mibs/MIBS/dlink/AGENT-GENERAL-MIB
2023-12-05 12:25:34 +01:00

3550 lines
127 KiB
Plaintext

AGENT-GENERAL-MIB DEFINITIONS ::= BEGIN
IMPORTS
IpAddress, MODULE-IDENTITY,
OBJECT-TYPE,Integer32 FROM SNMPv2-SMI
TruthValue,RowStatus, MacAddress FROM SNMPv2-TC
DisplayString FROM RFC1213-MIB
InetAddressType, InetAddress FROM INET-ADDRESS-MIB
AgentNotifyLevel,dlink-common-mgmt FROM DLINK-ID-REC-MIB
VlanId FROM Q-BRIDGE-MIB;
agentGeneralMgmt MODULE-IDENTITY
LAST-UPDATED "201206260000Z"
ORGANIZATION "D-Link Corp."
CONTACT-INFO
"http://support.dlink.com"
DESCRIPTION
"The structure of general management information for enterprise."
::= { dlink-common-mgmt 1 }
-- -----------------------------------------------------------------------------
-- Textual Conventions
-- -----------------------------------------------------------------------------
-- This definition may be excluded if IPv6 is not supported
Ipv6Address ::= TEXTUAL-CONVENTION
DISPLAY-HINT "2x:"
STATUS current
DESCRIPTION
"This data type is used to model IPv6 addresses.
This is a binary string of 16 octets in network
byte-order."
SYNTAX OCTET STRING (SIZE (16))
UnitList ::= OCTET STRING(SIZE (0..3))
-- -----------------------------------------------------------------------------
-- agentBasicInfo
-- -----------------------------------------------------------------------------
agentBasicInfo OBJECT IDENTIFIER ::= { agentGeneralMgmt 1 }
agentMgmtProtocolCapability OBJECT-TYPE
SYNTAX INTEGER {
other(1),
snmp-ip(2),
snmp-ipx(3),
snmp-ip-ipx(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The network management protocol(s) supported by this agent."
::= { agentBasicInfo 1 }
-- -----------------------------------------------------------------------------
-- agentMibcapabilityTable
-- -----------------------------------------------------------------------------
agentMibCapabilityTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentMibCapabilityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of MIB capability entries supported by this agent."
::= { agentBasicInfo 2 }
agentMibCapabilityEntry OBJECT-TYPE
SYNTAX AgentMibCapabilityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A MIB capability entry containing objects that describe a particular MIB
supported by this agent."
INDEX { agentMibCapabilityIndex }
::= { agentMibCapabilityTable 1 }
AgentMibCapabilityEntry ::=
SEQUENCE {
agentMibCapabilityIndex
Integer32,
agentMibCapabilityDescr
DisplayString,
agentMibCapabilityVersion
Integer32,
agentMibCapabilityType
INTEGER
}
agentMibCapabilityIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A list of Agent MIB Capability Description entries."
::= { agentMibCapabilityEntry 1 }
agentMibCapabilityDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..35))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the MIB supported by the agent."
::= { agentMibCapabilityEntry 2 }
agentMibCapabilityVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of the MIB specified in this entry."
::= { agentMibCapabilityEntry 3 }
agentMibCapabilityType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
standard(2),
proprietary(3),
experiment(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of MIB specified in this entry."
::= { agentMibCapabilityEntry 4 }
agentStatusConsoleInUse OBJECT-TYPE
SYNTAX INTEGER {
other(1),
in-use(2),
not-in-use(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This indicates whether the console is currently in use."
::= { agentBasicInfo 3 }
agentStatusSaveCfg OBJECT-TYPE
SYNTAX INTEGER {
other(1),
proceeding(2),
completed(3),
failed(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This indicates the status of the device configuration.
other (1) - This entry is currently in use but the conditions under
which it will remain so are determined by each of the following values.
proceeding (2) - The device configuration is currently being saved into NV-RAM.
completed (3) - All of the device configuration parameters have been
saved into NV-RAM.
failed (4) - The process to save the device configuration has failed."
::= { agentBasicInfo 4 }
agentStatusFileTransfer OBJECT-TYPE
SYNTAX INTEGER {
other(1) ,
in-process(2),
invalid-file(3),
violation(4),
file-not-found(5),
disk-full(6),
complete(7),
time-out(8),
not-format(9),
memory-full(10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the firmware download control. If the value is stated as 'other',
the firmware has not been updated since the device was started."
::= { agentBasicInfo 5 }
-- -----------------------------------------------------------------------------
-- agentCPUutilizationTable
-- -----------------------------------------------------------------------------
agentCPUutilization OBJECT IDENTIFIER ::= { agentBasicInfo 6 }
agentCPUutilizationIn5sec OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time scale is set at 5 second intervals.
The value will be between 0% (idle) and 100% (very busy)."
::= { agentCPUutilization 1 }
agentCPUutilizationIn1min OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time scale is set at 1 minute intervals.
The value will be between 0% (idle) and 100% (very busy)."
::= { agentCPUutilization 2 }
agentCPUutilizationIn5min OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time scale is set at 5 minute intervals.
The value will be between 0% (idle) and 100% (very busy)."
::= { agentCPUutilization 3 }
agentDualImageStatus OBJECT-TYPE
SYNTAX INTEGER {
not-supported(0),
supported(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The dual image status."
::= { agentBasicInfo 7 }
-- -----------------------------------------------------------------------------
-- agentPORTutilizationTable
-- -----------------------------------------------------------------------------
agentPORTutilizationTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentPORTutilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table specifies the current utilization of a specified port."
::= { agentBasicInfo 8 }
agentPORTutilizationEntry OBJECT-TYPE
SYNTAX AgentPORTutilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information regarding the port utilization function."
INDEX { agentPORTutilizationProtIndex }
::= { agentPORTutilizationTable 1 }
AgentPORTutilizationEntry ::=
SEQUENCE {
agentPORTutilizationProtIndex
INTEGER,
agentPORTutilizationTX
INTEGER,
agentPORTutilizationRX
INTEGER,
agentPORTutilizationUtil
INTEGER,
agentPORTutilizationRXUtil
INTEGER,
agentPORTutilizationTXUtil
INTEGER
}
agentPORTutilizationProtIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the module's port number."
::= { agentPORTutilizationEntry 1 }
agentPORTutilizationTX OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current rate of transmitted frames on the specified port."
::= { agentPORTutilizationEntry 2 }
agentPORTutilizationRX OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current rate of received frames on the specified port."
::= { agentPORTutilizationEntry 3 }
agentPORTutilizationUtil OBJECT-TYPE
SYNTAX INTEGER (0..100)
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current percentages regarding port statistics."
::= { agentPORTutilizationEntry 4 }
agentPORTutilizationRXUtil OBJECT-TYPE
SYNTAX INTEGER (0..100)
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current percentages regarding port receive packets statistics."
::= { agentPORTutilizationEntry 5 }
agentPORTutilizationTXUtil OBJECT-TYPE
SYNTAX INTEGER (0..100)
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current percentages regarding port transmit packets statistics."
::= { agentPORTutilizationEntry 6 }
-- -----------------------------------------------------------------------------
agentDRAMutilizationTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentDRAMutilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about DRAM memory."
::={agentBasicInfo 9}
agentDRAMutilizationEntry OBJECT-TYPE
SYNTAX AgentDRAMutilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information about DRAM memory."
INDEX {agentDRAMutilizationUnitID}
::={agentDRAMutilizationTable 1}
AgentDRAMutilizationEntry ::=
SEQUENCE {
agentDRAMutilizationUnitID
INTEGER,
agentDRAMutilizationTotalDRAM
INTEGER,
agentDRAMutilizationUsedDRAM
INTEGER,
agentDRAMutilization
INTEGER
}
agentDRAMutilizationUnitID OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the unit ID.
If the ID equals zero, it means the current device."
::={ agentDRAMutilizationEntry 1 }
agentDRAMutilizationTotalDRAM OBJECT-TYPE
SYNTAX INTEGER
UNITS "KB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The size of total DRAM memory."
::={agentDRAMutilizationEntry 2}
agentDRAMutilizationUsedDRAM OBJECT-TYPE
SYNTAX INTEGER
UNITS "KB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The size of used DRAM memory."
::={agentDRAMutilizationEntry 3}
agentDRAMutilization OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The percentage of used DRAM memory of the total DRAM memory available.
The value will be between 0% (idle) and 100% (very busy)."
::={agentDRAMutilizationEntry 4}
-- -----------------------------------------------------------------------------
agentFLASHutilizationTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentFLASHutilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about the flash memory."
::={agentBasicInfo 10}
agentFLASHutilizationEntry OBJECT-TYPE
SYNTAX AgentFLASHutilizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about the flash memory."
INDEX {agentFLASHutilizationUnitID}
::={agentFLASHutilizationTable 1}
AgentFLASHutilizationEntry ::=
SEQUENCE {
agentFLASHutilizationUnitID
INTEGER,
agentFLASHutilizationTotalFLASH
INTEGER,
agentFLASHutilizationUsedFLASH
INTEGER,
agentFLASHutilization
INTEGER
}
agentFLASHutilizationUnitID OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the unit ID.
If the ID equals zero, it means the current device."
::={ agentFLASHutilizationEntry 1 }
agentFLASHutilizationTotalFLASH OBJECT-TYPE
SYNTAX INTEGER
UNITS "KB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total size of flash memory."
::={agentFLASHutilizationEntry 2}
agentFLASHutilizationUsedFLASH OBJECT-TYPE
SYNTAX INTEGER
UNITS "KB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The size of the used flash memory."
::={agentFLASHutilizationEntry 3}
agentFLASHutilization OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The percentage of used flash memory in total flash memory.
The value will be between 0% (idle) and 100% (very busy)."
::={agentFLASHutilizationEntry 4}
-- -----------------------------------------------------------------------------
agentStatusReset OBJECT-TYPE
SYNTAX INTEGER {
proceeding(1),
completed(2),
failed(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This indicates the status of 'agentReset'."
::= { agentBasicInfo 11 }
agentSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A text string containing the serial number of this device."
::= { agentBasicInfo 12 }
-- -----------------------------------------------------------------------------
agentFirmwareType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A text string containing the firmware type."
::= { agentBasicInfo 13 }
-- -----------------------------------------------------------------------------
-- agentBasicConfig
-- -----------------------------------------------------------------------------
agentBasicConfig OBJECT IDENTIFIER ::= { agentGeneralMgmt 2 }
agentBscSwFileTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentBscSwFileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of MIB Basic Config entry support files updated by this agent."
::= { agentBasicConfig 1 }
agentBscSwFileEntry OBJECT-TYPE
SYNTAX AgentBscSwFileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A basic configuration entry containing the objects that describe a particular MIB
supported by this agent."
INDEX { agentBscSwFileIndex }
::= { agentBscSwFileTable 1 }
AgentBscSwFileEntry ::=
SEQUENCE {
agentBscSwFileIndex
Integer32,
agentBscSwFileDscr
DisplayString,
agentBscSwFileAddr
IpAddress,
agentBscSwFileTransferType
INTEGER,
agentBscSwFile
DisplayString,
agentBscSwFileLocateId
INTEGER,
agentBscSwFileLoadType
INTEGER,
agentBscSwFileCtrl
INTEGER,
agentBscSwFileBIncrement
TruthValue,
agentBscSwFileCtrlID
INTEGER,
agentBscSwFileCtrlUnitID
UnitList,
agentBscSwFileIPv6Addr
Ipv6Address,
agentBscSwFileBootUpImage
TruthValue,
agentBscSwFileForceAgree
TruthValue,
agentBscSwFileInterfaceName
DisplayString,
agentBscSwFileServerDomainName
DisplayString
}
agentBscSwFileIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The table index for the file entry"
::= { agentBscSwFileEntry 1 }
agentBscSwFileDscr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The description of the software file purpose in this entry.
Note: For systems that do not support a change to this object, setting a value for
this object will cause the system to return bad-value error messages."
::= { agentBscSwFileEntry 2 }
agentBscSwFileAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address where the file that needs to be downloaded is located, or the IP address
where the file will be uploaded to."
::= { agentBscSwFileEntry 3 }
agentBscSwFileTransferType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
network-load(2),
out-of-band-load(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The channel through which the file will be downloaded or uploaded.
Note: For systems that do not support all channels, setting a value to the unsupported
channel will cause the system to return bad-value error messages."
::= { agentBscSwFileEntry 4 }
agentBscSwFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the file to be downloaded from, or uploaded to, the TFTP server."
::= { agentBscSwFileEntry 5 }
agentBscSwFileLocateId OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object describes the type of file.
runtime-code (1),
log-file (2),
cfg-file (3)
Note: For systems that do not support changes to this object, setting a value for
this object will cause the system to return bad-value error messages."
::= { agentBscSwFileEntry 6 }
agentBscSwFileLoadType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
upload(2),
download(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object provides the user with a choice of uploading or downloading the selected file.
Note: For systems that do not support a change to this object, setting a value for this object
will cause the system to return bad-value error messages."
::= { agentBscSwFileEntry 7 }
agentBscSwFileCtrl OBJECT-TYPE
SYNTAX INTEGER {
other(1),
inactive(2),
start(3),
delete(4),
config-as-bootup(5),
apply(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object gives the user the option of downloading runtime software. This setting will take effect
when the system restarts. See Note (1) below
Note:
For systems that do not support changes to this object, setting a value to this object
will cause the system to return bad-value error messages.
start - Activate firmware.
delete (4) - Delete the firmware by indicated firmware ID.
config-as-bootup (5) - Configured as bootup firmware by the indicated
firmware(ID).
apply (6) - Apply the configuration to be the active configuration by the indicated config ID."
::= { agentBscSwFileEntry 8 }
agentBscSwFileBIncrement OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the previous configuration will remain
valid or not after downloading the configuration file.
True: Keep valid
False: Erase. "
::= { agentBscSwFileEntry 9 }
agentBscSwFileCtrlID OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The section ID of the firmware image or configuration file.
A value of 0 indicates the boot-up firmware image or configuration file."
::= { agentBscSwFileEntry 10 }
agentBscSwFileCtrlUnitID OBJECT-TYPE
SYNTAX UnitList
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies which unit of the switch stack the firmware image will be downloaded from.
One or more units can be set in this list. Each bit from the left to the right represents the
switch from unit ID 1 to unit ID 12.
A null entry in this field denotes all switches in the switch stack."
::= { agentBscSwFileEntry 11 }
agentBscSwFileIPv6Addr OBJECT-TYPE
SYNTAX Ipv6Address
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv6 address where the file will be downloaded from or uploaded to."
::= { agentBscSwFileEntry 12 }
agentBscSwFileBootUpImage OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The result of the download will depend on whether the boot_up option is specified.
Case 1: In the case where the master unit provides the file system and the slave unit does
not provide the file system, when boot_up is specified, the file will be downloaded
to the boot_up image on the slave. If boot_up is not specified, then the file will
not be downloaded to this slave unit.
Case 2: In the case where the master unit does not provide the file system and the slave unit
provides the file system, when boot_up is specified, the file will be downloaded to
the boot_up image on the slave unit. If boot_up is not specified, the file will
not be downloaded to this slave unit.
Case 3: In the case where the master unit and the slave unit both support or do not support
the file system, the file will be downloaded to the specified file on the slave unit.
If boot_up is specified, the downloaded file will be assigned as the boot_up image.
True: boot_up option is specified.
False: boot_up option is not specified. "
::= { agentBscSwFileEntry 13 }
agentBscSwFileForceAgree OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the force_agree option is specified, the reboot command will be executed
immediately, without any further confirmation from the user.
True: force_agree option is specified.
False: force_agree option is not specified. "
::= { agentBscSwFileEntry 14 }
agentBscSwFileInterfaceName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..12))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This node is used to specify the interface name when the agentBscSwFileIPv6Addr
is the link local address."
::= { agentBscSwFileEntry 15 }
agentBscSwFileServerDomainName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the domain name of the TFTP server."
::= { agentBscSwFileEntry 16 }
agentFileTransfer OBJECT-TYPE
SYNTAX INTEGER {
other(1),
start(2),
start-and-reset(3),
noaction(4)
}
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"This object will execute the download or upload action. If start (2) is chosen, it will
begin to download/upload and no reset will follow. If start-and-reset (3) is chosen,
then the reset will be activated after completing the download or upload.
No action if noaction (4) is chosen.
Note:
Because these functions will be limited by the support for the system in question,
some of the selected items will be invalid. When the user selects an invalid entry,
the system will respond with a bad-value status."
::= { agentBasicConfig 2 }
agentSystemReset OBJECT-TYPE
SYNTAX INTEGER {
other(1),
cold-start(2),
warm-start(3),
no-reset(4)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates the agent system reset state. Setting this
object to no-reset (4) has no effect. Setting this object to
cold-start (2) or warm-start (3) will reset the agent. The agent
always returns to no-reset (4) when this object is read.
This object is replaced by 'agentReset'."
::= { agentBasicConfig 3 }
agentRs232PortConfig OBJECT-TYPE
SYNTAX INTEGER {
other(1),
console(2),
out-of-band(3),
notAvail(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the RS-232C mode once the device has restarted."
::= { agentBasicConfig 4 }
agentOutOfBandBaudRateConfig OBJECT-TYPE
SYNTAX INTEGER {
other(1),
baudRate-2400 (2),
baudRate-9600 (3),
baudRate-19200(4),
baudRate-38400(5),
baudRate-115200(6)
}
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"This object allows the user to specify an out-of-band baud rate, which
will take effect upon system restart.
Note:
Because these functions will be limited by the support for the system
in question, some of the selected items will be invalid. When the user
selects an invalid entry, the system will respond with a bad-value error message.
"
::= { agentBasicConfig 5 }
agentSaveCfg OBJECT-TYPE
SYNTAX INTEGER {
other(1),
cfg-id1(2),
cfg-id2(3),
log(4),
all(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the type of save command to be executed, when saving to NV-RAM.
other (1) - None of the following.
cfg-id1 (2) - Save configuration ID1.
cfg-id2 (3)- Save configuration ID2.
log (4) - Save log.
all (5) - Save both (active configuration and log)."
::= { agentBasicConfig 6 }
-- -----------------------------------------------------------------------------
-- swMultiImageInfoTable
-- -----------------------------------------------------------------------------
swMultiImageInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwMultiImageInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { agentBasicConfig 7 }
swMultiImageInfoEntry OBJECT-TYPE
SYNTAX SwMultiImageInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information about multiple image management."
INDEX { swMultiImageInfoID }
::= { swMultiImageInfoTable 1 }
SwMultiImageInfoEntry ::=
SEQUENCE {
swMultiImageInfoID
INTEGER,
swMultiImageVersion
DisplayString,
swMultiImageSize
Integer32,
swMultiImageUpdateTime
DisplayString,
swMultiImageFrom
DisplayString,
swMultiImageSendUser
DisplayString,
swMultiImageFileName
DisplayString
}
swMultiImageInfoID OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The stacking section ID of the firmware image.
The stacking section ID = 256 * Unit ID + Image File ID."
::= { swMultiImageInfoEntry 1 }
swMultiImageVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The recorded downloaded firmware version."
::= { swMultiImageInfoEntry 2 }
swMultiImageSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The recorded downloaded firmware size."
::= { swMultiImageInfoEntry 3 }
swMultiImageUpdateTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The recorded firmware update time."
::= { swMultiImageInfoEntry 4 }
swMultiImageFrom OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..100))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The recorded IP address of the TFTP server"
::= { swMultiImageInfoEntry 5 }
swMultiImageSendUser OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The record of the user who downloaded the firmware."
::= { swMultiImageInfoEntry 6 }
swMultiImageFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When the system is set to boot from SD card, this object will display the recorded path name of the boot firmware file. "
::= { swMultiImageInfoEntry 7 }
-- -----------------------------------------------------------------------------
agentMultiCfgMgmt OBJECT IDENTIFIER ::= { agentBasicConfig 8 }
swMultiCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwMultiCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { agentMultiCfgMgmt 1 }
swMultiCfgInfoEntry OBJECT-TYPE
SYNTAX SwMultiCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information about multiple configuration files."
INDEX { swMultiCfgInfoID }
::= { swMultiCfgInfoTable 1 }
SwMultiCfgInfoEntry ::=
SEQUENCE {
swMultiCfgInfoID
INTEGER,
swMultiCfgVersion
DisplayString,
swMultiCfgSize
Integer32,
swMultiCFgUpdateTime
DisplayString,
swMultiCfgFrom
DisplayString,
swMultiCfgSendUser
DisplayString,
swMultiCfgFileName
DisplayString
}
swMultiCfgInfoID OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The section ID of the configuration files."
::= { swMultiCfgInfoEntry 1 }
swMultiCfgVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The recorded downloaded configuration version."
::= { swMultiCfgInfoEntry 2 }
swMultiCfgSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The recorded downloaded configuration size (in bytes).
"
::= { swMultiCfgInfoEntry 3 }
swMultiCFgUpdateTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The recorded configuration update time
displayed in string format, i.e. yyyy/mon/dd hh:mm:ss."
::= { swMultiCfgInfoEntry 4 }
swMultiCfgFrom OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..100))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The recorded IP address of the TFTP server."
::= { swMultiCfgInfoEntry 5 }
swMultiCfgSendUser OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The record of the user who downloaded the configuration file"
::= { swMultiCfgInfoEntry 6 }
swMultiCfgFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When the system is set to boot from SD card, this object displays the recorded path name of the boot configuration file. "
::= { swMultiCfgInfoEntry 7 }
-- -----------------------------------------------------------------------------
swMultiCfgCurrentUsed OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The indicated configuration file ID of the system currently in use."
::= { agentMultiCfgMgmt 2 }
swMultiCfgBootUp OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the configuration file ID which will take effect upon the next reboot."
::= { agentMultiCfgMgmt 3 }
-- -----------------------------------------------------------------------------
-- swMultiCfgCtrlTable
-- -----------------------------------------------------------------------------
swMultiCfgCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwMultiCfgCtrlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { agentMultiCfgMgmt 4 }
swMultiCfgCtrlEntry OBJECT-TYPE
SYNTAX SwMultiCfgCtrlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information about multiple configuration management."
INDEX { swMultiCfgCtrlID }
::= { swMultiCfgCtrlTable 1 }
SwMultiCfgCtrlEntry ::=
SEQUENCE {
swMultiCfgCtrlID
INTEGER,
swMultiCfgAction
INTEGER
}
swMultiCfgCtrlID OBJECT-TYPE
SYNTAX INTEGER{
cfgId-1(1),
cfgId-2(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The section ID of the configuration file."
::= { swMultiCfgCtrlEntry 1 }
swMultiCfgAction OBJECT-TYPE
SYNTAX INTEGER
{
active(1),
delete(2),
apply(3),
none(4),
config-as-bootup-cfg(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
save: Save configuration to active configuration ID when the parameter is omitted.
active: Set any valid configuration as the active configuration.
delete: Removes the configuration from the flash memory. This configuration
cannot be the active or current configuration file.
apply: Loads the indicated configuration file and applies it to the system.
config-as-bootup-cfg: Configured as the boot-up configuration by the indicated configuration(ID)."
::= { swMultiCfgCtrlEntry 2 }
-- -----------------------------------------------------------------------------
-- Add common severity control management
-- -----------------------------------------------------------------------------
systemSeverityControlMgmt OBJECT IDENTIFIER ::= { agentBasicConfig 9 }
systemSeverityTrapControl OBJECT-TYPE
SYNTAX AgentNotifyLevel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the level of trap severity control. The system has a severity level control
and each trap should have a severity control set. When trap events occur and its severity
is higher than the system severity control level, the trap works as defined. If the event
severity is lower than the system severity control level, the event is ignored as if it
did not occur."
::= { systemSeverityControlMgmt 1 }
systemSeverityLogControl OBJECT-TYPE
SYNTAX AgentNotifyLevel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the level of trap severity control. The system has a severity level control and
each trap should have a severity control set. When trap events occur and its severity is
higher than the system severity control level, the trap works as defined. If the event
severity is lower than the system severity control level, the event is ignored as if
it did not occur."
::= { systemSeverityControlMgmt 2 }
-- -----------------------------------------------------------------------------
-- agentTrustedHostMgmt
-- -----------------------------------------------------------------------------
agentTrustedHostMgmt OBJECT IDENTIFIER ::= { agentBasicConfig 10 }
agentTrustedHostTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentTrustedHostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the trusted host information."
::= { agentTrustedHostMgmt 1 }
agentTrustedHostEntry OBJECT-TYPE
SYNTAX AgentTrustedHostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information about the trusted hosts."
INDEX { agentTrustedHostIndex }
::= { agentTrustedHostTable 1 }
AgentTrustedHostEntry ::=
SEQUENCE {
agentTrustedHostIndex
INTEGER,
agentTrustedHostIPAddress
IpAddress,
agentTrustedHostRowStatus
RowStatus,
agentTrustedHostIPSubnetMask
IpAddress,
agentTrustedHostForSNMP
INTEGER,
agentTrustedHostForTELNET
INTEGER,
agentTrustedHostForSSH
INTEGER,
agentTrustedHostForHTTP
INTEGER,
agentTrustedHostForHTTPS
INTEGER,
agentTrustedHostForPING
INTEGER,
agentTrustedHostAddrType
InetAddressType,
agentTrustedHostAddr
InetAddress,
agentTrustedHostIPv6PrefixLen
INTEGER
}
agentTrustedHostIndex OBJECT-TYPE
SYNTAX INTEGER (1..30)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the trusted host entry."
::= { agentTrustedHostEntry 1 }
agentTrustedHostIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the IP address of the trusted host."
::= { agentTrustedHostEntry 2 }
agentTrustedHostRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the status of this entry. When creating a trusted host
entry, the IP address should also be set."
::= { agentTrustedHostEntry 3 }
agentTrustedHostIPSubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the IP subnet mask of the trusted host."
::= { agentTrustedHostEntry 4 }
agentTrustedHostForSNMP OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the trusted host for SNMP."
::= { agentTrustedHostEntry 5 }
agentTrustedHostForTELNET OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the trusted host for Telnet."
::= { agentTrustedHostEntry 6 }
agentTrustedHostForSSH OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the trusted host for SSH."
::= { agentTrustedHostEntry 7 }
agentTrustedHostForHTTP OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the trusted host for HTTP."
::= { agentTrustedHostEntry 8 }
agentTrustedHostForHTTPS OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the trusted host for HTTPS."
::= { agentTrustedHostEntry 9 }
agentTrustedHostForPING OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the trusted host for PING."
::= { agentTrustedHostEntry 10 }
agentTrustedHostAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of trusted host address as specified by
the 'agentTrustedHostAddr' object."
::= { agentTrustedHostEntry 11 }
agentTrustedHostAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the IP address of the trusted host."
::= { agentTrustedHostEntry 12 }
agentTrustedHostIPv6PrefixLen OBJECT-TYPE
SYNTAX INTEGER (1..128)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the IPv6 prefix length of the IPv6 trusted host."
::= { agentTrustedHostEntry 13 }
-- -----------------------------------------------------------------------------
-- agentTrustedHostDelAllState
-- -----------------------------------------------------------------------------
agentTrustedHostDelAllState OBJECT-TYPE
SYNTAX INTEGER{
none(1),
start(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to delete all trusted host entries."
::= { agentTrustedHostMgmt 2 }
-- -----------------------------------------------------------------------------
-- agentFDBMgmt
-- -----------------------------------------------------------------------------
agentFDBMgmt OBJECT IDENTIFIER ::= { agentBasicConfig 11 }
agentFDBClearAllState OBJECT-TYPE
SYNTAX INTEGER{
other(1),
start(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to clear all FDB entries."
::= { agentFDBMgmt 1 }
agentFDBClearByPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentFDBClearByPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Used to clear FDB entries by port."
::= { agentFDBMgmt 2 }
agentFDBClearByPortEntry OBJECT-TYPE
SYNTAX AgentFDBClearByPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is an entry of the agentFDBClearByPortTable."
INDEX { agentFDBClearPortIndex }
::= { agentFDBClearByPortTable 1 }
AgentFDBClearByPortEntry ::=
SEQUENCE {
agentFDBClearPortIndex
INTEGER,
agentFDBClearByPortAction
INTEGER
}
agentFDBClearPortIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the port number."
::= { agentFDBClearByPortEntry 1 }
agentFDBClearByPortAction OBJECT-TYPE
SYNTAX INTEGER{
other(1),
start(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether to clear FDB or not."
::= { agentFDBClearByPortEntry 2 }
agentFDBClearByVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentFDBClearByVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Used to clear FDB entries by port."
::= { agentFDBMgmt 3 }
agentFDBClearByVlanEntry OBJECT-TYPE
SYNTAX AgentFDBClearByVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is an entry of agentFDBClearByPortTable."
INDEX { agentFDBClearVid }
::= { agentFDBClearByVlanTable 1 }
AgentFDBClearByVlanEntry ::=
SEQUENCE {
agentFDBClearVid
VlanId,
agentFDBClearByVlanAction
INTEGER
}
agentFDBClearVid OBJECT-TYPE
SYNTAX VlanId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the VLAN-ID."
::= { agentFDBClearByVlanEntry 1 }
agentFDBClearByVlanAction OBJECT-TYPE
SYNTAX INTEGER{
other(1),
start(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether to clear the FDB or not."
::= { agentFDBClearByVlanEntry 2 }
agentFDBSecurityTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentFDBSecurityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Used to display the FDB entries that have been created by the security module."
::= { agentFDBMgmt 4}
agentFDBSecurityEntry OBJECT-TYPE
SYNTAX AgentFDBSecurityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is an entry of agentFDBSecurityTable."
INDEX {
agentFDBVid,
agentFDBMacAddress
}
::= { agentFDBSecurityTable 1 }
AgentFDBSecurityEntry ::=
SEQUENCE {
agentFDBVid
VlanId,
agentFDBMacAddress
MacAddress,
agentFDBPort
INTEGER,
agentFDBType
INTEGER,
agentFDBStatus
INTEGER,
agentFDBSecurityModule
INTEGER
}
agentFDBVid OBJECT-TYPE
SYNTAX VlanId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the VLAN-ID."
::= { agentFDBSecurityEntry 1 }
agentFDBMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the MAC address."
::= { agentFDBSecurityEntry 2 }
agentFDBPort OBJECT-TYPE
SYNTAX INTEGER(1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the port number."
::= { agentFDBSecurityEntry 3 }
agentFDBType OBJECT-TYPE
SYNTAX INTEGER{
dynamic(1),
static(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the MAC address type."
::= { agentFDBSecurityEntry 4 }
agentFDBStatus OBJECT-TYPE
SYNTAX INTEGER{
drop(1),
forward(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the MAC address's forwarding status."
::= { agentFDBSecurityEntry 5}
agentFDBSecurityModule OBJECT-TYPE
SYNTAX INTEGER{
dot1x(1),
wac(2),
jwac(3),
port-security(4),
mac-based-access-control(5),
compound-authentication(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to indicate which security module created the current MAC address.
dot1x: 802.1X.
wac: Web-based Access Control.
jwac: Web-Based Access Control extension for Japan.
port-security: Port Security.
mac-based-access-control: MAC-based Access Control.
compound-authentication: Compound Authentication."
::= { agentFDBSecurityEntry 6}
-- -----------------------------------------------------------------------------
-- agentARPMgmt
-- -----------------------------------------------------------------------------
agentARPMgmt OBJECT IDENTIFIER ::= { agentBasicConfig 12 }
agentARPClearAllState OBJECT-TYPE
SYNTAX INTEGER{
other(1),
start(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to clear all ARP entries."
::= { agentARPMgmt 1 }
-- -----------------------------------------------------------------------------
-- agentGratuitousARPMgmt
-- -----------------------------------------------------------------------------
agentGratuitousARPMgmt OBJECT IDENTIFIER ::={agentARPMgmt 2}
agentGratuitousARPSendIpifStatusUpState OBJECT-TYPE
SYNTAX INTEGER{
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is used to enable/disable sending of gratuitous ARP request
packets while the IPIF interface comes up. This is used to automatically
announce the interface's IP address to other nodes. By default,
the state is enabled, and only one ARP packet will be broadcast."
DEFVAL { enabled }
::={ agentGratuitousARPMgmt 1}
agentGratuitousARPSendDupIpDetectedState OBJECT-TYPE
SYNTAX INTEGER{
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is used to enable/disable the sending of gratuitous ARP request
packets while a duplicate IP is detected. By default, the state is enabled.
The duplicate IP detected state indicates that the system has received an ARP request
packet that was sent by an IP address that matches the system's own IP address.
In this case, the system knows that somebody out there is using an IP address
that is in conflict with the system. In order to reclaim the correct host
of this IP address, the system can send out the gratuitous ARP request
packet for this duplicate IP address."
DEFVAL { enabled }
::={ agentGratuitousARPMgmt 2}
agentGratuitousARPLearningState OBJECT-TYPE
SYNTAX INTEGER{
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is used to enable/disable learning of an ARP entry in the ARP
cache based on the received gratuitous ARP packet. If the switch
receives a gratuitous ARP request/reply packet and the sender's
IP address is in its ARP table, it should update the ARP entry.
By default, the state is disabled."
DEFVAL { disabled }
::={ agentGratuitousARPMgmt 3}
agentGratuitousARPTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentGratuitousARPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Gratuitous ARP Table Information."
::={ agentGratuitousARPMgmt 4}
agentGratuitousARPEntry OBJECT-TYPE
SYNTAX AgentGratuitousARPEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information from the Gratuitous ARP Table."
INDEX {
agentGratuitousARPInterfaceName
}
::={ agentGratuitousARPTable 1 }
AgentGratuitousARPEntry ::=
SEQUENCE {
agentGratuitousARPInterfaceName
DisplayString,
agentGratuitousARPPeriodicalSendInterval
INTEGER,
agentGratuitousARPTrapState
INTEGER,
agentGratuitousARPLogState
INTEGER
}
agentGratuitousARPInterfaceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the IP interface."
::={agentGratuitousARPEntry 1}
agentGratuitousARPPeriodicalSendInterval OBJECT-TYPE
SYNTAX INTEGER (0..65535)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is used to configure the interval for the periodic sending of
gratuitous ARP request packets.
0 means do not send gratuitous ARP request packets periodically."
DEFVAL { 0 }
::={agentGratuitousARPEntry 2}
agentGratuitousARPTrapState OBJECT-TYPE
SYNTAX INTEGER{
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This indicates the state of the gratuitous ARP trap. The switch can
trap the IP conflict events to inform the administrator.
By default, the trap is disabled."
DEFVAL { disabled }
::={agentGratuitousARPEntry 3}
agentGratuitousARPLogState OBJECT-TYPE
SYNTAX INTEGER{
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This indicates the state of the gratuitous Log trap. The switch can
log the IP conflict events to inform the administrator.
By default, the event log is enabled."
DEFVAL { enabled }
::={agentGratuitousARPEntry 4}
agentARPTotalARPEntries OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Used to display the total number of ARP entries."
::= { agentARPMgmt 3 }
agentARPRetryTimes OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This indicates the retry times of the ARP request."
::= { agentARPMgmt 4 }
-- -----------------------------------------------------------------------------
-- swMultiImageCtrlTable
-- -----------------------------------------------------------------------------
swMultiImageCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwMultiImageCtrlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { agentBasicConfig 13 }
swMultiImageCtrlEntry OBJECT-TYPE
SYNTAX SwMultiImageCtrlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information about multiple image management."
INDEX { swMultiImageCtrlID }
::= { swMultiImageCtrlTable 1 }
SwMultiImageCtrlEntry ::=
SEQUENCE {
swMultiImageCtrlID
INTEGER,
swMultiImageCtrlAction
INTEGER
}
swMultiImageCtrlID OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The stacking section ID of the firmware image.
The stacking section ID = 256 * Unit ID + Image File ID."
::= { swMultiImageCtrlEntry 1 }
swMultiImageCtrlAction OBJECT-TYPE
SYNTAX INTEGER{
config-as-bootup-fw(1),
delete(2),
none(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the running status of the image which is
specified by swMultiImageCtrlID and swMultiImageCtrlUnitID.
config-as-bootup-fw (1) - Configured as the bootup firmware by the indicated firmware(ID).
delete (2) - Delete the firmware by indicated firmware ID.
none (3) - No action.
"
::= { swMultiImageCtrlEntry 2 }
-- -----------------------------------------------------------------------------
agentOutOfBandDataBits OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the out-of-band data bits."
::= { agentBasicConfig 14 }
agentOutOfBandParityBits OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the out-of-band parity bits."
::= { agentBasicConfig 15 }
agentOutOfBandStopBits OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the out-of-band stop bits."
::= { agentBasicConfig 16 }
agentOutOfBandAutoLogoutConfig OBJECT-TYPE
SYNTAX INTEGER {
never(1),
minutes-2(2),
minutes-5(3),
minutes-10(4),
minutes-15(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the user to specify an out-of-band auto logout time."
::= { agentBasicConfig 17 }
-- -----------------------------------------------------------------------------
-- agentBscFileSystemMgmt
-- -----------------------------------------------------------------------------
agentBscFileSystemMgmt OBJECT IDENTIFIER ::= { agentBasicConfig 18 }
agentBscFileSystemTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentBscFileSystemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of MIB File System Basic Configuration entries supported
by the file update of this agent."
::= { agentBscFileSystemMgmt 1 }
agentBscFileSystemEntry OBJECT-TYPE
SYNTAX AgentBscFileSystemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A File System basic configuration entry that contains objects
describing a particular MIB supported by this agent."
INDEX { agentBscFileSystemIndex }
::= { agentBscFileSystemTable 1 }
AgentBscFileSystemEntry ::=
SEQUENCE {
agentBscFileSystemIndex
Integer32,
agentBscFileSystemDscr
DisplayString,
agentBscFileSystemServerAddr
IpAddress,
agentBscFileSystemServerIPv6Addr
Ipv6Address,
agentBscFileSystemServerFileName
DisplayString,
agentBscFileSystemDeviceDriverID
INTEGER,
agentBscFileSystemDeviceFileName
DisplayString,
agentBscFileSystemLoadType
INTEGER,
agentBscFileSystemCtrlUnitID
UnitList,
agentBscFileSystemBootUpImage
TruthValue,
agentBscFileSystemForceAgree
TruthValue,
agentBscFileSystemCtrl
INTEGER,
agentBscFileSystemInterfaceName
DisplayString,
agentBscFileSystemServerDomainName
DisplayString,
agentBscFileSystemIncrement
TruthValue,
agentBscFileSystemServerVrfName
DisplayString
}
agentBscFileSystemIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The table index for the file entry.
This object describes the file type.
runtime-code (1),
log-file (2),
cfg-file (3),
attack-log-file (7)"
::= { agentBscFileSystemEntry 1 }
agentBscFileSystemDscr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of the software file purpose in this entry."
::= { agentBscFileSystemEntry 2 }
agentBscFileSystemServerAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address where the file to be downloaded is located, or the IP address
where the file will be uploaded to."
::= { agentBscFileSystemEntry 3 }
agentBscFileSystemServerIPv6Addr OBJECT-TYPE
SYNTAX Ipv6Address
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv6 address where the file is to be downloaded from or uploaded to."
::= { agentBscFileSystemEntry 4 }
agentBscFileSystemServerFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the file to be downloaded from or uploaded to the TFTP server.
If agentBscFileSystemDeviceFileName is not set, the switch will default to using
the bootup file as the runtime image for the switch."
::= { agentBscFileSystemEntry 5 }
agentBscFileSystemDeviceDriverID OBJECT-TYPE
SYNTAX INTEGER {
none(1),
a(2),
b(3),
c(4),
d(5),
e(6),
f(7),
g(8),
h(9),
i(10),
j(11),
k(12),
l(13),
m(14),
n(15),
o(16),
p(17),
q(18),
r(19),
s(20),
t(21),
u(22),
v(23),
w(24),
x(25),
y(26),
z(27)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the drive of the device that the firmware to be uploaded/downloaded is located.
If none (1) is specified, the switch will default to the current drive."
::= { agentBscFileSystemEntry 6 }
agentBscFileSystemDeviceFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the file to be downloaded to the device, or uploaded from the
device. When downloading or uploading, the agentBscFileSystemServerFileName object must also be set."
::= { agentBscFileSystemEntry 7 }
agentBscFileSystemLoadType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
upload(2),
download(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the user to select a download or upload function for the file.
Note:
For systems that do not support changes to this object, setting a value for
this object will cause the system to return a bad-value error message.
"
::= { agentBscFileSystemEntry 8 }
agentBscFileSystemCtrlUnitID OBJECT-TYPE
SYNTAX UnitList
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies which unit of the switch stack the firmware image or configuration file should be downloaded from.
One or more units can be set in this list. Each bit from left to right represents the
switch from unit ID 1 to unit ID 12.
If this list is set to null it represents all stack switches."
::= { agentBscFileSystemEntry 9 }
agentBscFileSystemBootUpImage OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The result of the download will depend on whether the boot_up option has been specified.
Case 1: In the case of the master unit providing the file system and the slave unit
not providing the file system, when the boot_up parameter is specified, then the file will
be downloaded to the boot_up image on the slave. If the boot_up parameter is not specified,
then the file will not be downloaded to this slave unit.
Case 2: In the case of the master unit not providing the file system and the slave unit
providing the file system, when the boot_up parameter is specified, then the file will be downloaded
to the boot_up image on the slave unit. If boot_up is not specified, then the file will
not be downloaded to this slave unit.
Case 3: In the case of the master unit and the slave unit both supporting or not supporting the
file system, the file will be downloaded to the specified file on the slave unit. If boot_up
is specified, the downloaded file will be assigned as the boot_up image.
True: boot_up option is specified.
False: boot_up option is not specified.. "
::= { agentBscFileSystemEntry 10 }
agentBscFileSystemForceAgree OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the force_agree option is specified, the reboot command will be executed immediately
without any further confirmation from the user.
True: force_agree option is specified.
False: force_agree option is not specified.. "
::= { agentBscFileSystemEntry 11 }
agentBscFileSystemCtrl OBJECT-TYPE
SYNTAX INTEGER {
other(1),
inactive(2),
start(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the user to download runtime software. The settings
will take effect when the system restarts. See Note (1) below
Note 1:
For systems which do not support value changes to this object,
setting these values will cause the system to return a bad-value error message
start (3) - activate firmware.
"
::= { agentBscFileSystemEntry 12 }
agentBscFileSystemInterfaceName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..12))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This node is used to specify the interface name when agentBscFileSystemServerIPv6Addr
is the local link address."
::= { agentBscFileSystemEntry 13 }
agentBscFileSystemServerDomainName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the domain name of the TFTP server."
::= { agentBscFileSystemEntry 14 }
agentBscFileSystemIncrement OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If increment is specified, then the existing configuration will not be cleared before applying
of the new configuration. If it is not specified, then the existing configuration will be cleared
before applying of the new configuration.
True : keep valid
False : erase. "
::= { agentBscFileSystemEntry 15 }
agentBscFileSystemServerVrfName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..12))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the VRF name of the TFTP server.Input string 'reserved'
for the global space."
::= { agentBscFileSystemEntry 16}
-- --------------------------------------------------------------------------------
agentBscFileSystemSaveConfigDriverID OBJECT-TYPE
SYNTAX INTEGER {
none(1),
a(2),
b(3),
c(4),
d(5),
e(6),
f(7),
g(8),
h(9),
i(10),
j(11),
k(12),
l(13),
m(14),
n(15),
o(16),
p(17),
q(18),
r(19),
s(20),
t(21),
u(22),
v(23),
w(24),
x(25),
y(26),
z(27)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The drive on the device that the configuration file is will be saved to.
If none (1) is specified, the switch places the file on the current drive by default."
::= { agentBscFileSystemMgmt 2 }
agentBscFileSystemSaveConfigFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the configuration file that will be saved to the device.
When agentBscFileSystemSaveCfg is set to cfg (2), and if the agentBscFileSystemSaveConfigFileName
is not null, the configuration file will be saved to the set file name.
If set to null, the configuration file will be saved to the boot_up CFG file. "
::= { agentBscFileSystemMgmt 3 }
agentBscFileSystemSaveCfg OBJECT-TYPE
SYNTAX INTEGER {
other(1),
cfg(2),
log(3),
all(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This indicates the method of saving information to the NV-RAM of the device.
other (1) - None of the following.
cfg (2) - Save configuration.
log (3) - Save log.
all (4) - Save both ( active configuration and log)."
::= { agentBscFileSystemMgmt 4 }
-- -----------------------------------------------------------------------------
agentFileSystemConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentFileSystemConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table indicates the information about the bootup files."
::= { agentBscFileSystemMgmt 5 }
agentFileSystemConfigEntry OBJECT-TYPE
SYNTAX AgentFileSystemConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of information about the bootup files for each unit of the switch stack."
INDEX { agentFileSystemUnit }
::= { agentFileSystemConfigTable 1 }
AgentFileSystemConfigEntry ::=
SEQUENCE {
agentFileSystemUnit
Integer32,
agentFileSystemDriverID
INTEGER,
agentFileSystemBootImage
DisplayString,
agentFileSystemBootConfig
DisplayString,
agentFileSystemActConfig
DisplayString
}
agentFileSystemUnit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit ID."
::= { agentFileSystemConfigEntry 1 }
agentFileSystemDriverID OBJECT-TYPE
SYNTAX INTEGER {
none(1),
a(2),
b(3),
c(4),
d(5),
e(6),
f(7),
g(8),
h(9),
i(10),
j(11),
k(12),
l(13),
m(14),
n(15),
o(16),
p(17),
q(18),
r(19),
s(20),
t(21),
u(22),
v(23),
w(24),
x(25),
y(26),
z(27)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The drive on the device that the configuration file will be saved to.
If none (1) is specified, the switch will place the file to the current drive by default."
::= { agentFileSystemConfigEntry 2 }
agentFileSystemBootImage OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When displayed, it shows the current bootup image file name.
When set, the set name will be set as the bootup image."
::= { agentFileSystemConfigEntry 3 }
agentFileSystemBootConfig OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When displayed, it shows the current bootup configuration file name.
When set, the set name will be set as the bootup configuration."
::= { agentFileSystemConfigEntry 4 }
agentFileSystemActConfig OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When displayed, it shows null.
When set, the set name will be active at once, but the set name
will not be set as the bootup configuration."
::= { agentFileSystemConfigEntry 5 }
-- -----------------------------------------------------------------------------
agentReboot OBJECT-TYPE
SYNTAX INTEGER {
none(1),
start(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to restart the switch."
::= { agentBasicConfig 19 }
agentReset OBJECT-TYPE
SYNTAX INTEGER {
none(1),
config(2),
system(3),
reset(4),
system-exclude-vlan(5),
system-exclude-ip(6),
system-exclude-vlan-ip(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to reset all switch parameters.
none (1): No action. This is the default value of this object.
config (2): All parameters are reset to default settings.
The device will neither save nor reboot.
system (3): All parameters are reset to default settings.
The switch will then do a factory reset, save, and reboot.
reset (4) : All parameters will be reset to default settings except for the
IP address, user account, and history log.
The device will neither save nor reboot.
system-exclude-vlan(5) : All parameters are reset to default settings except for VLAN.
The switch will then save its settings and reboot.
system-exclude-ip(6) : All parameters are reset to default settings except IP address.
The switch will then save its settings and reboot.
system-exclude-vlan-ip(7): All parameters are reset to default settings except VLAN and IP address.
The switch will then save its settings and reboot.
"
::= { agentBasicConfig 20 }
-- -----------------------------------------------------------------------------
-- agentFTPFileTable
-- -----------------------------------------------------------------------------
agentFTPFileTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentFTPFileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of the MIB Basic Config entries support files updated by this agent."
::= { agentBasicConfig 21 }
agentFTPFileEntry OBJECT-TYPE
SYNTAX AgentFTPFileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A basic configuration entry containing the objects describing a particular MIB
supported by this agent."
INDEX { agentFTPFileIndex }
::= { agentFTPFileTable 1 }
AgentFTPFileEntry ::=
SEQUENCE {
agentFTPFileIndex
Integer32,
agentFTPFileDscr
DisplayString,
agentFTPFileLoadType
INTEGER,
agentFTPFileAddr
IpAddress,
agentFTPTCPPort
INTEGER,
agentFTPFileName
DisplayString,
agentFTPUserName
DisplayString,
agentFTPPassword
DisplayString,
agentFTPFileCtrlID
INTEGER,
agentFTPFileBIncrement
TruthValue,
agentFTPFileCtrl
INTEGER,
agentFTPFileBootUpImage
TruthValue,
agentFTPFileForceAgree
TruthValue,
agentFTPFileIPv6Addr
DisplayString,
agentFTPFileInterfaceName
DisplayString,
agentFTPFileUnitID
UnitList
}
agentFTPFileIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The table index for the file entry. This object describes the file type
runtime-code (1),
log-file (2),
cfg-file (3)"
::= { agentFTPFileEntry 1 }
agentFTPFileDscr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The description of the software file purpose in this entry.
Note: For systems which do not support changes to this object, setting a value for
this object will cause the system to return bad-value error messages."
::= { agentFTPFileEntry 2 }
agentFTPFileLoadType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
upload(2),
download(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object provides the user with a choice of uploading or downloading the selected file.
Note: For systems which do not support a change of this object, setting a value to this object
will cause the system to return bad-value error messages."
::= { agentFTPFileEntry 3 }
agentFTPFileAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address that the file to be downloaded is located on, or the IP address
where the file will be uploaded to."
::= { agentFTPFileEntry 4 }
agentFTPTCPPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TCP port number being used to establish the command connection."
::= { agentFTPFileEntry 5 }
agentFTPFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the file to be downloaded from, or uploaded to, the FTP server."
::= { agentFTPFileEntry 6 }
agentFTPUserName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the user name to enter in upload/download. "
::= { agentFTPFileEntry 7 }
agentFTPPassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the password to enter for an upload/download."
::= { agentFTPFileEntry 8 }
agentFTPFileCtrlID OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The section ID of the firmware image or configuration file.
A value of 0 indicates the boot-up firmware image or configuration file."
::= { agentFTPFileEntry 9 }
agentFTPFileBIncrement OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the previous configuration will remain
valid or not after downloading the configuration file.
True: Keep valid
False: Erase. "
::= { agentFTPFileEntry 10 }
agentFTPFileCtrl OBJECT-TYPE
SYNTAX INTEGER {
other(1),
start(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object gives the user the option to download runtime software. The setting will take effect
when the system restarts. See Note (1) below
Note 1:
For systems which do not support changes to this object, setting a value for this object
will cause the system to return bad-value error messages. "
::= { agentFTPFileEntry 11 }
agentFTPFileBootUpImage OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether to set the special file as a boot up file or not.
True: The boot-up option is specified.
False: The boot-up option is not specified."
::= { agentFTPFileEntry 12 }
agentFTPFileForceAgree OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the force-agree option is specified, the reboot command will be executed
immediately without any further confirmation from the user.
True: Force-agree option is specified.
False: Force-agree option is not specified."
::= { agentFTPFileEntry 13 }
agentFTPFileIPv6Addr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv6 address where the file is to be downloaded from or uploaded to."
::= { agentFTPFileEntry 14 }
agentFTPFileInterfaceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This node is used to specify the interface name when agentFTPFileIPv6Addr
is the local link address. "
::= { agentFTPFileEntry 15 }
agentFTPFileUnitID OBJECT-TYPE
SYNTAX UnitList
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies which unit of the switch stack the firmware image or configuration
file should be downloaded from. One or more units can be set in this list. Each
bit from left to right represents the switch from unit ID 1 to unit ID 12.If this
list is set to null it represents all stack switches."
::= { agentFTPFileEntry 16 }
-- -----------------------------------------------------------------------------
-- agentSnmpTrapState
-- -----------------------------------------------------------------------------
agentSnmpTrapState OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if the SNMP trap is enabled or disabled."
::= { agentBasicConfig 22 }
-- -----------------------------------------------------------------------------
-- agentOutOfBandMgmt
-- -----------------------------------------------------------------------------
agentOutOfBandMgmt OBJECT IDENTIFIER ::= { agentBasicConfig 23 }
agentOutOfBandMgmtState OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disables the interface."
::= { agentOutOfBandMgmt 1 }
agentOutOfBandMgmtIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address for out of band management. This object can only take the
value of the unicast IP address."
::= { agentOutOfBandMgmt 2 }
agentOutOfBandMgmtSubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP net mask for out of band management."
::= { agentOutOfBandMgmt 3 }
agentOutOfBandMgmtGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The gateway for out of band management. "
::= { agentOutOfBandMgmt 4 }
agentOutOfBandMgmtLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
link-up(1),
link-down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Link status for out of band management."
::= { agentOutOfBandMgmt 5 }
-- -----------------------------------------------------------------------------
-- agentTrapMgmt
-- -----------------------------------------------------------------------------
agentTrapMgmt OBJECT IDENTIFIER ::= { agentBasicConfig 24 }
agentTrapColdStart OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled (1), whenever the device detects a cold start event,
a trap will be sent out."
::= { agentTrapMgmt 1 }
agentTrapWarmStart OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled (1), whenever the device detects a warm start event,
a trap will be sent out."
::= { agentTrapMgmt 2 }
agentTrapRmonRisingAlarm OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled (1), whenever the device detects a RMON rising alarm
event , a trap will be sent out."
::= { agentTrapMgmt 3 }
agentTrapRmonFallingAlarm OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled (1), whenever the device detects a RMON falling alarm
event, a trap will be sent out."
::= { agentTrapMgmt 4 }
agentTrapCfgSave OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled (1), whenever the device detects a configuration saving
completed event, a trap will be sent out."
::= { agentTrapMgmt 5 }
agentTrapCfgUpload OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled (1), whenever the device detects a configuration
uploading completed event, a trap will be sent out."
::= { agentTrapMgmt 6 }
agentTrapCfgDownload OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled (1), whenever the device detects a configuration
downloading completed event, a trap will be sent out"
::= { agentTrapMgmt 7 }
-- -----------------------------------------------------------------------------
-- agentFTPFileSystemTable
-- -----------------------------------------------------------------------------
agentFTPFileSystemTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentFTPFileSystemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The FTP management table for the file system"
::= { agentBasicConfig 25 }
agentFTPFileSystemEntry OBJECT-TYPE
SYNTAX AgentFTPFileSystemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A File System basic configuration entry that contains objects
describing a particular MIB supported by this agent."
INDEX { agentFTPFileSystemIndex }
::= { agentFTPFileSystemTable 1 }
AgentFTPFileSystemEntry ::=
SEQUENCE {
agentFTPFileSystemIndex
Integer32,
agentFTPFileSystemDscr
DisplayString,
agentFTPFileSystemLoadType
INTEGER,
agentFTPFileSystemAddressType
InetAddressType,
agentFTPFileSystemAddress
InetAddress,
agentFTPFileSystemTCPPort
INTEGER,
agentFTPFileSystemServerFileName
DisplayString,
agentFTPFileSystemDeviceFileName
DisplayString,
agentFTPFileSystemUserName
DisplayString,
agentFTPFileSystemPassword
DisplayString,
agentFTPFileSystemCtrlUnitID
UnitList,
agentFTPFileSystemBootUpImage
TruthValue,
agentFTPFileSystemCtrl
INTEGER,
agentFTPFileSystemVrfName
DisplayString
}
agentFTPFileSystemIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table index for the file entry."
::= { agentFTPFileSystemEntry 1 }
agentFTPFileSystemDscr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of the software file purpose in this entry."
::= { agentFTPFileSystemEntry 2 }
agentFTPFileSystemLoadType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
upload(2),
download(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the user to select a download or upload function for the file."
::= { agentFTPFileSystemEntry 3 }
agentFTPFileSystemAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The address type of agentFTPFileSystemAddress."
::= { agentFTPFileSystemEntry 4 }
agentFTPFileSystemAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the FTP server address."
::= {agentFTPFileSystemEntry 5}
agentFTPFileSystemTCPPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TCP port number being used to establish the control connection."
::= { agentFTPFileSystemEntry 6 }
agentFTPFileSystemServerFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the file to be downloaded from or uploaded to the FTP server."
::= { agentFTPFileSystemEntry 7 }
agentFTPFileSystemDeviceFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the file to be downloaded to the device, or uploaded from the
device.
If agentFTPFileSystemDeviceFileName is not set, the switch will default to
the bootup file."
::= { agentFTPFileSystemEntry 8 }
agentFTPFileSystemUserName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the user name to access the FTP server."
::= { agentFTPFileSystemEntry 9 }
agentFTPFileSystemPassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the password to access the FTP server."
::= { agentFTPFileSystemEntry 10 }
agentFTPFileSystemCtrlUnitID OBJECT-TYPE
SYNTAX UnitList
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies which unit of the switch stack the firmware image or configuration
file should be downloaded from. One or more units can be set in this list. Each
bit from left to right represents the switch from unit ID 1 to unit ID 12.If this
list is set to null it represents all stack switches."
::= { agentFTPFileSystemEntry 11 }
agentFTPFileSystemBootUpImage OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether to set the special file as the boot up file or not.
True: The boot-up option is specified.
False: The boot-up option is not specified."
::= { agentFTPFileSystemEntry 12 }
agentFTPFileSystemCtrl OBJECT-TYPE
SYNTAX INTEGER {
other(1),
start(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the user to execute an FTP download/upload."
::= { agentFTPFileSystemEntry 13 }
agentFTPFileSystemVrfName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..12))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the VRF name of the FTP server.Input string 'reserved'
for the global space."
::= { agentFTPFileSystemEntry 14 }
-- -----------------------------------------------------------------------------
-- agentBscCMDLogState
-- -----------------------------------------------------------------------------
agentBscCMDLogState OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the command logging state."
::= { agentBasicConfig 26 }
-- -----------------------------------------------------------------------------
-- agentBscBroadcastPingReplyState
-- -----------------------------------------------------------------------------
agentBscBroadcastPingReplyState OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the broadcast ping reply state."
::= { agentBasicConfig 27 }
-- -----------------------------------------------------------------------------
-- agentBscTftpConfigMgmt
-- -----------------------------------------------------------------------------
agentBscTftpConfigMgmt OBJECT IDENTIFIER ::= { agentBasicConfig 28 }
agentBscTftpCfgFirmwareFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The firmware pathname that needs to be downloaded/uploaded from/to the TFTP server."
::= { agentBscTftpConfigMgmt 1 }
agentBscTftpCfgConfigFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The configuration pathname that needs to be downloaded/uploaded from/to the TFTP server."
::= { agentBscTftpConfigMgmt 2 }
agentBscTftpCfgLogFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The log pathname that needs to be uploaded to the TFTP server."
::= { agentBscTftpConfigMgmt 3 }
agentBscTftpCfgAttackLogFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The attack log pathname that needs to be uploaded to the TFTP server."
::= { agentBscTftpConfigMgmt 4 }
agentBscTftpCfgCertificateFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The certificate pathname that needs to be downloaded from the TFTP server."
::= { agentBscTftpConfigMgmt 5 }
agentBscTftpCfgKeyFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The key pathname that needs to be downloaded from the TFTP server."
::= { agentBscTftpConfigMgmt 6 }
agentBscTftpCfgTechSuooprtFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The technique's support information pathname that needs to be uploaded to the TFTP server."
::= { agentBscTftpConfigMgmt 7 }
agentBscTftpCfgDebugLogFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The debug log pathname that needs to be uploaded to the TFTP server."
::= { agentBscTftpConfigMgmt 8 }
agentBscTftpCfgSIMFirmwareFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The firmware pathname that needs to be downloaded/uploaded from/to the TFTP server when it is SIM enabled."
::= { agentBscTftpConfigMgmt 9 }
agentBscTftpCfgSIMConfigFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The configuration pathname that needs to be downloaded/uploaded from/to the TFTP server when it is SIM enabled."
::= { agentBscTftpConfigMgmt 10 }
agentBscTftpCfgSIMLogFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The log pathname that needs to be uploaded to the TFTP server when it is SIM enabled."
::= { agentBscTftpConfigMgmt 11 }
agentBscTftpCfgServerIPAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv4 address of the TFTP server."
::= { agentBscTftpConfigMgmt 12 }
agentBscTftpCfgServerIPv6Addr OBJECT-TYPE
SYNTAX Ipv6Address
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPv6 address of the TFTP server."
::= { agentBscTftpConfigMgmt 13 }
agentBscTftpCfgServerDomainName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The domain name of the TFTP server."
::= { agentBscTftpConfigMgmt 14 }
-- -----------------------------------------------------------------------------
-- agentBscCommunityEncryptionState
-- -----------------------------------------------------------------------------
agentBscCommunityEncryptionState OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the encryption state on the SNMP community string."
::= { agentBasicConfig 29 }
-- -----------------------------------------------------------------------------
-- agentSnmpUdpPort
-- -----------------------------------------------------------------------------
agentSnmpUdpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the snmp udp port number."
::= { agentBasicConfig 30 }
-- -----------------------------------------------------------------------------
-- agentResponseBroadcastRequest
-- -----------------------------------------------------------------------------
agentResponseBroadcastRequest OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the response broadcast request state."
::= { agentBasicConfig 31 }
-- -----------------------------------------------------------------------------
-- agentIpProtocolConfig
-- -----------------------------------------------------------------------------
agentIpProtoConfig OBJECT IDENTIFIER ::= { agentGeneralMgmt 3 }
agentIpNumOfIf OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of IP interfaces supported by this agent."
::= { agentIpProtoConfig 1 }
agentIpTftpServerAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"The IP address of the TFTP Server."
::= { agentIpProtoConfig 2 }
agentIpGetIpFrom OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
bootp(3),
dhcp(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if the agent will get its system IP address
from a Bootp/DHCP server at start up."
::= { agentIpProtoConfig 3 }
agentIpAutoconfig OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the status of automatically getting the configuration information
from a TFTP server connected to the device."
::= { agentIpProtoConfig 4 }
agentIpAutoconfigTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This timer is used to limit the length of time for getting the configuration
information from a TFTP server connected to the device."
::= { agentIpProtoConfig 5 }
-- End of agentIpIfTable
-- -----------------------------------------------------------------------------
-- agentIptrapMangerTable
-- -----------------------------------------------------------------------------
agentIpTrapManager OBJECT IDENTIFIER ::= { agentGeneralMgmt 4 }
-- agentIpTrapManagerTable OBJECT-TYPE-
-- SYNTAX SEQUENCE OF AgentIpTrapManagerEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "A list of trap managers that the SNMP traps will be sent to."
-- ::= { agentIpTrapManager 1 }
-- agentIpTrapManagerEntry OBJECT-TYPE
-- SYNTAX AgentIpTrapManagerEntry
-- MAX-ACCESS not-accessible
-- STATUS obsolete
-- DESCRIPTION
-- "Each entry contains the particular trap manager settings."
-- INDEX { agentIpTrapManagerIpAddr }
-- ::= { agentIpTrapManagerTable 1 }
-- -----------------------------------------------------------------------------
agentTrapManagerTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentTrapManagerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of trap managers that the SNMP traps will be sent to."
::= { agentIpTrapManager 2 }
agentTrapManagerEntry OBJECT-TYPE
SYNTAX AgentTrapManagerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry contains the particular trap manager's settings."
INDEX { agentTrapManagerIndex }
::= { agentTrapManagerTable 1 }
AgentTrapManagerEntry ::=
SEQUENCE {
agentTrapManagerIndex
INTEGER,
agentTrapManagerIpAddr
IpAddress,
agentTrapManagerComm
DisplayString,
agentTrapManagerMsgVer
INTEGER,
agentTrapManagerStatus
INTEGER,
agentTrapManagerUdpPort
INTEGER
}
agentTrapManagerIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A value that uniquely identifies trapDestEntry."
::= { agentTrapManagerEntry 1 }
agentTrapManagerIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination IP address for SNMP traps."
::= { agentTrapManagerEntry 2 }
agentTrapManagerComm OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The community string used to encode SNMP trap packets being sent to the trap
manager."
::= { agentTrapManagerEntry 3 }
agentTrapManagerMsgVer OBJECT-TYPE
SYNTAX INTEGER {
snmpAgentVersionDependent(1),
v1Trap(2),
v2Trap(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the version of trap packets that will be sent to
this trap manager. The default setting is SNMP Agent Version Dependent.
Note:
Because some of these functions will be limited by the support of
the system in question, some selected items may be invalid. If one
of these items is selected, a bad value error message will prompt
the user.
"
::= { agentTrapManagerEntry 4 }
agentTrapManagerStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether or not the trap should be sent to
the trap manager."
::= { agentTrapManagerEntry 5 }
agentTrapManagerUdpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Trap udp port number."
::= { agentTrapManagerEntry 6 }
-- -----------------------------------------------------------------------------
-- agentPortTrapStateTable
-- -----------------------------------------------------------------------------
agentPortTrapStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentPortTrapStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Use to Set/Get per port trap state."
::= { agentIpTrapManager 3 }
agentPortTrapStateEntry OBJECT-TYPE
SYNTAX AgentPortTrapStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is an entry of the agentPortTrapStateTable."
INDEX { agentTrapStatePortIndex }
::= { agentPortTrapStateTable 1 }
AgentPortTrapStateEntry ::=
SEQUENCE {
agentTrapStatePortIndex
INTEGER,
agentPortTrapState
INTEGER
}
agentTrapStatePortIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the port number."
::= { agentPortTrapStateEntry 1 }
agentPortTrapState OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the port trap status."
::= { agentPortTrapStateEntry 2 }
-- -----------------------------------------------------------------------------
-- Add for Slip_Console mode swtich 11-9-2001 WindChen
-- -----------------------------------------------------------------------------
-- agentConsoleModeManager OBJECT IDENTIFIER ::= { agentGeneralMgmt 5 }
-- -----------------------------------------------------------------------------
-- Slip Mode Manager
-- -----------------------------------------------------------------------------
-- agentSlipModeManager OBJECT IDENTIFIER ::= { agentGeneralMgmt 6 }
-- -----------------------------------------------------------------------------
-- Add common trap management
-- -----------------------------------------------------------------------------
agentNotify OBJECT IDENTIFIER ::= { agentGeneralMgmt 7 }
agentNotifMgmt OBJECT IDENTIFIER ::= { agentNotify 1 }
agentNotifFirmware OBJECT IDENTIFIER ::= { agentNotify 2 }
agentNotifyPrefix OBJECT IDENTIFIER ::= { agentNotifFirmware 0 }
-- -----------------------------------------------------------------------------
-- agentNotifMgmt
-- -----------------------------------------------------------------------------
-- systemSeverityControl OBJECT-TYPE
-- SYNTAX AgentNotifyLevel
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Indicates the level of trap severity control. The system has a severity level control
-- and each trap should have a severity control set. When trap events occur and its severity
-- is higher than the system severity control level, the trap works as defined. If the event
-- severity is lower than the system severity control level, the event is ignored as if it did not occur.
-- "
-- ::= { agentNotifMgmt 1 }
notifFirmwareMgmt OBJECT IDENTIFIER ::= { agentNotifMgmt 2 }
-- -----------------------------------------------------------------------------
-- agentNotifFirmware OBJECT IDENTIFIER ::= { agentNotifyPrefix 0 }
-- -----------------------------------------------------------------------------
-- agentNotifFirmware
-- -----------------------------------------------------------------------------
agentsystemRestart NOTIFICATION-TYPE
OBJECTS {
trapInfosystemRestart
}
STATUS current
DESCRIPTION
"This trap contains the reboot information."
::= { agentNotifyPrefix 1 }
agentSaveToNVRAM NOTIFICATION-TYPE
OBJECTS { unitID
}
STATUS current
DESCRIPTION
"This trap is sent whenever all the device configuration has been saved to NV-RAM."
::= { agentNotifyPrefix 2 }
agentFileTransferStatusChange NOTIFICATION-TYPE
OBJECTS {
unitID,
agentStatusFileTransfer
}
STATUS current
DESCRIPTION "File transfer status change notification."
::= { agentNotifyPrefix 3 }
agentSetToFactoryDefault NOTIFICATION-TYPE
OBJECTS { unitID
}
STATUS current
DESCRIPTION
"This trap is sent whenever the 'set to factory default' setting has been processed. "
::= { agentNotifyPrefix 4 }
agentGratuitousARPTrap NOTIFICATION-TYPE
OBJECTS {
agentGratuitousARPIpAddr,
agentGratuitousARPMacAddr,
agentGratuitousARPPortNumber,
agentGratuitousARPInterfaceName
}
STATUS current
DESCRIPTION
"This trap is sent when there is an IP address conflict."
::={agentNotifyPrefix 5}
agentLoginFailTrap NOTIFICATION-TYPE
OBJECTS {
agentLoginType,
agentLoginAAAMethod,
agentLoginUserName,
agentLoginIpAddr,
agentLoginMacAddr,
agentLoginAAAServerAddr,
agentLoginFailInfo
}
STATUS current
DESCRIPTION
"The trap is sent when a login has failed through one of the login types (console, Telnet, web, SSL or SSH)."
::={agentNotifyPrefix 6}
agentFirmwareUpgrade NOTIFICATION-TYPE
OBJECTS {
swMultiImageVersion
}
STATUS current
DESCRIPTION
"This trap is sent when the process of upgrading the firmware via SNMP has finished."
::= { agentNotifyPrefix 7 }
agentAccessFlashFailed NOTIFICATION-TYPE
OBJECTS {
agentAccessFlashOper,
agentAccessFlashAddr
}
STATUS current
DESCRIPTION
"The trap is sent when access to the flash fails."
::={agentNotifyPrefix 8}
agentCfgOperCompleteTrap NOTIFICATION-TYPE
OBJECTS {
unitID,
agentCfgOperate,
agentLoginUserName
}
STATUS current
DESCRIPTION
"The trap is sent when the configuration is completely saved, uploaded
or downloaded."
::={agentNotifyPrefix 9}
-- -----------------------------------------------------------------------------
-- agentNotifEquipment
-- -----------------------------------------------------------------------------
-- -----------------------------------------------------------------------------
-- notificationBindings
-- -----------------------------------------------------------------------------
notificationBindings OBJECT IDENTIFIER ::= { agentNotifFirmware 1 }
unitID OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The unit ID of the device which triggered the event."
::= { notificationBindings 1 }
trapInfosystemRestart OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the last time the device rebooted.
"
::= { notificationBindings 2 }
agentGratuitousARPIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"A duplicate IP address with the switch already exists."
::={notificationBindings 3}
agentGratuitousARPMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object is the MAC address of the device which has the duplicate IP address."
::={notificationBindings 4}
agentGratuitousARPPortNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This indicates the portNum with a string.
For example, if the device is in standalone mode, and the port
number is 23, the string should be 23.
If the device is in stacking mode, and the unit ID is 2, and the
port number is 3, the string should be 2:3.
"
::={notificationBindings 5}
agentLoginType OBJECT-TYPE
SYNTAX INTEGER {
console(1),
telnet(2),
web(3),
ssl(4),
ssh(5)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The type is the user login method type."
::= { notificationBindings 6 }
agentLoginAAAMethod OBJECT-TYPE
SYNTAX INTEGER {
none(1),
local(2),
server(3)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This method is the AAA login method."
::= { notificationBindings 7 }
agentLoginUserName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object is the name of the user that failed to login to the switch."
::= { notificationBindings 8 }
agentLoginIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object is the login type from the IP address."
::= { notificationBindings 9 }
agentLoginMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object is the login type from a MAC address."
::= { notificationBindings 10 }
agentLoginAAAServerAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object is the login type through a console authenticated by an AAA server."
::= { notificationBindings 11 }
agentLoginFailInfo OBJECT-TYPE
SYNTAX INTEGER {
other(1),
authenticate-fail(2),
server-timeout(3)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object indicates the reason for the login failure."
::= { notificationBindings 12 }
agentAccessFlashOper OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object indicates the operation of the access flash failure."
::= { notificationBindings 13 }
agentAccessFlashAddr OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object indicates the address of the access flash failure."
::= { notificationBindings 14 }
agentCfgOperate OBJECT-TYPE
SYNTAX INTEGER {
save(1),
upload(2),
download(3)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This object indicates the operation type of the configuration."
::= { notificationBindings 15 }
END