-- MIB File: BROCADE-OPTICAL-MONITORING-MIB.mib
-- *********************************************************************
-- BROCADE-OPTICAL-MONITORING-MIB.mib: Extreme Optical Monitoring MIB
--
-- Copyright (c) 2018 Extreme Networks, Inc.
-- All rights reserved.
--
-- *********************************************************************
BROCADE-OPTICAL-MONITORING-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
DisplayString, TEXTUAL-CONVENTION
FROM SNMPv2-TC
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
ifIndex
FROM IF-MIB
bcsiModules
FROM Brocade-REG-MIB
;
brocadeOpticalMonitoringMIB MODULE-IDENTITY
LAST-UPDATED "201909230000Z" -- Sep 23, 2019
ORGANIZATION "Extreme Networks, Inc."
CONTACT-INFO
"Postal: Extreme Networks, Inc.
6480 Via Del Oro
San Jose, CA 95119 USA
Phone: +1 408 579-2800
E-mail: support@extremenetworks.com
WWW: http://www.extremenetworks.com"
DESCRIPTION
"This MIB module supports monitoring of port optics
for parameters like, temperature, Tx Power, Rx Power,
Tx Bias Current, etc.,."
REVISION "201909230000Z" -- Sep 23, 2019
DESCRIPTION
"Added bcsiIfMediaInfoTable"
REVISION "201805291200Z" -- May 29, 2018
DESCRIPTION
"Updated ORGANIZATION and CONTACT-INFO with Extreme Networks"
REVISION "201611230000Z"
DESCRIPTION
"Added support for bcsiOptMonInfoTable."
REVISION "201609280000Z"
DESCRIPTION
"Initial version of this MIB module."
::= { bcsiModules 8 }
bcsiOptMonNotifications OBJECT IDENTIFIER ::= { brocadeOpticalMonitoringMIB 0 }
bcsiOptMonObjects OBJECT IDENTIFIER ::= { brocadeOpticalMonitoringMIB 1 }
bcsiOptMonConformance OBJECT IDENTIFIER ::= { brocadeOpticalMonitoringMIB 2 }
-- Optical Parameters Table per lane for a 40G SR4 and LR4,
-- 100G LR4 and LR10 optics.
bcsiOptMonLaneTable OBJECT-TYPE
SYNTAX SEQUENCE OF BcsiOptMonLaneEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists the instrumented parameters of all
lanes within a 40G Optic of type SR4 and LR4,
100G optic of type LR4 and LR10. LR4 and SR4 have 4 lanes
per optic, LR10 has 10 lanes per optic."
REFERENCE
"ITU recommendations G.783, G.784, G.953"
::= { bcsiOptMonObjects 1 }
bcsiOptMonLaneEntry OBJECT-TYPE
SYNTAX BcsiOptMonLaneEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Only the ifIndices of optical interfaces
whose parameters need to be monitored will
be used to index this table."
INDEX { ifIndex, bcsiOptMonLaneNum }
::= { bcsiOptMonLaneTable 1 }
BcsiOptMonLaneEntry ::=
SEQUENCE {
bcsiOptMonLaneNum
Unsigned32,
bcsiOptMonLaneTemperature
SnmpAdminString,
bcsiOptMonLaneTxPowerStatus
INTEGER,
bcsiOptMonLaneTxPower
SnmpAdminString,
bcsiOptMonLaneTxPowerVal
Unsigned32,
bcsiOptMonLaneRxPowerStatus
INTEGER,
bcsiOptMonLaneRxPower
SnmpAdminString,
bcsiOptMonLaneRxPowerVal
Unsigned32,
bcsiOptMonLaneTxBiasCurrent
SnmpAdminString
}
bcsiOptMonLaneNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The lane number of this 40G or 100G optic.
LR4 and SR4 have 4 lanes per optic.
LR10 has 10 lanes per optic."
::= { bcsiOptMonLaneEntry 1 }
bcsiOptMonLaneTemperature OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the value of the transmitter laser
diode temperature for the lane in the interface. This
object indicates the health of the transmitter.
The format is xxx.yyyy C(elcius), followed by whether
the measured value is normal, high/low alarm or
high/low warning."
::= { bcsiOptMonLaneEntry 2 }
bcsiOptMonLaneTxPowerStatus OBJECT-TYPE
SYNTAX INTEGER {
notSupported(1),
notApplicable(2),
highAlarm(3),
highWarn(4),
normal(5),
lowWarn(6),
lowAlarm(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the status of the transmitter optical
signal power for the lane in the interface, indicating
whether this is normal or an alarm is present."
::= { bcsiOptMonLaneEntry 3 }
bcsiOptMonLaneTxPower OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the value of the transmitter optical
signal power for the lane in the interface, measured in
dBm, followed by whether this is a normal value, or
high/low warning or alarm."
::= { bcsiOptMonLaneEntry 4 }
bcsiOptMonLaneTxPowerVal OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microWatt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the value of the transmitter optical
signal power for the lane in the interface, measured in microWatt."
::= { bcsiOptMonLaneEntry 5 }
bcsiOptMonLaneRxPowerStatus OBJECT-TYPE
SYNTAX INTEGER {
notSupported(1),
notApplicable(2),
highAlarm(3),
highWarn(4),
normal(5),
lowWarn(6),
lowAlarm(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the status of the receiver optical signal power
for the lane in the interface, indicating whether this is normal or
an alarm is present."
::= { bcsiOptMonLaneEntry 6 }
bcsiOptMonLaneRxPower OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the value of the receiver optical
signal power for the lane in the interface, measured in
dBm, followed by whether this is a normal value, or
high/low warning or alarm."
::= { bcsiOptMonLaneEntry 7 }
bcsiOptMonLaneRxPowerVal OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microWatt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the value of the receiver optical signal power
for the lane in the interface, measured in microWatt."
::= { bcsiOptMonLaneEntry 8 }
bcsiOptMonLaneTxBiasCurrent OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tx Bias Current. It is measured in mA, and is followed
by whether this is a normal value, or high/low warning or
alarm."
::= { bcsiOptMonLaneEntry 9 }
-- Optical Table for module level optical parameters like Temperature, Tx Power,
-- Rx Power and Tx Bias Current.
bcsiOptMonInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF BcsiOptMonInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists the instrumented parameters of all
optical interfaces."
REFERENCE
"ITU recommendations G.783, G.784, G.953"
::= { bcsiOptMonObjects 2}
bcsiOptMonInfoEntry OBJECT-TYPE
SYNTAX BcsiOptMonInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Only the ifIndices of optical interfaces
whose parameters need to be monitored will
be used to index this table."
INDEX { ifIndex }
::= { bcsiOptMonInfoTable 1 }
BcsiOptMonInfoEntry ::=
SEQUENCE {
bcsiOptMonTemperature
DisplayString,
bcsiOptMonTxPowerStatus
INTEGER,
bcsiOptMonTxPower
SnmpAdminString,
bcsiOptMonTxPowerVal
Unsigned32,
bcsiOptMonRxPowerStatus
INTEGER,
bcsiOptMonRxPower
SnmpAdminString,
bcsiOptMonRxPowerVal
Unsigned32,
bcsiOptMonTxBiasCurrent
DisplayString
}
bcsiOptMonTemperature OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the value of the transmitter laser
diode temperature for the interface. This object
indicates the health of the transmitter.
The format is xxx.yyyy C(elcius), followed by whether
the measured value is normal, high/low alarm or
high/low warning.
For 100G and 40G optic, this returns the average
temperature for all lanes."
::= { bcsiOptMonInfoEntry 1 }
bcsiOptMonTxPowerStatus OBJECT-TYPE
SYNTAX INTEGER {
notSupported(1),
notApplicable(2),
highAlarm(3),
highWarn(4),
normal(5),
lowWarn(6),
lowAlarm(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the status of the transmit optical
signal power for the interface, indicating whether this is normal or an alarm is present."
::= { bcsiOptMonInfoEntry 2 }
bcsiOptMonTxPower OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the value of the transmitter optical
signal power for the interface, measured in dBm, followed
by whether this is a normal value, or high/low warning
or alarm. For 100G optic, this returns the aggregated
Tx Power for all lanes."
::= { bcsiOptMonInfoEntry 3 }
bcsiOptMonTxPowerVal OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microWatt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the value of the transmitter optical
signal power for the interface, measured in microWatt.
For 100G optic, this returns the aggregated
Tx Power for all lanes "
::= { bcsiOptMonInfoEntry 4 }
bcsiOptMonRxPowerStatus OBJECT-TYPE
SYNTAX INTEGER {
notSupported(1),
notApplicable(2),
highAlarm(3),
highWarn(4),
normal(5),
lowWarn(6),
lowAlarm(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the status of the receiver optical signal
power for the interface, indicating whether this is normal or an alarm is present."
::= { bcsiOptMonInfoEntry 5 }
bcsiOptMonRxPower OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the value of the receiver optical
signal power for the interface, measured in dBm, followed
by whether this is a normal value, or high/low warning
or alarm.
For 100G and 40G optic, this returns the aggregated
Rx Power for all lanes."
::= { bcsiOptMonInfoEntry 6 }
bcsiOptMonRxPowerVal OBJECT-TYPE
SYNTAX Unsigned32
UNITS "microWatt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the value of the receiver optical
signal power for the interface, measured in microWatt.
For 100G and 40G optic, this returns the aggregated
Rx Power for all lanes "
::= { bcsiOptMonInfoEntry 7 }
bcsiOptMonTxBiasCurrent OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tx Bias Current. It is measured in mA, and is followed
by whether this is a normal value, or high/low warning or
alarm.
For 100G and 40G optic, this returns the aggregated
Tx Bias Current for all lanes."
::= { bcsiOptMonInfoEntry 8 }
bcsiIfMediaInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF BcsiIfMediaInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists the information of the media device
(SFP/XFP/Copper) installed in the physical port.
Only the ifIndices of Ethernet ports those are associated
with the operational cards will be included in this table."
::= { bcsiOptMonObjects 3 }
bcsiIfMediaInfoEntry OBJECT-TYPE
SYNTAX BcsiIfMediaInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table. The ifIndices of ethernet interfaces
will be used to index this table."
INDEX { ifIndex }
::= { bcsiIfMediaInfoTable 1 }
BcsiIfMediaInfoEntry ::=
SEQUENCE {
bcsiIfMediaType
DisplayString,
bcsiIfMediaVendorName
DisplayString,
bcsiIfMediaVersion
DisplayString,
bcsiIfMediaPartNumber
DisplayString,
bcsiIfMediaSerialNumber
DisplayString
}
bcsiIfMediaType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"he type of the media installed in the physical port."
::= { bcsiIfMediaInfoEntry 1 }
bcsiIfMediaVendorName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The media vendor name, full name of the corporation."
::= { bcsiIfMediaInfoEntry 2 }
bcsiIfMediaVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The media vendor product version number."
::= { bcsiIfMediaInfoEntry 3 }
bcsiIfMediaPartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The media vendor part number."
::= { bcsiIfMediaInfoEntry 4 }
bcsiIfMediaSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor serial number of the media device."
::= { bcsiIfMediaInfoEntry 5 }
--
-- Conformance
--
bcsiOptMonCompliances OBJECT IDENTIFIER
::= { bcsiOptMonConformance 1 }
bcsiOptMonGroups OBJECT IDENTIFIER
::= { bcsiOptMonConformance 2 }
bcsiOptMonCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which
implement BROCADE-OPTICAL-MONITORING-MIB."
MODULE
MANDATORY-GROUPS { bcsiOptMonLaneMonGroup ,
bcsiOptMonInfoMonGroup,
bcsiIfMediaGroup
}
::= { bcsiOptMonCompliances 1 }
--
-- Units of Conformance
--
bcsiOptMonLaneMonGroup OBJECT-GROUP
OBJECTS {
bcsiOptMonLaneNum,
bcsiOptMonLaneTemperature,
bcsiOptMonLaneTxPowerStatus,
bcsiOptMonLaneTxPower,
bcsiOptMonLaneTxPowerVal,
bcsiOptMonLaneRxPowerStatus,
bcsiOptMonLaneRxPower,
bcsiOptMonLaneRxPowerVal,
bcsiOptMonLaneTxBiasCurrent
}
STATUS current
DESCRIPTION
"A collection of objects for Optical Lane Monitoring of interface optics."
::= { bcsiOptMonGroups 1 }
bcsiOptMonInfoMonGroup OBJECT-GROUP
OBJECTS {
bcsiOptMonTemperature,
bcsiOptMonTxPowerStatus,
bcsiOptMonTxPower,
bcsiOptMonTxPowerVal,
bcsiOptMonRxPowerStatus,
bcsiOptMonRxPower,
bcsiOptMonRxPowerVal,
bcsiOptMonTxBiasCurrent
}
STATUS current
DESCRIPTION
"A collection of objects for Optical Monitoring of interface optics."
::= { bcsiOptMonGroups 2 }
bcsiIfMediaGroup OBJECT-GROUP
OBJECTS {
bcsiIfMediaType,
bcsiIfMediaVendorName,
bcsiIfMediaVersion,
bcsiIfMediaPartNumber,
bcsiIfMediaSerialNumber
}
STATUS current
DESCRIPTION
"A collection of objects for monitoring media information of interfaces."
::= { bcsiOptMonGroups 3 }