-- MGNT2.TXT: MIB
|
|
--
|
|
--MIB Part Number:3MI01002CABA
|
|
--MIB Version:01
|
|
--
|
|
-- Copyright (c) 2017 by Ekinops
|
|
-- All rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
|
|
EKINOPS-MGNT2-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
ekinops,
|
|
EkiState,
|
|
EkiOnOff,
|
|
EkiProtocol,
|
|
EkiApiState,
|
|
EkiLoadGWSW,
|
|
EkiLoadState,
|
|
EkiLoadPermutMethod,
|
|
EkiSynchroMode,
|
|
EkiLoadPermutMode
|
|
FROM EKINOPS-MIB
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
NOTIFICATION-TYPE,
|
|
Unsigned32,
|
|
Integer32,
|
|
IpAddress
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION,
|
|
DisplayString,
|
|
RowStatus
|
|
FROM SNMPv2-TC;
|
|
|
|
mgnt2 MODULE-IDENTITY
|
|
LAST-UPDATED "201701100000Z"
|
|
ORGANIZATION "Ekinops"
|
|
CONTACT-INFO
|
|
"Ekinops
|
|
|
|
3, rue Blaise Pascal
|
|
F-22300 Lannion / FRANCE
|
|
|
|
Tel : +33 (0)2 96 05 00 30
|
|
Fax : +33 (0)2 96 48 62 39
|
|
|
|
E-mail: support@ekinops.net"
|
|
DESCRIPTION
|
|
"MIB for Ekinops 360 management."
|
|
REVISION "200511240000Z"
|
|
DESCRIPTION
|
|
"Initial version."
|
|
REVISION "200601240000Z"
|
|
DESCRIPTION
|
|
"Add the ekicraft package table."
|
|
REVISION "200603100000Z"
|
|
DESCRIPTION
|
|
"Change Rack full to Rack Not Full"
|
|
REVISION "200605100000Z"
|
|
DESCRIPTION
|
|
"Gateways are managed by a table"
|
|
REVISION "200605230000Z"
|
|
DESCRIPTION
|
|
"Replace PBU by PM"
|
|
REVISION "200609280000Z"
|
|
DESCRIPTION
|
|
"CRAFT/LINUX Inventory Insertion"
|
|
REVISION "200612130000Z"
|
|
DESCRIPTION
|
|
"Plug-in inventory table insertion"
|
|
REVISION "200702090000Z"
|
|
DESCRIPTION
|
|
"Add Backpanel ,Fan inventory and error counters"
|
|
REVISION "200704240000Z"
|
|
DESCRIPTION
|
|
"Add detailed traps"
|
|
REVISION "200706190000Z"
|
|
DESCRIPTION
|
|
"Add ABS3 objects"
|
|
REVISION "200708270000Z"
|
|
DESCRIPTION
|
|
"Add Groups number in board table for pm1008dc"
|
|
REVISION "200711270000Z"
|
|
DESCRIPTION
|
|
"Update Ekinops Address,Helps on objects,Add Dcc management"
|
|
REVISION "200805200000Z"
|
|
DESCRIPTION
|
|
"Add syslog and ntp servers ip addresses"
|
|
REVISION "200806180000Z"
|
|
DESCRIPTION
|
|
"Add Inactivity Time out"
|
|
REVISION "200808180000Z"
|
|
DESCRIPTION
|
|
"Add Cli access, create a textual convention for DCC access.Add Craft Access"
|
|
REVISION "200810070000Z"
|
|
DESCRIPTION
|
|
"Invert code on DCC mode"
|
|
REVISION "200811190000Z"
|
|
DESCRIPTION
|
|
"Insert Chassis Ethernet Split"
|
|
REVISION "200901050000Z"
|
|
DESCRIPTION
|
|
"Insert Chassis Global Conf"
|
|
REVISION "200912150000Z"
|
|
DESCRIPTION
|
|
"Correction on traps"
|
|
REVISION "201001040000Z"
|
|
DESCRIPTION
|
|
"Insert CRIT/URG/NURG/Acknowledge"
|
|
REVISION "201002160000Z"
|
|
DESCRIPTION
|
|
"Add CondType and NMS parameters"
|
|
REVISION "201007160000Z"
|
|
DESCRIPTION
|
|
"Add perf management for the NMS"
|
|
REVISION "201010270000Z"
|
|
DESCRIPTION
|
|
"Add new filters for traps"
|
|
|
|
REVISION "201103170000Z"
|
|
DESCRIPTION
|
|
"Add new filters for traps"
|
|
REVISION "201104070000Z"
|
|
DESCRIPTION
|
|
"New mode on new ehternet input"
|
|
REVISION "201104130000Z"
|
|
DESCRIPTION
|
|
"Polling Manager fail insertion"
|
|
REVISION "201105270000Z"
|
|
DESCRIPTION
|
|
"Rajout AlarmType sur Extraction Fan"
|
|
REVISION "201106080000Z"
|
|
DESCRIPTION
|
|
"Rajout Cold Reset"
|
|
REVISION "201106300000Z"
|
|
DESCRIPTION
|
|
"PerfCapStatus new type"
|
|
REVISION "201109120000Z"
|
|
DESCRIPTION
|
|
"New data for Atom"
|
|
REVISION "201202080000Z"
|
|
DESCRIPTION
|
|
"PM labelling removal"
|
|
REVISION "201203190000Z"
|
|
DESCRIPTION
|
|
"Add mgnt2SubFunctionLabel for 100G"
|
|
REVISION "201207160000Z"
|
|
DESCRIPTION
|
|
"Minor cosmetic updates"
|
|
REVISION "201305280000Z"
|
|
DESCRIPTION
|
|
"RSTP configuration object"
|
|
REVISION "201305300000Z"
|
|
DESCRIPTION
|
|
"Dust filter insertion, CPU Temp warning"
|
|
REVISION "201308290000Z"
|
|
DESCRIPTION
|
|
"LLDP configuration object"
|
|
REVISION "201309040000Z"
|
|
DESCRIPTION
|
|
"MGNT Shutdown adding"
|
|
REVISION "201309110000Z"
|
|
DESCRIPTION
|
|
"Log file mode insertion"
|
|
REVISION "201311060000Z"
|
|
DESCRIPTION
|
|
"RADIUS objects"
|
|
REVISION "201407300000Z"
|
|
DESCRIPTION
|
|
"Node Controller objects"
|
|
REVISION "201409010000Z"
|
|
DESCRIPTION
|
|
"Probcause,AlarmType - NMS completion"
|
|
REVISION "201502110000Z"
|
|
DESCRIPTION
|
|
"HTTP configuration"
|
|
REVISION "201504010000Z"
|
|
DESCRIPTION
|
|
"Add bindings for Node Controller"
|
|
REVISION "201504140000Z"
|
|
DESCRIPTION
|
|
"RSTP Thresholds"
|
|
REVISION "201504140000Z"
|
|
DESCRIPTION
|
|
"Users privilege"
|
|
REVISION "201510090000Z"
|
|
DESCRIPTION
|
|
"Add in mgnt2SlotStatus"
|
|
REVISION "201511050000Z"
|
|
DESCRIPTION
|
|
"Appropriate Limits on SYNTAX of some OBJECT-TYPE "
|
|
REVISION "201605270000Z"
|
|
DESCRIPTION
|
|
"Add objects for fail login attemps"
|
|
REVISION "201606150000Z"
|
|
DESCRIPTION
|
|
"Removable Fan modules handling"
|
|
REVISION "201610120000Z"
|
|
DESCRIPTION
|
|
"Modification of numbering of the fans"
|
|
REVISION "201701100000Z"
|
|
DESCRIPTION
|
|
"FTP, TFTP enable disable"
|
|
::= { ekinops 7 }
|
|
|
|
--- *****************************************************
|
|
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
--- TEXTUAL-CONVENTION
|
|
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
--- *****************************************************
|
|
|
|
Mgnt2CliAccessValues ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "different type of access by ethernet for the CLI"
|
|
SYNTAX INTEGER {
|
|
noCliByEthernet(0),
|
|
cliBySSH(1),
|
|
cliByTelnet(2)
|
|
}
|
|
|
|
Mgnt2CraftAccessValues ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "enables access to the CRAFT"
|
|
SYNTAX INTEGER {
|
|
noCraftAccess(0),
|
|
craftEnable(1),
|
|
craftEnableHttps(2)
|
|
}
|
|
|
|
Mgnt2DccAccessValues ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "different modes for the Dcc access"
|
|
SYNTAX INTEGER {
|
|
mode1Slots2s4s6s8s10(0),
|
|
mode2Slots2s6s10s14s18(1)
|
|
}
|
|
|
|
Mgnt2TrapModeValues ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "different modes for the trap generation"
|
|
SYNTAX INTEGER {
|
|
syntheticTrap(0),
|
|
detailedTrap(1),
|
|
nmsTrap(2)
|
|
}
|
|
|
|
Mgnt2AckMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "different modes to acknowledge alarms"
|
|
SYNTAX INTEGER {
|
|
modeA(1),
|
|
modeB(2)
|
|
}
|
|
|
|
Mgnt2PerfResyncValues ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "different modes for the trap generation"
|
|
SYNTAX INTEGER {
|
|
perfResyncIdle(1),
|
|
perfResyncSync(2),
|
|
perfResyncReady(3),
|
|
perfResyncDelete(4)
|
|
}
|
|
|
|
Mgnt2NetMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "different modes for the network management"
|
|
SYNTAX INTEGER {
|
|
switch(1),
|
|
gateway(2)
|
|
}
|
|
|
|
Mgnt2MasterEthMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "different modes for the Master"
|
|
SYNTAX INTEGER {
|
|
static(1),
|
|
dhcp(2)
|
|
}
|
|
|
|
Mgnt2SubnetEthMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "different modes for the Subnet"
|
|
SYNTAX INTEGER {
|
|
static(1),
|
|
dhcp(2)
|
|
}
|
|
|
|
Mgnt2AuthTypeValues ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Various types of authentication processes"
|
|
SYNTAX INTEGER {
|
|
authLocal(0),
|
|
authRADIUS(1),
|
|
authLDAP(2)
|
|
}
|
|
|
|
Mgnt2LogFileMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "different modes for the log files"
|
|
SYNTAX INTEGER {
|
|
disabled (0),
|
|
linear(1),
|
|
rotary(2)
|
|
}
|
|
|
|
|
|
Mgnt2SlotStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Status of the slot"
|
|
SYNTAX INTEGER {
|
|
slotEmpty(0),
|
|
pmReady(1),
|
|
pmReset(2),
|
|
pmLoad(3),
|
|
pmPassive(4),
|
|
pmUnknown(5),
|
|
pmNotReady(6)
|
|
}
|
|
|
|
|
|
|
|
|
|
|
|
-- *****************************************************************
|
|
--
|
|
-- MGNT2 MIB root mapping
|
|
--
|
|
-- *****************************************************************
|
|
mgnt2SNMPAgentData OBJECT IDENTIFIER ::= { mgnt2 1 }
|
|
mgnt2Hardware OBJECT IDENTIFIER ::= { mgnt2 2}
|
|
mgnt2Traps OBJECT IDENTIFIER ::= { mgnt2 3}
|
|
mgnt2SoftwareManagement OBJECT IDENTIFIER ::= { mgnt2 4}
|
|
mgnt2ConfigManagement OBJECT IDENTIFIER ::= { mgnt2 5}
|
|
mgnt2RemoteInventory OBJECT IDENTIFIER ::= { mgnt2 6}
|
|
mgnt2ErrorCounters OBJECT IDENTIFIER ::= { mgnt2 7}
|
|
mgnt2Perf OBJECT IDENTIFIER ::= { mgnt2 8}
|
|
|
|
-- *****************************************************************
|
|
--
|
|
-- MGNT2 SNMP Agent informations
|
|
--
|
|
-- *****************************************************************
|
|
|
|
mgnt2IPmanagment OBJECT IDENTIFIER ::= { mgnt2SNMPAgentData 1 }
|
|
|
|
|
|
mgnt2GigmManagerIpAddressTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2GigmManagerIpAddressEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manager IP address Table."
|
|
::= { mgnt2IPmanagment 1 }
|
|
|
|
mgnt2GigmManagerIpAddressEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2GigmManagerIpAddressEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { mgnt2GigmManagerIpIndex }
|
|
::= { mgnt2GigmManagerIpAddressTable 1 }
|
|
|
|
Mgnt2GigmManagerIpAddressEntry ::= SEQUENCE {
|
|
mgnt2GigmManagerIpIndex Integer32,
|
|
mgnt2GigmManagerIpAddress IpAddress,
|
|
mgnt2GigmManagerIpAddressTableRowStatus RowStatus,
|
|
mgnt2GigmManagerTrapPort Integer32,
|
|
mgnt2GigmManagerEnableCtrl EkiOnOff,
|
|
mgnt2GigmManagerEnableConfig EkiOnOff,
|
|
mgnt2GigmManagerEnableEvent EkiOnOff,
|
|
mgnt2GigmManagerEnableAlarmCrit EkiOnOff,
|
|
mgnt2GigmManagerEnableAlarmMajor EkiOnOff,
|
|
mgnt2GigmManagerEnableAlarmMinor EkiOnOff,
|
|
mgnt2GigmManagerRegistrationTimeout Integer32,
|
|
mgnt2GigmManagerEnableAlarmWarning EkiOnOff,
|
|
mgnt2GigmManagerEnableAlarmIndeterminate EkiOnOff
|
|
}
|
|
|
|
mgnt2GigmManagerIpIndex OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of the IP address of the manager"
|
|
::= { mgnt2GigmManagerIpAddressEntry 1 }
|
|
|
|
mgnt2GigmManagerIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of the manager:This OID defines the IP
|
|
address of the SNMP Manager attached to the Mgnt2"
|
|
::= { mgnt2GigmManagerIpAddressEntry 2 }
|
|
|
|
mgnt2GigmManagerIpAddressTableRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this row."
|
|
::= { mgnt2GigmManagerIpAddressEntry 3 }
|
|
|
|
mgnt2GigmManagerTrapPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manager UDP port."
|
|
::= { mgnt2GigmManagerIpAddressEntry 4 }
|
|
|
|
mgnt2GigmManagerEnableCtrl OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling trap of Ctrl."
|
|
::= { mgnt2GigmManagerIpAddressEntry 5 }
|
|
|
|
mgnt2GigmManagerEnableConfig OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling trap of config."
|
|
::= { mgnt2GigmManagerIpAddressEntry 6 }
|
|
|
|
mgnt2GigmManagerEnableEvent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling trap of event."
|
|
::= { mgnt2GigmManagerIpAddressEntry 7 }
|
|
|
|
mgnt2GigmManagerEnableAlarmCrit OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling trap of crit alarm."
|
|
::= { mgnt2GigmManagerIpAddressEntry 8 }
|
|
|
|
mgnt2GigmManagerEnableAlarmMajor OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling trap of major alarm."
|
|
::= { mgnt2GigmManagerIpAddressEntry 9 }
|
|
|
|
mgnt2GigmManagerEnableAlarmMinor OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling trap of minor alarm."
|
|
::= { mgnt2GigmManagerIpAddressEntry 10 }
|
|
|
|
|
|
mgnt2GigmManagerRegistrationTimeout OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time-out for manager activities."
|
|
::= { mgnt2GigmManagerIpAddressEntry 11 }
|
|
|
|
mgnt2GigmManagerEnableAlarmWarning OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling trap of warning alarm."
|
|
::= { mgnt2GigmManagerIpAddressEntry 12 }
|
|
|
|
mgnt2GigmManagerEnableAlarmIndeterminate OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling trap of indeterminate alarm."
|
|
::= { mgnt2GigmManagerIpAddressEntry 13 }
|
|
|
|
|
|
mgnt2GigmBoardIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of the Chassis:This OID defines the IP
|
|
address of the Mgnt2"
|
|
::= { mgnt2IPmanagment 2 }
|
|
|
|
mgnt2GigmIPAddresByDHCP OBJECT-TYPE
|
|
SYNTAX EkiState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address retrieved by DHCP:If enabled, the IP
|
|
address is retrieved by DHCP, in which case changes
|
|
take effect after a board reset. If disabled the
|
|
object, mgnt2GigmBoardIpAddress defines the address"
|
|
::= { mgnt2IPmanagment 3 }
|
|
|
|
|
|
mgnt2GigmNetmask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Netmask for the board IP address:This OID defined
|
|
the IP Subnet mask of the Mgnt2"
|
|
::= { mgnt2IPmanagment 4 }
|
|
|
|
mgnt2GigmGatewayAddressTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2GigmGatewayAddressEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway IP address Table: This table contains all
|
|
the gateway IP addresses."
|
|
::= { mgnt2IPmanagment 5 }
|
|
|
|
mgnt2GigmGatewayAddressEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2GigmGatewayAddressEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { mgnt2GigmGatewayIndex }
|
|
::= { mgnt2GigmGatewayAddressTable 1 }
|
|
|
|
Mgnt2GigmGatewayAddressEntry ::= SEQUENCE {
|
|
mgnt2GigmGatewayIndex Integer32,
|
|
mgnt2GigmGatewayAddress IpAddress,
|
|
mgnt2GigmGatewayOrder Integer32
|
|
}
|
|
|
|
mgnt2GigmGatewayIndex OBJECT-TYPE
|
|
SYNTAX Integer32(0..1)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of the IP address of the gateway"
|
|
::= { mgnt2GigmGatewayAddressEntry 1 }
|
|
|
|
mgnt2GigmGatewayAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of the gateway :This OID defines the IP
|
|
address of the gateway attached to the Chassis"
|
|
::= { mgnt2GigmGatewayAddressEntry 2 }
|
|
|
|
mgnt2GigmGatewayOrder OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway priority: This OID defines the priority of
|
|
the gateway (lower number for higher priority)"
|
|
::= { mgnt2GigmGatewayAddressEntry 3 }
|
|
|
|
mgnt2GigmSyslog OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of the syslog server:This OID defines
|
|
the IP address of the syslog of the Mgnt2"
|
|
::= { mgnt2IPmanagment 6 }
|
|
|
|
mgnt2GigmNtpServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of the ntp server:This OID defines
|
|
the IP address of the ntp server for the Mgnt2"
|
|
::= { mgnt2IPmanagment 7 }
|
|
|
|
|
|
mgnt2GigmNodeIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Node IP address :This OID defines
|
|
the Node IP address in node controller mode for the Mgnt2"
|
|
::= { mgnt2IPmanagment 8 }
|
|
|
|
|
|
mgnt2ModulesManagement OBJECT IDENTIFIER ::= { mgnt2SNMPAgentData 2 }
|
|
|
|
mgnt2GigmBoardTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2GigmBoardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of PMs plugged in the Chassis"
|
|
::= { mgnt2ModulesManagement 1 }
|
|
|
|
mgnt2GigmBoardEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2GigmBoardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row Definition for the PMs table"
|
|
INDEX { mgnt2IndexBoards }
|
|
::= { mgnt2GigmBoardTable 1 }
|
|
|
|
|
|
|
|
Mgnt2GigmBoardEntry ::=
|
|
SEQUENCE {
|
|
mgnt2IndexBoards
|
|
Integer32,
|
|
mgnt2Position
|
|
Integer32,
|
|
mgnt2Name
|
|
DisplayString,
|
|
mgnt2PortNumber
|
|
Integer32,
|
|
mgnt2LineNumber
|
|
Integer32,
|
|
mgnt2GroupNumber
|
|
Integer32,
|
|
mgnt2RootOIDInventory
|
|
OBJECT IDENTIFIER,
|
|
mgnt2SlotOcc
|
|
DisplayString,
|
|
mgnt2SubFunctionLabel
|
|
DisplayString,
|
|
mgnt2SlotStatus
|
|
Mgnt2SlotStatus
|
|
}
|
|
|
|
|
|
mgnt2IndexBoards OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index for PMs table"
|
|
::= { mgnt2GigmBoardEntry 1 }
|
|
|
|
mgnt2Position OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PM Slot number:This OID gives the slot number in
|
|
which the PM is plugged"
|
|
::= { mgnt2GigmBoardEntry 2 }
|
|
|
|
mgnt2Name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PM name:This OID gives the name of the PM plugged
|
|
in the Mgnt2"
|
|
::= { mgnt2GigmBoardEntry 3 }
|
|
|
|
mgnt2PortNumber OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Client Ports:This OID gives the number of
|
|
client ports on the PM plugged in the Mgnt2"
|
|
::= { mgnt2GigmBoardEntry 4 }
|
|
|
|
mgnt2LineNumber OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Line Ports:This OID gives the number of line
|
|
ports on the PM plugged in the Mgnt2"
|
|
::= { mgnt2GigmBoardEntry 5 }
|
|
|
|
mgnt2GroupNumber OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Groups:This OID gives the number of group
|
|
of clients on the PM plugged in the Mgnt2"
|
|
::= { mgnt2GigmBoardEntry 6 }
|
|
|
|
mgnt2RootOIDInventory OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"root oid of the inventory leaf of the corresponding PM"
|
|
::= { mgnt2GigmBoardEntry 7 }
|
|
|
|
mgnt2SlotOcc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PM Slot occupied:This OID gives the slots taken
|
|
by this PM"
|
|
::= { mgnt2GigmBoardEntry 8 }
|
|
|
|
|
|
mgnt2SubFunctionLabel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub Function Label: This OID gives the name of the sub
|
|
function embedded on the Chassis. (applied only on the
|
|
100G Chassis)"
|
|
::= { mgnt2GigmBoardEntry 9 }
|
|
|
|
|
|
|
|
mgnt2SlotStatus OBJECT-TYPE
|
|
SYNTAX Mgnt2SlotStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot Status: This OID gives the status of the slot
|
|
in the Chassis: See Textual COnvention"
|
|
::= { mgnt2GigmBoardEntry 10 }
|
|
|
|
|
|
|
|
mgnt2GigmSelectedBoard OBJECT-TYPE
|
|
SYNTAX INTEGER(1..256)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PM Slot number selected:PM selected for further
|
|
operations in the Ekinops module board tree. This
|
|
number is the slot number."
|
|
::= { mgnt2ModulesManagement 7 }
|
|
|
|
|
|
|
|
|
|
mgnt2GigmMibsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2GigmMibsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"List of MIBs supported by the Chassis SNMPAgent"
|
|
::= { mgnt2SNMPAgentData 4 }
|
|
|
|
mgnt2GigmMibsEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2GigmMibsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Row definition for MIBs table"
|
|
INDEX { mgnt2IndexMibs }
|
|
::= { mgnt2GigmMibsTable 1 }
|
|
|
|
|
|
|
|
Mgnt2GigmMibsEntry ::=
|
|
SEQUENCE {
|
|
mgnt2IndexMibs
|
|
Integer32,
|
|
mgnt2MibName
|
|
DisplayString,
|
|
mgnt2MibPartNumber
|
|
DisplayString
|
|
}
|
|
|
|
|
|
mgnt2IndexMibs OBJECT-TYPE
|
|
SYNTAX Integer32(1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Index for MIBs table"
|
|
::= { mgnt2GigmMibsEntry 1 }
|
|
|
|
mgnt2MibName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"MIB name:This OID gives the name of the MIBs
|
|
supported by the SNMP Agent"
|
|
::= { mgnt2GigmMibsEntry 2 }
|
|
|
|
mgnt2MibPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"MIB Part Number:This OID gives the part number of the MIBs
|
|
supported by the SNMP Agent"
|
|
::= { mgnt2GigmMibsEntry 3 }
|
|
|
|
mgnt2GigmLogicalName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mgnt2 name:This OID defines the name of the Mgnt2"
|
|
::= { mgnt2SNMPAgentData 5 }
|
|
|
|
mgnt2GigmEqptType OBJECT-TYPE
|
|
SYNTAX Integer32(1..128)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Equipment type:This OID defines the type of the Equipment"
|
|
::= { mgnt2SNMPAgentData 6 }
|
|
|
|
mgnt2GigmTrapCount OBJECT IDENTIFIER ::= { mgnt2SNMPAgentData 7 }
|
|
|
|
mgnt2GigmTrapCounter OBJECT-TYPE
|
|
SYNTAX Integer32(1..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap counter:This OID counts the number of trap sent"
|
|
::= { mgnt2GigmTrapCount 1 }
|
|
|
|
mgnt2GigmResetTrapCounter OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reset trap counter:This OID reset the trap counter to 0"
|
|
::= { mgnt2GigmTrapCount 2 }
|
|
|
|
|
|
mgnt2GigmSecurity OBJECT IDENTIFIER ::= { mgnt2SNMPAgentData 8 }
|
|
|
|
mgnt2GigmRoCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNMP Get community:This OID defines the community for the
|
|
SNMP Get function"
|
|
::= { mgnt2GigmSecurity 1 }
|
|
|
|
mgnt2GigmRwCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNMP Set community:This OID defines the community for the
|
|
SNMP Set function"
|
|
::= { mgnt2GigmSecurity 2 }
|
|
|
|
|
|
mgnt2GigmTrapCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNMP Trap community:This OID defines the community for the
|
|
SNMP Trap function"
|
|
::= { mgnt2GigmSecurity 3 }
|
|
|
|
|
|
mgnt2GigmTime OBJECT IDENTIFIER ::= { mgnt2SNMPAgentData 9 }
|
|
|
|
mgnt2GigmCurrentHour OBJECT-TYPE
|
|
SYNTAX INTEGER(0..23)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Hour time:This OID defines the hour of the chassis' time"
|
|
::= { mgnt2GigmTime 1 }
|
|
|
|
mgnt2GigmCurrentMinute OBJECT-TYPE
|
|
SYNTAX INTEGER(0..59)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Minute time:This OID defines the minute of the chassis' time"
|
|
::= { mgnt2GigmTime 2 }
|
|
|
|
mgnt2GigmCurrentYear OBJECT-TYPE
|
|
SYNTAX INTEGER(1970..3000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis year date:This OID defines the year of the chassis' date"
|
|
::= { mgnt2GigmTime 3 }
|
|
|
|
mgnt2GigmCurrentMonth OBJECT-TYPE
|
|
SYNTAX INTEGER(1..12)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis month date:This OID defines the month of the chassis' date"
|
|
::= { mgnt2GigmTime 4 }
|
|
|
|
mgnt2GigmCurrentDay OBJECT-TYPE
|
|
SYNTAX INTEGER(1..31)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis day date:This OID defines the day of the chassis' date"
|
|
::= { mgnt2GigmTime 5 }
|
|
|
|
|
|
|
|
mgnt2Authentication OBJECT IDENTIFIER ::= { mgnt2SNMPAgentData 10 }
|
|
|
|
mgnt2GigmRadiusServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of the RADIUS server:This OID defines
|
|
the IP address of the external RADIUS server for authentication"
|
|
::= { mgnt2Authentication 1 }
|
|
|
|
mgnt2GigmRadiusPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCP port number of the RADIUS server:This OID defines
|
|
the TCP port number of the external RADIUS server for
|
|
authentication"
|
|
::= { mgnt2Authentication 2 }
|
|
|
|
mgnt2GigmRadiusSecret OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shared secret of the RADIUS server:This OID defines
|
|
the shared secret password of the RADIUS server for
|
|
authentication"
|
|
::= { mgnt2Authentication 3 }
|
|
|
|
|
|
mgnt2GigmLdapHost OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"IP address of the LDAP host:This OID defines
|
|
the IP address of the external LDAP server for authentication"
|
|
::= { mgnt2Authentication 4 }
|
|
|
|
mgnt2GigmLdapPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"TCP port number of the LDAP server:This OID defines
|
|
the TCP port number of the external LDAP server for
|
|
authentication"
|
|
::= { mgnt2Authentication 5 }
|
|
|
|
|
|
mgnt2GigmLdapBase OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"LDAP base:This OID defines the name of the search
|
|
base of the LDAP server for
|
|
authentication<Help>LDAP base name spelled as follows:
|
|
'ou=users,ou=network,dc=yourcompany,dc=net'"
|
|
::= { mgnt2Authentication 6 }
|
|
|
|
mgnt2GigmLdapVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Protocol number in use by the LDAP server:This OID defines
|
|
the protocol version used by the external LDAP server for
|
|
authentication<Help>Protocol version used by the external LDAP
|
|
server for authentication"
|
|
::= { mgnt2Authentication 7 }
|
|
|
|
mgnt2GigmLdapBindDn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"LDAP Bind DN:This OID defines the login name used to connect
|
|
into the LDAP server base for
|
|
authentication<Help>LDAP binddn spelled as follows:
|
|
'cn=ldap_admin,dc=yourcompany,dc=net'"
|
|
::= { mgnt2Authentication 8 }
|
|
|
|
mgnt2GigmLdapBindPw OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Credentials to bind the LDAP server with:This OID defines
|
|
the credentials to bind the LDAP server with for
|
|
authentication<Help>Credentials for LDAP access (bindpw)"
|
|
::= { mgnt2Authentication 9 }
|
|
|
|
|
|
mgnt2GigmLdapScope OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Scope for LDAP base search:This OID defines
|
|
the search scope for an LDAP base search
|
|
<Help>LDAP search scope"
|
|
::= { mgnt2Authentication 10 }
|
|
|
|
mgnt2GigmLdapPamPasswd OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PAM password handling:This OID defines
|
|
the way the PAM password is handled for LDAP authentication
|
|
<Help>The 'pam_password' option sould be one of the following:
|
|
'clear', 'crypt', 'md5', 'racf', 'exop'"
|
|
::= { mgnt2Authentication 11 }
|
|
|
|
mgnt2GigmAuthenticationType OBJECT-TYPE
|
|
SYNTAX Mgnt2AuthTypeValues
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Authentication type in use"
|
|
::= { mgnt2Authentication 12 }
|
|
|
|
|
|
-- *****************************************************************
|
|
--
|
|
-- MGNT2 Software Management tables
|
|
--
|
|
-- *****************************************************************
|
|
|
|
mgnt2DwlUploadingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2DwlUploadingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"SNMP Agent SW packages in ram: List of the SNMP
|
|
agent software packages available in /ram for
|
|
download on the Chassis managment module flash"
|
|
::= { mgnt2SoftwareManagement 1 }
|
|
|
|
mgnt2DwlUploadingEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2DwlUploadingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Row definition for the package uploading table"
|
|
INDEX { mgnt2IndexUpload }
|
|
::= { mgnt2DwlUploadingTable 1 }
|
|
|
|
Mgnt2DwlUploadingEntry::=
|
|
SEQUENCE {
|
|
mgnt2IndexUpload
|
|
Integer32,
|
|
mgnt2DwlUploadFileName
|
|
DisplayString,
|
|
mgnt2ImmediateReplacement
|
|
EkiState,
|
|
mgnt2FileUpload
|
|
EkiOnOff,
|
|
mgnt2DeletePackageFromRam
|
|
EkiOnOff,
|
|
mgnt2FlashingInProgress
|
|
EkiOnOff
|
|
}
|
|
|
|
mgnt2IndexUpload OBJECT-TYPE
|
|
SYNTAX Integer32(0..4)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Index for uploading table"
|
|
::= { mgnt2DwlUploadingEntry 1 }
|
|
|
|
mgnt2DwlUploadFileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Package filename in RAM:This OID gives the name of
|
|
the SNMP agent software packages in RAM"
|
|
::= { mgnt2DwlUploadingEntry 2 }
|
|
|
|
mgnt2ImmediateReplacement OBJECT-TYPE
|
|
SYNTAX EkiState
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Immediat Agent Replacement:This OID indicates to
|
|
switch to selected SNMP agent immediately or after
|
|
reset of the MGNT2"
|
|
::= { mgnt2DwlUploadingEntry 3 }
|
|
|
|
mgnt2FileUpload OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Agent File Upload:This OID validates the upload of
|
|
the SNMP agent from RAM to FLASH"
|
|
::= { mgnt2DwlUploadingEntry 4 }
|
|
|
|
mgnt2DeletePackageFromRam OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Delete Package from RAM:This OID requests to delete
|
|
the SNMP Agent SW package from RAM"
|
|
::= { mgnt2DwlUploadingEntry 5 }
|
|
|
|
mgnt2FlashingInProgress OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Flashing in Progress:This OID indicates whether there
|
|
is a file upload to FLASH in progress"
|
|
::= { mgnt2DwlUploadingEntry 6 }
|
|
|
|
|
|
|
|
mgnt2DwlPackageTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2DwlPackageEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"List of SNMP agent software packages
|
|
present in flash memory"
|
|
::= { mgnt2SoftwareManagement 2 }
|
|
|
|
mgnt2DwlPackageEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2DwlPackageEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Row definition for the package management table"
|
|
INDEX { mgnt2IndexPackage }
|
|
::= { mgnt2DwlPackageTable 1 }
|
|
|
|
Mgnt2DwlPackageEntry::=
|
|
SEQUENCE {
|
|
mgnt2IndexPackage
|
|
Integer32,
|
|
mgnt2DwlPackageFileName
|
|
DisplayString,
|
|
mgnt2ExtractedPack
|
|
EkiOnOff,
|
|
mgnt2SwitchTo
|
|
EkiOnOff,
|
|
mgnt2Immediate
|
|
EkiOnOff,
|
|
mgnt2DeletePackageFromFlash
|
|
EkiOnOff,
|
|
mgnt2PackageExtractionInProgress
|
|
EkiOnOff
|
|
}
|
|
|
|
mgnt2IndexPackage OBJECT-TYPE
|
|
SYNTAX Integer32(0..4)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Index for package management table"
|
|
::= { mgnt2DwlPackageEntry 1 }
|
|
|
|
mgnt2DwlPackageFileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Package File name in FLASH:This OID gives the name
|
|
of the SNMP agent software package in FLASH"
|
|
::= { mgnt2DwlPackageEntry 2 }
|
|
|
|
mgnt2ExtractedPack OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Extracted SNMP agent software pack.: Indicates
|
|
whether the package is currently extracted in the FLASH.
|
|
If it is, it must not be deleted"
|
|
::= { mgnt2DwlPackageEntry 3 }
|
|
|
|
mgnt2SwitchTo OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Switch to package:This OID activates the SNMP Agent
|
|
Software package"
|
|
::= { mgnt2DwlPackageEntry 4 }
|
|
|
|
mgnt2Immediate OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Immediate SNMP agent activation: This OID indicates
|
|
whether the package is scheduled for immediate
|
|
activation or activation will take place following the
|
|
next reset"
|
|
::= { mgnt2DwlPackageEntry 5 }
|
|
|
|
mgnt2DeletePackageFromFlash OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Delete package from FLASH:This OID deletes the SNMP
|
|
agent software package from the FLASH"
|
|
::= { mgnt2DwlPackageEntry 6 }
|
|
|
|
mgnt2PackageExtractionInProgress OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Package extraction in progress:This OID indicates that
|
|
a SNMP agent software activation is in progress"
|
|
::= { mgnt2DwlPackageEntry 7 }
|
|
|
|
mgnt2DwlUploadingTableUpdate OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Uploading Table update:This OID updates the contents of
|
|
the uploading table"
|
|
::= { mgnt2SoftwareManagement 3 }
|
|
|
|
|
|
|
|
|
|
mgnt2LoadPMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2LoadPMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"List of the PM module software files (GW/SW)
|
|
present on the repository"
|
|
::= { mgnt2SoftwareManagement 4 }
|
|
|
|
|
|
mgnt2LoadPMEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2LoadPMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Row definition for the LOAD article table"
|
|
INDEX { mgnt2LoadPMIndex }
|
|
::= { mgnt2LoadPMTable 1 }
|
|
|
|
Mgnt2LoadPMEntry::=
|
|
SEQUENCE {
|
|
mgnt2LoadPMIndex
|
|
Integer32,
|
|
mgnt2LoadFileName
|
|
DisplayString,
|
|
mgnt2LoadFileType
|
|
EkiLoadGWSW,
|
|
mgnt2LoadState
|
|
EkiLoadState,
|
|
mgnt2LoadModuleNumber
|
|
Integer32,
|
|
mgnt2LoadResetMethod
|
|
EkiLoadPermutMethod,
|
|
mgnt2LoadResetMode
|
|
EkiLoadPermutMode,
|
|
mgnt2LoadBankNumber
|
|
Integer32,
|
|
mgnt2LoadDownloadProgress
|
|
Integer32,
|
|
mgnt2LoadTransfer
|
|
EkiOnOff,
|
|
mgnt2LoadDelete
|
|
EkiOnOff
|
|
}
|
|
|
|
mgnt2LoadPMIndex OBJECT-TYPE
|
|
SYNTAX Integer32(0..32)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Index for Load article table"
|
|
::= { mgnt2LoadPMEntry 1 }
|
|
|
|
mgnt2LoadFileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM Upgrade filename:This OID gives the name of
|
|
the file"
|
|
::= { mgnt2LoadPMEntry 2 }
|
|
|
|
mgnt2LoadFileType OBJECT-TYPE
|
|
SYNTAX EkiLoadGWSW
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM upgrade file type:This OID gives the type of
|
|
file (gateware or software)"
|
|
::= { mgnt2LoadPMEntry 3 }
|
|
|
|
mgnt2LoadState OBJECT-TYPE
|
|
SYNTAX EkiLoadState
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM upgrade status:This OID gives the status of the
|
|
selected Load file"
|
|
::= { mgnt2LoadPMEntry 4 }
|
|
|
|
mgnt2LoadModuleNumber OBJECT-TYPE
|
|
SYNTAX Integer32(1..8)
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM ugprade target:This OID defines the slot number
|
|
of the PM to upgrade"
|
|
::= { mgnt2LoadPMEntry 5 }
|
|
|
|
mgnt2LoadResetMethod OBJECT-TYPE
|
|
SYNTAX EkiLoadPermutMethod
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM upgrade reset method:This OID defines the reset
|
|
method (manual, immediate or scheduled)"
|
|
::= { mgnt2LoadPMEntry 6 }
|
|
|
|
mgnt2LoadResetMode OBJECT-TYPE
|
|
SYNTAX EkiLoadPermutMode
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM upgrade reset mode:This OID defines the type of
|
|
reset (cold or warm)"
|
|
::= { mgnt2LoadPMEntry 7 }
|
|
|
|
mgnt2LoadBankNumber OBJECT-TYPE
|
|
SYNTAX Integer32(0..4)
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM upgrade bank number:This OID defines the target
|
|
bank number in the PM's flash"
|
|
::= { mgnt2LoadPMEntry 8 }
|
|
|
|
mgnt2LoadDownloadProgress OBJECT-TYPE
|
|
SYNTAX Integer32(0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM upgrade progress:This OID gives the upgrade
|
|
progress (percentage)"
|
|
::= { mgnt2LoadPMEntry 9 }
|
|
|
|
mgnt2LoadTransfer OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM upgrade transfer:This OID launchs the transfer
|
|
of the associated file to the selected PM's flash"
|
|
::= { mgnt2LoadPMEntry 10 }
|
|
|
|
mgnt2LoadDelete OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM upgrade delete file:This OID deletes the
|
|
associated file from the RAM of the management board"
|
|
::= { mgnt2LoadPMEntry 11 }
|
|
|
|
|
|
mgnt2LoadPMTableUpdate OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Load PM Table update:This OID updates the contents
|
|
of the Load table"
|
|
::= { mgnt2SoftwareManagement 5 }
|
|
|
|
|
|
|
|
mgnt2DwlEkicraftPkgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2DwlEkicraftPkgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"List of Ekicraft software packages
|
|
present in flash memory"
|
|
::= { mgnt2SoftwareManagement 6 }
|
|
|
|
mgnt2DwlEkicraftPkgEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2DwlEkicraftPkgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Row definition for the package management table"
|
|
INDEX { mgnt2IndexEkicraftPkg }
|
|
::= { mgnt2DwlEkicraftPkgTable 1 }
|
|
|
|
Mgnt2DwlEkicraftPkgEntry::=
|
|
SEQUENCE {
|
|
mgnt2IndexEkicraftPkg
|
|
Integer32,
|
|
mgnt2DwlEkicraftPkgFileName
|
|
DisplayString,
|
|
mgnt2DwlEkicraftExtractedPack
|
|
EkiOnOff,
|
|
mgnt2DwlEkicraftSwitchTo
|
|
EkiOnOff,
|
|
mgnt2DwlEkicraftImmediate
|
|
EkiOnOff,
|
|
mgnt2DeleteEkicraftPkgFromFlash
|
|
EkiOnOff,
|
|
mgnt2EkicraftPkgExtractionInProgress
|
|
EkiOnOff
|
|
}
|
|
|
|
mgnt2IndexEkicraftPkg OBJECT-TYPE
|
|
SYNTAX Integer32(0..4)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Index for Ekicraft package management table"
|
|
::= { mgnt2DwlEkicraftPkgEntry 1 }
|
|
|
|
mgnt2DwlEkicraftPkgFileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Package File name in FLASH:This OID gives the name
|
|
of the Ekicraft software package in FLASH"
|
|
::= { mgnt2DwlEkicraftPkgEntry 2 }
|
|
|
|
mgnt2DwlEkicraftExtractedPack OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Extracted Ekicraft software pack.: Indicates
|
|
whether the package is currently extracted in the FLASH.
|
|
If it is, it must not be deleted"
|
|
::= { mgnt2DwlEkicraftPkgEntry 3 }
|
|
|
|
mgnt2DwlEkicraftSwitchTo OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Switch to package:This OID activates the Ekicraft
|
|
Software package"
|
|
::= { mgnt2DwlEkicraftPkgEntry 4 }
|
|
|
|
mgnt2DwlEkicraftImmediate OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Immediate Ekicraft activation: This OID indicates
|
|
whether the package is scheduled for immediate
|
|
activation or activation will take place following the
|
|
next reset"
|
|
::= { mgnt2DwlEkicraftPkgEntry 5 }
|
|
|
|
mgnt2DeleteEkicraftPkgFromFlash OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Delete package from FLASH:This OID deletes the Ekicraft
|
|
software package from the FLASH"
|
|
::= { mgnt2DwlEkicraftPkgEntry 6 }
|
|
|
|
mgnt2EkicraftPkgExtractionInProgress OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Package extraction in progress:This OID indicates that
|
|
an Ekicraft activation is in progress"
|
|
::= { mgnt2DwlEkicraftPkgEntry 7 }
|
|
|
|
|
|
-- *****************************************************************
|
|
--
|
|
-- Config management tables
|
|
--
|
|
-- *****************************************************************
|
|
|
|
mgnt2CnfUploadConfigFilesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2CnfUploadConfigFilesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"List of configuration files uploaded to RAM"
|
|
::= { mgnt2ConfigManagement 1 }
|
|
|
|
mgnt2CnfUploadConfigFilesEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2CnfUploadConfigFilesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Row definition for the package uploading table"
|
|
INDEX { mgnt2CnfUploadConfigIndex }
|
|
::= { mgnt2CnfUploadConfigFilesTable 1 }
|
|
|
|
Mgnt2CnfUploadConfigFilesEntry::=
|
|
SEQUENCE {
|
|
mgnt2CnfUploadConfigIndex
|
|
Integer32,
|
|
mgnt2CnfConfigFileName
|
|
DisplayString,
|
|
mgnt2CnfConfigSlot
|
|
Integer32,
|
|
mgnt2CnfConfigUpload
|
|
EkiOnOff,
|
|
mgnt2CnfDeleteConfigFile
|
|
EkiOnOff
|
|
}
|
|
|
|
mgnt2CnfUploadConfigIndex OBJECT-TYPE
|
|
SYNTAX Integer32(0..16)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Index of config files"
|
|
::= { mgnt2CnfUploadConfigFilesEntry 1 }
|
|
|
|
mgnt2CnfConfigFileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration filename in RAM:This OID gives the
|
|
name of the configuration file in RAM"
|
|
::= { mgnt2CnfUploadConfigFilesEntry 2 }
|
|
|
|
mgnt2CnfConfigSlot OBJECT-TYPE
|
|
SYNTAX Integer32(0..3)
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration target:This OID defines the target
|
|
slot number for the configuration file"
|
|
::= { mgnt2CnfUploadConfigFilesEntry 3 }
|
|
|
|
mgnt2CnfConfigUpload OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration Upload:This OID uploads the
|
|
configuration file to the specified slot number
|
|
in the PM FLASH"
|
|
::= { mgnt2CnfUploadConfigFilesEntry 4 }
|
|
|
|
mgnt2CnfDeleteConfigFile OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration delete from RAM:This OID deletes the
|
|
configuration file from RAM"
|
|
::= { mgnt2CnfUploadConfigFilesEntry 5 }
|
|
|
|
|
|
|
|
|
|
mgnt2CnfManageConfigFilesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2CnfManageConfigFilesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"List of configuration files uploaded to RAM"
|
|
::= { mgnt2ConfigManagement 2 }
|
|
|
|
mgnt2CnfManageConfigFilesEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2CnfManageConfigFilesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Row definition for the package uploading table"
|
|
INDEX { mgnt2CnfManageConfigIndex }
|
|
::= { mgnt2CnfManageConfigFilesTable 1 }
|
|
|
|
Mgnt2CnfManageConfigFilesEntry::=
|
|
SEQUENCE {
|
|
mgnt2CnfManageConfigIndex
|
|
Integer32,
|
|
mgnt2CnfManageConfigFileID
|
|
DisplayString,
|
|
mgnt2CnfManageConfigFileName
|
|
DisplayString,
|
|
mgnt2CnfModuleSlotNumber
|
|
Integer32,
|
|
mgnt2CnfBackupConfig
|
|
EkiOnOff,
|
|
mgnt2CnfRestoreConfig
|
|
EkiOnOff,
|
|
mgnt2CnfExportConfig
|
|
EkiOnOff,
|
|
mgnt2CnfDeleteConfig
|
|
EkiOnOff
|
|
}
|
|
|
|
mgnt2CnfManageConfigIndex OBJECT-TYPE
|
|
SYNTAX Integer32(0..16)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Index of config file slots"
|
|
::= { mgnt2CnfManageConfigFilesEntry 1 }
|
|
|
|
mgnt2CnfManageConfigFileID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration file ID in FLASH:This OID gives the
|
|
ID of the configuration file in MGNT2 FLASH"
|
|
::= { mgnt2CnfManageConfigFilesEntry 2 }
|
|
|
|
mgnt2CnfManageConfigFileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration file name in FLASH:This OID gives the
|
|
name of the configuration file in MGNT2 FLASH"
|
|
::= { mgnt2CnfManageConfigFilesEntry 3 }
|
|
|
|
mgnt2CnfModuleSlotNumber OBJECT-TYPE
|
|
SYNTAX Integer32(3..6)
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration target:This OID defines the target
|
|
module slot number for the configuration file"
|
|
::= { mgnt2CnfManageConfigFilesEntry 4 }
|
|
|
|
mgnt2CnfBackupConfig OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration backup:This OID backups the
|
|
configuration of the specified module to the
|
|
selected file in MGNT2 FLASH"
|
|
::= { mgnt2CnfManageConfigFilesEntry 5 }
|
|
|
|
mgnt2CnfRestoreConfig OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration Restore:This OID restores the
|
|
configuration of the specified module from the
|
|
selected file in MGNT2 FLASH"
|
|
::= { mgnt2CnfManageConfigFilesEntry 6 }
|
|
|
|
mgnt2CnfExportConfig OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration Export:This OID exports the selected
|
|
file in MGNT2 FLASH to a file in RAM"
|
|
::= { mgnt2CnfManageConfigFilesEntry 7 }
|
|
|
|
|
|
mgnt2CnfDeleteConfig OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration delete from FLASH:This OID deletes the
|
|
configuration file from the MGNT2 FLASH"
|
|
::= { mgnt2CnfManageConfigFilesEntry 8 }
|
|
|
|
|
|
-- *****************************************************************
|
|
--
|
|
-- MGNT2 Remote inventory
|
|
--
|
|
-- *****************************************************************
|
|
|
|
mgnt2RinvHwPlatform OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Hardware inventory:This OID gives the
|
|
Hardware inventory of the Mgnt2 management module"
|
|
::= { mgnt2RemoteInventory 1 }
|
|
|
|
mgnt2RinvSoftwarePackage OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Software package inventory:this OID gives
|
|
the Software package inventory of the Mgnt2
|
|
management module"
|
|
::= { mgnt2RemoteInventory 2 }
|
|
|
|
mgnt2RinvGateware OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Gateware inventory:This OID gives the
|
|
gateware inventory of the Mgnt2 management module"
|
|
::= { mgnt2RemoteInventory 3 }
|
|
|
|
|
|
mgnt2RinvAgent OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Software inventory:This OID gives the
|
|
software inventory of the Mgnt2 management module"
|
|
::= { mgnt2RemoteInventory 4 }
|
|
|
|
mgnt2RinvCraft OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Craft inventory:This OID gives the
|
|
craft inventory of the Mgnt2 management module"
|
|
::= { mgnt2RemoteInventory 5 }
|
|
|
|
mgnt2RinvLinux OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Linux inventory:This OID gives the
|
|
linux inventory of the Mgnt2 management module"
|
|
::= { mgnt2RemoteInventory 6 }
|
|
|
|
EkiPlugInState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Plug-in state"
|
|
SYNTAX INTEGER {
|
|
absent(0),
|
|
loaded(1),
|
|
versionError(2),
|
|
symbolError(3)
|
|
}
|
|
|
|
mgnt2GigmPlugInTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2GigmPlugInEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of Plug-ins present"
|
|
::= { mgnt2RemoteInventory 7 }
|
|
|
|
mgnt2GigmPlugInEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2GigmPlugInEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row Definition for the Plug-ins table"
|
|
INDEX { mgnt2IndexPlugIns }
|
|
::= { mgnt2GigmPlugInTable 1 }
|
|
|
|
Mgnt2GigmPlugInEntry ::=
|
|
SEQUENCE {
|
|
mgnt2IndexPlugIns
|
|
Integer32,
|
|
mgnt2PlugInRinv
|
|
DisplayString,
|
|
mgnt2PollingPresent
|
|
EkiPlugInState,
|
|
mgnt2SnmpPresent
|
|
EkiPlugInState
|
|
}
|
|
|
|
mgnt2IndexPlugIns OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index for PMs table"
|
|
::= { mgnt2GigmPlugInEntry 1 }
|
|
|
|
|
|
mgnt2PlugInRinv OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Plug-in RI:This OID gives the remote inventory of the plug-in"
|
|
::= { mgnt2GigmPlugInEntry 2 }
|
|
|
|
mgnt2PollingPresent OBJECT-TYPE
|
|
SYNTAX EkiPlugInState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Polling present:This OID gives the presence of the polling plug-in"
|
|
::= { mgnt2GigmPlugInEntry 3 }
|
|
|
|
mgnt2SnmpPresent OBJECT-TYPE
|
|
SYNTAX EkiPlugInState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Snmp present:This OID gives the presence of the snmp plug-in"
|
|
::= { mgnt2GigmPlugInEntry 4 }
|
|
|
|
mgnt2RinvBackpanel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Backpanel inventory:This OID gives the
|
|
Backpanel inventory of the chassis"
|
|
::= { mgnt2RemoteInventory 8 }
|
|
|
|
mgnt2RinvFan OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan inventory:This OID gives the
|
|
fan inventory of the chassis"
|
|
::= { mgnt2RemoteInventory 9 }
|
|
|
|
mgnt2RinvUboot OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"U-Boot inventory:This OID gives the
|
|
U-Boot inventory"
|
|
::= { mgnt2RemoteInventory 10 }
|
|
|
|
-- *****************************************************************
|
|
--
|
|
-- MGNT2 Error counters
|
|
--
|
|
-- *****************************************************************
|
|
|
|
|
|
mgnt2GigmErrorCounterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2GigmErrorCounterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of error counters"
|
|
::= { mgnt2ErrorCounters 1 }
|
|
|
|
mgnt2GigmErrorCounterEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2GigmErrorCounterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row Definition for the error counters table"
|
|
INDEX { mgnt2IndexErrorCounter }
|
|
::= { mgnt2GigmErrorCounterTable 1 }
|
|
|
|
Mgnt2GigmErrorCounterEntry ::=
|
|
SEQUENCE {
|
|
mgnt2IndexErrorCounter
|
|
Integer32,
|
|
mgnt2ErrorCounterSlotNumber
|
|
Integer32,
|
|
mgnt2ErrorCounterValue
|
|
Integer32
|
|
}
|
|
|
|
mgnt2IndexErrorCounter OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index for error counters table"
|
|
::= { mgnt2GigmErrorCounterEntry 1 }
|
|
|
|
|
|
mgnt2ErrorCounterSlotNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot number:This OID gives the slot number for the corresponding counter"
|
|
::= { mgnt2GigmErrorCounterEntry 2 }
|
|
|
|
mgnt2ErrorCounterValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count value:This OID gives the value of the error counter"
|
|
::= { mgnt2GigmErrorCounterEntry 3 }
|
|
|
|
|
|
mgnt2GigmResetErrorCounters OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reset error counters:This OID reset the error counters to 0"
|
|
::= { mgnt2ErrorCounters 2 }
|
|
|
|
|
|
-- *****************************************************************
|
|
--
|
|
-- MGNT2 Perf objects
|
|
--
|
|
-- *****************************************************************
|
|
|
|
mgnt2PerfCapabilityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2PerfCapabilityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of Perf capability of PMs plugged in the Chassis"
|
|
::= { mgnt2Perf 1 }
|
|
|
|
mgnt2PerfCapabilityEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2PerfCapabilityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row Definition for the Perf capability table"
|
|
INDEX { mgnt2PerfCapIndexBoards }
|
|
::= { mgnt2PerfCapabilityTable 1 }
|
|
|
|
|
|
|
|
Mgnt2PerfCapabilityEntry ::=
|
|
SEQUENCE {
|
|
mgnt2PerfCapIndexBoards
|
|
Integer32,
|
|
mgnt2PerfCapPosition
|
|
Integer32,
|
|
mgnt2PerfCapName
|
|
DisplayString,
|
|
mgnt2PerfCapStatus
|
|
EkiOnOff,
|
|
mgnt2PerfCapOidEnable
|
|
OBJECT IDENTIFIER
|
|
}
|
|
|
|
|
|
mgnt2PerfCapIndexBoards OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index for Perf cap table"
|
|
::= { mgnt2PerfCapabilityEntry 1 }
|
|
|
|
mgnt2PerfCapPosition OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PM Slot number:This OID gives the slot number in
|
|
which the PM is plugged"
|
|
::= { mgnt2PerfCapabilityEntry 2 }
|
|
|
|
mgnt2PerfCapName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PM name:This OID gives the name of the PM plugged
|
|
in the Mgnt2"
|
|
::= { mgnt2PerfCapabilityEntry 3 }
|
|
|
|
mgnt2PerfCapStatus OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of the perf cap:This OID gives the capability
|
|
of the pm to do performance"
|
|
::= { mgnt2PerfCapabilityEntry 4 }
|
|
|
|
mgnt2PerfCapOidEnable OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OID of the object perf enable:This OID gives the OID of
|
|
the perf enable object of the correspondind mib of the module"
|
|
::= { mgnt2PerfCapabilityEntry 5 }
|
|
|
|
|
|
|
|
|
|
|
|
mgnt2GigmPerf15minSync OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"15 min sync perf : this oid send a 15min sync to all modules"
|
|
::= { mgnt2Perf 2 }
|
|
|
|
mgnt2GigmPerf24hSync OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"15 min sync perf : this oid send a 24h sync to all modules"
|
|
::= { mgnt2Perf 3 }
|
|
|
|
mgnt2PerfResyncNMS OBJECT-TYPE
|
|
SYNTAX Mgnt2PerfResyncValues
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Resync Perf : this oid allows to create an historical perf file for all modules"
|
|
::= { mgnt2Perf 4 }
|
|
|
|
|
|
-- *****************************************************************
|
|
--
|
|
-- MGNT2 Board management
|
|
--
|
|
-- *****************************************************************
|
|
|
|
mgnt2alarms OBJECT IDENTIFIER ::= { mgnt2Hardware 1}
|
|
mgnt2controls OBJECT IDENTIFIER ::= { mgnt2Hardware 2}
|
|
mgnt2config OBJECT IDENTIFIER ::= { mgnt2Hardware 3}
|
|
|
|
|
|
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
--- ALARMS
|
|
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
--- *****************************************************
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the synthAlm0 article
|
|
--- *****************************************************
|
|
mgnt2AlmsynthAlm0 OBJECT IDENTIFIER ::= { mgnt2alarms 0 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmMgntDefFuseB OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Mgnt Fuse B Fail :This OID indicates
|
|
that the fuse of the power input
|
|
B is in fail condition on the Management
|
|
board <Help> Status of the MGNT
|
|
Fuse B <Condtype> MGNT_DEF_FUSE_B
|
|
<Probcause> powerProblem (36) <Alarmtype>
|
|
equipmentAlarm (5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm0 16 }
|
|
|
|
|
|
|
|
mgnt2AlmMgntDefFuseA OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Mgnt Fuse A Fail :This OID indicates
|
|
that the fuse of the power input
|
|
A is in fail condition on the Management
|
|
board <Help> Status of the MGNT
|
|
Fuse A <Condtype> MGNT_DEF_FUSE_A
|
|
<Probcause> powerProblem (36) <Alarmtype>
|
|
equipmentAlarm (5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm0 15 }
|
|
|
|
|
|
|
|
mgnt2AlmDef48b OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Power Input B Present :This OID
|
|
indicates that there is not input
|
|
power on the right power connector
|
|
(B) <Help> This alarm indicates
|
|
if the power input B is present
|
|
(right power connector) <Condtype>
|
|
DEF_48B <Probcause> powerProblem
|
|
(36) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm0 12 }
|
|
|
|
|
|
|
|
mgnt2AlmDef48a OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Power Input A Present :This OID
|
|
indicates that there is not input
|
|
power on the right power connector
|
|
(A) <Help> This alarm indicates
|
|
if the power input B is present
|
|
(left power connector) <Condtype>
|
|
DEF_48A <Probcause> powerProblem
|
|
(36) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm0 11 }
|
|
|
|
|
|
|
|
mgnt2AlmFansFailure OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Chassis Fan Module Failure :This
|
|
OID indicates that at least one
|
|
of the three FAN unit of the FAN
|
|
module is in fail condition <Condtype>
|
|
FANS_FAILURE <Probcause> other(1)
|
|
<Alarmtype> equipmentAlarm (5)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm0 10 }
|
|
|
|
|
|
|
|
mgnt2AlmAbsFailure OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Chassis Management Module Failure
|
|
:This OID indicates that the Chassis
|
|
Management module is in fail condition
|
|
<Condtype> ABS_FAILURE <Probcause>
|
|
other(1) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm0 9 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the synthAlm1 article
|
|
--- *****************************************************
|
|
mgnt2AlmsynthAlm1 OBJECT IDENTIFIER ::= { mgnt2alarms 1 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmAcknowledge OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Alarm Ack. :This OID indicates
|
|
the alarms have been acknowledged
|
|
by the user (locally or remotely)
|
|
<Help> This status indicates
|
|
the alarms have been acknowledged
|
|
by the user (locally or remotely)
|
|
<Condtype> ACKNOWLEDGE <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm1 16 }
|
|
|
|
|
|
|
|
mgnt2AlmCritVisual OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Critical Chassis Alarm :This OID
|
|
indicates at least one Critical
|
|
alarm is active on the complete
|
|
chassis (including TR-FAN, MGNT
|
|
and PM) <Help> This alarm indicates
|
|
at least one Critical alarm is
|
|
active on the complete chassis
|
|
(including TR-FAN, MGNT and PM)
|
|
|
|
<Condtype> CRIT_VISUAL <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm1 3 }
|
|
|
|
|
|
|
|
mgnt2AlmUrgVisual OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Major Chassis Alarm :This OID
|
|
indicates at least one Major alarm
|
|
is active on the complete chassis
|
|
(including TR-FAN, MGNT and PM)
|
|
<Help> This alarm indicates
|
|
at least one Major alarm is active
|
|
on the complete chassis (including
|
|
TR-FAN, MGNT and PM) <Condtype>
|
|
URG_VISUAL <Probcause> other(1)
|
|
<Alarmtype> other (1) <Polarity>
|
|
(2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm1 2 }
|
|
|
|
|
|
|
|
mgnt2AlmNurgVisual OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Minor Chassis Alarm :This OID
|
|
indicates at least one Minor alarm
|
|
is active on the complete chassis
|
|
(including TR-FAN, MGNT and PM)
|
|
<Help> This alarm indicates at
|
|
least one Minor alarm is active
|
|
on the complete chassis (including
|
|
TR-FAN, MGNT and PM) <Condtype>
|
|
NURG_VISUAL <Probcause> other(1)
|
|
<Alarmtype> other (1) <Polarity>
|
|
(2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm1 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the boardMgmntSet1 article
|
|
--- *****************************************************
|
|
mgnt2AlmboardMgmntSet1 OBJECT IDENTIFIER ::= { mgnt2alarms 16 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmPmFanAbsent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FAN module present in Chassis
|
|
:This OID indicates the presence
|
|
of the FAN module in the Chassis.
|
|
<Help> This alarm indicates if
|
|
the FAN module is detected in the
|
|
chassis. <Condtype> PM_FAN_ABSENT
|
|
<Probcause> other(1) <Alarmtype>
|
|
equipmentAlarm (5) <Polarity>
|
|
(2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 14 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot11Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 11
|
|
:This OID indicates the presence
|
|
of a PM in Slot 11 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 11
|
|
<Condtype> PM_SLOT11_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 12 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot10Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 10
|
|
:This OID indicates the presence
|
|
of a PM in Slot 10 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 10
|
|
<Condtype> PM_SLOT10_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 11 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot9Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 9 :This
|
|
OID indicates the presence of a
|
|
PM in Slot 9 of the Chassis .
|
|
<Help> This status indicates
|
|
if a PM is detected in slot 9
|
|
<Condtype> PM_SLOT9_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 10 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot8Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 8 :This
|
|
OID indicates the presence of a
|
|
PM in Slot 8 of the Chassis .
|
|
<Help> This status indicates
|
|
if a PM is detected in slot 8
|
|
<Condtype> PM_SLOT8_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 9 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot7Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 7 :This
|
|
OID indicates the presence of a
|
|
PM in Slot 7 of the Chassis .
|
|
<Help> This status indicates
|
|
if a PM is detected in slot 7
|
|
<Condtype> PM_SLOT7_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 8 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot6Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 6 :This
|
|
OID indicates the presence of a
|
|
PM in Slot 6 of the Chassis .
|
|
<Help> This status indicates
|
|
if a PM is detected in slot 6
|
|
<Condtype> PM_SLOT6_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 7 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot5Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 5 :This
|
|
OID indicates the presence of a
|
|
PM in Slot 5 of the Chassis .
|
|
<Help> This status indicates
|
|
if a PM is detected in slot 5
|
|
<Condtype> PM_SLOT5_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 6 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot4Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 4 :This
|
|
OID indicates the presence of a
|
|
PM in Slot 4 of the Chassis .
|
|
<Help> This status indicates
|
|
if a PM is detected in slot 4
|
|
<Condtype> PM_SLOT4_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 5 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot3Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 3 :This
|
|
OID indicates the presence of a
|
|
PM in Slot 3 of the Chassis .
|
|
<Help> This status indicates
|
|
if a PM is detected in slot 3
|
|
<Condtype> PM_SLOT3_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 4 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot2Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 2 :This
|
|
OID indicates the presence of a
|
|
PM in Slot 2 of the Chassis .
|
|
<Help> This status indicates
|
|
if a PM is detected in slot 2
|
|
<Condtype> PM_SLOT2_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 3 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot1Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 1 :This
|
|
OID indicates the presence of a
|
|
PM in Slot 1 of the Chassis .
|
|
<Help> This status indicates
|
|
if a PM is detected in slot 1
|
|
<Condtype> PM_SLOT1_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 2 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the boardMgmntSet2 article
|
|
--- *****************************************************
|
|
mgnt2AlmboardMgmntSet2 OBJECT IDENTIFIER ::= { mgnt2alarms 17 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot20Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 20
|
|
:This OID indicates the presence
|
|
of a PM in Slot 20 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 20
|
|
<Condtype> PM_SLOT20_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet2 9 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot19Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 19
|
|
:This OID indicates the presence
|
|
of a PM in Slot 19 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 19
|
|
<Condtype> PM_SLOT19_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet2 8 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot18Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 18
|
|
:This OID indicates the presence
|
|
of a PM in Slot 18 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 18
|
|
<Condtype> PM_SLOT18_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet2 7 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot17Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 17
|
|
:This OID indicates the presence
|
|
of a PM in Slot 17 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 17
|
|
<Condtype> PM_SLOT17_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet2 6 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot16Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 16
|
|
:This OID indicates the presence
|
|
of a PM in Slot 16 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 16
|
|
<Condtype> PM_SLOT16_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet2 5 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot15Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 15
|
|
:This OID indicates the presence
|
|
of a PM in Slot 15 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 15
|
|
<Condtype> PM_SLOT15_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet2 4 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot14Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 14
|
|
:This OID indicates the presence
|
|
of a PM in Slot 14 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 14
|
|
<Condtype> PM_SLOT14_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet2 3 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot13Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 13
|
|
:This OID indicates the presence
|
|
of a PM in Slot 13 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 13
|
|
<Condtype> PM_SLOT13_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet2 2 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot12Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 12
|
|
:This OID indicates the presence
|
|
of a PM in Slot 12 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 12
|
|
<Condtype> PM_SLOT12_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet2 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the fanMgmnt article
|
|
--- *****************************************************
|
|
mgnt2AlmfanMgmnt OBJECT IDENTIFIER ::= { mgnt2alarms 20 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmFanFilterAbsent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Dust Filter Presence :This OID
|
|
indicates that the dust filter
|
|
is not present<Help> This alarm
|
|
indicates if the Dust Filter is
|
|
detected in the chassis. <Condtype>
|
|
FAN_FILTER_ABSENT <Probcause> other(1)
|
|
<Alarmtype> equipmentAlarm (5)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanMgmnt 16 }
|
|
|
|
|
|
|
|
mgnt2AlmPbFan6Fail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Unit #6 Failed On Fan Module
|
|
:This OID indicates a failure on
|
|
fan 6. Removal of the fan unit
|
|
or no rotation sets the OID.
|
|
<Help> This alarm indicates if
|
|
the FAN #6 is in fail condition
|
|
<Condtype> PB_FAN6_FAIL <Probcause>
|
|
heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanMgmnt 7 }
|
|
|
|
|
|
|
|
mgnt2AlmPbFan5Fail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Unit #5 Failed On Fan Module
|
|
:This OID indicates a failure on
|
|
fan 5. Removal of the fan unit
|
|
or no rotation sets the OID.
|
|
<Help> This alarm indicates if
|
|
the FAN #5 is in fail condition
|
|
<Condtype> PB_FAN5_FAIL <Probcause>
|
|
heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanMgmnt 6 }
|
|
|
|
|
|
|
|
mgnt2AlmPbFan4Fail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Unit #4 Failed On Fan Module
|
|
:This OID indicates a failure on
|
|
fan 4. Removal of the fan unit
|
|
or no rotation sets the OID.
|
|
<Help> This alarm indicates if
|
|
the FAN #4 is in fail condition
|
|
<Condtype> PB_FAN4_FAIL <Probcause>
|
|
heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanMgmnt 5 }
|
|
|
|
|
|
|
|
mgnt2AlmPbFan3Fail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Unit #3 Failed On Fan Module
|
|
:This OID indicates a failure on
|
|
fan 3. Removal of the fan unit
|
|
or no rotation sets the OID.
|
|
<Help> This alarm indicates if
|
|
the FAN #3 is in fail condition
|
|
<Condtype> PB_FAN3_FAIL <Probcause>
|
|
heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanMgmnt 4 }
|
|
|
|
|
|
|
|
mgnt2AlmPbFan2Fail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Unit #2 Failed On Fan Module
|
|
:This OID indicates a failure on
|
|
fan 2. Removal of the fan unit
|
|
or no rotation sets the OID.
|
|
<Help> This alarm indicates if
|
|
the FAN #2 is in fail condition
|
|
<Condtype> PB_FAN2_FAIL <Probcause>
|
|
heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanMgmnt 3 }
|
|
|
|
|
|
|
|
mgnt2AlmPbFan1Fail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Unit #1 Failed On Fan Module
|
|
:This OID indicates a failure on
|
|
fan 1. Removal of the fan unit
|
|
or no rotation sets the OID.
|
|
<Help> This alarm indicates if
|
|
the FAN #1 is in fail condition
|
|
<Condtype> PB_FAN1_FAIL <Probcause>
|
|
heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanMgmnt 2 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the fanPwrMgmnt article
|
|
--- *****************************************************
|
|
mgnt2AlmfanPwrMgmnt OBJECT IDENTIFIER ::= { mgnt2alarms 24 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmFanDefFuseB OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Fuse B Fail :This OID indicates
|
|
that the fuse of the power input
|
|
B is in fail condition on the Fan
|
|
board <Help> Status of the FAN
|
|
Fuse B <Condtype> FAN_DEF_FUSE_B
|
|
<Probcause> powerProblem (36) <Alarmtype>
|
|
equipmentAlarm (5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanPwrMgmnt 16 }
|
|
|
|
|
|
|
|
mgnt2AlmFanDefFuseA OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Fuse A Fail :This OID indicates
|
|
that the fuse of the power input
|
|
A is in fail condition on the Fan
|
|
board <Help> Status of the FAN
|
|
Fuse A <Condtype> FAN_DEF_FUSE_A
|
|
<Probcause> powerProblem (36) <Alarmtype>
|
|
equipmentAlarm (5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanPwrMgmnt 15 }
|
|
|
|
|
|
|
|
mgnt2AlmFanPwrFail1 OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Main Power :This OID indicates
|
|
a failure on the main power of
|
|
the FAN module <Help> This
|
|
alarm indicates if one of the
|
|
tow main power convert of the
|
|
FAN module is in fail condition
|
|
<Condtype> FAN_PWR_FAIL_1 <Probcause>
|
|
powerProblem (36) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanPwrMgmnt 13 }
|
|
|
|
|
|
|
|
mgnt2AlmFanPwrProtOn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Backup Power :This OID indicates
|
|
the backup power on the FAN module
|
|
is switched on <Condtype> FAN_PWR_PROT_ON
|
|
<Probcause> powerProblem (36) <Alarmtype>
|
|
equipmentAlarm (5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanPwrMgmnt 12 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the removeablefanModuleFail article
|
|
--- *****************************************************
|
|
mgnt2AlmremoveablefanModuleFail OBJECT IDENTIFIER ::= { mgnt2alarms 25 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmFan4ModuleAbsent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FAN Module #4 Present In Chassis
|
|
:This OID indicates the presence
|
|
of the FAN module #4 in the Chassis.<Help>
|
|
This alarm indicates if the FAN
|
|
module #4 is detected in the chassis.
|
|
<Condtype> FAN4_MODULE_ABSENT <Probcause>
|
|
other(1) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmremoveablefanModuleFail 4 }
|
|
|
|
|
|
|
|
mgnt2AlmFan3ModuleAbsent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FAN Module #3 Present In Chassis
|
|
:This OID indicates the presence
|
|
of the FAN module #3 in the Chassis.<Help>
|
|
This alarm indicates if the FAN
|
|
module #3 is detected in the chassis.
|
|
<Condtype> FAN3_MODULE_ABSENT <Probcause>
|
|
other(1) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmremoveablefanModuleFail 3 }
|
|
|
|
|
|
|
|
mgnt2AlmFan2ModuleAbsent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FAN Module #2 Present In Chassis
|
|
:This OID indicates the presence
|
|
of the FAN module #2 in the Chassis.<Help>
|
|
This alarm indicates if the FAN
|
|
module #2 is detected in the chassis.
|
|
<Condtype> FAN2_MODULE_ABSENT <Probcause>
|
|
other(1) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmremoveablefanModuleFail 2 }
|
|
|
|
|
|
|
|
mgnt2AlmFan1ModuleAbsent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FAN Module #1 Present In Chassis
|
|
:This OID indicates the presence
|
|
of the FAN module #1 in the Chassis.<Help>
|
|
This alarm indicates if the FAN
|
|
module #1 is detected in the chassis.
|
|
<Condtype> FAN1_MODULE_ABSENT <Probcause>
|
|
other(1) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmremoveablefanModuleFail 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the removeableFanModuleMgmnt article
|
|
--- *****************************************************
|
|
mgnt2AlmremoveableFanModuleMgmnt OBJECT IDENTIFIER ::= { mgnt2alarms 26 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmFan4ModuleFail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FAN Module #4 Failure :This OID
|
|
indicates a failure on FAN module
|
|
#4 <Help> This alarm indicates
|
|
if the FAN module #4 is in fail
|
|
condition <Condtype> FAN4_MODULE_FAIL
|
|
<Probcause> heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmremoveableFanModuleMgmnt 4 }
|
|
|
|
|
|
|
|
mgnt2AlmFan3ModuleFail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FAN Module #3 Failure :This OID
|
|
indicates a failure on FAN module
|
|
#3 <Help> This alarm indicates
|
|
if the FAN module #3 is in fail
|
|
condition <Condtype> FAN3_MODULE_FAIL
|
|
<Probcause> heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmremoveableFanModuleMgmnt 3 }
|
|
|
|
|
|
|
|
mgnt2AlmFan2ModuleFail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FAN Module #2 Failure :This OID
|
|
indicates a failure on FAN module
|
|
#2 <Help> This alarm indicates
|
|
if the FAN module #2 is in fail
|
|
condition <Condtype> FAN2_MODULE_FAIL
|
|
<Probcause> heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmremoveableFanModuleMgmnt 2 }
|
|
|
|
|
|
|
|
mgnt2AlmFan1ModuleFail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FAN Module #1 Failure :This OID
|
|
indicates a failure on FAN module
|
|
#1 <Help> This alarm indicates
|
|
if the FAN module #1 is in fail
|
|
condition <Condtype> FAN1_MODULE_FAIL
|
|
<Probcause> heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmremoveableFanModuleMgmnt 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the swAlarm1 article
|
|
--- *****************************************************
|
|
mgnt2AlmswAlarm1 OBJECT IDENTIFIER ::= { mgnt2alarms 32 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmPollingManagerError OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Polling Manager fail :This OID
|
|
indicates a failure on the Manager
|
|
polling the PM's <Help>
|
|
<Help> This alarm indicates if
|
|
there is a polling manager failure
|
|
between the MGNT and the Pm's <Condtype>
|
|
POLLING_MANAGER_ERROR <Probcause>
|
|
adapterError (2) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmswAlarm1 3 }
|
|
|
|
|
|
|
|
mgnt2AlmFifoCmdError OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
SNMP Agent to Transport comm FIFO
|
|
fail :This OID indicates a failure
|
|
inside the FIFO stack. The FIFO
|
|
containing the messages from
|
|
the agent (write) to the PMs is
|
|
full <Help> This alarm indicates
|
|
if there is a communication mismatch
|
|
between the MGNT board and all
|
|
PM <Condtype> FIFO_CMD_ERROR <Probcause>
|
|
adapterError (2) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmswAlarm1 2 }
|
|
|
|
|
|
|
|
mgnt2AlmApiError OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Comm fail between Agent and Transport
|
|
:This OID indicates a failure detected
|
|
on the Agent.The failure is
|
|
located on a communication process
|
|
with the modules. <Help> This
|
|
alarm indicates if there is a communication
|
|
mismatch between the MGNT board
|
|
and a single PM <Condtype> API_ERROR
|
|
<Probcause> adapterError (2) <Alarmtype>
|
|
equipmentAlarm (5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmswAlarm1 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the apiErrorCode article
|
|
--- *****************************************************
|
|
|
|
mgnt2AlmapiErrorCode OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
API Error Identification :Error
|
|
number and description of the abs1AlmApiError
|
|
object <Condtype> API_ERROR_CODE_1
|
|
<Probcause> <Alarmtype>
|
|
"
|
|
::= { mgnt2alarms 33 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the logMgmnt article
|
|
--- *****************************************************
|
|
mgnt2AlmlogMgmnt OBJECT IDENTIFIER ::= { mgnt2alarms 34 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmLog80Full OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Log File Full Warning :This OID
|
|
indicates that a log file is 80%
|
|
full. <Help> This alarm indicates
|
|
that one of the log file is 80%
|
|
Full <Condtype> LOG_80_FULL <Probcause>
|
|
fileError (18) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmlogMgmnt 2 }
|
|
|
|
|
|
|
|
mgnt2AlmLogFileFull OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Log File Full Alarm :This OID
|
|
indicates that a log file is full.
|
|
This file must be cleared to insure
|
|
correct log function <Help> This
|
|
alarm indicates that one of the
|
|
log file is Full <Condtype> LOG_FILE_FULL
|
|
<Probcause> fileError (18) <Alarmtype>
|
|
equipmentAlarm (5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmlogMgmnt 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the ntpSyncLoss article
|
|
--- *****************************************************
|
|
mgnt2AlmntpSyncLoss OBJECT IDENTIFIER ::= { mgnt2alarms 35 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmCpuTempOverRange OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
CPU HighTemperature Warning :This
|
|
OID indicates a temperature over
|
|
the expected range on the CPU<Help>
|
|
This warning indicates that the
|
|
temperature of the CPU is reaching
|
|
its internal limit <Condtype> CPU_TEMP_OVER_RANGE
|
|
<Probcause> other(1) <Alarmtype>
|
|
equipmentAlarm (5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmntpSyncLoss 2 }
|
|
|
|
|
|
|
|
mgnt2AlmNtpSyncLoss OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
NTP Sync Loss :This OID indicates
|
|
a loss of synchronisation with
|
|
the NTP Server. <Help> This
|
|
alarm indicates a loss of synchronisation
|
|
with the NTP Server. <Condtype>
|
|
NTP_SYNC_LOSS <Probcause> timingProblem
|
|
(53) <Alarmtype> timeDomainViolation
|
|
(11) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmntpSyncLoss 1 }
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
--- CONTROLS
|
|
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
--- *****************************************************
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the synth5 article
|
|
--- *****************************************************
|
|
mgnt2Ctrlsynth5 OBJECT IDENTIFIER ::= { mgnt2controls 5 }
|
|
|
|
|
|
|
|
|
|
mgnt2CtrlChassisColdReset OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Cold Reset of the Management Module
|
|
:This oid triggers a 'cold' reset
|
|
of the Chassis . This type of reset
|
|
is not traffic affecting and the
|
|
modules configuration remains
|
|
unchanged. <Help> This control
|
|
initiates a cold reset of the MGNT
|
|
board,
|
|
"
|
|
::= { mgnt2Ctrlsynth5 4 }
|
|
|
|
|
|
|
|
mgnt2CtrlChassisWarmReset OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Reset of the Management Module
|
|
:This oid triggers a 'warm' reset
|
|
of the Chassis . This type of reset
|
|
is not traffic affecting and the
|
|
modules configuration remains
|
|
unchanged. <Help> This control
|
|
initiates a warm reset of the MGNT
|
|
board,
|
|
"
|
|
::= { mgnt2Ctrlsynth5 3 }
|
|
|
|
|
|
|
|
mgnt2CtrlChassisShutdown OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Shut Down of the Management Module
|
|
:This OID shall be set before shutting
|
|
down the Chassis power. A delay
|
|
of 5 sec is necessary between this
|
|
OID is set and power is shut down.
|
|
<Help> This control initiates
|
|
a shutdown of the MGNT board,
|
|
"
|
|
::= { mgnt2Ctrlsynth5 2 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the testLed article
|
|
--- *****************************************************
|
|
mgnt2CtrltestLed OBJECT IDENTIFIER ::= { mgnt2controls 18 }
|
|
|
|
|
|
|
|
|
|
mgnt2CtrlLedOff OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Switch off Leds Test :This OID
|
|
switches off all the Leds as a
|
|
test feature <Help> This control
|
|
initiates a test leds turning all
|
|
the LEDs of the complete chassis
|
|
to OFF
|
|
"
|
|
::= { mgnt2CtrltestLed 3 }
|
|
|
|
|
|
|
|
mgnt2CtrlRedLed OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Red Leds Test :This OID switches
|
|
on all the red Leds as a test feature
|
|
<Help> This control initiates
|
|
a test leds turning all the LEDs
|
|
of the chassis to red
|
|
"
|
|
::= { mgnt2CtrltestLed 2 }
|
|
|
|
|
|
|
|
mgnt2CtrlGreenLed OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Green Leds Test :This OID switches
|
|
on all the green Leds as a test
|
|
feature <Help> This control initiates
|
|
a test leds turning all the LEDs
|
|
of the chassis to green
|
|
"
|
|
::= { mgnt2CtrltestLed 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the logFile article
|
|
--- *****************************************************
|
|
mgnt2CtrllogFile OBJECT IDENTIFIER ::= { mgnt2controls 19 }
|
|
|
|
|
|
|
|
|
|
mgnt2CtrlLogFileReset OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Log File Reset :This OID clears
|
|
all the log files
|
|
"
|
|
::= { mgnt2CtrllogFile 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the mgntSaveConfig article
|
|
--- *****************************************************
|
|
mgnt2CtrlmgntSaveConfig OBJECT IDENTIFIER ::= { mgnt2controls 23 }
|
|
|
|
|
|
|
|
|
|
mgnt2CtrlSaveConfig OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Save Configuration :This OID is
|
|
used save the configuration related
|
|
to the enable and mode traps objects
|
|
<Help> This control saves the
|
|
customer configuration on the MGNT
|
|
board
|
|
"
|
|
::= { mgnt2CtrlmgntSaveConfig 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the mgntGetGlobalConfig article
|
|
--- *****************************************************
|
|
mgnt2CtrlmgntGetGlobalConfig OBJECT IDENTIFIER ::= { mgnt2controls 24 }
|
|
|
|
|
|
|
|
|
|
mgnt2CtrlGetGlobalConfig OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Get Global Chassis Config :This
|
|
OID is used to create a global
|
|
configuration file of the chassis
|
|
<Help> This control creates a
|
|
single configuration file from
|
|
PM's and MGNT configuration file
|
|
into the RAM
|
|
"
|
|
::= { mgnt2CtrlmgntGetGlobalConfig 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the mgntPutGlobalConfig article
|
|
--- *****************************************************
|
|
mgnt2CtrlmgntPutGlobalConfig OBJECT IDENTIFIER ::= { mgnt2controls 25 }
|
|
|
|
|
|
|
|
|
|
mgnt2CtrlPutGlobalConfig OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Put Global Chassis Config :This
|
|
OID is used to extract a global
|
|
configuration file of the chassis
|
|
<Help> This control creates configuration
|
|
files to PM's and MGNT from a
|
|
single configuration file in the
|
|
RAM
|
|
"
|
|
::= { mgnt2CtrlmgntPutGlobalConfig 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the mgntAcknowledge article
|
|
--- *****************************************************
|
|
mgnt2CtrlmgntAcknowledge OBJECT IDENTIFIER ::= { mgnt2controls 26 }
|
|
|
|
|
|
|
|
|
|
mgnt2CtrlAcknowledge OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Alarm Ack. :This OID is used to
|
|
acknowledge the current active
|
|
alarms of the chassis <Help>
|
|
This control is used to acknowledge
|
|
the current active alarms of the
|
|
chassis
|
|
"
|
|
::= { mgnt2CtrlmgntAcknowledge 1 }
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
--- CONFIG
|
|
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
--- *****************************************************
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the ethPort2 article
|
|
--- *****************************************************
|
|
mgnt2CfgethPort2 OBJECT IDENTIFIER ::= { mgnt2config 17 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgChassisEthernetSplit OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Chassis Ethernet Split :This
|
|
OID enables the split between
|
|
the two kendings. <Help> Enable/Disable
|
|
the switch between the two kendings
|
|
"
|
|
::= { mgnt2CfgethPort2 2 }
|
|
|
|
|
|
|
|
mgnt2CfgEthPort2Disable OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
2nd Ethernet Port Disable :This
|
|
OID disables 'Ethernet Port 2'
|
|
.When not required, this port
|
|
must be disabled in order to
|
|
prevent unwanted access. <Help>
|
|
Disable the second Ethernet port
|
|
"
|
|
::= { mgnt2CfgethPort2 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the mgntDccEnable article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgmgntDccEnable OBJECT-TYPE
|
|
SYNTAX Mgnt2DccAccessValues
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
DCC Access :This OID selects
|
|
the mode to enable the DCC on
|
|
the slots. This Mode enables the
|
|
Slots 2-4-6-8-10 , or the Slots
|
|
2-6-10-14-18. <Help> Defines
|
|
the DCC access on the backplane
|
|
of the chassis (Slots 2-4-6-8-10
|
|
or Slots 2-6-10-14-18)
|
|
"
|
|
::= { mgnt2config 18 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the pmTrapEnable article
|
|
--- *****************************************************
|
|
mgnt2CfgpmTrapEnable OBJECT IDENTIFIER ::= { mgnt2config 20 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgPmConfigTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Config Traps Enable :This OID,
|
|
when set, enables the generation
|
|
of a trap when the configuration
|
|
of a PM plugged in the chassis
|
|
is modified <Help> In detailed
|
|
traps mechanism, enable the trap
|
|
emission on PM configuration modificatio
|
|
"
|
|
::= { mgnt2CfgpmTrapEnable 6 }
|
|
|
|
|
|
|
|
mgnt2CfgPmControlTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Control Traps Enable :This OID,
|
|
when set, enables the generation
|
|
of a trap when a control is sent
|
|
to a PM plugged in the chassis
|
|
|
|
<Help> In detailed traps
|
|
mechanism, enable the trap emission
|
|
on control sent to PM
|
|
"
|
|
::= { mgnt2CfgpmTrapEnable 5 }
|
|
|
|
|
|
|
|
mgnt2CfgPmMinorTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Minor Alarm Traps Enable :This
|
|
OID, when set, enables the generation
|
|
of the minor alarm trap for all
|
|
the PM plugged in the chassis
|
|
<Help> In detailed traps mechanism,
|
|
enable the trap emission on minor
|
|
alarm detected on PM
|
|
"
|
|
::= { mgnt2CfgpmTrapEnable 3 }
|
|
|
|
|
|
|
|
mgnt2CfgPmMajorTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Major Alarm Traps Enable :This
|
|
OID, when set, enables the generation
|
|
of the major alarm trap for all
|
|
the PM plugged in the chassis
|
|
<Help> In detailed traps mechanism,
|
|
enable the trap emission on major
|
|
alarm detected on PM
|
|
"
|
|
::= { mgnt2CfgpmTrapEnable 2 }
|
|
|
|
|
|
|
|
mgnt2CfgPmCriticalTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Critical Alarm Traps Enable :This
|
|
OID, when set, enables the generation
|
|
of the critical alarm trap for
|
|
all the PM plugged in the chassis
|
|
<Help> In detailed traps mechanism,
|
|
enable the trap emission on critical
|
|
alarm detected on PM
|
|
"
|
|
::= { mgnt2CfgpmTrapEnable 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the mgntTrapEnable article
|
|
--- *****************************************************
|
|
mgnt2CfgmgntTrapEnable OBJECT IDENTIFIER ::= { mgnt2config 21 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgMgntEventTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
MGNT Event Traps Enable :This
|
|
OID, when set, enables the generation
|
|
of a trap when an event occurs
|
|
on the chassis <Help> In detailed
|
|
traps mechanism, enable the trap
|
|
emission on event detected in the
|
|
chassis
|
|
"
|
|
::= { mgnt2CfgmgntTrapEnable 7 }
|
|
|
|
|
|
|
|
mgnt2CfgMgntConfigTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
MGNT Config Traps Enable :This
|
|
OID, when set, enables the generation
|
|
of a trap when the configuration
|
|
of a MGNT plugged in the chassis
|
|
is modified <Help> In detailed
|
|
traps mechanism, enable the trap
|
|
emission on MGNT configuration
|
|
modification
|
|
"
|
|
::= { mgnt2CfgmgntTrapEnable 6 }
|
|
|
|
|
|
|
|
mgnt2CfgMgntControlTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
MGNT Control Traps Enable :This
|
|
OID, when set, enables the generation
|
|
of a trap when a control is sent
|
|
to a MGNT plugged in the chassis
|
|
|
|
<Help> In detailed traps
|
|
mechanism, enable the trap emission
|
|
on control sent to MGNT
|
|
"
|
|
::= { mgnt2CfgmgntTrapEnable 5 }
|
|
|
|
|
|
|
|
mgnt2CfgMgntMinorTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
MGNT Minor Alarm Traps Enable
|
|
:This OID, when set, enables the
|
|
generation of the minor alarm trap
|
|
for the MGNT and FAN board <Help>
|
|
In detailed traps mechanism, enable
|
|
the trap emission on minor alarm
|
|
detected on MGNT and FAN
|
|
"
|
|
::= { mgnt2CfgmgntTrapEnable 3 }
|
|
|
|
|
|
|
|
mgnt2CfgMgntMajorTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
MGNT Major Traps Enable :This
|
|
OID, when set, enables the generation
|
|
of the major alarm trap for the
|
|
MGNT and FAN board <Help> In
|
|
detailed traps mechanism, enable
|
|
the trap emission on major alarm
|
|
detected on MGNT and FAN
|
|
"
|
|
::= { mgnt2CfgmgntTrapEnable 2 }
|
|
|
|
|
|
|
|
mgnt2CfgMgntCriticalTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
MGNT Critical Alarm Traps Enable
|
|
:This OID, when set, enables the
|
|
generation of the critical alarm
|
|
trap for the MGNT and FAN board
|
|
<Help> In detailed traps mechanism,
|
|
enable the trap emission on critical
|
|
alarm detected on MGNT and FAN
|
|
"
|
|
::= { mgnt2CfgmgntTrapEnable 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the mgntTrapMode article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgmgntTrapMode OBJECT-TYPE
|
|
SYNTAX Mgnt2TrapModeValues
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Traps Mode :This OID is used to
|
|
define the trap mode (synthetic
|
|
or detailed mode) <Help> Selects
|
|
the traps mechanism
|
|
"
|
|
::= { mgnt2config 22 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the syslogEnable article
|
|
--- *****************************************************
|
|
mgnt2CfgsyslogEnable OBJECT IDENTIFIER ::= { mgnt2config 23 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgSyslogAlarmEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Syslog Alarm Enable :This OID,
|
|
when set, enables the generation
|
|
of a syslog, when an alarm occurs
|
|
<Help> Enable a syslog emission
|
|
on an alarm detected on the chassi
|
|
"
|
|
::= { mgnt2CfgsyslogEnable 4 }
|
|
|
|
|
|
|
|
mgnt2CfgSyslogCtrlEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Syslog Control Enable :This OID,
|
|
when set, enables the generation
|
|
of a syslog, when a control is
|
|
set <Help> Enable a syslog
|
|
emission on a control operated
|
|
on the chassis
|
|
"
|
|
::= { mgnt2CfgsyslogEnable 3 }
|
|
|
|
|
|
|
|
mgnt2CfgSyslogConfigEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Syslog Config Enable :This OID,
|
|
when set, enables the generation
|
|
of a syslog, when the configuration
|
|
has been changed. <Help> Enable
|
|
a syslog emission on a configuration
|
|
change detected on the chassis
|
|
"
|
|
::= { mgnt2CfgsyslogEnable 2 }
|
|
|
|
|
|
|
|
mgnt2CfgSyslogEventEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Syslog Event Enable :This OID,
|
|
when set, enables the generation
|
|
of a syslog, when an event has
|
|
been detected <Help> Enable
|
|
a syslog emission on event detected
|
|
on the chassis
|
|
"
|
|
::= { mgnt2CfgsyslogEnable 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the ntpTimeZone article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgntpTimeZone OBJECT-TYPE
|
|
SYNTAX INTEGER (-12..12)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
NTP Time Zone :This OID defines
|
|
the time zone of the MGNT board
|
|
for the NTP server <Help> This
|
|
object defines the time zone of
|
|
the MGNT board (from -12 to +12
|
|
hours from the GMT).
|
|
"
|
|
::= { mgnt2config 24 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the pmConfEnable article
|
|
--- *****************************************************
|
|
mgnt2CfgpmConfEnable OBJECT IDENTIFIER ::= { mgnt2config 25 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgPmRestoreEnable OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Automatic Config Restore :This
|
|
OID enables the automatic PM configuration
|
|
restore mechanism on PM insertion
|
|
<Help> This parameter enables
|
|
the automatic PM configuration
|
|
restore mechanism on PM insertio
|
|
"
|
|
::= { mgnt2CfgpmConfEnable 2 }
|
|
|
|
|
|
|
|
mgnt2CfgPmBackupEnable OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Automatic Config Backup :This
|
|
OID enables the automatic PM configuration
|
|
backup mechanism on PM insertion
|
|
or PM configuration modification.
|
|
<Help> This parameter enables
|
|
the automatic PM configuration
|
|
backup mechanism on PM insertion
|
|
or PM configuration modificatio
|
|
"
|
|
::= { mgnt2CfgpmConfEnable 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the inactivityTimeout article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfginactivityTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (-1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Idle Timeout :This OID defines
|
|
the idle timeout (in minutes) to
|
|
automatically logout from the craft
|
|
and from the CLI. <Help> This
|
|
object defines the idle timeout
|
|
(in minutes) to automatically logout
|
|
from the craft and from the CLI
|
|
"
|
|
::= { mgnt2config 26 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the cliAccess article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgcliAccess OBJECT-TYPE
|
|
SYNTAX Mgnt2CliAccessValues
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
CLI access :This OID selects
|
|
the protocol for the remote access
|
|
to a CLI user. <Help> This object
|
|
defines the protocol used for a
|
|
remote CLI.
|
|
"
|
|
::= { mgnt2config 27 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the craftAccess article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgcraftAccess OBJECT-TYPE
|
|
SYNTAX Mgnt2CraftAccessValues
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
CRAFT access :This OID selects
|
|
the remote access to a CRAFT user.
|
|
<Help> This object defines the
|
|
access for a remote CRAFT.
|
|
"
|
|
::= { mgnt2config 28 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the perfModes1 article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgperfModes1 OBJECT-TYPE
|
|
SYNTAX EkiSynchroMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PERF Synchro Source :This OID
|
|
selects the source of the synchronisation
|
|
(Internal/External). <Help> This
|
|
object defines the source of the
|
|
synchronization to operate performance
|
|
monitoring.
|
|
"
|
|
::= { mgnt2config 29 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the alarmModelActiv article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgalarmModelActiv OBJECT-TYPE
|
|
SYNTAX Mgnt2AckMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Acknowledge mode :This OID defines
|
|
the alarms akcnowledge mode <Help>
|
|
This configuration defines the
|
|
alarms akcnowledge mode
|
|
"
|
|
::= { mgnt2config 30 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the networkInput article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgnetworkInput OBJECT-TYPE
|
|
SYNTAX Mgnt2NetMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Network input :This OID selects
|
|
the connection of the Ethernet
|
|
Network input to either the switches
|
|
(2) or the daughter board (1) ,
|
|
in this case the MGNT can act as
|
|
a router <Help> This configuration
|
|
defines the use of the Network
|
|
input of the front panel
|
|
"
|
|
::= { mgnt2config 31 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the masterEthMode article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgmasterEthMode OBJECT-TYPE
|
|
SYNTAX Mgnt2MasterEthMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
DHCP Master Ethernet Mode :This
|
|
OID selects the mode of the Master
|
|
Ethernet in DHCP mode (2) or in
|
|
Static Mode(1) <Help> This configuration
|
|
defines the use of the Master Ethernet
|
|
Mode
|
|
"
|
|
::= { mgnt2config 32 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the subnetMode article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgsubnetMode OBJECT-TYPE
|
|
SYNTAX Mgnt2SubnetEthMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
DHCP Subnet Mode :This OID selects
|
|
the mode of the Subnet in DHCP
|
|
mode (2) or in Static Mode(1)
|
|
<Help> This configuration defines
|
|
the use of the Subnet Mode
|
|
"
|
|
::= { mgnt2config 33 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the rstpMode article
|
|
--- *****************************************************
|
|
mgnt2CfgrstpMode OBJECT IDENTIFIER ::= { mgnt2config 34 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgRstpEnable OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
RSTP Enable :This OID enables
|
|
the RSTP algorythm <Help> This
|
|
configuration defines the use of
|
|
RSTP
|
|
"
|
|
::= { mgnt2CfgrstpMode 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the lldpMode article
|
|
--- *****************************************************
|
|
mgnt2CfglldpMode OBJECT IDENTIFIER ::= { mgnt2config 35 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgLldpEnable OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
LLDP Enable :This OID enables
|
|
the LLDP algorythm <Help> This
|
|
configuration defines the use of
|
|
LLDP
|
|
"
|
|
::= { mgnt2CfglldpMode 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the logMode article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfglogMode OBJECT-TYPE
|
|
SYNTAX Mgnt2LogFileMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Log Mode :This OID enables the
|
|
log file mode<Help> This configuration
|
|
defines the use of the log mod
|
|
"
|
|
::= { mgnt2config 36 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the nodeMode article
|
|
--- *****************************************************
|
|
mgnt2CfgnodeMode OBJECT IDENTIFIER ::= { mgnt2config 37 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgNodeControllerEnable OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Node Controller Mode :This OID
|
|
enables the node controller mode<Help>
|
|
This configuration defines the
|
|
use of the node controller mod
|
|
"
|
|
::= { mgnt2CfgnodeMode 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the unprivilegedUsersMode article
|
|
--- *****************************************************
|
|
mgnt2CfgunprivilegedUsersMode OBJECT IDENTIFIER ::= { mgnt2config 38 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgRestrictUnprivilegeUsers OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Restrict Unprivileged Users Rights
|
|
:This OID enables the restriction
|
|
of unprivileged user rights to
|
|
modify their own password <Help>
|
|
This parameter enables the restriction
|
|
of unprivileged user rights to
|
|
modify their own password
|
|
"
|
|
::= { mgnt2CfgunprivilegedUsersMode 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the oscDccLinkUpThreshold article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgoscDccLinkUpThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
OSC/DCC Link Up Thresh. [10-30]s
|
|
:This OID defines the confirmation
|
|
threshold to consider an OSC/DCC
|
|
link as up <Help> This parameter
|
|
defines the confirmation threshold
|
|
to consider an OSC/DCC link as
|
|
up
|
|
"
|
|
::= { mgnt2config 39 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the oscDccLinkDownThreshold article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgoscDccLinkDownThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
OSC/DCC Link Down Thresh. [2-3]s
|
|
:This OID defines the confirmation
|
|
threshold to consider an OSC/DCC
|
|
link as down <Help> This parameter
|
|
defines the confirmation threshold
|
|
to consider an OSC/DCC link as
|
|
down.
|
|
"
|
|
::= { mgnt2config 40 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the accountAutoLock article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgaccountAutoLock OBJECT-TYPE
|
|
SYNTAX INTEGER (-1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Account Auto-Lock [-1 / 1-10]
|
|
err :This OID defines the number
|
|
of error password to lock an account.
|
|
This counter is reset on successful
|
|
login or after an administrator
|
|
defined period (see Fail count
|
|
reset) Set to -1 to disables the
|
|
feature.<Help> This parameter defines
|
|
the number of error password to
|
|
lock an account. This counter is
|
|
reset on successful login or after
|
|
an administrator defined period
|
|
(see Fail count reset) Set to -1
|
|
to disables the feature.
|
|
"
|
|
::= { mgnt2config 41 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the failCountReset article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgfailCountReset OBJECT-TYPE
|
|
SYNTAX INTEGER (-1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fail Count Reset [-1 / 1-10] hrs
|
|
:This OID defines the minimum time
|
|
(in hours) to reset the failed
|
|
login counter. This counter is
|
|
also reset on successful login.
|
|
Set to -1 to disable the feature.<Help>
|
|
This parameter defines the minimum
|
|
time (in hours) to reset the failed
|
|
login counter. This counter is
|
|
also reset on successful login.
|
|
Set to -1 to disable the feature
|
|
"
|
|
::= { mgnt2config 42 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the ftpMode article
|
|
--- *****************************************************
|
|
mgnt2CfgftpMode OBJECT IDENTIFIER ::= { mgnt2config 44 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgFtpEnable OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FTP Enable :This OID enables the
|
|
FTP protocol <Help> This configuration
|
|
enables the FTP protocol
|
|
"
|
|
::= { mgnt2CfgftpMode 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the tftpMode article
|
|
--- *****************************************************
|
|
mgnt2CfgtftpMode OBJECT IDENTIFIER ::= { mgnt2config 45 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgTftpEnable OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
TFTP Enable :This OID enables
|
|
the TFTP protocol <Help> This
|
|
configuration enables the TFTP
|
|
protocol
|
|
"
|
|
::= { mgnt2CfgtftpMode 1 }
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- TRAPS
|
|
--- *****************************************************
|
|
|
|
mgnt2TrapBoardNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(1..16)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the slot number of the PM that sent the last trap"
|
|
::= { mgnt2Traps 50 }
|
|
|
|
mgnt2TrapSeverity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the trap severity"
|
|
::= { mgnt2Traps 51 }
|
|
|
|
mgnt2TrapSourcePm OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the mnemonic of the pm who sent a trap"
|
|
::= { mgnt2Traps 52 }
|
|
|
|
mgnt2TrapSourcePortType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the type of the port who sent a trap"
|
|
::= { mgnt2Traps 53 }
|
|
|
|
mgnt2TrapSourcePortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(1..16)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the port number of the PM that sent the last trap"
|
|
::= { mgnt2Traps 54 }
|
|
|
|
mgnt2TrapSourceLabel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the label of the alarm who sent a trap"
|
|
::= { mgnt2Traps 55 }
|
|
|
|
mgnt2TrapSourceValue OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the value of the alarm who sent a trap"
|
|
::= { mgnt2Traps 56 }
|
|
|
|
mgnt2TrapEventLabel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the label of the event"
|
|
::= { mgnt2Traps 57 }
|
|
|
|
mgnt2TrapNodeControllerIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the IP address of the Node Controller"
|
|
::= { mgnt2Traps 58 }
|
|
|
|
mgnt2TrapChassisId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the chassis ID "
|
|
::= { mgnt2Traps 59 }
|
|
|
|
mgnt2TrapApi NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2TrapBoardNumber,mgnt2AlmapiErrorCode}
|
|
STATUS current
|
|
--&FILTNAME "API Error"
|
|
--&ACTIONS { log, minor }
|
|
--&MATCH { mgnt2TrapBoardNumber "$1", mgnt2AlmapiErrorCode "$2"}
|
|
--&MESG "API Error number $2 received from Board in slot $1 ($A)"
|
|
DESCRIPTION "Api error trap with its number"
|
|
::= { mgnt2Traps 1 }
|
|
|
|
mgnt2TrapSwError NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2AlmFifoCmdError}
|
|
STATUS current
|
|
--&FILTNAME "SW Error"
|
|
--&ACTIONS { log, minor }
|
|
--&MATCH { mgnt2AlmFifoCmdError "$1"}
|
|
--&MESG "Software Error detected"
|
|
DESCRIPTION "Chassis software error other API"
|
|
::= { mgnt2Traps 2 }
|
|
|
|
mgnt2TrapBoardInserted NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2TrapBoardNumber}
|
|
STATUS current
|
|
--&FILTNAME "Board Inserted"
|
|
--&ACTIONS { log, info }
|
|
--&MATCH { mgnt2TrapBoardNumber "$1"}
|
|
--&MESG "Board Inserted in Slot $1 ($A)"
|
|
DESCRIPTION "A board has been plugged in"
|
|
::= { mgnt2Traps 4}
|
|
|
|
mgnt2TrapBoardRemoved NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2TrapBoardNumber}
|
|
STATUS current
|
|
--&FILTNAME "Board Removed"
|
|
--&ACTIONS { log, info }
|
|
--&MATCH { mgnt2TrapBoardNumber "$1"}
|
|
--&MESG "Board Removed from Slot $1 ($A)"
|
|
DESCRIPTION "A board has been plugged out"
|
|
::= { mgnt2Traps 5 }
|
|
|
|
mgnt2TrapRestoreConfDone NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2TrapBoardNumber}
|
|
STATUS current
|
|
--&FILTNAME "Config Restored"
|
|
--&ACTIONS { log, info }
|
|
--&MATCH { mgnt2TrapBoardNumber "$1"}
|
|
--&MESG "The Configuration of Board in Slot $1 has been restored ($A)"
|
|
DESCRIPTION "The Configuration has been restored from the management board"
|
|
::= { mgnt2Traps 6 }
|
|
|
|
mgnt2TrapGlobalPowerFail NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2AlmDef48b, mgnt2AlmDef48a}
|
|
STATUS current
|
|
--&FILTNAME "Power A Fail ON"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmDef48b "off", mgnt2AlmDef48a "on"}
|
|
--&MESG "Power Input A Fail on Chassis ($A)"
|
|
|
|
--&FILTNAME "Power B Fail ON"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmDef48b "on", mgnt2AlmDef48a "off"}
|
|
--&MESG "Power Input B Fail on Chassis ($A)"
|
|
|
|
--&FILTNAME "Power A and B Fail OFF"
|
|
--&ACTIONS { log, normal }
|
|
--&CLEARS { "Power A Fail ON", "Power B Fail ON"}
|
|
--&MATCH { mgnt2AlmDef48b "off", mgnt2AlmDef48a "off"}
|
|
--&MESG "Power Input A and B Present on Chassis ($A)"
|
|
|
|
DESCRIPTION "A global power supply failure has been detected"
|
|
::= { mgnt2Traps 8 }
|
|
|
|
mgnt2TrapFanPowerFail NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2AlmFanDefFuseB , mgnt2AlmFanDefFuseA, mgnt2AlmFanPwrFail1}
|
|
STATUS current
|
|
--&FILTNAME "FAN Fuse A Fail ON"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmFanDefFuseB "off", mgnt2AlmFanDefFuseA "on", mgnt2AlmFanPwrFail1 "*"}
|
|
--&MESG "Power Input A Fail on FAN ($A)"
|
|
|
|
--&FILTNAME "FAN Fuse B Fail ON"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmFanDefFuseB "on", mgnt2AlmFanDefFuseA "off", mgnt2AlmFanPwrFail1 "*"}
|
|
--&MESG "Power Input B Fail on FAN ($A)"
|
|
|
|
--&FILTNAME "FAN Fuse A and B Fail ON"
|
|
--&ACTIONS { log, critical }
|
|
--&MATCH { mgnt2AlmFanDefFuseB "on", mgnt2AlmFanDefFuseA "on", mgnt2AlmFanPwrFail1 "*"}
|
|
--&MESG "Power Input A and B Fail on FAN ($A)"
|
|
|
|
--&FILTNAME "FAN Fuse A and B Fail OFF"
|
|
--&ACTIONS { log, normal }
|
|
--&CLEARS { "FAN Fuse A Fail ON", "FAN Fuse B Fail ON", "FAN Fuse A and B Fail ON"}
|
|
--&MATCH { mgnt2AlmFanDefFuseB "off", mgnt2AlmFanDefFuseA "off", mgnt2AlmFanPwrFail1 "off"}
|
|
--&MESG "Power Input A and B Present on FAN ($A)"
|
|
|
|
--&FILTNAME "FAN Power Fail"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmFanDefFuseB "off", mgnt2AlmFanDefFuseA "off", mgnt2AlmFanPwrFail1 "on"}
|
|
--&MESG "Power Converter Fail on FAN ($A)"
|
|
|
|
DESCRIPTION "A Fan power supply failure has been detected"
|
|
::= { mgnt2Traps 9 }
|
|
|
|
mgnt2TrapGigmPowerFail NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2AlmMgntDefFuseA, mgnt2AlmMgntDefFuseB}
|
|
STATUS current
|
|
--&FILTNAME "Fuse B Fail ON"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmMgntDefFuseA "off", mgnt2AlmMgntDefFuseB "on"}
|
|
--&MESG "Power Input B Fail on MGNT ($A)"
|
|
|
|
--&FILTNAME "Fuse A Fail ON"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmMgntDefFuseA "on", mgnt2AlmMgntDefFuseB "off"}
|
|
--&MESG "Power Input A Fail on MGNT ($A)"
|
|
|
|
--&FILTNAME "Fuse A and B Fail OFF"
|
|
--&ACTIONS { log, normal }
|
|
--&CLEARS { "Fuse B Fail ON", "Fuse A Fail ON"}
|
|
--&MATCH { mgnt2AlmMgntDefFuseA "off", mgnt2AlmMgntDefFuseB "off"}
|
|
--&MESG "Power Input A and B Present on MGNT ($A)"
|
|
|
|
DESCRIPTION "A power supply default has been detected in the management board"
|
|
::= { mgnt2Traps 10 }
|
|
|
|
mgnt2TrapFanFail NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2AlmPbFan1Fail, mgnt2AlmPbFan2Fail, mgnt2AlmPbFan3Fail, mgnt2AlmPbFan4Fail, mgnt2AlmPbFan5Fail, mgnt2AlmPbFan6Fail}
|
|
STATUS current
|
|
--&FILTNAME "All trap Fail"
|
|
--&ACTIONS { log, critical }
|
|
--&MATCH { mgnt2AlmPbFan1Fail "on", mgnt2AlmPbFan2Fail "on", mgnt2AlmPbFan3Fail "on", mgnt2AlmPbFan4Fail "on", mgnt2AlmPbFan5Fail "on", mgnt2AlmPbFan6Fail "on"}
|
|
--&MESG "The FAN tray is in Failure condition (all FAN fail) ($A)"
|
|
|
|
--&FILTNAME "FAN 1 Fail"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmPbFan1Fail "on", mgnt2AlmPbFan2Fail "*", mgnt2AlmPbFan3Fail "*", mgnt2AlmPbFan4Fail "*", mgnt2AlmPbFan5Fail "*", mgnt2AlmPbFan6Fail "*"}
|
|
--&MESG "Fan number 1 Fail on FAN Module ($A)"
|
|
|
|
--&FILTNAME "FAN 2 Fail"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmPbFan1Fail "*", mgnt2AlmPbFan2Fail "on", mgnt2AlmPbFan3Fail "*", mgnt2AlmPbFan4Fail "*", mgnt2AlmPbFan5Fail "*", mgnt2AlmPbFan6Fail "*"}
|
|
--&MESG "Fan number 2 Fail on FAN Module ($A)"
|
|
|
|
--&FILTNAME "FAN 3 Fail"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmPbFan1Fail "*", mgnt2AlmPbFan2Fail "*", mgnt2AlmPbFan3Fail "on", mgnt2AlmPbFan4Fail "*", mgnt2AlmPbFan5Fail "*", mgnt2AlmPbFan6Fail "*"}
|
|
--&MESG "Fan number 3 Fail on FAN Module ($A)"
|
|
|
|
--&FILTNAME "FAN 4 Fail"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmPbFan1Fail "*", mgnt2AlmPbFan2Fail "*", mgnt2AlmPbFan3Fail "*", mgnt2AlmPbFan4Fail "on", mgnt2AlmPbFan5Fail "*", mgnt2AlmPbFan6Fail "*"}
|
|
--&MESG "Fan number 4 Fail on FAN Module ($A)"
|
|
|
|
--&FILTNAME "FAN 5 Fail"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmPbFan1Fail "*", mgnt2AlmPbFan2Fail "*", mgnt2AlmPbFan3Fail "*", mgnt2AlmPbFan4Fail "*", mgnt2AlmPbFan5Fail "on", mgnt2AlmPbFan6Fail "*"}
|
|
--&MESG "Fan number 5 Fail on FAN Module ($A)"
|
|
|
|
--&FILTNAME "FAN 6 Fail"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmPbFan1Fail "*", mgnt2AlmPbFan2Fail "*", mgnt2AlmPbFan3Fail "*", mgnt2AlmPbFan4Fail "*", mgnt2AlmPbFan5Fail "*", mgnt2AlmPbFan6Fail "on"}
|
|
--&MESG "Fan number 6 Fail on FAN Module ($A)"
|
|
|
|
--&FILTNAME "FAN Fail OFF"
|
|
--&ACTIONS { log, normal }
|
|
--&CLEARS { "All trap Fail"}
|
|
--&MATCH { mgnt2AlmPbFan1Fail "off", mgnt2AlmPbFan2Fail "off", mgnt2AlmPbFan3Fail "off", mgnt2AlmPbFan4Fail "off", mgnt2AlmPbFan5Fail "off", mgnt2AlmPbFan6Fail "off"}
|
|
--&MESG "The FAN tray is fully operational (no FAN fail)"
|
|
|
|
DESCRIPTION "A Fan failure has been detected"
|
|
::= { mgnt2Traps 11 }
|
|
|
|
mgnt2TrapLogFileFull NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2TrapBoardNumber, mgnt2AlmLog80Full, mgnt2AlmLogFileFull}
|
|
STATUS current
|
|
--&FILTNAME "Log almost full"
|
|
--&ACTIONS { log, warning }
|
|
--&MATCH { mgnt2TrapBoardNumber "$1", mgnt2AlmLog80Full "on", mgnt2AlmLogFileFull "off"}
|
|
--&MESG "The log of Board in slot $1 is 80% full ($A)"
|
|
|
|
--&FILTNAME "Log Full"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2TrapBoardNumber "$1", mgnt2AlmLog80Full "*", mgnt2AlmLogFileFull "on"}
|
|
--&MESG "The log of Board in slot $1 is Full ($A)"
|
|
DESCRIPTION "Indicates that the corresponding log file is almost full"
|
|
::= { mgnt2Traps 20 }
|
|
|
|
mgnt2TrapAlarm NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2TrapSeverity, mgnt2TrapSourcePm, mgnt2TrapBoardNumber, mgnt2TrapSourcePortType, mgnt2TrapSourcePortNumber, mgnt2TrapSourceLabel, mgnt2TrapSourceValue, mgnt2TrapNodeControllerIpAddress,mgnt2TrapChassisId}
|
|
STATUS current
|
|
--&FILTNAME "critical clear"
|
|
--&ACTIONS { log, normal }
|
|
--&CLEARS { "critical detect" }
|
|
--&MATCH { mgnt2TrapSeverity "Critical", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "off" }
|
|
--&MESG "$1 Alarms ($6) cleared on $2 (Slot $3) on $4 ($A)"
|
|
|
|
--&FILTNAME "critical detect"
|
|
--&ACTIONS { log, critical }
|
|
--&MATCH { mgnt2TrapSeverity "Critical", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "on" }
|
|
--&MESG "$1 Alarms ($6) detected on $2 (Slot $3) on $4 ($A)"
|
|
|
|
--&FILTNAME "major clear"
|
|
--&ACTIONS { log, normal }
|
|
--&CLEARS { "major detect" }
|
|
--&MATCH { mgnt2TrapSeverity "Major", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "off" }
|
|
--&MESG "$1 Alarms ($6) cleared on $2 (Slot $3) on $4 ($A)"
|
|
|
|
--&FILTNAME "major detect"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2TrapSeverity "Major", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "on" }
|
|
--&MESG "$1 Alarms ($6) detected on $2 (Slot $3) on $4 ($A)"
|
|
|
|
--&FILTNAME "minor clear"
|
|
--&ACTIONS { log, normal }
|
|
--&CLEARS { "minor detect" }
|
|
--&MATCH { mgnt2TrapSeverity "Minor", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "off" }
|
|
--&MESG "$1 Alarms ($6) cleared on $2 (Slot $3) on $4 ($A)"
|
|
|
|
--&FILTNAME "minor detect"
|
|
--&ACTIONS { log, minor }
|
|
--&MATCH { mgnt2TrapSeverity "Minor", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "on" }
|
|
--&MESG "$1 Alarms ($6) detected on $2 (Slot $3) on $4 ($A)"
|
|
|
|
--&FILTNAME "warning clear"
|
|
--&ACTIONS { log, normal }
|
|
--&CLEARS { "warning detect" }
|
|
--&MATCH { mgnt2TrapSeverity "Warning", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "off" }
|
|
--&MESG "$1 Alarms ($6) cleared on $2 (Slot $3) on $4 ($A)"
|
|
|
|
--&FILTNAME "warning detect"
|
|
--&ACTIONS { log, minor }
|
|
--&MATCH { mgnt2TrapSeverity "Warning", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "on" }
|
|
--&MESG "$1 Alarms ($6) detected on $2 (Slot $3) on $4 ($A)"
|
|
|
|
--&FILTNAME "indeterminate clear"
|
|
--&ACTIONS { log, normal }
|
|
--&CLEARS { "indeterminate detect" }
|
|
--&MATCH { mgnt2TrapSeverity "Indeterminate", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "off" }
|
|
--&MESG "$1 Alarms ($6) cleared on $2 (Slot $3) on $4 ($A)"
|
|
|
|
--&FILTNAME "indeterminate detect"
|
|
--&ACTIONS { log, minor }
|
|
--&MATCH { mgnt2TrapSeverity "Indeterminate", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "on" }
|
|
--&MESG "$1 Alarms ($6) detected on $2 (Slot $3) on $4 ($A)"
|
|
DESCRIPTION "Indicates that an alarm state has changed"
|
|
::= { mgnt2Traps 30 }
|
|
|
|
mgnt2TrapEvent NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2TrapBoardNumber, mgnt2TrapEventLabel, mgnt2TrapNodeControllerIpAddress,mgnt2TrapChassisId}
|
|
STATUS current
|
|
--&FILTNAME "event"
|
|
--&ACTIONS { log, info }
|
|
--&CLEARS { "critical detect" }
|
|
--&MATCH {mgnt2TrapBoardNumber "$1", mgnt2TrapEventLabel "$2" }
|
|
--&MESG "$2 (Slot $1) ($A)"
|
|
DESCRIPTION "Indicates that an event has occured"
|
|
::= { mgnt2Traps 31 }
|
|
|
|
mgnt2TrapControl NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2TrapSourcePm, mgnt2TrapBoardNumber, mgnt2TrapSourcePortType, mgnt2TrapSourcePortNumber, mgnt2TrapSourceLabel, mgnt2TrapSourceValue, mgnt2TrapNodeControllerIpAddress,mgnt2TrapChassisId}
|
|
STATUS current
|
|
--&FILTNAME "control sent"
|
|
--&ACTIONS { log, info }
|
|
--&MATCH { mgnt2TrapSourcePm "$1", mgnt2TrapBoardNumber "$2", mgnt2TrapSourcePortType "$3", mgnt2TrapSourcePortNumber "$4", mgnt2TrapSourceLabel "$5" }
|
|
--&MESG "Controls ($5) has been set to $6 on $1 (Slot $2) on $3 ($A)"
|
|
|
|
DESCRIPTION "Indicates that a control has been set to the module"
|
|
::= { mgnt2Traps 32 }
|
|
|
|
mgnt2TrapConfig NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2TrapSourcePm, mgnt2TrapBoardNumber, mgnt2TrapSourcePortType, mgnt2TrapSourcePortNumber, mgnt2TrapSourceLabel, mgnt2TrapSourceValue, mgnt2TrapNodeControllerIpAddress,mgnt2TrapChassisId}
|
|
STATUS current
|
|
--&FILTNAME "config sent"
|
|
--&ACTIONS { log, info }
|
|
--&MATCH { mgnt2TrapSourcePm "$1", mgnt2TrapBoardNumber "$2", mgnt2TrapSourcePortType "$3", mgnt2TrapSourcePortNumber "$4", mgnt2TrapSourceLabel "$5"}
|
|
--&MESG "Config Word ($5) has been set to $6 on $1 (Slot $2) on $3 ($A)"
|
|
|
|
DESCRIPTION "Indicates that a config word has been changed"
|
|
::= { mgnt2Traps 33 }
|
|
|
|
|
|
|
|
|
|
|
|
|
|