mibs/MIBS/enterasys/CT-HSIMPHYS-MIB
2023-12-05 12:25:34 +01:00

344 lines
11 KiB
Plaintext

CT-HSIMPHYS-MIB DEFINITIONS ::= BEGIN
-- ct-hsimphys-mib.txt
-- Revision: 01.00.00
-- Part Number:
-- Date: July 21, 1998
-- Cabletron Systems, Inc.
-- 35 Industrial Way, P.O. Box 5005
-- Rochester, NH 03867-0505
-- (603) 332-9400
-- support@ctron.com
-- This module provides an enterprise-specific HSIM container MIB.
--
-- This module will be extended, as needed.
--
-- Cabletron Systems reserves the right to make changes in
-- specification and other information contained in this document
-- without prior notice. The reader should consult Cabletron Systems
-- to determine whether any such changes have been made.
--
-- In no event shall Cabletron Systems be liable for any incidental,
-- indirect, special, or consequential damages whatsoever (including
-- but not limited to lost profits) arising out of or related to this
-- document or the information contained in it, even if Cabletron
-- Systems has been advised of, known, or should have known, the
-- possibility of such damages.
--
-- Cabletron grants vendors, end-users, and other interested parties
-- a non-exclusive license to use this Specification in connection
-- with the management of Cabletron products.
-- Copyright March 98 Cabletron Systems
-- This MIB is intended to provide a central repository & link to all
-- information about the physical aspect of an HSIM. Physical info
-- includes items related to the HW inventory , BOOT, EPLD, and other
-- low level information. For the purposes of this MIB, no difference
-- is recognized between a permantly-installed "option card", such as
-- the onboard WAN interface on the HSIM-W65/75, and an actual WPIM.
IMPORTS
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM RFC1213-MIB
ctHSIMPhysMib
FROM CTRON-MIB-NAMES;
--================= HSIM Info ===================
hsimInfo OBJECT IDENTIFIER ::= { ctHSIMPhysMib 1 }
hsimBoardRev OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is the printed circuit board
revision level."
::= { hsimInfo 1 }
hsimBoardId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is the printed circuit board
idenitifer."
::= { hsimInfo 2 }
hsimEpldRev OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is the programmable
logic device revision level."
::= { hsimInfo 3 }
hsimEpldId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is the programmable
logic device identifier."
::= { hsimInfo 4 }
hsimFsbRev OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is the first stage
boot revision level."
::= { hsimInfo 5 }
hsimSsbRev OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is the second stage
boot revision level."
::= { hsimInfo 6 }
hsimFwRev OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is the HSIM firmware
revision level."
::= { hsimInfo 7 }
--=================== HSIM Peripheral MBus Info =====================
hsimPeripheralMBusInfo OBJECT IDENTIFIER
::= { hsimInfo 8 }
mBusNumberBoardsInstalled OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is number of MBus boards
installed in this unit."
::= { hsimPeripheralMBusInfo 1 }
mBusBoardTable OBJECT-TYPE
SYNTAX SEQUENCE OF MBusBoardEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of MBus boards present in this unit"
::= { hsimPeripheralMBusInfo 2 }
mBusBoardEntry OBJECT-TYPE
SYNTAX MBusBoardEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The value of this object is an MBus board that is
present in this unit"
INDEX { mBusBoardID }
::= { mBusBoardTable 1 }
MBusBoardEntry ::=
SEQUENCE {
mBusBoardID INTEGER,
mBusBoardEntryType INTEGER,
mBusBoardOIDPointer OBJECT IDENTIFIER
}
mBusBoardID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is an index that uniquely
identifies the physical MBus board within the system."
::= { mBusBoardEntry 1 }
mBusBoardEntryType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
cmm(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the type of MBus
board installed."
::= { mBusBoardEntry 2 }
mBusBoardOIDPointer OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object defines the start of a MIB that
can be used to determine more specific information about
the given MBus board."
::= { mBusBoardEntry 3 }
--=================== HSIM Peripheral WPIM Info =====================
hsimPeripheralWpimInfo OBJECT IDENTIFIER
::= { hsimInfo 9 }
wpimNumberBoardsInstalled OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is number of WPIM boards
installed in this unit."
::= { hsimPeripheralWpimInfo 1 }
wpimBoardTable OBJECT-TYPE
SYNTAX SEQUENCE OF WpimBoardEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of WPIM boards present in this unit"
::= { hsimPeripheralWpimInfo 2 }
wpimBoardEntry OBJECT-TYPE
SYNTAX WpimBoardEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The value of this object is a WPIM board that is
present in this unit"
INDEX { wpimBoardID }
::= { wpimBoardTable 1 }
WpimBoardEntry ::=
SEQUENCE {
wpimBoardID INTEGER,
wpimBoardEntryType OBJECT IDENTIFIER,
wpimBoardOIDPointer OBJECT IDENTIFIER
}
wpimBoardID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is an index that uniquely
identifies this WPIM board."
::= { wpimBoardEntry 1 }
wpimBoardEntryType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the type of WPIM
board installed. This is within the portWpim branch
of the namingTree (1.3.6.1.4.1.52.3.8.1.2.5)"
::= { wpimBoardEntry 2 }
wpimBoardOIDPointer OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object defines the start of a MIB that
can be used to determine more specific information about
the given WPIM board."
::= { wpimBoardEntry 3 }
--=================== HSIM Local HW Devices Info =====================
hsimLocalHwDevicesInfo OBJECT IDENTIFIER
::= { hsimInfo 10 }
localHwDevicesTable OBJECT-TYPE
SYNTAX SEQUENCE OF LocalHwDevicesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of specific hardware devices present in this unit"
::= { hsimLocalHwDevicesInfo 1 }
localHwDevicesEntry OBJECT-TYPE
SYNTAX LocalHwDevicesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The value of this object is a WPIM module that is
present in this unit"
INDEX { localHwDeviceID }
::= { localHwDevicesTable 1 }
LocalHwDevicesEntry ::=
SEQUENCE {
localHwDeviceID INTEGER,
localHwDeviceType INTEGER,
localHwDeviceOperStatus INTEGER,
localHwDeviceAdminStatus INTEGER
}
localHwDeviceID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object is an index that uniquely
identifies the assoicated local hardware device."
::= { localHwDevicesEntry 1 }
localHwDeviceType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
siemensMunich32(2),
mitelMT8985(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the type of local
hardware device. These local hardware devices are those
specific ICs unique to this HSIM such as Siemens
Munich32, or Mitel MT8985."
::= { localHwDevicesEntry 2 }
localHwDeviceOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1), -- ready to pass packets
down(2),
testing(3), -- in some test mode
unknown(4), -- status can not be determined
-- for some reason.
dormant(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object describes the current state of the device."
::= { localHwDevicesEntry 3 }
localHwDeviceAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1), -- ready execute
down(2),
testing(3) -- in some test mode
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used by the Network Management System to
request a change in the current state of the device."
::= { localHwDevicesEntry 4 }
END