mibs/MIBS/hp/CONFIG-MIB
2023-12-05 12:25:34 +01:00

2843 lines
116 KiB
Plaintext

-- HP Enterprise Switch Configuration MIB
CONFIG-MIB DEFINITIONS ::= BEGIN
IMPORTS
IpAddress
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215
dot1dStpPortState, dot1dStpPortDesignatedBridge,
dot1dStpPortDesignatedPort
FROM BRIDGE-MIB -- RFC-1493
DisplayString, RowStatus, MacAddress, TimeStamp
FROM SNMPv2-TC
HpSwitchPortType, ConfigStatus
FROM HP-ICF-TC
hpSwitch
FROM HP-ICF-OID
InetAddressType, InetAddress
FROM INET-ADDRESS-MIB;
-- type.
Timeout ::= INTEGER -- a STP timer in units of 1/100 seconds
-- Icf Switch Specific
hpConfig OBJECT IDENTIFIER ::= { hpSwitch 7 }
VlanID ::= INTEGER (1..65535)
-- ###########################################################
-- the hpConfig Group
-- This group contains switch configuration related variables.
-- ###########################################################
hpSwitchConfig OBJECT IDENTIFIER ::= { hpConfig 1 }
hpSwitchSystemConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 1 }
hpSwitchAutoReboot OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "If the value of this variable was set to yes(1),
booting will conditionally enable all application
modules-the spanning tree, IP and IPX etc.. Otherwise
every application module must be manually enabled
through Network Control Language Interpreter's ENABLE
command."
::= { hpSwitchSystemConfig 1 }
hpSwitchTimeZone OBJECT-TYPE
SYNTAX INTEGER (-720..840)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The number of minutes to the east of Greenwich Mean
Time(GMT). For a location west of GMT, use a negative
integer."
::= { hpSwitchSystemConfig 2 }
hpSwitchDaylightTimeRule OBJECT-TYPE
SYNTAX INTEGER {
none(1),
alaska(2),
canadaAndContinentalUS(3),
middleEuropeAndPortugal(4),
southernHemisphere(5),
westernEurop(6),
userDefined(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The daylight savings time rule for use by the
Internet's RFC 868 Time protocol."
::= { hpSwitchSystemConfig 3 }
hpSwitchDaylightBeginningMonth OBJECT-TYPE
SYNTAX INTEGER (1..12)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The month that daylight saving time starts if
DaylightTimeRule is set to userDefined."
::= { hpSwitchSystemConfig 4 }
hpSwitchDaylightBeginningDay OBJECT-TYPE
SYNTAX INTEGER (1..31)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The day of the month that daylight saving time
starts if DaylightTimeRule is set to userDefined."
::= { hpSwitchSystemConfig 5 }
hpSwitchDaylightEndingMonth OBJECT-TYPE
SYNTAX INTEGER (1..12)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The month that daylight saving time ends if
DaylightTimeRule is set to userDefined."
::= { hpSwitchSystemConfig 6 }
hpSwitchDaylightEndingDay OBJECT-TYPE
SYNTAX INTEGER (1..31)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The day of the month that daylight saving time emds
if DaylightTimeRule is set to userDefined."
::= { hpSwitchSystemConfig 7 }
hpSwitchSystemConfigStatus OBJECT-TYPE
SYNTAX ConfigStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "The configuration status of this group of objects.
If one or more variables in this group were
reconfigurated since last reboot and required reboot
to take effect, the value of this variable will be
set to notInService."
::= { hpSwitchSystemConfig 8 }
hpSwitchSystemPortLEDMode OBJECT-TYPE
SYNTAX INTEGER {
link-activity(1),
link-only(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The mode of the port LED can be either link/activity
(link for 3 seconds then activity thereafter) or
link-only."
::= { hpSwitchSystemConfig 9 }
hpSwitchControlUnknownIPMulticast OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "When enabled along with IGMP, any IP Multicast packets
that are not already controlled by IGMP will be
restricted to ports that have detected a multicast
router or ports configured to always forward IP
multicast. When set to disabled or when IGMP is
disabled, the unknown IP Multicast packets will be
flooded out all ports in the VLAN"
::= { hpSwitchSystemConfig 10 }
hpSwitchIgmpDelayedGroupFlushTimer OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION "This feature is disabled by default, which is indicated
by a timer value of 0 seconds. When IGMP is enabled and
the value of the Delayed Group Flush Timer is not zero,
traffic filters for any previously-joined IGMP groups
which no longer have active members will persist for
the number of seconds indicated by the timer. This has
the effect of dropping any additional unjoined traffic
for an empty group until the Delayed Group Flush Timer
expires, at which time the traffic filter is then
removed."
::= { hpSwitchSystemConfig 11 }
hpSwitchMaxFrameSize OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION "This is the value of the global jumbos max-frame-size
supported by the switch. The default value for this is
set to 9216, in order to make it compatible with
previous versions of software. This configuration does
not take a reboot to take effect."
::= { hpSwitchSystemConfig 12 }
hpSwitchIpMTU OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION "This is the value of the global jumbos IP MTU or L3 MTU
supported by the switch. The default value for this is
set to 9198, in order to make it compatible with
previous versions of software. This configuration does
not take a reboot to take effect."
::= { hpSwitchSystemConfig 13 }
hpSwitchConsoleConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 2 }
hpSwitchTelnetAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS obsolete
DESCRIPTION "The status of the console telnet operation."
::= { hpSwitchConsoleConfig 1 }
hpSwitchTerminalType OBJECT-TYPE
SYNTAX INTEGER {
vt100(2),
ansi(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "Terminal type of the console device."
::= { hpSwitchConsoleConfig 2 }
hpSwitchConsoleRefRate OBJECT-TYPE
SYNTAX INTEGER {
refRate1(1),
refRate3(3),
refRate5(5),
refRate10(10),
refRate20(20),
refRate30(30),
refRate45(45),
refRate(60)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The rate, in second per cycle, at which the display
of various switch measurements."
::= { hpSwitchConsoleConfig 3 }
hpSwitchDisplayedEvent OBJECT-TYPE
SYNTAX INTEGER {
none(1),
major(2),
notInfo(3),
all(4),
debug(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The type of event messages are automatically
displayed on the console."
::= { hpSwitchConsoleConfig 4 }
hpSwitchConsoleConfigStatus OBJECT-TYPE
SYNTAX ConfigStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "The configuration status of this group of objects.
If one or more variables in this group were
reconfigurated since last reboot and required reboot
to take effect, the value of this variable will be
set to notInService."
::= { hpSwitchConsoleConfig 5 }
hpSwitchPortConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 3 }
hpSwitchPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table that contains information about the current
port status in this device."
::= { hpSwitchPortConfig 1 }
hpSwitchPortEntry OBJECT-TYPE
SYNTAX HpSwitchPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Information about a specific port status in this
device."
INDEX { hpSwitchPortIndex }
::= { hpSwitchPortTable 1 }
HpSwitchPortEntry ::=
SEQUENCE {
hpSwitchPortIndex INTEGER,
hpSwitchPortType HpSwitchPortType,
hpSwitchPortDescr DisplayString,
hpSwitchPortAdminStatus INTEGER,
hpSwitchPortEtherMode INTEGER,
hpSwitchPortVgMode INTEGER,
hpSwitchPortLinkbeat INTEGER,
hpSwitchPortTrunkGroup INTEGER,
hpSwitchPortBcastLimit INTEGER,
hpSwitchPortFastEtherMode INTEGER,
hpSwitchPortFlowControl INTEGER,
-- hpSwitchPortBcastPktLimit INTEGER,
hpSwitchPortTrunkType INTEGER,
hpSwitchPortTrunkLACPStatus INTEGER,
hpSwitchPortMDIXStatus INTEGER,
hpSwitchPortAutoMDIX INTEGER
}
hpSwitchPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The ifIndex value which uniquely identifies a row in
the Interfaces Table."
::= { hpSwitchPortEntry 1 }
hpSwitchPortType OBJECT-TYPE
SYNTAX HpSwitchPortType
ACCESS read-only
STATUS mandatory
DESCRIPTION "The type of port."
::= { hpSwitchPortEntry 2 }
hpSwitchPortDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION "A textual string containing information about the
interface."
::= { hpSwitchPortEntry 3 }
hpSwitchPortAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS obsolete
DESCRIPTION "The desired state of the interface. This variable is
similar to the ifAdminStatus but instead of keeping
the operational status, this variable maintain the
desired state in the configuration data base."
::= { hpSwitchPortEntry 4 }
hpSwitchPortEtherMode OBJECT-TYPE
SYNTAX INTEGER {
half-duplex(1),
full-duplex(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The type of transmission on this port. This
variable is valid only if the hpSwitchPortType
was Ethernet."
::= { hpSwitchPortEntry 5 }
hpSwitchPortVgMode OBJECT-TYPE
SYNTAX INTEGER {
master(1),
endNode(2),
autoDetect(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The type of transmission on this port. This variable
is valid only if the hpSwitchPortType was VG."
::= { hpSwitchPortEntry 6 }
hpSwitchPortLinkbeat OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The linkbeat status of this port."
::= { hpSwitchPortEntry 7 }
hpSwitchPortTrunkGroup OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The trunk group this port belong to."
::= { hpSwitchPortEntry 8 }
hpSwitchPortBcastLimit OBJECT-TYPE
SYNTAX INTEGER (0..99)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The percentage of network bandwidth consumed by
broadcast traffic through this port. If the value of
this variable is 0, there will be no broadcast limit."
::= { hpSwitchPortEntry 9 }
hpSwitchPortFastEtherMode OBJECT-TYPE
SYNTAX INTEGER {
half-duplex-10Mbits(1),
half-duplex-100Mbits(2),
full-duplex-10Mbits(3),
full-duplex-100Mbits(4),
auto-neg(5),
full-duplex-1000Mbits(6),
auto-10Mbits(7),
auto-100Mbits(8),
auto-1000Mbits(9),
full-duplex-10Gbits(10),
auto-10-100Mbits(11)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The type of transmission on this port. This variable
is valid only if the hpSwitchPortType was Fast
Ethernet."
::= { hpSwitchPortEntry 10 }
hpSwitchPortFlowControl OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The Flow Control of this port."
::= { hpSwitchPortEntry 11}
-- hpSwitchPortBcastPktLimit OBJECT-TYPE
-- SYNTAX INTEGER (0..1500000)
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION "Network bandwidth in packets per second consumed
-- by broadcast traffic through this port. If the value
-- of this variable is 0, there will be no broadcast
-- limit."
-- ::= { hpSwitchPortEntry 12 }
hpSwitchPortTrunkType OBJECT-TYPE
SYNTAX INTEGER {
trunk(1),
fecAuto(2),
saTrunk(3),
lacpTrk(4),
none(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "Used in conjunction with hpSwitchPortTrunkGroup to
determine what type of trunk and which group it
belongs to. If hpSwitchPortTrunkGroup is set to 0,
trunking is disabled on the port and this variable
becomes a 'don't care'"
::= { hpSwitchPortEntry 13 }
hpSwitchPortTrunkLACPStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
active(2),
passive(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "Used in conjunction with hpSwitchPortTrunkType.
When the trunk is a LACP trunk, this variable defines
its administrative status"
::= { hpSwitchPortEntry 14 }
hpSwitchPortMDIXStatus OBJECT-TYPE
SYNTAX INTEGER {
not-applicable(1),
mdi(2),
mdix(3),
automdix(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Shows the MDI/MDIX setting for an RJ-45 port.
Returns a value of 'not-applicable' for all
ports except RJ-45 ports."
::= { hpSwitchPortEntry 15 }
hpSwitchPortAutoMDIX OBJECT-TYPE
SYNTAX INTEGER {
not-applicable(1),
mdi(2),
mdix(3),
automdix(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "Sets the MDI/MDIX value for an RJ-45 port.
Negates need for crossover cables. 'automdix',
'mdi', or 'mdix' may be set when the port
configuration is set to any auto-negotiation mode,
for example 'auto' or 'auto-100', or to any of the
fixed-configuration modes, for example '100-full'.
The MDI/MDIX value is maintained across port
configuration mode changes."
::= { hpSwitchPortEntry 16 }
hpSwitchPortConfigStatus OBJECT-TYPE
SYNTAX ConfigStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "The configuration status of this group of objects. If
one or more variables in this group were
reconfigured since last reboot and required reboot to
take effect, the value of this variable will be set to
notInService."
::= { hpSwitchPortConfig 2 }
hpSwitchIpxConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 4 }
hpSwitchIpxConfigStatus OBJECT-TYPE
SYNTAX ConfigStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "The status of the IPX configuration table."
::= { hpSwitchIpxConfig 2 }
hpSwitchIpConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 5 }
hpSwitchIpTimepAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
manual(1),
disable(2),
dhcp(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The operational status of the Time protocol."
::= { hpSwitchIpConfig 1 }
hpSwitchIpTimepServerAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS deprecated
DESCRIPTION "### deprecated ### The IP address of the Time server."
::= { hpSwitchIpConfig 2 }
hpSwitchIpTimepPollInterval OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The client poll interval of the Time server in
minutes."
::= { hpSwitchIpConfig 3 }
hpSwitchIpConfigStatus OBJECT-TYPE
SYNTAX ConfigStatus
ACCESS read-only
STATUS obsolete
DESCRIPTION "The configuration status of the Timep and IP
related objects."
::= { hpSwitchIpConfig 5 }
hpSwitchIpTftpMode OBJECT-TYPE
SYNTAX INTEGER {
secure(1),
unsecure(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The operational mode of the Tftp protocol."
::= { hpSwitchIpConfig 6 }
hpSwitchIpTimepInetServerAddrType OBJECT-TYPE
SYNTAX InetAddressType
ACCESS read-write
STATUS mandatory
DESCRIPTION "The IP address type of the Time server."
::= { hpSwitchIpConfig 7 }
hpSwitchIpTimepInetServerAddr OBJECT-TYPE
SYNTAX InetAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION "The IP address (of the Time server)to which this entry's
addressing information pertains.
hpSwitchIpTimepInetServerAddr is always interpreted within
the context of hpSwitchIpTimepInetServerAddrType."
::= { hpSwitchIpConfig 8 }
hpSwitchSerialLinkConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 6 }
hpSwitchSLinkBaudRate OBJECT-TYPE
SYNTAX INTEGER {
speedSense(1),
baudRate300(2),
baudRate600(3),
baudRate1200(4),
baudRate2400(5),
baudRate4800(6),
baudRate9600(7),
baudRate19200(8),
baudRate38400(9),
baudRate57600(10),
baudRate115200(11)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The rate of data transfer between the console and
the node. baudRate1 is speed sense."
::= { hpSwitchSerialLinkConfig 1 }
hpSwitchSLinkFlowCtrl OBJECT-TYPE
SYNTAX INTEGER {
none(1),
xonXoff(2),
robustXonXoff(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The flow-control mechanism between the console and
the switch."
::= { hpSwitchSerialLinkConfig 2 }
hpSwitchSLinkConnInactTime OBJECT-TYPE
SYNTAX INTEGER (0..120)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The number of minutes to wait after no character was
input to log out the console. Valid values are 0 (not
to log out of the console for inactivity) through 120
(two hours)."
::= { hpSwitchSerialLinkConfig 3 }
hpSwitchSLinkModemConnTime OBJECT-TYPE
SYNTAX INTEGER (0..300)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The number of seconds to wait for data mode and
clear to send and receiver ready signals after
asserting request to send and terminal ready signals.
Valid values are 0 (switch will wait forever for the
modem) through 300 (5 minutes)."
::= { hpSwitchSerialLinkConfig 4 }
hpSwitchSLinkModemLostRecvTime OBJECT-TYPE
SYNTAX INTEGER (0..5000)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The number of milliseconds the receiver ready signal
is allowed to drop before the switch will disconnect
the modem. Valid values are 0 (the switch will wait
forever) through 5000 (5 seconds)."
::= { hpSwitchSerialLinkConfig 5 }
hpSwitchSLinkModemDisConnTime OBJECT-TYPE
SYNTAX INTEGER (0..60)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The number of seconds to wait after the modem is
disconnected before allowing the modem to be
reconnected. Valid values are 0 (allow a connection
as soon as possible, the default) through 60 (1
minute)."
::= { hpSwitchSerialLinkConfig 6 }
hpSwitchSLinkParity OBJECT-TYPE
SYNTAX INTEGER {
parityNone(1),
parityOdd(2),
parityEven(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The type of parity to use between the console and
the node."
::= { hpSwitchSerialLinkConfig 7 }
hpSwitchSLinkCharBits OBJECT-TYPE
SYNTAX INTEGER {
char8Bits(1),
char7Bits(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The number of bits per character to use between
the console and the node."
::= { hpSwitchSerialLinkConfig 8 }
hpSwitchSLinkStopBits OBJECT-TYPE
SYNTAX INTEGER {
stop1Bits(1),
stop1andHalfBits(2),
stop2Bits(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The number of stop bots to use when communicating
between the console and the node."
::= { hpSwitchSerialLinkConfig 9 }
hpSwitchSLinkConfigStatus OBJECT-TYPE
SYNTAX ConfigStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "The configuration status of this group of objects.
If one or more variables in this group were
reconfigured since last reboot and required reboot
to take effect, the value of this variable will be
set to notInService."
::= { hpSwitchSerialLinkConfig 10 }
hpSwitchFilterConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 8 }
-- A sample of the traffic filter
-- type MacAddr ProType SrcPort PortMask
-- unicast MAC address X port # Bit Mask of ports
-- multicast MAC address X X Bit Mask of ports
-- port X X port # Bit Mask of ports
-- level 3 X protocol X Bit Mask of ports
hpSwitchFilterConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchFilterConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table that contains information about the
traffic filter configuration in this device."
::= { hpSwitchFilterConfig 1 }
hpSwitchFilterConfigEntry OBJECT-TYPE
SYNTAX HpSwitchFilterConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Information about a traffic filter configuration
in this device."
INDEX { hpSwitchFilterIndex }
::= { hpSwitchFilterConfigTable 1 }
HpSwitchFilterConfigEntry ::=
SEQUENCE {
hpSwitchFilterIndex INTEGER,
hpSwitchFilterType INTEGER,
hpSwitchFilterSrcPort INTEGER,
hpSwitchFilterMacAddr MacAddress,
hpSwitchFilterProtocolType INTEGER,
hpSwitchFilterPortMask OCTET STRING,
hpSwitchFilterEntryStatus RowStatus
}
hpSwitchFilterIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "An index that uniquely identifies a traffic filter
for which this entry contains information."
::= { hpSwitchFilterConfigEntry 1 }
hpSwitchFilterType OBJECT-TYPE
SYNTAX INTEGER {
multicast(1),
level-3(2),
port(3),
unicast(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The type of filter."
::= { hpSwitchFilterConfigEntry 2 }
hpSwitchFilterSrcPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION "This variable is required when a port filter or
unicast filter was configurated. It will be ignored
otherwise."
::= { hpSwitchFilterConfigEntry 3 }
hpSwitchFilterMacAddr OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION "This variable is valid only if a unicast or
multicast filter was defined. It will be ignored
otherwise."
::= { hpSwitchFilterConfigEntry 4 }
hpSwitchFilterProtocolType OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION "This variable is valid only if a level-3 filter
was defined. It will be ignored otherwise. This
variable will contain either a etherType (DIX
Ethernet) or SAP(IEEE 802) value of the level-3
protocol."
::= { hpSwitchFilterConfigEntry 5 }
hpSwitchFilterPortMask OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION "This variable specifies a group of ports whose
traffic will be filtered. Each octet within the value
of this object specifies a set of eight ports, with
the first octet specifying ports 1 through 8, the
second octet specifying ports 9 through 16, etc.
Within each octet, the most significant bit represents
the lowest numbered port, and the least significant bit
represents the highest numbered port. Thus, each port
of the switch is represented by a single bit within
the value of this object."
::= { hpSwitchFilterConfigEntry 6 }
hpSwitchFilterEntryStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION "The status of a filter entry."
::= { hpSwitchFilterConfigEntry 7 }
hpSwitchProbeConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 9 }
hpSwitchProbeType OBJECT-TYPE
SYNTAX INTEGER {
ports(1),
vlan(2)
}
ACCESS read-write
STATUS obsolete
DESCRIPTION "If the value of this variable is equal to 1, the
probe will monitor those ports specified by
hpSwitchProbedPortMask, otherwise all of the port
belong to the virtual LAN specified by
hpSwitchProbedVlanId will be monitored."
::= { hpSwitchProbeConfig 1 }
hpSwitchProbedVlanId OBJECT-TYPE
SYNTAX VlanID
ACCESS read-write
STATUS obsolete
DESCRIPTION "The probed virtual LAN."
::= { hpSwitchProbeConfig 2 }
hpSwitchProbePort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS obsolete
DESCRIPTION "The port that every packet passes through those
probed ports will be copied to."
::= { hpSwitchProbeConfig 3 }
hpSwitchProbeAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS obsolete
DESCRIPTION "The operational status of the probing function"
::= { hpSwitchProbeConfig 4 }
hpSwitchProbedPortMask OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS obsolete
DESCRIPTION "This variable specifies a group of ports which will
be probed. Each octet within the value of this
object specifies a set of eight ports, with the
first octet specifying ports 1 through 8, the second
octet specifying ports 9 through 16, etc. Within each
octet, the most significant bit represents the lowest
numbered port, and the least significant bit
represents the highest numbered port. Thus, each port
of the switch is represented by a single bit within
the value of this object."
::= { hpSwitchProbeConfig 5 }
-- The FDDI IP Fragmention Configuration group
hpSwitchFddiIpFragConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 11 }
-- The FDDI IP Fragmention Configuration Table
hpSwitchFddiIpFragConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchFddiIpFragConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A list of IP fragmentation configuration
parameters for the FDDI cards in the switch."
::= { hpSwitchFddiIpFragConfig 1 }
hpSwitchFddiIpFragConfigEntry OBJECT-TYPE
SYNTAX HpSwitchFddiIpFragConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An Fddi IP fragmentation entry which is
containing configurable options for the FDDI
cards in the switch."
INDEX { hpSwitchFddiIpFragConfigIndex }
::= { hpSwitchFddiIpFragConfigTable 1 }
HpSwitchFddiIpFragConfigEntry ::=
SEQUENCE {
hpSwitchFddiIpFragConfigIndex INTEGER,
hpSwitchFddiIpFragConfigStatus INTEGER
}
hpSwitchFddiIpFragConfigIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each FDDI Card.
The value for each FDDI card must remain constant
at least from one re-initialization of the entity's
network management system to the next
re-initialization."
::= { hpSwitchFddiIpFragConfigEntry 1 }
hpSwitchFddiIpFragConfigStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The operational status of FDDI IP fragmentation
for each FDDI card.
enable(1): FDDI card will fragment all packets which
are bigger then the Ethernet packet size
limitation, 1518 Bytes.
disable(2): FDDI card will drop all packets which
are bigger then the Ethernet packet size
limitation, 1518 Bytes."
::= { hpSwitchFddiIpFragConfigEntry 2 }
hpSwitchABCConfig OBJECT IDENTIFIER ::= {hpSwitchConfig 12 }
hpSwitchABCConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchABCConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A list of Automatic Broadcast Control (ABC
disable/enable entries for each VLAN on the switch."
::= { hpSwitchABCConfig 1 }
hpSwitchABCConfigEntry OBJECT-TYPE
SYNTAX HpSwitchABCConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Contains the ABC status for each VLAN on the switch,
including IP RIP control and IPX RIP/SAP control."
INDEX { hpSwitchABCConfigVlan }
::= { hpSwitchABCConfigTable 1 }
HpSwitchABCConfigEntry ::=
SEQUENCE {
hpSwitchABCConfigVlan VlanID,
hpSwitchABCConfigControl INTEGER,
hpSwitchABCConfigIpRipControl INTEGER,
hpSwitchABCConfigIpxRipSapControl INTEGER,
hpSwitchABCConfigVlanBcastLimit INTEGER,
-- hpSwitchABCConfigVlanBcastPktLimit INTEGER,
hpSwitchABCConfigAutoGatewayConfig INTEGER
}
hpSwitchABCConfigVlan OBJECT-TYPE
SYNTAX VlanID
ACCESS read-only
STATUS mandatory
DESCRIPTION "The user is able to enable/disable ABC on a per VLAN
basis, so the VLAN serves as an index into the ABC
configuration table."
::= { hpSwitchABCConfigEntry 1 }
hpSwitchABCConfigControl OBJECT-TYPE
SYNTAX INTEGER {
ipipx(1),
ip(2),
ipx(3),
disable(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "ABC control is either IP&IPX or IP or IPX or disabled
for each VLAN on the switch."
::= { hpSwitchABCConfigEntry 2 }
hpSwitchABCConfigIpRipControl OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "IP RIP control. If this feature is enabled then IP
RIP packets will only be forwarded on ports, within
its VLAN domain, that have heard RIPs before. If
this feature is disabled then IP RIP packets seen by
a given port will be forwarded to all ports within its
VLAN domain."
::= { hpSwitchABCConfigEntry 3 }
hpSwitchABCConfigIpxRipSapControl OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "IPX RIP/SAP control. If this feature is enabled then
IPX RIP/SAP packets will only be forwarded on ports,
within its VLAN domain, that have previously seen
RIP/SAP packets. If this feature is disabled then
IPX RIP and SAP packets seen by a given port will be
forwarded to all ports within its VLAN domain."
::= { hpSwitchABCConfigEntry 4 }
hpSwitchABCConfigVlanBcastLimit OBJECT-TYPE
SYNTAX INTEGER (0..99)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The percentage of network bandwidth consumed by
broadcast traffic through VLAN. If the value of this
variable is 0, there will be no broadcast limit. There
is a default value chosen when ABC is enabled."
::= { hpSwitchABCConfigEntry 5 }
-- hpSwitchABCConfigVlanBcastPktLimit OBJECT-TYPE
-- SYNTAX INTEGER (0..2147483647)
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION "Network bandwidth in packets per second consumed
-- by broadcast traffic through VLAN. If the value of
-- this variable is 0, there will be no broadcast limit.
-- There is a default value chosen when ABC is enabled."
-- ::= { hpSwitchABCConfigEntry 6 }
hpSwitchABCConfigAutoGatewayConfig OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "If this feature is enabled then DHCP packets both
ucast and bcast with UDP destination port 68 will be
intercepted. DHCP packets with the router option in
the options field in the DHCP message will be
modified so that the first daddress in the router
option is the same as the clients address. Thus the
client will be its own default gateway. If this
feature is disabled DHCP packtes will be forwarded as
usual."
::= { hpSwitchABCConfigEntry 7 }
hpSwitchStpConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 14 }
hpSwitchStpVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchStpVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table that contains vlan-specific information
for the Spanning Tree Protocol."
::= { hpSwitchStpConfig 1}
hpSwitchStpVlanEntry OBJECT-TYPE
SYNTAX HpSwitchStpVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A list of information maintained by every port
about the Spanning Tree Protocol state for that
port."
INDEX { hpSwitchStpVlan }
::= { hpSwitchStpVlanTable 1 }
HpSwitchStpVlanEntry ::=
SEQUENCE {
hpSwitchStpVlan VlanID,
hpSwitchStpAdminStatus INTEGER,
hpSwitchStpPriority INTEGER,
hpSwitchStpMaxAge Timeout,
hpSwitchStpHelloTime Timeout,
hpSwitchStpForwardDelay Timeout
}
hpSwitchStpVlan OBJECT-TYPE
SYNTAX VlanID
ACCESS read-only
STATUS mandatory
DESCRIPTION "The operational status of the spanning tree
protocol."
::= { hpSwitchStpVlanEntry 1 }
hpSwitchStpAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The operational status of the spanning tree
protocol."
::= { hpSwitchStpVlanEntry 2 }
hpSwitchStpPriority OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The value of the write-able portion of the Bridge
ID, i.e., the first two octets of the (8 octet
long) Bridge ID. The other (last) 6 octets of the
Bridge ID are given by the value of
dot1dBaseBridgeAddress."
REFERENCE "IEEE 802.1D-1990: Section 4.5.3.7"
::= { hpSwitchStpVlanEntry 3 }
hpSwitchStpMaxAge OBJECT-TYPE
SYNTAX Timeout
ACCESS read-write
STATUS mandatory
DESCRIPTION "The maximum age of Spanning Tree Protocol
information learned from the network on any port
before it is discarded, in units of hundredths of
a second. This is the actual value that this
bridge is currently using."
REFERENCE "IEEE 802.1D-1990: Section 4.5.3.4"
::= { hpSwitchStpVlanEntry 4 }
hpSwitchStpHelloTime OBJECT-TYPE
SYNTAX Timeout
ACCESS read-write
STATUS mandatory
DESCRIPTION "The amount of time between the transmission of
Configuration bridge PDUs by this node on any port
when it is the root of the spanning tree or trying
to become so, in units of hundredths of a second.
This is the actual value that this bridge is
currently using."
REFERENCE "IEEE 802.1D-1990: Section 4.5.3.5"
::= { hpSwitchStpVlanEntry 5 }
hpSwitchStpForwardDelay OBJECT-TYPE
SYNTAX Timeout
ACCESS read-write
STATUS mandatory
DESCRIPTION "This time value, measured in units of hundredths
of a second, controls how fast a port changes its
spanning state when moving towards the Forwarding
state. The value determines how long the port
stays in each of the Listening and Learning
states, which precede the Forwarding state. This
value is also used, when a topology change has
been detected and is underway, to age all dynamic
entries in the Forwarding Database. [Note that
this value is the one that this bridge is
currently using, in contrast to
dot1dBridgeForwardDelay which is the value that
this bridge and all others would start using
if/when this bridge were to become the root.]"
REFERENCE "IEEE 802.1D-1990: Section 4.5.3.6"
::= { hpSwitchStpVlanEntry 6 }
hpSwitchStpPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchStpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table that contains port-specific information
for the Spanning Tree Protocol."
::= { hpSwitchStpConfig 2 }
hpSwitchStpPortEntry OBJECT-TYPE
SYNTAX HpSwitchStpPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A list of information maintained by every port
about the Spanning Tree Protocol state for that
port."
INDEX { hpSwitchStpPort }
::= { hpSwitchStpPortTable 1 }
HpSwitchStpPortEntry ::=
SEQUENCE {
hpSwitchStpPort INTEGER,
hpSwitchStpPortType HpSwitchPortType,
hpSwitchStpPortSrcMac MacAddress,
hpSwitchStpPortPriority INTEGER,
hpSwitchStpPortPathCost INTEGER,
hpSwitchStpPortMode INTEGER,
hpSwitchStpPortBpduFilter INTEGER,
hpSwitchStpPortBpduProtection INTEGER,
hpSwitchStpPortErrantBpduCounter Counter,
hpSwitchStpPortPvstFilter INTEGER,
hpSwitchStpPortPvstProtection INTEGER
}
hpSwitchStpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The port number of the port for which this entry
contains Spanning Tree Protocol management
information."
REFERENCE
"IEEE 802.1D-1990: Section 6.8.2.1.2"
::= { hpSwitchStpPortEntry 1 }
hpSwitchStpPortType OBJECT-TYPE
SYNTAX HpSwitchPortType
ACCESS read-only
STATUS mandatory
DESCRIPTION "The type of port."
::= { hpSwitchStpPortEntry 2 }
hpSwitchStpPortSrcMac OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION "The source MAC address used by the spanning
tree protocol."
::= { hpSwitchStpPortEntry 3 }
hpSwitchStpPortPriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The value of the priority field which is
contained in the first (in network byte order)
octet of the (2 octet long) Port ID. The other
octet of the Port ID is given by the value of
dot1dStpPort."
REFERENCE "IEEE 802.1D-1990: Section 4.5.5.1"
::= { hpSwitchStpPortEntry 4 }
hpSwitchStpPortPathCost OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The contribution of this port to the path cost of
paths towards the spanning tree root which include
this port. 802.1D-1990 recommends that the
default value of this parameter be in inverse
proportion to the speed of the attached LAN."
REFERENCE "IEEE 802.1D-1990: Section 4.5.5.3"
::= { hpSwitchStpPortEntry 5 }
hpSwitchStpPortMode OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
fast(2),
uplink(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "If the value of this variable is set to fast(2), the
port will go directly into the Forwarding State when a
device is connected to it. Use this feature only on
ports that are connected to an individual PC or
Workstation, to allow these ports to come up and
move quickly to the Forwarding State instead of going
through the normal STP initialization process.
Caution: Changing the value of this variable to fast(2)
on ports connected to a hub or switch may cause loops
in your network."
::= { hpSwitchStpPortEntry 6 }
hpSwitchStpPortBpduFilter OBJECT-TYPE
SYNTAX INTEGER {
true(1),
false(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Setting True will cause port to ignore ingress BPDUs
and not generate egress BPDUs, as the result the port
will stay in forwarding state. Default is False."
DEFVAL { false }
::= { hpSwitchStpPortEntry 7 }
hpSwitchStpPortBpduProtection OBJECT-TYPE
SYNTAX INTEGER {
true(1),
false(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Setting True indicates that no BPDUs are expected to
be received on this port. At the reception of BPDUs
the BPDU protection mechanism will disable this port
and port will transition into bpduError state.
Default is False."
DEFVAL { false }
::= { hpSwitchStpPortEntry 8 }
hpSwitchStpPortErrantBpduCounter OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS optional
DESCRIPTION "Counts the number of BPDUs that were not expected
to be received on this port. This counter gets
incremented only if hpSwitchStpPortBpduProtection,
hpSwitchStpPortBpduFilter, hpSwitchStpPortPvstFilter,
or hpSwitchStpPvstProtection is True for the port,
otherwise it is cleared to zero."
::= { hpSwitchStpPortEntry 9 }
hpSwitchStpPortPvstFilter OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-write
STATUS optional
DESCRIPTION "Setting True will cause the port to ignore incoming
PVST BPDUs.
Default is False."
DEFVAL { false }
::= { hpSwitchStpPortEntry 10 }
hpSwitchStpPortPvstProtection OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-write
STATUS optional
DESCRIPTION "Setting True indicates that any PVST BPDUs arriving
on this port should be discarded and that this will
cause the port to be disabled. The port will remain
disabled for the time period indicated by
hpSwitchStpBpduProtectionTimeout.
Default is False."
DEFVAL { false }
::= { hpSwitchStpPortEntry 11 }
hpSwitchStpTrapCntl OBJECT-TYPE
SYNTAX BITS {
errantBpdu(0)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Controls generation of SNMP traps by STP-enabled switch
for events defined in this MIB.
The set bit means 'enabled'.
- errantBpdu(0)
The state of this bit specifies whether the
notification trap allowed to be send when
unexpected (errant) BPDU is received on a port."
::= { hpSwitchStpConfig 3 }
hpSwitchStpBpduProtectionTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The duration of time in seconds when a protected port
affected by receiving of an unauthorized BPDU will
remain in down state. The zero value means infinity."
DEFVAL { 0 }
::= { hpSwitchStpConfig 4 }
hpSwitchIgmpConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 15 }
hpSwitchIgmpConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchIgmpConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table that contains information about the IGMP
Querier capacity or High Priority Forward
configuration on any given vlan on the switch."
::= { hpSwitchIgmpConfig 1 }
hpSwitchIgmpConfigEntry OBJECT-TYPE
SYNTAX HpSwitchIgmpConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "Information about the IGMP Querier feature associated
with a specific virtal LAN in this device."
INDEX { hpSwitchIgmpVlanIndex }
::= { hpSwitchIgmpConfigTable 1 }
HpSwitchIgmpConfigEntry ::=
SEQUENCE {
hpSwitchIgmpVlanIndex VlanID,
hpSwitchIgmpState INTEGER,
hpSwitchIgmpQuerierState INTEGER,
hpSwitchIgmpPriorityState INTEGER,
hpSwitchIgmpQuerierInterval INTEGER
}
hpSwitchIgmpVlanIndex OBJECT-TYPE
SYNTAX VlanID
ACCESS read-only
STATUS mandatory
DESCRIPTION "An index that uniquely identifies the IGMP
configuration of a virtual LAN for which this entry
contains information."
::= { hpSwitchIgmpConfigEntry 1 }
hpSwitchIgmpState OBJECT-TYPE
SYNTAX INTEGER{
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The operational status of the IGMP support for
this virtual LAN."
::= { hpSwitchIgmpConfigEntry 2 }
hpSwitchIgmpQuerierState OBJECT-TYPE
SYNTAX INTEGER{
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The operational status of the IGMP Querier
functionality for this virtual LAN."
::= { hpSwitchIgmpConfigEntry 3 }
hpSwitchIgmpPriorityState OBJECT-TYPE
SYNTAX INTEGER{
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The operational status of the IGMP Forward with High
Priority mode for this virtual LAN."
::= { hpSwitchIgmpConfigEntry 4 }
hpSwitchIgmpQuerierInterval OBJECT-TYPE
SYNTAX INTEGER (5..300)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The time (in seconds) to wait between Querier
election cycles for this virtual LAN."
::= { hpSwitchIgmpConfigEntry 5 }
hpSwitchIgmpPortConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchIgmpPortConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table that contains information about the IGMP port
configurations on this switch."
::= { hpSwitchIgmpConfig 2 }
hpSwitchIgmpPortConfigEntry OBJECT-TYPE
SYNTAX HpSwitchIgmpPortConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "The information associated with each IGMP port
configuration."
INDEX { hpSwitchIgmpPortIndex }
::= { hpSwitchIgmpPortConfigTable 1 }
HpSwitchIgmpPortConfigEntry ::=
SEQUENCE {
hpSwitchIgmpPortIndex INTEGER,
hpSwitchIgmpPortType HpSwitchPortType,
hpSwitchIgmpIpMcastState INTEGER
}
hpSwitchIgmpPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The ifIndex value which uniquely identifies a row in
the Interfaces Table."
::= { hpSwitchIgmpPortConfigEntry 1 }
hpSwitchIgmpPortType OBJECT-TYPE
SYNTAX HpSwitchPortType
ACCESS read-only
STATUS mandatory
DESCRIPTION "The type of port."
::= { hpSwitchIgmpPortConfigEntry 2 }
hpSwitchIgmpIpMcastState OBJECT-TYPE
SYNTAX INTEGER{
auto(1),
blocked(2),
forward(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The operational status of the IGMP feature for this
port or trunk. 1 implies that all IP Multicast
traffic will be monitored on the port, 2 implies that
IP Multicast traffic will be dropped on the port, and
3 implies that all IP Multicast traffic will be
forwarded without the switch examining it."
::= { hpSwitchIgmpPortConfigEntry 3 }
hpSwitchIgmpPortConfigTable2 OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchIgmpPortConfigEntry2
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table that contains information about the IGMP port
configurations on this switch. This table supercedes
hpSwitchIgmpPortConfigTable for products which support
multiple VLANs on each port."
::= { hpSwitchIgmpConfig 3 }
hpSwitchIgmpPortConfigEntry2 OBJECT-TYPE
SYNTAX HpSwitchIgmpPortConfigEntry2
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "The information associated with each IGMP port
configuration."
INDEX { hpSwitchIgmpPortVlanIndex2, hpSwitchIgmpPortIndex2 }
::= { hpSwitchIgmpPortConfigTable2 1 }
HpSwitchIgmpPortConfigEntry2 ::=
SEQUENCE {
hpSwitchIgmpPortVlanIndex2 INTEGER,
hpSwitchIgmpPortIndex2 INTEGER,
hpSwitchIgmpPortType2 HpSwitchPortType,
hpSwitchIgmpIpMcastState2 INTEGER,
hpSwitchIgmpPortForcedLeaveState INTEGER,
hpSwitchIgmpPortFastLeaveState INTEGER
}
hpSwitchIgmpPortVlanIndex2 OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The Vlan Index value which uniquely identifies a row
in the Interfaces Table."
::= { hpSwitchIgmpPortConfigEntry2 1 }
hpSwitchIgmpPortIndex2 OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The ifIndex value which uniquely identifies a row in
the Interfaces Table."
::= { hpSwitchIgmpPortConfigEntry2 2 }
hpSwitchIgmpPortType2 OBJECT-TYPE
SYNTAX HpSwitchPortType
ACCESS read-only
STATUS mandatory
DESCRIPTION "The type of port."
::= { hpSwitchIgmpPortConfigEntry2 3 }
hpSwitchIgmpIpMcastState2 OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
blocked(2),
forward(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The operational status of the IGMP feature for this
port or trunk. 1 implies that all IP Multicast traffic
will be monitored on the port, 2 implies that
IP Multicast traffic will be dropped on the port, and
3 implies that all IP Multicast traffic will be
forwarded without the switch examining it."
::= { hpSwitchIgmpPortConfigEntry2 4 }
hpSwitchIgmpPortForcedLeaveState OBJECT-TYPE
SYNTAX INTEGER{
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The operational status of the IGMP feature for this
port or trunk indicates whether any IGMP V2 Leaves
received for an IP Multicast group will cause the
group to be deleted after the
hpSwitchIgmpForcedLeaveInterval if no new IGMP V2
Reports are received for that group. Normal behavior
is for a group issuing a Leave to be deleted after
the Querier's Maximum Response time if no IGMP V2
Report is received."
::= { hpSwitchIgmpPortConfigEntry2 5 }
hpSwitchIgmpPortFastLeaveState OBJECT-TYPE
SYNTAX INTEGER{
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The operational status of the IGMP feature for this
port or trunk indicates whether any IGMP V2 Leaves
received for an IP Multicast group will cause the
group to be deleted immediately on single-
connection ports. Normal behavior is for a group
issuing a Leave to be deleted after the Querier's
Maximum Response time if no IGMP V2 Report is
received."
::= { hpSwitchIgmpPortConfigEntry2 6 }
hpSwitchIgmpForcedLeaveInterval OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION "When a port's hpSwitchIgmpPortForcedLeaveState is
enabled, this is the amount of time allowed for an
IGMP V2 Report to arrive and cancel deletion of a
multicast group requested by a previous IGMP V2
Leave request."
::= { hpSwitchIgmpConfig 4 }
-- CoS support MIB definition
hpSwitchCosConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 17 }
hpSwitchCosPortConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchCosPortConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table that contains information about the CoS port
configurations on this switch."
::= { hpSwitchCosConfig 1 }
hpSwitchCosPortConfigEntry OBJECT-TYPE
SYNTAX HpSwitchCosPortConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "The information associated with each CoS port
configuration."
INDEX { hpSwitchCosPortIndex }
::= { hpSwitchCosPortConfigTable 1 }
HpSwitchCosPortConfigEntry ::=
SEQUENCE {
hpSwitchCosPortIndex INTEGER,
hpSwitchCosPortType HpSwitchPortType,
hpSwitchCosPortPriority INTEGER,
hpSwitchCosPortDSCPPolicy INTEGER,
hpSwitchCosPortResolvedPriority INTEGER,
hpSwitchCosPortApplyPolicy INTEGER
}
hpSwitchCosPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The ifIndex value which uniquely identifies a row
in the Interfaces Table."
::= { hpSwitchCosPortConfigEntry 1 }
hpSwitchCosPortType OBJECT-TYPE
SYNTAX HpSwitchPortType
ACCESS read-only
STATUS deprecated
DESCRIPTION "The type of port."
::= { hpSwitchCosPortConfigEntry 2 }
hpSwitchCosPortPriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The 802.1p priority value to assign to packets
received on the specified port. This value will be
inserted in the 802.1Q tag and the packet will be
placed in the appropriate outbound port queue. The
value of 255 is used to indicate No Override."
::= { hpSwitchCosPortConfigEntry 3 }
hpSwitchCosPortDSCPPolicy OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The DSCP Policy to assign to packets received on
the specified Port. This is an index into the
hpSwitchCosDSCPPolicy table, or the value 255
indicating no DSCP Policy exists. This policy is
associated with an 802.1p priority value, which will
be inserted in the 802.1Q tag and will cause the
packet to be placed in the appropriate outbound port
queue. When the packet is IP protocol type, the DSCP
policy value (a Differentiated Services codepoint)
will also be written into the Differentiated-Services
field of the IP Type-of-Service byte."
::= { hpSwitchCosPortConfigEntry 4 }
hpSwitchCosPortResolvedPriority OBJECT-TYPE
SYNTAX INTEGER (0..7 | 255)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The 802.1p priority that will be applied to packets
received on the specified port. This value
represents the actual operating value for this CoS
port entry. A value of 255 represents no override
of the incoming priority."
::= { hpSwitchCosPortConfigEntry 5 }
hpSwitchCosPortApplyPolicy OBJECT-TYPE
SYNTAX INTEGER {
noPolicyOverride(1),
applyHpSwitchCosPortPriority(2),
applyHpSwitchCosPortDSCPPolicy(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "This object determines which configuration policy,
noPolicyOverride, hpSwitchCosPortPriority or
hpSwitchCosPortDSCPPolicy, applies for the given
Port CoS entry. These configuration policies are
mutually exclusive of one another."
::= { hpSwitchCosPortConfigEntry 6 }
hpSwitchCosVlanConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchCosVlanConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table that contains information about the CoS Vlan
configurations on this switch."
::= { hpSwitchCosConfig 2 }
hpSwitchCosVlanConfigEntry OBJECT-TYPE
SYNTAX HpSwitchCosVlanConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "The information associated with each CoS Vlan
configuration."
INDEX { hpSwitchCosVlanIndex }
::= { hpSwitchCosVlanConfigTable 1 }
HpSwitchCosVlanConfigEntry ::=
SEQUENCE {
hpSwitchCosVlanIndex VlanID,
hpSwitchCosVlanPriority INTEGER,
hpSwitchCosVlanDSCPPolicy INTEGER,
hpSwitchCosVlanResolvedPriority INTEGER,
hpSwitchCosVlanApplyPolicy INTEGER
}
hpSwitchCosVlanIndex OBJECT-TYPE
SYNTAX VlanID
ACCESS read-only
STATUS mandatory
DESCRIPTION "The index that uniquely identifies the CoS
configuration of a virtual LAN for which this entry
contains information."
::= { hpSwitchCosVlanConfigEntry 1 }
hpSwitchCosVlanPriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The 802.1p priority value to assign to packets
received on the specified Vlan. This value will be
inserted in the 802.1Q tag and the packet will be
placed in the appropriate outbound port queue. The
value of 255 is used to indicate No Override."
::= { hpSwitchCosVlanConfigEntry 2 }
hpSwitchCosVlanDSCPPolicy OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The DSCP Policy to assign to packets received on
the specified Vlan. This is an index into the
hpSwitchCosDSCPPolicy table, or the value 255
indicating no DSCP Policy exists. This policy is
associated with an 802.1p priority value, which
will be inserted in the 802.1Q tag and will cause
the packet to be placed in the appropriate outbound
port queue. When the packet is IP protocol type,
the DSCP policy value (a Differentiated Services
codepoint) will also be written into the
Differentiated-Services field of the IP
Type-of-Service byte."
::= { hpSwitchCosVlanConfigEntry 3 }
hpSwitchCosVlanResolvedPriority OBJECT-TYPE
SYNTAX INTEGER (0..7 | 255)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The 802.1p priority that will be applied to
packets received on the specified VLAN. This value
represents the actual operating value for this CoS
vlan entry. A value of 255 represents no override of
the incoming priority ."
::= { hpSwitchCosVlanConfigEntry 4 }
hpSwitchCosVlanApplyPolicy OBJECT-TYPE
SYNTAX INTEGER {
noPolicyOverride(1),
applyHpSwitchCosVlanPriority(2),
applyHpSwitchCosVlanDSCPPolicy(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "This object determines which configuration policy,
noPolicyOverride, hpSwitchCosVlanPriority or
hpSwitchCosDSCPPolicy, applies for this given Vlan
CoS entry. These configuration policies are mutually
exclusive of one another."
::= { hpSwitchCosVlanConfigEntry 5 }
hpSwitchCosProtocolConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchCosProtocolConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table that contains information about the CoS
protocol type configurations on this switch."
::= { hpSwitchCosConfig 3 }
hpSwitchCosProtocolConfigEntry OBJECT-TYPE
SYNTAX HpSwitchCosProtocolConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "The information associated with each CoS protocol
configuration."
INDEX { hpSwitchCosProtocolType }
::= { hpSwitchCosProtocolConfigTable 1 }
HpSwitchCosProtocolConfigEntry ::=
SEQUENCE {
hpSwitchCosProtocolType INTEGER,
hpSwitchCosProtocolPriority INTEGER
}
hpSwitchCosProtocolType OBJECT-TYPE
SYNTAX INTEGER {
ip(1),
ipx(2),
arp(3),
decnet(4),
appletalk(5),
sna(6),
netbios(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Packets with this protocol type will receive the new
priority value."
::= { hpSwitchCosProtocolConfigEntry 1 }
hpSwitchCosProtocolPriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The 802.1p priority value to assign to packets
received for the specified protocol. This value will
be inserted in the 802.1Q tag and the packet will be
placed in the appropriate outbound port queue. The
value of 255 is used to indicate No Override."
::= { hpSwitchCosProtocolConfigEntry 2 }
hpSwitchCosAddressConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchCosAddressConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table that contains information about the CoS
address configurations on this switch."
::= { hpSwitchCosConfig 4 }
hpSwitchCosAddressConfigEntry OBJECT-TYPE
SYNTAX HpSwitchCosAddressConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "The information associated with each CoS address
configuration."
INDEX { hpSwitchCosAddressIndex }
::= { hpSwitchCosAddressConfigTable 1 }
HpSwitchCosAddressConfigEntry ::=
SEQUENCE {
hpSwitchCosAddressIndex INTEGER,
hpSwitchCosAddressType INTEGER,
hpSwitchCosAddressIp IpAddress,
hpSwitchCosAddressPriority INTEGER,
hpSwitchCosAddressStatus RowStatus,
hpSwitchCosAddressDSCPPolicy INTEGER,
hpSwitchCosAddressResolvedPriority INTEGER,
hpSwitchCosAddressApplyPolicy INTEGER
}
hpSwitchCosAddressIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The index that uniquely identifies the CoS
configuration for an address for which this entry
contains information."
::= { hpSwitchCosAddressConfigEntry 1 }
hpSwitchCosAddressType OBJECT-TYPE
SYNTAX INTEGER {
ip(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The type of address to configure."
::= { hpSwitchCosAddressConfigEntry 2 }
hpSwitchCosAddressIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION "This variable is valid only if an IP CoS
configuration was defined. It will be ignored
otherwise. Packets with this IP address as a source
or destination will receive the new priority value."
::= { hpSwitchCosAddressConfigEntry 3 }
hpSwitchCosAddressPriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The 802.1p priority value to assign to packets
received for the specified address. This value will
be inserted in the 802.1Q tag and the packet will be
placed in the appropriate outbound port queue."
::= { hpSwitchCosAddressConfigEntry 4 }
hpSwitchCosAddressStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION "The status of a Cos Address entry."
::= { hpSwitchCosAddressConfigEntry 5 }
hpSwitchCosAddressDSCPPolicy OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The DSCP Policy to assign to packets received for
the specified address. This is an index into the
hpSwitchCosDSCPPolicy table, or the value 255
indicating no DSCP Policy exists. This policy is
associated with an 802.1p priority value, which
will be inserted in the 802.1Q tag and will cause
the packet to be placed in the appropriate outbound
port queue. The DSCP policy value (a Differentiated
Services codepoint) will also be written into the
Differentiated-Services field of the IP
Type-of-Service byte."
::= { hpSwitchCosAddressConfigEntry 6 }
hpSwitchCosAddressResolvedPriority OBJECT-TYPE
SYNTAX INTEGER (0..7 | 255)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The 802.1p priority that will be applied to packets
received for the specified address. This value
represents the actual operating value for this given
address entry. A value of 255 represents no override."
::= { hpSwitchCosAddressConfigEntry 7 }
hpSwitchCosAddressApplyPolicy OBJECT-TYPE
SYNTAX INTEGER {
applyHpSwitchCosAddressPriority(1),
applyHpSwitchCosAddressDSCPPolicy(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "This object determines which configuration policy,
hpSwitchCosAddressPriority or hpSwitchCosDSCPPolicy,
applies for the given Address CoS entry. These
configuration policies are mutually exclusive of
one another."
DEFVAL { applyHpSwitchCosAddressPriority }
::= { hpSwitchCosAddressConfigEntry 8 }
hpSwitchCosTosConfig OBJECT IDENTIFIER ::= { hpSwitchCosConfig 5 }
hpSwitchCosTosConfigMode OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
ipprecedence(2),
diffserv(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The operational status of Type of Service based
Class of Service."
::= { hpSwitchCosTosConfig 1 }
hpSwitchCosTosConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchCosTosConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table that contains information about the CoS Type
of Service configurations on this switch. This table
is used only when the hpSwitchCosTosConfigMode is set
to diffserv."
::= { hpSwitchCosTosConfig 2 }
hpSwitchCosTosConfigEntry OBJECT-TYPE
SYNTAX HpSwitchCosTosConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "The information associated with each CoS TOS
configuration."
INDEX { hpSwitchCosTosIndex }
::= { hpSwitchCosTosConfigTable 1 }
HpSwitchCosTosConfigEntry ::=
SEQUENCE {
hpSwitchCosTosIndex INTEGER,
hpSwitchCosTosPriority INTEGER,
hpSwitchCosTosDSCPPolicy INTEGER,
hpSwitchCosTosResolvedPriority INTEGER,
hpSwitchCosTosApplyPolicy INTEGER
}
hpSwitchCosTosIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "Packets with this value in the upper bits of the Type
of Service field of the IP protocol header will receive
the new priority value. For Differentiated Services
the upper 6 bits of the TOS field are used."
::= { hpSwitchCosTosConfigEntry 1 }
hpSwitchCosTosPriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS deprecated
DESCRIPTION "The 802.1p priority value to assign to packets
received for the specified TOS. This value will be
inserted in the 802.1Q tag and the packet will be
placed in the appropriate outbound port queue. The
value of 255 is used to indicate No Override."
::= { hpSwitchCosTosConfigEntry 2 }
hpSwitchCosTosDSCPPolicy OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The DSCP Policy to assign to packets received for
the specified ToS codepoint. This is an index
into the hpSwitchCosDSCPPolicy table, or the value
255 indicating no DSCP Policy exists. The DSCP
policy is associated with an 802.1p priority value,
which will be inserted in the 802.1Q tag and will
cause the packet to be placed in the appropriate
outbound port queue. The DSCP policy value (a
Differentiated Services codepoint) will also
replace the incoming value of the Differentiated
Services field of the IP Type-of-Service byte."
::= { hpSwitchCosTosConfigEntry 3 }
hpSwitchCosTosResolvedPriority OBJECT-TYPE
SYNTAX INTEGER (0..7 | 255)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The 802.1p priority that will be applied to
packets received for the specified ToS. This
value represents the actual operating value for
this given ToS entry. A value of 255 represents no
override of the incoming priority. If
hpSwitchCosTosApplyPolicy is set to
applyInheritedPriority, the parallel codepoint in
the hpSwitchCosDSCPPolicyConfigTable is used to
determine the operating priority. Otherwise if set
to applyHpSwitchCosTosDSCPPolicy, the priority for
the codepoint that the hpSwitchCosTosDSCPPolicy is
indexing will be used."
::= { hpSwitchCosTosConfigEntry 4 }
hpSwitchCosTosApplyPolicy OBJECT-TYPE
SYNTAX INTEGER {
applyInheritedPriority(1),
applyHpSwitchCosTosDSCPPolicy(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "This object determines which configuration policy,
applyInheritedPriority or hpSwitchCosTosDSCPPolicy,
applies for the given Tos CoS entry."
DEFVAL { applyInheritedPriority }
::= { hpSwitchCosTosConfigEntry 5 }
hpSwitchCosDSCPPolicyConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchCosDSCPPolicyConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table that contains information about the
priority applied to each of the Differentiated
Services Code Points."
::= { hpSwitchCosConfig 6 }
hpSwitchCosDSCPPolicyConfigEntry OBJECT-TYPE
SYNTAX HpSwitchCosDSCPPolicyConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A list of objects describing a DiffServe Codepoint
(DSCP), and the 802.1p priority to apply for that
DSCP."
INDEX { hpSwitchCosDSCPPolicyIndex }
::= { hpSwitchCosDSCPPolicyConfigTable 1 }
HpSwitchCosDSCPPolicyConfigEntry ::=
SEQUENCE {
hpSwitchCosDSCPPolicyIndex INTEGER,
hpSwitchCosDSCPPolicyPriority INTEGER,
hpSwitchCosDSCPPolicyName OCTET STRING
}
hpSwitchCosDSCPPolicyIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An index to uniquely identify each row in the
hpSwitchCosDSCPPolicyConfigTable."
::= { hpSwitchCosDSCPPolicyConfigEntry 1 }
hpSwitchCosDSCPPolicyPriority OBJECT-TYPE
SYNTAX INTEGER (0..7 | 255)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The 802.1p priority value to assign to packets
with a given DSCP. This value will be inserted in
the 802.1Q tag and the packet will be placed in the
appropriate outbound port queue. The value of 255
is used to indicate no override of the incoming
priority."
::= { hpSwitchCosDSCPPolicyConfigEntry 2 }
hpSwitchCosDSCPPolicyName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION "A user settable name describing a DSCP policy
table entry."
::= { hpSwitchCosDSCPPolicyConfigEntry 3 }
hpSwitchCosAppTypeConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchCosAppTypeConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table that contains information about the CoS
Application type configurations on the switch. An
application is determined by its network source
and/or destination port number."
::= { hpSwitchCosConfig 7 }
hpSwitchCosAppTypeConfigEntry OBJECT-TYPE
SYNTAX HpSwitchCosAppTypeConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in the switch
hpSwitchCosAppTypeConfigEntry Table."
INDEX { hpSwitchCosAppTypeConfigIndex }
::= { hpSwitchCosAppTypeConfigTable 1 }
HpSwitchCosAppTypeConfigEntry ::=
SEQUENCE {
hpSwitchCosAppTypeConfigIndex INTEGER,
hpSwitchCosAppTypeConfigType INTEGER,
hpSwitchCosAppTypeSrcPort INTEGER,
hpSwitchCosAppTypeDestPort INTEGER,
hpSwitchCosAppTypePriority INTEGER,
hpSwitchCosAppTypeDSCPPolicy INTEGER,
hpSwitchCosAppTypeResolvedPriority INTEGER,
hpSwitchCosAppTypeApplyPolicy INTEGER,
hpSwitchCosAppTypeStatus RowStatus,
hpSwitchCosAppTypeMaxSrcPort INTEGER,
hpSwitchCosAppTypeMaxDestPort INTEGER
}
hpSwitchCosAppTypeConfigIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An index to uniquely identify this
hpSwitchCosAppType row."
::= { hpSwitchCosAppTypeConfigEntry 1 }
hpSwitchCosAppTypeConfigType OBJECT-TYPE
SYNTAX INTEGER {
udpSrcPortConfig(1),
udpDestPortConfig(2),
udpBothPortsConfig(3),
tcpSrcPortConfig(4),
tcpDestPortConfig(5),
tcpBothPortsConfig(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "This signifies which network port number to apply
to the given CoS Application policy."
::= { hpSwitchCosAppTypeConfigEntry 2 }
hpSwitchCosAppTypeSrcPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION "This object represents the source network port
that this policy applies to."
::= { hpSwitchCosAppTypeConfigEntry 3 }
hpSwitchCosAppTypeDestPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION "This object represents the destination network
port that this policy applies to."
::= { hpSwitchCosAppTypeConfigEntry 4 }
hpSwitchCosAppTypePriority OBJECT-TYPE
SYNTAX INTEGER (0..7 | 255)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The 802.1p priority that should be applied to
packets containing the particular configured source
and/or destination port number in this entry. A
value of 255 represents that no priority override
should take place."
::= { hpSwitchCosAppTypeConfigEntry 5 }
hpSwitchCosAppTypeDSCPPolicy OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The DSCP Policy to assign to packets received for
the specified application. This is an index into
the hpSwitchCosDSCPPolicy table, or the value 255
indicating no DSCP Policy exists. This policy is
associated with an 802.1p priority value, which
will be inserted in the 802.1Q tag and will cause
the packet to be placed in the appropriate outbound
port queue. The DSCP policy value (a
Differentiated Services codepoint) will also be
written into the Differentiated-Services field of
the IP Type-of-Service byte. The value of 255 is
used to indicate No Override."
::= { hpSwitchCosAppTypeConfigEntry 6 }
hpSwitchCosAppTypeResolvedPriority OBJECT-TYPE
SYNTAX INTEGER (0..7 | 255)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The 802.1p priority that will be applied to
packets received on the specified application.
This value represents the actual operating value
for this CoS application entry. A value of 255
represents no override of the incoming priority"
::= { hpSwitchCosAppTypeConfigEntry 7 }
hpSwitchCosAppTypeApplyPolicy OBJECT-TYPE
SYNTAX INTEGER {
applyHpSwitchCosAppTypePriority(1),
applyHpSwitchCosAppTypeDSCPPolicy(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "This object determines which configuration policy,
hpSwitchCosAppTypePriority or
hpSwitchCosAppTypeDSCPPolicy, applies for the given
AppType CoS entry. These configuration policies
are mutually exclusive of one another."
DEFVAL { applyHpSwitchCosAppTypePriority }
::= { hpSwitchCosAppTypeConfigEntry 8 }
hpSwitchCosAppTypeStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION "This object is used to create and delete in the
hpSwitchCosAppType table."
::= { hpSwitchCosAppTypeConfigEntry 9 }
hpSwitchCosAppTypeMaxSrcPort OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION "This object represents the maximum source network
port that this policy applies to. If a single,
specific port is being used and not a range, then
value of this object is zero."
::= { hpSwitchCosAppTypeConfigEntry 10 }
hpSwitchCosAppTypeMaxDestPort OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION "This object represents the maximum destination
network port that this policy applies to. If a
single, specific port is being used and not a range,
then value of this object is zero."
::= { hpSwitchCosAppTypeConfigEntry 11 }
hpSwitchCosLastChange OBJECT-TYPE
SYNTAX TimeStamp
ACCESS read-only
STATUS mandatory
DESCRIPTION "The value of the agent's sysUptime when the last
time this device experienced a change in the
Class of Service configuration."
::= { hpSwitchCosConfig 8 }
hpSwitchConfigCosLastConfigError OBJECT-TYPE
SYNTAX INTEGER {
aclQosNoError(1),
aclQosTooManyRulesError(2),
aclQosTooManyMasksError(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The type of the last QoS
configuration result or error.
This object is updated for each
new QoS configuration. It is
reset upon reboot."
::= { hpSwitchCosConfig 9 }
hpSwitchMeshConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 18 }
hpSwitchMeshMulticastAgingMode OBJECT-TYPE
SYNTAX INTEGER {
aging(1),
nonaging(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION "With meshing active, a value of aging will cause
learned multicast addresses to be aged out within
the required address aging interval. A setting of
nonaging will prevent learned multicast addresses
from being removed from the switch. Multicast addresses
learned while in nonaging mode are not removed until
the switch is rebooted."
::= { hpSwitchMeshConfig 1 }
hpSwitchMeshBackwardCompatibility OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION "Due to some hardware differences, the Series
1600/24xx/4000/8000 switches cannot be used
directly in a mesh environment with Series 5300XL
switches. Series 5300XL switches need to emulate
the operation of Series 1600/24xx/4000/8000
switches in order to have a heterogeneous mesh
working properly. Meshing backward-compatibility
feature allows Series 5300XL switches to operate in
a compatible mode in which the operation of Series
1600/24xx/4000/8000 switches are emulated. When
backward-compatibility is enabled, meshing software
will establish connections with Series
1600/24xx/4000/8000 switches and emulate their
operation. When backward-compatibility disabled,
Series 1600/24xx/4000/8000 switches in the mesh
will be ignored by the Series 5300XL switches."
::= { hpSwitchMeshConfig 2 }
hpSwitchPortIsolationConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 19 }
hpSwitchPortIsolationMode OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "This enables the port isolation feature on the device.
Note: Enabling this feature may require VLANS to be
configured properly."
::= { hpSwitchPortIsolationConfig 1 }
hpSwitchPortIsolationConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchPortIsolationConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table that contains information about the CoS
Application type configurations on the switch. An
application is determined by its network source
and/or destination port number."
::= { hpSwitchPortIsolationConfig 2 }
hpSwitchPortIsolationConfigEntry OBJECT-TYPE
SYNTAX HpSwitchPortIsolationConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in the switch
hpSwitchPortIsolationConfigEntry Table."
INDEX { hpSwitchPortIsolationPort }
::= { hpSwitchPortIsolationConfigTable 1 }
HpSwitchPortIsolationConfigEntry ::=
SEQUENCE {
hpSwitchPortIsolationPort INTEGER,
hpSwitchPortIsolationPortMode INTEGER
}
hpSwitchPortIsolationPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in the IfIndex table representing a logical port
on this switch."
::= { hpSwitchPortIsolationConfigEntry 1 }
hpSwitchPortIsolationPortMode OBJECT-TYPE
SYNTAX INTEGER {
uplink(1),
public(2),
private(3),
local(4),
group1(5),
group2(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "Defines the operational mode of a port when Port
Isolation feature is enabled."
::= { hpSwitchPortIsolationConfigEntry 2 }
hpSwitchSshConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 20 }
hpSwitchSshAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The status of the SSH operation."
::= { hpSwitchSshConfig 1 }
hpSwitchSshVersion OBJECT-TYPE
SYNTAX INTEGER {
version1(1),
version2(2),
version1or2(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The version of the SSH protocol to run.
'version1' will accept connections from
v1.3 or v1.5 clients. 'version2' will accept
connections only from v2.0 clients.
The default is 'version1_or_2' which will accept any
connection which can be successfully negotiated."
DEFVAL { 1 }
::= { hpSwitchSshConfig 2 }
hpSwitchSshTimeout OBJECT-TYPE
SYNTAX Timeout (5..120)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The maximum length of time (in seconds) between the wakeup
of SSH task and successful protocol negotiation and
authentication. The default is 120 seconds."
DEFVAL { 120 }
::= { hpSwitchSshConfig 3 }
hpSwitchSshPortNumber OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION "The port number on which SSH daemon should listen for
connection requests."
DEFVAL { 22 }
::= { hpSwitchSshConfig 4 }
hpSwitchSshServerKeySize OBJECT-TYPE
SYNTAX INTEGER {
bits512(1),
bits768(2),
bits1024(3)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies the key size (in bits) of version 1 SSH host
rsa key"
::= { hpSwitchSshConfig 5 }
hpSwitchSshFileServerAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether or not the SSH daemon will accept
and process file transfer requests."
::= { hpSwitchSshConfig 6 }
hpSwitchSshIpVersion OBJECT-TYPE
SYNTAX INTEGER {
ipv4(1),
ipv6(2),
ipv4or6(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The types of IP connections SSH will support.
'ipv4' will accept connections from
Ipv4 clients. 'ipv6' will accept
connections only from ipv6 clients.
The default is 'ipv4or6' which will accept
Connections from both ipv4 and ipv6 clients."
DEFVAL { 3 }
::= { hpSwitchSshConfig 7 }
hpSwitchPendingConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 21 }
hpSwitchPendingConfigControl OBJECT-TYPE
SYNTAX INTEGER {
applyMstp(1),
resetMstp(2),
noAction(3)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION "The object controls switch pending configuration.
If set to the 'applyMstp' value the object applies
pending Multiple Spanning Tree Protocol (MSTP)
configuration. The 'resetMstp' value, if set, triggers
copying of the active MSTP configuration to the
pending one. Before the pending configuration is applied
its consistency is verified and the request fails if
errors are detected.
The value the object returns is undefined."
::= { hpSwitchPendingConfig 1 }
hpSwitchBWMinConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 22 }
hpSwitchBWMinEgressPortConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchBWMinEgressPortConfigEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION "New definitions under HP-ICF-RATE-LIMIT-MIB.
A table that contains information about the port's
egress Guaranteed Minimum Bandwidth configurations
on this switch."
::= { hpSwitchBWMinConfig 1 }
hpSwitchBWMinEgressPortConfigEntry OBJECT-TYPE
SYNTAX HpSwitchBWMinEgressPortConfigEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION "New definitions under HP-ICF-RATE-LIMIT-MIB.
The information associated with each port's egress
Guaranteed Minimum Bandwidth configuration."
INDEX { hpSwitchBWMinEgressPortIndex }
::= { hpSwitchBWMinEgressPortConfigTable 1 }
HpSwitchBWMinEgressPortConfigEntry ::=
SEQUENCE {
hpSwitchBWMinEgressPortIndex INTEGER,
hpSwitchBWMinEgressPortPrctLowPriority INTEGER,
hpSwitchBWMinEgressPortPrctNormalPriority INTEGER,
hpSwitchBWMinEgressPortPrctMedPriority INTEGER,
hpSwitchBWMinEgressPortPrctHighPriority INTEGER
}
hpSwitchBWMinEgressPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS deprecated
DESCRIPTION "New definitions under HP-ICF-RATE-LIMIT-MIB.
The ifIndex value which uniquely identifies a row
in the Interfaces Table."
::= { hpSwitchBWMinEgressPortConfigEntry 1 }
hpSwitchBWMinEgressPortPrctLowPriority OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS deprecated
DESCRIPTION "New definitions under HP-ICF-RATE-LIMIT-MIB.
The percentage of Guaranteed Minimum bandwidth to
be assigned to the egress Low-Priority queue for
this port. Total values for all four queues must not
exceed 100 percent."
::= { hpSwitchBWMinEgressPortConfigEntry 2 }
hpSwitchBWMinEgressPortPrctNormalPriority OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS deprecated
DESCRIPTION "New definitions under HP-ICF-RATE-LIMIT-MIB.
The percentage of Guaranteed Minimum bandwidth to
be assigned to the egress Normal-Priority queue for
this port. Total values for all four queues must not
exceed 100 percent."
::= { hpSwitchBWMinEgressPortConfigEntry 3 }
hpSwitchBWMinEgressPortPrctMedPriority OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS deprecated
DESCRIPTION "New definitions under HP-ICF-RATE-LIMIT-MIB.
The percentage of Guaranteed Minimum bandwidth to
be assigned to the egress Medium-Priority queue for
this port. Total values for all four queues must not
exceed 100 percent."
::= { hpSwitchBWMinEgressPortConfigEntry 4 }
hpSwitchBWMinEgressPortPrctHighPriority OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS deprecated
DESCRIPTION "New definitions under HP-ICF-RATE-LIMIT-MIB.
The percentage of Guaranteed Minimum bandwidth to
be assigned to the egress High-Priority queue for
this port. Total values for all four queues must not
exceed 100 percent."
::= { hpSwitchBWMinEgressPortConfigEntry 5 }
hpSwitchRateLimitPortConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 23 }
hpSwitchRateLimitPortConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchRateLimitPortConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "A table that contains information about the port
Rate-Limiting configurations on this switch."
::= { hpSwitchRateLimitPortConfig 1 }
hpSwitchRateLimitPortConfigEntry OBJECT-TYPE
SYNTAX HpSwitchRateLimitPortConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "The information associated with each port's
Rate-Limiting configuration."
INDEX { hpSwitchRateLimitPortIndex }
::= { hpSwitchRateLimitPortConfigTable 1 }
HpSwitchRateLimitPortConfigEntry ::=
SEQUENCE {
hpSwitchRateLimitPortIndex INTEGER,
hpSwitchRateLimitPortControlMode INTEGER,
hpSwitchRateLimitPortSingleControlPrct INTEGER,
hpSwitchRateLimitPortPrctLowPriority INTEGER,
hpSwitchRateLimitPortPrctNormalPriority INTEGER,
hpSwitchRateLimitPortPrctMedPriority INTEGER,
hpSwitchRateLimitPortPrctHighPriority INTEGER
}
hpSwitchRateLimitPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The ifIndex value which uniquely identifies a row
in the Interfaces Table."
::= { hpSwitchRateLimitPortConfigEntry 1 }
hpSwitchRateLimitPortControlMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
rateLimitPerPortOnly(2),
rateLimitPerQueue(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "The mode by which this port will be Rate-Limited
on ingress. If rateLimitPerPortOnly is configured,
there will be a single maximum rate for the entire
port. If rateLimitPerQueue is configured, the values
for each of the four queues indicate the maximum
percentage of port traffic that may be received by
that queue (the sum of these values must not exceed
100). When rate-limiting is disabled, there are no
maximum controls on ingress for this port."
::= { hpSwitchRateLimitPortConfigEntry 2 }
hpSwitchRateLimitPortSingleControlPrct OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION "When hpSwitchRateLimitPortControlMode is configured
for rateLimitPerPortOnly, this value is the maximum
percentage of traffic that may be received by this
port on ingress."
::= { hpSwitchRateLimitPortConfigEntry 3 }
hpSwitchRateLimitPortPrctLowPriority OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The maximum percentage of traffic that may be
received by this port's Low-Priority queue on ingress.
hpSwitchRateLimitPortControlMode must be configured to
use rateLimitPerQueue for this to take effect. A value
of 0-percent for any queue means that no traffic will
ever be received on this port for that ingress queue.
Total values for all four queues must not exceed 100
percent."
::= { hpSwitchRateLimitPortConfigEntry 4 }
hpSwitchRateLimitPortPrctNormalPriority OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The maximum percentage of traffic that may be
received by this port's Normal-Priority queue on
ingress. hpSwitchRateLimitPortControlMode must be
configured to use rateLimitPerQueue for this to take
effect. A value of 0-percent for any queue means that
no traffic will ever be received on this port for that
ingress queue. Total values for all four queues must
not exceed 100 percent."
::= { hpSwitchRateLimitPortConfigEntry 5 }
hpSwitchRateLimitPortPrctMedPriority OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The maximum percentage of traffic that may be
received by this port's Medium-Priority queue on
ingress. hpSwitchRateLimitPortControlMode must be
configured to use rateLimitPerQueue for this to take
effect. A value of 0-percent for any queue means that
no traffic will ever be received on this port for that
ingress queue. Total values for all four queues must
not exceed 100 percent."
::= { hpSwitchRateLimitPortConfigEntry 6 }
hpSwitchRateLimitPortPrctHighPriority OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The maximum percentage of traffic that may be
received by this port's High-Priority queue on
ingress. hpSwitchRateLimitPortControlMode must be
configured to use rateLimitPerQueue for this to take
effect. A value of 0-percent for any queue means that
no traffic will ever be received on this port for that
ingress queue. Total values for all four queues must
not exceed 100 percent."
::= { hpSwitchRateLimitPortConfigEntry 7 }
hpSwitchQosPassThroughMode OBJECT IDENTIFIER ::= { hpSwitchConfig 24 }
hpSwitchQosPassThroughModeConfig OBJECT-TYPE
SYNTAX INTEGER {
optimized (1),
typical (2),
balanced (3),
onequeue (4)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION "Specify the queue configuration mode for the switch.
While changing the queue configuration mode this feature
momentarily require to bring down the logical port and
after the initialisation of the queues the ports are
brought up."
::= { hpSwitchQosPassThroughMode 1 }
hpSwitchReboot OBJECT IDENTIFIER ::= { hpSwitchConfig 25 }
hpSwitchRebootConfig OBJECT-TYPE
SYNTAX INTEGER {
yes (1),
no (2)
}
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION "This tells the status of the switch whether it requires
reboot for some variable to get effective.
The value of this variable can be
yes (1) reboot is required.
no (2) reboot is not required."
::= { hpSwitchReboot 1 }
hpSwitchRebootFastBoot OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION "Specifies whether fastboot is enabled or not on
the switch."
DEFVAL { disable }
::= { hpSwitchReboot 2 }
hpSwitchProtectedPortsConfig OBJECT IDENTIFIER ::= { hpSwitchConfig 26 }
hpSwitchProtectedPortsMask OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION "This variable specifies a group of ports that are not
allowed to communicate to each-other. Each octet within
the value of this object specifies a set of eight ports,
with the first octet specifying ports 1 through 8, the
second octet specifying ports 9 through 16, etc.
Within each octet, the most significant bit represents
the lowest numbered port, and the least significant bit
represents the highest numbered port. Thus, each port
of the switch is represented by a single bit within
the value of this object."
::= { hpSwitchProtectedPortsConfig 1 }
-- **********************************************************
-- Trap Definitions
-- **********************************************************
hpSwitchTraps OBJECT IDENTIFIER ::= { hpSwitchConfig 0 }
hpSwitchTrapsObjects
OBJECT IDENTIFIER ::= { hpSwitchTraps 1 }
hpSwitchStpErrantBpduDetector OBJECT-TYPE
SYNTAX INTEGER {
bpduFilter (1),
bpduProtection (2),
pvstFilter (3),
pvstProtection (4)
}
ACCESS accessible-for-notify
STATUS optional
DESCRIPTION "The identifier of the feature generating Errant
BPDU trap."
::= { hpSwitchTrapsObjects 1 }
hpSwitchStpErrantBpduSrcMac OBJECT-TYPE
SYNTAX MacAddress
ACCESS accessible-for-notify
STATUS optional
DESCRIPTION "The source MAC address of the port sending Errant
STP BPDU."
::= { hpSwitchTrapsObjects 2 }
hpSwitchStpErrantBpduReceived TRAP-TYPE
ENTERPRISE hpSwitchTraps
VARIABLES { hpSwitchStpPort,
hpSwitchStpPortErrantBpduCounter,
dot1dStpPortState,
dot1dStpPortDesignatedBridge,
dot1dStpPortDesignatedPort,
hpSwitchStpErrantBpduSrcMac,
hpSwitchStpErrantBpduDetector }
DESCRIPTION "This trap indicates that unexpected (errant) STP BPDU
has been received on a port (e.g. on a port that is
connected to non-STP device). This notification trap
is controlled by the state of 'hpSwitchStpTrapCntl'
object. Implementation of this trap is optional."
::= 1
END