-- CIENA-WS-NOTIFICATION-MIB.my
--
CIENA-WS-NOTIFICATION-MIB DEFINITIONS ::= BEGIN
IMPORTS
Unsigned32, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, OBJECT-IDENTITY
FROM SNMPv2-SMI
cienaWsNotifications
FROM CIENA-WS-MIB
TEXTUAL-CONVENTION
FROM SNMPv2-TC;
cienaWsNotificationMIB MODULE-IDENTITY
LAST-UPDATED "201801150000Z"
ORGANIZATION "Ciena Corporation"
CONTACT-INFO
"Web URL: http://www.ciena.com/
Postal: 7035 Ridge Road
Hanover, Maryland 21076
U.S.A.
Phone: +1 800-921-1144
Fax: +1 410-694-5750"
DESCRIPTION
"Notification definitions for Waveserver. Contains alarm notifications and link
state defects."
REVISION "201801150000Z"
DESCRIPTION "Updates wsAlarmNotificationActiveStatus from TruthValue to include
active(1), inactive(2), and intermittent(3) states"
REVISION "201611140000Z"
DESCRIPTION "Added MODULE-IDENTITY statements."
::= { cienaWsNotifications 3 }
-- Textual conventions
DisplayString32 ::= TEXTUAL-CONVENTION
DISPLAY-HINT "32t"
STATUS current
DESCRIPTION
"A UTF-8 string with a max length of 32 characters"
SYNTAX OCTET STRING(SIZE(1..32))
-- Alarm Notifications
wsAlarmNotification NOTIFICATION-TYPE
OBJECTS {
wsAlarmNotificationSiteId,
wsAlarmNotificationGroupId,
wsAlarmNotificationMemberId,
wsAlarmNotificationInstanceId,
wsAlarmNotificationDateAndTime,
wsAlarmNotificationTableId,
wsAlarmNotificationSeverity,
wsAlarmNotificationInstance,
wsAlarmNotificationDescription,
wsAlarmNotificationActiveStatus,
wsAlarmNotificationEntityType
}
STATUS current
DESCRIPTION
"Ciena Wavesever notification for an alarm raising or clearing"
::= { cienaWsNotifications 11 }
wsAlarmNotificationSiteId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system Site ID."
::= { wsAlarmNotification 1 }
wsAlarmNotificationGroupId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system Group ID."
::= { wsAlarmNotification 2 }
wsAlarmNotificationMemberId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system Member ID."
::= { wsAlarmNotification 3 }
wsAlarmNotificationInstanceId OBJECT-TYPE
SYNTAX Unsigned32(1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm Instance ID."
::= { wsAlarmNotification 4 }
wsAlarmNotificationDateAndTime OBJECT-TYPE
SYNTAX DisplayString32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The local date and time when alarm was raised."
::= { wsAlarmNotification 5 }
wsAlarmNotificationTableId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm table ID."
::= { wsAlarmNotification 6 }
wsAlarmNotificationSeverity OBJECT-TYPE
SYNTAX INTEGER {
cleared(1),
critical(3),
major(4),
minor(5),
warning(6),
info(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm severity."
::= { wsAlarmNotification 7 }
wsAlarmNotificationInstance OBJECT-TYPE
SYNTAX DisplayString32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object instance the alarm is raised against."
::= { wsAlarmNotification 8 }
wsAlarmNotificationDescription OBJECT-TYPE
SYNTAX DisplayString32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm description."
::= { wsAlarmNotification 9 }
wsAlarmNotificationActiveStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
inactive(2),
intermittent(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm active status."
::= { wsAlarmNotification 10 }
-- Port Type
wsAlarmNotificationEntityType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(0),
other(1),
clientPort(2),
linePort(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm source entity type if applicable."
::= { wsAlarmNotification 11 }
-- Link state notifications
-- The following notification communicates the state of a link. This includes
-- detailed information about the current health of the link.
wsLinkStateAlarmNotification NOTIFICATION-TYPE
OBJECTS {
wsLinkStateAlarmNotificationSiteId,
wsLinkStateAlarmNotificationGroupId,
wsLinkStateAlarmNotificationMemberId,
wsLinkStateAlarmNotificationInstanceId,
wsLinkStateAlarmNotificationDateAndTime,
wsLinkStateAlarmNotificationSeverity,
wsLinkStateAlarmNotificationInstance,
wsLinkStateAlarmNotificationDescription,
wsLinkStateAlarmNotificationPtpRxLos,
wsLinkStateAlarmNotificationPtpRxLol,
wsLinkStateAlarmNotificationPtpTxLos,
wsLinkStateAlarmNotificationPtpTxLol,
wsLinkStateAlarmNotificationEthFecLossSync,
wsLinkStateAlarmNotificationEthEBer,
wsLinkStateAlarmNotificationEthRsLf,
wsLinkStateAlarmNotificationEthRsRf,
wsLinkStateAlarmNotificationEthPcsLobl,
wsLinkStateAlarmNotificationEthPcsLoam,
wsLinkStateAlarmNotificationEthPcsLol,
wsLinkStateAlarmNotificationEthRsLinkDown,
wsLinkStateAlarmNotificationOtuLoc,
wsLinkStateAlarmNotificationOtuFreqOor,
wsLinkStateAlarmNotificationOtuLof,
wsLinkStateAlarmNotificationOtuPreFecSf,
wsLinkStateAlarmNotificationOtuPreFecSd,
wsLinkStateAlarmNotificationOtuLom,
wsLinkStateAlarmNotificationOtuBdi,
wsLinkStateAlarmNotificationOtuTtiMismatch,
wsLinkStateAlarmNotificationOduOci,
wsLinkStateAlarmNotificationOduAis,
wsLinkStateAlarmNotificationOduLck,
wsLinkStateAlarmNotificationOduSf,
wsLinkStateAlarmNotificationOduSd,
wsLinkStateAlarmNotificationOduTtiMismatch,
wsLinkStateAlarmNotificationOduBdi,
wsLinkStateAlarmNotificationOduPtiMismatch,
wsLinkStateAlarmNotificationOduFeClientSf,
wsLinkStateAlarmNotificationOduSkewOor,
wsLinkStateAlarmNotificationEntityType
}
STATUS current
DESCRIPTION
"Ciena Waveserver notification for line faults."
::= { cienaWsNotifications 12 }
wsLinkStateAlarmNotificationSiteId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The line fault site ID."
::= { wsLinkStateAlarmNotification 1 }
wsLinkStateAlarmNotificationGroupId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system Group ID."
::= { wsLinkStateAlarmNotification 2 }
wsLinkStateAlarmNotificationMemberId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The system Member ID."
::= { wsLinkStateAlarmNotification 3 }
wsLinkStateAlarmNotificationInstanceId OBJECT-TYPE
SYNTAX Unsigned32(1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The line fault instance ID."
::= { wsLinkStateAlarmNotification 4 }
wsLinkStateAlarmNotificationDateAndTime OBJECT-TYPE
SYNTAX DisplayString32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The local date and time when alarm was raised."
::= { wsLinkStateAlarmNotification 5 }
wsLinkStateAlarmNotificationSeverity OBJECT-TYPE
SYNTAX INTEGER {
cleared(1),
critical(3),
major(4),
minor(5),
warning(6),
info(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm severity."
::= { wsLinkStateAlarmNotification 7 }
wsLinkStateAlarmNotificationInstance OBJECT-TYPE
SYNTAX DisplayString32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object instance the alarm is raised against."
::= { wsLinkStateAlarmNotification 8 }
wsLinkStateAlarmNotificationDescription OBJECT-TYPE
SYNTAX DisplayString32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm description."
::= { wsLinkStateAlarmNotification 9 }
-- PTP
wsLinkStateAlarmNotificationPtpDefects OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Defects related to the physical termination point."
::= { wsLinkStateAlarmNotification 10 }
wsLinkStateAlarmNotificationPtpRxLos OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP alarms for the link."
::= { wsLinkStateAlarmNotificationPtpDefects 1 }
wsLinkStateAlarmNotificationPtpRxLol OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP alarms for the link."
::= { wsLinkStateAlarmNotificationPtpDefects 2 }
wsLinkStateAlarmNotificationPtpTxLos OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP alarms for the link."
::= { wsLinkStateAlarmNotificationPtpDefects 3 }
wsLinkStateAlarmNotificationPtpTxLol OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PTP alarms for the link."
::= { wsLinkStateAlarmNotificationPtpDefects 4 }
-- Ethernet alarms
wsLinkStateAlarmNotificationEthDefects OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Ethernet defects."
::= { wsLinkStateAlarmNotification 11 }
wsLinkStateAlarmNotificationEthPcsHighBer OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ethernet PCS high bit error rate."
::= { wsLinkStateAlarmNotificationEthDefects 1 }
wsLinkStateAlarmNotificationEthPcsLoam OBJECT-TYPE
SYNTAX INTEGER { inactive(0), active(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ethernet PCS loss of alignment marker."
::= { wsLinkStateAlarmNotificationEthDefects 2 }
wsLinkStateAlarmNotificationEthPcsLobl OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ethernet PCS loss of block lock."
::= { wsLinkStateAlarmNotificationEthDefects 3 }
wsLinkStateAlarmNotificationEthRsLinkDown OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ethernet RS link down."
::= { wsLinkStateAlarmNotificationEthDefects 4 }
wsLinkStateAlarmNotificationEthRsLf OBJECT-TYPE
SYNTAX INTEGER { inactive(0), active(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ethernet RS local fault."
::= { wsLinkStateAlarmNotificationEthDefects 5 }
wsLinkStateAlarmNotificationEthRsRf OBJECT-TYPE
SYNTAX INTEGER { inactive(0), active(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ethernet RS remote fault."
::= { wsLinkStateAlarmNotificationEthDefects 6 }
wsLinkStateAlarmNotificationEthFecLossSync OBJECT-TYPE
SYNTAX INTEGER { inactive(0), active(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ethernet FEC loss of alignment marker."
::= { wsLinkStateAlarmNotificationEthDefects 7 }
wsLinkStateAlarmNotificationEthPmaSool OBJECT-TYPE
SYNTAX INTEGER { inactive(0), active(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ethernet PMA serdes out of lock."
::= { wsLinkStateAlarmNotificationEthDefects 8 }
-- OTU Alarms
wsLinkStateAlarmNotificationOtuDefects OBJECT-IDENTITY
STATUS current
DESCRIPTION
"OTU layer defects."
::= { wsLinkStateAlarmNotification 12 }
wsLinkStateAlarmNotificationOtuLoc OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU loss of clock."
::= { wsLinkStateAlarmNotificationOtuDefects 1}
wsLinkStateAlarmNotificationOtuFreqOor OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU frequency out of range."
::= { wsLinkStateAlarmNotificationOtuDefects 2 }
wsLinkStateAlarmNotificationOtuLof OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU loss of frame."
::= { wsLinkStateAlarmNotificationOtuDefects 3 }
wsLinkStateAlarmNotificationOtuPreFecSf OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU pre-FEC signal fail."
::= { wsLinkStateAlarmNotificationOtuDefects 4 }
wsLinkStateAlarmNotificationOtuPreFecSd OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU pre-FEC signal degrade."
::= { wsLinkStateAlarmNotificationOtuDefects 5 }
wsLinkStateAlarmNotificationOtuLom OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU loss of multi-frame."
::= { wsLinkStateAlarmNotificationOtuDefects 6 }
wsLinkStateAlarmNotificationOtuBdi OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU backwards defect indicator."
::= { wsLinkStateAlarmNotificationOtuDefects 7 }
wsLinkStateAlarmNotificationOtuTtiMismatch OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTU TTI mismatch."
::= { wsLinkStateAlarmNotificationOtuDefects 8 }
-- ODU
wsLinkStateAlarmNotificationOduDefects OBJECT-IDENTITY
STATUS current
DESCRIPTION
"ODU layer defects."
::= { wsLinkStateAlarmNotification 13 }
wsLinkStateAlarmNotificationOduOci OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU open connection indication."
::= { wsLinkStateAlarmNotificationOduDefects 1 }
wsLinkStateAlarmNotificationOduAis OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU alarm indicating signal."
::= { wsLinkStateAlarmNotificationOduDefects 2 }
wsLinkStateAlarmNotificationOduLck OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU locked."
::= { wsLinkStateAlarmNotificationOduDefects 3 }
wsLinkStateAlarmNotificationOduSf OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU signal fail."
::= { wsLinkStateAlarmNotificationOduDefects 4 }
wsLinkStateAlarmNotificationOduSd OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU signal degrade."
::= { wsLinkStateAlarmNotificationOduDefects 5 }
wsLinkStateAlarmNotificationOduTtiMismatch OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU TTI mismatch."
::= { wsLinkStateAlarmNotificationOduDefects 6 }
wsLinkStateAlarmNotificationOduBdi OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU backwards defect indicator."
::= { wsLinkStateAlarmNotificationOduDefects 7 }
wsLinkStateAlarmNotificationOduPtiMismatch OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU payload type indicator mismatch."
::= { wsLinkStateAlarmNotificationOduDefects 8 }
wsLinkStateAlarmNotificationOduFeClientSf OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU far-end client signal fail."
::= { wsLinkStateAlarmNotificationOduDefects 9 }
wsLinkStateAlarmNotificationOduSkewOor OBJECT-TYPE
SYNTAX INTEGER {
inactive(0),
active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ODU skew out of range."
::= { wsLinkStateAlarmNotificationOduDefects 10 }
wsLinkStateAlarmNotificationEntityType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(0),
other(1),
clientPort(2),
linePort(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm source entity type if applicable."
::= { wsLinkStateAlarmNotification 14 }
END