2943 lines
89 KiB
Plaintext
2943 lines
89 KiB
Plaintext
--
|
|
-- 12/23/2009 - v1.0r Dell rPDU
|
|
--
|
|
-- **********************************************************************
|
|
-- **********************************************************************
|
|
-- dellrPDU-MIB { iso org(3) dod(6) internet(1) private(4) enterprises(1)
|
|
-- dell(674) }
|
|
|
|
DellrPDU-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
enterprises, IpAddress, Gauge, TimeTicks FROM RFC1155-SMI
|
|
DisplayString FROM RFC1213-MIB
|
|
OBJECT-TYPE FROM RFC-1212
|
|
TRAP-TYPE FROM RFC-1215;
|
|
|
|
dell OBJECT IDENTIFIER ::= { enterprises 674 }
|
|
pdu OBJECT IDENTIFIER ::= { dell 10903 }
|
|
pdusub OBJECT IDENTIFIER ::= { pdu 200 }
|
|
|
|
-- 1.3.6.1.4.1.674.10903.200
|
|
|
|
software OBJECT IDENTIFIER ::= { pdusub 1 }
|
|
hardware OBJECT IDENTIFIER ::= { pdusub 2 }
|
|
system OBJECT IDENTIFIER ::= { pdusub 3 }
|
|
|
|
sysRPDUV1 OBJECT IDENTIFIER ::= { system 1 }
|
|
|
|
-- Common rPDU values
|
|
|
|
RpduEnableDisableType ::= INTEGER {
|
|
disabled (1),
|
|
enabled (2)
|
|
}
|
|
|
|
RpduNormalAlarmType ::= INTEGER {
|
|
normal (1),
|
|
alarm (2)
|
|
}
|
|
|
|
RpduCommNoneOKLostType ::= INTEGER {
|
|
notInstalled (1),
|
|
commsOK (2),
|
|
commsLost (3)
|
|
}
|
|
|
|
RpduLowNormalNearOverloadType ::= INTEGER {
|
|
lowLoad (1),
|
|
normal (2),
|
|
nearOverload (3),
|
|
overload (4)
|
|
}
|
|
|
|
RpduNotPBMinLowNrmlOHiMaxType ::= INTEGER {
|
|
notPresent (1),
|
|
belowMin (2),
|
|
belowLow (3),
|
|
normal (4),
|
|
overHigh (5),
|
|
overMax (6)
|
|
}
|
|
|
|
RpduOtherToNonrecoverableType ::= INTEGER {
|
|
other (1),
|
|
unknown (2),
|
|
ok (3),
|
|
non-critical (4),
|
|
critical (5),
|
|
non-recoverable (6)
|
|
}
|
|
|
|
RpduOutletPhaseLayoutType ::= INTEGER {
|
|
seqPhase1ToNeutral (1),
|
|
seqPhase2ToNeutral (2),
|
|
seqPhase3ToNeutral (3),
|
|
seqPhase1ToPhase2 (4),
|
|
seqPhase2ToPhase3 (5),
|
|
seqPhase3ToPhase1 (6)
|
|
}
|
|
|
|
productID OBJECT IDENTIFIER ::= { hardware 100 }
|
|
|
|
productIDDisplayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of this product for display purposes."
|
|
::= { productID 1 }
|
|
|
|
productIDDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A short description of this product."
|
|
::= { productID 2 }
|
|
|
|
productIDVendor OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the product manufacturer."
|
|
::= { productID 3 }
|
|
|
|
productIDVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware version of this product."
|
|
::= { productID 4 }
|
|
|
|
productIDBuildNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The software build number of the product populating the MIB."
|
|
::= { productID 5 }
|
|
|
|
productIDURL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The URL of the Web-based application to manage this device, should
|
|
the device provide one."
|
|
::= { productID 6 }
|
|
|
|
productIDDeviceNetworkName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Operating system-specific computer name if product SNMP service is
|
|
hosted."
|
|
::= { productID 7 }
|
|
|
|
productStatus OBJECT IDENTIFIER ::= { hardware 110 }
|
|
|
|
productStatusGlobalStatus OBJECT-TYPE
|
|
SYNTAX RpduOtherToNonrecoverableType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of the product. This is a summary of the status
|
|
for the entire product including any metered devices. The SNMP
|
|
monitor performs a get to retrieve additional data when this status
|
|
is abnormal. Valid values 1: Other 2: Unknown 3: OK 4: Non-critical
|
|
5: Critical 6: Non-recoverable."
|
|
::= { productStatus 1 }
|
|
|
|
productStatusLastGlobalStatus OBJECT-TYPE
|
|
SYNTAX RpduOtherToNonrecoverableType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status before the current status which induced an initiative to
|
|
issue a global status change trap."
|
|
::= { productStatus 2 }
|
|
|
|
productStatusTimeStamp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The last time that the SNMP table geometries changed or attribute
|
|
data was significantly updated. Management applications use this OID
|
|
to trigger a refresh of data acquired from the MIB. This time should
|
|
be a relative timestamp, for example, the value of MIB II SysUpTime
|
|
when the values are updated."
|
|
::= { productStatus 3 }
|
|
|
|
productStatusRESERVED1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RESERVED"
|
|
::= { productStatus 4 }
|
|
|
|
productStatusRESERVED2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RESERVED"
|
|
::= { productStatus 5 }
|
|
|
|
productStatusRESERVED3 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RESERVED"
|
|
::= { productStatus 6 }
|
|
|
|
|
|
rPDU OBJECT IDENTIFIER ::= { hardware 200 }
|
|
|
|
rPDUIdentD OBJECT IDENTIFIER ::= { rPDU 100 }
|
|
|
|
-- rPDU Ident Table
|
|
|
|
rPDUIdentTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of connected Rack PDUs."
|
|
::= { rPDUIdentD 1 }
|
|
|
|
rPDUIdentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUIdentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU identification data."
|
|
::= { rPDUIdentD 2 }
|
|
|
|
rPDUIdentEntry OBJECT-TYPE
|
|
SYNTAX RPDUIdentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Identification data from the Rack PDU being queried."
|
|
INDEX { rPDUIdentIndex }
|
|
::= { rPDUIdentTable 1 }
|
|
|
|
RPDUIdentEntry ::=
|
|
SEQUENCE {
|
|
rPDUIdentIndex INTEGER,
|
|
rPDUIdentNameD DisplayString,
|
|
rPDUIdentLocation DisplayString,
|
|
rPDUIdentHardwareRevD DisplayString,
|
|
rPDUIdentFirmwareRevD DisplayString,
|
|
rPDUIdentDateOfManufactureD DisplayString,
|
|
rPDUIdentModelNumberD DisplayString,
|
|
rPDUIdentSerialNumberD DisplayString
|
|
}
|
|
|
|
rPDUIdentIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU identification table entry."
|
|
::= { rPDUIdentEntry 1 }
|
|
|
|
rPDUIdentNameD OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the Rack PDU."
|
|
::= { rPDUIdentEntry 2 }
|
|
|
|
rPDUIdentLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the location of the Rack PDU."
|
|
::= { rPDUIdentEntry 3 }
|
|
|
|
rPDUIdentHardwareRevD OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU hardware version."
|
|
::= { rPDUIdentEntry 4 }
|
|
|
|
rPDUIdentFirmwareRevD OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU firmware version."
|
|
::= { rPDUIdentEntry 5 }
|
|
|
|
rPDUIdentDateOfManufactureD OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date the Rack PDU was manufactured in mm/dd/yyyy format."
|
|
::= { rPDUIdentEntry 6 }
|
|
|
|
rPDUIdentModelNumberD OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU model number."
|
|
::= { rPDUIdentEntry 7 }
|
|
|
|
rPDUIdentSerialNumberD OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Rack PDU serial number."
|
|
::= { rPDUIdentEntry 8 }
|
|
|
|
rPDUDevice OBJECT IDENTIFIER ::= { rPDU 110 }
|
|
|
|
-- rPDU Device Data
|
|
|
|
rPDUDeviceTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of connected Rack PDUs."
|
|
::= { rPDUDevice 1 }
|
|
|
|
-- rPDU Device Status
|
|
|
|
rPDUDeviceStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUDeviceStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU status information."
|
|
::= { rPDUDevice 2 }
|
|
|
|
rPDUDeviceStatusEntry OBJECT-TYPE
|
|
SYNTAX RPDUDeviceStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status information from the Rack PDU being queried."
|
|
INDEX { rPDUDeviceStatusIndex }
|
|
::= { rPDUDeviceStatusTable 1 }
|
|
|
|
RPDUDeviceStatusEntry ::=
|
|
SEQUENCE {
|
|
rPDUDeviceStatusIndex INTEGER,
|
|
rPDUDeviceStatusName DisplayString,
|
|
rPDUDeviceStatusPower INTEGER,
|
|
rPDUDeviceStatusEnergy INTEGER,
|
|
rPDUDeviceStatusCommandPending INTEGER,
|
|
rPDUDeviceStatusLoadState INTEGER
|
|
}
|
|
|
|
rPDUDeviceStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU status table entry."
|
|
::= { rPDUDeviceStatusEntry 1 }
|
|
|
|
rPDUDeviceStatusName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the Rack PDU."
|
|
::= { rPDUDeviceStatusEntry 2 }
|
|
|
|
rPDUDeviceStatusPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power consumption of the Rack PDU load in 1/100 of KWatts."
|
|
::= { rPDUDeviceStatusEntry 3 }
|
|
|
|
rPDUDeviceStatusEnergy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user resettable energy meter measuring Rack PDU load energy
|
|
consumption in tenths of kilowatt-hours."
|
|
::= { rPDUDeviceStatusEntry 4 }
|
|
|
|
rPDUDeviceStatusCommandPending OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
commandPending (1),
|
|
noCommandPending (2),
|
|
commandPendingUnknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the device is processing a pending command.
|
|
If the commandPendingUnknown (3) value is returned, all devices
|
|
receiving power from the Rack PDU should be shut down.
|
|
The Rack PDU's power should then be cycled to clear this condition."
|
|
::= { rPDUDeviceStatusEntry 5 }
|
|
|
|
rPDUDeviceStatusLoadState OBJECT-TYPE
|
|
SYNTAX RpduLowNormalNearOverloadType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the present load status of the Rack PDU Device being
|
|
queried."
|
|
::= { rPDUDeviceStatusEntry 6 }
|
|
|
|
-- rPDU Device Config
|
|
|
|
rPDUDeviceConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUDeviceConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU configuration data."
|
|
::= { rPDUDevice 3 }
|
|
|
|
rPDUDeviceConfigEntry OBJECT-TYPE
|
|
SYNTAX RPDUDeviceConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from the Rack PDU being queried."
|
|
INDEX { rPDUDeviceConfigIndex }
|
|
::= { rPDUDeviceConfigTable 1 }
|
|
|
|
RPDUDeviceConfigEntry ::=
|
|
SEQUENCE {
|
|
rPDUDeviceConfigIndex INTEGER,
|
|
rPDUDeviceConfigName DisplayString,
|
|
rPDUDeviceConfigLocation DisplayString,
|
|
rPDUDeviceConfigColdstartDelay INTEGER,
|
|
rPDUDeviceCfgLowLoadPwrThresh INTEGER,
|
|
rPDUDeviceCfgNerOvloadPwrThresh INTEGER,
|
|
rPDUDeviceCfgOverloadPwrThresh INTEGER,
|
|
rPDUDeviceConfigPowerHeadroom INTEGER,
|
|
rPDUDeviceConfigPeakPower INTEGER,
|
|
rPDUDeviceCfgPeakPwrStartTime DisplayString,
|
|
rPDUDeviceConfigPeakPwrCapTime DisplayString,
|
|
rPDUDeviceCfgPeakPowerHeadroom INTEGER,
|
|
rPDUDeviceCfgEnergyStartTime DisplayString
|
|
}
|
|
|
|
|
|
rPDUDeviceConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU table entry."
|
|
::= { rPDUDeviceConfigEntry 1 }
|
|
|
|
rPDUDeviceConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the Rack PDU."
|
|
::= { rPDUDeviceConfigEntry 2 }
|
|
|
|
rPDUDeviceConfigLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Location of the Rack PDU."
|
|
::= { rPDUDeviceConfigEntry 3 }
|
|
|
|
rPDUDeviceConfigColdstartDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of delay, measured in seconds, between when power is
|
|
provided to the Rack PDU and when the Rack PDU provides basic
|
|
master power to the outlets."
|
|
::= { rPDUDeviceConfigEntry 4 }
|
|
|
|
rPDUDeviceCfgLowLoadPwrThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined low power draw alarm threshold, measured in tenths
|
|
of kilowatts."
|
|
::= { rPDUDeviceConfigEntry 5 }
|
|
|
|
rPDUDeviceCfgNerOvloadPwrThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined near power overload threshold, measured in tenths
|
|
of kilowatts."
|
|
::= { rPDUDeviceConfigEntry 6 }
|
|
|
|
rPDUDeviceCfgOverloadPwrThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined power overload threshold, measured in tenths of
|
|
kilowatts."
|
|
::= { rPDUDeviceConfigEntry 7 }
|
|
|
|
rPDUDeviceConfigPowerHeadroom OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of input power that is available to the connected
|
|
devices in hundredths of kilowatt-hours."
|
|
::= { rPDUDeviceConfigEntry 8 }
|
|
|
|
rPDUDeviceConfigPeakPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The highest input power level recorded by the connected
|
|
devices in hundredths of kilowatt-hours."
|
|
::= { rPDUDeviceConfigEntry 9 }
|
|
|
|
rPDUDeviceCfgPeakPwrStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time, in hh:mm:ss, when the device started recording the highest
|
|
input power level."
|
|
::= { rPDUDeviceConfigEntry 10 }
|
|
|
|
rPDUDeviceConfigPeakPwrCapTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time, in hh:mm:ss, when the highest input power level was
|
|
recorded by the device."
|
|
::= { rPDUDeviceConfigEntry 11 }
|
|
|
|
rPDUDeviceCfgPeakPowerHeadroom OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The highest level of input power that is available to the connected
|
|
devices in hundredths of kilowatt-hours."
|
|
::= { rPDUDeviceConfigEntry 12 }
|
|
|
|
rPDUDeviceCfgEnergyStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time, in hh:mm:ss, when the device started recording the input
|
|
energy level."
|
|
::= { rPDUDeviceConfigEntry 13 }
|
|
|
|
-- rPDU Device Properties
|
|
|
|
rPDUDevicePropertiesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUDevicePropertiesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU properties."
|
|
::= { rPDUDevice 4 }
|
|
|
|
rPDUDevicePropertiesEntry OBJECT-TYPE
|
|
SYNTAX RPDUDevicePropertiesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Properties of the Rack PDU being queried."
|
|
INDEX { rPDUDevicePropertiesIndex }
|
|
::= { rPDUDevicePropertiesTable 1 }
|
|
|
|
RPDUDevicePropertiesEntry ::=
|
|
SEQUENCE {
|
|
rPDUDevicePropertiesIndex INTEGER,
|
|
rPDUDevicePropertiesName DisplayString,
|
|
rPDUDevicePropertiesNumOutlets INTEGER,
|
|
rPDUDevicePropertiesNumSwdOuts INTEGER,
|
|
rPDUDevicePropertiesNumMtrdOuts INTEGER,
|
|
rPDUDevicePropertiesNumPhases INTEGER,
|
|
rPDUDevicePropertiesNumBreakers INTEGER,
|
|
rPDUDevicePropertiesMaxCurntRtg INTEGER,
|
|
rPDUDevicePropertiesOutlayout INTEGER
|
|
}
|
|
|
|
rPDUDevicePropertiesIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU properties table entry."
|
|
::= { rPDUDevicePropertiesEntry 1 }
|
|
|
|
rPDUDevicePropertiesName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the Rack PDU."
|
|
::= { rPDUDevicePropertiesEntry 2 }
|
|
|
|
rPDUDevicePropertiesNumOutlets OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of outlets on the Rack PDU."
|
|
::= { rPDUDevicePropertiesEntry 3 }
|
|
|
|
rPDUDevicePropertiesNumSwdOuts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of switched outlets on the Rack PDU."
|
|
::= { rPDUDevicePropertiesEntry 4 }
|
|
|
|
rPDUDevicePropertiesNumMtrdOuts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of metered outlets on the Rack PDU."
|
|
::= { rPDUDevicePropertiesEntry 5 }
|
|
|
|
rPDUDevicePropertiesNumPhases OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of phases present in the Rack PDU."
|
|
::= { rPDUDevicePropertiesEntry 6 }
|
|
|
|
rPDUDevicePropertiesNumBreakers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of breakers present in the Rack PDU."
|
|
::= { rPDUDevicePropertiesEntry 7 }
|
|
|
|
rPDUDevicePropertiesMaxCurntRtg OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum current rating, measured in Amps, for the Rack PDU."
|
|
::= { rPDUDevicePropertiesEntry 8 }
|
|
|
|
rPDUDevicePropertiesOutlayout OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
phaseToNeutral (1),
|
|
phaseToPhase (2),
|
|
phaseToNeutralGrouped (3),
|
|
phaseToPhaseGrouped (4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The phase wiring for the Rack PDU outlets. PhaseToNeutral and
|
|
PhaseToPhase: outlets wired consecutively; PhaseToNeutralGrouped
|
|
and PhaseToPhaseGrouped: groups of outlets wired consecutively."
|
|
::= { rPDUDevicePropertiesEntry 9 }
|
|
|
|
-- rPDU Device Control
|
|
|
|
rPDUDeviceControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUDeviceControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU control data."
|
|
::= { rPDUDevice 5 }
|
|
|
|
rPDUDeviceControlEntry OBJECT-TYPE
|
|
SYNTAX RPDUDeviceControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control data from the Rack PDU being queried."
|
|
INDEX { rPDUDeviceControlIndex }
|
|
::= { rPDUDeviceControlTable 1 }
|
|
|
|
RPDUDeviceControlEntry ::=
|
|
SEQUENCE {
|
|
rPDUDeviceControlIndex INTEGER,
|
|
rPDUDeviceControlName DisplayString,
|
|
rPDUDeviceControlCommand INTEGER
|
|
}
|
|
|
|
rPDUDeviceControlIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU control table entry."
|
|
::= { rPDUDeviceControlEntry 1 }
|
|
|
|
rPDUDeviceControlName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user-defined string identifying the Rack PDU."
|
|
::= { rPDUDeviceControlEntry 2 }
|
|
|
|
rPDUDeviceControlCommand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turnAllOnNow (1),
|
|
turnAllOnSequence (2),
|
|
turnAllOffNow (3),
|
|
rebootAllNow (4),
|
|
rebootAllSequence (5),
|
|
noCommand (6),
|
|
turnAllOffSequence (7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this OID to turnAllOnNow (1) will turn all outlets on
|
|
immediately. Setting this OID to turnAllOnSequence (2) will turn
|
|
all outlets on as defined by each outlet's sPDUOutletPowerOnTime
|
|
OID value. Setting this OID to turnAllOff (3) will turn all outlets
|
|
off immediately. Setting this OID to rebootAllNow (4) will reboot
|
|
all outlets immediately. Setting this OID to rebootAllSequence (5)
|
|
reboots all outlets, with power returned to the outlets in the
|
|
sequence defined by each outlet's rPDUOutSwitchedCfgPowerOnTime
|
|
OID value. Setting this OID to rebootAllSequence (5) will cause a
|
|
turnAllOffSequence to be performed. Once all outlets are off, the
|
|
Rack PDU will then delay the rPDUOutSwtchedCfgRebootDuration
|
|
OID time, and then perform a turnAllOnSequence. Setting this OID
|
|
to turnAllOffSequence (7) will turn all outlets off as defined by
|
|
each outlet's rPDUOutSwitchedCfgPowerOffTime OID value.
|
|
Getting this OID will return the noCommand (6) value."
|
|
::= { rPDUDeviceControlEntry 3 }
|
|
|
|
rPDUPhase OBJECT IDENTIFIER ::= { rPDU 120 }
|
|
|
|
-- rPDU Phase Data
|
|
|
|
rPDUPhaseTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of connected Rack PDU phases."
|
|
::= { rPDUPhase 1 }
|
|
|
|
-- rPDU Phase Status
|
|
|
|
rPDUPhaseStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUPhaseStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU phase status data."
|
|
::= { rPDUPhase 2 }
|
|
|
|
rPDUPhaseStatusEntry OBJECT-TYPE
|
|
SYNTAX RPDUPhaseStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status data from the currently queried Rack PDU phase."
|
|
INDEX { rPDUPhaseStatusIndex }
|
|
::= { rPDUPhaseStatusTable 1 }
|
|
|
|
RPDUPhaseStatusEntry ::=
|
|
SEQUENCE {
|
|
rPDUPhaseStatusIndex INTEGER,
|
|
rPDUPhaseStatusNumber INTEGER,
|
|
rPDUPhaseStatusLoadState INTEGER,
|
|
rPDUPhaseStatusCurrent INTEGER,
|
|
rPDUPhaseStatusVoltage INTEGER,
|
|
rPDUPhaseStatusPower INTEGER
|
|
}
|
|
|
|
rPDUPhaseStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU phase status table entry."
|
|
::= { rPDUPhaseStatusEntry 1 }
|
|
|
|
rPDUPhaseStatusNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric phase ID."
|
|
::= { rPDUPhaseStatusEntry 2 }
|
|
|
|
rPDUPhaseStatusLoadState OBJECT-TYPE
|
|
SYNTAX RpduLowNormalNearOverloadType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the present load status of the Rack PDU phase being
|
|
queried."
|
|
::= { rPDUPhaseStatusEntry 3 }
|
|
|
|
rPDUPhaseStatusCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the current draw, in tenths of Amps, of the load on
|
|
the Rack PDU phase being queried."
|
|
::= { rPDUPhaseStatusEntry 4 }
|
|
|
|
rPDUPhaseStatusVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the Voltage, in Volts, of the Rack PDU
|
|
phase being queried."
|
|
::= { rPDUPhaseStatusEntry 5 }
|
|
|
|
rPDUPhaseStatusPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the load power, in hundredths of kilowatts, consumed on
|
|
the Rack PDU phase being queried."
|
|
::= { rPDUPhaseStatusEntry 6 }
|
|
|
|
-- rPDU Phase Config
|
|
|
|
rPDUPhaseConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUPhaseConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU phase configuration data."
|
|
::= { rPDUPhase 3 }
|
|
|
|
rPDUPhaseConfigEntry OBJECT-TYPE
|
|
SYNTAX RPDUPhaseConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from the currently queried Rack PDU phase."
|
|
INDEX { rPDUPhaseConfigIndex }
|
|
::= { rPDUPhaseConfigTable 1 }
|
|
|
|
RPDUPhaseConfigEntry ::=
|
|
SEQUENCE {
|
|
rPDUPhaseConfigIndex INTEGER,
|
|
rPDUPhaseConfigNumber INTEGER,
|
|
rPDUPhaseCfgOverloadRestriction INTEGER,
|
|
rPDUPhCfgLowLoadCurntThreshold INTEGER,
|
|
rPDUPhCfgNerOverloadCurntThresh INTEGER,
|
|
rPDUPhCfgOverloadCurntThreshold INTEGER
|
|
}
|
|
|
|
rPDUPhaseConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU phase configuration table entry."
|
|
::= { rPDUPhaseConfigEntry 1 }
|
|
|
|
rPDUPhaseConfigNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric phase ID."
|
|
::= { rPDUPhaseConfigEntry 2 }
|
|
|
|
rPDUPhaseCfgOverloadRestriction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alwaysAllowTurnON (1),
|
|
restrictOnNearOverload (2),
|
|
restrictOnOverload (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID controls the behavior of a Switched Rack PDU phase
|
|
when an overload condition is possible and additional outlets
|
|
are requested to be turned on. Setting this OID to
|
|
alwaysAllowTurnON (1) will always allow the outlets on the
|
|
corresponding phase to turn on. Setting this OID to
|
|
restrictOnNearOverload (2) will not allow outlets on the
|
|
corresponding phase to turn on if the
|
|
rPDULoadConfigNearOverloadThreshold OID is exceeded. Setting
|
|
this OID to restrictOnOverload (3) will not allow outlets on the
|
|
corresponding phase to turn on if the
|
|
rPDULoadConfigOverloadThreshold OID is exceeded."
|
|
::= { rPDUPhaseConfigEntry 3 }
|
|
|
|
rPDUPhCfgLowLoadCurntThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined threshold for low phase current load, in Amps."
|
|
::= { rPDUPhaseConfigEntry 4 }
|
|
|
|
rPDUPhCfgNerOverloadCurntThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined near phase overload warning threshold in Amps."
|
|
::= { rPDUPhaseConfigEntry 5 }
|
|
|
|
rPDUPhCfgOverloadCurntThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined phase overload current threshold in Amps."
|
|
::= { rPDUPhaseConfigEntry 6 }
|
|
|
|
rPDUOutlet OBJECT IDENTIFIER ::= { rPDU 130 }
|
|
|
|
-- rPDU Outlet Data
|
|
|
|
rPDUOutletSwitched OBJECT IDENTIFIER ::= { rPDUOutlet 1 }
|
|
|
|
-- rPDU Switched Outlet Data
|
|
|
|
rPDUOutletSwitchedTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of switched outlets on connected Rack PDUs."
|
|
::= { rPDUOutletSwitched 1 }
|
|
|
|
-- rPDU Switched Outlet Status
|
|
|
|
rPDUOutletSwitchedStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUOutletSwitchedStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU switched outlet status information."
|
|
::= { rPDUOutletSwitched 2 }
|
|
|
|
rPDUOutletSwitchedStatusEntry OBJECT-TYPE
|
|
SYNTAX RPDUOutletSwitchedStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status information for the currently-queried Rack PDU switched
|
|
outlet."
|
|
INDEX { rPDUOutletSwitchedStatusIndex }
|
|
::= { rPDUOutletSwitchedStatusTable 1 }
|
|
|
|
RPDUOutletSwitchedStatusEntry ::=
|
|
SEQUENCE {
|
|
rPDUOutletSwitchedStatusIndex INTEGER,
|
|
rPDUOutletSwitchedStatusNumber INTEGER,
|
|
rPDUOutletSwitchedStatusName DisplayString,
|
|
rPDUOutletSwitchedStatusState INTEGER,
|
|
rPDUOutletSwitchedStatCmdPnding INTEGER,
|
|
rPDUOutletSwitchedStatPhLayout RpduOutletPhaseLayoutType
|
|
}
|
|
|
|
rPDUOutletSwitchedStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU switched outlet status information table
|
|
entry."
|
|
::= { rPDUOutletSwitchedStatusEntry 1 }
|
|
|
|
rPDUOutletSwitchedStatusNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric switched outlet ID."
|
|
::= { rPDUOutletSwitchedStatusEntry 2 }
|
|
|
|
rPDUOutletSwitchedStatusName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined switched outlet ID string."
|
|
::= { rPDUOutletSwitchedStatusEntry 3 }
|
|
|
|
rPDUOutletSwitchedStatusState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on (1),
|
|
off (2),
|
|
unknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the present status of the Rack PDU switched outlet
|
|
being queried."
|
|
::= { rPDUOutletSwitchedStatusEntry 4 }
|
|
|
|
rPDUOutletSwitchedStatCmdPnding OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
commandPending (1),
|
|
noCommandPending (2),
|
|
commandPendingUnknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the device is processing a command for this
|
|
outlet. If the commandPendingUnknown (3) value is returned,
|
|
all devices receiving power from the Rack PDU should be shut down.
|
|
The Rack PDU's power should then be cycled to clear this condition."
|
|
::= { rPDUOutletSwitchedStatusEntry 5 }
|
|
|
|
rPDUOutletSwitchedStatPhLayout OBJECT-TYPE
|
|
SYNTAX RpduOutletPhaseLayoutType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Phase description of the currently-queried Rack PDU switched outlet."
|
|
::= { rPDUOutletSwitchedStatusEntry 6 }
|
|
|
|
-- rPDU Switched Outlet Config
|
|
|
|
rPDUOutletSwitchedConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUOutletSwitchedConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU switched outlet configuration data."
|
|
::= { rPDUOutletSwitched 3 }
|
|
|
|
rPDUOutletSwitchedConfigEntry OBJECT-TYPE
|
|
SYNTAX RPDUOutletSwitchedConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from the currently-queried Rack PDU switched
|
|
outlet."
|
|
INDEX { rPDUOutletSwitchedConfigIndex }
|
|
::= { rPDUOutletSwitchedConfigTable 1 }
|
|
|
|
RPDUOutletSwitchedConfigEntry ::=
|
|
SEQUENCE {
|
|
rPDUOutletSwitchedConfigIndex INTEGER,
|
|
rPDUOutletSwitchedConfigNumber INTEGER,
|
|
rPDUOutletSwitchedConfigName DisplayString,
|
|
rPDUOutSwitchedCfgPowerOnTime INTEGER,
|
|
rPDUOutSwitchedCfgPowerOffTime INTEGER,
|
|
rPDUOutSwtchedCfgRebootDuration INTEGER
|
|
}
|
|
|
|
rPDUOutletSwitchedConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU switched outlet configuration table entry."
|
|
::= { rPDUOutletSwitchedConfigEntry 1 }
|
|
|
|
rPDUOutletSwitchedConfigNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric switched outlet ID."
|
|
::= { rPDUOutletSwitchedConfigEntry 2 }
|
|
|
|
rPDUOutletSwitchedConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined switched outlet ID string."
|
|
::= { rPDUOutletSwitchedConfigEntry 3 }
|
|
|
|
rPDUOutSwitchedCfgPowerOnTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time, in seconds, between when power is provided to
|
|
the Rack PDU and when this switched outlet starts providing power."
|
|
::= { rPDUOutletSwitchedConfigEntry 4 }
|
|
|
|
rPDUOutSwitchedCfgPowerOffTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time, in seconds, this outlet will delay turning off."
|
|
::= { rPDUOutletSwitchedConfigEntry 5 }
|
|
|
|
rPDUOutSwtchedCfgRebootDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"After turning off power during a reboot sequence, the amount of
|
|
time, in seconds, to wait before turning on power to this outlet
|
|
again."
|
|
::= { rPDUOutletSwitchedConfigEntry 6 }
|
|
|
|
-- rPDU Switched Outlet Control
|
|
|
|
rPDUOutletSwitchedControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUOutletSwitchedControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU switched outlet control data."
|
|
::= { rPDUOutletSwitched 4 }
|
|
|
|
rPDUOutletSwitchedControlEntry OBJECT-TYPE
|
|
SYNTAX RPDUOutletSwitchedControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control data for the currently-queried Rack PDU switched outlet."
|
|
INDEX { rPDUOutletSwitchedControlIndex }
|
|
::= { rPDUOutletSwitchedControlTable 1 }
|
|
|
|
RPDUOutletSwitchedControlEntry ::=
|
|
SEQUENCE {
|
|
rPDUOutletSwitchedControlIndex INTEGER,
|
|
rPDUOutletSwitchedControlNumber INTEGER,
|
|
rPDUOutletSwitchedControlName DisplayString,
|
|
rPDUOutletSwitchedControlCmd INTEGER
|
|
}
|
|
|
|
rPDUOutletSwitchedControlIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU switched outlet control data table entry."
|
|
::= { rPDUOutletSwitchedControlEntry 1 }
|
|
|
|
rPDUOutletSwitchedControlNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric switched outlet ID."
|
|
::= { rPDUOutletSwitchedControlEntry 2 }
|
|
|
|
rPDUOutletSwitchedControlName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined switched outlet ID string."
|
|
::= { rPDUOutletSwitchedControlEntry 3 }
|
|
|
|
rPDUOutletSwitchedControlCmd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outletOn (1),
|
|
outletOff (2),
|
|
outletReboot (3),
|
|
outletUnknown (4),
|
|
outletOnWithDelay (5),
|
|
outletOffWithDelay (6),
|
|
outletRebootWithDelay (7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this variable will return the outlet state. If the outlet is
|
|
on, the outletOn (1) value will be returned. If the outlet is off,
|
|
the outletOff (2) value will be returned. If the state of the outlet
|
|
cannot be determined, the outletUnknown (4) value will be returned.
|
|
If the outletUnknown condition should occur, all devices receiving
|
|
power from the PDU should be shut down. The PDU's power should then
|
|
be cycled to clear this condition. Setting this variable to
|
|
outletOn (1) will turn the outlet on. Setting this variable to
|
|
outletOff (2) will turn the outlet off. Setting this variable to
|
|
outletReboot (3) will reboot the outlet. Setting this variable to
|
|
outletOnWithDelay (5) will turn the outlet on after the
|
|
rPDUOutSwitchedCfgPowerOnTime OID has elapsed. Setting this
|
|
variable to outletOffWithDelay (6) will turn the outlet off after
|
|
the rPDUOutSwitchedCfgPowerOffTime OID has elapsed. Setting
|
|
this variable to outletRebootWithDelay (7) will turn the outlet off
|
|
after the rPDUOutSwitchedCfgPowerOffTime OID has elapsed,
|
|
wait the rPDUOutSwtchedCfgRebootDuration OID time, then turn
|
|
the outlet back on."
|
|
::= { rPDUOutletSwitchedControlEntry 4 }
|
|
|
|
rPDUOutletMetered OBJECT IDENTIFIER ::= { rPDUOutlet 2 }
|
|
|
|
-- rPDU Metered Outlet Data
|
|
|
|
rPDUOutletMeteredTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of metered outlets on connected Rack PDUs."
|
|
::= { rPDUOutletMetered 1 }
|
|
|
|
-- rPDU Metered Outlet Status
|
|
|
|
rPDUOutletMeteredStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUOutletMeteredStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU metered outlet status data."
|
|
::= { rPDUOutletMetered 2 }
|
|
|
|
rPDUOutletMeteredStatusEntry OBJECT-TYPE
|
|
SYNTAX RPDUOutletMeteredStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status data from the currently-queried Rack PDU metered outlet."
|
|
INDEX { rPDUOutletMeteredStatusIndex }
|
|
::= { rPDUOutletMeteredStatusTable 1 }
|
|
|
|
RPDUOutletMeteredStatusEntry ::=
|
|
SEQUENCE {
|
|
rPDUOutletMeteredStatusIndex INTEGER,
|
|
rPDUOutletMeteredStatusNumber INTEGER,
|
|
rPDUOutletMeteredStatusName DisplayString,
|
|
rPDUOutletMeteredStatusLayout INTEGER,
|
|
rPDUOutMeteredStatPowerRating INTEGER,
|
|
rPDUOutletMeteredStatusCurrent INTEGER,
|
|
rPDUOutletMeteredStatusEnergy INTEGER,
|
|
rPDUOutletMeteredStatusPower INTEGER,
|
|
rPDUOutletMeteredStatPeakPower INTEGER,
|
|
rPDUOutMeteredStatPeakPwrTime DisplayString,
|
|
rPDUOutMeteredStatusLoadState INTEGER
|
|
}
|
|
|
|
rPDUOutletMeteredStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU metered status table entry."
|
|
::= { rPDUOutletMeteredStatusEntry 1 }
|
|
|
|
rPDUOutletMeteredStatusNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric metered outlet ID."
|
|
::= { rPDUOutletMeteredStatusEntry 2 }
|
|
|
|
rPDUOutletMeteredStatusName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined metered outlet ID string."
|
|
::= { rPDUOutletMeteredStatusEntry 3 }
|
|
|
|
rPDUOutletMeteredStatusLayout OBJECT-TYPE
|
|
SYNTAX RpduOutletPhaseLayoutType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Phase description of currently queried Rack PDU metered outlet."
|
|
::= { rPDUOutletMeteredStatusEntry 4 }
|
|
|
|
rPDUOutMeteredStatPowerRating OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power rating for the currently queried Rack PDU metered outlet."
|
|
::= { rPDUOutletMeteredStatusEntry 5 }
|
|
|
|
rPDUOutletMeteredStatusCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the current draw, in Amps, of the load on the Rack PDU
|
|
outlet being queried."
|
|
::= { rPDUOutletMeteredStatusEntry 6 }
|
|
|
|
rPDUOutletMeteredStatusEnergy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A user resettable energy meter measuring Rack PDU load energy
|
|
consumption in kilowatt-hours."
|
|
::= { rPDUOutletMeteredStatusEntry 7 }
|
|
|
|
rPDUOutletMeteredStatusPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the power draw of the load on the Rack PDU outlet being
|
|
queried."
|
|
::= { rPDUOutletMeteredStatusEntry 8 }
|
|
|
|
rPDUOutletMeteredStatPeakPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The highest power level recorded by the currently queried Rack PDU
|
|
metered outlet, in kilowatts."
|
|
::= { rPDUOutletMeteredStatusEntry 9 }
|
|
|
|
rPDUOutMeteredStatPeakPwrTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the date and time that peak power consumption occured"
|
|
::= { rPDUOutletMeteredStatusEntry 10 }
|
|
|
|
rPDUOutMeteredStatusLoadState OBJECT-TYPE
|
|
SYNTAX RpduLowNormalNearOverloadType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the present load status of the Rack PDU Outlet being
|
|
queried."
|
|
::= { rPDUOutletMeteredStatusEntry 11 }
|
|
|
|
-- rPDU Metered Outlet Config
|
|
|
|
rPDUOutletMeteredConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUOutletMeteredConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of Rack PDU metered outlet configuration data."
|
|
::= { rPDUOutletMetered 4 }
|
|
|
|
rPDUOutletMeteredConfigEntry OBJECT-TYPE
|
|
SYNTAX RPDUOutletMeteredConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from the currently queried Rack PDU metered
|
|
outlet."
|
|
INDEX { rPDUOutletMeteredConfigIndex }
|
|
::= { rPDUOutletMeteredConfigTable 1 }
|
|
|
|
RPDUOutletMeteredConfigEntry ::=
|
|
SEQUENCE {
|
|
rPDUOutletMeteredConfigIndex INTEGER,
|
|
rPDUOutletMeteredConfigNumber INTEGER,
|
|
rPDUOutletMeteredConfigName DisplayString,
|
|
rPDUOutMtredCfgLowLdCurntThresh INTEGER,
|
|
rPDUOutMtrdCfgNrOvdCurntThresh INTEGER,
|
|
rPDUOutMtredCfgOvrldCurntThresh INTEGER
|
|
}
|
|
|
|
rPDUOutletMeteredConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the Rack PDU metered outlet configuration table entry."
|
|
::= { rPDUOutletMeteredConfigEntry 1 }
|
|
|
|
rPDUOutletMeteredConfigNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric switched outlet ID."
|
|
::= { rPDUOutletMeteredConfigEntry 2 }
|
|
|
|
rPDUOutletMeteredConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined metered outlet ID string."
|
|
::= { rPDUOutletMeteredConfigEntry 3 }
|
|
|
|
rPDUOutMtredCfgLowLdCurntThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined low load outlet current threshold, in Amps."
|
|
::= { rPDUOutletMeteredConfigEntry 4 }
|
|
|
|
rPDUOutMtrdCfgNrOvdCurntThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined near outlet overload warning threshold, in Amps."
|
|
::= { rPDUOutletMeteredConfigEntry 5 }
|
|
|
|
rPDUOutMtredCfgOvrldCurntThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined outlet overload current threshold, in Amps."
|
|
::= { rPDUOutletMeteredConfigEntry 6 }
|
|
|
|
rPDUOutMeteredEnergyStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time, in hh:mm:ss, when the currently queried Rack PDU metered
|
|
outlet started recording the input energy level."
|
|
::= { rPDUOutletMetered 5 }
|
|
|
|
rPDUOutMeteredPeakPwrStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time, in hh:mm:ss, when the currently queried Rack PDU metered
|
|
outlet started recording the highest level of input power that is
|
|
available to the connected device."
|
|
::= { rPDUOutletMetered 6 }
|
|
|
|
rPDUPowerSupply OBJECT IDENTIFIER ::= { rPDU 140 }
|
|
|
|
-- the rPDU Power Supply group
|
|
|
|
rPDUPowerSupplyAlarmD OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allAvailablePowerSuppliesOK (1),
|
|
powerSupplyFailed (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Getting this OID will return the status of the power supply alarm."
|
|
::= { rPDUPowerSupply 1 }
|
|
|
|
rPDUPowerSupplyVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The voltage provided by the power supply in tenths of volts."
|
|
::= { rPDUPowerSupply 2 }
|
|
|
|
rPDUSensor OBJECT IDENTIFIER ::= { rPDU 150 }
|
|
|
|
-- rPDU Sensor Data
|
|
|
|
rPDUSensorStatus OBJECT IDENTIFIER ::= { rPDUSensor 1 }
|
|
|
|
-- rPDU Sensor Status Data
|
|
|
|
rPDUSensorStatusTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of connected temperature sensors."
|
|
::= { rPDUSensorStatus 1 }
|
|
|
|
-- rPDU Temperature Sensor Status
|
|
|
|
rPDUSensorStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUSensorStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of temperature sensor status data."
|
|
::= { rPDUSensorStatus 2 }
|
|
|
|
rPDUSensorStatusEntry OBJECT-TYPE
|
|
SYNTAX RPDUSensorStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status information from the temperature sensor being queried."
|
|
INDEX { rPDUSensorStatusIndex }
|
|
::= { rPDUSensorStatusTable 1 }
|
|
|
|
RPDUSensorStatusEntry ::=
|
|
SEQUENCE {
|
|
rPDUSensorStatusIndex INTEGER,
|
|
rPDUSensorStatusName DisplayString,
|
|
rPDUSensorStatusType INTEGER
|
|
}
|
|
|
|
rPDUSensorStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the status data table entry."
|
|
::= { rPDUSensorStatusEntry 1 }
|
|
|
|
rPDUSensorStatusName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined sensor ID string."
|
|
::= { rPDUSensorStatusEntry 2 }
|
|
|
|
rPDUSensorStatusType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
temperature (2),
|
|
temperatureHumidity (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of the sensor."
|
|
::= { rPDUSensorStatusEntry 3 }
|
|
|
|
rPDUSensorTemp OBJECT IDENTIFIER ::= { rPDUSensor 2 }
|
|
|
|
-- rPDU Temperature Sensor Data
|
|
|
|
rPDUSensorTempTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of connected temperature sensors."
|
|
::= { rPDUSensorTemp 1 }
|
|
|
|
-- rPDU Temperature Sensor Status
|
|
|
|
rPDUSensorTempStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUSensorTempStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of temperature sensor status data."
|
|
::= { rPDUSensorTemp 2 }
|
|
|
|
rPDUSensorTempStatusEntry OBJECT-TYPE
|
|
SYNTAX RPDUSensorTempStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status information from the temperature sensor being queried."
|
|
INDEX { rPDUSensorTempStatusIndex }
|
|
::= { rPDUSensorTempStatusTable 1 }
|
|
|
|
RPDUSensorTempStatusEntry ::=
|
|
SEQUENCE {
|
|
rPDUSensorTempStatusIndex INTEGER,
|
|
rPDUSensorTempStatusName DisplayString,
|
|
rPDUSensorTempStatusCommStatus INTEGER,
|
|
rPDUSensorTempStatusTempF INTEGER,
|
|
rPDUSensorTempStatusTempC INTEGER,
|
|
rPDUSensorTempStatusAlarmStatus INTEGER
|
|
}
|
|
|
|
rPDUSensorTempStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the temperature status data table entry."
|
|
::= { rPDUSensorTempStatusEntry 1 }
|
|
|
|
rPDUSensorTempStatusName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined temperature-humidity sensor ID string."
|
|
::= { rPDUSensorTempStatusEntry 2 }
|
|
|
|
rPDUSensorTempStatusCommStatus OBJECT-TYPE
|
|
SYNTAX RpduCommNoneOKLostType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The communications status of the sensor."
|
|
::= { rPDUSensorTempStatusEntry 3 }
|
|
|
|
rPDUSensorTempStatusTempF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor temperature reading in tenths of degrees Fahrenheit."
|
|
::= { rPDUSensorTempStatusEntry 4 }
|
|
|
|
rPDUSensorTempStatusTempC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor temperature reading in tenths of degrees Celsius."
|
|
::= { rPDUSensorTempStatusEntry 5 }
|
|
|
|
rPDUSensorTempStatusAlarmStatus OBJECT-TYPE
|
|
SYNTAX RpduNotPBMinLowNrmlOHiMaxType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The alarm status of the sensor."
|
|
::= { rPDUSensorTempStatusEntry 6 }
|
|
|
|
-- rPDU Temperature Sensor Config
|
|
|
|
rPDUSensorTempConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUSensorTempConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of temperature-humidity sensor configuration data."
|
|
::= { rPDUSensorTemp 3 }
|
|
|
|
rPDUSensorTempConfigEntry OBJECT-TYPE
|
|
SYNTAX RPDUSensorTempConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from the temperature-humidity sensor being
|
|
queried."
|
|
INDEX { rPDUSensorTempConfigIndex }
|
|
::= { rPDUSensorTempConfigTable 1 }
|
|
|
|
RPDUSensorTempConfigEntry ::=
|
|
SEQUENCE {
|
|
rPDUSensorTempConfigIndex INTEGER,
|
|
rPDUSensorTempConfigName DisplayString,
|
|
rPDUSensorTempCfgTempMaxThreshF INTEGER,
|
|
rPDUSnsorTempCfgTempHighThreshF INTEGER,
|
|
rPDUSnsorTempCfgTempHysteresisF INTEGER,
|
|
rPDUSensorTempCfgTempMaxThreshC INTEGER,
|
|
rPDUSnsorTempCfgTempHighThreshC INTEGER,
|
|
rPDUSnsorTempCfgTempHysteresisC INTEGER,
|
|
rPDUSnsorTempCfgAlarmGeneration INTEGER
|
|
}
|
|
|
|
rPDUSensorTempConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the temperature-humidity sensor configuration data
|
|
table entry."
|
|
::= { rPDUSensorTempConfigEntry 1 }
|
|
|
|
rPDUSensorTempConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined temperature-humidity sensor ID string."
|
|
::= { rPDUSensorTempConfigEntry 2 }
|
|
|
|
rPDUSensorTempCfgTempMaxThreshF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor maximum temperature alarm threshold in Fahrenheit."
|
|
::= { rPDUSensorTempConfigEntry 3 }
|
|
|
|
rPDUSnsorTempCfgTempHighThreshF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor high temperature warning alarm threshold in Fahrenheit."
|
|
::= { rPDUSensorTempConfigEntry 4 }
|
|
|
|
rPDUSnsorTempCfgTempHysteresisF OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor temperature hysteresis setting in Fahrenheit."
|
|
::= { rPDUSensorTempConfigEntry 5 }
|
|
|
|
rPDUSensorTempCfgTempMaxThreshC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor maximum temperature alarm threshold in Celsius."
|
|
::= { rPDUSensorTempConfigEntry 6 }
|
|
|
|
rPDUSnsorTempCfgTempHighThreshC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor high temperature warning alarm threshold in Celsius."
|
|
::= { rPDUSensorTempConfigEntry 7 }
|
|
|
|
rPDUSnsorTempCfgTempHysteresisC OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor temperature hysteresis setting in Celsius."
|
|
::= { rPDUSensorTempConfigEntry 8 }
|
|
|
|
rPDUSnsorTempCfgAlarmGeneration OBJECT-TYPE
|
|
SYNTAX RpduEnableDisableType
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the Temp Alarm Generation is enabled."
|
|
::= { rPDUSensorTempConfigEntry 9 }
|
|
|
|
rPDUSensorHumidity OBJECT IDENTIFIER ::= { rPDUSensor 3 }
|
|
|
|
-- rPDU Humidity Sensor
|
|
|
|
rPDUSensorHumidityTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of connected temperature-humidity sensors."
|
|
::= { rPDUSensorHumidity 1 }
|
|
|
|
-- rPDU Humidity Sensor Status
|
|
|
|
rPDUSensorHumidityStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUSensorHumidityStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of temperature-humidity sensor status data."
|
|
::= { rPDUSensorHumidity 2 }
|
|
|
|
rPDUSensorHumidityStatusEntry OBJECT-TYPE
|
|
SYNTAX RPDUSensorHumidityStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status information from the temperature-humidity sensor being
|
|
queried."
|
|
INDEX { rPDUSensorHumidityStatusIndex }
|
|
::= { rPDUSensorHumidityStatusTable 1 }
|
|
|
|
RPDUSensorHumidityStatusEntry ::=
|
|
SEQUENCE {
|
|
rPDUSensorHumidityStatusIndex INTEGER,
|
|
rPDUSensorHumidityStatusName DisplayString,
|
|
rPDUSnsorHumidityStatCommStatus INTEGER,
|
|
rPDUSnsorHumStatRelativeHumdity INTEGER,
|
|
rPDUSnsorHumStatusAlarmStatus INTEGER
|
|
}
|
|
|
|
rPDUSensorHumidityStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the temperature-humidity status data table entry."
|
|
::= { rPDUSensorHumidityStatusEntry 1 }
|
|
|
|
rPDUSensorHumidityStatusName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined temperature-humidity sensor ID string."
|
|
::= { rPDUSensorHumidityStatusEntry 2 }
|
|
|
|
rPDUSnsorHumidityStatCommStatus OBJECT-TYPE
|
|
SYNTAX RpduCommNoneOKLostType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The communications status of the sensor."
|
|
::= { rPDUSensorHumidityStatusEntry 3 }
|
|
|
|
rPDUSnsorHumStatRelativeHumdity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor humidity reading in percent relative humidity."
|
|
::= { rPDUSensorHumidityStatusEntry 4 }
|
|
|
|
rPDUSnsorHumStatusAlarmStatus OBJECT-TYPE
|
|
SYNTAX RpduNotPBMinLowNrmlOHiMaxType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The alarm status of the sensor."
|
|
::= { rPDUSensorHumidityStatusEntry 5 }
|
|
|
|
-- rPDU Humidity Sensor Config
|
|
|
|
rPDUSensorHumidityConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUSensorHumidityConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of temperature-humidity sensor configuration data."
|
|
::= { rPDUSensorHumidity 3 }
|
|
|
|
rPDUSensorHumidityConfigEntry OBJECT-TYPE
|
|
SYNTAX RPDUSensorHumidityConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from the temperature-humidity sensor being
|
|
queried."
|
|
INDEX { rPDUSensorHumidityConfigIndex }
|
|
::= { rPDUSensorHumidityConfigTable 1 }
|
|
|
|
RPDUSensorHumidityConfigEntry ::=
|
|
SEQUENCE {
|
|
rPDUSensorHumidityConfigIndex INTEGER,
|
|
rPDUSensorHumidityConfigName DisplayString,
|
|
rPDUSnsorHumCfgHumdityLowThresh INTEGER,
|
|
rPDUSnsorHumCfgHumdityMinThresh INTEGER,
|
|
rPDUSnsorHumCfgHumdtyHysteresis INTEGER,
|
|
rPDUSnsorHumCfgAlarmGeneration INTEGER
|
|
}
|
|
|
|
rPDUSensorHumidityConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the temperature-humidity sensor configuration data
|
|
table entry."
|
|
::= { rPDUSensorHumidityConfigEntry 1 }
|
|
|
|
rPDUSensorHumidityConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined temperature-humidity sensor ID string."
|
|
::= { rPDUSensorHumidityConfigEntry 2 }
|
|
|
|
rPDUSnsorHumCfgHumdityLowThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor low humidity warning alarm threshold in percent relative
|
|
humidity."
|
|
::= { rPDUSensorHumidityConfigEntry 3 }
|
|
|
|
rPDUSnsorHumCfgHumdityMinThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor minimum humidity alarm threshold in percent relative
|
|
humidity."
|
|
::= { rPDUSensorHumidityConfigEntry 4 }
|
|
|
|
rPDUSnsorHumCfgHumdtyHysteresis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor humidity hysteresis setting in percent relative humidity."
|
|
::= { rPDUSensorHumidityConfigEntry 5 }
|
|
|
|
rPDUSnsorHumCfgAlarmGeneration OBJECT-TYPE
|
|
SYNTAX RpduEnableDisableType
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the Humidity Alarm Generation is enabled."
|
|
::= { rPDUSensorHumidityConfigEntry 6 }
|
|
|
|
rPDUSensorDiscrete OBJECT IDENTIFIER ::= { rPDUSensor 4 }
|
|
|
|
-- rPDU Discrete Sensor Data
|
|
|
|
rPDUSensorDiscreteTableSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of connected discrete sensors."
|
|
::= { rPDUSensorDiscrete 1 }
|
|
|
|
-- rPDU Discrete Sensor Status
|
|
|
|
rPDUSensorDiscreteStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUSensorDiscreteStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of discrete sensor status data."
|
|
::= { rPDUSensorDiscrete 2 }
|
|
|
|
rPDUSensorDiscreteStatusEntry OBJECT-TYPE
|
|
SYNTAX RPDUSensorDiscreteStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status information from the discrete sensor being queried."
|
|
INDEX { rPDUSensorDiscreteStatusIndex }
|
|
::= { rPDUSensorDiscreteStatusTable 1 }
|
|
|
|
RPDUSensorDiscreteStatusEntry ::=
|
|
SEQUENCE {
|
|
rPDUSensorDiscreteStatusIndex INTEGER,
|
|
rPDUSensorDiscreteStatusName DisplayString,
|
|
rPDUSnsorDiscreteStatCurntState INTEGER,
|
|
rPDUSnsorDiscreteStatAlarmState INTEGER
|
|
}
|
|
|
|
rPDUSensorDiscreteStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the discrete sensor status data table entry."
|
|
::= { rPDUSensorDiscreteStatusEntry 1 }
|
|
|
|
rPDUSensorDiscreteStatusName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined discrete sensor ID string."
|
|
::= { rPDUSensorDiscreteStatusEntry 2 }
|
|
|
|
rPDUSnsorDiscreteStatCurntState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2),
|
|
unknown (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current state of the discrete sensor, open, closed, or unknown."
|
|
::= { rPDUSensorDiscreteStatusEntry 3 }
|
|
|
|
rPDUSnsorDiscreteStatAlarmState OBJECT-TYPE
|
|
SYNTAX RpduNormalAlarmType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the alarm status of the discrete sensor input."
|
|
::= { rPDUSensorDiscreteStatusEntry 4 }
|
|
|
|
-- rPDU Discrete Sensor Config
|
|
|
|
rPDUSensorDiscreteConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RPDUSensorDiscreteConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of discrete sensor configuration data."
|
|
::= { rPDUSensorDiscrete 3 }
|
|
|
|
rPDUSensorDiscreteConfigEntry OBJECT-TYPE
|
|
SYNTAX RPDUSensorDiscreteConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration data from the discrete sensor being queried."
|
|
INDEX { rPDUSensorDiscreteConfigIndex }
|
|
::= { rPDUSensorDiscreteConfigTable 1 }
|
|
|
|
RPDUSensorDiscreteConfigEntry ::=
|
|
SEQUENCE {
|
|
rPDUSensorDiscreteConfigIndex INTEGER,
|
|
rPDUSensorDiscreteConfigName DisplayString,
|
|
rPDUSnsorDiscreteCfgNormalState INTEGER,
|
|
rPDUSnsorDiscrteAlarmGeneration INTEGER
|
|
}
|
|
|
|
rPDUSensorDiscreteConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index to the discrete sensor configuration data table entry."
|
|
::= { rPDUSensorDiscreteConfigEntry 1 }
|
|
|
|
rPDUSensorDiscreteConfigName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined discrete sensor ID string."
|
|
::= { rPDUSensorDiscreteConfigEntry 2 }
|
|
|
|
rPDUSnsorDiscreteCfgNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
open (1),
|
|
closed (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the normal state of the discrete input contact."
|
|
::= { rPDUSensorDiscreteConfigEntry 3 }
|
|
|
|
rPDUSnsorDiscrteAlarmGeneration OBJECT-TYPE
|
|
SYNTAX RpduEnableDisableType
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether Discrete Alarm Generation is enabled."
|
|
::= { rPDUSensorDiscreteConfigEntry 4 }
|
|
|
|
mtrapargsD OBJECT IDENTIFIER ::= { rPDU 160 }
|
|
|
|
-- The mtrapargsD group
|
|
-- These OIDs allows traps to be sent with additional arguments
|
|
-- which may not be defined in the MIB.
|
|
|
|
contactNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows traps to be sent with an integer argument that
|
|
may not be defined in the MIB. A get of this OID will return 0."
|
|
::= { mtrapargsD 1 }
|
|
|
|
outletNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows traps to be sent with an integer argument that
|
|
may not be defined in the MIB. A get of this OID will return 0."
|
|
::= { mtrapargsD 2 }
|
|
|
|
mtrapargsString OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows traps to be sent with an octet string argument
|
|
that may not be defined in the MIB. A get of this OID will return
|
|
a NULL string."
|
|
::= { mtrapargsD 3 }
|
|
|
|
phaseNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows traps to be sent with an integer argument that
|
|
may not be defined in the MIB. A get of this OID will return 0."
|
|
::= { mtrapargsD 4 }
|
|
|
|
sensorNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows traps to be sent with an integer argument that
|
|
may not be defined in the MIB. A get of this OID will return 0."
|
|
::= { mtrapargsD 5 }
|
|
|
|
deviceNameD OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows traps to be sent with an octet string argument
|
|
that may not be defined in the MIB. A get of this OID will return
|
|
a NULL string."
|
|
::= { mtrapargsD 6 }
|
|
|
|
serialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows traps to be sent with an octet string argument that
|
|
may not be defined in the MIB. A get of this OID will return a NULL
|
|
string."
|
|
::= { mtrapargsD 7 }
|
|
|
|
testTrapargsInteger OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This OID allows traps to be sent with an integer argument that
|
|
may not be defined in the MIB. A get of this OID will return 0."
|
|
::= { mtrapargsD 8 }
|
|
|
|
events OBJECT IDENTIFIER ::= { rPDU 500 }
|
|
|
|
-- Traps
|
|
-- Annotations are provided for Novell's NMS product
|
|
--
|
|
-- Each trap has at least one variable (mtrapargsString) which always
|
|
-- appears as the last variable in the list. This variable contains either
|
|
-- a static or dynamically-constructed string which provides an enhanced
|
|
-- description of the trap's purpose and any pertinent information about
|
|
-- the trap.
|
|
|
|
deviceCommunicationLostCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Lost communication with device
|
|
has been re-established.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s lost communication with device has been re-established."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 1
|
|
|
|
deviceCommunicationLostSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"CRITICAL: Lost communication with device.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s lost communication with device."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY CRITICAL
|
|
::= 2
|
|
|
|
componentCommLostCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Lost communication with an on board component
|
|
has been re-established.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s comm with on board component was re-established."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 3
|
|
|
|
componentCommLostSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"CRITICAL: Lost communication with an on board component.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s lost communication with an on board component."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY CRITICAL
|
|
::= 4
|
|
|
|
cANBusOffCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: CAN bus off condition was cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s CAN bus off was cleared."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 5
|
|
|
|
canBusOffSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"MINOR: CAN bus off condition was set.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s CAN bus off was set."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY MINOR
|
|
::= 6
|
|
|
|
powerSupplyFailureCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Unit's power supply voltage is no longer out of
|
|
tolerance.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s unit's power supply voltage is no longer out of tolerance."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 7
|
|
|
|
powerSupplyFailureSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"CRITICAL: Unit's power supply voltage is out of tolerance.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s unit's power supply voltage is out of tolerance."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY CRITICAL
|
|
::= 8
|
|
|
|
keypadButtonStuckCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Keypad button stuck has been cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s keypad button no longer stuck."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 9
|
|
|
|
keypadButtonStuckSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"MINOR: Keypad button stuck has been set.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s keypad button stuck."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY MINOR
|
|
::= 10
|
|
|
|
dryContactAbnormalCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, contactNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Dry Contact is no longer in an abnormal state.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the contact number."
|
|
--#SUMMARY "%s dry contact #%s is no longer in an abnormal state."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 11
|
|
|
|
dryContactAbnormalSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, contactNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"CRITICAL: Dry Contact has moved to an abnormal state.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the contact number."
|
|
--#SUMMARY "%s dry contact #%s has moved to an abnormal state."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY CRITICAL
|
|
::= 12
|
|
|
|
deviceLowLoadCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Device load is no longer below the 'Low Load'
|
|
threshold value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s device is no longer below the 'Low Load' threshold."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 13
|
|
|
|
deviceLowLoadSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"MINOR: Device load has fallen below the 'Low Load' threshold
|
|
value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s Device load has fallen below the 'Low Load' threshold."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY MINOR
|
|
::= 14
|
|
|
|
deviceNearOverLoadCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Device load no longer exceeds the 'Near Over Load'
|
|
threshold value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s device not over 'Near Over Load' threshold."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 15
|
|
|
|
deviceNearOverLoadSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"MINOR: Device load has exceeded the 'Near Over Load' threshold
|
|
value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s device is over the 'Near Over Load' threshold."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY MINOR
|
|
::= 16
|
|
|
|
deviceOverLoadCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Device load no longer exceeds the 'Over Load'
|
|
threshold value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s device not over the 'Over Load' threshold."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 17
|
|
|
|
deviceOverLoadSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"CRITICAL: Device load has exceeded the 'Over Load' threshold
|
|
value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s device load is over the 'Over Load' threshold."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY CRITICAL
|
|
::= 18
|
|
|
|
phaseLowLoadCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, phaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Phase load is no longer below the 'Low Load'
|
|
threshold value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#SUMMARY "%s phase #%s load is no longer below 'Low Load' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 19
|
|
|
|
phaseLowLoadSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, phaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"MINOR: Phase load has fallen below the 'Low Load' threshold
|
|
value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#SUMMARY "%s phase #%s load has fallen below the 'Low Load' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY MINOR
|
|
::= 20
|
|
|
|
phaseNearOverLoadCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, phaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Phase load no longer exceeds the 'Near Over Load'
|
|
threshold value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#SUMMARY "%s phase #%s load not over 'Near Over Load' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 21
|
|
|
|
phaseNearOverLoadSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, phaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"MINOR: Phase load has exceeded the 'Near Over Load' threshold
|
|
value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#SUMMARY "%s phase #%s load is over the 'Near Over Load' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY MINOR
|
|
::= 22
|
|
|
|
phaseOverLoadCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, phaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Phase load no longer exceeds the 'Over Load'
|
|
threshold value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#SUMMARY "%s phase #%s load not over the 'Over Load' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 23
|
|
|
|
phaseOverLoadSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, phaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"CRITICAL: Phase load has exceeded the 'Over Load' threshold
|
|
value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#SUMMARY "%s phase #%s load is over the 'Over Load' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY CRITICAL
|
|
::= 24
|
|
|
|
outletLowLoadCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Outlet load is no longer below the 'Low Load'
|
|
threshold value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#SUMMARY "%s outlet #%s load is not below the 'Low Load' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 25
|
|
|
|
outletLowLoadSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"MINOR: Outlet load had fallen below the 'Low Load' threshold
|
|
value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#SUMMARY "%s outlet #%s load has fallen below the 'Low Load' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY MINOR
|
|
::= 26
|
|
|
|
outletNearOverLoadCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Outlet load no longer exceeds the 'Near Over Load'
|
|
threshold value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#SUMMARY "%s outlet #%s load not over 'Near Over Load' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 27
|
|
|
|
outletNearOverLoadSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"MINOR: Outlet load has exceeded the 'Near Over Load' threshold
|
|
value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#SUMMARY "%s outlet #%s load is over 'Near Over Load' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY MINOR
|
|
::= 28
|
|
|
|
outletOverLoadCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Outlet load no longer exceeds the 'Over Load'
|
|
threshold value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#SUMMARY "%s outlet #%s load not over the 'Over Load' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 29
|
|
|
|
outletOverLoadSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"CRITICAL: Outlet load has exceeded the 'Over Load' threshold
|
|
value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#SUMMARY "%s outlet #%s load is over the 'Over Load' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY CRITICAL
|
|
::= 30
|
|
|
|
sensorDisconnectedCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Sensor disconnected condition cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the sensor number."
|
|
--#SUMMARY "%s sensor #%s disconnected condition cleared."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 31
|
|
|
|
sensorDisconnectedSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"MINOR: Sensor disconnected condition set.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the sensor number."
|
|
--#SUMMARY "%s sensor #%s disconnected condition set."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY MINOR
|
|
::= 32
|
|
|
|
sensorTypeIndeterminateCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Sensor type indeterminate condition cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the sensor number."
|
|
--#SUMMARY "%s sensor #%s type indeterminate condition cleared."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 33
|
|
|
|
sensorTypeIndeterminateSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"MINOR: Sensor type indeterminate condition set.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the sensor number."
|
|
--#SUMMARY "%s sensor #%s type indeterminate condition set."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY MINOR
|
|
::= 34
|
|
|
|
sensorTypeUnsupportedCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Sensor type unsupported condition cleared.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the sensor number."
|
|
--#SUMMARY "%s sensor #%s type unsupported condition cleared."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 35
|
|
|
|
sensorTypeUnsupportedSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"MINOR: Sensor type unsupported condition set.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the sensor number."
|
|
--#SUMMARY "%s sensor #%s type unsupported condition set."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY MINOR
|
|
::= 36
|
|
|
|
maxTemperatureExceededCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Sensor Temperature no longer exceeds the
|
|
'Max Temperature' threshold value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the sensor number."
|
|
--#SUMMARY "%s sensor #%s temp not over 'Max Temperature' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 37
|
|
|
|
maxTemperatureExceededSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"CRITICAL: Sensor Temperature has exceeded the 'Max Temperature'
|
|
threshold value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the sensor number."
|
|
--#SUMMARY "%s sensor #%s temp is over 'Max Temperature' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY CRITICAL
|
|
::= 38
|
|
|
|
highTemperatureExceededCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Sensor Temperature no longer exceeds the 'High
|
|
Temperature' threshold value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the sensor number."
|
|
--#SUMMARY "%s sensor #%s temp below 'High Temperature' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 39
|
|
|
|
highTemperatureExceededSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"MINOR: Sensor Temperature has exceeded the 'High Temperature'
|
|
threshold value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the sensor number."
|
|
--#SUMMARY "%s sensor #%s temp over 'High Temperature' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY MINOR
|
|
::= 40
|
|
|
|
lowHumidityExceededCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Sensor Humidity is no longer below the 'Low
|
|
Humidity' threshold value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the sensor number."
|
|
--#SUMMARY "%s sensor #%s humidity is above 'Low Humidity' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 41
|
|
|
|
lowHumidityExceededSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"MINOR: Sensor Humidity has fallen below the 'Low Humidity'
|
|
threshold value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the sensor number."
|
|
--#SUMMARY "%s sensor #%s humidity is below 'Low Humidity' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY MINOR
|
|
::= 42
|
|
|
|
minHumidityExceededCleared TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Sensor Humidity is no longer below the 'Min
|
|
Humidity' threshold value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the sensor number."
|
|
--#SUMMARY "%s sensor #%s humidity is above 'Min Humidity' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 43
|
|
|
|
minHumidityExceededSet TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"CRITICAL: Sensor Humidity has fallen below the 'Min Humidity'
|
|
threshold value.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the sensor number."
|
|
--#SUMMARY "%s sensor #%s humidity is below 'Min Humidity' threshold."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY CRITICAL
|
|
::= 44
|
|
|
|
outletTurnOn TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet has turned on.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#SUMMARY "%s outlet #%s has turned on."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 45
|
|
|
|
outletTurnOff TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet has turned off.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#SUMMARY "%s outlet #%s has turned off."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 46
|
|
|
|
actionCancelled TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet action has been cancelled.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#SUMMARY "%s outlet #%s action has been cancelled."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 47
|
|
|
|
deviceConfigurationChange TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A device configuration has been changed.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s device configuration has been changed."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 48
|
|
|
|
sensorConfigurationChange TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A sensor configuration has been changed.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the sensor number."
|
|
--#SUMMARY "%s sensor #%s configuration has been changed."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 49
|
|
|
|
outletConfigurationChange TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet configuration has been changed.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#SUMMARY "%s outlet #%s configuration has been changed."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 50
|
|
|
|
phaseConfigurationChange TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, phaseNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A phase configuration has been changed.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the phase number."
|
|
--#SUMMARY "%s phase #%s configuration has been changed."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 51
|
|
|
|
dryContactConfigurationChange TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, contactNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: A dry contact configuration has been changed.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the contact number."
|
|
--#SUMMARY "%s dry contact #%s configuration has been changed."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 52
|
|
|
|
actionInit TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet action has been initialized.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#SUMMARY "%s outlet #%s action has been initialized."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 53
|
|
|
|
actionFailed TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"MINOR: An outlet action has failed to complete.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#SUMMARY "%s outlet #%s action has failed to complete."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY MINOR
|
|
::= 54
|
|
|
|
actionDeleted TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: An outlet action has been deleted.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#SUMMARY "%s outlet #%s action has been deleted."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 55
|
|
|
|
syncCommandFailed TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"MINOR: An outlet sync command to another unit has failed.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the outlet number."
|
|
--#SUMMARY "%s outlet #%s sync command to another unit has failed."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY MINOR
|
|
::= 56
|
|
|
|
mPOPicFwDownloadStarted TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: MPO pic fw download started.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s MPO pic fw download started."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 57
|
|
|
|
mPOPicFwDownloadComplete TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: MPO pic fw download complete.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s MPO pic fw download complete."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 58
|
|
|
|
mPOPicFwDownloadAborted TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: MPO pic fw download aborted.
|
|
The first argument is the serial number.
|
|
The second argument is the device name."
|
|
--#SUMMARY "%s MPO pic fw download aborted."
|
|
--#ARGUMENTS {1}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 59
|
|
|
|
sensorCommEstablished TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Sensor comm established.
|
|
The first argument is the serial number.
|
|
The second argument is the device name.
|
|
The third argument is the sensor number."
|
|
--#SUMMARY "%s sensor #%s comm established."
|
|
--#ARGUMENTS {1,2}
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 60
|
|
|
|
-- System generated traps
|
|
|
|
configChangeSNMP TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"MINOR: The SNMP configuration has been changed."
|
|
--#SUMMARY "The SNMP configuration has been changed."
|
|
--#SEVERITY MINOR
|
|
::= 1000
|
|
|
|
accessViolationConsole TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"MINOR: Someone attempted console login with incorrect password
|
|
three times."
|
|
--#SUMMARY "Three unsuccessful logins were attempted via the console."
|
|
--#SEVERITY MINOR
|
|
::= 1001
|
|
|
|
accessViolationHTTP TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { mtrapargsString }
|
|
DESCRIPTION
|
|
"MINOR: Someone attempted login via HTTP with incorrect password."
|
|
--#SUMMARY "An unsuccessful attempt to login via HTTP."
|
|
--#SEVERITY MINOR
|
|
::= 1002
|
|
|
|
dellTestTrap TRAP-TYPE
|
|
ENTERPRISE events
|
|
VARIABLES { testTrapargsInteger, mtrapargsString }
|
|
DESCRIPTION
|
|
"INFORMATIONAL: Trap used to test SNMP trap functionality.
|
|
The first argument is a place holder for test variables."
|
|
--#SUMMARY "Test Trap."
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 1003
|
|
|
|
END
|
|
|