-- Rack Information MIB
|
||
-- Management Information Base for SNMP Network Management
|
||
--
|
||
--
|
||
-- Copyright 2002,2016 Hewlett Packard Enterprise Development LP
|
||
--
|
||
-- Hewlett Packard Enterprise shall not be liable for technical or
|
||
-- editorial errors or omissions contained herein. The information in
|
||
-- this document is provided "as is" without warranty of any kind and
|
||
-- is subject to change without notice. The warranties for HPE products
|
||
-- are set forth in the express limited warranty statements
|
||
-- accompanying such products. Nothing herein should be construed as
|
||
-- constituting an additional warranty.
|
||
--
|
||
-- Confidential computer software. Valid license from HPE required for
|
||
-- possession, use or copying. Consistent with FAR 12.211 and 12.212,
|
||
-- Commercial Computer Software, Computer Software Documentation, and
|
||
-- Technical Data for Commercial Items are licensed to the U.S.
|
||
-- Government under vendor's standard commercial license.
|
||
--
|
||
-- Refer to the READMIB.RDM file for more information about the
|
||
-- organization of the information in the Compaq Enterprise.
|
||
--
|
||
-- The Compaq Enterprise number is 232.
|
||
-- The ASN.1 prefix to, and including the Compaq Enterprise is:
|
||
-- 1.3.6.1.4.1.232
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
CPQRACK-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
compaq FROM CPQHOST-MIB
|
||
DisplayString FROM RFC1213-MIB
|
||
OBJECT-TYPE FROM RFC-1212
|
||
sysName FROM RFC1213-MIB
|
||
cpqHoTrapFlags FROM CPQHOST-MIB
|
||
TRAP-TYPE FROM RFC-1215
|
||
cpqHoOsType FROM CPQHOST-MIB
|
||
cpqHoVersion FROM CPQHOST-MIB;
|
||
|
||
-- compaq OBJECT IDENTIFIER ::= { enterprises 232 }
|
||
cpqRackInfo OBJECT IDENTIFIER ::= { compaq 22 }
|
||
cpqRackMibRev OBJECT IDENTIFIER ::= { cpqRackInfo 1 }
|
||
cpqRackComponent OBJECT IDENTIFIER ::= { cpqRackInfo 2 }
|
||
cpqRackSysObjID OBJECT IDENTIFIER ::= { cpqRackInfo 3 }
|
||
cpqRackEventInfo OBJECT IDENTIFIER ::= { cpqRackInfo 4 }
|
||
|
||
cpqRackInterface OBJECT IDENTIFIER ::= { cpqRackComponent 1 }
|
||
cpqRackAsset OBJECT IDENTIFIER ::= { cpqRackComponent 2 }
|
||
cpqRackEnclosure OBJECT IDENTIFIER ::= { cpqRackComponent 3 }
|
||
cpqRackServer OBJECT IDENTIFIER ::= { cpqRackComponent 4 }
|
||
cpqRackPower OBJECT IDENTIFIER ::= { cpqRackComponent 5 }
|
||
cpqRackNetwork OBJECT IDENTIFIER ::= { cpqRackComponent 6 }
|
||
cpqRackHW OBJECT IDENTIFIER ::= { cpqRackComponent 7 }
|
||
cpqRackErs OBJECT IDENTIFIER ::= { cpqRackComponent 8 }
|
||
|
||
cpqRackOsCommon OBJECT IDENTIFIER ::= { cpqRackInterface 4 }
|
||
|
||
cpqRackCommonEnclosure OBJECT IDENTIFIER ::= { cpqRackEnclosure 1 }
|
||
cpqRackServerEnclosure OBJECT IDENTIFIER ::= { cpqRackEnclosure 2 }
|
||
cpqRackPowerEnclosure OBJECT IDENTIFIER ::= { cpqRackEnclosure 3 }
|
||
|
||
cpqRackServerBlade OBJECT IDENTIFIER ::= { cpqRackServer 1 }
|
||
cpqRackServerNetworking OBJECT IDENTIFIER ::= { cpqRackServer 2 }
|
||
cpqRackServerTempSensor OBJECT IDENTIFIER ::= { cpqRackServer 3 }
|
||
|
||
cpqRackPowerSupply OBJECT IDENTIFIER ::= { cpqRackPower 1 }
|
||
|
||
cpqRackNetConnector OBJECT IDENTIFIER ::= { cpqRackNetwork 1 }
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Information MIB Revision
|
||
-- =============================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackMibRev Group (1.3.6.1.4.1.232.22.1)
|
||
--
|
||
-- Implementation of the MibRev group is mandatory for all Agents
|
||
-- supporting the Rack Information MIB.
|
||
--
|
||
-- An Agent conforming to this document will return a
|
||
-- cpqRackMibRevMajor of one (1) and a cpqRackMibRevMinor of twenty one (21).
|
||
--
|
||
-- Added trap cpqRackEnclosureManagerLinkDown (22083)
|
||
-- Added trap cpqRackEnclosureManagerLinkUp (22084)
|
||
-- Added group - cpqRackErs in cpqRackComponent
|
||
-- Added trap cpqRackErsCommFailure (22085)
|
||
-- Added trap cpqRackPowerSubsystemOverloadConditionRepaired (22086)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackMibRevMajor OBJECT-TYPE
|
||
SYNTAX INTEGER (1..65535)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The major revision level of the MIB.
|
||
|
||
A change in the major revision level represents a major change
|
||
in the architecture of the MIB. A change in the major revision
|
||
level may indicate a significant change in the information
|
||
supported and/or the meaning of the supported information,
|
||
correct interpretation of data may require a MIB document with
|
||
the same major revision level."
|
||
::= { cpqRackMibRev 1 }
|
||
|
||
cpqRackMibRevMinor OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The minor revision level of the MIB.
|
||
|
||
A change in the minor revision level may represent some minor
|
||
additional support, no changes to any pre-existing information
|
||
has occurred."
|
||
::= { cpqRackMibRev 2 }
|
||
|
||
cpqRackMibCondition OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
ok(2), -- default
|
||
degraded(3),
|
||
failed(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The overall condition.
|
||
|
||
This object represents the overall status of the
|
||
rack information represented by this MIB."
|
||
::= { cpqRackMibRev 3 }
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Information Common
|
||
-- =======================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackInterface Group (1.3.6.1.4.1.232.22.2.1)
|
||
-- cpqRackOsCommon Group (1.3.6.1.4.1.232.22.2.1.4)
|
||
--
|
||
--
|
||
-- Implementation of the cpqRackOsCommon group is mandatory for all
|
||
-- Agents that support the Rack Information MIB.
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackOsCommonPollFreq OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The Management Agent's polling frequency.
|
||
|
||
The frequency, in seconds, at which the Agent requests
|
||
information from the device driver. A frequency of zero (0)
|
||
indicates that the Insight Agent retrieves the information upon
|
||
request of a management station, it does not poll the device
|
||
driver at a specific interval.
|
||
|
||
If the poll frequency is zero (0) all attempts to write to this
|
||
object will fail. If the poll frequency is non-zero,
|
||
setting this value will change the polling frequency of the
|
||
Insight Agent. Setting the poll frequency to zero (0) will
|
||
always fail, an agent may also choose to fail any request to
|
||
change the poll frequency to a value that would severely impact
|
||
system performance."
|
||
::= { cpqRackOsCommon 1 }
|
||
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Asset Group
|
||
-- ================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackAsset Group (1.3.6.1.4.1.232.22.2.2)
|
||
--
|
||
-- The cpqRackAsset group contains the serial numbers, names, etc. of any
|
||
-- Rack hardware that supports asset management.
|
||
--
|
||
-- Implementation of the cpqRackAsset group is mandatory for all
|
||
-- Agents that support the Rack Information MIB.
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Asset Table
|
||
-- ================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackAsset Group (1.3.6.1.4.1.232.22.2.2)
|
||
-- cpqRackAssetTable (1.3.6.1.4.1.232.22.2.2.1)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackAssetTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CpqRackAssetEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A table of rack asset information."
|
||
::= { cpqRackAsset 1 }
|
||
|
||
cpqRackAssetEntry OBJECT-TYPE
|
||
SYNTAX CpqRackAssetEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A rack asset description."
|
||
INDEX { cpqRackAssetIndex }
|
||
::= { cpqRackAssetTable 1 }
|
||
|
||
CpqRackAssetEntry ::= SEQUENCE {
|
||
cpqRackAssetIndex INTEGER,
|
||
cpqRackName DisplayString,
|
||
cpqRackUid DisplayString,
|
||
cpqRackSerialNum DisplayString,
|
||
cpqRackTrapSequenceNum INTEGER,
|
||
cpqRackHeight INTEGER,
|
||
cpqRackWidth INTEGER,
|
||
cpqRackDepth INTEGER
|
||
}
|
||
|
||
cpqRackAssetIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this rack table entry."
|
||
::= { cpqRackAssetEntry 1 }
|
||
|
||
cpqRackName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The customer changeable identifier used to identify the entire
|
||
rack.
|
||
|
||
The string will be empty if the system does not report this
|
||
function."
|
||
::= { cpqRackAssetEntry 2 }
|
||
|
||
cpqRackUid OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The rack unique identifier.
|
||
|
||
The string will be empty if the rack does not report the
|
||
UID or if it could not be determined."
|
||
::= { cpqRackAssetEntry 3 }
|
||
|
||
cpqRackSerialNum OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The rack serial number.
|
||
|
||
The string will be empty if the rack does not report the
|
||
serial number."
|
||
::= { cpqRackAssetEntry 4 }
|
||
|
||
cpqRackTrapSequenceNum OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The trap sequence number for rack traps.
|
||
|
||
This is used by the management application trap processing.
|
||
|
||
This will be -1 if the rack does not report the information or
|
||
it could not be determined."
|
||
::= { cpqRackAssetEntry 5 }
|
||
|
||
cpqRackHeight OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The internal height dimension of the useable rack space expressed
|
||
in millimeters.
|
||
|
||
This will be -1 if the rack does not report the information or
|
||
it could not be determined."
|
||
::= { cpqRackAssetEntry 6 }
|
||
|
||
cpqRackWidth OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The internal width dimension of the useable rack space expressed
|
||
in millimeters.
|
||
|
||
This will be -1 if the rack does not report the information or
|
||
it could not be determined."
|
||
::= { cpqRackAssetEntry 7 }
|
||
|
||
cpqRackDepth OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The internal depth dimension of the useable rack space expressed
|
||
in millimeters.
|
||
|
||
This will be -1 if the rack does not report the information or
|
||
it could not be determined."
|
||
::= { cpqRackAssetEntry 8 }
|
||
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Enclosure Chassis Group
|
||
-- ============================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
|
||
--
|
||
-- The cpqRackEnclosure group contains the information about rack
|
||
-- enclosures.
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Common Enclosure Table
|
||
-- ===========================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
|
||
-- cpqRackCommonEnclosure Group (1.3.6.1.4.1.232.22.2.3.1)
|
||
-- cpqRackCommonEnclosureTable (1.3.6.1.4.1.232.22.2.3.1.1)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackCommonEnclosureTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CpqRackCommonEnclosureEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A table of rack enclosure information."
|
||
::= { cpqRackCommonEnclosure 1 }
|
||
|
||
cpqRackCommonEnclosureEntry OBJECT-TYPE
|
||
SYNTAX CpqRackCommonEnclosureEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A rack enclosure description."
|
||
INDEX { cpqRackCommonEnclosureRack,
|
||
cpqRackCommonEnclosureIndex }
|
||
::= { cpqRackCommonEnclosureTable 1 }
|
||
|
||
CpqRackCommonEnclosureEntry ::= SEQUENCE {
|
||
cpqRackCommonEnclosureRack INTEGER,
|
||
cpqRackCommonEnclosureIndex INTEGER,
|
||
cpqRackCommonEnclosureModel DisplayString,
|
||
cpqRackCommonEnclosureAssetTag DisplayString,
|
||
cpqRackCommonEnclosurePartNumber DisplayString,
|
||
cpqRackCommonEnclosureSparePartNumber DisplayString,
|
||
cpqRackCommonEnclosureSerialNum DisplayString,
|
||
cpqRackCommonEnclosureFWRev DisplayString,
|
||
cpqRackCommonEnclosureName DisplayString,
|
||
cpqRackCommonEnclosureNeighborNamePrev DisplayString,
|
||
cpqRackCommonEnclosureNeighborNameNext DisplayString,
|
||
cpqRackCommonEnclosureHeight INTEGER,
|
||
cpqRackCommonEnclosureWidth INTEGER,
|
||
cpqRackCommonEnclosureDepth INTEGER,
|
||
cpqRackCommonEnclosureTrapSequenceNum INTEGER,
|
||
cpqRackCommonEnclosureCondition INTEGER,
|
||
cpqRackCommonEnclosureHasServerBlades INTEGER,
|
||
cpqRackCommonEnclosureHasPowerSupplies INTEGER,
|
||
cpqRackCommonEnclosureHasNetConnectors INTEGER,
|
||
cpqRackCommonEnclosureHasTempSensors INTEGER,
|
||
cpqRackCommonEnclosureHasFans INTEGER,
|
||
cpqRackCommonEnclosureHasFuses INTEGER,
|
||
cpqRackCommonEnclosureMgmtUID INTEGER,
|
||
cpqRackCommonEnclosureSerialNumPrev DisplayString,
|
||
cpqRackCommonEnclosureSerialNumNext DisplayString,
|
||
cpqRackCommonEnclosureAddress INTEGER,
|
||
cpqRackCommonEnclosureProductId DisplayString,
|
||
cpqRackCommonEnclosureProductIdPrev DisplayString,
|
||
cpqRackCommonEnclosureProductIdNext DisplayString,
|
||
cpqRackCommonEnclosureUUID DisplayString,
|
||
cpqRackCommonEnclosureUUIDPrev DisplayString,
|
||
cpqRackCommonEnclosureUUIDNext DisplayString,
|
||
cpqRackCommonEnclosureHasManagers INTEGER
|
||
}
|
||
|
||
cpqRackCommonEnclosureRack OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this rack."
|
||
::= { cpqRackCommonEnclosureEntry 1 }
|
||
|
||
cpqRackCommonEnclosureIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this enclosure in the rack."
|
||
::= { cpqRackCommonEnclosureEntry 2 }
|
||
|
||
cpqRackCommonEnclosureModel OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The model name of the enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
model information."
|
||
::= { cpqRackCommonEnclosureEntry 3 }
|
||
|
||
cpqRackCommonEnclosureAssetTag OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The customer changeable asset identifier of the enclosure.
|
||
|
||
The string will be empty if the system does not report this
|
||
function or if the asset tag has not been set."
|
||
::= { cpqRackCommonEnclosureEntry 4 }
|
||
|
||
cpqRackCommonEnclosurePartNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The part number of the enclosure.
|
||
|
||
The string will be empty if the enclosure does not report this
|
||
function."
|
||
::= { cpqRackCommonEnclosureEntry 5 }
|
||
|
||
cpqRackCommonEnclosureSparePartNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The spare part number of the enclosure.
|
||
|
||
The string will be empty if the enclosure does not report this
|
||
function."
|
||
::= { cpqRackCommonEnclosureEntry 6 }
|
||
|
||
cpqRackCommonEnclosureSerialNum OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The serial number of the enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
serial number."
|
||
::= { cpqRackCommonEnclosureEntry 7 }
|
||
|
||
cpqRackCommonEnclosureFWRev OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The firmware revision of the enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
firmware revision or does not contain firmware."
|
||
::= { cpqRackCommonEnclosureEntry 8 }
|
||
|
||
cpqRackCommonEnclosureName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The name of the enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
name or it could not be determined."
|
||
::= { cpqRackCommonEnclosureEntry 9 }
|
||
|
||
cpqRackCommonEnclosureNeighborNamePrev OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The name of the enclosure immediately preceding or above this
|
||
enclosure.
|
||
|
||
The string will be empty if the neighbor enclosure name could not be
|
||
determined or there is no enclosure preceding this one."
|
||
::= { cpqRackCommonEnclosureEntry 10 }
|
||
|
||
cpqRackCommonEnclosureNeighborNameNext OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The name of the enclosure immediately following or below this
|
||
enclosure.
|
||
|
||
The string will be empty if the neighbor enclosure name could not be
|
||
determined or there is no enclosure following this one."
|
||
::= { cpqRackCommonEnclosureEntry 11 }
|
||
|
||
cpqRackCommonEnclosureHeight OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The height dimension of the rack space taken by the
|
||
enclosure expressed in millimeters.
|
||
|
||
This will be -1 if the rack does not report the information or
|
||
it could not be determined."
|
||
::= { cpqRackCommonEnclosureEntry 12 }
|
||
|
||
cpqRackCommonEnclosureWidth OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The width dimension of the rack space taken by the
|
||
enclosure expressed in millimeters.
|
||
|
||
This will be -1 if the rack does not report the information or
|
||
it could not be determined."
|
||
::= { cpqRackCommonEnclosureEntry 13 }
|
||
|
||
cpqRackCommonEnclosureDepth OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The depth dimension of the rack space taken by the
|
||
enclosure expressed in millimeters.
|
||
|
||
This will be -1 if the rack does not report the information or
|
||
it could not be determined."
|
||
::= { cpqRackCommonEnclosureEntry 14 }
|
||
|
||
cpqRackCommonEnclosureTrapSequenceNum OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The trap sequence number for the enclosure.
|
||
|
||
This is used by the management application trap processing.
|
||
|
||
This will be -1 if the rack does not report the information or
|
||
it could not be determined."
|
||
::= { cpqRackCommonEnclosureEntry 15 }
|
||
|
||
cpqRackCommonEnclosureCondition OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
ok(2),
|
||
degraded(3),
|
||
failed(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The overall condition of the enclosure.
|
||
|
||
This is the aggregate of the temperature sensors, fans, and
|
||
fuses within the enclosure.
|
||
|
||
This value will be one of the following:
|
||
|
||
other(1)
|
||
No temperature sensors, fans, or fuses in the enclosure or the
|
||
state could no be determined.
|
||
|
||
ok(2)
|
||
All temperature sensors, fans, and fuses are within the normal
|
||
operating range.
|
||
|
||
degraded(3)
|
||
One or more temperature sensors, fans, or fuses are outside of
|
||
the normal operating range. None are failed.
|
||
|
||
failed(4)
|
||
The temperature sensor exceeded the critical threshold value,
|
||
a required fan has failed, or a fuse has been tripped.
|
||
|
||
The system will automatically shutdown if the failed(4) condition
|
||
results, so it is unlikely that this value will ever be returned
|
||
by the agent."
|
||
::= { cpqRackCommonEnclosureEntry 16 }
|
||
|
||
cpqRackCommonEnclosureHasServerBlades OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
false(1),
|
||
true(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The enclosure can contain server blades.
|
||
|
||
This will be true(2) is the enclosure can house server blades. The
|
||
cpqRackServerEnclosureTable will contain server enclosure specific
|
||
information.
|
||
|
||
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
||
serial number in the cpqRackServerEnclosureTable to get complete
|
||
information on the server enclosure."
|
||
::= { cpqRackCommonEnclosureEntry 17 }
|
||
|
||
cpqRackCommonEnclosureHasPowerSupplies OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
false(1),
|
||
true(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The enclosure can contain power supplies.
|
||
|
||
This will be true(2) is the enclosure can house power supplies. The
|
||
cpqRackEnclosurePowerTable will contain power enclosure specific
|
||
information.
|
||
|
||
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
||
serial number in the cpqRackEnclosurePowerTable to get complete
|
||
information on the power enclosure."
|
||
::= { cpqRackCommonEnclosureEntry 18 }
|
||
|
||
cpqRackCommonEnclosureHasNetConnectors OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
false(1),
|
||
true(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The enclosure contains network connectivity.
|
||
|
||
This will be true(2) is the enclosure contains network connectivity.
|
||
The cpqRackCommonEnclosureNetConnectorTable will contain network
|
||
connectivity specific information.
|
||
|
||
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
||
serial number in the cpqRackCommonEnclosureNetConnectorTable to get complete
|
||
information on the network connector enclosure."
|
||
::= { cpqRackCommonEnclosureEntry 19 }
|
||
|
||
cpqRackCommonEnclosureHasTempSensors OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
false(1),
|
||
true(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The enclosure contains temperature sensors.
|
||
|
||
This will be true(2) is the enclosure contains
|
||
temperature sensors. The cpqRackCommonEnclosureTempTable will
|
||
contain temperature sensor specific information.
|
||
|
||
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
||
serial number in the cpqRackCommonEnclosureTempTable to get complete
|
||
information on the enclosure."
|
||
::= { cpqRackCommonEnclosureEntry 20 }
|
||
|
||
cpqRackCommonEnclosureHasFans OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
false(1),
|
||
true(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The enclosure contains fans.
|
||
|
||
This will be true(2) is the enclosure contains fans.
|
||
The cpqRackCommonEnclosureFanTable will contain the fan
|
||
specific information.
|
||
|
||
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
||
serial number in the cpqRackCommonEnclosureFanTable to get complete
|
||
information on the enclosure."
|
||
::= { cpqRackCommonEnclosureEntry 21 }
|
||
|
||
cpqRackCommonEnclosureHasFuses OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
false(1),
|
||
true(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The enclosure contains fuses.
|
||
|
||
This will be true(2) is the enclosure contains fuses.
|
||
The cpqRackCommonEnclosureFuseTable will contain the fuse
|
||
specific information.
|
||
|
||
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
||
serial number in the cpqRackCommonEnclosureFuseTable to get complete
|
||
information on the enclosure."
|
||
::= { cpqRackCommonEnclosureEntry 22 }
|
||
|
||
cpqRackCommonEnclosureMgmtUID OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1), -- Unknown device or could not be determined
|
||
none(2), -- No Unit Identifier LED present
|
||
ledOn(3), -- Unit Identifier LED is On
|
||
ledOff(4) -- Unit Identifier LED is Off
|
||
}
|
||
ACCESS read-write
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The Unit Identifier LED.
|
||
|
||
This value will be one of the following:
|
||
|
||
other(1)
|
||
The state of the LED could not be determined. Setting the
|
||
LED state is not allowed.
|
||
|
||
none(2)
|
||
The LED is not present. Setting LED state is not allowed.
|
||
|
||
ledOn(3)
|
||
The LED is present and ON. The LED can be turned off
|
||
by setting the cpqRackCommonEnclosureMgmtUID to ledOff(4).
|
||
|
||
ledOff(4)
|
||
The LED is present and OFF. The LED can be turned on
|
||
by setting the cpqRackCommonEnclosureMgmtUID to ledOn(3)."
|
||
::= { cpqRackCommonEnclosureEntry 23 }
|
||
|
||
cpqRackCommonEnclosureSerialNumPrev OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The serial number of the enclosure immediately preceding or
|
||
above this enclosure.
|
||
|
||
The string will be empty if the neighbor enclosure serial number
|
||
could not be determined or there is no enclosure preceding this one."
|
||
::= { cpqRackCommonEnclosureEntry 24 }
|
||
|
||
cpqRackCommonEnclosureSerialNumNext OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The serial number of the enclosure immediately following or
|
||
below this enclosure.
|
||
|
||
The string will be empty if the neighbor enclosure serial number
|
||
could not be determined or there is no enclosure following this one."
|
||
::= { cpqRackCommonEnclosureEntry 25 }
|
||
|
||
cpqRackCommonEnclosureAddress OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The unique address of the enclosure within the rack.
|
||
|
||
This will be -1 if the rack does not report the information or
|
||
it could not be determined."
|
||
::= { cpqRackCommonEnclosureEntry 26 }
|
||
|
||
cpqRackCommonEnclosureProductId OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The product id string of the enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
product id string."
|
||
::= { cpqRackCommonEnclosureEntry 27 }
|
||
|
||
cpqRackCommonEnclosureProductIdPrev OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The product id string of the enclosure immediately preceding or
|
||
above this enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
product id string."
|
||
::= { cpqRackCommonEnclosureEntry 28 }
|
||
|
||
cpqRackCommonEnclosureProductIdNext OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The product id string of the enclosure immediately following or
|
||
below this enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
product id string."
|
||
::= { cpqRackCommonEnclosureEntry 29 }
|
||
|
||
cpqRackCommonEnclosureUUID OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The universal unique identifier string of the enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
UUID string."
|
||
::= { cpqRackCommonEnclosureEntry 30 }
|
||
|
||
cpqRackCommonEnclosureUUIDPrev OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The universal unique identifier string of the enclosure
|
||
immediately preceding or above this enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
UUID string or if there is no preceding enclosure."
|
||
::= { cpqRackCommonEnclosureEntry 31 }
|
||
|
||
cpqRackCommonEnclosureUUIDNext OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The universal unique identifier string of the enclosure
|
||
immediately following or below this enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
UUID string or if there is no following enclosure."
|
||
::= { cpqRackCommonEnclosureEntry 32 }
|
||
|
||
cpqRackCommonEnclosureHasManagers OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
false(1),
|
||
true(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The enclosure contains managers.
|
||
|
||
This will be true(2) is the enclosure contains managers.
|
||
The cpqRackCommonEnclosureManagerTable will contain the manager
|
||
specific information.
|
||
|
||
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
||
serial number in the cpqRackCommonEnclosureManagerTable to get
|
||
complete information on the enclosure."
|
||
::= { cpqRackCommonEnclosureEntry 33 }
|
||
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Enclosure Common Temperature Sensor Table
|
||
-- ==============================================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
|
||
-- cpqRackCommonEnclosure Group (1.3.6.1.4.1.232.22.2.3.1)
|
||
-- cpqRackCommonEnclosureTempTable (1.3.6.1.4.1.232.22.2.3.1.2)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackCommonEnclosureTempTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CpqRackCommonEnclosureTempEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A table of rack enclosure temperature sensor information."
|
||
::= { cpqRackCommonEnclosure 2 }
|
||
|
||
cpqRackCommonEnclosureTempEntry OBJECT-TYPE
|
||
SYNTAX CpqRackCommonEnclosureTempEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A rack enclosure temperature sensor description."
|
||
INDEX { cpqRackCommonEnclosureTempRack,
|
||
cpqRackCommonEnclosureTempChassis,
|
||
cpqRackCommonEnclosureTempSensorIndex }
|
||
::= { cpqRackCommonEnclosureTempTable 1 }
|
||
|
||
CpqRackCommonEnclosureTempEntry ::= SEQUENCE {
|
||
cpqRackCommonEnclosureTempRack INTEGER,
|
||
cpqRackCommonEnclosureTempChassis INTEGER,
|
||
cpqRackCommonEnclosureTempSensorIndex INTEGER,
|
||
cpqRackCommonEnclosureTempSensorEnclosureName DisplayString,
|
||
cpqRackCommonEnclosureTempLocation DisplayString,
|
||
cpqRackCommonEnclosureTempCurrent INTEGER,
|
||
cpqRackCommonEnclosureTempThreshold INTEGER,
|
||
cpqRackCommonEnclosureTempCondition INTEGER,
|
||
cpqRackCommonEnclosureTempType INTEGER,
|
||
cpqRackCommonEnclosureTempSensorEnclosureSerialNum DisplayString
|
||
}
|
||
|
||
cpqRackCommonEnclosureTempRack OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this rack."
|
||
::= { cpqRackCommonEnclosureTempEntry 1 }
|
||
|
||
cpqRackCommonEnclosureTempChassis OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this enclosure in the rack."
|
||
::= { cpqRackCommonEnclosureTempEntry 2 }
|
||
|
||
cpqRackCommonEnclosureTempSensorIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this temperature sensor within
|
||
this enclosure in the rack."
|
||
::= { cpqRackCommonEnclosureTempEntry 3 }
|
||
|
||
cpqRackCommonEnclosureTempSensorEnclosureName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The name of the enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
name or it could not be determined."
|
||
::= { cpqRackCommonEnclosureTempEntry 4 }
|
||
|
||
cpqRackCommonEnclosureTempLocation OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The location description of the temperature sensor within the
|
||
enclosure.
|
||
|
||
The string will be empty if the location could not be
|
||
determined."
|
||
::= { cpqRackCommonEnclosureTempEntry 5 }
|
||
|
||
cpqRackCommonEnclosureTempCurrent OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This is the current temperature sensor reading in degrees
|
||
celsius.
|
||
|
||
If this value cannot be determined by software, then a value
|
||
of -1 will be returned."
|
||
::= { cpqRackCommonEnclosureTempEntry 6 }
|
||
|
||
cpqRackCommonEnclosureTempThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This is the threshold temperature sensor setting
|
||
in degrees celsius. This is the temperature in which the
|
||
sensor will be considered to be in a tripped state this
|
||
causing some action to occur depending on the type of
|
||
the sensor. The action of temperature sensor threshold
|
||
will be indicated by the cpqRackCommonEnclosureTempType
|
||
item. If the type is blowout(5), then the temperature sensor
|
||
will cause the fans to speed up. If the type is caution(9),
|
||
then the temperature sensor is in a degraded state. If the
|
||
type is critical(15), then the enclosure will be considered
|
||
as in a failed state.
|
||
|
||
If this value cannot be determined by software, then a value
|
||
of -1 will be returned."
|
||
::= { cpqRackCommonEnclosureTempEntry 7 }
|
||
|
||
cpqRackCommonEnclosureTempCondition OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
ok(2),
|
||
degraded(3),
|
||
failed(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The Temperature sensor condition.
|
||
|
||
This value will be one of the following:
|
||
|
||
other(1)
|
||
Temperature could not be determined.
|
||
|
||
ok(2)
|
||
The temperature sensor is within the normal operating range.
|
||
|
||
degraded(3)
|
||
The temperature sensor is outside of the normal operating range.
|
||
|
||
failed(4)
|
||
The temperature sensor detects a condition that could
|
||
possibly damage the system.
|
||
|
||
The system will automatically shutdown if the failed(4) condition
|
||
results, so it is unlikely that this value will ever be returned
|
||
by the agent."
|
||
::= { cpqRackCommonEnclosureTempEntry 8 }
|
||
|
||
cpqRackCommonEnclosureTempType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
blowout(5),
|
||
caution(9),
|
||
critical(15)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This specifies the type of this instance of temperature
|
||
sensor.
|
||
|
||
This value will be one of the following:
|
||
|
||
other(1)
|
||
Temperature threshold type could not be determined.
|
||
|
||
blowout(5)
|
||
If a blowout(5) temperature sensor reaches its threshold,
|
||
the fan or fans in the area of the temperature sensor will
|
||
increase in speed in an attempt to reduce the temperature
|
||
before a caution or critical threshold is reached.
|
||
|
||
caution(9)
|
||
If a caution(9) temperature sensor reaches its threshold, the
|
||
cpqRackCommonEnclosureTempCondition will be set to degraded(3)
|
||
and the system will either continue or shutdown depending
|
||
on the user preferences.
|
||
|
||
critical(15)
|
||
If a critical(15) temperature sensor reaches its threshold,
|
||
the cpqHeTemperatureCondition will be set to failed(4)
|
||
and the system will shutdown."
|
||
::= { cpqRackCommonEnclosureTempEntry 9 }
|
||
|
||
cpqRackCommonEnclosureTempSensorEnclosureSerialNum OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The serial number of the enclosure containing this temperature
|
||
sensor.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
serial number or it could not be determined."
|
||
::= { cpqRackCommonEnclosureTempEntry 10 }
|
||
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Enclosure Common Fan Table
|
||
-- ===============================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
|
||
-- cpqRackCommonEnclosure Group (1.3.6.1.4.1.232.22.2.3.1)
|
||
-- cpqRackCommonEnclosureFanTable (1.3.6.1.4.1.232.22.2.3.1.3)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackCommonEnclosureFanTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CpqRackCommonEnclosureFanEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A table of rack enclosure fan information."
|
||
::= { cpqRackCommonEnclosure 3 }
|
||
|
||
cpqRackCommonEnclosureFanEntry OBJECT-TYPE
|
||
SYNTAX CpqRackCommonEnclosureFanEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A rack enclosure fan description."
|
||
INDEX { cpqRackCommonEnclosureFanRack,
|
||
cpqRackCommonEnclosureFanChassis,
|
||
cpqRackCommonEnclosureFanIndex }
|
||
::= { cpqRackCommonEnclosureFanTable 1 }
|
||
|
||
CpqRackCommonEnclosureFanEntry ::= SEQUENCE {
|
||
cpqRackCommonEnclosureFanRack INTEGER,
|
||
cpqRackCommonEnclosureFanChassis INTEGER,
|
||
cpqRackCommonEnclosureFanIndex INTEGER,
|
||
cpqRackCommonEnclosureFanEnclosureName DisplayString,
|
||
cpqRackCommonEnclosureFanLocation DisplayString,
|
||
cpqRackCommonEnclosureFanPartNumber DisplayString,
|
||
cpqRackCommonEnclosureFanSparePartNumber DisplayString,
|
||
cpqRackCommonEnclosureFanPresent INTEGER,
|
||
cpqRackCommonEnclosureFanRedundant INTEGER,
|
||
cpqRackCommonEnclosureFanRedundantGroupId INTEGER,
|
||
cpqRackCommonEnclosureFanCondition INTEGER,
|
||
cpqRackCommonEnclosureFanEnclosureSerialNum DisplayString
|
||
}
|
||
|
||
cpqRackCommonEnclosureFanRack OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this rack."
|
||
::= { cpqRackCommonEnclosureFanEntry 1 }
|
||
|
||
cpqRackCommonEnclosureFanChassis OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this enclosure in the rack."
|
||
::= { cpqRackCommonEnclosureFanEntry 2 }
|
||
|
||
cpqRackCommonEnclosureFanIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this fan within this
|
||
enclosure in the rack."
|
||
::= { cpqRackCommonEnclosureFanEntry 3 }
|
||
|
||
cpqRackCommonEnclosureFanEnclosureName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The name of the enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
name or it could not be determined."
|
||
::= { cpqRackCommonEnclosureFanEntry 4 }
|
||
|
||
cpqRackCommonEnclosureFanLocation OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The location description of the fan within the enclosure.
|
||
|
||
The string will be empty if the location could not be
|
||
determined."
|
||
::= { cpqRackCommonEnclosureFanEntry 5 }
|
||
|
||
cpqRackCommonEnclosureFanPartNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The part number of the enclosure fan.
|
||
|
||
The string will be empty if the part number could not be
|
||
determined."
|
||
::= { cpqRackCommonEnclosureFanEntry 6 }
|
||
|
||
cpqRackCommonEnclosureFanSparePartNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The spare part number of the enclosure fan.
|
||
|
||
The string will be empty if the part number could not be
|
||
determined."
|
||
::= { cpqRackCommonEnclosureFanEntry 7 }
|
||
|
||
cpqRackCommonEnclosureFanPresent OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
absent(2),
|
||
present(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This specifies if the fan described is present in the system."
|
||
::= { cpqRackCommonEnclosureFanEntry 8 }
|
||
|
||
cpqRackCommonEnclosureFanRedundant OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
notRedundant(2),
|
||
redundant(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This specifies if the fan is in a redundant configuration."
|
||
::= { cpqRackCommonEnclosureFanEntry 9 }
|
||
|
||
cpqRackCommonEnclosureFanRedundantGroupId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This specifies the group number for redundant fans within this
|
||
enclosure."
|
||
::= { cpqRackCommonEnclosureFanEntry 10 }
|
||
|
||
cpqRackCommonEnclosureFanCondition OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
ok(2),
|
||
degraded(3),
|
||
failed(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The condition of the fan.
|
||
|
||
This value will be one of the following:
|
||
|
||
other(1)
|
||
Fan status detection is not supported.
|
||
|
||
ok(2)
|
||
The fan is operating properly.
|
||
|
||
degraded(2)
|
||
A redundant fan is not operating properly.
|
||
|
||
failed(4)
|
||
A non-redundant fan is not operating properly."
|
||
::= { cpqRackCommonEnclosureFanEntry 11 }
|
||
|
||
cpqRackCommonEnclosureFanEnclosureSerialNum OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The serial number of the enclosure containing the fan.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
serial number or it could not be determined."
|
||
::= { cpqRackCommonEnclosureFanEntry 12 }
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Enclosure Common Fuse Table
|
||
-- ================================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
|
||
-- cpqRackCommonEnclosure Group (1.3.6.1.4.1.232.22.2.3.1)
|
||
-- cpqRackCommonEnclosureFuseTable (1.3.6.1.4.1.232.22.2.3.1.4)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackCommonEnclosureFuseTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CpqRackCommonEnclosureFuseEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A table of rack enclosure fuse information."
|
||
::= { cpqRackCommonEnclosure 4 }
|
||
|
||
cpqRackCommonEnclosureFuseEntry OBJECT-TYPE
|
||
SYNTAX CpqRackCommonEnclosureFuseEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A rack enclosure fuse description."
|
||
INDEX { cpqRackCommonEnclosureFuseRack,
|
||
cpqRackCommonEnclosureFuseChassis,
|
||
cpqRackCommonEnclosureFuseIndex }
|
||
::= { cpqRackCommonEnclosureFuseTable 1 }
|
||
|
||
CpqRackCommonEnclosureFuseEntry ::= SEQUENCE {
|
||
cpqRackCommonEnclosureFuseRack INTEGER,
|
||
cpqRackCommonEnclosureFuseChassis INTEGER,
|
||
cpqRackCommonEnclosureFuseIndex INTEGER,
|
||
cpqRackCommonEnclosureFuseEnclosureName DisplayString,
|
||
cpqRackCommonEnclosureFuseLocation DisplayString,
|
||
cpqRackCommonEnclosureFusePresent INTEGER,
|
||
cpqRackCommonEnclosureFuseCondition INTEGER
|
||
}
|
||
|
||
cpqRackCommonEnclosureFuseRack OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this rack."
|
||
::= { cpqRackCommonEnclosureFuseEntry 1 }
|
||
|
||
cpqRackCommonEnclosureFuseChassis OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this enclosure in the rack."
|
||
::= { cpqRackCommonEnclosureFuseEntry 2 }
|
||
|
||
cpqRackCommonEnclosureFuseIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies the fuse within this enclosure."
|
||
::= { cpqRackCommonEnclosureFuseEntry 3 }
|
||
|
||
cpqRackCommonEnclosureFuseEnclosureName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The name of the enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
name or it could not be determined."
|
||
::= { cpqRackCommonEnclosureFuseEntry 4 }
|
||
|
||
cpqRackCommonEnclosureFuseLocation OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The location description of the fuse within the enclosure.
|
||
|
||
The string will be empty if the location could not be
|
||
determined."
|
||
::= { cpqRackCommonEnclosureFuseEntry 5 }
|
||
|
||
cpqRackCommonEnclosureFusePresent OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
absent(2),
|
||
present(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This specifies if the fuse described is present in the system."
|
||
::= { cpqRackCommonEnclosureFuseEntry 6 }
|
||
|
||
cpqRackCommonEnclosureFuseCondition OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
ok(2),
|
||
failed(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The condition of the fuse.
|
||
|
||
This value will be one of the following:
|
||
|
||
other(1)
|
||
Fuse status detection is not supported.
|
||
|
||
ok(2)
|
||
The fuse is operating properly.
|
||
|
||
failed(4)
|
||
A fuse has been tripped or is not operating properly."
|
||
::= { cpqRackCommonEnclosureFuseEntry 7 }
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Enclosure Common FRU Table
|
||
-- ===============================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
|
||
-- cpqRackCommonEnclosure Group (1.3.6.1.4.1.232.22.2.3.1)
|
||
-- cpqRackCommonEnclosureFruTable (1.3.6.1.4.1.232.22.2.3.1.5)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackCommonEnclosureFruTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CpqRackCommonEnclosureFruEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A table of rack enclosure field replaceable units information."
|
||
::= { cpqRackCommonEnclosure 5 }
|
||
|
||
cpqRackCommonEnclosureFruEntry OBJECT-TYPE
|
||
SYNTAX CpqRackCommonEnclosureFruEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A rack enclosure field replaceable unit description."
|
||
INDEX { cpqRackCommonEnclosureFruRack,
|
||
cpqRackCommonEnclosureFruChassis,
|
||
cpqRackCommonEnclosureFruIndex }
|
||
::= { cpqRackCommonEnclosureFruTable 1 }
|
||
|
||
CpqRackCommonEnclosureFruEntry ::= SEQUENCE {
|
||
cpqRackCommonEnclosureFruRack INTEGER,
|
||
cpqRackCommonEnclosureFruChassis INTEGER,
|
||
cpqRackCommonEnclosureFruIndex INTEGER,
|
||
cpqRackCommonEnclosureFruEnclosureName DisplayString,
|
||
cpqRackCommonEnclosureFruDescription DisplayString,
|
||
cpqRackCommonEnclosureFruLocation DisplayString,
|
||
cpqRackCommonEnclosureFruAssemblyPartNumber DisplayString,
|
||
cpqRackCommonEnclosureFruSparePartNumber DisplayString,
|
||
cpqRackCommonEnclosureFruAutoRev DisplayString,
|
||
cpqRackCommonEnclosureFruSerialNum DisplayString
|
||
}
|
||
|
||
cpqRackCommonEnclosureFruRack OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this rack."
|
||
::= { cpqRackCommonEnclosureFruEntry 1 }
|
||
|
||
cpqRackCommonEnclosureFruChassis OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this enclosure in the rack."
|
||
::= { cpqRackCommonEnclosureFruEntry 2 }
|
||
|
||
cpqRackCommonEnclosureFruIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies the FRU within this enclosure."
|
||
::= { cpqRackCommonEnclosureFruEntry 3 }
|
||
|
||
cpqRackCommonEnclosureFruEnclosureName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The name of the enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
name or it could not be determined."
|
||
::= { cpqRackCommonEnclosureFruEntry 4 }
|
||
|
||
cpqRackCommonEnclosureFruDescription OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A description of the FRU component.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
description information."
|
||
::= { cpqRackCommonEnclosureFruEntry 5 }
|
||
|
||
cpqRackCommonEnclosureFruLocation OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The location description of the FRU within the enclosure.
|
||
|
||
The string will be empty if the location could not be
|
||
determined."
|
||
::= { cpqRackCommonEnclosureFruEntry 6 }
|
||
|
||
cpqRackCommonEnclosureFruAssemblyPartNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The assembly part number of the FRU within the enclosure.
|
||
|
||
The string will be empty if the enclosure does not report this
|
||
information."
|
||
::= { cpqRackCommonEnclosureFruEntry 7 }
|
||
|
||
cpqRackCommonEnclosureFruSparePartNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The spare part number of the FRU within the enclosure.
|
||
|
||
The string will be empty if the enclosure does not report this
|
||
information."
|
||
::= { cpqRackCommonEnclosureFruEntry 8 }
|
||
|
||
cpqRackCommonEnclosureFruAutoRev OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The auto revision number of the FRU within the enclosure.
|
||
|
||
The string will be empty if the enclosure does not report this
|
||
information."
|
||
::= { cpqRackCommonEnclosureFruEntry 9 }
|
||
|
||
cpqRackCommonEnclosureFruSerialNum OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The serial number of the FRU within the enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
serial number."
|
||
::= { cpqRackCommonEnclosureFruEntry 10 }
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Enclosure Common Manager Table
|
||
-- ===================================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
|
||
-- cpqRackCommonEnclosure Group (1.3.6.1.4.1.232.22.2.3.1)
|
||
-- cpqRackCommonEnclosureManagerTable (1.3.6.1.4.1.232.22.2.3.1.6)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackCommonEnclosureManagerTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CpqRackCommonEnclosureManagerEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A table of rack enclosure manager information."
|
||
::= { cpqRackCommonEnclosure 6 }
|
||
|
||
cpqRackCommonEnclosureManagerEntry OBJECT-TYPE
|
||
SYNTAX CpqRackCommonEnclosureManagerEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A rack enclosure manager description."
|
||
INDEX { cpqRackCommonEnclosureManagerRack,
|
||
cpqRackCommonEnclosureManagerChassis,
|
||
cpqRackCommonEnclosureManagerIndex }
|
||
::= { cpqRackCommonEnclosureManagerTable 1 }
|
||
|
||
CpqRackCommonEnclosureManagerEntry ::= SEQUENCE {
|
||
cpqRackCommonEnclosureManagerRack INTEGER,
|
||
cpqRackCommonEnclosureManagerChassis INTEGER,
|
||
cpqRackCommonEnclosureManagerIndex INTEGER,
|
||
cpqRackCommonEnclosureManagerEnclosureName DisplayString,
|
||
cpqRackCommonEnclosureManagerLocation DisplayString,
|
||
cpqRackCommonEnclosureManagerPartNumber DisplayString,
|
||
cpqRackCommonEnclosureManagerSparePartNumber DisplayString,
|
||
cpqRackCommonEnclosureManagerSerialNum DisplayString,
|
||
cpqRackCommonEnclosureManagerRole INTEGER,
|
||
cpqRackCommonEnclosureManagerPresent INTEGER,
|
||
cpqRackCommonEnclosureManagerRedundant INTEGER,
|
||
cpqRackCommonEnclosureManagerCondition INTEGER,
|
||
cpqRackCommonEnclosureManagerEnclosureSerialNum DisplayString,
|
||
cpqRackCommonEnclosureManagerUUID DisplayString,
|
||
cpqRackCommonEnclosureManagerFWRev DisplayString
|
||
}
|
||
|
||
cpqRackCommonEnclosureManagerRack OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this rack."
|
||
::= { cpqRackCommonEnclosureManagerEntry 1 }
|
||
|
||
cpqRackCommonEnclosureManagerChassis OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this enclosure in the rack."
|
||
::= { cpqRackCommonEnclosureManagerEntry 2 }
|
||
|
||
cpqRackCommonEnclosureManagerIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this manager within this
|
||
enclosure in the rack."
|
||
::= { cpqRackCommonEnclosureManagerEntry 3 }
|
||
|
||
cpqRackCommonEnclosureManagerEnclosureName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The name of the enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
name or it could not be determined."
|
||
::= { cpqRackCommonEnclosureManagerEntry 4 }
|
||
|
||
cpqRackCommonEnclosureManagerLocation OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The location description of the manager within the enclosure.
|
||
|
||
The string will be empty if the location could not be
|
||
determined."
|
||
::= { cpqRackCommonEnclosureManagerEntry 5 }
|
||
|
||
cpqRackCommonEnclosureManagerPartNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The part number of the enclosure manager.
|
||
|
||
The string will be empty if the part number could not be
|
||
determined."
|
||
::= { cpqRackCommonEnclosureManagerEntry 6 }
|
||
|
||
cpqRackCommonEnclosureManagerSparePartNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The spare part number of the enclosure manager.
|
||
|
||
The string will be empty if the part number could not be
|
||
determined."
|
||
::= { cpqRackCommonEnclosureManagerEntry 7 }
|
||
|
||
cpqRackCommonEnclosureManagerSerialNum OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The serial number of the enclosure manager.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
serial number or it could not be determined."
|
||
::= { cpqRackCommonEnclosureManagerEntry 8 }
|
||
|
||
cpqRackCommonEnclosureManagerRole OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
standby(1),
|
||
active(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This specifies the current role of the manager."
|
||
::= { cpqRackCommonEnclosureManagerEntry 9 }
|
||
|
||
cpqRackCommonEnclosureManagerPresent OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
absent(2),
|
||
present(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This specifies if the manager described is present in the system."
|
||
::= { cpqRackCommonEnclosureManagerEntry 10 }
|
||
|
||
cpqRackCommonEnclosureManagerRedundant OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
notRedundant(2),
|
||
redundant(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This specifies if the manager is in a redundant configuration."
|
||
::= { cpqRackCommonEnclosureManagerEntry 11 }
|
||
|
||
cpqRackCommonEnclosureManagerCondition OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
ok(2),
|
||
degraded(3),
|
||
failed(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The condition of the manager.
|
||
|
||
This value will be one of the following:
|
||
|
||
other(1)
|
||
Manager status detection is not supported.
|
||
|
||
ok(2)
|
||
The manager is operating properly.
|
||
|
||
degraded(2)
|
||
A redundant manager is not operating properly.
|
||
|
||
failed(4)
|
||
A non-redundant manager is not operating properly."
|
||
::= { cpqRackCommonEnclosureManagerEntry 12 }
|
||
|
||
cpqRackCommonEnclosureManagerEnclosureSerialNum OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The serial number of the enclosure containing the manager.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
serial number or it could not be determined."
|
||
::= { cpqRackCommonEnclosureManagerEntry 13 }
|
||
|
||
cpqRackCommonEnclosureManagerUUID OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The universal unique identifier string of the manager.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
UUID string."
|
||
::= { cpqRackCommonEnclosureManagerEntry 14 }
|
||
|
||
cpqRackCommonEnclosureManagerFWRev OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The firmware revision of the enclosure manager.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
firmware revision or does not contain firmware."
|
||
::= { cpqRackCommonEnclosureManagerEntry 15 }
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Enclosure for Servers Table
|
||
-- ================================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
|
||
-- cpqRackServerEnclosure Group (1.3.6.1.4.1.232.22.2.3.2)
|
||
-- cpqRackServerEnclosureTable (1.3.6.1.4.1.232.22.2.3.2.1)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackServerEnclosureTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CpqRackServerEnclosureEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A table of rack enclosure information for servers."
|
||
::= { cpqRackServerEnclosure 1 }
|
||
|
||
cpqRackServerEnclosureEntry OBJECT-TYPE
|
||
SYNTAX CpqRackServerEnclosureEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A server enclosure description."
|
||
INDEX { cpqRackServerEnclosureRack,
|
||
cpqRackServerEnclosureIndex }
|
||
::= { cpqRackServerEnclosureTable 1 }
|
||
|
||
CpqRackServerEnclosureEntry ::= SEQUENCE {
|
||
cpqRackServerEnclosureRack INTEGER,
|
||
cpqRackServerEnclosureIndex INTEGER,
|
||
cpqRackServerEnclosureName DisplayString,
|
||
cpqRackServerEnclosureMaxNumBlades INTEGER,
|
||
cpqRackServerEnclosureMaxNumBladesX INTEGER,
|
||
cpqRackServerEnclosureMaxNumBladesY INTEGER,
|
||
cpqRackServerEnclosureSolutionsId OCTET STRING
|
||
}
|
||
|
||
cpqRackServerEnclosureRack OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this rack."
|
||
::= { cpqRackServerEnclosureEntry 1 }
|
||
|
||
cpqRackServerEnclosureIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this server enclosure in the rack."
|
||
::= { cpqRackServerEnclosureEntry 2 }
|
||
|
||
cpqRackServerEnclosureName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The name of the server enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
name or it could not be determined."
|
||
::= { cpqRackServerEnclosureEntry 3 }
|
||
|
||
cpqRackServerEnclosureMaxNumBlades OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The maximum number of server blades the enclosure can contain.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
name or it could not be determined."
|
||
::= { cpqRackServerEnclosureEntry 4 }
|
||
|
||
cpqRackServerEnclosureMaxNumBladesX OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The maximum number of server blades in x-direction (from left to right)
|
||
the enclosure can contain."
|
||
|
||
::= { cpqRackServerEnclosureEntry 5 }
|
||
|
||
cpqRackServerEnclosureMaxNumBladesY OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The maximum number of server blades in y-direction (from top to bottom)
|
||
the enclosure can contain."
|
||
|
||
::= { cpqRackServerEnclosureEntry 6 }
|
||
|
||
cpqRackServerEnclosureSolutionsId OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (8))
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The identifier is used to label enclosure as a BladeSystem Matrix enclosure.
|
||
Octet Values
|
||
===== ==============================
|
||
1 Solutions platform identifier
|
||
Bits[7:4]
|
||
- 0001b BladeSystem Matrix configured
|
||
- 0000b reserved
|
||
Bits[3:0]
|
||
- 0000b reserved
|
||
2 major number
|
||
- 0x01 - 0xff
|
||
3 minor number
|
||
- 0x01 - 0xff
|
||
4 update number
|
||
- 0x01 - 0xff
|
||
5 reserved/unused
|
||
|
||
The identifier is set to all 0's if the enclosure is
|
||
not configured as a BladeSystem Matrix enclosure."
|
||
|
||
::= { cpqRackServerEnclosureEntry 7 }
|
||
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Enclosure for Power Supplies Table
|
||
-- =======================================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
|
||
-- cpqRackPowerEnclosure Group (1.3.6.1.4.1.232.22.2.3.3)
|
||
-- cpqRackPowerEnclosureTable (1.3.6.1.4.1.232.22.2.3.3.1)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackPowerEnclosureTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CpqRackPowerEnclosureEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A table of rack power enclosure information."
|
||
::= { cpqRackPowerEnclosure 1 }
|
||
|
||
cpqRackPowerEnclosureEntry OBJECT-TYPE
|
||
SYNTAX CpqRackPowerEnclosureEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A rack power enclosure description."
|
||
INDEX { cpqRackPowerEnclosureRack,
|
||
cpqRackPowerEnclosureIndex }
|
||
::= { cpqRackPowerEnclosureTable 1 }
|
||
|
||
CpqRackPowerEnclosureEntry ::= SEQUENCE {
|
||
cpqRackPowerEnclosureRack INTEGER,
|
||
cpqRackPowerEnclosureIndex INTEGER,
|
||
cpqRackPowerEnclosureName DisplayString,
|
||
cpqRackPowerEnclosureMgmtBoardSerialNum DisplayString,
|
||
cpqRackPowerEnclosureRedundant INTEGER,
|
||
cpqRackPowerEnclosureLoadBalanced INTEGER,
|
||
cpqRackPowerEnclosureInputPwrType INTEGER,
|
||
cpqRackPowerEnclosurePwrFeedMax INTEGER,
|
||
cpqRackPowerEnclosureCondition INTEGER,
|
||
cpqRackPowerEnclosureBladeAutopoweron INTEGER
|
||
}
|
||
|
||
cpqRackPowerEnclosureRack OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this rack."
|
||
::= { cpqRackPowerEnclosureEntry 1 }
|
||
|
||
cpqRackPowerEnclosureIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this power enclosure in the rack."
|
||
::= { cpqRackPowerEnclosureEntry 2 }
|
||
|
||
cpqRackPowerEnclosureName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The name of the power enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
name or it could not be determined."
|
||
::= { cpqRackPowerEnclosureEntry 3 }
|
||
|
||
cpqRackPowerEnclosureMgmtBoardSerialNum OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The serial number of the enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
serial number."
|
||
::= { cpqRackPowerEnclosureEntry 4 }
|
||
|
||
cpqRackPowerEnclosureRedundant OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
notRedundant(2),
|
||
redundant(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This indicates if the power supply enclosure is in a redundant
|
||
state."
|
||
::= { cpqRackPowerEnclosureEntry 5 }
|
||
|
||
cpqRackPowerEnclosureLoadBalanced OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
notLoadBalanced(2),
|
||
loadBalanced(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This indicates if the power supply enclosure is in a load
|
||
balanced state."
|
||
::= { cpqRackPowerEnclosureEntry 6 }
|
||
|
||
cpqRackPowerEnclosureInputPwrType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
singlePhase(2),
|
||
threePhase(3),
|
||
directCurrent(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This indicates type of input facility power."
|
||
::= { cpqRackPowerEnclosureEntry 7 }
|
||
|
||
cpqRackPowerEnclosurePwrFeedMax OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This is the maximum facility power in watts.
|
||
|
||
The maximum facility power being fed to this power enclosure.
|
||
|
||
The value will be -1 if the power enclosure does not report the
|
||
value or if the value is not known."
|
||
::= { cpqRackPowerEnclosureEntry 8 }
|
||
|
||
cpqRackPowerEnclosureCondition OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
ok(2),
|
||
degraded(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This indicates current condition of the power enclosure.
|
||
|
||
other(1)
|
||
The power enclosure condition could not be determined.
|
||
|
||
ok(2)
|
||
The power enclosure is operating normally.
|
||
|
||
degraded(3)
|
||
The power enclosure is in a degraded state. The power subsystem
|
||
may not be load balanced or may have lost redundancy."
|
||
::= { cpqRackPowerEnclosureEntry 9 }
|
||
|
||
cpqRackPowerEnclosureBladeAutopoweron OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
disabled(2),
|
||
enabled(3)
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This indicates current condition of the power enclosure.
|
||
|
||
other(1)
|
||
The blade auto power on feature could not be determined.
|
||
|
||
disabled(2)
|
||
The enclosure will not automatically power on a blade when inserted.
|
||
|
||
enabled(3)
|
||
The enclosure will automatically power on a blade when inserted."
|
||
::= { cpqRackPowerEnclosureEntry 10 }
|
||
|
||
-- ****************************************************************************
|
||
-- The cpqRackLastEAEEvent holds data for last EAE event
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
|
||
-- cpqRackServerEnclosure Group (1.3.6.1.4.1.232.22.2.3.2)
|
||
-- cpqRackLastEAEEvent (1.3.6.1.4.1.232.22.2.3.2.2)
|
||
--
|
||
-- Implementation of this group is optional.
|
||
--
|
||
-- ****************************************************************************
|
||
cpqRackLastEAEEvent OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..512))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Data for the last EAE event."
|
||
--
|
||
-- This is the data variable that is sent with the generics EAE trap below.
|
||
--
|
||
::= { cpqRackServerEnclosure 2 }
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Server Blade Table
|
||
-- =======================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackServer Group (1.3.6.1.4.1.232.22.2.4)
|
||
-- cpqRackServerBlade Group (1.3.6.1.4.1.232.22.2.4.1)
|
||
-- cpqRackServerBladeTable (1.3.6.1.4.1.232.22.2.4.1.1)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackServerBladeTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CpqRackServerBladeEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A table of rack server blade information."
|
||
::= { cpqRackServerBlade 1 }
|
||
|
||
cpqRackServerBladeEntry OBJECT-TYPE
|
||
SYNTAX CpqRackServerBladeEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A rack server blade description."
|
||
INDEX { cpqRackServerBladeRack,
|
||
cpqRackServerBladeChassis,
|
||
cpqRackServerBladeIndex }
|
||
::= { cpqRackServerBladeTable 1 }
|
||
|
||
CpqRackServerBladeEntry ::= SEQUENCE {
|
||
cpqRackServerBladeRack INTEGER,
|
||
cpqRackServerBladeChassis INTEGER,
|
||
cpqRackServerBladeIndex INTEGER,
|
||
cpqRackServerBladeName DisplayString,
|
||
cpqRackServerBladeEnclosureName DisplayString,
|
||
cpqRackServerBladePartNumber DisplayString,
|
||
cpqRackServerBladeSparePartNumber DisplayString,
|
||
cpqRackServerBladePosition INTEGER,
|
||
cpqRackServerBladeHeight INTEGER,
|
||
cpqRackServerBladeWidth INTEGER,
|
||
cpqRackServerBladeDepth INTEGER,
|
||
cpqRackServerBladePresent INTEGER,
|
||
cpqRackServerBladeHasFuses INTEGER,
|
||
cpqRackServerBladeEnclosureSerialNum DisplayString,
|
||
cpqRackServerBladeSlotsUsed INTEGER,
|
||
cpqRackServerBladeSerialNum DisplayString,
|
||
cpqRackServerBladeProductId DisplayString,
|
||
cpqRackServerBladeUid DisplayString,
|
||
cpqRackServerBladeSlotsUsedX INTEGER,
|
||
cpqRackServerBladeSlotsUsedY INTEGER,
|
||
cpqRackServerBladeStatus INTEGER,
|
||
cpqRackServerBladeFaultMajor INTEGER,
|
||
cpqRackServerBladeFaultMinor INTEGER,
|
||
cpqRackServerBladeFaultDiagnosticString DisplayString,
|
||
cpqRackServerBladePowered INTEGER,
|
||
cpqRackServerBladeUIDState INTEGER,
|
||
cpqRackServerBladeSystemBIOSRevision DisplayString,
|
||
cpqRackServerBladeSystemBIOSFlashingStatus INTEGER,
|
||
cpqRackServerBladeHasManagementDevice INTEGER,
|
||
cpqRackServerBladeManagementDeviceFirmwareRevision DisplayString,
|
||
cpqRackServerBladeManagementDeviceFirmwareFlashingStatus INTEGER,
|
||
cpqRackServerBladeDiagnosticAdaptorPresence INTEGER,
|
||
cpqRackServerBladeASREnabled INTEGER,
|
||
cpqRackServerBladeFrontIOBlankingModeStatus INTEGER,
|
||
cpqRackServerBladePOSTStatus INTEGER,
|
||
cpqRackServerBladePXEBootModeStatus INTEGER,
|
||
cpqRackServerBladePendingBootOrderChange INTEGER,
|
||
cpqRackServerBladeWattageMax INTEGER,
|
||
cpqRackServerBladeWattageAvg INTEGER,
|
||
cpqRackServerBladeWattageMin INTEGER
|
||
}
|
||
|
||
cpqRackServerBladeRack OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this rack."
|
||
::= { cpqRackServerBladeEntry 1 }
|
||
|
||
cpqRackServerBladeChassis OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this enclosure in the rack."
|
||
::= { cpqRackServerBladeEntry 2 }
|
||
|
||
cpqRackServerBladeIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this server blade within the enclosure."
|
||
::= { cpqRackServerBladeEntry 3 }
|
||
|
||
cpqRackServerBladeName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The name of the server blade.
|
||
|
||
The string will be empty if it could not be determined."
|
||
::= { cpqRackServerBladeEntry 4 }
|
||
|
||
cpqRackServerBladeEnclosureName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The name of the enclosure which contains the blade.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
name or it could not be determined."
|
||
::= { cpqRackServerBladeEntry 5 }
|
||
|
||
cpqRackServerBladePartNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The part number of the server blade.
|
||
|
||
The string will be empty if the part number could not be
|
||
determined."
|
||
::= { cpqRackServerBladeEntry 6 }
|
||
|
||
cpqRackServerBladeSparePartNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The spare part number of the server blade.
|
||
|
||
The string will be empty if the part number could not be
|
||
determined."
|
||
::= { cpqRackServerBladeEntry 7 }
|
||
|
||
cpqRackServerBladePosition OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The position or slot number of the server blade within the
|
||
server enclosure.
|
||
|
||
This will be -1 if the server enclosure does not report the
|
||
information or it could not be determined."
|
||
::= { cpqRackServerBladeEntry 8 }
|
||
|
||
cpqRackServerBladeHeight OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The height dimension of the rack space taken by the server
|
||
blade expressed in millimeters.
|
||
|
||
This will be -1 if the rack does not report the information or
|
||
it could not be determined."
|
||
::= { cpqRackServerBladeEntry 9 }
|
||
|
||
cpqRackServerBladeWidth OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The width dimension of the rack space taken by the server
|
||
blade expressed in millimeters.
|
||
|
||
This will be -1 if the rack does not report the information or
|
||
it could not be determined."
|
||
::= { cpqRackServerBladeEntry 10 }
|
||
|
||
cpqRackServerBladeDepth OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The depth dimension of the rack space taken by the server
|
||
blade expressed in millimeters.
|
||
|
||
This will be -1 if the rack does not report the information or
|
||
it could not be determined."
|
||
::= { cpqRackServerBladeEntry 11 }
|
||
|
||
cpqRackServerBladePresent OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
absent(2),
|
||
present(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This specifies if the server blade described is present in the
|
||
enclosure."
|
||
::= { cpqRackServerBladeEntry 12 }
|
||
|
||
cpqRackServerBladeHasFuses OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
false(1),
|
||
true(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The server blade contains fuses.
|
||
|
||
This will be true(2) is the server blade contains fuses.
|
||
The cpqRackCommonEnclosureFuseTable will contain the fuse
|
||
specific information.
|
||
|
||
Match the cpqRackServerBladeEnclosureSerialNum in this table to the
|
||
serial number in the cpqRackCommonEnclosureFanTable to get complete
|
||
information on the fuses."
|
||
::= { cpqRackServerBladeEntry 13 }
|
||
|
||
cpqRackServerBladeEnclosureSerialNum OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The serial number of the enclosure which contains the blade.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
serial number or it could not be determined."
|
||
::= { cpqRackServerBladeEntry 14 }
|
||
|
||
cpqRackServerBladeSlotsUsed OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of slot positions occupied by this server blade. This
|
||
is used to indicate a server blade which may obscure an adjacent
|
||
blade slot.
|
||
|
||
This will be -1 if the rack does not report the information or
|
||
it could not be determined."
|
||
::= { cpqRackServerBladeEntry 15 }
|
||
|
||
cpqRackServerBladeSerialNum OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The serial number of the server blade.
|
||
|
||
The string will be empty if the system does not report the
|
||
serial number function."
|
||
::= { cpqRackServerBladeEntry 16 }
|
||
|
||
cpqRackServerBladeProductId OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The product id string of the server blade.
|
||
|
||
The string will be empty if the system does not report the
|
||
product id function."
|
||
::= { cpqRackServerBladeEntry 17 }
|
||
|
||
cpqRackServerBladeUid OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The server blade unique identifier (UUID).
|
||
|
||
The string will be empty if the blade does not report the
|
||
UUID or if it could not be determined."
|
||
::= { cpqRackServerBladeEntry 18 }
|
||
|
||
cpqRackServerBladeSlotsUsedX OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of slot positions in x-direction (from left to right)
|
||
occupied by this server blade. This is used to indicate a server blade
|
||
which may obscure an adjacent blade slot.
|
||
|
||
This will be -1 if the rack does not report the information or
|
||
it could not be determined."
|
||
::= { cpqRackServerBladeEntry 19 }
|
||
|
||
cpqRackServerBladeSlotsUsedY OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The number of slot positions in y-direction (from top to bottom)
|
||
occupied by this server blade. This is used to indicate a server blade
|
||
which may obscure an adjacent blade slot.
|
||
|
||
This will be -1 if the rack does not report the information or
|
||
it could not be determined."
|
||
::= { cpqRackServerBladeEntry 20 }
|
||
|
||
cpqRackServerBladeStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
ok(2),
|
||
degraded(3),
|
||
failed(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The health status of the blade.
|
||
|
||
This will be other(1) if the rack does not report the information
|
||
or if it could not be determined."
|
||
::= { cpqRackServerBladeEntry 21 }
|
||
|
||
cpqRackServerBladeFaultMajor OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The major fault code of the blade fault
|
||
reported by the enclosure manager.
|
||
|
||
This will be -1 if the rack does not report the information or
|
||
if it could not be determined."
|
||
::= { cpqRackServerBladeEntry 22 }
|
||
|
||
cpqRackServerBladeFaultMinor OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The minor fault code of the blade fault
|
||
reported by the enclosure manager.
|
||
|
||
This will be -1 if the rack does not report the information or
|
||
if it could not be determined."
|
||
::= { cpqRackServerBladeEntry 23 }
|
||
|
||
cpqRackServerBladeFaultDiagnosticString OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..128))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The server blade fault diagnostic string. This will contain a probable
|
||
cause and potential diagnostic action to be taken to remedy the fault condition.
|
||
|
||
The string will be empty if the blade does not report the
|
||
diagnostic string or if it could not be determined."
|
||
::= { cpqRackServerBladeEntry 24 }
|
||
|
||
cpqRackServerBladePowered OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
on(2),
|
||
off(3),
|
||
powerStagedOff(4),
|
||
reboot(5)
|
||
}
|
||
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The power state of the blade.
|
||
|
||
This will be other(1) if the rack does not report the information or if it could not be determined."
|
||
::= { cpqRackServerBladeEntry 25 }
|
||
|
||
cpqRackServerBladeUIDState OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1), -- Unknown device or could not be determined
|
||
none(2), -- No Unit Identifier LED present
|
||
ledOn(3), -- Unit Identifier LED is On
|
||
ledOff(4) -- Unit Identifier LED is Off
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The Unit Identifier LED.
|
||
|
||
This value will be one of the following:
|
||
|
||
other(1)
|
||
The state of the LED could not be determined. Setting the
|
||
LED state is not allowed.
|
||
|
||
none(2)
|
||
The LED is not present. Setting LED state is not allowed.
|
||
|
||
ledOn(3)
|
||
The LED is present and ON. The LED can be turned off
|
||
by setting the cpqRackServerBladeUIDState to ledOff(4).
|
||
|
||
ledOff(4)
|
||
The LED is present and OFF. The LED can be turned on
|
||
by setting the cpqRackServerBladeUIDState to ledOn(3).
|
||
"
|
||
::= { cpqRackServerBladeEntry 26 }
|
||
|
||
cpqRackServerBladeSystemBIOSRevision OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The server blade system bios revision.
|
||
|
||
The string will be empty if the blade does not report the
|
||
system bios revision or if it could not be determined."
|
||
::= { cpqRackServerBladeEntry 27 }
|
||
|
||
cpqRackServerBladeSystemBIOSFlashingStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1), -- Status Unknown or could not be determined
|
||
normal(2), -- Blade sytem BIOS not currently in flash mode
|
||
flashing(3) -- Blade sytem BIOS currently in flash mode
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Blade server system BIOS flashing / flash mode status indication.
|
||
|
||
This will be other(1) if the rack does not report the information or if it could not be determined."
|
||
::= { cpqRackServerBladeEntry 28 }
|
||
|
||
cpqRackServerBladeHasManagementDevice OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
false(1),
|
||
true(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The blade server contains one or more management devices.
|
||
|
||
This will be true(2) if the blade server contains managers and false (1) if not
|
||
or if it can't be detected."
|
||
::= { cpqRackServerBladeEntry 29 }
|
||
|
||
cpqRackServerBladeManagementDeviceFirmwareRevision OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The server blade management device firwmware revision.
|
||
|
||
The string will be empty if the blade does not report the
|
||
management device firwmware revision or if it could not be determined."
|
||
::= { cpqRackServerBladeEntry 30 }
|
||
|
||
cpqRackServerBladeManagementDeviceFirmwareFlashingStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1), -- Status Unknown or could not be determined
|
||
normal(2), -- Blade sytem management device not currently in flash mode
|
||
flashing(3) -- Blade sytem management device currently in flash mode
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Blade server management device firwmware flashing / flash mode status indication.
|
||
|
||
This will be other(1) if the rack does not report this information or if it could not be determined."
|
||
::= { cpqRackServerBladeEntry 31 }
|
||
|
||
cpqRackServerBladeDiagnosticAdaptorPresence OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
absent(2),
|
||
present(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This specifies if a blade diagnostic adaptor is currently plugged into the system."
|
||
::= { cpqRackServerBladeEntry 32 }
|
||
|
||
cpqRackServerBladeASREnabled OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
false(1),
|
||
true(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates whether the target blade server has Automatic Service Recovery feature enabled.
|
||
|
||
This will be true(2) if the blade server has this feature eanbled and false (1) if not
|
||
or if it can't be detected."
|
||
::= { cpqRackServerBladeEntry 33 }
|
||
|
||
cpqRackServerBladeFrontIOBlankingModeStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(1),
|
||
inactive(2),
|
||
active(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates whether the target blade server has the front IO ports blanking feature enabled.
|
||
|
||
This will be Active(3) if the blade server has this feature eanbled, Inactive (2) if not,
|
||
or Unknown(1) if it can't be determined."
|
||
::= { cpqRackServerBladeEntry 34 }
|
||
|
||
cpqRackServerBladePOSTStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1), -- POST Status Unknown or could not be determined
|
||
started(2), -- Blade has started Power-on-self-test (POST) process
|
||
completed(3), -- Blade has finished Power-on-self-test (POST) process
|
||
failed(4) -- Blade has failed to complete Power-on-self-test (POST) process and halted
|
||
}
|
||
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Blade server power-on self test (POST) status.
|
||
|
||
This value will be one of the following:
|
||
|
||
other(1)
|
||
The state of the blade POST could not be determined.
|
||
|
||
started(2)
|
||
Blade has started Power-on-self-test (POST) process.
|
||
|
||
completed(3)
|
||
Blade has finished Power-on-self-test (POST) process.
|
||
|
||
failed(4)
|
||
Blade has failed to complete Power-on-self-test (POST) process and halted.
|
||
|
||
This will be other(1) if the rack does not report this information or if it could not be determined."
|
||
::= { cpqRackServerBladeEntry 35 }
|
||
|
||
cpqRackServerBladePXEBootModeStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(1),
|
||
inactive(2),
|
||
active(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Indicates whether the target blade server is in PXE boot mode.
|
||
|
||
This will be Active(3) if the blade server has this feature enbled, Inactive (2) if not,
|
||
or Unknown(1) if it can't be determined."
|
||
::= { cpqRackServerBladeEntry 36 }
|
||
|
||
cpqRackServerBladePendingBootOrderChange OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1), --Unknown or cannot be determined
|
||
none(2), --No Changes
|
||
firstPXE(3), --Boot To Pre-Boot eXecution (PXE) First
|
||
firstHDD(4), --First Boot To Local HD
|
||
firstRBSU(5), --First Boot To ROM Based Setup Utility
|
||
oncePXE(6), --Boot To Pre-Boot eXecution (PXE) Once
|
||
onceHDD(7), --Boot To Local HD Once
|
||
onceRBSU(8), --Boot To ROM Based Setup Utility Once
|
||
alwaysPXE(9), --Always Boot To Pre-Boot eXecution (PXE)
|
||
alwaysHDD(10), --Always Boot To Local HD
|
||
alwaysRBSU(11) --Always Boot To ROM Based Setup Utility
|
||
}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Blade server pending boot order setting change state.
|
||
|
||
This value will be one of the following:
|
||
|
||
other(1) - Unknown or cannot be determined
|
||
none(2) - No Changes
|
||
firstPXE(3) - Boot To Pre-Boot eXecution (PXE) First
|
||
firstHDD(4) - First Boot To Local HD
|
||
firstRBSU(5) - First Boot To ROM Based Setup Utility
|
||
oncePXE(6) - Boot To Pre-Boot eXecution (PXE) Once
|
||
onceHDD(7) - Boot To Local HD Once
|
||
onceRBSU(8) - Boot To ROM Based Setup Utility Once
|
||
alwaysPXE(9) - Always Boot To Pre-Boot eXecution (PXE)
|
||
alwaysHDD(10) - Always Boot To Local HD
|
||
alwaysRBSU(11) - Always Boot To ROM Based Setup Utility
|
||
|
||
This will be other(1) if the rack does not report this information or if it could not be determined."
|
||
::= { cpqRackServerBladeEntry 37 }
|
||
|
||
cpqRackServerBladeWattageMax OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Maximum wattage the server has consumed during this power cycle."
|
||
::= { cpqRackServerBladeEntry 38 }
|
||
|
||
cpqRackServerBladeWattageAvg OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Average wattage the server is consuming, averaged over a period defined by the product."
|
||
::= { cpqRackServerBladeEntry 39 }
|
||
|
||
cpqRackServerBladeWattageMin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Minimum wattage the server has consumed, computed from a period defined by the product. Value
|
||
will be 0 if not supported, but other wattage values are supported."
|
||
::= { cpqRackServerBladeEntry 40 }
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Server Networking Table
|
||
-- =======================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackServer Group (1.3.6.1.4.1.232.22.2.4)
|
||
-- cpqRackServerNetworking Group (1.3.6.1.4.1.232.22.2.4.2)
|
||
-- cpqRackServerNetworkingTable (1.3.6.1.4.1.232.22.2.4.2.1)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackServerNetworkingTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CpqRackServerNetworkingEntry
|
||
ACCESS not-accessible
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A table of rack server networking information."
|
||
::= { cpqRackServerNetworking 1 }
|
||
|
||
cpqRackServerNetworkingEntry OBJECT-TYPE
|
||
SYNTAX CpqRackServerNetworkingEntry
|
||
ACCESS not-accessible
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A rack server networking description."
|
||
INDEX { cpqRackServerNetworkingRack,
|
||
cpqRackServerNetworkingChassis,
|
||
cpqRackServerNetworkingIndex }
|
||
::= { cpqRackServerNetworkingTable 1 }
|
||
|
||
CpqRackServerNetworkingEntry ::= SEQUENCE {
|
||
cpqRackServerNetworkingRack INTEGER,
|
||
cpqRackServerNetworkingChassis INTEGER,
|
||
cpqRackServerNetworkingIndex INTEGER,
|
||
cpqRackServerNetworkingName DisplayString,
|
||
cpqRackServerNetworkingEnclosureName DisplayString,
|
||
cpqRackServerNetworkingEthernetInterfaces INTEGER,
|
||
cpqRackServerNetworkingEthernetMACAddress DisplayString
|
||
}
|
||
|
||
cpqRackServerNetworkingRack OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this rack."
|
||
::= { cpqRackServerNetworkingEntry 1 }
|
||
|
||
cpqRackServerNetworkingChassis OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this enclosure in the rack."
|
||
::= { cpqRackServerNetworkingEntry 2 }
|
||
|
||
cpqRackServerNetworkingIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this server within the enclosure."
|
||
::= { cpqRackServerNetworkingEntry 3 }
|
||
|
||
cpqRackServerNetworkingName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The name of the server.
|
||
|
||
The string will be empty if it could not be determined."
|
||
::= { cpqRackServerNetworkingEntry 4 }
|
||
|
||
cpqRackServerNetworkingEnclosureName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The name of the enclosure which contains the server.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
name or if it could not be determined."
|
||
::= { cpqRackServerNetworkingEntry 5 }
|
||
|
||
cpqRackServerNetworkingEthernetInterfaces OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A number that specifies the amount of
|
||
Ethernet network interfaces in the server."
|
||
::= { cpqRackServerNetworkingEntry 6 }
|
||
|
||
cpqRackServerNetworkingEthernetMACAddress OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The MAC address for the Ethernet NIC populated in the server.
|
||
|
||
The string will be empty if it could not be determined."
|
||
::= { cpqRackServerNetworkingEntry 7 }
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Server Temperature Sensor Table
|
||
-- =======================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackServer Group (1.3.6.1.4.1.232.22.2.4)
|
||
-- cpqRackServerTempSensor Group (1.3.6.1.4.1.232.22.2.4.3)
|
||
-- cpqRackServerTempSensorTable (1.3.6.1.4.1.232.22.2.4.3.1)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackServerTempSensorTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CpqRackServerTempSensorEntry
|
||
ACCESS not-accessible
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A table of rack server temperature sensor information."
|
||
::= { cpqRackServerTempSensor 1 }
|
||
|
||
cpqRackServerTempSensorEntry OBJECT-TYPE
|
||
SYNTAX CpqRackServerTempSensorEntry
|
||
ACCESS not-accessible
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A rack server temperature sensor description."
|
||
INDEX { cpqRackServerTempSensorRack,
|
||
cpqRackServerTempSensorChassis,
|
||
cpqRackServerTempSensorIndex }
|
||
::= { cpqRackServerTempSensorTable 1 }
|
||
|
||
CpqRackServerTempSensorEntry ::= SEQUENCE {
|
||
cpqRackServerTempSensorRack INTEGER,
|
||
cpqRackServerTempSensorChassis INTEGER,
|
||
cpqRackServerTempSensorIndex INTEGER,
|
||
cpqRackServerTempSensorName DisplayString,
|
||
cpqRackServerTempSensorEnclosureName DisplayString,
|
||
cpqRackServerTempSensorCount INTEGER,
|
||
cpqRackServerTempSensorLocation DisplayString,
|
||
cpqRackServerTempSensorCurrent INTEGER,
|
||
cpqRackServerTempSensorThreshold INTEGER,
|
||
cpqRackServerTempSensorCondition INTEGER,
|
||
cpqRackServerTempSensorType INTEGER
|
||
}
|
||
|
||
cpqRackServerTempSensorRack OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this rack."
|
||
::= { cpqRackServerTempSensorEntry 1 }
|
||
|
||
cpqRackServerTempSensorChassis OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this enclosure in the rack."
|
||
::= { cpqRackServerTempSensorEntry 2 }
|
||
|
||
cpqRackServerTempSensorIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this server within the enclosure."
|
||
::= { cpqRackServerTempSensorEntry 3 }
|
||
|
||
cpqRackServerTempSensorName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The name of the server.
|
||
|
||
The string will be empty if it could not be determined."
|
||
::= { cpqRackServerTempSensorEntry 4 }
|
||
|
||
cpqRackServerTempSensorEnclosureName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The name of the enclosure which contains the server.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
name or if it could not be determined."
|
||
::= { cpqRackServerTempSensorEntry 5 }
|
||
|
||
cpqRackServerTempSensorCount OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A number that specifies the amount of
|
||
temperature sensors in the server."
|
||
::= { cpqRackServerTempSensorEntry 6 }
|
||
|
||
cpqRackServerTempSensorLocation OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The location description of the temperature sensor within the
|
||
blade server.
|
||
|
||
The string will be empty if it could not be determined."
|
||
::= { cpqRackServerTempSensorEntry 7 }
|
||
|
||
cpqRackServerTempSensorCurrent OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This is the current temperature sensor reading in degrees
|
||
celsius.
|
||
|
||
If this value cannot be determined by software, then a value
|
||
of -1 will be returned."
|
||
::= { cpqRackServerTempSensorEntry 8 }
|
||
|
||
cpqRackServerTempSensorThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This is the threshold temperature sensor setting
|
||
in degrees celsius. This is the temperature in which the
|
||
sensor will be considered to be in a tripped state this
|
||
causing some action to occur depending on the type of
|
||
the sensor. The action of temperature sensor threshold
|
||
will be indicated by the cpqRackServerTempSensorType
|
||
item. If the type is blowout(5), then the temperature sensor
|
||
will cause the fans to speed up. If the type is caution(9),
|
||
then the temperature sensor is in a degraded state. If the
|
||
type is critical(15), then the enclosure will be considered
|
||
as in a failed state.
|
||
|
||
If this value cannot be determined by software, then a value
|
||
of -1 will be returned."
|
||
::= { cpqRackServerTempSensorEntry 9 }
|
||
|
||
cpqRackServerTempSensorCondition OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
ok(2),
|
||
degraded(3),
|
||
failed(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The Temperature sensor condition.
|
||
|
||
This value will be one of the following:
|
||
|
||
other(1)
|
||
Temperature could not be determined.
|
||
|
||
ok(2)
|
||
The temperature sensor is within the normal operating range.
|
||
|
||
degraded(3)
|
||
The temperature sensor is outside of the normal operating range.
|
||
|
||
failed(4)
|
||
The temperature sensor detects a condition that could
|
||
possibly overheat the system.
|
||
|
||
The system will automatically shutdown if the failed(4) condition
|
||
results, so it is unlikely that this value will ever be returned
|
||
by the agent."
|
||
::= { cpqRackServerTempSensorEntry 10 }
|
||
|
||
cpqRackServerTempSensorType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
blowout(5),
|
||
caution(9),
|
||
critical(15)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This specifies the type of this instance of temperature
|
||
sensor.
|
||
|
||
This value will be one of the following:
|
||
|
||
other(1)
|
||
Temperature threshold type could not be determined.
|
||
|
||
blowout(5)
|
||
If a blowout(5) temperature sensor reaches its threshold,
|
||
the fan or fans in the area of the temperature sensor will
|
||
increase in speed in an attempt to reduce the temperature
|
||
before a caution or critical threshold is reached.
|
||
|
||
caution(9)
|
||
If a caution(9) temperature sensor reaches its threshold, the
|
||
cpqRackServerTempSensorCondition will be set to degraded(3)
|
||
and the system will either continue or shutdown depending
|
||
on the local blade server policy settings.
|
||
|
||
critical(15)
|
||
If a critical(15) temperature sensor reaches its threshold,
|
||
cpqRackServerTempSensorCondition will be set to failed(4)
|
||
and the blade server will shutdown."
|
||
::= { cpqRackServerTempSensorEntry 11 }
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Power Supply Table
|
||
-- =======================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackPower Group (1.3.6.1.4.1.232.22.2.5)
|
||
-- cpqRackPowerSupply Group (1.3.6.1.4.1.232.22.2.5.1)
|
||
-- cpqRackPowerSupplyTable (1.3.6.1.4.1.232.22.2.5.1.1)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackPowerSupplyTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CpqRackPowerSupplyEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A table of rack power supply information."
|
||
::= { cpqRackPowerSupply 1 }
|
||
|
||
cpqRackPowerSupplyEntry OBJECT-TYPE
|
||
SYNTAX CpqRackPowerSupplyEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A rack power supply description."
|
||
INDEX { cpqRackPowerSupplyRack,
|
||
cpqRackPowerSupplyChassis,
|
||
cpqRackPowerSupplyIndex }
|
||
::= { cpqRackPowerSupplyTable 1 }
|
||
|
||
CpqRackPowerSupplyEntry ::= SEQUENCE {
|
||
cpqRackPowerSupplyRack INTEGER,
|
||
cpqRackPowerSupplyChassis INTEGER,
|
||
cpqRackPowerSupplyIndex INTEGER,
|
||
cpqRackPowerSupplyEnclosureName DisplayString,
|
||
cpqRackPowerSupplySerialNum DisplayString,
|
||
cpqRackPowerSupplyPartNumber DisplayString,
|
||
cpqRackPowerSupplySparePartNumber DisplayString,
|
||
cpqRackPowerSupplyFWRev DisplayString,
|
||
cpqRackPowerSupplyMaxPwrOutput INTEGER,
|
||
cpqRackPowerSupplyCurPwrOutput INTEGER,
|
||
cpqRackPowerSupplyPosition INTEGER,
|
||
cpqRackPowerSupplyIntakeTemp INTEGER,
|
||
cpqRackPowerSupplyExhaustTemp INTEGER,
|
||
cpqRackPowerSupplyStatus INTEGER,
|
||
cpqRackPowerSupplyInputLineStatus INTEGER,
|
||
cpqRackPowerSupplyPresent INTEGER,
|
||
cpqRackPowerSupplyCondition INTEGER,
|
||
cpqRackPowerSupplyEnclosureSerialNum DisplayString
|
||
}
|
||
|
||
cpqRackPowerSupplyRack OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this rack."
|
||
::= { cpqRackPowerSupplyEntry 1 }
|
||
|
||
cpqRackPowerSupplyChassis OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this power enclosure in the rack."
|
||
::= { cpqRackPowerSupplyEntry 2 }
|
||
|
||
cpqRackPowerSupplyIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this power supply in the enclosure."
|
||
::= { cpqRackPowerSupplyEntry 3 }
|
||
|
||
cpqRackPowerSupplyEnclosureName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The name of the power supply enclosure in which this power supply
|
||
resides.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
name or it could not be determined."
|
||
::= { cpqRackPowerSupplyEntry 4 }
|
||
|
||
cpqRackPowerSupplySerialNum OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The serial number of the power supply.
|
||
|
||
The string will be empty if the power supply does not report the
|
||
serial number."
|
||
::= { cpqRackPowerSupplyEntry 5 }
|
||
|
||
cpqRackPowerSupplyPartNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The part number of the power supply.
|
||
|
||
The string will be empty if the power supply does not report this
|
||
function."
|
||
::= { cpqRackPowerSupplyEntry 6 }
|
||
|
||
cpqRackPowerSupplySparePartNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The spare part number of the power supply.
|
||
|
||
The string will be empty if the power supply does not report this
|
||
function."
|
||
::= { cpqRackPowerSupplyEntry 7 }
|
||
|
||
cpqRackPowerSupplyFWRev OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The firmware revision of the power supply.
|
||
|
||
The string will be empty if the power supply does not report the
|
||
firmware revision."
|
||
::= { cpqRackPowerSupplyEntry 8 }
|
||
|
||
cpqRackPowerSupplyMaxPwrOutput OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The maximum power output of the power supply in watts.
|
||
|
||
The value will be -1 if the power supply does not report the
|
||
value."
|
||
::= { cpqRackPowerSupplyEntry 9 }
|
||
|
||
cpqRackPowerSupplyCurPwrOutput OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The current power output of the power supply in watts.
|
||
|
||
The value will be -1 if the power supply does not report the
|
||
value."
|
||
::= { cpqRackPowerSupplyEntry 10 }
|
||
|
||
cpqRackPowerSupplyPosition OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The position of the power supply within the power enclosure.
|
||
|
||
This will be -1 if the power enclosure does not report the
|
||
power supply information or it could not be determined."
|
||
::= { cpqRackPowerSupplyEntry 11 }
|
||
|
||
cpqRackPowerSupplyIntakeTemp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The current air temperature at the intake of the power supply
|
||
in degrees celsius.
|
||
|
||
The value will be -1 if the power supply does not report the
|
||
value."
|
||
::= { cpqRackPowerSupplyEntry 12 }
|
||
|
||
cpqRackPowerSupplyExhaustTemp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The current air temperature at the exhaust of the power supply
|
||
in degrees celsius.
|
||
|
||
The value will be -1 if the power supply does not report the
|
||
value."
|
||
::= { cpqRackPowerSupplyEntry 13 }
|
||
|
||
cpqRackPowerSupplyStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
noError(1),
|
||
generalFailure(2),
|
||
bistFailure(3),
|
||
fanFailure(4),
|
||
tempFailure(5),
|
||
interlockOpen(6),
|
||
epromFailed(7),
|
||
vrefFailed(8),
|
||
dacFailed(9),
|
||
ramTestFailed(10),
|
||
voltageChannelFailed(11),
|
||
orringdiodeFailed(12),
|
||
brownOut(13),
|
||
giveupOnStartup(14),
|
||
nvramInvalid(15),
|
||
calibrationTableInvalid(16)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The status of the power supply."
|
||
::= { cpqRackPowerSupplyEntry 14 }
|
||
|
||
cpqRackPowerSupplyInputLineStatus OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
noError(1),
|
||
lineOverVoltage(2),
|
||
lineUnderVoltage(3),
|
||
lineHit(4),
|
||
brownOut(5),
|
||
linePowerLoss(6)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The status of line input power."
|
||
::= { cpqRackPowerSupplyEntry 15 }
|
||
|
||
cpqRackPowerSupplyPresent OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
absent(2),
|
||
present(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This specifies if the power supply described is present in the
|
||
enclosure."
|
||
::= { cpqRackPowerSupplyEntry 16 }
|
||
|
||
cpqRackPowerSupplyCondition OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
ok(2),
|
||
degraded(3),
|
||
failed(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The condition of the power supply.
|
||
|
||
This value will be one of the following:
|
||
|
||
other(1)
|
||
The status could not be determined or not present.
|
||
|
||
ok(2)
|
||
The power supply is operating normally.
|
||
|
||
degraded(3)
|
||
A temperature sensor, fan or other power supply component is
|
||
outside of normal operating range.
|
||
|
||
failed(4)
|
||
A power supply component detects a condition that could
|
||
possibly damage the system."
|
||
::= { cpqRackPowerSupplyEntry 17 }
|
||
|
||
cpqRackPowerSupplyEnclosureSerialNum OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The serial number of the power supply enclosure in which this
|
||
power supply resides.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
serial number or it could not be determined."
|
||
::= { cpqRackPowerSupplyEntry 18 }
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Network
|
||
-- ============
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackNetwork Group (1.3.6.1.4.1.232.22.2.6)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackNetworkAddressesTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CpqRackNetworkAddressesEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A table of rack network addresses."
|
||
::= { cpqRackNetwork 2}
|
||
|
||
cpqRackNetworkAddressesEntry OBJECT-TYPE
|
||
SYNTAX CpqRackNetworkAddressesEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Array of ALL the network addresses of the system generating the indication.
|
||
|
||
This may include IPv4 addresses (based on IETF RFC 1208) or IPv6 addresses
|
||
(based on IETF RFC 4291)."
|
||
INDEX { cpqRackNetworkAddresses }
|
||
::= { cpqRackNetworkAddressesTable 1}
|
||
|
||
CpqRackNetworkAddressesEntry ::= SEQUENCE {
|
||
cpqRackNetworkAddresses DisplayString
|
||
}
|
||
|
||
cpqRackNetworkAddresses OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..50))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A network address of the system generating the indication."
|
||
::= { cpqRackNetworkAddressesEntry 1}
|
||
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Network Connector Table
|
||
-- ============================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackNetwork Group (1.3.6.1.4.1.232.22.2.6)
|
||
-- cpqRackNetConnector Group (1.3.6.1.4.1.232.22.2.6.1)
|
||
-- cpqRackNetConnectorTable (1.3.6.1.4.1.232.22.2.6.1.1)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackNetConnectorTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CpqRackNetConnectorEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A table of rack network connector information."
|
||
::= { cpqRackNetConnector 1 }
|
||
|
||
cpqRackNetConnectorEntry OBJECT-TYPE
|
||
SYNTAX CpqRackNetConnectorEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A rack network connector description."
|
||
INDEX { cpqRackNetConnectorRack,
|
||
cpqRackNetConnectorChassis,
|
||
cpqRackNetConnectorIndex }
|
||
::= { cpqRackNetConnectorTable 1 }
|
||
|
||
CpqRackNetConnectorEntry ::= SEQUENCE {
|
||
cpqRackNetConnectorRack INTEGER,
|
||
cpqRackNetConnectorChassis INTEGER,
|
||
cpqRackNetConnectorIndex INTEGER,
|
||
cpqRackNetConnectorEnclosureName DisplayString,
|
||
cpqRackNetConnectorName DisplayString,
|
||
cpqRackNetConnectorModel DisplayString,
|
||
cpqRackNetConnectorSerialNum DisplayString,
|
||
cpqRackNetConnectorPartNumber DisplayString,
|
||
cpqRackNetConnectorSparePartNumber DisplayString,
|
||
cpqRackNetConnectorFWRev DisplayString,
|
||
cpqRackNetConnectorType INTEGER,
|
||
cpqRackNetConnectorLocation DisplayString,
|
||
cpqRackNetConnectorPresent INTEGER,
|
||
cpqRackNetConnectorHasFuses INTEGER,
|
||
cpqRackNetConnectorEnclosureSerialNum DisplayString,
|
||
cpqRackNetConnectorTechnologyType INTEGER,
|
||
cpqRackNetConnectorDeviceType INTEGER
|
||
}
|
||
|
||
cpqRackNetConnectorRack OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this rack."
|
||
::= { cpqRackNetConnectorEntry 1 }
|
||
|
||
cpqRackNetConnectorChassis OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this server enclosure in the rack."
|
||
::= { cpqRackNetConnectorEntry 2 }
|
||
|
||
cpqRackNetConnectorIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"A number that uniquely specifies this network connector in the rack."
|
||
::= { cpqRackNetConnectorEntry 3 }
|
||
|
||
cpqRackNetConnectorEnclosureName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The name of the network connector enclosure.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
name or it could not be determined."
|
||
::= { cpqRackNetConnectorEntry 4 }
|
||
|
||
cpqRackNetConnectorName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The name of the network connector.
|
||
|
||
The string will be empty if the network connector does not report the
|
||
name or it could not be determined."
|
||
::= { cpqRackNetConnectorEntry 5 }
|
||
|
||
cpqRackNetConnectorModel OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The model name of the network connector.
|
||
|
||
The string will be empty if the network connector does not report the
|
||
model information."
|
||
::= { cpqRackNetConnectorEntry 6 }
|
||
|
||
cpqRackNetConnectorSerialNum OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The serial number of the network connector.
|
||
|
||
The string will be empty if the network connector does not report the
|
||
serial number."
|
||
::= { cpqRackNetConnectorEntry 7 }
|
||
|
||
cpqRackNetConnectorPartNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The part number of the network connector.
|
||
|
||
The string will be empty if the enclosure does not report this
|
||
function."
|
||
::= { cpqRackNetConnectorEntry 8 }
|
||
|
||
cpqRackNetConnectorSparePartNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The spare part number of the network connector.
|
||
|
||
The string will be empty if the enclosure does not report this
|
||
function."
|
||
::= { cpqRackNetConnectorEntry 9 }
|
||
|
||
cpqRackNetConnectorFWRev OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The firmware revision of the network connector.
|
||
|
||
The string will be empty if the network connector does not report the
|
||
firmware revision."
|
||
::= { cpqRackNetConnectorEntry 10 }
|
||
|
||
cpqRackNetConnectorType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
passive(2),
|
||
active(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The type of network connector within the enclosure."
|
||
::= { cpqRackNetConnectorEntry 11 }
|
||
|
||
cpqRackNetConnectorLocation OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The location of the network connector within the enclosure."
|
||
::= { cpqRackNetConnectorEntry 12 }
|
||
|
||
cpqRackNetConnectorPresent OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
absent(2),
|
||
present(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"This specifies if the network connector described is present in the
|
||
enclosure."
|
||
::= { cpqRackNetConnectorEntry 13 }
|
||
|
||
cpqRackNetConnectorHasFuses OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
false(1),
|
||
true(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The network connector contains fuses.
|
||
|
||
This will be true(2) is the network connector contains fuses.
|
||
The cpqRackCommonEnclosureFuseTable will contain the fuse
|
||
specific information.
|
||
|
||
Match the cpqRackNetworkEnclosureSerialNum in this table to the
|
||
serial number in the cpqRackCommonEnclosureFusTable to get complete
|
||
information on the fuses."
|
||
::= { cpqRackNetConnectorEntry 14 }
|
||
|
||
cpqRackNetConnectorEnclosureSerialNum OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The serial number of the enclosure containing the network connector.
|
||
|
||
The string will be empty if the enclosure does not report the
|
||
serial number or it could not be determined."
|
||
::= { cpqRackNetConnectorEntry 15 }
|
||
|
||
cpqRackNetConnectorTechnologyType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
other(1),
|
||
passive(2),
|
||
active(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The type of network connector within the enclosure."
|
||
::= { cpqRackNetConnectorEntry 16 }
|
||
|
||
cpqRackNetConnectorDeviceType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
noconnect(1),
|
||
network(2),
|
||
fibrechannel(3),
|
||
sas(4),
|
||
inifiband(5),
|
||
pciexpress(6)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The type of interrconnect in the enclosure.
|
||
|
||
This will be -1 if it is not reported or can not be deteremined."
|
||
::= { cpqRackNetConnectorEntry 17 }
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Hardware Information
|
||
-- =========================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackHW Group (1.3.6.1.4.1.232.22.2.7)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackHWPartNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..16))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Part number for the hardware generating the indication."
|
||
::= { cpqRackHW 1 }
|
||
|
||
cpqRackHWFirmwareVersionTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CpqRackHWFirmwareVersionEntry
|
||
ACCESS not-accessible
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A table of rack firmware versions."
|
||
::= { cpqRackHW 2 }
|
||
|
||
cpqRackHWFirmwareVersionEntry OBJECT-TYPE
|
||
SYNTAX CpqRackHWFirmwareVersionEntry
|
||
ACCESS not-accessible
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Array of versions of firmware for the hardware associated with the indication."
|
||
INDEX { cpqRackHWFirmwareVersion }
|
||
::= { cpqRackHWFirmwareVersionTable 1 }
|
||
|
||
CpqRackHWFirmwareVersionEntry ::= SEQUENCE {
|
||
cpqRackHWFirmwareVersion DisplayString
|
||
}
|
||
|
||
cpqRackHWFirmwareVersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..30))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A version of firmware for the hardware associated with the indication."
|
||
::= { cpqRackHWFirmwareVersionEntry 1 }
|
||
|
||
cpqRackHWManufacturer OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..65))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Manufacturer of the hardware associated with the indication.Device indication
|
||
hardware manufacturer."
|
||
::= { cpqRackHW 3 }
|
||
|
||
cpqRackHWSerialNumberTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CpqRackHWSerialNumberEntry
|
||
ACCESS not-accessible
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A table of rack hardware serial numbers."
|
||
::= { cpqRackHW 4 }
|
||
|
||
cpqRackHWSerialNumberEntry OBJECT-TYPE
|
||
SYNTAX CpqRackHWSerialNumberEntry
|
||
ACCESS not-accessible
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Array of all the serial numbers of the hardware associated with the indication."
|
||
INDEX { cpqRackHWSerialNumber }
|
||
::= { cpqRackHWSerialNumberTable 1 }
|
||
|
||
CpqRackHWSerialNumberEntry ::= SEQUENCE {
|
||
cpqRackHWSerialNumber DisplayString
|
||
}
|
||
|
||
cpqRackHWSerialNumber OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..21))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A serial number of the hardware associated with the indication."
|
||
::= { cpqRackHWSerialNumberEntry 1 }
|
||
|
||
cpqRackHWFRUDetails OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..256))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"This is used to provide miscellaneous FRU specific details
|
||
|
||
Some examples are DIMM size, Processor stepping info etc."
|
||
::= { cpqRackHW 5 }
|
||
|
||
cpqRackHWDevicePermanentNameFormat OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(1),
|
||
other(2),
|
||
worldWideName(3),
|
||
macAddress(4)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The format of the DevicePermanentName property is interpreted based upon
|
||
the value of this property.
|
||
|
||
Values are defined as:
|
||
1 - unknown. The format is not meaningfully interpretable by a CIM client
|
||
application.
|
||
2 - other. The format is defined by the value of the OtherPermanentNameFormat
|
||
property.
|
||
3 - worldWideName. The format is a WorldWideName.
|
||
4 - macAddress. The format is a LAN MAC Address."
|
||
::= { cpqRackHW 6 }
|
||
|
||
cpqRackHWOtherPermanentNameFormat OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A string defining other values for DevicePermanentFormat.
|
||
|
||
It is empty unless DevicePermanentFormat value is other."
|
||
::= { cpqRackHW 7 }
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Ers Information
|
||
-- =========================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
||
-- cpqRackErs Group (1.3.6.1.4.1.232.22.2.8)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackErsTransactionType OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
registration(1),
|
||
serviceEvent(2),
|
||
l2DataCollection(3),
|
||
unregistration(4)
|
||
}
|
||
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Embedded Remote Support transaction type.
|
||
|
||
The following values are defined:
|
||
|
||
registration(1)
|
||
Registration operation with Insight Remote Host or Insight Online Host.
|
||
|
||
serviceEvent(2)
|
||
Sending of service event to Insight Remote Host or Insight Online Host.
|
||
|
||
l2DataCollection(3)
|
||
L2 Data collection operation.
|
||
|
||
unregistration(4)
|
||
Unregistration with Insight Remote Host or Insight Online Host."
|
||
::= { cpqRackErs 1 }
|
||
|
||
cpqRackErsConnectionModel OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
insightOnline(1),
|
||
insightRemoteSupport(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Embedded Remote Support connection model configured on the Onboard Administrator."
|
||
::= { cpqRackErs 2 }
|
||
|
||
cpqRackErsFailureCode OBJECT-TYPE
|
||
SYNTAX INTEGER{
|
||
genericTransmitError(1),
|
||
clientTransmitTimeout(2),
|
||
clientReceiveTimeout(3),
|
||
proxyConnectError(4),
|
||
remoteHostConnectError(5),
|
||
remoteServiceError(6)
|
||
}
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Embedded Remote Support transaction failure code."
|
||
::= { cpqRackErs 3 }
|
||
|
||
cpqRackErsRemoteHost OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE (0..135))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"Remote destination server's hostname and port as configured on the Onboard Administrator.
|
||
|
||
Example: myremotehost.hpe.com:6789"
|
||
::= { cpqRackErs 4 }
|
||
|
||
-- ****************************************************************************
|
||
-- Rack System Object Identification
|
||
-- =================================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackSysObjID Group (1.3.6.1.4.1.232.22.3)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackSystemObjectIdentification OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The hardware identification string.
|
||
|
||
The string will reported by the rack firmware."
|
||
::= { cpqRackSysObjID 1 }
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Event Information
|
||
-- =================================
|
||
--
|
||
-- The compaq enterprise (1.3.6.1.4.1.232)
|
||
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
||
-- cpqRackEventInfo Group (1.3.6.1.4.1.232.22.4)
|
||
--
|
||
-- ****************************************************************************
|
||
|
||
cpqRackEventIndicationIdentifier OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..25))
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"The Event Indication Identifier."
|
||
::= { cpqRackEventInfo 1 }
|
||
|
||
cpqRackEventIndicationTime OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..33))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The Event Indication Time."
|
||
::= { cpqRackEventInfo 2 }
|
||
|
||
cpqRackEventDescription OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..1024))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The Event Description."
|
||
::= { cpqRackEventInfo 3 }
|
||
|
||
cpqRackEventSummary OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..255))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Short description of the reason for the event."
|
||
::= { cpqRackEventInfo 4 }
|
||
|
||
cpqRackEventCategory OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(1),
|
||
other(2),
|
||
processor(3),
|
||
memory(4),
|
||
systemHardware(5),
|
||
supportHardware(6),
|
||
primaryStorageDevice(7),
|
||
secondaryStorageDevice(8),
|
||
otherStorageDevice(9),
|
||
networkDevice(10),
|
||
otherDevice(11),
|
||
ioAdapter(12),
|
||
networkAdapter(13),
|
||
otherAdapter(14),
|
||
processorPower(15),
|
||
memoryPower(16),
|
||
systemPower(17),
|
||
primaryStorageDevicePower(18),
|
||
secondaryStoragePower(19),
|
||
otherStoragePower(20),
|
||
otherPower(21),
|
||
processorCooling(22),
|
||
memoryCooling(23),
|
||
systemCooling(24),
|
||
primaryStorageDeviceCooling(25),
|
||
secondaryStorageDeviceCooling(26),
|
||
otherStorageDeviceCooling(27),
|
||
otherCooling(28),
|
||
systemHWSecurity(29),
|
||
primaryStorageDeviceSecurity(30),
|
||
secondaryStorageDeviceSecurity(31),
|
||
otherStorageDeviceSecurity(32),
|
||
otherHWSecurity(33),
|
||
systemInterconnect(34),
|
||
supportInterconnect(35),
|
||
clusterInterconnect(36),
|
||
storageInterconnect(37),
|
||
networkInterconnect(38),
|
||
otherInterconnect(39),
|
||
os(40),
|
||
systemFirmware(41),
|
||
deviceFirmware(42),
|
||
supportFirmware(43),
|
||
systemFirmwareSecurity(44),
|
||
osSecurity(45),
|
||
softwareApplication(46),
|
||
softwareApplicationSecurity(47),
|
||
nonStopIncident(48)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Category for the event.
|
||
|
||
This category is intended to be used by the consumer to group events."
|
||
::= { cpqRackEventInfo 5 }
|
||
|
||
cpqRackOtherEventCategory OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A string defining other values for EventCategory.
|
||
|
||
It is empty unless EventCategory value is other(1)."
|
||
::= { cpqRackEventInfo 6 }
|
||
|
||
cpqRackEventSubCategory OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Sub-category for the event.
|
||
|
||
This sub-category is intended to be used by the consumer in conjunction
|
||
with the EventCategory to provide additional granularity to group events.
|
||
It is expected that additional values will be added that can be used with
|
||
other EventCategory values."
|
||
::= { cpqRackEventInfo 7 }
|
||
|
||
cpqRackOtherEventSubCategory OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A string defining other values for EventSubCategory.
|
||
|
||
It is empty unless EventSubCategory value is other(1)"
|
||
::= { cpqRackEventInfo 8 }
|
||
|
||
cpqRackEventThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Identifies the number of indications that need to occur as part of the
|
||
internal provider throttling configured for this event."
|
||
::= { cpqRackEventInfo 9 }
|
||
|
||
cpqRackEventTimeWin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Identifies the time window during which the EventThreshold number of events
|
||
need to occur as part of the internal provider throttling configured for
|
||
this event.
|
||
|
||
Time is in minutes. 0 means any amount of time."
|
||
::= { cpqRackEventInfo 10 }
|
||
|
||
cpqRackEventActualThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Identifies the number of indications that have occurred to meet the
|
||
internal provider throttling configured for this event."
|
||
::= { cpqRackEventInfo 11 }
|
||
|
||
cpqRackEventActualTimeWin OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Identifies the time window during which the ActualEventThreshold number
|
||
of events have occurred to meet the internal provider throttling configured
|
||
for this event.
|
||
|
||
Time is in minutes. 0 means any amount of time."
|
||
::= { cpqRackEventInfo 12 }
|
||
|
||
cpqRackEventProviderVersion OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..31))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The version of the provider generating this indication."
|
||
::= { cpqRackEventInfo 13 }
|
||
|
||
cpqRackEventAlertingElementFormat OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(1),
|
||
other(2),
|
||
cimObjectPath(3)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The format of the AlertingManagedElement property is interpretable based
|
||
upon the value of this property.
|
||
|
||
Values are defined as:
|
||
1 - unknown. The format is unknown or not meaningfully interpretable by a
|
||
CIM client application.
|
||
2 - other. The format is defined by the value of the OtherAlertingElementFormat
|
||
property.
|
||
3 - cimObjectPath. The format is a CIMObjectPath, specifying an instance in
|
||
the CIM Schema."
|
||
::= { cpqRackEventInfo 14 }
|
||
|
||
cpqRackEventOtherAlertingElementFormat OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE (0..256))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A string defining other values for AlertingElementFormat.
|
||
|
||
It is empty unless cpqRackEventAlertingElementFormat value is other(1)"
|
||
::= { cpqRackEventInfo 15 }
|
||
|
||
cpqRackEventImpactedDomain OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(1),
|
||
cluster(2),
|
||
complex(3),
|
||
enclosure(4),
|
||
system(5),
|
||
partition(6)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"ImpactedDomain is an enumerated value indicating the domain this event
|
||
affects."
|
||
::= { cpqRackEventInfo 16 }
|
||
|
||
cpqRackEventComplexName OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The name of the complex."
|
||
::= { cpqRackEventInfo 17 }
|
||
|
||
cpqRackEventPartitionId OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (0..12))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The Unique Identifier for the Partition.
|
||
|
||
The format of the partitionId will be of the form nparId:vparId."
|
||
::= { cpqRackEventInfo 18 }
|
||
|
||
cpqRackEventTriggeringLogIDTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF CpqRackEventTriggeringLogIDEntry
|
||
ACCESS not-accessible
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A table of rack of Low Level LOG IDs."
|
||
::= { cpqRackEventInfo 19 }
|
||
|
||
cpqRackEventTriggeringLogIDEntry OBJECT-TYPE
|
||
SYNTAX CpqRackEventTriggeringLogIDEntry
|
||
ACCESS not-accessible
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The list of Low level LOG ID which were used to generate this event.
|
||
|
||
The format of the value contained in this array is defined using the
|
||
TriggeringLogIDFormat field."
|
||
INDEX { cpqRackEventTriggeringLogID }
|
||
::= { cpqRackEventTriggeringLogIDTable 1 }
|
||
|
||
CpqRackEventTriggeringLogIDEntry ::= SEQUENCE {
|
||
cpqRackEventTriggeringLogID OCTET STRING
|
||
}
|
||
|
||
cpqRackEventTriggeringLogID OBJECT-TYPE
|
||
SYNTAX OCTET STRING (SIZE (0..256))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A Low Lvevel LOG ID which were used to generate this event."
|
||
::= {cpqRackEventTriggeringLogIDEntry 1 }
|
||
|
||
|
||
cpqRackEventTriggeringLogIDFormat OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknown(1),
|
||
cimObjectPath(2)
|
||
}
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The format of the TriggeringLogID property which interpretable based upon
|
||
the value of this property.
|
||
|
||
Values are defined as:
|
||
1 - unknown. The format is unknown or not meaningfully interpretable by a
|
||
CIM client application.
|
||
2 - cimObjectPath. The format is a CIMObjectPath, with format specifying an
|
||
instance in the CIM Schema."
|
||
::= { cpqRackEventInfo 20 }
|
||
|
||
cpqRackEventAlertType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The event alert type."
|
||
::= { cpqRackEventInfo 21 }
|
||
|
||
cpqRackEventOtherAlertType OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE (0..33))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The event other alert type.
|
||
|
||
It is empty unless cpqRackEventAlertType value is other."
|
||
::= { cpqRackEventInfo 22 }
|
||
|
||
cpqRackEventProbableCause OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"An enumerated value that describes the probable cause of the error."
|
||
::= { cpqRackEventInfo 23 }
|
||
|
||
cpqRackEventProbableCauseDescription OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE (0..1024))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A free-form string describing the probable cause of the error."
|
||
::= { cpqRackEventInfo 24 }
|
||
|
||
cpqRackEventPerceivedSeverity OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"An enumerated value that describes the severity of the Indication from
|
||
the point of view of the notifier."
|
||
::= { cpqRackEventInfo 25 }
|
||
|
||
cpqRackEventOtherSeverity OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"Other perceived severity.
|
||
|
||
It is empty unless cpqRackEventPerceivedSeverity value is other."
|
||
::= { cpqRackEventInfo 26 }
|
||
|
||
cpqRackEventTrending OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The event trending."
|
||
::= { cpqRackEventInfo 27 }
|
||
|
||
cpqRackEventRecommendedActions OBJECT-TYPE
|
||
SYNTAX OCTET STRING ( SIZE (0..1024))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"A free-form string describing recommended actions to take to resolve the error."
|
||
::= { cpqRackEventInfo 28 }
|
||
|
||
cpqRackEventID OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"An instrumentation or provider specific value that describes the underlying real-world event
|
||
represented by the indication related to the not-OK status."
|
||
::= { cpqRackEventInfo 29 }
|
||
|
||
cpqRackEventTime OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE (0..33))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The event time."
|
||
::= { cpqRackEventInfo 30 }
|
||
|
||
cpqRackEventSystemCreationClassName OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The event system creation class name."
|
||
::= { cpqRackEventInfo 31 }
|
||
|
||
cpqRackEventSystemName OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The event system name."
|
||
::= { cpqRackEventInfo 32 }
|
||
|
||
cpqRackEventProviderName OBJECT-TYPE
|
||
SYNTAX DisplayString ( SIZE (0..64))
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"The name of the Provider that generated the indication related to the not-OK status."
|
||
::= { cpqRackEventInfo 33 }
|
||
|
||
|
||
|
||
-- ****************************************************************************
|
||
-- Rack Information Trap Definitions
|
||
-- =================================
|
||
--
|
||
-- The SNMP trap messages must not be bigger than 484 octets (bytes).
|
||
--
|
||
-- Trap support in an SNMP agent implementation is optional. An SNMP
|
||
-- agent implementation may support all, some, or none of the traps.
|
||
-- If traps are supported, The user should be provided with the option of
|
||
-- disabling traps.
|
||
-- **************************************************************************
|
||
|
||
cpqRackNameChanged TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackSerialNum,
|
||
cpqRackTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Rack name has changed.
|
||
|
||
This trap signifies that an agent or utility has changed the name
|
||
of the rack. Each of the server blades in each of the enclosure
|
||
within the rack will be updated to reflect the new rack name.
|
||
|
||
It may take several minutes for the rack name change to be
|
||
propagated throughout the entire rack.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Rack name changed (22001)"
|
||
--#SUMMARY "The rack name has changed to %s."
|
||
--#ARGUMENTS {2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY OA
|
||
--#LIFECYCLE
|
||
|
||
::= 22001
|
||
|
||
cpqRackEnclosureNameChanged TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureModel,
|
||
cpqRackCommonEnclosureSparePartNumber,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The enclosure name has changed.
|
||
|
||
This trap signifies that an agent or utility has changed the name
|
||
of an enclosure within the rack. Each of the components
|
||
within the rack will be updated to reflect the new enclosure name.
|
||
|
||
It may take several minutes for the enclosure name change to be
|
||
propagated throughout the entire enclosure.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Enclosure name changed (22002)"
|
||
--#SUMMARY "The enclosure name has changed to %s in rack %s."
|
||
--#ARGUMENTS {4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY OA
|
||
--#LIFECYCLE
|
||
|
||
::= 22002
|
||
|
||
cpqRackEnclosureRemoved TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureModel,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureSparePartNumber,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The enclosure has been removed.
|
||
|
||
This trap signifies that an enclosure has been removed from
|
||
the rack.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Enclosure removed (22003)"
|
||
--#SUMMARY "The enclosure %s has been removed from rack %s."
|
||
--#ARGUMENTS {4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY OA
|
||
--#LIFECYCLE
|
||
|
||
::= 22003
|
||
|
||
cpqRackEnclosureInserted TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureModel,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureSparePartNumber,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The enclosure has been inserted.
|
||
|
||
This trap signifies that an enclosure has been inserted into
|
||
the rack.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Enclosure inserted (22004)"
|
||
--#SUMMARY "The enclosure %s has been inserted into rack %s."
|
||
--#ARGUMENTS {4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY OA
|
||
--#LIFECYCLE
|
||
|
||
::= 22004
|
||
|
||
cpqRackEnclosureTempFailed TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTempLocation,
|
||
cpqRackCommonEnclosureSparePartNumber,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The enclosure temperature status has been set to failed.
|
||
|
||
This trap signifies that a enclosure temperature sensor has
|
||
been tripped indicating an overheat condition.
|
||
|
||
User Action: Shutdown the enclosure and possibly the rack
|
||
as soon as possible. Ensure all fans are working properly and
|
||
that air flow in the rack has not been blocked."
|
||
|
||
--#TYPE "Enclosure temperature failed (22005)"
|
||
--#SUMMARY "The temperature sensor %s in enclosure %s in rack %s has been set to failed."
|
||
--#ARGUMENTS {6, 4, 2}
|
||
--#SEVERITY CRITICAL
|
||
--#TIMEINDEX 99
|
||
--#STATE NONOPERATIONAL
|
||
--#SIMPLE_SEVERITY CRITICAL
|
||
--#HWSTATUS_CATEGORY THERMAL
|
||
--#ACTION "Shutdown the enclosure and possibly the rack as soon as possible. Ensure all fans are working properly and that air flow in the rack has not been blocked."
|
||
|
||
::= 22005
|
||
|
||
cpqRackEnclosureTempDegraded TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTempLocation,
|
||
cpqRackCommonEnclosureSparePartNumber,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The enclosure temperature status has been set to degraded.
|
||
|
||
This trap signifies that an enclosure temperature sensor has
|
||
been tripped indicating a possible overheat condition.
|
||
|
||
User Action: Shutdown the enclosure and possibly the rack
|
||
as soon as possible. Ensure all fans are working properly and
|
||
that air flow in the rack has not been blocked."
|
||
|
||
--#TYPE "Enclosure temperature degraded (22006)"
|
||
--#SUMMARY "The temperature sensor %s in enclosure %s in rack %s has been set to degraded."
|
||
--#ARGUMENTS {6, 4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY THERMAL
|
||
--#ACTION "Shutdown the enclosure and possibly the rack as soon as possible. Ensure all fans are working properly and that air flow in the rack has not been blocked."
|
||
|
||
::= 22006
|
||
|
||
cpqRackEnclosureTempOk TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTempLocation,
|
||
cpqRackCommonEnclosureSparePartNumber,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The enclosure temperature status has been set to ok.
|
||
|
||
This trap signifies that an enclosure temperature sensor has
|
||
returned to normal.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Enclosure temperature ok (22007)"
|
||
--#SUMMARY "The temperature sensor %s in enclosure %s in rack %s has been set to ok."
|
||
--#ARGUMENTS {6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY THERMAL
|
||
|
||
::= 22007
|
||
|
||
cpqRackEnclosureFanFailed TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureFanLocation,
|
||
cpqRackCommonEnclosureFanSparePartNumber,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The enclosure fan status has been set to failed.
|
||
|
||
This trap signifies that an enclosure fan has failed and
|
||
no other fans in the redundant fan group are operating.
|
||
This may result in overheating of the enclosure.
|
||
|
||
User Action: Replace the fan as soon as possible."
|
||
|
||
--#TYPE "Enclosure fan failed (22008)"
|
||
--#SUMMARY "The fan %s in enclosure %s in rack %s has been set to failed."
|
||
--#ARGUMENTS {6, 4, 2}
|
||
--#SEVERITY CRITICAL
|
||
--#TIMEINDEX 99
|
||
--#STATE NONOPERATIONAL
|
||
--#SIMPLE_SEVERITY CRITICAL
|
||
--#HWSTATUS_CATEGORY THERMAL
|
||
--#ACTION "Replace the failed enclosure fan."
|
||
|
||
::= 22008
|
||
|
||
cpqRackEnclosureFanDegraded TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureFanLocation,
|
||
cpqRackCommonEnclosureFanSparePartNumber,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The enclosure fan status has been set to degraded.
|
||
|
||
This trap signifies that an enclosure fan has failed but
|
||
other fans in the redundant fan group are still operating.
|
||
This may result in overheating of the enclosure.
|
||
|
||
User Action: Replace the fan as soon as possible."
|
||
|
||
--#TYPE "Enclosure fan degraded (22009)"
|
||
--#SUMMARY "The fan %s in enclosure %s in rack %s has been set to degraded."
|
||
--#ARGUMENTS {6, 4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY THERMAL
|
||
--#ACTION "Replace the failing enclosure fan."
|
||
|
||
::= 22009
|
||
|
||
cpqRackEnclosureFanOk TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureFanLocation,
|
||
cpqRackCommonEnclosureFanSparePartNumber,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The enclosure fan status has been set to ok.
|
||
|
||
This trap signifies that an enclosure fan has returned
|
||
to normal operation.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Enclosure fan ok (22010)"
|
||
--#SUMMARY "The fan %s in enclosure %s in rack %s has been set to ok."
|
||
--#ARGUMENTS {6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY THERMAL
|
||
|
||
::= 22010
|
||
|
||
|
||
cpqRackEnclosureFanRemoved TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureFanLocation,
|
||
cpqRackCommonEnclosureFanSparePartNumber,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The enclosure fan has been removed.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Enclosure fan removed (22011)"
|
||
--#SUMMARY "The fan %s in enclosure %s in rack %s has been removed."
|
||
--#ARGUMENTS {6, 4, 2}
|
||
--#SEVERITY MINOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY THERMAL
|
||
--#LIFECYCLE
|
||
|
||
::= 22011
|
||
|
||
cpqRackEnclosureFanInserted TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureFanLocation,
|
||
cpqRackCommonEnclosureFanSparePartNumber,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The enclosure fan has been inserted.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Enclosure fan inserted (22012)"
|
||
--#SUMMARY "The fan %s in enclosure %s in rack %s has been inserted."
|
||
--#ARGUMENTS {6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY THERMAL
|
||
--#LIFECYCLE
|
||
|
||
::= 22012
|
||
|
||
cpqRackPowerSupplyFailed TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackPowerSupplyEnclosureName,
|
||
cpqRackPowerSupplySerialNum,
|
||
cpqRackPowerSupplyPosition,
|
||
cpqRackPowerSupplyFWRev,
|
||
cpqRackPowerSupplySparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The power supply status has been set to failed.
|
||
|
||
This trap signifies that a power supply has failed.
|
||
|
||
User Action: Replace the power supply as soon as possible."
|
||
|
||
--#TYPE "Rack power supply failed (22013)"
|
||
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been set to failed."
|
||
--#ARGUMENTS {6, 4, 2}
|
||
--#SEVERITY CRITICAL
|
||
--#TIMEINDEX 99
|
||
--#STATE NONOPERATIONAL
|
||
--#SIMPLE_SEVERITY CRITICAL
|
||
--#HWSTATUS_CATEGORY POWER
|
||
--#ACTION "Replace the failed power supply."
|
||
|
||
::= 22013
|
||
|
||
cpqRackPowerSupplyDegraded TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackPowerSupplyEnclosureName,
|
||
cpqRackPowerSupplySerialNum,
|
||
cpqRackPowerSupplyPosition,
|
||
cpqRackPowerSupplyFWRev,
|
||
cpqRackPowerSupplySparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The power supply status has been set to degraded.
|
||
|
||
This trap signifies that a power supply has degraded.
|
||
|
||
User Action: Replace the power supply as soon as possible."
|
||
|
||
--#TYPE "Rack power supply degraded (22014)"
|
||
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been set to degraded."
|
||
--#ARGUMENTS {6, 4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY POWER
|
||
--#ACTION "Replace the failing power supply."
|
||
|
||
::= 22014
|
||
|
||
cpqRackPowerSupplyOk TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackPowerSupplyEnclosureName,
|
||
cpqRackPowerSupplySerialNum,
|
||
cpqRackPowerSupplyPosition,
|
||
cpqRackPowerSupplyFWRev,
|
||
cpqRackPowerSupplySparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The power supply status has been set to ok.
|
||
|
||
This trap signifies that a power supply has returned to normal
|
||
operation.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Rack power supply ok (22015)"
|
||
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been set to ok."
|
||
--#ARGUMENTS {6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY POWER
|
||
|
||
::= 22015
|
||
|
||
cpqRackPowerSupplyRemoved TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackPowerSupplyEnclosureName,
|
||
cpqRackPowerSupplySerialNum,
|
||
cpqRackPowerSupplyPosition,
|
||
cpqRackPowerSupplyFWRev,
|
||
cpqRackPowerSupplySparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The power supply has been removed.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Rack power supply removed (22016)"
|
||
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been removed."
|
||
--#ARGUMENTS {6, 4, 2}
|
||
--#SEVERITY MINOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY POWER
|
||
--#LIFECYCLE
|
||
|
||
::= 22016
|
||
|
||
cpqRackPowerSupplyInserted TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackPowerSupplyEnclosureName,
|
||
cpqRackPowerSupplySerialNum,
|
||
cpqRackPowerSupplyPosition,
|
||
cpqRackPowerSupplyFWRev,
|
||
cpqRackPowerSupplySparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The power supply has been inserted.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Rack power supply inserted (22017)"
|
||
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been inserted."
|
||
--#ARGUMENTS {6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY POWER
|
||
--#LIFECYCLE
|
||
|
||
::= 22017
|
||
|
||
cpqRackPowerSubsystemNotRedundant TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackPowerEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The rack power subsystem is no longer in a redundant state.
|
||
|
||
User Action: Replace any failed power supplies as soon as possible
|
||
to return the system to a redundant state."
|
||
|
||
--#TYPE "Rack power subsystem not redundant (22018)"
|
||
--#SUMMARY "The power subsystem in enclosure %s in rack %s is no longer redundant."
|
||
--#ARGUMENTS {4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY POWER
|
||
--#ACTION "Replace any failed power supplies as soon as possible to return the system to a redundant state."
|
||
--#CLEAR_PRIOR_EVENTS true
|
||
|
||
::= 22018
|
||
|
||
cpqRackPowerSubsystemLineVoltageProblem TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackPowerSupplyEnclosureName,
|
||
cpqRackPowerSupplyPosition,
|
||
cpqRackPowerSupplyFWRev,
|
||
cpqRackPowerSupplyInputLineStatus,
|
||
cpqRackPowerSupplySparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The rack power supply detected an input line voltage problem.
|
||
|
||
User Action: Check the power input for the power supply or replace
|
||
any failed power supplies as soon as possible."
|
||
|
||
--#TYPE "Rack power supply input voltage problem (22019)"
|
||
--#SUMMARY "The rack power supply detected an input line voltage problem in power supply %s, enclosure %s, rack %s."
|
||
--#ARGUMENTS {5, 4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY POWER
|
||
--#ACTION "Check the power input for the power supply or replace any failed power supplies as soon as possible."
|
||
|
||
::= 22019
|
||
|
||
cpqRackPowerSubsystemOverloadCondition TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackPowerEnclosureName,
|
||
cpqRackCommonEnclosureSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The rack power subsystem overload condition.
|
||
|
||
User Action: Replace any failed power supplies as soon as possible
|
||
to return the system to a redundant state."
|
||
|
||
--#TYPE "Rack power subsystem overload condition (22020)"
|
||
--#SUMMARY "The power subsystem in enclosure %s in rack %s is in an overload condition."
|
||
--#ARGUMENTS {4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY POWER
|
||
--#ACTION "Replace any failed power supplies as soon as possible."
|
||
--#CLEAR_PRIOR_EVENTS true
|
||
::= 22020
|
||
|
||
cpqRackPowerShedAutoShutdown TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server shutdown due to power shedding.
|
||
|
||
The server blade was shutdown due to a lack of power.
|
||
|
||
User Action: Check power connections or add power supplies."
|
||
|
||
--#TYPE "Server shutdown due to power shedding (22021)"
|
||
--#SUMMARY "The server shutdown due to lack of power blade %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 4, 2}
|
||
--#SEVERITY CRITICAL
|
||
--#TIMEINDEX 99
|
||
--#STATE NONOPERATIONAL
|
||
--#SIMPLE_SEVERITY CRITICAL
|
||
--#HWSTATUS_CATEGORY POWER
|
||
--#ACTION "Check the power connections for problems, then add power supplies if necessary."
|
||
|
||
::= 22021
|
||
|
||
cpqRackServerPowerOnFailedNotRedundant TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server power on prevented to preserve redundancy.
|
||
|
||
There is not enough power to power on the server blade and
|
||
maintain redundancy for the other blades in the enclosure.
|
||
|
||
User Action: Check power connections or add power supplies."
|
||
|
||
--#TYPE "Server power on prevented to preserve redundancy (22022)"
|
||
--#SUMMARY "Server power on prevented to preserve redundancy in blade %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 4, 2}
|
||
--#SEVERITY CRITICAL
|
||
--#TIMEINDEX 99
|
||
--#STATE NONOPERATIONAL
|
||
--#SIMPLE_SEVERITY CRITICAL
|
||
--#HWSTATUS_CATEGORY POWER
|
||
--#ACTION "Check the power connections for problems, then add power supplies if necessary."
|
||
|
||
::= 22022
|
||
|
||
cpqRackServerPowerOnFailedNotEnoughPower TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Inadequate power to power on.
|
||
|
||
There is not enough power to power on the server blade.
|
||
|
||
User Action: Check power connections or add power supplies."
|
||
|
||
--#TYPE "Inadequate power to power on (22023)"
|
||
--#SUMMARY "Inadequate power to power on blade %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 4, 2}
|
||
--#SEVERITY CRITICAL
|
||
--#TIMEINDEX 99
|
||
--#STATE NONOPERATIONAL
|
||
--#SIMPLE_SEVERITY CRITICAL
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#ACTION "Check the power connections for problems, then add power supplies if necessary."
|
||
|
||
::= 22023
|
||
|
||
cpqRackServerPowerOnFailedEnclosureNotFound TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Inadequate power to power on.
|
||
|
||
There is not enough power to power on the server blade. The
|
||
server enclosure micro-controller was not found.
|
||
|
||
User Action: Check server enclosure connections or add power supplies."
|
||
|
||
--#TYPE "Inadequate power to power on (22024)"
|
||
--#SUMMARY "Inadequate power to power on blade %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 4, 2}
|
||
--#SEVERITY CRITICAL
|
||
--#TIMEINDEX 99
|
||
--#STATE NONOPERATIONAL
|
||
--#SIMPLE_SEVERITY CRITICAL
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#ACTION "Check the server enclosure connections for problems, then add power supplies if necessary."
|
||
|
||
::= 22024
|
||
|
||
cpqRackServerPowerOnFailedPowerChassisNotFound TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Inadequate power to power on.
|
||
|
||
There is not enough power to power on the server blade. The
|
||
power enclosure micro-controller was not found.
|
||
|
||
User Action: Check power enclosure connections or add power supplies."
|
||
|
||
--#TYPE "Inadequate power to power on (22025)"
|
||
--#SUMMARY "Inadequate power to power on blade %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 4, 2}
|
||
--#SEVERITY CRITICAL
|
||
--#TIMEINDEX 99
|
||
--#STATE NONOPERATIONAL
|
||
--#SIMPLE_SEVERITY CRITICAL
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#ACTION "Check the power enclosure connections for problems, then add power supplies if necessary."
|
||
|
||
::= 22025
|
||
|
||
cpqRackServerPowerOnManualOverride TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server power on via manual override.
|
||
|
||
The server blade was powered on by a manual override.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server power on via manual override (22026)"
|
||
--#SUMMARY "Server power on via manual override on blade %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
|
||
::= 22026
|
||
|
||
cpqRackFuseOpen TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureFuseLocation,
|
||
cpqRackCommonEnclosureSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Fuse open.
|
||
|
||
The fuse has been tripped.
|
||
|
||
User Action: Check enclosure and / or blade power connections and
|
||
reset the fuse."
|
||
|
||
--#TYPE "Fuse open (22027)"
|
||
--#SUMMARY "Fuse open fuse %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY ENCLOSURE
|
||
--#ACTION "Check the enclosure and blade power connections, then reset the fuse."
|
||
|
||
::= 22027
|
||
|
||
|
||
cpqRackServerBladeRemoved TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade removed.
|
||
|
||
The server blade has been removed from the enclosure.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade removed (22028)"
|
||
--#SUMMARY "Server blade %s removed from position %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22028
|
||
|
||
cpqRackServerBladeInserted TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade inserted.
|
||
|
||
The server blade has been inserted into the enclosure.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade inserted (22029)"
|
||
--#SUMMARY "Server blade %s inserted into position %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22029
|
||
|
||
cpqRackPowerChassisNotLoadBalanced TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureSparePartNumber,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Power subsystem not load balanced.
|
||
|
||
The power subsystem is out of balance for this power enclosure.
|
||
|
||
User Action: Check the power enclosure and power supplies. Replace
|
||
any failed or degraded power supplies. Add additional power supplies
|
||
if needed."
|
||
|
||
--#TYPE "Power subsystem not load balanced (22030)"
|
||
--#SUMMARY "Power subsystem not load balanced in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY POWER
|
||
--#ACTION "Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Add additional power supplies if needed."
|
||
|
||
::= 22030
|
||
|
||
cpqRackPowerChassisDcPowerProblem TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureSparePartNumber,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Power subsystem DC power problem.
|
||
|
||
There is a power subsystem DC power problem for this power enclosure.
|
||
|
||
User Action: Check the power enclosure and power supplies. Replace
|
||
any failed or degraded power supplies."
|
||
|
||
--#TYPE "Power subsystem DC power problem (22031)"
|
||
--#SUMMARY "Power subsystem DC power problem in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY POWER
|
||
--#ACTION "Check the power enclosure and power supplies. Replace any failed or degraded power supplies."
|
||
|
||
::= 22031
|
||
|
||
cpqRackPowerChassisAcFacilityPowerExceeded TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureSparePartNumber,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Power subsystem AC facility input power exceeded.
|
||
|
||
There is a power subsystem Power subsystem AC facility input power
|
||
exceeded for this power enclosure.
|
||
|
||
User Action: Check the power enclosure and power supplies. Replace
|
||
any failed or degraded power supplies."
|
||
|
||
--#TYPE "Power subsystem AC facility input power exceeded (22032)"
|
||
--#SUMMARY "Power subsystem AC facility input power exceeded in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY POWER
|
||
--#ACTION "Check the power enclosure and power supplies. Replace any failed or degraded power supplies."
|
||
|
||
::= 22032
|
||
|
||
|
||
|
||
cpqRackPowerUnknownPowerConsumption TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Unknown power consumption.
|
||
|
||
There is an unknown power consumer drawing power.
|
||
|
||
User Action: Check the power enclosure and power supplies. Replace
|
||
any failed or degraded power supplies."
|
||
|
||
--#TYPE "Unknown power consumption (22033)"
|
||
--#SUMMARY "Unknown power consumption in rack %s."
|
||
--#ARGUMENTS {2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY POWER
|
||
--#ACTION "Check the power enclosure and power supplies. Replace any failed or degraded power supplies."
|
||
|
||
::= 22033
|
||
|
||
cpqRackPowerChassisLoadBalancingWireMissing TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureSparePartNumber,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Power subsystem load balancing wire missing.
|
||
|
||
The power subsystem load balancing wire missing.
|
||
|
||
User Action: Connect the load balancing wire."
|
||
|
||
--#TYPE "Power subsystem load balancing wire missing (22034)"
|
||
--#SUMMARY "Power subsystem load balancing wire missing for enclosure %s, in rack %s."
|
||
--#ARGUMENTS {4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY POWER
|
||
--#ACTION "Connect the load balancing wire."
|
||
|
||
::= 22034
|
||
|
||
cpqRackPowerChassisTooManyPowerChassis TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Power subsystem has too may power enclosures.
|
||
|
||
The maximum number of power enclosures has been exceeded.
|
||
|
||
User Action: Remove the extra power enclosure."
|
||
|
||
--#TYPE "Power subsystem has too may power enclosures (22035)"
|
||
--#SUMMARY "Power subsystem has too may power enclosures %s, in rack %s."
|
||
--#ARGUMENTS {4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY POWER
|
||
--#ACTION "Remove the extra power enclosure."
|
||
|
||
::= 22035
|
||
|
||
cpqRackPowerChassisConfigError TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureSparePartNumber,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Power subsystem improperly configured.
|
||
|
||
The power subsystem has been improperly configured.
|
||
|
||
User Action: Check the cabling of the power enclosure."
|
||
|
||
--#TYPE "Power subsystem improperly configured (22036)"
|
||
--#SUMMARY "Power subsystem has been improperly configured in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY POWER
|
||
--#ACTION "Check the cabling of the power enclosure."
|
||
|
||
::= 22036
|
||
|
||
cpqRackEnclosureManagerDegraded TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureManagerLocation,
|
||
cpqRackCommonEnclosureManagerSparePartNumber,
|
||
cpqRackCommonEnclosureManagerSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The Onboard Administrator or other management processor status has been set to degraded.
|
||
|
||
This trap signifies that either the Onboard Administrator(s) or its component(s) has degraded/failed,
|
||
their firmware versions are mismatched, or one or more management processors is in a non-optimal operating state.
|
||
|
||
User Action: For C-Class enclosures, please refer to the Onboard Administrator SYSLOG.
|
||
For all the others please refer to product documentation for possible corrective actions"
|
||
|
||
--#TYPE "Enclosure manager degraded (22037)"
|
||
--#SUMMARY "The enclosure %s manager in rack %s has been set to degraded."
|
||
--#ARGUMENTS {4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY OA
|
||
--#ACTION "The following conditions can result in a degraded Onboard Administrator (OA): 1) one OA failed but the second OA is still operating, 2) one or more OAs is in a non-optimal operating state, 3) a firmware revision mismatch occurred between the primary and secondary OAs, or 4) OA RTC battery is low.<2E> To determine what caused the issue, see the OA and check the logs for more information.<2E> If a firmware mismatch occurred, use the OA UI or CLI (UPDATE IMAGE SYNC command) to resynchronize the firmware on the OAs.<2E> If OA RTC battery is found to be low, replace battery."
|
||
|
||
|
||
::= 22037
|
||
|
||
cpqRackEnclosureManagerOk TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureManagerLocation,
|
||
cpqRackCommonEnclosureManagerSparePartNumber,
|
||
cpqRackCommonEnclosureManagerSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The Onboard Administrator or other management processor's status has been set to ok.
|
||
|
||
This trap signifies that an Onboard Administrator or other management processor has returned
|
||
to normal operation.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Onboard or management processor ok (22038)"
|
||
--#SUMMARY "The Onboard Administrator or management processor %s in rack %s has been set to ok."
|
||
--#ARGUMENTS {4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY OA
|
||
|
||
::= 22038
|
||
|
||
cpqRackEnclosureManagerRemoved TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureManagerLocation,
|
||
cpqRackCommonEnclosureManagerSparePartNumber,
|
||
cpqRackCommonEnclosureManagerSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The Onboard Administrator has been removed.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Onboard Administrator removed (22039)"
|
||
--#SUMMARY "The Onboard Administrator %s in rack %s has been removed."
|
||
--#ARGUMENTS {4, 2}
|
||
--#SEVERITY MINOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY OA
|
||
--#LIFECYCLE
|
||
|
||
::= 22039
|
||
|
||
cpqRackEnclosureManagerInserted TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureManagerLocation,
|
||
cpqRackCommonEnclosureManagerSparePartNumber,
|
||
cpqRackCommonEnclosureManagerSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The Onboard Administrator or other management processor has been inserted.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Onboard Administrator or other management processor inserted (22040)"
|
||
--#SUMMARY "The Onboard Administrator or other management processor %s in rack %s has been inserted."
|
||
--#ARGUMENTS {4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY OA
|
||
--#LIFECYCLE
|
||
|
||
::= 22040
|
||
|
||
cpqRackManagerPrimaryRole TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureManagerLocation,
|
||
cpqRackCommonEnclosureManagerSparePartNumber,
|
||
cpqRackCommonEnclosureManagerSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The Onboard Administrator or other management processor has taken the role of primary.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Onboard Administrator or other management processor has taken the role of primary (UID)."
|
||
--#SUMMARY "Onboard Administrator or other management processor has taken the role of primary, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY OA
|
||
|
||
::= 22041
|
||
|
||
cpqRackServerBladeEKeyingFailed TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The server blade e-keying has failed.
|
||
|
||
This trap signifies that a server blade e-keying has failed and
|
||
there is a port mapping problem between a server mezz card
|
||
and the interconnect.
|
||
|
||
User Action: Reconfigure server blade mezz cards."
|
||
|
||
--#TYPE "Server Blade e-keying failed (22042)"
|
||
--#SUMMARY "Server blade %s e-keying failed in position %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#ACTION "Reconfigure the server blade mezz cards."
|
||
|
||
::= 22042
|
||
|
||
cpqRackServerBladeEKeyingOK TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The server blade e-keying is ok.
|
||
|
||
This trap signifies that a server blade e-keying has returned to
|
||
normal operation.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server Blade e-keying ok (22043)"
|
||
--#SUMMARY "Server blade %s e-keying is ok in position %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
|
||
::= 22043
|
||
|
||
cpqRackNetConnectorRemoved TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackNetConnectorEnclosureName,
|
||
cpqRackNetConnectorName,
|
||
cpqRackNetConnectorLocation,
|
||
cpqRackNetConnectorSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Interconnect removed.
|
||
|
||
The interconnect has been removed from the enclosure.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Interconnect removed (22044)"
|
||
--#SUMMARY "Interconnect %s removed from position %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY INTERCONNECTBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22044
|
||
|
||
cpqRackNetConnectorInserted TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackNetConnectorEnclosureName,
|
||
cpqRackNetConnectorName,
|
||
cpqRackNetConnectorLocation,
|
||
cpqRackNetConnectorSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Interconnect inserted.
|
||
|
||
The interconnect has been inserted into the enclosure.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Interconnect inserted (22045)"
|
||
--#SUMMARY "Interconnect %s inserted into position %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY INTERCONNECTBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22045
|
||
|
||
cpqRackNetConnectorFailed TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackNetConnectorEnclosureName,
|
||
cpqRackNetConnectorName,
|
||
cpqRackNetConnectorLocation,
|
||
cpqRackNetConnectorSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The interconnect status has been set to failed.
|
||
|
||
This trap signifies that a interconnect has failed.
|
||
|
||
User Action: Replace the interconnect as soon as possible."
|
||
|
||
--#TYPE "Interconnect failed (22046)"
|
||
--#SUMMARY "Interconnect %s failed in position %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY CRITICAL
|
||
--#TIMEINDEX 99
|
||
--#STATE NONOPERATIONAL
|
||
--#SIMPLE_SEVERITY CRITICAL
|
||
--#HWSTATUS_CATEGORY INTERCONNECTBAY
|
||
--#ACTION "Refer to the OA and the status diagnostics reported for the interconnect."
|
||
|
||
::= 22046
|
||
|
||
cpqRackNetConnectorDegraded TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackNetConnectorEnclosureName,
|
||
cpqRackNetConnectorName,
|
||
cpqRackNetConnectorLocation,
|
||
cpqRackNetConnectorSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The interconnect status has been set to degraded.
|
||
|
||
This trap signifies that a interconnect has degraded.
|
||
|
||
User Action: Refer to the OA and the status diagnostics reported for the interconnect."
|
||
|
||
--#TYPE "Interconnect degraded (22047)"
|
||
--#SUMMARY "Interconnect %s degraded in position %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY INTERCONNECTBAY
|
||
--#ACTION "Refer to the OA and the status diagnostics reported for the interconnect."
|
||
|
||
::= 22047
|
||
|
||
cpqRackNetConnectorOk TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackNetConnectorEnclosureName,
|
||
cpqRackNetConnectorName,
|
||
cpqRackNetConnectorLocation,
|
||
cpqRackNetConnectorSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The interconnect status has been set to ok.
|
||
|
||
This trap signifies that a interconnect has returned to
|
||
normal operation.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Interconnect ok (22048)"
|
||
--#SUMMARY "Interconnect %s ok in position %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY INTERCONNECTBAY
|
||
|
||
::= 22048
|
||
|
||
cpqRackServerBladeToLowPower TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The server blade requested to low power.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server Blade requested to low power (22049)"
|
||
--#SUMMARY "Server blade %s requested to low power in position %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
|
||
::= 22049
|
||
|
||
cpqRackServerBladeRemoved2 TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade removed.
|
||
|
||
The server blade has been removed from the enclosure.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade removed (22050)"
|
||
--#SUMMARY "Server blade %s removed from position %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22050
|
||
|
||
cpqRackServerBladeInserted2 TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade inserted.
|
||
|
||
The server blade has been inserted into the enclosure.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade inserted (22051)"
|
||
--#SUMMARY "Server blade %s inserted into position %s, in enclosure %s, in rack %s."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22051
|
||
|
||
cpqRackServerBladeStatusRepaired TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladeProductId,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade repaired.
|
||
|
||
The server blade status has changed to OK.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade repaired (22052)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s status has changed to OK."
|
||
--#ARGUMENTS {5, 7, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
|
||
::= 22052
|
||
|
||
cpqRackServerBladeStatusDegraded TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladeProductId,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackServerBladeFaultMajor,
|
||
cpqRackServerBladeFaultMinor,
|
||
cpqRackServerBladeFaultDiagnosticString,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade health status Degraded.
|
||
|
||
The server blade health status has changed to Degraded.
|
||
|
||
User Action: Check blade server and enclosure SYSLOG."
|
||
|
||
--#TYPE "Server blade health status degraded (22053)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s health status has changed to degraded. Reason: %s."
|
||
--#ARGUMENTS {5, 7, 4, 2, 14}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#ACTION "Check the blade server and enclosure SYSLOG."
|
||
|
||
::= 22053
|
||
|
||
cpqRackServerBladeStatusCritical TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladeProductId,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackServerBladeFaultMajor,
|
||
cpqRackServerBladeFaultMinor,
|
||
cpqRackServerBladeFaultDiagnosticString,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade health status Critical.
|
||
|
||
The server blade health status has changed to Critical.
|
||
|
||
User Action: Check blade server and enclosure SYSLOG."
|
||
|
||
--#TYPE "Server blade health status critical (22054)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s health status has changed to critical. Reason: %s."
|
||
--#ARGUMENTS {5, 7, 4, 2, 14}
|
||
--#SEVERITY CRITICAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY CRITICAL
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#ACTION "Check the blade server and enclosure SYSLOG."
|
||
|
||
::= 22054
|
||
|
||
cpqRackServerBladeGrpCapTimeout TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The server blade is not responding to the group capper.
|
||
|
||
The server blade is not responding to capping requests from the enclosure group capper
|
||
|
||
User Action: Reset the iLO management processor."
|
||
|
||
--#TYPE "Server blade not responding to group capping requests (22055)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s is not responding to requests from the enclosure group capper."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY CRITICAL
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY CRITICAL
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#ACTION "Reset the iLO management processor."
|
||
|
||
::= 22055
|
||
|
||
cpqRackServerBladeUnexpectedShutdown TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade shutdown unexpectadly.
|
||
|
||
An unexpected shutdown event has occurred for this server blade.
|
||
|
||
User Action: Check blade server and enclosure SYSLOG."
|
||
|
||
--#TYPE "Server blade unexpected shutdown (22056)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has unexpectedly shutdown."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#ACTION "Check the blade server and enclosure SYSLOG."
|
||
|
||
::= 22056
|
||
|
||
cpqRackServerBladeMangementControllerFirmwareUpdating TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackServerBladeManagementDeviceFirmwareFlashingStatus,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade's management controller firmware updating.
|
||
|
||
This server blade's management controller has started updating it's firmware.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade management controller firmware update started (22057)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has started updating it's management controller firmware."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22057
|
||
|
||
cpqRackServerBladeMangementControllerFirmwareUpdateComplete TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackServerBladeManagementDeviceFirmwareFlashingStatus,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade's management controller firmware update has completed.
|
||
|
||
This server blade's management controller has finished updating it's firmware.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade management controller firmware update completed (22058)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has finished updating it's management controller firmware."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22058
|
||
|
||
cpqRackServerBladeSystemBIOSFirmwareUpdating TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackServerBladeSystemBIOSFlashingStatus,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade's system BIOS firmware updating.
|
||
|
||
This server blade's system BIOS has started updating.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade system BIOS firmware update started (22059)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has started updating it's system BIOS firmware."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22059
|
||
|
||
cpqRackServerBladeSystemBIOSFirmwareUpdateCompleted TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackServerBladeSystemBIOSFlashingStatus,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade's system BIOS firmware update complete.
|
||
|
||
This server blade's system BIOS has completed updating.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade system BIOS firmware update completed (22060)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has completed updating it's system BIOS firmware."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22060
|
||
|
||
|
||
cpqRackServerBladeFrontIOBlankingActive TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackServerBladeFrontIOBlankingModeStatus,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade has disabled front IO ports.
|
||
|
||
Front IO blanking status has changed to active for this server blade.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade front IO blanking active (22061)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has disabled front IO."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22061
|
||
|
||
|
||
cpqRackServerBladeRemoteFrontIOBlankingInactive TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackServerBladeFrontIOBlankingModeStatus,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade has front IO blanking mode now inactive.
|
||
|
||
Front IO blanking status has changed to inactive for this server blade.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade front IO blanking inactive (22062)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has enabled front IO."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22062
|
||
|
||
cpqRackServerBladeDiagnosticAdaptorInserted TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackServerBladeDiagnosticAdaptorPresence,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade diagnostic adaptor inserted.
|
||
|
||
Blade diagnostic adaptor status has changed to inserted for this server blade.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade diagnostic adaptor inserted (22063)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s diagnostic adaptor inserted."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22063
|
||
|
||
cpqRackServerBladeDiagnosticAdaptorRemoved TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackServerBladeDiagnosticAdaptorPresence,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade diagnostic adaptor removed.
|
||
|
||
Blade diagnostic adaptor status has changed to removed for this server blade.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade diagnostic adaptor removed (22064)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s diagnostic adaptor removed."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22064
|
||
|
||
cpqRackServerBladeEnteredPXEBootMode TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackServerBladePXEBootModeStatus,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade has entered PXE Boot Mode.
|
||
|
||
Server blade Pre-Boot-eXecution (PXE) Mode started.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade has entered PXE Boot Mode (22065)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has entered PXE Boot Mode."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22065
|
||
|
||
cpqRackServerBladeExitedPXEBootMode TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackServerBladePXEBootModeStatus,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade has exited PXE Boot Mode.
|
||
|
||
Server blade Pre-Boot-eXecution (PXE) Mode exited.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade has exited PXE Boot Mode (22066)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has exited PXE Boot Mode."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22066
|
||
|
||
|
||
cpqRackServerBladeWarmReset TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackServerBladePOSTStatus,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade has been warm reset.
|
||
|
||
Server blade has experienced a warm reset.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade warm reset occurred (22067)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has been warm reset."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22067
|
||
|
||
cpqRackServerBladePOSTCompleted TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackServerBladePOSTStatus,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade system BIOS POST complete.
|
||
|
||
Server blade has completed system BIOS Power-On-Self-Test (POST).
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade system BIOS POST completed (22068)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s system BIOS POST completed."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22068
|
||
|
||
cpqRackServerBladePoweredOn TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackServerBladePowered,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade has powered on.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade has powered on (22069)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has powered on."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22069
|
||
|
||
cpqRackServerBladePoweredOff TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackServerBladePowered,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server blade has powered off.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade has powered off (22070)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s has powered off."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22070
|
||
|
||
cpqRackInformationalEAETrap TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackCommonEnclosureTrapSequenceNum,
|
||
cpqRackLastEAEEvent }
|
||
|
||
DESCRIPTION
|
||
"EAE Informational trap"
|
||
|
||
--#TYPE "Generic EAE Informational trap"
|
||
--#SUMMARY "%s"
|
||
--#ARGUMENTS {6}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY NONE
|
||
|
||
::= 22071
|
||
|
||
cpqRackMinorEAETrap TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackCommonEnclosureTrapSequenceNum,
|
||
cpqRackLastEAEEvent }
|
||
|
||
DESCRIPTION
|
||
"EAE Minor trap"
|
||
|
||
--#TYPE "Generic EAE Minor trap"
|
||
--#SUMMARY "%s"
|
||
--#ARGUMENTS {6}
|
||
--#SEVERITY MINOR
|
||
--#TIMEINDEX 99
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY NONE
|
||
::= 22072
|
||
|
||
cpqRackMajorEAETrap TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackCommonEnclosureTrapSequenceNum,
|
||
cpqRackLastEAEEvent }
|
||
|
||
DESCRIPTION
|
||
"EAE Major trap"
|
||
|
||
--#TYPE "Generic EAE Major trap"
|
||
--#SUMMARY "%s"
|
||
--#ARGUMENTS {6}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY NONE
|
||
::= 22073
|
||
|
||
cpqRackCriticalEAETrap TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackCommonEnclosureTrapSequenceNum,
|
||
cpqRackLastEAEEvent }
|
||
|
||
DESCRIPTION
|
||
"EAE Critical trap"
|
||
|
||
--#TYPE "Generic EAE Critical trap"
|
||
--#SUMMARY "%s"
|
||
--#ARGUMENTS {6}
|
||
--#SEVERITY CRITICAL
|
||
--#TIMEINDEX 99
|
||
--#SIMPLE_SEVERITY CRITICAL
|
||
--#HWSTATUS_CATEGORY NONE
|
||
::= 22074
|
||
|
||
cpqRackPowerMinorEAETrap TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackCommonEnclosureTrapSequenceNum,
|
||
cpqRackLastEAEEvent }
|
||
|
||
DESCRIPTION
|
||
"FlexFabric Cmdr Power Subsystem Minor trap.
|
||
User Action: For FlexFabric Cmdr, please refer to product documentation for
|
||
possible corrective actions."
|
||
|
||
--#TYPE "Generic Power Subsystem EAE Minor trap"
|
||
--#SUMMARY "%s"
|
||
--#ARGUMENTS {6}
|
||
--#SEVERITY MINOR
|
||
--#TIMEINDEX 99
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY NONE
|
||
::= 22075
|
||
|
||
|
||
cpqRackPowerMajorEAETrap TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackCommonEnclosureTrapSequenceNum,
|
||
cpqRackLastEAEEvent }
|
||
|
||
DESCRIPTION
|
||
"FlexFabric Cmdr Power Subsystem Major trap.
|
||
User Action: For FlexFabric Cmdr, please refer to product documentation for
|
||
possible corrective actions."
|
||
|
||
--#TYPE "Generic Power Subsystem EAE Major trap"
|
||
--#SUMMARY "%s"
|
||
--#ARGUMENTS {6}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY NONE
|
||
::= 22076
|
||
|
||
cpqRackPowerCriticalEAETrap TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackCommonEnclosureTrapSequenceNum,
|
||
cpqRackLastEAEEvent }
|
||
|
||
DESCRIPTION
|
||
"FlexFabric Cmdr Power Subsystem Critical trap.
|
||
User Action: For FlexFabric Cmdr, please refer to product documentation for
|
||
possible corrective actions."
|
||
|
||
--#TYPE "Generic Power Subsystem EAE Critical trap"
|
||
--#SUMMARY "%s"
|
||
--#ARGUMENTS {6}
|
||
--#SEVERITY CRITICAL
|
||
--#TIMEINDEX 99
|
||
--#SIMPLE_SEVERITY CRITICAL
|
||
--#HWSTATUS_CATEGORY NONE
|
||
::= 22077
|
||
|
||
cpqRackServerBladePartitionChange TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackServerBladeEnclosureName,
|
||
cpqRackServerBladeName,
|
||
cpqRackServerBladePosition,
|
||
cpqRackServerBladeSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackServerBladeSerialNum,
|
||
cpqRackServerBladeUid,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"Server Blade Partition Changed trap.
|
||
|
||
The server blade is part of a conjoined blade and its partition has changed.
|
||
|
||
User Action: None."
|
||
|
||
--#TYPE "Server blade partition changed (22078)"
|
||
--#SUMMARY "Server blade %s in position %s, in enclosure %s, in rack %s partition has changed."
|
||
--#ARGUMENTS {5, 6, 4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY DEVICEBAY
|
||
--#LIFECYCLE
|
||
|
||
::= 22078
|
||
|
||
cpqRackInformationalWSMANTrap TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureTrapSequenceNum,
|
||
cpqRackLastEAEEvent,
|
||
cpqRackEventIndicationIdentifier,
|
||
cpqRackEventIndicationTime,
|
||
cpqRackEventDescription,
|
||
cpqRackEventSummary,
|
||
cpqRackEventCategory,
|
||
cpqRackOtherEventCategory,
|
||
cpqRackEventSubCategory,
|
||
cpqRackOtherEventSubCategory,
|
||
cpqRackEventThreshold,
|
||
cpqRackEventTimeWin,
|
||
cpqRackEventActualThreshold,
|
||
cpqRackEventActualTimeWin,
|
||
cpqRackEventProviderVersion,
|
||
cpqHoOsType,
|
||
cpqHoVersion,
|
||
cpqRackNetworkAddresses,
|
||
cpqRackSerialNum,
|
||
cpqRackEventAlertingElementFormat,
|
||
cpqRackEventOtherAlertingElementFormat,
|
||
cpqRackEventImpactedDomain,
|
||
cpqRackEventComplexName,
|
||
cpqRackEventPartitionId,
|
||
cpqRackEventTriggeringLogID,
|
||
cpqRackEventTriggeringLogIDFormat,
|
||
cpqRackHWPartNumber,
|
||
cpqRackHWFirmwareVersion,
|
||
cpqRackHWManufacturer,
|
||
cpqRackHWSerialNumber,
|
||
cpqRackHWFRUDetails,
|
||
cpqRackHWDevicePermanentNameFormat,
|
||
cpqRackHWOtherPermanentNameFormat,
|
||
cpqRackEventAlertType,
|
||
cpqRackEventOtherAlertType,
|
||
cpqRackEventProbableCause,
|
||
cpqRackEventProbableCauseDescription,
|
||
cpqRackEventPerceivedSeverity,
|
||
cpqRackEventOtherSeverity,
|
||
cpqRackEventTrending,
|
||
cpqRackEventRecommendedActions,
|
||
cpqRackEventID,
|
||
cpqRackEventTime,
|
||
cpqRackEventSystemCreationClassName,
|
||
cpqRackEventSystemName,
|
||
cpqRackEventProviderName }
|
||
|
||
DESCRIPTION
|
||
"WSMAN Informational trap"
|
||
|
||
--#TYPE "Generic WSMAN Informational trap"
|
||
--#SUMMARY "%s"
|
||
--#ARGUMENTS {6}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY NONE
|
||
|
||
::= 22079
|
||
|
||
cpqRackMinorWSMANTrap TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureTrapSequenceNum,
|
||
cpqRackLastEAEEvent,
|
||
cpqRackEventIndicationIdentifier,
|
||
cpqRackEventIndicationTime,
|
||
cpqRackEventDescription,
|
||
cpqRackEventSummary,
|
||
cpqRackEventCategory,
|
||
cpqRackOtherEventCategory,
|
||
cpqRackEventSubCategory,
|
||
cpqRackOtherEventSubCategory,
|
||
cpqRackEventThreshold,
|
||
cpqRackEventTimeWin,
|
||
cpqRackEventActualThreshold,
|
||
cpqRackEventActualTimeWin,
|
||
cpqRackEventProviderVersion,
|
||
cpqHoOsType,
|
||
cpqHoVersion,
|
||
cpqRackNetworkAddresses,
|
||
cpqRackSerialNum,
|
||
cpqRackEventAlertingElementFormat,
|
||
cpqRackEventOtherAlertingElementFormat,
|
||
cpqRackEventImpactedDomain,
|
||
cpqRackEventComplexName,
|
||
cpqRackEventPartitionId,
|
||
cpqRackEventTriggeringLogID,
|
||
cpqRackEventTriggeringLogIDFormat,
|
||
cpqRackHWPartNumber,
|
||
cpqRackHWFirmwareVersion,
|
||
cpqRackHWManufacturer,
|
||
cpqRackHWSerialNumber,
|
||
cpqRackHWFRUDetails,
|
||
cpqRackHWDevicePermanentNameFormat,
|
||
cpqRackHWOtherPermanentNameFormat,
|
||
cpqRackEventAlertType,
|
||
cpqRackEventOtherAlertType,
|
||
cpqRackEventProbableCause,
|
||
cpqRackEventProbableCauseDescription,
|
||
cpqRackEventPerceivedSeverity,
|
||
cpqRackEventOtherSeverity,
|
||
cpqRackEventTrending,
|
||
cpqRackEventRecommendedActions,
|
||
cpqRackEventID,
|
||
cpqRackEventTime,
|
||
cpqRackEventSystemCreationClassName,
|
||
cpqRackEventSystemName,
|
||
cpqRackEventProviderName }
|
||
|
||
DESCRIPTION
|
||
"WSMAN Minor trap"
|
||
|
||
--#TYPE "Generic WSMAN Minor trap"
|
||
--#SUMMARY "%s"
|
||
--#ARGUMENTS {6}
|
||
--#SEVERITY MINOR
|
||
--#TIMEINDEX 99
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY NONE
|
||
::= 22080
|
||
|
||
cpqRackMajorWSMANTrap TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureTrapSequenceNum,
|
||
cpqRackLastEAEEvent,
|
||
cpqRackEventIndicationIdentifier,
|
||
cpqRackEventIndicationTime,
|
||
cpqRackEventDescription,
|
||
cpqRackEventSummary,
|
||
cpqRackEventCategory,
|
||
cpqRackOtherEventCategory,
|
||
cpqRackEventSubCategory,
|
||
cpqRackOtherEventSubCategory,
|
||
cpqRackEventThreshold,
|
||
cpqRackEventTimeWin,
|
||
cpqRackEventActualThreshold,
|
||
cpqRackEventActualTimeWin,
|
||
cpqRackEventProviderVersion,
|
||
cpqHoOsType,
|
||
cpqHoVersion,
|
||
cpqRackNetworkAddresses,
|
||
cpqRackSerialNum,
|
||
cpqRackEventAlertingElementFormat,
|
||
cpqRackEventOtherAlertingElementFormat,
|
||
cpqRackEventImpactedDomain,
|
||
cpqRackEventComplexName,
|
||
cpqRackEventPartitionId,
|
||
cpqRackEventTriggeringLogID,
|
||
cpqRackEventTriggeringLogIDFormat,
|
||
cpqRackHWPartNumber,
|
||
cpqRackHWFirmwareVersion,
|
||
cpqRackHWManufacturer,
|
||
cpqRackHWSerialNumber,
|
||
cpqRackHWFRUDetails,
|
||
cpqRackHWDevicePermanentNameFormat,
|
||
cpqRackHWOtherPermanentNameFormat,
|
||
cpqRackEventAlertType,
|
||
cpqRackEventOtherAlertType,
|
||
cpqRackEventProbableCause,
|
||
cpqRackEventProbableCauseDescription,
|
||
cpqRackEventPerceivedSeverity,
|
||
cpqRackEventOtherSeverity,
|
||
cpqRackEventTrending,
|
||
cpqRackEventRecommendedActions,
|
||
cpqRackEventID,
|
||
cpqRackEventTime,
|
||
cpqRackEventSystemCreationClassName,
|
||
cpqRackEventSystemName,
|
||
cpqRackEventProviderName }
|
||
|
||
DESCRIPTION
|
||
"WSMAN Major trap"
|
||
|
||
--#TYPE "Generic WSMAN Major trap"
|
||
--#SUMMARY "%s"
|
||
--#ARGUMENTS {6}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY NONE
|
||
::= 22081
|
||
|
||
cpqRackCriticalWSMANTrap TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureTrapSequenceNum,
|
||
cpqRackLastEAEEvent,
|
||
cpqRackEventIndicationIdentifier,
|
||
cpqRackEventIndicationTime,
|
||
cpqRackEventDescription,
|
||
cpqRackEventSummary,
|
||
cpqRackEventCategory,
|
||
cpqRackOtherEventCategory,
|
||
cpqRackEventSubCategory,
|
||
cpqRackOtherEventSubCategory,
|
||
cpqRackEventThreshold,
|
||
cpqRackEventTimeWin,
|
||
cpqRackEventActualThreshold,
|
||
cpqRackEventActualTimeWin,
|
||
cpqRackEventProviderVersion,
|
||
cpqHoOsType,
|
||
cpqHoVersion,
|
||
cpqRackNetworkAddresses,
|
||
cpqRackSerialNum,
|
||
cpqRackEventAlertingElementFormat,
|
||
cpqRackEventOtherAlertingElementFormat,
|
||
cpqRackEventImpactedDomain,
|
||
cpqRackEventComplexName,
|
||
cpqRackEventPartitionId,
|
||
cpqRackEventTriggeringLogID,
|
||
cpqRackEventTriggeringLogIDFormat,
|
||
cpqRackHWPartNumber,
|
||
cpqRackHWFirmwareVersion,
|
||
cpqRackHWManufacturer,
|
||
cpqRackHWSerialNumber,
|
||
cpqRackHWFRUDetails,
|
||
cpqRackHWDevicePermanentNameFormat,
|
||
cpqRackHWOtherPermanentNameFormat,
|
||
cpqRackEventAlertType,
|
||
cpqRackEventOtherAlertType,
|
||
cpqRackEventProbableCause,
|
||
cpqRackEventProbableCauseDescription,
|
||
cpqRackEventPerceivedSeverity,
|
||
cpqRackEventOtherSeverity,
|
||
cpqRackEventTrending,
|
||
cpqRackEventRecommendedActions,
|
||
cpqRackEventID,
|
||
cpqRackEventTime,
|
||
cpqRackEventSystemCreationClassName,
|
||
cpqRackEventSystemName,
|
||
cpqRackEventProviderName }
|
||
|
||
DESCRIPTION
|
||
"WSMAN Critical trap"
|
||
|
||
--#TYPE "Generic WSMAN Critical trap"
|
||
--#SUMMARY "%s"
|
||
--#ARGUMENTS {6}
|
||
--#SEVERITY CRITICAL
|
||
--#TIMEINDEX 99
|
||
--#SIMPLE_SEVERITY CRITICAL
|
||
--#HWSTATUS_CATEGORY NONE
|
||
::= 22082
|
||
|
||
cpqRackEnclosureManagerLinkDown TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureManagerLocation,
|
||
cpqRackCommonEnclosureManagerSparePartNumber,
|
||
cpqRackCommonEnclosureManagerSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The Onboard Administrator Network Link is Down.
|
||
|
||
The Onboard Administrator firmware has detected the loss of network link.
|
||
User Action: Check network connection and configurations for the Onboard Administrator."
|
||
|
||
--#TYPE "Onboard Administrator Link Down (22083)"
|
||
--#SUMMARY "Onboard Administrator Link Down."
|
||
--#ARGUMENTS { }
|
||
--#SEVERITY CRITICAL
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY CRITICAL
|
||
--#HWSTATUS_CATEGORY NETWORK
|
||
--#ACTION "Check network connection and configurations for the Onboard Administrator."
|
||
|
||
::= 22083
|
||
|
||
cpqRackEnclosureManagerLinkUp TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureManagerLocation,
|
||
cpqRackCommonEnclosureManagerSparePartNumber,
|
||
cpqRackCommonEnclosureManagerSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The Onboard Administrator Network Link is Up.
|
||
|
||
The Onboard Administrator firmware has detected the presence of network link.
|
||
User Action: None."
|
||
|
||
--#TYPE "Onboard Administrator Link Up (22084)"
|
||
--#SUMMARY "Onboard Administrator Link Up."
|
||
--#ARGUMENTS { }
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY NETWORKK
|
||
|
||
::= 22084
|
||
|
||
cpqRackErsCommFailure TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackCommonEnclosureName,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureSparePartNumber,
|
||
cpqRackErsTransactionType,
|
||
cpqRackErsConnectionModel,
|
||
cpqRackErsFailureCode,
|
||
cpqRackErsRemoteHost }
|
||
|
||
DESCRIPTION
|
||
"The Onboard Administrator to Insight Remote Support or Insight Online communication failed.
|
||
User Action: Please check the connectivity to Insight Remote Support or Insight Online."
|
||
|
||
--#TYPE "Onboard Administrator to Insight Remote Support or Insight Online communication failure (22085)"
|
||
--#SUMMARY "Onboard Administrator in enclosure %s, in rack %s to Insight Remote Support or Insight Online communication failed."
|
||
--#ARGUMENTS {4, 2}
|
||
--#SEVERITY MAJOR
|
||
--#TIMEINDEX 99
|
||
--#STATE DEGRADED
|
||
--#SIMPLE_SEVERITY MAJOR
|
||
--#HWSTATUS_CATEGORY REMOTESUPPORT
|
||
--#ACTION "Please check the connectivity to Insight Remote Support or Insight Online."
|
||
|
||
::= 22085
|
||
|
||
cpqRackPowerSubsystemOverloadConditionRepaired TRAP-TYPE
|
||
ENTERPRISE compaq
|
||
VARIABLES { sysName,
|
||
cpqHoTrapFlags,
|
||
cpqRackName,
|
||
cpqRackUid,
|
||
cpqRackPowerEnclosureName,
|
||
cpqRackCommonEnclosureSparePartNumber,
|
||
cpqRackCommonEnclosureSerialNum,
|
||
cpqRackCommonEnclosureTrapSequenceNum }
|
||
DESCRIPTION
|
||
"The rack power subsystem overload condition repaired."
|
||
|
||
--#TYPE "Rack power subsystem overload condition repaired (22086)"
|
||
--#SUMMARY "The power subsystem overload condition in enclosure %s in rack %s is repaired."
|
||
--#ARGUMENTS {4, 2}
|
||
--#SEVERITY INFORMATIONAL
|
||
--#TIMEINDEX 99
|
||
--#STATE OPERATIONAL
|
||
--#SIMPLE_SEVERITY OK
|
||
--#HWSTATUS_CATEGORY POWER
|
||
|
||
::= 22086
|
||
|
||
END
|
||
|