CISCOSB-rndApplications DEFINITIONS ::= BEGIN
-- Title: CISCOSB Application Private Extension
-- Version: 7.37.00.00
-- Date: 17 May 2004
IMPORTS
switch001 FROM CISCOSB-MIB
InterfaceIndexOrZero, InterfaceIndex, ifIndex FROM IF-MIB
TEXTUAL-CONVENTION,
DisplayString, RowStatus, TruthValue FROM SNMPv2-TC
Unsigned32, Counter32, IpAddress,
MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI
InetAddressType, InetAddress FROM INET-ADDRESS-MIB;
rndApplications MODULE-IDENTITY
LAST-UPDATED "200406010000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
"Postal: 170 West Tasman Drive
San Jose , CA 95134-1706
USA
Website: Cisco Small Business Support Community <http://www.cisco.com/go/smallbizsupport>"
DESCRIPTION
"The private MIB module definition for switch001 applications MIB."
REVISION "200406010000Z"
DESCRIPTION
"Initial version of this MIB."
::= { switch001 35 }
-- Obsolete
-- rsServerDispatcher OBJECT IDENTIFIER ::= { rndApplications 1}
-- rndMidLevelManagement group contains variables which direct the mid-level
-- management stations how to monitor and manage their domains.
rndMidLevelManagement OBJECT IDENTIFIER ::= { rndApplications 2} -- NEW Group
rndAlarmOptions OBJECT IDENTIFIER ::= { rndMidLevelManagement 2}
rndAlarmEnabling OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether alarms should be issued to the high-level
NMS "
::= { rndAlarmOptions 1 }
rndAlarmInterval OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the minimal period of time which must pass after issuing
an alarm before issuing the same alarm again."
::= { rndAlarmOptions 2 }
rndMonitoredElementsTable OBJECT-TYPE
SYNTAX SEQUENCE OF RndMonitoredElementEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of monitored elements of the network"
::= {rndMidLevelManagement 3}
rndMonitoredElementEntry OBJECT-TYPE
SYNTAX RndMonitoredElementEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The row definition for this table."
INDEX { rndMonitoredElementAddress }
::= {rndMonitoredElementsTable 1}
RndMonitoredElementEntry ::= SEQUENCE {
rndMonitoredElementAddress IpAddress,
rndMonitoredElementCommunity DisplayString(SIZE(1..20)),
rndMonitoredElementLabel DisplayString(SIZE(1..20)),
rndDefaultPollingInterval INTEGER,
rndDefaultLogFile DisplayString,
rndMonitoredElementStatus RowStatus
}
rndMonitoredElementAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address of the monitored element"
::= {rndMonitoredElementEntry 1 }
rndMonitoredElementCommunity OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The community of the monitored element"
::= {rndMonitoredElementEntry 2 }
rndMonitoredElementLabel OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The label assigned by the network manager to the monitored element"
::= {rndMonitoredElementEntry 3}
rndDefaultPollingInterval OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The default period of time between two consecutive pollings of the
monitored element for the value of an object instance. If no other polling
interval is specifically assigned to the monitored object instance, this
one will be used"
::= {rndMonitoredElementEntry 4}
rndDefaultLogFile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The default file path of the log-file which will contain the polling
results for the monitored element. If no other file path is specifically
assigned to the monitored object instance, this log-file will be used."
::= {rndMonitoredElementEntry 5}
rndMonitoredElementStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It is used to manage the monitored elements table and indicates
the current monitoring status of an element."
::= {rndMonitoredElementEntry 6}
rndMonitoringTable OBJECT-TYPE
SYNTAX SEQUENCE OF RndMonitoringEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of monitored object instances. Each monitored object instance
belongs to a monitored element previously entered in the
rndMonitoredElementsTable. "
::= {rndMidLevelManagement 4}
rndMonitoringEntry OBJECT-TYPE
SYNTAX RndMonitoringEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The row definition for this table."
INDEX { rndMonitoredElement, IMPLIED rndMonitoredObjectInstanceLabel }
::= {rndMonitoringTable 1}
RndMonitoringEntry ::= SEQUENCE {
rndMonitoredElement DisplayString(SIZE(1..20)),
rndMonitoredObjectInstanceLabel DisplayString,
rndMonitoredObjectName DisplayString,
rndMonitoredObjectIdentifier OBJECT IDENTIFIER,
rndMonitoredObjectInstance OBJECT IDENTIFIER,
rndMonitoredObjectSyntax INTEGER,
rndMonitoringInterval INTEGER,
rndAlarmMaxTreshold INTEGER,
rndAlarmMinTreshold INTEGER,
rndMonitoringLogfile DisplayString,
rndMonitoringEntryStatus RowStatus,
rndMonitoredIntegerInstance INTEGER
}
rndMonitoredElement OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A label assigned by the network manager to a monitored element to
which this monitored object instance belongs. This label must have
been previously entered in an instance of rndMonitoredElementLabel"
::= {rndMonitoringEntry 1}
rndMonitoredObjectInstanceLabel OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The label assigned by the network manager to the monitored object instance"
::= {rndMonitoringEntry 2}
rndMonitoredObjectName OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The symbolic object type name of the object to which the monitored object
instance belongs (as it appears the MIB module definition). In case of
ambiguity the <MIB module name> : <object type name> format should be used.
An instance of rndMonitoredObjectName need not be assigned any value, if
the corresponding instance of rndMonitoredObjectIdentifier is assigned a
value, since any one of these, together with the object instance
identifier, suffices to unambigously identify the monitored object
instance."
::= {rndMonitoringEntry 3}
rndMonitoredObjectIdentifier OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object identifier of the object to which the monitored object
instance belongs.
An instance of rndMonitoredObjectIdentifier need not be assigned any value, if
the corresponding instance of rndMonitoredObjectName is assigned a value,
since any one of these, together with the object instance identifier,
suffices to unambigously identify the monitored object instance."
::= {rndMonitoringEntry 4}
rndMonitoredObjectInstance OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The instance identifier (key) of the monitored object instance."
::= {rndMonitoringEntry 5}
rndMonitoredObjectSyntax OBJECT-TYPE
SYNTAX INTEGER {
integer(1),
octet-string(2),
ip-address(3),
object-identifier(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The syntax of the monitored object instance (i.e., the syntax of the object
type of the object to which the monitored instance belongs).
Need not be assigned any value if the corresponding instance of
rndMonitoredObjectName has been assigned a value"
::= {rndMonitoringEntry 6}
rndMonitoringInterval OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The period of time between two consecutive retrievals of the monitored
object instance's value."
::= {rndMonitoringEntry 7}
rndAlarmMaxTreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the monitored object instance, the exceeding of which
will cause the generation of an alarm to the high-level management
station."
::= {rndMonitoringEntry 8}
rndAlarmMinTreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If the value of the monitored object instance falls below the value
assigned to rndAlarmMinTreshold, an alarm to the high-level management
station will be issued."
::= {rndMonitoringEntry 9}
rndMonitoringLogfile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The entire path of the file in which the results of the monitoring
of this object instance should be recorded."
::= {rndMonitoringEntry 10}
rndMonitoringEntryStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It is used to manage the monitored object instances table and
indicates the current monitoring status of an object instance."
::= {rndMonitoringEntry 11}
rndMonitoredIntegerInstance OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= {rndMonitoringEntry 12}
rndMibFilesTable OBJECT-TYPE
SYNTAX SEQUENCE OF RndMibFileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of monitored object instances. Each monitored object instance
belongs to a monitored element previously entered in the
rndMonitoredElementsTable. "
::= {rndMidLevelManagement 5}
rndMibFileEntry OBJECT-TYPE
SYNTAX RndMibFileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The row definition for this table."
INDEX { rndMibFileIndex }
::= {rndMibFilesTable 1}
RndMibFileEntry ::= SEQUENCE {
rndMibFileIndex INTEGER,
rndMibFilePath DisplayString,
rndMibFileRefresh INTEGER,
rndMibFileEntryStatus RowStatus
}
rndMibFileIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the MIB file in the list MIB files supported by the
Mid-Level management station. The order of the MIB files in this
list must reflect the the IMPORT relation between the MIBS contained
in the MIB files, i.e., if MIB A IMPORTS FROM MIB B, the file containing
MIB A must have a lesser index in this table than the file containing
MIB B."
::= {rndMibFileEntry 1}
rndMibFilePath OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The path of the MIB file in the MIB file server."
::= {rndMibFileEntry 2}
rndMibFileRefresh OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates if the file should be fetched after setting this entry from the
MIB file server."
::= {rndMibFileEntry 3}
rndMibFileEntryStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It is used to manage the MIB files table."
::= {rndMibFileEntry 4}
rndHardwareConfiguration OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the current SET SNMP PDU contains hardware
configuration (i.e., normally read-only variables). SET of such
variables in the Mid-level management station will be allowed only
if this variable is included in the SNMP PDU and its value is true.
Its value as returned in a GET SNMP PDU will always be false."
::= {rndMidLevelManagement 6}
rndEraseSimulatedConfiguration OBJECT-TYPE
SYNTAX INTEGER {
eraseSimulatedConfiguration(1),
simulatedConfigurationPresent(2),
simulatedConfigurationErased(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"eraseSimulatedConfiguration instructs the MLNMS to erase all the
simulated configuration from its configuration data-base (CDB). This
the only accepted value for SNMP SET statements and will never be
returned in SNMP GET statements.
simulatedConfigurationPresent indicates that the MLNMS currently has
a simulated configuration.
simulatedConfigurationErased indicates that the MLNMS currently has
no simulated configuration."
::= {rndMidLevelManagement 7}
rndDeleteValuesTable OBJECT-TYPE
SYNTAX SEQUENCE OF RndDeleteValuesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table indicates which MIB variables are row status fields which
control the status of the entry to which they belong. This table also
indicates which (integer!) value of these MIB variables will cause, if
present in a SNMP SET PDU, the deletion of the conceptual row instance
to which the SET MIB variable instance belongs."
::= {rndMidLevelManagement 8}
rndDeleteValuesEntry OBJECT-TYPE
SYNTAX RndDeleteValuesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The row definition for the rndDeleteValuesTable table."
INDEX { IMPLIED rndRowStatusVariableName }
::= {rndDeleteValuesTable 1}
RndDeleteValuesEntry ::= SEQUENCE {
rndRowStatusVariableName DisplayString,
rndRowStatusObjectId OBJECT IDENTIFIER,
rndRowDeleteValue INTEGER,
rndDeleteValueEntryStatus RowStatus
}
rndRowStatusVariableName OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..80))
-- MAX-ACCESS read-only
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the row status field. This name may not necessarily be any
name which is present in the MIBs loaded into the MLNMS station."
::= {rndDeleteValuesEntry 1}
rndRowStatusObjectId OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object id of the row status field. If the rndRowStatusVariableName is
a name present in the MIBs loaded into the MLNMS, this MIB
variable is not required, but if given, it must match the object id known
to the MLNMS.
The variable identified by rndRowStatusVariableName and/or rndRowStatusObjectId
must be a read-write MIB variable of type INTEGER which belongs to an
entry (i.e, is a child of a MIB variable of type SEQUENCE)."
::= {rndDeleteValuesEntry 2}
rndRowDeleteValue OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the variable identified by rndRowStatusVariableName and/or
rndRowStatusObjectId, which, if present in a SNMP SET PDU, will cause
the deletion of the conceptual row instance which the SET MIB variable
instance belongs."
::= {rndDeleteValuesEntry 3}
rndDeleteValueEntryStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It is used to delete an entry from this table."
::= {rndDeleteValuesEntry 4}
snmpTesting OBJECT IDENTIFIER ::= { rndMidLevelManagement 9}
rndSimulatedVariablesTable OBJECT-TYPE
SYNTAX SEQUENCE OF RndSimulatedVariablesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table indicates which MIB variables are simulated."
::= {snmpTesting 1}
rndSimulatedVariablesEntry OBJECT-TYPE
SYNTAX RndSimulatedVariablesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The row definition for the rndSimulatedVariablesTable table."
INDEX { rndSimulatedVariableEntryIndex }
::= {rndSimulatedVariablesTable 1}
RndSimulatedVariablesEntry ::= SEQUENCE {
rndSimulatedVariableEntryIndex INTEGER,
rndSimulatedVariableObjectId OBJECT IDENTIFIER,
rndNotSupportedField INTEGER,
rndSimulatedVariableEntryStatus RowStatus
}
rndSimulatedVariableEntryIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index entry."
::= {rndSimulatedVariablesEntry 1}
rndSimulatedVariableObjectId OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object id of the simulated variable. If the simulated variable belongs
to a table entry, the entire entry is henceforth supported."
::= {rndSimulatedVariablesEntry 2}
rndNotSupportedField OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Variable for not supported simulation."
::= {rndSimulatedVariablesEntry 3}
rndSimulatedVariableEntryStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It is used to delete an entry from this table."
::= {rndSimulatedVariablesEntry 4}
rndSnmpTestPassword OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable enables the user supplying the correct code to use the
SNMP test feature."
::= {snmpTesting 2}
rndSnmpTests OBJECT-TYPE
SYNTAX INTEGER {
noSimulation(1),
simulateSetFailure(2),
simulateAppGet(3),
simulateAppGetNext(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable enables the authorized user to test various SNMP features."
::= {snmpTesting 3}
rndSimulateUndo OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable enables the authorized user to test the SNMP UNDO feature."
::= {snmpTesting 4}
rlSnmpServTestRequest OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable enables the authorized user to test the SNMP SERV package."
::= {snmpTesting 5}
rlSnmpServTestResponse OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable enables the authorized user to retrieve the results of
a the SNMP SERV package test."
::= {snmpTesting 6}
rlSnmpServCreateTestPool OBJECT-TYPE
SYNTAX INTEGER { create(1), no-create(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable enables the authorized user to indicate that after its reset
the device should create a buffer pool for SNMPServ process PDU
testing."
::= {snmpTesting 7}
rlSnmpServITCbindClients OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable enables the authorized user to to indicate that after
its reset the device should create ITC clients for SnmpServ data
requests clients.
The semantics of this variable is as follows:
subidentifier 2*n indicates whether the client n is synchronous(1) or
asynchronous(2)
subidentifier 2*n+1 indicates the number of simulatneous requests
expected by client n."
::= {snmpTesting 8}
rlSnmpTestSimulatedVariables OBJECT IDENTIFIER ::= {snmpTesting 9}
rlTstBasicRateTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlTstBasicRateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table for testing SNMP agent."
::= { snmpTesting 10 }
rlTstBasicRateEntry OBJECT-TYPE
SYNTAX RlTstBasicRateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the rlTstBasicRateTable."
INDEX { ifIndex }
::= { rlTstBasicRateTable 1 }
RlTstBasicRateEntry ::= SEQUENCE {
rlTstBasicRateIfType INTEGER,
rlTstBasicRateLineTopology INTEGER,
rlTstBasicRateIfMode INTEGER,
rlTstBasicRateSignalMode INTEGER
}
rlTstBasicRateIfType OBJECT-TYPE
SYNTAX INTEGER {
isdns(75),
isdnu(76)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { rlTstBasicRateEntry 1 }
rlTstBasicRateLineTopology OBJECT-TYPE
SYNTAX INTEGER {
pointToPoint(1),
pointToMultipoint(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { rlTstBasicRateEntry 2 }
rlTstBasicRateIfMode OBJECT-TYPE
SYNTAX INTEGER {
te(1),
nt(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { rlTstBasicRateEntry 3 }
rlTstBasicRateSignalMode OBJECT-TYPE
SYNTAX INTEGER {
active(1),
inactive(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { rlTstBasicRateEntry 4 }
rlMibTree OBJECT IDENTIFIER ::= {rndMidLevelManagement 10 }
rlMibTreeTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlMibTreeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This reflects the MIB tree of the device."
::= {rlMibTree 1 }
rlMibTreeEntry OBJECT-TYPE
SYNTAX RlMibTreeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Each row shows a tree relationsship in the MIB."
INDEX { rlMibTreeFather, rlMibTreeSonIndex }
::= {rlMibTreeTable 1 }
RlMibTreeEntry ::= SEQUENCE {
rlMibTreeFather DisplayString,
rlMibTreeSonIndex INTEGER,
rlMibTreeSon DisplayString,
rlMibTreeSonObjectId OBJECT IDENTIFIER,
rlMibTreeGrandFather DisplayString
}
rlMibTreeFather OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The father in a tree relation ship."
::= {rlMibTreeEntry 1 }
rlMibTreeSonIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" Running index for this table."
::= {rlMibTreeEntry 2 }
rlMibTreeSon OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The son in a tree relation ship."
::= {rlMibTreeEntry 3 }
rlMibTreeSonObjectId OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The object identifier of the son in a tree relation ship."
::= {rlMibTreeEntry 4}
rlMibTreeGrandFather OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The grand father (i.e father's father) in a tree relation ship."
::= {rlMibTreeEntry 5 }
rlMibInstances OBJECT IDENTIFIER ::= {rndMidLevelManagement 11 }
rlMibTableInstancesInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlMibTableInstancesInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table for retreiving information on the current instances in a requested MIB table."
::= {rlMibInstances 1 }
rlMibTableInstancesInfoEntry OBJECT-TYPE
SYNTAX RlMibTableInstancesInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row with index rlMibTableInstancesInfoTableName = 'xTable' contains
information on current instances in 'xTable'."
INDEX { IMPLIED rlMibTableInstancesInfoTableName }
::= {rlMibTableInstancesInfoTable 1 }
RlMibTableInstancesInfoEntry ::= SEQUENCE {
rlMibTableInstancesInfoTableName DisplayString,
rlMibTableInstancesInfoNumOfInstances INTEGER
}
rlMibTableInstancesInfoTableName OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..160))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The name of the MIB table (for examle: snmpCommunityTable)"
::= {rlMibTableInstancesInfoEntry 1 }
rlMibTableInstancesInfoNumOfInstances OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Get operation on this object will retreive the current number of instances
in the MIB table specified by the index rlMibTableInstancesInfoTableName."
::= {rlMibTableInstancesInfoEntry 2 }
-- Obsolete
-- rsIpZeroHopRouting OBJECT IDENTIFIER ::= { rndApplications 3}
rsPingMIB OBJECT IDENTIFIER ::= { rndApplications 4} -- NEW Group
--------------------------------------------------------------------------------
-- rsPingTable
--------------------------------------------------------------------------------
--
-- Textual Conventions
--
PingCompletionStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "If all the echo request packets in this sequence have been
responded by valid echo responses, this object is set to ok.
Otherwise this status indicates the problem. bad-reply-data indicates
that the reply data is not equal to the response data."
SYNTAX INTEGER {
ok(1),
timeout(2),
net-unreachable(3),
host-unreachable(4),
protocol-unreachable(5),
time-to-live-exceeded(6),
reassembly-time-exceeded(7),
unable-to-send(8),
bad-reply-data(9),
incomplete(10)
}
rsPingTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of ping request entries."
::= { rsPingMIB 1 }
rsPingEntry OBJECT-TYPE
SYNTAX RsPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A ping request entry.
A management station wishing to create an entry should
first generate a pseudo-random serial number to be used
as the index to this sparse table. It must also create in the same
PDU the associated instance of the address object. It should also
modify in the same PDU the default values for the other configuration
objects if the defaults are not appropriate.
Once the sequence completes, the management station should
retrieve the values of the status objects of interest, and
should then delete the entry. In order to prevent old
entries from clogging the table, entries will be aged out,
but an entry will never be deleted within 5 minutes of
completing."
INDEX { rsPingAddress }
::= { rsPingTable 1 }
RsPingEntry ::= SEQUENCE {
rsPingAddress IpAddress,
rsPingPacketCount INTEGER,
rsPingPacketSize INTEGER,
rsPingPacketTimeout INTEGER,
rsPingDelay INTEGER,
rsPingTrapOnCompletion TruthValue,
rsPingSentPackets Counter32,
rsPingReceivedPackets Counter32,
rsPingMinReturnTime INTEGER,
rsPingAvgReturnTime INTEGER,
rsPingMaxReturnTime INTEGER,
rsPingCompletionStatus PingCompletionStatus,
rsPingTimeStamp DisplayString,
rsPingEntryStatus RowStatus
}
rsPingAddress OBJECT-TYPE
SYNTAX IpAddress
-- Rsyntax OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The address of the device to be pinged.
Once an instance of this object is created, its
value can not be changed."
::= { rsPingEntry 1 }
rsPingPacketCount OBJECT-TYPE
SYNTAX INTEGER(1..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the number of ping packets to send to the target
in this sequence."
-- DEFVAL { 5 }
::= { rsPingEntry 2 }
rsPingPacketSize OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the size of ping packets to send to the target
in this sequence. The lower and upper boundaries of this
object are implementation dependent."
-- DEFVAL { 100 }
::= { rsPingEntry 3 }
rsPingPacketTimeout OBJECT-TYPE
SYNTAX INTEGER(0..3600000)
-- Units
-- milliseconds
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the amount of time to wait for a response to a
transmitted packet before declaring the packet 'dropped.'"
-- DEFVAL { 2000 }
::= { rsPingEntry 4 }
rsPingDelay OBJECT-TYPE
SYNTAX INTEGER(0..3600000)
-- Units
-- milliseconds
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the minimum amount of time to wait before sending
the next packet in a sequence after receiving a response.
The actual delay may be greater due to internal task scheduling."
-- DEFVAL { 0 }
::= { rsPingEntry 5 }
rsPingTrapOnCompletion OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies whether or not a rsPingCompletion trap should
be issued on completion of the sequence of pings. If such a
trap is desired, the NMS should ensure that the community table
contains an instance specified by the NMSs IP address with
rndCommunityTrapsEnable = trapsEnable."
-- DEFVAL { false }
::= { rsPingEntry 6 }
rsPingSentPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ping packets that have been sent to the target
in this sequence."
::= { rsPingEntry 7 }
rsPingReceivedPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ping packets that have been received from the
target in this sequence."
::= { rsPingEntry 8 }
rsPingMinReturnTime OBJECT-TYPE
SYNTAX INTEGER
-- Units
-- milliseconds
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum round trip time of all the packets that have
been sent in this sequence. The value returned to a GET request
is meaningless if no ping response in a sequence has been received
yet."
::= { rsPingEntry 9 }
rsPingAvgReturnTime OBJECT-TYPE
SYNTAX INTEGER
-- Units
-- milliseconds
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average round trip time of all the packets that have
been sent in this sequence.The value returned to a GET request
is meaningless if no ping response in a sequence has been received
yet."
::= { rsPingEntry 10 }
rsPingMaxReturnTime OBJECT-TYPE
SYNTAX INTEGER
-- Units
-- milliseconds
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum round trip time of all the packets that have
been sent in this sequence.The value returned to a GET request
is meaningless if no ping response in a sequence has been received
yet."
::= { rsPingEntry 11 }
rsPingCompletionStatus OBJECT-TYPE
SYNTAX PingCompletionStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If all the echo request packets in this sequence have been
responded by valid echo responses, this object is set to ok.
Otherwise this status indicates the problem. bad-reply-data indicates
that the reply data is not equal to the response data."
::= { rsPingEntry 12 }
rsPingTimeStamp OBJECT-TYPE
SYNTAX DisplayString(SIZE(19))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time-stamp indicating the time and date of creation or last
update of this request. The format of the time-stamp is
dd/mm/yyyy hh:mm:ss"
::= { rsPingEntry 13 }
rsPingEntryStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of this table entry."
::= { rsPingEntry 14 }
--------------------------------------------------------------------------------
-- rsPingInetTable
--------------------------------------------------------------------------------
-- For IPv6 support
-- Must replace old rsPingTable MIB
rsPingInetTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsPingInetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of ping request entries."
::= { rsPingMIB 2 }
rsPingInetEntry OBJECT-TYPE
SYNTAX RsPingInetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A ping request entry.
A management station wishing to create an entry should
first generate a pseudo-random serial number to be used
as the index to this sparse table. It must also create in the same
PDU the associated instance of the address object. It should also
modify in the same PDU the default values for the other configuration
objects if the defaults are not appropriate.
Once the sequence completes, the management station should
retrieve the values of the status objects of interest, and
should then delete the entry. In order to prevent old
entries from clogging the table, entries will be aged out,
but an entry will never be deleted within 5 minutes of
completing."
INDEX { rsPingInetAddressType, rsPingInetAddress }
::= { rsPingInetTable 1 }
RsPingInetEntry ::= SEQUENCE {
rsPingInetAddressType InetAddressType,
rsPingInetAddress InetAddress,
rsPingInetPacketCount INTEGER,
rsPingInetPacketSize INTEGER,
rsPingInetPacketTimeout INTEGER,
rsPingInetDelay INTEGER,
rsPingInetTrapOnCompletion TruthValue,
rsPingInetSentPackets Counter32,
rsPingInetReceivedPackets Counter32,
rsPingInetMinReturnTime INTEGER,
rsPingInetAvgReturnTime INTEGER,
rsPingInetMaxReturnTime INTEGER,
rsPingInetCompletionStatus PingCompletionStatus,
rsPingInetTimeStamp DisplayString,
rsPingInetEntryStatus RowStatus,
rsPingInetSourceAddr InetAddress
}
rsPingInetAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The address type of the device to be pinged.
Once an instance of this object is created, its
value can not be changed."
::= { rsPingInetEntry 1 }
rsPingInetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The address of the device to be pinged.
Once an instance of this object is created, its
value can not be changed."
::= { rsPingInetEntry 2 }
rsPingInetPacketCount OBJECT-TYPE
SYNTAX INTEGER(1..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the number of ping packets to send to the target
in this sequence."
::= { rsPingInetEntry 3 }
rsPingInetPacketSize OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the size of ping packets to send to the target
in this sequence. The lower and upper boundaries of this
object are implementation dependent."
::= { rsPingInetEntry 4 }
rsPingInetPacketTimeout OBJECT-TYPE
SYNTAX INTEGER(0..3600000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the amount of time (in milliseconds) to wait for a response to a
transmitted packet before declaring the packet 'dropped.'"
::= { rsPingInetEntry 5 }
rsPingInetDelay OBJECT-TYPE
SYNTAX INTEGER(0..3600000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the minimum amount of time (in milliseconds) to wait before sending
the next packet in a sequence after receiving a response.
The actual delay may be greater due to internal task scheduling."
::= { rsPingInetEntry 6 }
rsPingInetTrapOnCompletion OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies whether or not a rsPingCompletion trap should
be issued on completion of the sequence of pings. If such a
trap is desired, the NMS should ensure that the community table
contains an instance specified by the NMSs IP address with
rndCommunityTrapsEnable = trapsEnable."
::= { rsPingInetEntry 7 }
rsPingInetSentPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of ping packets that have been sent to the target
in this sequence."
::= { rsPingInetEntry 8 }
rsPingInetReceivedPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of ping packets that have been received from the
target in this sequence."
::= { rsPingInetEntry 9 }
rsPingInetMinReturnTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The minimum round trip time (in milliseconds) of all the packets that have
been sent in this sequence. The value returned to a GET request
is meaningless if no ping response in a sequence has been received yet."
::= { rsPingInetEntry 10 }
rsPingInetAvgReturnTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The average round trip time (in milliseconds) of all the packets that have
been sent in this sequence.The value returned to a GET request
is meaningless if no ping response in a sequence has been received yet."
::= { rsPingInetEntry 11 }
rsPingInetMaxReturnTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum round trip time (in milliseconds) of all the packets that have
been sent in this sequence.The value returned to a GET request
is meaningless if no ping response in a sequence has been received yet."
::= { rsPingInetEntry 12 }
rsPingInetCompletionStatus OBJECT-TYPE
SYNTAX PingCompletionStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "If all the echo request packets in this sequence have been
responded by valid echo responses, this object is set to ok.
Otherwise this status indicates the problem. bad-reply-data indicates
that the reply data is not equal to the response data."
::= { rsPingInetEntry 13 }
rsPingInetTimeStamp OBJECT-TYPE
SYNTAX DisplayString(SIZE(19))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The time-stamp indicating the time and date of creation or last
update of this request. The format of the time-stamp is
dd/mm/yyyy hh:mm:ss"
::= { rsPingInetEntry 14 }
rsPingInetEntryStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The status of this table entry."
::= { rsPingInetEntry 15 }
rsPingInetSourceAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The status of this table entry."
::= { rsPingInetEntry 16 }
--------------------------------------------------------------------------------
rsPowerSupplyRedundacy OBJECT IDENTIFIER ::= { rndApplications 5} -- NEW Group
rsPowerSupplyRedundacyTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsPowerSupplyRedundacyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The power supply redundancy table."
::= { rsPowerSupplyRedundacy 1 }
rsPowerSupplyRedundacyEntry OBJECT-TYPE
SYNTAX RsPowerSupplyRedundacyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The status of power supply redundancy for this table."
INDEX { rsPowerSupplyRedundacyReNumber}
::= { rsPowerSupplyRedundacyTable 1}
RsPowerSupplyRedundacyEntry ::= SEQUENCE {
rsPowerSupplyRedundacyReNumber INTEGER,
rsPowerSupplyRedundacyStatus INTEGER
}
rsPowerSupplyRedundacyReNumber OBJECT-TYPE
SYNTAX INTEGER (1..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This number identifies the module backed up
by power supply redundancy in the stack."
::= { rsPowerSupplyRedundacyEntry 1}
rsPowerSupplyRedundacyStatus OBJECT-TYPE
SYNTAX INTEGER{
notExist(1),
existButNotWorking(2),
bothWorking(3),
internalOnlyWorking(4),
externalOnlyWorking(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of a power supply redundancy of the entry."
::= { rsPowerSupplyRedundacyEntry 2}
rsNvram OBJECT IDENTIFIER ::= { rndApplications 6 }
rsEraseNvramAfterReset OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of NVRAM application that will be erased
after reset or ALL if all NVRAM should be erased."
::= { rsNvram 1 }
rsNvramApplTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsNvramApplEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The NVRAM application table."
::= { rsNvram 2 }
rsNvramApplEntry OBJECT-TYPE
SYNTAX RsNvramApplEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The status of NVRAM application table."
INDEX { rsNvramApplIndex}
::= { rsNvramApplTable 1}
RsNvramApplEntry ::= SEQUENCE {
rsNvramApplIndex INTEGER,
rsNvramApplName DisplayString
}
rsNvramApplIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of NVRAM application table."
::= { rsNvramApplEntry 1}
rsNvramApplName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of application used NVRAM."
::= { rsNvramApplEntry 2}
END