mibs/MIBS/hp/HP-SN-SWITCH-GROUP-MIB
2023-12-05 12:25:34 +01:00

5866 lines
156 KiB
Plaintext

HP-SN-SWITCH-GROUP-MIB DEFINITIONS ::= BEGIN
-- Foundry SnSwitch Group MIB Release 2.0.0
-- Revision 0 08/18/96
-- Copyright 1996-97 Foundry Networks, Inc.
-- All rights reserved.
-- This Foundry Networks SNMP Management Information Base Specification
-- (Specification) embodies Foundry Networks' confidential and
-- proprietary intellectual property. Foundry Networks retains all
-- title and ownership in the Specification, including any
-- revisions.
-- This Specification is supplied "AS IS," and Foundry Networks makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.
-- SECTION 1: Top Level Definitions
-- Imports
IMPORTS
Counter, TimeTicks, IpAddress, Gauge
FROM RFC1155-SMI
Unsigned32
FROM SNMPv2-SMI
OBJECT-TYPE
FROM RFC-1212
snSwitch
FROM HP-SN-ROOT-MIB;
-- textual conventions
DisplayString ::=
OCTET STRING
-- This data type is used to model textual information taken
-- from the NVT ASCII character set. By convention, objects
-- with this syntax are declared as having
--
-- SIZE (0..255)
PhysAddress ::=
OCTET STRING
-- This data type is used to model media addresses. For many
-- types of media, this will be in a binary representation.
-- For example, an ethernet address would be represented as
-- a string of 6 octets.
MacAddress ::=
OCTET STRING (SIZE(6))
-- This data type is used to model media addresses. For many
-- types of media, this will be in a binary representation.
-- For example, an ethernet address would be represented as
-- a string of 6 octets.
BridgeId ::= OCTET STRING (SIZE(8))
-- the Bridge-Identifier as used in the Spanning Tree
Timeout ::= INTEGER -- a STP timer in units of 1/100 seconds
PortMask ::=
INTEGER
-- This data type is used to model port bitmask. The
-- maximum of ports are 32.
InterfaceId ::= OBJECT IDENTIFIER
-- This data type is used to specify an interface ID.
-- The first object identifier is port type, and the
-- format of the rest of the object identifiers depend
-- on the port type.
--
-- ethernet(1), format: type.slot.port
-- e.g. 1.3.6 is port ethernet 3/6
--
-- pos(2), format: type.slot.port
-- e.g. 2.10.1 is port pos 10/1
--
-- atm(3), format: type.slot.port
-- e.g. 3.8.2 is port atm 8/2
--
-- virtual router interface(4), format: type.ve
-- e.g. 4.9 is port ve 9
--
-- loopback(5), format: type.lb
-- e.g. 5.7 is port loopback 7
--
-- gre tunnel(6), format: type.tn, not supported
--
-- subinterface(7), format: type.slot.port.subInterface
-- e.g. 7.3.2.4 is port atm 3/2.4
--
-- mpls tunnel(8), format: type.tn
-- e.g. 8.3 is port tunnel 3
--
-- pvc(9), format: type.slot.port.subInterface.vpi.vci
-- e.g. 9.3.1.2.1.2 is port atm 3/1.2.1.2
-- Groups
snSwInfo OBJECT IDENTIFIER ::= { snSwitch 1 }
snVLanInfo OBJECT IDENTIFIER ::= { snSwitch 2 }
snSwPortInfo OBJECT IDENTIFIER ::= { snSwitch 3 }
snFdbInfo OBJECT IDENTIFIER ::= { snSwitch 4 }
snPortStpInfo OBJECT IDENTIFIER ::= { snSwitch 5 }
snTrunkInfo OBJECT IDENTIFIER ::= { snSwitch 6 }
snSwSummary OBJECT IDENTIFIER ::= { snSwitch 7 }
snDhcpGatewayListInfo OBJECT IDENTIFIER ::= { snSwitch 8 }
snDnsInfo OBJECT IDENTIFIER ::= { snSwitch 9 }
snMacFilter OBJECT IDENTIFIER ::= { snSwitch 10 }
snNTP OBJECT IDENTIFIER ::= { snSwitch 11 }
snRadius OBJECT IDENTIFIER ::= { snSwitch 12 }
snTacacs OBJECT IDENTIFIER ::= { snSwitch 13 }
snQos OBJECT IDENTIFIER ::= { snSwitch 14 }
snAAA OBJECT IDENTIFIER ::= { snSwitch 15 }
snCAR OBJECT IDENTIFIER ::= { snSwitch 16 }
snVLanCAR OBJECT IDENTIFIER ::= { snSwitch 17 }
snNetFlow OBJECT IDENTIFIER ::= { snSwitch 18 }
snSFlow OBJECT IDENTIFIER ::= { snSwitch 19 }
snFDP OBJECT IDENTIFIER ::= { snSwitch 20 }
snVsrp OBJECT IDENTIFIER ::= { snSwitch 21 }
-- SECTION 2: Switch Group Configuration MIBs
snSwGroupOperMode OBJECT-TYPE
SYNTAX INTEGER {
noVLan(1),
vlanByPort(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"noVLan(1) represents all switch ports with no virtual
LAN by port (no Port VLAN), and with no tag assigned.
vlanByPort(2) represents all switch ports with Basic
VLAN (layer2 Switch). "
::= { snSwInfo 1 }
snSwGroupIpL3SwMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Switch Group is configured with the Layer3
IP Switch mode either enabled or disabled and the
default is disabled mode.
enabled(1)...........activate Layer3 IP Switch
disabled(0)..........disable Layer3 IP Switch"
::= { snSwInfo 2 }
snSwGroupIpMcastMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Switch Group is configured with the IP Multicast
pruning mode either enabled or disabled and the
default is disabled mode.
enabled(1)...........activate IP Multicast pruning
disabled(0)..........no IP Multicast pruning"
::= { snSwInfo 3 }
snSwGroupDefaultCfgMode OBJECT-TYPE
SYNTAX INTEGER {
default(1),
nonDefault(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Switch Group is configured with the Default
configuration. If the default configuration gets
overwritten, the state will change to non-default.
default(1)...........default configuration
nonDefault(2)..........non default configuration"
::= { snSwInfo 4 }
snSwGroupSwitchAgeTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Switch Age time is 180sec by default.
The configured range is 10 to 10,000sec. The time
represents the time span to age out an MAC Address
entry."
::= { snSwInfo 5 }
snVLanGroupVlanCurEntry OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current total entry number of VLANs are configured."
::= { snSwInfo 6 }
snVLanGroupSetAllVLan OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of this object is the VLanIndex of a particalur
entry in snVLanByPortTable (snVLanByPortVLanIndex).
All the attributes of that row of table except PortMask
will be used to set the same attributes for the
entire VLan group. VLanId and PortMask must be set for
that particular entry prior to setting this object.
Switch software will base on that VLAN information
to set the entire VLAN.
Note: All the intended attributes of the given
row of the table (given VLAN) must be set prior
setting this object. When this object is set,
Set-All-VLAN action will take place simultaneously.
The previous setting will be overwritten by the
new one."
::= { snSwInfo 7 }
snSwPortSetAll OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of this object is the index number of the
snSwPortInfoTable (snSwPortInfoPortIndex).
snSwPortInfoMonitorMode, snSwPortInfoTagMode,
snSwPortInfoChnMode, snSwPortInfoSpeed,
snSwPortInfoAdminStatus are all the
read-write attributes of that row of table.
They will be used to set the same attributes for
all the ports in the system.
Note: prior setting this object, all the intended
attributes of the given row of the table must be set.
Otherwise, the current data of the row will be used to
set the entire port-table. The previous setting will
be overwritten by the new one."
::= { snSwInfo 8 }
snFdbTableCurEntry OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current total entry number of FDB are configured."
::= { snSwInfo 9 }
snFdbTableStationFlush OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
error(2),
flush(3),
flushing(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The following values of the flush state
can only be read:
normal(1)... normal state
error(2)... operation failed
flushing(4)... in process
The following value can be written:
flush(3).....do flush
The agent will return a response even before the flush is done.
And the read value will be flushing until flush is done.
And the flush request will be rejected until error or normal."
::= { snSwInfo 10 }
snPortStpSetAll OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of this object is 1 which means invoking
Port STP Set-all command. The snPortStpPriority,
snPortStpPathCost, the read-write STP related
attributes of the first row of table will be used
to set the same attributes for all the ports in the
system.
Note: prior setting this object, all the intended
attributes of the given row of the table must be set.
Otherwise, the current data of the row will be used to
set the entire port-table. The previous setting will
be overwritten by the new one."
::= { snSwInfo 11 }
snSwProbePortNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A chassis switch probe port is operated as a traffic analyzer
port and only one port can be assigned in the chassis.
The bit 0 to bit 7: port number.
The bit 8 to bit 11: slot number.
A stackable switch is only assigned with one probe port as a
traffic analyzer."
::= { snSwInfo 12 }
snSw8021qTagMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Switch Group is configured with the IEEE802.1q
Tagging mode either enabled or disabled and the
default is disabled mode.
enabled(1)...........activate IEEE802.1q Tagging mode.
disabled(0)..........no IEEE802.1q Tagging."
::= { snSwInfo 13 }
snSwGlobalStpMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Spanning Tree System Global Mode in the Switch Group
can be set either enabled or disabled and the default is
enabled mode.
enabled(1)...........activate Spanning Tree
disabled(0)..........no Spanning Tree"
::= { snSwInfo 14 }
snSwIpMcastQuerierMode OBJECT-TYPE
SYNTAX INTEGER {
querier(1),
nonQuerier(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP Multicast pruning mode is configured either
Non-Querier or Querier mode and the default is
querier mode.
querier(1)...........when prunning traffic locally
within the VLAN.
nonQuerier(2)........when running with a multicast
capable router in the network."
::= { snSwInfo 15 }
snSwViolatorPortNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port number of the switch or router that received
a violator packet. It is included in the locked
address violation trap.
The bit 0 to bit 7: port number.
The bit 8 to bit 11: slot number (slot for chassis only)."
::= { snSwInfo 17 }
snSwViolatorMacAddress OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source address of the violator packet received
by the switch or router. It is included in the locked
address violation trap."
::= { snSwInfo 18 }
snVLanGroupVlanMaxEntry OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The maximum number of VLAN entries are allowed to configure."
::= { snSwInfo 19 }
snSwEosBufferSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A specific buffer size for all the different EOS buffers."
::= { snSwInfo 20 }
snVLanByPortEntrySize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size of each VLAN table entry."
::= { snSwInfo 21 }
snSwPortEntrySize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size of each port table entry."
::= { snSwInfo 22 }
snFdbStationEntrySize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size of each Fdb station table entry."
::= { snSwInfo 23 }
snPortStpEntrySize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size of each port stp table entry."
::= { snSwInfo 24 }
snSwEnableBridgeNewRootTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the SNMP agent process is
permitted to generate bridge new root traps."
DEFVAL { enabled }
::= { snSwInfo 25 }
snSwEnableBridgeTopoChangeTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the SNMP agent process is
permitted to generate bridge topology change
traps."
DEFVAL { enabled }
::= { snSwInfo 26 }
snSwEnableLockedAddrViolationTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the SNMP agent process is
permitted to generate locked address violation
traps."
DEFVAL { enabled }
::= { snSwInfo 27 }
snSwIpxL3SwMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Switch Group is configured with the Layer3
IPX Switch mode either enabled or disabled and
the default is disabled mode.
enabled(1)...........activate Layer3 Switch
disabled(0)..........disable Layer3 Switch"
::= { snSwInfo 28 }
snVLanByIpSubnetMaxSubnets OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of subnets for each IP VLAN."
::= { snSwInfo 29 }
snVLanByIpxNetMaxNetworks OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of networks for each IPX VLAN."
::= { snSwInfo 30 }
snSwProtocolVLanMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"disabled(0) - represents system with Protocol VLAN disabled.
enabled(1) - represents system with Protocol VLAN enabled (Layer3 VLAN)."
::= { snSwInfo 31 }
snMacStationVLanId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This MAC Station VLAN ID index to the standard Forwarding Database for Transparent Bridge Table.
(dot1dTpFdbTable). Since the dot1dTpFdbTable index is the MAC Address assigned to one of
the ports in the bridge(VLAN) and each MAC address can be re-assigned to a different
ports belonging to different bridges(VLANs), the snMacStationVLanId can be used by
users to specify which bridge(VLAN) MAC Station information of the dot1dTpFdbTable
users want to retrieve. If users do not specify the VLan ID in this MIB, the default
VLAN (bridge) ID will be used when dot1dTpFdbTable is retrieved."
::= { snSwInfo 32 }
snSwClearCounters OBJECT-TYPE
SYNTAX INTEGER {
valid(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"valid(0) - a SNMP-GET of this mib shows that it is valid command to use.
clear(1) - represents clear counter command of the following counters:
Dot3, MIB2, IP and IPX counters for all ports."
::= { snSwInfo 33 }
snSw8021qTagType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IEEE802.1q tag type embedded in the length/type field of
an Ethernet packet. It specifies that the 2 octets after the
length/type field in an Ethernet packet is the tag value."
DEFVAL { 33024 }
::= { snSwInfo 34 }
snSwBroadcastLimit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Limit the number of broadcast packets to forward out of the
switch ports. This object specifies the number of broadcast
packets per second. Setting a value of 0 to this object
disables the limitation check."
DEFVAL { 0 }
::= { snSwInfo 35 }
snSwMaxMacFilterPerSystem OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of MAC Filters per system in the MAC Filter table."
::= { snSwInfo 36 }
snSwMaxMacFilterPerPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of MAC Filters per port in the Port MAC Access Filter table."
::= { snSwInfo 37 }
snSwDefaultVLanId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The VLAN ID of the DEFAULT PORT-VLAN."
::= { snSwInfo 38 }
snSwGlobalAutoNegotiate OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1),
negFullAuto(2),
other(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This feature only applies to Gigabit Ethernet ports. If set
to disable(0), all Gigabit Ethernet ports will be put to non-
negotiation mode. If set to enable(1), all Gigabit Ethernet
ports will start auto-negotiation indefinitely until succeed.
If set to negFullAuto(2), all Gigabit Ethernet ports will start
with auto-negotiation, if the negotiation failed, then they
will automatically switch to non-negotiation mode. Stackable
products (except TurboIron 8) Gigabit Ethernet ports do not
support negFullAuto(2). If the snSwPortInfoAutoNegotiate value
of a port was not set to global, this global value does not
apply to the negotiation mode of that port."
DEFVAL { negFullAuto }
::= { snSwInfo 39 }
snSwQosMechanism OBJECT-TYPE
SYNTAX INTEGER { strict(0), weighted(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the qos mechanism is
strict or weighted."
DEFVAL { weighted }
::= { snSwInfo 40 }
snSwSingleStpMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Single Spanning Tree System Mode in the Switch Group
can be set either enabled or disabled and the default is
disabled mode.
enabled(1)...........activate Single Spanning Tree
disabled(0)..........no Single Spanning Tree"
::= { snSwInfo 41 }
snSwFastStpMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Fast Spanning Tree System Mode in the Switch Group
can be set either enabled or disabled and the default is
enabled mode.
enabled(1)...........activate Fast Spanning Tree
disabled(0)..........no Fast Spanning Tree"
::= { snSwInfo 42 }
-- VLAN Layer 2 Switch VLAN By Port Information Table
snVLanByPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnVLanByPortEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"If snSwGroupOperMode is configured as basic mode
which is VLAN by Port, Layer2 switching,
then this table is valid. Each VLAN switch port
could have a number of VLAN IDs."
::= { snVLanInfo 1 }
snVLanByPortEntry OBJECT-TYPE
SYNTAX SnVLanByPortEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An entry in the VLAN By Port Information table.
snVLanByPortVLanIndex = 1 and with
snVLanByPortVLanId = 1 together implies all attributes
applying to the Global switch group i.e. noVLan.
A SNMP SET PDU for a row of the snVLanByPortTable
requires the entired sequence of the MIB Objects in each
snVLanByPortEntry stored in one PDU. Otherwise,
GENERR return-value will be returned."
INDEX {
snVLanByPortVLanIndex
}
::= { snVLanByPortTable 1 }
SnVLanByPortEntry ::= SEQUENCE {
snVLanByPortVLanIndex
INTEGER,
snVLanByPortVLanId
INTEGER,
snVLanByPortPortMask
PortMask,
snVLanByPortQos
INTEGER,
snVLanByPortStpMode
INTEGER,
snVLanByPortStpPriority
INTEGER,
snVLanByPortStpGroupMaxAge
INTEGER,
snVLanByPortStpGroupHelloTime
INTEGER,
snVLanByPortStpGroupForwardDelay
INTEGER,
snVLanByPortRowStatus
INTEGER,
snVLanByPortOperState
INTEGER,
snVLanByPortBaseNumPorts
INTEGER,
snVLanByPortBaseType
INTEGER,
snVLanByPortStpProtocolSpecification
INTEGER,
snVLanByPortStpMaxAge
Timeout,
snVLanByPortStpHelloTime
Timeout,
snVLanByPortStpHoldTime
INTEGER,
snVLanByPortStpForwardDelay
Timeout,
snVLanByPortStpTimeSinceTopologyChange
TimeTicks,
snVLanByPortStpTopChanges
Counter,
snVLanByPortStpRootCost
INTEGER,
snVLanByPortStpRootPort
INTEGER,
snVLanByPortStpDesignatedRoot
BridgeId,
snVLanByPortBaseBridgeAddress
MacAddress,
snVLanByPortVLanName
DisplayString,
snVLanByPortRouterIntf
INTEGER,
snVLanByPortChassisPortMask
OCTET STRING,
snVLanByPortPortList
OCTET STRING
}
snVLanByPortVLanIndex OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The VLAN ID index must not be greater than the
snVLanGroupVlanMaxEntry. Each VLAN Identifier can
have a membership of multiple ports."
::= { snVLanByPortEntry 1 }
snVLanByPortVLanId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The VLAN ID index to the VLAN By Port Info Table.
Each VLAN Identifier can have a membership of multiple
ports."
::= { snVLanByPortEntry 2 }
snVLanByPortPortMask OBJECT-TYPE
SYNTAX PortMask
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Standand-alone switch VLAN port membership. (It was obsoleted for Chassis Product)"
::= { snVLanByPortEntry 3 }
snVLanByPortQos OBJECT-TYPE
SYNTAX INTEGER {
level0(0),
level1(1),
level2(2),
level3(3),
level4(4),
level5(5),
level6(6),
level7(7)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Stand alone stackable switch VLAN Priority values are:
low(0) -- low prority
high(1) -- high prority.
The BigIron switch VLAN Priority values are:
level0(0), level1(1), level2(2), level3(3),
level4(4), level5(5), level6(6), level7(7) "
::= { snVLanByPortEntry 4 }
snVLanByPortStpMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Spanning Tree Mode in the Switch Group can be set
either enabled or disabled and the default is
enabled mode.
enabled(1)...........activate Spanning Tree
disabled(0)..........no Spanning Tree"
::= { snVLanByPortEntry 5 }
snVLanByPortStpPriority OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"dot1dStpPriority : The value of the write-able
portion of the Stp ID, i.e., the first two octets
of the (8 octet long) Bridge ID. The other (last) 6
octets of the Bridge ID are given by the value of the
base bridge address - dot1dBaseBridgeAddress."
::= { snVLanByPortEntry 6 }
snVLanByPortStpGroupMaxAge OBJECT-TYPE
SYNTAX INTEGER (6..40)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"dot1dStpBridgeMaxAge: From RFC1493(Bridge MIB).
The value that all bridges use for MaxAge when
this bridge is acting as the root.
Note that 802.1D-1990 specifies that the
range for this parameter is related to the value of
dot1dStpBridgeHelloTime. The granularity of this
timer is specified by 802.1D-1990 to be 1 second.
An agent may return a badValue error if a set is
attempted to a value which is not a whole number
of seconds."
::= { snVLanByPortEntry 7 }
snVLanByPortStpGroupHelloTime OBJECT-TYPE
SYNTAX INTEGER (1..10)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"dot1dStpBridgeHelloTime: From RFC1493(Bridge MIB).
The value that all bridges use for HelloTime when
this bridge is acting as the root. The
granularity of this timer is specified by 802.1D-
1990 to be 1 second. An agent may return a
badValue error if a set is attempted to a value
which is not a whole number of seconds."
::= { snVLanByPortEntry 8 }
snVLanByPortStpGroupForwardDelay OBJECT-TYPE
SYNTAX INTEGER (2..30)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"dot1dStpBridgeForwardDelay : From RFC1493(Bridge MIB).
The value that all bridges use for ForwardDelay
when this bridge is acting as the root. Note that
802.1D-1990 specifies that the range for this
parameter is related to the value of
dot1dStpBridgeMaxAge. The granularity of this
timer is specified by 802.1D-1990 to be 1 second.
An agent may return a badValue error if a set is
attempted to a value which is not a whole number
of seconds."
::= { snVLanByPortEntry 9 }
snVLanByPortRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4),
modify(5)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object is used to create and
delete row in the table and control
if they are used. The values
that can be written are:
delete(3)...deletes the row
create(4)...creates a new row
modify(5)...modifies an exsisting row
If the row exists, then a SET with
value of create(4) returns error
'badValue'. Deleted rows go away
immediately. The following values
can be returned on reads:
noSuch(0)...no such row
other(1)....some other case
valid(2)....the row exists and is valid"
::= { snVLanByPortEntry 10 }
snVLanByPortOperState OBJECT-TYPE
SYNTAX INTEGER {
notActivated(0),
activated(1)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"By default, this mode is set to notActivated(0).
notActivated(0)...the VLAN entry is not activated and not in running mode.
activated(1)......the VLAN entry is activated and in running mode"
::= { snVLanByPortEntry 11 }
snVLanByPortBaseNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of ports controlled by this bridging
entity."
::= { snVLanByPortEntry 12 }
snVLanByPortBaseType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
transparent-only(2),
sourceroute-only(3),
srt(4)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Indicates what type of bridging this bridge can
perform. If a bridge is actually performing a
certain type of bridging this will be indicated by
entries in the port table for the given type."
::= { snVLanByPortEntry 13 }
snVLanByPortStpProtocolSpecification OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
decLb100(2),
ieee8021d(3)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"An indication of what version of the Spanning
Tree Protocol is being run. The value
'decLb100(2)' indicates the DEC LANbridge 100
Spanning Tree protocol. IEEE 802.1d
implementations will return 'ieee8021d(3)'. If
future versions of the IEEE Spanning Tree Protocol
are released that are incompatible with the
current version a new value will be defined."
::= { snVLanByPortEntry 14 }
snVLanByPortStpMaxAge OBJECT-TYPE
SYNTAX Timeout
ACCESS read-only
STATUS deprecated
DESCRIPTION
"dot1dStpMaxAge: From RFC1493(Bridge MIB).
The maximum age of Spanning Tree Protocol
information learned from the network on any port
before it is discarded, in units of hundredths of
a second. This is the actual value that this
bridge is currently using."
::= { snVLanByPortEntry 15 }
snVLanByPortStpHelloTime OBJECT-TYPE
SYNTAX Timeout
ACCESS read-only
STATUS deprecated
DESCRIPTION
"dot1dStpHelloTime: From RFC1493(Bridge MIB).
The amount of time between the transmission of
Configuration bridge PDUs by this node on any port
when it is the root of the spanning tree or trying
to become so, in units of hundredths of a second.
This is the actual value that this bridge is
currently using."
::= { snVLanByPortEntry 16 }
snVLanByPortStpHoldTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"dot1dStpHoldTime: From RFC1493(Bridge MIB).
This time value determines the interval length
during which no more than two Configuration bridge
PDUs shall be transmitted by this node, in units
of hundredths of a second."
::= { snVLanByPortEntry 17 }
snVLanByPortStpForwardDelay OBJECT-TYPE
SYNTAX Timeout
ACCESS read-only
STATUS deprecated
DESCRIPTION
"dot1dStpForwardDelay: From RFC1493(Bridge MIB).
This time value, measured in units of hundredths
of a second, controls how fast a port changes its
spanning state when moving towards the Forwarding
state. The value determines how long the port
stays in each of the Listening and Learning
states, which precede the Forwarding state. This
value is also used, when a topology change has
been detected and is underway, to age all dynamic
entries in the Forwarding Database. [Note that
this value is the one that this bridge is
currently using, in contrast to
dot1dStpBridgeForwardDelay which is the value that
this bridge and all others would start using
if/when this bridge were to become the root.]"
::= { snVLanByPortEntry 18 }
snVLanByPortStpTimeSinceTopologyChange OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The time (in hundredths of a second) since the
last time a topology change was detected by the
bridge entity."
::= { snVLanByPortEntry 19 }
snVLanByPortStpTopChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The total number of topology changes detected by
this bridge since the management entity was last
reset or initialized."
::= { snVLanByPortEntry 20 }
snVLanByPortStpRootCost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"dot1dStpRootCost: From RFC1493(Bridge MIB).
The cost of the path to the root as seen from
this bridge."
::= { snVLanByPortEntry 21 }
snVLanByPortStpRootPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"dot1dStpRootPort: From RFC1493(Bridge MIB).
The port number of the port which offers the
lowest cost path from this bridge to the root
bridge."
::= { snVLanByPortEntry 22 }
snVLanByPortStpDesignatedRoot OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS deprecated
DESCRIPTION
"dot1dStpDesignatedRoot: From RFC1493(Bridge MIB).
The bridge identifier of the root of the spanning
tree as determined by the Spanning Tree Protocol
as executed by this node. This value is used as
the Root Identifier parameter in all Configuration
Bridge PDUs originated by this node."
::= { snVLanByPortEntry 23 }
snVLanByPortBaseBridgeAddress OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The MAC address used by this bridge when it must
be referred to in a unique fashion. It is
recommended that this be the numerically smallest
MAC address of all ports that belong to this
bridge. However it is only required to be unique.
When concatenated with dot1dStpPriority a unique
BridgeIdentifier is formed which is used in the
Spanning Tree Protocol."
::= { snVLanByPortEntry 24 }
snVLanByPortVLanName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"VLAN Community Name string."
::= { snVLanByPortEntry 25 }
snVLanByPortRouterIntf OBJECT-TYPE
SYNTAX INTEGER (1..60)
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Optional: A virtual interface for router to the VLAN -- applied to router only.
If a SNMP-Get value is zero, that means this object was not configured."
::= { snVLanByPortEntry 26 }
snVLanByPortChassisPortMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(32))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Chassis VLAN switch port membership.
(It was obsoleted after release 07100, replaced by snVLanByPortPortList)"
::= { snVLanByPortEntry 27 }
snVLanByPortPortList OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS deprecated
DESCRIPTION
"A list of port indices which are the port
membership of a VLAN By Port. Each port index is a
16-bit integer in big endian order. 8-bit is the slot number,
the other 8-bit is the port number."
::= { snVLanByPortEntry 28 }
-- Port VLAN (Layer 2 VLAN) Port Membership Table
-- Use this table to create or delete a VLAN entry
snVLanByPortMemberTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnVLanByPortMemberEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Port VLAN (Layer 2 VLAN) port membership table."
::= { snVLanInfo 6 }
snVLanByPortMemberEntry OBJECT-TYPE
SYNTAX SnVLanByPortMemberEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of the port VLAN membership table."
INDEX { snVLanByPortMemberVLanId, snVLanByPortMemberPortId }
::= { snVLanByPortMemberTable 1 }
SnVLanByPortMemberEntry ::= SEQUENCE {
snVLanByPortMemberVLanId
INTEGER,
snVLanByPortMemberPortId
INTEGER,
snVLanByPortMemberRowStatus
INTEGER
}
snVLanByPortMemberVLanId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The VLAN identifier (VLAN ID)."
::= { snVLanByPortMemberEntry 1 }
snVLanByPortMemberPortId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ifIndex which is a member of the port VLAN."
::= { snVLanByPortMemberEntry 2 }
snVLanByPortMemberRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to create and
delete row in the table and control
if they are used. The values
that can be written are:
delete(3)...deletes the row
create(4)...creates a new row
If the row exists, then a SET with
value of create(4) returns error
'badValue'. Deleted rows go away
immediately. The following values
can be returned on reads:
noSuch(0)...no such row
other(1)....some other case
valid(2)....the row exists and is valid"
::= { snVLanByPortMemberEntry 3 }
-- Port VLAN (Layer 2 VLAN) Configuration Table
-- Use this table to configure a VLAN entry
snVLanByPortCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnVLanByPortCfgEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Port VLAN (Layer 2 VLAN) configuration table."
::= { snVLanInfo 7 }
snVLanByPortCfgEntry OBJECT-TYPE
SYNTAX SnVLanByPortCfgEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of the port VLAN configuration table."
INDEX { snVLanByPortCfgVLanId }
::= { snVLanByPortCfgTable 1 }
SnVLanByPortCfgEntry ::= SEQUENCE {
snVLanByPortCfgVLanId
INTEGER,
snVLanByPortCfgQos
INTEGER,
snVLanByPortCfgStpMode
INTEGER,
snVLanByPortCfgStpPriority
INTEGER,
snVLanByPortCfgStpGroupMaxAge
INTEGER,
snVLanByPortCfgStpGroupHelloTime
INTEGER,
snVLanByPortCfgStpGroupForwardDelay
INTEGER,
snVLanByPortCfgBaseNumPorts
INTEGER,
snVLanByPortCfgBaseType
INTEGER,
snVLanByPortCfgStpProtocolSpecification
INTEGER,
snVLanByPortCfgStpMaxAge
Timeout,
snVLanByPortCfgStpHelloTime
Timeout,
snVLanByPortCfgStpHoldTime
INTEGER,
snVLanByPortCfgStpForwardDelay
Timeout,
snVLanByPortCfgStpTimeSinceTopologyChange
TimeTicks,
snVLanByPortCfgStpTopChanges
Counter,
snVLanByPortCfgStpRootCost
INTEGER,
snVLanByPortCfgStpRootPort
INTEGER,
snVLanByPortCfgStpDesignatedRoot
BridgeId,
snVLanByPortCfgBaseBridgeAddress
MacAddress,
snVLanByPortCfgVLanName
DisplayString,
snVLanByPortCfgRouterIntf
INTEGER,
snVLanByPortCfgRowStatus
INTEGER
}
snVLanByPortCfgVLanId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The VLAN identifier (VLAN ID)."
::= { snVLanByPortCfgEntry 1 }
snVLanByPortCfgQos OBJECT-TYPE
SYNTAX INTEGER {
level0(0),
level1(1),
level2(2),
level3(3),
level4(4),
level5(5),
level6(6),
level7(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Stand alone stackable switch VLAN Priority values are:
level0(0) -- low prority
level1(1) -- high prority.
The BigIron switch VLAN Priority values are:
level0(0), level1(1), level2(2), level3(3),
level4(4), level5(5), level6(6), level7(7) "
::= { snVLanByPortCfgEntry 2 }
snVLanByPortCfgStpMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Spanning Tree Mode in the Switch Group can be set
either enabled or disabled and the default is
enabled mode.
enabled(1)...........activate Spanning Tree
disabled(0)..........no Spanning Tree"
::= { snVLanByPortCfgEntry 3 }
snVLanByPortCfgStpPriority OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"dot1dStpPriority : The value of the write-able
portion of the Stp ID, i.e., the first two octets
of the (8 octet long) Bridge ID. The other (last) 6
octets of the Bridge ID are given by the value of the
base bridge address - dot1dBaseBridgeAddress."
::= { snVLanByPortCfgEntry 4 }
snVLanByPortCfgStpGroupMaxAge OBJECT-TYPE
SYNTAX INTEGER (6..40)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"dot1dStpBridgeMaxAge: From RFC1493(Bridge MIB).
The value that all bridges use for MaxAge when
this bridge is acting as the root.
Note that 802.1D-1990 specifies that the
range for this parameter is related to the value of
dot1dStpBridgeHelloTime. The granularity of this
timer is specified by 802.1D-1990 to be 1 second.
An agent may return a badValue error if a set is
attempted to a value which is not a whole number
of seconds."
::= { snVLanByPortCfgEntry 5 }
snVLanByPortCfgStpGroupHelloTime OBJECT-TYPE
SYNTAX INTEGER (1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"dot1dStpBridgeHelloTime: From RFC1493(Bridge MIB).
The value that all bridges use for HelloTime when
this bridge is acting as the root. The
granularity of this timer is specified by 802.1D-
1990 to be 1 second. An agent may return a
badValue error if a set is attempted to a value
which is not a whole number of seconds."
::= { snVLanByPortCfgEntry 6 }
snVLanByPortCfgStpGroupForwardDelay OBJECT-TYPE
SYNTAX INTEGER (2..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"dot1dStpBridgeForwardDelay : From RFC1493(Bridge MIB).
The value that all bridges use for ForwardDelay
when this bridge is acting as the root. Note that
802.1D-1990 specifies that the range for this
parameter is related to the value of
dot1dStpBridgeMaxAge. The granularity of this
timer is specified by 802.1D-1990 to be 1 second.
An agent may return a badValue error if a set is
attempted to a value which is not a whole number
of seconds."
::= { snVLanByPortCfgEntry 7 }
snVLanByPortCfgBaseNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of ports controlled by this bridging
entity."
::= { snVLanByPortCfgEntry 8 }
snVLanByPortCfgBaseType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
transparent-only(2),
sourceroute-only(3),
srt(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates what type of bridging this bridge can
perform. If a bridge is actually performing a
certain type of bridging this will be indicated by
entries in the port table for the given type."
::= { snVLanByPortCfgEntry 9 }
snVLanByPortCfgStpProtocolSpecification OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
decLb100(2),
ieee8021d(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An indication of what version of the Spanning
Tree Protocol is being run. The value
'decLb100(2)' indicates the DEC LANbridge 100
Spanning Tree protocol. IEEE 802.1d
implementations will return 'ieee8021d(3)'. If
future versions of the IEEE Spanning Tree Protocol
are released that are incompatible with the
current version a new value will be defined."
::= { snVLanByPortCfgEntry 10 }
snVLanByPortCfgStpMaxAge OBJECT-TYPE
SYNTAX Timeout
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dot1dStpMaxAge: From RFC1493(Bridge MIB).
The maximum age of Spanning Tree Protocol
information learned from the network on any port
before it is discarded, in units of hundredths of
a second. This is the actual value that this
bridge is currently using."
::= { snVLanByPortCfgEntry 11 }
snVLanByPortCfgStpHelloTime OBJECT-TYPE
SYNTAX Timeout
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dot1dStpHelloTime: From RFC1493(Bridge MIB).
The amount of time between the transmission of
Configuration bridge PDUs by this node on any port
when it is the root of the spanning tree or trying
to become so, in units of hundredths of a second.
This is the actual value that this bridge is
currently using."
::= { snVLanByPortCfgEntry 12 }
snVLanByPortCfgStpHoldTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dot1dStpHoldTime: From RFC1493(Bridge MIB).
This time value determines the interval length
during which no more than two Configuration bridge
PDUs shall be transmitted by this node, in units
of hundredths of a second."
::= { snVLanByPortCfgEntry 13 }
snVLanByPortCfgStpForwardDelay OBJECT-TYPE
SYNTAX Timeout
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dot1dStpForwardDelay: From RFC1493(Bridge MIB).
This time value, measured in units of hundredths
of a second, controls how fast a port changes its
spanning state when moving towards the Forwarding
state. The value determines how long the port
stays in each of the Listening and Learning
states, which precede the Forwarding state. This
value is also used, when a topology change has
been detected and is underway, to age all dynamic
entries in the Forwarding Database. [Note that
this value is the one that this bridge is
currently using, in contrast to
dot1dStpBridgeForwardDelay which is the value that
this bridge and all others would start using
if/when this bridge were to become the root.]"
::= { snVLanByPortCfgEntry 14 }
snVLanByPortCfgStpTimeSinceTopologyChange OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time (in hundredths of a second) since the
last time a topology change was detected by the
bridge entity."
::= { snVLanByPortCfgEntry 15 }
snVLanByPortCfgStpTopChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of topology changes detected by
this bridge since the management entity was last
reset or initialized."
::= { snVLanByPortCfgEntry 16 }
snVLanByPortCfgStpRootCost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dot1dStpRootCost: From RFC1493(Bridge MIB).
The cost of the path to the root as seen from
this bridge."
::= { snVLanByPortCfgEntry 17 }
snVLanByPortCfgStpRootPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dot1dStpRootPort: From RFC1493(Bridge MIB).
The port number of the port which offers the
lowest cost path from this bridge to the root
bridge."
::= { snVLanByPortCfgEntry 18 }
snVLanByPortCfgStpDesignatedRoot OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dot1dStpDesignatedRoot: From RFC1493(Bridge MIB).
The bridge identifier of the root of the spanning
tree as determined by the Spanning Tree Protocol
as executed by this node. This value is used as
the Root Identifier parameter in all Configuration
Bridge PDUs originated by this node."
::= { snVLanByPortCfgEntry 19 }
snVLanByPortCfgBaseBridgeAddress OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address used by this bridge when it must
be referred to in a unique fashion. It is
recommended that this be the numerically smallest
MAC address of all ports that belong to this
bridge. However it is only required to be unique.
When concatenated with dot1dStpPriority a unique
BridgeIdentifier is formed which is used in the
Spanning Tree Protocol."
::= { snVLanByPortCfgEntry 20 }
snVLanByPortCfgVLanName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VLAN Community Name string."
::= { snVLanByPortCfgEntry 21 }
snVLanByPortCfgRouterIntf OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Optional: A virtual interface for router to the VLAN -- applied to router only.
If a SNMP-Get value is zero, that means this object was not configured."
::= { snVLanByPortCfgEntry 22 }
snVLanByPortCfgRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Use object to delete a vlan entry."
::= { snVLanByPortCfgEntry 23 }
-- VLAN by Protocol Configuration Table
snVLanByProtocolTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnVLanByProtocolEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"."
::= { snVLanInfo 2 }
snVLanByProtocolEntry OBJECT-TYPE
SYNTAX SnVLanByProtocolEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the VLAN By Protocol Configuration table. "
INDEX {
snVLanByProtocolVLanId,
snVLanByProtocolIndex
}
::= { snVLanByProtocolTable 1 }
SnVLanByProtocolEntry ::= SEQUENCE {
snVLanByProtocolVLanId
INTEGER,
snVLanByProtocolIndex
INTEGER,
snVLanByProtocolDynamic
INTEGER,
snVLanByProtocolStaticMask
PortMask,
snVLanByProtocolExcludeMask
PortMask,
snVLanByProtocolRouterIntf
INTEGER,
snVLanByProtocolRowStatus
INTEGER,
snVLanByProtocolDynamicMask
PortMask,
snVLanByProtocolChassisStaticMask
OCTET STRING,
snVLanByProtocolChassisExcludeMask
OCTET STRING,
snVLanByProtocolChassisDynamicMask
OCTET STRING,
snVLanByProtocolVLanName
DisplayString,
snVLanByProtocolStaticPortList
OCTET STRING,
snVLanByProtocolExcludePortList
OCTET STRING,
snVLanByProtocolDynamicPortList
OCTET STRING
}
snVLanByProtocolVLanId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The VLAN ID index to both of the VLAN By Port Info Table
and this table."
::= { snVLanByProtocolEntry 1 }
snVLanByProtocolIndex OBJECT-TYPE
SYNTAX INTEGER {
ip(1),
ipx(2),
appleTalk(3),
decNet(4),
netBios(5),
others(6),
ipv6(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The following IP/IPX protocol VLAN types are operated
in Layer3 VLAN such as : ip(1), ipx(2), ipv6(7)
The following are operated in Layer2 bridging such as:
appleTalk(3), decNet(4), netBios(5),
others(6) -- other protocols which are defined here. "
::= { snVLanByProtocolEntry 2 }
snVLanByProtocolDynamic OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" disabled(0) : disabled dynamic port inclusion - applied to switch only.
enabled(1) : enabled dynamic port inclusion - applied to switch only. "
::= { snVLanByProtocolEntry 3 }
snVLanByProtocolStaticMask OBJECT-TYPE
SYNTAX PortMask
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Standand-alone switch Protocol VLAN port membership applied in static mode.
(It was obsoleted for Chassis Product)"
::= { snVLanByProtocolEntry 4 }
snVLanByProtocolExcludeMask OBJECT-TYPE
SYNTAX PortMask
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Standand-alone switch Protocol VLAN port membership applied in exclusive mode.
(It was obsoleted for Chassis Product)"
::= { snVLanByProtocolEntry 5 }
snVLanByProtocolRouterIntf OBJECT-TYPE
SYNTAX INTEGER (1..60)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Optional: A virtual interface for router to the VLAN -- applied to router only.
If a SNMP-Get value is zero, that means this object was not configured."
::= { snVLanByProtocolEntry 6 }
snVLanByProtocolRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4),
modify(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to create and
delete row in the table and control
if they are used. The values
that can be written are:
delete(3)...deletes the row
create(4)...creates a new row
modify(5)...modifies an exsisting row
If the row exists, then a SET with
value of create(4) returns error
'badValue'. Deleted rows go away
immediately. The following values
can be returned on reads:
noSuch(0)...no such row
other(1)....some other case
valid(2)....the row exists and is valid"
::= { snVLanByProtocolEntry 7 }
snVLanByProtocolDynamicMask OBJECT-TYPE
SYNTAX PortMask
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The Standand-alone switch Protocol VLAN active port membership.
(It was obsoleted for Chassis Product)"
::= { snVLanByProtocolEntry 8 }
snVLanByProtocolChassisStaticMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(32))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Chassis Protocol VLAN port membership applied in static mode.
(It was obsoleted after release 07100, replaced by snVLanByProtocolStaticPortList)"
::= { snVLanByProtocolEntry 9 }
snVLanByProtocolChassisExcludeMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(32))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Chassis Protocol VLAN port membership applied in exclusive mode.
(It was obsoleted after release 07100, replaced by snVLanByProtocolExcludePortList)"
::= { snVLanByProtocolEntry 10 }
snVLanByProtocolChassisDynamicMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(32))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The Chassis Protocol VLAN active port membership.
(It was obsoleted after release 07100, replaced by snVLanByProtocolDynamicPortList)"
::= { snVLanByProtocolEntry 11 }
snVLanByProtocolVLanName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VLAN Community Name string."
::= { snVLanByProtocolEntry 12 }
snVLanByProtocolStaticPortList OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A list of port indices which are the configured port
membership of the Protocol VLAN. Each port index is a
16-bit integer in big endian order. 8-bit is the slot number,
the other 8-bit is the port number."
::= { snVLanByProtocolEntry 13 }
snVLanByProtocolExcludePortList OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A list of port indices which are the excluded from port
membership of the Protocol VLAN. Each port index is a
16-bit integer in big endian order. 8-bit is the slot number,
the other 8-bit is the port number."
::= { snVLanByProtocolEntry 14 }
snVLanByProtocolDynamicPortList OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A list of port indices which are dynamically joining the port
membership of the Protocol VLAN. Each port index is a
16-bit integer in big endian order. 8-bit is the slot number,
the other 8-bit is the port number."
::= { snVLanByProtocolEntry 15 }
-- VLAN By IP Subnet Configuration Table
snVLanByIpSubnetTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnVLanByIpSubnetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of the VLAN By IPX Network Number Table."
::= { snVLanInfo 3 }
snVLanByIpSubnetEntry OBJECT-TYPE
SYNTAX SnVLanByIpSubnetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the VLAN By IP Subnet Configuration table. "
INDEX {
snVLanByIpSubnetVLanId,
snVLanByIpSubnetIpAddress,
snVLanByIpSubnetSubnetMask
}
::= { snVLanByIpSubnetTable 1 }
SnVLanByIpSubnetEntry ::= SEQUENCE {
snVLanByIpSubnetVLanId
INTEGER,
snVLanByIpSubnetIpAddress
IpAddress,
snVLanByIpSubnetSubnetMask
IpAddress,
snVLanByIpSubnetDynamic
INTEGER,
snVLanByIpSubnetStaticMask
PortMask,
snVLanByIpSubnetExcludeMask
PortMask,
snVLanByIpSubnetRouterIntf
INTEGER,
snVLanByIpSubnetRowStatus
INTEGER,
snVLanByIpSubnetDynamicMask
PortMask,
snVLanByIpSubnetChassisStaticMask
OCTET STRING,
snVLanByIpSubnetChassisExcludeMask
OCTET STRING,
snVLanByIpSubnetChassisDynamicMask
OCTET STRING,
snVLanByIpSubnetVLanName
DisplayString,
snVLanByIpSubnetStaticPortList
OCTET STRING,
snVLanByIpSubnetExcludePortList
OCTET STRING,
snVLanByIpSubnetDynamicPortList
OCTET STRING
}
snVLanByIpSubnetVLanId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The VLAN ID index to both of the VLAN By Port Info Table
and this table."
::= { snVLanByIpSubnetEntry 1 }
snVLanByIpSubnetIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Subnet IP address."
::= { snVLanByIpSubnetEntry 2 }
snVLanByIpSubnetSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Subnet mask associated with the Subnet IP address."
::= { snVLanByIpSubnetEntry 3 }
snVLanByIpSubnetDynamic OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" disabled(0) : disabled dynamic port inclusion - applied to switch only.
enabled(1) : enabled dynamic port inclusion - applied to switch only. "
::= { snVLanByIpSubnetEntry 4 }
snVLanByIpSubnetStaticMask OBJECT-TYPE
SYNTAX PortMask
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Standand-alone switch VLAN By Subnet port membership applied in static mode.
(It was obsoleted for Chassis Product)"
::= { snVLanByIpSubnetEntry 5 }
snVLanByIpSubnetExcludeMask OBJECT-TYPE
SYNTAX PortMask
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Standand-alone switch VLAN By Subnet port membership applied in exclusive mode.
(It was obsoleted for Chassis Product)"
::= { snVLanByIpSubnetEntry 6 }
snVLanByIpSubnetRouterIntf OBJECT-TYPE
SYNTAX INTEGER (1..60)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Optional: A virtual interface for router to the VLAN -- applied to router only.
If a SNMP-Get value is zero, that means this object was not configured."
::= { snVLanByIpSubnetEntry 7 }
snVLanByIpSubnetRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4),
modify(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to create and
delete row in the table and control
if they are used. The values
that can be written are:
delete(3)...deletes the row
create(4)...creates a new row
modify(5)...modifies an exsisting row
If the row exists, then a SET with
value of create(4) returns error
'badValue'. Deleted rows go away
immediately. The following values
can be returned on reads:
noSuch(0)...no such row
other(1)....some other case
valid(2)....the row exists and is valid"
::= { snVLanByIpSubnetEntry 8 }
snVLanByIpSubnetDynamicMask OBJECT-TYPE
SYNTAX PortMask
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The Standand-alone switch VLAN By Subnet active port membership.
(It was obsoleted for Chassis Product)"
::= { snVLanByIpSubnetEntry 9 }
snVLanByIpSubnetChassisStaticMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(32))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Chassis VLAN By Subnet port membership applied in static mode.
(It was obsoleted after release 07100, replaced by snVLanByIpSubnetStaticPortList)"
::= { snVLanByIpSubnetEntry 10 }
snVLanByIpSubnetChassisExcludeMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(32))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Chassis VLAN By Subnet port membership applied in exclusive mode.
(It was obsoleted after release 07100, replaced by snVLanByIpSubnetExcludePortList)"
::= { snVLanByIpSubnetEntry 11 }
snVLanByIpSubnetChassisDynamicMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(32))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The Chassis VLAN By Subnet active port membership.
(It was obsoleted after release 07100, replaced by snVLanByIpSubnetDynamicPortList)"
::= { snVLanByIpSubnetEntry 12 }
snVLanByIpSubnetVLanName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VLAN Community Name string."
::= { snVLanByIpSubnetEntry 13 }
snVLanByIpSubnetStaticPortList OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A list of port indices which are the configured port
membership of the VLAN By IP Subnet. Each port index is a
16-bit integer in big endian order. 8-bit is the slot number,
the other 8-bit is the port number."
::= { snVLanByIpSubnetEntry 14 }
snVLanByIpSubnetExcludePortList OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A list of port indices which are the excluded from port
membership of the VLAN By IP Subnet. Each port index is a
16-bit integer in big endian order. 8-bit is the slot number,
the other 8-bit is the port number."
::= { snVLanByIpSubnetEntry 15 }
snVLanByIpSubnetDynamicPortList OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A list of port indices which are dynamically joining the port
membership of the VLAN By IP Subnet. Each port index is a
16-bit integer in big endian order. 8-bit is the slot number,
the other 8-bit is the port number."
::= { snVLanByIpSubnetEntry 16 }
-- VLAN By IPX Net Configuration Table
snVLanByIpxNetTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnVLanByIpxNetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of the VLAN By IPX Network Number Table."
::= { snVLanInfo 4 }
snVLanByIpxNetEntry OBJECT-TYPE
SYNTAX SnVLanByIpxNetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the VLAN By Ipx Network Number Configuration table. "
INDEX {
snVLanByIpxNetVLanId,
snVLanByIpxNetNetworkNum,
snVLanByIpxNetFrameType
}
::= { snVLanByIpxNetTable 1 }
SnVLanByIpxNetEntry ::= SEQUENCE {
snVLanByIpxNetVLanId
INTEGER,
snVLanByIpxNetNetworkNum
OCTET STRING,
snVLanByIpxNetFrameType
INTEGER,
snVLanByIpxNetDynamic
INTEGER,
snVLanByIpxNetStaticMask
PortMask,
snVLanByIpxNetExcludeMask
PortMask,
snVLanByIpxNetRouterIntf
INTEGER,
snVLanByIpxNetRowStatus
INTEGER,
snVLanByIpxNetDynamicMask
PortMask,
snVLanByIpxNetChassisStaticMask
OCTET STRING,
snVLanByIpxNetChassisExcludeMask
OCTET STRING,
snVLanByIpxNetChassisDynamicMask
OCTET STRING,
snVLanByIpxNetVLanName
DisplayString,
snVLanByIpxNetStaticPortList
OCTET STRING,
snVLanByIpxNetExcludePortList
OCTET STRING,
snVLanByIpxNetDynamicPortList
OCTET STRING
}
snVLanByIpxNetVLanId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The VLAN ID index to both of the VLAN By Port Info Table
and this table."
::= { snVLanByIpxNetEntry 1 }
snVLanByIpxNetNetworkNum OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IPX Network Number."
::= { snVLanByIpxNetEntry 2 }
snVLanByIpxNetFrameType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(0),
ipxEthernet8022(1),
ipxEthernet8023(2),
ipxEthernetII(3),
ipxEthernetSnap(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The following IPX Frame types are operated
in Layer3 VLAN such as :
ipxEthernet8022(1), ipxEthernet8023(2),
ipxEthernetII(3), ipxEthernetSnap(4).
choose notApplicable(0) for other protocols.
Note: Each Network Number can be assigned with one unique Frame type; Otherwise,
a SNMP-SET error will be returned."
::= { snVLanByIpxNetEntry 3 }
snVLanByIpxNetDynamic OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" disabled(0) : disabled dynamic port inclusion - applied to switch only.
enabled(1) : enabled dynamic port inclusion - applied to switch only. "
::= { snVLanByIpxNetEntry 4 }
snVLanByIpxNetStaticMask OBJECT-TYPE
SYNTAX PortMask
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The VLAN By IPX network port membership applied in static mode.
(It was obsoleted for Chassis Product)"
::= { snVLanByIpxNetEntry 5 }
snVLanByIpxNetExcludeMask OBJECT-TYPE
SYNTAX PortMask
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The VLAN By IPX network port membership applied in exclusive mode.
(It was obsoleted for Chassis Product)"
::= { snVLanByIpxNetEntry 6 }
snVLanByIpxNetRouterIntf OBJECT-TYPE
SYNTAX INTEGER (1..60)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Optional: A virtual interface for router to the VLAN -- applied to router only.
If a SNMP-Get value is zero, that means this object was not configured."
::= { snVLanByIpxNetEntry 7 }
snVLanByIpxNetRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4),
modify(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to create and
delete row in the table and control
if they are used. The values
that can be written are:
delete(3)...deletes the row
create(4)...creates a new row
modify(5)...modifies an exsisting row
If the row exists, then a SET with
value of create(4) returns error
'badValue'. Deleted rows go away
immediately. The following values
can be returned on reads:
noSuch(0)...no such row
other(1)....some other case
valid(2)....the row exists and is valid"
::= { snVLanByIpxNetEntry 8 }
snVLanByIpxNetDynamicMask OBJECT-TYPE
SYNTAX PortMask
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The VLAN By IPX network active port membership.
(It was obsoleted for Chassis Product)"
::= { snVLanByIpxNetEntry 9 }
snVLanByIpxNetChassisStaticMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(32))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Chassis VLAN By IPX network port membership applied in static mode.
(It was obsoleted after release 07100, replaced by snVLanByIpxNetStaticPortList)"
::= { snVLanByIpxNetEntry 10 }
snVLanByIpxNetChassisExcludeMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(32))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Chassis VLAN By IPX network port membership applied in exclusive mode.
(It was obsoleted after release 07100, replaced by snVLanByIpxNetExcludePortList)"
::= { snVLanByIpxNetEntry 11 }
snVLanByIpxNetChassisDynamicMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(32))
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The Chassis VLAN By IPX network active port membership.
(It was obsoleted after release 07100, replaced by snVLanByIpxNetDynamicPortList)"
::= { snVLanByIpxNetEntry 12 }
snVLanByIpxNetVLanName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VLAN Community Name string."
::= { snVLanByIpxNetEntry 13 }
snVLanByIpxNetStaticPortList OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A list of port indices which are the configured port
membership of the VLAN By IPX network. Each port index is a
16-bit integer in big endian order. 8-bit is the slot number,
the other 8-bit is the port number."
::= { snVLanByIpxNetEntry 14 }
snVLanByIpxNetExcludePortList OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A list of port indices which are the excluded from port
membership of the VLAN By IPX network. Each port index is a
16-bit integer in big endian order. 8-bit is the slot number,
the other 8-bit is the port number."
::= { snVLanByIpxNetEntry 15 }
snVLanByIpxNetDynamicPortList OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A list of port indices which are dynamically joining the port
membership of the VLAN By IPX network. Each port index is a
16-bit integer in big endian order. 8-bit is the slot number,
the other 8-bit is the port number."
::= { snVLanByIpxNetEntry 16 }
-- VLAN By AppleTalk Cable Configuration Table
snVLanByATCableTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnVLanByATCableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A Table Of VLAN By AppleTalk Network Number."
::= { snVLanInfo 5 }
snVLanByATCableEntry OBJECT-TYPE
SYNTAX SnVLanByATCableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of the AppleTalk Cable VLAN table."
INDEX {snVLanByATCableVLanId, snVLanByATCableIndex}
::= { snVLanByATCableTable 1 }
SnVLanByATCableEntry ::= SEQUENCE {
snVLanByATCableVLanId
INTEGER,
snVLanByATCableIndex
INTEGER,
snVLanByATCableRouterIntf
INTEGER,
snVLanByATCableRowStatus
INTEGER,
snVLanByATCableChassisStaticMask
OCTET STRING,
snVLanByATCableVLanName
DisplayString,
snVLanByATCableStaticPortList
OCTET STRING
}
snVLanByATCableVLanId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The VLAN ID of a PORT VLAN of which the AppleTalk Cable
VLAN was attaching to."
::= { snVLanByATCableEntry 1 }
snVLanByATCableIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"AppleTalk Cable VLAN index number."
::= { snVLanByATCableEntry 2 }
snVLanByATCableRouterIntf OBJECT-TYPE
SYNTAX INTEGER (0..60)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A virtual router interface to the AppleTalk Cable VLAN,
only router products accept the SNMP-SET operation. The
value zero indicates that virtual router interface was
not configured."
::= { snVLanByATCableEntry 3 }
snVLanByATCableRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4),
modify(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to create and
delete row in the table and control
if they are used. The values
that can be written are:
delete(3)...deletes the row
create(4)...creates a new row
modify(5)...modifies an exsisting row
If the row exists, then a SET with
value of create(4) returns error
'badValue'. Deleted rows go away
immediately. The following values
can be returned on reads:
noSuch(0)...no such row
other(1)....some other case
valid(2)....the row exists and is valid"
::= { snVLanByATCableEntry 4 }
snVLanByATCableChassisStaticMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(32))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"A list of ports which are statically configured to
become port members of a VLAN.
(It was obsoleted after release 07100, replaced by snVLanByATCableStaticPortList)"
::= { snVLanByATCableEntry 5 }
snVLanByATCableVLanName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VLAN Name string."
::= { snVLanByATCableEntry 6 }
snVLanByATCableStaticPortList OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A list of port indices which are the configured port
membership of the AppleTalk Cable VLAN. Each port index is a
16-bit integer in big endian order. 8-bit is the slot number,
the other 8-bit is the port number."
::= { snVLanByATCableEntry 7 }
-- Switch Port Information Group
snSwPortInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnSwPortInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A specific snSwPortInfo group consists of a number of
switch ports. "
::= { snSwPortInfo 1 }
snSwPortInfoEntry OBJECT-TYPE
SYNTAX SnSwPortInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the snSwPortInfo table indicates the
configuration on a specified port. A SNMP SET PDU
for a row of the snSwPortInfoTable requires the entired
sequence of the MIB Objects in each
snSwPortInfoEntry stored in one PDU. Otherwise,
GENERR return-value will be returned."
INDEX {
snSwPortInfoPortNum
}
::= { snSwPortInfoTable 1 }
SnSwPortInfoEntry ::= SEQUENCE {
snSwPortInfoPortNum
INTEGER,
snSwPortInfoMonitorMode
INTEGER,
snSwPortInfoTagMode
INTEGER,
snSwPortInfoChnMode
INTEGER,
snSwPortInfoSpeed
INTEGER,
snSwPortInfoMediaType
INTEGER,
snSwPortInfoConnectorType
INTEGER,
snSwPortInfoAdminStatus
INTEGER,
snSwPortInfoLinkStatus
INTEGER,
snSwPortInfoPortQos
INTEGER,
snSwPortInfoPhysAddress
PhysAddress,
snSwPortStatsInFrames
Counter,
snSwPortStatsOutFrames
Counter,
snSwPortStatsAlignErrors
Counter,
snSwPortStatsFCSErrors
Counter,
snSwPortStatsMultiColliFrames
Counter,
snSwPortStatsFrameTooLongs
Counter,
snSwPortStatsTxColliFrames
Counter,
snSwPortStatsRxColliFrames
Counter,
snSwPortStatsFrameTooShorts
Counter,
snSwPortLockAddressCount
INTEGER,
snSwPortStpPortEnable
INTEGER,
snSwPortDhcpGateListId
INTEGER,
snSwPortName
DisplayString,
snSwPortStatsInBcastFrames
Counter,
snSwPortStatsOutBcastFrames
Counter,
snSwPortStatsInMcastFrames
Counter,
snSwPortStatsOutMcastFrames
Counter,
snSwPortStatsInDiscard
Counter,
snSwPortStatsOutDiscard
Counter,
snSwPortStatsMacStations
INTEGER,
snSwPortCacheGroupId
INTEGER,
snSwPortTransGroupId
INTEGER,
snSwPortInfoAutoNegotiate
INTEGER,
snSwPortInfoFlowControl
INTEGER,
snSwPortInfoGigType
INTEGER,
snSwPortStatsLinkChange
Counter,
snSwPortIfIndex
INTEGER,
snSwPortDescr
DisplayString,
snSwPortInOctets
OCTET STRING,
snSwPortOutOctets
OCTET STRING,
snSwPortStatsInBitsPerSec
Gauge,
snSwPortStatsOutBitsPerSec
Gauge,
snSwPortStatsInPktsPerSec
Gauge,
snSwPortStatsOutPktsPerSec
Gauge,
snSwPortStatsInUtilization
INTEGER (0..10000),
snSwPortStatsOutUtilization
INTEGER (0..10000),
snSwPortFastSpanPortEnable
INTEGER,
snSwPortFastSpanUplinkEnable
INTEGER,
snSwPortVlanId
INTEGER,
snSwPortRouteOnly
INTEGER,
snSwPortPresent
INTEGER,
snSwPortGBICStatus
INTEGER,
snSwPortStatsInKiloBitsPerSec
Unsigned32,
snSwPortStatsOutKiloBitsPerSec
Unsigned32,
snSwPortLoadInterval
INTEGER (30..300),
snSwPortTagType
INTEGER
}
snSwPortInfoPortNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port index.
The bit 0 to bit 7: port number.
The bit 8 to bit 11: slot number (slot for chassis only)."
::= { snSwPortInfoEntry 1 }
snSwPortInfoMonitorMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
input(1),
output(2),
both(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A monitoring port is selected and its traffic will be
analyzed if the mode is not disabled(0), which is
the default mode.
The values are:
disabled(0) -- No traffic monitoring
input(1) -- traffic monitoring is activated on packets received
output(2) -- traffic monitoring is activated on packets transmitted
both(3) -- traffic monitoring is activated on packets
received and transmitted."
::= { snSwPortInfoEntry 2 }
snSwPortInfoTagMode OBJECT-TYPE
SYNTAX INTEGER {
tagged(1),
untagged(2),
auto(3),
disabled(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"For tagged port, we could have multiple VLANs
per port. For untagged port or auto port, there
is only one VLAN ID per port."
::= { snSwPortInfoEntry 3 }
snSwPortInfoChnMode OBJECT-TYPE
SYNTAX INTEGER {
none(0),
halfDuplex(1),
fullDuplex(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The port can be configured to operate in either
half or full duplex mode. The values are:
halfDuplex(1)...half duplex mode
fullDuplex(2)...full duplex mode
The read-back channel status from hardware are:
none(0).........link down or port disabled.
halfDuplex(1)...half duplex mode
fullDuplex(2)...full duplex mode
The port media type (expansion or regular)
and port link type (trunk or feeder) determine
value of this object.
The port can not set to half duplex mode
if the port connect mode is m200e(4).
However, the value of this parameter may be
automatically set whenever the expansion port
is connected (e.g. cascade connecting device)."
::= { snSwPortInfoEntry 4 }
snSwPortInfoSpeed OBJECT-TYPE
SYNTAX INTEGER {
none(0),
sAutoSense(1),
s10M(2),
s100M(3),
s1G(4),
s45M(5),
s155M(6),
s10G(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The speed configuration for a port. The values are:
none(0)..........link down or no traffic.
sAutoSense(1)....Auto-sensing 10 or 100Mbits.
s10M(2)..........10Mbits per second.
s100M(3).........100Mbits per second.
s1G(4)...........1Gbits per second.
s45M(5)..........45Mbits per second (T3) (for expansion board only).
s155M(6).........155Mbits per second (ATM) (for expansion board only).
s10G(7)..........10Gbits per second.
The read-back hardware status are the following:
none(0)..........link down or no traffic.
s10M(2)..........10Mbits per second.
s100M(3).........100Mbits per second.
s1G(4)...........1Gbits per second.
s45M(5)..........45Mbits per second (T3) (for expansion board only).
s155M(6).........155Mbits per second (ATM) (for expansion board only).
s10G(7)..........10Gbits per second.
The port media type (expansion or regular)
and port link type (trunk or feeder) determine
whether this object can be written and the valid
values.
It is not allowed to change speed for trunks ports.
For expansion ports, all of the above speed
can be set.
However, the value of this parameter may be
automatically set whenever the expansion port
is connected (e.g. cascade connecting device)."
::= { snSwPortInfoEntry 5 }
snSwPortInfoMediaType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
m100BaseTX(2),
m100BaseFX(3),
m1000BaseFX(4),
mT3(5),
m155ATM(6),
m1000BaseTX(7),
m622ATM(8),
m155POS(9),
m622POS(10),
m2488POS(11),
m10000BaseFX(12)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The media type for the port. The
values are:
other(1).........other or unknown media.
m100BaseTX(2)....100Mbits per second copper.
m100BaseFX(3)....100Mbits per second fiber.
m1000BaseFX(4)...1Gbits per second fiber.
mT3(5)...........45Mbits per second (T3).
m155ATM(6).......155Mbits per second (ATM).
m1000BaseTX(7)...1Gbits per second copper.
m622ATM(8).......622Mbits per second (ATM).
m155POS(9).......155Mbits per second (POS).
m622POS(10)......622Mbits per second (POS).
m2488POS(11).....2488Mbits per second (POS).
m10000BaseFX(12).10Gbits per second fiber."
::= { snSwPortInfoEntry 6 }
snSwPortInfoConnectorType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
copper(2),
fiber(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of connector that the port offers.
The values are:
other(1)...........other or unknown connector
copper(2)..........Copper connector
fiber(3)...........Fiber connector
This describes the physical connector type"
::= { snSwPortInfoEntry 7 }
snSwPortInfoAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1), -- ready to pass packets
down(2),
testing(3) -- in some test mode
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The desired state of all ports. The
testing(3) state indicates that no operational
packets can be passed.
(same as ifAdminStatus in MIB-II)"
::= { snSwPortInfoEntry 8 }
snSwPortInfoLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1), -- ready to pass packets
down(2),
testing(3) -- in some test mode
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current operational state of the interface.
The testing(3) state indicates that no operational
packets can be passed.
(same as ifOperStatus in MIB-II)"
::= { snSwPortInfoEntry 9 }
snSwPortInfoPortQos OBJECT-TYPE
SYNTAX INTEGER {
level0(0),
level1(1),
level2(2),
level3(3),
level4(4),
level5(5),
level6(6),
level7(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Stand alone stackable switch Port Qos Priority values are:
low(0) -- low prority
high(1) -- high prority.
The BigIron Port Qos Priority values are:
level0(0), level1(1), level2(2), level3(3),
level4(4), level5(5), level6(6), level7(7) "
::= { snSwPortInfoEntry 10 }
snSwPortInfoPhysAddress OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port physical address. The physical address
represents the switch port."
::= { snSwPortInfoEntry 11 }
snSwPortStatsInFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets received on the interface."
::= { snSwPortInfoEntry 12 }
snSwPortStatsOutFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets transmitted out of the interface."
::= { snSwPortInfoEntry 13 }
snSwPortStatsAlignErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dot3StatsAlignmentErrors : A count of frames
received on a particular interface that are
not an integral number of octets in length
and do not pass the FCS check.
The count represented by an instance of this
object is incremented when the alignmentError
status is returned by the MAC service to the
LLC (or other MAC user). Received frames for
which multiple error conditions obtain are,
according to the conventions of IEEE 802.3
Layer Management, counted exclusively according
to the error status presented to the LLC."
::= { snSwPortInfoEntry 14 }
snSwPortStatsFCSErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dot3StatsFCSErrors : A count of frames received
on a particular interface that are an integral
number of octets in length but do not pass the
FCS check.
The count represented by an instance of this
object is incremented when the frameCheckError
status is returned by the MAC service to the
LLC (or other MAC user). Received frames for
which multiple error conditions obtain are,
according to the conventions of IEEE 802.3
Layer Management, counted exclusively according
to the error status presented to the LLC."
::= { snSwPortInfoEntry 15 }
snSwPortStatsMultiColliFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dot3StatsMultipleCollisionFrames :
A count of successfully transmitted frames on
a particular interface for which transmission
is inhibited by more than one collision.
A frame that is counted by an instance of this
object is also counted by the corresponding
instance of either the ifOutUcastPkts,
ifOutMulticastPkts, or ifOutBroadcastPkts,
and is not counted by the corresponding
instance of the dot3StatsSingleCollisionFrames
object."
::= { snSwPortInfoEntry 16 }
snSwPortStatsFrameTooLongs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dot3StatsFrameTooLongs : A count of frames
received on a particular interface that
exceed the maximum permitted frame size.
The count represented by an instance of this
object is incremented when the frameTooLong
status is returned by the MAC service to the
LLC (or other MAC user). Received frames for
which multiple error conditions obtain are,
according to the conventions of IEEE 802.3
Layer Management, counted exclusively according
to the error status presented to the LLC."
::= { snSwPortInfoEntry 17 }
snSwPortStatsTxColliFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count of successfully transmitted frames on
a particular interface for which transmission
is inhibited by more than one collision.
A frame that is counted by a combination of
both dot3StatsSingleCollisionFrames and
dot3StatsMultipleCollisionFrames objects."
::= { snSwPortInfoEntry 18 }
snSwPortStatsRxColliFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count of successfully received frames on
a particular interface for which transmission
is inhibited by more than one collision. This
object is not specified in dot3 but it has the
same functionarity as snSwPortStatsTxColliFrames."
::= { snSwPortInfoEntry 19 }
snSwPortStatsFrameTooShorts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" A count of frames received on a particular
interface that below the minimum permitted
frame size."
::= { snSwPortInfoEntry 20 }
snSwPortLockAddressCount OBJECT-TYPE
SYNTAX INTEGER (0..2048)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of source MAC addresses are allowed
for a port. Writing 0 to this object will allow
any number of addresses."
DEFVAL { 8 }
::= { snSwPortInfoEntry 21 }
snSwPortStpPortEnable OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The enabled/disabled status of the port."
REFERENCE
"IEEE 802.1D-1990: Section 4.5.5.2, dot1dStpPortEnable"
::= { snSwPortInfoEntry 22 }
snSwPortDhcpGateListId OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The ID for a DHCP gateway list entry relative
to this switch port. 0 = unset or no assigned ID"
::= { snSwPortInfoEntry 23 }
snSwPortName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port Name string."
::= { snSwPortInfoEntry 24 }
snSwPortStatsInBcastFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of broadcast packets received on the interface."
::= { snSwPortInfoEntry 25 }
snSwPortStatsOutBcastFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of broadcast packets transmitted out of the interface."
::= { snSwPortInfoEntry 26 }
snSwPortStatsInMcastFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of multicast packets received on the interface."
::= { snSwPortInfoEntry 27 }
snSwPortStatsOutMcastFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of multicast packets transmitted out of the interface."
::= { snSwPortInfoEntry 28 }
snSwPortStatsInDiscard OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of inbound packets which were chosen
to be discarded even though no errors had been
detected to prevent their being deliverable to a
higher-layer protocol. One possible reason for
discarding such a packet could be to free up
buffer space."
::= { snSwPortInfoEntry 29 }
snSwPortStatsOutDiscard OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of outbound packets which were chosen
to be discarded even though no errors had been
detected to prevent their being transmitted. One
possible reason for discarding such a packet could
be to free up buffer space."
::= { snSwPortInfoEntry 30 }
snSwPortStatsMacStations OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of MAC Stations connected to the interface."
::= { snSwPortInfoEntry 31 }
snSwPortCacheGroupId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Cache Group ID for the interface."
::= { snSwPortInfoEntry 32 }
snSwPortTransGroupId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Transparent Group ID for the interface."
::= { snSwPortInfoEntry 33 }
snSwPortInfoAutoNegotiate OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1),
negFullAuto(2),
global(3),
other(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This feature only applies to Gigabit Ethernet ports. If set to
disable(0), port will be put to non-negotiation mode. If set to
enable(1), port will start auto-negotiation indefinitely until
succeed. If set to negFullAuto(2), the port will start with auto-
negotiation, if the negotiation failed, then it will automatically
switch to non-negotiation mode. Stackable products (except TurboIron
8) Gigabit Ethernet ports do not support negFullAuto(2). If set
to global(3), port negotiation mode follows the value of
snSwGlobalAutoNegotiate. Non-Gigabit Ethernet port returns
the value other(4)."
DEFVAL { global }
::= { snSwPortInfoEntry 34 }
snSwPortInfoFlowControl OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/Disbale port flow control."
DEFVAL { enabled }
::= { snSwPortInfoEntry 35 }
snSwPortInfoGigType OBJECT-TYPE
SYNTAX INTEGER {
m1000BaseSX(0),
m1000BaseLX(1),
m1000BaseLH(2),
m1000BaseLHA(3),
m1000BaseLHB(4),
m1000BaseTX(5),
m10000BaseSR(6),
m10000BaseLR(7),
m10000BaseER(8),
notApplicable(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The media type for the port. The
values are:
m1000BaseSX(0)....1Gbits per second fiber, with a short wavelength transceiver.
m1000BaseLX(1)....1Gbits per second fiber, with a long wavelength transceiver (3km).
m1000BaseLH(2)....1Gbits per second fiber, with a special wavelength transceiver (50km).
m1000BaseLHA(3)....1Gbits per second fiber, with a special wavelength transceiver (70km).
m1000BaseLHB(4)....1Gbits per second fiber, with a special wavelength transceiver (150km).
m1000BaseTX(5)....1Gbits per second copper (100meter).
m10000BaseSR(6)....10Gbits per second fiber, with a short range wavelength transceiver (100m).
m10000BaseLR(7)....10Gbits per second fiber, with a long range wavelength transceiver (10km).
m10000BaseER(8)....10Gbits per second fiber, with a extended range wavelength transceiver (40km).
notApplicable(255)....a non-gigabit port."
::= { snSwPortInfoEntry 36 }
snSwPortStatsLinkChange OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of link state change of the interface."
::= { snSwPortInfoEntry 37 }
snSwPortIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"In order to identify a particular interface, this
object shall identify the instance of the ifIndex
object, defined in RFC 1213 and RFC 1573."
::= { snSwPortInfoEntry 38 }
snSwPortDescr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual string containing the slot/port information
about the interface."
::= { snSwPortInfoEntry 39 }
snSwPortInOctets OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of octets received on the interface,
including framing characters. This object is a 64-bit
counter of the ifInOctets object, defined in RFC 1213.
The octet string is in big-endian byte order."
::= { snSwPortInfoEntry 40 }
snSwPortOutOctets OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of octets transmitted out of the interface,
including framing characters. This object is a 64-bit
counter of the ifOutOctets object, defined in RFC 1213.
The octet string is in big-endian byte order."
::= { snSwPortInfoEntry 41 }
snSwPortStatsInBitsPerSec OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bits per second received on the interface
over a 5 minutes interval."
::= { snSwPortInfoEntry 42 }
snSwPortStatsOutBitsPerSec OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bits per second transmitted out of the interface
over a 5 minutes interval."
::= { snSwPortInfoEntry 43 }
snSwPortStatsInPktsPerSec OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets per second received on the interface
over a 5 minutes interval."
::= { snSwPortInfoEntry 44 }
snSwPortStatsOutPktsPerSec OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets per second transmitted out of the interface
over a 5 minutes interval."
::= { snSwPortInfoEntry 45 }
snSwPortStatsInUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The input network utilization in hundredths of a percent
over a 5 minutes interval."
::= { snSwPortInfoEntry 46 }
snSwPortStatsOutUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The output network utilization in hundredths of a percent
over a 5 minutes interval."
::= { snSwPortInfoEntry 47 }
snSwPortFastSpanPortEnable OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The enabled/disabled fast span port status of the port."
::= { snSwPortInfoEntry 48 }
snSwPortFastSpanUplinkEnable OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The enabled/disabled fast span uplink status of the port."
::= { snSwPortInfoEntry 49 }
snSwPortVlanId OBJECT-TYPE
SYNTAX INTEGER (0..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The ID of a VLAN of which this port is a member. Port must
be untagged. For tagged port which belongs to multiple
VLANs, this object return 0 which is an invalid VLAN ID
value."
::= { snSwPortInfoEntry 50 }
snSwPortRouteOnly OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/Disable L2 switching of a routing switch port.
By default, the routing switch performs routing first.
If routing failed, it performs switching. Enable route
only instrcuts the routing switch to perform routing
only. For a L2 switching only product, reading this
object always return 'disabled', writing 'enabled' to
this object takes no effect."
DEFVAL { disabled }
::= { snSwPortInfoEntry 51 }
snSwPortPresent OBJECT-TYPE
SYNTAX INTEGER {
false(0),
true(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicate if the port is absent or present.
This object only valid for M4 module
"
::= { snSwPortInfoEntry 52 }
snSwPortGBICStatus OBJECT-TYPE
SYNTAX INTEGER {
gbic(1),
miniGBIC(2),
empty(3),
other(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicate if the gig port has GBICs on them.
If set to GBIC(1), it means that the port is GBIC.
If set to miniGBIC(2), it means that the port miniGBIC.
If set to empty(3), it means that the GBIC is missing.
Value other(4) means that the port not a removable gig port.
"
::= { snSwPortInfoEntry 53 }
snSwPortStatsInKiloBitsPerSec OBJECT-TYPE
SYNTAX Unsigned32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bit rate in kilobits per second received on the 10G and faster interface
over a 5 minutes interval."
::= { snSwPortInfoEntry 54 }
snSwPortStatsOutKiloBitsPerSec OBJECT-TYPE
SYNTAX Unsigned32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bit rate in kilobits per second transmitted out of the 10G and faster interface
over a 5 minutes interval."
::= { snSwPortInfoEntry 55 }
snSwPortLoadInterval OBJECT-TYPE
SYNTAX INTEGER (30..300)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time in seconds for which average port utilization should be carried out.
The value should be incremental of 30 seconds, between the ranges specified."
DEFVAL { 300 }
::= { snSwPortInfoEntry 56 }
snSwPortTagType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IEEE802.1q tag type embedded in the length/type field of
an Ethernet packet. It specifies that the 2 octets after the
length/type field in an Ethernet packet is the tag value."
DEFVAL { 33024 }
::= { snSwPortInfoEntry 57 }
-- Interface ID Registration Group
snInterfaceId OBJECT IDENTIFIER ::= { snSwPortInfo 2 }
-- Interface ID to ifIndex Lookup Table
-- Given an interface ID, this table returns the ifIndex value.
--
-- Note: This table does not behave like most SNMP tables. It does not
-- support GetNext. If you try to walk the table using GetNext, no rows
-- will be returned. The contents of the table can only be accessed
-- using Get operations. The table is useful for mapping a known
-- interface to the corresponding ifIndex value.
snInterfaceLookupTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnInterfaceLookupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { snSwPortInfo 3 }
snInterfaceLookupEntry OBJECT-TYPE
SYNTAX SnInterfaceLookupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { snInterfaceLookupInterfaceId }
::= { snInterfaceLookupTable 1 }
SnInterfaceLookupEntry ::= SEQUENCE {
snInterfaceLookupInterfaceId
InterfaceId,
snInterfaceLookupIfIndex
INTEGER
}
snInterfaceLookupInterfaceId OBJECT-TYPE
SYNTAX InterfaceId
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { snInterfaceLookupEntry 1 }
snInterfaceLookupIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { snInterfaceLookupEntry 2 }
-- ifIndex to Interface ID Lookup Table
-- Given an ifIndex, this table returns the interface ID value.
snIfIndexLookupTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnIfIndexLookupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { snSwPortInfo 4 }
snIfIndexLookupEntry OBJECT-TYPE
SYNTAX SnIfIndexLookupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { snIfIndexLookupIfIndex }
::= { snIfIndexLookupTable 1 }
SnIfIndexLookupEntry ::= SEQUENCE {
snIfIndexLookupIfIndex
INTEGER,
snIfIndexLookupInterfaceId
InterfaceId
}
snIfIndexLookupIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { snIfIndexLookupEntry 1 }
snIfIndexLookupInterfaceId OBJECT-TYPE
SYNTAX InterfaceId
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { snIfIndexLookupEntry 2 }
-- Forwarding Database Group
--
-- This group contains information relevant to
-- the forwarding database in the system.
-- The Forward Database Static Table Information
--
-- This table contains all MAC addresses in the system. Static
-- stations may be configured.
snFdbTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnFdbEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains snFdb information for each station
known to the system, one entry per station."
::= { snFdbInfo 1 }
snFdbEntry OBJECT-TYPE
SYNTAX SnFdbEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry represents the information of a static MAC station."
INDEX {
snFdbStationIndex
}
::= { snFdbTable 1 }
SnFdbEntry ::= SEQUENCE {
snFdbStationIndex
INTEGER,
snFdbStationAddr
PhysAddress,
snFdbStationPort
INTEGER,
snFdbVLanId
INTEGER,
snFdbStationQos
INTEGER,
snFdbStationType
INTEGER,
snFdbRowStatus
INTEGER
}
snFdbStationIndex OBJECT-TYPE
SYNTAX INTEGER (1..256)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The FDB Station index to the Fdb Station Table."
::= { snFdbEntry 1 }
snFdbStationAddr OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The snFdbs physical address. The physical address
represents a MAC Station."
::= { snFdbEntry 2 }
snFdbStationPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Station slot/port number.
The bit 0 to bit 7: port number.
The bit 8 to bit 11: slot number (slot for chassis only)."
::= { snFdbEntry 3 }
snFdbVLanId OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Station VLan ID."
::= { snFdbEntry 4 }
snFdbStationQos OBJECT-TYPE
SYNTAX INTEGER {
level0(0),
level1(1),
level2(2),
level3(3),
level4(4),
level5(5),
level6(6),
level7(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Stand alone stackable station Qos Priority values are:
low(0) -- low prority
high(1) -- high prority.
The BigIron switch station Priority values are:
level0(0), level1(1), level2(2), level3(3),
level4(4), level5(5), level6(6), level7(7) "
::= { snFdbEntry 5 }
snFdbStationType OBJECT-TYPE
SYNTAX INTEGER {
notSupported(0),
host(1),
router(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The station type values are:
notSupported -- a read value only : this product does not
support MultiLayer Switching.
host -- any MAC station.
router -- a router-typed station."
::= { snFdbEntry 6 }
snFdbRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to create and
delete row in the table and control
if they are used. The values
that can be written are:
delete(3)...deletes the row
create(4)...creates a new row
If the row exists, then a SET with
value of create(4) returns error
'badValue'. Deleted rows go away
immediately. The following values
can be returned on reads:
noSuch(0)...no such row
other(1)....some other case
valid(2)....the row exists and is valid"
::= { snFdbEntry 7 }
-- Port STP Configuration Group
snPortStpTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnPortStpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A specific snPortStpTable consists of a number of
switch ports. This table only exists if only if
snVLanByPortTable exists and snVLanByPortStpMode is
enabled for each VLAN."
::= { snPortStpInfo 1 }
snPortStpEntry OBJECT-TYPE
SYNTAX SnPortStpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the snPortStpTable indicates the
configuration on a specified port. A SNMP SET PDU
for a row of the snPortStpTable requires the entired
sequence of the MIB Objects in each
snPortStpEntry stored in one PDU. Otherwise,
GENERR return-value will be returned."
INDEX {
snPortStpVLanId,
snPortStpPortNum
}
::= { snPortStpTable 1 }
SnPortStpEntry ::= SEQUENCE {
snPortStpVLanId
INTEGER,
snPortStpPortNum
INTEGER,
snPortStpPortPriority
INTEGER,
snPortStpPathCost
INTEGER,
snPortStpOperState
INTEGER,
snPortStpPortEnable
INTEGER,
snPortStpPortForwardTransitions
Counter,
snPortStpPortState
INTEGER,
snPortStpPortDesignatedCost
INTEGER,
snPortStpPortDesignatedRoot
BridgeId,
snPortStpPortDesignatedBridge
BridgeId,
snPortStpPortDesignatedPort
OCTET STRING
}
snPortStpVLanId OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The VLAN ID of the VLAN switch community."
::= { snPortStpEntry 1 }
snPortStpPortNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port number of the Switch.
The bit 0 to bit 7: port number.
The bit 8 to bit 11: slot number (slot for chassis only)."
::= { snPortStpEntry 2 }
snPortStpPortPriority OBJECT-TYPE
SYNTAX INTEGER (8..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of the priority field which is
contained in the first (in network byte order)
octet of the (2 octet long) Port ID. The other
octet of the Port ID is given by the value of
dot1dStpPort."
::= { snPortStpEntry 3 }
snPortStpPathCost OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"dot1dStpPortPathCost : The contribution of this
port to the path cost of paths towards the spanning
tree root which include this port. 802.1D-1990
recommends that the default value of this parameter
be in inverse proportion to the speed of the
attached LAN. Writing value zero to this object
sets path cost to a default value which automatically
changes according to port speed. Reading value zero
indicates an unknown path cost value because port
speed cannot be determined due to speed auto sense
in progress."
::= { snPortStpEntry 4 }
snPortStpOperState OBJECT-TYPE
SYNTAX INTEGER {
notActivated(0),
activated(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"By default, this mode is set to notActivated(0).
notActivated(0)...the Port STP entry is not activated and not in running mode.
activated(1)......the Port STP entry is activated and in running mode"
::= { snPortStpEntry 5 }
snPortStpPortEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The enabled/disabled status of the port."
::= { snPortStpEntry 6 }
snPortStpPortForwardTransitions OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of times this port has transitioned
from the Learning state to the Forwarding state."
::= { snPortStpEntry 7 }
snPortStpPortState OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
blocking(2),
listening(3),
learning(4),
forwarding(5),
broken(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port's current state as defined by
application of the Spanning Tree Protocol. This
state controls what action a port takes on
reception of a frame. If the bridge has detected
a port that is malfunctioning it will place that
port into the broken(6) state. For ports which
are disabled (see dot1dStpPortEnable), this object
will have a value of disabled(1)."
::= { snPortStpEntry 8 }
snPortStpPortDesignatedCost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The path cost of the Designated Port of the
segment connected to this port. This value is
compared to the Root Path Cost field in received
bridge PDUs."
::= { snPortStpEntry 9 }
snPortStpPortDesignatedRoot OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique Bridge Identifier of the Bridge
recorded as the Root in the Configuration BPDUs
transmitted by the Designated Bridge for the
segment to which the port is attached."
::= { snPortStpEntry 10 }
snPortStpPortDesignatedBridge OBJECT-TYPE
SYNTAX BridgeId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bridge Identifier of the bridge which this
port considers to be the Designated Bridge for
this port's segment."
::= { snPortStpEntry 11 }
snPortStpPortDesignatedPort OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Port Identifier of the port on the Designated
Bridge for this port's segment."
::= { snPortStpEntry 12 }
-- Trunk Port Configuration Group
snTrunkTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnTrunkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A specific snTrunkTable consists of a number of
Trunk port-mask."
::= { snTrunkInfo 1 }
snTrunkEntry OBJECT-TYPE
SYNTAX SnTrunkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the snTrunkTable indicates the
configuration on a specified Trunk port membership."
INDEX {
snTrunkIndex
}
::= { snTrunkTable 1 }
SnTrunkEntry ::= SEQUENCE {
snTrunkIndex
INTEGER,
snTrunkPortMask
PortMask,
snTrunkType
INTEGER
}
snTrunkIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of the trunk entries can be configured."
::= { snTrunkEntry 1 }
snTrunkPortMask OBJECT-TYPE
SYNTAX PortMask
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Trunk membership of the Switch."
::= { snTrunkEntry 2 }
snTrunkType OBJECT-TYPE
SYNTAX INTEGER {
switch(1),
server(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The trunk connection type which specifies what
device the trunk ports are connected to."
::= { snTrunkEntry 3 }
-- Multi-slot Trunk Port Configuration Group
snMSTrunkTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnMSTrunkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table contains the configuration of port members of
multi-slot trunk groups."
::= { snTrunkInfo 2 }
snMSTrunkEntry OBJECT-TYPE
SYNTAX SnMSTrunkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of the snMSTrunkTable."
INDEX {snMSTrunkPortIndex}
::= { snMSTrunkTable 1 }
SnMSTrunkEntry ::= SEQUENCE {
snMSTrunkPortIndex
INTEGER,
snMSTrunkPortList
OCTET STRING,
snMSTrunkType
INTEGER,
snMSTrunkRowStatus
INTEGER
}
snMSTrunkPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The primary port of a trunk group. For module with Gig ports,
primary port is port 1, 3, 5, 7. For module with 10/100 ports,
primary port is port 1, 5, 9, 13, 17, 21."
::= { snMSTrunkEntry 1 }
snMSTrunkPortList OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A list of port indices which are the port membership
of a trunk group. Each port index is a 16-bit integer
in big endian order. The first port index must be the
primary port index."
::= { snMSTrunkEntry 2 }
snMSTrunkType OBJECT-TYPE
SYNTAX INTEGER {
switch(1),
server(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The trunk connection type which specifies what
device the trunk ports are connected to."
::= { snMSTrunkEntry 3 }
snMSTrunkRowStatus OBJECT-TYPE
SYNTAX INTEGER {
invalid(1),
valid(2),
delete(3),
create(4),
modify(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To create or delete a table entry."
::= { snMSTrunkEntry 4 }
-- Switch Configuration Summary Group
snSwSummaryMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Switch Group Configuration Summary is configured
either enabled or disabled and the
default is disabled mode.
enabled(1)...........activate Switch Configuration Summary.
disabled(0)..........no Switch Configuration Summary."
::= { snSwSummary 1 }
--- DHCP Gateway List Table
snDhcpGatewayListTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnDhcpGatewayListEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of DHCP gateway list of addresses."
::= { snDhcpGatewayListInfo 1 }
snDhcpGatewayListEntry OBJECT-TYPE
SYNTAX SnDhcpGatewayListEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the IP Port Address table."
INDEX { snDhcpGatewayListId }
::= { snDhcpGatewayListTable 1 }
SnDhcpGatewayListEntry ::= SEQUENCE {
snDhcpGatewayListId
INTEGER,
snDhcpGatewayListAddrList
OCTET STRING,
snDhcpGatewayListRowStatus
INTEGER
}
snDhcpGatewayListId OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ID for a DHCP gateway list entry."
::= { snDhcpGatewayListEntry 1 }
snDhcpGatewayListAddrList OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The DHCP gateway address list for each DHCP gateway list ID.
This list contains 1 to 8 IP addresses represented by octet string."
::= { snDhcpGatewayListEntry 2 }
snDhcpGatewayListRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to create and
delete row in the table and control
if they are used. The values
that can be written are:
delete(3)...deletes the row
create(4)...creates a new row or modifies an exsisting row
If the row exists, then a SET with
value of create(4) returns error
'badValue'. Deleted rows go away
immediately. The following values
can be returned on reads:
noSuch(0)...no such row
other(1)....some other case
valid(2)....the row exists and is valid"
::= { snDhcpGatewayListEntry 3 }
-- DNS MIB Group
snDnsDomainName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DNS Domain Name string."
::= { snDnsInfo 1 }
snDnsGatewayIpAddrList OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The DNS Gateway IP address list. This list contains 4
IP addresses represented by octet string."
::= { snDnsInfo 2 }
-- MAC filter table
snMacFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnMacFilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAC filter table."
::= { snMacFilter 1 }
snMacFilterEntry OBJECT-TYPE
SYNTAX SnMacFilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the MAC filter table."
INDEX { snMacFilterIndex }
::= { snMacFilterTable 1 }
SnMacFilterEntry ::= SEQUENCE {
snMacFilterIndex
INTEGER,
snMacFilterAction
INTEGER,
snMacFilterSourceMac
MacAddress,
snMacFilterSourceMask
MacAddress,
snMacFilterDestMac
MacAddress,
snMacFilterDestMask
MacAddress,
snMacFilterOperator
INTEGER,
snMacFilterFrameType
INTEGER,
snMacFilterFrameTypeNum
INTEGER,
snMacFilterRowStatus
INTEGER
}
snMacFilterIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The table index for a filter entry."
::= { snMacFilterEntry 1 }
snMacFilterAction OBJECT-TYPE
SYNTAX INTEGER { deny(0), permit(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Action to take if the Mac packet match
with this filter."
::= { snMacFilterEntry 2 }
snMacFilterSourceMac OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Source MAC address."
::= { snMacFilterEntry 3 }
snMacFilterSourceMask OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Source MAC subnet mask."
::= { snMacFilterEntry 4 }
snMacFilterDestMac OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Destination MAC address."
::= { snMacFilterEntry 5 }
snMacFilterDestMask OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Destination MAC subnet mask."
::= { snMacFilterEntry 6 }
snMacFilterOperator OBJECT-TYPE
SYNTAX INTEGER { equal(0), notEqual(1), less(2), greater(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Type of comparison to perform."
::= { snMacFilterEntry 7 }
snMacFilterFrameType OBJECT-TYPE
SYNTAX INTEGER{ notUsed(0), ethernet(1), llc(2), snap(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Frame Type: ethernet-type, LLC and SNAP types"
::= { snMacFilterEntry 8 }
snMacFilterFrameTypeNum OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Frame Type Number. 0 means NA"
::= { snMacFilterEntry 9 }
snMacFilterRowStatus OBJECT-TYPE
SYNTAX INTEGER {
invalid(1),
valid(2),
delete(3),
create(4),
modify(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to create and
delete row in the table and control
if they are used. The values
that can be written are:
delete(3)...deletes the row
create(4)...creates a new row
modify(5)...modifies an exsisting row
If the row exists, then a SET with
value of create(4) returns error
'badValue'. Deleted rows go away
immediately. The following values
can be returned on reads:
noSuch(0)...no such row
invalid(1)...Setting it to 'invalid' has the effect of
rendering it inoperative..
valid(2)....the row exists and is valid"
::= { snMacFilterEntry 10 }
-- MAC Filter Port access table
snMacFilterPortAccessTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnMacFilterPortAccessEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAC Filter port access table."
::= { snMacFilter 2 }
snMacFilterPortAccessEntry OBJECT-TYPE
SYNTAX SnMacFilterPortAccessEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the MAC Filter Port access table."
INDEX { snMacFilterPortAccessPortIndex }
::= { snMacFilterPortAccessTable 1 }
SnMacFilterPortAccessEntry ::= SEQUENCE {
snMacFilterPortAccessPortIndex
INTEGER,
snMacFilterPortAccessFilters
OCTET STRING,
snMacFilterPortAccessRowStatus
INTEGER
}
snMacFilterPortAccessPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..3900)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port index.
For FastIron/NetIron products, port index value is from 1 to 42
For BigIron products, port index is an encoded number:
The bit 0 to bit 7: port number.
The bit 8 to bit 11: slot number.
For virtual router interface, slot number is 15,
port number is the virtual router port from 1 to 60.
Therefore, port index value for BigIron is from 257 to 3900."
::= { snMacFilterPortAccessEntry 1 }
snMacFilterPortAccessFilters OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"1st octet correspond to 1st filter
number and so on."
::= { snMacFilterPortAccessEntry 2 }
snMacFilterPortAccessRowStatus OBJECT-TYPE
SYNTAX INTEGER {
invalid(1),
valid(2),
delete(3),
create(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to create and
delete row in the table and control
if they are used. The values
that can be written are:
delete(3)...deletes the row
create(4)...creates a new row
If the row exists, then a SET with
value of create(4) returns error
'badValue'. Deleted rows go away
immediately. The following values
can be returned on reads:
noSuch(0)...no such row
invalid(1)...Setting it to 'invalid' has the effect of
rendering it inoperative..
valid(2)....the row exists and is valid"
::= { snMacFilterPortAccessEntry 3 }
-- NTP general group
snNTPGeneral OBJECT IDENTIFIER ::= { snNTP 1 }
snNTPPollInterval OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interval specifies how often to poll the NTP server.
Each unit is one second."
DEFVAL { 1800 }
::= { snNTPGeneral 1 }
snNTPTimeZone OBJECT-TYPE
SYNTAX INTEGER {
alaska(0),
aleutian(1),
arizona(2),
central(3),
eastIndiana(4),
eastern(5),
hawaii(6),
michigan(7),
mountain(8),
pacific(9),
samoa(10),
gmtPlus12(11),
gmtPlus11(12),
gmtPlus10(13),
gmtPlus9(14),
gmtPlus8(15),
gmtPlus7(16),
gmtPlus6(17),
gmtPlus5(18),
gmtPlus4(19),
gmtPlus3(20),
gmtPlus2(21),
gmtPlus1(22),
gmt(23),
gmtMinus1(24),
gmtMinus2(25),
gmtMinus3(26),
gmtMinus4(27),
gmtMinus5(28),
gmtMinus6(29),
gmtMinus7(30),
gmtMinus8(31),
gmtMinus9(32),
gmtMinus10(33),
gmtMinus11(34),
gmtMinus12(35) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Time zone."
DEFVAL { gmt }
::= { snNTPGeneral 2 }
snNTPSummerTimeEnable OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled (1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/Disable daylight saving time. This enables daylight
saving time for time/date starting 02:00:00 of first Sunday
in April and ending 02:00:00 of last Sunday in October every
year."
DEFVAL { disabled }
::= { snNTPGeneral 3 }
snNTPSystemClock OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System clock, in the following format:
octet 0: seconds after the minute [0-60]
octet 1: minutes after the hour [0-59]
octet 2: hours since midnight [0-23]
octet 3: day of the month [1-31]
octet 4: months since January [0-11]
octet 5: years since 1900
octet 6: days since Sunday [0-6]
Setting this object requires valid value in octets 0 to 5,
and zero in octet 6. System clock can be disabled by setting
zero to all octets."
::= { snNTPGeneral 4 }
snNTPSync OBJECT-TYPE
SYNTAX INTEGER { other(1), synchronize(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Initiate time synchronization to the NTP servers.
For set operation, only 'synchronize(2)' is accepted.
For get operation, always return 'other(1)'."
::= { snNTPGeneral 5 }
-- NTP server table
snNTPServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnNTPServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NTP (Network Time Protocol) server table."
::= { snNTP 2 }
snNTPServerEntry OBJECT-TYPE
SYNTAX SnNTPServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the NTP server table."
INDEX { snNTPServerIp }
::= { snNTPServerTable 1 }
SnNTPServerEntry ::= SEQUENCE {
snNTPServerIp
IpAddress,
snNTPServerVersion
INTEGER,
snNTPServerRowStatus
INTEGER
}
snNTPServerIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NTP server IP address."
::= { snNTPServerEntry 1 }
snNTPServerVersion OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NTP server version."
DEFVAL { 1 }
::= { snNTPServerEntry 2 }
snNTPServerRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To create or delete a NTP server table entry."
::= { snNTPServerEntry 3 }
-- Radius general group
snRadiusGeneral OBJECT IDENTIFIER ::= { snRadius 1 }
snRadiusSNMPAccess OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicate whether Radius group MIB obejcts can be
accessed by SNMP manager. If value is disabled,
all Radius group MIB objects return 'general error'."
DEFVAL { disabled }
::= { snRadiusGeneral 1 }
snRadiusEnableTelnetAuth OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/Disable telnet authentication specified
by 'snRadiusLoginMethod'."
DEFVAL { disabled }
::= { snRadiusGeneral 2 }
snRadiusRetransmit OBJECT-TYPE
SYNTAX INTEGER (0..5)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of authentication query retransmissions
to the Radius server."
DEFVAL { 3 }
::= { snRadiusGeneral 3 }
snRadiusTimeOut OBJECT-TYPE
SYNTAX INTEGER (1..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interval specifies how long to wait for authentication
reply from the Radius server, each unit is one second."
DEFVAL { 3 }
::= { snRadiusGeneral 4 }
snRadiusDeadTime OBJECT-TYPE
SYNTAX INTEGER (1..5)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interval specifies Radius server dead time,
each unit is one minute."
DEFVAL { 3 }
::= { snRadiusGeneral 5 }
snRadiusKey OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Authentication key displayed as encrypted text."
::= { snRadiusGeneral 6 }
snRadiusLoginMethod OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..7))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A sequence of authentication methods. Each octet represents
a method to authenticate the user login process. Each octet
has the following enumeration value:
enable(1) - authenticate by command line interface
enable password
radius(2) - authenticate by requesting radius server
local(3) - authenticate by local user account table
line(4) - authenticate by telnet password
tacplus(5) - authenticate by requesting tacplus server
none(6) - do not authenticate
tacacs(7) - authenticate by requesting tacacs server
Setting a zero length octet string invalidates all
previous authentication methods."
::= { snRadiusGeneral 7 }
snRadiusEnableMethod OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..7))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A sequence of authentication methods. Each octet represents
a method to authenticate the user entering priviledge mode
of the command line interface. Each octet has the following
enumeration value:
enable(1) - authenticate by command line interface
enable password
radius(2) - authenticate by requesting radius server
local(3) - authenticate by local user account table
line(4) - authenticate by telnet password
tacplus(5) - authenticate by requesting tacplus server
none(6) - do not authenticate
tacacs(7) - authenticate by requesting tacacs server
Setting a zero length octet string invalidates all
previous authentication methods."
::= { snRadiusGeneral 8 }
snRadiusWebServerMethod OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..7))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A sequence of authentication methods. Each octet represents
a method to authenticate the user accessing the web-server.
Each octet has the following enumeration value:
enable(1) - authenticate by command line interface
enable password
radius(2) - authenticate by requesting radius server
local(3) - authenticate by local user account table
line(4) - authenticate by telnet password
tacplus(5) - authenticate by requesting tacplus server
none(6) - do not authenticate
tacacs(7) - authenticate by requesting tacacs server
Setting a zero length octet string invalidates all
previous authentication methods."
::= { snRadiusGeneral 9 }
snRadiusSNMPServerMethod OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..7))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A sequence of authentication methods. Each octet represents
a method to authenticate the user accessing the snmp-server.
Each octet has the following enumeration value:
enable(1) - authenticate by command line interface
enable password
radius(2) - authenticate by requesting radius server
local(3) - authenticate by local user account table
line(4) - authenticate by telnet password
tacplus(5) - authenticate by requesting tacplus server
none(6) - do not authenticate
tacacs(7) - authenticate by requesting tacacs server
Setting a zero length octet string invalidates all
previous authentication methods."
::= { snRadiusGeneral 10 }
-- Radius server table
snRadiusServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnRadiusServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Radius server table."
::= { snRadius 2 }
snRadiusServerEntry OBJECT-TYPE
SYNTAX SnRadiusServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Radius server table."
INDEX { snRadiusServerIp }
::= { snRadiusServerTable 1 }
SnRadiusServerEntry ::= SEQUENCE {
snRadiusServerIp
IpAddress,
snRadiusServerAuthPort
INTEGER,
snRadiusServerAcctPort
INTEGER,
snRadiusServerRowStatus
INTEGER,
snRadiusServerRowKey
DisplayString,
snRadiusServerUsage
INTEGER
}
snRadiusServerIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Radius server IP address."
::= { snRadiusServerEntry 1 }
snRadiusServerAuthPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Authentication UDP port number."
DEFVAL { 1645 }
::= { snRadiusServerEntry 2 }
snRadiusServerAcctPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Account UDP port number."
DEFVAL { 1646 }
::= { snRadiusServerEntry 3 }
snRadiusServerRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To create or delete a Radius server table entry."
::= { snRadiusServerEntry 4 }
snRadiusServerRowKey OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Authentication key displayed as encrypted text."
::= { snRadiusServerEntry 5 }
snRadiusServerUsage OBJECT-TYPE
SYNTAX INTEGER {
default(1),
authentication-only(2),
authorization-only(3),
accounting-only(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To allow this server to be dedicated for a particular AAA activity."
::= { snRadiusServerEntry 6 }
--- Tacacs General MIBs
snTacacsGeneral OBJECT IDENTIFIER ::= { snTacacs 1 }
snTacacsRetransmit OBJECT-TYPE
SYNTAX INTEGER (0..5)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of authentication query retransmissions
to the Tacacs server."
DEFVAL { 3 }
::= { snTacacsGeneral 1 }
snTacacsTimeOut OBJECT-TYPE
SYNTAX INTEGER (1..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interval specifies how long to wait for authentication
reply from the Tacacs server, each unit is one second."
DEFVAL { 3 }
::= { snTacacsGeneral 2 }
snTacacsDeadTime OBJECT-TYPE
SYNTAX INTEGER (1..5)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interval specifies Tacacs server dead time,
each unit is one minute."
DEFVAL { 3 }
::= { snTacacsGeneral 3 }
snTacacsKey OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Authentication key displayed as encrypted text."
::= { snTacacsGeneral 4 }
snTacacsSNMPAccess OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicate whether Tacacs group MIB obejcts can be
accessed by SNMP manager. If value is disabled,
all Tacacs group MIB objects return 'general error'."
DEFVAL { disabled }
::= { snTacacsGeneral 5 }
-- Tacacs server table
snTacacsServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnTacacsServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Tacacs server table."
::= { snTacacs 2 }
snTacacsServerEntry OBJECT-TYPE
SYNTAX SnTacacsServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Tacacs server table."
INDEX { snTacacsServerIp }
::= { snTacacsServerTable 1 }
SnTacacsServerEntry ::= SEQUENCE {
snTacacsServerIp
IpAddress,
snTacacsServerAuthPort
INTEGER,
snTacacsServerRowStatus
INTEGER,
snTacacsServerRowKey
DisplayString,
snTacacsServerUsage
INTEGER
}
snTacacsServerIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Tacacs server IP address."
::= { snTacacsServerEntry 1 }
snTacacsServerAuthPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Authentication UDP port number."
DEFVAL { 49 }
::= { snTacacsServerEntry 2 }
snTacacsServerRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To create or delete a Tacacs server table entry."
::= { snTacacsServerEntry 3 }
snTacacsServerRowKey OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Authentication key displayed as encrypted text."
::= { snTacacsServerEntry 4 }
snTacacsServerUsage OBJECT-TYPE
SYNTAX INTEGER {
default(1),
authentication-only(2),
authorization-only(3),
accounting-only(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To allow this server to be dedicated for a particular AAA activity."
::= { snTacacsServerEntry 5 }
-- QOS Profile Group
snQosProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnQosProfileEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table contains the configuration of qos profile
groups."
::= { snQos 1 }
snQosProfileEntry OBJECT-TYPE
SYNTAX SnQosProfileEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of the snQosProfileTable."
INDEX {snQosProfileIndex}
::= { snQosProfileTable 1 }
SnQosProfileEntry ::= SEQUENCE {
snQosProfileIndex
INTEGER,
snQosProfileName
DisplayString,
snQosProfileRequestedBandwidth
INTEGER,
snQosProfileCalculatedBandwidth
INTEGER
}
snQosProfileIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The table index of QOS Profile."
::= { snQosProfileEntry 1 }
snQosProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Qos Profile Name string."
::= { snQosProfileEntry 2 }
snQosProfileRequestedBandwidth OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Qos Profile Requested Bandwidth."
::= { snQosProfileEntry 3 }
snQosProfileCalculatedBandwidth OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Qos Profile Calculated Bandwidth."
::= { snQosProfileEntry 4 }
-- QOS Bind Group
snQosBindTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnQosBindEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table contains the configuration of 802.1p to qos profile
binding groups."
::= { snQos 2 }
snQosBindEntry OBJECT-TYPE
SYNTAX SnQosBindEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of the snQosBindTable."
INDEX {snQosBindIndex}
::= { snQosBindTable 1 }
SnQosBindEntry ::= SEQUENCE {
snQosBindIndex
INTEGER,
snQosBindPriority
INTEGER,
snQosBindProfileIndex
INTEGER
}
snQosBindIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The table index of QOS Bind."
::= { snQosBindEntry 1 }
snQosBindPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QOS bind priority."
::= { snQosBindEntry 2 }
snQosBindProfileIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QOS Bind Profile Index. This is pointer to the
index of snQosProfile Table."
::= { snQosBindEntry 3 }
-- AAA Mib
snAuthentication OBJECT IDENTIFIER ::= { snAAA 1 }
snAuthorization OBJECT IDENTIFIER ::= { snAAA 2 }
snAccounting OBJECT IDENTIFIER ::= { snAAA 3 }
snAuthorizationCommandMethods OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A sequence of authorization methods. Each octet represents
a method to authorize the user command. Each octet
has the following value:
radius(2) - authorize by requesting radius server
tacplus(5) - authorize by requesting tacplus server
none(6) - skip authorization
Setting a zero length octet string invalidates all
previous authorization methods."
::= { snAuthorization 1 }
snAuthorizationCommandLevel OBJECT-TYPE
SYNTAX INTEGER {
level0(0),
level4(4),
level5(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Commands, which are equal to and less than the specified
command level here needs to be authorized. Possible enumeration
values:
0 - Privilege level 0
4 - Privilege level 4
5 - Privilege level 5."
::= { snAuthorization 2 }
snAuthorizationExec OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A sequence of exec authorization methods. Each octet represents
a method for telnet or SSH login authorization. Each octet
has the following enumeration value:
radius(2) - send exec authorization request to radius server
tacplus(5) - send exec authorization request to tacplus server
none(6) - no exec authorization
Setting a zero length octet string invalidates all
authorization methods."
::= { snAuthorization 3 }
snAccountingCommandMethods OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A sequence of accounting methods. Each octet represents
a method to account for the user command. Each octet
has the following enumeration value:
radius(2) - send accounting info to radius server
tacplus(5) - send accounting info to tacplus server
none(6) - skip accounting
Setting a zero length octet string invalidates all
previous accounting methods."
::= { snAccounting 1 }
snAccountingCommandLevel OBJECT-TYPE
SYNTAX INTEGER {
level0(0),
level4(4),
level5(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Commands, which are equal to and less than the specified
command level here will be accounted. Possible enumeration
values:
level0 - Privilege level 0
level4 - Privilege level 4
level5 - Privilege level 5."
::= { snAccounting 2 }
snAccountingExec OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A sequence of accounting methods. Each octet represents
a method for telnet or SSH login accounting. Each octet
has the following enumeration value:
radius(2) - send accounting info to radius server
tacplus(5) - send accounting info to tacplus server
none(6) - skip accounting
Setting a zero length octet string invalidates all
previous accounting methods."
::= { snAccounting 3 }
snAccountingSystem OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A sequence of accounting methods. Each octet represents
a method to account for the system related events. Each octet
has the following enumeration value:
radius(2) - send accounting info to radius server
tacplus(5) - send accounting info to tacplus server
none(6) - skip accounting
Setting a zero length octet string invalidates all
previous accounting methods."
::= { snAccounting 4 }
-- NetFlow Mib
snNetFlowGlb OBJECT IDENTIFIER ::= { snNetFlow 1 }
snNetFlowGblEnable OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable NetFlow export operation."
DEFVAL { disabled }
::= { snNetFlowGlb 1 }
snNetFlowGblVersion OBJECT-TYPE
SYNTAX INTEGER { version1 (1), version5 (5) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NetFlow export version."
DEFVAL { version5 }
::= { snNetFlowGlb 2 }
snNetFlowGblProtocolDisable OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"bit 0 - other, disable all protocols export except UDP and TCP
bit 1 - tcp, disable TCP protocol export
bit 2 - udp, disable UDP protocol export"
DEFVAL { 0 }
::= { snNetFlowGlb 3 }
snNetFlowGblActiveTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum time an active flow can be in the NetFlow cache (minutes: 1..60)"
DEFVAL { 60 }
::= { snNetFlowGlb 4 }
snNetFlowGblInactiveTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum time an inactive flow can be in the NetFlow cache (seconds: 10..600)"
DEFVAL { 60 }
::= { snNetFlowGlb 5 }
-- NetFlow Collector Table
snNetFlowCollectorTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnNetFlowCollectorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of each NetFlow collector information."
::= { snNetFlow 2 }
snNetFlowCollectorEntry OBJECT-TYPE
SYNTAX SnNetFlowCollectorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the NetFlow collector table."
INDEX { snNetFlowCollectorIndex }
::= { snNetFlowCollectorTable 1 }
SnNetFlowCollectorEntry ::= SEQUENCE {
snNetFlowCollectorIndex
INTEGER,
snNetFlowCollectorIp
IpAddress,
snNetFlowCollectorUdpPort
INTEGER,
snNetFlowCollectorSourceInterface
INTEGER,
snNetFlowCollectorRowStatus
INTEGER
}
snNetFlowCollectorIndex OBJECT-TYPE
SYNTAX INTEGER (1..10)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the NetFlow collector table."
::= { snNetFlowCollectorEntry 1 }
snNetFlowCollectorIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The NetFlow collector ip address."
::= { snNetFlowCollectorEntry 2 }
snNetFlowCollectorUdpPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The NetFlow collector UDP port number."
::= { snNetFlowCollectorEntry 3 }
snNetFlowCollectorSourceInterface OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The ifIndex value to specify source port to
export NetFlow packet. Value 0 to indicate
default outgoing port."
::= { snNetFlowCollectorEntry 4 }
snNetFlowCollectorRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To create or delete a NetFlow collector table entry."
::= { snNetFlowCollectorEntry 5 }
-- NetFlow Aggregation Table
snNetFlowAggregationTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnNetFlowAggregationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of each NetFlow aggregation scheme information."
::= { snNetFlow 3 }
snNetFlowAggregationEntry OBJECT-TYPE
SYNTAX SnNetFlowAggregationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the NetFlow Aggregation table."
INDEX { snNetFlowAggregationIndex }
::= { snNetFlowAggregationTable 1 }
SnNetFlowAggregationEntry ::= SEQUENCE {
snNetFlowAggregationIndex
INTEGER,
snNetFlowAggregationIp
IpAddress,
snNetFlowAggregationUdpPort
INTEGER,
snNetFlowAggregationSourceInterface
INTEGER,
snNetFlowAggregationNumberOfCacheEntries
INTEGER,
snNetFlowAggregationActiveTimeout
INTEGER,
snNetFlowAggregationInactiveTimeout
INTEGER,
snNetFlowAggregationEnable
INTEGER,
snNetFlowAggregationRowStatus
INTEGER
}
snNetFlowAggregationIndex OBJECT-TYPE
SYNTAX INTEGER { as (1), protocolPort (2), destPrefix (3),
sourcePrefix (4), prefix (5) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Aggregation scheme ID"
::= { snNetFlowAggregationEntry 1 }
snNetFlowAggregationIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The NetFlow aggregation collector ip address."
::= { snNetFlowAggregationEntry 2 }
snNetFlowAggregationUdpPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The NetFlow aggregation collector UDP port number."
::= { snNetFlowAggregationEntry 3 }
snNetFlowAggregationSourceInterface OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The ifIndex value to specify source port to
export NetFlow aggregation packet.
Value 0 to indicate default outgoing port."
::= { snNetFlowAggregationEntry 4 }
snNetFlowAggregationNumberOfCacheEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of cache entries for aggregation scheme"
::= { snNetFlowAggregationEntry 5 }
snNetFlowAggregationActiveTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum time an active flow can be in
the aggregation cache"
::= { snNetFlowAggregationEntry 6 }
snNetFlowAggregationInactiveTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum time an inactive flow can be in
the aggregation cache"
::= { snNetFlowAggregationEntry 7 }
snNetFlowAggregationEnable OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable NetFlow aggregation
for this aggregation scheme."
DEFVAL { disabled }
::= { snNetFlowAggregationEntry 8 }
snNetFlowAggregationRowStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
valid(2),
delete(3),
create(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To create or delete a NetFlow collector table entry."
::= { snNetFlowAggregationEntry 9 }
-- NetFlow Interface Table
-- Table containing information about the switching
-- type in every interface.
snNetFlowIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnNetFlowIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of interface entries. The number of entries
is given by the value of ifNumber."
::= { snNetFlow 4 }
snNetFlowIfEntry OBJECT-TYPE
SYNTAX SnNetFlowIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entry containing the type of switching performed
on that interface."
INDEX { snNetFlowIfIndex }
::= { snNetFlowIfTable 1 }
SnNetFlowIfEntry ::= SEQUENCE {
snNetFlowIfIndex
INTEGER,
snNetFlowIfFlowSwitching
INTEGER
}
snNetFlowIfIndex OBJECT-TYPE
SYNTAX INTEGER (1..65536)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value, greater than zero, for each
interface. It is recommended that values are assigned
contiguously starting from 1. The value for each
interface sub-layer must remain constant at least from
one re-initialization of the entity's network
management system to the next re-initialization."
::= { snNetFlowIfEntry 1 }
snNetFlowIfFlowSwitching OBJECT-TYPE
SYNTAX INTEGER { disabled (0), enabled (1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To enable/disable flow switching in a particular
interface:
disable (0) - no flow switching
enable (1) - flow switching"
::= { snNetFlowIfEntry 2 }
-- sFlow Collector Table.
snSFlowGlb OBJECT IDENTIFIER ::= { snSFlow 1 }
snSflowCollectorTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnSflowCollectorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of all but first sFlow collectors. The first collector can be configured
using sFlowTable in RFC 3176. The RFC cannot be used to configure more
than one sFlow collectors. This table has been created to fill this gap."
::= { snSFlow 2 }
snSflowCollectorEntry OBJECT-TYPE
SYNTAX SnSflowCollectorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A row in the sFlow collector table."
INDEX { snSflowCollectorIndex }
::= { snSflowCollectorTable 1 }
SnSflowCollectorEntry ::= SEQUENCE {
snSflowCollectorIndex
INTEGER,
snSflowCollectorIP
IpAddress,
snSflowCollectorUDPPort
INTEGER,
snSflowCollectorRowStatus
INTEGER
}
snSflowCollectorIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to the sFlow collector table."
::= { snSflowCollectorEntry 1 }
snSflowCollectorIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The sFlow collector ip address."
::= { snSflowCollectorEntry 2 }
snSflowCollectorUDPPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The sFlow collector UDP port number."
::= { snSflowCollectorEntry 3 }
snSflowCollectorRowStatus OBJECT-TYPE
SYNTAX INTEGER {
noSuch(0),
other(1),
valid(2),
delete(3),
create(4),
modify(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To create, update or delete a SFlow collector table entry.
If the row exists, then a SET with
value of create(4) returns error
'badValue'. Deleted rows go away
immediately. The following values
can be returned on reads:
noSuch(0)...no such row
other(1)....some other case
valid(2)....the row exists and is valid"
::= { snSflowCollectorEntry 4 }
snFdpMIBObjects OBJECT IDENTIFIER ::= { snFDP 1 }
snFdpInterface OBJECT IDENTIFIER ::= { snFdpMIBObjects 1 }
snFdpCache OBJECT IDENTIFIER ::= { snFdpMIBObjects 2 }
snFdpGlobal OBJECT IDENTIFIER ::= { snFdpMIBObjects 3 }
snFdpCachedAddr OBJECT IDENTIFIER ::= { snFdpMIBObjects 4 }
--
-- FDP Interface Group
--
snFdpInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF FdpInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Status of FDP on the device's interfaces."
::= { snFdpInterface 1 }
snFdpInterfaceEntry OBJECT-TYPE
SYNTAX FdpInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the snFdpInterfaceTable,
having the status of FDP on an interface."
INDEX { snFdpInterfaceIfIndex }
::= { snFdpInterfaceTable 1 }
FdpInterfaceEntry ::= SEQUENCE {
snFdpInterfaceIfIndex INTEGER,
snFdpInterfaceFdpEnable INTEGER,
snFdpInterfaceCdpEnable INTEGER
}
snFdpInterfaceIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ifIndex value of the local interface."
::= { snFdpInterfaceEntry 1 }
snFdpInterfaceFdpEnable OBJECT-TYPE
SYNTAX INTEGER { false(0), true(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The flag, whether the Foundry Discovery Protocol
is currently running on this interface. It has no
effect when FDP is disabled (snFdpGlobalRun = FALSE)."
DEFVAL { true }
::= { snFdpInterfaceEntry 2 }
snFdpInterfaceCdpEnable OBJECT-TYPE
SYNTAX INTEGER { false(0), true(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The flag, whether the Cisco Discovery Protocol
is currently running on this interface. It has no
effect when CDP is disabled (snCdpGlobalRun = FALSE)."
DEFVAL { true }
::= { snFdpInterfaceEntry 3 }
--
-- FDP Cache Table
--
snFdpCacheTable OBJECT-TYPE
SYNTAX SEQUENCE OF FdpCacheEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table for the cached information obtained
via receiving FDP/CDP messages."
::= { snFdpCache 1 }
snFdpCacheEntry OBJECT-TYPE
SYNTAX FdpCacheEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the snFdpCacheTable, having the information
received via FDP/CDP on one interface from one device.
Entries appear when a FDP/CDP advertisement is received
from a neighbor device.
Entries disappear when FDP/CDP is disabled on the interface, or globally."
INDEX { snFdpCacheIfIndex, snFdpCacheDeviceIndex }
::= { snFdpCacheTable 1 }
FdpCacheEntry ::= SEQUENCE {
snFdpCacheIfIndex INTEGER,
snFdpCacheDeviceIndex INTEGER,
snFdpCacheDeviceId DisplayString,
snFdpCacheAddressType INTEGER,
snFdpCacheAddress OCTET STRING,
snFdpCacheVersion DisplayString,
snFdpCacheDevicePort DisplayString,
snFdpCachePlatform DisplayString,
snFdpCacheCapabilities DisplayString,
snFdpCacheVendorId INTEGER,
snFdpCacheIsAggregateVlan INTEGER,
snFdpCacheTagType INTEGER,
snFdpCachePortVlanMask OCTET STRING,
snFdpCachePortTagMode INTEGER,
snFdpCacheDefaultTrafficeVlanIdForDualMode INTEGER
}
snFdpCacheIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ifIndex value of the local interface."
::= { snFdpCacheEntry 1 }
snFdpCacheDeviceIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Identification of a device, which sent FDP/CDP messages"
::= { snFdpCacheEntry 2 }
snFdpCacheDeviceId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Device-ID string as reported in the most recent FDP/CDP
message. The zero-length string indicates no Device-ID
field (TLV) was reported in the most recent FDP/CDP
message."
::= { snFdpCacheEntry 3 }
snFdpCacheAddressType OBJECT-TYPE
SYNTAX INTEGER { ip(1), ipx(2), appletalk(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An indication of the type of address contained in the
corresponding instance of snFdpCacheAddress."
::= { snFdpCacheEntry 4 }
snFdpCacheAddress OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The (first) network-layer address of the device
as reported in the most recent FDP/CDP message
in the following format:
IP address: 4 octets, ip(1)
IPX address: 10 octets, ipx(2)
First 4-octet as the network number
Second 6-octet as the host number
Appletalk address: 3 octets, appletalk(3)
First 2-octet as the network number
Second 1-octet as the host number"
::= { snFdpCacheEntry 5 }
snFdpCacheVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Version string as reported in the most recent FDP/CDP message. "
::= { snFdpCacheEntry 6 }
snFdpCacheDevicePort OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Port-ID string as reported in the most recent FDP/CDP
message. This will typically be the value of the ifName
object (e.g., Ethernet0). The zero-length string
indicates no Port-ID field (TLV) was reported in the
most recent FDP/CDP message."
::= { snFdpCacheEntry 7 }
snFdpCachePlatform OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Device's Hardware Platform as reported in the most
recent FDP/CDP message. The zero-length string indicates
that no Platform field (TLV) was reported in the most
recent FDP/CDP message."
::= { snFdpCacheEntry 8 }
snFdpCacheCapabilities OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Device's Functional Capabilities as reported in the
most recent FDP/CDP message. "
::= { snFdpCacheEntry 9 }
snFdpCacheVendorId OBJECT-TYPE
SYNTAX INTEGER { fdp(1), cdp(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the entry received by either FDP or CDP."
::= { snFdpCacheEntry 10 }
snFdpCacheIsAggregateVlan OBJECT-TYPE
SYNTAX INTEGER { false(0), true(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Neighbor device is in aggregated-vlan."
::= { snFdpCacheEntry 11 }
snFdpCacheTagType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Neighbor device tag-type."
::= { snFdpCacheEntry 12 }
snFdpCachePortVlanMask OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Neighbor device port VLAN masks in 512-byte octet string."
::= { snFdpCacheEntry 13 }
snFdpCachePortTagMode OBJECT-TYPE
SYNTAX INTEGER { untagged(1), tagged(2), dual(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Neighbor device port tag mode"
::= { snFdpCacheEntry 14 }
snFdpCacheDefaultTrafficeVlanIdForDualMode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Default traffic vlan id for neighbor device dual-mode port"
::= { snFdpCacheEntry 15 }
--
-- FDP Global Group
--
snFdpGlobalRun OBJECT-TYPE
SYNTAX INTEGER { false(0), true(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The flag, whether the Foundry Discovery Protocol
is currently running. FDP entries in snFdpCacheTable are
deleted when FDP is disabled."
DEFVAL { false }
::= { snFdpGlobal 1 }
snFdpGlobalMessageInterval OBJECT-TYPE
SYNTAX INTEGER (5..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The interval at which FDP messages are to be generated.
The default value is 60 seconds."
DEFVAL { 60 }
::= { snFdpGlobal 2 }
snFdpGlobalHoldTime OBJECT-TYPE
SYNTAX INTEGER (10..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time for the receiving device holds FDP message.
The default value is 180 seconds."
DEFVAL { 180 }
::= { snFdpGlobal 3 }
snFdpGlobalCdpRun OBJECT-TYPE
SYNTAX INTEGER { false(0), true(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"An indication of whether the Cisco Discovery Protocol
is currently running. CDP entries in snFdpCacheTable are
deleted when CDP is disabled."
DEFVAL { false }
::= { snFdpGlobal 4 }
--
-- FDP Cached Address Entry Table
--
snFdpCachedAddressTable OBJECT-TYPE
SYNTAX SEQUENCE OF FdpCachedAddressEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Cached address table from receiving FDP/CDP messages."
::= { snFdpCachedAddr 1 }
snFdpCachedAddressEntry OBJECT-TYPE
SYNTAX FdpCachedAddressEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry (conceptual row) in the snFdpCacheAddressTable,
containing one cached address from FDP/CDP messages."
INDEX { snFdpCachedAddrIfIndex, snFdpCachedAddrDeviceIndex, snFdpCachedAddrDeviceAddrEntryIndex }
::= { snFdpCachedAddressTable 1 }
FdpCachedAddressEntry ::= SEQUENCE {
snFdpCachedAddrIfIndex INTEGER,
snFdpCachedAddrDeviceIndex INTEGER,
snFdpCachedAddrDeviceAddrEntryIndex INTEGER,
snFdpCachedAddrType INTEGER,
snFdpCachedAddrValue OCTET STRING
}
snFdpCachedAddrIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The ifIndex value of the local interface."
::= { snFdpCachedAddressEntry 1 }
snFdpCachedAddrDeviceIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A unique vlaue for each device from which FDP/CDP messages
are being received."
::= { snFdpCachedAddressEntry 2 }
snFdpCachedAddrDeviceAddrEntryIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A unique vlaue for address entry in device from which FDP/CDP messages
are being received."
::= { snFdpCachedAddressEntry 3 }
snFdpCachedAddrType OBJECT-TYPE
SYNTAX INTEGER { ip(1), ipx(2), appletalk(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An indication of the type of address contained in the
corresponding instance of snFdpCacheAddrValue."
::= { snFdpCachedAddressEntry 4 }
snFdpCachedAddrValue OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The network-layer address of the device
SNMP-agent as reported in the most recent FDP/CDP message
in the following format:
IP address: 4 octets, ip(1)
IPX address: 10 octets, ipx(2)
First 4-octet as the network number
Second 6-octet as the host number
Appletalk address: 3 octets, appletalk(3)
First 2-octet as the network number
Second 1-octet as the host number"
::= { snFdpCachedAddressEntry 5 }
END