mibs/MIBS/hp/HP-ICF-8023-RPTR
2023-12-05 12:25:34 +01:00

1510 lines
66 KiB
Plaintext

HP-ICF-8023-RPTR DEFINITIONS ::= BEGIN
IMPORTS
Integer32, Counter32,
OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
DisplayString, TruthValue
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
rptrPortAutoPartitionState
FROM SNMP-REPEATER-MIB -- 802.3 Repeater MIB
rpMauMediaAvailable, rpMauGroupIndex, rpMauPortIndex,
rpMauIndex
FROM MAU-MIB
hpicfObjectModules, hpicfRepeater, hpicf8023RptrTrapsPrefix
FROM HP-ICF-OID;
hpicf8023RptrMib MODULE-IDENTITY
LAST-UPDATED "200011032210Z" -- November 3, 2000
ORGANIZATION "Hewlett Packard Company,
Network Infrastructure Solutions"
CONTACT-INFO
"Hewlett Packard Company
8000 Foothills Blvd.
Roseville, CA 95747"
DESCRIPTION
"This MIB module contains objects that provide
HP-specific extensions to the 802.3 Repeater MIB."
REVISION "200011032210Z" -- November 3, 2000
DESCRIPTION "Updated division name."
REVISION "9807162027Z" -- July 16, 1998
DESCRIPTION
"Added repeater port auto-negotiation objects."
REVISION "9609100219Z" -- September 10, 1996
DESCRIPTION
"Split this MIB module from the former monolithic
hp-icf MIB. Added hpicf8023MultiRptr groups.
Deprecated objects that presumed a single repeater
segment."
REVISION "9402250000Z" -- February 25, 1994
DESCRIPTION
"Initial revision of this MIB module. Released
with the AdvanceStack 10BaseT hubs: HPJ2600A,
HPJ2601A and HPJ2602A and agent module HPJ2603A."
::= { hpicfObjectModules 9 }
hpRptrBasic OBJECT IDENTIFIER ::= { hpicfRepeater 1 }
hpRptrBasicGlobal OBJECT IDENTIFIER ::= { hpRptrBasic 1 }
hpRptrEntityName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
The local name of this repeater. This is the
same value as hpicfEntityName in the case where
there is Distributed Management Protocol to access
this device.
For SNMPv1, this name is appended to the agent
community name to obtain a community name to use
to specify that the agent should proxy to this
repeater. For example, if this agent has a
community with a community name of 'public', and
the value of this object is 'repeater1', the
community 'public/repeater1' will specify that the
agent should proxy to the public community of the
repeater1 box to obtain management information
about this repeater.
If an agent receives a management request where
the localEntity is not specified, it will default
to the local repeater on which this agent is
executing.
This object has been deprecated. Since it is a
scalar, it does not scale to systems containing
multiple repeater segments. In addition, it is only
considered useful in systems supporting the
Distributed Management Chain, which has also been
deprecated."
::= { hpRptrBasicGlobal 1 }
hpRptrThinlanFault OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
When set to 'true' this object causes the Fault
Led to blink if the ThinLan Port is segmented.
This object has been deprecated. It only makes
sense in systems that support a single BNC port."
::= { hpRptrBasicGlobal 2 }
hpRptrSqeEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
When 'true', this flag indicates that SQE has
been detected for the last ten agent transmits and
there is a high probability that the SQE switch on
the transceiver attached to the AUI port is set to
Enabled, when it should be Disabled.
This object has been deprecated, since it presumes
that the system will only have a single AUI port.
It has been replaced by the hpRptrPtSqeEnabled
object."
::= { hpRptrBasicGlobal 3 }
hpRptrRobustHealing OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
When this flag is set to 'true', it enables
robust port healing mode. The 802.3 specification
states that a segmented port is healed by
successfully transmitting or receiving a packet on
the port. This mode disables port healing on
successful packet reception and requires that a
packet be successfully transmitted on a port in
order for a segmented port to be healed."
::= { hpRptrBasicGlobal 4 }
hpRptrBasicGroup OBJECT IDENTIFIER ::= { hpRptrBasic 2 }
hpRptrBasicGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpRptrBasicGroupEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
HP specific extensions to the rptrGroupTable."
::= { hpRptrBasicGroup 1 }
hpRptrBasicGroupEntry OBJECT-TYPE
SYNTAX HpRptrBasicGroupEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
An entry in the table, containing HP extensions
for a specific group."
INDEX { hpRptrGrpGroupIndex }
::= { hpRptrBasicGroupTable 1 }
HpRptrBasicGroupEntry ::=
SEQUENCE {
hpRptrGrpGroupIndex Integer32,
hpRptrGrpPortsAdminStatus OCTET STRING,
hpRptrGrpPortsSegStatus OCTET STRING,
hpRptrGrpPortsMediaAvailable OCTET STRING,
hpRptrGrpPortsLinkbeatEnabled OCTET STRING,
hpRptrGrpPortsOperStatus OCTET STRING
}
hpRptrGrpGroupIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
The group within the repeater for which this
entry contains information. This object has the
same value as the corresponding instance of
rptrGroupIndex."
::= { hpRptrBasicGroupEntry 1 }
hpRptrGrpPortsAdminStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..128))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
The hpRptrGrpPortsAdminStatus is a bit map of the
state of the rptrPortAdminStatus object for all
of the ports in this group. The object has a one
bit for each port for which the value of
rptrPortAdminStatus is equal to 'enabled(1)' and
a zero bit for each port for which the value of
rptrPortAdminStatus is equal to 'disabled(2)'.
The bits are placed into the OCTET STRING in the
following order:
octet 0 octet 1 octet 2 ...
bits 7-0 bits 7-0 bits 7-0 ...
ports 1-8 ports 9-16 ports 17-24 ...
Values of unused bits in the last octet are
undefined."
::= { hpRptrBasicGroupEntry 2 }
hpRptrGrpPortsSegStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..128))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
The hpRptrGrpPortsSegStatus is a bit map of the
state of the rptrPortAutoPartitionState of all of
the ports in this group. The object has a one
bit for each port for which the value of
rptrPortAutoPartitionState is equal to
'notAutoPartitioned(1)' and a zero bit for each
port for which the value of
rptrPortAutoPartitionState is equal to
'autoPartitioned(2)'.
The bits are placed into the OCTET STRING in the
following order:
octet 0 octet 1 octet 2 ...
bits 7-0 bits 7-0 bits 7-0 ...
ports 1-8 ports 9-16 ports 17-24 ...
Values of unused bits in the last octet are
undefined."
::= { hpRptrBasicGroupEntry 3 }
hpRptrGrpPortsMediaAvailable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..128))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
The hpRptrGrpPortsMediaAvailable is a bit map of
the state of the rpMauMediaAvailable object for
all of the ports in this group. The object has a
one bit for each port for which the value of
rpMauMediaAvailable is equal to 'available(3)'
and a zero bit for each port for which the value
of rpMauMediaAvailable is not equal to
'available(3)'.
The bits are placed into the OCTET STRING in the
following order:
octet 0 octet 1 octet 2 ...
bits 7-0 bits 7-0 bits 7-0 ...
ports 1-8 ports 9-16 ports 17-24 ...
Values of unused bits in the last octet are
undefined."
::= { hpRptrBasicGroupEntry 4 }
hpRptrGrpPortsLinkbeatEnabled OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..128))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
The hpRptrGrpPortsLinkbeatEnabled is a bit map of
the state of the hpRptrPtLinkbeatEnable object for
all of the ports in this group. The object has a
one bit for each port for which the value of
hpRptrPtLinkbeatEnable is equal to 'true(1)' and
a zero bit for each port for which the value of
hpRptrPtLinkbeatEnable is equal to 'false(2)'.
The bits are placed into the OCTET STRING in the
following order:
octet 0 octet 1 octet 2 ...
bits 7-0 bits 7-0 bits 7-0 ...
ports 1-8 ports 9-16 ports 17-24 ...
Values of unused bits in the last octet are
undefined."
::= { hpRptrBasicGroupEntry 5 }
hpRptrGrpPortsOperStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..128))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
The hpRptrGrpPortsOperStatus is a bit map of the
state of all hub ports in the group. The object
has a 1 bit for each port that is enabled, not
segmented, and the media is available. Ports on
which these conditions are not true have a 0 bit.
The bits are placed into the OCTET STRING in the
following order:
octet 0 octet 1 octet 2 ...
bits 7-0 bits 7-0 bits 7-0 ...
ports 1-8 ports 9-16 ports 17-24 ...
Values of unused bits in the last octet are
undefined."
::= { hpRptrBasicGroupEntry 6 }
hpRptrBasicPort OBJECT IDENTIFIER ::= { hpRptrBasic 3 }
hpRptrBasicPtTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpRptrBasicPtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"HP specific extensions to the rptrPortTable."
::= { hpRptrBasicPort 1 }
hpRptrBasicPtEntry OBJECT-TYPE
SYNTAX HpRptrBasicPtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table, containing HP extensions
for a specific port."
INDEX { hpRptrPtGroupIndex, hpRptrPtPortIndex }
::= { hpRptrBasicPtTable 1 }
HpRptrBasicPtEntry ::=
SEQUENCE {
hpRptrPtGroupIndex Integer32,
hpRptrPtPortIndex Integer32,
hpRptrPtLinkbeatEnable TruthValue,
hpRptrPtPolarityReversed TruthValue,
hpRptrPtSqeEnabled TruthValue,
hpRptrPtMediaAvailTrapEnable TruthValue,
hpRptrPtLongCableEnable TruthValue
}
hpRptrPtGroupIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The group containing the port for which this
entry contains information. This object has the
same value as the corresponding instance of
rptrPortGroupIndex."
::= { hpRptrBasicPtEntry 1 }
hpRptrPtPortIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port within the group for which this entry
contains information. This object has the same
value as the corresponding instance of
rptrPortIndex."
::= { hpRptrBasicPtEntry 2 }
hpRptrPtLinkbeatEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this flag is set to 'true' the port's link
beat is enabled and when set to 'false' it is
disabled."
::= { hpRptrBasicPtEntry 3 }
hpRptrPtPolarityReversed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to indicate that the hub port
was wired with the positive/negative polarity of
its transmit and receive pairs reversed. Note
that the port will continue to operate in this
state, with the hub inverting the polarity
internally."
::= { hpRptrBasicPtEntry 4 }
hpRptrPtSqeEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When 'true', this flag indicates that SQE has
been detected for the last ten agent transmits and
there is a high probability that the SQE switch on
the transceiver attached to this port is set to
Enabled, when it should be Disabled. This value
can only be 'true' on AUI ports."
::= { hpRptrBasicPtEntry 5 }
hpRptrPtMediaAvailTrapEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether hpicfMediaAvailDetectTrap and
hpicfMediaAvailLostTrap events should be generated
for MAUs attached to this port. This object has the
value of 'false' by default. Setting the value of
this object to 'true' will cause a
hpicfMediaAvailDetectTrap event to be generated
whenever an instance of rpMauMediaAvailable object
associated with a MAU attached to this port enters
the 'available' state, and a hpicfMediaAvailLostTrap
to be generated whenever an instance of the
rpMauMediaAvailable object associated with a MAU
attached to this port exits the 'available' state.
Note that the disposition of these events is
controlled by the RMON eventTable.
We recommend that this object is only be set to
'true' on important ports, such as cascade ports and
ports attached to routers bridges, switches, or
servers. Setting this object to 'true' on other
ports may cause irrelevant traps. For example, it
is unlikely that an administrator would want to
receive a trap every time a user turns their PC off."
::= { hpRptrBasicPtEntry 6 }
hpRptrPtLongCableEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this flag is set to 'true' the port's squelch
level will be reduced to account for extended
distance connections. When set to 'false', this
port's squelch level will be normal. We recommend
that this object only be set to 'true' for ports
that are actually connected to long cables."
::= { hpRptrBasicPtEntry 7 }
hpRptrMonitor OBJECT IDENTIFIER ::= { hpicfRepeater 2 }
hpRptrMonitorGlobal OBJECT IDENTIFIER ::= { hpRptrMonitor 1 }
-- Note: The hpRptrMonitorGlobal counters that are composed of
-- other objects are provided to allow for event testing on
-- global error conditions.
--
-- Note: the hpRptrMonitorGlobal counters have been deprecated.
-- Since they are scalars, they do not scale to systems
-- containing multiple repeater segments. The standard repeater
-- MIB is adding per-repeater counters for collisions, total
-- frames, total octets and total errors. Keeping per-repeater
-- totals of the other counters included here was felt to be
-- overkill. Another factor is that it is quite expensive to
-- maintain global counters in the presence of port mobility, so
-- it made sense to limit the number of total counters to those
-- that would be the most useful for network management. Note
-- that most of the information in these counters is available
-- through other MIBs, such as the RMON etherStats group.
hpRptrMonCounters
OBJECT IDENTIFIER ::= { hpRptrMonitorGlobal 1 }
hpRptrMonGlobalFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
The total number of frames of valid frame length
that have been received on all ports in this
repeater. This counter is the summation of the
values of the rptrMonitorPortReadableFrames
counter for all of the ports in this repeater.
Equivalently, this counter is the summation of the
values of the rptrMonitorGroupTotalFrames counter
for all of the port groups in this repeater."
REFERENCE
"RFC 1516 rptrMonitorPortReadableFrames and
rptrMonitorGroupTotalFrames, and IEEE 802.3 Rptr Mgt,
19.2.6.2, aReadableFrames."
::= { hpRptrMonCounters 1 }
hpRptrMonGlobalOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
The total number of octets contained in the valid
frames that have been received on the ports in
this repeater. This counter is the summation of
the values of the rptrMonitorPortReadableOctets
counter for all of the ports in this repeater.
Equivalently, this counter is the summation of the
values of the rptrMonitorGroupTotalOctets counter
for all of the port groups in this repeater."
REFERENCE
"RFC 1516 rptrMonitorPortReadableOctets and
rptrMonitorGroupTotalOctets, and IEEE 802.3 Rptr Mgt,
19.2.6.2, aReadableOctets."
::= { hpRptrMonCounters 2 }
hpRptrMonGlobalFCSErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
This counter is incremented by one for each frame
received on any port with the FCSError signal
asserted and the FramingError and CollisionEvent
signals deasserted and whose OctetCount is greater
than or equal to minFrameSize and less than or
equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3
Std). This counter is the summation of the values
of the rptrMonitorPortFCSErrors counter for all of
the ports in this repeater."
REFERENCE
"RFC 1516 rptrMonitorPortFCSErrors and IEEE 802.3
Rptr Mgt, 19.2.6.2, aFrameCheckSequenceErrors."
::= { hpRptrMonCounters 3 }
hpRptrMonGlobalAlignmentErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
This counter is incremented by one for each frame
received on any port with the FCSError and
FramingError signals asserted and CollisonEvent
signal deasserted and whose OctetCount is greater
than or equal to minFrameSize and less than or
equal to maxFrameSize (Ref: 4.4.2.1, IEEE 802.3
Std). If hpRptrMonGlobalAlignmentErrors is
incremented, then the hpRptrMonGlobalFCSErorrs
counter shall not be incremented for the same
frame. This counter is the summation of the
values of the rptrMonitorPortAlignmentErrors
counter for all of the ports in this repeater."
REFERENCE
"RFC 1516 rptrMonitorPortAlignmentErrors and IEEE
802.3 Rptr Mgt, 19.2.6.2, aAlignmentErrors."
::= { hpRptrMonCounters 4 }
hpRptrMonGlobalFrameTooLongs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
This counter is incremented by one for each frame
received on any port whose OctetCount is greater
than maxFrameSize (Ref: 4.4.2.1, IEEE 802.3 Std).
If hpRptrMonGlobalFrameTooLongs is incremented,
then neither the hpRptrMonGlobalAlignmentErorrs
nor the hpRptrMonGlobalFCSErrors counter shall be
incremented for the frame. This counter is the
summation of the values of the
rptrMonitorPortFrameTooLongs counter for all of
the ports in this repeater."
REFERENCE
"RFC 1516 rptrMonitorPortFrameTooLongs and IEEE 802.3
Rptr Mgt, 19.2.6.2, aFramesTooLong"
::= { hpRptrMonCounters 5 }
hpRptrMonGlobalShortEvents OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
This counter is incremented by one for each
CarrierEvent on any port with ActivityDuration
less than ShortEventMaxTime. ShortEventMaxTime is
greater than 74 bit times and less than 82 bit
times. ShortEventMaxTime has tolerances included
to provide for circuit losses between a
conformance test point at the AUI and the
measurement point within the state machine. This
counter is the summation of the values of the
rptrMonitorPortShortEvents counter for all of the
ports in this repeater."
REFERENCE
"RFC 1516 rptrMonitorPortShortEvents and IEEE 802.3
Rptr Mgt, 19.2.6.2, aShortEvents."
::= { hpRptrMonCounters 6 }
hpRptrMonGlobalRunts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
This counter is incremented by one for each
CarrierEvent on any port that meets one of the
following two conditions. Only one test need be
made. a) The ActivityDuration is greater than
ShortEventMaxTime and less than ValidPacketMinTime
and the CollisionEvent signal is deasserted. b)
The OctetCount is less than 64, the
ActivityDuration is greater than ShortEventMaxTime
and the CollisionEvent signal is deasserted.
ValidPacketMinTime is greater than or equal to 552
bit times but less than 565 bit times.
An event whose length is greater than 74 bit times
but less than 82 bit times shall increment either
the hpRptrMonGlobalShortEvents counter or the
hpRptrMonGlobalRunts counter but not both. A
CarrierEvent greater than or equal to 552 bit
times but less than 565 bit times may or may not
increment the hpRptrMonGlobalRunts counter.
ValidPacketMinTime has tolerances included to
provide for circuit losses between a conformance
test point at the AUI and the measurement point
within the state machine.
Runts usually indicate collision fragments, a
normal network event. This counter is the
summation of the values of the
rptrMonitorPortRunts counter for all of the ports
in this repeater."
REFERENCE
"RFC 1516 rptrMonitorPortRunts and IEEE 802.3 Rptr
Mgt, 19.2.6.2, aRunts."
::= { hpRptrMonCounters 7 }
hpRptrMonGlobalCollisions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
This counter is incremented by one for any
CarrierEvent signal on any port for which the
CollisionEvent signal on any port is asserted.
This counter differs from
rptrMonitorTransmitCollisions in that it counts
all collisions seen by this repeater, even those
involving only a single port on this repeater,
whereas rptrMonitorTransmitCollisions counts only
collisions involving multiple ports on this
repeater."
REFERENCE
"RFC 1516 rptrMonitorPortCollisions and IEEE 802.3
Rptr Mgt, 19.2.6.2, aCollisions."
::= { hpRptrMonCounters 8 }
hpRptrMonGlobalLateEvents OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
This counter is incremented by one for each
CarrierEvent on any port in which the CollIn(X)
variable transitions to the value SQE (Ref:
9.6.6.2, IEEE 802.3 Std) while the
ActivityDuration is greater than the
LateEventThreshold. Such a CarrierEvent is
counted twice, as both hpRptrMonGlobalCollisions
and hpRptrMonGlobalLateEvents. The
LateEventThreshold is greater than 480 bit times
and less than 565 bit times. LateEventThreshold
has tolerances included to permit an
implementation to build a single threshold to
serve as both the LateEventThreshold and
ValidPacketMinTime threshold. This counter is the
summation of the values of the
rptrMonitorPortLateEvents counter for all of the
ports in this repeater."
REFERENCE
"RFC 1516 rptrMonitorPortLateEvents and IEEE 802.3
Rptr Mgt, 19.2.6.2, aLateEvents."
::= { hpRptrMonCounters 9 }
hpRptrMonGlobalVeryLongEvents OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
This counter is incremented by one for each
CarrierEvent on any port whose ActivityDuration is
greater than the MAU Jabber Lockup Protection
timer TW3 (Ref: 9.6.1 & 9.6.5, IEEE 802.3 Std).
Other counters may be incremented as appropriate.
This counter is the summation of the values of the
rptrMonitorPortVeryLongEvents counter for all of
the ports in this repeater."
REFERENCE
"RFC 1516 rptrMonitorPortVeryLongEvents and IEEE
802.3 Rptr Mgt, 19.2.6.2, aVeryLongEvents."
::= { hpRptrMonCounters 10 }
hpRptrMonGlobalDataRateMismatches OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
This counter is incremented by one for each frame
received on any port that meets all of the
following conditions: a) The CollisionEvent
signal is not asserted. b) The ActivityDuration
is greater than ValidPacketMinTime. c) The
frequency (data rate) is detectably mismatched
from the local transmit frequency. The exact
degree of mismatch is vendor specific and is to be
defined by the vendor for conformance testing.
When this event occurs, other counters whose
increment conditions were satisfied may or may not
also be incremented. This counter is the
summation of the values of the
rptrMonitorPortDatRateMismatches counter for all
of the ports in this repeater."
REFERENCE
"RFC 1516 rptrMonitorPortDataRateMismatches and IEEE
802.3 Rptr Mgt, 19.2.6.2, aDataRateMismatches."
::= { hpRptrMonCounters 11 }
hpRptrMonGlobalAutoPartitions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
This counter is incremented by one for each time
the repeater has automatically partitioned any
port. The conditions that cause port partitioning
are specified in the partition state machine in
Section 9 of the IEEE 802.3 Std. This counter is
the summation of the values of the
rptrMonitorPortAutoPartitions for all of the ports
in this repeater."
REFERENCE
"RFC 1516 rptrMonitorPortAutoPartitions and IEEE
802.3 Rptr Mgt, 19.2.6.2, aAutoPartitions."
::= { hpRptrMonCounters 12 }
hpRptrMonGlobalErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
The total number of errors which have occured
on any port in this repeater. This counter is
the summation of the values of other error
counters, namely:
hpRptrMonGlobalFCSErrors,
hpRptrMonGlobalAlignmentErrors,
hpRptrMonGlobalFrameTooLongs,
hpRptrMonGlobalShortEvents,
hpRptrMonGlobalLateEvents,
hpRptrMonGlobalVeryLongEvents, and
hpRptrMonGlobalDataRateMismatches.
Equivalently, this counter is the summation of
the values of the rptrMonitorPortTotalErrors
counter for all of the ports in this repeater, or
it is the summation of the values of
rptrMonitorGroupTotalErrors for all of the port
groups in this repeater."
REFERENCE
"RFC 1516, rptrMonitorGroupTotalErrors and
hpRptrMonitorPortTotalErrors."
::= { hpRptrMonCounters 13 }
hpRptrMonGlobalUcastPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
This counter is incremented by one for each
unicast packet of valid frame length received on
any port. This counter is the summation of
hpRptrMonPortUcastPackets for all of the ports
in this repeater. This counter may not be
implemented for repeaters which do not have a
local network management agent."
::= { hpRptrMonCounters 14 }
hpRptrMonGlobalBcastPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
This counter is incremented by one for each
broadcast packet of valid frame length received on
any port. This counter is the summation of
hpRptrMonPortBcastPackets for all of the ports
in this repeater. This counter may not be
implemented for repeaters which do not have a
local network management agent."
::= { hpRptrMonCounters 15 }
hpRptrMonGlobalMcastPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"********* THIS OBJECT IS DEPRECATED *********
This counter is incremented by one for each
multicast packet of valid frame length received on
any port. This counter is the summation of
hpRptrMonPortMcastPackets for all of the ports in
this repeater. This counter may not be
implemented for repeaters which do not have a
local network management agent."
::= { hpRptrMonCounters 16 }
hpRptrMonitorGroup
OBJECT IDENTIFIER ::= { hpRptrMonitor 2 } -- unused
hpRptrMonitorPort
OBJECT IDENTIFIER ::= { hpRptrMonitor 3 }
hpRptrMonPtTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpRptrMonPtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of HP specific per port monitor objects."
::= { hpRptrMonitorPort 1 }
hpRptrMonPtEntry OBJECT-TYPE
SYNTAX HpRptrMonPtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table, containing per port
objects for a single port."
INDEX { hpRptrMonPtGroupIndex, hpRptrMonPtPortIndex }
::= { hpRptrMonPtTable 1 }
HpRptrMonPtEntry ::=
SEQUENCE {
hpRptrMonPtGroupIndex Integer32,
hpRptrMonPtPortIndex Integer32,
hpRptrMonPtUcastPackets Counter32,
hpRptrMonPtBcastPackets Counter32,
hpRptrMonPtMcastPackets Counter32
}
hpRptrMonPtGroupIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The group containing the port for which this
entry contains information. This object has the
same value as the corresponding instance of
rptrMonitorPortGroupIndex."
::= { hpRptrMonPtEntry 1 }
hpRptrMonPtPortIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port within the group for which this entry
contains information. This object has the same
value as the corresponding instance of
rptrMonitorPortIndex."
::= { hpRptrMonPtEntry 2 }
hpRptrMonPtUcastPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented by one for each
unicast packet of valid frame length received on
this port. This object may not be implemented for
repeaters which do not have a local network
management agent."
::= { hpRptrMonPtEntry 3 }
hpRptrMonPtBcastPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented by one for each
broadcast packet of valid frame length received on
this port. This object may not be implemented for
repeaters which do not have a local network
management agent."
::= { hpRptrMonPtEntry 4 }
hpRptrMonPtMcastPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented by one for each
multicast packet of valid frame length received on
this port. This object may not be implemented for
repeaters which do not have a local network
management agent."
::= { hpRptrMonPtEntry 5 }
hpRpMauGroup OBJECT IDENTIFIER ::= { hpicfRepeater 4 }
hpRpMauTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpRpMauEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"HP extensions to the rpMauTable."
::= { hpRpMauGroup 1 }
hpRpMauEntry OBJECT-TYPE
SYNTAX HpRpMauEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table, containing HP extensions
for a single MAU."
INDEX { rpMauGroupIndex, rpMauPortIndex, rpMauIndex }
::= { hpRpMauTable 1 }
HpRpMauEntry ::=
SEQUENCE {
hpRpMauTypeList BITS,
hpRpMauAutoNegSupported TruthValue,
hpRpMauAutoNegAdminStatus INTEGER,
hpRpMauAutoNegRemoteSignaling INTEGER,
hpRpMauAutoNegConfig INTEGER,
hpRpMauAutoNegCapReceived BITS,
hpRpMauAutoNegRestart INTEGER
}
hpRpMauTypeList OBJECT-TYPE
SYNTAX BITS {
bOther(0), -- other or unknown
bAUI(1), -- AUI
b10base5(2), -- 10BASE-5
bFoirl(3), -- FOIRL
b10base2(4), -- 10BASE-2
b10baseT(5), -- 10BASE-T duplex mode unknown
b10baseFP(6), -- 10BASE-FP
b10baseFB(7), -- 10BASE-FB
b10baseFL(8), -- 10BASE-FL duplex mode unknown
b10broad36(9), -- 10BROAD36
b10baseTHD(10), -- 10BASE-T half duplex mode
b10baseTFD(11), -- 10BASE-T full duplex mode
b10baseFLHD(12), -- 10BASE-FL half duplex mode
b10baseFLFD(13), -- 10BASE-FL full duplex mode
b100baseT4(14), -- 100BASE-T4
b100baseTXHD(15), -- 100BASE-TX half duplex mode
b100baseTXFD(16), -- 100BASE-TX full duplex mode
b100baseFXHD(17), -- 100BASE-FX half duplex mode
b100baseFXFD(18), -- 100BASE-FX full duplex mode
b100baseT2HD(19), -- 100BASE-T2 half duplex mode
b100baseT2FD(20) -- 100BASE-T2 full duplex mode
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A value that uniquely identifies the set of
possible IEEE 802.3 types that the MAU could be. If
auto-negotiation is present on this MAU, this object
will map to hpRpMauAutoNegCapability.
Note that a repeater can never actually support the
full-duplex MAU types. The bits for them are
retained to keep the bit values consistent with
ifMauTypeListBits."
::= { hpRpMauEntry 1 }
hpRpMauAutoNegSupported OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates whether or not
auto-negotiation is supported on this MAU."
::= { hpRpMauEntry 2 }
hpRpMauAutoNegAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
autoNegotiate(1),
forceTo100TXHD(2),
forceTo10THD(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to autoNegotiate(1) will cause
auto-negotiation to be enabled on this port.
Setting this object to forceTo100TXHD will cause
auto-negotiation to be disabled on this port, and
cause the operational type of the MAU on this port
(as reported by rpMauType) to transition to
dot3MauType100BaseTXHD.
Setting this object to forceTo10THD will cause
auto-negotiation to be disabled on this port, and
cause the operational type of the MAU on this port
(as reported by rpMauType) to transition to
dot3MauType10BaseTHD."
::= { hpRpMauEntry 3 }
hpRpMauAutoNegRemoteSignaling OBJECT-TYPE
SYNTAX INTEGER {
detected(1),
notdetected(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A value indicating whether the remote end of the
link is using auto-negotiation signaling. It takes
the value detected(1) if and only if, during the
previous link negotiation, FLP Bursts were received."
REFERENCE "[IEEE 802.3 Mgt], 30.6.1.1.3,
aAutoNegRemoteSignaling."
::= { hpRpMauEntry 4 }
hpRpMauAutoNegConfig OBJECT-TYPE
SYNTAX INTEGER {
other(1),
configuring(2),
complete(3),
disabled(4),
parallelDetectFail(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A value indicating the current status of the
auto-negotiation process. The enumeration
parallelDetectFail(5) maps to a failure in parallel
detection as defined in 28.2.3.1 of
[IEEE 802.3 Std]."
REFERENCE "[IEEE 802.3 Mgt], 30.6.1.1.4,
aAutoNegAutoConfig."
::= { hpRpMauEntry 5 }
hpRpMauAutoNegCapReceived OBJECT-TYPE
SYNTAX BITS {
bOther(0), -- other or unknown
b10baseT(1), -- 10BASE-T half duplex mode
b10baseTFD(2), -- 10BASE-T full duplex mode
b100baseT4(3), -- 100BASE-T4
b100baseTX(4), -- 100BASE-TX half duplex mode
b100baseTXFD(5), -- 100BASE-TX full duplex mode
b100baseT2(6), -- 100BASE-T2 half duplex mode
b100baseT2FD(7) -- 100BASE-T2 full duplex mode
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A value that uniquely identifies the set of
capabilities received from the remote
auto-negotiation entity.
Note that ports that support this MIB may be
attached to remote auto-negotiation entities which
have capabilities beyond the scope of this MIB."
REFERENCE "[IEEE 802.3 Mgt], 30.6.1.1.7,
aAutoNegReceivedTechnologyAbility."
::= { hpRpMauEntry 6 }
hpRpMauAutoNegRestart OBJECT-TYPE
SYNTAX INTEGER {
restart(1),
norestart(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If the value of this object is set to restart(1)
then this will force auto-negotiation to begin link
renegotiation. If auto-negotiation signaling is
disabled, a write to this object has no effect.
Setting the value of this object to norestart(2) has
no effect."
REFERENCE "[IEEE 802.3 Mgt], 30.6.1.2.1,
acAutoNegRestartAutoConfig."
::= { hpRpMauEntry 7 }
-- 802.3 Repeater Specific Traps
hpicfLinkBeatTrap NOTIFICATION-TYPE
OBJECTS { rpMauMediaAvailable }
STATUS deprecated
DESCRIPTION
"********* THIS NOTIFICATION IS DEPRECATED *********
A hpicfLinkBeatTrap is device type specific to ICF
hubs. It signifies that the hub hardware has
detected a change of state in a port's link beat
status. The current value of the port's link beat
status is returned in the PDU.
This trap has been deprecated. It is replaced by the
hpicfMediaAvailDetectTrap and the
hpicfMediaAvailLostTrap."
::= { hpicf8023RptrTrapsPrefix 1 }
hpicfPartitionTrap NOTIFICATION-TYPE
OBJECTS { rptrPortAutoPartitionState }
STATUS deprecated
DESCRIPTION
"********* THIS NOTIFICATION IS DEPRECATED *********
A hpicfPartitionTrap is device type specific to ICF
hubs. It signifies that the hub hardware has
detected a change of state in a port's partition
status. The current value of the port's partition
status is returned in the PDU.
This trap has been deprecated. It is replaced by the
hpicfPortPartitionTrap and the hpicfPortHealTrap."
::= { hpicf8023RptrTrapsPrefix 2 }
hpicfMediaAvailDetectTrap NOTIFICATION-TYPE
OBJECTS { rpMauMediaAvailable }
STATUS current
DESCRIPTION
"A hpicfMediaAvailDetectTraps is device type specific
to ICF hubs. It signifies that the hub hardware has
detected an instance of rpMauMediaAvailable for one
of the repeater's ports has entered the 'available'
state from some other state. Note that this trap is
only generated for instances of rpMauMediaAvailable
associated with MAUs attached to repeater ports for
which the corresponding instance of the
hpRptrPtMediaAvailTrapEnable object is equal to
'true'.
The previous value of the instance of the
rpMauMediaAvailable object that entered the 'active'
state is returned in the PDU."
::= { hpicf8023RptrTrapsPrefix 3 }
hpicfMediaAvailLostTrap NOTIFICATION-TYPE
OBJECTS { rpMauMediaAvailable }
STATUS current
DESCRIPTION
"A hpicfMediaAvailLostTraps is device type specific
to ICF hubs. It signifies that the hub hardware has
detected an instance of rpMauMediaAvailable for one
of the repeater's ports that had been in the
'available' state has exited that state. Note that
this trap is only generated for instances of
rpMauMediaAvailable associated with MAUs attached to
repeater ports for which the corresponding instance
of the hpRptrPtMediaAvailTrapEnable object is equal
to 'true'.
The new value of the instance of the
rpMauMediaAvailable object that exited the 'active'
state is returned in the PDU."
::= { hpicf8023RptrTrapsPrefix 4 }
hpicfPortPartitionTrap NOTIFICATION-TYPE
OBJECTS { rptrPortAutoPartitionState }
STATUS current
DESCRIPTION
"A hpicfPortPartitionTrap is device type specific
to ICF hubs. It signifies that the hub hardware has
detected that an instance of
rptrPortAutoPartitionState for one of the repeater's
ports has changed from the 'notAutoPartitioned' state
to the 'autoPartitioned' state. The current value of
the instance of the rptrPortAutoPartitionState for
the port that auto-partitioned is returned in the
PDU."
::= { hpicf8023RptrTrapsPrefix 5 }
hpicfPortHealTrap NOTIFICATION-TYPE
OBJECTS { rptrPortAutoPartitionState }
STATUS current
DESCRIPTION
"A hpicfPortHealTrap is device type specific to ICF
hubs. It signifies that the hub hardware has
detected that an instance of
rptrPortAutoPartitionState for one of the repeater's
ports has changed from the 'autoPartitioned' state
to the 'notAutoPartitioned' state. The current value
of the instance of the rptrPortAutoPartitionState for
the port that healed is returned in the PDU."
::= { hpicf8023RptrTrapsPrefix 6 }
-- Conformance information
hpicf8023RptrConformance
OBJECT IDENTIFIER ::= { hpicf8023RptrMib 1 }
hpicf8023RptrCompliances
OBJECT IDENTIFIER ::= { hpicf8023RptrConformance 1 }
hpicf8023RptrGroups
OBJECT IDENTIFIER ::= { hpicf8023RptrConformance 2 }
-- Compliance statements
hpicf8023RptrCompliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"********* THIS COMPLIANCE IS DEPRECATED *********
The compliance statement for HP extensions to the
802.3 Repeater MIB for HP AdvanceStack 802.3
repeaters."
MODULE
MANDATORY-GROUPS { hpicf8023RptrBasicGroup,
hpicf8023RptrMonitorGroup,
hpicf8023RptrNotifyGroup }
::= { hpicf8023RptrCompliances 1 }
hpicf8023RptrSlaveCompliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"********* THIS COMPLIANCE IS DEPRECATED *********
The compliance statement for HP extensions to the
802.3 Repeater MIB for HP AdvanceStack 802.3
slave repeaters."
MODULE
MANDATORY-GROUPS { hpicf8023RptrBasicSlaveGroup,
hpicf8023RptrMonitorSlaveGroup,
hpicf8023RptrNotifyGroup }
::= { hpicf8023RptrCompliances 2 }
hpicf8023MultiRptrCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for HP extensions to the
802.3 Repeater MIB for HP AdvanceStack 802.3
repeaters. This compliance supports devices
with multiple repeater segments, as well as
devices with a single repeater segment."
MODULE
MANDATORY-GROUPS { hpicf8023MultiRptrBasicGroup,
hpicf8023MultiRptrMonitorGroup,
hpicf8023MultiRptrNotifyGroup }
::= { hpicf8023RptrCompliances 3 }
hpicf8023RptrAutoNegCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for HP extensions to the
802.3 Repeater MIB for HP AdvanceStack 802.3
repeaters. This compliance supports devices
with multiple repeater segments, as well as
devices with a single repeater segment. It also
supports repeater devices with auto-negotiation."
MODULE
MANDATORY-GROUPS { hpicf8023MultiRptrBasicGroup,
hpicf8023MultiRptrMonitorGroup,
hpicf8023MultiRptrNotifyGroup }
GROUP hpicf8023RpMauAutoNegGroup
DESCRIPTION "Implementation of this group is required for
MAUs that support auto-negotiation."
::= { hpicf8023RptrCompliances 4 }
-- Units of conformance
hpicf8023RptrBasicGroup OBJECT-GROUP
OBJECTS { hpRptrEntityName,
hpRptrThinlanFault,
hpRptrSqeEnabled,
hpRptrRobustHealing,
hpRptrGrpGroupIndex,
hpRptrGrpPortsAdminStatus,
hpRptrGrpPortsSegStatus,
hpRptrGrpPortsMediaAvailable,
hpRptrGrpPortsLinkbeatEnabled,
hpRptrGrpPortsOperStatus,
hpRptrPtGroupIndex,
hpRptrPtPortIndex,
hpRptrPtLinkbeatEnable,
hpRptrPtPolarityReversed
}
STATUS deprecated
DESCRIPTION
"********* THIS GROUP IS DEPRECATED *********
A collection of HP specific extensions to the
802.3 Repeater MIB for the HP AdvanceStack product
line."
::= { hpicf8023RptrGroups 1 }
hpicf8023RptrBasicSlaveGroup OBJECT-GROUP
OBJECTS { hpRptrEntityName,
hpRptrThinlanFault,
hpRptrSqeEnabled,
hpRptrGrpGroupIndex,
hpRptrGrpPortsAdminStatus,
hpRptrGrpPortsSegStatus,
hpRptrGrpPortsMediaAvailable,
hpRptrGrpPortsLinkbeatEnabled,
hpRptrGrpPortsOperStatus,
hpRptrPtGroupIndex,
hpRptrPtPortIndex,
hpRptrPtLinkbeatEnable,
hpRptrPtPolarityReversed
}
STATUS deprecated
DESCRIPTION
"********* THIS GROUP IS DEPRECATED *********
A collection of HP specific extensions to the
802.3 Repeater MIB for HP AdvanceStack slaves."
::= { hpicf8023RptrGroups 2 }
hpicf8023RptrMonitorGroup OBJECT-GROUP
OBJECTS { hpRptrMonGlobalFrames,
hpRptrMonGlobalOctets,
hpRptrMonGlobalFCSErrors,
hpRptrMonGlobalAlignmentErrors,
hpRptrMonGlobalFrameTooLongs,
hpRptrMonGlobalShortEvents,
hpRptrMonGlobalRunts,
hpRptrMonGlobalCollisions,
hpRptrMonGlobalLateEvents,
hpRptrMonGlobalVeryLongEvents,
hpRptrMonGlobalDataRateMismatches,
hpRptrMonGlobalAutoPartitions,
hpRptrMonGlobalErrors,
hpRptrMonGlobalUcastPackets,
hpRptrMonGlobalBcastPackets,
hpRptrMonGlobalMcastPackets,
hpRptrMonPtGroupIndex,
hpRptrMonPtPortIndex,
hpRptrMonPtUcastPackets,
hpRptrMonPtBcastPackets,
hpRptrMonPtMcastPackets
}
STATUS deprecated
DESCRIPTION
"********* THIS GROUP IS DEPRECATED *********
A collection of extended counters for 802.3
repeaters in the HP AdvanceStack product line."
::= { hpicf8023RptrGroups 3 }
hpicf8023RptrMonitorSlaveGroup OBJECT-GROUP
OBJECTS { hpRptrMonGlobalFrames,
hpRptrMonGlobalOctets,
hpRptrMonGlobalFCSErrors,
hpRptrMonGlobalAlignmentErrors,
hpRptrMonGlobalFrameTooLongs,
hpRptrMonGlobalShortEvents,
hpRptrMonGlobalRunts,
hpRptrMonGlobalCollisions,
hpRptrMonGlobalLateEvents,
hpRptrMonGlobalVeryLongEvents,
hpRptrMonGlobalDataRateMismatches,
hpRptrMonGlobalAutoPartitions,
hpRptrMonGlobalErrors
}
STATUS deprecated
DESCRIPTION
"********* THIS GROUP IS DEPRECATED *********
A collection of extended counters for HP
AdvanceStack 802.3 slave repeaters."
::= { hpicf8023RptrGroups 4 }
hpicf8023MultiRptrBasicGroup OBJECT-GROUP
OBJECTS { hpRptrPtGroupIndex,
hpRptrPtPortIndex,
hpRptrPtLinkbeatEnable,
hpRptrPtPolarityReversed,
hpRptrPtSqeEnabled,
hpRptrPtMediaAvailTrapEnable,
hpRptrPtLongCableEnable
}
STATUS current
DESCRIPTION
"A collection of HP specific extensions to the
802.3 Repeater MIB for products in the HP
AdvanceStack product line. This group supports
devices with multiple repeater segments as well
as devices with a single repeater segment."
::= { hpicf8023RptrGroups 5 }
hpicf8023MultiRptrMonitorGroup OBJECT-GROUP
OBJECTS { hpRptrMonPtGroupIndex,
hpRptrMonPtPortIndex,
hpRptrMonPtUcastPackets,
hpRptrMonPtBcastPackets,
hpRptrMonPtMcastPackets
}
STATUS current
DESCRIPTION
"A collection of extended counters for 802.3
repeaters in the HP AdvanceStack product line.
This group supports devices with multiple
repeater segments as well as devices with a
single repeater segment."
::= { hpicf8023RptrGroups 6 }
hpicf8023RptrNotifyGroup NOTIFICATION-GROUP
NOTIFICATIONS { hpicfLinkBeatTrap,
hpicfPartitionTrap
}
STATUS deprecated
DESCRIPTION
"********* THIS GROUP IS DEPRECATED *********
A collection of notifications used to indicate
changes in port status for 802.3 repeaters in the
HP AdvanceStack product line."
::= { hpicf8023RptrGroups 7 }
hpicf8023MultiRptrNotifyGroup NOTIFICATION-GROUP
NOTIFICATIONS { hpicfMediaAvailDetectTrap,
hpicfMediaAvailLostTrap,
hpicfPortPartitionTrap,
hpicfPortHealTrap
}
STATUS current
DESCRIPTION
"A collection of notifications used to indicate
changes in port status for 802.3 repeaters in the
HP AdvanceStack product line. Notifications in
this group use different traps for good->bad than
are used for bad->good (similar to linkUp/linkDown)."
::= { hpicf8023RptrGroups 8 }
hpicf8023RpMauAutoNegGroup OBJECT-GROUP
OBJECTS { hpRpMauTypeList,
hpRpMauAutoNegSupported,
hpRpMauAutoNegAdminStatus,
hpRpMauAutoNegRemoteSignaling,
hpRpMauAutoNegConfig,
hpRpMauAutoNegCapReceived,
hpRpMauAutoNegRestart
}
STATUS current
DESCRIPTION
"A collection of objects for managing MAUs attached
to repeater ports with managed auto-negotiation."
::= { hpicf8023RptrGroups 9 }
hpicf8023Rptr100BasicGroup OBJECT-GROUP
OBJECTS { hpRptrPtGroupIndex,
hpRptrPtPortIndex,
hpRptrPtPolarityReversed,
hpRptrPtMediaAvailTrapEnable
}
STATUS current
DESCRIPTION
"A collection of HP specific extensions to the
802.3 Repeater MIB for products in the HP
AdvanceStack product line. This group supports
devices with multiple repeater segments as well
as devices with a single repeater segment. This
group supports devices with 100BaseT repeater
segments."
::= { hpicf8023RptrGroups 10 }
END