-- file: ORION-BASE-MIB.mib
|
||
|
||
ORION-BASE-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
DisplayString
|
||
FROM SNMPv2-TC
|
||
OBJECT-GROUP,
|
||
NOTIFICATION-GROUP,
|
||
MODULE-COMPLIANCE
|
||
FROM SNMPv2-CONF
|
||
modules,
|
||
orion
|
||
FROM GLOBAL-REG
|
||
enterprises,
|
||
MODULE-IDENTITY,
|
||
OBJECT-TYPE,
|
||
NOTIFICATION-TYPE,
|
||
Gauge32,
|
||
Integer32,
|
||
IpAddress
|
||
FROM SNMPv2-SMI;
|
||
|
||
orionBaseMibModule MODULE-IDENTITY
|
||
LAST-UPDATED "200802211439Z"
|
||
ORGANIZATION "Delta Energy Systems (Switzerland) AG"
|
||
CONTACT-INFO
|
||
"postal: Delta Energy Systems (Switzerland) AG
|
||
Freiburgstrasse 251,
|
||
CH-3018 Bern-Buempliz
|
||
web: www.deltapowersolutions.com
|
||
email: patrick.camina@delta-es.com"
|
||
DESCRIPTION
|
||
"MIB for managing a DC power system with PSC 3."
|
||
|
||
REVISION "201204271200Z"
|
||
DESCRIPTION
|
||
"Rev V5.0 - ORION V5.10
|
||
- Add Multi-Stage temperature compensation
|
||
- Add dcBoD and dcEnableUsTempComp"
|
||
|
||
REVISION "201201261415Z"
|
||
DESCRIPTION
|
||
"Rev V2.1 - ORION V5.0
|
||
- changed product name from PSC3 to Orion"
|
||
|
||
REVISION "201106200734Z"
|
||
DESCRIPTION
|
||
"Rev V2.0 - PSC 3 V3.20
|
||
- hour meter functionality added"
|
||
|
||
REVISION "201102100901Z"
|
||
DESCRIPTION
|
||
"Rev V1.9 - PSC 3 V3.10
|
||
- dcPowerSystem can be negativ now
|
||
- added limits for DefaultLog and EventProcessing table
|
||
- added dcResendActiveAlarmTraps in deschMiscGroup"
|
||
|
||
REVISION "201006161027Z"
|
||
DESCRIPTION
|
||
"Rev V1.8 - PSC 3 V2.70
|
||
- new rectifier types added
|
||
- resend active alarm traps feature added
|
||
- measurement table added
|
||
- battery test result enum extended"
|
||
|
||
REVISION "201002241046Z"
|
||
DESCRIPTION
|
||
"Rev V1.7 - PSC 3 V2.60
|
||
- Critical alarm trap added
|
||
- Float Charge, Battery Test, Equalize, Boost Charge,
|
||
,System Voltage Supervision and Event Control Charge
|
||
parameter added
|
||
- Rectifier Group table added
|
||
- Rectifier power limitation and efficiency cycling
|
||
parameter added
|
||
- LVD table added
|
||
- Default Log event configuration table added
|
||
- Event Processing event configuration table added
|
||
- Loss of Backup time parameter added"
|
||
|
||
REVISION "200909040952Z"
|
||
DESCRIPTION
|
||
"Rev V1.6 - PSC 3 V2.50
|
||
- Generic Alarm table added
|
||
- Trap Destination table added"
|
||
|
||
REVISION "200802211439Z"
|
||
DESCRIPTION
|
||
"Rev V1.5 - PSC V2.20
|
||
- support of write access
|
||
- added battery parameters"
|
||
|
||
REVISION "200801180835Z"
|
||
DESCRIPTION
|
||
"Rev V1.4 - PSC 3 V2.10
|
||
- added event controlled charge state"
|
||
|
||
REVISION "200607271026Z"
|
||
DESCRIPTION
|
||
"Rev V1.3 - PSC 3 V1.70
|
||
- corrected Oid comment for dcStartTemp, dcStopTemp
|
||
and dcTotalBatteryCapacity"
|
||
|
||
REVISION "200603020855Z"
|
||
DESCRIPTION
|
||
"Rev V1.2
|
||
- added various parameters.
|
||
- added additional TRAP parameter."
|
||
|
||
REVISION "200602230932Z"
|
||
DESCRIPTION
|
||
"Rev V1.1 - PSC 3 V1.60
|
||
- extended dcChargeState with new sepCharge state."
|
||
|
||
REVISION "200506031107Z"
|
||
DESCRIPTION
|
||
"Rev V1.0 - PSC 3 V1.5 and older
|
||
- added dcCurrentLimit parameter.
|
||
- renamed module.
|
||
- increased dcSoftwareVersion string size.
|
||
- added recharge state to dcChargeState parameter.
|
||
- added max. number of entries in comment for event history."
|
||
|
||
-- 1.3.6.1.4.1.20246.2.1.1.2 --
|
||
::= { modules 2 }
|
||
|
||
|
||
-- root for items in the controller MIB module
|
||
|
||
orionBaseMib OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1 --
|
||
::= { orion 1 }
|
||
|
||
-- conformance area, containing groups and compliance specifications
|
||
|
||
controllerConfs OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1 --
|
||
::= { orionBaseMib 1 }
|
||
|
||
controllerGroups OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1 --
|
||
::= { controllerConfs 1 }
|
||
|
||
controllerCompl OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.2 --
|
||
::= { controllerConfs 2 }
|
||
|
||
-- sub-tree for objects, and for each functional area
|
||
|
||
controllerObjects OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2 --
|
||
::= { orionBaseMib 2 }
|
||
|
||
dcSystemInfo OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.1 --
|
||
::= { controllerObjects 1 }
|
||
|
||
dcSystemAlarms OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2 --
|
||
::= { controllerObjects 2 }
|
||
|
||
dcSystemMonitor OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.3 --
|
||
::= { controllerObjects 3 }
|
||
|
||
dcRectifier OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4 --
|
||
::= { controllerObjects 4 }
|
||
|
||
dcRectifierFunctions OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6 --
|
||
::= { dcRectifier 6 }
|
||
|
||
dcEfficiencyCycling OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.1 --
|
||
::= { dcRectifierFunctions 1 }
|
||
|
||
dcPowerLimitation OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.2 --
|
||
::= { dcRectifierFunctions 2 }
|
||
|
||
dcBattery OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5 --
|
||
::= { controllerObjects 5 }
|
||
|
||
dcFloatCharge OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.1 --
|
||
::= { dcBattery 1 }
|
||
|
||
dcBatteryTest OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2 --
|
||
::= { dcBattery 2 }
|
||
|
||
dcBatteryTestParameter OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1 --
|
||
::= { dcBatteryTest 1 }
|
||
|
||
dcBatteryTestResults OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.2 --
|
||
::= { dcBatteryTest 2 }
|
||
|
||
dcBatteryParameter OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3 --
|
||
::= { dcBattery 3 }
|
||
|
||
dcLossOfBackupTime OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.3 --
|
||
::= { dcBatteryParameter 3 }
|
||
|
||
dcEqualize OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4 --
|
||
::= { dcBattery 4 }
|
||
|
||
dcEqualizeParameter OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4 --
|
||
::= { dcEqualize 4 }
|
||
|
||
dcBoostCharge OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5 --
|
||
::= { dcBattery 5 }
|
||
|
||
dcBoostChargeParameter OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.4 --
|
||
::= { dcBoostCharge 4 }
|
||
|
||
dcSystemVoltageSupervision OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6 --
|
||
::= { dcBattery 6 }
|
||
|
||
dcEvtCtrlCharge OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7 --
|
||
::= { dcBattery 7 }
|
||
|
||
dcEvtCtrlChargeParameter OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.3 --
|
||
::= { dcEvtCtrlCharge 3 }
|
||
|
||
dcTempComp OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8 --
|
||
::= { dcBattery 8 }
|
||
|
||
dcTempSupervision OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.9 --
|
||
::= { dcBattery 9 }
|
||
|
||
dcInputOutput OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.6 --
|
||
::= { controllerObjects 6 }
|
||
|
||
dcMisc OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.7 --
|
||
::= { controllerObjects 7 }
|
||
|
||
dcConfig OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.8 --
|
||
::= { controllerObjects 8 }
|
||
|
||
dcMeasurement OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.9 --
|
||
::= { controllerObjects 9 }
|
||
|
||
dcMeterPanel OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.10 --
|
||
::= { controllerObjects 10 }
|
||
|
||
-- sub-tree for notifications
|
||
controllerEvents OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.3 --
|
||
::= { orionBaseMib 3 }
|
||
|
||
controllerEventObjects OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.3.1 --
|
||
::= { controllerEvents 1 }
|
||
|
||
-- The following OBJECT IDENTIFIER is used to define SNMPv2 notifications
|
||
-- that are backward compatible with SNMPv1 traps
|
||
controllerEventsV2 OBJECT IDENTIFIER
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.3.1.0 --
|
||
::= { controllerEventObjects 0 }
|
||
|
||
-- ================================
|
||
-- Scalar objects
|
||
-- ================================
|
||
dcSiteName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An administratively-assigned site name for this
|
||
DC-power system."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.1.1 --
|
||
::= { dcSystemInfo 1 }
|
||
|
||
dcSystemName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An administratively-assigned system name for this
|
||
DC-power system."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.1.2 --
|
||
::= { dcSystemInfo 2 }
|
||
|
||
dcSystemDateTime OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (19))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"ISO 8601 representation of controller<65>s local date/time.
|
||
The value is in the format YYYY-MM-DDThh:mm:ss.
|
||
An example of a valid string is: '2004-10-04T13:45:00'."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.1.3 --
|
||
::= { dcSystemInfo 3 }
|
||
|
||
dcSoftwareVersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (10..12))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The controller<65>s software version e.g V2.50Build1."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.1.4 --
|
||
::= { dcSystemInfo 4 }
|
||
|
||
dcNumberUrgentAlarms OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Number of currently active urgent alarm sources. A zero
|
||
value indicates that urgent alarm is not active."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.3 --
|
||
::= { dcSystemAlarms 3 }
|
||
|
||
dcNumberNonUrgentAlarms OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Number of currently active non urgent alarm sources. A zero
|
||
value indicates that non urgent alarm is not active."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.4 --
|
||
::= { dcSystemAlarms 4 }
|
||
|
||
dcMainsFailureAlarm OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
inactive(1),
|
||
active(2) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Mains failure alarm."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.5 --
|
||
::= { dcSystemAlarms 5 }
|
||
|
||
dcUrgentAlarmIdentifier OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current unique urgent alarm event identifier. A zero value
|
||
indicates that urgent alarm is not active."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.6 --
|
||
::= { dcSystemAlarms 6 }
|
||
|
||
dcUrgentAlarmValue OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
false(1),
|
||
indeterminate(2), -- deprecated, not used anymore
|
||
true(3) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current urgent alarm event status that corresponds to the
|
||
urgent alarm identifier. If the urgent alarm identifier is zero
|
||
then the alarm value is false."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.7 --
|
||
::= { dcSystemAlarms 7 }
|
||
|
||
dcNonUrgentAlarmIdentifier OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current unique non urgent alarm event identifier. A zero value
|
||
indicates that non urgent alarm is not active."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.8 --
|
||
::= { dcSystemAlarms 8 }
|
||
|
||
dcNonUrgentAlarmValue OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
false(1),
|
||
indeterminate(2), -- deprecated, not used anymore
|
||
true(3) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current non urgent alarm event status that corresponds to non urgent
|
||
alarm identifier. If the non urgent alarm identifier is zero then
|
||
the alarm value is false."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.9 --
|
||
::= { dcSystemAlarms 9 }
|
||
|
||
dcUrgentAlarmName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..35))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current alarm name for urgent alarm that corresponds to urgent
|
||
alarm identifier."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.10 --
|
||
::= { dcSystemAlarms 10 }
|
||
|
||
dcNonUrgentAlarmName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..35))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current alarm name for active non urgent alarm that corresponds
|
||
to non urgent alarm identifier."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.11 --
|
||
::= { dcSystemAlarms 11 }
|
||
|
||
dcNumberCriticalAlarms OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Number of currently active critical alarm sources. A zero
|
||
value indicates that critical alarm is not active."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.13 --
|
||
::= { dcSystemAlarms 13 }
|
||
|
||
dcCriticalAlarmIdentifier OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current unique critical alarm event identifier. A zero value
|
||
indicates that critical alarm is not active."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.14 --
|
||
::= { dcSystemAlarms 14 }
|
||
|
||
dcCriticalAlarmValue OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
false(1),
|
||
indeterminate(2), -- deprecated, not used anymore
|
||
true(3) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current critical alarm event status that corresponds to the
|
||
critical alarm identifier. If the critical alarm identifier is zero
|
||
then the alarm value is false."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.15 --
|
||
::= { dcSystemAlarms 15 }
|
||
|
||
dcCriticalAlarmName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..35))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current alarm name for active critical alarm that corresponds
|
||
to critical alarm identifier."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.16 --
|
||
::= { dcSystemAlarms 16 }
|
||
|
||
dcSystemVoltage OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The measured system voltage. The max. value 2147483647
|
||
is used to indicate an invalid value."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.3.1 --
|
||
::= { dcSystemMonitor 1 }
|
||
|
||
dcLoadCurrent OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "100 mA"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The measured load current. The max. value 2147483647
|
||
is used to indicate an invalid value."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.3.2 --
|
||
::= { dcSystemMonitor 2 }
|
||
|
||
dcBatteryCurrent OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "100 mA"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The measured battery current. The max. value 2147483647
|
||
is used to indicate an invalid value."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.3.3 --
|
||
::= { dcSystemMonitor 3 }
|
||
|
||
dcBatteryTemperature OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "0.1 <20>C"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The measured battery temperature. The max. value 2147483647
|
||
is used to indicate an invalid value."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.3.4 --
|
||
::= { dcSystemMonitor 4 }
|
||
|
||
dcChargeState OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
float(1),
|
||
discharge(2),
|
||
equalize(3),
|
||
boost(4),
|
||
battTest(5),
|
||
recharge(6),
|
||
sepCharge(7),
|
||
evCtrlCharge(8) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Battery charge state."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.3.5 --
|
||
::= { dcSystemMonitor 5 }
|
||
|
||
dcCurrentLimit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
inactive(1),
|
||
active(2) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Battery current limit."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.3.6 --
|
||
::= { dcSystemMonitor 6 }
|
||
|
||
dcRectifierCurrent OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "100 mA"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Total current of all working rectifier modules.
|
||
The maximum value 2147483647 is used to indicate
|
||
an invalid value."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.3.7 --
|
||
::= { dcSystemMonitor 7 }
|
||
|
||
dcSystemPower OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "1 W"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Calculated system power. The maximum value
|
||
2147483647 is used to indicate an invalid value."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.3.8 --
|
||
::= { dcSystemMonitor 8 }
|
||
|
||
-- Rectifier
|
||
dcNumberRectifiers OBJECT-TYPE
|
||
SYNTAX Gauge32 (0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The configured number of rectifiers plugged into
|
||
the system. The maximum number of rectifiersi is 128."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.1 --
|
||
::= { dcRectifier 1 }
|
||
|
||
dcNumberRectifiersFailure OBJECT-TYPE
|
||
SYNTAX Gauge32 (0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Number of rectifiers that are not properly working."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.2 --
|
||
::= { dcRectifier 2 }
|
||
|
||
dcNumberRectifiersOkay OBJECT-TYPE
|
||
SYNTAX Gauge32 (0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Number of rectifiers that are properly working."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.3 --
|
||
::= { dcRectifier 3 }
|
||
|
||
-- Rectifier - RectifierFunctions - EfficiencyCycling
|
||
dcEfficiencyCyclingEnabled OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(1),
|
||
yes(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/disable efficiency cycling."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.1.1 --
|
||
::= { dcEfficiencyCycling 1 }
|
||
|
||
dcLimitSwitchingTimes OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(1),
|
||
yes(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/disable limit switching times."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.1.2 --
|
||
::= { dcEfficiencyCycling 2 }
|
||
|
||
dcForceSwitchingOncePerMonth OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(1),
|
||
yes(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/disable force switching once per month."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.1.3 --
|
||
::= { dcEfficiencyCycling 3 }
|
||
|
||
dcMaximumLoadStep OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "1 W"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum load setup."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.1.4 --
|
||
::= { dcEfficiencyCycling 4 }
|
||
|
||
dcMinimumLoadStep OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "1 W"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Minimum load setup."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.1.5 --
|
||
::= { dcEfficiencyCycling 5 }
|
||
|
||
-- Battery - FloatCharge
|
||
dcUsys20 OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Voltage to regulate to at 20<32>C. If temperature compensation
|
||
is used, this voltage will vary."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.1.1 --
|
||
::= { dcFloatCharge 1 }
|
||
|
||
|
||
-- Battery - BatteryTest - BatteryTestParameter
|
||
dcBatteryTestUsupport OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Support charge voltage for the battery."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.1 --
|
||
::= { dcBatteryTestParameter 1 }
|
||
|
||
dcBatteryTestDuration OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "minute"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Battery test duration."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.2 --
|
||
::= { dcBatteryTestParameter 2 }
|
||
|
||
dcBatteryTestInterval OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "days"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Minimal time between programmed battery tests as start
|
||
condition."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.3 --
|
||
::= { dcBatteryTestParameter 3 }
|
||
|
||
dcBatteryTestDischargeCurrent OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "100 mA"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Battery discharge current. The maximum value 2147483647
|
||
is used to indicate an invalid value."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.4 --
|
||
::= { dcBatteryTestParameter 4 }
|
||
|
||
dcBatteryTestMinDuration OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "minutes"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Minimum battery test duration during which time a battery test
|
||
is not stopped in case of a voltage below the support voltage or
|
||
a current difference higher than the specified value defined in
|
||
Idiff measurement is detected."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.5 --
|
||
::= { dcBatteryTestParameter 5 }
|
||
|
||
dcBatteryTestVoltageWithinUfloat OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Battery voltage must be within Ufloat +/- set voltage for a
|
||
given time (see also dcBatteryTestVoltageWithinUfloatPeriod)
|
||
in order to start a battery test."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.6 --
|
||
::= { dcBatteryTestParameter 6 }
|
||
|
||
dcBatteryTestVoltageWithinUfloatPeriod OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "days"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For details see dcBatteryTestVoltageWithinUfloat parameter."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.7 --
|
||
::= { dcBatteryTestParameter 7 }
|
||
|
||
dcBatteryTestTempFrom OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "0.1 <20>C"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Battery temperature must be within temperature range given by
|
||
dcBatteryTestTempFrom and dcBatteryTestTempTo, so that a battery
|
||
test can be started."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.8 --
|
||
::= { dcBatteryTestParameter 8 }
|
||
|
||
dcBatteryTestTempTo OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "0.1 <20>C"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For details see dcBatteryTestTempFrom parameter."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.9 --
|
||
::= { dcBatteryTestParameter 9 }
|
||
|
||
dcBatteryTestIntervalEnabled OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(1),
|
||
yes(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/disable interval. For more details see dcBatteryTestInterval."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.1.10 --
|
||
::= { dcBatteryTestParameter 10 }
|
||
|
||
dcBatteryTestStartTimeFrom OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (8))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Defines start time window for battery test. The possible time window
|
||
is defined as the range between dcBatteryTestStartTimeFrom and
|
||
dcBatteryTestStartTimeTo. The value is in the format 'hh:mm:ss'."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.11 --
|
||
::= { dcBatteryTestParameter 11 }
|
||
|
||
dcBatteryTestStartTimeTo OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (8))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For details see dcBatteryTestStartTimeFrom."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.12 --
|
||
::= { dcBatteryTestParameter 12 }
|
||
|
||
-- Battery - BatteryTest - BatteryTestResults
|
||
dcBatteryTestDateTime OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (19))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"ISO 8601 representation of the last performed battery test.
|
||
The value is in the format YYYY-MM-DDThh:mm:ss. This parameter
|
||
is valid only if there is a test result available."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.2.1 --
|
||
::= { dcBatteryTestResults 1 }
|
||
|
||
dcBatteryTestResult OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
none(1),
|
||
failed(2),
|
||
aborted(3),
|
||
loadFailure(4),
|
||
okay(5),
|
||
abortedManual(6),
|
||
abortedEvCtrlCharge(7),
|
||
abortedInhibitEv(8) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Result of last performed battery test."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.2.2 --
|
||
::= { dcBatteryTestResults 2 }
|
||
|
||
dcBatteryTestEndVoltage OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"System voltage at the end of the last performed battery test.
|
||
The maximum value 2147483647 is used to indicate an invalid
|
||
value."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.2.3 --
|
||
::= { dcBatteryTestResults 3 }
|
||
|
||
dcBatteryTestControl OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
start(1),
|
||
stop(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Start/stop of battery test. This special charge mode is used
|
||
to check the capacity of a battery. Please note that a battery
|
||
test can be started even if the battery is not fully charged.
|
||
In this case the test result is ambiguous and the set failure
|
||
event will become active."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.3 --
|
||
::= { dcBatteryTest 3 }
|
||
|
||
dcBatteryTestStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
inactive(1),
|
||
starting(2),
|
||
stopping(3),
|
||
constantCurrent(4),
|
||
timeBased(5),
|
||
energyBased(6),
|
||
recovery(7),
|
||
realLoad(8),
|
||
stop(9) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Status of battery test."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.4 --
|
||
::= { dcBatteryTest 4 }
|
||
|
||
dcBatteryTestFailureEvent OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
reset(1) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reset battery test failure event."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.5 --
|
||
::= { dcBatteryTest 5 }
|
||
|
||
dcBatteryTestType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
none(1),
|
||
constantCurrent(2),
|
||
--timeBased(3), deprecated --
|
||
--energyBased(4), deprecated --
|
||
realLoad(5) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Battery test type used."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.6 --
|
||
::= { dcBatteryTest 6 }
|
||
|
||
-- Battery - BatteryParameter
|
||
dcTotalBatteryCapacity OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "100 mAh"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Total battery capacity for all available batteries."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.1 --
|
||
::= { dcBatteryParameter 1 }
|
||
|
||
-- Battery - BatteryParameter - LossOfBackupTime
|
||
dcLossOfBackupTimeEnabled OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(1),
|
||
yes(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/disable loss of backup time functionality."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.3.1 --
|
||
::= { dcLossOfBackupTime 1 }
|
||
|
||
dcLossOfBackupTimeStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
inactive(1),
|
||
ok(2),
|
||
occured(3),
|
||
fail(4) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Status of loss of backup time functionality."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.3.2 --
|
||
::= { dcLossOfBackupTime 2 }
|
||
|
||
dcExpectedBackupTime OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "minutes"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Expected backup time value. Based on the given value for
|
||
the parameter expected backup time, the corresponding
|
||
maximum discharge current is calculated."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.3.3 --
|
||
::= { dcLossOfBackupTime 3 }
|
||
|
||
-- Battery - Equalize
|
||
dcEqualizeControl OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
start(1),
|
||
stop(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Start/stop of battery equalize which is a special charge
|
||
mode that applies a higher voltage to the batteries than
|
||
the float charge. This ensures that the cells are all
|
||
equally charged."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.1 --
|
||
::= { dcEqualize 1 }
|
||
|
||
dcEqualizeStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
inactive(1),
|
||
starting(2),
|
||
stopping(3),
|
||
preparing(4),
|
||
cooking(5),
|
||
recovering(6) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current status of battery equalize."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.2 --
|
||
::= { dcEqualize 2 }
|
||
|
||
dcEqualizeEnabled OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(1),
|
||
yes(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/disable equalize."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.3 --
|
||
::= { dcEqualize 3 }
|
||
|
||
-- Equalize - EqualizeParameter
|
||
dcEqualizeVoltage OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Voltage used for equalize."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4.1 --
|
||
::= { dcEqualizeParameter 1 }
|
||
|
||
dcEqualizeDuration OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "minutes"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Duration of equalize."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4.2 --
|
||
::= { dcEqualizeParameter 2 }
|
||
|
||
dcEqualizeUseBattRoomFanEnabled OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(1),
|
||
yes(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/disable battery room fan during equalize."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4.3 --
|
||
::= { dcEqualizeParameter 3 }
|
||
|
||
dcEqualizeLeadTime OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "minutes"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Lead time for equalize."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4.4 --
|
||
::= { dcEqualizeParameter 4 }
|
||
|
||
dcEqualizeTimeLag OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "minutes"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Time lag for equalize."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4.5 --
|
||
::= { dcEqualizeParameter 5 }
|
||
|
||
dcEqualizeInterval OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "days"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Interval for equalize as start condition."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4.6 --
|
||
::= { dcEqualizeParameter 6 }
|
||
|
||
dcEqualizeStartTimeIntervalFrom OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (8))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Defines start time window for equqlize. The possible time window
|
||
is defined as the range between dcEqualizeStartTimeIntervalFrom and
|
||
dcEqualizeStartTimeIntervalTo. The value is in the format 'hh:mm:ss'."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4.7 --
|
||
::= { dcEqualizeParameter 7 }
|
||
|
||
dcEqualizeStartTimeIntervalTo OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (8))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For detail see dcEqualizeStartTimeIntervalFrom."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4.8 --
|
||
::= { dcEqualizeParameter 8 }
|
||
|
||
dcEqualizeInhibitAfterBoost OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "hours"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Inhibit after boost as start condition."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.4.4.9 --
|
||
::= { dcEqualizeParameter 9 }
|
||
|
||
-- Battery - BoostCharge
|
||
dcBoostChargeControl OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
start(1),
|
||
stop(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Start/stop of boost charge which is a special charge mode
|
||
that applies a higher voltage to the batteries than the float
|
||
charge. This mode is started after a discharge phase to
|
||
recharge the batteries faster."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.1 --
|
||
::= { dcBoostCharge 1 }
|
||
|
||
dcBoostChargeStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
inactive(1),
|
||
starting(2),
|
||
stopping(3),
|
||
cooking(4),
|
||
recovering(5) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current status of boost charge."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.2 --
|
||
::= { dcBoostCharge 2 }
|
||
|
||
dcBoostChargeType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
none(1),
|
||
currentBased(2),
|
||
timeBased(3),
|
||
energyBased(4) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Boost charge type."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.3 --
|
||
::= { dcBoostCharge 3 }
|
||
|
||
-- Battery - BoostCharge - BoostChargeParameter
|
||
dcBoostChargeVoltage OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Voltage used for boost charge."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.2.1 --
|
||
::= { dcBoostChargeParameter 1 }
|
||
|
||
dcBoostChargeMaxDuration OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "hours"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Defines the maximum allowed time for boost charge to
|
||
prevent that the battery is charged forever."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.2.2 --
|
||
::= { dcBoostChargeParameter 2 }
|
||
|
||
dcBoostChargeUseBattRoomFanEnabled OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(1),
|
||
yes(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/disable battery room fan during boost charge."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.2.3 --
|
||
::= { dcBoostChargeParameter 3 }
|
||
|
||
dcBoostChargeTimeLag OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "minutes"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Time lag used for boost charge."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.2.4 --
|
||
::= { dcBoostChargeParameter 4 }
|
||
|
||
dcBoostChargeIstart OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "100 mA"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For current based boost charge, the parameters Istart
|
||
and Istop are the battery current values at which boost charge
|
||
starts or stops."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.2.5 --
|
||
::= { dcBoostChargeParameter 5 }
|
||
|
||
dcBoostChargeIstop OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "100 mA"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For details see dcBoostChargeIstart."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.2.6 --
|
||
::= { dcBoostChargeParameter 6 }
|
||
|
||
dcBoostChargeInhibitTime OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "hours"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A start condition for all types of boost charge. It defines
|
||
the time from last boost charge stop to the next acceptable boost
|
||
charge start."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.5.2.7 --
|
||
::= { dcBoostChargeParameter 7 }
|
||
|
||
-- Battery - SystemVoltageSupervision
|
||
dcUaMax OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If the system voltage is outside the range specified by the values
|
||
UaMin (lower alarm voltage)/UaMax (upper alarm voltage), the
|
||
system event 'S Ua low'/'S Ua high' is activated. The values for the
|
||
parameters UaMin and UaMax are not temperature compensated."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6.1 --
|
||
::= { dcSystemVoltageSupervision 1 }
|
||
|
||
dcUaMin OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For details see dcUaMax."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6.2 --
|
||
::= { dcSystemVoltageSupervision 2 }
|
||
|
||
dcUsMax OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If the voltage is outside the range defined by the parameters UsMin (lower
|
||
safety voltage)/UsMax (upper safety voltage), the system event
|
||
'S Us low'/'S Us high' is activated. If temperature compensation is enabled,
|
||
the levels for Us min and / Us max are automatically temperature compensated
|
||
to correspond to the required system voltage. The parameters are defined
|
||
at 20<32>C."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6.3 --
|
||
::= { dcSystemVoltageSupervision 3 }
|
||
|
||
dcUsMin OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For details see dcUsMax."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6.4 --
|
||
::= { dcSystemVoltageSupervision 4 }
|
||
|
||
dcBoD OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Voltage threshold for Battery on Discharge alarm."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6.5 --
|
||
::= { dcSystemVoltageSupervision 5 }
|
||
|
||
dcHysteresis OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Hysteresis used for Ua and Us."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6.6 --
|
||
::= { dcSystemVoltageSupervision 6 }
|
||
|
||
dcSuppressUaLowEnabled OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(1),
|
||
yes(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Suppress Ua Low alarm during mains failure."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6.7 --
|
||
::= { dcSystemVoltageSupervision 7 }
|
||
|
||
dcSuppressUsLowEnabled OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(1),
|
||
yes(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Suppress Us Low alarm during mains failure."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6.8 --
|
||
::= { dcSystemVoltageSupervision 8 }
|
||
|
||
dcEnableUsTempComp OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(1),
|
||
yes(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Checkbox to enable the automatic temperature compensation for the Us thresholds (Us min, Us max)."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.6.9 --
|
||
::= { dcSystemVoltageSupervision 9 }
|
||
|
||
-- Battery - EvtCtrlCharge
|
||
dcEvtCtrlChargeStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
inactive(1),
|
||
voltageControlled(2),
|
||
noBatteryCharge(3),
|
||
currentLimitation(4) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Event control charge status."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.1 --
|
||
::= { dcEvtCtrlCharge 1 }
|
||
|
||
dcEvtCtrlChargeType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
none(1),
|
||
voltageControlled(2),
|
||
noBatteryCharge(3),
|
||
currentLimitation(4) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Selected event control charge type."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.2 --
|
||
::= { dcEvtCtrlCharge 2 }
|
||
|
||
dcEvtCtrlChargeVoltage OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Voltage used for event control charge."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.1.1 --
|
||
::= { dcEvtCtrlChargeParameter 1}
|
||
|
||
dcEvtCtrlChargeTempCompEnabled OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(1),
|
||
yes(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/disable temperature compensation during event
|
||
control charge."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.1.2 --
|
||
::= { dcEvtCtrlChargeParameter 2 }
|
||
|
||
dcEvtCtrlChargeMaxIBatt OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "100 mA"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Max. IBatt used for event control charge."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.7.1.3 --
|
||
::= { dcEvtCtrlChargeParameter 3}
|
||
|
||
dcTempCompType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(1),
|
||
linear(2),
|
||
multi-stage(3) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/disable battery temperature compensation."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.1 --
|
||
::= { dcTempComp 1 }
|
||
|
||
dcSlope OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "-1 mV/<2F>C"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Temperature compensation coefficient for system voltage."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.2 --
|
||
::= { dcTempComp 2 }
|
||
|
||
dcStartTemp OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "0.1 <20>C"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Lower limit for the area in which the temperature compensation
|
||
is active."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.3 --
|
||
::= { dcTempComp 3 }
|
||
|
||
dcStopTemp OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "0.1 <20>C"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Upper limit for the area in which the temperature compensation
|
||
is active."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.4 --
|
||
::= { dcTempComp 4 }
|
||
|
||
dcMaxVoltage OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Upper limit for the area in which the temperature compensation
|
||
is not controlling the system voltage."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.5 --
|
||
::= { dcTempComp 5 }
|
||
|
||
dcLowStopVoltage OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The temperature compensation will not control the charging voltage above this parameter at low temperatures."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.6 --
|
||
::= { dcTempComp 6 }
|
||
|
||
dcLowStartTemp OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "0.1 <20>C"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"High temperature limit of the lower range."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.7 --
|
||
::= { dcTempComp 7 }
|
||
|
||
dcLowTempSlope OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "-1 mV/<2F>C"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Compensation factor applied inside the low range."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.8 --
|
||
::= { dcTempComp 8 }
|
||
|
||
dcHighStartTemp OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "0.1 <20>C"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The low temperature limit of the higher range."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.9 --
|
||
::= { dcTempComp 9 }
|
||
|
||
dcHighTempSlope OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "-1 mV/<2F>C"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Compensation factor applied inside the high range."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.10 --
|
||
::= { dcTempComp 10 }
|
||
|
||
dcHighStopVoltage OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The temperature compensation will not control the charging voltage below this parameter at high temperatures."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.11 --
|
||
::= { dcTempComp 11 }
|
||
|
||
dcRunawayTemp OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "0.1 <20>C"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A threshold for detecting thermal runaway of the battery."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.12 --
|
||
::= { dcTempComp 12 }
|
||
|
||
dcRunawayVoltage OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Charging voltage while Runaway Temp has been exceeded."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.8.13 --
|
||
::= { dcTempComp 13 }
|
||
|
||
dcHighTemp OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "0.1 <20>C"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Temperature threshold for high battery temperature alarm 10<31>C ... 70<37>C"
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.9.1 --
|
||
::= { dcTempSupervision 1 }
|
||
|
||
dcHighTempHyst OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "0.1 <20>C"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Hysteresis for the High Temp 1<>C ... 70<37>C"
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.9.2 --
|
||
::= { dcTempSupervision 2 }
|
||
|
||
-- Misc
|
||
dcFileProcessingStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
idle(1),
|
||
inProgress(2),
|
||
successful(3),
|
||
error(4),
|
||
unknown(5) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"File processing status for software and setup up/downloads."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.2 --
|
||
::= { dcMisc 2 }
|
||
|
||
dcResendActiveAlarmTraps OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
resend(1) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Resend all active Urgent, Non Urgent, and Critical Alarm Traps."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.4 --
|
||
::= { dcMisc 4 }
|
||
|
||
-- Event Processing Table
|
||
dcEventProcessingEventSelected OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reference to dcEventProcessingEventIndex in order to select
|
||
a specific event."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.3 --
|
||
::= { dcConfig 3 }
|
||
|
||
-- ====================================================================
|
||
-- Event History table
|
||
-- ====================================================================
|
||
dcEventHistoryTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF DcEventHistoryEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Controller<65>s event history table that shows the content of the
|
||
default log file."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.1 --
|
||
::= { dcSystemAlarms 1 }
|
||
|
||
dcEventHistoryEntry OBJECT-TYPE
|
||
SYNTAX DcEventHistoryEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A particular Event History entry."
|
||
INDEX { dcEventHistoryIndex }
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.1.1 --
|
||
::= { dcEventHistoryTable 1 }
|
||
|
||
DcEventHistoryEntry ::= SEQUENCE {
|
||
|
||
dcEventHistoryIndex Integer32,
|
||
dcEventHistoryTimestamp DisplayString,
|
||
dcEventHistoryMessage DisplayString }
|
||
|
||
dcEventHistoryIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..10000)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table index."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.1.1.1 --
|
||
::= { dcEventHistoryEntry 1 }
|
||
|
||
dcEventHistoryTimestamp OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (19))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"ISO8601 timestamp representation of a particular entry
|
||
in the form YYYY-MM-DDThh:mm:ss."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.1.1.2 --
|
||
::= { dcEventHistoryEntry 2 }
|
||
|
||
dcEventHistoryMessage OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (1..255))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Event message of a particular entry."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.1.1.3 --
|
||
::= { dcEventHistoryEntry 3 }
|
||
|
||
|
||
-- ====================================================================
|
||
-- Active Alarm table
|
||
-- ====================================================================
|
||
dcAlarmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF DcAlarmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table that shows all currently active alarm sources
|
||
causing urgent or non-urgent alarm(s)."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.2 --
|
||
::= { dcSystemAlarms 2 }
|
||
|
||
dcAlarmEntry OBJECT-TYPE
|
||
SYNTAX DcAlarmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A particular active alarm source entry."
|
||
INDEX { dcAlarmIndex }
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.2.1 --
|
||
::= { dcAlarmTable 1 }
|
||
|
||
DcAlarmEntry ::= SEQUENCE {
|
||
dcAlarmIndex Integer32,
|
||
dcAlarmEventCategory INTEGER,
|
||
dcAlarmEventName DisplayString,
|
||
dcAlarmEventIdentifier Gauge32,
|
||
dcAlarmEventValue INTEGER }
|
||
|
||
dcAlarmIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..16)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table index."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.2.1.1 --
|
||
::= { dcAlarmEntry 1 }
|
||
|
||
dcAlarmEventCategory OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(1),
|
||
urgent(2),
|
||
nonUrgent(3),
|
||
critical(4) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Specifies the type of alarm source."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.2.1.2 --
|
||
::= { dcAlarmEntry 2 }
|
||
|
||
dcAlarmEventName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (1..35))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Name of a particular alarm source entry."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.2.1.3 --
|
||
::= { dcAlarmEntry 3 }
|
||
|
||
dcAlarmEventIdentifier OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Unique alarm event identifier."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.2.1.4 --
|
||
::= { dcAlarmEntry 4 }
|
||
|
||
dcAlarmEventValue OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
false(1),
|
||
-- indeterminate(2), deprecated --
|
||
true(3) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Event status that corresponds to alarm event identifier."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.2.1.5 --
|
||
::= { dcAlarmEntry 5 }
|
||
|
||
-- ====================================================================
|
||
-- Generic Alarm table
|
||
-- ====================================================================
|
||
dcGenericAlarmTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF DcGenericAlarmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table that shows ten alarm event assignments that can be
|
||
configured via WEB interface."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.12 --
|
||
::= { dcSystemAlarms 12 }
|
||
|
||
dcGenericAlarmEntry OBJECT-TYPE
|
||
SYNTAX DcGenericAlarmEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A particular generic alarm entry."
|
||
INDEX { dcGenericAlarmIndex }
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.12.1 --
|
||
::= { dcGenericAlarmTable 1 }
|
||
|
||
DcGenericAlarmEntry ::= SEQUENCE {
|
||
dcGenericAlarmIndex Integer32,
|
||
dcGenericAlarmEventName DisplayString,
|
||
dcGenericAlarmEventIdentifier Gauge32,
|
||
dcGenericAlarmEventValue INTEGER }
|
||
|
||
dcGenericAlarmIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..16)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table index."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.12.1.1 --
|
||
::= { dcGenericAlarmEntry 1 }
|
||
|
||
dcGenericAlarmEventName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..35))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Plain text name of the assigned alarm event. Empty if not
|
||
configured."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.12.1.2 --
|
||
::= { dcGenericAlarmEntry 2 }
|
||
|
||
dcGenericAlarmEventIdentifier OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Unique numeric identifier of the assigned alarm event. Zero
|
||
if not configured."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.12.1.3 --
|
||
::= { dcGenericAlarmEntry 3 }
|
||
|
||
dcGenericAlarmEventValue OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
false(1),
|
||
true(2) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current value of the assigned alarm event. Value is false if
|
||
not configured."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.2.12.1.4 --
|
||
::= { dcGenericAlarmEntry 4 }
|
||
|
||
-- ====================================================================
|
||
-- Rectifier table
|
||
-- ====================================================================
|
||
dcRectifierTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF DcRectifierEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table that shows all currently active rectifier modules."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.4 --
|
||
::= { dcRectifier 4 }
|
||
|
||
dcRectifierEntry OBJECT-TYPE
|
||
SYNTAX DcRectifierEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A particular rectifier entry."
|
||
INDEX { dcRectifierIndex }
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.4.1 --
|
||
::= { dcRectifierTable 1 }
|
||
|
||
DcRectifierEntry ::= SEQUENCE {
|
||
dcRectifierIndex Integer32,
|
||
dcRectifierIdentifier DisplayString,
|
||
dcRectifierStatus INTEGER }
|
||
|
||
dcRectifierIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..128)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table index."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.4.1.1 --
|
||
::= { dcRectifierEntry 1 }
|
||
|
||
dcRectifierIdentifier OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (1..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Unique rectifier identifier. If positioning active the
|
||
position number scheme is used otherwise the rectifier
|
||
instance is used to identify a rectifier."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.4.1.2 --
|
||
::= { dcRectifierEntry 2 }
|
||
|
||
dcRectifierStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(1),
|
||
off(2),
|
||
on(3) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Specifies status of rectifiers."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.4.1.3 --
|
||
::= { dcRectifierEntry 3 }
|
||
|
||
-- ====================================================================
|
||
-- Rectifier Group table
|
||
-- ====================================================================
|
||
dcRectifierGroupTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF DcRectifierGroupEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table that shows all available rectifier groups."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5 --
|
||
::= { dcRectifier 5 }
|
||
|
||
dcRectifierGroupEntry OBJECT-TYPE
|
||
SYNTAX DcRectifierGroupEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A particular rectifier group entry."
|
||
INDEX { dcRectifierGroupIndex }
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1 --
|
||
::= { dcRectifierGroupTable 1 }
|
||
|
||
DcRectifierGroupEntry ::= SEQUENCE {
|
||
dcRectifierGroupIndex Integer32,
|
||
dcRectifierGroupName DisplayString,
|
||
dcRectifierGroupRectifierType INTEGER,
|
||
dcRectifierGroupDefaultVoltage Integer32,
|
||
dcRectifierGroupDefaultCurrentLimit Integer32,
|
||
dcRectifierGroupDefaultPowerLimit Integer32,
|
||
dcRectifierGroupInputLowOff Integer32,
|
||
dcRectifierGroupInputLowOn Integer32,
|
||
dcRectifierGroupStartupVoltage Integer32,
|
||
dcRectifierGroupStartupCurrentLimit Integer32,
|
||
dcRectifierGroupStartupPowerLimit Integer32,
|
||
dcRectifierGroupStartupTimeLimit Gauge32,
|
||
dcRectifierGroupPowerupDelay Gauge32,
|
||
dcRectifierGroupPowerupTime Gauge32,
|
||
dcRectifierGroupUmaxOff Integer32 }
|
||
|
||
dcRectifierGroupIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..1)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table index."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.1 --
|
||
::= { dcRectifierGroupEntry 1 }
|
||
|
||
dcRectifierGroupName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (1..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Rectifier group name to identify an individual device
|
||
parameter set."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.2 --
|
||
::= { dcRectifierGroupEntry 2 }
|
||
|
||
dcRectifierGroupRectifierType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown48V(1),
|
||
fR48V2000W(2),
|
||
dPR1200B48(3),
|
||
dPR1500B48(4),
|
||
dPR600B48(5),
|
||
dPR7200B48(6),
|
||
fR48to60V2000W(7),
|
||
unknown24V(8),
|
||
unknown60V(9),
|
||
dPR600B60(10),
|
||
dPR3500B48(11),
|
||
dPR3500B24(12),
|
||
dPR300B48(13),
|
||
dPR1600B48(14),
|
||
dPR2700B48(15),
|
||
dPR2400B48(16),
|
||
dPR4000B48(17),
|
||
dPR2900B48(18),
|
||
dPR4000B48to60(19),
|
||
dPR850B48(20),
|
||
dPR2000B48(21) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Rectifier type defined for this group."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.3 --
|
||
::= { dcRectifierGroupEntry 3 }
|
||
|
||
dcRectifierGroupDefaultVoltage OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This default voltage is used by rectifiers when there
|
||
is no connection to PSC 3."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.4 --
|
||
::= { dcRectifierGroupEntry 4 }
|
||
|
||
dcRectifierGroupDefaultCurrentLimit OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "100 mA"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This default current limit is used by rectifiers when there
|
||
is no connection to PSC 3."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.5 --
|
||
::= { dcRectifierGroupEntry 5 }
|
||
|
||
dcRectifierGroupDefaultPowerLimit OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "1 W"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This default power limit is used by rectifiers when there
|
||
is no connection to PSC 3."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.6 --
|
||
::= { dcRectifierGroupEntry 6 }
|
||
|
||
dcRectifierGroupInputLowOff OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Threshold for low AC input voltage. It can is used to
|
||
adjust the behaviour of the power system to the available
|
||
AC network limitation."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.7 --
|
||
::= { dcRectifierGroupEntry 7 }
|
||
|
||
dcRectifierGroupInputLowOn OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For details see dcRectifierGroupInputLowOff."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.8 --
|
||
::= { dcRectifierGroupEntry 8 }
|
||
|
||
dcRectifierGroupStartupVoltage OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Startup parameters are the values that rectifiers use
|
||
during the start-up phase. These parameters allow starting
|
||
the system smoothly after a mains failure even on a
|
||
discharged battery and even without PSC 3."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.9 --
|
||
::= { dcRectifierGroupEntry 9 }
|
||
|
||
dcRectifierGroupStartupCurrentLimit OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "100 mA"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For details see dcRectifierGroupStartupVoltage."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.10 --
|
||
::= { dcRectifierGroupEntry 10 }
|
||
|
||
dcRectifierGroupStartupPowerLimit OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "1 W"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For details see dcRectifierGroupStartupVoltage."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.11 --
|
||
::= { dcRectifierGroupEntry 11 }
|
||
|
||
dcRectifierGroupStartupTimeLimit OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "10 ms"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For details see dcRectifierGroupStartupVoltage."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.12 --
|
||
::= { dcRectifierGroupEntry 12 }
|
||
|
||
dcRectifierGroupPowerupDelay OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "10 ms"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This parameter is used after a mains failure to
|
||
delay the start-up of all rectifiers."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.13 --
|
||
::= { dcRectifierGroupEntry 13 }
|
||
|
||
dcRectifierGroupPowerupTime OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "10 ms"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This parameter used after a mains failure and allows
|
||
defining a time within all rectifiers needs to start-up
|
||
one after another."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.14 --
|
||
::= { dcRectifierGroupEntry 14 }
|
||
|
||
dcRectifierGroupUmaxOff OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "10 mV"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Overvoltage protection value."
|
||
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.15 --
|
||
::= { dcRectifierGroupEntry 15 }
|
||
|
||
-- ====================================================================
|
||
-- Rectifier Power Limitation table
|
||
-- ====================================================================
|
||
dcPowerLimitationTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF DcPowerLimitationEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table that shows parameters of the available power limitation
|
||
functions."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.2 --
|
||
::= { dcPowerLimitation 1 }
|
||
|
||
dcPowerLimitationEntry OBJECT-TYPE
|
||
SYNTAX DcPowerLimitationEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A particular power limitation entry."
|
||
INDEX { dcPowerLimitationIndex }
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.2.1 --
|
||
::= { dcPowerLimitationTable 1 }
|
||
|
||
DcPowerLimitationEntry ::= SEQUENCE {
|
||
dcPowerLimitationIndex Integer32,
|
||
dcPowerLimitationEventName DisplayString,
|
||
dcPowerLimitationStatus INTEGER,
|
||
dcPowerLimitationType INTEGER,
|
||
dcPowerLimitationLimit Integer32,
|
||
dcPowerLimitationNoBatteryDischarge INTEGER }
|
||
|
||
dcPowerLimitationIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..16)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table index."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.2.1.1 --
|
||
::= { dcPowerLimitationEntry 1 }
|
||
|
||
dcPowerLimitationEventName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (1..35))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Name of the power limitation event."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.2.1.2 --
|
||
::= { dcPowerLimitationEntry 2 }
|
||
|
||
dcPowerLimitationStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
disabled(1),
|
||
inactive(2),
|
||
powerLimit(3) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Status of power limitation."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.2.1.3 --
|
||
::= { dcPowerLimitationEntry 3 }
|
||
|
||
dcPowerLimitationType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
dynamic(1),
|
||
fixedLimit(2) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Power limitation type."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.2.1.4 --
|
||
::= { dcPowerLimitationEntry 4 }
|
||
|
||
dcPowerLimitationLimit OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "1 W"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Limit used for power limitation."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.2.1.5 --
|
||
::= { dcPowerLimitationEntry 5 }
|
||
|
||
dcPowerLimitationNoBatteryDischarge OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(1),
|
||
yes(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/disable no battery discharge during power limitation."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.4.6.2.1.6 --
|
||
::= { dcPowerLimitationEntry 6 }
|
||
|
||
-- ====================================================================
|
||
-- BatteryString table
|
||
-- ====================================================================
|
||
dcBatteryStringTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF DcBatteryStringEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table that shows parameters of the available battery strings."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.2 --
|
||
::= { dcBatteryParameter 2 }
|
||
|
||
dcBatteryStringEntry OBJECT-TYPE
|
||
SYNTAX DcBatteryStringEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A particular battery string entry."
|
||
INDEX { dcBatteryStringIndex }
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.2.1 --
|
||
::= { dcBatteryStringTable 1 }
|
||
|
||
DcBatteryStringEntry ::= SEQUENCE {
|
||
dcBatteryStringIndex Integer32,
|
||
dcBatteryStringName DisplayString,
|
||
dcBatteryStringMaxIBatt Integer32,
|
||
dcBatteryStringCapacity Gauge32 }
|
||
|
||
dcBatteryStringIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..16)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table index."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.2.1.1 --
|
||
::= { dcBatteryStringEntry 1 }
|
||
|
||
dcBatteryStringName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (1..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Name of the battery string."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.2.1.2 --
|
||
::= { dcBatteryStringEntry 2 }
|
||
|
||
dcBatteryStringMaxIBatt OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
UNITS "100 mA"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum battery charging current for this string. This
|
||
parameter can be set individually for each battery.
|
||
PSC 3 then regulates the system voltage such that the maximum
|
||
battery charging current of each battery is respected."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.2.1.3 --
|
||
::= { dcBatteryStringEntry 3 }
|
||
|
||
dcBatteryStringCapacity OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "100 mAh"
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Capacity of battery can be defined individually. It is used
|
||
to calculate the expected backup time of the system."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.5.3.2.1.4 --
|
||
::= { dcBatteryStringEntry 4 }
|
||
|
||
-- ====================================================================
|
||
-- Control Event table
|
||
-- ====================================================================
|
||
dcControlEventTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF DcControlEventEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table that shows ten output event assignments that can be
|
||
configured via WEB interface."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.6.1 --
|
||
::= { dcInputOutput 1 }
|
||
|
||
dcControlEventEntry OBJECT-TYPE
|
||
SYNTAX DcControlEventEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A particular generic output entry."
|
||
INDEX { dcControlEventIndex }
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.6.1.1 --
|
||
::= { dcControlEventTable 1 }
|
||
|
||
DcControlEventEntry ::= SEQUENCE {
|
||
dcControlEventIndex Integer32,
|
||
dcControlEventName DisplayString,
|
||
dcControlEventIdentifier Gauge32,
|
||
dcControlEventValue INTEGER }
|
||
|
||
dcControlEventIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..16)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table index."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.6.1.1.1 --
|
||
::= { dcControlEventEntry 1 }
|
||
|
||
dcControlEventName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..35))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Plain text name of the assigned control event. Empty if not
|
||
configure."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.6.1.1.2 --
|
||
::= { dcControlEventEntry 2 }
|
||
|
||
dcControlEventIdentifier OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Unique numeric identifier of the assigned control event. Zero
|
||
if not configured."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.6.1.1.3 --
|
||
::= { dcControlEventEntry 3 }
|
||
|
||
dcControlEventValue OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
false(1),
|
||
true(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current value of the assigned control event. Value is false if
|
||
not configured."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.6.1.1.4 --
|
||
::= { dcControlEventEntry 4 }
|
||
|
||
-- ====================================================================
|
||
-- Trap Destinations table
|
||
-- ====================================================================
|
||
dcTrapDestinationTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF DcTrapDestinationEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Trap table that shows all configured trap destinations."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.1 --
|
||
::= { dcMisc 1 }
|
||
|
||
dcTrapDestinationEntry OBJECT-TYPE
|
||
SYNTAX DcTrapDestinationEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A particular trap destination entry."
|
||
INDEX { dcTrapDestinationIndex }
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.1.1 --
|
||
::= { dcTrapDestinationTable 1 }
|
||
|
||
DcTrapDestinationEntry ::= SEQUENCE {
|
||
dcTrapDestinationIndex Integer32,
|
||
dcTrapDestinationIp IpAddress,
|
||
dcTrapDestinationPort Gauge32 }
|
||
|
||
dcTrapDestinationIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..10)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table index."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.1.1.1 --
|
||
::= { dcTrapDestinationEntry 1 }
|
||
|
||
dcTrapDestinationIp OBJECT-TYPE
|
||
SYNTAX IpAddress
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"IP address of the trap destination. Value is 0.0.0.0 if IP
|
||
address is not configured."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.1.1.2 --
|
||
::= { dcTrapDestinationEntry 2 }
|
||
|
||
dcTrapDestinationPort OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Port number of the trap destination. By default port 162
|
||
is used."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.7.1.1.3 --
|
||
::= { dcTrapDestinationEntry 3 }
|
||
|
||
-- ====================================================================
|
||
-- Default Log Config table
|
||
-- ====================================================================
|
||
dcDefaultLogEventTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF DcDefaultLogEventEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Event config table for default log."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.1 --
|
||
::= { dcConfig 1 }
|
||
|
||
dcDefaultLogEventEntry OBJECT-TYPE
|
||
SYNTAX DcDefaultLogEventEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A particular event entry."
|
||
INDEX { dcDefaultLogEventIndex }
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.1.1 --
|
||
::= { dcDefaultLogEventTable 1 }
|
||
|
||
DcDefaultLogEventEntry ::= SEQUENCE {
|
||
dcDefaultLogEventIndex Integer32,
|
||
dcDefaultLogEventName DisplayString,
|
||
dcDefaultLogEventLogged INTEGER }
|
||
|
||
dcDefaultLogEventIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1000)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table index."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.1.1.1 --
|
||
::= { dcDefaultLogEventEntry 1 }
|
||
|
||
dcDefaultLogEventName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (1..35))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Plain text name of the event that can be logged."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.1.1.2 --
|
||
::= { dcDefaultLogEventEntry 2 }
|
||
|
||
dcDefaultLogEventLogged OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(1),
|
||
yes(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If yes then this event is logged otherwise not."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.1.1.3 --
|
||
::= { dcDefaultLogEventEntry 3 }
|
||
|
||
-- ====================================================================
|
||
-- Event Processing Config table
|
||
-- ====================================================================
|
||
dcEventProcessingEventTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF DcEventProcessingEventEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Event config table for event ORs."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.2 --
|
||
::= { dcConfig 2 }
|
||
|
||
dcEventProcessingEventEntry OBJECT-TYPE
|
||
SYNTAX DcEventProcessingEventEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A particular event entry."
|
||
INDEX { dcEventProcessingEventIndex }
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.2.1 --
|
||
::= { dcEventProcessingEventTable 1 }
|
||
|
||
DcEventProcessingEventEntry ::= SEQUENCE {
|
||
dcEventProcessingEventIndex Integer32,
|
||
dcEventProcessingEventName DisplayString,
|
||
dcEventProcessingEventAssigned INTEGER,
|
||
dcEventProcessingEventType INTEGER }
|
||
|
||
dcEventProcessingEventIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (0..1000)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table index."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.2.1.1 --
|
||
::= { dcEventProcessingEventEntry 1 }
|
||
|
||
dcEventProcessingEventName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (1..35))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Plain text name of the input event."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.2.1.2 --
|
||
::= { dcEventProcessingEventEntry 2 }
|
||
|
||
dcEventProcessingEventAssigned OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
no(1),
|
||
yes(2) }
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"If yes then the input event is assigned to the selected
|
||
event. Please note, that it is only possible to change
|
||
assignment of event ORs."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.2.1.3 --
|
||
::= { dcEventProcessingEventEntry 3 }
|
||
|
||
dcEventProcessingEventType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(1),
|
||
eventOR(2) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Type of the input event."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.2.1.4 --
|
||
::= { dcEventProcessingEventEntry 4 }
|
||
|
||
-- ====================================================================
|
||
-- LVD Config table
|
||
-- ====================================================================
|
||
dcLvdTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF DcLvdEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table lists all available LVDs."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.4 --
|
||
::= { dcConfig 4 }
|
||
|
||
dcLvdEntry OBJECT-TYPE
|
||
SYNTAX DcLvdEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A particular LVD entry."
|
||
INDEX { dcLvdIndex }
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.4.1 --
|
||
::= { dcLvdTable 1 }
|
||
|
||
DcLvdEntry ::= SEQUENCE {
|
||
dcLvdIndex Integer32,
|
||
dcLvdName DisplayString,
|
||
dcLvdDisconnectDelay DisplayString }
|
||
|
||
dcLvdIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..96)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table index."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.4.1.1 --
|
||
::= { dcLvdEntry 1 }
|
||
|
||
dcLvdName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (1..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Name of the LVD."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.4.1.2 --
|
||
::= { dcLvdEntry 2 }
|
||
|
||
dcLvdDisconnectDelay OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (8))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Time delay from the activation of the source event, after
|
||
which the LVD event is switched. The value is in the format
|
||
'hh:mm:ss'."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.8.4.1.3 --
|
||
::= { dcLvdEntry 3 }
|
||
|
||
-- ====================================================================
|
||
-- Measurement table
|
||
-- ====================================================================
|
||
dcMeasurementTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF DcMeasurementEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table lists all available measurements."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.9.1 --
|
||
::= { dcMeasurement 1 }
|
||
|
||
dcMeasurementEntry OBJECT-TYPE
|
||
SYNTAX DcMeasurementEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A particular measurement entry."
|
||
INDEX { dcMeasurementIndex }
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.9.1.1 --
|
||
::= { dcMeasurementTable 1 }
|
||
|
||
DcMeasurementEntry ::= SEQUENCE {
|
||
dcMeasurementIndex Integer32,
|
||
dcMeasurementName DisplayString,
|
||
dcMeasurementValue Integer32,
|
||
dcMeasurementScaleFactor Integer32,
|
||
dcMeasurementUnit INTEGER }
|
||
|
||
dcMeasurementIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..500)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table index."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.9.1.1.1 --
|
||
::= { dcMeasurementEntry 1 }
|
||
|
||
dcMeasurementName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (1..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Name of the measurement."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.9.1.1.2 --
|
||
::= { dcMeasurementEntry 2 }
|
||
|
||
dcMeasurementValue OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Unscaled calibrated value of the measurement."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.9.1.1.3 --
|
||
::= { dcMeasurementEntry 3 }
|
||
|
||
dcMeasurementScaleFactor OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Scale factor as power of 10 to be multiplied with measurement value."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.9.1.1.4 --
|
||
::= { dcMeasurementEntry 4 }
|
||
|
||
dcMeasurementUnit OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(1),
|
||
none(2),
|
||
voltDC(3),
|
||
voltAC(4),
|
||
ampere(5),
|
||
ampereHour(6),
|
||
degreeCelsius(7),
|
||
temperatureCoefficient(8),
|
||
watt(9),
|
||
wattHour(10),
|
||
seconds(11),
|
||
percent(12),
|
||
hertz(13),
|
||
voltAmpere(14),
|
||
voltAmpereReactive(15),
|
||
voltAmpereReactiveHour(16) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Unit of the measurement."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.9.1.1.5 --
|
||
::= { dcMeasurementEntry 5 }
|
||
|
||
-- ====================================================================
|
||
-- Meter Panel Event table
|
||
-- ====================================================================
|
||
dcMeterPanelEventTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF DcMeterPanelEventEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table lists all available meter panel events."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.10.1 --
|
||
::= { dcMeterPanel 1 }
|
||
|
||
dcMeterPanelEventEntry OBJECT-TYPE
|
||
SYNTAX DcMeterPanelEventEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A particular meter panel event entry."
|
||
INDEX { dcMeterPanelEventIndex }
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.10.1.1 --
|
||
::= { dcMeterPanelEventTable 1 }
|
||
|
||
DcMeterPanelEventEntry ::= SEQUENCE {
|
||
dcMeterPanelEventIndex Integer32,
|
||
dcMeterPanelEventName DisplayString,
|
||
dcMeterPanelEventValue INTEGER,
|
||
dcMeterPanelEventHourMeterValue Gauge32 }
|
||
|
||
dcMeterPanelEventIndex OBJECT-TYPE
|
||
SYNTAX Integer32 (1..128)
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Table index."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.10.1.1.1 --
|
||
::= { dcMeterPanelEventEntry 1 }
|
||
|
||
dcMeterPanelEventName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (1..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Name of the event."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.10.1.1.2 --
|
||
::= { dcMeterPanelEventEntry 2 }
|
||
|
||
dcMeterPanelEventValue OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
false(1),
|
||
indeterminate(2),
|
||
true(3) }
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Value of the event."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.10.1.1.3 --
|
||
::= { dcMeterPanelEventEntry 3 }
|
||
|
||
dcMeterPanelEventHourMeterValue OBJECT-TYPE
|
||
SYNTAX Gauge32
|
||
UNITS "hours"
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Value of the hour meter event."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.2.10.1.1.4 --
|
||
::= { dcMeterPanelEventEntry 4 }
|
||
|
||
-- ====================================================================
|
||
-- Notifications
|
||
-- ====================================================================
|
||
systemNonUrgentAlarm NOTIFICATION-TYPE
|
||
OBJECTS {
|
||
dcSystemDateTime,
|
||
dcNumberNonUrgentAlarms,
|
||
dcNonUrgentAlarmIdentifier,
|
||
dcNonUrgentAlarmValue,
|
||
dcNonUrgentAlarmName }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The controller reports that one or more elements have changed
|
||
into none urgent alarm state."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.3.1.0.1 --
|
||
::= { controllerEventsV2 1 }
|
||
|
||
systemUrgentAlarm NOTIFICATION-TYPE
|
||
OBJECTS {
|
||
dcSystemDateTime,
|
||
dcNumberUrgentAlarms,
|
||
dcUrgentAlarmIdentifier,
|
||
dcUrgentAlarmValue,
|
||
dcUrgentAlarmName }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The controller reports that one or more elements have changed
|
||
into urgent alarm state."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.3.1.0.2 --
|
||
::= { controllerEventsV2 2 }
|
||
|
||
systemCriticalAlarm NOTIFICATION-TYPE
|
||
OBJECTS {
|
||
dcSystemDateTime,
|
||
dcNumberCriticalAlarms,
|
||
dcCriticalAlarmIdentifier,
|
||
dcCriticalAlarmValue,
|
||
dcCriticalAlarmName }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The controller reports that one or more elements have changed
|
||
into critical alarm state."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.3.1.0.3 --
|
||
::= { controllerEventsV2 3 }
|
||
|
||
-- ====================================================================
|
||
-- Conformance area, containing groups and compliance specifications
|
||
-- ====================================================================
|
||
systemInfoGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
dcSiteName,
|
||
dcSystemName,
|
||
dcSystemDateTime,
|
||
dcSoftwareVersion }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The collection of system info scalar objects."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.1 --
|
||
::= { controllerGroups 1 }
|
||
|
||
systemAlarmGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
dcNumberUrgentAlarms,
|
||
dcNumberNonUrgentAlarms,
|
||
dcMainsFailureAlarm,
|
||
dcUrgentAlarmIdentifier,
|
||
dcUrgentAlarmValue,
|
||
dcNonUrgentAlarmIdentifier,
|
||
dcNonUrgentAlarmValue,
|
||
dcUrgentAlarmName,
|
||
dcNonUrgentAlarmName,
|
||
dcNumberCriticalAlarms,
|
||
dcCriticalAlarmIdentifier,
|
||
dcCriticalAlarmValue,
|
||
dcCriticalAlarmName }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The collection of system alarm scalar objects."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.2 --
|
||
::= { controllerGroups 2 }
|
||
|
||
systemMonitorGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
dcSystemVoltage,
|
||
dcLoadCurrent,
|
||
dcBatteryCurrent,
|
||
dcBatteryTemperature,
|
||
dcChargeState,
|
||
dcCurrentLimit,
|
||
dcRectifierCurrent,
|
||
dcSystemPower }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The collection of system monitor scalar objects."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.3 --
|
||
::= { controllerGroups 3 }
|
||
|
||
rectifierGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
dcNumberRectifiers,
|
||
dcNumberRectifiersFailure,
|
||
dcNumberRectifiersOkay,
|
||
dcEfficiencyCyclingEnabled,
|
||
dcLimitSwitchingTimes,
|
||
dcForceSwitchingOncePerMonth,
|
||
dcMaximumLoadStep,
|
||
dcMinimumLoadStep }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The collection of rectifier scalar objects."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.4 --
|
||
::= { controllerGroups 4 }
|
||
|
||
eventHistoryTableGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
dcEventHistoryTimestamp,
|
||
dcEventHistoryMessage }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The collection of event history table objects."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.5 --
|
||
::= { controllerGroups 5 }
|
||
|
||
alarmTableGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
dcAlarmEventCategory,
|
||
dcAlarmEventName,
|
||
dcAlarmEventIdentifier,
|
||
dcAlarmEventValue }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The collection of alarm table objects."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.6 --
|
||
::= { controllerGroups 6 }
|
||
|
||
rectifierTableGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
dcRectifierIdentifier,
|
||
dcRectifierStatus }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The collection of rectifier table objects."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.7 --
|
||
::= { controllerGroups 7 }
|
||
|
||
notificationsGroup NOTIFICATION-GROUP
|
||
NOTIFICATIONS {
|
||
systemNonUrgentAlarm,
|
||
systemUrgentAlarm,
|
||
systemCriticalAlarm }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The group of all controller notifications."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.8 --
|
||
::= { controllerGroups 8 }
|
||
|
||
genericAlarmTableGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
dcGenericAlarmEventIdentifier,
|
||
dcGenericAlarmEventName,
|
||
dcGenericAlarmEventValue }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Assignment of events to alarm table entries."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.9 --
|
||
::= { controllerGroups 9 }
|
||
|
||
batteryGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
dcUsys20,
|
||
dcTempCompType,
|
||
dcSlope,
|
||
dcStartTemp,
|
||
dcStopTemp,
|
||
dcMaxVoltage,
|
||
dcLowStopVoltage,
|
||
dcLowStartTemp,
|
||
dcLowTempSlope,
|
||
dcHighStartTemp,
|
||
dcHighTempSlope,
|
||
dcHighStopVoltage,
|
||
dcRunawayTemp,
|
||
dcRunawayVoltage,
|
||
dcBatteryTestUsupport,
|
||
dcBatteryTestDuration,
|
||
dcBatteryTestInterval,
|
||
dcBatteryTestDischargeCurrent,
|
||
dcBatteryTestMinDuration,
|
||
dcBatteryTestVoltageWithinUfloat,
|
||
dcBatteryTestVoltageWithinUfloatPeriod,
|
||
dcBatteryTestTempFrom,
|
||
dcBatteryTestTempTo,
|
||
dcBatteryTestIntervalEnabled,
|
||
dcBatteryTestStartTimeFrom,
|
||
dcBatteryTestStartTimeTo,
|
||
dcBatteryTestDateTime,
|
||
dcBatteryTestResult,
|
||
dcBatteryTestEndVoltage,
|
||
dcBatteryTestControl,
|
||
dcBatteryTestStatus,
|
||
dcBatteryTestFailureEvent,
|
||
dcBatteryTestType,
|
||
dcTotalBatteryCapacity,
|
||
dcLossOfBackupTimeEnabled,
|
||
dcLossOfBackupTimeStatus,
|
||
dcExpectedBackupTime,
|
||
dcEqualizeControl,
|
||
dcEqualizeStatus,
|
||
dcEqualizeEnabled,
|
||
dcEqualizeVoltage,
|
||
dcEqualizeDuration,
|
||
dcEqualizeUseBattRoomFanEnabled,
|
||
dcEqualizeLeadTime,
|
||
dcEqualizeTimeLag,
|
||
dcEqualizeInterval,
|
||
dcEqualizeStartTimeIntervalFrom,
|
||
dcEqualizeStartTimeIntervalTo,
|
||
dcEqualizeInhibitAfterBoost,
|
||
dcBoostChargeControl,
|
||
dcBoostChargeStatus,
|
||
dcBoostChargeType,
|
||
dcBoostChargeVoltage,
|
||
dcBoostChargeMaxDuration,
|
||
dcBoostChargeUseBattRoomFanEnabled,
|
||
dcBoostChargeTimeLag,
|
||
dcBoostChargeIstart,
|
||
dcBoostChargeIstop,
|
||
dcBoostChargeInhibitTime,
|
||
dcUaMax,
|
||
dcUaMin,
|
||
dcUsMax,
|
||
dcUsMin,
|
||
dcBoD,
|
||
dcHysteresis,
|
||
dcSuppressUaLowEnabled,
|
||
dcSuppressUsLowEnabled,
|
||
dcEnableUsTempComp,
|
||
dcEvtCtrlChargeStatus,
|
||
dcEvtCtrlChargeType,
|
||
dcEvtCtrlChargeVoltage,
|
||
dcEvtCtrlChargeTempCompEnabled,
|
||
dcEvtCtrlChargeMaxIBatt,
|
||
dcHighTemp,
|
||
dcHighTempHyst }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The collection of battery scalar objects."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.10 --
|
||
::= { controllerGroups 10 }
|
||
|
||
controlEventTableGroup
|
||
OBJECT-GROUP
|
||
OBJECTS {
|
||
dcControlEventName,
|
||
dcControlEventIdentifier,
|
||
dcControlEventValue }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Assignment of control events to table entries."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.11 --
|
||
::= { controllerGroups 11 }
|
||
|
||
trapDestinationTableGroup
|
||
OBJECT-GROUP
|
||
OBJECTS {
|
||
dcTrapDestinationIp,
|
||
dcTrapDestinationPort }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Trap destionation table."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.12 --
|
||
::= { controllerGroups 12 }
|
||
|
||
miscGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
dcFileProcessingStatus,
|
||
dcResendActiveAlarmTraps }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The collection of miscellaneous objects."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.13 --
|
||
::= { controllerGroups 13 }
|
||
|
||
rectifierGroupTableGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
dcRectifierGroupName,
|
||
dcRectifierGroupRectifierType,
|
||
dcRectifierGroupDefaultVoltage,
|
||
dcRectifierGroupDefaultCurrentLimit,
|
||
dcRectifierGroupDefaultPowerLimit,
|
||
dcRectifierGroupInputLowOff,
|
||
dcRectifierGroupInputLowOn,
|
||
dcRectifierGroupStartupVoltage,
|
||
dcRectifierGroupStartupCurrentLimit,
|
||
dcRectifierGroupStartupPowerLimit,
|
||
dcRectifierGroupStartupTimeLimit,
|
||
dcRectifierGroupPowerupDelay,
|
||
dcRectifierGroupPowerupTime,
|
||
dcRectifierGroupUmaxOff }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The collection of rectifier group table objects."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.14 --
|
||
::= { controllerGroups 14 }
|
||
|
||
batteryStringTableGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
dcBatteryStringName,
|
||
dcBatteryStringMaxIBatt,
|
||
dcBatteryStringCapacity }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The collection of battery string table objects."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.15 --
|
||
::= { controllerGroups 15 }
|
||
|
||
defaultLogEventTableGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
dcDefaultLogEventName,
|
||
dcDefaultLogEventLogged }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The collection of default log event table objects."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.16 --
|
||
::= { controllerGroups 16 }
|
||
|
||
eventProcessingEventTableGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
dcEventProcessingEventName,
|
||
dcEventProcessingEventAssigned,
|
||
dcEventProcessingEventType,
|
||
dcEventProcessingEventSelected }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The collection of event processing event table objects."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.17 --
|
||
::= { controllerGroups 17 }
|
||
|
||
lvdTableGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
dcLvdName,
|
||
dcLvdDisconnectDelay }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The collection of LVD table objects."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.18 --
|
||
::= { controllerGroups 18 }
|
||
|
||
powerLimitationTableGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
dcPowerLimitationEventName,
|
||
dcPowerLimitationStatus,
|
||
dcPowerLimitationType,
|
||
dcPowerLimitationLimit,
|
||
dcPowerLimitationNoBatteryDischarge }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The collection of power limitation table objects."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.19 --
|
||
::= { controllerGroups 19 }
|
||
|
||
measurementTableGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
dcMeasurementName,
|
||
dcMeasurementValue,
|
||
dcMeasurementScaleFactor,
|
||
dcMeasurementUnit }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The collection of measurement table objects."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.20 --
|
||
::= { controllerGroups 20 }
|
||
|
||
meterPanelEventTableGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
dcMeterPanelEventName,
|
||
dcMeterPanelEventValue,
|
||
dcMeterPanelEventHourMeterValue }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The collection of meter panel event table objects."
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.1.21 --
|
||
::= { controllerGroups 21 }
|
||
|
||
controllerBasicCompl MODULE-COMPLIANCE
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The basic implementation requirements for the controller MIB."
|
||
MODULE
|
||
MANDATORY-GROUPS {
|
||
systemInfoGroup,
|
||
systemAlarmGroup,
|
||
systemMonitorGroup,
|
||
alarmTableGroup,
|
||
notificationsGroup }
|
||
-- 1.3.6.1.4.1.20246.2.3.1.1.1.1.2.1 --
|
||
::= { controllerCompl 1 }
|
||
|
||
END
|