mibs/MIBS/ciena/CIENA-CES-NOTIFICATIONS-CONTROL-MIB
2023-12-05 12:25:34 +01:00

825 lines
31 KiB
Plaintext

-- This file was included in Ciena MIB release MIBS-CIENA-CES-08-07-00-024
--
-- CIENA-CES-NOTIFICATIONS-CONTROL-MIB.my
--
--
CIENA-CES-NOTIFICATIONS-CONTROL DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY
FROM SNMPv2-SMI
cienaCesNotificationsControlModule
FROM CIENA-SMI
CienaGlobalState
FROM CIENA-TC;
cienaCesNotificationsControlMIB MODULE-IDENTITY
LAST-UPDATED "201706070000Z"
ORGANIZATION "Ciena Corp."
CONTACT-INFO
" Mib Meister
7035 Ridge Road
Hanover, Maryland 21076
USA
Phone: +1 800 921 1144
Email: support@ciena.com"
DESCRIPTION
"This module defines the object identifiers to control the notification state for
each of the notification or set of notifications defined for CES."
REVISION
"201706070000Z"
DESCRIPTION
"Updated contact info."
REVISION
"201610270000Z"
DESCRIPTION
"Added cienaCesCommandFileCompletedTrapState and
cienaCesCommandFileFailedTrapState."
REVISION
"201610070000Z"
DESCRIPTION
"Added cienaCesXcvrUncertifiedTrapState at cienaCesNotificationsControl 73."
REVISION
"201603060000Z"
DESCRIPTION
"Added cienaCesDataplanePortShapingSubscriptionTrapState at cienaCesNotificationsControl 72."
REVISION
"201505060000Z"
DESCRIPTION
"Added cienaCesAlarmCutoffTrapState at cienaCesNotificationsControl 71."
REVISION
"201501070000Z"
DESCRIPTION
"Added cienaCesSyncModuleSlotTrapState at cienaCesNotificationsControl 70."
REVISION
"201412100000Z"
DESCRIPTION
"Added cienaCesSyncInputProtectionUnitTrapState at cienaCesNotificationsControl 68.
Added cienaCesSyncInputProtectionGroupTrapState at cienaCesNotificationsControl 69."
REVISION
"201402250000Z"
DESCRIPTION
"Added cienaCesChassisUsbFlashEnableChangeTrapState at cienaCesNotificationsControl 66.
Added cienaCesChassisAirFilterTrapState at cienaCesNotificationsControl 67."
REVISION
"201312180000Z"
DESCRIPTION
"Added cienaCesIOMStateChangeTrapState at cienaCesNotificationsControl 61.
Added cienaCesIOMBuzzerEnableChangeTrapState at cienaCesNotificationsControl 62.
Added cienaCesIOMBuzzerStateChangeTrapState at cienaCesNotificationsControl 63.
Added cienaCesIOMAlarmOutputStateChangeTrapState at cienaCesNotificationsControl 64.
Added cienaCesIOMAlarmInputStateChangeTrapState at cienaCesNotificationsControl 65."
REVISION
"201311050000Z"
DESCRIPTION
"Added cienaCesCfmDelayVariationFaultTrapState."
REVISION
"201310280000Z"
DESCRIPTION
"Added cienaCesCfmSyntheticLossNearFaultTrapState and cienaCesCfmSyntheticLossFarFaultTrapState
for controlling synthetic loss traps"
REVISION
"201103220000Z"
DESCRIPTION
"Initial creation. This module defines the object identifiers to control
the notification state for each of the notification or set of notifications
defined for CES."
::= { cienaCesNotificationsControlModule 1 }
cienaCesNotificationsControl OBJECT IDENTIFIER ::= { cienaCesNotificationsControlMIB 1 }
--
-- Node definitions
--
--
-- Port related notification control
--
cienaCesPortEnhancedLinkTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the device generates enhanced port link up
and down traps."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 1 }
cienaCesPortStdLinkTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the device generates standard port link up
and down traps."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 2 }
cienaCesPortAllTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the device generates any port related traps."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 3 }
--
-- Equipment related notification control
--
cienaCesModuleAllModulesTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the device sends out module related traps."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 6 }
cienaCesModuleAllModulesHealthTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the device sends out module health related traps."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 7 }
cienaCesModuleSensorTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether device sends out module sensor related traps."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 8 }
cienaCesModuleHATrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the device sends out the HA switchover trap."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 9 }
cienaCesModuleProtectionModeTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the device sends out the protection mode
state change trap."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 10 }
cienaCesModulePOSTErrorTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the device sends out the POST error trap."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 11 }
cienaCesModuleSwitchFabricDisruptedTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the device sends out the switch fabric disrupted trap."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 12 }
cienaCesChassisAllPowerSupplyTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the device sends out power-supply
related traps."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 14 }
cienaCesChassisAllFanTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the device sends out chassis fan related traps."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 15 }
cienaCesChassisAllFanTrayTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the device sends out chassis fan tray related traps."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 16 }
cienaCesChassisAllFanTempTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the device sends out chassis fan temperature
related traps."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 17 }
cienaCesChassisHealthTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the device sends out chassis health related
traps."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 18 }
--
-- RAPS
--
cienaCesRapsAlarmTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the device sends out RAPS alarm related
traps."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 19 }
--
-- MPLS
--
cienaCesMplsTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
MPLS related traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 20 }
--
-- CFM Fault trap control
--
cienaCesCfmFaultTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
CFM fault traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 21 }
cienaCesCfmDelayFaultTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
CFM Y.1731 delay measurement traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 22 }
cienaCesCfmJitterFaultTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
CFM Y.1731 jitter measurement traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 23 }
cienaCesCfmFrameLossNearFaultTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
CFM Y.1731 frame-loss-near measurement traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 24 }
cienaCesCfmFrameLossFarFaultTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
CFM Y.1731 frame-loss-far measurement traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 25 }
cienaCesCfmSyntheticLossNearFaultTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
CFM Y.1731 synthetic-loss near fault and clear traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 26 }
cienaCesCfmSyntheticLossFarFaultTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
CFM Y.1731 synthetic-loss far fault and clear traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 27 }
cienaCesPbtFaultTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
PBB-TE related traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 28 }
--
-- BFD Fault trap control knob
--
cienaCesBfdTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
BFD related traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 29 }
--IP Interface
cienaCesIPMgmtInterfaceAddrChangeTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes the
IP address change trap to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 31 }
cienaCesIPMgmtInterfaceGatewayAddrChangeTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes the
IP Gateway change trap to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 32 }
--Dataplane
cienaCesDataplaneUcastTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
dataplane unicast threshold exceed/normal traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 35 }
cienaCesDataplaneBcastTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
dataplane broadcast threshold exceed/normal traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 36 }
cienaCesDataplaneMcastTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' will cause
dataplane multicast threshold exceed/normal traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 37 }
cienaCesPortXcvrLinkStateChangeTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
port transceiver link state change traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 40 }
cienaCesPortXcvrErrorTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
port transceiver error traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 41 }
cienaCesPortXcvrTempChangeTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
port transceiver temperature change traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 42 }
cienaCesPortXcvrVoltageChangeTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
port transceiver voltage change traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 43 }
cienaCesPortXcvrBiasChangeTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
port transceiver bias change traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 44 }
cienaCesPortXcvrTxPowerChangeTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
port transceiver TX power change traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 45 }
cienaCesPortXcvrRxPowerChangeTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
port transceiver RX power change traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 46 }
cienaCesPortXcvrSpeedInfoTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
port transceiver speed information missing traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 47 }
cienaCesRstpPortBackupTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' cause
cienaCesRstpPortBackupNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 48 }
cienaCesRstpPortPvstBPduReceivedTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' cause
cienaCesRstpPvstBpduReceivedNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 49 }
cienaCesRstpPortSelfLoopTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesRstpSelfLoopNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 50 }
cienaCesRstpPortOperEdgeTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesRstpPortOperEdgeNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 51 }
cienaCesRstpPortFlapTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesRstpPortFlapNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 52 }
cienaCesRstpBridgeRootPortLostTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesRstpBridgeRootPortLostNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 53 }
cienaCesFeatureLicenseStatusTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesPremiumFeatureLicenseNotInstalledNotification and
cienaCesPremiumFeatureLicensePartialStatusNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 54 }
cienaCesFeatureLicenseInstallErrorTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesPremiumFeatureLicenseInstallErrorNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 55 }
cienaCesFileTransferCompletionTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesFTransferCompletion traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 56 }
cienaCesSwXgradeCompletionTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesSwXgradeCompletion traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 57 }
cienaCesSystemConfigImproperCmdTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesImproperCmdInConfigFile traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 58 }
cienaCesOamLinkEventTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesOamLinkEventTrap traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 59 }
--
-- CFM Fault trap control continued
--
cienaCesCfmDelayVariationFaultTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
CFM Y.1731 Delay Variation measurement traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 60 }
--
-- Chassis IOM trap control
--
cienaCesIOMStateChangeTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesChassisIOMStateChangeNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 61 }
cienaCesIOMBuzzerEnableChangeTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesChassisIOMBuzzerEnableChangeNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 62 }
cienaCesIOMBuzzerStateChangeTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesChassisIOMBuzzerStateChangeNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 63 }
cienaCesIOMAlarmOutputStateChangeTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesChassisIOMAlarmOutputStateChangeNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 64 }
cienaCesIOMAlarmInputStateChangeTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesChassisIOMAlarmInputStateChangeNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 65 }
--
-- USB Flash trap control
--
cienaCesChassisUsbFlashEnableChangeTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesChassisUsbEnabledNotification and
cienaCesChassisUsbDisabledNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 66 }
--
-- Air Filter trap control
--
cienaCesChassisAirFilterTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesChassisAirFilterServiceNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 67 }
--
-- Sync Input Protection Unit trap control
--
cienaCesSyncInputProtectionUnitTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesSyncInputPUStateChangeNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 68 }
--
-- Sync Input Protection Group trap control
--
cienaCesSyncInputProtectionGroupTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesSyncInputProtGroupStateChangeNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 69 }
--
-- Sync Module Slot trap control
--
cienaCesSyncModuleSlotTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesSyncModuleSlotStateChangeNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 70 }
--
-- Alarm Cutoff trap control
--
cienaCesChassisAlarmCutoffTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesChassisAlarmCutoffNotification traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 71 }
cienaCesDataplanePortShapingSubscriptionTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
dataplane cienaCesDpPortShapingSubscriptionExceedsOperSpeed and
cienaCesDpPortShapingSubscriptionWithinOperSpeed traps to be suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 72 }
cienaCesPortXcvrUncertifiedTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'enabled' enables generation of
cienaCesPortXcvrUncertifiedNotification traps."
DEFVAL { disabled }
::= { cienaCesNotificationsControl 73 }
--
-- Command File Complete trap control
--
cienaCesCommandFileCompletedTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesCommandFileCompletedNotification traps to be
suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 74 }
cienaCesCommandFileFailedTrapState OBJECT-TYPE
SYNTAX CienaGlobalState
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to 'disabled' causes
cienaCesCommandFileFailedNotification traps to be
suppressed."
DEFVAL { enabled }
::= { cienaCesNotificationsControl 75 }
END