IDKT-F2-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32,
|
|
Counter32 FROM SNMPv2-SMI
|
|
OBJECT-GROUP FROM SNMPv2-CONF
|
|
dkt FROM DKT-MIB
|
|
MacAddress FROM SNMPv2-TC;
|
|
|
|
f2MIB MODULE-IDENTITY
|
|
LAST-UPDATED "201504210000Z"
|
|
ORGANIZATION "DKT A/S"
|
|
CONTACT-INFO
|
|
"postal: DKT A/S
|
|
Fanoevej 6
|
|
DK-4060 Kirke Saaby
|
|
Denmark
|
|
|
|
email: info@dktcomega.com"
|
|
DESCRIPTION "DKT 797xx series MIB."
|
|
::= { dkt 15 }
|
|
|
|
f2SwitchEngine OBJECT IDENTIFIER ::= { f2MIB 1 }
|
|
|
|
f2IGMPSnooping OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Starts/stops IGMP snooping, input parameter 0 = stops IGMP snooping, 1 = starts IGMP snooping. Per Default IGMP snooping is disabled."
|
|
::= { f2SwitchEngine 1 }
|
|
|
|
f2MTU OBJECT-TYPE
|
|
SYNTAX INTEGER (0..8960)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set and get MTU. The following values are valid: 3072, 4096, 6144, 8960 (3k, 4k, 6k and 8960 bytes)"
|
|
::= { f2SwitchEngine 2 }
|
|
|
|
f2FWDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF F2FWDMacAddressEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Get learned MAC addresses from LAN side of switch engine"
|
|
::= { f2SwitchEngine 3 }
|
|
|
|
f2FWDMacAddressEntry OBJECT-TYPE
|
|
SYNTAX F2FWDMacAddressEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Learned MAC address from LAN side of switch engine"
|
|
::= { f2FWDTable 1 }
|
|
|
|
F2FWDMacAddressEntry ::= SEQUENCE {
|
|
F2FWDMacAddress OCTET STRING
|
|
}
|
|
|
|
F2FWDMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MAC address from LAN"
|
|
::= { f2FWDMacAddressEntry 1 }
|
|
|
|
f2Ports OBJECT IDENTIFIER ::= { f2MIB 2 }
|
|
|
|
f2CPUPort OBJECT IDENTIFIER ::= { f2Ports 1 }
|
|
|
|
f2CPUPortAutoNegotiation OBJECT-TYPE
|
|
SYNTAX INTEGER (0..10)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays auto negotiation state for the port."
|
|
::= { f2CPUPort 1 }
|
|
|
|
f2CPUPortSpeedMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..10))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the speed and duplex mode on the port."
|
|
::= { f2CPUPort 2 }
|
|
|
|
|
|
f2CPUPortLinkStatus OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the Link status for the port"
|
|
::= { f2CPUPort 3 }
|
|
|
|
|
|
f2CPUPortFlowControl OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control"
|
|
::= { f2CPUPort 4 }
|
|
|
|
|
|
f2CPUPortEnable OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status for CPU port. Always 1 for enabled."
|
|
::= { f2CPUPort 5 }
|
|
|
|
|
|
f2WANPort OBJECT IDENTIFIER ::= { f2Ports 2 }
|
|
|
|
f2WANPortAutoNegotiation OBJECT-TYPE
|
|
SYNTAX INTEGER (0..10)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays auto negotiation state for the port."
|
|
::= { f2WANPort 1 }
|
|
|
|
f2WANPortSpeedMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..10))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)"
|
|
::= { f2WANPort 2 }
|
|
|
|
|
|
f2WANPortLinkStatus OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the Link status for the port"
|
|
::= { f2WANPort 3 }
|
|
|
|
|
|
f2WANPortFlowControl OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control"
|
|
::= { f2WANPort 4 }
|
|
|
|
|
|
f2WANPortEnable OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status for WAN port. Always 1 for enabled."
|
|
::= { f2WANPort 5 }
|
|
|
|
|
|
|
|
f2LAN1Port OBJECT IDENTIFIER ::= { f2Ports 3 }
|
|
|
|
f2LAN1PortAutoNegotiation OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays auto negotiation state for the port."
|
|
::= { f2LAN1Port 1 }
|
|
|
|
f2LAN1PortSpeedMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..10))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)"
|
|
::= { f2LAN1Port 2 }
|
|
|
|
|
|
f2LAN1PortLinkStatus OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the Link status for the port"
|
|
::= { f2LAN1Port 3 }
|
|
|
|
|
|
f2LAN1PortFlowControl OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control"
|
|
::= { f2LAN1Port 4 }
|
|
|
|
|
|
f2LAN1PortEnable OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables/Disables LAN1 port. Set to 1 for Enabled set to 0 for Disabled."
|
|
::= { f2LAN1Port 5 }
|
|
|
|
|
|
|
|
f2LAN2Port OBJECT IDENTIFIER ::= { f2Ports 4 }
|
|
|
|
f2LAN2PortAutoNegotiation OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays auto negotiation state for the port."
|
|
::= { f2LAN2Port 1 }
|
|
|
|
f2LAN2PortSpeedMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..10))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)"
|
|
::= { f2LAN2Port 2 }
|
|
|
|
|
|
f2LAN2PortLinkStatus OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the Link status for the port"
|
|
::= { f2LAN2Port 3 }
|
|
|
|
|
|
f2LAN2PortFlowControl OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control"
|
|
::= { f2LAN2Port 4 }
|
|
|
|
|
|
f2LAN2PortEnable OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables/Disables LAN2 port. Set to 1 for Enabled set to 0 for Disabled."
|
|
::= { f2LAN2Port 5 }
|
|
|
|
|
|
|
|
f2LAN3Port OBJECT IDENTIFIER ::= { f2Ports 5 }
|
|
|
|
f2LAN3PortAutoNegotiation OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays auto negotiation state for the port."
|
|
::= { f2LAN3Port 1 }
|
|
|
|
f2LAN3PortSpeedMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..10))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)"
|
|
::= { f2LAN3Port 2 }
|
|
|
|
|
|
f2LAN3PortLinkStatus OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the Link status for the port"
|
|
::= { f2LAN3Port 3 }
|
|
|
|
|
|
f2LAN3PortFlowControl OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control"
|
|
::= { f2LAN3Port 4 }
|
|
|
|
|
|
f2LAN3PortEnable OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables/Disables LAN3 port. Set to 1 for Enabled set to 0 for Disabled."
|
|
::= { f2LAN3Port 5 }
|
|
|
|
|
|
f2LAN4Port OBJECT IDENTIFIER ::= { f2Ports 6 }
|
|
|
|
f2LAN4PortAutoNegotiation OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays auto negotiation state for the port."
|
|
::= { f2LAN4Port 1 }
|
|
|
|
f2LAN4PortSpeedMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..10))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the speed and duplex mode on the port. Valid values are (1000FD|1000HD|100FD|100HD)"
|
|
::= { f2LAN4Port 2 }
|
|
|
|
|
|
f2LAN4PortLinkStatus OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the Link status for the port"
|
|
::= { f2LAN4Port 3 }
|
|
|
|
|
|
f2LAN4PortFlowControl OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays flow control status for the port. Values: 0: No flow control, 1: Rx flow control, 2: Tx flow control, 3: Rx and Tx flow control"
|
|
::= { f2LAN4Port 4 }
|
|
|
|
|
|
f2LAN4PortEnable OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables/Disables LAN4 port. Set to 1 for Enabled set to 0 for Disabled."
|
|
::= { f2LAN4Port 5 }
|
|
|
|
|
|
|
|
|
|
f2ModuleGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
f2SwitchEngine,
|
|
f2IGMPSnooping,
|
|
f2MTU,
|
|
f2Ports,
|
|
f2CPUPort,
|
|
f2CPUPortAutoNegotiation, f2CPUPortSpeedMode, f2CPUPortLinkStatus, f2CPUPortFlowControl, f2CPUPortEnable,
|
|
f2WANPort,
|
|
f2WANPortAutoNegotiation, f2WANPortSpeedMode, f2WANPortLinkStatus, f2WANPortFlowControl, f2WANPortEnable,
|
|
f2LAN1Port,
|
|
f2LAN1PortAutoNegotiation, f2LAN1PortSpeedMode, f2LAN1PortLinkStatus, f2LAN1PortFlowControl, f2LAN1PortEnable,
|
|
f2LAN2Port,
|
|
f2LAN2PortAutoNegotiation, f2LAN2PortSpeedMode, f2LAN2PortLinkStatus, f2LAN2PortFlowControl, f2LAN2PortEnable,
|
|
f2LAN3Port,
|
|
f2LAN3PortAutoNegotiation, f2LAN3PortSpeedMode, f2LAN3PortLinkStatus, f2LAN3PortFlowControl, f2LAN3PortEnable,
|
|
f2LAN4Port,
|
|
f2LAN4PortAutoNegotiation, f2LAN4PortSpeedMode, f2LAN4PortLinkStatus, f2LAN4PortFlowControl, f2LAN4PortEnable
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The objects are related to the DKT 797xx series module, MIB rev 09."
|
|
::= { f2MIB 3 }
|
|
|
|
|
|
END
|