mibs/MIBS/huawei/HUAWEI-SLOG-EUDM-MIB
2023-12-05 12:25:34 +01:00

234 lines
7.0 KiB
Plaintext

-- =================================================================
-- Copyright (C) 2003 by HUAWEI TECHNOLOGIES. All rights reserved
--
-- Description: HUAWEI-SLOG-EUDM-MIB
-- Reference:
-- Version: V1.0
-- History:
-- yangyinzhu,2003-03-18,<contents>
-- =================================================================
HUAWEI-SLOG-EUDM-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-GROUP
FROM SNMPv2-CONF
IpAddress, Integer32, OBJECT-TYPE, MODULE-IDENTITY
FROM SNMPv2-SMI
TruthValue, TEXTUAL-CONVENTION
FROM SNMPv2-TC
hwDatacomm
FROM HUAWEI-MIB;
hwSLOGEudm MODULE-IDENTITY
LAST-UPDATED "200304081633Z" -- April 08, 2003 at 16:33 GMT
ORGANIZATION
"Huawei Technologies co.,Ltd."
CONTACT-INFO
"
R&D BeiJing, Huawei Technologies co.,Ltd.
Huawei Bld.,NO.3 Xinxi Rd.,
Shang-Di Information Industry Base,
Hai-Dian District Beijing P.R. China
Zip:100085
Http://www.huawei.com
E-mail:support@huawei.com
"
DESCRIPTION
"
V1.00
The HUAWEI-SLOG-EUDM-MIB contains objects to manage the security
log for firewall product.
"
::= { hwSLOG 2 }
--
-- Textual conventions
--
FlowLogType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Description."
SYNTAX INTEGER
{
flowLogSysLog(1),
flowLogExport(2)
}
--
-- Node definitions
--
-- 1.3.6.1.4.1.2011.5.25.16
hwSLOG OBJECT IDENTIFIER ::= { hwDatacomm 16 }
-- 1.3.6.1.4.1.2011.5.25.16.2.1
hwSLogEudmGlobalCfg OBJECT IDENTIFIER ::= { hwSLOGEudm 1 }
-- 1.3.6.1.4.1.2011.5.25.16.2.1.1
hwSLogEudmAttackLogInterval OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
The interval for sending log of attack event, the unit is second."
::= { hwSLogEudmGlobalCfg 1 }
-- 1.3.6.1.4.1.2011.5.25.16.2.1.2
hwSLogEudmFlowLogInterval OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval for sending flow log, the unit is second."
::= { hwSLogEudmGlobalCfg 2 }
-- 1.3.6.1.4.1.2011.5.25.16.2.1.3
hwSLogEudmStreamLogInterval OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval for sending log of statistics, the unit is second."
::= { hwSLogEudmGlobalCfg 3 }
-- 1.3.6.1.4.1.2011.5.25.16.2.1.4
hwSLogEudmFlowLogMode OBJECT-TYPE
SYNTAX FlowLogType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The sending mode of flow log, can be SysLog or Export."
DEFVAL { flowLogSysLog }
::= { hwSLogEudmGlobalCfg 4 }
-- 1.3.6.1.4.1.2011.5.25.16.2.1.5
hwSLogEudmServerIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of log server."
DEFVAL { 00000000 }
::= { hwSLogEudmGlobalCfg 5 }
-- 1.3.6.1.4.1.2011.5.25.16.2.1.6
hwSLogEudmServerPort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port of log server."
::= { hwSLogEudmGlobalCfg 6 }
-- 1.3.6.1.4.1.2011.5.25.16.2.2
hwSLogInterZoneEnableCfg OBJECT IDENTIFIER ::= { hwSLOGEudm 2 }
-- 1.3.6.1.4.1.2011.5.25.16.2.2.1
hwSLogEudmFlowLogEnableTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwSLogEudmFlowLogEnableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description"
::= { hwSLogInterZoneEnableCfg 1 }
-- 1.3.6.1.4.1.2011.5.25.16.2.2.1.1
hwSLogEudmFlowLogEnableEntry OBJECT-TYPE
SYNTAX HwSLogEudmFlowLogEnableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each inter-zone must have an entry"
INDEX { hwSLogFlowEnableZoneID1, hwSLogFlowEnableZoneID2 }
::= { hwSLogEudmFlowLogEnableTable 1 }
HwSLogEudmFlowLogEnableEntry ::=
SEQUENCE {
hwSLogFlowEnableZoneID1
Integer32,
hwSLogFlowEnableZoneID2
Integer32,
hwSLogEudmFlowEnableFlag
TruthValue,
hwSLogEudmEnableHostAcl
Integer32
}
-- 1.3.6.1.4.1.2011.5.25.16.2.2.1.1.1
hwSLogFlowEnableZoneID1 OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ID of first zone that compose the inter-zone."
::= { hwSLogEudmFlowLogEnableEntry 1 }
-- 1.3.6.1.4.1.2011.5.25.16.2.2.1.1.2
hwSLogFlowEnableZoneID2 OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ID of second zone that compose the inter-zone."
::= { hwSLogEudmFlowLogEnableEntry 2 }
-- 1.3.6.1.4.1.2011.5.25.16.2.2.1.1.3
hwSLogEudmFlowEnableFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status indicate whether the security log is enabled in this interzone."
::= { hwSLogEudmFlowLogEnableEntry 3 }
-- 1.3.6.1.4.1.2011.5.25.16.2.2.1.1.4
hwSLogEudmEnableHostAcl OBJECT-TYPE
SYNTAX Integer32 (0 | 2000..3999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The acl number indicate the data flow which will be logged."
::= { hwSLogEudmFlowLogEnableEntry 4 }
-- 1.3.6.1.4.1.2011.5.25.16.2.3
hwSLOGEudmConformance OBJECT IDENTIFIER ::= { hwSLOGEudm 3 }
-- 1.3.6.1.4.1.2011.5.25.16.2.3.1
hwSLOGEudmCompliance OBJECT IDENTIFIER ::= { hwSLOGEudmConformance 1 }
-- 1.3.6.1.4.1.2011.5.25.16.2.3.2
hwSLOGEudmMibGroups OBJECT IDENTIFIER ::= { hwSLOGEudmConformance 2 }
-- 1.3.6.1.4.1.2011.5.25.16.2.3.2.1
hwSLOGEudmGlobalCfgGroup OBJECT-GROUP
OBJECTS {
hwSLogEudmAttackLogInterval,
hwSLogEudmStreamLogInterval,
hwSLogEudmFlowLogMode,
hwSLogEudmFlowLogInterval,
hwSLogEudmServerIP,
hwSLogEudmServerPort }
STATUS current
DESCRIPTION
"Description."
::= { hwSLOGEudmMibGroups 1 }
-- 1.3.6.1.4.1.2011.5.25.16.2.3.2.2
hwSLOGEudmFlowLogEnableGroup OBJECT-GROUP
OBJECTS {
hwSLogEudmFlowEnableFlag,
hwSLogEudmEnableHostAcl }
STATUS current
DESCRIPTION
"Description."
::= { hwSLOGEudmMibGroups 2 }
END
--
-- HUAWEI-SLOG-EUDM-MIB.mib
--