mibs/MIBS/dlink/DLINKSW-ENTITY-EXT-MIB
2023-12-05 12:25:34 +01:00

917 lines
34 KiB
Plaintext

-- *****************************************************************
-- DLINKSW-ENTITY-EXT-MIB.mib : D-Link Entity Extensions MIB
--
-- Copyright (c) 2013 D-Link Corporation, all rights reserved.
--
-- *****************************************************************
DLINKSW-ENTITY-EXT-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Integer32
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
dlinkIndustrialCommon
FROM DLINK-ID-REC-MIB;
dlinkSwEntityExtMIB MODULE-IDENTITY
LAST-UPDATED "201309060000Z"
ORGANIZATION "D-Link Corp."
CONTACT-INFO
" D-Link Corporation
Postal: No. 289, Sinhu 3rd Rd., Neihu District,
Taipei City 114, Taiwan, R.O.C
Tel: +886-2-66000123
E-mail: tsd@dlink.com.tw
"
DESCRIPTION
"This MIB module provides essential information about the system
and defines the managed objects that support the monitoring of alarms
generated by physical entities, including temperature sensors, fans
and power supplies.
"
REVISION "201309060000Z"
DESCRIPTION
"Add dEntityExtFactoryResetButton to support factory reset button trap."
REVISION "201303130000Z"
DESCRIPTION
"This is the first version of this MIB."
::= { dlinkIndustrialCommon 5 }
-- -----------------------------------------------------------------------------
dEntityExtNotifications OBJECT IDENTIFIER ::= { dlinkSwEntityExtMIB 0 }
dEntityExtObjects OBJECT IDENTIFIER ::= { dlinkSwEntityExtMIB 1 }
dEntityExtConformance OBJECT IDENTIFIER ::= { dlinkSwEntityExtMIB 2 }
-- -----------------------------------------------------------------------------
dEntityExtEnvObjects OBJECT IDENTIFIER ::= { dEntityExtObjects 1 }
dEntityExtEnvTempTable OBJECT-TYPE
SYNTAX SEQUENCE OF DEntityExtEnvTempEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table consists of a list of temperature information."
::= { dEntityExtEnvObjects 1 }
dEntityExtEnvTempEntry OBJECT-TYPE
SYNTAX DEntityExtEnvTempEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry represents the temperature status of a testpoint.
"
INDEX {
dEntityExtEnvTempUnitId,
dEntityExtEnvTempIndex
}
::= { dEntityExtEnvTempTable 1 }
DEntityExtEnvTempEntry ::= SEQUENCE {
dEntityExtEnvTempUnitId Unsigned32,
dEntityExtEnvTempIndex Integer32,
dEntityExtEnvTempDescr DisplayString,
dEntityExtEnvTempCurrent Integer32,
dEntityExtEnvTempThresholdLow Integer32,
dEntityExtEnvTempThresholdHigh Integer32,
dEntityExtEnvTempStatus INTEGER
}
dEntityExtEnvTempUnitId OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the unit (stacking device) or slot (chassis
device) ID at which the testpoint is located."
::= { dEntityExtEnvTempEntry 1 }
dEntityExtEnvTempIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is used to uniquely identify the testpoint
within a unit/slot.
This index is for SNMP purposes only, and has no intrinsic meaning."
::= { dEntityExtEnvTempEntry 2 }
dEntityExtEnvTempDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides human-sensible identification for the testpoint.
e.g. 'Inlet', 'Center', 'Outlet'.
"
::= { dEntityExtEnvTempEntry 3 }
dEntityExtEnvTempCurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the current measurement of the testpoint."
::= { dEntityExtEnvTempEntry 4 }
dEntityExtEnvTempThresholdLow OBJECT-TYPE
SYNTAX Integer32
UNITS "degrees Celsius"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object indicates the minimum acceptable reading of the
testpoint in degrees Celsius.
"
::= { dEntityExtEnvTempEntry 5 }
dEntityExtEnvTempThresholdHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "degrees Celsius"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object indicates the maximum acceptable reading of the
testpoint in degrees Celsius.
"
::= { dEntityExtEnvTempEntry 6 }
dEntityExtEnvTempStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
abnormal(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object indicates the current temperature is over the thresholds or not.
'abnormal' indicates the temperature is over the thresholds.
'ok' indicates the temperature is not over the thresholds."
::= { dEntityExtEnvTempEntry 7 }
-- -----------------------------------------------------------------------------
dEntityExtEnvFanTable OBJECT-TYPE
SYNTAX SEQUENCE OF DEntityExtEnvFanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table is used to display the status of fans."
::= { dEntityExtEnvObjects 2 }
dEntityExtEnvFanEntry OBJECT-TYPE
SYNTAX DEntityExtEnvFanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry represents a fan status.
"
INDEX {
dEntityExtEnvFanUnitId,
dEntityExtEnvFanIndex
}
::= { dEntityExtEnvFanTable 1 }
DEntityExtEnvFanEntry ::= SEQUENCE {
dEntityExtEnvFanUnitId Unsigned32,
dEntityExtEnvFanIndex Integer32,
dEntityExtEnvFanDescr DisplayString,
dEntityExtEnvFanStatus INTEGER
}
dEntityExtEnvFanUnitId OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the unit (stacking device) or slot (chassis
device) ID at which the fan is located."
::= { dEntityExtEnvFanEntry 1 }
dEntityExtEnvFanIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is used to uniquely identify the fan
within a unit/slot.
This index is for SNMP purposes only, and has no intrinsic meaning."
::= { dEntityExtEnvFanEntry 2 }
dEntityExtEnvFanDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides human-sensible identification for the fan.
e.g. 'Left 1' for the first fan on the left.
"
::= { dEntityExtEnvFanEntry 3 }
dEntityExtEnvFanStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
fault(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the fan status."
::= { dEntityExtEnvFanEntry 4 }
-- -----------------------------------------------------------------------------
dEntityExtEnvPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF DEntityExtEnvPowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table is used to display the status of the power modules."
::= { dEntityExtEnvObjects 3 }
dEntityExtEnvPowerEntry OBJECT-TYPE
SYNTAX DEntityExtEnvPowerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry contains the information of a power module."
INDEX {
dEntityExtEnvPowerUnitId,
dEntityExtEnvPowerIndex
}
::= { dEntityExtEnvPowerTable 1 }
DEntityExtEnvPowerEntry ::= SEQUENCE {
dEntityExtEnvPowerUnitId Unsigned32,
dEntityExtEnvPowerIndex Unsigned32,
dEntityExtEnvPowerDescr DisplayString,
dEntityExtEnvPowerUsedPower Unsigned32,
dEntityExtEnvPowerMaxPower Unsigned32,
dEntityExtEnvPowerStatus INTEGER
}
dEntityExtEnvPowerUnitId OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the unit (stacking device) or slot (chassis
device) ID at which the power module is located."
::= { dEntityExtEnvPowerEntry 1 }
dEntityExtEnvPowerIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the ID of the power module.
This object is used to uniquely identify the power module.
This index is for SNMP purposes only, and has no intrinsic meaning.
"
::= { dEntityExtEnvPowerEntry 2 }
dEntityExtEnvPowerDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides human-sensible information for the power
module.
e.g. '#1 (internal)', '#2 (external)'.
"
::= { dEntityExtEnvPowerEntry 3 }
dEntityExtEnvPowerUsedPower OBJECT-TYPE
SYNTAX Unsigned32
UNITS "watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the amount of the power that has been allocated.
"
::= { dEntityExtEnvPowerEntry 4 }
dEntityExtEnvPowerMaxPower OBJECT-TYPE
SYNTAX Unsigned32
UNITS "watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates maximum power which the power module can supply.
"
::= { dEntityExtEnvPowerEntry 5 }
dEntityExtEnvPowerStatus OBJECT-TYPE
SYNTAX INTEGER {
inOperation(1),
failed(2),
empty(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the status of the power."
::= { dEntityExtEnvPowerEntry 6 }
-- -----------------------------------------------------------------------------
dEntityExtEnvAirFlowTable OBJECT-TYPE
SYNTAX SEQUENCE OF DEntityExtEnvAirFlowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table is used to display the status of the air flow function."
::= { dEntityExtEnvObjects 4 }
dEntityExtEnvAirFlowEntry OBJECT-TYPE
SYNTAX DEntityExtEnvAirFlowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry contains the information of the air flow function."
INDEX {
dEntityExtEnvAirFlowUnitId
}
::= { dEntityExtEnvAirFlowTable 1 }
DEntityExtEnvAirFlowEntry ::= SEQUENCE {
dEntityExtEnvAirFlowUnitId Unsigned32,
dEntityExtEnvAirFlowStatus INTEGER
}
dEntityExtEnvAirFlowUnitId OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the unit (stacking device) or slot (chassis
device) ID at which the air flow module is located."
::= { dEntityExtEnvAirFlowEntry 1 }
dEntityExtEnvAirFlowStatus OBJECT-TYPE
SYNTAX INTEGER
{ ok(1),
abnormal(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the status of the air flow.
The fans' air flow direction must match the system's air flow
direction to form an integrated air flow.
For example: In DXS-3600, the normal fans' air flow direction must
match the power fan's air flow direction.
The power fan blow the cold air from outside to inside, all the
normal fans must blow the hot air from inside to outside. Or the
power fan blow the hot air from inside to outside, all the normal
fans must blow the cold air from outside to inside.
If one or more fans' air flow direction does not match the system's
air flow direction, it will form an abnormal air flow. Then this log
message will be triggered.
ok(1) : A recover event indicates the air flow back to normal.
abnormal(2): An alarm event indicates the air flow detects abnormal.
"
::= { dEntityExtEnvAirFlowEntry 2 }
-- -----------------------------------------------------------------------------
dEntityExtEnvTrap OBJECT IDENTIFIER ::= { dEntityExtObjects 2 }
dEntityExtEnvNotifyEnable OBJECT-TYPE
SYNTAX BITS {
fan(0),
power(1),
temperature(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether a specified notification is enabled
or not. If a bit corresponding to a notification is set to 1, then
the specified notification can be generated.
fan(0) - fan trap state for warning fan event (fan failed or fan
recover).
power(1) - power trap state for warning power event (power failure
or power recovery).
temperature(2) - temperature trap state for warning temperature event
(temperature exceeds the thresholds or temperature recover).
"
::= { dEntityExtEnvTrap 1 }
-- -----------------------------------------------------------------------------
dEntityExtUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF DEntityExtUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table is used to display information of units."
::= { dEntityExtObjects 3 }
dEntityExtUnitEntry OBJECT-TYPE
SYNTAX DEntityExtUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry contains essential information of a unit."
INDEX { dEntityExtUnitIndex }
::= { dEntityExtUnitTable 1 }
DEntityExtUnitEntry ::= SEQUENCE {
dEntityExtUnitIndex Unsigned32,
dEntityExtUnitStatus INTEGER,
dEntityExtUnitUpTime Unsigned32
}
dEntityExtUnitIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the unit (stacking device) or slot (chassis
device) ID.
"
::= { dEntityExtUnitEntry 1 }
dEntityExtUnitStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
failed(2),
empty(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents the status of the unit:
ok(1) - This indicates the unit is okay.
failed(2) - This indicates the unit fails due to some reason.
empty(3) - This indicates that the unit is provisioned but
currently not installed.
"
::= { dEntityExtUnitEntry 2 }
dEntityExtUnitUpTime OBJECT-TYPE
SYNTAX Unsigned32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides the up time in units of seconds
for the unit since it was last re-initialized.
"
::= { dEntityExtUnitEntry 3 }
-- -----------------------------------------------------------------------------
dEntityExtMemoryUtilTable OBJECT-TYPE
SYNTAX SEQUENCE OF DEntityExtMemoryUtilEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table is used to display memory utilization information."
::= { dEntityExtObjects 4 }
dEntityExtMemoryUtilEntry OBJECT-TYPE
SYNTAX DEntityExtMemoryUtilEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry contains memory utilization information.
"
INDEX {
dEntityExtMemUtilUnitId,
dEntityExtMemUtilType
}
::= { dEntityExtMemoryUtilTable 1 }
DEntityExtMemoryUtilEntry ::= SEQUENCE {
dEntityExtMemUtilUnitId Integer32,
dEntityExtMemUtilType INTEGER,
dEntityExtMemUtilTotal Unsigned32,
dEntityExtMemUtilUsed Unsigned32,
dEntityExtMemUtilFree Unsigned32
}
dEntityExtMemUtilUnitId OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the unit (stacking device) or slot (chassis
device) ID.
"
::= { dEntityExtMemoryUtilEntry 1 }
dEntityExtMemUtilType OBJECT-TYPE
SYNTAX INTEGER {
dram(1),
flash(2),
nvram(3)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The object indicates the memory type of the entry."
::= { dEntityExtMemoryUtilEntry 2 }
dEntityExtMemUtilTotal OBJECT-TYPE
SYNTAX Unsigned32
UNITS "KB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the total memory size of the entry."
::= { dEntityExtMemoryUtilEntry 3 }
dEntityExtMemUtilUsed OBJECT-TYPE
SYNTAX Unsigned32
UNITS "KB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the used memory size of the entry."
::= { dEntityExtMemoryUtilEntry 4 }
dEntityExtMemUtilFree OBJECT-TYPE
SYNTAX Unsigned32
UNITS "KB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the free memory size of the entry."
::= { dEntityExtMemoryUtilEntry 5 }
-- -----------------------------------------------------------------------------
dEntityExtCpuUtilTable OBJECT-TYPE
SYNTAX SEQUENCE OF DEntityExtCpuUtilEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table is used to display CPU utilization information."
::= { dEntityExtObjects 7 }
dEntityExtCpuUtilEntry OBJECT-TYPE
SYNTAX DEntityExtCpuUtilEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry contains CPU information."
INDEX {
dEntityExtCpuUtilUnitId,
dEntityExtCpuUtilCpuID
}
::= { dEntityExtCpuUtilTable 1 }
DEntityExtCpuUtilEntry ::= SEQUENCE {
dEntityExtCpuUtilUnitId Unsigned32,
dEntityExtCpuUtilCpuID Unsigned32,
dEntityExtCpuUtilFiveSeconds Unsigned32,
dEntityExtCpuUtilOneMinute Unsigned32,
dEntityExtCpuUtilFiveMinutes Unsigned32
}
dEntityExtCpuUtilUnitId OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the unit (stacking device) or slot (chassis
device) ID.
"
::= { dEntityExtCpuUtilEntry 1 }
dEntityExtCpuUtilCpuID OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is used to uniquely identify the CPU within a unit
(multiprocessing system)."
::= { dEntityExtCpuUtilEntry 2 }
dEntityExtCpuUtilFiveSeconds OBJECT-TYPE
SYNTAX Unsigned32
UNITS "percentage"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This objects indicates the overall CPU busy percentage in the last
5 second period.
The value will be between 0% (idle) and 100% (very busy).
"
::= { dEntityExtCpuUtilEntry 3 }
dEntityExtCpuUtilOneMinute OBJECT-TYPE
SYNTAX Unsigned32
UNITS "percentage"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This objects indicates the overall CPU busy percentage in the last
1 minute period.
The value will be between 0% (idle) and 100% (very busy).
"
::= { dEntityExtCpuUtilEntry 4 }
dEntityExtCpuUtilFiveMinutes OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This objects indicates the overall CPU busy percentage in the last
5 minute period.
The value will be between 0% (idle) and 100% (very busy).
"
::= { dEntityExtCpuUtilEntry 5 }
-- -----------------------------------------------------------------------------
dEntityExtVersionTable OBJECT-TYPE
SYNTAX SEQUENCE OF DEntityExtVersionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table is used to display version information of units."
::= { dEntityExtObjects 8 }
dEntityExtVersionEntry OBJECT-TYPE
SYNTAX DEntityExtVersionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry contains version information of a unit."
INDEX { dEntityExtVersionUnitId}
::= { dEntityExtVersionTable 1 }
DEntityExtVersionEntry ::= SEQUENCE {
dEntityExtVersionUnitId Unsigned32,
dEntityExtVersionBootloader DisplayString,
dEntityExtVersionRuntime DisplayString
}
dEntityExtVersionUnitId OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the unit (stacking device) or slot (chassis
device) ID.
"
::= { dEntityExtVersionEntry 1 }
dEntityExtVersionBootloader OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the bootloader version of the unit. "
::= { dEntityExtVersionEntry 2 }
dEntityExtVersionRuntime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the firmware version of one unit. "
::= { dEntityExtVersionEntry 3 }
-- -----------------------------------------------------------------------------
-- Notifications
-- -----------------------------------------------------------------------------
dEntityExtFanStatusChg NOTIFICATION-TYPE
OBJECTS {
dEntityExtEnvFanUnitId,
dEntityExtEnvFanIndex,
dEntityExtEnvFanStatus
}
STATUS current
DESCRIPTION
"This trap indicates a fan fails (dEntityExtEnvFanStatus is 'fault') or
recovers (dEntityExtEnvFanStatus is 'ok'). "
::= { dEntityExtNotifications 1 }
dEntityExtThermalStatusChg NOTIFICATION-TYPE
OBJECTS {
dEntityExtEnvTempUnitId,
dEntityExtEnvTempIndex,
dEntityExtEnvTempStatus
}
STATUS current
DESCRIPTION
"This trap indicates a thermal alarms (dEntityExtEnvTempStatus
is 'abnormal') or recovers (dEntityExtEnvTempStatus is 'ok'). "
::= { dEntityExtNotifications 2 }
dEntityExtPowerStatusChg NOTIFICATION-TYPE
OBJECTS {
dEntityExtEnvPowerUnitId,
dEntityExtEnvPowerIndex,
dEntityExtEnvPowerStatus
}
STATUS current
DESCRIPTION
"This trap indicates a power module fails, recovers or is removed.
"
::= { dEntityExtNotifications 3 }
dEntityExtAirFlowChg NOTIFICATION-TYPE
OBJECTS {
dEntityExtEnvAirFlowUnitId,
dEntityExtEnvAirFlowStatus
}
STATUS current
DESCRIPTION
"This trap is triggered when the air flow status is changed from 'ok'
to 'abnormal' and vice versa. dEntityExtEnvAirFlowStatus indicates
the current (new) fan air flow state.
"
::= { dEntityExtNotifications 4 }
dEntityExtFactoryResetButton NOTIFICATION-TYPE
OBJECTS {
dEntityExtUnitIndex
}
STATUS current
DESCRIPTION
"This trap is triggered when the factory reset button was pressed.
"
::= { dEntityExtNotifications 5 }
-- -----------------------------------------------------------------------------
-- MIB Conformance statements
-- -----------------------------------------------------------------------------
dEntityExtMIBCompliances OBJECT IDENTIFIER ::= { dEntityExtConformance 1 }
dEntityExtMIBGroups OBJECT IDENTIFIER ::= { dEntityExtConformance 2 }
dEntityExtCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which implement the
DLINKSW-ENTITY-EXT-MIB."
MODULE -- this module
MANDATORY-GROUPS {
dEntityExtSystemInfoGroup
}
GROUP dEntityExtTempGroup
DESCRIPTION
"This group is mandatory if monitoring environment temperature
is supported."
OBJECT dEntityExtEnvTempThresholdLow
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT dEntityExtEnvTempThresholdHigh
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
GROUP dEntityExtThermalNotifGroup
DESCRIPTION
"This group is mandatory if monitoring environment temperature
is supported."
GROUP dEntityExtFanGroup
DESCRIPTION
"This group is mandatory if monitoring fan is supported."
GROUP dEntityExtFanNotifGroup
DESCRIPTION
"This group is mandatory if monitoring fan is supported."
GROUP dEntityExtPowerGroup
DESCRIPTION
"This group is mandatory if monitoring power is supported."
GROUP dEntityExtPowerNotifGroup
DESCRIPTION
"This group is mandatory if monitoring power is supported."
GROUP dEntityExtAirFlowNotifGroup
DESCRIPTION
"This group is mandatory if monitoring air flow is supported."
GROUP dEntityExtGenericNotifInfoGroup
DESCRIPTION
"This group is mandatory if one kind of notification is supported."
::= { dEntityExtMIBCompliances 1 }
-- Units of Conformance
dEntityExtTempGroup OBJECT-GROUP
OBJECTS {
dEntityExtEnvTempDescr,
dEntityExtEnvTempCurrent,
dEntityExtEnvTempThresholdLow,
dEntityExtEnvTempThresholdHigh,
dEntityExtEnvTempStatus
}
STATUS current
DESCRIPTION
"A collection of objects provides information of the system temperature."
::= { dEntityExtMIBGroups 1 }
dEntityExtFanGroup OBJECT-GROUP
OBJECTS {
dEntityExtEnvFanDescr,
dEntityExtEnvFanStatus
}
STATUS current
DESCRIPTION
"A collection of objects providing informations of fans."
::= { dEntityExtMIBGroups 2 }
dEntityExtPowerGroup OBJECT-GROUP
OBJECTS {
dEntityExtEnvPowerDescr,
dEntityExtEnvPowerUsedPower,
dEntityExtEnvPowerMaxPower,
dEntityExtEnvPowerStatus
}
STATUS current
DESCRIPTION
"A collection of objects providing information of power modules.
"
::= { dEntityExtMIBGroups 3 }
dEntityExtSystemInfoGroup OBJECT-GROUP
OBJECTS {
dEntityExtUnitStatus,
dEntityExtUnitUpTime,
dEntityExtMemUtilTotal,
dEntityExtMemUtilUsed,
dEntityExtMemUtilFree,
dEntityExtCpuUtilFiveSeconds,
dEntityExtCpuUtilOneMinute,
dEntityExtCpuUtilFiveMinutes,
dEntityExtVersionBootloader,
dEntityExtVersionRuntime
}
STATUS current
DESCRIPTION
"A collection of objects provides information of the system temperature."
::= { dEntityExtMIBGroups 4 }
dEntityExtGenericNotifInfoGroup OBJECT-GROUP
OBJECTS {
dEntityExtEnvNotifyEnable
}
STATUS current
DESCRIPTION
"A collection of objects provides generic information for binding variables
of notification.
"
::= { dEntityExtMIBGroups 5 }
dEntityExtFanNotifGroup NOTIFICATION-GROUP
NOTIFICATIONS { dEntityExtFanStatusChg }
STATUS current
DESCRIPTION
"A collection of notifications for indicating the status change of fans."
::= { dEntityExtMIBGroups 6 }
dEntityExtThermalNotifGroup NOTIFICATION-GROUP
NOTIFICATIONS { dEntityExtThermalStatusChg }
STATUS current
DESCRIPTION
"A collection of notifications for indicating the status change of thermals."
::= { dEntityExtMIBGroups 7 }
dEntityExtPowerNotifGroup NOTIFICATION-GROUP
NOTIFICATIONS { dEntityExtPowerStatusChg }
STATUS current
DESCRIPTION
"A collection of notifications for indicating the status change of power module."
::= { dEntityExtMIBGroups 8 }
dEntityExtAirFlowNotifGroup NOTIFICATION-GROUP
NOTIFICATIONS { dEntityExtAirFlowChg }
STATUS current
DESCRIPTION
"A collection of notifications for indicating the status change of the air flow."
::= { dEntityExtMIBGroups 9 }
dEntityExtFactoryResetButtonNotifGroup NOTIFICATION-GROUP
NOTIFICATIONS { dEntityExtFactoryResetButton }
STATUS current
DESCRIPTION
"A collection of notifications for indicating the factory reset button."
::= { dEntityExtMIBGroups 10 }
END