need only be
considered when the unit is installed in a network of
PTP600 units and where some of the units are operating on
the same frequency. In this case, the value would
normally be derived by a network planner. In all other
cases, it is recommended that this attribute is left at
the default value. NOTE: For the link to operate, the
value of this parameter must in all cases match the value
of the Tx Color Code parameter at the far end of the
link."
::= { phyControl 6 }
automaticTxPowerControl OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1),
enabledwithinitialestimate(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When enabled, the transmit power of the local end is
automatically adjusted to maintain a configurable target
receive signal level at the remote end of the link. When
set to Enable with initial estimate, the Slave estimates
the optional transmit power before it responds to the
Master."
::= { phyControl 8 }
remoteRxTargetPower OBJECT-TYPE
SYNTAX INTEGER (-600..-400)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the target receive level for the end of the link
which is remote from the end being configured. When
Automatic Power Control is enabled, the transmit power of
the local end is automatically adjusted in order to
maintain the receive signal level at the remote end
within a range centered on this value"
::= { phyControl 9 }
-- PhyStatus group attribute definitions
--
receivePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receive power expressed in tenths of a dBm"
::= { phyStatus 1 }
vectorError OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vector error measurement compares the received
signal's IQ modulation characteristics to an ideal signal
to determine the composite error vector magnitude. The
value represented by this attribute is the average vector
error over the previous second expressed in tenths of a
dB"
::= { phyStatus 2 }
transmitPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transmit power expressed in tenths of a dBm"
::= { phyStatus 3 }
range OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Distance between the two peer wireless units expressed
in tenths of a kilometer"
::= { phyStatus 4 }
linkLoss OBJECT-TYPE
SYNTAX INTEGER (-500..500)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The wireless link loss expressed in tenths of a dB"
::= { phyStatus 5 }
receiveChannel OBJECT-TYPE
SYNTAX INTEGER (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active receive channel"
::= { phyStatus 6 }
transmitChannel OBJECT-TYPE
SYNTAX INTEGER (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active transmit channel"
::= { phyStatus 7 }
receiveModulationMode OBJECT-TYPE
SYNTAX INTEGER {
modAcquisition(0),
modBpsk63percent(1),
modQpsk63percentSingle(2),
modTransient1(3),
modQpsk87percentSingle(4),
modTransient2(5),
mod16qam63percentSingleA(6),
modTransient3(7),
mod16qam87percentSingle(8),
modTransient4(9),
mod64qam75percentSingle(10),
modTransient5(11),
mod64qam92percentSingle(12),
modTransient6(13),
mod256qam81percentSingle(14),
mod16qam63percentSingleB(15),
mod16qam63percentDual(16),
modTransient7(17),
mod16qam87percentDual(18),
modTransient8(19),
mod64qam75percentDual(20),
modTransient9(21),
mod64qam92percentDual(22),
modTransient10(23),
mod256qam81percentDual(24)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active receive modulation mode"
::= { phyStatus 8 }
transmitModulationMode OBJECT-TYPE
SYNTAX INTEGER {
modAcquisition(0),
modBpsk63percent(1),
modQpsk63percentSingle(2),
modTransient1(3),
modQpsk87percentSingle(4),
modTransient2(5),
mod16qam63percentSingleA(6),
modTransient3(7),
mod16qam87percentSingle(8),
modTransient4(9),
mod64qam75percentSingle(10),
modTransient5(11),
mod64qam92percentSingle(12),
modTransient6(13),
mod256qam81percentSingle(14),
mod16qam63percentSingleB(15),
mod16qam63percentDual(16),
modTransient7(17),
mod16qam87percentDual(18),
modTransient8(19),
mod64qam75percentDual(20),
modTransient9(21),
mod64qam92percentDual(22),
modTransient10(23),
mod256qam81percentDual(24)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current active transmit modulation mode"
::= { phyStatus 9 }
receiveFreqMHz OBJECT-TYPE
SYNTAX INTEGER (0..5925)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current receive frequency expressed in integer MHz"
::= { phyStatus 11 }
transmitFreqMHz OBJECT-TYPE
SYNTAX INTEGER (0..5925)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current transmit frequency expressed in integer MHz"
::= { phyStatus 12 }
signalStrengthRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal strength ratio (Vertical / Horizontal) : the
number of dB larger the Vertical antenna input is than
the Horizontal antenna input expressed in tenths of a dB"
::= { phyStatus 13 }
receiveFreqKHz OBJECT-TYPE
SYNTAX INTEGER (0..5925000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current receive frequency expressed as KHz"
::= { phyStatus 14 }
transmitFreqKHz OBJECT-TYPE
SYNTAX INTEGER (0..5925000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current transmit frequency expressed as KHz"
::= { phyStatus 15 }
searchState OBJECT-TYPE
SYNTAX INTEGER {
registering(0),
searching(1),
acquiring(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Search status of the wireless modem. 'Registering' means
that the modem has locked to an OFDM signal, and the
wireless link is up. 'Searching' means that no wireless
signal has been detected. 'Acquiring' means that a
wireless signal has been detected, but the modem has not
locked to an OFDM signal."
::= { phyStatus 16 }
rawReceivePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Raw receive power expressed in tenths of a dBm"
::= { phyStatus 17 }
-- Alarms group attribute definitions
--
unitOutOfCalibration OBJECT-TYPE
SYNTAX INTEGER {
calibrated(0),
outOfCalibration(1),
outOfCalibrationPAsShutdown(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit is out of calibration"
::= { alarms 1 }
incompatibleRegionCodes OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
incompatibleLicenceKeys(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The master and slave units have incompatible region
codes. NB: Both units must have compatible license keys"
::= { alarms 4 }
noWirelessChannelAvailable OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
noWirelessChannelAvailable(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Spectrum Management was unable to locate a suitable
wireless channel to operate on"
::= { alarms 5 }
wirelessLinkDisabledWarning OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
disabledBySNMPifAdminStatus(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the wireless interface has
disabled wireless traffic"
::= { alarms 6 }
dataPortDisabledWarning OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
disabledBySNMPifAdminStatus(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the Ethernet interface has
disabled Ethernet traffic"
::= { alarms 7 }
dataPortFiberStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
installedFiberNotLicensed(1),
fiberLinkNotEstablishedButLOSNotDetected(2),
fiberLinkNotEstablishedAndLOSDetected(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the fiber link is not OK, there are three possible
causes: Either the fiber link has been installed but
disabled (because the license key does not include fiber
support), the link could not be established even though
no LOS was detected (i.e. an optical carrier was
detected, which could be due to a broken TX fiber, or
because the link is disabled at the fiber link partner),
or the link could not be established and LOS is detected
(i.e. no optical carrier is detected). NB: a change of
status may generate an SNMP trap and/or SMTP email alert"
::= { alarms 8 }
dataPortConfigurationMismatch OBJECT-TYPE
SYNTAX INTEGER {
noError(0),
mismatchDetected(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The detection of Ethernet fragments (runt packets) when
the link is in full duplex is an indication of an
auto-negotiation or forced configuration mismatch"
::= { alarms 9 }
incompatibleMasterAndSlave OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
incompatibleProductVariants(1),
differentSoftwareVersionsRunning(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A non-zero value indicates that the master and slave
ends of a link are different hardware products, or have
different software versions. NB: It is very unusual to
detect this, because incompatible units will normally
fail to establish a wireless link. However, some
combinations may establish a partial wireless link and
detect this situation. NB: A non-zero value may generate
an SNMP trap and/or SMTP email alert"
::= { alarms 10 }
tDDSynchronizationStatus OBJECT-TYPE
SYNTAX INTEGER {
locked(0),
holdover(1),
holdoverNotConnected(2),
acquiringLock(3),
noTimingReference(4),
timingSystemNotConnected(5),
initialising(6),
clusterTimingMaster(7),
tDDSyncNotActive(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An alarm value (displayed in red) indicates that one of
the following conditions has not been met (i) An external
timing system is connected or internal timing has been
configured. (ii) The timing system is providing a useable
reference. (iii) The ODU is locked to this reference."
::= { alarms 11 }
managementPortDisabledWarning OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
disabledBySNMPifAdminStatus(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the out-of-band management
interface has disabled Ethernet traffic"
::= { alarms 12 }
tDDSynchronizationAlarm OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
notSynchronized(1),
timingSystemFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Not Synchronized indicates failure of the external
timing system for a period greater than the holdover
timer. TDD frame timing will have drifted, and this link
may cause interference with other links in a synchronized
network. Timing System Failure is an early warning,
indicating that 80% of the holdover period has expired."
::= { alarms 13 }
linkModeOptimizationMismatch OBJECT-TYPE
SYNTAX INTEGER {
ok(0),
linkModeOptimizationMismatch(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The remote node of this link has been configured with a
different link mode optimization"
::= { alarms 14 }
managementPortConfigurationMismatch OBJECT-TYPE
SYNTAX INTEGER {
noError(0),
mismatchDetected(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The detection of Ethernet fragments (runt packets) when
the link is in full duplex is an indication of an
auto-negotiation or forced configuration mismatch. This
alarm is only raised if an Out-of-Band Management Mode
has been configured."
::= { alarms 15 }
secureModeAlarm OBJECT-TYPE
SYNTAX INTEGER {
secureModeIsActive(0),
secureModeIsNotConfigured(1),
secureModeIsConfiguredButNotActive(2),
secureModeIsNotSupported(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The secure mode (e.g. FIPS, UC-APL) state of the unit.
The secure mode is not configured(1) state indicates that
the unit is capable of secure mode operation, and one or
more of the following security materials has not been
configured: Key Of Keys, Private Key, Public Certificate,
DRNG Entropy Status, Wireless Encryption Key. The secure
mode mode is configured but not active(2) state indicates
that the unit is capable of secure mode operation, and
the security material has been configured, but the
configuration of interfaces is not consistent with secure
mode operation. The secure mode is not supported(3) state
indicates that the unit is not capable of secure mode
operation. The secure mode capability requires
appropriate hardware compatibility, license key and
software image."
::= { alarms 16 }
ethernetBridgingStatusAlarm OBJECT-TYPE
SYNTAX INTEGER {
ethernetBridgingEnabled(0),
ethernetBridgingDisabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ethernet traffic bridging is disabled because the
wireless link is not operating at the configured Lowest
Ethernet Modulation Mode"
::= { alarms 17 }
-- Smtp group attribute definitions
--
sMTPEmailAlert OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Simple Mail Transfer Protocol is used to send equipment
alerts via email to a specified email address"
::= { smtp 1 }
sMTPServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP address of the SMTP server"
::= { smtp 2 }
sMTPServerPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port number of the SMTP server"
::= { smtp 3 }
sMTPSourceEmailAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The 'from' email address used when constructing the
automatically generated e-mail message"
::= { smtp 4 }
sMTPDestinationEmailAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The 'to' email address used when constructing the
automatically generated e-mail message"
::= { smtp 5 }
sMTPEnabledMessages OBJECT-TYPE
SYNTAX BITS {
telecomsChannelUpDown(1),
managementPortUpDown(2),
dataPortUpDown(3),
enabledDiagnosticAlarms(4),
dFSImpulseInterference(5),
channelChange(6),
wirelessLinkUpDown(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls which SMTP messages the unit will send"
::= { smtp 6 }
sMTPServerInternetAddressType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
ipv4(1),
ipv6(2),
ipv4z(3),
ipv6z(4),
unknown6(5),
unknown7(6),
unknown8(7),
unknown9(8),
unknown10(9),
unknown11(10),
unknown12(11),
unknown13(12),
unknown14(13),
unknown15(14),
unknown16(15),
dns(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Internet address specified by the associated
sMTPServerInternetAddress."
::= { smtp 7 }
sMTPServerInternetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Internet address of the SMTP server"
::= { smtp 8 }
-- SnmpControl group attribute definitions
--
sNMPPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP port number used to access the SNMP MIB (i.e.
Gets and Sets) (default = 161). NB: A system reboot is
required to activate changes to this attribute"
::= { snmpControl 1 }
sNMPCommunityString OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SNMP community string. NB: A system reboot is
required to activate changes to this attribute"
::= { snmpControl 2 }
sNMPTrapTableNumber OBJECT-TYPE
SYNTAX INTEGER (2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the sNMPTrapTable."
::= { snmpControl 3 }
sNMPTrapVersion OBJECT-TYPE
SYNTAX INTEGER {
v1(0),
v2c(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SNMP protocol version to use for SNMP Traps. NB: A
system reboot is required to activate changes to this
attribute"
::= { snmpControl 5 }
sNMPEnabledTraps OBJECT-TYPE
SYNTAX BITS {
managementPortUpDown(0),
dataPortUpDown(1),
authenticationFailure(2),
enabledDiagnosticAlarms(3),
dFSImpulseInterference(4),
channelChange(5),
wirelessLinkUpDown(6),
coldStart(7),
telecomsChannelUpDown(15)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls which SNMP Traps the unit will send"
::= { snmpControl 6 }
enabledDiagnosticAlarms OBJECT-TYPE
SYNTAX BITS {
incompatibleMasterAndSlave(0),
incompatibleRegionCodes(1),
unknown6(2),
unknown5(3),
unitOutOfCalibration(4),
installArmState(5),
installStatus(6),
regionCode(7),
telecomsChannelAStatus(8),
dataPortFiberStatus(9),
dataPortStatus(10),
dataPortDisabledWarning(11),
wirelessLinkDisabledWarning(12),
sNTPSynchronizationFailed(13),
noWirelessChannelAvailable(14),
dataPortConfigurationMismatch(15),
syslogDisabledWarning(16),
linkModeOptimizationMismatch(17),
managementPortStatus(18),
managementPortDisabledWarning(19),
tDDSynchronizationAlarm(20),
telecomsChannelBLoopback(21),
telecomsChannelALoopback(22),
telecomsChannelBStatus(23),
ethernetBridgingStatus(26),
secureMode(27),
syslogClientDisabledWarning(28),
managementPortConfigurationMismatch(29),
syslogLocalWrapped(30),
syslogLocalNearlyFull(31)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls which individual diagnostic alarms are enabled.
The unit may be configured to generate SNMP traps and/or
SMTP email alerts for these enabled alarms by selecting
'Enabled Diagnostic Alarms' on the 'SNMP Enabled Traps'
and/or 'SMTP Enabled Messages' attributes"
::= { snmpControl 7 }
sNMPSendAllTrapsAtStartup OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether or not all the enabled traps and alarms
(including cleared alarms) are reported at start-up."
::= { snmpControl 8 }
-- SNMPTrapTable group attribute definitions
--
sNMPTrapTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SNMP trap value, used to index the SNMPTrapTable."
::= { sNMPTrapTableEntry 1 }
sNMPTrapIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address to which all SNMP Traps are sent. NB: A
system reboot is required to activate changes to this
attribute."
::= { sNMPTrapTableEntry 2 }
sNMPTrapPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination port for SNMP Traps (default=162). NB: A
system reboot is required to activate changes to this
attribute."
::= { sNMPTrapTableEntry 3 }
sNMPTrapInternetAddressType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
ipv4(1),
ipv6(2),
ipv4z(3),
ipv6z(4),
unknown6(5),
unknown7(6),
unknown8(7),
unknown9(8),
unknown10(9),
unknown11(10),
unknown12(11),
unknown13(12),
unknown14(13),
unknown15(14),
unknown16(15),
dns(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Internet address specified by the associated
sNMPTrapInternetAddress."
::= { sNMPTrapTableEntry 4 }
sNMPTrapInternetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Internet address to which all SNMP Traps are sent."
::= { sNMPTrapTableEntry 5 }
sNMPTrapReceiverEnabled OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A value of 0 disables the sending of SNMP trap to
corresponding receiver. A value of 1 enables the sending
of SNMP trap to corresponding receiver."
::= { sNMPTrapTableEntry 6 }
-- Sntp group attribute definitions
--
sNTPState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SNTP control state"
::= { sntp 1 }
sNTPPollInterval OBJECT-TYPE
SYNTAX INTEGER (60..43200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SNTP server polling interval"
::= { sntp 4 }
sNTPSync OBJECT-TYPE
SYNTAX INTEGER {
noSync(0),
inSync(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If SNTP Sync fails then check the server settings in the
Remote Management page, or disable SNTP"
::= { sntp 5 }
sNTPLastSync OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last SNTP sync time"
::= { sntp 6 }
systemClock OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System clock presented as local time"
::= { sntp 7 }
timeZone OBJECT-TYPE
SYNTAX INTEGER {
gmtMinus1200(0),
gmtMinus1130(1),
gmtMinus1100(2),
gmtMinus1030(3),
gmtMinus1000(4),
gmtMinus0930(5),
gmtMinus0900(6),
gmtMinus0830(7),
gmtMinus0800(8),
gmtMinus0730(9),
gmtMinus0700(10),
gmtMinus0630(11),
gmtMinus0600(12),
gmtMinus0530(13),
gmtMinus0500(14),
gmtMinus0430(15),
gmtMinus0400(16),
gmtMinus0330(17),
gmtMinus0300(18),
gmtMinus0230(19),
gmtMinus0200(20),
gmtMinus0130(21),
gmtMinus0100(22),
gmtMinus0030(23),
gmtZero(24),
gmtPlus0030(25),
gmtPlus0100(26),
gmtPlus0130(27),
gmtPlus0200(28),
gmtPlus0230(29),
gmtPlus0300(30),
gmtPlus0330(31),
gmtPlus0400(32),
gmtPlus0430(33),
gmtPlus0500(34),
gmtPlus0530(35),
gmtPlus0600(36),
gmtPlus0630(37),
gmtPlus0700(38),
gmtPlus0730(39),
gmtPlus0800(40),
gmtPlus0830(41),
gmtPlus0900(42),
gmtPlus0930(43),
gmtPlus1000(44),
gmtPlus1030(45),
gmtPlus1100(46),
gmtPlus1130(47),
gmtPlus1200(48),
gmtPlus1230(49),
gmtPlus1300(50)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time zone offsets from Greenwich Mean Time (GMT)"
::= { sntp 8 }
daylightSaving OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Daylight Saving Time"
::= { sntp 9 }
sNTPPrimaryServer OBJECT-TYPE
SYNTAX INTEGER {
server1(0),
server2(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the primary SNTP server, determining the order
in which the servers are tried."
::= { sntp 10 }
sNTPPrimaryServerDeadTime OBJECT-TYPE
SYNTAX INTEGER (0..86400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time (in seconds) to wait before retrying communications
with an unresponsive primary SNTP server. Setting the
value to 0 disables the timer."
::= { sntp 11 }
sNTPServerRetries OBJECT-TYPE
SYNTAX INTEGER (0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of times the PTP will retry after an SNTP server
fails to respond."
::= { sntp 12 }
sNTPServerTimeout OBJECT-TYPE
SYNTAX INTEGER (1..15)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time (in seconds) the PTP will wait for a response from
an SNTP server."
::= { sntp 13 }
sNTPServerTableNumber OBJECT-TYPE
SYNTAX INTEGER (2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the SNTPServerTable."
::= { sntp 14 }
-- SNTPServerTable group attribute definitions
--
sNTPServerTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index range for the SNTPServerTable."
::= { sNTPServerTableEntry 1 }
sNTPServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of a valid SNTP server"
::= { sNTPServerTableEntry 2 }
sNTPServerPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP port number of the SNTP server. Defaults to port
123."
::= { sNTPServerTableEntry 3 }
sNTPServerStatus OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status message reflecting the result of communications
with the SNTP server when last polled"
::= { sNTPServerTableEntry 4 }
sNTPServerInternetAddressType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
ipv4(1),
ipv6(2),
ipv4z(3),
ipv6z(4),
unknown6(5),
unknown7(6),
unknown8(7),
unknown9(8),
unknown10(9),
unknown11(10),
unknown12(11),
unknown13(12),
unknown14(13),
unknown15(14),
unknown16(15),
dns(16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Internet address specified by the associated
sNTPServerInternetAddress."
::= { sNTPServerTableEntry 5 }
sNTPServerInternetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Internet address of a valid SNTP server"
::= { sNTPServerTableEntry 6 }
-- Reset group attribute definitions
--
systemReset OBJECT-TYPE
SYNTAX INTEGER {
running(0),
consoleReboot(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to '1' will cause a system
reboot. NB: a system reboot will apply any pending new
settings held in memory"
::= { reset 1 }
-- Versions group attribute definitions
--
softwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current software version"
::= { versions 1 }
hardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hardware platform version"
::= { versions 2 }
secondarySoftwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Secondary software version, used when the primary
software image is invalid or erased"
::= { versions 3 }
bootVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Boot code software version"
::= { versions 4 }
-- PubStats group attribute definitions
--
receiveDataRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average data rate over the last one second interval
(kbps)"
::= { pubStats 1 }
transmitDataRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average data rate over the last one second interval
(kbps)"
::= { pubStats 2 }
aggregateDataRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average data rate over the last one second interval
(kbps)"
::= { pubStats 3 }
wirelessLinkAvailability OBJECT-TYPE
SYNTAX INTEGER (0..1000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link availability calculated since the last reset of the
system counters, as a percentage multiplied by 10000 to
give four decimal places of precision"
::= { pubStats 4 }
wirelessLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
up(0),
registering(1),
searching(2),
acquiring(3),
radarCAC(4),
initialising(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current status of the wireless link"
::= { pubStats 5 }
byteErrorRatio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reciprocal of the byte error ratio calculated since the
last reset of the system counters"
::= { pubStats 6 }
receiveModulationModeDetail OBJECT-TYPE
SYNTAX INTEGER {
runningAtMaximumReceiveMode(0),
runningAtUserConfiguredMaxModulationMode(1),
restrictedBecauseInstallationIsArmed(2),
restrictedBecauseOfByteErrorsOnTheWirelessLink(3),
restrictedBecauseTheLinkParametersAreUpdating(4),
restrictedBecauseChannelChangeIsInProgress(5),
restrictedDueToTheLowEthernetLinkSpeed(6),
runningAtMaximumReceiveModeForChannelBandwidth(7),
limitedByTheWirelessConditions(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The reason for the current receive modulation mode"
::= { pubStats 7 }
ethernetBridgingAvailability OBJECT-TYPE
SYNTAX INTEGER (0..1000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link availability bridging Ethernet traffic calculated
since the last reset of the system counters, as a
percentage multiplied by 10000 to give four decimal
places of precision"
::= { pubStats 8 }
-- Encryption group attribute definitions
--
encryptionAlgorithm OBJECT-TYPE
SYNTAX INTEGER {
none(0),
aESRijndael(1),
aES256bitRijndael(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Encryption Algorithm used by the wireless link. NB:
A system reboot is required to activate changes to this
attribute. NB: The same Encryption Algorithm must be
configured at BOTH ends of the link for it to function
correctly"
::= { encryption 1 }
-- TDDControl group attribute definitions
--
tDDSynchronizationMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TDD Synchronization Mode selection"
::= { tDDControl 1 }
-- AAAControl group attribute definitions
--
userTableNumber OBJECT-TYPE
SYNTAX INTEGER (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of entries in the userTable"
::= { aAAControl 1 }
-- UserTable group attribute definitions
--
userTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..10)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"used to index values in the userTable."
::= { userTableEntry 1 }
userName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"User name which must be entered, along with the
appropriate password, in order to gain access to the
system."
::= { userTableEntry 2 }
userRole OBJECT-TYPE
SYNTAX INTEGER {
readOnly(0),
systemAdministrator(1),
securityOfficer(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Role of the selected user. A Security Officer has access
to and can modify all settings. A System Administrator
has access to and can modify all non-security settings. A
Read Only user can view settings, but cannot make any
changes."
::= { userTableEntry 3 }
userEnabled OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enable / Disable the selected user"
::= { userTableEntry 4 }
userPassword OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User password, which must be entered in order to gain
access to the system."
::= { userTableEntry 5 }
-- SyslogControl group attribute definitions
--
syslogClient OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enable or disable the syslog client"
::= { syslogControl 1 }
syslogState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The syslog service has been enabled or disabled"
::= { syslogControl 2 }
-- Supplementary group attribute definitions
--
longitude OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..19))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The longitude of the unit, measured in decimal degrees.
This object is set by the SNMP manager and has no
internal function."
::= { supplementary 1 }
latitude OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..19))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The latitude of the unit, measured in decimal degrees.
This object is set by the SNMP manager and has no
internal function."
::= { supplementary 2 }
altitude OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The altitude of the unit, measured in metres. This
object is set by the SNMP manager and has no internal
function."
::= { supplementary 3 }
-- Enterprise NOTIFICATION definitions
--
channelChangeTrap NOTIFICATION-TYPE
OBJECTS { receiveChannel }
STATUS current
DESCRIPTION "The PTP radio has changed wireless channel.
This has been caused by either
i) mandatory radar avoidance,
a DFS impulsive interference event will also be
detected,
or
ii) Dynamic Spectrum Optimization, (DSO)
DSO improves link performance by selecting the
most appropriate transmit and receive channels
with the lowest level of interference."
::= { ptpTrapPrefix 1 }
dfsImpulsiveInterferenceTrap NOTIFICATION-TYPE
OBJECTS { receiveChannel }
STATUS current
DESCRIPTION "DFS impulsive interference detected event"
::= { ptpTrapPrefix 2 }
dataPortStatusTrap NOTIFICATION-TYPE
OBJECTS { dataPortStatus }
STATUS current
DESCRIPTION
"Current status of the Ethernet link. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 3 }
telecomsChannelAStatusTrap NOTIFICATION-TYPE
OBJECTS { telecomsChannelAStatus }
STATUS current
DESCRIPTION
"Current status of telecoms channel A. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 4 }
telecomsChannelBStatusTrap NOTIFICATION-TYPE
OBJECTS { telecomsChannelBStatus }
STATUS current
DESCRIPTION
"Current status of telecoms channel B. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 5 }
channelALoopbackTrap NOTIFICATION-TYPE
OBJECTS { channelALoopback }
STATUS current
DESCRIPTION
"The loopback status of telecoms channel A. This is
intended for installation testing and should be set to
'None' for normal operation. The wire connections to a
unit can be tested by applying a 'Copper' loopback to the
local unit. The wireless connection to the remote unit
can be tested by applying a 'Wireless' loopback to the
remote unit with no loopback on the local unit. NB: a
change of state may generate an SNMP trap and/or SMTP
email alert"
::= { ptpTrapPrefix 6 }
channelBLoopbackTrap NOTIFICATION-TYPE
OBJECTS { channelBLoopback }
STATUS current
DESCRIPTION
"The loopback status of telecoms channel B. This is
intended for installation testing and should be set to
'None' for normal operation. The wire connections to a
unit can be tested by applying a 'Copper' loopback to the
local unit. The wireless connection to the remote unit
can be tested by applying a 'Wireless' loopback to the
remote unit with no loopback on the local unit. NB: a
change of state may generate an SNMP trap and/or SMTP
email alert"
::= { ptpTrapPrefix 7 }
regionCodeTrap NOTIFICATION-TYPE
OBJECTS { regionCode }
STATUS current
DESCRIPTION
"The region code prohibits the wireless unit from
operating outside the regulated limits. An invalid region
code indicates a corrupted license key. NB: a change of
state may generate an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 8 }
installStatusTrap NOTIFICATION-TYPE
OBJECTS { installStatus }
STATUS current
DESCRIPTION
"A non-zero value indicates that signalling was received
with the wrong MAC address or a mismatched link name. NB:
It is very unusual to detect this, because units with
mis-configured Target MAC Address will normally fail to
establish a wireless link. However, rare circumstances
may establish a partial wireless link and detect this
situation. NB: A non-zero value on start-up, or a change
of value during operation, may generate an SNMP trap
and/or SMTP email alert"
::= { ptpTrapPrefix 9 }
installArmStateTrap NOTIFICATION-TYPE
OBJECTS { installArmState }
STATUS current
DESCRIPTION
"Indicates if the unit is being installed. NB: a change
of state may generate an SNMP trap and/or SMTP email
alert"
::= { ptpTrapPrefix 10 }
unitOutOfCalibrationTrap NOTIFICATION-TYPE
OBJECTS { unitOutOfCalibration }
STATUS current
DESCRIPTION
"The unit is out of calibration"
::= { ptpTrapPrefix 11 }
incompatibleRegionCodesTrap NOTIFICATION-TYPE
OBJECTS { incompatibleRegionCodes }
STATUS current
DESCRIPTION
"The master and slave units have incompatible region
codes. NB: Both units must have compatible license keys"
::= { ptpTrapPrefix 14 }
noWirelessChannelAvailableTrap NOTIFICATION-TYPE
OBJECTS { noWirelessChannelAvailable }
STATUS current
DESCRIPTION
"Spectrum Management was unable to locate a suitable
wireless channel to operate on"
::= { ptpTrapPrefix 15 }
wirelessLinkDisabledWarningTrap NOTIFICATION-TYPE
OBJECTS { wirelessLinkDisabledWarning }
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the wireless interface has
disabled wireless traffic"
::= { ptpTrapPrefix 16 }
dataPortDisabledWarningTrap NOTIFICATION-TYPE
OBJECTS { dataPortDisabledWarning }
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the Ethernet interface has
disabled Ethernet traffic"
::= { ptpTrapPrefix 17 }
dataPortFiberStatusTrap NOTIFICATION-TYPE
OBJECTS { dataPortFiberStatus }
STATUS current
DESCRIPTION
"If the fiber link is not OK, there are three possible
causes: Either the fiber link has been installed but
disabled (because the license key does not include fiber
support), the link could not be established even though
no LOS was detected (i.e. an optical carrier was
detected, which could be due to a broken TX fiber, or
because the link is disabled at the fiber link partner),
or the link could not be established and LOS is detected
(i.e. no optical carrier is detected). NB: a change of
status may generate an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 18 }
dataPortConfigurationMismatchTrap NOTIFICATION-TYPE
OBJECTS { dataPortConfigurationMismatch }
STATUS current
DESCRIPTION
"The detection of Ethernet fragments (runt packets) when
the link is in full duplex is an indication of an
auto-negotiation or forced configuration mismatch"
::= { ptpTrapPrefix 19 }
incompatibleMasterAndSlaveTrap NOTIFICATION-TYPE
OBJECTS { incompatibleMasterAndSlave }
STATUS current
DESCRIPTION
"A non-zero value indicates that the master and slave
ends of a link are different hardware products, or have
different software versions. NB: It is very unusual to
detect this, because incompatible units will normally
fail to establish a wireless link. However, some
combinations may establish a partial wireless link and
detect this situation. NB: A non-zero value may generate
an SNMP trap and/or SMTP email alert"
::= { ptpTrapPrefix 20 }
sNTPSyncTrap NOTIFICATION-TYPE
OBJECTS { sNTPSync }
STATUS current
DESCRIPTION
"If SNTP Sync fails then check the server settings in the
Remote Management page, or disable SNTP"
::= { ptpTrapPrefix 21 }
tDDSynchronizationAlarmTrap NOTIFICATION-TYPE
OBJECTS { tDDSynchronizationAlarm }
STATUS current
DESCRIPTION
"Not Synchronized indicates failure of the external
timing system for a period greater than the holdover
timer. TDD frame timing will have drifted, and this link
may cause interference with other links in a synchronized
network. Timing System Failure is an early warning,
indicating that 80% of the holdover period has expired."
::= { ptpTrapPrefix 22 }
managementPortStatusTrap NOTIFICATION-TYPE
OBJECTS { managementPortStatus }
STATUS current
DESCRIPTION
"Current status of the out-of-band management link. NB: a
change of state may generate an SNMP trap and/or SMTP
email alert"
::= { ptpTrapPrefix 23 }
managementPortDisabledWarningTrap NOTIFICATION-TYPE
OBJECTS { managementPortDisabledWarning }
STATUS current
DESCRIPTION
"The SNMP ifAdminStatus of the out-of-band management
interface has disabled Ethernet traffic"
::= { ptpTrapPrefix 24 }
linkModeOptimizationMismatchTrap NOTIFICATION-TYPE
OBJECTS { linkModeOptimizationMismatch }
STATUS current
DESCRIPTION
"The remote node of this link has been configured with a
different link mode optimization"
::= { ptpTrapPrefix 25 }
managementPortConfigurationMismatchTrap NOTIFICATION-TYPE
OBJECTS { managementPortConfigurationMismatch }
STATUS current
DESCRIPTION
"The detection of Ethernet fragments (runt packets) when
the link is in full duplex is an indication of an
auto-negotiation or forced configuration mismatch. This
alarm is only raised if an Out-of-Band Management Mode
has been configured."
::= { ptpTrapPrefix 28 }
syslogStateTrap NOTIFICATION-TYPE
OBJECTS { syslogState }
STATUS current
DESCRIPTION
"The syslog service has been enabled or disabled"
::= { ptpTrapPrefix 30 }
syslogLocalNearlyFullTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION "The syslog local log is nearly full (90%)"
::= { ptpTrapPrefix 31 }
syslogLocalWrappedTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION "The syslog local log has wrapped"
::= { ptpTrapPrefix 32 }
syslogClientTrap NOTIFICATION-TYPE
OBJECTS { syslogClient }
STATUS current
DESCRIPTION
"Enable or disable the syslog client"
::= { ptpTrapPrefix 33 }
secureModeAlarmTrap NOTIFICATION-TYPE
OBJECTS { secureModeAlarm }
STATUS current
DESCRIPTION
"The secure mode (e.g. FIPS, UC-APL) state of the unit.
The secure mode is not configured(1) state indicates that
the unit is capable of secure mode operation, and one or
more of the following security materials has not been
configured: Key Of Keys, Private Key, Public Certificate,
DRNG Entropy Status, Wireless Encryption Key. The secure
mode mode is configured but not active(2) state indicates
that the unit is capable of secure mode operation, and
the security material has been configured, but the
configuration of interfaces is not consistent with secure
mode operation. The secure mode is not supported(3) state
indicates that the unit is not capable of secure mode
operation. The secure mode capability requires
appropriate hardware compatibility, license key and
software image."
::= { ptpTrapPrefix 34 }
ethernetBridgingStatusAlarmTrap NOTIFICATION-TYPE
OBJECTS { ethernetBridgingStatusAlarm }
STATUS current
DESCRIPTION
"Ethernet traffic bridging is disabled because the
wireless link is not operating at the configured Lowest
Ethernet Modulation Mode"
::= { ptpTrapPrefix 35 }
END