mibs/MIBS/dell/DellrPDU-MIB
2023-12-05 12:25:34 +01:00

2943 lines
89 KiB
Plaintext

--
-- 12/23/2009 - v1.0r Dell rPDU
--
-- **********************************************************************
-- **********************************************************************
-- dellrPDU-MIB { iso org(3) dod(6) internet(1) private(4) enterprises(1)
-- dell(674) }
DellrPDU-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, IpAddress, Gauge, TimeTicks FROM RFC1155-SMI
DisplayString FROM RFC1213-MIB
OBJECT-TYPE FROM RFC-1212
TRAP-TYPE FROM RFC-1215;
dell OBJECT IDENTIFIER ::= { enterprises 674 }
pdu OBJECT IDENTIFIER ::= { dell 10903 }
pdusub OBJECT IDENTIFIER ::= { pdu 200 }
-- 1.3.6.1.4.1.674.10903.200
software OBJECT IDENTIFIER ::= { pdusub 1 }
hardware OBJECT IDENTIFIER ::= { pdusub 2 }
system OBJECT IDENTIFIER ::= { pdusub 3 }
sysRPDUV1 OBJECT IDENTIFIER ::= { system 1 }
-- Common rPDU values
RpduEnableDisableType ::= INTEGER {
disabled (1),
enabled (2)
}
RpduNormalAlarmType ::= INTEGER {
normal (1),
alarm (2)
}
RpduCommNoneOKLostType ::= INTEGER {
notInstalled (1),
commsOK (2),
commsLost (3)
}
RpduLowNormalNearOverloadType ::= INTEGER {
lowLoad (1),
normal (2),
nearOverload (3),
overload (4)
}
RpduNotPBMinLowNrmlOHiMaxType ::= INTEGER {
notPresent (1),
belowMin (2),
belowLow (3),
normal (4),
overHigh (5),
overMax (6)
}
RpduOtherToNonrecoverableType ::= INTEGER {
other (1),
unknown (2),
ok (3),
non-critical (4),
critical (5),
non-recoverable (6)
}
RpduOutletPhaseLayoutType ::= INTEGER {
seqPhase1ToNeutral (1),
seqPhase2ToNeutral (2),
seqPhase3ToNeutral (3),
seqPhase1ToPhase2 (4),
seqPhase2ToPhase3 (5),
seqPhase3ToPhase1 (6)
}
productID OBJECT IDENTIFIER ::= { hardware 100 }
productIDDisplayName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of this product for display purposes."
::= { productID 1 }
productIDDescription OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A short description of this product."
::= { productID 2 }
productIDVendor OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of the product manufacturer."
::= { productID 3 }
productIDVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The hardware version of this product."
::= { productID 4 }
productIDBuildNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The software build number of the product populating the MIB."
::= { productID 5 }
productIDURL OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The URL of the Web-based application to manage this device, should
the device provide one."
::= { productID 6 }
productIDDeviceNetworkName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Operating system-specific computer name if product SNMP service is
hosted."
::= { productID 7 }
productStatus OBJECT IDENTIFIER ::= { hardware 110 }
productStatusGlobalStatus OBJECT-TYPE
SYNTAX RpduOtherToNonrecoverableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current status of the product. This is a summary of the status
for the entire product including any metered devices. The SNMP
monitor performs a get to retrieve additional data when this status
is abnormal. Valid values 1: Other 2: Unknown 3: OK 4: Non-critical
5: Critical 6: Non-recoverable."
::= { productStatus 1 }
productStatusLastGlobalStatus OBJECT-TYPE
SYNTAX RpduOtherToNonrecoverableType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status before the current status which induced an initiative to
issue a global status change trap."
::= { productStatus 2 }
productStatusTimeStamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The last time that the SNMP table geometries changed or attribute
data was significantly updated. Management applications use this OID
to trigger a refresh of data acquired from the MIB. This time should
be a relative timestamp, for example, the value of MIB II SysUpTime
when the values are updated."
::= { productStatus 3 }
productStatusRESERVED1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RESERVED"
::= { productStatus 4 }
productStatusRESERVED2 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RESERVED"
::= { productStatus 5 }
productStatusRESERVED3 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RESERVED"
::= { productStatus 6 }
rPDU OBJECT IDENTIFIER ::= { hardware 200 }
rPDUIdentD OBJECT IDENTIFIER ::= { rPDU 100 }
-- rPDU Ident Table
rPDUIdentTableSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of connected Rack PDUs."
::= { rPDUIdentD 1 }
rPDUIdentTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUIdentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of Rack PDU identification data."
::= { rPDUIdentD 2 }
rPDUIdentEntry OBJECT-TYPE
SYNTAX RPDUIdentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Identification data from the Rack PDU being queried."
INDEX { rPDUIdentIndex }
::= { rPDUIdentTable 1 }
RPDUIdentEntry ::=
SEQUENCE {
rPDUIdentIndex INTEGER,
rPDUIdentNameD DisplayString,
rPDUIdentLocation DisplayString,
rPDUIdentHardwareRevD DisplayString,
rPDUIdentFirmwareRevD DisplayString,
rPDUIdentDateOfManufactureD DisplayString,
rPDUIdentModelNumberD DisplayString,
rPDUIdentSerialNumberD DisplayString
}
rPDUIdentIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the Rack PDU identification table entry."
::= { rPDUIdentEntry 1 }
rPDUIdentNameD OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A user-defined string identifying the Rack PDU."
::= { rPDUIdentEntry 2 }
rPDUIdentLocation OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A user-defined string identifying the location of the Rack PDU."
::= { rPDUIdentEntry 3 }
rPDUIdentHardwareRevD OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Rack PDU hardware version."
::= { rPDUIdentEntry 4 }
rPDUIdentFirmwareRevD OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Rack PDU firmware version."
::= { rPDUIdentEntry 5 }
rPDUIdentDateOfManufactureD OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date the Rack PDU was manufactured in mm/dd/yyyy format."
::= { rPDUIdentEntry 6 }
rPDUIdentModelNumberD OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Rack PDU model number."
::= { rPDUIdentEntry 7 }
rPDUIdentSerialNumberD OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Rack PDU serial number."
::= { rPDUIdentEntry 8 }
rPDUDevice OBJECT IDENTIFIER ::= { rPDU 110 }
-- rPDU Device Data
rPDUDeviceTableSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of connected Rack PDUs."
::= { rPDUDevice 1 }
-- rPDU Device Status
rPDUDeviceStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUDeviceStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of Rack PDU status information."
::= { rPDUDevice 2 }
rPDUDeviceStatusEntry OBJECT-TYPE
SYNTAX RPDUDeviceStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Status information from the Rack PDU being queried."
INDEX { rPDUDeviceStatusIndex }
::= { rPDUDeviceStatusTable 1 }
RPDUDeviceStatusEntry ::=
SEQUENCE {
rPDUDeviceStatusIndex INTEGER,
rPDUDeviceStatusName DisplayString,
rPDUDeviceStatusPower INTEGER,
rPDUDeviceStatusEnergy INTEGER,
rPDUDeviceStatusCommandPending INTEGER,
rPDUDeviceStatusLoadState INTEGER
}
rPDUDeviceStatusIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the Rack PDU status table entry."
::= { rPDUDeviceStatusEntry 1 }
rPDUDeviceStatusName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A user-defined string identifying the Rack PDU."
::= { rPDUDeviceStatusEntry 2 }
rPDUDeviceStatusPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The power consumption of the Rack PDU load in 1/100 of KWatts."
::= { rPDUDeviceStatusEntry 3 }
rPDUDeviceStatusEnergy OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A user resettable energy meter measuring Rack PDU load energy
consumption in tenths of kilowatt-hours."
::= { rPDUDeviceStatusEntry 4 }
rPDUDeviceStatusCommandPending OBJECT-TYPE
SYNTAX INTEGER {
commandPending (1),
noCommandPending (2),
commandPendingUnknown (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether the device is processing a pending command.
If the commandPendingUnknown (3) value is returned, all devices
receiving power from the Rack PDU should be shut down.
The Rack PDU's power should then be cycled to clear this condition."
::= { rPDUDeviceStatusEntry 5 }
rPDUDeviceStatusLoadState OBJECT-TYPE
SYNTAX RpduLowNormalNearOverloadType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the present load status of the Rack PDU Device being
queried."
::= { rPDUDeviceStatusEntry 6 }
-- rPDU Device Config
rPDUDeviceConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUDeviceConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of Rack PDU configuration data."
::= { rPDUDevice 3 }
rPDUDeviceConfigEntry OBJECT-TYPE
SYNTAX RPDUDeviceConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Configuration data from the Rack PDU being queried."
INDEX { rPDUDeviceConfigIndex }
::= { rPDUDeviceConfigTable 1 }
RPDUDeviceConfigEntry ::=
SEQUENCE {
rPDUDeviceConfigIndex INTEGER,
rPDUDeviceConfigName DisplayString,
rPDUDeviceConfigLocation DisplayString,
rPDUDeviceConfigColdstartDelay INTEGER,
rPDUDeviceCfgLowLoadPwrThresh INTEGER,
rPDUDeviceCfgNerOvloadPwrThresh INTEGER,
rPDUDeviceCfgOverloadPwrThresh INTEGER,
rPDUDeviceConfigPowerHeadroom INTEGER,
rPDUDeviceConfigPeakPower INTEGER,
rPDUDeviceCfgPeakPwrStartTime DisplayString,
rPDUDeviceConfigPeakPwrCapTime DisplayString,
rPDUDeviceCfgPeakPowerHeadroom INTEGER,
rPDUDeviceCfgEnergyStartTime DisplayString
}
rPDUDeviceConfigIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the Rack PDU table entry."
::= { rPDUDeviceConfigEntry 1 }
rPDUDeviceConfigName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A user-defined string identifying the Rack PDU."
::= { rPDUDeviceConfigEntry 2 }
rPDUDeviceConfigLocation OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Location of the Rack PDU."
::= { rPDUDeviceConfigEntry 3 }
rPDUDeviceConfigColdstartDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The amount of delay, measured in seconds, between when power is
provided to the Rack PDU and when the Rack PDU provides basic
master power to the outlets."
::= { rPDUDeviceConfigEntry 4 }
rPDUDeviceCfgLowLoadPwrThresh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined low power draw alarm threshold, measured in tenths
of kilowatts."
::= { rPDUDeviceConfigEntry 5 }
rPDUDeviceCfgNerOvloadPwrThresh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined near power overload threshold, measured in tenths
of kilowatts."
::= { rPDUDeviceConfigEntry 6 }
rPDUDeviceCfgOverloadPwrThresh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined power overload threshold, measured in tenths of
kilowatts."
::= { rPDUDeviceConfigEntry 7 }
rPDUDeviceConfigPowerHeadroom OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of input power that is available to the connected
devices in hundredths of kilowatt-hours."
::= { rPDUDeviceConfigEntry 8 }
rPDUDeviceConfigPeakPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The highest input power level recorded by the connected
devices in hundredths of kilowatt-hours."
::= { rPDUDeviceConfigEntry 9 }
rPDUDeviceCfgPeakPwrStartTime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time, in hh:mm:ss, when the device started recording the highest
input power level."
::= { rPDUDeviceConfigEntry 10 }
rPDUDeviceConfigPeakPwrCapTime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time, in hh:mm:ss, when the highest input power level was
recorded by the device."
::= { rPDUDeviceConfigEntry 11 }
rPDUDeviceCfgPeakPowerHeadroom OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The highest level of input power that is available to the connected
devices in hundredths of kilowatt-hours."
::= { rPDUDeviceConfigEntry 12 }
rPDUDeviceCfgEnergyStartTime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time, in hh:mm:ss, when the device started recording the input
energy level."
::= { rPDUDeviceConfigEntry 13 }
-- rPDU Device Properties
rPDUDevicePropertiesTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUDevicePropertiesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of Rack PDU properties."
::= { rPDUDevice 4 }
rPDUDevicePropertiesEntry OBJECT-TYPE
SYNTAX RPDUDevicePropertiesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Properties of the Rack PDU being queried."
INDEX { rPDUDevicePropertiesIndex }
::= { rPDUDevicePropertiesTable 1 }
RPDUDevicePropertiesEntry ::=
SEQUENCE {
rPDUDevicePropertiesIndex INTEGER,
rPDUDevicePropertiesName DisplayString,
rPDUDevicePropertiesNumOutlets INTEGER,
rPDUDevicePropertiesNumSwdOuts INTEGER,
rPDUDevicePropertiesNumMtrdOuts INTEGER,
rPDUDevicePropertiesNumPhases INTEGER,
rPDUDevicePropertiesNumBreakers INTEGER,
rPDUDevicePropertiesMaxCurntRtg INTEGER,
rPDUDevicePropertiesOutlayout INTEGER
}
rPDUDevicePropertiesIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the Rack PDU properties table entry."
::= { rPDUDevicePropertiesEntry 1 }
rPDUDevicePropertiesName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A user-defined string identifying the Rack PDU."
::= { rPDUDevicePropertiesEntry 2 }
rPDUDevicePropertiesNumOutlets OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of outlets on the Rack PDU."
::= { rPDUDevicePropertiesEntry 3 }
rPDUDevicePropertiesNumSwdOuts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of switched outlets on the Rack PDU."
::= { rPDUDevicePropertiesEntry 4 }
rPDUDevicePropertiesNumMtrdOuts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of metered outlets on the Rack PDU."
::= { rPDUDevicePropertiesEntry 5 }
rPDUDevicePropertiesNumPhases OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of phases present in the Rack PDU."
::= { rPDUDevicePropertiesEntry 6 }
rPDUDevicePropertiesNumBreakers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of breakers present in the Rack PDU."
::= { rPDUDevicePropertiesEntry 7 }
rPDUDevicePropertiesMaxCurntRtg OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum current rating, measured in Amps, for the Rack PDU."
::= { rPDUDevicePropertiesEntry 8 }
rPDUDevicePropertiesOutlayout OBJECT-TYPE
SYNTAX INTEGER {
phaseToNeutral (1),
phaseToPhase (2),
phaseToNeutralGrouped (3),
phaseToPhaseGrouped (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase wiring for the Rack PDU outlets. PhaseToNeutral and
PhaseToPhase: outlets wired consecutively; PhaseToNeutralGrouped
and PhaseToPhaseGrouped: groups of outlets wired consecutively."
::= { rPDUDevicePropertiesEntry 9 }
-- rPDU Device Control
rPDUDeviceControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUDeviceControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of Rack PDU control data."
::= { rPDUDevice 5 }
rPDUDeviceControlEntry OBJECT-TYPE
SYNTAX RPDUDeviceControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Control data from the Rack PDU being queried."
INDEX { rPDUDeviceControlIndex }
::= { rPDUDeviceControlTable 1 }
RPDUDeviceControlEntry ::=
SEQUENCE {
rPDUDeviceControlIndex INTEGER,
rPDUDeviceControlName DisplayString,
rPDUDeviceControlCommand INTEGER
}
rPDUDeviceControlIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the Rack PDU control table entry."
::= { rPDUDeviceControlEntry 1 }
rPDUDeviceControlName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A user-defined string identifying the Rack PDU."
::= { rPDUDeviceControlEntry 2 }
rPDUDeviceControlCommand OBJECT-TYPE
SYNTAX INTEGER {
turnAllOnNow (1),
turnAllOnSequence (2),
turnAllOffNow (3),
rebootAllNow (4),
rebootAllSequence (5),
noCommand (6),
turnAllOffSequence (7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this OID to turnAllOnNow (1) will turn all outlets on
immediately. Setting this OID to turnAllOnSequence (2) will turn
all outlets on as defined by each outlet's sPDUOutletPowerOnTime
OID value. Setting this OID to turnAllOff (3) will turn all outlets
off immediately. Setting this OID to rebootAllNow (4) will reboot
all outlets immediately. Setting this OID to rebootAllSequence (5)
reboots all outlets, with power returned to the outlets in the
sequence defined by each outlet's rPDUOutSwitchedCfgPowerOnTime
OID value. Setting this OID to rebootAllSequence (5) will cause a
turnAllOffSequence to be performed. Once all outlets are off, the
Rack PDU will then delay the rPDUOutSwtchedCfgRebootDuration
OID time, and then perform a turnAllOnSequence. Setting this OID
to turnAllOffSequence (7) will turn all outlets off as defined by
each outlet's rPDUOutSwitchedCfgPowerOffTime OID value.
Getting this OID will return the noCommand (6) value."
::= { rPDUDeviceControlEntry 3 }
rPDUPhase OBJECT IDENTIFIER ::= { rPDU 120 }
-- rPDU Phase Data
rPDUPhaseTableSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of connected Rack PDU phases."
::= { rPDUPhase 1 }
-- rPDU Phase Status
rPDUPhaseStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUPhaseStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of Rack PDU phase status data."
::= { rPDUPhase 2 }
rPDUPhaseStatusEntry OBJECT-TYPE
SYNTAX RPDUPhaseStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Status data from the currently queried Rack PDU phase."
INDEX { rPDUPhaseStatusIndex }
::= { rPDUPhaseStatusTable 1 }
RPDUPhaseStatusEntry ::=
SEQUENCE {
rPDUPhaseStatusIndex INTEGER,
rPDUPhaseStatusNumber INTEGER,
rPDUPhaseStatusLoadState INTEGER,
rPDUPhaseStatusCurrent INTEGER,
rPDUPhaseStatusVoltage INTEGER,
rPDUPhaseStatusPower INTEGER
}
rPDUPhaseStatusIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the Rack PDU phase status table entry."
::= { rPDUPhaseStatusEntry 1 }
rPDUPhaseStatusNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The numeric phase ID."
::= { rPDUPhaseStatusEntry 2 }
rPDUPhaseStatusLoadState OBJECT-TYPE
SYNTAX RpduLowNormalNearOverloadType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the present load status of the Rack PDU phase being
queried."
::= { rPDUPhaseStatusEntry 3 }
rPDUPhaseStatusCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current draw, in tenths of Amps, of the load on
the Rack PDU phase being queried."
::= { rPDUPhaseStatusEntry 4 }
rPDUPhaseStatusVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the Voltage, in Volts, of the Rack PDU
phase being queried."
::= { rPDUPhaseStatusEntry 5 }
rPDUPhaseStatusPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the load power, in hundredths of kilowatts, consumed on
the Rack PDU phase being queried."
::= { rPDUPhaseStatusEntry 6 }
-- rPDU Phase Config
rPDUPhaseConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUPhaseConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of Rack PDU phase configuration data."
::= { rPDUPhase 3 }
rPDUPhaseConfigEntry OBJECT-TYPE
SYNTAX RPDUPhaseConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Configuration data from the currently queried Rack PDU phase."
INDEX { rPDUPhaseConfigIndex }
::= { rPDUPhaseConfigTable 1 }
RPDUPhaseConfigEntry ::=
SEQUENCE {
rPDUPhaseConfigIndex INTEGER,
rPDUPhaseConfigNumber INTEGER,
rPDUPhaseCfgOverloadRestriction INTEGER,
rPDUPhCfgLowLoadCurntThreshold INTEGER,
rPDUPhCfgNerOverloadCurntThresh INTEGER,
rPDUPhCfgOverloadCurntThreshold INTEGER
}
rPDUPhaseConfigIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the Rack PDU phase configuration table entry."
::= { rPDUPhaseConfigEntry 1 }
rPDUPhaseConfigNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The numeric phase ID."
::= { rPDUPhaseConfigEntry 2 }
rPDUPhaseCfgOverloadRestriction OBJECT-TYPE
SYNTAX INTEGER {
alwaysAllowTurnON (1),
restrictOnNearOverload (2),
restrictOnOverload (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This OID controls the behavior of a Switched Rack PDU phase
when an overload condition is possible and additional outlets
are requested to be turned on. Setting this OID to
alwaysAllowTurnON (1) will always allow the outlets on the
corresponding phase to turn on. Setting this OID to
restrictOnNearOverload (2) will not allow outlets on the
corresponding phase to turn on if the
rPDULoadConfigNearOverloadThreshold OID is exceeded. Setting
this OID to restrictOnOverload (3) will not allow outlets on the
corresponding phase to turn on if the
rPDULoadConfigOverloadThreshold OID is exceeded."
::= { rPDUPhaseConfigEntry 3 }
rPDUPhCfgLowLoadCurntThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined threshold for low phase current load, in Amps."
::= { rPDUPhaseConfigEntry 4 }
rPDUPhCfgNerOverloadCurntThresh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined near phase overload warning threshold in Amps."
::= { rPDUPhaseConfigEntry 5 }
rPDUPhCfgOverloadCurntThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined phase overload current threshold in Amps."
::= { rPDUPhaseConfigEntry 6 }
rPDUOutlet OBJECT IDENTIFIER ::= { rPDU 130 }
-- rPDU Outlet Data
rPDUOutletSwitched OBJECT IDENTIFIER ::= { rPDUOutlet 1 }
-- rPDU Switched Outlet Data
rPDUOutletSwitchedTableSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of switched outlets on connected Rack PDUs."
::= { rPDUOutletSwitched 1 }
-- rPDU Switched Outlet Status
rPDUOutletSwitchedStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUOutletSwitchedStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of Rack PDU switched outlet status information."
::= { rPDUOutletSwitched 2 }
rPDUOutletSwitchedStatusEntry OBJECT-TYPE
SYNTAX RPDUOutletSwitchedStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Status information for the currently-queried Rack PDU switched
outlet."
INDEX { rPDUOutletSwitchedStatusIndex }
::= { rPDUOutletSwitchedStatusTable 1 }
RPDUOutletSwitchedStatusEntry ::=
SEQUENCE {
rPDUOutletSwitchedStatusIndex INTEGER,
rPDUOutletSwitchedStatusNumber INTEGER,
rPDUOutletSwitchedStatusName DisplayString,
rPDUOutletSwitchedStatusState INTEGER,
rPDUOutletSwitchedStatCmdPnding INTEGER,
rPDUOutletSwitchedStatPhLayout RpduOutletPhaseLayoutType
}
rPDUOutletSwitchedStatusIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the Rack PDU switched outlet status information table
entry."
::= { rPDUOutletSwitchedStatusEntry 1 }
rPDUOutletSwitchedStatusNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The numeric switched outlet ID."
::= { rPDUOutletSwitchedStatusEntry 2 }
rPDUOutletSwitchedStatusName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined switched outlet ID string."
::= { rPDUOutletSwitchedStatusEntry 3 }
rPDUOutletSwitchedStatusState OBJECT-TYPE
SYNTAX INTEGER {
on (1),
off (2),
unknown (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the present status of the Rack PDU switched outlet
being queried."
::= { rPDUOutletSwitchedStatusEntry 4 }
rPDUOutletSwitchedStatCmdPnding OBJECT-TYPE
SYNTAX INTEGER {
commandPending (1),
noCommandPending (2),
commandPendingUnknown (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether the device is processing a command for this
outlet. If the commandPendingUnknown (3) value is returned,
all devices receiving power from the Rack PDU should be shut down.
The Rack PDU's power should then be cycled to clear this condition."
::= { rPDUOutletSwitchedStatusEntry 5 }
rPDUOutletSwitchedStatPhLayout OBJECT-TYPE
SYNTAX RpduOutletPhaseLayoutType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Phase description of the currently-queried Rack PDU switched outlet."
::= { rPDUOutletSwitchedStatusEntry 6 }
-- rPDU Switched Outlet Config
rPDUOutletSwitchedConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUOutletSwitchedConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of Rack PDU switched outlet configuration data."
::= { rPDUOutletSwitched 3 }
rPDUOutletSwitchedConfigEntry OBJECT-TYPE
SYNTAX RPDUOutletSwitchedConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Configuration data from the currently-queried Rack PDU switched
outlet."
INDEX { rPDUOutletSwitchedConfigIndex }
::= { rPDUOutletSwitchedConfigTable 1 }
RPDUOutletSwitchedConfigEntry ::=
SEQUENCE {
rPDUOutletSwitchedConfigIndex INTEGER,
rPDUOutletSwitchedConfigNumber INTEGER,
rPDUOutletSwitchedConfigName DisplayString,
rPDUOutSwitchedCfgPowerOnTime INTEGER,
rPDUOutSwitchedCfgPowerOffTime INTEGER,
rPDUOutSwtchedCfgRebootDuration INTEGER
}
rPDUOutletSwitchedConfigIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the Rack PDU switched outlet configuration table entry."
::= { rPDUOutletSwitchedConfigEntry 1 }
rPDUOutletSwitchedConfigNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The numeric switched outlet ID."
::= { rPDUOutletSwitchedConfigEntry 2 }
rPDUOutletSwitchedConfigName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined switched outlet ID string."
::= { rPDUOutletSwitchedConfigEntry 3 }
rPDUOutSwitchedCfgPowerOnTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The amount of time, in seconds, between when power is provided to
the Rack PDU and when this switched outlet starts providing power."
::= { rPDUOutletSwitchedConfigEntry 4 }
rPDUOutSwitchedCfgPowerOffTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The amount of time, in seconds, this outlet will delay turning off."
::= { rPDUOutletSwitchedConfigEntry 5 }
rPDUOutSwtchedCfgRebootDuration OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"After turning off power during a reboot sequence, the amount of
time, in seconds, to wait before turning on power to this outlet
again."
::= { rPDUOutletSwitchedConfigEntry 6 }
-- rPDU Switched Outlet Control
rPDUOutletSwitchedControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUOutletSwitchedControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of Rack PDU switched outlet control data."
::= { rPDUOutletSwitched 4 }
rPDUOutletSwitchedControlEntry OBJECT-TYPE
SYNTAX RPDUOutletSwitchedControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Control data for the currently-queried Rack PDU switched outlet."
INDEX { rPDUOutletSwitchedControlIndex }
::= { rPDUOutletSwitchedControlTable 1 }
RPDUOutletSwitchedControlEntry ::=
SEQUENCE {
rPDUOutletSwitchedControlIndex INTEGER,
rPDUOutletSwitchedControlNumber INTEGER,
rPDUOutletSwitchedControlName DisplayString,
rPDUOutletSwitchedControlCmd INTEGER
}
rPDUOutletSwitchedControlIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the Rack PDU switched outlet control data table entry."
::= { rPDUOutletSwitchedControlEntry 1 }
rPDUOutletSwitchedControlNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The numeric switched outlet ID."
::= { rPDUOutletSwitchedControlEntry 2 }
rPDUOutletSwitchedControlName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined switched outlet ID string."
::= { rPDUOutletSwitchedControlEntry 3 }
rPDUOutletSwitchedControlCmd OBJECT-TYPE
SYNTAX INTEGER {
outletOn (1),
outletOff (2),
outletReboot (3),
outletUnknown (4),
outletOnWithDelay (5),
outletOffWithDelay (6),
outletRebootWithDelay (7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Getting this variable will return the outlet state. If the outlet is
on, the outletOn (1) value will be returned. If the outlet is off,
the outletOff (2) value will be returned. If the state of the outlet
cannot be determined, the outletUnknown (4) value will be returned.
If the outletUnknown condition should occur, all devices receiving
power from the PDU should be shut down. The PDU's power should then
be cycled to clear this condition. Setting this variable to
outletOn (1) will turn the outlet on. Setting this variable to
outletOff (2) will turn the outlet off. Setting this variable to
outletReboot (3) will reboot the outlet. Setting this variable to
outletOnWithDelay (5) will turn the outlet on after the
rPDUOutSwitchedCfgPowerOnTime OID has elapsed. Setting this
variable to outletOffWithDelay (6) will turn the outlet off after
the rPDUOutSwitchedCfgPowerOffTime OID has elapsed. Setting
this variable to outletRebootWithDelay (7) will turn the outlet off
after the rPDUOutSwitchedCfgPowerOffTime OID has elapsed,
wait the rPDUOutSwtchedCfgRebootDuration OID time, then turn
the outlet back on."
::= { rPDUOutletSwitchedControlEntry 4 }
rPDUOutletMetered OBJECT IDENTIFIER ::= { rPDUOutlet 2 }
-- rPDU Metered Outlet Data
rPDUOutletMeteredTableSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of metered outlets on connected Rack PDUs."
::= { rPDUOutletMetered 1 }
-- rPDU Metered Outlet Status
rPDUOutletMeteredStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUOutletMeteredStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of Rack PDU metered outlet status data."
::= { rPDUOutletMetered 2 }
rPDUOutletMeteredStatusEntry OBJECT-TYPE
SYNTAX RPDUOutletMeteredStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Status data from the currently-queried Rack PDU metered outlet."
INDEX { rPDUOutletMeteredStatusIndex }
::= { rPDUOutletMeteredStatusTable 1 }
RPDUOutletMeteredStatusEntry ::=
SEQUENCE {
rPDUOutletMeteredStatusIndex INTEGER,
rPDUOutletMeteredStatusNumber INTEGER,
rPDUOutletMeteredStatusName DisplayString,
rPDUOutletMeteredStatusLayout INTEGER,
rPDUOutMeteredStatPowerRating INTEGER,
rPDUOutletMeteredStatusCurrent INTEGER,
rPDUOutletMeteredStatusEnergy INTEGER,
rPDUOutletMeteredStatusPower INTEGER,
rPDUOutletMeteredStatPeakPower INTEGER,
rPDUOutMeteredStatPeakPwrTime DisplayString,
rPDUOutMeteredStatusLoadState INTEGER
}
rPDUOutletMeteredStatusIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the Rack PDU metered status table entry."
::= { rPDUOutletMeteredStatusEntry 1 }
rPDUOutletMeteredStatusNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The numeric metered outlet ID."
::= { rPDUOutletMeteredStatusEntry 2 }
rPDUOutletMeteredStatusName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined metered outlet ID string."
::= { rPDUOutletMeteredStatusEntry 3 }
rPDUOutletMeteredStatusLayout OBJECT-TYPE
SYNTAX RpduOutletPhaseLayoutType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Phase description of currently queried Rack PDU metered outlet."
::= { rPDUOutletMeteredStatusEntry 4 }
rPDUOutMeteredStatPowerRating OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The power rating for the currently queried Rack PDU metered outlet."
::= { rPDUOutletMeteredStatusEntry 5 }
rPDUOutletMeteredStatusCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current draw, in Amps, of the load on the Rack PDU
outlet being queried."
::= { rPDUOutletMeteredStatusEntry 6 }
rPDUOutletMeteredStatusEnergy OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A user resettable energy meter measuring Rack PDU load energy
consumption in kilowatt-hours."
::= { rPDUOutletMeteredStatusEntry 7 }
rPDUOutletMeteredStatusPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the power draw of the load on the Rack PDU outlet being
queried."
::= { rPDUOutletMeteredStatusEntry 8 }
rPDUOutletMeteredStatPeakPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The highest power level recorded by the currently queried Rack PDU
metered outlet, in kilowatts."
::= { rPDUOutletMeteredStatusEntry 9 }
rPDUOutMeteredStatPeakPwrTime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the date and time that peak power consumption occured"
::= { rPDUOutletMeteredStatusEntry 10 }
rPDUOutMeteredStatusLoadState OBJECT-TYPE
SYNTAX RpduLowNormalNearOverloadType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the present load status of the Rack PDU Outlet being
queried."
::= { rPDUOutletMeteredStatusEntry 11 }
-- rPDU Metered Outlet Config
rPDUOutletMeteredConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUOutletMeteredConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of Rack PDU metered outlet configuration data."
::= { rPDUOutletMetered 4 }
rPDUOutletMeteredConfigEntry OBJECT-TYPE
SYNTAX RPDUOutletMeteredConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Configuration data from the currently queried Rack PDU metered
outlet."
INDEX { rPDUOutletMeteredConfigIndex }
::= { rPDUOutletMeteredConfigTable 1 }
RPDUOutletMeteredConfigEntry ::=
SEQUENCE {
rPDUOutletMeteredConfigIndex INTEGER,
rPDUOutletMeteredConfigNumber INTEGER,
rPDUOutletMeteredConfigName DisplayString,
rPDUOutMtredCfgLowLdCurntThresh INTEGER,
rPDUOutMtrdCfgNrOvdCurntThresh INTEGER,
rPDUOutMtredCfgOvrldCurntThresh INTEGER
}
rPDUOutletMeteredConfigIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the Rack PDU metered outlet configuration table entry."
::= { rPDUOutletMeteredConfigEntry 1 }
rPDUOutletMeteredConfigNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The numeric switched outlet ID."
::= { rPDUOutletMeteredConfigEntry 2 }
rPDUOutletMeteredConfigName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined metered outlet ID string."
::= { rPDUOutletMeteredConfigEntry 3 }
rPDUOutMtredCfgLowLdCurntThresh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined low load outlet current threshold, in Amps."
::= { rPDUOutletMeteredConfigEntry 4 }
rPDUOutMtrdCfgNrOvdCurntThresh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined near outlet overload warning threshold, in Amps."
::= { rPDUOutletMeteredConfigEntry 5 }
rPDUOutMtredCfgOvrldCurntThresh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined outlet overload current threshold, in Amps."
::= { rPDUOutletMeteredConfigEntry 6 }
rPDUOutMeteredEnergyStartTime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time, in hh:mm:ss, when the currently queried Rack PDU metered
outlet started recording the input energy level."
::= { rPDUOutletMetered 5 }
rPDUOutMeteredPeakPwrStartTime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time, in hh:mm:ss, when the currently queried Rack PDU metered
outlet started recording the highest level of input power that is
available to the connected device."
::= { rPDUOutletMetered 6 }
rPDUPowerSupply OBJECT IDENTIFIER ::= { rPDU 140 }
-- the rPDU Power Supply group
rPDUPowerSupplyAlarmD OBJECT-TYPE
SYNTAX INTEGER {
allAvailablePowerSuppliesOK (1),
powerSupplyFailed (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Getting this OID will return the status of the power supply alarm."
::= { rPDUPowerSupply 1 }
rPDUPowerSupplyVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The voltage provided by the power supply in tenths of volts."
::= { rPDUPowerSupply 2 }
rPDUSensor OBJECT IDENTIFIER ::= { rPDU 150 }
-- rPDU Sensor Data
rPDUSensorStatus OBJECT IDENTIFIER ::= { rPDUSensor 1 }
-- rPDU Sensor Status Data
rPDUSensorStatusTableSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of connected temperature sensors."
::= { rPDUSensorStatus 1 }
-- rPDU Temperature Sensor Status
rPDUSensorStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUSensorStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of temperature sensor status data."
::= { rPDUSensorStatus 2 }
rPDUSensorStatusEntry OBJECT-TYPE
SYNTAX RPDUSensorStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Status information from the temperature sensor being queried."
INDEX { rPDUSensorStatusIndex }
::= { rPDUSensorStatusTable 1 }
RPDUSensorStatusEntry ::=
SEQUENCE {
rPDUSensorStatusIndex INTEGER,
rPDUSensorStatusName DisplayString,
rPDUSensorStatusType INTEGER
}
rPDUSensorStatusIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the status data table entry."
::= { rPDUSensorStatusEntry 1 }
rPDUSensorStatusName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined sensor ID string."
::= { rPDUSensorStatusEntry 2 }
rPDUSensorStatusType OBJECT-TYPE
SYNTAX INTEGER {
none (1),
temperature (2),
temperatureHumidity (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the sensor."
::= { rPDUSensorStatusEntry 3 }
rPDUSensorTemp OBJECT IDENTIFIER ::= { rPDUSensor 2 }
-- rPDU Temperature Sensor Data
rPDUSensorTempTableSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of connected temperature sensors."
::= { rPDUSensorTemp 1 }
-- rPDU Temperature Sensor Status
rPDUSensorTempStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUSensorTempStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of temperature sensor status data."
::= { rPDUSensorTemp 2 }
rPDUSensorTempStatusEntry OBJECT-TYPE
SYNTAX RPDUSensorTempStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Status information from the temperature sensor being queried."
INDEX { rPDUSensorTempStatusIndex }
::= { rPDUSensorTempStatusTable 1 }
RPDUSensorTempStatusEntry ::=
SEQUENCE {
rPDUSensorTempStatusIndex INTEGER,
rPDUSensorTempStatusName DisplayString,
rPDUSensorTempStatusCommStatus INTEGER,
rPDUSensorTempStatusTempF INTEGER,
rPDUSensorTempStatusTempC INTEGER,
rPDUSensorTempStatusAlarmStatus INTEGER
}
rPDUSensorTempStatusIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the temperature status data table entry."
::= { rPDUSensorTempStatusEntry 1 }
rPDUSensorTempStatusName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined temperature-humidity sensor ID string."
::= { rPDUSensorTempStatusEntry 2 }
rPDUSensorTempStatusCommStatus OBJECT-TYPE
SYNTAX RpduCommNoneOKLostType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The communications status of the sensor."
::= { rPDUSensorTempStatusEntry 3 }
rPDUSensorTempStatusTempF OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sensor temperature reading in tenths of degrees Fahrenheit."
::= { rPDUSensorTempStatusEntry 4 }
rPDUSensorTempStatusTempC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sensor temperature reading in tenths of degrees Celsius."
::= { rPDUSensorTempStatusEntry 5 }
rPDUSensorTempStatusAlarmStatus OBJECT-TYPE
SYNTAX RpduNotPBMinLowNrmlOHiMaxType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The alarm status of the sensor."
::= { rPDUSensorTempStatusEntry 6 }
-- rPDU Temperature Sensor Config
rPDUSensorTempConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUSensorTempConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of temperature-humidity sensor configuration data."
::= { rPDUSensorTemp 3 }
rPDUSensorTempConfigEntry OBJECT-TYPE
SYNTAX RPDUSensorTempConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Configuration data from the temperature-humidity sensor being
queried."
INDEX { rPDUSensorTempConfigIndex }
::= { rPDUSensorTempConfigTable 1 }
RPDUSensorTempConfigEntry ::=
SEQUENCE {
rPDUSensorTempConfigIndex INTEGER,
rPDUSensorTempConfigName DisplayString,
rPDUSensorTempCfgTempMaxThreshF INTEGER,
rPDUSnsorTempCfgTempHighThreshF INTEGER,
rPDUSnsorTempCfgTempHysteresisF INTEGER,
rPDUSensorTempCfgTempMaxThreshC INTEGER,
rPDUSnsorTempCfgTempHighThreshC INTEGER,
rPDUSnsorTempCfgTempHysteresisC INTEGER,
rPDUSnsorTempCfgAlarmGeneration INTEGER
}
rPDUSensorTempConfigIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the temperature-humidity sensor configuration data
table entry."
::= { rPDUSensorTempConfigEntry 1 }
rPDUSensorTempConfigName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined temperature-humidity sensor ID string."
::= { rPDUSensorTempConfigEntry 2 }
rPDUSensorTempCfgTempMaxThreshF OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The sensor maximum temperature alarm threshold in Fahrenheit."
::= { rPDUSensorTempConfigEntry 3 }
rPDUSnsorTempCfgTempHighThreshF OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The sensor high temperature warning alarm threshold in Fahrenheit."
::= { rPDUSensorTempConfigEntry 4 }
rPDUSnsorTempCfgTempHysteresisF OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The sensor temperature hysteresis setting in Fahrenheit."
::= { rPDUSensorTempConfigEntry 5 }
rPDUSensorTempCfgTempMaxThreshC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The sensor maximum temperature alarm threshold in Celsius."
::= { rPDUSensorTempConfigEntry 6 }
rPDUSnsorTempCfgTempHighThreshC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The sensor high temperature warning alarm threshold in Celsius."
::= { rPDUSensorTempConfigEntry 7 }
rPDUSnsorTempCfgTempHysteresisC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The sensor temperature hysteresis setting in Celsius."
::= { rPDUSensorTempConfigEntry 8 }
rPDUSnsorTempCfgAlarmGeneration OBJECT-TYPE
SYNTAX RpduEnableDisableType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the Temp Alarm Generation is enabled."
::= { rPDUSensorTempConfigEntry 9 }
rPDUSensorHumidity OBJECT IDENTIFIER ::= { rPDUSensor 3 }
-- rPDU Humidity Sensor
rPDUSensorHumidityTableSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of connected temperature-humidity sensors."
::= { rPDUSensorHumidity 1 }
-- rPDU Humidity Sensor Status
rPDUSensorHumidityStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUSensorHumidityStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of temperature-humidity sensor status data."
::= { rPDUSensorHumidity 2 }
rPDUSensorHumidityStatusEntry OBJECT-TYPE
SYNTAX RPDUSensorHumidityStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Status information from the temperature-humidity sensor being
queried."
INDEX { rPDUSensorHumidityStatusIndex }
::= { rPDUSensorHumidityStatusTable 1 }
RPDUSensorHumidityStatusEntry ::=
SEQUENCE {
rPDUSensorHumidityStatusIndex INTEGER,
rPDUSensorHumidityStatusName DisplayString,
rPDUSnsorHumidityStatCommStatus INTEGER,
rPDUSnsorHumStatRelativeHumdity INTEGER,
rPDUSnsorHumStatusAlarmStatus INTEGER
}
rPDUSensorHumidityStatusIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the temperature-humidity status data table entry."
::= { rPDUSensorHumidityStatusEntry 1 }
rPDUSensorHumidityStatusName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined temperature-humidity sensor ID string."
::= { rPDUSensorHumidityStatusEntry 2 }
rPDUSnsorHumidityStatCommStatus OBJECT-TYPE
SYNTAX RpduCommNoneOKLostType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The communications status of the sensor."
::= { rPDUSensorHumidityStatusEntry 3 }
rPDUSnsorHumStatRelativeHumdity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sensor humidity reading in percent relative humidity."
::= { rPDUSensorHumidityStatusEntry 4 }
rPDUSnsorHumStatusAlarmStatus OBJECT-TYPE
SYNTAX RpduNotPBMinLowNrmlOHiMaxType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The alarm status of the sensor."
::= { rPDUSensorHumidityStatusEntry 5 }
-- rPDU Humidity Sensor Config
rPDUSensorHumidityConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUSensorHumidityConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of temperature-humidity sensor configuration data."
::= { rPDUSensorHumidity 3 }
rPDUSensorHumidityConfigEntry OBJECT-TYPE
SYNTAX RPDUSensorHumidityConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Configuration data from the temperature-humidity sensor being
queried."
INDEX { rPDUSensorHumidityConfigIndex }
::= { rPDUSensorHumidityConfigTable 1 }
RPDUSensorHumidityConfigEntry ::=
SEQUENCE {
rPDUSensorHumidityConfigIndex INTEGER,
rPDUSensorHumidityConfigName DisplayString,
rPDUSnsorHumCfgHumdityLowThresh INTEGER,
rPDUSnsorHumCfgHumdityMinThresh INTEGER,
rPDUSnsorHumCfgHumdtyHysteresis INTEGER,
rPDUSnsorHumCfgAlarmGeneration INTEGER
}
rPDUSensorHumidityConfigIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the temperature-humidity sensor configuration data
table entry."
::= { rPDUSensorHumidityConfigEntry 1 }
rPDUSensorHumidityConfigName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined temperature-humidity sensor ID string."
::= { rPDUSensorHumidityConfigEntry 2 }
rPDUSnsorHumCfgHumdityLowThresh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The sensor low humidity warning alarm threshold in percent relative
humidity."
::= { rPDUSensorHumidityConfigEntry 3 }
rPDUSnsorHumCfgHumdityMinThresh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The sensor minimum humidity alarm threshold in percent relative
humidity."
::= { rPDUSensorHumidityConfigEntry 4 }
rPDUSnsorHumCfgHumdtyHysteresis OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The sensor humidity hysteresis setting in percent relative humidity."
::= { rPDUSensorHumidityConfigEntry 5 }
rPDUSnsorHumCfgAlarmGeneration OBJECT-TYPE
SYNTAX RpduEnableDisableType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the Humidity Alarm Generation is enabled."
::= { rPDUSensorHumidityConfigEntry 6 }
rPDUSensorDiscrete OBJECT IDENTIFIER ::= { rPDUSensor 4 }
-- rPDU Discrete Sensor Data
rPDUSensorDiscreteTableSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of connected discrete sensors."
::= { rPDUSensorDiscrete 1 }
-- rPDU Discrete Sensor Status
rPDUSensorDiscreteStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUSensorDiscreteStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of discrete sensor status data."
::= { rPDUSensorDiscrete 2 }
rPDUSensorDiscreteStatusEntry OBJECT-TYPE
SYNTAX RPDUSensorDiscreteStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Status information from the discrete sensor being queried."
INDEX { rPDUSensorDiscreteStatusIndex }
::= { rPDUSensorDiscreteStatusTable 1 }
RPDUSensorDiscreteStatusEntry ::=
SEQUENCE {
rPDUSensorDiscreteStatusIndex INTEGER,
rPDUSensorDiscreteStatusName DisplayString,
rPDUSnsorDiscreteStatCurntState INTEGER,
rPDUSnsorDiscreteStatAlarmState INTEGER
}
rPDUSensorDiscreteStatusIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the discrete sensor status data table entry."
::= { rPDUSensorDiscreteStatusEntry 1 }
rPDUSensorDiscreteStatusName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined discrete sensor ID string."
::= { rPDUSensorDiscreteStatusEntry 2 }
rPDUSnsorDiscreteStatCurntState OBJECT-TYPE
SYNTAX INTEGER {
open (1),
closed (2),
unknown (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current state of the discrete sensor, open, closed, or unknown."
::= { rPDUSensorDiscreteStatusEntry 3 }
rPDUSnsorDiscreteStatAlarmState OBJECT-TYPE
SYNTAX RpduNormalAlarmType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the alarm status of the discrete sensor input."
::= { rPDUSensorDiscreteStatusEntry 4 }
-- rPDU Discrete Sensor Config
rPDUSensorDiscreteConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RPDUSensorDiscreteConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of discrete sensor configuration data."
::= { rPDUSensorDiscrete 3 }
rPDUSensorDiscreteConfigEntry OBJECT-TYPE
SYNTAX RPDUSensorDiscreteConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Configuration data from the discrete sensor being queried."
INDEX { rPDUSensorDiscreteConfigIndex }
::= { rPDUSensorDiscreteConfigTable 1 }
RPDUSensorDiscreteConfigEntry ::=
SEQUENCE {
rPDUSensorDiscreteConfigIndex INTEGER,
rPDUSensorDiscreteConfigName DisplayString,
rPDUSnsorDiscreteCfgNormalState INTEGER,
rPDUSnsorDiscrteAlarmGeneration INTEGER
}
rPDUSensorDiscreteConfigIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the discrete sensor configuration data table entry."
::= { rPDUSensorDiscreteConfigEntry 1 }
rPDUSensorDiscreteConfigName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user-defined discrete sensor ID string."
::= { rPDUSensorDiscreteConfigEntry 2 }
rPDUSnsorDiscreteCfgNormalState OBJECT-TYPE
SYNTAX INTEGER {
open (1),
closed (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the normal state of the discrete input contact."
::= { rPDUSensorDiscreteConfigEntry 3 }
rPDUSnsorDiscrteAlarmGeneration OBJECT-TYPE
SYNTAX RpduEnableDisableType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether Discrete Alarm Generation is enabled."
::= { rPDUSensorDiscreteConfigEntry 4 }
mtrapargsD OBJECT IDENTIFIER ::= { rPDU 160 }
-- The mtrapargsD group
-- These OIDs allows traps to be sent with additional arguments
-- which may not be defined in the MIB.
contactNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This OID allows traps to be sent with an integer argument that
may not be defined in the MIB. A get of this OID will return 0."
::= { mtrapargsD 1 }
outletNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This OID allows traps to be sent with an integer argument that
may not be defined in the MIB. A get of this OID will return 0."
::= { mtrapargsD 2 }
mtrapargsString OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This OID allows traps to be sent with an octet string argument
that may not be defined in the MIB. A get of this OID will return
a NULL string."
::= { mtrapargsD 3 }
phaseNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This OID allows traps to be sent with an integer argument that
may not be defined in the MIB. A get of this OID will return 0."
::= { mtrapargsD 4 }
sensorNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This OID allows traps to be sent with an integer argument that
may not be defined in the MIB. A get of this OID will return 0."
::= { mtrapargsD 5 }
deviceNameD OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This OID allows traps to be sent with an octet string argument
that may not be defined in the MIB. A get of this OID will return
a NULL string."
::= { mtrapargsD 6 }
serialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This OID allows traps to be sent with an octet string argument that
may not be defined in the MIB. A get of this OID will return a NULL
string."
::= { mtrapargsD 7 }
testTrapargsInteger OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This OID allows traps to be sent with an integer argument that
may not be defined in the MIB. A get of this OID will return 0."
::= { mtrapargsD 8 }
events OBJECT IDENTIFIER ::= { rPDU 500 }
-- Traps
-- Annotations are provided for Novell's NMS product
--
-- Each trap has at least one variable (mtrapargsString) which always
-- appears as the last variable in the list. This variable contains either
-- a static or dynamically-constructed string which provides an enhanced
-- description of the trap's purpose and any pertinent information about
-- the trap.
deviceCommunicationLostCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Lost communication with device
has been re-established.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s lost communication with device has been re-established."
--#ARGUMENTS {1}
--#SEVERITY INFORMATIONAL
::= 1
deviceCommunicationLostSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"CRITICAL: Lost communication with device.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s lost communication with device."
--#ARGUMENTS {1}
--#SEVERITY CRITICAL
::= 2
componentCommLostCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Lost communication with an on board component
has been re-established.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s comm with on board component was re-established."
--#ARGUMENTS {1}
--#SEVERITY INFORMATIONAL
::= 3
componentCommLostSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"CRITICAL: Lost communication with an on board component.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s lost communication with an on board component."
--#ARGUMENTS {1}
--#SEVERITY CRITICAL
::= 4
cANBusOffCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: CAN bus off condition was cleared.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s CAN bus off was cleared."
--#ARGUMENTS {1}
--#SEVERITY INFORMATIONAL
::= 5
canBusOffSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"MINOR: CAN bus off condition was set.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s CAN bus off was set."
--#ARGUMENTS {1}
--#SEVERITY MINOR
::= 6
powerSupplyFailureCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Unit's power supply voltage is no longer out of
tolerance.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s unit's power supply voltage is no longer out of tolerance."
--#ARGUMENTS {1}
--#SEVERITY INFORMATIONAL
::= 7
powerSupplyFailureSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"CRITICAL: Unit's power supply voltage is out of tolerance.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s unit's power supply voltage is out of tolerance."
--#ARGUMENTS {1}
--#SEVERITY CRITICAL
::= 8
keypadButtonStuckCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Keypad button stuck has been cleared.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s keypad button no longer stuck."
--#ARGUMENTS {1}
--#SEVERITY INFORMATIONAL
::= 9
keypadButtonStuckSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"MINOR: Keypad button stuck has been set.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s keypad button stuck."
--#ARGUMENTS {1}
--#SEVERITY MINOR
::= 10
dryContactAbnormalCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, contactNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Dry Contact is no longer in an abnormal state.
The first argument is the serial number.
The second argument is the device name.
The third argument is the contact number."
--#SUMMARY "%s dry contact #%s is no longer in an abnormal state."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 11
dryContactAbnormalSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, contactNumber, mtrapargsString }
DESCRIPTION
"CRITICAL: Dry Contact has moved to an abnormal state.
The first argument is the serial number.
The second argument is the device name.
The third argument is the contact number."
--#SUMMARY "%s dry contact #%s has moved to an abnormal state."
--#ARGUMENTS {1,2}
--#SEVERITY CRITICAL
::= 12
deviceLowLoadCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Device load is no longer below the 'Low Load'
threshold value.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s device is no longer below the 'Low Load' threshold."
--#ARGUMENTS {1}
--#SEVERITY INFORMATIONAL
::= 13
deviceLowLoadSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"MINOR: Device load has fallen below the 'Low Load' threshold
value.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s Device load has fallen below the 'Low Load' threshold."
--#ARGUMENTS {1}
--#SEVERITY MINOR
::= 14
deviceNearOverLoadCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Device load no longer exceeds the 'Near Over Load'
threshold value.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s device not over 'Near Over Load' threshold."
--#ARGUMENTS {1}
--#SEVERITY INFORMATIONAL
::= 15
deviceNearOverLoadSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"MINOR: Device load has exceeded the 'Near Over Load' threshold
value.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s device is over the 'Near Over Load' threshold."
--#ARGUMENTS {1}
--#SEVERITY MINOR
::= 16
deviceOverLoadCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Device load no longer exceeds the 'Over Load'
threshold value.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s device not over the 'Over Load' threshold."
--#ARGUMENTS {1}
--#SEVERITY INFORMATIONAL
::= 17
deviceOverLoadSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"CRITICAL: Device load has exceeded the 'Over Load' threshold
value.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s device load is over the 'Over Load' threshold."
--#ARGUMENTS {1}
--#SEVERITY CRITICAL
::= 18
phaseLowLoadCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, phaseNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Phase load is no longer below the 'Low Load'
threshold value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the phase number."
--#SUMMARY "%s phase #%s load is no longer below 'Low Load' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 19
phaseLowLoadSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, phaseNumber, mtrapargsString }
DESCRIPTION
"MINOR: Phase load has fallen below the 'Low Load' threshold
value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the phase number."
--#SUMMARY "%s phase #%s load has fallen below the 'Low Load' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY MINOR
::= 20
phaseNearOverLoadCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, phaseNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Phase load no longer exceeds the 'Near Over Load'
threshold value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the phase number."
--#SUMMARY "%s phase #%s load not over 'Near Over Load' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 21
phaseNearOverLoadSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, phaseNumber, mtrapargsString }
DESCRIPTION
"MINOR: Phase load has exceeded the 'Near Over Load' threshold
value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the phase number."
--#SUMMARY "%s phase #%s load is over the 'Near Over Load' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY MINOR
::= 22
phaseOverLoadCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, phaseNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Phase load no longer exceeds the 'Over Load'
threshold value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the phase number."
--#SUMMARY "%s phase #%s load not over the 'Over Load' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 23
phaseOverLoadSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, phaseNumber, mtrapargsString }
DESCRIPTION
"CRITICAL: Phase load has exceeded the 'Over Load' threshold
value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the phase number."
--#SUMMARY "%s phase #%s load is over the 'Over Load' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY CRITICAL
::= 24
outletLowLoadCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Outlet load is no longer below the 'Low Load'
threshold value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the outlet number."
--#SUMMARY "%s outlet #%s load is not below the 'Low Load' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 25
outletLowLoadSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
DESCRIPTION
"MINOR: Outlet load had fallen below the 'Low Load' threshold
value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the outlet number."
--#SUMMARY "%s outlet #%s load has fallen below the 'Low Load' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY MINOR
::= 26
outletNearOverLoadCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Outlet load no longer exceeds the 'Near Over Load'
threshold value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the outlet number."
--#SUMMARY "%s outlet #%s load not over 'Near Over Load' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 27
outletNearOverLoadSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
DESCRIPTION
"MINOR: Outlet load has exceeded the 'Near Over Load' threshold
value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the outlet number."
--#SUMMARY "%s outlet #%s load is over 'Near Over Load' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY MINOR
::= 28
outletOverLoadCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Outlet load no longer exceeds the 'Over Load'
threshold value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the outlet number."
--#SUMMARY "%s outlet #%s load not over the 'Over Load' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 29
outletOverLoadSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
DESCRIPTION
"CRITICAL: Outlet load has exceeded the 'Over Load' threshold
value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the outlet number."
--#SUMMARY "%s outlet #%s load is over the 'Over Load' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY CRITICAL
::= 30
sensorDisconnectedCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Sensor disconnected condition cleared.
The first argument is the serial number.
The second argument is the device name.
The third argument is the sensor number."
--#SUMMARY "%s sensor #%s disconnected condition cleared."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 31
sensorDisconnectedSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
DESCRIPTION
"MINOR: Sensor disconnected condition set.
The first argument is the serial number.
The second argument is the device name.
The third argument is the sensor number."
--#SUMMARY "%s sensor #%s disconnected condition set."
--#ARGUMENTS {1,2}
--#SEVERITY MINOR
::= 32
sensorTypeIndeterminateCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Sensor type indeterminate condition cleared.
The first argument is the serial number.
The second argument is the device name.
The third argument is the sensor number."
--#SUMMARY "%s sensor #%s type indeterminate condition cleared."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 33
sensorTypeIndeterminateSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
DESCRIPTION
"MINOR: Sensor type indeterminate condition set.
The first argument is the serial number.
The second argument is the device name.
The third argument is the sensor number."
--#SUMMARY "%s sensor #%s type indeterminate condition set."
--#ARGUMENTS {1,2}
--#SEVERITY MINOR
::= 34
sensorTypeUnsupportedCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Sensor type unsupported condition cleared.
The first argument is the serial number.
The second argument is the device name.
The third argument is the sensor number."
--#SUMMARY "%s sensor #%s type unsupported condition cleared."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 35
sensorTypeUnsupportedSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
DESCRIPTION
"MINOR: Sensor type unsupported condition set.
The first argument is the serial number.
The second argument is the device name.
The third argument is the sensor number."
--#SUMMARY "%s sensor #%s type unsupported condition set."
--#ARGUMENTS {1,2}
--#SEVERITY MINOR
::= 36
maxTemperatureExceededCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Sensor Temperature no longer exceeds the
'Max Temperature' threshold value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the sensor number."
--#SUMMARY "%s sensor #%s temp not over 'Max Temperature' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 37
maxTemperatureExceededSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
DESCRIPTION
"CRITICAL: Sensor Temperature has exceeded the 'Max Temperature'
threshold value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the sensor number."
--#SUMMARY "%s sensor #%s temp is over 'Max Temperature' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY CRITICAL
::= 38
highTemperatureExceededCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Sensor Temperature no longer exceeds the 'High
Temperature' threshold value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the sensor number."
--#SUMMARY "%s sensor #%s temp below 'High Temperature' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 39
highTemperatureExceededSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
DESCRIPTION
"MINOR: Sensor Temperature has exceeded the 'High Temperature'
threshold value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the sensor number."
--#SUMMARY "%s sensor #%s temp over 'High Temperature' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY MINOR
::= 40
lowHumidityExceededCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Sensor Humidity is no longer below the 'Low
Humidity' threshold value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the sensor number."
--#SUMMARY "%s sensor #%s humidity is above 'Low Humidity' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 41
lowHumidityExceededSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
DESCRIPTION
"MINOR: Sensor Humidity has fallen below the 'Low Humidity'
threshold value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the sensor number."
--#SUMMARY "%s sensor #%s humidity is below 'Low Humidity' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY MINOR
::= 42
minHumidityExceededCleared TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Sensor Humidity is no longer below the 'Min
Humidity' threshold value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the sensor number."
--#SUMMARY "%s sensor #%s humidity is above 'Min Humidity' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 43
minHumidityExceededSet TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
DESCRIPTION
"CRITICAL: Sensor Humidity has fallen below the 'Min Humidity'
threshold value.
The first argument is the serial number.
The second argument is the device name.
The third argument is the sensor number."
--#SUMMARY "%s sensor #%s humidity is below 'Min Humidity' threshold."
--#ARGUMENTS {1,2}
--#SEVERITY CRITICAL
::= 44
outletTurnOn TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: An outlet has turned on.
The first argument is the serial number.
The second argument is the device name.
The third argument is the outlet number."
--#SUMMARY "%s outlet #%s has turned on."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 45
outletTurnOff TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: An outlet has turned off.
The first argument is the serial number.
The second argument is the device name.
The third argument is the outlet number."
--#SUMMARY "%s outlet #%s has turned off."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 46
actionCancelled TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: An outlet action has been cancelled.
The first argument is the serial number.
The second argument is the device name.
The third argument is the outlet number."
--#SUMMARY "%s outlet #%s action has been cancelled."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 47
deviceConfigurationChange TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: A device configuration has been changed.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s device configuration has been changed."
--#ARGUMENTS {1}
--#SEVERITY INFORMATIONAL
::= 48
sensorConfigurationChange TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: A sensor configuration has been changed.
The first argument is the serial number.
The second argument is the device name.
The third argument is the sensor number."
--#SUMMARY "%s sensor #%s configuration has been changed."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 49
outletConfigurationChange TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: An outlet configuration has been changed.
The first argument is the serial number.
The second argument is the device name.
The third argument is the outlet number."
--#SUMMARY "%s outlet #%s configuration has been changed."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 50
phaseConfigurationChange TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, phaseNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: A phase configuration has been changed.
The first argument is the serial number.
The second argument is the device name.
The third argument is the phase number."
--#SUMMARY "%s phase #%s configuration has been changed."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 51
dryContactConfigurationChange TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, contactNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: A dry contact configuration has been changed.
The first argument is the serial number.
The second argument is the device name.
The third argument is the contact number."
--#SUMMARY "%s dry contact #%s configuration has been changed."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 52
actionInit TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: An outlet action has been initialized.
The first argument is the serial number.
The second argument is the device name.
The third argument is the outlet number."
--#SUMMARY "%s outlet #%s action has been initialized."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 53
actionFailed TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
DESCRIPTION
"MINOR: An outlet action has failed to complete.
The first argument is the serial number.
The second argument is the device name.
The third argument is the outlet number."
--#SUMMARY "%s outlet #%s action has failed to complete."
--#ARGUMENTS {1,2}
--#SEVERITY MINOR
::= 54
actionDeleted TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: An outlet action has been deleted.
The first argument is the serial number.
The second argument is the device name.
The third argument is the outlet number."
--#SUMMARY "%s outlet #%s action has been deleted."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 55
syncCommandFailed TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, outletNumber, mtrapargsString }
DESCRIPTION
"MINOR: An outlet sync command to another unit has failed.
The first argument is the serial number.
The second argument is the device name.
The third argument is the outlet number."
--#SUMMARY "%s outlet #%s sync command to another unit has failed."
--#ARGUMENTS {1,2}
--#SEVERITY MINOR
::= 56
mPOPicFwDownloadStarted TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: MPO pic fw download started.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s MPO pic fw download started."
--#ARGUMENTS {1}
--#SEVERITY INFORMATIONAL
::= 57
mPOPicFwDownloadComplete TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: MPO pic fw download complete.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s MPO pic fw download complete."
--#ARGUMENTS {1}
--#SEVERITY INFORMATIONAL
::= 58
mPOPicFwDownloadAborted TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: MPO pic fw download aborted.
The first argument is the serial number.
The second argument is the device name."
--#SUMMARY "%s MPO pic fw download aborted."
--#ARGUMENTS {1}
--#SEVERITY INFORMATIONAL
::= 59
sensorCommEstablished TRAP-TYPE
ENTERPRISE events
VARIABLES { serialNumber, deviceNameD, sensorNumber, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Sensor comm established.
The first argument is the serial number.
The second argument is the device name.
The third argument is the sensor number."
--#SUMMARY "%s sensor #%s comm established."
--#ARGUMENTS {1,2}
--#SEVERITY INFORMATIONAL
::= 60
-- System generated traps
configChangeSNMP TRAP-TYPE
ENTERPRISE events
VARIABLES { mtrapargsString }
DESCRIPTION
"MINOR: The SNMP configuration has been changed."
--#SUMMARY "The SNMP configuration has been changed."
--#SEVERITY MINOR
::= 1000
accessViolationConsole TRAP-TYPE
ENTERPRISE events
VARIABLES { mtrapargsString }
DESCRIPTION
"MINOR: Someone attempted console login with incorrect password
three times."
--#SUMMARY "Three unsuccessful logins were attempted via the console."
--#SEVERITY MINOR
::= 1001
accessViolationHTTP TRAP-TYPE
ENTERPRISE events
VARIABLES { mtrapargsString }
DESCRIPTION
"MINOR: Someone attempted login via HTTP with incorrect password."
--#SUMMARY "An unsuccessful attempt to login via HTTP."
--#SEVERITY MINOR
::= 1002
dellTestTrap TRAP-TYPE
ENTERPRISE events
VARIABLES { testTrapargsInteger, mtrapargsString }
DESCRIPTION
"INFORMATIONAL: Trap used to test SNMP trap functionality.
The first argument is a place holder for test variables."
--#SUMMARY "Test Trap."
--#SEVERITY INFORMATIONAL
::= 1003
END