HIMOINSAv14-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215
DisplayString
FROM RFC1213-MIB
Gauge, Counter, IpAddress
FROM RFC1155-SMI;
InterfaceIndex ::= INTEGER
himoinsa OBJECT IDENTIFIER ::= { enterprises 41809 }
measures OBJECT IDENTIFIER ::= { himoinsa 1 }
parameters OBJECT IDENTIFIER ::= { himoinsa 2 }
traps OBJECT IDENTIFIER ::= { himoinsa 3 }
mainsFreq OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 1 }
mainsVL12 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 2 }
mainsVL23 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 3 }
mainsVL13 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 4 }
mainsVL1N OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 5 }
mainsVL2N OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 6 }
mainsVL3N OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 7 }
genFreq OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 8 }
genVL12 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 9 }
genVL23 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 10 }
genVL13 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 11 }
genVL1N OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 12 }
genVL2N OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 13 }
genVL3N OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 14 }
ph1Amp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 15 }
ph2Amp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 16 }
ph3Amp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 17 }
flagsCurrent OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 18 }
pFCTotal OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 19 }
pFC1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 20 }
pFC2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 21 }
pFC3 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 22 }
realPow OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 23 }
appPow OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 24 }
reactivePow OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 25 }
speed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 26 }
fuelLevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 27 }
altenatorVolt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 28 }
batteryVolt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 29 }
waterTemp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 30 }
oilPress OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 31 }
oilTemp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 32 }
sensorDet OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 33 }
units OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 34 }
totalInstantPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 35 }
partialInstantPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 36 }
powerPerDay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 37 }
powerPerMonth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 38 }
powerPerYear OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 39 }
totalRunningTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 40 }
partialRunningTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 41 }
successfulStarts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 42 }
unsuccessfulStarts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 43 }
switchPanelCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 44 }
secondaryBatteryVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 45 }
status OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 46 }
alarmBitMapHigh OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 47 }
alarmBitMapLow OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 48 }
alarmBitMapHigh1 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 49 }
falloArranqueMeasure OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 50 }
nivelCombustibleMeasure OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 51 }
caidaGrupoMeasure OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 52 }
caidaRedMeasure OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 53 }
caidaGrupoConmMeasure OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measures 54 }
measuresConmTable OBJECT-TYPE
SYNTAX SEQUENCE OF MeasuresConmEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { measures 55 }
measuresConmEntry OBJECT-TYPE
SYNTAX MeasuresConmEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { measuresConmIndex }
::= { measuresConmTable 1 }
MeasuresConmEntry ::= SEQUENCE {
measuresConmIndex
InterfaceIndex,
mainsFreqConm
INTEGER,
mainsVL12Conm
INTEGER,
mainsVL23Conm
INTEGER,
mainsVL13Conm
INTEGER,
mainsVL1NConm
INTEGER,
mainsVL2NConm
INTEGER,
mainsVL3NConm
INTEGER,
genFreqConm
INTEGER,
genVL12Conm
INTEGER,
genVL23Conm
INTEGER,
genVL13Conm
INTEGER,
genVL1NConm
INTEGER,
genVL2NConm
INTEGER,
genVL3NConm
INTEGER,
ph1AmpConm
INTEGER,
ph2AmpConm
INTEGER,
ph3AmpConm
INTEGER,
flagsCurrentConm
Gauge,
pFCTotalConm
INTEGER,
pFC1Conm
INTEGER,
pFC2Conm
INTEGER,
pFC3Conm
INTEGER,
realPowConm
INTEGER,
appPowConm
INTEGER,
reactPowConm
INTEGER,
mainsControlType
INTEGER,
statusConm
Gauge,
alarmBitMapConm
Gauge
}
measuresConmIndex OBJECT-TYPE
SYNTAX InterfaceIndex
ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 1 }
mainsFreqConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 2 }
mainsVL12Conm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 3 }
mainsVL23Conm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 4 }
mainsVL13Conm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 5 }
mainsVL1NConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 6 }
mainsVL2NConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 7 }
mainsVL3NConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 8 }
genFreqConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 9 }
genVL12Conm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 10 }
genVL23Conm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 11 }
genVL13Conm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 12 }
genVL1NConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 13 }
genVL2NConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 14 }
genVL3NConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 15 }
ph1AmpConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 16 }
ph2AmpConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 17 }
ph3AmpConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 18 }
flagsCurrentConm OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 19 }
pFCTotalConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 20 }
pFC1Conm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 21 }
pFC2Conm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 22 }
pFC3Conm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 23 }
realPowConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 24 }
appPowConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 25 }
reactPowConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 26 }
mainsControlType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 27 }
statusConm OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 28 }
alarmBitMapConm OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { measuresConmEntry 29 }
startsCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 1 }
timeBetweenStarts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 2 }
startDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 3 }
preheatingTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 4 }
startupTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 5 }
loadActivationTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 6 }
nominalConditionTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 7 }
dplusActivationTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 8 }
eJP1ActivationDelayTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 9 }
mainsActivationDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 10 }
coolingTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 11 }
pEActivationTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 12 }
counterDetectionTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 13 }
maximumAlarmActivationTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 14 }
phaseNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 15 }
maxGensetVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 16 }
minGensetVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 17 }
maxGensetAsymetryValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 18 }
maxGensetFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 19 }
minGensetFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 20 }
maxGensetCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 21 }
shortCircuitDetection OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 22 }
gensetNominalPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 23 }
maxReversePower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 24 }
maxPickupSpeed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 25 }
minPickupSpeed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 26 }
maxMainsVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 27 }
minMainsVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 28 }
maxMainsFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 29 }
minMainsFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 30 }
minBatteryVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 31 }
transferPumpMinLevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 32 }
transferPumpMaxLevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 33 }
startingVoltageGensetSignal OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 34 }
startingVoltageAlternator OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 35 }
startingSpeed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 36 }
engineFlywheelTeeth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 37 }
fuelReserveLevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 38 }
lowOilPressure OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 39 }
highWaterTemperatureThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 40 }
lowEngineTemperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 41 }
minPreheatingTemp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 42 }
maxPreheatingTemp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 43 }
deviceIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 44 }
deviceMaskSubnet OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 45 }
deviceGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 46 }
managerAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 47 }
agentSNMPPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 48 }
managertrapsPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 49 }
reset OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 50 }
version OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
""
::= { parameters 51 }
gensetStartStop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 52 }
gensetMode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 53 }
mainsBreakerStatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 54 }
gensetBreakerStatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parameters 55 }
parametersConmTable OBJECT-TYPE
SYNTAX SEQUENCE OF ParametersConmEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { parameters 56 }
parametersConmEntry OBJECT-TYPE
SYNTAX ParametersConmEntry
ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { parametersConmIndex }
::= { parametersConmTable 1 }
ParametersConmEntry ::= SEQUENCE {
parametersConmIndex InterfaceIndex,
phaseNumberConm INTEGER,
maxGensetVoltageConm INTEGER,
minGensetVoltageConm INTEGER,
maxGensetAsymetryValueConm INTEGER,
maxGensetFrequencyConm INTEGER,
minGensetFrequencyConm INTEGER,
maxGensetCurrentConm INTEGER,
shortCircuitDetectionConm INTEGER,
gensetNominalPowerConm INTEGER,
maxReversePowerConm INTEGER,
maxPickupSpeedConm INTEGER,
minPickupSpeedConm INTEGER,
maxMainsVoltageConm INTEGER,
minMainsVoltageConm INTEGER,
maxMainsFrequencyConm INTEGER,
minMainsFrequencyConm INTEGER,
startingVoltageValueConm INTEGER
}
parametersConmIndex OBJECT-TYPE
SYNTAX InterfaceIndex
ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { parametersConmEntry 1 }
phaseNumberConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parametersConmEntry 2 }
maxGensetVoltageConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parametersConmEntry 3 }
minGensetVoltageConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parametersConmEntry 4 }
maxGensetAsymetryValueConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parametersConmEntry 5 }
maxGensetFrequencyConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parametersConmEntry 6 }
minGensetFrequencyConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parametersConmEntry 7 }
maxGensetCurrentConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parametersConmEntry 8 }
shortCircuitDetectionConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parametersConmEntry 9 }
gensetNominalPowerConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parametersConmEntry 10 }
maxReversePowerConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parametersConmEntry 11 }
maxPickupSpeedConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parametersConmEntry 12 }
minPickupSpeedConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parametersConmEntry 13 }
maxMainsVoltageConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parametersConmEntry 14 }
minMainsVoltageConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parametersConmEntry 15 }
maxMainsFrequencyConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parametersConmEntry 16 }
minMainsFrequencyConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parametersConmEntry 17 }
startingVoltageValueConm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION
""
::= { parametersConmEntry 18 }
alarmString OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { traps 1 }
falloArranque OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { traps 2 }
nivelCombustible OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { traps 4 }
caidaGrupo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { traps 6 }
caidaRed OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { traps 8 }
caidaGrupoConm OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { traps 10 }
END