-- File : mmblade.mib
|
|
-- Description : Management Module MIB for SNMP
|
|
-- Version : 6.3
|
|
-- Date : July 2013
|
|
-- Copyright (c) 2002-2013 IBM All Rights Reserved.
|
|
-- ********************************************************************************
|
|
--
|
|
-- Contains MIB description for:
|
|
-- This MIB is to be used to provide configuration support and monitoring for the
|
|
-- BladeCenter, BladeCenter T, BladeCenter H, and BladeCenter HT.
|
|
-- ********************************************************************************
|
|
BLADE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE FROM RFC-1212
|
|
enterprises FROM RFC1155-SMI
|
|
-- DisplayString FROM RFC1213-MIB
|
|
IpAddress FROM RFC1155-SMI
|
|
TRAP-TYPE FROM RFC-1215;
|
|
-- textual conventions
|
|
|
|
InetAddressIPv6 ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "2x:2x:2x:2x:2x:2x:2x:2x"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents an IPv6 network address. Since MIB browsers
|
|
may require different formats, the address is
|
|
expected to be the 16 byte address in network-byte order,
|
|
and shortened formats such as 0::0 are not accepted in SET
|
|
operations. Two common examples are:
|
|
|
|
The NetSNMP command line will accept SET requests like:
|
|
snmpset -v1 -cprivate <host> s 2001:00:00:00:FFFF:CCC4:BBB2:AAA6
|
|
|
|
Other MIB browsers may require the SET request value to be formatted as:
|
|
# 0x20 0x01 0x00 0x00 0x00 0x00 0x00 0x00 0xFF 0xFF 0xCC 0xC4 0xBB 0xB2 0xAA 0xA6"
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
|
|
EntryStatus ::= INTEGER
|
|
{ valid(1),
|
|
createRequest(2),
|
|
underCreation(3),
|
|
invalid(4)
|
|
}
|
|
|
|
-- The status of a table entry.
|
|
--
|
|
-- Setting this object to the value invalid(4) has the
|
|
-- effect of invalidating the corresponding entry.
|
|
-- That is, it effectively disassociates the mapping
|
|
-- identified with said entry.
|
|
-- It is an implementation-specific matter as to whether
|
|
-- the agent removes an invalidated entry from the table.
|
|
-- Accordingly, management stations must be prepared to
|
|
-- receive tabular information from agents that corresponds
|
|
-- to entries currently not in use. Proper
|
|
-- interpretation of such entries requires examination
|
|
-- of the relevant EntryStatus object.
|
|
--
|
|
-- An existing instance of this object cannot be set to
|
|
-- createRequest(2). This object may only be set to
|
|
-- createRequest(2) when this instance is created. When
|
|
-- this object is created, the agent may wish to create
|
|
-- supplemental object instances to complete a conceptual
|
|
-- row in this table. Immediately after completing the
|
|
-- create operation, the agent must set this object to
|
|
-- underCreation(3).
|
|
--
|
|
-- Entries shall exist in the underCreation(3) state until
|
|
|
|
-- the management station is finished configuring the
|
|
-- entry and sets this object to valid(1) or aborts,
|
|
-- setting this object to invalid(4). If the agent
|
|
-- determines that an entry has been in the
|
|
-- underCreation(3) state for an abnormally long time,
|
|
-- it may decide that the management station has
|
|
-- crashed. If the agent makes this decision,
|
|
-- it may set this object to invalid(4) to reclaim the
|
|
-- entry. A prudent agent will understand that the
|
|
-- management station may need to wait for human input
|
|
-- and will allow for that possibility in its
|
|
-- determination of this abnormally long period.
|
|
|
|
-- IBM enterprise group
|
|
ibm OBJECT IDENTIFIER ::= { enterprises 2 }
|
|
|
|
-- IBM products group
|
|
ibmAgents OBJECT IDENTIFIER ::= { ibm 3 }
|
|
|
|
-- IBM Advanced System Management Support Processor (SP) agent group
|
|
netfinitySupportProcessorAgent OBJECT IDENTIFIER ::= { ibmAgents 51 }
|
|
|
|
-- IBM BladeCenter Management Module (MM)
|
|
-- Also known as Advanced System Mangement (ASM) or Support Processor (SP)
|
|
bladeCenterSnmpMIB OBJECT IDENTIFIER ::= { netfinitySupportProcessorAgent 2 }
|
|
|
|
-- ********************************************************************************
|
|
-- Start: Define groups of objects within the bladeCenterSnmpMIB
|
|
-- ********************************************************************************
|
|
-- This group of objects provides the various environmental monitors for the
|
|
-- local system and the MM
|
|
monitors OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 2 }
|
|
|
|
-- This group of objects provides the error log objects for the MM
|
|
errorLogs OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 3 }
|
|
|
|
-- This group of objects provides configuration functions for the MM
|
|
configureSP OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 4 }
|
|
|
|
-- This group of objects provides system management functions for BladeCenter T
|
|
telcoManagement OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 5 }
|
|
|
|
-- This group of objects provides configuration functions for system power
|
|
-- systemPower OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 6 }
|
|
|
|
-- This group of objects provides functions to boot the MM and system
|
|
restartReset OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 7 }
|
|
|
|
-- This group of objects provides information specific to blades
|
|
blades OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 22 }
|
|
|
|
-- This group of objects provides information on the PCI-X expansion enclosure
|
|
-- pcixExpansionBox OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 21 }
|
|
|
|
-- This group of objects provides information specific to service
|
|
service OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 23 }
|
|
|
|
-- This group of objects provides information specific to scaling blades
|
|
scaling OBJECT IDENTIFIER ::= { bladeCenterSnmpMIB 24 }
|
|
|
|
-- ********************************************************************************
|
|
-- Temperature
|
|
-- ********************************************************************************
|
|
temperature OBJECT IDENTIFIER ::= { monitors 1 }
|
|
|
|
-- Planar Temperature
|
|
planarTemp OBJECT IDENTIFIER ::= { temperature 1 }
|
|
|
|
mmTemp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module temperature in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
::= { planarTemp 2 }
|
|
|
|
|
|
-- CPUx Temperature
|
|
-- cpuXTemp OBJECT IDENTIFIER ::= { temperature 2 }
|
|
|
|
-- System Ambient Temperature
|
|
ambientTemp OBJECT IDENTIFIER ::= { temperature 5 }
|
|
|
|
frontPanelTemp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The front panel temperature in degrees centigrade(C).
|
|
This is surrounding temperature where the system is installed.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
::= { ambientTemp 1 }
|
|
|
|
frontPanel2Temp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The front panel 2 temperature in degrees centigrade(C).
|
|
This is surrounding temperature where the system is installed.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
NOTE: This MIB object is for BladeCenter HT only"
|
|
::= { ambientTemp 2 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Voltages
|
|
-- ********************************************************************************
|
|
voltage OBJECT IDENTIFIER ::= { monitors 2 }
|
|
|
|
-- Planar Voltages
|
|
planarVolt OBJECT IDENTIFIER ::= { voltage 1 }
|
|
|
|
plus5Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+5 Volt power supply voltage reading expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
::= { planarVolt 1 }
|
|
|
|
plus3Pt3Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+3.3 Volt power supply voltage reading expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
::= { planarVolt 2 }
|
|
|
|
plus12Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+12 Volt power supply voltage reading expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
::= { planarVolt 3 }
|
|
|
|
minus5Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"-5 Volt power supply voltage reading expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
::= { planarVolt 5 }
|
|
|
|
plus2Pt5Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+2.5 Volt power supply voltage reading expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
::= { planarVolt 6 }
|
|
|
|
plus1Pt8Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+1.8 Volt power supply voltage reading expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
::= { planarVolt 8 }
|
|
|
|
-- ********************************************************************************
|
|
-- Blowers
|
|
-- ********************************************************************************
|
|
blowers OBJECT IDENTIFIER ::= { monitors 3 }
|
|
|
|
blower1speed OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 1 speed expressed in percent(%) of maximum RPM.
|
|
An octet string expressed as 'ddd% of maximum' where:
|
|
d is a decimal digit or blank space for a leading zero.
|
|
If the blower is determined not to be running or
|
|
the blower speed cannot be determined, the string will
|
|
indicate 'Offline'.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 1 }
|
|
|
|
blower2speed OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 2 speed expressed in percent(%) of maximum RPM.
|
|
An octet string expressed as 'ddd% of maximum' where:
|
|
d is a decimal digit or blank space for a leading zero.
|
|
If the blower is determined not to be running or
|
|
the blower speed cannot be determined, the string will
|
|
indicate 'Offline'.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 2 }
|
|
|
|
blower3speed OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 3 speed expressed in percent(%) of maximum RPM.
|
|
An octet string expressed as 'ddd% of maximum' where:
|
|
d is a decimal digit or blank space for a leading zero.
|
|
If the blower is determined not to be running or
|
|
the blower speed cannot be determined, the string will
|
|
indicate 'Offline'.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
|
|
NOTE: This MIB object is for BladeCenter T, BladeCenter HT and BladeCenter S only.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 3 }
|
|
|
|
blower4speed OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 4 speed expressed in percent(%) of maximum RPM.
|
|
An octet string expressed as 'ddd% of maximum' where:
|
|
d is a decimal digit or blank space for a leading zero.
|
|
If the blower is determined not to be running or
|
|
the blower speed cannot be determined, the string will
|
|
indicate 'Offline'.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
|
|
NOTE: This MIB object is for BladeCenter T, BladeCenter HT and BladeCenter S only.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 4 }
|
|
|
|
blower1State OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
bad(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The health state for blower 1.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 10}
|
|
|
|
blower2State OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
bad(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The health state for blower 2.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 11}
|
|
|
|
blower3State OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
bad(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The health state for blower 3.
|
|
|
|
NOTE: This MIB object is for BladeCenter T and BladeCenter S only.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 12}
|
|
|
|
blower4State OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
bad(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The health state for blower 4.
|
|
|
|
NOTE: This MIB object is for BladeCenter T and BladeCenter S only.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 13}
|
|
|
|
blower1speedRPM OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 1 speed expressed in RPM.
|
|
If the blower is determined not to be running or
|
|
the blower speed cannot be determined, the string will
|
|
indicate 'Offline'.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
|
|
NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 20 }
|
|
|
|
blower2speedRPM OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 2 speed expressed in RPM.
|
|
If the blower is determined not to be running or
|
|
the blower speed cannot be determined, the string will
|
|
indicate 'Offline'.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
|
|
NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 21 }
|
|
|
|
blower3speedRPM OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 3 speed expressed in RPM.
|
|
If the blower is determined not to be running or
|
|
the blower speed cannot be determined, the string will
|
|
indicate 'Offline'.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
|
|
NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 22 }
|
|
|
|
blower4speedRPM OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 4 speed expressed in RPM.
|
|
If the blower is determined not to be running or
|
|
the blower speed cannot be determined, the string will
|
|
indicate 'Offline'.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
|
|
NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 23 }
|
|
|
|
blower1ControllerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
operational(0),
|
|
flashing(1),
|
|
notPresent(2),
|
|
communicationError(3),
|
|
unknown(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The health state for the controller for blower 1.
|
|
|
|
NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 30}
|
|
|
|
blower2ControllerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
operational(0),
|
|
flashing(1),
|
|
notPresent(2),
|
|
communicationError(3),
|
|
unknown(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The health state for the controller for blower 2.
|
|
|
|
NOTE: This MIB object is for AMM installed in BladeCenter H, BladeCenter HT and BladeCenter S only.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 31}
|
|
|
|
blower3ControllerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
operational(0),
|
|
flashing(1),
|
|
notPresent(2),
|
|
communicationError(3),
|
|
unknown(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The health state for the controller for blower 3.
|
|
|
|
NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 32}
|
|
|
|
blower4ControllerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
operational(0),
|
|
flashing(1),
|
|
notPresent(2),
|
|
communicationError(3),
|
|
unknown(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The health state for the controller for blower 4.
|
|
|
|
NOTE: This MIB object is for AMM installed in BladeCenter HT and BladeCenter S only.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 33}
|
|
|
|
blower1ExhaustTemp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The exhaust temperature in degrees Celsius for blower 1.
|
|
|
|
NOTE: This MIB object is for BCS only.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 40}
|
|
|
|
blower2ExhaustTemp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The exhaust temperature in degrees Celsius for blower 2.
|
|
|
|
NOTE: This MIB object is for BCS only.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 41}
|
|
|
|
blower3ExhaustTemp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The exhaust temperature in degrees Celsius for blower 3.
|
|
|
|
NOTE: This MIB object is for BCS only.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 42}
|
|
|
|
blower4ExhaustTemp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The exhaust temperature in degrees Celsius for blower 4.
|
|
|
|
NOTE: This MIB object is for BCS only.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowers 43}
|
|
|
|
-- ********************************************************************************
|
|
-- Power Module Health State
|
|
-- ********************************************************************************
|
|
powerModuleHealth OBJECT IDENTIFIER ::= { monitors 4 }
|
|
|
|
powerModuleHealthTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PowerModuleHealthEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of power module health information. Contains
|
|
the power health information for each power module."
|
|
::= { powerModuleHealth 1 }
|
|
|
|
powerModuleHealthEntry OBJECT-TYPE
|
|
SYNTAX PowerModuleHealthEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Module health entry"
|
|
INDEX { powerModuleIndex }
|
|
::= { powerModuleHealthTable 1 }
|
|
|
|
|
|
PowerModuleHealthEntry ::= SEQUENCE {
|
|
powerModuleIndex INTEGER,
|
|
powerModuleExists INTEGER,
|
|
powerModuleState INTEGER,
|
|
powerModuleDetails OCTET STRING
|
|
}
|
|
|
|
powerModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module sequence index."
|
|
::= { powerModuleHealthEntry 1 }
|
|
|
|
powerModuleExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the power module specified exists or not."
|
|
::= { powerModuleHealthEntry 2 }
|
|
|
|
powerModuleState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
notAvailable(3),
|
|
critical(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The health state for the power module."
|
|
::= { powerModuleHealthEntry 3}
|
|
|
|
powerModuleDetails OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The details for this power module."
|
|
::= { powerModuleHealthEntry 4 }
|
|
|
|
-- ********************************************************************************
|
|
-- MM Status
|
|
-- ********************************************************************************
|
|
spStatus OBJECT IDENTIFIER ::= { monitors 5 }
|
|
|
|
mmBistAndChassisStatus OBJECT IDENTIFIER ::= { spStatus 2 }
|
|
|
|
|
|
bistSdram OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"MM BIST DRAM test result.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmBistAndChassisStatus 1 }
|
|
|
|
bistRs485Port1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST RS 485 legacy test result."
|
|
::= { mmBistAndChassisStatus 2 }
|
|
|
|
bistRs485Port2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST RS 485 local bus test result."
|
|
::= { mmBistAndChassisStatus 3 }
|
|
|
|
bistNvram OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"MM BIST NVRAM test result.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmBistAndChassisStatus 4 }
|
|
|
|
bistRtc OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST Real Time Clock test result."
|
|
::= { mmBistAndChassisStatus 5 }
|
|
|
|
bistLocalI2CBus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST Local I2C bus test result."
|
|
::= { mmBistAndChassisStatus 7 }
|
|
|
|
bistPrimaryMainAppFlashImage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST Primary Main Application Firmware test result."
|
|
::= { mmBistAndChassisStatus 8 }
|
|
|
|
bistSecondaryMainAppFlashImage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST Secondary Main Application test result."
|
|
::= { mmBistAndChassisStatus 9 }
|
|
|
|
bistBootRomFlashImage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST Boot Firmware test result."
|
|
::= { mmBistAndChassisStatus 10 }
|
|
|
|
bistEthernetPort1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST external ethernet port test result."
|
|
::= { mmBistAndChassisStatus 11 }
|
|
|
|
bistEthernetPort2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"MM BIST internal ethernet port test result.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmBistAndChassisStatus 12 }
|
|
|
|
bistInternalPCIBus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"MM BIST PCI bus test result.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmBistAndChassisStatus 13 }
|
|
|
|
bistExternalI2CDevices OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST external I2C devices test result."
|
|
::= { mmBistAndChassisStatus 14 }
|
|
|
|
bistUSBController OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"MM BIST USB controller test result.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmBistAndChassisStatus 15 }
|
|
|
|
bistVideoCompressorBoard OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"MM BIST Video Compressor Board test result.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmBistAndChassisStatus 16 }
|
|
|
|
bistRemoteVideo OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"MM BIST Remote Video test result.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmBistAndChassisStatus 17 }
|
|
|
|
bistPrimaryBus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST primary mid-plane bus test result."
|
|
::= { mmBistAndChassisStatus 18 }
|
|
|
|
bistInternalEthernetSwitch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST internal external switch test result."
|
|
::= { mmBistAndChassisStatus 19 }
|
|
|
|
bistVideoCapture OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST video capture test result."
|
|
::= { mmBistAndChassisStatus 20 }
|
|
|
|
bistUSBKeyboardMouseEmulation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST USB keyboard and mouse test result."
|
|
::= { mmBistAndChassisStatus 21 }
|
|
|
|
bistUSBMassStorageEmulation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST mass storage emulation test result."
|
|
::= { mmBistAndChassisStatus 22 }
|
|
|
|
bistUSBKeyboardMouseFirmware OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST USB keyboard and mouse firmware test result."
|
|
::= { mmBistAndChassisStatus 23 }
|
|
|
|
bistUSBMassStorageFirmware OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST USB keyboard mouse firmware test result."
|
|
::= { mmBistAndChassisStatus 24 }
|
|
|
|
bistPrimaryCore OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST primary core test result."
|
|
::= { mmBistAndChassisStatus 25 }
|
|
|
|
bistSecondaryCore OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST secondary core test result."
|
|
::= { mmBistAndChassisStatus 26 }
|
|
|
|
bistInternalIOExpander OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST internal IO expander test result."
|
|
::= { mmBistAndChassisStatus 27 }
|
|
|
|
bistRemoteControlFirmware OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST Remote Control firmware test result."
|
|
::= { mmBistAndChassisStatus 28 }
|
|
|
|
bistPhysicalNetworkLink OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST Physical Network Link test result."
|
|
::= { mmBistAndChassisStatus 29 }
|
|
|
|
bistLogicalNetworkLink OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM BIST Logical Network Link test result."
|
|
::= { mmBistAndChassisStatus 30 }
|
|
|
|
bistBladesInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blades that are installed on the chassis.
|
|
The blades are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of blades supported. If a blade is installed in a
|
|
bay, a 1 is present in the string in the position representing
|
|
the bay ID as read from left to right. For example, if blades
|
|
are installed in bays 1, 5, and 13, and 14 blades are supported,
|
|
the string would look like '10001000000010'."
|
|
::= { mmBistAndChassisStatus 33 }
|
|
|
|
bistBladesCommunicating OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blades that are communicating on the chassis.
|
|
The blades are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of blades supported. If a blade installed in a
|
|
bay is communicating, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if blades are communicating in bays 1, 5, and 13, and 14 blades
|
|
are supported, the string would look like '10001000000010'."
|
|
::= { mmBistAndChassisStatus 49 }
|
|
|
|
bistBlowersInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blowers that are installed on the chassis.
|
|
The blowers are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of blowers supported. If a blower is installed in a
|
|
bay, a 1 is present in the string in the position representing
|
|
the bay ID as read from left to right. For example, if a blower
|
|
is installed in bay 1, and 2 blowers are supported, the string
|
|
would look like '10'.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { mmBistAndChassisStatus 65 }
|
|
|
|
bistBlowersFunctional OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blowers installed on the chassis that are functional.
|
|
The blowers are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of blowers supported. If a blower is installed and
|
|
functional in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if a blower is installed and functional only in bay 1, and 2 blowers
|
|
are supported, the string would look like '10'.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { mmBistAndChassisStatus 73 }
|
|
|
|
bistMediaTrayInstalled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether a media tray is installed on the chassis."
|
|
::= { mmBistAndChassisStatus 74 }
|
|
|
|
bistMediaTrayCommunicating OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether a media tray is communicating."
|
|
::= { mmBistAndChassisStatus 75 }
|
|
|
|
bistOtherMMInstalled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether a redundant MM is installed."
|
|
::= { mmBistAndChassisStatus 76 }
|
|
|
|
bistOtherMMCommunicating OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether a redundant MM is communicating."
|
|
::= { mmBistAndChassisStatus 77 }
|
|
|
|
bistPowerModulesInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power modules that are installed on the chassis.
|
|
The power modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of power modules supported. If a power module is
|
|
installed in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if power modules are installed in bays 1 and 3, and 4 power modules
|
|
are supported, the string would look like '1010'."
|
|
::= { mmBistAndChassisStatus 81 }
|
|
|
|
bistPowerModulesFunctional OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power modules that are functional on the chassis.
|
|
The power modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of power modules supported. If a power module is
|
|
installed and functioning in a bay, a 1 is present in the string
|
|
in the position representing the bay ID as read from left to right.
|
|
For example, if power modules are installed and functioning in bays
|
|
1 and 3, and 4 power modules are supported, the string would look
|
|
like '1010'."
|
|
::= { mmBistAndChassisStatus 89 }
|
|
|
|
bistSwitchModulesInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch modules that are installed on the chassis.
|
|
The switch modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of switch modules supported. If a switch module is
|
|
installed in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if switch modules are installed in bays 1 and 3, and 4 switch modules
|
|
are supported, the string would look like '1011' for BladeCenter and
|
|
BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT."
|
|
::= { mmBistAndChassisStatus 97 }
|
|
|
|
bistSwitchModulesCommunicating OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch modules that are communicating on the chassis.
|
|
The switch modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of switch modules supported. If a switch module is
|
|
installed and functioning in a bay, a 1 is present in the string
|
|
in the position representing the bay ID as read from left to right.
|
|
For example, if switch modules are installed and functioning in bays
|
|
1 and 3, and 4 switch modules are supported, the string would look
|
|
like for BladeCenter and BladeCenter T and '1011000000' for
|
|
BladeCenter H and BladeCenter HT."
|
|
::= { mmBistAndChassisStatus 113 }
|
|
|
|
bistLastUpdate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"It is the time when the primary MM updated the last BIST results."
|
|
::= { mmBistAndChassisStatus 200 }
|
|
|
|
rmmBistAndChassisStatus OBJECT IDENTIFIER ::= { spStatus 3 }
|
|
|
|
rbistRs485Port1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST RS 485 legacy test result. The time of the last update
|
|
can be obtained by querying rbistUpdateTime object."
|
|
::= { rmmBistAndChassisStatus 2 }
|
|
|
|
rbistRs485Port2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST RS 485 local bus test result. The time of the last update
|
|
can be obtained by querying rbistUpdateTime object."
|
|
::= { rmmBistAndChassisStatus 3 }
|
|
|
|
rbistRtc OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST Real Time Clock test result. The time of the last update
|
|
can be obtained by querying rbistUpdateTime object."
|
|
::= { rmmBistAndChassisStatus 5 }
|
|
|
|
rbistLocalI2CBus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST Local I2C bus test result. The time of the last update
|
|
can be obtained by querying rbistUpdateTime object."
|
|
::= { rmmBistAndChassisStatus 7 }
|
|
|
|
rbistPrimaryMainAppFlashImage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST Primary Main Application Firmware test result.
|
|
The time of the last update can be obtained by querying rbistUpdateTime object."
|
|
::= { rmmBistAndChassisStatus 8 }
|
|
|
|
rbistSecondaryMainAppFlashImage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST Secondary Main Application test result.
|
|
The time of the last update can be obtained by querying rbistUpdateTime object."
|
|
::= { rmmBistAndChassisStatus 9 }
|
|
|
|
rbistBootRomFlashImage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST Boot Firmware test result. The time of the last update
|
|
can be obtained by querying rbistUpdateTime object."
|
|
::= { rmmBistAndChassisStatus 10 }
|
|
|
|
rbistEthernetPort1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST external ethernet port test result. The time of the last update
|
|
can be obtained by querying rbistUpdateTime object."
|
|
::= { rmmBistAndChassisStatus 11 }
|
|
|
|
rbistExternalI2CDevices OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST external I2C devices test result collected
|
|
when the standby MM was primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object."
|
|
::= { rmmBistAndChassisStatus 14 }
|
|
|
|
rbistInternalEthernetSwitch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST internal external switch test result.
|
|
The time of the last update can be obtained by querying rbistUpdateTime object."
|
|
::= { rmmBistAndChassisStatus 19 }
|
|
|
|
rbistVideoCapture OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST video capture test result collected
|
|
when the standby MM was primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object."
|
|
::= { rmmBistAndChassisStatus 20 }
|
|
|
|
rbistUSBKeyboardMouseEmulation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST USB keyboard and mouse test result collected
|
|
when the standby MM was primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object."
|
|
::= { rmmBistAndChassisStatus 21 }
|
|
|
|
rbistUSBMassStorageEmulation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST mass storage emulation test result collected
|
|
when the standby MM was primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object."
|
|
::= { rmmBistAndChassisStatus 22 }
|
|
|
|
rbistUSBKeyboardMouseFirmware OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST USB keyboard and mouse firmware test result
|
|
collected when the standby MM was primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object."
|
|
::= { rmmBistAndChassisStatus 23 }
|
|
|
|
rbistUSBMassStorageFirmware OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST USB keyboard mouse firmware test result collected
|
|
when the standby MM was primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object."
|
|
::= { rmmBistAndChassisStatus 24 }
|
|
|
|
rbistPrimaryCore OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST primary core test result. The time of the last update
|
|
can be obtained by querying rbistUpdateTime object."
|
|
::= { rmmBistAndChassisStatus 25 }
|
|
|
|
rbistSecondaryCore OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST secondary core test result. The time of the last update
|
|
can be obtained by querying rbistUpdateTime object."
|
|
::= { rmmBistAndChassisStatus 26 }
|
|
|
|
rbistInternalIOExpander OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST internal IO expander test result. The time of the last update
|
|
can be obtained by querying rbistUpdateTime object."
|
|
::= { rmmBistAndChassisStatus 27 }
|
|
|
|
rbistRemoteControlFirmware OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST Remote Control firmware test result collected
|
|
when the standby MM was primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object."
|
|
::= { rmmBistAndChassisStatus 28 }
|
|
|
|
rbistPhysicalNetworkLink OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST Physical Network Link test result collected
|
|
when the standby MM was primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object."
|
|
::= { rmmBistAndChassisStatus 29 }
|
|
|
|
rbistLogicalNetworkLink OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testSucceeded(0),
|
|
testFailed(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Standby MM BIST Logical Network Link test result collected
|
|
when the standby MM was primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object."
|
|
::= { rmmBistAndChassisStatus 30 }
|
|
|
|
rbistBladesInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blades that were installed on the chassis when the
|
|
standby MM was once primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object.
|
|
The blades are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of blades supported. If a blade is installed in a
|
|
bay, a 1 is present in the string in the position representing
|
|
the bay ID as read from left to right. For example, if blades
|
|
are installed in bays 1, 5, and 13, and 14 blades are supported,
|
|
the string would look like '10001000000010'. "
|
|
::= { rmmBistAndChassisStatus 33 }
|
|
|
|
rbistBladesCommunicating OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blades that were communicating on the chassis when the
|
|
standby MM was once primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object.
|
|
The blades are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of blades supported. If a blade installed in a
|
|
bay is communicating, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if blades are communicating in bays 1, 5, and 13, and 14 blades
|
|
are supported, the string would look like '10001000000010'."
|
|
::= { rmmBistAndChassisStatus 49 }
|
|
|
|
rbistBlowersInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blowers that were installed on the chassis when the
|
|
standby MM was once primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object.
|
|
The blowers are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of blowers supported. If a blower is installed in a
|
|
bay, a 1 is present in the string in the position representing
|
|
the bay ID as read from left to right. For example, if a blower
|
|
is installed in bay 1, and 2 blowers are supported, the string
|
|
would look like '10'.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { rmmBistAndChassisStatus 65 }
|
|
|
|
rbistBlowersFunctional OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blowers installed on the chassis that were functional when the
|
|
standby MM was once primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object.
|
|
The blowers are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of blowers supported. If a blower is installed and
|
|
functional in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if a blower is installed and functional only in bay 1, and 2 blowers
|
|
are supported, the string would look like '10'.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { rmmBistAndChassisStatus 73 }
|
|
|
|
rbistMediaTrayInstalled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether a media tray was installed on the chassis when the
|
|
standby MM was once primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object."
|
|
::= { rmmBistAndChassisStatus 74 }
|
|
|
|
rbistMediaTrayCommunicating OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether a media tray was communicating when the
|
|
standby MM was once primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object."
|
|
::= { rmmBistAndChassisStatus 75 }
|
|
|
|
rbistOtherMMInstalled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether a standby MM was installed when the
|
|
standby MM was once primary.The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object."
|
|
::= { rmmBistAndChassisStatus 76 }
|
|
|
|
rbistOtherMMCommunicating OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether a standby MM was communicating when the
|
|
standby MM was once primary. The time of the last update can be
|
|
gotten from the object 'rbistUpdateTimePrimary'."
|
|
::= { rmmBistAndChassisStatus 77 }
|
|
|
|
rbistPowerModulesInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power modules that were installed on the chassis when the
|
|
standby MM was once primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object.
|
|
The power modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of power modules supported. If a power module was
|
|
installed in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if power modules were installed in bays 1 and 3, and 4 power modules
|
|
were supported, the string would look like '1010'."
|
|
::= { rmmBistAndChassisStatus 81 }
|
|
|
|
rbistPowerModulesFunctional OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power modules that were functional on the chassis when the
|
|
standby MM was once primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object.
|
|
The power modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of power modules supported. If a power module was
|
|
installed and functioning in a bay, a 1 is present in the string
|
|
in the position representing the bay ID as read from left to right.
|
|
For example, if power modules were installed and functioning in bays
|
|
1 and 3, and 4 power modules were supported, the string would look
|
|
like '1010'."
|
|
::= { rmmBistAndChassisStatus 89 }
|
|
|
|
rbistSwitchModulesInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch modules that were installed on the chassis when the
|
|
standby MM was once primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object.
|
|
The switch modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of switch modules supported. If a switch module was
|
|
installed in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if switch modules were installed in bays 1 and 3, and 4 switch modules
|
|
were supported, the string would look like '1011' for BladeCenter and
|
|
BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT."
|
|
::= { rmmBistAndChassisStatus 97 }
|
|
|
|
rbistSwitchModulesCommunicating OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch modules that are communicating on the chassis when the
|
|
standby MM was once primary. The time of the last update
|
|
can be obtained by querying rbistUpdateTimePrimary object.
|
|
The switch modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of switch modules supported. If a switch module was
|
|
installed and functioning in a bay, a 1 is present in the string
|
|
in the position representing the bay ID as read from left to right.
|
|
For example, if switch modules were installed and functioning in bays
|
|
1 and 3, and 4 switch modules were supported, the string would look
|
|
like for BladeCenter and BladeCenter T and '1011000000' for
|
|
BladeCenter H and BladeCenter HT."
|
|
::= { rmmBistAndChassisStatus 113 }
|
|
|
|
rbistUpdateTime OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"It is the time when the standby MM updated the last BIST results."
|
|
::= { rmmBistAndChassisStatus 200 }
|
|
|
|
rbistLastUpdatePrimary OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"It is the time when the standby MM updated the last BIST results
|
|
when it was still primary."
|
|
::= { rmmBistAndChassisStatus 201 }
|
|
|
|
-- ********************************************************************************
|
|
-- Fan Pack Health State
|
|
-- ********************************************************************************
|
|
fanPack OBJECT IDENTIFIER ::= { monitors 6 }
|
|
|
|
fanPackTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FanPackEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of fan pack information. Contains
|
|
the information for each fan pack.
|
|
|
|
NOTE: Fan packs are also referred to as Power Module Cooling Devices."
|
|
::= { fanPack 1 }
|
|
|
|
fanPackEntry OBJECT-TYPE
|
|
SYNTAX FanPackEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan Pack entry"
|
|
INDEX { fanPackIndex }
|
|
::= { fanPackTable 1 }
|
|
|
|
|
|
FanPackEntry ::= SEQUENCE {
|
|
fanPackIndex INTEGER,
|
|
fanPackExists INTEGER,
|
|
fanPackState INTEGER,
|
|
fanPackFanCount INTEGER,
|
|
fanPackAverageSpeed OCTET STRING,
|
|
fanPackAverageSpeedRPM OCTET STRING,
|
|
fanPackControllerState INTEGER
|
|
}
|
|
|
|
fanPackIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan Pack sequence index."
|
|
::= { fanPackEntry 1 }
|
|
|
|
fanPackExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the fan pack specified exists or not."
|
|
::= { fanPackEntry 2 }
|
|
|
|
fanPackState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
bad(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The health state for the fan pack.
|
|
0 = unknown, 1 = good, 2 = warning, 3 = bad."
|
|
::= { fanPackEntry 3}
|
|
|
|
fanPackFanCount OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of fans in the fan pack."
|
|
::= { fanPackEntry 4 }
|
|
|
|
fanPackAverageSpeed OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The average speed of all fans in the fan pack expressed in percent(%)
|
|
of maximum RPM. If the fan pack is determined not to be running or
|
|
the fan pack speed cannot be determined, the string will
|
|
indicate 'Offline'. The string 'Not Readable!' indicates that the
|
|
given monitor is not supported on this system."
|
|
::= { fanPackEntry 5 }
|
|
|
|
fanPackAverageSpeedRPM OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The average speed of all fans in the fan pack expressed in RPM.
|
|
If the fan pack is determined not to be running or the fan pack speed
|
|
cannot be determined, the string will indicate 'Offline'. The string
|
|
'Not Readable!' indicates that the given monitor is not supported on
|
|
this system."
|
|
::= { fanPackEntry 6 }
|
|
|
|
fanPackControllerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
operational(0),
|
|
flashing(1),
|
|
notPresent(2),
|
|
communicationError(3),
|
|
unknown(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The health state for the controller for the fan pack.
|
|
0 = operational, 1 = flashing in progress, 2 = not present, 3 = communication error,
|
|
255 = unknown"
|
|
::= { fanPackEntry 7}
|
|
|
|
-- ********************************************************************************
|
|
-- System Health
|
|
-- ********************************************************************************
|
|
systemHealth OBJECT IDENTIFIER ::= { monitors 7 }
|
|
|
|
-- ********************************************************************************
|
|
-- System Health Status
|
|
-- ********************************************************************************
|
|
systemHealthStat OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
critical(0),
|
|
nonCritical(2),
|
|
systemLevel(4),
|
|
normal(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates status of system health for the
|
|
system in which the MM resides.
|
|
Value of 'critical' indicates a severe error has occurred
|
|
and the system may not be functioning. A value of
|
|
'nonCritical' indicates that a error has occurred but
|
|
the system is currently functioning properly. A value of
|
|
'systemLevel' indicates that a condition has occurred
|
|
that may change the state of the system in the future but currently
|
|
the system is working properly. A value of
|
|
'normal' indicates that the system is operating normally."
|
|
::= { systemHealth 1 }
|
|
|
|
-- ********************************************************************************
|
|
-- System Health Summary
|
|
-- ********************************************************************************
|
|
systemHealthSummaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SystemHealthSummaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of System Health summary. Contains more detailed
|
|
information about the reasons for the overall system
|
|
health status.
|
|
|
|
NOTE: This MIB object is for BladeCenter only."
|
|
::= { systemHealth 2 }
|
|
|
|
systemHealthSummaryEntry OBJECT-TYPE
|
|
SYNTAX SystemHealthSummaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System Health Summary entry
|
|
|
|
NOTE: This MIB object is for BladeCenter only."
|
|
INDEX { systemHealthSummaryIndex }
|
|
::= { systemHealthSummaryTable 1 }
|
|
|
|
|
|
SystemHealthSummaryEntry ::= SEQUENCE {
|
|
systemHealthSummaryIndex INTEGER,
|
|
systemHealthSummarySeverity OCTET STRING,
|
|
systemHealthSummaryDescription OCTET STRING,
|
|
systemHealthSummaryDateTime OCTET STRING
|
|
}
|
|
|
|
|
|
systemHealthSummaryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System health summary index.
|
|
|
|
NOTE: This MIB object is for BladeCenter only."
|
|
::= { systemHealthSummaryEntry 1 }
|
|
|
|
systemHealthSummarySeverity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System health summary severity.
|
|
|
|
NOTE: This MIB object is for BladeCenter only."
|
|
::= { systemHealthSummaryEntry 2 }
|
|
|
|
systemHealthSummaryDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System health summary description.
|
|
|
|
NOTE: This MIB object is for BladeCenter only."
|
|
::= { systemHealthSummaryEntry 3 }
|
|
|
|
systemHealthSummaryDateTime OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System health summary date time.
|
|
|
|
NOTE: This MIB object is for BladeCenter only."
|
|
::= { systemHealthSummaryEntry 4 }
|
|
|
|
-- ********************************************************************************
|
|
-- LEDs
|
|
-- ********************************************************************************
|
|
leds OBJECT IDENTIFIER ::= { monitors 8 }
|
|
|
|
-- ********************************************************************************
|
|
-- Front Panel LEDs
|
|
-- ********************************************************************************
|
|
frontPanelLEDs OBJECT IDENTIFIER ::= { leds 1 }
|
|
|
|
|
|
systemErrorLED OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the front panel system error LED is on or off.
|
|
|
|
NOTE: This MIB object is for BladeCenter only."
|
|
::= { frontPanelLEDs 1 }
|
|
|
|
|
|
informationLED OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the front panel system information LED
|
|
is on or off. For Write access, the LED can be turned off
|
|
only.
|
|
|
|
NOTE: This MIB object is for BladeCenter only."
|
|
::= { frontPanelLEDs 2 }
|
|
|
|
|
|
temperatureLED OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the front panel temperature LED is on or off.
|
|
|
|
NOTE: This MIB object is for BladeCenter only."
|
|
::= { frontPanelLEDs 3 }
|
|
|
|
|
|
identityLED OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
blinking(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the front panel identity LED is on or off.
|
|
|
|
NOTE: This MIB object is for BladeCenter only."
|
|
::= { frontPanelLEDs 4 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Blade LEDs
|
|
-- ********************************************************************************
|
|
bladeLEDs OBJECT IDENTIFIER ::= { leds 2 }
|
|
|
|
bladeLEDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade status information.
|
|
|
|
NOTE: Querying objects in this table may take significantly longer
|
|
than normal, so it is recommended that the query timeout be set to
|
|
a large value. On a fully populated chassis, the timeout should be set
|
|
to 120 seconds or more."
|
|
::= { bladeLEDs 1 }
|
|
|
|
bladeLEDsEntry OBJECT-TYPE
|
|
SYNTAX BladeLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade system status entry"
|
|
INDEX { bladeStatusIndex }
|
|
::= { bladeLEDsTable 1 }
|
|
|
|
|
|
BladeLEDsEntry ::= SEQUENCE {
|
|
ledBladeIndex INTEGER,
|
|
ledBladeId INTEGER,
|
|
ledBladeExists INTEGER,
|
|
ledBladePowerState INTEGER,
|
|
ledBladeHealthState INTEGER,
|
|
ledBladeName OCTET STRING,
|
|
ledBladeSystemError INTEGER,
|
|
ledBladeInformation INTEGER,
|
|
ledBladeKVM INTEGER,
|
|
ledBladeMediaTray INTEGER,
|
|
ledBladeIdentity INTEGER
|
|
}
|
|
|
|
|
|
ledBladeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade LED table index."
|
|
::= { bladeLEDsEntry 1 }
|
|
|
|
ledBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeLEDsEntry 2 }
|
|
|
|
ledBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeLEDsEntry 3 }
|
|
|
|
ledBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
standby(3),
|
|
hibernate(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the power state of the blade specified."
|
|
::= { bladeLEDsEntry 4 }
|
|
|
|
ledBladeHealthState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
critical(3),
|
|
kernelMode(4),
|
|
discovering(5),
|
|
commError(6),
|
|
noPower(7),
|
|
flashing(8),
|
|
initFailure(9),
|
|
insufficientPower(10),
|
|
powerDenied(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system health state for the blade.
|
|
|
|
Unknown: Blade is in an undefined state.
|
|
Good: Blade is operating normally.
|
|
Warning: One or more outstanding warnings exist for this blade.
|
|
Critical: One or more outstanding critical events for this blade.
|
|
Kernel Mode: Blade is in kernel mode.
|
|
Discovering: The AMM is currently in the process of discovering this blade.
|
|
Communications Error: The AMM failed to communicate with this blade.
|
|
No Power: No power to the blade's domain.
|
|
Flashing: Flashing in progress.
|
|
Initialization Failure: Blade failed to initialized.
|
|
Insufficient Power: Not enough power is left in the blade's domain to power the blade.
|
|
Power Denied: Power was denied to the blade."
|
|
::= { bladeLEDsEntry 5 }
|
|
|
|
ledBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeLEDsEntry 6 }
|
|
|
|
ledBladeSystemError OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade system error LED is on or off."
|
|
::= { bladeLEDsEntry 7 }
|
|
|
|
ledBladeInformation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade information LED is on or off.
|
|
For Write access, the LED can be turned off only."
|
|
::= { bladeLEDsEntry 8 }
|
|
|
|
ledBladeKVM OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
blinking(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade KVM LED is on, off, or blinking."
|
|
::= { bladeLEDsEntry 9 }
|
|
|
|
ledBladeMediaTray OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
blinking(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade media tray LED is on, off, or blinking."
|
|
::= { bladeLEDsEntry 10 }
|
|
|
|
ledBladeIdentity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
blinking(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade identify LED is on, off, or blinking."
|
|
::= { bladeLEDsEntry 11 }
|
|
|
|
bladeLEDsDetailsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeLEDsDetailsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade LEDs detailed information.
|
|
|
|
NOTE: Querying objects in this table may take significantly longer
|
|
than normal, so it is recommended that the query timeout be set to
|
|
a large value. On a fully populated chassis, the timeout should be set
|
|
to 120 seconds or more."
|
|
::= { bladeLEDs 2 }
|
|
|
|
bladeLEDsDetailsEntry OBJECT-TYPE
|
|
SYNTAX BladeLEDsDetailsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade LEDs Details entry"
|
|
INDEX { ledIndex }
|
|
::= { bladeLEDsDetailsTable 1 }
|
|
|
|
BladeLEDsDetailsEntry ::= SEQUENCE {
|
|
ledIndex INTEGER,
|
|
ledBladeBayNumber OCTET STRING,
|
|
ledBladeComponentType OCTET STRING,
|
|
ledBladeLabel OCTET STRING,
|
|
ledBladeState INTEGER,
|
|
ledBladeLocation OCTET STRING
|
|
}
|
|
|
|
ledIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The LED index number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeLEDsDetailsEntry 1 }
|
|
|
|
ledBladeBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bay number of the main server blade that the LED is grouped into.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeLEDsDetailsEntry 2 }
|
|
|
|
ledBladeComponentType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of the component/subcomponent grouping for this LED.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeLEDsDetailsEntry 3 }
|
|
|
|
ledBladeLabel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Text label for a LED.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeLEDsDetailsEntry 4 }
|
|
|
|
ledBladeState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
blinking(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Text description which denotes color or on/off/blink state for a LED.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeLEDsDetailsEntry 5 }
|
|
|
|
ledBladeLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Location of this LED.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeLEDsDetailsEntry 6 }
|
|
|
|
-- ***********************************************************************
|
|
-- BladeCenter T Panel LEDs
|
|
-- ***********************************************************************
|
|
telcoPanelLEDs OBJECT IDENTIFIER ::= { leds 3 }
|
|
|
|
|
|
criticalLED OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the BladeCenter T Panel CRT (Critical) LED is on or off.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
::= { telcoPanelLEDs 1 }
|
|
|
|
|
|
majorLED OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the BladeCenter T Panel MJR (Major) LED is on or off.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
::= { telcoPanelLEDs 2 }
|
|
|
|
minorLED OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the BladeCenter T Panel MNR (Minor) LED is on or off.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
::= { telcoPanelLEDs 3 }
|
|
|
|
|
|
telcoIdentityLED OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
blinking(2),
|
|
notAvailable(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the BladeCenter T Panel identity LED is on or off.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
::= { telcoPanelLEDs 4 }
|
|
|
|
|
|
telcoColorSel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
amber(0),
|
|
red(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the BladeCenter T Critical and Major LEDs are displayed in amber or red color.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
::= { telcoPanelLEDs 5 }
|
|
|
|
|
|
|
|
criticalityAssertionMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the BladeCenter T Criticality Assertion Mode is enabled or disabled.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
::= { telcoPanelLEDs 6 }
|
|
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Switch Module LEDs
|
|
-- ********************************************************************************
|
|
smLEDs OBJECT IDENTIFIER ::= { leds 4 }
|
|
|
|
smLEDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SMLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of switch module LEDs information."
|
|
::= { smLEDs 1 }
|
|
|
|
smLEDsEntry OBJECT-TYPE
|
|
SYNTAX SMLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module LEDs information entry"
|
|
INDEX { ledSMIndex }
|
|
::= { smLEDsTable 1 }
|
|
|
|
|
|
SMLEDsEntry ::= SEQUENCE {
|
|
ledSMIndex INTEGER,
|
|
ledSMLEDs OCTET STRING
|
|
}
|
|
|
|
|
|
ledSMIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..128)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module LEDs table index. "
|
|
::= { smLEDsEntry 1 }
|
|
|
|
ledSMLEDs OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(256))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A bitmap of LEDs information on the selected switch module. The
|
|
bitmap is a string containing a list of 1's and 0's. Every 4 bytes
|
|
are used to represent a led state. The first 64 bytes represent the
|
|
status of the external LEDs while the last 64 bytes represent the
|
|
status of the internal port connections from the switch module to
|
|
blades. Each nibble of data is presented in the bitmap format (0000)
|
|
and is encoded as followed
|
|
- 0000: LED is not present
|
|
- 0001: LED is off
|
|
- 0010: LED is on
|
|
|
|
NOTE: The data is read from left to right, starting out with blade
|
|
server 1 and so on."
|
|
::= { smLEDsEntry 2 }
|
|
|
|
-- ********************************************************************************
|
|
-- Blower LEDs
|
|
-- ********************************************************************************
|
|
blowerLEDs OBJECT IDENTIFIER ::= { leds 5 }
|
|
|
|
blowerLEDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BlowerLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blower LEDs information.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowerLEDs 1 }
|
|
|
|
blowerLEDsEntry OBJECT-TYPE
|
|
SYNTAX BlowerLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower LEDs information entry"
|
|
INDEX { ledBlowerIndex }
|
|
::= { blowerLEDsTable 1 }
|
|
|
|
|
|
BlowerLEDsEntry ::= SEQUENCE {
|
|
ledBlowerIndex INTEGER,
|
|
ledBlowerId INTEGER,
|
|
ledBlowerExists INTEGER,
|
|
ledBlowerError INTEGER
|
|
}
|
|
|
|
ledBlowerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..128)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower LEDs table index. "
|
|
::= { blowerLEDsEntry 1 }
|
|
|
|
ledBlowerId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blower1(1),
|
|
blower2(2),
|
|
blower3(3),
|
|
blower4(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { blowerLEDsEntry 2 }
|
|
|
|
ledBlowerExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blower specified exists or not."
|
|
::= { blowerLEDsEntry 3 }
|
|
|
|
ledBlowerError OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
notAvailable(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blower error LED is on, off, or not available."
|
|
::= { blowerLEDsEntry 4 }
|
|
|
|
-- ********************************************************************************
|
|
-- Fan Pack LEDs
|
|
-- ********************************************************************************
|
|
fanPackLEDs OBJECT IDENTIFIER ::= { leds 6 }
|
|
|
|
fanPackLEDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FanPackLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of fan pack LEDs information.
|
|
|
|
NOTE: Fan packs are also referred to as Power Module Cooling Devices."
|
|
::= { fanPackLEDs 1 }
|
|
|
|
fanPackLEDsEntry OBJECT-TYPE
|
|
SYNTAX FanPackLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan Pack LEDs information entry"
|
|
INDEX { ledFanPackIndex }
|
|
::= { fanPackLEDsTable 1 }
|
|
|
|
|
|
FanPackLEDsEntry ::= SEQUENCE {
|
|
ledFanPackIndex INTEGER,
|
|
ledFanPackId INTEGER,
|
|
ledFanPackExists INTEGER,
|
|
ledFanPackError INTEGER
|
|
}
|
|
|
|
|
|
ledFanPackIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..128)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan Pack LEDs table index. "
|
|
::= { fanPackLEDsEntry 1 }
|
|
|
|
ledFanPackId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fanPack1(1),
|
|
fanPack2(2),
|
|
fanPack3(3),
|
|
fanPack4(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric fan pack ID."
|
|
::= { fanPackLEDsEntry 2 }
|
|
|
|
ledFanPackExists OBJECT-TYPE
|
|
SYNTAX INTEGER (0..128)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the fan pack specified exists or not."
|
|
::= { fanPackLEDsEntry 3 }
|
|
|
|
ledFanPackError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..128)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the fan pack error LED is on or off."
|
|
::= { fanPackLEDsEntry 4 }
|
|
|
|
-- ********************************************************************************
|
|
-- BCHT ONLY - Hardware Component Status LEDs
|
|
-- ********************************************************************************
|
|
-- Media Tray Status LEDs
|
|
-- ********************************************************************************
|
|
mtStatusLEDs OBJECT IDENTIFIER ::= { leds 7 }
|
|
|
|
mtStatusLEDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MtStatusLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Media Tray Status LEDs information.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mtStatusLEDs 1 }
|
|
|
|
mtStatusLEDsEntry OBJECT-TYPE
|
|
SYNTAX MtStatusLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media Tray Status LEDs information entry.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
INDEX { ledMediaTrayIndex }
|
|
::= { mtStatusLEDsTable 1 }
|
|
|
|
|
|
MtStatusLEDsEntry ::= SEQUENCE {
|
|
ledMediaTrayIndex INTEGER,
|
|
ledMediaTrayId INTEGER,
|
|
ledMediaTrayExists INTEGER,
|
|
ledMediaTrayFault INTEGER
|
|
}
|
|
|
|
|
|
ledMediaTrayIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..128)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media Tray Status LEDs table index.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mtStatusLEDsEntry 1 }
|
|
|
|
|
|
ledMediaTrayId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
topmediatray(1),
|
|
botmediatray(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric Media Tray ID.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mtStatusLEDsEntry 2 }
|
|
|
|
ledMediaTrayExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the Media Tray exists or not.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mtStatusLEDsEntry 3 }
|
|
|
|
ledMediaTrayFault OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the Media Tray Fault LED is on or off.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mtStatusLEDsEntry 5 }
|
|
|
|
-- ********************************************************************************
|
|
-- Telco Alarm Panel Tray Status LEDs
|
|
-- ********************************************************************************
|
|
tapStatusLEDs OBJECT IDENTIFIER ::= { leds 8 }
|
|
|
|
tapExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the Alarm Panel exists or not.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { tapStatusLEDs 3 }
|
|
|
|
tapFRRLED OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the Alarm Panel Safe To Remove LED is on or off.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { tapStatusLEDs 4 }
|
|
|
|
|
|
tapFaultLED OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the Alarm Panel Fault LED is on or off.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { tapStatusLEDs 5 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Network Clock Status LEDs
|
|
-- ********************************************************************************
|
|
ncStatusLEDs OBJECT IDENTIFIER ::= { leds 9 }
|
|
|
|
ncStatusLEDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NcStatusLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Table of Network Clock Status LEDs information.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { ncStatusLEDs 1 }
|
|
|
|
ncStatusLEDsEntry OBJECT-TYPE
|
|
SYNTAX NcStatusLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock Status LEDs information entry.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
INDEX { ledNetworkClockIndex }
|
|
::= { ncStatusLEDsTable 1 }
|
|
|
|
|
|
NcStatusLEDsEntry ::= SEQUENCE {
|
|
ledNetworkClockIndex INTEGER,
|
|
ledNetworkClockId INTEGER,
|
|
ledNetworkClockExists INTEGER,
|
|
ledNetworkClockFRR INTEGER,
|
|
ledNetworkClockFault INTEGER
|
|
}
|
|
|
|
|
|
ledNetworkClockIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..128)
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock Status LEDs table index.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { ncStatusLEDsEntry 1 }
|
|
|
|
|
|
ledNetworkClockId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
networkclock1(1),
|
|
networkclock2(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The numeric Network Clock ID.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { ncStatusLEDsEntry 2 }
|
|
|
|
ledNetworkClockExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Indicates whether the Network Clock exists or not.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { ncStatusLEDsEntry 3 }
|
|
|
|
ledNetworkClockFRR OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Indicates whether the Network Clock Safe To Remove LED is on or off.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { ncStatusLEDsEntry 4 }
|
|
|
|
ledNetworkClockFault OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Indicates whether the Network Clock Fault LED is on or off.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { ncStatusLEDsEntry 5 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Multiplexer Expansion Module Status LEDs
|
|
-- ********************************************************************************
|
|
mxStatusLEDs OBJECT IDENTIFIER ::= { leds 10 }
|
|
|
|
mxStatusLEDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MxStatusLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Multiplexer Expansion Module Status LEDs information.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mxStatusLEDs 1 }
|
|
|
|
mxStatusLEDsEntry OBJECT-TYPE
|
|
SYNTAX MxStatusLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Multiplexer Expansion Module Status LEDs information entry.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
INDEX { ledMuxIndex }
|
|
::= { mxStatusLEDsTable 1 }
|
|
|
|
|
|
MxStatusLEDsEntry ::= SEQUENCE {
|
|
ledMuxIndex INTEGER,
|
|
ledMuxId INTEGER,
|
|
ledMuxExists INTEGER,
|
|
ledMuxFRR INTEGER,
|
|
ledMuxFault INTEGER
|
|
}
|
|
|
|
|
|
ledMuxIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..128)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Multiplexer Expansion Module Status LEDs table index.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mxStatusLEDsEntry 1 }
|
|
|
|
|
|
ledMuxId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
mux1(1),
|
|
mux2(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric Multiplexer Expansion Module ID.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mxStatusLEDsEntry 2 }
|
|
|
|
ledMuxExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the Multiplexer Expansion Module exists or not.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mxStatusLEDsEntry 3 }
|
|
|
|
ledMuxFRR OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the Multiplexer Expansion Module Safe To Remove LED is on or off.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mxStatusLEDsEntry 4 }
|
|
|
|
ledMuxFault OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the Multiplexer Expansion Module Fault LED is on or off.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mxStatusLEDsEntry 5 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Storage LEDs
|
|
-- ********************************************************************************
|
|
storageLEDs OBJECT IDENTIFIER ::= { leds 11 }
|
|
|
|
storageLEDsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF StorageLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of storage module LEDs information.
|
|
|
|
NOTE: This MIB object is for BladeCenter S only."
|
|
::= { storageLEDs 1 }
|
|
|
|
storageLEDsEntry OBJECT-TYPE
|
|
SYNTAX StorageLEDsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module LEDs information entry
|
|
|
|
NOTE: This MIB object is for BladeCenter S only."
|
|
INDEX { ledStorageIndex }
|
|
::= { storageLEDsTable 1 }
|
|
|
|
|
|
StorageLEDsEntry ::= SEQUENCE {
|
|
ledStorageIndex INTEGER,
|
|
ledStorageId INTEGER,
|
|
ledStorageExists INTEGER,
|
|
ledStorageError INTEGER
|
|
}
|
|
|
|
|
|
ledStorageIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module LEDs table index.
|
|
|
|
NOTE: This MIB object is for BladeCenter S only."
|
|
::= { storageLEDsEntry 1 }
|
|
|
|
ledStorageId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
storage1(1),
|
|
storage2(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric storage module ID.
|
|
|
|
NOTE: This MIB object is for BladeCenter S only."
|
|
::= { storageLEDsEntry 2 }
|
|
|
|
ledStorageExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the storage module specified exists or not.
|
|
|
|
NOTE: This MIB object is for BladeCenter S only."
|
|
::= { storageLEDsEntry 3 }
|
|
|
|
ledStorageError OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
blinking(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the status of the storage module error LED.
|
|
|
|
NOTE: This MIB object is for BladeCenter S only."
|
|
::= { storageLEDsEntry 4 }
|
|
|
|
-- ************************************************************************
|
|
-- BladeCenter T System Health
|
|
-- ************************************************************************
|
|
telcoSystemHealth OBJECT IDENTIFIER ::= { monitors 9 }
|
|
|
|
-- ************************************************************************
|
|
-- BladeCenter T System Health Status
|
|
-- ************************************************************************
|
|
telcoSystemHealthStat OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
critical-power(6),
|
|
critical(5),
|
|
major-power(4),
|
|
major(3),
|
|
minor-power(2),
|
|
minor(1),
|
|
normal(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates status of system health for the system in which the
|
|
MM resides. Value of 'critical' indicates a non-recoverable
|
|
service affecting condition has occurred that requires an
|
|
immediate action. A value of 'major' indicates a critical
|
|
service affecting condition has occurred that requires an urgent
|
|
action. A value of 'minor' indicates a non-service affecting
|
|
condition has occurred. Corrective action should be taken in
|
|
order to prevent a more serious fault. A value of 'normal'
|
|
indicates that the system is operating normally. Severity level
|
|
with '-power' indicates the failure relates to the power resource.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
::= { telcoSystemHealth 1 }
|
|
|
|
-- ************************************************************************
|
|
-- BladeCenter T System Health Summary
|
|
-- ************************************************************************
|
|
telcoSystemHealthSummaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TelcoSystemHealthSummaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of System Health summary. Contains more detailed
|
|
information about the reasons for the overall system
|
|
health status.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only.
|
|
NOTE: This table may contain one entry if no alarms are in progress. That one entry,
|
|
if present, contains no alarms but a message of 'Good' in the severity object."
|
|
::= { telcoSystemHealth 2 }
|
|
|
|
telcoSystemHealthSummaryEntry OBJECT-TYPE
|
|
SYNTAX TelcoSystemHealthSummaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"BladeCenter T System Health Summary entry.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
INDEX { telcoSystemHealthSummaryIndex }
|
|
::= { telcoSystemHealthSummaryTable 1 }
|
|
|
|
|
|
TelcoSystemHealthSummaryEntry ::= SEQUENCE {
|
|
telcoSystemHealthSummaryIndex INTEGER,
|
|
telcoSystemHealthSummarySeverity OCTET STRING,
|
|
telcoSystemHealthSummaryDescription OCTET STRING,
|
|
telcoSystemHealthSummaryEventName INTEGER,
|
|
telcoSystemHealthSummaryEventKeyID OCTET STRING,
|
|
telcoSystemHealthSummaryAcknowledge INTEGER,
|
|
telcoSystemHealthSummaryAssertTime OCTET STRING
|
|
}
|
|
|
|
|
|
telcoSystemHealthSummaryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"BladeCenter T System Health Summary Index.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
::= { telcoSystemHealthSummaryEntry 1 }
|
|
|
|
telcoSystemHealthSummarySeverity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"BladeCenter T System Health Summary Severity. The values
|
|
and meanings are as follows:
|
|
0x06 Critical-Power
|
|
0x05 Critical
|
|
0x04 Major-Power
|
|
0x03 Major
|
|
0x02 Minor-Power
|
|
0x01 Minor
|
|
0xFF Normal
|
|
|
|
NOTE: This MIB object is for BladeCenter T only.
|
|
NOTE: If no alarms are in progress, this object contains 'Good'."
|
|
::= { telcoSystemHealthSummaryEntry 2 }
|
|
|
|
telcoSystemHealthSummaryDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"BladeCenter T System Health Summary Description.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only.
|
|
NOTE: If no alarms are in progress, this object contains 'No alarm events'."
|
|
::= { telcoSystemHealthSummaryEntry 3 }
|
|
|
|
telcoSystemHealthSummaryEventName OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"BladeCenter T System Health Summary Event Name.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
::= { telcoSystemHealthSummaryEntry 4 }
|
|
|
|
telcoSystemHealthSummaryEventKeyID OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"BladeCenter T System Health Summary Event Key ID. An octet string
|
|
expressed as 'mmm:ggg:iii:aaa:sss' where:
|
|
m : Module ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
g : Gen ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
i : GenInfo ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
a : Alarm ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
s : Alarm severity value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
|
|
|
|
NOTE: This MIB object is for BladeCenter T only.
|
|
NOTE: If no alarms are in progress, this object contains 'No alarm events'."
|
|
::= { telcoSystemHealthSummaryEntry 5 }
|
|
|
|
telcoSystemHealthSummaryAcknowledge OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unacknowledged(0),
|
|
acknowledged(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"BladeCenter T System Health Summary Acknowledge. Indicates whether the
|
|
alarm event is acknowledged or unacknowledged.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
::= { telcoSystemHealthSummaryEntry 6 }
|
|
|
|
telcoSystemHealthSummaryAssertTime OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"BladeCenter T System Health Summary Assert Time.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only.
|
|
NOTE: If no alarms are in progress, this object contains 'No alarm events'."
|
|
::= { telcoSystemHealthSummaryEntry 7 }
|
|
|
|
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Fuel Gauge / Power Management
|
|
-- ********************************************************************************
|
|
fuelGauge OBJECT IDENTIFIER ::= { monitors 10 }
|
|
|
|
-- ********************************************************************************
|
|
-- Fuel Gauge
|
|
-- ********************************************************************************
|
|
fuelGaugeInformation OBJECT IDENTIFIER ::= { fuelGauge 1 }
|
|
|
|
fuelGaugeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FuelGaugeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Fuel Gauge information."
|
|
::= { fuelGaugeInformation 1 }
|
|
|
|
fuelGaugeEntry OBJECT-TYPE
|
|
SYNTAX FuelGaugeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel Gauge entry"
|
|
INDEX { fuelGaugeIndex }
|
|
::= { fuelGaugeTable 1 }
|
|
|
|
FuelGaugeEntry ::= SEQUENCE {
|
|
fuelGaugeIndex INTEGER,
|
|
fuelGaugePowerDomainNumber INTEGER,
|
|
fuelGaugeStatus OCTET STRING,
|
|
fuelGaugeFirstPowerModule OCTET STRING,
|
|
fuelGaugeSecondPowerModule OCTET STRING,
|
|
fuelGaugePowerManagementPolicySetting INTEGER,
|
|
fuelGaugeTotalPower OCTET STRING,
|
|
fuelGaugeAllocatedPower OCTET STRING,
|
|
fuelGaugeRemainingPower OCTET STRING,
|
|
fuelGaugePowerInUsed OCTET STRING
|
|
}
|
|
|
|
fuelGaugeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel Gauge Table Index."
|
|
::= { fuelGaugeEntry 1 }
|
|
|
|
fuelGaugePowerDomainNumber OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
powerDomain1(1),
|
|
powerDomain2(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel Gauge Table Power Domain Number."
|
|
::= { fuelGaugeEntry 2 }
|
|
|
|
fuelGaugeStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel Gauge Table Status for the power domain.
|
|
The response will start out with a numeric value (0 = unknown,
|
|
1 = good, 2 = warning, and 3: bad), followed by a text message."
|
|
::= { fuelGaugeEntry 3 }
|
|
|
|
fuelGaugeFirstPowerModule OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel Gauge Table First Power Module capacity in Watts in the power domain.
|
|
|
|
NOTE: First power module in power domain 1 and 2 is in bay 1
|
|
and 3 respectively."
|
|
::= { fuelGaugeEntry 4 }
|
|
|
|
fuelGaugeSecondPowerModule OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel Gauge Table Second Power Module capacity in Watts in the power domain.
|
|
|
|
NOTE: Second power module in power domain 1 and 2 is in bay 2
|
|
and 4 respectively."
|
|
::= { fuelGaugeEntry 5 }
|
|
|
|
fuelGaugePowerManagementPolicySetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
redundantWithoutPerformanceImpact(0),
|
|
redundantWithPerformanceImpact(1),
|
|
nonRedundant(2),
|
|
redundantACPowerSource(3),
|
|
acPowerSourceWithBladeThrottlingAllowed(4),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel Gauge Table for the Power Management Policy Setting for each power domain.
|
|
When a 1200W or 1400W power module is installed in the domain
|
|
the power management policy will not be applicable.
|
|
In addition the power consumption in this domain will not be monitored.
|
|
|
|
A new powerPolicyTable has been added which provides more detailed
|
|
information regarding a domains power policy information. This table
|
|
also has the capability to SET the power policy for a given domain.
|
|
|
|
In addition, note that the first three enumerated choices above are
|
|
referred to with updated nomenclature, as follows:
|
|
|
|
redundantWithoutPerformanceImpact(0) equals Redundant Power Modules
|
|
redundantWithPerformanceImpact(1) equals Power Modules with Blade
|
|
Throttling Allowed
|
|
nonRedundant(2) equals Basic Power Management"
|
|
::= { fuelGaugeEntry 6 }
|
|
|
|
fuelGaugeTotalPower OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This field displays the total available power for each power domain based on
|
|
installed power modules and the current Power Management Policy Setting.
|
|
When a 1200W or 1400W power module is installed in the domain
|
|
the power management policy will not be applicable.
|
|
In addition the power consumption in this domain will not be monitored."
|
|
::= { fuelGaugeEntry 7 }
|
|
|
|
fuelGaugeAllocatedPower OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This field displays the power that has been reserved in each power domain.
|
|
NOTE: 1) Power is always reserved in domain 1 for two management modules and
|
|
two I/O modules. 2) Power is reserved for I/O modules installed in bay 3 and
|
|
4 (Powered on or standby). 3) Power is reserved for each installed Blade.
|
|
Blades in a standby state (not powered on) will reserve a certain amount power.
|
|
When a 1200W or 1400W power module is installed in the domain
|
|
the power management policy will not be applicable.
|
|
In addition the power consumption in this domain will not be monitored."
|
|
::= { fuelGaugeEntry 8 }
|
|
|
|
fuelGaugeRemainingPower OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This field displays the remaining power available in each domain.
|
|
Remaining Power = Total Power minus Power In Use
|
|
When a 1200W or 1400W power module is installed in the domain
|
|
the power management policy will not be applicable.
|
|
In addition the power consumption in this domain will not be monitored."
|
|
::= { fuelGaugeEntry 9 }
|
|
|
|
fuelGaugePowerInUsed OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This field displays the total power being used in each power domain.
|
|
When a 1200W or 1400W power module is installed in the domain
|
|
the power management policy will not be applicable.
|
|
In addition the power consumption in this domain will not be monitored."
|
|
::= { fuelGaugeEntry 10 }
|
|
|
|
-- ********************************************************************************
|
|
-- Fuel Gauge Power Domain 1
|
|
-- ********************************************************************************
|
|
powerDomain1 OBJECT IDENTIFIER ::= { fuelGauge 2 }
|
|
|
|
powerDomain1Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PowerDomain1Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Power Domain 1.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices.
|
|
NOTE: Fan packs are also referred to as Power Module Cooling Devices."
|
|
::= { powerDomain1 1}
|
|
|
|
powerDomain1Entry OBJECT-TYPE
|
|
SYNTAX PowerDomain1Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel Gauge entry"
|
|
INDEX { pd1Index }
|
|
::= { powerDomain1Table 1 }
|
|
|
|
|
|
PowerDomain1Entry ::= SEQUENCE {
|
|
pd1Index INTEGER,
|
|
pd1BayNumber OCTET STRING,
|
|
pd1BladePrimarySlot INTEGER,
|
|
pd1ModuleStatus INTEGER,
|
|
pd1ModuleName OCTET STRING,
|
|
pd1ModuleState INTEGER,
|
|
pd1ModuleAllocatedPowerCurrent OCTET STRING,
|
|
pd1ModuleAllocatedPowerMax OCTET STRING,
|
|
pd1ModuleAllocatedPowerMin OCTET STRING,
|
|
pd1ModuleCPUDutyCycles OCTET STRING,
|
|
pd1ModuleThrottle INTEGER,
|
|
pd1ModulePowerCapabilities INTEGER,
|
|
pd1ModuleMeasuredOrStatic INTEGER
|
|
}
|
|
|
|
pd1Index OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Index."
|
|
::= { powerDomain1Entry 1 }
|
|
|
|
pd1BayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Bay Number.
|
|
The following Bay Number IDs are used in the BladeCenter:
|
|
notApplicable(1),
|
|
notApplicable(2),
|
|
blowerBay1(3),
|
|
blowerBay2(4),
|
|
managementModuleBay1(5),
|
|
managementModuleBay2(6),
|
|
switchModuleBay1(7),
|
|
switchModuleBay2(8),
|
|
switchModuleBay3(9),
|
|
switchModuleBay4(10),
|
|
serverBladeBay1(11),
|
|
serverBladeBay2(12),
|
|
serverBladeBay3(13),
|
|
serverBladeBay4(14),
|
|
serverBladeBay5(15),
|
|
serverBladeBay6(16),
|
|
notApplicable(17)
|
|
The following Bay Number IDs are used in the BladeCenter H:
|
|
notApplicable(1),
|
|
notApplicable(2),
|
|
fanPackBay1(3),
|
|
fanPackBay2(4),
|
|
fanPackBay3(5),
|
|
fanPackBay4(6),
|
|
managementModuleBay1(7),
|
|
managementModuleBay2(8),
|
|
ioModuleBay1(9),
|
|
ioModuleBay2(10),
|
|
ioModuleBay3(11),
|
|
ioModuleBay4(12),
|
|
ioModuleBay7(13),
|
|
ioModuleBay8(14),
|
|
ioModuleBay9(15),
|
|
ioModuleBay10(16),
|
|
serverBladeBay1(17),
|
|
serverBladeBay2(18),
|
|
serverBladeBay3(19),
|
|
serverBladeBay4(20),
|
|
serverBladeBay5(21),
|
|
serverBladeBay6(22),
|
|
serverBladeBay7(23),
|
|
notApplicable(24)
|
|
The following Bay Number IDs are used in the BladeCenter T:
|
|
notApplicable(1),
|
|
notApplicable(2),
|
|
blowerBay1(3),
|
|
blowerBay2(4),
|
|
blowerBay3(5) (if Power Domain 2 is not available),
|
|
blowerBay4(6) (if Power Domain 2 is not available),
|
|
managementModuleBay1(7),
|
|
managementModuleBay2(8),
|
|
switchModuleBay1(9),
|
|
switchModuleBay2(10),
|
|
switchModuleBay3(11),
|
|
switchModuleBay4(12),
|
|
serverBladeBay1(13),
|
|
serverBladeBay2(14),
|
|
serverBladeBay3(15),
|
|
serverBladeBay4(16),
|
|
notApplicable(17)
|
|
The following Bay Number IDs are used in the BladeCenter HT:
|
|
notApplicable(1),
|
|
mediatrayBay1(2),
|
|
mediatrayBay2(3),
|
|
fanPackBay1(4),
|
|
fanPackBay2(5),
|
|
fanPackBay3(6),
|
|
fanPackBay4(7),
|
|
blowerBay1(8),
|
|
blowerBay2(9),
|
|
blowerBay3(10),
|
|
blowerBay4(11),
|
|
networkclockBay1(12),
|
|
networkclockBay2(13),
|
|
midplaneelectroBay1(14),
|
|
midplaneelectroBay2(15),
|
|
notApplicable(16),
|
|
managementModuleBay1(17),
|
|
managementModuleBay2(18),
|
|
ioModuleBay1(19),
|
|
ioModuleBay2(20),
|
|
ioModuleBay3(21),
|
|
ioModuleBay4(22),
|
|
serverBladeBay1(23),
|
|
serverBladeBay2(24),
|
|
serverBladeBay3(25),
|
|
serverBladeBay4(26),
|
|
serverBladeBay5(27),
|
|
serverBladeBay6(28),
|
|
notApplicable(29)
|
|
The following Bay Number IDs are used in the BladeCenter S:
|
|
notApplicable(1),
|
|
notApplicable(2),
|
|
fanPackBay1(3),
|
|
fanPackBay2(4),
|
|
fanPackBay3(5),
|
|
fanPackBay4(6),
|
|
blowerBay1(7),
|
|
blowerBay2(8),
|
|
blowerBay3(9),
|
|
blowerBay4(10),
|
|
storageModuleBay1(11),
|
|
storageModuleBay2(12),
|
|
managementModuleBay(13),
|
|
ioModuleBay1(14),
|
|
ioModuleBay2(15),
|
|
ioModuleBay3(16),
|
|
ioModuleBay4(17),
|
|
serverBladeBay1(18),
|
|
serverBladeBay2(19),
|
|
serverBladeBay3(20),
|
|
serverBladeBay4(21),
|
|
serverBladeBay5(22),
|
|
serverBladeBay6(23),
|
|
notApplicable(24)"
|
|
::= { powerDomain1Entry 2 }
|
|
|
|
pd1BladePrimarySlot OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Blade Primary Slot can be useful
|
|
when a server blade spans multiple slots (e.g. double wide or
|
|
triple wide). For example if the blade is double wide and
|
|
is installed in slot 3 and 4. 3 is primary slot while 4 is not."
|
|
::= { powerDomain1Entry 3 }
|
|
|
|
pd1ModuleStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
insufficientPower(0),
|
|
moduleIsThrottling(1),
|
|
moduleNotThrottling(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Module Throttle Status."
|
|
::= { powerDomain1Entry 4 }
|
|
|
|
pd1ModuleName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Module Name."
|
|
::= { powerDomain1Entry 5 }
|
|
|
|
pd1ModuleState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standby(0),
|
|
on(1),
|
|
notPresent(2),
|
|
off(3),
|
|
hibernate(4),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Module State."
|
|
::= { powerDomain1Entry 6 }
|
|
|
|
pd1ModuleAllocatedPowerCurrent OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Allocated Power Current indicates the current power
|
|
allocation for the module in Watts. When a 1200W or 1400W power module is
|
|
installed in the domain the power management policy will not be applicable.
|
|
In addition the power consumption in this domain will not be monitored.
|
|
|
|
NOTE: When a server blade spans multiple slots (e.g. double wide or
|
|
triple wide), the current power allocation for the module is equally
|
|
divided among the slots."
|
|
::= { powerDomain1Entry 7 }
|
|
|
|
pd1ModuleAllocatedPowerMax OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Allocated Power Max indicates the maximum power
|
|
allocation for the module in Watts. It is indicative of the maximum
|
|
amount of power the module will consume in the domain when it is
|
|
fully populated with memory chips, expansion cards, etc.
|
|
When a 1200W or 1400W power module is installed in the domain
|
|
the power management policy will not be applicable.
|
|
In addition the power consumption in this domain will not be monitored.
|
|
|
|
NOTE: When a server blade spans multiple slots (e.g. double wide or
|
|
triple wide), the maximum power allocation for the module is equally
|
|
divided among the slots."
|
|
::= { powerDomain1Entry 8 }
|
|
|
|
pd1ModuleAllocatedPowerMin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Allocated Power Min indicates the minumum power
|
|
allocation for the module in Watts. It is indicative of the minumum
|
|
power consumption of the component in the domain based on its
|
|
maximum throttle limit. When a 1200W or 1400W power module is installed
|
|
in the domain the power management policy will not be applicable.
|
|
In addition the power consumption in this domain will not be monitored.
|
|
|
|
NOTE: When a server blade spans multiple slots (e.g. double wide or
|
|
triple wide), the minimum power allocation for the module is equally
|
|
divided among the slots."
|
|
::= { powerDomain1Entry 9 }
|
|
|
|
pd1ModuleCPUDutyCycles OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Module CPUs Duty Cycles applies to blade
|
|
servers only. It displays the duty cycle for each CPU on the blade
|
|
as a percentage. Note that some blades do not report the CPU
|
|
duty cycles. In this case, 'notApplicable' will be displayed.
|
|
When a 1200W or 1400W power module is installed in the domain
|
|
the power management policy will not be applicable.
|
|
In addition the power consumption in this domain will not be monitored.
|
|
|
|
NOTE: The CPU duty cycles are reported only on a primary slot when
|
|
a server blade spans multiple slots (e.g. double wide or
|
|
triple wide). For example if the blade is double wide and
|
|
is installed in slot 3 and 4. 3 is primary slot while 4 is not.
|
|
The CPU duty cycles are reported on slot 3 while 'notApplicable'
|
|
is displayed for slot 4."
|
|
::= { powerDomain1Entry 10 }
|
|
|
|
pd1ModuleThrottle OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Module Throttle indicates whether the
|
|
server blade may be allowed to throttle or not.
|
|
When a 1200W or 1400W power module is installed in the domain
|
|
the power management policy will not be applicable.
|
|
In addition the power consumption in this domain will not be monitored."
|
|
::= { powerDomain1Entry 11 }
|
|
|
|
pd1ModulePowerCapabilities OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAbility(0),
|
|
staticPowerManagement(1),
|
|
fixedPowerManagement(2),
|
|
dynamicPowerManagement(3),
|
|
dynamicPowerMeasurement1(4),
|
|
dynamicPowerMeasurement2(5),
|
|
dynamicPowerMeasurementWithPowerCapping(6),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Module Power Capabilities.
|
|
|
|
staticPowerManagement: the module with the static worst
|
|
case power values.
|
|
fixedPowermanagement: the module with the static power values but
|
|
ability to throttle.
|
|
dynamicPowerManagement: the module with power meter capability,
|
|
measurement enabled, but capping disabled.
|
|
dynamicPowerMeasurement1: the module with power meter capability,
|
|
measurement enabled, phase 1 only
|
|
dynamicPowerMeasurement2: the module with power meter capability,
|
|
measurement enabled, phase 2 or higher
|
|
dynamicPowerMeasurementWithPowerCapping: the module with power
|
|
meter capability, both measurement and capping enabled,
|
|
phase 2 or higher"
|
|
::= { powerDomain1Entry 12 }
|
|
|
|
pd1ModuleMeasuredOrStatic OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
static(0),
|
|
measured(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Table Module Measured Or Static."
|
|
::= { powerDomain1Entry 13 }
|
|
|
|
powerDomain1PowerTrending OBJECT IDENTIFIER ::= { powerDomain1 3 }
|
|
|
|
pd1PowerTrendingPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lastHour(0),
|
|
last6Hours(1),
|
|
last12Hours(2),
|
|
last24Hours(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specify time period for power domain 1 power trending information
|
|
table view.
|
|
|
|
NOTE: This time period should be configured before displaying the
|
|
following Power Trending Information table for Power Domain."
|
|
::= { powerDomain1PowerTrending 1 }
|
|
|
|
pd1PowerTrendingSampleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Pd1PowerTrendingSampleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Power Domain 1 Power Trending Information."
|
|
::= { powerDomain1PowerTrending 10 }
|
|
|
|
pd1PowerTrendingSampleEntry OBJECT-TYPE
|
|
SYNTAX Pd1PowerTrendingSampleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Power Trending Sample entry."
|
|
INDEX { pd1PowerTrendingSampleIndex }
|
|
::= { pd1PowerTrendingSampleTable 1 }
|
|
|
|
Pd1PowerTrendingSampleEntry ::= SEQUENCE {
|
|
pd1PowerTrendingSampleIndex INTEGER,
|
|
pd1PowerTrendingSampleTimeStamp OCTET STRING,
|
|
pd1PowerTrendingSampleAve OCTET STRING
|
|
}
|
|
|
|
pd1PowerTrendingSampleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Power Trending Sample Table Index."
|
|
::= { pd1PowerTrendingSampleEntry 1 }
|
|
|
|
pd1PowerTrendingSampleTimeStamp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Power Trending Sample Table Timestamp."
|
|
::= { pd1PowerTrendingSampleEntry 2 }
|
|
|
|
pd1PowerTrendingSampleAve OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 1 Power Trending Table Average Power."
|
|
::= { pd1PowerTrendingSampleEntry 3 }
|
|
|
|
-- ********************************************************************************
|
|
-- Fuel Gauge Power Domain 2
|
|
-- ********************************************************************************
|
|
powerDomain2 OBJECT IDENTIFIER ::= { fuelGauge 3 }
|
|
|
|
powerDomain2Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PowerDomain2Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Power Domain 2.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices.
|
|
NOTE: Fan packs are also referred to as Power Module Cooling Devices."
|
|
::= { powerDomain2 1 }
|
|
|
|
powerDomain2Entry OBJECT-TYPE
|
|
SYNTAX PowerDomain2Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel Gauge entry"
|
|
INDEX { pd2Index }
|
|
::= { powerDomain2Table 1 }
|
|
|
|
PowerDomain2Entry ::= SEQUENCE {
|
|
pd2Index INTEGER,
|
|
pd2BayNumber OCTET STRING,
|
|
pd2BladePrimarySlot INTEGER,
|
|
pd2ModuleStatus INTEGER,
|
|
pd2ModuleName OCTET STRING,
|
|
pd2ModuleState INTEGER,
|
|
pd2ModuleAllocatedPowerCurrent OCTET STRING,
|
|
pd2ModuleAllocatedPowerMax OCTET STRING,
|
|
pd2ModuleAllocatedPowerMin OCTET STRING,
|
|
pd2ModuleCPUDutyCycles OCTET STRING,
|
|
pd2ModuleThrottle INTEGER,
|
|
pd2ModulePowerCapabilities INTEGER,
|
|
pd2ModuleMeasuredOrStatic INTEGER
|
|
}
|
|
|
|
pd2Index OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Index."
|
|
::= { powerDomain2Entry 1 }
|
|
|
|
pd2BayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Bay Number.
|
|
The following Bay Number IDs are used in the BladeCenter:
|
|
serverBladeBay7(1),
|
|
serverBladeBay8(2),
|
|
serverBladeBay9(3),
|
|
serverBladeBay10(4),
|
|
serverBladeBay11(5),
|
|
serverBladeBay12(6),
|
|
serverBladeBay13(7),
|
|
serverBladeBay14(8),
|
|
notApplicable(9)
|
|
The following Bay Number IDs are used in the BladeCenter H:
|
|
notApplicable(1),
|
|
notApplicable(2),
|
|
fanPackBay1(3),
|
|
fanPackBay2(4),
|
|
fanPackBay3(5),
|
|
fanPackBay4(6),
|
|
managementModuleBay1(7),
|
|
managementModuleBay2(8),
|
|
ioModuleBay1(9),
|
|
ioModuleBay2(10),
|
|
ioModuleBay3(11),
|
|
ioModuleBay4(12),
|
|
ioModuleBay7(13),
|
|
ioModuleBay8(14),
|
|
ioModuleBay9(15),
|
|
ioModuleBay10(16),
|
|
serverBladeBay8(17),
|
|
serverBladeBay9(18),
|
|
serverBladeBay10(19),
|
|
serverBladeBay11(20),
|
|
serverBladeBay12(21),
|
|
serverBladeBay13(22),
|
|
serverBladeBay14(23),
|
|
notApplicable(24)
|
|
The following Bay Number IDs are used in the BladeCenter T:
|
|
blowerBay3(1),
|
|
blowerBay4(2),
|
|
serverBladeBay5(3),
|
|
serverBladeBay6(4),
|
|
serverBladeBay7(5),
|
|
serverBladeBay8(6),
|
|
notApplicable(7),
|
|
notApplicable(8),
|
|
notApplicable(9)
|
|
The following Bay Number IDs are used in the BladeCenter HT:
|
|
fanPackBay1(1),
|
|
fanPackBay2(2),
|
|
fanPackBay3(3),
|
|
fanPackBay4(4),
|
|
blowerBay1(5),
|
|
blowerBay2(6),
|
|
blowerBay3(7),
|
|
blowerBay4(8),
|
|
ioModuleBay7(9),
|
|
ioModuleBay8(10),
|
|
ioModuleBay9(11),
|
|
ioModuleBay10(12),
|
|
serverBladeBay7(13),
|
|
serverBladeBay8(14),
|
|
serverBladeBay9(15),
|
|
serverBladeBay10(16),
|
|
serverBladeBay11(17),
|
|
serverBladeBay12(18),
|
|
notApplicable(19)"
|
|
::= { powerDomain2Entry 2 }
|
|
|
|
pd2BladePrimarySlot OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Blade Primary Slot can be useful
|
|
when a server blade spans multiple slots (e.g. double wide or
|
|
triple wide). For example if the blade is double wide and
|
|
is installed in slot 3 and 4. 3 is primary slot while 4 is not."
|
|
::= { powerDomain2Entry 3 }
|
|
|
|
pd2ModuleStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
insufficientPower(0),
|
|
moduleIsThrottling(1),
|
|
moduleNotThrottling(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Module throttle status."
|
|
::= { powerDomain2Entry 4 }
|
|
|
|
pd2ModuleName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Module Name."
|
|
::= { powerDomain2Entry 5 }
|
|
|
|
pd2ModuleState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standby(0),
|
|
on(1),
|
|
notPresent(2),
|
|
off(3),
|
|
hibernate(4),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Power State."
|
|
::= { powerDomain2Entry 6 }
|
|
|
|
pd2ModuleAllocatedPowerCurrent OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Allocated Power Current indicates the current power
|
|
allocation for the module. When a 1200W or 1400W power module is
|
|
installed in the domain the power management policy will not be applicable.
|
|
In addition the power consumption in this domain will not be monitored.
|
|
|
|
NOTE: When a server blade spans multiple slots (e.g. double wide or
|
|
triple wide), the current power allocation for the module is equally
|
|
divided among the slots."
|
|
::= { powerDomain2Entry 7 }
|
|
|
|
pd2ModuleAllocatedPowerMax OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Allocated Power Max indicates the maximum power
|
|
allocation for the module in Watts. It is indicative of the maximum
|
|
amount of power the module will consume in the domain when it is
|
|
fully populated with memory chips, expansion cards, etc.
|
|
When a 1200W or 1400W power module is installed in the domain
|
|
the power management policy will not be applicable. In addition
|
|
the power consumption in this domain will not be monitored.
|
|
|
|
NOTE: When a server blade spans multiple slots (e.g. double wide or
|
|
triple wide), the maximum power allocation for the module is equally
|
|
divided among the slots."
|
|
::= { powerDomain2Entry 8 }
|
|
|
|
pd2ModuleAllocatedPowerMin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Allocated Power Min indicates the minumum power
|
|
allocation for the module in Watts. It is indicative of the minumum
|
|
power consumption of the component in the domain based on its
|
|
maximum throttle limit. When a 1200W or 1400W power module is
|
|
installed in the domain the power management policy will not be applicable.
|
|
In addition the power consumption in this domain will not be monitored.
|
|
|
|
NOTE: When a server blade spans multiple slots (e.g. double wide or
|
|
triple wide), the minimum power allocation for the module is equally
|
|
divided among the slots."
|
|
::= { powerDomain2Entry 9 }
|
|
|
|
pd2ModuleCPUDutyCycles OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Module CPUs Duty Cycles applies to blade
|
|
servers only. It displays the duty cycle for each CPU on the blade
|
|
as a percentage. Note that some blades do not report the CPU
|
|
duty cycles. In this case, 'notApplicable' will be displayed.
|
|
When a 1200W or 1400W power module is installed in the domain
|
|
the power management policy will not be applicable.
|
|
In addition the power consumption in this domain will not be monitored.
|
|
|
|
NOTE: The CPU duty cycles are reported only on a primary slot when
|
|
a server blade spans multiple slots (e.g. double wide or
|
|
triple wide). For example if the blade is double wide and
|
|
is installed in slot 3 and 4. 3 is primary slot while 4 is not.
|
|
The CPU duty cycles are reported on slot 3 while 'notApplicable'
|
|
is displayed for slot 4. "
|
|
::= { powerDomain2Entry 10 }
|
|
|
|
pd2ModuleThrottle OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Module Throttle indicates whether the
|
|
server blade may be allowed to throttle or not.
|
|
When a 1200W or 1400W power module is installed in the domain
|
|
the power management policy will not be applicable.
|
|
In addition the power consumption in this domain will not be monitored."
|
|
::= { powerDomain2Entry 11 }
|
|
|
|
pd2ModulePowerCapabilities OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAbility(0),
|
|
staticPowerManagement(1),
|
|
fixedPowerManagement(2),
|
|
dynamicPowerManagement(3),
|
|
dynamicPowerMeasurement1(4),
|
|
dynamicPowerMeasurement2(5),
|
|
dynamicPowerMeasurementWithPowerCapping(6),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Module Power Capabilities.
|
|
|
|
staticPowerManagement: the module with the static worst
|
|
case power values.
|
|
fixedPowermanagement: the module with the static power values but
|
|
ability to throttle.
|
|
dynamicPowerManagement: the module with power meter capability,
|
|
measurement enabled, but capping disabled.
|
|
dynamicPowerMeasurement1: the module with power meter capability,
|
|
measurement enabled, phase 1 only
|
|
dynamicPowerMeasurement2: the module with power meter capability,
|
|
measurement enabled, phase 2 or higher
|
|
dynamicPowerMeasurementWithPowerCapping: the module with power
|
|
meter capability, both measurement and capping enabled,
|
|
phase 2 or higher"
|
|
::= { powerDomain2Entry 12 }
|
|
|
|
pd2ModuleMeasuredOrStatic OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
static(0),
|
|
measured(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Table Module Measured Or Static."
|
|
::= { powerDomain2Entry 13 }
|
|
|
|
powerDomain2PowerTrending OBJECT IDENTIFIER ::= { powerDomain2 3 }
|
|
|
|
pd2PowerTrendingPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lastHour(0),
|
|
last6Hours(1),
|
|
last12Hours(2),
|
|
last24Hours(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specify time period for power domain 2 power trending information
|
|
table view.
|
|
|
|
NOTE: This time period should be configured before displaying the
|
|
following Power Trending Information table for Power Domain."
|
|
::= { powerDomain2PowerTrending 1 }
|
|
|
|
pd2PowerTrendingSampleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Pd2PowerTrendingSampleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Power Domain 2 Power Trending Sample Information."
|
|
::= { powerDomain2PowerTrending 10 }
|
|
|
|
pd2PowerTrendingSampleEntry OBJECT-TYPE
|
|
SYNTAX Pd2PowerTrendingSampleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Power Trending Sample entry."
|
|
INDEX { pd2PowerTrendingSampleIndex }
|
|
::= { pd2PowerTrendingSampleTable 1 }
|
|
|
|
Pd2PowerTrendingSampleEntry ::= SEQUENCE {
|
|
pd2PowerTrendingSampleIndex INTEGER,
|
|
pd2PowerTrendingSampleTimeStamp OCTET STRING,
|
|
pd2PowerTrendingSampleAve OCTET STRING
|
|
}
|
|
|
|
pd2PowerTrendingSampleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Power Trending Sample Table Index."
|
|
::= { pd2PowerTrendingSampleEntry 1 }
|
|
|
|
pd2PowerTrendingSampleTimeStamp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Power Trending Sample Table Timestamp."
|
|
::= { pd2PowerTrendingSampleEntry 2 }
|
|
|
|
pd2PowerTrendingSampleAve OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Domain 2 Power Trending Sample Table Average Power."
|
|
::= { pd2PowerTrendingSampleEntry 3 }
|
|
|
|
moduleInformation OBJECT IDENTIFIER ::= { fuelGauge 4 }
|
|
|
|
bladeDetails OBJECT IDENTIFIER ::= { moduleInformation 1 }
|
|
|
|
bladeDetailsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeDetailsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Blade Module Details."
|
|
::= { bladeDetails 1}
|
|
|
|
bladeDetailsEntry OBJECT-TYPE
|
|
SYNTAX BladeDetailsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Module Details entry."
|
|
INDEX { bladeDetailsIndex }
|
|
::= { bladeDetailsTable 1 }
|
|
|
|
BladeDetailsEntry ::= SEQUENCE {
|
|
bladeDetailsIndex INTEGER,
|
|
bladeDetailsId INTEGER,
|
|
bladeDetailsMaxPowerConfig INTEGER,
|
|
bladeDetailsEffectiveClockRate OCTET STRING,
|
|
bladeDetailsMaximumClockRate OCTET STRING,
|
|
bladeDetailsPowerSaverMode INTEGER,
|
|
bladeDetailsDynamicPowerSaver INTEGER,
|
|
bladeDetailsDynamicPowerFavorPerformanceOverPower INTEGER,
|
|
bladeDetailsPowerControl INTEGER
|
|
}
|
|
|
|
bladeDetailsIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Module Details Table Index."
|
|
::= { bladeDetailsEntry 1 }
|
|
|
|
bladeDetailsId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Module Details Table Blade Id."
|
|
::= { bladeDetailsEntry 2 }
|
|
|
|
bladeDetailsMaxPowerConfig OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Module Details Table Maximum Power Configuration.
|
|
Allow the user to set the maximum power that can be used by the blade. This
|
|
function is also known as power capping.
|
|
|
|
If the value of maximum power config is zero, it means the blade doesn't
|
|
support the power capping feature"
|
|
::= { bladeDetailsEntry 3 }
|
|
|
|
bladeDetailsEffectiveClockRate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Module Details Table Effective CPU Clock Rate applies to DPM
|
|
blades only. It displays processor's effective clock rate based
|
|
on sample interval. Note that some blades do not effective
|
|
clock rate. In this case, 'notApplicable' will be displayed.
|
|
When a 1200W or 1400W power module is installed in the domain
|
|
the power management policy will not be applicable.
|
|
In addition the power consumption in this domain will not be monitored.
|
|
|
|
NOTE: The effective clock rate are reported only on a primary slot when
|
|
a server blade spans multiple slots (e.g. double wide or
|
|
triple wide). For example if the blade is double wide and
|
|
is installed in slot 3 and 4. 3 is primary slot while 4 is not.
|
|
The effective clock rate are reported on slot 3 while 'notApplicable'
|
|
is displayed for slot 4."
|
|
::= { bladeDetailsEntry 4 }
|
|
|
|
bladeDetailsMaximumClockRate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Module Details Table Maximum CPU Clock Rate applies to DPM
|
|
blades only. It displays processor's maximum clock rate based
|
|
on sample interval. Note that some blades do not maximum
|
|
clock rate. In this case, 'notApplicable' will be displayed.
|
|
When a 1200W or 1400W power module is installed in the domain
|
|
the power management policy will not be applicable.
|
|
In addition the power consumption in this domain will not be monitored.
|
|
|
|
NOTE: The maximum clock rate are reported only on a primary slot when
|
|
a server blade spans multiple slots (e.g. double wide or
|
|
triple wide). For example if the blade is double wide and
|
|
is installed in slot 3 and 4. 3 is primary slot while 4 is not.
|
|
The maximum clock rate are reported on slot 3 while 'notApplicable'
|
|
is displayed for slot 4."
|
|
::= { bladeDetailsEntry 5 }
|
|
|
|
bladeDetailsPowerSaverMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, the static low power saver mode allows the blade to selectively
|
|
alter its operating voltage and frequency to reduce power consumption.
|
|
This feature is not available on all blade types. Please refer to the blade documentation for details.
|
|
If a blade does not support the static low power saver mode, this object will return notApplicable (255).
|
|
|
|
Under certain rare circumstances, the enabling of the static low power saver mode
|
|
may not complete successfully due to interactions with other
|
|
blade functions, such as BIOS. Therefore, it is highly recommended that
|
|
the user perform a GET of this object after performing a SET, in order
|
|
to verify the completion of the intended operation.
|
|
|
|
NOTE: enabling this object will disable bladeDetailsDynamicPowerSaver if its not already disabled."
|
|
::= { bladeDetailsEntry 6 }
|
|
|
|
bladeDetailsDynamicPowerSaver OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, Dynamic Power Saver allows the voltage and frequency of the CPUs on the blade
|
|
to be controlled based on how busy the CPU is. This feature is not available on all blade types.
|
|
Please refer to the blade documentation for details. If a blade does not support the dynamic power
|
|
saver, this object will return notApplicable (255).
|
|
|
|
Under certain rare circumstances, the enabling of the dynamic power saver may not complete
|
|
successfully due to interactions with other blade functions, such as BIOS. Therefore, it is
|
|
highly recommended that the user perform a GET of this object after performing a SET, in order
|
|
to verify the completion of the intended operation.
|
|
|
|
NOTE: enabling this object will disable bladeDetailsPowerSaverMode if its not already disabled."
|
|
::= { bladeDetailsEntry 7 }
|
|
|
|
bladeDetailsDynamicPowerFavorPerformanceOverPower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When enabled, Dynamic Power Favor Performance Over Power supports a max performance mode that pushes the
|
|
system past its nominal CPU frequency when CPU and memory utilization implies it would help and the
|
|
system allows it. Dynamic Power Performance Over Power can be active on the blade only after Dynamic
|
|
Power Saver is enabled. This feature is not available on all blade types. Please refer to the
|
|
blade documentation for details. If a blade does not support the dynamic power saver, this object
|
|
will return notApplicable (255).
|
|
|
|
Under certain rare circumstances, the enabling of the dynamic power favor performance over power
|
|
may not complete successfully due to interactions with other blade functions, such as BIOS.
|
|
Therefore, it is highly recommended that the user perform a GET of this object after performing a SET,
|
|
in order to verify the completion of the intended operation."
|
|
::= { bladeDetailsEntry 8 }
|
|
|
|
bladeDetailsPowerControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
measurement(1),
|
|
measurementpcap(2),
|
|
psave(3),
|
|
measurementpsave(4),
|
|
measurementpcappsave(5),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is used to get or set the power control setting on a blade.
|
|
|
|
If dynamic power mgmt is not supported on a blade, notApplicable(255) will be returned.
|
|
|
|
This will set the power control setting on all slots of the multiwide blade. The
|
|
same can be used if the blade is single wide."
|
|
::= { bladeDetailsEntry 9 }
|
|
|
|
bladePowerTrending OBJECT IDENTIFIER ::= { bladeDetails 3 }
|
|
|
|
bladePowerTrendingPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lastHour(0),
|
|
last6Hours(1),
|
|
last12Hours(2),
|
|
last24Hours(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specify time period for blade module power trending information table view.
|
|
|
|
NOTE: This time period should be configured before displaying the
|
|
following Power Trending Information table for Blade Module."
|
|
::= { bladePowerTrending 1 }
|
|
|
|
bladePowerTrendingBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Module Power Trending Blade Id.
|
|
|
|
NOTE: The Blade Id should be configured before displaying the
|
|
bladePowerTrendingTable."
|
|
::= { bladePowerTrending 2 }
|
|
|
|
bladePowerTrendingSampleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladePowerTrendingSampleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Blade Module Power Trending Information."
|
|
::= { bladePowerTrending 10 }
|
|
|
|
bladePowerTrendingSampleEntry OBJECT-TYPE
|
|
SYNTAX BladePowerTrendingSampleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Module Power Trending Sample entry."
|
|
INDEX { bladePowerTrendingSampleIndex }
|
|
::= { bladePowerTrendingSampleTable 1 }
|
|
|
|
BladePowerTrendingSampleEntry ::= SEQUENCE {
|
|
bladePowerTrendingSampleIndex INTEGER,
|
|
bladePowerTrendingSampleId INTEGER,
|
|
bladePowerTrendingSampleTimeStamp OCTET STRING,
|
|
bladePowerTrendingSampleMax OCTET STRING,
|
|
bladePowerTrendingSampleMin OCTET STRING,
|
|
bladePowerTrendingSampleAve OCTET STRING
|
|
}
|
|
|
|
bladePowerTrendingSampleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Module Power Trending Sample Table Index."
|
|
::= { bladePowerTrendingSampleEntry 1 }
|
|
|
|
bladePowerTrendingSampleId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Module Power Trending Sample Table Blade Id."
|
|
::= { bladePowerTrendingSampleEntry 2 }
|
|
|
|
bladePowerTrendingSampleTimeStamp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Module Power Trending Sample Table Timestamp."
|
|
::= { bladePowerTrendingSampleEntry 3 }
|
|
|
|
bladePowerTrendingSampleMax OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Module Power Trending Sample Table Maximum Power."
|
|
::= { bladePowerTrendingSampleEntry 4 }
|
|
|
|
bladePowerTrendingSampleMin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Module Power Trending Sample Table Minimum Power."
|
|
::= { bladePowerTrendingSampleEntry 5 }
|
|
|
|
bladePowerTrendingSampleAve OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Module Power Trending Sample Table Average Power."
|
|
::= { bladePowerTrendingSampleEntry 6 }
|
|
|
|
|
|
switchDetails OBJECT IDENTIFIER ::= { moduleInformation 2 }
|
|
|
|
switchPowerTrending OBJECT IDENTIFIER ::= { switchDetails 3 }
|
|
|
|
switchPowerTrendingPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lastHour(0),
|
|
last6Hours(1),
|
|
last12Hours(2),
|
|
last24Hours(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specify time period for switch module power trending information table view.
|
|
|
|
NOTE: This time period should be configured before displaying the
|
|
following Power Trending Information table for Switch Module."
|
|
::= { switchPowerTrending 1 }
|
|
|
|
switchPowerTrendingSwitchId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module Power Trending Switch Id.
|
|
|
|
NOTE: The Switch Id should be configured before displaying the
|
|
switchPowerTrendingTable."
|
|
::= { switchPowerTrending 2 }
|
|
|
|
switchPowerTrendingSampleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwitchPowerTrendingSampleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Switch Module Power Trending Information."
|
|
::= { switchPowerTrending 10 }
|
|
|
|
switchPowerTrendingSampleEntry OBJECT-TYPE
|
|
SYNTAX SwitchPowerTrendingSampleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module Power Trending Sample entry."
|
|
INDEX { switchPowerTrendingSampleIndex }
|
|
::= { switchPowerTrendingSampleTable 1 }
|
|
|
|
SwitchPowerTrendingSampleEntry ::= SEQUENCE {
|
|
switchPowerTrendingSampleIndex INTEGER,
|
|
switchPowerTrendingSampleId INTEGER,
|
|
switchPowerTrendingSampleTimeStamp OCTET STRING,
|
|
switchPowerTrendingSampleMax OCTET STRING,
|
|
switchPowerTrendingSampleMin OCTET STRING,
|
|
switchPowerTrendingSampleAve OCTET STRING
|
|
}
|
|
|
|
switchPowerTrendingSampleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module Power Trending Sample Table Index."
|
|
::= { switchPowerTrendingSampleEntry 1 }
|
|
|
|
switchPowerTrendingSampleId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module Power Trending Sample Table Switch Id."
|
|
::= { switchPowerTrendingSampleEntry 2 }
|
|
|
|
switchPowerTrendingSampleTimeStamp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module Power Trending Sample Table Timestamp."
|
|
::= { switchPowerTrendingSampleEntry 3 }
|
|
|
|
switchPowerTrendingSampleMax OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module Power Trending Sample Table Maximum Power."
|
|
::= { switchPowerTrendingSampleEntry 4 }
|
|
|
|
switchPowerTrendingSampleMin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module Power Trending Sample Table Minimum Power."
|
|
::= { switchPowerTrendingSampleEntry 5 }
|
|
|
|
switchPowerTrendingSampleAve OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module Power Trending Sample Table Average Power."
|
|
::= { switchPowerTrendingSampleEntry 6 }
|
|
|
|
|
|
blowerDetails OBJECT IDENTIFIER ::= { moduleInformation 3 }
|
|
|
|
blowerPowerTrending OBJECT IDENTIFIER ::= { blowerDetails 3 }
|
|
|
|
blowerPowerTrendingPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lastHour(0),
|
|
last6Hours(1),
|
|
last12Hours(2),
|
|
last24Hours(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specify time period for blower module power trending information table view.
|
|
|
|
NOTE: This time period should be configured before displaying the
|
|
following Power Trending Information table for Blower Module.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowerPowerTrending 1 }
|
|
|
|
blowerPowerTrendingBlowerId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blower1(1),
|
|
blower2(2),
|
|
blower3(3),
|
|
blower4(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower Module Power Trending Blower Id.
|
|
|
|
NOTE: The Blower Id should be configured before displaying the blowerPowerTrendingTable.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowerPowerTrending 2 }
|
|
|
|
blowerPowerTrendingSampleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BlowerPowerTrendingSampleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Blower Module Power Trending Information.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowerPowerTrending 10 }
|
|
|
|
blowerPowerTrendingSampleEntry OBJECT-TYPE
|
|
SYNTAX BlowerPowerTrendingSampleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower Module Power Trending Sample entry."
|
|
INDEX { blowerPowerTrendingSampleIndex }
|
|
::= { blowerPowerTrendingSampleTable 1 }
|
|
|
|
BlowerPowerTrendingSampleEntry ::= SEQUENCE {
|
|
blowerPowerTrendingSampleIndex INTEGER,
|
|
blowerPowerTrendingSampleId INTEGER,
|
|
blowerPowerTrendingSampleTimeStamp OCTET STRING,
|
|
blowerPowerTrendingSampleMax OCTET STRING,
|
|
blowerPowerTrendingSampleMin OCTET STRING,
|
|
blowerPowerTrendingSampleAve OCTET STRING
|
|
}
|
|
|
|
blowerPowerTrendingSampleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower Module Power Trending Sample Table Index."
|
|
::= { blowerPowerTrendingSampleEntry 1 }
|
|
|
|
blowerPowerTrendingSampleId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blower1(1),
|
|
blower2(2),
|
|
blower3(3),
|
|
blower4(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower Module Power Trending Sample Table Blower Id."
|
|
::= { blowerPowerTrendingSampleEntry 2 }
|
|
|
|
blowerPowerTrendingSampleTimeStamp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower Module Power Trending Sample Table Timestamp."
|
|
::= { blowerPowerTrendingSampleEntry 3 }
|
|
|
|
blowerPowerTrendingSampleMax OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower Module Power Trending Sample Table Maximum Power."
|
|
::= { blowerPowerTrendingSampleEntry 4 }
|
|
|
|
blowerPowerTrendingSampleMin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower Module Power Trending Sample Table Minimum Power."
|
|
::= { blowerPowerTrendingSampleEntry 5 }
|
|
|
|
blowerPowerTrendingSampleAve OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower Module Power Trending Sample Table Average Power."
|
|
::= { blowerPowerTrendingSampleEntry 6 }
|
|
|
|
-- ******************************************************************************
|
|
-- Chassis Global Information
|
|
-- ******************************************************************************
|
|
|
|
chassisInformation OBJECT IDENTIFIER ::= { fuelGauge 5 }
|
|
|
|
chassisConfiguration OBJECT IDENTIFIER ::= { chassisInformation 1 }
|
|
|
|
chassisTotalDCPowerAvailable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis total DC power available, which displays the total DC power available
|
|
for the entire chassis. It is the sum of the two power domains."
|
|
::= { chassisConfiguration 1 }
|
|
|
|
chassisTotalACPowerInUsed OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis total AC power being used, which displays the total AC power
|
|
being consumed by all modules in the chassis. It also includes power
|
|
consumed by the blowers (chassis oooling devices) for the chassis."
|
|
::= { chassisConfiguration 2 }
|
|
|
|
chassisTotalThermalOutput OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis total thermal output, which displays the thermal output
|
|
(load) in BTUs per hour. It is calculated based on the total AC
|
|
power in use. (1 Watt = 3.412 BTU/hour)."
|
|
::= { chassisConfiguration 3 }
|
|
|
|
chassisTrendingSampleInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis Power and Thermal Trending Sample Interval.
|
|
0 means no trending. the minimum interval is 10 minutes and the maximum
|
|
is 60 minutes, in 5 minute increments."
|
|
::= { chassisConfiguration 4 }
|
|
|
|
chassisPowerService OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
volt110(1),
|
|
volt220(2),
|
|
notAvailable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The chassis power service mode.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { chassisConfiguration 5 }
|
|
|
|
-- ******************************************************************************
|
|
-- Chassis Power Trending Information
|
|
-- ******************************************************************************
|
|
chassisPowerTrending OBJECT IDENTIFIER ::= { chassisInformation 3 }
|
|
|
|
chassisPowerTrendingPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lastHour(0),
|
|
last6Hours(1),
|
|
last12Hours(2),
|
|
last24Hours(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specify time period of power trending information.
|
|
NOTE: This time period should be configured before displaying the
|
|
following Power Trending Information table for Chassis."
|
|
::= { chassisPowerTrending 1 }
|
|
|
|
chassisPowerTrendingSampleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ChassisPowerTrendingSampleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Chassis Power Trending Sample Information in specified time period."
|
|
::= { chassisPowerTrending 10 }
|
|
|
|
chassisPowerTrendingSampleEntry OBJECT-TYPE
|
|
SYNTAX ChassisPowerTrendingSampleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis Power Trending Sample entry in specified time period."
|
|
INDEX { chassisPowerTrendingSampleIndex }
|
|
::= { chassisPowerTrendingSampleTable 1 }
|
|
|
|
ChassisPowerTrendingSampleEntry ::= SEQUENCE {
|
|
chassisPowerTrendingSampleIndex INTEGER,
|
|
chassisPowerTrendingSampleTimeStamp OCTET STRING,
|
|
chassisPowerTrendingSampleAve OCTET STRING
|
|
}
|
|
|
|
chassisPowerTrendingSampleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis Power Trending Sample Index in specified time period."
|
|
::= { chassisPowerTrendingSampleEntry 1 }
|
|
|
|
chassisPowerTrendingSampleTimeStamp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis Power Trending Sample Timestamp in specified time period."
|
|
::= { chassisPowerTrendingSampleEntry 2 }
|
|
|
|
chassisPowerTrendingSampleAve OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis Power Trending Sample Average Power in specified time period."
|
|
::= { chassisPowerTrendingSampleEntry 3 }
|
|
|
|
-- ******************************************************************************
|
|
-- Chassis Thermal Trending Information
|
|
-- ******************************************************************************
|
|
chassisThermalTrending OBJECT IDENTIFIER ::= { chassisInformation 5 }
|
|
|
|
chassisThermalTrendingPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lastHour(0),
|
|
last6Hours(1),
|
|
last12Hours(2),
|
|
last24Hours(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specify time period of thermal trending information.
|
|
NOTE: This time period should be configured before displaying the
|
|
following Thermal Trending Information table for Chassis."
|
|
::= { chassisThermalTrending 1 }
|
|
|
|
mt1ThermalTrendingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mt1ThermalTrendingEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Media Tray 1 Thermal Trending Information."
|
|
::= { chassisThermalTrending 10 }
|
|
|
|
mt1ThermalTrendingEntry OBJECT-TYPE
|
|
SYNTAX Mt1ThermalTrendingEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media Tray 1 Thermal Trending entry."
|
|
INDEX { mt1ThermalTrendingIndex }
|
|
::= { mt1ThermalTrendingTable 1 }
|
|
|
|
Mt1ThermalTrendingEntry ::= SEQUENCE {
|
|
mt1ThermalTrendingIndex INTEGER,
|
|
mt1ThermalTrendingTimeStamp OCTET STRING,
|
|
mt1ThermalTrendingTemperature OCTET STRING
|
|
}
|
|
|
|
mt1ThermalTrendingIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media Tray 1 Thermal Trending Table Index."
|
|
::= { mt1ThermalTrendingEntry 1 }
|
|
|
|
mt1ThermalTrendingTimeStamp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media Tray 1 Thermal Trending Table Sample Timestamp."
|
|
::= { mt1ThermalTrendingEntry 2 }
|
|
|
|
mt1ThermalTrendingTemperature OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media Tray 1 Thermal Trending Table Temperature."
|
|
::= { mt1ThermalTrendingEntry 3 }
|
|
|
|
mt2ThermalTrendingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mt2ThermalTrendingEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Media Tray 2 Thermal Trending Information.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { chassisThermalTrending 15 }
|
|
|
|
mt2ThermalTrendingEntry OBJECT-TYPE
|
|
SYNTAX Mt2ThermalTrendingEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media Tray 2 Thermal Trending entry.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
INDEX { mt2ThermalTrendingIndex }
|
|
::= { mt2ThermalTrendingTable 1 }
|
|
|
|
Mt2ThermalTrendingEntry ::= SEQUENCE {
|
|
mt2ThermalTrendingIndex INTEGER,
|
|
mt2ThermalTrendingTimeStamp OCTET STRING,
|
|
mt2ThermalTrendingTemperature OCTET STRING
|
|
}
|
|
|
|
mt2ThermalTrendingIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media Tray 2 Thermal Trending Table Index.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mt2ThermalTrendingEntry 1 }
|
|
|
|
mt2ThermalTrendingTimeStamp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media Tray 2 Thermal Trending Table Sample Timestamp.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mt2ThermalTrendingEntry 2 }
|
|
|
|
mt2ThermalTrendingTemperature OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media Tray 2 Thermal Trending Table Temperature.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mt2ThermalTrendingEntry 3 }
|
|
|
|
blower1ThermalTrendingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Blower1ThermalTrendingEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Blower 1 Thermal Trending Information.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { chassisThermalTrending 20}
|
|
|
|
blower1ThermalTrendingEntry OBJECT-TYPE
|
|
SYNTAX Blower1ThermalTrendingEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 1 Thermal Trending entry."
|
|
INDEX { blower1ThermalTrendingIndex }
|
|
::= { blower1ThermalTrendingTable 1 }
|
|
|
|
Blower1ThermalTrendingEntry ::= SEQUENCE {
|
|
blower1ThermalTrendingIndex INTEGER,
|
|
blower1ThermalTrendingTimeStamp OCTET STRING,
|
|
blower1ThermalTrendingTemperature OCTET STRING
|
|
}
|
|
|
|
blower1ThermalTrendingIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 1 Thermal Trending Table Index."
|
|
::= { blower1ThermalTrendingEntry 1 }
|
|
|
|
blower1ThermalTrendingTimeStamp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 1 Thermal Trending Table Sample Timestamp."
|
|
::= { blower1ThermalTrendingEntry 2 }
|
|
|
|
blower1ThermalTrendingTemperature OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 1 Thermal Trending Table Temperature."
|
|
::= { blower1ThermalTrendingEntry 3 }
|
|
|
|
blower2ThermalTrendingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Blower2ThermalTrendingEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Blower 2 Thermal Trending Information.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { chassisThermalTrending 30}
|
|
|
|
blower2ThermalTrendingEntry OBJECT-TYPE
|
|
SYNTAX Blower2ThermalTrendingEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower Thermal 2 Trending entry."
|
|
INDEX { blower2ThermalTrendingIndex }
|
|
::= { blower2ThermalTrendingTable 1 }
|
|
|
|
Blower2ThermalTrendingEntry ::= SEQUENCE {
|
|
blower2ThermalTrendingIndex INTEGER,
|
|
blower2ThermalTrendingTimeStamp OCTET STRING,
|
|
blower2ThermalTrendingTemperature OCTET STRING
|
|
}
|
|
|
|
blower2ThermalTrendingIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 2 Thermal Trending Table Index."
|
|
::= { blower2ThermalTrendingEntry 1 }
|
|
|
|
blower2ThermalTrendingTimeStamp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 2 Thermal Trending Table Sample Timestamp."
|
|
::= { blower2ThermalTrendingEntry 2 }
|
|
|
|
blower2ThermalTrendingTemperature OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 2 Thermal Trending Table Temperature."
|
|
::= { blower2ThermalTrendingEntry 3 }
|
|
|
|
blower3ThermalTrendingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Blower3ThermalTrendingEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Blower 3 Thermal Trending Information.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { chassisThermalTrending 40}
|
|
|
|
blower3ThermalTrendingEntry OBJECT-TYPE
|
|
SYNTAX Blower3ThermalTrendingEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 3 Thermal Trending entry.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
INDEX { blower3ThermalTrendingIndex }
|
|
::= { blower3ThermalTrendingTable 1 }
|
|
|
|
Blower3ThermalTrendingEntry ::= SEQUENCE {
|
|
blower3ThermalTrendingIndex INTEGER,
|
|
blower3ThermalTrendingTimeStamp OCTET STRING,
|
|
blower3ThermalTrendingTemperature OCTET STRING
|
|
}
|
|
|
|
blower3ThermalTrendingIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 3 Thermal Trending Table Index.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
::= { blower3ThermalTrendingEntry 1 }
|
|
|
|
blower3ThermalTrendingTimeStamp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 3 Thermal Trending Table Sample Timestamp.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
::= { blower3ThermalTrendingEntry 2 }
|
|
|
|
blower3ThermalTrendingTemperature OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 3 Thermal Trending Table Temperature.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
::= { blower3ThermalTrendingEntry 3 }
|
|
|
|
blower4ThermalTrendingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Blower4ThermalTrendingEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Blower 4 Thermal Trending Information.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
::= { chassisThermalTrending 50}
|
|
|
|
blower4ThermalTrendingEntry OBJECT-TYPE
|
|
SYNTAX Blower4ThermalTrendingEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 4 Thermal Trending entry.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only.
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
INDEX { blower4ThermalTrendingIndex }
|
|
::= { blower4ThermalTrendingTable 1 }
|
|
|
|
Blower4ThermalTrendingEntry ::= SEQUENCE {
|
|
blower4ThermalTrendingIndex INTEGER,
|
|
blower4ThermalTrendingTimeStamp OCTET STRING,
|
|
blower4ThermalTrendingTemperature OCTET STRING
|
|
}
|
|
|
|
blower4ThermalTrendingIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 4 Thermal Trending Table Index.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
::= { blower4ThermalTrendingEntry 1 }
|
|
|
|
blower4ThermalTrendingTimeStamp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 4 Thermal Trending Table Sample Timestamp.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
::= { blower4ThermalTrendingEntry 2 }
|
|
|
|
blower4ThermalTrendingTemperature OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower 4 Thermal Trending Table Temperature.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
::= { blower4ThermalTrendingEntry 3 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Power Policy Table
|
|
-- ********************************************************************************
|
|
powerPolicyInformation OBJECT IDENTIFIER ::= { fuelGauge 6 }
|
|
|
|
powerPolicyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PowerPolicyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Power Policy information for all power domains. Reading this
|
|
table can tell you about the available power policies that can be
|
|
configured for a domain and also which is currently selected. The
|
|
powerPolicyActivate object can also be SET to select which policy
|
|
should be active for a given power domain."
|
|
::= { powerPolicyInformation 1 }
|
|
|
|
powerPolicyEntry OBJECT-TYPE
|
|
SYNTAX PowerPolicyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Policy Entry"
|
|
INDEX { powerPolicyIndex }
|
|
::= { powerPolicyTable 1 }
|
|
|
|
PowerPolicyEntry ::= SEQUENCE {
|
|
powerPolicyIndex INTEGER,
|
|
powerPolicyPowerDomainNumber INTEGER,
|
|
powerPolicyName OCTET STRING,
|
|
powerPolicyPwrSupplyFailureLimit INTEGER,
|
|
powerPolicyMaxPowerLimit INTEGER,
|
|
powerPolicyEstimatedUtilization INTEGER,
|
|
powerPolicyActivate INTEGER
|
|
}
|
|
|
|
powerPolicyIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unique idenitifier of a row in the powerPolicyTable."
|
|
::= { powerPolicyEntry 1 }
|
|
|
|
powerPolicyPowerDomainNumber OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
powerDomain1(1),
|
|
powerDomain2(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power domain number which this row is associated with."
|
|
::= { powerPolicyEntry 2 }
|
|
|
|
powerPolicyName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The short name of the power policy. The following are the possible
|
|
names and their detailed description:
|
|
|
|
Power Module Redundancy
|
|
Intended for a single AC power source into the chassis
|
|
where each Power Module is on its own dedicated circuit.
|
|
Total allowed power draw is limited to one less than the
|
|
number of Power Modules when more than one Power Module is
|
|
present. One Power Module can fail without affecting blade
|
|
operation. Multiple Power Module failures can cause
|
|
the chassis to power off. Note that some blades may not be
|
|
allowed to power on if doing so would exceed the policy power
|
|
limit.
|
|
|
|
Power Module Redundancy with Blade Throttling Allowed
|
|
Very similar to the Power Module Redundancy policy. This
|
|
policy allows you to draw more total power; however, capable
|
|
blades may be allowed to throttle down if one Power Module fails.
|
|
|
|
Basic Power Management
|
|
Total allowed power is higher than other policies and is limited only
|
|
by the total power capacity of all the Power Modules up to the maximum
|
|
of chassis power rating. This is the least conservative approach, since
|
|
it does not provide any protection for AC power source or Power Module
|
|
failure. If any single power supply fails, blade and/or chassis
|
|
operation may be affected.
|
|
|
|
AC Power Source Redundancy
|
|
Intended for dual AC power sources into the chassis. Total
|
|
allowed power draw is limited to the capacity of two Power
|
|
Modules. This is the most conservative approach and is
|
|
recommended when all four Power Modules are installed.
|
|
When the chassis is correctly wired with dual AC power
|
|
sources, one AC power source can fail without affecting
|
|
blade operation. Note that some blades may not be
|
|
allowed to power on if doing so would exceed the policy
|
|
power limit.
|
|
|
|
AC Power Source Redundancy with Blade Throttling Allowed
|
|
Very similar to the AC Power Source Redundancy policy. This policy
|
|
allows you to draw more total power; however, capable blades
|
|
may be allowed to throttle down if one AC power source fails."
|
|
::= { powerPolicyEntry 3 }
|
|
|
|
powerPolicyPwrSupplyFailureLimit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of power supplies that can fail in a chassis
|
|
while still providing redundancy."
|
|
::= { powerPolicyEntry 4 }
|
|
|
|
powerPolicyMaxPowerLimit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum power available (in watts), based on the number of power modules and
|
|
the Power Management Policy setting."
|
|
::= { powerPolicyEntry 5 }
|
|
|
|
powerPolicyEstimatedUtilization OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The estimated utilization (as a percentage) based on current power usage."
|
|
::= { powerPolicyEntry 6 }
|
|
|
|
powerPolicyActivate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When read, this object provides the status of this power policy. If the
|
|
value is enabled(1), it means this is the active power policy for the
|
|
associated domain. When set to a value of enabled(1), the power policy
|
|
will be made the active one for the associated domain. A set of disabled(0)
|
|
is not allowed.
|
|
|
|
The SET may fail when the user goes from a less restrictive policy
|
|
to a more restrictive policy, e.g. no power management to redundant power
|
|
modules.
|
|
|
|
This happens because the AMM might have allocated more power for components
|
|
in the less restrictive policy. Then if a user wants to go to a more restrictive
|
|
policy, the power available may be lower than what was already allocated.
|
|
|
|
The SET should always succeed if a user goes from a more restrictive to
|
|
a less restrictive policy."
|
|
::= { powerPolicyEntry 7 }
|
|
|
|
-- ********************************************************************************
|
|
-- Error logs
|
|
-- ********************************************************************************
|
|
eventLog OBJECT IDENTIFIER ::= { errorLogs 4 }
|
|
|
|
readEventLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ReadEventLogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of event log entry information."
|
|
::= { eventLog 2 }
|
|
|
|
readEventLogEntry OBJECT-TYPE
|
|
SYNTAX ReadEventLogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Event log table entry"
|
|
INDEX { readEventLogIndex }
|
|
::= { readEventLogTable 1 }
|
|
|
|
|
|
ReadEventLogEntry ::= SEQUENCE {
|
|
readEventLogIndex INTEGER,
|
|
readEventLogString OCTET STRING
|
|
}
|
|
|
|
|
|
readEventLogIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The event log index number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { readEventLogEntry 1 }
|
|
|
|
readEventLogString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string of data detailing an event.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { readEventLogEntry 2 }
|
|
|
|
|
|
|
|
clearEventLog OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clear the event log.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this
|
|
MIB object."
|
|
::= { eventLog 3 }
|
|
|
|
monitorLogStateEvents OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If disabled, it means the info LED will not turn on when the log gets full
|
|
and no alerts will be sent out. If enabled, the LED will turn on when the log
|
|
gets full and alerts will be sent out."
|
|
::= { eventLog 4 }
|
|
|
|
readEnhancedEventLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ReadEnhancedEventLogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of enhanced event log entry information."
|
|
::= { eventLog 6 }
|
|
|
|
readEnhancedEventLogEntry OBJECT-TYPE
|
|
SYNTAX ReadEnhancedEventLogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enhaced Event log table entry, new entries could be added for new items."
|
|
INDEX { readEnhancedEventLogNumber }
|
|
::= { readEnhancedEventLogTable 1 }
|
|
|
|
ReadEnhancedEventLogEntry ::= SEQUENCE {
|
|
readEnhancedEventLogNumber INTEGER,
|
|
readEnhancedEventLogAttribute OCTET STRING,
|
|
readEnhancedEventLogMessage OCTET STRING
|
|
}
|
|
|
|
readEnhancedEventLogNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The event log number for the enhanced event log.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { readEnhancedEventLogEntry 1 }
|
|
|
|
readEnhancedEventLogAttribute OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string of data detailing an event log's attribute, such as the
|
|
Event ID and Call Home Flag. The Event ID is a hexadecimal number representing an specific or class of events.
|
|
The call home flag indicates that the corresponding problem may result in a call home.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { readEnhancedEventLogEntry 2}
|
|
readEnhancedEventLogMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string of data detailing an event log message.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { readEnhancedEventLogEntry 3}
|
|
|
|
readAuditLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ReadAuditLogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of audit log entry information. Audit log includes the logs whose source is 'Audit'"
|
|
::= { eventLog 10 }
|
|
|
|
readAuditLogEntry OBJECT-TYPE
|
|
SYNTAX ReadAuditLogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Audit log table entry, new entries could be added for new items."
|
|
INDEX { readAuditLogNumber }
|
|
::= { readAuditLogTable 1 }
|
|
|
|
|
|
ReadAuditLogEntry ::= SEQUENCE {
|
|
readAuditLogNumber INTEGER,
|
|
readAuditLogAttribute OCTET STRING,
|
|
readAuditLogMessage OCTET STRING
|
|
}
|
|
|
|
|
|
readAuditLogNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The audit log number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { readAuditLogEntry 1 }
|
|
|
|
readAuditLogAttribute OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string of data detailing an audit eventlog's attribute.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { readAuditLogEntry 2 }
|
|
readAuditLogMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string of data detailing an audit event log message.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { readAuditLogEntry 3 }
|
|
|
|
clearAuditLog OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clear the audit log.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this
|
|
MIB object."
|
|
::= { eventLog 11 }
|
|
|
|
readSystemLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ReadSystemLogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of system log entry information. System log includes the logs whose source is other than 'Audit'"
|
|
::= { eventLog 12 }
|
|
|
|
readSystemLogEntry OBJECT-TYPE
|
|
SYNTAX ReadSystemLogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System log table entry, new entries could be added for new items."
|
|
INDEX { readSystemLogNumber }
|
|
::= { readSystemLogTable 1 }
|
|
|
|
|
|
ReadSystemLogEntry ::= SEQUENCE {
|
|
readSystemLogNumber INTEGER,
|
|
readSystemLogAttribute OCTET STRING,
|
|
readSystemLogMessage OCTET STRING
|
|
}
|
|
|
|
|
|
readSystemLogNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system log index number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { readSystemLogEntry 1 }
|
|
|
|
readSystemLogAttribute OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string of data detailing an system event log's attribute.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { readSystemLogEntry 2 }
|
|
readSystemLogMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string of data detailing an system event log message.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { readSystemLogEntry 3 }
|
|
|
|
clearSystemLog OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clear the system log.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this
|
|
MIB object."
|
|
::= { eventLog 13 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Configure the MM
|
|
-- ********************************************************************************
|
|
-- ********************************************************************************
|
|
-- Remote Access Configuration
|
|
-- ********************************************************************************
|
|
remoteAccessConfig OBJECT IDENTIFIER ::= { configureSP 1 }
|
|
|
|
-- ********************************************************************************
|
|
-- General Remote Access and Remote Alerts Configuration
|
|
-- ********************************************************************************
|
|
generalRemoteCfg OBJECT IDENTIFIER ::= { remoteAccessConfig 1 }
|
|
|
|
remoteAlertRetryDelay OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noDelay(0), -- deprecated
|
|
oneHalfMinute(30),
|
|
oneMinute(60),
|
|
oneAndHalfMinutes(90),
|
|
twoMinutes(120),
|
|
twoAndHalfMinutes(150),
|
|
threeMinutes(180),
|
|
threeAndHalfMinutes(210),
|
|
fourMinutes(240)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number in seconds to delay between retries if sending a
|
|
remote alert is unsuccessful."
|
|
::= { generalRemoteCfg 3 }
|
|
|
|
remoteAlertRetryCount OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noretry(0),
|
|
retry1(1),
|
|
retry2(2),
|
|
retry3(3),
|
|
retry4(4),
|
|
retry5(5),
|
|
retry6(6),
|
|
retry7(7),
|
|
retry8(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of additional times a remote alert will be
|
|
retried if not successfully sent. A value of zero indicates
|
|
no retries will be attempted."
|
|
::= { generalRemoteCfg 4 }
|
|
|
|
remoteAlertEntryDelay OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noDelay(0),
|
|
oneHalfMinute(30),
|
|
oneMinute(60),
|
|
oneAndHalfMinutes(90),
|
|
twoMinutes(120),
|
|
twoAndHalfMinutes(150),
|
|
threeMinutes(180),
|
|
threeAndHalfMinutes(210),
|
|
fourMinutes(240)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Number in seconds to delay between entries if sending a
|
|
remote alert is unsuccessful.
|
|
|
|
NOTE: This object is no longer supported. However, for
|
|
compatibilities sake, a value of (255) is returned when
|
|
read. Also, write access has been removed."
|
|
::= { generalRemoteCfg 5 }
|
|
|
|
remoteAccessTamperDelay OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nowait(0),
|
|
oneMinute(1),
|
|
twoMinutes(2),
|
|
threeMinutes(3),
|
|
fourMinutes(4),
|
|
fiveMinutes(5),
|
|
sixMinutes(6),
|
|
sevenMinutes(7),
|
|
tenMinutes(10),
|
|
fifteenMinutes(15),
|
|
twentyMinutes(20),
|
|
thirtyMinutes(30),
|
|
sixtyMinutes(60),
|
|
oneTwentyMinutes(120),
|
|
oneEightyMinutes(180),
|
|
twoFortyMinutes(240)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This value is no longer supported and has been replaced by
|
|
'lockoutPeriod'."
|
|
::= { generalRemoteCfg 6 }
|
|
|
|
|
|
userAuthenticationMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
localOnly(0),
|
|
ldapOnly(1),
|
|
localFirstThenLdap(2),
|
|
ldapFirstThenLocal(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Use this field to specify how users attempting to login should be authenticated.
|
|
There are two methods:
|
|
Local authentication. Userid and password are verified by searching the list
|
|
of users locally configured under Local Login Profiles.
|
|
LDAP based authentication. Users are authenticated via a remote LDAP server.
|
|
One or both authentication methods can be selected. If both methods should be
|
|
used, the order must be specified."
|
|
::= { generalRemoteCfg 7 }
|
|
|
|
maxSessionsPerLDAPUser OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of simultaneous active sessions allowed for
|
|
each LDAP user. If the value is 0, this option is disabled. The
|
|
minimum value is 1 and the maximum value is 20."
|
|
::= { generalRemoteCfg 9 }
|
|
authenticationLoggingTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
logAll(0),
|
|
fiveSeconds(1),
|
|
thirtySeconds(2),
|
|
oneMinute(3),
|
|
fiveMinutes(4),
|
|
tenMinutes(5),
|
|
thirtyMinutes(6),
|
|
oneHour(7),
|
|
twelveHours(8),
|
|
oneDay(9),
|
|
logNone(255)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Use this option to set how long, in seconds, AMM will not log the authentication
|
|
events for the same user. The default setting is 5 minutes. 0 indicates log all
|
|
authentication events, 255 indicates don't log any new authentication events."
|
|
::= { generalRemoteCfg 10 }
|
|
trackingIP OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This option indicates tracking different IP addresses for the same user is
|
|
enabled or not. If it is enabled then an access every second from
|
|
alternating IP addresses will result in multiple log entries,
|
|
regardless of the time duration set in the 'authenticaionLoggingTimeout'field.
|
|
If this flag is disabled, multiple accesses by varying IP addresses
|
|
will only be logged as 'new' accesses if they are out of the
|
|
'authenticationLoggingTimeout'."
|
|
::= { generalRemoteCfg 11 }
|
|
|
|
-- ********************************************************************************
|
|
-- Account security management
|
|
-- ********************************************************************************
|
|
accountSecurityManagement OBJECT IDENTIFIER ::= { generalRemoteCfg 20 }
|
|
|
|
accountSecurityLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
legacy(0),
|
|
high(1),
|
|
custom(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The level of security needed for local user login passwords.
|
|
The legacy level:
|
|
- no password required
|
|
- no password expiration
|
|
- no password re-use restrictions
|
|
- no frequency of password change restrictions
|
|
- account is locked for 2 minutes after 5 login failures
|
|
- simple password rules
|
|
- no account inactivity monitoring
|
|
The high level:
|
|
- password required
|
|
- factory default 'USERID' account password must be changed on next login
|
|
- force user to change password on first login
|
|
- password expires in 90 days
|
|
- password re-use checking enabled (last 5 passwords kept in history)
|
|
- minimum 24 hours interval between password changes
|
|
- account is locked for 60 minutes after 5 login failures
|
|
- complex password rules with 2 degrees of difference from previous password
|
|
- alert on account inactivity after 120 days
|
|
- accounts disabled after 180 days of inactivity
|
|
The custom level:
|
|
- set the password settings individually under customSecuritySettings
|
|
The default value is legacy."
|
|
::= { accountSecurityManagement 1 }
|
|
|
|
|
|
customSecuritySettings OBJECT IDENTIFIER ::= { accountSecurityManagement 2 }
|
|
|
|
loginPasswordRequired OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If enabled, all users require a login password to access the AMM.
|
|
If disabled, empty password is allowed and complex password rules
|
|
will be disabled automatically.
|
|
The default value is disabled."
|
|
::= { customSecuritySettings 1 }
|
|
|
|
passwordExpirationPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of days before login passwords expire. The minimum
|
|
value is 1 day and the maximum value is 365 days. The default
|
|
value is 90 days. A value of 0 disables this option."
|
|
::= { customSecuritySettings 2 }
|
|
|
|
defaultAdminPasswordExpired OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If enabled, the factory default 'USERID' account password must
|
|
be changed on next login. The default value is disabled."
|
|
::= { customSecuritySettings 3 }
|
|
|
|
minimumPasswordReuseCycle OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
onePassword(1),
|
|
twoPasswords(2),
|
|
threePasswords(3),
|
|
fourPasswords(4),
|
|
fivePasswords(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of unique passwords a user must choose before
|
|
reusing a password. The default value is none."
|
|
::= { customSecuritySettings 4 }
|
|
|
|
complexPasswordRules OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If enabled, the minimum complexity rules will be enforced for all
|
|
local login passwords and 'User login password required' rule will be enabled.
|
|
The rules are as follows:
|
|
Passwords must be a minimum of eight characters.
|
|
Passwords must not be a repeat or reverse of the associated login id.
|
|
Passwords must be no more than three of the same characters used consecutively.
|
|
Passwords must contain at least three of the following combinations:
|
|
At least one lower case alphanumeric character.
|
|
At least one upper case alphanumeric character.
|
|
At least one numeric character.
|
|
At least one special character.
|
|
The default value is disabled."
|
|
::= { customSecuritySettings 5 }
|
|
|
|
minimumDiffCharsPassword OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
oneChar(1),
|
|
twoChars(2),
|
|
threeChars(3),
|
|
fourChars(4),
|
|
fiveChars(5),
|
|
sixChars(6),
|
|
sevenChars(7),
|
|
eightChars(8),
|
|
nineChars(9),
|
|
tenChars(10),
|
|
elevenChars(11),
|
|
twelveChars(12),
|
|
thirteenChars(13),
|
|
fourteenChars(14),
|
|
fifteenChars(15)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The required minimum number of characters in the new password
|
|
different from the previous password. The default value is 2.
|
|
|
|
A SET of this object is ignored until the complexPasswordRules option is enabled
|
|
and the minimumPasswordReuseCycle is not none(0)"
|
|
::= { customSecuritySettings 6 }
|
|
|
|
changePasswordFirstAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If enabled, the login user will be forced to change their password on
|
|
the first access after the account has been established or on
|
|
the first access after an administrator has changed the password
|
|
for the user, except for the administrator password for USERID.
|
|
The default value is disabled."
|
|
::= { customSecuritySettings 7 }
|
|
|
|
inactivityAlertPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The period of time in days before generating an alert for a dormant
|
|
account. This value applies to all login accounts, including the
|
|
administrator account. The minimum value is 1 day and the maximum
|
|
value is 365 days. The default value is 0 which disables this option.
|
|
NOTE: This value must be less than the inactivityAlertDisablePeriod."
|
|
::= { customSecuritySettings 8 }
|
|
|
|
inactivityAlertDisablePeriod OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The period of time in days before generating an alert and disabling
|
|
a dormant account. This value applies to all login accounts, excluding
|
|
the administrator account. The minimum value is 1 day and the maximum
|
|
value is 365 days. The default value is 0 which disables this option.
|
|
NOTE: This value must be greater than the inactivityAlertPeriod."
|
|
::= { customSecuritySettings 9 }
|
|
|
|
lockoutPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The period of time in minutes that a user is locked out after the
|
|
maximum number of login failures was reached. The minimum value is
|
|
is 1 minute and the maximum value is 2880 minutes. The default value
|
|
is 2 minutes for the Legacy security level and 60 minutes for the
|
|
High security level. A value of 0 disables this option."
|
|
::= { customSecuritySettings 10 }
|
|
|
|
maxLoginFailures OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
oneTime(1),
|
|
twoTimes(2),
|
|
threeTimes(3),
|
|
fourTimes(4),
|
|
fiveTimes(5),
|
|
sixTimes(6),
|
|
sevenTimes(7),
|
|
eightTimes(8),
|
|
nineTimes(9),
|
|
tenTimes(10)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of login failures before a user account is locked.
|
|
A value of 0 disables this option. The default value is 5."
|
|
::= { customSecuritySettings 11 }
|
|
|
|
passwordChangeInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A minimum period of time that user is not able to change
|
|
their own password. The range of acceptable values will be
|
|
from 0 to 1440 (or 60 days). A value of 0 disables this
|
|
option. If the password expiration period is set, it must be
|
|
greater than the minimum password change interval."
|
|
::= { customSecuritySettings 12 }
|
|
|
|
-- ***********************************************************************
|
|
-- Serial Port Configuration
|
|
-- ***********************************************************************
|
|
serialPortCfg OBJECT IDENTIFIER ::= { remoteAccessConfig 2 }
|
|
|
|
portBaud OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
baud2400(0),
|
|
baud4800(1),
|
|
baud9600(3),
|
|
baud19200(7),
|
|
baud38400(15),
|
|
baud57600(23)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Baud rate for the serial port."
|
|
::= { serialPortCfg 1 }
|
|
|
|
portParity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
odd(1),
|
|
even(3),
|
|
mark(5),
|
|
space(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Parity setting for the serial port."
|
|
::= { serialPortCfg 2 }
|
|
|
|
portStopBits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
oneStopbit(0),
|
|
twoOrOnePtFive(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of stop bits for the serial port."
|
|
::= { serialPortCfg 3 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Remote Alert Profiles
|
|
-- ********************************************************************************
|
|
remoteAlertIds OBJECT IDENTIFIER ::= { remoteAccessConfig 3 }
|
|
|
|
remoteAlertIdsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RemoteAlertIdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of remote alert entries.
|
|
This table lets you configure remote alert recipients.
|
|
You can define up to 12 unique recipients.
|
|
NOTE: All selected alert events will be sent to all
|
|
enabled alert recipients."
|
|
::= { remoteAlertIds 1 }
|
|
|
|
remoteAlertIdsEntry OBJECT-TYPE
|
|
SYNTAX RemoteAlertIdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote alert entries."
|
|
INDEX { remoteAlertIdEntryIndex }
|
|
::= { remoteAlertIdsTable 1 }
|
|
|
|
|
|
RemoteAlertIdsEntry ::= SEQUENCE {
|
|
remoteAlertIdEntryIndex INTEGER,
|
|
remoteAlertIdEntryStatus INTEGER,
|
|
remoteAlertIdEntryIpOrHostAddress OCTET STRING,
|
|
remoteAlertIdEntryTextDescription OCTET STRING,
|
|
remoteAlertIdEntryNotificationType INTEGER,
|
|
remoteAlertIdEmailAddr OCTET STRING,
|
|
remoteAlertIdEntrySelectiveAlert INTEGER
|
|
}
|
|
|
|
|
|
remoteAlertIdEntryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for remote alert entry."
|
|
::= { remoteAlertIdsEntry 1 }
|
|
|
|
remoteAlertIdEntryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
invalid(0),
|
|
disabledAndValid(1),
|
|
enabledAndValid(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote alert entry status, invalid means entry
|
|
not defined yet, disabledAndValid means entry defined
|
|
but not enabled to send an alert, enabledAndValid means
|
|
entry defined and enabled to send an alert."
|
|
::= { remoteAlertIdsEntry 2 }
|
|
|
|
remoteAlertIdEntryIpOrHostAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..50))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A null terminated string that either
|
|
contains an IP address of the form '1.2.3.4'
|
|
or a host name (if DNS is enabled) for the
|
|
alert entry."
|
|
::= { remoteAlertIdsEntry 3 }
|
|
|
|
remoteAlertIdEntryTextDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..50))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A null terminated string that contains
|
|
a text description of this entry."
|
|
::= { remoteAlertIdsEntry 4 }
|
|
|
|
remoteAlertIdEntryNotificationType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
ibmDirectorOverLAN(8),
|
|
snmpOverLan(4),
|
|
emailOverLan(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote alert entry notification method. Types include
|
|
unknown when the type can't be determined (read-only),
|
|
ibmDirectorOverLAN for a LAN alert sent over ethernet to
|
|
IBM director, snmpOverLan for an SNMP alert over ethernet,
|
|
and emailOverLan for a E-Mail alert over ethernet."
|
|
::= { remoteAlertIdsEntry 5 }
|
|
|
|
remoteAlertIdEmailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A null terminated string that contains an
|
|
E-Mail Address. For example, 'jeb@us.ibm.com'.
|
|
Used only for an E-mail over LAN or E-Mail over PPP
|
|
notification type."
|
|
::= { remoteAlertIdsEntry 9 }
|
|
|
|
remoteAlertIdEntrySelectiveAlert OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
critOnlyAlerts(0),
|
|
allAlerts(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote alert entry selective alert setting. A value of
|
|
critOnlyAlerts will only send critical alerts to this
|
|
remote alert recipient, a value of allAlerts will send
|
|
all alerts to this remote alert recipient."
|
|
::= { remoteAlertIdsEntry 13 }
|
|
|
|
generateTestAlert OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate a Test Alert. This will send a test alert to all configured
|
|
and enabled remote alert recipients. The text portion of the alert
|
|
will contain 'Application Posted Alert to MM'.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this
|
|
MIB object."
|
|
::= { remoteAlertIds 30 }
|
|
|
|
-- ********************************************************************************
|
|
-- Remote Access Profiles
|
|
-- ********************************************************************************
|
|
remoteAccessIds OBJECT IDENTIFIER ::= { remoteAccessConfig 4 }
|
|
|
|
remoteAccessIdsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RemoteAccessIdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of remote access profiles.
|
|
|
|
This table lets you to configure all login profiles.
|
|
You can define up to 12 unique profiles.
|
|
|
|
NOTE: By default, the management module
|
|
comes configured with one login profile that allows remote
|
|
access using a login ID of 'USERID' and a password of 'PASSW0RD'
|
|
(the 0 is a zero). To avoid a potential security exposure,
|
|
we strongly recommend that you change this default Login
|
|
Profile to values of your choice."
|
|
::= { remoteAccessIds 1 }
|
|
|
|
remoteAccessIdsEntry OBJECT-TYPE
|
|
SYNTAX RemoteAccessIdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote access entries."
|
|
INDEX { remoteAccessIdEntryIndex }
|
|
::= { remoteAccessIdsTable 1 }
|
|
|
|
|
|
RemoteAccessIdsEntry ::= SEQUENCE {
|
|
remoteAccessIdEntryIndex INTEGER,
|
|
remoteAccessIdEntryUserId OCTET STRING,
|
|
remoteAccessIdEntryPassword OCTET STRING,
|
|
remoteAccessIdEntryEncodedLoginPw OCTET STRING,
|
|
remoteAccessIdEntryRole OCTET STRING,
|
|
remoteAccessIdEntryLoggedIn INTEGER,
|
|
remoteAccessIdEntryLastLogin OCTET STRING,
|
|
remoteAccessIdEntryPwdCompliant INTEGER,
|
|
remoteAccessIdEntryPwdExp OCTET STRING,
|
|
remoteAccessIdEntryDormant INTEGER,
|
|
remoteAccessIdEntryState INTEGER,
|
|
remoteAccessIdEntryAction INTEGER,
|
|
remoteAccessIdEntrySessionCount INTEGER,
|
|
remoteAccessIdEntryMaxSessions INTEGER
|
|
}
|
|
|
|
|
|
remoteAccessIdEntryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for Remote access entry."
|
|
::= { remoteAccessIdsEntry 1 }
|
|
|
|
remoteAccessIdEntryUserId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..15))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote access entry null terminated string that
|
|
contains the user-id. It must not be a duplicate of
|
|
any previously configured ones."
|
|
::= { remoteAccessIdsEntry 2 }
|
|
|
|
remoteAccessIdEntryPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..15))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote access password. The password must
|
|
contain at least one alphabetic and one
|
|
non-alphabetic character and be at least 5
|
|
characters long, or you can leave the password
|
|
field blank to set an empty password.
|
|
|
|
NOTE: Value returned by the GET command is meaningless
|
|
for this MIB object."
|
|
::= { remoteAccessIdsEntry 3 }
|
|
|
|
remoteAccessIdEntryEncodedLoginPw OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..36))
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Used only for configuration save/restore.
|
|
A null terminated string containing an encoded
|
|
concatenation of the login ID and password
|
|
separated by an ':'.
|
|
|
|
This object is no longer supported and will return
|
|
a string of asterisks"
|
|
::= { remoteAccessIdsEntry 7 }
|
|
|
|
remoteAccessIdEntryRole OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates if user has supervisor, operator, or custom access."
|
|
::= { remoteAccessIdsEntry 10 }
|
|
|
|
remoteAccessIdEntryLoggedIn OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates if user is currently logged in or not."
|
|
::= { remoteAccessIdsEntry 11 }
|
|
|
|
remoteAccessIdEntryLastLogin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Timestamp for the last successful login by the user."
|
|
::= { remoteAccessIdsEntry 12 }
|
|
|
|
remoteAccessIdEntryPwdCompliant OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates if user complies with all of the password
|
|
rules currently in effect."
|
|
::= { remoteAccessIdsEntry 13 }
|
|
|
|
remoteAccessIdEntryPwdExp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of days until the user's current password expires."
|
|
::= { remoteAccessIdsEntry 14 }
|
|
|
|
remoteAccessIdEntryDormant OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates if the user account has been inactive for a
|
|
specified amount of time based on inactivityAlertDisablePeriod
|
|
in the customSecuritySettings section."
|
|
::= { remoteAccessIdsEntry 15 }
|
|
|
|
remoteAccessIdEntryState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
active(1),
|
|
locked(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the state of the user:
|
|
Active - normal state
|
|
Disabled - user cannot use account until enabled by a
|
|
supervisor or chassis user account manager. An account
|
|
can get disabled after being dormant for a specified
|
|
amount of time OR as a result of a supervisor or chassis
|
|
user account manager disabling it.
|
|
Locked - account is temporarily locked due to repeated
|
|
unsuccessful login attempts as specified by lockoutPeriod
|
|
in the customSecuritySettings section. Account can be
|
|
unlocked by a supervisor or chassis user account manager
|
|
OR can be automatically unlocked after the lockoutPeriod expires.
|
|
|
|
NOTE: The disable action does not apply to supervisor or chassis
|
|
user account manager accounts."
|
|
::= { remoteAccessIdsEntry 16 }
|
|
|
|
remoteAccessIdEntryAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1),
|
|
unlock(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Actions that only a supervisor or chassis user account manager
|
|
can perform for each user id:
|
|
Enable - enables an account in the Disabled state
|
|
Disable - disables an account in the Active or Locked state
|
|
Unlock - unlock an account in the Locked state
|
|
|
|
NOTE: The disable action does not apply to supervisor or chassis
|
|
user account manager accounts.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this
|
|
MIB object."
|
|
::= { remoteAccessIdsEntry 17 }
|
|
|
|
remoteAccessIdEntrySessionCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of sessions the user is currently logged in to."
|
|
::= { remoteAccessIdsEntry 18 }
|
|
|
|
remoteAccessIdEntryMaxSessions OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of simultaneous active sessions allowed for
|
|
the user. If the value is 0, this option is disabled. The
|
|
minimum value is 1 and the maximum value is 20."
|
|
::= { remoteAccessIdsEntry 19 }
|
|
|
|
-- ********************************************************************************
|
|
|
|
remoteAccessUserAuthorityLevelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RemoteAccessUserAuthorityLevelEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of user authority level profiles."
|
|
::= { remoteAccessIds 2 }
|
|
|
|
remoteAccessUserAuthorityLevelEntry OBJECT-TYPE
|
|
SYNTAX RemoteAccessUserAuthorityLevelEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User authority level entries."
|
|
INDEX { ualIndex }
|
|
::= { remoteAccessUserAuthorityLevelTable 1 }
|
|
|
|
RemoteAccessUserAuthorityLevelEntry ::= SEQUENCE {
|
|
ualIndex INTEGER,
|
|
ualId OCTET STRING,
|
|
ualSupervisor INTEGER,
|
|
ualReadOnly INTEGER,
|
|
ualAccountManagement INTEGER,
|
|
ualConsoleAccess INTEGER,
|
|
ualConsoleAndVirtualMediaAccess INTEGER,
|
|
ualServerPowerAccess INTEGER,
|
|
ualAllowClearLog INTEGER,
|
|
ualAdapterBasicConfig INTEGER,
|
|
ualAdapterNetworkAndSecurityConfig INTEGER,
|
|
ualAdapterAdvancedConfig INTEGER
|
|
}
|
|
|
|
ualIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for User Authority Level entry."
|
|
::= { remoteAccessUserAuthorityLevelEntry 1 }
|
|
|
|
ualId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User ID"
|
|
::= { remoteAccessUserAuthorityLevelEntry 2 }
|
|
|
|
ualSupervisor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has no restrictions."
|
|
::= { remoteAccessUserAuthorityLevelEntry 3 }
|
|
|
|
ualReadOnly OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has only read-only access, and cannot perform any save, modify,
|
|
clear, or state affecting operations (e.g. restart MM, restore defaults,
|
|
upgrade the firmware, etc.)."
|
|
::= { remoteAccessUserAuthorityLevelEntry 4 }
|
|
|
|
ualAccountManagement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can add/modify/delete users and change the global login settings in
|
|
the Login Profiles panel."
|
|
::= { remoteAccessUserAuthorityLevelEntry 5 }
|
|
|
|
ualConsoleAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can access the remote console."
|
|
::= { remoteAccessUserAuthorityLevelEntry 6 }
|
|
|
|
ualConsoleAndVirtualMediaAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can access both the remote console and the virtual media feature."
|
|
::= { remoteAccessUserAuthorityLevelEntry 7 }
|
|
|
|
ualServerPowerAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can access the power on and restart functions for the remote server.
|
|
These functions are available via the Power/Restart panel."
|
|
::= { remoteAccessUserAuthorityLevelEntry 8 }
|
|
|
|
ualAllowClearLog OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can clear the event logs. Everyone can look at the
|
|
event logs, but this particular permission is required to clear the logs."
|
|
::= { remoteAccessUserAuthorityLevelEntry 9 }
|
|
|
|
ualAdapterBasicConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can modify configuration parameters in the System Settings and Alerts
|
|
panels."
|
|
::= { remoteAccessUserAuthorityLevelEntry 10 }
|
|
|
|
ualAdapterNetworkAndSecurityConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can modify configuration parameters in the Security, Network Protocols,
|
|
Network Interface, Port Assignments, and Serial Port panels."
|
|
::= { remoteAccessUserAuthorityLevelEntry 11 }
|
|
|
|
ualAdapterAdvancedConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has no restrictions when configuring the adapter. In addition, the
|
|
user is said to have administrative access to the RSA, meaning that the
|
|
user can also perform the following advanced functions: firmware upgrades,
|
|
PXE network boot, restore adapter factory defaults, modify and restore
|
|
adapter configuration from a configuration file, and restart/reset the
|
|
adapter."
|
|
::= { remoteAccessUserAuthorityLevelEntry 12 }
|
|
|
|
|
|
remoteAccessRBSroleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RemoteAccessRBSroleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of RBS User Role profiles."
|
|
::= { remoteAccessIds 3 }
|
|
|
|
remoteAccessRBSroleEntry OBJECT-TYPE
|
|
SYNTAX RemoteAccessRBSroleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User Role entries."
|
|
INDEX { roleIndex }
|
|
::= { remoteAccessRBSroleTable 1 }
|
|
|
|
RemoteAccessRBSroleEntry ::= SEQUENCE {
|
|
roleIndex INTEGER,
|
|
roleId OCTET STRING,
|
|
rbsSupervisor INTEGER,
|
|
rbsOperator INTEGER,
|
|
rbsChassisOperator INTEGER,
|
|
rbsChassisAccountManagement INTEGER,
|
|
rbsChassisLogManagement INTEGER,
|
|
rbsChassisConfiguration INTEGER,
|
|
rbsChassisAdministration INTEGER,
|
|
rbsBladeOperator INTEGER,
|
|
rbsBladeRemotePresence INTEGER,
|
|
rbsBladeConfiguration INTEGER,
|
|
rbsBladeAdministration INTEGER,
|
|
rbsSwitchModuleOperator INTEGER,
|
|
rbsSwitchModuleConfiguration INTEGER,
|
|
rbsSwitchModuleAdministration INTEGER,
|
|
rbsBladeRemotePresenseVideo INTEGER, -- deprecated
|
|
rbsBladeRemotePresenseKVM INTEGER, -- deprecated
|
|
rbsBladeRemotePresenseRdriveR INTEGER, -- deprecated
|
|
rbsBladeRemotePresenseRdriveRW INTEGER, -- deprecated
|
|
rbsChassisRemotePresenseRdoc INTEGER, -- deprecated
|
|
rbsRemotePresenceSupervisor INTEGER -- deprecated
|
|
}
|
|
|
|
|
|
roleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for RBS User Role entry."
|
|
::= { remoteAccessRBSroleEntry 1 }
|
|
|
|
roleId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User ID"
|
|
::= { remoteAccessRBSroleEntry 2 }
|
|
|
|
rbsSupervisor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has no restrictions."
|
|
::= { remoteAccessRBSroleEntry 3 }
|
|
|
|
rbsOperator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has read-only access, and cannot perform
|
|
any save, modify, clear, or state affecting operations
|
|
(e.g. restart MM, restore defaults, upgrade the firmware, etc.)."
|
|
::= { remoteAccessRBSroleEntry 4 }
|
|
|
|
rbsChassisOperator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has ability to browse status and properties of
|
|
chassis components (MM, blowers (chassis cooling devices), midplane, power modules,
|
|
media tray. Ability to backup MM configuration to a file.
|
|
Saving MM configuration to chassis requires supervisor access."
|
|
::= { remoteAccessRBSroleEntry 5 }
|
|
|
|
|
|
rbsChassisAccountManagement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can add/modify/delete user login profiles. Ability
|
|
to backup MM configuration to a file. Changing global login
|
|
settings require chassis configuration authority."
|
|
::= { remoteAccessRBSroleEntry 6 }
|
|
|
|
rbsChassisLogManagement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has ability to clear the MM event log, change log
|
|
policy settings, and backup MM configuration to a file."
|
|
::= { remoteAccessRBSroleEntry 7 }
|
|
|
|
rbsChassisConfiguration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can modify and save any chassis configuration
|
|
parameter (except user profiles and event log settings).
|
|
Ability to restore MM factory defaults if the user also has
|
|
chassis administration permissions. Ability to change the
|
|
global login settings, SOL configuration, and backup MM
|
|
configuration to a file."
|
|
::= { remoteAccessRBSroleEntry 8 }
|
|
|
|
rbsChassisAdministration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has ability to do MM firmware updates, modify chassis
|
|
LEDs, restore MM factory defaults if the user also has
|
|
chassis configuration permissions. Ability to restart MM
|
|
and backup MM configuration to a file."
|
|
::= { remoteAccessRBSroleEntry 9 }
|
|
|
|
rbsBladeOperator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has ability to browse status and properties of
|
|
blades."
|
|
::= { remoteAccessRBSroleEntry 10 }
|
|
|
|
rbsBladeRemotePresence OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has ability to access the Remote Control web panel
|
|
and the functions provided on the panel: remote console
|
|
(KVM) and remote disk. The ability to issue the CLI
|
|
console command to start an SOL session to a blade will
|
|
also require this authority."
|
|
::= { remoteAccessRBSroleEntry 11 }
|
|
|
|
rbsBladeConfiguration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can modify and save any blade configuration parameter."
|
|
::= { remoteAccessRBSroleEntry 12 }
|
|
|
|
rbsBladeAdministration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can power on/off and restart blades, activate
|
|
standby blades, do firmware updates, and modify blade LEDs."
|
|
::= { remoteAccessRBSroleEntry 13 }
|
|
|
|
rbsSwitchModuleOperator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has ability to browse status and properties of
|
|
I/O Modules, and to ping I/O Modules."
|
|
::= { remoteAccessRBSroleEntry 14 }
|
|
|
|
rbsSwitchModuleConfiguration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can modify the I/O Module IP address, configure
|
|
I/O Module Advanced Management parameters, and restore
|
|
factory defaults on an I/O Module. Note that a user
|
|
requires both I/O Module configuration and I/O Module
|
|
administration roles in order to be able to launch a telnet
|
|
or web UI session to an I/O Module, or to restore factory
|
|
defaults on an I/O Module."
|
|
::= { remoteAccessRBSroleEntry 15 }
|
|
|
|
rbsSwitchModuleAdministration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can power on/off and restart the I/O Modules,
|
|
update I/O Module firmware, enable/disable the Fast POST
|
|
and External Ports of an I/O Module. Note that a user
|
|
requires both I/O Module configuration and I/O Module
|
|
administration roles in order to be able to launch a telnet
|
|
or web UI session to an I/O Module, or to restore factory
|
|
defaults on an I/O Module."
|
|
::= { remoteAccessRBSroleEntry 16 }
|
|
|
|
rbsBladeRemotePresenseVideo OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"User can browser Remote Control web panel and remote blade video.
|
|
|
|
NOTE: This mib object is deprecated. This level of granularity is available
|
|
via the LDAP snap-in tool."
|
|
::= { remoteAccessRBSroleEntry 17 }
|
|
|
|
rbsBladeRemotePresenseKVM OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"User has ability to access the Remote Control web panel
|
|
and the functions provided on the panel: remote console
|
|
(KVM) and remote disk.
|
|
|
|
NOTE: This mib object is deprecated. This level of granularity is available
|
|
via the LDAP snap-in tool."
|
|
::= { remoteAccessRBSroleEntry 18 }
|
|
|
|
rbsBladeRemotePresenseRdriveR OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"User can mount remote blade driver, and have read access only.
|
|
|
|
NOTE: This mib object is deprecated. This level of granularity is available
|
|
via the LDAP snap-in tool."
|
|
::= { remoteAccessRBSroleEntry 19 }
|
|
|
|
rbsBladeRemotePresenseRdriveRW OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"User can mount remote blade driver and have read/write access.
|
|
|
|
NOTE: This mib object is deprecated. This level of granularity is available
|
|
via the LDAP snap-in tool."
|
|
::= { remoteAccessRBSroleEntry 20 }
|
|
|
|
rbsChassisRemotePresenseRdoc OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"User has ability to upload/delete own image to RDOC and also
|
|
can start remote control web panel.
|
|
|
|
NOTE: This mib object is deprecated. This level of granularity is available
|
|
via the LDAP snap-in tool."
|
|
::= { remoteAccessRBSroleEntry 21 }
|
|
|
|
rbsRemotePresenceSupervisor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"User has ability to access the Remote Control web panel
|
|
and the functions provided on the panel: remote console
|
|
(KVM) and remote driver read/write, upload/delete himself
|
|
and other's image to RDOC.
|
|
|
|
NOTE: This mib object is deprecated. This level of granularity is available
|
|
via the LDAP snap-in tool."
|
|
::= { remoteAccessRBSroleEntry 22 }
|
|
|
|
remoteAccessRBSscopeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RemoteAccessRBSscopeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of RBS User Scope profiles."
|
|
::= { remoteAccessIds 4 }
|
|
|
|
remoteAccessRBSscopeEntry OBJECT-TYPE
|
|
SYNTAX RemoteAccessRBSscopeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User Scope entries."
|
|
INDEX { scopeIndex }
|
|
::= { remoteAccessRBSscopeTable 1 }
|
|
|
|
RemoteAccessRBSscopeEntry ::= SEQUENCE {
|
|
scopeIndex INTEGER,
|
|
scopeId OCTET STRING,
|
|
rbsChassis INTEGER,
|
|
rbsBlade1 INTEGER,
|
|
rbsBlade2 INTEGER,
|
|
rbsBlade3 INTEGER,
|
|
rbsBlade4 INTEGER,
|
|
rbsBlade5 INTEGER,
|
|
rbsBlade6 INTEGER,
|
|
rbsBlade7 INTEGER,
|
|
rbsBlade8 INTEGER,
|
|
rbsBlade9 INTEGER,
|
|
rbsBlade10 INTEGER,
|
|
rbsBlade11 INTEGER,
|
|
rbsBlade12 INTEGER,
|
|
rbsBlade13 INTEGER,
|
|
rbsBlade14 INTEGER,
|
|
rbsSwitch1 INTEGER,
|
|
rbsSwitch2 INTEGER,
|
|
rbsSwitch3 INTEGER,
|
|
rbsSwitch4 INTEGER,
|
|
rbsSwitch5 INTEGER,
|
|
rbsSwitch6 INTEGER,
|
|
rbsSwitch7 INTEGER,
|
|
rbsSwitch8 INTEGER,
|
|
rbsSwitch9 INTEGER,
|
|
rbsSwitch10 INTEGER
|
|
}
|
|
|
|
|
|
scopeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for RBS User Scope Entry."
|
|
::= { remoteAccessRBSscopeEntry 1 }
|
|
|
|
scopeId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User ID"
|
|
::= { remoteAccessRBSscopeEntry 2 }
|
|
|
|
rbsChassis OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the MM and chassis functions."
|
|
::= { remoteAccessRBSscopeEntry 3 }
|
|
|
|
rbsBlade1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 1."
|
|
::= { remoteAccessRBSscopeEntry 4 }
|
|
|
|
rbsBlade2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 2."
|
|
::= { remoteAccessRBSscopeEntry 5 }
|
|
|
|
|
|
rbsBlade3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 3."
|
|
::= { remoteAccessRBSscopeEntry 6 }
|
|
|
|
rbsBlade4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 4."
|
|
::= { remoteAccessRBSscopeEntry 7 }
|
|
|
|
rbsBlade5 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 5."
|
|
::= { remoteAccessRBSscopeEntry 8 }
|
|
|
|
rbsBlade6 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 6."
|
|
::= { remoteAccessRBSscopeEntry 9 }
|
|
|
|
rbsBlade7 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 7."
|
|
::= { remoteAccessRBSscopeEntry 10 }
|
|
|
|
|
|
rbsBlade8 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 8."
|
|
::= { remoteAccessRBSscopeEntry 11 }
|
|
|
|
rbsBlade9 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 9."
|
|
::= { remoteAccessRBSscopeEntry 12 }
|
|
|
|
rbsBlade10 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 10."
|
|
::= { remoteAccessRBSscopeEntry 13 }
|
|
|
|
rbsBlade11 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 11."
|
|
::= { remoteAccessRBSscopeEntry 14 }
|
|
|
|
rbsBlade12 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 12."
|
|
::= { remoteAccessRBSscopeEntry 15 }
|
|
|
|
|
|
rbsBlade13 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 13."
|
|
::= { remoteAccessRBSscopeEntry 16 }
|
|
|
|
rbsBlade14 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to the blade in slot 14."
|
|
::= { remoteAccessRBSscopeEntry 17 }
|
|
|
|
rbsSwitch1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to I/O module 1."
|
|
::= { remoteAccessRBSscopeEntry 18 }
|
|
|
|
rbsSwitch2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to I/O module 2."
|
|
::= { remoteAccessRBSscopeEntry 19 }
|
|
|
|
rbsSwitch3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to I/O module 3."
|
|
::= { remoteAccessRBSscopeEntry 20 }
|
|
|
|
rbsSwitch4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to I/O module 4."
|
|
::= { remoteAccessRBSscopeEntry 21 }
|
|
|
|
rbsSwitch5 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to I/O module 5."
|
|
::= { remoteAccessRBSscopeEntry 22 }
|
|
|
|
rbsSwitch6 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to I/O module 6."
|
|
::= { remoteAccessRBSscopeEntry 23 }
|
|
|
|
rbsSwitch7 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to I/O module 7."
|
|
::= { remoteAccessRBSscopeEntry 24 }
|
|
|
|
|
|
rbsSwitch8 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to I/O module 8."
|
|
::= { remoteAccessRBSscopeEntry 25 }
|
|
|
|
rbsSwitch9 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to I/O module 9."
|
|
::= { remoteAccessRBSscopeEntry 26 }
|
|
|
|
rbsSwitch10 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User has access to I/O module 10."
|
|
::= { remoteAccessRBSscopeEntry 27 }
|
|
|
|
-- ********************************************************************************
|
|
-- Enable/Disable User Interfaces
|
|
-- ********************************************************************************
|
|
userInterfaces OBJECT IDENTIFIER ::= { remoteAccessConfig 5 }
|
|
cli OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
telnet-only(1),
|
|
ssh-only(2),
|
|
enabled(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/Disable CLI access to the MM (telnet and SSH).
|
|
The value enabled(3) means both telnet and ssh are enabled."
|
|
::= { userInterfaces 1 }
|
|
|
|
snmp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
v1-only(1),
|
|
v3-only(2),
|
|
enabled(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/Disable SNMP v1 and v3 access to the MM."
|
|
::= { userInterfaces 2 }
|
|
|
|
tcm OBJECT-TYPE
|
|
SYNTAX INTEGER (0..20)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/Disable TCM access to the MM.
|
|
A value of 0 means disabled, any value from 1 to 20 means enabled.
|
|
NOTE: AMM will provide a max of 20 connections for both
|
|
Secure TCP Command Mode and TCP Command Mode."
|
|
::= { userInterfaces 3 }
|
|
|
|
web OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/Disable Web access (HTTP/HTTPS) to the MM.
|
|
|
|
NOTE: Disabling web access to the MM will cause all
|
|
currently active web sessions to disconnect,
|
|
and you will no longer be able to access the
|
|
MM management functions using a web browser."
|
|
::= { userInterfaces 4 }
|
|
|
|
stcm OBJECT-TYPE
|
|
SYNTAX INTEGER (0..20)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/Disable STCM access to the MM.
|
|
A value of 0 means disabled, any value from 1 to 20 means enabled.
|
|
NOTE: AMM will provide a max of 20 connections for both
|
|
Secure TCP Command Mode and TCP Command Mode.
|
|
If no valid server certificate is in place,
|
|
Secure TCP Command Mode will not be allowed to set to enable."
|
|
::= { userInterfaces 5 }
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- The Remote Access ID SSH Client Authentication Public Key Group
|
|
-- ---------------------------------------------------------- --
|
|
mmSshClientAuth OBJECT IDENTIFIER ::= { remoteAccessConfig 6 }
|
|
|
|
mmSshClientAuthPubKeyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MmSshClientAuthPubKeyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table that contains client authentication
|
|
public key information."
|
|
::= { mmSshClientAuth 1 }
|
|
|
|
mmSshClientAuthPubKeyEntry OBJECT-TYPE
|
|
SYNTAX MmSshClientAuthPubKeyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A information list about a particular SSH
|
|
public key used for client authentication.
|
|
The primary table index is the same value as
|
|
the associated remoteAccessIdEntryIndex.
|
|
The secondary table index allows selection
|
|
of the Nth public key for that
|
|
remoteAccessIdEntryIndex."
|
|
INDEX { mmSshClientAuthRemoteAccessIdIndex ,
|
|
mmSshClientAuthPubKeyIndex }
|
|
::= { mmSshClientAuthPubKeyTable 1 }
|
|
|
|
MmSshClientAuthPubKeyEntry ::=
|
|
SEQUENCE {
|
|
mmSshClientAuthRemoteAccessIdIndex INTEGER,
|
|
mmSshClientAuthPubKeyIndex INTEGER,
|
|
mmSshClientAuthPubKeyType INTEGER,
|
|
mmSshClientAuthPubKeySize INTEGER,
|
|
mmSshClientAuthPubKeyFingerprint OCTET STRING,
|
|
mmSshClientAuthPubKeyAcceptFrom OCTET STRING,
|
|
mmSshClientAuthPubKeyComment OCTET STRING,
|
|
mmSshClientAuthPubKeyAction INTEGER,
|
|
mmSshClientAuthPubKeyEntryStatus EntryStatus
|
|
}
|
|
|
|
mmSshClientAuthRemoteAccessIdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The primary table index is the same value as
|
|
the associated remoteAccessIdEntryIndex used
|
|
as an index into the remoteAccessIdsTable."
|
|
::= { mmSshClientAuthPubKeyEntry 1 }
|
|
|
|
mmSshClientAuthPubKeyIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The secondary table index used to select
|
|
one of the client authentication public
|
|
keys for a particular remote access Id.
|
|
The index is an integer value from 1 to N
|
|
where N is the number of keys associated
|
|
with a particular remote access Id.
|
|
An addition always causes the value of N to increase
|
|
by one, effectively adding an entry after the
|
|
existing keys for that remote access Id.
|
|
If an entry is deleted from the table by
|
|
setting mmSshClientAuthPubKeyEntryStatus = invalid,
|
|
the key associated with that entry is deleted.
|
|
If the deleted key was not the last key for
|
|
a remote access Id (mmSshClientAuthPubKeyIndex is
|
|
not the 'last' or Nth entry), the subsequent entries
|
|
are renumbered after the deletion. A deletion
|
|
always causes the value of N to decrease by one.
|
|
The underlying SSH server implementation searches
|
|
the keys in order from 1 to N when attempting public
|
|
key authentication.
|
|
|
|
NOTE:A maximum of 4 public keys can be installed
|
|
for one remote access Id."
|
|
::= { mmSshClientAuthPubKeyEntry 2 }
|
|
|
|
mmSshClientAuthPubKeyType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sshDss (1),
|
|
sshRsa (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of the SSH public key represented by
|
|
this entry."
|
|
::= { mmSshClientAuthPubKeyEntry 3 }
|
|
|
|
mmSshClientAuthPubKeySize OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bits512 (1),
|
|
bits768 (2),
|
|
bits1024 (3),
|
|
bits2048 (4),
|
|
bits4096 (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the SSH public key represented by
|
|
this entry."
|
|
::= { mmSshClientAuthPubKeyEntry 4 }
|
|
|
|
mmSshClientAuthPubKeyFingerprint OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RSA fingerprint of the SSH public key represented
|
|
by this entry.
|
|
This value can be used with the SSH client to
|
|
verify, on the initial connection, that the Secure Shell
|
|
server responding to the request is the server running
|
|
on the managed entity. This is the fingerprint of the
|
|
operational host key pair. If the key pair represented
|
|
by this entry is not operational then sixteen null octets
|
|
must be returned."
|
|
::= { mmSshClientAuthPubKeyEntry 5 }
|
|
|
|
mmSshClientAuthPubKeyAcceptFrom OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is a filter that describes the set of SSH client
|
|
IP addresses and host names that can establish
|
|
SSH connections to the AMM authenticated by the public key
|
|
represented by this entry of the table. The filter is a
|
|
comma-separated list of IP addresses and/or hostnames.
|
|
A question mark may be used to match any single character.
|
|
An asterisk may be used to match multiple characters.
|
|
An exclamation point may preceed an IP address or hostname
|
|
to deny acccess from that IP address or hostname.
|
|
|
|
The format of the Accept From specification is:
|
|
from=PATTERN-LIST
|
|
PATTERN-LIST is the filter, which must be enclosed in
|
|
double quotation marks.
|
|
|
|
NOTE:This MIB object can be manipulated after the
|
|
corresponding SSH public key is installed."
|
|
::= { mmSshClientAuthPubKeyEntry 6 }
|
|
|
|
mmSshClientAuthPubKeyComment OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is a descriptive string that the administrator may
|
|
use to help identify the public key represented by this entry.
|
|
It serves no function in the operation of the SSH server.
|
|
|
|
NOTE:This MIB object can be manipulated after the
|
|
corresponding SSH public key is installed."
|
|
::= { mmSshClientAuthPubKeyEntry 7 }
|
|
|
|
mmSshClientAuthPubKeyAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
import(1),
|
|
export(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"import(1) starts the TFTP file transfer of an SSH
|
|
client authentication public key from the TFTP
|
|
server to the AMM. The import operation is only
|
|
accepted if the associated RemoteAccessIdsEntry row
|
|
is configured and the current value of
|
|
mmSshClientAuthPubKeyEntryStatus is underCreation(3)
|
|
or valid(1), if the current value of mmSshClientAuthPubKeyEntryStatus
|
|
is valid(1), it will replace the key with a new key,
|
|
If the import is successful the value of
|
|
mmSshClientAuthPubKeyRowStatus changes to valid(1).
|
|
export(2) starts the TFTP file transfer of an SSH
|
|
client authentication public key from the AMM to the TFTP
|
|
server. The export operation is only accepted if
|
|
the current value of mmSshClientAuthPubKeyEntryStatus
|
|
is valid(1).
|
|
|
|
NOTE: Users should compare the fingerprint value
|
|
mmSshClientAuthPubKeyFingerprint to the
|
|
fingerprint of client authentication key files
|
|
imported or exported using the TFTP file transfer
|
|
protocol to guard against possible file corruption.
|
|
|
|
Value returned for the GET command is meaningless
|
|
for this MIB object."
|
|
::= { mmSshClientAuthPubKeyEntry 8 }
|
|
|
|
mmSshClientAuthPubKeyEntryStatus OBJECT-TYPE
|
|
SYNTAX EntryStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object manages the creation and deletion of this entry.
|
|
The steps recommended to install and to activate a new client
|
|
authorization public key are:
|
|
1. Set values for mmSshClientAuthPubKeyTftpServer,
|
|
mmSshClientAuthPubKeyFileName, mmSshClientAuthPubKeyFileFormat
|
|
2. Create a new entry in this table
|
|
mmSshClientAuthPubKeyEntryStatus = createRequest
|
|
3. Import a new key mmSshClientAuthPubKeyAction = import
|
|
This entry will be valid after mmSshClientAuthPubKeyAction
|
|
is successfully imported.
|
|
4. Set mmSshClientAuthPubKeyAcceptFrom and
|
|
mmSshClientAuthPubKeyComment as required.
|
|
|
|
valid(1) - Indicates that the public key pair represented
|
|
by this entry is available for use by the Secure
|
|
Shell Server for client authentication.
|
|
|
|
createRequest(2) - A new entry will be created in this table
|
|
for the specified host key pair and the new
|
|
entry will transition to the underCreation(3)
|
|
state. The operation is only accepted if the
|
|
associated RemoteAccessIdsEntry row defining
|
|
a local user account is configured.
|
|
|
|
underCreation(3) - Indicates that this entry exists in the
|
|
agent but is unavailable for use. After completing the
|
|
create operation, the agent will set this object to
|
|
underCreation(3).
|
|
|
|
invalid(4) - Deletes this entry and any client authentication
|
|
public key that may be associated with it."
|
|
::= { mmSshClientAuthPubKeyEntry 9 }
|
|
|
|
mmSshClientAuthPubKeyUnused OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of available storage locations that may be
|
|
used to install additional Client Authentication
|
|
Public Keys. This number decreases by one when a new
|
|
key is added to the configuration."
|
|
::= { mmSshClientAuth 2 }
|
|
|
|
mmSshClientAuthPubKeyTftpServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or host name of the TFTP server where an SSH client
|
|
authentication public key is to be installed from or exported
|
|
to. The address must be entered in a dotted decimal
|
|
IP string (e.g. 9.37.44.2)."
|
|
::= { mmSshClientAuth 3 }
|
|
|
|
mmSshClientAuthPubKeyFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"File name on the TFTP server of an SSH client
|
|
authentication public key."
|
|
::= { mmSshClientAuth 4 }
|
|
|
|
mmSshClientAuthPubKeyFileFormat OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
openSSH (1),
|
|
rfc4716 (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"File format of SSH client authentication public key files
|
|
imported from or exported to the TFTP file server."
|
|
::= { mmSshClientAuth 5 }
|
|
|
|
-- ********************************************************************************
|
|
-- Group Profiles for LDAP Users
|
|
-- ********************************************************************************
|
|
groupProfiles OBJECT IDENTIFIER ::= { remoteAccessConfig 7 }
|
|
groupIdsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF GroupIdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Group profiles.
|
|
|
|
This table lets you to configure all group profiles.
|
|
You can define up to 16 unique profiles."
|
|
::= { groupProfiles 1 }
|
|
|
|
groupIdsEntry OBJECT-TYPE
|
|
SYNTAX GroupIdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group ID entries."
|
|
INDEX { groupIndex }
|
|
::= { groupIdsTable 1 }
|
|
|
|
|
|
GroupIdsEntry ::= SEQUENCE {
|
|
groupIndex INTEGER,
|
|
groupId OCTET STRING,
|
|
groupRole OCTET STRING,
|
|
groupEntryStatus EntryStatus
|
|
}
|
|
|
|
|
|
groupIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for Group IDs entry."
|
|
::= { groupIdsEntry 1 }
|
|
|
|
groupId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group ID. It is a null terminated string that contains the group-id.
|
|
It must not be a duplicate of any previously configured ones."
|
|
::= { groupIdsEntry 2 }
|
|
|
|
|
|
groupRole OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group Role. It indicates if the group has supervisor, operator,
|
|
or custom access."
|
|
::= { groupIdsEntry 3 }
|
|
|
|
groupEntryStatus OBJECT-TYPE
|
|
SYNTAX EntryStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object manages the creation and deletion of this entry.
|
|
The steps recommended to add a new group are:
|
|
1. Create a new entry in this table
|
|
groupEntryStatus = createRequest
|
|
2. Set groupId as required.
|
|
Then the entry will be valid.
|
|
|
|
valid(1) - Indicates that the group represented
|
|
by this entry is available for use.
|
|
|
|
createRequest(2) - A new entry will be created in this table
|
|
for the specified group and the new entry
|
|
will transition to the underCreation(3).
|
|
|
|
underCreation(3) - Indicates that this entry exists in the
|
|
agent but is unavailable for use. After completing the
|
|
create operation, the agent will set this object to
|
|
underCreation(3).
|
|
|
|
invalid(4) - Deletes this entry."
|
|
::= { groupIdsEntry 9 }
|
|
|
|
groupRBSroleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF GroupRBSroleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Group Role profiles."
|
|
::= { groupProfiles 2 }
|
|
|
|
groupRBSroleEntry OBJECT-TYPE
|
|
SYNTAX GroupRBSroleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group Role entries."
|
|
INDEX { groupRBSroleIndex }
|
|
::= { groupRBSroleTable 1 }
|
|
|
|
GroupRBSroleEntry ::= SEQUENCE {
|
|
groupRBSroleIndex INTEGER,
|
|
groupRBSroleId OCTET STRING,
|
|
groupRBSSupervisor INTEGER,
|
|
groupRBSOperator INTEGER,
|
|
groupRBSChassisOperator INTEGER,
|
|
groupRBSChassisAccountManagement INTEGER,
|
|
groupRBSChassisLogManagement INTEGER,
|
|
groupRBSChassisConfiguration INTEGER,
|
|
groupRBSChassisAdministration INTEGER,
|
|
groupRBSBladeOperator INTEGER,
|
|
groupRBSBladeRemotePresence INTEGER,
|
|
groupRBSBladeConfiguration INTEGER,
|
|
groupRBSBladeAdministration INTEGER,
|
|
groupRBSSwitchModuleOperator INTEGER,
|
|
groupRBSSwitchModuleConfiguration INTEGER,
|
|
groupRBSSwitchModuleAdministration INTEGER
|
|
}
|
|
|
|
|
|
groupRBSroleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for Group Role entry."
|
|
::= { groupRBSroleEntry 1 }
|
|
|
|
groupRBSroleId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group ID"
|
|
::= { groupRBSroleEntry 2 }
|
|
|
|
groupRBSSupervisor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has no restrictions."
|
|
::= { groupRBSroleEntry 3 }
|
|
|
|
groupRBSOperator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has read-only access, and cannot perform
|
|
any save, modify, clear, or state affecting operations
|
|
(e.g. restart MM, restore defaults, upgrade the firmware, etc.)."
|
|
::= { groupRBSroleEntry 4 }
|
|
|
|
groupRBSChassisOperator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has ability to browse status and properties of
|
|
chassis components (MM, blowers (chassis cooling devices), midplane, power modules,
|
|
media tray. Ability to backup MM configuration to a file.
|
|
Saving MM configuration to chassis requires supervisor access."
|
|
::= { groupRBSroleEntry 5 }
|
|
|
|
|
|
groupRBSChassisAccountManagement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group can add/modify/delete user login profiles. Ability
|
|
to backup MM configuration to a file. Changing global login
|
|
settings require chassis configuration authority."
|
|
::= { groupRBSroleEntry 6 }
|
|
|
|
groupRBSChassisLogManagement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has ability to clear the MM event log, change log
|
|
policy settings, and backup MM configuration to a file."
|
|
::= { groupRBSroleEntry 7 }
|
|
|
|
groupRBSChassisConfiguration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group can modify and save any chassis configuration
|
|
parameter (except user profiles and event log settings).
|
|
Ability to restore MM factory defaults if the group also has
|
|
chassis administration permissions. Ability to change the
|
|
global login settings, SOL configuration, and backup MM
|
|
configuration to a file."
|
|
::= { groupRBSroleEntry 8 }
|
|
|
|
groupRBSChassisAdministration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has ability to do MM firmware updates, modify chassis
|
|
LEDs, restore MM factory defaults if the group also has
|
|
chassis configuration permissions. Ability to restart MM
|
|
and backup MM configuration to a file."
|
|
::= { groupRBSroleEntry 9 }
|
|
|
|
groupRBSBladeOperator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has ability to browse status and properties of
|
|
blades."
|
|
::= { groupRBSroleEntry 10 }
|
|
|
|
groupRBSBladeRemotePresence OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has ability to access the Remote Control web panel
|
|
and the functions provided on the panel: remote console
|
|
(KVM) and remote disk. The ability to issue the CLI
|
|
console command to start an SOL session to a blade will
|
|
also require this authority."
|
|
::= { groupRBSroleEntry 11 }
|
|
|
|
groupRBSBladeConfiguration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group can modify and save any blade configuration parameter."
|
|
::= { groupRBSroleEntry 12 }
|
|
|
|
groupRBSBladeAdministration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group can power on/off and restart blades, activate
|
|
standby blades, do firmware updates, and modify blade LEDs."
|
|
::= { groupRBSroleEntry 13 }
|
|
|
|
groupRBSSwitchModuleOperator OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has ability to browse status and properties of
|
|
I/O Modules, and to ping I/O Modules."
|
|
::= { groupRBSroleEntry 14 }
|
|
|
|
groupRBSSwitchModuleConfiguration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group can modify the I/O Module IP address, configure
|
|
I/O Module Advanced Management parameters, and restore
|
|
factory defaults on an I/O Module. Note that a group
|
|
requires both I/O Module configuration and I/O Module
|
|
administration roles in order to be able to launch a telnet
|
|
or web UI session to an I/O Module, or to restore factory
|
|
defaults on an I/O Module."
|
|
::= { groupRBSroleEntry 15 }
|
|
|
|
groupRBSSwitchModuleAdministration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group can power on/off and restart the I/O Modules,
|
|
update I/O Module firmware, enable/disable the Fast POST
|
|
and External Ports of an I/O Module. Note that a group
|
|
requires both I/O Module configuration and I/O Module
|
|
administration roles in order to be able to launch a telnet
|
|
or web UI session to an I/O Module, or to restore factory
|
|
defaults on an I/O Module."
|
|
::= { groupRBSroleEntry 16 }
|
|
|
|
|
|
groupRBSscopeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF GroupRBSscopeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Group Scope profiles."
|
|
::= { groupProfiles 3 }
|
|
|
|
groupRBSscopeEntry OBJECT-TYPE
|
|
SYNTAX GroupRBSscopeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group Scope entries."
|
|
INDEX { groupRBSscopeIndex }
|
|
::= { groupRBSscopeTable 1 }
|
|
|
|
GroupRBSscopeEntry ::= SEQUENCE {
|
|
groupRBSscopeIndex INTEGER,
|
|
groupRBSscopeId OCTET STRING,
|
|
groupRBSChassis INTEGER,
|
|
groupRBSBlade1 INTEGER,
|
|
groupRBSBlade2 INTEGER,
|
|
groupRBSBlade3 INTEGER,
|
|
groupRBSBlade4 INTEGER,
|
|
groupRBSBlade5 INTEGER,
|
|
groupRBSBlade6 INTEGER,
|
|
groupRBSBlade7 INTEGER,
|
|
groupRBSBlade8 INTEGER,
|
|
groupRBSBlade9 INTEGER,
|
|
groupRBSBlade10 INTEGER,
|
|
groupRBSBlade11 INTEGER,
|
|
groupRBSBlade12 INTEGER,
|
|
groupRBSBlade13 INTEGER,
|
|
groupRBSBlade14 INTEGER,
|
|
groupRBSSwitch1 INTEGER,
|
|
groupRBSSwitch2 INTEGER,
|
|
groupRBSSwitch3 INTEGER,
|
|
groupRBSSwitch4 INTEGER,
|
|
groupRBSSwitch5 INTEGER,
|
|
groupRBSSwitch6 INTEGER,
|
|
groupRBSSwitch7 INTEGER,
|
|
groupRBSSwitch8 INTEGER,
|
|
groupRBSSwitch9 INTEGER,
|
|
groupRBSSwitch10 INTEGER
|
|
}
|
|
|
|
|
|
groupRBSscopeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for Group Scope Entry."
|
|
::= { groupRBSscopeEntry 1 }
|
|
|
|
groupRBSscopeId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group ID"
|
|
::= { groupRBSscopeEntry 2 }
|
|
|
|
groupRBSChassis OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to the MM and chassis functions."
|
|
::= { groupRBSscopeEntry 3 }
|
|
|
|
groupRBSBlade1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to the blade in slot 1."
|
|
::= { groupRBSscopeEntry 4 }
|
|
|
|
groupRBSBlade2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to the blade in slot 2."
|
|
::= { groupRBSscopeEntry 5 }
|
|
|
|
|
|
groupRBSBlade3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to the blade in slot 3."
|
|
::= { groupRBSscopeEntry 6 }
|
|
|
|
groupRBSBlade4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to the blade in slot 4."
|
|
::= { groupRBSscopeEntry 7 }
|
|
|
|
groupRBSBlade5 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to the blade in slot 5."
|
|
::= { groupRBSscopeEntry 8 }
|
|
|
|
groupRBSBlade6 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to the blade in slot 6."
|
|
::= { groupRBSscopeEntry 9 }
|
|
|
|
groupRBSBlade7 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to the blade in slot 7."
|
|
::= { groupRBSscopeEntry 10 }
|
|
|
|
|
|
groupRBSBlade8 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to the blade in slot 8."
|
|
::= { groupRBSscopeEntry 11 }
|
|
|
|
groupRBSBlade9 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to the blade in slot 9."
|
|
::= { groupRBSscopeEntry 12 }
|
|
|
|
groupRBSBlade10 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to the blade in slot 10."
|
|
::= { groupRBSscopeEntry 13 }
|
|
|
|
groupRBSBlade11 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to the blade in slot 11."
|
|
::= { groupRBSscopeEntry 14 }
|
|
|
|
groupRBSBlade12 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to the blade in slot 12."
|
|
::= { groupRBSscopeEntry 15 }
|
|
|
|
|
|
groupRBSBlade13 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to the blade in slot 13."
|
|
::= { groupRBSscopeEntry 16 }
|
|
|
|
groupRBSBlade14 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to the blade in slot 14."
|
|
::= { groupRBSscopeEntry 17 }
|
|
|
|
groupRBSSwitch1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to I/O module 1."
|
|
::= { groupRBSscopeEntry 18 }
|
|
|
|
groupRBSSwitch2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to I/O module 2."
|
|
::= { groupRBSscopeEntry 19 }
|
|
|
|
groupRBSSwitch3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to I/O module 3."
|
|
::= { groupRBSscopeEntry 20 }
|
|
|
|
groupRBSSwitch4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to I/O module 4."
|
|
::= { groupRBSscopeEntry 21 }
|
|
|
|
groupRBSSwitch5 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to I/O module 5."
|
|
::= { groupRBSscopeEntry 22 }
|
|
|
|
groupRBSSwitch6 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to I/O module 6."
|
|
::= { groupRBSscopeEntry 23 }
|
|
|
|
groupRBSSwitch7 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to I/O module 7."
|
|
::= { groupRBSscopeEntry 24 }
|
|
|
|
|
|
groupRBSSwitch8 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to I/O module 8."
|
|
::= { groupRBSscopeEntry 25 }
|
|
|
|
groupRBSSwitch9 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to I/O module 9."
|
|
::= { groupRBSscopeEntry 26 }
|
|
|
|
groupRBSSwitch10 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Group has access to I/O module 10."
|
|
::= { groupRBSscopeEntry 27 }
|
|
|
|
-- ********************************************************************************
|
|
-- Remote Alert types
|
|
-- ********************************************************************************
|
|
remoteAlerts OBJECT IDENTIFIER ::= { configureSP 2 }
|
|
|
|
-- ********************************************************************************
|
|
-- Remote Alert Critical Error types
|
|
-- ********************************************************************************
|
|
remoteAlertsCrit OBJECT IDENTIFIER ::= { remoteAlerts 1 }
|
|
|
|
critTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Generate an alert if any of the monitored temperature sensors
|
|
in the system exceed their critical threshold.
|
|
|
|
NOTE: If a critical Temperature condition is detected,
|
|
the server will automatically be shut down and powered off
|
|
whether this object is enabled or not.
|
|
|
|
NOTE: The legacy(0) mode alerts should no longer be used
|
|
and have been deprecated for several releases. They are
|
|
now also changed to be read-only and any future modifications
|
|
to the alert category settings must be done only with the
|
|
enahanced(1) mode alerts."
|
|
::= { remoteAlertsCrit 1 }
|
|
|
|
critVolt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Generate a alert if any of the monitored power supply sensors
|
|
in the system fall outside their specified critical
|
|
operational range.
|
|
|
|
NOTE: If a critical voltage condition is detected,
|
|
the server will automatically be shut down and powered off
|
|
whether this object is enabled or not.
|
|
|
|
NOTE: The legacy(0) mode alerts should no longer be used
|
|
and have been deprecated for several releases. They are
|
|
now also changed to be read-only and any future modifications
|
|
to the alert category settings must be done only with the
|
|
enahanced(1) mode alerts."
|
|
::= { remoteAlertsCrit 2 }
|
|
|
|
|
|
critMultiBlower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Generate an alert if multiple blowers used for cooling the system fail.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices.
|
|
|
|
NOTE: The legacy(0) mode alerts should no longer be used
|
|
and have been deprecated for several releases. They are
|
|
now also changed to be read-only and any future modifications
|
|
to the alert category settings must be done only with the
|
|
enahanced(1) mode alerts."
|
|
::= { remoteAlertsCrit 4 }
|
|
|
|
critPower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if any of the system power supplies fail.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsCrit 5 }
|
|
|
|
critHardDrive OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Generate an alert if any of hard disk drives fail.
|
|
|
|
NOTE: The legacy(0) mode alerts should no longer be used
|
|
and have been deprecated for several releases. They are
|
|
now also changed to be read-only and any future modifications
|
|
to the alert category settings must be done only with the
|
|
enahanced(1) mode alerts."
|
|
::= { remoteAlertsCrit 6 }
|
|
|
|
critVRM OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Generate an alert if any of VRM (voltage regulator modules) fail.
|
|
|
|
NOTE: The legacy(0) mode alerts should no longer be used
|
|
and have been deprecated for several releases. They are
|
|
now also changed to be read-only and any future modifications
|
|
to the alert category settings must be done only with the
|
|
enahanced(1) mode alerts."
|
|
::= { remoteAlertsCrit 7 }
|
|
|
|
critMultipleSwitchModule OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Generate an alert if all switch modules fail or are removed.
|
|
|
|
NOTE: The legacy(0) mode alerts should no longer be used
|
|
and have been deprecated for several releases. They are
|
|
now also changed to be read-only and any future modifications
|
|
to the alert category settings must be done only with the
|
|
enahanced(1) mode alerts."
|
|
::= { remoteAlertsCrit 8 }
|
|
|
|
critInvalidConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Generate an alert if the hardware configuration is incompatible.
|
|
|
|
NOTE: The legacy(0) mode alerts should no longer be used
|
|
and have been deprecated for several releases. They are
|
|
now also changed to be read-only and any future modifications
|
|
to the alert category settings must be done only with the
|
|
enahanced(1) mode alerts."
|
|
::= { remoteAlertsCrit 9 }
|
|
|
|
critBlade OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert for any critical error condition on a blade.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsCrit 10 }
|
|
|
|
critIO OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert for any critical error condition on I/O module.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsCrit 11 }
|
|
|
|
critStorage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert for any critical error condition on a Storage module.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { remoteAlertsCrit 12 }
|
|
|
|
critChassis OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert for any critical error condition on chassis.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsCrit 13 }
|
|
|
|
critFan OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert for any critical error condition on cooling devices.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsCrit 14 }
|
|
|
|
-- ********************************************************************************
|
|
-- Remote Alert Warning(non-critical) Error types
|
|
-- ********************************************************************************
|
|
remoteAlertsNonCrit OBJECT IDENTIFIER ::= { remoteAlerts 2 }
|
|
|
|
warnSingleBlower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Generate an alert if one blower used for cooling the system fails.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices.
|
|
|
|
NOTE: The legacy(0) mode alerts should no longer be used
|
|
and have been deprecated for several releases. They are
|
|
now also changed to be read-only and any future modifications
|
|
to the alert category settings must be done only with the
|
|
enahanced(1) mode alerts."
|
|
::= { remoteAlertsNonCrit 2 }
|
|
|
|
warnTemp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Generate an alert if any of the monitored temperature sensors
|
|
in the system exceed their warning threshold.
|
|
|
|
NOTE: The legacy(0) mode alerts should no longer be used
|
|
and have been deprecated for several releases. They are
|
|
now also changed to be read-only and any future modifications
|
|
to the alert category settings must be done only with the
|
|
enahanced(1) mode alerts."
|
|
::= { remoteAlertsNonCrit 3 }
|
|
|
|
warnVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Generate an alert if any of the monitored power supply sensors
|
|
in the system fall outside their specified warning operational range.
|
|
|
|
NOTE: The legacy(0) mode alerts should no longer be used
|
|
and have been deprecated for several releases. They are
|
|
now also changed to be read-only and any future modifications
|
|
to the alert category settings must be done only with the
|
|
enahanced(1) mode alerts."
|
|
::= { remoteAlertsNonCrit 4 }
|
|
|
|
warnRedundantModule OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Generate an alert if any of the switch modules or management
|
|
modules is failing or removed.
|
|
|
|
NOTE: The legacy(0) mode alerts should no longer be used
|
|
and have been deprecated for several releases. They are
|
|
now also changed to be read-only and any future modifications
|
|
to the alert category settings must be done only with the
|
|
enahanced(1) mode alerts."
|
|
::= { remoteAlertsNonCrit 6 }
|
|
|
|
warnMediaTrayKVMSwitch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Generate an alert if the system detects a Media Tray or KVM
|
|
switching failure.
|
|
|
|
NOTE: The legacy(0) mode alerts should no longer be used
|
|
and have been deprecated for several releases. They are
|
|
now also changed to be read-only and any future modifications
|
|
to the alert category settings must be done only with the
|
|
enahanced(1) mode alerts."
|
|
::= { remoteAlertsNonCrit 7 }
|
|
|
|
warnLogFull OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if the system log reaches 100% full.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsNonCrit 10 }
|
|
|
|
warnBlade OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert for any warning condition on a blade.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsNonCrit 15 }
|
|
|
|
warnIO OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert for any warning condition on I/O module.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsNonCrit 16 }
|
|
|
|
warnStorage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert for any warning condition on a Storage module.
|
|
|
|
NOTE: This MIB object is for BCS only.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsNonCrit 17 }
|
|
|
|
warnPower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert for any warning condition on power module.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsNonCrit 18 }
|
|
|
|
warnChassis OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert for any warning condition on chassis.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsNonCrit 19 }
|
|
|
|
warnFan OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert for any warning condition on cooling devices.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsNonCrit 20 }
|
|
|
|
-- ********************************************************************************
|
|
-- Remote Alert System Error types
|
|
-- ********************************************************************************
|
|
remoteAlertsSystem OBJECT IDENTIFIER ::= { remoteAlerts 3 }
|
|
|
|
|
|
systemPowerOff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Generate an alert if the system is powered off.
|
|
|
|
NOTE: The legacy(0) mode alerts should no longer be used
|
|
and have been deprecated for several releases. They are
|
|
now also changed to be read-only and any future modifications
|
|
to the alert category settings must be done only with the
|
|
enahanced(1) mode alerts."
|
|
::= { remoteAlertsSystem 4 }
|
|
|
|
systemPowerOn OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Generate a alert if the system is powered on.
|
|
|
|
NOTE: The legacy(0) mode alerts should no longer be used
|
|
and have been deprecated for several releases. They are
|
|
now also changed to be read-only and any future modifications
|
|
to the alert category settings must be done only with the
|
|
enahanced(1) mode alerts."
|
|
::= { remoteAlertsSystem 5 }
|
|
|
|
systemPFA OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Generate a alert if the system hardware detects a Predictive
|
|
Failure Analysis(PFA) on PFA enabled hardware.
|
|
|
|
NOTE: The legacy(0) mode alerts should no longer be used
|
|
and have been deprecated for several releases. They are
|
|
now also changed to be read-only and any future modifications
|
|
to the alert category settings must be done only with the
|
|
enahanced(1) mode alerts."
|
|
::= { remoteAlertsSystem 8 }
|
|
|
|
systemInventory OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if the a processor blade or media tray is
|
|
added or removed.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsSystem 10 }
|
|
|
|
systemLog75PctFull OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if the system log reaches 75% full.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsSystem 11 }
|
|
|
|
networkChangeNotification OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if the SP has restarted and the internal
|
|
network has initialized successfully, or if an IP address
|
|
change via a source other than the management module.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsSystem 12 }
|
|
|
|
systemBladeThrottling OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Generate an alert if any of the server blades are throttling.
|
|
|
|
NOTE: The legacy(0) mode alerts should no longer be used
|
|
and have been deprecated for several releases. They are
|
|
now also changed to be read-only and any future modifications
|
|
to the alert category settings must be done only with the
|
|
enahanced(1) mode alerts."
|
|
::= { remoteAlertsSystem 13 }
|
|
|
|
systemPowerManagement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Generate an alert if the system detects a power oversubscription
|
|
condition or power supply mismatch in a power domain.
|
|
|
|
NOTE: The legacy(0) mode alerts should no longer be used
|
|
and have been deprecated for several releases. They are
|
|
now also changed to be read-only and any future modifications
|
|
to the alert category settings must be done only with the
|
|
enahanced(1) mode alerts."
|
|
::= { remoteAlertsSystem 14 }
|
|
|
|
systemRemoteLogin OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert if the system detects a new user logged in from
|
|
a remote site.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsSystem 15 }
|
|
|
|
systemBlade OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert for any informational condition on a blade.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsSystem 16 }
|
|
|
|
systemIO OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert for any informational condition on I/O module.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsSystem 17 }
|
|
|
|
systemStorage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert for any informational condition on a Storage module.
|
|
|
|
NOTE: This MIB object is for BCS only.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsSystem 18 }
|
|
|
|
systemPower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert for any informational condition on power module.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsSystem 19 }
|
|
|
|
systemChassis OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert for any informational condition on chassis.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsSystem 20}
|
|
|
|
systemFan OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert for any informational condition on cooling device.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsSystem 21}
|
|
|
|
systemPWRDO OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate an alert for any informational condition on power on and power off.
|
|
|
|
NOTE: This object is valid when the alertMode object is
|
|
set enhanced(1) and should be used for all alert
|
|
category configuration."
|
|
::= { remoteAlertsSystem 22}
|
|
|
|
-- Flag to select whether the alert categories function in the legacy mode or
|
|
-- the enhanced mode.
|
|
|
|
alertMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
legacy(0),
|
|
enhanced(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selects which alert categories will be displayed on the
|
|
web interface, which alert category objects are accessible
|
|
through SNMP, and which SNMP trap type an alert is associated with.
|
|
|
|
The enhanced option provides a component based category
|
|
category scheme and is the only one that is now supported.
|
|
|
|
NOTE: The legacy(0) mode alerts should no longer be used
|
|
and have been deprecated for several releases. They are
|
|
now also changed to be read-only and any future modifications
|
|
to the alert category settings must be done only with the
|
|
enahanced(1) mode alerts. Therefore, this setting should
|
|
have a value of enhanced(1)."
|
|
|
|
::= { remoteAlerts 4 }
|
|
|
|
-- ********************************************************************************
|
|
-- Users
|
|
-- ********************************************************************************
|
|
--
|
|
users OBJECT IDENTIFIER ::= { monitors 17 }
|
|
|
|
-- ********************************************************************************
|
|
-- MM Users
|
|
-- ********************************************************************************
|
|
--
|
|
mmUsers OBJECT IDENTIFIER ::= { users 1 }
|
|
|
|
currentlyLoggedInTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CurrentlyLoggedInEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of MM users currently logged in.
|
|
|
|
NOTE: This MIB object is for AMM only."
|
|
::= { mmUsers 1 }
|
|
|
|
currentlyLoggedInEntry OBJECT-TYPE
|
|
SYNTAX CurrentlyLoggedInEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM users currently logged in entries.
|
|
|
|
NOTE: This MIB object is for AMM only."
|
|
INDEX { currentlyLoggedInEntryIndex }
|
|
::= { currentlyLoggedInTable 1 }
|
|
|
|
CurrentlyLoggedInEntry ::= SEQUENCE {
|
|
currentlyLoggedInEntryIndex INTEGER,
|
|
currentlyLoggedInEntryUserId OCTET STRING,
|
|
currentlyLoggedInEntryAccMethod OCTET STRING
|
|
}
|
|
|
|
currentlyLoggedInEntryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for MM users currently logged in."
|
|
|
|
::= { currentlyLoggedInEntry 1 }
|
|
|
|
currentlyLoggedInEntryUserId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name for MM users currently logged in.
|
|
NOTE: 'Default SNMPv1 user' indicates an internal user used by SNMPv1 agent."
|
|
|
|
::= { currentlyLoggedInEntry 2 }
|
|
|
|
currentlyLoggedInEntryAccMethod OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..32))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Access method for MM users currently logged in."
|
|
|
|
::= { currentlyLoggedInEntry 3 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Front Bezel
|
|
-- ********************************************************************************
|
|
frontbezel OBJECT IDENTIFIER ::= { monitors 12 }
|
|
|
|
frontbezelExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the front bezel is installed or not.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { frontbezel 1}
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Environmental Monitor Thresholds
|
|
-- ********************************************************************************
|
|
monitorThresholds OBJECT IDENTIFIER ::= { monitors 20 }
|
|
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Voltage Thresholds
|
|
-- ********************************************************************************
|
|
voltageThresholds OBJECT IDENTIFIER ::= { monitorThresholds 2 }
|
|
|
|
voltageThresholdsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VoltageThresholdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of voltage threshold entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter only."
|
|
::= { voltageThresholds 1 }
|
|
|
|
voltageThresholdsEntry OBJECT-TYPE
|
|
SYNTAX VoltageThresholdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage threshold entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter only."
|
|
INDEX { voltageThresholdEntryIndex }
|
|
::= { voltageThresholdsTable 1 }
|
|
|
|
VoltageThresholdsEntry ::= SEQUENCE {
|
|
voltageThresholdEntryIndex INTEGER,
|
|
voltageThresholdEntryName OCTET STRING,
|
|
voltageThresholdEntryCurrentValue OCTET STRING,
|
|
voltageThresholdEntryWarningHighValue OCTET STRING,
|
|
voltageThresholdEntryWarningResetHighValue OCTET STRING,
|
|
voltageThresholdEntryWarningLowValue OCTET STRING,
|
|
voltageThresholdEntryWarningResetLowValue OCTET STRING
|
|
}
|
|
|
|
|
|
voltageThresholdEntryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for voltage threshold entry."
|
|
|
|
::= { voltageThresholdsEntry 1 }
|
|
|
|
voltageThresholdEntryName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage threshold entry null terminated string that
|
|
contains the power supply's name, for example '+5V'."
|
|
|
|
::= { voltageThresholdsEntry 2 }
|
|
|
|
voltageThresholdEntryCurrentValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
|
|
::= { voltageThresholdsEntry 3 }
|
|
|
|
voltageThresholdEntryWarningHighValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage threshold reading expressed in Volts(V).
|
|
If the voltage rises above this value, a warning
|
|
alert/event, if enabled, will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
|
|
::= { voltageThresholdsEntry 6 }
|
|
|
|
voltageThresholdEntryWarningResetHighValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage threshold reading expressed in Volts(V).
|
|
If the voltage rises above this value and
|
|
if a warning alert/event had previously been
|
|
created, then the alert/event will be reset.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
|
|
::= { voltageThresholdsEntry 7 }
|
|
|
|
voltageThresholdEntryWarningLowValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage threshold reading expressed in Volts(V).
|
|
If the voltage drops below this value, a warning
|
|
alert/event, if enabled, will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
|
|
::= { voltageThresholdsEntry 10 }
|
|
|
|
voltageThresholdEntryWarningResetLowValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage threshold reading expressed in Volts(V).
|
|
If the voltage drops below this value and
|
|
if a warning alert/event had previously been
|
|
created, then the alert/event will be reset.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system."
|
|
|
|
::= { voltageThresholdsEntry 11 }
|
|
|
|
-- ********************************************************************************
|
|
-- Vital Product Data(VPD) information
|
|
-- ********************************************************************************
|
|
vpdInformation OBJECT IDENTIFIER ::= { monitors 21 }
|
|
|
|
-- ********************************************************************************
|
|
-- System Firmware Level VPD
|
|
-- ********************************************************************************
|
|
|
|
-- ********************************************************************************
|
|
-- Machine Level VPD
|
|
-- ********************************************************************************
|
|
chassisVpd OBJECT IDENTIFIER ::= { vpdInformation 1 }
|
|
|
|
|
|
bladeCenterVpd OBJECT IDENTIFIER ::= { chassisVpd 1 }
|
|
|
|
bladeCenterVpdMachineType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine type VPD information (from System BIOS). This field must be four
|
|
alpha numeric characters."
|
|
::= { bladeCenterVpd 1 }
|
|
|
|
bladeCenterVpdMachineModel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine model VPD information (from System BIOS). This field must be three
|
|
alpha numeric characters."
|
|
::= { bladeCenterVpd 2 }
|
|
|
|
bladeCenterSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine serial number VPD information (from System BIOS). This field must be
|
|
seven alpha numeric characters."
|
|
::= { bladeCenterVpd 3 }
|
|
|
|
bladeCenterUUID OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine UUID (Universal Unique ID information) (from System BIOS). This field
|
|
must be 32 alpha numeric characters."
|
|
::= { bladeCenterVpd 4 }
|
|
|
|
bladeCenterManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine chassis manufacturing ID."
|
|
::= { bladeCenterVpd 5 }
|
|
|
|
bladeCenterHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine chassis hardware revision.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { bladeCenterVpd 6 }
|
|
|
|
|
|
bladeCenterFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine chassis FRU number."
|
|
::= { bladeCenterVpd 7 }
|
|
|
|
bladeCenterManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine chassis manufacture date."
|
|
::= { bladeCenterVpd 8 }
|
|
|
|
bladeCenterPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine chassis part number."
|
|
::= { bladeCenterVpd 9 }
|
|
|
|
bladeCenterFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine chassis FRU serial number."
|
|
::= { bladeCenterVpd 10 }
|
|
|
|
bladeCenterManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine chassis manufacturer ID Number."
|
|
::= { bladeCenterVpd 11 }
|
|
|
|
bladeCenterProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine chassis product ID."
|
|
::= { bladeCenterVpd 12 }
|
|
|
|
bladeCenterSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine chassis subsystem manufacturer."
|
|
::= { bladeCenterVpd 13 }
|
|
|
|
bladeCenterClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine chassis Common Language Equipment Identification (CLEI)."
|
|
::= { bladeCenterVpd 14 }
|
|
|
|
bladeCenterDirectSerialAttach OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Presence of the Direct Serial Attach Module.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { bladeCenterVpd 15 }
|
|
|
|
bladeCenterHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Machine chassis hardware revision in string format.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { bladeCenterVpd 16 }
|
|
|
|
-- ********************************************************************************
|
|
-- Management Module Hardware VPD
|
|
-- ********************************************************************************
|
|
mmHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 2 }
|
|
|
|
mmHardwareVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MmHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the management module hardware components.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mmHardwareVpd 1 }
|
|
|
|
mmHardwareVpdEntry OBJECT-TYPE
|
|
SYNTAX MmHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
INDEX { mmHardwareVpdIndex }
|
|
::= { mmHardwareVpdTable 1 }
|
|
|
|
MmHardwareVpdEntry ::= SEQUENCE {
|
|
mmHardwareVpdIndex INTEGER,
|
|
mmHardwareVpdBayNumber OCTET STRING,
|
|
mmHardwareVpdManufacturingId OCTET STRING,
|
|
mmHardwareVpdFruNumber OCTET STRING,
|
|
mmHardwareVpdHardwareRevision INTEGER,
|
|
mmHardwareVpdUuid OCTET STRING,
|
|
mmHardwareVpdManufDate OCTET STRING,
|
|
mmHardwareVpdPartNumber OCTET STRING,
|
|
mmHardwareVpdFruSerial OCTET STRING,
|
|
mmHardwareVpdManufacturingIDNumber OCTET STRING,
|
|
mmHardwareVpdProductId OCTET STRING,
|
|
mmHardwareVpdSubManufacturerId OCTET STRING,
|
|
mmHardwareVpdClei OCTET STRING,
|
|
mmHardwareVpdHardwareRevisionString OCTET STRING
|
|
}
|
|
|
|
mmHardwareVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD index.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mmHardwareVpdEntry 1 }
|
|
|
|
mmHardwareVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD Bay number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mmHardwareVpdEntry 2 }
|
|
|
|
mmHardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mmHardwareVpdEntry 3 }
|
|
mmHardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mmHardwareVpdEntry 4 }
|
|
|
|
|
|
mmHardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { mmHardwareVpdEntry 5 }
|
|
|
|
mmHardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD UUID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mmHardwareVpdEntry 6 }
|
|
|
|
mmHardwareVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD manufacture date.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mmHardwareVpdEntry 7 }
|
|
|
|
mmHardwareVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD Part number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mmHardwareVpdEntry 8 }
|
|
|
|
mmHardwareVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD FRU serial number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mmHardwareVpdEntry 9 }
|
|
|
|
mmHardwareVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD manufacturer ID Number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mmHardwareVpdEntry 10 }
|
|
|
|
mmHardwareVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD product ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mmHardwareVpdEntry 11 }
|
|
|
|
mmHardwareVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD subsystem manufacturer.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mmHardwareVpdEntry 12 }
|
|
|
|
mmHardwareVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD Common
|
|
Language Equipment Identification (CLEI).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mmHardwareVpdEntry 13 }
|
|
|
|
mmHardwareVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module hardware VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { mmHardwareVpdEntry 14 }
|
|
|
|
-- ********************************************************************************
|
|
-- Management Module Interposer Hardware VPD
|
|
-- ********************************************************************************
|
|
|
|
mmInpHardwareVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MmInpHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the management module interposer hardware components.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mmHardwareVpd 2 }
|
|
|
|
mmInpHardwareVpdEntry OBJECT-TYPE
|
|
SYNTAX MmInpHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module Interposer hardware VPD entry.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
INDEX { mmInpHardwareVpdIndex }
|
|
::= { mmInpHardwareVpdTable 1 }
|
|
|
|
MmInpHardwareVpdEntry ::= SEQUENCE {
|
|
mmInpHardwareVpdIndex INTEGER,
|
|
mmInpHardwareVpdBayNumber OCTET STRING,
|
|
mmInpHardwareVpdManufacturingId OCTET STRING,
|
|
mmInpHardwareVpdFruNumber OCTET STRING,
|
|
mmInpHardwareVpdHardwareRevision INTEGER,
|
|
mmInpHardwareVpdUuid OCTET STRING,
|
|
mmInpHardwareVpdManufDate OCTET STRING,
|
|
mmInpHardwareVpdPartNumber OCTET STRING,
|
|
mmInpHardwareVpdFruSerial OCTET STRING,
|
|
mmInpHardwareVpdManufacturingIDNumber OCTET STRING,
|
|
mmInpHardwareVpdProductId OCTET STRING,
|
|
mmInpHardwareVpdSubManufacturerId OCTET STRING,
|
|
mmInpHardwareVpdClei OCTET STRING,
|
|
mmInpHardwareVpdHardwareRevisionString OCTET STRING
|
|
}
|
|
|
|
mmInpHardwareVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module Interposer hardware VPD index.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mmInpHardwareVpdEntry 1 }
|
|
|
|
mmInpHardwareVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module Interposer hardware VPD Bay number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mmInpHardwareVpdEntry 2 }
|
|
|
|
mmInpHardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module Interposer hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mmInpHardwareVpdEntry 3 }
|
|
|
|
mmInpHardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module Interposer hardware VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mmInpHardwareVpdEntry 4 }
|
|
|
|
|
|
mmInpHardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module Interposer hardware VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { mmInpHardwareVpdEntry 5 }
|
|
|
|
mmInpHardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module Interposer hardware VPD UUID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mmInpHardwareVpdEntry 6 }
|
|
|
|
mmInpHardwareVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module Interposer hardware VPD manufacture date.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mmInpHardwareVpdEntry 7 }
|
|
|
|
mmInpHardwareVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module Interposer hardware VPD Part number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mmInpHardwareVpdEntry 8 }
|
|
|
|
mmInpHardwareVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module Interposer hardware VPD FRU serial number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mmInpHardwareVpdEntry 9 }
|
|
|
|
mmInpHardwareVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module Interposer hardware VPD manufacturer ID Number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mmInpHardwareVpdEntry 10 }
|
|
|
|
mmInpHardwareVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module Interposer hardware VPD product ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mmInpHardwareVpdEntry 11 }
|
|
|
|
mmInpHardwareVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module Interposer hardware VPD subsystem manufacturer.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mmInpHardwareVpdEntry 12 }
|
|
|
|
mmInpHardwareVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module Interposer hardware VPD Common
|
|
Language Equipment Identification (CLEI).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mmInpHardwareVpdEntry 13 }
|
|
|
|
mmInpHardwareVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module Interposer hardware VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only.
|
|
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this version of this MIB object should be used."
|
|
::= { mmInpHardwareVpdEntry 14 }
|
|
|
|
-- ********************************************************************************
|
|
-- System Firmware Level VPD
|
|
-- ********************************************************************************
|
|
mmFirmwareVpd OBJECT IDENTIFIER ::= { vpdInformation 3 }
|
|
|
|
-- ********************************************************************************
|
|
-- MM Firmware VPD
|
|
-- ********************************************************************************
|
|
mmMainApplVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MmMainApplVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of MM Firmware VPD."
|
|
::= { mmFirmwareVpd 1 }
|
|
|
|
mmMainApplVpdEntry OBJECT-TYPE
|
|
SYNTAX MmMainApplVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM Firmware VPD entry."
|
|
INDEX { mmMainApplVpdIndex }
|
|
::= { mmMainApplVpdTable 1 }
|
|
|
|
|
|
MmMainApplVpdEntry ::= SEQUENCE {
|
|
mmMainApplVpdIndex INTEGER,
|
|
mmMainApplVpdName OCTET STRING,
|
|
mmMainApplVpdBuildId OCTET STRING,
|
|
mmMainApplVpdRevisonNumber OCTET STRING,
|
|
mmMainApplVpdFilename OCTET STRING,
|
|
mmMainApplVpdBuildDate OCTET STRING
|
|
}
|
|
|
|
|
|
mmMainApplVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD index."
|
|
::= { mmMainApplVpdEntry 1 }
|
|
|
|
mmMainApplVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD name description.
|
|
'AMM firmware' indicates the running firmware of the MM.
|
|
'AMM firmware (pending restart)' indicates the flashed
|
|
firmware of the MM which will become active after the
|
|
next restart."
|
|
::= { mmMainApplVpdEntry 2 }
|
|
|
|
mmMainApplVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD build identification."
|
|
::= { mmMainApplVpdEntry 3 }
|
|
|
|
mmMainApplVpdRevisonNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD revision number."
|
|
::= { mmMainApplVpdEntry 4 }
|
|
|
|
mmMainApplVpdFilename OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD file name."
|
|
::= { mmMainApplVpdEntry 5 }
|
|
|
|
mmMainApplVpdBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware VPD build date."
|
|
::= { mmMainApplVpdEntry 6 }
|
|
|
|
-- ********************************************************************************
|
|
-- MM Firmware VPD
|
|
-- ********************************************************************************
|
|
mmBootROMVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MmBootROMVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Table of MM Firmware VPD.
|
|
|
|
NOTE: This MIB object is for MM only.
|
|
NOTE: This table is deprecated and no longer supported."
|
|
::= { mmFirmwareVpd 2 }
|
|
|
|
mmBootROMVpdEntry OBJECT-TYPE
|
|
SYNTAX MmBootROMVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"MM Firmware VPD entry.
|
|
|
|
NOTE: This MIB object is for MM only.
|
|
NOTE: This table is deprecated and no longer supported."
|
|
INDEX { mmBootROMVpdIndex }
|
|
::= { mmBootROMVpdTable 1 }
|
|
|
|
|
|
MmBootROMVpdEntry ::= SEQUENCE {
|
|
mmBootROMVpdIndex INTEGER, --deprecated
|
|
mmBootROMVpdName OCTET STRING, --deprecated
|
|
mmBootROMVpdBuildId OCTET STRING, --deprecated
|
|
mmBootROMVpdRevisonNumber OCTET STRING, --deprecated
|
|
mmBootROMVpdFilename OCTET STRING, --deprecated
|
|
mmBootROMVpdBuildDate OCTET STRING --deprecated
|
|
}
|
|
|
|
|
|
mmBootROMVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD index.
|
|
|
|
NOTE: This MIB object is for MM only.
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmBootROMVpdEntry 1 }
|
|
|
|
mmBootROMVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD name description.
|
|
|
|
NOTE: This MIB object is for MM only.
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmBootROMVpdEntry 2 }
|
|
|
|
mmBootROMVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD build identification.
|
|
|
|
NOTE: This MIB object is for MM only.
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmBootROMVpdEntry 3 }
|
|
|
|
mmBootROMVpdRevisonNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD revision number.
|
|
|
|
NOTE: This MIB object is for MM only.
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmBootROMVpdEntry 4 }
|
|
|
|
mmBootROMVpdFilename OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD file name.
|
|
|
|
NOTE: This MIB object is for MM only.
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmBootROMVpdEntry 5 }
|
|
|
|
mmBootROMVpdBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD build date.
|
|
|
|
NOTE: This MIB object is for MM only.
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmBootROMVpdEntry 6 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- MM Firmware VPD
|
|
-- ********************************************************************************
|
|
mmRemoteControlVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MmRemoteControlVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Table of MM Firmware VPD.
|
|
NOTE: This MIB object is for MM only.
|
|
NOTE: This table is deprecated and no longer supported."
|
|
::= { mmFirmwareVpd 3 }
|
|
|
|
mmRemoteControlVpdEntry OBJECT-TYPE
|
|
SYNTAX MmRemoteControlVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"MM Firmware VPD entry.
|
|
|
|
NOTE: This table is deprecated and no longer supported."
|
|
INDEX { mmRemoteControlVpdIndex }
|
|
::= { mmRemoteControlVpdTable 1 }
|
|
|
|
|
|
MmRemoteControlVpdEntry ::= SEQUENCE {
|
|
mmRemoteControlVpdIndex INTEGER, --deprecated
|
|
mmRemoteControlVpdName OCTET STRING, --deprecated
|
|
mmRemoteControlVpdBuildId OCTET STRING, --deprecated
|
|
mmRemoteControlVpdRevisonNumber OCTET STRING, --deprecated
|
|
mmRemoteControlVpdFilename OCTET STRING, --deprecated
|
|
mmRemoteControlVpdBuildDate OCTET STRING --deprecated
|
|
}
|
|
|
|
|
|
mmRemoteControlVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD index.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmRemoteControlVpdEntry 1 }
|
|
|
|
mmRemoteControlVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD name description.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmRemoteControlVpdEntry 2 }
|
|
|
|
mmRemoteControlVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD build identification.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmRemoteControlVpdEntry 3 }
|
|
|
|
mmRemoteControlVpdRevisonNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD revision number.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmRemoteControlVpdEntry 4 }
|
|
|
|
mmRemoteControlVpdFilename OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD file name.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmRemoteControlVpdEntry 5 }
|
|
|
|
mmRemoteControlVpdBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD build date.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmRemoteControlVpdEntry 6 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- MM Firmware VPD
|
|
-- ********************************************************************************
|
|
mmPS2toUSBConvVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MmPS2toUSBConvVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Table of MM Firmware VPD.
|
|
NOTE: This MIB object is for MM only.
|
|
NOTE: This table is deprecated and no longer supported."
|
|
::= { mmFirmwareVpd 4 }
|
|
|
|
mmPS2toUSBConvVpdEntry OBJECT-TYPE
|
|
SYNTAX MmPS2toUSBConvVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"MM Firmware VPD entry.
|
|
NOTE: This table is deprecated and no longer supported."
|
|
INDEX { mmPS2toUSBConvVpdIndex }
|
|
::= { mmPS2toUSBConvVpdTable 1 }
|
|
|
|
|
|
MmPS2toUSBConvVpdEntry ::= SEQUENCE {
|
|
mmPS2toUSBConvVpdIndex INTEGER, --deprecated
|
|
mmPS2toUSBConvVpdName OCTET STRING, --deprecated
|
|
mmPS2toUSBConvVpdBuildId OCTET STRING, --deprecated
|
|
mmPS2toUSBConvVpdRevisonNumber OCTET STRING, --deprecated
|
|
mmPS2toUSBConvVpdFilename OCTET STRING, --deprecated
|
|
mmPS2toUSBConvVpdBuildDate OCTET STRING --deprecated
|
|
}
|
|
|
|
|
|
mmPS2toUSBConvVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD index.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmPS2toUSBConvVpdEntry 1 }
|
|
|
|
mmPS2toUSBConvVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD name description.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmPS2toUSBConvVpdEntry 2 }
|
|
|
|
mmPS2toUSBConvVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD build identification.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmPS2toUSBConvVpdEntry 3 }
|
|
|
|
mmPS2toUSBConvVpdRevisonNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD revision number.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmPS2toUSBConvVpdEntry 4 }
|
|
|
|
mmPS2toUSBConvVpdFilename OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD file name.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmPS2toUSBConvVpdEntry 5 }
|
|
|
|
mmPS2toUSBConvVpdBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD build date.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmPS2toUSBConvVpdEntry 6 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- MM Firmware VPD
|
|
-- ********************************************************************************
|
|
mmToUSBIntfVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MmToUSBIntfVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Table of MM Firmware VPD.
|
|
NOTE: This MIB object is for MM only.
|
|
NOTE: This table is deprecated and no longer supported."
|
|
::= { mmFirmwareVpd 5 }
|
|
|
|
mmToUSBIntfVpdEntry OBJECT-TYPE
|
|
SYNTAX MmToUSBIntfVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"MM Firmware VPD entry.
|
|
|
|
NOTE: This table is deprecated and no longer supported."
|
|
INDEX { mmToUSBIntfVpdIndex }
|
|
::= { mmToUSBIntfVpdTable 1 }
|
|
|
|
|
|
MmToUSBIntfVpdEntry ::= SEQUENCE {
|
|
mmToUSBIntfVpdIndex INTEGER, --deprecated
|
|
mmToUSBIntfVpdName OCTET STRING, --deprecated
|
|
mmToUSBIntfVpdBuildId OCTET STRING, --deprecated
|
|
mmToUSBIntfVpdRevisonNumber OCTET STRING, --deprecated
|
|
mmToUSBIntfVpdFilename OCTET STRING, --deprecated
|
|
mmToUSBIntfVpdBuildDate OCTET STRING --deprecated
|
|
}
|
|
|
|
|
|
mmToUSBIntfVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD index.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmToUSBIntfVpdEntry 1 }
|
|
|
|
mmToUSBIntfVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD name description.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmToUSBIntfVpdEntry 2 }
|
|
|
|
mmToUSBIntfVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD build identification.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmToUSBIntfVpdEntry 3 }
|
|
|
|
mmToUSBIntfVpdRevisonNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD revision number.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmToUSBIntfVpdEntry 4 }
|
|
|
|
mmToUSBIntfVpdFilename OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD file name.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmToUSBIntfVpdEntry 5 }
|
|
|
|
mmToUSBIntfVpdBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Firmware VPD build date.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { mmToUSBIntfVpdEntry 6 }
|
|
|
|
-- ********************************************************************************
|
|
-- System Component Level VPD Activity log
|
|
-- ********************************************************************************
|
|
inventoryManagementActivityVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF InventoryManagementActivityVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of system component hardware VPD activity log.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { vpdInformation 22 }
|
|
|
|
inventoryManagementActivityVpdEntry OBJECT-TYPE
|
|
SYNTAX InventoryManagementActivityVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component hardware VPD activity log entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
INDEX { componentLevelActivityVpdIndex }
|
|
::= { inventoryManagementActivityVpdTable 1 }
|
|
|
|
InventoryManagementActivityVpdEntry ::= SEQUENCE {
|
|
componentLevelActivityVpdIndex INTEGER,
|
|
componentLevelActivityVpdFruNumber OCTET STRING,
|
|
componentLevelActivityVpdSerialNumber OCTET STRING,
|
|
componentLevelActivityVpdManufacturingId OCTET STRING,
|
|
componentLevelActivityVpdBayNumber OCTET STRING,
|
|
componentLevelActivityVpdAction OCTET STRING,
|
|
componentLevelActivityVpdTimestamp OCTET STRING,
|
|
componentLevelActivityVpdModuleName OCTET STRING
|
|
}
|
|
|
|
componentLevelActivityVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD activity log index.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { inventoryManagementActivityVpdEntry 1 }
|
|
|
|
componentLevelActivityVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD activity log FRU number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { inventoryManagementActivityVpdEntry 2 }
|
|
|
|
componentLevelActivityVpdSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD activity log serial number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { inventoryManagementActivityVpdEntry 3 }
|
|
|
|
componentLevelActivityVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD activity log manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { inventoryManagementActivityVpdEntry 4 }
|
|
|
|
componentLevelActivityVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD activity log Bay number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { inventoryManagementActivityVpdEntry 5 }
|
|
|
|
componentLevelActivityVpdAction OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD activity log action (added/removed).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= {inventoryManagementActivityVpdEntry 9 }
|
|
|
|
componentLevelActivityVpdTimestamp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System component level VPD activity log timestamp.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { inventoryManagementActivityVpdEntry 10 }
|
|
|
|
componentLevelActivityVpdModuleName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module name which this row is associated with.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { inventoryManagementActivityVpdEntry 12 }
|
|
|
|
-- ********************************************************************************
|
|
-- Blade Hardware VPD
|
|
-- ********************************************************************************
|
|
bladeHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 4 }
|
|
|
|
bladeHardwareVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of VPD information for the blade hardware components.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpd 1 }
|
|
|
|
bladeHardwareVpdEntry OBJECT-TYPE
|
|
SYNTAX BladeHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
INDEX { bladeHardwareVpdIndex }
|
|
::= { bladeHardwareVpdTable 1 }
|
|
|
|
BladeHardwareVpdEntry ::= SEQUENCE {
|
|
bladeHardwareVpdIndex INTEGER,
|
|
bladeHardwareVpdBayNumber OCTET STRING,
|
|
bladeHardwareVpdManufacturingId OCTET STRING,
|
|
bladeHardwareVpdFruNumber OCTET STRING,
|
|
bladeHardwareVpdHardwareRevision INTEGER,
|
|
bladeHardwareVpdSerialNumber OCTET STRING,
|
|
bladeHardwareVpdMachineType OCTET STRING,
|
|
bladeHardwareVpdUuid OCTET STRING,
|
|
bladeHardwareVpdManufDate OCTET STRING,
|
|
bladeHardwareVpdPartNumber OCTET STRING,
|
|
bladeHardwareVpdFruSerial OCTET STRING,
|
|
bladeHardwareVpdMachineModel OCTET STRING,
|
|
bladeHardwareVpdManufacturingIDNumber OCTET STRING,
|
|
bladeHardwareVpdProductId OCTET STRING,
|
|
bladeHardwareVpdSubManufacturerId OCTET STRING,
|
|
bladeHardwareVpdClei OCTET STRING,
|
|
bladeHardwareVpdHardwareRevisionString OCTET STRING,
|
|
bladeDaughterVpdCardType INTEGER,
|
|
bladeDaughterVpdManufacturingId OCTET STRING,
|
|
bladeDaughterVpdFruNumber OCTET STRING,
|
|
bladeDaughterVpdHardwareRevision INTEGER,
|
|
bladeDaughterVpdSerialNumber OCTET STRING,
|
|
bladeDaughterVpdMachineType OCTET STRING,
|
|
bladeDaughterVpdUuid OCTET STRING,
|
|
bladeDaughterVpdManufDate OCTET STRING,
|
|
bladeDaughterVpdPartNumber OCTET STRING,
|
|
bladeDaughterVpdFruSerial OCTET STRING,
|
|
bladeDaughterVpdManufacturingIDNumber OCTET STRING,
|
|
bladeDaughterVpdProductId OCTET STRING,
|
|
bladeDaughterVpdSubManufacturerId OCTET STRING,
|
|
bladeDaughterVpdClei OCTET STRING,
|
|
bladeDaughterVpdHardwareRevisionString OCTET STRING
|
|
}
|
|
|
|
bladeHardwareVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD index.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 1 }
|
|
|
|
bladeHardwareVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD Bay number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 2 }
|
|
|
|
bladeHardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 3 }
|
|
|
|
bladeHardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 4 }
|
|
|
|
|
|
bladeHardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { bladeHardwareVpdEntry 5 }
|
|
|
|
bladeHardwareVpdSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD serial number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 6 }
|
|
|
|
bladeHardwareVpdMachineType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD machine type.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 7 }
|
|
|
|
bladeHardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD UUID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 8 }
|
|
|
|
bladeHardwareVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD Manufacture Date.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 9 }
|
|
|
|
bladeHardwareVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD Part number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 10 }
|
|
|
|
bladeHardwareVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD FRU serial number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 11 }
|
|
|
|
bladeHardwareVpdMachineModel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD machine model.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 12 }
|
|
|
|
bladeHardwareVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD Manufacturer ID Number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 13 }
|
|
|
|
bladeHardwareVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD product ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 14 }
|
|
|
|
bladeHardwareVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD subsystem manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 15 }
|
|
|
|
bladeHardwareVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD Common Language Equipment Identifier (CLEI).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 16 }
|
|
|
|
bladeHardwareVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade hardware VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { bladeHardwareVpdEntry 17 }
|
|
|
|
bladeDaughterVpdCardType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
networkExpansion(1),
|
|
storageExpansion(2),
|
|
pciExpansion(3),
|
|
genericExpansion(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) VPD type.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 20 }
|
|
|
|
bladeDaughterVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 21 }
|
|
|
|
bladeDaughterVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 22 }
|
|
|
|
|
|
bladeDaughterVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { bladeHardwareVpdEntry 23 }
|
|
|
|
bladeDaughterVpdSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) VPD Serial number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 24 }
|
|
|
|
bladeDaughterVpdMachineType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) VPD Machine type.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 25 }
|
|
|
|
bladeDaughterVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) VPD UUID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 26 }
|
|
|
|
bladeDaughterVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) VPD Manufacture date.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 27 }
|
|
|
|
bladeDaughterVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) VPD Part number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 28 }
|
|
|
|
bladeDaughterVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) VPD FRU Serial.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 29 }
|
|
|
|
bladeDaughterVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) VPD manufacturer ID Number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 30 }
|
|
|
|
bladeDaughterVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) VPD product ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 31 }
|
|
|
|
bladeDaughterVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) VPD subsystem manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 32 }
|
|
|
|
bladeDaughterVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) VPD
|
|
Common Language Equipment Identifier (CLEI).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpdEntry 33 }
|
|
|
|
bladeDaughterVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { bladeHardwareVpdEntry 34 }
|
|
|
|
-- ********************************************************************************
|
|
-- Blade MAC Address VPD
|
|
-- ********************************************************************************
|
|
|
|
bladeMACAddressVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeMACAddressVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of MAC addresses of the blade and its expansion cards (daughter cards).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpd 2 }
|
|
|
|
bladeMACAddressVpdEntry OBJECT-TYPE
|
|
SYNTAX BladeMACAddressVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade MAC address entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
INDEX { bladeMACAddressVpdIndex }
|
|
::= { bladeMACAddressVpdTable 1 }
|
|
|
|
|
|
BladeMACAddressVpdEntry ::= SEQUENCE {
|
|
bladeMACAddressVpdIndex INTEGER,
|
|
bladeMACAddress1Vpd OCTET STRING,
|
|
bladeMACAddress2Vpd OCTET STRING,
|
|
bladeMACAddress3Vpd OCTET STRING,
|
|
bladeMACAddress4Vpd OCTET STRING,
|
|
bladeMACAddress5Vpd OCTET STRING,
|
|
bladeMACAddress6Vpd OCTET STRING,
|
|
bladeMACAddress7Vpd OCTET STRING,
|
|
bladeMACAddress8Vpd OCTET STRING,
|
|
bladeDaughterCard1MACAddress1Vpd OCTET STRING,
|
|
bladeDaughterCard1MACAddress2Vpd OCTET STRING,
|
|
bladeDaughterCard1MACAddress3Vpd OCTET STRING,
|
|
bladeDaughterCard1MACAddress4Vpd OCTET STRING,
|
|
bladeDaughterCard1MACAddress5Vpd OCTET STRING,
|
|
bladeDaughterCard1MACAddress6Vpd OCTET STRING,
|
|
bladeDaughterCard1MACAddress7Vpd OCTET STRING,
|
|
bladeDaughterCard1MACAddress8Vpd OCTET STRING,
|
|
bladeDaughterCard2MACAddress1Vpd OCTET STRING,
|
|
bladeDaughterCard2MACAddress2Vpd OCTET STRING,
|
|
bladeDaughterCard2MACAddress3Vpd OCTET STRING,
|
|
bladeDaughterCard2MACAddress4Vpd OCTET STRING,
|
|
bladeDaughterCard2MACAddress5Vpd OCTET STRING,
|
|
bladeDaughterCard2MACAddress6Vpd OCTET STRING,
|
|
bladeDaughterCard2MACAddress7Vpd OCTET STRING,
|
|
bladeDaughterCard2MACAddress8Vpd OCTET STRING,
|
|
bladeDaughterCard3MACAddress1Vpd OCTET STRING,
|
|
bladeDaughterCard3MACAddress2Vpd OCTET STRING,
|
|
bladeDaughterCard3MACAddress3Vpd OCTET STRING,
|
|
bladeDaughterCard3MACAddress4Vpd OCTET STRING,
|
|
bladeDaughterCard3MACAddress5Vpd OCTET STRING,
|
|
bladeDaughterCard3MACAddress6Vpd OCTET STRING,
|
|
bladeDaughterCard3MACAddress7Vpd OCTET STRING,
|
|
bladeDaughterCard3MACAddress8Vpd OCTET STRING,
|
|
bladeDaughterCard4MACAddress1Vpd OCTET STRING,
|
|
bladeDaughterCard4MACAddress2Vpd OCTET STRING,
|
|
bladeDaughterCard4MACAddress3Vpd OCTET STRING,
|
|
bladeDaughterCard4MACAddress4Vpd OCTET STRING,
|
|
bladeDaughterCard4MACAddress5Vpd OCTET STRING,
|
|
bladeDaughterCard4MACAddress6Vpd OCTET STRING,
|
|
bladeDaughterCard4MACAddress7Vpd OCTET STRING,
|
|
bladeDaughterCard4MACAddress8Vpd OCTET STRING,
|
|
bladeDaughterCard5MACAddress1Vpd OCTET STRING,
|
|
bladeDaughterCard5MACAddress2Vpd OCTET STRING,
|
|
bladeDaughterCard5MACAddress3Vpd OCTET STRING,
|
|
bladeDaughterCard5MACAddress4Vpd OCTET STRING,
|
|
bladeDaughterCard5MACAddress5Vpd OCTET STRING,
|
|
bladeDaughterCard5MACAddress6Vpd OCTET STRING,
|
|
bladeDaughterCard5MACAddress7Vpd OCTET STRING,
|
|
bladeDaughterCard5MACAddress8Vpd OCTET STRING,
|
|
bladeHSDaughterCard1MACAddress1Vpd OCTET STRING,
|
|
bladeHSDaughterCard1MACAddress2Vpd OCTET STRING,
|
|
bladeHSDaughterCard1MACAddress3Vpd OCTET STRING,
|
|
bladeHSDaughterCard1MACAddress4Vpd OCTET STRING,
|
|
bladeHSDaughterCard1MACAddress5Vpd OCTET STRING,
|
|
bladeHSDaughterCard1MACAddress6Vpd OCTET STRING,
|
|
bladeHSDaughterCard1MACAddress7Vpd OCTET STRING,
|
|
bladeHSDaughterCard1MACAddress8Vpd OCTET STRING,
|
|
bladeHSDaughterCard1MACAddress9Vpd OCTET STRING,
|
|
bladeHSDaughterCard1MACAddress10Vpd OCTET STRING,
|
|
bladeHSDaughterCard1MACAddress11Vpd OCTET STRING,
|
|
bladeHSDaughterCard1MACAddress12Vpd OCTET STRING,
|
|
bladeHSDaughterCard1MACAddress13Vpd OCTET STRING,
|
|
bladeHSDaughterCard1MACAddress14Vpd OCTET STRING,
|
|
bladeHSDaughterCard1MACAddress15Vpd OCTET STRING,
|
|
bladeHSDaughterCard1MACAddress16Vpd OCTET STRING,
|
|
bladeSideCardMACAddress1Vpd OCTET STRING,
|
|
bladeSideCardMACAddress2Vpd OCTET STRING,
|
|
bladeSideCardMACAddress3Vpd OCTET STRING,
|
|
bladeSideCardMACAddress4Vpd OCTET STRING,
|
|
bladeSideCardMACAddress5Vpd OCTET STRING,
|
|
bladeSideCardMACAddress6Vpd OCTET STRING,
|
|
bladeSideCardMACAddress7Vpd OCTET STRING,
|
|
bladeSideCardMACAddress8Vpd OCTET STRING
|
|
}
|
|
|
|
bladeMACAddressVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade index.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 1 }
|
|
|
|
bladeMACAddress1Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade MAC address 1.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 2 }
|
|
|
|
bladeMACAddress2Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade MAC address 2.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 3 }
|
|
|
|
bladeMACAddress3Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade MAC address 3.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 4 }
|
|
|
|
bladeMACAddress4Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade MAC address 4.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 5 }
|
|
|
|
bladeMACAddress5Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade MAC address 5.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 6 }
|
|
|
|
bladeMACAddress6Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade MAC address 6.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 7 }
|
|
|
|
bladeMACAddress7Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade MAC address 7.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 8 }
|
|
|
|
bladeMACAddress8Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade MAC address 8.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 9 }
|
|
|
|
bladeDaughterCard1MACAddress1Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 1 MAC address 1.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 10 }
|
|
|
|
bladeDaughterCard1MACAddress2Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 1 MAC address 2.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 11 }
|
|
|
|
bladeDaughterCard1MACAddress3Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 1 MAC address 3.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 12 }
|
|
|
|
bladeDaughterCard1MACAddress4Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 1 MAC address 4.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 13 }
|
|
|
|
bladeDaughterCard1MACAddress5Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 1 MAC address 5.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 14 }
|
|
|
|
bladeDaughterCard1MACAddress6Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 1 MAC address 6.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 15 }
|
|
|
|
bladeDaughterCard1MACAddress7Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 1 MAC address 7.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 16 }
|
|
|
|
bladeDaughterCard1MACAddress8Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 1 MAC address 8.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 17 }
|
|
|
|
bladeDaughterCard2MACAddress1Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 2 MAC address 1.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 18 }
|
|
|
|
bladeDaughterCard2MACAddress2Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 2 MAC address 2.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 19 }
|
|
|
|
bladeDaughterCard2MACAddress3Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 2 MAC address 3.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 20 }
|
|
|
|
bladeDaughterCard2MACAddress4Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 2 MAC address 4.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 21 }
|
|
|
|
bladeDaughterCard2MACAddress5Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 2 MAC address 5.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 22 }
|
|
|
|
bladeDaughterCard2MACAddress6Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 2 MAC address 6.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 23 }
|
|
|
|
bladeDaughterCard2MACAddress7Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 2 MAC address 7.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 24 }
|
|
|
|
bladeDaughterCard2MACAddress8Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 2 MAC address 8.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 25 }
|
|
|
|
bladeDaughterCard3MACAddress1Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 3 MAC address 1.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 26 }
|
|
|
|
bladeDaughterCard3MACAddress2Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 3 MAC address 2.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 27 }
|
|
|
|
bladeDaughterCard3MACAddress3Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 3 MAC address 3.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 28 }
|
|
|
|
bladeDaughterCard3MACAddress4Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 3 MAC address 4.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 29 }
|
|
|
|
bladeDaughterCard3MACAddress5Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 3 MAC address 5.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 30 }
|
|
|
|
bladeDaughterCard3MACAddress6Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 3 MAC address 6.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 31 }
|
|
|
|
bladeDaughterCard3MACAddress7Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 3 MAC address 7.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 32 }
|
|
|
|
bladeDaughterCard3MACAddress8Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 3 MAC address 8.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 33 }
|
|
|
|
bladeDaughterCard4MACAddress1Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 4 MAC address 1.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 34 }
|
|
|
|
bladeDaughterCard4MACAddress2Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 4 MAC address 2.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 35 }
|
|
|
|
bladeDaughterCard4MACAddress3Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 4 MAC address 3.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 36 }
|
|
|
|
bladeDaughterCard4MACAddress4Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 4 MAC address 4.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 37 }
|
|
|
|
bladeDaughterCard4MACAddress5Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 4 MAC address 5.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 38 }
|
|
|
|
bladeDaughterCard4MACAddress6Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 4 MAC address 6.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 39 }
|
|
|
|
bladeDaughterCard4MACAddress7Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 4 MAC address 7.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 40 }
|
|
|
|
bladeDaughterCard4MACAddress8Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 4 MAC address 8.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 41 }
|
|
|
|
bladeDaughterCard5MACAddress1Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 5 MAC address 1.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 42 }
|
|
|
|
bladeDaughterCard5MACAddress2Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 5 MAC address 2.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 43 }
|
|
|
|
bladeDaughterCard5MACAddress3Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 5 MAC address 3.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 44}
|
|
|
|
bladeDaughterCard5MACAddress4Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 5 MAC address 4.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 45 }
|
|
|
|
bladeDaughterCard5MACAddress5Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 5 MAC address 5.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 46 }
|
|
|
|
bladeDaughterCard5MACAddress6Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 5 MAC address 6.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 47 }
|
|
|
|
bladeDaughterCard5MACAddress7Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 5 MAC address 7.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 48 }
|
|
|
|
bladeDaughterCard5MACAddress8Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) 5 MAC address 8.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 49 }
|
|
|
|
bladeHSDaughterCard1MACAddress1Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade high speed expansion card (daughter card) 1 MAC address 1.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 100 }
|
|
|
|
bladeHSDaughterCard1MACAddress2Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade high speed expansion card (daughter card) 1 MAC address 2.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 101 }
|
|
|
|
bladeHSDaughterCard1MACAddress3Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade high speed expansion card (daughter card) 1 MAC address 3.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 102}
|
|
|
|
bladeHSDaughterCard1MACAddress4Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade high speed expansion card (daughter card) 1 MAC address 4.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 103 }
|
|
|
|
bladeHSDaughterCard1MACAddress5Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade high speed expansion card (daughter card) 1 MAC address 5.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 104 }
|
|
|
|
bladeHSDaughterCard1MACAddress6Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade high speed expansion card (daughter card) 1 MAC address 6.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 105 }
|
|
|
|
bladeHSDaughterCard1MACAddress7Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade high speed expansion card (daughter card) 1 MAC address 7.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 106 }
|
|
|
|
bladeHSDaughterCard1MACAddress8Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade high speed expansion card (daughter card) 1 MAC address 8.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 107 }
|
|
|
|
bladeHSDaughterCard1MACAddress9Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade high speed expansion card (daughter card) 1 MAC address 9.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 108 }
|
|
|
|
bladeHSDaughterCard1MACAddress10Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade high speed expansion card (daughter card) 1 MAC address 10.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 109 }
|
|
|
|
bladeHSDaughterCard1MACAddress11Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade high speed expansion card (daughter card) 1 MAC address 11.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 110 }
|
|
|
|
bladeHSDaughterCard1MACAddress12Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade high speed expansion card (daughter card) 1 MAC address 12.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 111 }
|
|
|
|
bladeHSDaughterCard1MACAddress13Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade high speed expansion card (daughter card) 1 MAC address 13.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 112 }
|
|
|
|
bladeHSDaughterCard1MACAddress14Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade high speed expansion card (daughter card) 1 MAC address 14.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 113 }
|
|
|
|
bladeHSDaughterCard1MACAddress15Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade high speed expansion card (daughter card) 1 MAC address 15.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 114 }
|
|
|
|
bladeHSDaughterCard1MACAddress16Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade high speed expansion card (daughter card) 1 MAC address 16.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 115 }
|
|
|
|
bladeSideCardMACAddress1Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card MAC address 1.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 164 }
|
|
|
|
bladeSideCardMACAddress2Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card MAC address 2.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 165 }
|
|
|
|
bladeSideCardMACAddress3Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card MAC address 3.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 166 }
|
|
|
|
bladeSideCardMACAddress4Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card MAC address 4.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 167 }
|
|
|
|
bladeSideCardMACAddress5Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card MAC address 5.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 168 }
|
|
|
|
bladeSideCardMACAddress6Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card MAC address 6.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 169 }
|
|
|
|
bladeSideCardMACAddress7Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card MAC address 7.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 170 }
|
|
|
|
bladeSideCardMACAddress8Vpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card MAC address 8.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeMACAddressVpdEntry 171 }
|
|
|
|
-- ********************************************************************************
|
|
-- Blade Expansion Board VPD
|
|
-- ********************************************************************************
|
|
|
|
bladeExpBoardVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeExpBoardVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of VPD information for the blade expansion board components.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpd 3 }
|
|
|
|
bladeExpBoardVpdEntry OBJECT-TYPE
|
|
SYNTAX BladeExpBoardVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
INDEX { bladeExpBoardVpdIndex }
|
|
::= { bladeExpBoardVpdTable 1 }
|
|
|
|
BladeExpBoardVpdEntry ::= SEQUENCE {
|
|
bladeExpBoardVpdIndex INTEGER,
|
|
bladeExpBoardVpdBayNumber OCTET STRING,
|
|
bladeExpBoardVpdManufacturingId OCTET STRING,
|
|
bladeExpBoardVpdFruNumber OCTET STRING,
|
|
bladeExpBoardVpdHardwareRevision INTEGER,
|
|
bladeExpBoardVpdSerialNumber OCTET STRING,
|
|
bladeExpBoardVpdMachineType OCTET STRING,
|
|
bladeExpBoardVpdUuid OCTET STRING,
|
|
bladeExpBoardVpdManufDate OCTET STRING,
|
|
bladeExpBoardVpdPartNumber OCTET STRING,
|
|
bladeExpBoardVpdFruSerial OCTET STRING,
|
|
bladeExpBoardVpdMachineModel OCTET STRING,
|
|
bladeExpBoardVpdManufacturingIDNumber OCTET STRING,
|
|
bladeExpBoardVpdProductId OCTET STRING,
|
|
bladeExpBoardVpdSubManufacturerId OCTET STRING,
|
|
bladeExpBoardVpdClei OCTET STRING,
|
|
bladeExpBoardVpdBladeBayNumber OCTET STRING,
|
|
bladeExpBoardVpdCardType INTEGER,
|
|
bladeExpBoardVpdCardSubType INTEGER,
|
|
bladeExpBoardVpdHardwareRevisionString OCTET STRING
|
|
}
|
|
|
|
bladeExpBoardVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD index.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpBoardVpdEntry 1 }
|
|
|
|
bladeExpBoardVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD Bay number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpBoardVpdEntry 2 }
|
|
|
|
bladeExpBoardVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpBoardVpdEntry 3 }
|
|
|
|
bladeExpBoardVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpBoardVpdEntry 4 }
|
|
|
|
|
|
bladeExpBoardVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { bladeExpBoardVpdEntry 5 }
|
|
|
|
bladeExpBoardVpdSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD serial number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpBoardVpdEntry 6 }
|
|
|
|
bladeExpBoardVpdMachineType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD machine type.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpBoardVpdEntry 7 }
|
|
|
|
bladeExpBoardVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD UUID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpBoardVpdEntry 8 }
|
|
|
|
bladeExpBoardVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD Manufacture Date.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpBoardVpdEntry 9 }
|
|
|
|
bladeExpBoardVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD Part number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpBoardVpdEntry 10 }
|
|
|
|
bladeExpBoardVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD FRU serial number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpBoardVpdEntry 11 }
|
|
|
|
bladeExpBoardVpdMachineModel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD machine model.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpBoardVpdEntry 12 }
|
|
|
|
bladeExpBoardVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD Manufacturer ID Number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpBoardVpdEntry 13 }
|
|
|
|
bladeExpBoardVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD Product ID.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeExpBoardVpdEntry 14 }
|
|
|
|
bladeExpBoardVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD subsystem manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpBoardVpdEntry 15 }
|
|
|
|
bladeExpBoardVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD Common Language Equipment Identifier (CLEI).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpBoardVpdEntry 16 }
|
|
|
|
bladeExpBoardVpdBladeBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade bay number of the blade expansion board.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpBoardVpdEntry 19 }
|
|
|
|
bladeExpBoardVpdCardType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
storageExpansion(1),
|
|
pciExpansion(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD type.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpBoardVpdEntry 20 }
|
|
|
|
bladeExpBoardVpdCardSubType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
bse1(1),
|
|
bse2(2),
|
|
bse3(3),
|
|
peu1(11),
|
|
peu2(12),
|
|
peu3(13),
|
|
bie(21)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD subtype.
|
|
Describes the expansion board type with more granularity.
|
|
bse1,bse2,bse3 = Blade Storage Expansion (1st, 2nd, and 3rd Generations),
|
|
peu1 = PCI Expansion (1st Generation),
|
|
peu2 = PCI Expansion Unit II,
|
|
peu3 = bpe3 = PCI Express Expansion Unit,
|
|
bie= Blade I/O Expansion
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpBoardVpdEntry 21 }
|
|
|
|
bladeExpBoardVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion board VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { bladeExpBoardVpdEntry 22 }
|
|
|
|
-- ********************************************************************************
|
|
-- Blade Side Card VPD
|
|
-- ********************************************************************************
|
|
|
|
bladeSideCardVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeSideCardVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of VPD information for the blade side card components.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpd 4 }
|
|
|
|
bladeSideCardVpdEntry OBJECT-TYPE
|
|
SYNTAX BladeSideCardVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card VPD entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
INDEX { bladeSideCardVpdIndex }
|
|
::= { bladeSideCardVpdTable 1 }
|
|
|
|
BladeSideCardVpdEntry ::= SEQUENCE {
|
|
bladeSideCardVpdIndex INTEGER,
|
|
bladeSideCardVpdBayNumber OCTET STRING,
|
|
bladeSideCardVpdManufacturingId OCTET STRING,
|
|
bladeSideCardVpdFruNumber OCTET STRING,
|
|
bladeSideCardVpdHardwareRevision INTEGER,
|
|
bladeSideCardVpdSerialNumber OCTET STRING,
|
|
bladeSideCardVpdMachineType OCTET STRING,
|
|
bladeSideCardVpdUuid OCTET STRING,
|
|
bladeSideCardVpdManufDate OCTET STRING,
|
|
bladeSideCardVpdPartNumber OCTET STRING,
|
|
bladeSideCardVpdFruSerial OCTET STRING,
|
|
bladeSideCardVpdMachineModel OCTET STRING,
|
|
bladeSideCardVpdManufacturingIDNumber OCTET STRING,
|
|
bladeSideCardVpdProductId OCTET STRING,
|
|
bladeSideCardVpdSubManufacturerId OCTET STRING,
|
|
bladeSideCardVpdClei OCTET STRING,
|
|
bladeSideCardVpdBladeBayNumber OCTET STRING,
|
|
bladeSideCardVpdHardwareRevisionString OCTET STRING
|
|
}
|
|
|
|
bladeSideCardVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card VPD index.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeSideCardVpdEntry 1 }
|
|
|
|
bladeSideCardVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card VPD Bay number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeSideCardVpdEntry 2 }
|
|
|
|
bladeSideCardVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeSideCardVpdEntry 3 }
|
|
|
|
bladeSideCardVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeSideCardVpdEntry 4 }
|
|
|
|
|
|
bladeSideCardVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { bladeSideCardVpdEntry 5 }
|
|
|
|
bladeSideCardVpdSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card VPD serial number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeSideCardVpdEntry 6 }
|
|
|
|
bladeSideCardVpdMachineType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card VPD machine type.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeSideCardVpdEntry 7 }
|
|
|
|
bladeSideCardVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card VPD UUID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeSideCardVpdEntry 8 }
|
|
|
|
bladeSideCardVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card VPD Manufacture Date.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeSideCardVpdEntry 9 }
|
|
|
|
bladeSideCardVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card VPD Part number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeSideCardVpdEntry 10 }
|
|
|
|
bladeSideCardVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card VPD FRU serial number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeSideCardVpdEntry 11 }
|
|
|
|
bladeSideCardVpdMachineModel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card VPD machine model.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeSideCardVpdEntry 12 }
|
|
|
|
bladeSideCardVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card VPD Manufacturer ID Number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeSideCardVpdEntry 13 }
|
|
|
|
bladeSideCardVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card VPD Product ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeSideCardVpdEntry 14 }
|
|
|
|
bladeSideCardVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card VPD subsystem manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeSideCardVpdEntry 15 }
|
|
|
|
bladeSideCardVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card VPD Common Language
|
|
Equipment Identifier (CLEI).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeSideCardVpdEntry 16 }
|
|
|
|
bladeSideCardVpdBladeBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade bay number of the blade side card.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeSideCardVpdEntry 19 }
|
|
|
|
bladeSideCardVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade side card VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { bladeSideCardVpdEntry 20 }
|
|
|
|
-- ********************************************************************************
|
|
-- Blade Expansion Card VPD
|
|
-- ********************************************************************************
|
|
|
|
bladeExpCardVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeExpCardVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of VPD information for the blade expansion card components.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpd 5 }
|
|
|
|
bladeExpCardVpdEntry OBJECT-TYPE
|
|
SYNTAX BladeExpCardVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card VPD entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
INDEX { bladeExpCardVpdIndex }
|
|
::= { bladeExpCardVpdTable 1 }
|
|
|
|
BladeExpCardVpdEntry ::= SEQUENCE {
|
|
bladeExpCardVpdIndex INTEGER,
|
|
bladeExpCardVpdBayNumber OCTET STRING,
|
|
bladeExpCardVpdManufacturingId OCTET STRING,
|
|
bladeExpCardVpdFruNumber OCTET STRING,
|
|
bladeExpCardVpdHardwareRevision INTEGER,
|
|
bladeExpCardVpdSerialNumber OCTET STRING,
|
|
bladeExpCardVpdMachineType OCTET STRING,
|
|
bladeExpCardVpdUuid OCTET STRING,
|
|
bladeExpCardVpdManufDate OCTET STRING,
|
|
bladeExpCardVpdPartNumber OCTET STRING,
|
|
bladeExpCardVpdFruSerial OCTET STRING,
|
|
bladeExpCardVpdMachineModel OCTET STRING,
|
|
bladeExpCardVpdManufacturingIDNumber OCTET STRING,
|
|
bladeExpCardVpdProductId OCTET STRING,
|
|
bladeExpCardVpdSubManufacturerId OCTET STRING,
|
|
bladeExpCardVpdClei OCTET STRING,
|
|
bladeExpCardVpdBladeBayNumber OCTET STRING,
|
|
bladeExpCardVpdCardTypeInfo INTEGER,
|
|
bladeExpCardVpdHighSpeed INTEGER,
|
|
bladeExpCardVpdHardwareRevisionString OCTET STRING
|
|
}
|
|
|
|
bladeExpCardVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card VPD index.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpCardVpdEntry 1 }
|
|
|
|
bladeExpCardVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card VPD Bay number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpCardVpdEntry 2 }
|
|
|
|
bladeExpCardVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpCardVpdEntry 3 }
|
|
|
|
bladeExpCardVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpCardVpdEntry 4 }
|
|
|
|
|
|
bladeExpCardVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { bladeExpCardVpdEntry 5 }
|
|
|
|
bladeExpCardVpdSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card VPD serial number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpCardVpdEntry 6 }
|
|
|
|
bladeExpCardVpdMachineType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card VPD machine type.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpCardVpdEntry 7 }
|
|
|
|
bladeExpCardVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card VPD UUID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpCardVpdEntry 8 }
|
|
|
|
bladeExpCardVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card VPD Manufacture Date.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpCardVpdEntry 9 }
|
|
|
|
bladeExpCardVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card VPD Part number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpCardVpdEntry 10 }
|
|
|
|
bladeExpCardVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card VPD FRU serial number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpCardVpdEntry 11 }
|
|
|
|
bladeExpCardVpdMachineModel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card VPD machine model.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpCardVpdEntry 12 }
|
|
|
|
bladeExpCardVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card VPD Manufacturer ID Number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpCardVpdEntry 13 }
|
|
|
|
bladeExpCardVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card VPD Product ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpCardVpdEntry 14 }
|
|
|
|
bladeExpCardVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card VPD subsystem manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpCardVpdEntry 15 }
|
|
|
|
bladeExpCardVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card VPD Common Language Equipment Identifier (CLEI).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpCardVpdEntry 16 }
|
|
|
|
bladeExpCardVpdBladeBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade bay number of the blade expansion card.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeExpCardVpdEntry 19 }
|
|
|
|
bladeExpCardVpdCardTypeInfo OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
bladeEthernetExpCard(1),
|
|
bladeFiberChannelExpCard(2),
|
|
serialPortExpCard(3),
|
|
bladeOpticalPassThrough(4),
|
|
bladeInfinibandExpCard(5),
|
|
bladeIscsiExpCard(6),
|
|
bladeGenericExpCard(7),
|
|
bladeNetworkCFFeExpCard(8),
|
|
bladeSASConnectivityCard(9),
|
|
bladeSATAConnectivityCard(10),
|
|
bladeNetworkCFFzExpCard(11),
|
|
bladeNetworkCNAExpCard(12),
|
|
bladeSSDExpCard(13),
|
|
bladePCIExp(14),
|
|
bladeGraphicsExp(15),
|
|
bladeIOExp(16),
|
|
bladeMemoryExp(17),
|
|
bladeProcessorExp(18),
|
|
bladeGenericExp(19)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) VPD type code that describes the expansion
|
|
card. For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: The CFFe expansion card is also referred to as a CFFh expansion card."
|
|
::= { bladeExpCardVpdEntry 21 }
|
|
|
|
bladeExpCardVpdHighSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card (daughter card) VPD high speed that indicates whether the
|
|
expansion card is high speed or not. For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeExpCardVpdEntry 22 }
|
|
|
|
bladeExpCardVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade expansion card VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { bladeExpCardVpdEntry 23 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Blade cKVM card VPD
|
|
-- ********************************************************************************
|
|
|
|
bladecKVMCardVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladecKVMCardVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of VPD information for the blade
|
|
concurrent keyboard, video, and mouse (cKVM) card components.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpd 6 }
|
|
|
|
bladecKVMCardVpdEntry OBJECT-TYPE
|
|
SYNTAX BladecKVMCardVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade concurrent keyboard, video, and mouse (cKVM) card VPD entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
INDEX { bladecKVMCardVpdIndex }
|
|
::= { bladecKVMCardVpdTable 1 }
|
|
|
|
BladecKVMCardVpdEntry ::= SEQUENCE {
|
|
bladecKVMCardVpdIndex INTEGER,
|
|
bladecKVMCardVpdBayNumber OCTET STRING,
|
|
bladecKVMCardVpdManufacturingId OCTET STRING,
|
|
bladecKVMCardVpdFruNumber OCTET STRING,
|
|
bladecKVMCardVpdHardwareRevision INTEGER,
|
|
bladecKVMCardVpdSerialNumber OCTET STRING,
|
|
bladecKVMCardVpdMachineType OCTET STRING,
|
|
bladecKVMCardVpdUuid OCTET STRING,
|
|
bladecKVMCardVpdManufDate OCTET STRING,
|
|
bladecKVMCardVpdPartNumber OCTET STRING,
|
|
bladecKVMCardVpdFruSerial OCTET STRING,
|
|
bladecKVMCardVpdMachineModel OCTET STRING,
|
|
bladecKVMCardVpdManufacturingIDNumber OCTET STRING,
|
|
bladecKVMCardVpdProductId OCTET STRING,
|
|
bladecKVMCardVpdSubManufacturerId OCTET STRING,
|
|
bladecKVMCardVpdClei OCTET STRING,
|
|
bladecKVMCardVpdHardwareRevisionString OCTET STRING
|
|
}
|
|
|
|
bladecKVMCardVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade concurrent keyboard mouse video (cKVM) card VPD index.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladecKVMCardVpdEntry 1 }
|
|
|
|
bladecKVMCardVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade concurrent keyboard video mouse (cKVM) card VPD Bay number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladecKVMCardVpdEntry 2 }
|
|
|
|
bladecKVMCardVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade concurrent keyboard video mouse (cKVM) card VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladecKVMCardVpdEntry 3 }
|
|
|
|
bladecKVMCardVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade concurrent keyboard video mouse (cKVM) card VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladecKVMCardVpdEntry 4 }
|
|
|
|
|
|
bladecKVMCardVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade concurrent keyboard video mouse (cKVM) card VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { bladecKVMCardVpdEntry 5 }
|
|
|
|
bladecKVMCardVpdSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade concurrent keyboard video mouse (cKVM) card VPD serial number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladecKVMCardVpdEntry 6 }
|
|
|
|
bladecKVMCardVpdMachineType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade concurrent keyboard video mouse (cKVM) card VPD machine type.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladecKVMCardVpdEntry 7 }
|
|
|
|
bladecKVMCardVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade concurrent keyboard video mouse (cKVM) card VPD UUID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladecKVMCardVpdEntry 8 }
|
|
|
|
bladecKVMCardVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade concurrent keyboard video mouse (cKVM) card VPD Manufacture Date.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladecKVMCardVpdEntry 9 }
|
|
|
|
bladecKVMCardVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade concurrent keyboard video mouse (cKVM) card VPD Part number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladecKVMCardVpdEntry 10 }
|
|
|
|
bladecKVMCardVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade concurrent keyboard video mouse (cKVM) card VPD FRU serial number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladecKVMCardVpdEntry 11 }
|
|
|
|
bladecKVMCardVpdMachineModel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade concurrent keyboard video mouse (cKVM) card VPD machine model.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladecKVMCardVpdEntry 12 }
|
|
|
|
bladecKVMCardVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade concurrent keyboard video mouse (cKVM) card VPD
|
|
manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladecKVMCardVpdEntry 13 }
|
|
|
|
bladecKVMCardVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade concurrent keyboard video mouse (cKVM) card VPD
|
|
Product ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladecKVMCardVpdEntry 14 }
|
|
|
|
bladecKVMCardVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade concurrent keyboard video mouse (cKVM) card VPD
|
|
subsystem manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladecKVMCardVpdEntry 15 }
|
|
|
|
bladecKVMCardVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade concurrent keyboard video mouse (cKVM) card VPD
|
|
Common Language Equipment Identifier (CLEI).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladecKVMCardVpdEntry 16 }
|
|
|
|
bladecKVMCardVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade concurrent keyboard video mouse (cKVM) card VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { bladecKVMCardVpdEntry 17 }
|
|
|
|
-- ********************************************************************************
|
|
-- Table for the blade and expansion card WWN/GUIDs
|
|
-- ********************************************************************************
|
|
bladeAndExpCardWwnGuidVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeAndExpCardWwnGuidVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of World Wide Names (WWN), Global Unique IDs (GUID) and
|
|
Serial Attach SCSI IDs (SAS) of the blade server and its expansion
|
|
cards (daughter cards).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeHardwareVpd 7 }
|
|
|
|
bladeAndExpCardWwnGuidVpdEntry OBJECT-TYPE
|
|
SYNTAX BladeAndExpCardWwnGuidVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade WWN/GUID entries.
|
|
For consistent results, view as a table and not as individual entries."
|
|
INDEX { bladeAndExpCardWwnGuidVpdIndex }
|
|
::= { bladeAndExpCardWwnGuidVpdTable 1 }
|
|
|
|
BladeAndExpCardWwnGuidVpdEntry ::= SEQUENCE {
|
|
bladeAndExpCardWwnGuidVpdIndex INTEGER,
|
|
bladeAndExpCardWwnGuidVpdBayNumber OCTET STRING,
|
|
bladeAndExpCardWwnGuidVpdName OCTET STRING,
|
|
bladeAndExpCardWwnGuidVpdBladeBayNumber OCTET STRING,
|
|
bladeAndExpCardWwnGuidVpdType INTEGER,
|
|
bladeAndExpCardWwnGuidVpd1 OCTET STRING,
|
|
bladeAndExpCardWwnGuidVpd2 OCTET STRING,
|
|
bladeAndExpCardWwnGuidVpd3 OCTET STRING,
|
|
bladeAndExpCardWwnGuidVpd4 OCTET STRING,
|
|
bladeAndExpCardWwnGuidVpd5 OCTET STRING,
|
|
bladeAndExpCardWwnGuidVpd6 OCTET STRING,
|
|
bladeAndExpCardWwnGuidVpd7 OCTET STRING,
|
|
bladeAndExpCardWwnGuidVpd8 OCTET STRING
|
|
}
|
|
|
|
bladeAndExpCardWwnGuidVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade or expansion card index.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeAndExpCardWwnGuidVpdEntry 1 }
|
|
|
|
bladeAndExpCardWwnGuidVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade or expansion card VPD bay number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeAndExpCardWwnGuidVpdEntry 2 }
|
|
|
|
bladeAndExpCardWwnGuidVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade or expansion card.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeAndExpCardWwnGuidVpdEntry 3 }
|
|
|
|
bladeAndExpCardWwnGuidVpdBladeBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For expansion cards, it's the blade bay number of the blade
|
|
expansion card. For blades, it's the bay number of the blade.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeAndExpCardWwnGuidVpdEntry 4 }
|
|
|
|
bladeAndExpCardWwnGuidVpdType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvailable(0),
|
|
wwn(1),
|
|
guid(2),
|
|
sas(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade or expansion card WWN/GUID/SAS Type.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeAndExpCardWwnGuidVpdEntry 5 }
|
|
|
|
bladeAndExpCardWwnGuidVpd1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade or expansion card WWN/GUID 1.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeAndExpCardWwnGuidVpdEntry 6 }
|
|
|
|
bladeAndExpCardWwnGuidVpd2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade or expansion card WWN/GUID 2.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeAndExpCardWwnGuidVpdEntry 7 }
|
|
|
|
bladeAndExpCardWwnGuidVpd3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade or expansion card WWN/GUID 3.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeAndExpCardWwnGuidVpdEntry 8 }
|
|
|
|
bladeAndExpCardWwnGuidVpd4 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade or expansion card WWN/GUID 4.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeAndExpCardWwnGuidVpdEntry 9 }
|
|
|
|
bladeAndExpCardWwnGuidVpd5 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade or expansion card WWN/GUID 5.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeAndExpCardWwnGuidVpdEntry 10 }
|
|
|
|
bladeAndExpCardWwnGuidVpd6 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade or expansion card WWN/GUID 6.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeAndExpCardWwnGuidVpdEntry 11 }
|
|
|
|
bladeAndExpCardWwnGuidVpd7 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade or expansion card WWN/GUID 7.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeAndExpCardWwnGuidVpdEntry 12 }
|
|
|
|
bladeAndExpCardWwnGuidVpd8 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade or expansion card WWN/GUID 8.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeAndExpCardWwnGuidVpdEntry 13 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Blade managerment card vpd
|
|
-- ********************************************************************************
|
|
|
|
bladeManagementCardVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeManagementCardVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of VPD information for the blade
|
|
management card component.
|
|
For consistent results, view as a table
|
|
and not as individual entries."
|
|
::= { bladeHardwareVpd 8 }
|
|
|
|
bladeManagementCardVpdEntry OBJECT-TYPE
|
|
SYNTAX BladeManagementCardVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management card VPD entry.
|
|
For consistent results, view as a table
|
|
and not as individual entries."
|
|
INDEX { bladeManagementCardVpdIndex }
|
|
::= { bladeManagementCardVpdTable 1 }
|
|
|
|
BladeManagementCardVpdEntry ::= SEQUENCE {
|
|
bladeManagementCardVpdIndex INTEGER,
|
|
bladeManagementCardVpdBayNumber OCTET STRING,
|
|
bladeManagementCardVpdManufacturingId OCTET STRING,
|
|
bladeManagementCardVpdFruNumber OCTET STRING,
|
|
bladeManagementCardVpdHardwareRevision INTEGER,
|
|
bladeManagementCardVpdSerialNumber OCTET STRING,
|
|
bladeManagementCardVpdMachineType OCTET STRING,
|
|
bladeManagementCardVpdUuid OCTET STRING,
|
|
bladeManagementCardVpdManufDate OCTET STRING,
|
|
bladeManagementCardVpdPartNumber OCTET STRING,
|
|
bladeManagementCardVpdFruSerial OCTET STRING,
|
|
bladeManagementCardVpdMachineModel OCTET STRING,
|
|
bladeManagementCardVpdManufacturingIDNumber OCTET STRING,
|
|
bladeManagementCardVpdProductId OCTET STRING,
|
|
bladeManagementCardVpdSubManufacturerId OCTET STRING,
|
|
bladeManagementCardVpdClei OCTET STRING,
|
|
bladeManagementCardVpdHardwareRevisionString OCTET STRING
|
|
}
|
|
|
|
bladeManagementCardVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management card VPD index.
|
|
For consistent results, view as a table
|
|
and not as individual entries."
|
|
::= { bladeManagementCardVpdEntry 1 }
|
|
|
|
bladeManagementCardVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management card VPD Bay number.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
::= { bladeManagementCardVpdEntry 2 }
|
|
|
|
bladeManagementCardVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management card VPD manufacturing ID.
|
|
For consistent results, view as a table and not as
|
|
individual entries."
|
|
::= { bladeManagementCardVpdEntry 3 }
|
|
bladeManagementCardVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management card VPD FRU number.
|
|
For consistent results, view as a table and not
|
|
as individual entries."
|
|
::= { bladeManagementCardVpdEntry 4 }
|
|
|
|
|
|
bladeManagementCardVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management card VPD hardware revision.
|
|
For consistent results, view as a table and not as
|
|
individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { bladeManagementCardVpdEntry 5 }
|
|
|
|
bladeManagementCardVpdSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management card VPD serial number.
|
|
For consistent results, view as a table and not
|
|
as individual entries."
|
|
::= { bladeManagementCardVpdEntry 6 }
|
|
|
|
bladeManagementCardVpdMachineType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management card VPD machine type.
|
|
For consistent results, view as a table and not
|
|
as individual entries."
|
|
::= { bladeManagementCardVpdEntry 7 }
|
|
|
|
bladeManagementCardVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management card VPD UUID.
|
|
For consistent results, view as a table
|
|
and not as individual entries."
|
|
::= { bladeManagementCardVpdEntry 8 }
|
|
bladeManagementCardVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management card VPD Manufacture Date.
|
|
For consistent results, view as a table and not as
|
|
individual entries."
|
|
::= { bladeManagementCardVpdEntry 9 }
|
|
bladeManagementCardVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management card VPD Part number.
|
|
For consistent results, view as a table and not
|
|
as individual entries."
|
|
::= { bladeManagementCardVpdEntry 10 }
|
|
|
|
bladeManagementCardVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management card VPD FRU serial number.
|
|
For consistent results, view as a table and not as
|
|
individual entries."
|
|
::= { bladeManagementCardVpdEntry 11 }
|
|
|
|
bladeManagementCardVpdMachineModel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management card VPD machine model.
|
|
For consistent results, view as a table and not
|
|
as individual entries."
|
|
::= { bladeManagementCardVpdEntry 12 }
|
|
|
|
bladeManagementCardVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management card VPD manufacturer ID.
|
|
For consistent results, view as a table and not as
|
|
individual entries."
|
|
::= { bladeManagementCardVpdEntry 13 }
|
|
|
|
bladeManagementCardVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management card VPD Product ID.
|
|
For consistent results, view as a table and not
|
|
as individual entries."
|
|
::= { bladeManagementCardVpdEntry 14 }
|
|
|
|
bladeManagementCardVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management card VPD subsystem manufacturer ID.
|
|
For consistent results, view as a table and not as
|
|
individual entries."
|
|
::= { bladeManagementCardVpdEntry 15 }
|
|
|
|
bladeManagementCardVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management card VPD Common Language Equipment
|
|
Identifier (CLEI).
|
|
For consistent results, view as a table and not as
|
|
individual entries."
|
|
::= { bladeManagementCardVpdEntry 16 }
|
|
|
|
bladeManagementCardVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management card VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as
|
|
individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { bladeManagementCardVpdEntry 17 }
|
|
|
|
-- ********************************************************************************
|
|
-- System Firmware Level VPD
|
|
-- ********************************************************************************
|
|
bladeFirmwareVpd OBJECT IDENTIFIER ::= { vpdInformation 5 }
|
|
|
|
|
|
bladeBiosVPDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeBiosVPDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade firmware vital product data (VPD) information."
|
|
::= { bladeFirmwareVpd 1 }
|
|
|
|
bladeBiosVPDEntry OBJECT-TYPE
|
|
SYNTAX BladeBiosVPDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade firmware VPD table entry"
|
|
INDEX { bladeBiosVpdIndex }
|
|
::= { bladeBiosVPDTable 1 }
|
|
|
|
|
|
BladeBiosVPDEntry ::= SEQUENCE {
|
|
bladeBiosVpdIndex INTEGER,
|
|
bladeBiosVpdId INTEGER,
|
|
bladeBiosVpdExists INTEGER,
|
|
bladeBiosVpdPowerState INTEGER,
|
|
bladeBiosVpdName OCTET STRING,
|
|
bladeBiosVpdBuildId OCTET STRING,
|
|
bladeBiosVpdRevision OCTET STRING,
|
|
bladeBiosVpdDate OCTET STRING,
|
|
bladeBiosVpdLevelStatus OCTET STRING
|
|
}
|
|
|
|
bladeBiosVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade firmware VPD table index."
|
|
::= { bladeBiosVPDEntry 1 }
|
|
|
|
|
|
bladeBiosVpdId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeBiosVPDEntry 2 }
|
|
|
|
bladeBiosVpdExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeBiosVPDEntry 3 }
|
|
|
|
bladeBiosVpdPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
standby(3),
|
|
hibernate(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the power state of the blade specified."
|
|
::= { bladeBiosVPDEntry 4 }
|
|
|
|
bladeBiosVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeBiosVPDEntry 5 }
|
|
|
|
bladeBiosVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The build ID for the blade firmware."
|
|
::= { bladeBiosVPDEntry 6 }
|
|
|
|
bladeBiosVpdRevision OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The revision of the blade firmware."
|
|
::= { bladeBiosVPDEntry 7 }
|
|
|
|
bladeBiosVpdDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date of the blade firmware."
|
|
::= { bladeBiosVPDEntry 8 }
|
|
|
|
bladeBiosVpdLevelStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The level status of the blade bios firmware build ID.
|
|
It has three possible values as Different (mismatch firmware build ID), Match (the
|
|
same firmware build ID), Unique (only one such firmware build ID)."
|
|
::= { bladeBiosVPDEntry 9 }
|
|
|
|
|
|
bladeDiagsVPDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeDiagsVPDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade firmware vital product data (VPD) information."
|
|
::= { bladeFirmwareVpd 2 }
|
|
|
|
bladeDiagsVPDEntry OBJECT-TYPE
|
|
SYNTAX BladeDiagsVPDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade firmware VPD table entry"
|
|
INDEX { bladeDiagsVpdIndex }
|
|
::= { bladeDiagsVPDTable 1 }
|
|
|
|
|
|
BladeDiagsVPDEntry ::= SEQUENCE {
|
|
bladeDiagsVpdIndex INTEGER,
|
|
bladeDiagsVpdId INTEGER,
|
|
bladeDiagsVpdExists INTEGER,
|
|
bladeDiagsVpdPowerState INTEGER,
|
|
bladeDiagsVpdName OCTET STRING,
|
|
bladeDiagsVpdBuildId OCTET STRING,
|
|
bladeDiagsVpdRevision OCTET STRING,
|
|
bladeDiagsVpdDate OCTET STRING,
|
|
bladeDiagsVpdLevelStatus OCTET STRING
|
|
}
|
|
|
|
bladeDiagsVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade firmware VPD table index."
|
|
::= { bladeDiagsVPDEntry 1 }
|
|
|
|
|
|
bladeDiagsVpdId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeDiagsVPDEntry 2 }
|
|
|
|
bladeDiagsVpdExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeDiagsVPDEntry 3 }
|
|
|
|
bladeDiagsVpdPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
standby(3),
|
|
hibernate(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the power state of the blade specified."
|
|
::= { bladeDiagsVPDEntry 4 }
|
|
|
|
bladeDiagsVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeDiagsVPDEntry 5 }
|
|
|
|
bladeDiagsVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The build ID for the blade firmware."
|
|
::= { bladeDiagsVPDEntry 6 }
|
|
|
|
bladeDiagsVpdRevision OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The revision of the blade firmware."
|
|
::= { bladeDiagsVPDEntry 7 }
|
|
|
|
bladeDiagsVpdDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date of the blade firmware."
|
|
::= { bladeDiagsVPDEntry 8 }
|
|
|
|
bladeDiagsVpdLevelStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The level status of the blade diagnostics firmware build ID.
|
|
It has three possible values as Different (mismatch firmware build ID), Match (the
|
|
same firmware build ID), Unique (only one such firmware build ID)."
|
|
::= { bladeDiagsVPDEntry 9 }
|
|
|
|
bladeSysMgmtProcVPDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeSysMgmtProcVPDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade firmware vital product data (VPD) information."
|
|
::= { bladeFirmwareVpd 3 }
|
|
|
|
bladeSysMgmtProcVPDEntry OBJECT-TYPE
|
|
SYNTAX BladeSysMgmtProcVPDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade firmware VPD table entry"
|
|
INDEX { bladeSysMgmtProcVpdIndex }
|
|
::= { bladeSysMgmtProcVPDTable 1 }
|
|
|
|
|
|
BladeSysMgmtProcVPDEntry ::= SEQUENCE {
|
|
bladeSysMgmtProcVpdIndex INTEGER,
|
|
bladeSysMgmtProcVpdId INTEGER,
|
|
bladeSysMgmtProcVpdExists INTEGER,
|
|
bladeSysMgmtProcVpdPowerState INTEGER,
|
|
bladeSysMgmtProcVpdName OCTET STRING,
|
|
bladeSysMgmtProcVpdBuildId OCTET STRING,
|
|
bladeSysMgmtProcVpdRevision OCTET STRING,
|
|
bladeSysMgmtProcVpdLevelStatus OCTET STRING
|
|
}
|
|
|
|
bladeSysMgmtProcVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade firmware VPD table index."
|
|
::= { bladeSysMgmtProcVPDEntry 1 }
|
|
|
|
|
|
bladeSysMgmtProcVpdId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeSysMgmtProcVPDEntry 2 }
|
|
|
|
bladeSysMgmtProcVpdExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeSysMgmtProcVPDEntry 3 }
|
|
|
|
bladeSysMgmtProcVpdPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
standby(3),
|
|
hibernate(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the power state of the blade specified."
|
|
::= { bladeSysMgmtProcVPDEntry 4 }
|
|
|
|
bladeSysMgmtProcVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeSysMgmtProcVPDEntry 5 }
|
|
|
|
bladeSysMgmtProcVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The build ID for the blade firmware."
|
|
::= { bladeSysMgmtProcVPDEntry 6 }
|
|
|
|
bladeSysMgmtProcVpdRevision OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The revision of the blade firmware."
|
|
::= { bladeSysMgmtProcVPDEntry 7 }
|
|
|
|
bladeSysMgmtProcVpdLevelStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The level status of the blade system management processor firmware build ID.
|
|
It has three possible values as Different (mismatch firmware build ID), Match (the
|
|
same firmware build ID), Unique (only one such firmware build ID)."
|
|
::= { bladeSysMgmtProcVPDEntry 8 }
|
|
|
|
bladecKVMVPDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladecKVMVPDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade firmware vital product data (VPD) information."
|
|
::= { bladeFirmwareVpd 4 }
|
|
|
|
bladecKVMVPDEntry OBJECT-TYPE
|
|
SYNTAX BladecKVMVPDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade firmware VPD table entry"
|
|
INDEX { bladecKVMVpdIndex }
|
|
::= { bladecKVMVPDTable 1 }
|
|
|
|
|
|
BladecKVMVPDEntry ::= SEQUENCE {
|
|
bladecKVMVpdIndex INTEGER,
|
|
bladecKVMVpdId INTEGER,
|
|
bladecKVMVpdExists INTEGER,
|
|
bladecKVMVpdPowerState INTEGER,
|
|
bladecKVMVpdName OCTET STRING,
|
|
bladecKVMVpdRevision OCTET STRING
|
|
}
|
|
|
|
bladecKVMVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade firmware VPD table index."
|
|
::= { bladecKVMVPDEntry 1 }
|
|
|
|
|
|
bladecKVMVpdId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladecKVMVPDEntry 2 }
|
|
|
|
bladecKVMVpdExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade specified exists or not."
|
|
::= { bladecKVMVPDEntry 3 }
|
|
|
|
bladecKVMVpdPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
standby(3),
|
|
hibernate(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the power state of the blade specified."
|
|
::= { bladecKVMVPDEntry 4 }
|
|
|
|
bladecKVMVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladecKVMVPDEntry 5 }
|
|
|
|
bladecKVMVpdRevision OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The revision of the blade firmware."
|
|
::= { bladecKVMVPDEntry 7 }
|
|
|
|
-- ********************************************************************************
|
|
-- Blade Firmware Build ID
|
|
-- ********************************************************************************
|
|
|
|
bladeFWBuildIDs OBJECT IDENTIFIER ::= { bladeFirmwareVpd 5}
|
|
|
|
|
|
bladeFWBuildIDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeFWBuildIDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Blade Firmware Build ID entries information."
|
|
::= { bladeFWBuildIDs 1 }
|
|
|
|
bladeFWBuildIDEntry OBJECT-TYPE
|
|
SYNTAX BladeFWBuildIDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Firmware Build ID table entry"
|
|
INDEX { bladeFWBuildIDIndex }
|
|
::= { bladeFWBuildIDTable 1 }
|
|
|
|
|
|
BladeFWBuildIDEntry ::= SEQUENCE {
|
|
bladeFWBuildIDIndex INTEGER,
|
|
bladeFWBuildMfg OCTET STRING,
|
|
bladeFWBuildMT OCTET STRING,
|
|
bladeFWBuildFWType OCTET STRING,
|
|
bladeFWBuildID OCTET STRING,
|
|
bladeFWBuildRev OCTET STRING
|
|
}
|
|
|
|
|
|
bladeFWBuildIDIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index number of one Build ID entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeFWBuildIDEntry 1 }
|
|
|
|
bladeFWBuildMfg OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Manufacturer property of one Build ID entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeFWBuildIDEntry 2 }
|
|
|
|
bladeFWBuildMT OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Machine Type property of one Build ID entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeFWBuildIDEntry 3 }
|
|
|
|
bladeFWBuildFWType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Firmware Type property of one Build ID entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeFWBuildIDEntry 4 }
|
|
|
|
bladeFWBuildID OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Build ID property of one Build ID entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeFWBuildIDEntry 5 }
|
|
|
|
bladeFWBuildRev OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Build Revision property of one Build ID entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bladeFWBuildIDEntry 6 }
|
|
|
|
|
|
createBladeFWBuildIDs OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Create one new Build ID List from current installed blades.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { bladeFWBuildIDs 2}
|
|
|
|
addBladeFWBuildID OBJECT IDENTIFIER ::= { bladeFWBuildIDs 3}
|
|
|
|
addBladeMfg OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Add one Build ID entry into the Build ID List.
|
|
This is to set Manufacturer property."
|
|
::= { addBladeFWBuildID 1}
|
|
|
|
addBladeMt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Add one Build ID entry into the Build ID List.
|
|
This is to set Machine Type property."
|
|
::= {addBladeFWBuildID 2}
|
|
|
|
addBladeFt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Add one Build ID entry into the Build ID List.
|
|
This is to set Firmware Type property."
|
|
::= { addBladeFWBuildID 3}
|
|
|
|
addBladeBuildID OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Add one Build ID entry into the Build ID List.
|
|
This is to set Build ID property."
|
|
::= { addBladeFWBuildID 4}
|
|
|
|
addBladeBuildRev OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Add one Build ID entry into the Build ID List.
|
|
This is to set Build Revision property."
|
|
::= { addBladeFWBuildID 5}
|
|
|
|
exeBladeAdding OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Add one Build ID entry into the Build ID List.
|
|
This is to perform the adding action.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { addBladeFWBuildID 6}
|
|
|
|
rmBladeFWBuildID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remove one Build ID entry from the Build ID List.
|
|
The index of the Build ID entry in the list is required.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { bladeFWBuildIDs 4}
|
|
|
|
rmAllBladeFWBuildIDs OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remove all Build ID entries from the Build ID List.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { bladeFWBuildIDs 5}
|
|
|
|
buildIDFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..254))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"File name of the Build ID list that will be used in import function."
|
|
::= { bladeFWBuildIDs 6 }
|
|
|
|
buildIDURIName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..254))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the fully qualified remote location of the build ID list. Use
|
|
buildIDFileName to specify the filename. A fully qualified remote location
|
|
contains a supported protocol followed by a colon and two slashes (//),
|
|
userid and password separated by a colon for login authentication, an
|
|
@ sign, followed by the hostname or IP address of the server where the
|
|
build ID list resides, followed by an optional port number to the hostname,
|
|
and the full pathname to the file. Note that if the port number is specified,
|
|
it must be separated with the hostname (or IP address) by a colon.
|
|
|
|
The AMM currently supports the following protocols:
|
|
TFTP, FTP, FTPS, HTTP and HTTPS.
|
|
|
|
The complete format of a fully qualified remote location is:
|
|
|
|
<protocol>://<userid:password>@<hostname:port>/<pathname>
|
|
|
|
An example of a fully qualified remote location can be:
|
|
ftp://USERID:PASSW0RD@192.168.0.2:30045/tmp
|
|
where the ftp protocol will be used for transferring the file in
|
|
this location, username is USERID, password is PASSW0RD, host IP address
|
|
is 192.168.0.2, port number is 30045, and the full pathname for the build ID
|
|
list is /tmp.
|
|
|
|
Some protocols do not need the username, password, and the port number, so the
|
|
minimum requirement for a fully qualified location can be:
|
|
<protocol>://<hostname>/<pathname>."
|
|
::= { bladeFWBuildIDs 7 }
|
|
|
|
buildIDtftpIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If importing/exporting via the legacy method using a tftp server, then
|
|
set the IP address or host name of the TFTP server where
|
|
the firmware file resides. The address must be entered in a
|
|
dotted decimal IP string (e.g. 9.37.44.2)."
|
|
::= { bladeFWBuildIDs 8 }
|
|
|
|
importBladeFWBuildIDs OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Import one Build ID List set by the buildIDFilename from a specific location
|
|
set by buildIDServer."
|
|
::= { bladeFWBuildIDs 9}
|
|
|
|
exportBladeFWBuildIDs OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Export the current Build ID List from the active AMM to a specific location
|
|
set by buildIDServer.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { bladeFWBuildIDs 10}
|
|
|
|
statusBladeFWBuildIDs OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gives the status message from the last import or export operation."
|
|
::= { bladeFWBuildIDs 11}
|
|
|
|
-- ********************************************************************************
|
|
-- Switch Module Hardware VPD
|
|
-- ********************************************************************************
|
|
smHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 6 }
|
|
|
|
smHardwareVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the switch module hardware components.
|
|
For consistent results, view as a table and not as
|
|
individual entries."
|
|
::= { smHardwareVpd 1 }
|
|
|
|
smHardwareVpdEntry OBJECT-TYPE
|
|
SYNTAX SmHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD entry.
|
|
For consistent results, view as a table and
|
|
not as individual entries."
|
|
INDEX { smHardwareVpdIndex }
|
|
::= { smHardwareVpdTable 1 }
|
|
|
|
SmHardwareVpdEntry ::= SEQUENCE {
|
|
smHardwareVpdIndex INTEGER,
|
|
smHardwareVpdBayNumber OCTET STRING,
|
|
smHardwareVpdManufacturingId OCTET STRING,
|
|
smHardwareVpdFruNumber OCTET STRING,
|
|
smHardwareVpdHardwareRevision INTEGER,
|
|
smHardwareVpdUuid OCTET STRING,
|
|
smHardwareVpdManufDate OCTET STRING,
|
|
smHardwareVpdPartNumber OCTET STRING,
|
|
smHardwareVpdFruSerial OCTET STRING,
|
|
smHardwareVpdManufacturingIDNumber OCTET STRING,
|
|
smHardwareVpdProductId OCTET STRING,
|
|
smHardwareVpdSubManufacturerId OCTET STRING,
|
|
smHardwareVpdClei OCTET STRING,
|
|
smHardwareVpdWwnGuid OCTET STRING,
|
|
smHardwareVpdWwnGuidType OCTET STRING,
|
|
smHardwareVpdWidth INTEGER,
|
|
smHardwareVpdHardwareRevisionString OCTET STRING
|
|
}
|
|
|
|
smHardwareVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD index.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { smHardwareVpdEntry 1 }
|
|
|
|
smHardwareVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD Bay number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { smHardwareVpdEntry 2 }
|
|
|
|
smHardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { smHardwareVpdEntry 3 }
|
|
|
|
smHardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { smHardwareVpdEntry 4 }
|
|
|
|
|
|
smHardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { smHardwareVpdEntry 5 }
|
|
|
|
smHardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD UUID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { smHardwareVpdEntry 8 }
|
|
|
|
smHardwareVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD manufacture date.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { smHardwareVpdEntry 9 }
|
|
|
|
smHardwareVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD Part Number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { smHardwareVpdEntry 10 }
|
|
|
|
smHardwareVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD FRU Serial.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { smHardwareVpdEntry 11 }
|
|
|
|
smHardwareVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { smHardwareVpdEntry 12 }
|
|
|
|
smHardwareVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD product ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { smHardwareVpdEntry 13 }
|
|
|
|
smHardwareVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD subsystem manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { smHardwareVpdEntry 14 }
|
|
|
|
smHardwareVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD Common Language Equipment Identifier (CLEI).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { smHardwareVpdEntry 15 }
|
|
|
|
smHardwareVpdWwnGuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD World Wide Name or Global Unique ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { smHardwareVpdEntry 16 }
|
|
|
|
smHardwareVpdWwnGuidType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The WWN/GUID/SAS entry is actually World Wide Name, Global Unique ID
|
|
or Serial Attach SCSI ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { smHardwareVpdEntry 17 }
|
|
|
|
smHardwareVpdWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The width of the switch module hardware.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { smHardwareVpdEntry 18 }
|
|
|
|
smHardwareVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { smHardwareVpdEntry 20 }
|
|
|
|
-- ********************************************************************************
|
|
-- Switch Interposer Hardware VPD
|
|
-- ********************************************************************************
|
|
|
|
smInpHardwareVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmInpHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the switch interposer hardware components.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only."
|
|
::= { smHardwareVpd 2 }
|
|
|
|
smInpHardwareVpdEntry OBJECT-TYPE
|
|
SYNTAX SmInpHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Interposer hardware VPD entry.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only."
|
|
INDEX { smInpHardwareVpdIndex }
|
|
::= { smInpHardwareVpdTable 1 }
|
|
|
|
SmInpHardwareVpdEntry ::= SEQUENCE {
|
|
smInpHardwareVpdIndex INTEGER,
|
|
smInpHardwareVpdBayNumber OCTET STRING,
|
|
smInpHardwareVpdManufacturingId OCTET STRING,
|
|
smInpHardwareVpdFruNumber OCTET STRING,
|
|
smInpHardwareVpdHardwareRevision INTEGER,
|
|
smInpHardwareVpdUuid OCTET STRING,
|
|
smInpHardwareVpdManufDate OCTET STRING,
|
|
smInpHardwareVpdPartNumber OCTET STRING,
|
|
smInpHardwareVpdFruSerial OCTET STRING,
|
|
smInpHardwareVpdManufacturingIDNumber OCTET STRING,
|
|
smInpHardwareVpdProductId OCTET STRING,
|
|
smInpHardwareVpdSubManufacturerId OCTET STRING,
|
|
smInpHardwareVpdClei OCTET STRING,
|
|
smInpHardwareVpdWwnGuid OCTET STRING,
|
|
smInpHardwareVpdWwnGuidType OCTET STRING,
|
|
smInpHardwareVpdWidth INTEGER,
|
|
smInpHardwareVpdName OCTET STRING,
|
|
smInpHardwareVpdHardwareRevisionString OCTET STRING
|
|
}
|
|
|
|
smInpHardwareVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Interposer hardware VPD index.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only."
|
|
::= { smInpHardwareVpdEntry 1 }
|
|
|
|
smInpHardwareVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Interposer hardware VPD Bay number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only."
|
|
::= { smInpHardwareVpdEntry 2 }
|
|
|
|
smInpHardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Interposer hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only."
|
|
::= { smInpHardwareVpdEntry 3 }
|
|
|
|
smInpHardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Interposer hardware VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only."
|
|
::= { smInpHardwareVpdEntry 4 }
|
|
|
|
|
|
smInpHardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Interposer hardware VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only.
|
|
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { smInpHardwareVpdEntry 5 }
|
|
|
|
smInpHardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Interposer hardware VPD UUID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only."
|
|
::= { smInpHardwareVpdEntry 8 }
|
|
|
|
smInpHardwareVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Interposer hardware VPD manufacture Date.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only."
|
|
::= { smInpHardwareVpdEntry 9 }
|
|
|
|
smInpHardwareVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Interposer hardware VPD Part Number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only."
|
|
::= { smInpHardwareVpdEntry 10 }
|
|
|
|
smInpHardwareVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Interposer module hardware VPD FRU Serial.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only."
|
|
::= { smInpHardwareVpdEntry 11 }
|
|
|
|
smInpHardwareVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Interposer module hardware VPD manufacturer ID Number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only."
|
|
::= { smInpHardwareVpdEntry 12 }
|
|
|
|
smInpHardwareVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Interposer module hardware VPD product ID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only."
|
|
::= { smInpHardwareVpdEntry 13 }
|
|
|
|
smInpHardwareVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Interposer module hardware VPD subsystem manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only."
|
|
::= { smInpHardwareVpdEntry 14 }
|
|
|
|
smInpHardwareVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Interposer module hardware VPD Common Language Equipment Identifier (CLEI).
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only."
|
|
::= { smInpHardwareVpdEntry 15 }
|
|
|
|
smInpHardwareVpdWwnGuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Interposer module hardware VPD World Wide Name or Global Unique ID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only."
|
|
::= { smInpHardwareVpdEntry 16 }
|
|
|
|
smInpHardwareVpdWwnGuidType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Switch Interposer WWN/GUID/SAS entry is actually World Wide
|
|
Name, Global Unique ID or Serial Attach SCSI ID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only."
|
|
::= { smInpHardwareVpdEntry 17 }
|
|
|
|
smInpHardwareVpdWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The width of the switch Interposer module hardware.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { smInpHardwareVpdEntry 18 }
|
|
|
|
smInpHardwareVpdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Switch Interposer Name.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only."
|
|
::= { smInpHardwareVpdEntry 19 }
|
|
|
|
smInpHardwareVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Interposer hardware VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HS only.
|
|
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { smInpHardwareVpdEntry 20 }
|
|
|
|
-- ********************************************************************************
|
|
-- Switch module Information
|
|
-- ********************************************************************************
|
|
|
|
smFirmwareVpd OBJECT IDENTIFIER ::= { vpdInformation 7 }
|
|
-- Server blade switch module information
|
|
|
|
smMainAppVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmMainAppVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module main application VPD information table."
|
|
::= {smFirmwareVpd 1}
|
|
|
|
smMainAppVpdEntry OBJECT-TYPE
|
|
SYNTAX SmMainAppVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module main application VPD table entry"
|
|
INDEX { smMainAppVpdIndex }
|
|
::= { smMainAppVpdTable 1 }
|
|
|
|
SmMainAppVpdEntry ::= SEQUENCE {
|
|
smMainAppVpdIndex INTEGER,
|
|
smMainAppVpdId INTEGER,
|
|
smMainAppVpdExists INTEGER,
|
|
smMainAppVpdSwitchType INTEGER,
|
|
smMainApp1VpdBuildId OCTET STRING,
|
|
smMainApp1VpdBuildDate OCTET STRING,
|
|
smMainApp1VpdRevisionNumber OCTET STRING,
|
|
smMainApp2VpdBuildId OCTET STRING,
|
|
smMainApp2VpdBuildDate OCTET STRING,
|
|
smMainApp2VpdRevisionNumber OCTET STRING,
|
|
smMainApp3VpdBuildId OCTET STRING,
|
|
smMainApp3VpdBuildDate OCTET STRING,
|
|
smMainApp3VpdRevisionNumber OCTET STRING,
|
|
smMainAppVpdSwitchSubType INTEGER
|
|
}
|
|
|
|
smMainAppVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module main application VPD entry index."
|
|
::= { smMainAppVpdEntry 1 }
|
|
|
|
smMainAppVpdId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module numeric identifier."
|
|
::= { smMainAppVpdEntry 2 }
|
|
|
|
smMainAppVpdExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module specified exists or not."
|
|
::= { smMainAppVpdEntry 3 }
|
|
|
|
smMainAppVpdSwitchType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
ethernet(1),
|
|
fibre(2),
|
|
opm(3),
|
|
serialCM(4),
|
|
copperPassThrough(5),
|
|
infiniband(6),
|
|
highSpeed(20),
|
|
passThrough(30),
|
|
sas(40)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the type of switch module installed."
|
|
::= { smMainAppVpdEntry 4 }
|
|
|
|
smMainApp1VpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module firmware build id."
|
|
::= { smMainAppVpdEntry 5 }
|
|
|
|
smMainApp1VpdBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module firmware build date."
|
|
::= { smMainAppVpdEntry 6 }
|
|
|
|
smMainApp1VpdRevisionNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module firmware revision number."
|
|
::= { smMainAppVpdEntry 7 }
|
|
|
|
smMainApp2VpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module firmware build id."
|
|
::= { smMainAppVpdEntry 8 }
|
|
|
|
smMainApp2VpdBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module firmware build date."
|
|
::= { smMainAppVpdEntry 9 }
|
|
|
|
smMainApp2VpdRevisionNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module firmware revision number."
|
|
::= { smMainAppVpdEntry 10 }
|
|
smMainApp3VpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"I/O Module firmware build id."
|
|
::= { smMainAppVpdEntry 11 }
|
|
|
|
smMainApp3VpdBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"I/O Module firmware build date."
|
|
::= { smMainAppVpdEntry 12 }
|
|
|
|
smMainApp3VpdRevisionNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"I/O Module firmware revision number."
|
|
::= { smMainAppVpdEntry 13 }
|
|
|
|
smMainAppVpdSwitchSubType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
ethernet(1),
|
|
fibre(2),
|
|
infiniband(6),
|
|
sas(7),
|
|
raidsas(8),
|
|
icpm(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the subtype of switch module installed."
|
|
::= { smMainAppVpdEntry 20 }
|
|
|
|
|
|
|
|
smBootRomVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmBootRomVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module boot ROM VPD information table."
|
|
::= {smFirmwareVpd 2}
|
|
|
|
smBootRomVpdEntry OBJECT-TYPE
|
|
SYNTAX SmBootRomVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module boot ROM VPD table entry"
|
|
INDEX { smBootRomVpdIndex }
|
|
::= { smBootRomVpdTable 1 }
|
|
|
|
SmBootRomVpdEntry ::= SEQUENCE {
|
|
smBootRomVpdIndex INTEGER,
|
|
smBootRomVpdId INTEGER,
|
|
smBootRomVpdExists INTEGER,
|
|
smBootRomVpdSwitchType INTEGER,
|
|
smBootRomVpdBuildId OCTET STRING,
|
|
smBootRomVpdBuildDate OCTET STRING,
|
|
smBootRomVpdRevisionNumber OCTET STRING,
|
|
smBootRomVpdSwitchSubType INTEGER
|
|
}
|
|
|
|
smBootRomVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module boot ROM VPD entry index."
|
|
::= { smBootRomVpdEntry 1 }
|
|
|
|
smBootRomVpdId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module numeric identifier."
|
|
::= { smBootRomVpdEntry 2 }
|
|
|
|
smBootRomVpdExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module specified exists or not."
|
|
::= { smBootRomVpdEntry 3 }
|
|
|
|
smBootRomVpdSwitchType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
ethernet(1),
|
|
fibre(2),
|
|
opm(3),
|
|
serialCM(4),
|
|
copperPassThrough(5),
|
|
infiniband(6),
|
|
highSpeed(20),
|
|
passThrough(30),
|
|
sas(40)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the type of switch module installed."
|
|
::= { smBootRomVpdEntry 4 }
|
|
|
|
smBootRomVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module firmware build ID."
|
|
::= { smBootRomVpdEntry 5 }
|
|
|
|
smBootRomVpdBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module firmware build date."
|
|
::= { smBootRomVpdEntry 6 }
|
|
|
|
smBootRomVpdRevisionNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module firmware revision number."
|
|
::= { smBootRomVpdEntry 7 }
|
|
|
|
smBootRomVpdSwitchSubType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
ethernet(1),
|
|
fibre(2),
|
|
infiniband(6),
|
|
sas(7),
|
|
raidsas(8),
|
|
icpm(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the subtype of switch module installed."
|
|
::= { smBootRomVpdEntry 8 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Power Module Hardware VPD
|
|
-- ********************************************************************************
|
|
pmHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 8 }
|
|
|
|
pmHardwareVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PmHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the power module hardware components.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { pmHardwareVpd 1 }
|
|
|
|
pmHardwareVpdEntry OBJECT-TYPE
|
|
SYNTAX PmHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
INDEX { pmHardwareVpdIndex }
|
|
::= { pmHardwareVpdTable 1 }
|
|
|
|
PmHardwareVpdEntry ::= SEQUENCE {
|
|
pmHardwareVpdIndex INTEGER,
|
|
pmHardwareVpdBayNumber OCTET STRING,
|
|
pmHardwareVpdManufacturingId OCTET STRING,
|
|
pmHardwareVpdFruNumber OCTET STRING,
|
|
pmHardwareVpdHardwareRevision INTEGER,
|
|
pmHardwareVpdUuid OCTET STRING,
|
|
pmHardwareVpdManufDate OCTET STRING,
|
|
pmHardwareVpdPartNumber OCTET STRING,
|
|
pmHardwareVpdFruSerial OCTET STRING,
|
|
pmHardwareVpdManufacturingIDNumber OCTET STRING,
|
|
pmHardwareVpdProductId OCTET STRING,
|
|
pmHardwareVpdSubManufacturerId OCTET STRING,
|
|
pmHardwareVpdClei OCTET STRING,
|
|
pmHardwareVpdHardwareRevisionString OCTET STRING
|
|
}
|
|
|
|
pmHardwareVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD index.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { pmHardwareVpdEntry 1 }
|
|
|
|
pmHardwareVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD Bay number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { pmHardwareVpdEntry 2 }
|
|
|
|
pmHardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { pmHardwareVpdEntry 3 }
|
|
|
|
pmHardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { pmHardwareVpdEntry 4 }
|
|
|
|
|
|
pmHardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { pmHardwareVpdEntry 5 }
|
|
|
|
pmHardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD UUID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { pmHardwareVpdEntry 8 }
|
|
|
|
pmHardwareVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD Manufacture Date.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { pmHardwareVpdEntry 9 }
|
|
|
|
pmHardwareVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD Part Number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { pmHardwareVpdEntry 10 }
|
|
|
|
pmHardwareVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD FRU Serial.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { pmHardwareVpdEntry 11 }
|
|
|
|
pmHardwareVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { pmHardwareVpdEntry 12 }
|
|
|
|
pmHardwareVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD product ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { pmHardwareVpdEntry 13 }
|
|
|
|
pmHardwareVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD subsystem manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { pmHardwareVpdEntry 14 }
|
|
|
|
pmHardwareVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD Common Language Equipment Identifier (CLEI).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { pmHardwareVpdEntry 15 }
|
|
|
|
pmHardwareVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power module hardware VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { pmHardwareVpdEntry 16 }
|
|
|
|
-- ********************************************************************************
|
|
-- Media Tray Hardware VPD
|
|
-- ********************************************************************************
|
|
mtHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 9 }
|
|
|
|
mtHardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 1 hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mtHardwareVpd 3 }
|
|
|
|
mtHardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 1 hardware VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mtHardwareVpd 4 }
|
|
|
|
|
|
mtHardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 1 hardware VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { mtHardwareVpd 5 }
|
|
|
|
mtHardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 1 hardware VPD UUID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mtHardwareVpd 8 }
|
|
|
|
mtHardwareVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 1 hardware VPD manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mtHardwareVpd 9 }
|
|
|
|
mtHardwareVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 1 hardware VPD product ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mtHardwareVpd 10 }
|
|
|
|
mtHardwareVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 1 hardware VPD subsystem manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mtHardwareVpd 11 }
|
|
|
|
mtHardwareVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 1 hardware VPD Common Language Equipment Identifier (CLEI).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mtHardwareVpd 12 }
|
|
|
|
mtHardwareVpdCF1Capacity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 1 hardware VPD CompactFlash card capacity.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mtHardwareVpd 13 }
|
|
|
|
mtHardwareVpdCF2Capacity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 1 hardware VPD CompactFlash card capacity.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mtHardwareVpd 14 }
|
|
|
|
mtHardwareVpdBBU1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the presence of Battery Backup Unit 1.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { mtHardwareVpd 15 }
|
|
|
|
mtHardwareVpdBBU2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the presence of Battery Backup Unit 2.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { mtHardwareVpd 16 }
|
|
|
|
mtHardwareVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 1 hardware VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { mtHardwareVpd 17 }
|
|
|
|
mtHardwareVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 1 hardware VPD Manufacture Date."
|
|
::= { mtHardwareVpd 18 }
|
|
|
|
mtHardwareVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 1 hardware VPD Part Number."
|
|
::= { mtHardwareVpd 19 }
|
|
|
|
mtHardwareVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 1 hardware VPD FRU Serial."
|
|
::= { mtHardwareVpd 20 }
|
|
-- ********************************************************************************
|
|
-- Bottom Media Tray Hardware VPD
|
|
-- ********************************************************************************
|
|
mt2HardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 10 }
|
|
|
|
mt2HardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 2 hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mt2HardwareVpd 3 }
|
|
|
|
mt2HardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 2 hardware VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mt2HardwareVpd 4 }
|
|
|
|
|
|
mt2HardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 2 hardware VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { mt2HardwareVpd 5 }
|
|
|
|
mt2HardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 2 hardware VPD UUID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mt2HardwareVpd 8 }
|
|
|
|
mt2HardwareVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 2 hardware VPD manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mt2HardwareVpd 9 }
|
|
|
|
mt2HardwareVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 2 hardware VPD product ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mt2HardwareVpd 10 }
|
|
|
|
mt2HardwareVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 2 hardware VPD subsystem manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mt2HardwareVpd 11 }
|
|
|
|
mt2HardwareVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 2 hardware VPD Common Language Equipment Identifier (CLEI).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mt2HardwareVpd 12 }
|
|
|
|
mt2HardwareVpdCF1Capacity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 2 hardware VPD CompactFlash card capacity.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mt2HardwareVpd 13 }
|
|
|
|
mt2HardwareVpdCF2Capacity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 2 hardware VPD CompactFlash card capacity.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mt2HardwareVpd 14 }
|
|
|
|
mt2HardwareVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 2 hardware VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { mt2HardwareVpd 17 }
|
|
|
|
mt2HardwareVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 2 hardware VPD Manufacture Date."
|
|
::= { mt2HardwareVpd 18 }
|
|
|
|
mt2HardwareVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 2 hardware VPD Part Number."
|
|
::= { mt2HardwareVpd 19 }
|
|
|
|
mt2HardwareVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Media tray 2 hardware VPD FRU Serial."
|
|
::= { mt2HardwareVpd 20 }
|
|
-- ********************************************************************************
|
|
-- Blower Firmware Level VPD
|
|
-- ********************************************************************************
|
|
blowerFirmwareVpd OBJECT IDENTIFIER ::= { vpdInformation 12 }
|
|
|
|
blowerControllerVPDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BlowerControllerVPDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blower controller firmware vital product data (VPD) information.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowerFirmwareVpd 1 }
|
|
|
|
blowerControllerVPDEntry OBJECT-TYPE
|
|
SYNTAX BlowerControllerVPDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower controller firmware VPD table entry"
|
|
INDEX { blowerControllerVpdIndex }
|
|
::= { blowerControllerVPDTable 1 }
|
|
|
|
|
|
BlowerControllerVPDEntry ::= SEQUENCE {
|
|
blowerControllerVpdIndex INTEGER,
|
|
blowerControllerVpdId INTEGER,
|
|
blowerControllerVpdExists INTEGER,
|
|
blowerControllerVpdRevision OCTET STRING
|
|
}
|
|
|
|
blowerControllerVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower controller firmware VPD table index."
|
|
::= { blowerControllerVPDEntry 1 }
|
|
|
|
|
|
blowerControllerVpdId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blower1(1),
|
|
blower2(2),
|
|
blower3(3),
|
|
blower4(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blower ID."
|
|
::= { blowerControllerVPDEntry 2 }
|
|
|
|
blowerControllerVpdExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blower specified exists or not."
|
|
::= { blowerControllerVPDEntry 3 }
|
|
|
|
blowerControllerVpdRevision OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The revision of the blower controller firmware."
|
|
::= { blowerControllerVPDEntry 7 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Blower Hardware VPD
|
|
-- ********************************************************************************
|
|
blowerHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 13 }
|
|
|
|
blowerHardwareVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BlowerHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the blower hardware components.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { blowerHardwareVpd 1 }
|
|
|
|
blowerHardwareVpdEntry OBJECT-TYPE
|
|
SYNTAX BlowerHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower hardware VPD entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
INDEX { blowerHardwareVpdIndex }
|
|
::= { blowerHardwareVpdTable 1 }
|
|
|
|
BlowerHardwareVpdEntry ::= SEQUENCE {
|
|
blowerHardwareVpdIndex INTEGER,
|
|
blowerHardwareVpdBayNumber OCTET STRING,
|
|
blowerHardwareVpdManufacturingId OCTET STRING,
|
|
blowerHardwareVpdFruNumber OCTET STRING,
|
|
blowerHardwareVpdHardwareRevision INTEGER,
|
|
blowerHardwareVpdUuid OCTET STRING,
|
|
blowerHardwareVpdManufDate OCTET STRING,
|
|
blowerHardwareVpdPartNumber OCTET STRING,
|
|
blowerHardwareVpdFruSerial OCTET STRING,
|
|
blowerHardwareVpdManufacturingIDNumber OCTET STRING,
|
|
blowerHardwareVpdProductId OCTET STRING,
|
|
blowerHardwareVpdSubManufacturerId OCTET STRING,
|
|
blowerHardwareVpdClei OCTET STRING,
|
|
blowerHardwareVpdHardwareRevisionString OCTET STRING
|
|
}
|
|
|
|
blowerHardwareVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower hardware VPD index.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { blowerHardwareVpdEntry 1 }
|
|
|
|
blowerHardwareVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower hardware VPD Bay number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { blowerHardwareVpdEntry 2 }
|
|
|
|
blowerHardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { blowerHardwareVpdEntry 3 }
|
|
|
|
blowerHardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower hardware VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { blowerHardwareVpdEntry 4 }
|
|
|
|
|
|
blowerHardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower hardware VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { blowerHardwareVpdEntry 5 }
|
|
|
|
blowerHardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower hardware VPD UUID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { blowerHardwareVpdEntry 8 }
|
|
|
|
blowerHardwareVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower hardware VPD manufacture Date.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { blowerHardwareVpdEntry 9 }
|
|
|
|
blowerHardwareVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower hardware VPD Part Number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { blowerHardwareVpdEntry 10 }
|
|
|
|
blowerHardwareVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower hardware VPD FRU serial number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { blowerHardwareVpdEntry 11 }
|
|
|
|
blowerHardwareVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower hardware VPD manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { blowerHardwareVpdEntry 12 }
|
|
|
|
blowerHardwareVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower hardware VPD product ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { blowerHardwareVpdEntry 13 }
|
|
|
|
blowerHardwareVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower hardware VPD subsystem manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { blowerHardwareVpdEntry 14 }
|
|
|
|
blowerHardwareVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower hardware VPD Common Language Equipment Identifier (CLEI).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { blowerHardwareVpdEntry 15 }
|
|
|
|
blowerHardwareVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blower hardware VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as individual entries.
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { blowerHardwareVpdEntry 16 }
|
|
|
|
-- ********************************************************************************
|
|
-- Fan Pack Firmware Level VPD
|
|
-- ********************************************************************************
|
|
fanPackFirmwareVpd OBJECT IDENTIFIER ::= { vpdInformation 14 }
|
|
|
|
fanPackControllerVPDTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FanPackControllerVPDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of fan pack controller firmware vital product data (VPD) information.
|
|
|
|
NOTE: Fan packs are also referred to as Power Module Chassis Cooling Devices."
|
|
::= { fanPackFirmwareVpd 1 }
|
|
|
|
fanPackControllerVPDEntry OBJECT-TYPE
|
|
SYNTAX FanPackControllerVPDEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan Pack controller firmware VPD table entry"
|
|
INDEX { fanPackControllerVpdIndex }
|
|
::= { fanPackControllerVPDTable 1 }
|
|
|
|
FanPackControllerVPDEntry ::= SEQUENCE {
|
|
fanPackControllerVpdIndex INTEGER,
|
|
fanPackControllerVpdId INTEGER,
|
|
fanPackControllerVpdExists INTEGER,
|
|
fanPackControllerVpdRevision OCTET STRING
|
|
}
|
|
|
|
fanPackControllerVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fan Pack controller firmware VPD table index."
|
|
::= { fanPackControllerVPDEntry 1 }
|
|
|
|
fanPackControllerVpdId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fanPack1(1),
|
|
fanPack2(2),
|
|
fanPack3(3),
|
|
fanPack4(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric fan pack ID."
|
|
::= { fanPackControllerVPDEntry 2 }
|
|
|
|
fanPackControllerVpdExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the fan pack specified exists or not."
|
|
::= { fanPackControllerVPDEntry 3 }
|
|
|
|
fanPackControllerVpdRevision OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The revision of the fan pack controller firmware."
|
|
::= { fanPackControllerVPDEntry 7 }
|
|
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Telco Alarm Panel Hardware VPD
|
|
-- ********************************************************************************
|
|
tapHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 15 }
|
|
|
|
tapHardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco Alarm Panel hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { tapHardwareVpd 3 }
|
|
|
|
tapHardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco Alarm Panel hardware VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { tapHardwareVpd 4 }
|
|
|
|
|
|
tapHardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco Alarm Panel hardware VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only.
|
|
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { tapHardwareVpd 5 }
|
|
|
|
tapHardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco Alarm Panel hardware VPD UUID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { tapHardwareVpd 8 }
|
|
|
|
tapHardwareVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco Alarm Panel hardware VPD manufacture Date.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { tapHardwareVpd 9 }
|
|
|
|
tapHardwareVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco Alarm Panel hardware VPD Part Number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { tapHardwareVpd 10 }
|
|
|
|
tapHardwareVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco Alarm Panel hardware VPD FRU Serial.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { tapHardwareVpd 11 }
|
|
|
|
tapHardwareVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco Alarm Panel hardware VPD manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { tapHardwareVpd 12 }
|
|
|
|
tapHardwareVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco Alarm Panel hardware VPD product ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { tapHardwareVpd 13 }
|
|
|
|
tapHardwareVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco Alarm Panel hardware VPD subsystem manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { tapHardwareVpd 14 }
|
|
|
|
tapHardwareVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco Alarm Panel hardware VPD Common Language Equipment Identifier (CLEI).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { tapHardwareVpd 15 }
|
|
|
|
tapHardwareVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco Alarm Panel hardware VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only.
|
|
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { tapHardwareVpd 16 }
|
|
|
|
-- ********************************************************************************
|
|
-- Network Clock Hardware VPD
|
|
-- ********************************************************************************
|
|
ncHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 16 }
|
|
|
|
ncHardwareVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NcHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Table of the Network Clock hardware components.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { ncHardwareVpd 1 }
|
|
|
|
ncHardwareVpdEntry OBJECT-TYPE
|
|
SYNTAX NcHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock hardware VPD entry.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
INDEX { ncHardwareVpdIndex }
|
|
::= { ncHardwareVpdTable 1 }
|
|
|
|
NcHardwareVpdEntry ::= SEQUENCE {
|
|
ncHardwareVpdIndex INTEGER,
|
|
ncHardwareVpdBayNumber OCTET STRING,
|
|
ncHardwareVpdManufacturingId OCTET STRING,
|
|
ncHardwareVpdFruNumber OCTET STRING,
|
|
ncHardwareVpdHardwareRevision INTEGER,
|
|
ncHardwareVpdUuid OCTET STRING,
|
|
ncHardwareVpdManufDate OCTET STRING,
|
|
ncHardwareVpdPartNumber OCTET STRING,
|
|
ncHardwareVpdFruSerial OCTET STRING,
|
|
ncHardwareVpdManufacturingIDNumber OCTET STRING,
|
|
ncHardwareVpdProductId OCTET STRING,
|
|
ncHardwareVpdSubManufacturerId OCTET STRING,
|
|
ncHardwareVpdClei OCTET STRING,
|
|
ncHardwareVpdHardwareRevisionString OCTET STRING
|
|
}
|
|
|
|
ncHardwareVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock hardware VPD index.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { ncHardwareVpdEntry 1 }
|
|
|
|
ncHardwareVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock hardware VPD Bay number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { ncHardwareVpdEntry 2 }
|
|
|
|
ncHardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { ncHardwareVpdEntry 3 }
|
|
|
|
ncHardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock hardware VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { ncHardwareVpdEntry 4 }
|
|
|
|
|
|
ncHardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock hardware VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only.
|
|
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { ncHardwareVpdEntry 5 }
|
|
|
|
ncHardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock hardware VPD UUID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { ncHardwareVpdEntry 8 }
|
|
|
|
ncHardwareVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock hardware VPD manufacture Date.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { ncHardwareVpdEntry 9 }
|
|
|
|
ncHardwareVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock hardware VPD Part Number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { ncHardwareVpdEntry 10 }
|
|
|
|
ncHardwareVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock hardware VPD FRU serial number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { ncHardwareVpdEntry 11 }
|
|
|
|
ncHardwareVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock hardware VPD manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { ncHardwareVpdEntry 12 }
|
|
|
|
ncHardwareVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock hardware VPD product ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { ncHardwareVpdEntry 13 }
|
|
|
|
ncHardwareVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock hardware VPD subsystem manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { ncHardwareVpdEntry 14 }
|
|
|
|
ncHardwareVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock hardware VPD Common Language Equipment Identifier (CLEI).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { ncHardwareVpdEntry 15 }
|
|
|
|
ncHardwareVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock hardware VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only.
|
|
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { ncHardwareVpdEntry 16 }
|
|
|
|
-- ********************************************************************************
|
|
-- Multiplexer Expansion Module Hardware VPD
|
|
-- ********************************************************************************
|
|
mxHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 17 }
|
|
|
|
mxHardwareVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MxHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the Multiplexer Expansion Module hardware components.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mxHardwareVpd 1 }
|
|
|
|
mxHardwareVpdEntry OBJECT-TYPE
|
|
SYNTAX MxHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Multiplexer Expansion Module hardware VPD entry.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
INDEX { mxHardwareVpdIndex }
|
|
::= { mxHardwareVpdTable 1 }
|
|
|
|
MxHardwareVpdEntry ::= SEQUENCE {
|
|
mxHardwareVpdIndex INTEGER,
|
|
mxHardwareVpdBayNumber OCTET STRING,
|
|
mxHardwareVpdManufacturingId OCTET STRING,
|
|
mxHardwareVpdFruNumber OCTET STRING,
|
|
mxHardwareVpdHardwareRevision INTEGER,
|
|
mxHardwareVpdUuid OCTET STRING,
|
|
mxHardwareVpdManufDate OCTET STRING,
|
|
mxHardwareVpdPartNumber OCTET STRING,
|
|
mxHardwareVpdFruSerial OCTET STRING,
|
|
mxHardwareVpdManufacturingIDNumber OCTET STRING,
|
|
mxHardwareVpdProductId OCTET STRING,
|
|
mxHardwareVpdSubManufacturerId OCTET STRING,
|
|
mxHardwareVpdClei OCTET STRING,
|
|
mxHardwareVpdHardwareRevisionString OCTET STRING
|
|
}
|
|
|
|
mxHardwareVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Multiplexer Expansion Module hardware VPD index.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mxHardwareVpdEntry 1 }
|
|
|
|
mxHardwareVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Multiplexer Expansion Module hardware VPD Bay number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mxHardwareVpdEntry 2 }
|
|
|
|
mxHardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Multiplexer Expansion Module hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mxHardwareVpdEntry 3 }
|
|
|
|
mxHardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Multiplexer Expansion Module hardware VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mxHardwareVpdEntry 4 }
|
|
|
|
|
|
mxHardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Multiplexer Expansion Module hardware VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only.
|
|
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { mxHardwareVpdEntry 5 }
|
|
|
|
mxHardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Multiplexer Expansion Module hardware VPD UUID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mxHardwareVpdEntry 8 }
|
|
|
|
mxHardwareVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Multiplexer Expansion Module hardware VPD manufacture Date.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mxHardwareVpdEntry 9 }
|
|
|
|
mxHardwareVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Multiplexer Expansion Module hardware VPD Part Number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mxHardwareVpdEntry 10 }
|
|
|
|
mxHardwareVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Multiplexer Expansion Module hardware VPD FRU Serial Number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { mxHardwareVpdEntry 11 }
|
|
|
|
mxHardwareVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Multiplexer Expansion Module hardware VPD manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mxHardwareVpdEntry 12 }
|
|
|
|
mxHardwareVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Multiplexer Expansion Module hardware VPD product ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mxHardwareVpdEntry 13 }
|
|
|
|
mxHardwareVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Multiplexer Expansion Module hardware VPD subsystem manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mxHardwareVpdEntry 14 }
|
|
|
|
mxHardwareVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Multiplexer Expansion Module hardware VPD Common
|
|
Language Equipment Identifier (CLEI).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { mxHardwareVpdEntry 15 }
|
|
|
|
mxHardwareVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Multiplexer Expansion Module hardware VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only.
|
|
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { mxHardwareVpdEntry 16 }
|
|
|
|
-- ********************************************************************************
|
|
-- Storage Module Hardware VPD
|
|
-- ********************************************************************************
|
|
stmHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 18 }
|
|
|
|
stmHardwareVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF StmHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the Storage Module hardware components.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { stmHardwareVpd 1 }
|
|
|
|
stmHardwareVpdEntry OBJECT-TYPE
|
|
SYNTAX StmHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module hardware VPD entry.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
INDEX { stmHardwareVpdIndex }
|
|
::= { stmHardwareVpdTable 1 }
|
|
|
|
StmHardwareVpdEntry ::= SEQUENCE {
|
|
stmHardwareVpdIndex INTEGER,
|
|
stmHardwareVpdBayNumber OCTET STRING,
|
|
stmHardwareVpdManufacturingId OCTET STRING,
|
|
stmHardwareVpdFruNumber OCTET STRING,
|
|
stmHardwareVpdHardwareRevision INTEGER,
|
|
stmHardwareVpdUuid OCTET STRING,
|
|
stmHardwareVpdManufDate OCTET STRING,
|
|
stmHardwareVpdPartNumber OCTET STRING,
|
|
stmHardwareVpdFruSerial OCTET STRING,
|
|
stmHardwareVpdManufacturingIDNumber OCTET STRING,
|
|
stmHardwareVpdProductId OCTET STRING,
|
|
stmHardwareVpdSubManufacturerId OCTET STRING,
|
|
stmHardwareVpdClei OCTET STRING,
|
|
stmHardwareVpdHardwareRevisionString OCTET STRING
|
|
}
|
|
|
|
stmHardwareVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module hardware VPD index.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { stmHardwareVpdEntry 1 }
|
|
|
|
stmHardwareVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module hardware VPD Bay number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { stmHardwareVpdEntry 2 }
|
|
|
|
stmHardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { stmHardwareVpdEntry 3 }
|
|
|
|
stmHardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module hardware VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { stmHardwareVpdEntry 4 }
|
|
|
|
|
|
stmHardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module hardware VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only.
|
|
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then the HardwareRevisionString version of this MIB object should be used."
|
|
::= { stmHardwareVpdEntry 5 }
|
|
|
|
stmHardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module hardware VPD UUID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { stmHardwareVpdEntry 8 }
|
|
|
|
stmHardwareVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module hardware VPD manufacture Date.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { stmHardwareVpdEntry 9 }
|
|
|
|
stmHardwareVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module hardware VPD Part Number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { stmHardwareVpdEntry 10 }
|
|
|
|
stmHardwareVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module hardware VPD FRU Serial Number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { stmHardwareVpdEntry 11 }
|
|
|
|
stmHardwareVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module hardware VPD manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { stmHardwareVpdEntry 12 }
|
|
|
|
stmHardwareVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module hardware VPD product ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { stmHardwareVpdEntry 13 }
|
|
|
|
stmHardwareVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module hardware VPD subsystem manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { stmHardwareVpdEntry 14 }
|
|
|
|
stmHardwareVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module hardware VPD Common
|
|
Language Equipment Identifier (CLEI).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { stmHardwareVpdEntry 15 }
|
|
|
|
stmHardwareVpdHardwareRevisionString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module hardware VPD hardware revision in string format.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only.
|
|
|
|
If a hardware revision is programmed in the OEM VPD area for this component,
|
|
then this MIB object should be used."
|
|
::= { stmHardwareVpdEntry 16 }
|
|
|
|
-- ***********************************************************************
|
|
-- Storage Module Firmware VPD
|
|
-- ***********************************************************************
|
|
stmFirmwareVpd OBJECT IDENTIFIER ::= { vpdInformation 19 }
|
|
|
|
stmFirmwareVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF StmFirmwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the Storage Module firmware components.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { stmFirmwareVpd 1 }
|
|
|
|
stmFirmwareVpdEntry OBJECT-TYPE
|
|
SYNTAX StmFirmwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module firmware VPD entry.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
INDEX { stmFirmwareVpdIndex }
|
|
::= { stmFirmwareVpdTable 1 }
|
|
|
|
StmFirmwareVpdEntry ::= SEQUENCE {
|
|
stmFirmwareVpdIndex INTEGER,
|
|
stmFirmwareVpdType OCTET STRING,
|
|
stmFirmwareVpdBuildId OCTET STRING,
|
|
stmFirmwareVpdReleaseDate OCTET STRING,
|
|
stmFirmwareVpdRevision OCTET STRING
|
|
}
|
|
|
|
stmFirmwareVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module firmware VPD index.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { stmFirmwareVpdEntry 1 }
|
|
|
|
stmFirmwareVpdType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module firmware VPD type.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { stmFirmwareVpdEntry 2 }
|
|
|
|
stmFirmwareVpdBuildId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module firmware VPD build ID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { stmFirmwareVpdEntry 3 }
|
|
|
|
stmFirmwareVpdReleaseDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module firmware VPD release date.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { stmFirmwareVpdEntry 4 }
|
|
|
|
stmFirmwareVpdRevision OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module firmware VPD revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { stmFirmwareVpdEntry 5 }
|
|
|
|
-- ********************************************************************************
|
|
-- Battery Backup Unit Hardware VPD
|
|
-- ********************************************************************************
|
|
bbuHardwareVpd OBJECT IDENTIFIER ::= { vpdInformation 21 }
|
|
|
|
bbuHardwareVpdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BbuHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the Battery Backup Unit hardware components.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { bbuHardwareVpd 1 }
|
|
|
|
bbuHardwareVpdEntry OBJECT-TYPE
|
|
SYNTAX BbuHardwareVpdEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Backup Unit hardware VPD entry.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
INDEX { bbuHardwareVpdIndex }
|
|
::= { bbuHardwareVpdTable 1 }
|
|
|
|
BbuHardwareVpdEntry ::= SEQUENCE {
|
|
bbuHardwareVpdIndex INTEGER,
|
|
bbuHardwareVpdBayNumber OCTET STRING,
|
|
bbuHardwareVpdManufacturingId OCTET STRING,
|
|
bbuHardwareVpdFruNumber OCTET STRING,
|
|
bbuHardwareVpdHardwareRevision INTEGER,
|
|
bbuHardwareVpdUuid OCTET STRING,
|
|
bbuHardwareVpdManufDate OCTET STRING,
|
|
bbuHardwareVpdPartNumber OCTET STRING,
|
|
bbuHardwareVpdFruSerial OCTET STRING,
|
|
bbuHardwareVpdManufacturingIDNumber OCTET STRING,
|
|
bbuHardwareVpdProductId OCTET STRING,
|
|
bbuHardwareVpdSubManufacturerId OCTET STRING,
|
|
bbuHardwareVpdClei OCTET STRING
|
|
}
|
|
|
|
bbuHardwareVpdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Backup Unit hardware VPD index.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { bbuHardwareVpdEntry 1 }
|
|
|
|
bbuHardwareVpdBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Backup Unit hardware VPD Bay number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { bbuHardwareVpdEntry 2 }
|
|
|
|
bbuHardwareVpdManufacturingId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Backup Unit hardware VPD manufacturing ID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { bbuHardwareVpdEntry 3 }
|
|
|
|
bbuHardwareVpdFruNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Backup Unit hardware VPD FRU number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { bbuHardwareVpdEntry 4 }
|
|
|
|
|
|
bbuHardwareVpdHardwareRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Backup Unit hardware VPD hardware revision.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { bbuHardwareVpdEntry 5 }
|
|
|
|
bbuHardwareVpdUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Backup Unit hardware VPD UUID.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { bbuHardwareVpdEntry 8 }
|
|
|
|
bbuHardwareVpdManufDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Backup Unit hardware VPD manufacture Date.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { bbuHardwareVpdEntry 9 }
|
|
|
|
bbuHardwareVpdPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Backup Unit hardware VPD Part Number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { bbuHardwareVpdEntry 10 }
|
|
|
|
bbuHardwareVpdFruSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Backup Unit hardware VPD FRU Serial Number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { bbuHardwareVpdEntry 11 }
|
|
|
|
bbuHardwareVpdManufacturingIDNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Backup Unit hardware VPD manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bbuHardwareVpdEntry 12 }
|
|
|
|
bbuHardwareVpdProductId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Backup Unit hardware VPD product ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bbuHardwareVpdEntry 13 }
|
|
|
|
bbuHardwareVpdSubManufacturerId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Backup Unit hardware VPD subsystem manufacturer ID.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bbuHardwareVpdEntry 14 }
|
|
|
|
bbuHardwareVpdClei OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Battery Backup Unit hardware VPD Common
|
|
Language Equipment Identifier (CLEI).
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { bbuHardwareVpdEntry 15 }
|
|
|
|
-- ********************************************************************************
|
|
-- Reload VPD
|
|
-- ********************************************************************************
|
|
reloadVpdData OBJECT IDENTIFIER ::= { vpdInformation 23 }
|
|
|
|
reloadAllVpdData OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reload all VPD data (firmware, hardware, MAC address, WWN/GUID and other Unique ID).
|
|
NOTE: The value returned for the GET command is meaningless."
|
|
::= { reloadVpdData 1 }
|
|
|
|
reloadFwVpdData OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reload firmware VPD data.
|
|
NOTE: The value returned for the GET command is meaningless."
|
|
::= { reloadVpdData 2 }
|
|
|
|
reloadHwVpdData OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reload hardware VPD data.
|
|
NOTE: The value returned for the GET command is meaningless."
|
|
::= { reloadVpdData 3 }
|
|
|
|
reloadMACAddress OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reload blade MAC addresses.
|
|
NOTE: The value returned for the GET command is meaningless."
|
|
::= { reloadVpdData 4 }
|
|
|
|
reloadWwnGuidVpdData OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reload blade and I/O module WWN/GUID and other VPD data.
|
|
NOTE: The value returned for the GET command is meaningless."
|
|
::= { reloadVpdData 5 }
|
|
|
|
|
|
-- *************************************************************************
|
|
-- Passive Air Filter
|
|
-- *************************************************************************
|
|
|
|
airFilter OBJECT IDENTIFIER ::= { monitors 22 }
|
|
|
|
passiveAirFilter OBJECT IDENTIFIER ::= { airFilter 1 }
|
|
|
|
passiveAirFilterStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1),
|
|
reset(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable/Reset the passive air filter. When enabled, sending an enable or reset will reset the replace date.
|
|
The reset command is only applicable in BladeCenter Telco Refresh and it will restart the Fouled Filter Detection settings.
|
|
NOTE: This MIB object is only applicable for BladeCenter S, BladeCenter E Refresh, and BladeCenter Telco Refresh."
|
|
::= { passiveAirFilter 1 }
|
|
|
|
passiveAirFilterMonthFreq OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
oneMonth(1),
|
|
threeMonths(3),
|
|
sixMonths(6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The chassis environment. 1 month indicates high dust, 3 months indicates moderate dust and, 6 months indicates low dust.
|
|
NOTE: This MIB object is for BladeCenter S and BladeCenter E Refresh only."
|
|
::= { passiveAirFilter 2 }
|
|
|
|
passiveAirFilterReplaceDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..30))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The scheduled replacement date of the air filter.
|
|
NOTE: This MIB object is for BladeCenter S and BladeCenter E Refresh only."
|
|
::= { passiveAirFilter 3 }
|
|
|
|
|
|
-- *************************************************************************
|
|
-- Component Information
|
|
--
|
|
-- This anchor is for a new set of tables that provide information about all
|
|
-- of the components in the chassis. For example, the componentInventoryTable
|
|
-- provides inventory information for all components in a single table and the
|
|
-- componentFirmwareTable provides firmware information for all components in
|
|
-- a single table. In previously defined tables, this information was
|
|
-- scattered about several tables, while this new concept provides a more
|
|
-- concise presentation.
|
|
--
|
|
-- *************************************************************************
|
|
|
|
componentInformation OBJECT IDENTIFIER ::= { monitors 23 }
|
|
|
|
-- *************************************************************************
|
|
-- Component Inventory Information
|
|
-- *************************************************************************
|
|
componentInventory OBJECT IDENTIFIER ::= { componentInformation 1 }
|
|
|
|
componentInventoryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ComponentInventoryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of component inventory information. Not all components will
|
|
provide every object defined in the ComponentInventoryEntry."
|
|
::= { componentInventory 1 }
|
|
|
|
componentInventoryEntry OBJECT-TYPE
|
|
SYNTAX ComponentInventoryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Component inventory information."
|
|
INDEX { componentInventoryTopologyPath }
|
|
::= { componentInventoryTable 1 }
|
|
|
|
ComponentInventoryEntry ::= SEQUENCE {
|
|
componentInventoryTopologyPath OCTET STRING,
|
|
componentInventoryInstance INTEGER,
|
|
componentInventoryDescription OCTET STRING,
|
|
componentInventoryMachineTypeModel OCTET STRING,
|
|
componentInventoryMachineSerial OCTET STRING,
|
|
componentInventoryAssetID OCTET STRING,
|
|
componentInventoryPartNumber OCTET STRING,
|
|
componentInventoryFRUNumber OCTET STRING,
|
|
componentInventoryFRUSerialNumber OCTET STRING,
|
|
componentInventoryManufactureID OCTET STRING,
|
|
componentInventoryHardwareRevision OCTET STRING,
|
|
componentInventoryManufactureDate OCTET STRING,
|
|
componentInventoryUUID OCTET STRING,
|
|
componentInventoryProductID OCTET STRING,
|
|
componentInventorySubManufactureID OCTET STRING,
|
|
componentInventoryCLEI OCTET STRING,
|
|
componentInventoryAssetTag OCTET STRING,
|
|
componentInventorySpeed OCTET STRING,
|
|
componentInventoryIdentifier OCTET STRING,
|
|
componentInventorySize INTEGER,
|
|
componentInventoryMemoryType INTEGER,
|
|
componentInventoryProductName OCTET STRING,
|
|
componentInventoryProductVersion OCTET STRING,
|
|
componentInventoryProcessorType INTEGER,
|
|
componentInventoryProcessorFamily OCTET STRING,
|
|
componentInventoryProcessorCores OCTET STRING,
|
|
componentInventoryProcessorThreads OCTET STRING,
|
|
componentInventoryProcessorL1DCache OCTET STRING,
|
|
componentInventoryProcessorL1ICache OCTET STRING,
|
|
componentInventoryProcessorL2Cache OCTET STRING,
|
|
componentInventoryProcessorL3Cache OCTET STRING,
|
|
componentInventoryProcessorVoltage OCTET STRING,
|
|
componentInventoryProcessorExtClock OCTET STRING,
|
|
componentInventoryProcessorDataWidth OCTET STRING,
|
|
componentInventoryManufactureIDNum INTEGER
|
|
}
|
|
|
|
componentInventoryTopologyPath OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..100))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unique identifier for a row in this table. The chassis and each
|
|
installed component is represented by a hardware topology tree, where
|
|
each node in the tree represents a component. The path to a particular
|
|
component consists of one or more <component>,<instance> pairs, where
|
|
each successive pair is a child of the previous parent pair.
|
|
|
|
As an example, the root of the tree is the chassis and is represented
|
|
by the pair 'CHASSIS, 1'. This pair indicates the first instance of
|
|
the chassis. If a blade is inserted in slot 4 of the chassis, its
|
|
topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the
|
|
components in the chassis can be determined along with their relative
|
|
hierarchy to each other.
|
|
|
|
This component inventory table is indexed by this unique topology
|
|
path and the numeric designations for the components are:
|
|
|
|
CHASSIS, 0x01 Chassis
|
|
MM, 0x02 Management Module
|
|
BLADE, 0x03 Main system board of a blade
|
|
POWER, 0x04 Power Supply, Power Module, etc
|
|
COOLING, 0x05 Fan, blower, or other cooling device
|
|
IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge
|
|
MEDIA, 0x07 Media device
|
|
PROCESSOR, 0x08 Any processor, processor module, etc
|
|
STORAGE, 0x09 Any type of storage device
|
|
EXPANSION, 0x0A Expansion Card (not covered by more specific type)
|
|
MEMORY, 0x0B Any memory device, module, etc
|
|
MFRU, 0x0C Managed FRU Device
|
|
PANEL, 0x0D Any sort of panel device, such as a front panel
|
|
BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc
|
|
CARD_EXPANSION, 0x0F Expansion card, ie. daughter card
|
|
CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card
|
|
INTERPOSER, 0x11 Interposer device
|
|
CLOCK, 0x12 Clock card
|
|
MUX, 0x13 Mulitplexer card
|
|
ADDIN, 0x14 cKVM card & other addin cards
|
|
STORAGE_MODULE, 0x15 Container of one or more Storage Devices
|
|
SYS_EXPANSION_CARD, 0x16 Management card
|
|
BATTERY, 0x17 A single battery
|
|
BATTERY_MODULE, 0x18 Container of one or more batteries
|
|
MEDIA_MODULE, 0x19 Container of one or more media devices
|
|
MEMORY_BANK, 0x1A Memory banks
|
|
AIR_FILTER, 0x1B Filter mechanism (bezel)
|
|
SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports
|
|
PARENT, 0x1D Reference to parent for multi-parent support
|
|
PHY_PORT, 0x1E Physical port
|
|
IO_EXPANDER, 0x1F RAID card"
|
|
|
|
::= { componentInventoryEntry 1 }
|
|
|
|
componentInventoryInstance OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The slot number or instance of a particular component. Typically,
|
|
if the component plugs into the chassis, this represents the slot
|
|
number. However, some components are connected to another component,
|
|
and this represents the instance. For example, a blade may have
|
|
several expansion cards that connect to the blade system planar,
|
|
and in this case, this value identifies which expansion card
|
|
instance the row represents.
|
|
|
|
Note that this slot/instance value can be determined from the
|
|
componentInventoryTopologyPath object, but this
|
|
componentInventoryInstance object is provided as a convenience
|
|
to the user."
|
|
::= { componentInventoryEntry 2 }
|
|
|
|
componentInventoryDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A short text string describing the particular component. For the
|
|
AMM and blades, this name will be the configured name or its
|
|
serial number if no user configured name is available. For all
|
|
other components, this object will provide text to identify the
|
|
component. If a text string is not available, a value of
|
|
'Not available' is presented.
|
|
|
|
For more detail, also refer to the componentInventoryProductName
|
|
object."
|
|
::= { componentInventoryEntry 3 }
|
|
|
|
componentInventoryMachineTypeModel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The machine type and model number of this component. Typically,
|
|
the format is XXXXYYY, where XXXX reprsents the machine type
|
|
and YYY represents the model number."
|
|
::= { componentInventoryEntry 4 }
|
|
|
|
componentInventoryMachineSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The machine serial number of this component."
|
|
::= { componentInventoryEntry 5 }
|
|
|
|
componentInventoryAssetID OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The asset identifier of this component, typically set by some
|
|
other authority than the
|
|
manufacturer."
|
|
::= { componentInventoryEntry 6 }
|
|
|
|
componentInventoryPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The part number of this component."
|
|
::= { componentInventoryEntry 7 }
|
|
|
|
componentInventoryFRUNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Field Replaceable Unit (FRU) number of this component."
|
|
::= { componentInventoryEntry 8 }
|
|
|
|
componentInventoryFRUSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Field Replaceable Unit (FRU) serial number of this component."
|
|
::= { componentInventoryEntry 9 }
|
|
|
|
componentInventoryManufactureID OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The text description of the manufacturer of this component."
|
|
::= { componentInventoryEntry 10 }
|
|
|
|
componentInventoryHardwareRevision OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware revision number of the this component."
|
|
::= { componentInventoryEntry 11 }
|
|
|
|
componentInventoryManufactureDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date when the manufacturer created this component. The format
|
|
is XXYY, where XX is the week number of the year 20YY."
|
|
::= { componentInventoryEntry 12 }
|
|
|
|
componentInventoryUUID OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Universally Unique IDentifier (UUID) of this component, represented
|
|
as a 16 byte hex number."
|
|
::= { componentInventoryEntry 13 }
|
|
|
|
componentInventoryProductID OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The product identifier of the component assigned by the
|
|
manufacturer."
|
|
::= { componentInventoryEntry 14 }
|
|
|
|
componentInventorySubManufactureID OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The text sub-description of the manufacturer of this component, often
|
|
used to identify a supplier for a component which has multiple
|
|
suppliers."
|
|
::= { componentInventoryEntry 15 }
|
|
|
|
componentInventoryCLEI OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Common Language Equipment Identifier (CLEI) of this component."
|
|
::= { componentInventoryEntry 16 }
|
|
|
|
componentInventoryAssetTag OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The asset tag of this component."
|
|
::= { componentInventoryEntry 17 }
|
|
|
|
componentInventorySpeed OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A speed designation for the component, for example, processor
|
|
speed."
|
|
::= { componentInventoryEntry 18 }
|
|
|
|
componentInventoryIdentifier OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique identifier assigned by the manufacturer to the
|
|
component, for example,
|
|
a processor ID."
|
|
::= { componentInventoryEntry 19 }
|
|
|
|
componentInventorySize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A size designation for the component, for example, a memory
|
|
DIMM size
|
|
or hard drive capacity."
|
|
::= { componentInventoryEntry 20 }
|
|
|
|
componentInventoryMemoryType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fpmdram(1),
|
|
edo(2),
|
|
edodram(3),
|
|
sdram(4),
|
|
multiplexedram(5),
|
|
ddrsgram(6),
|
|
ddrsdram(7),
|
|
ddr2sdrm(8),
|
|
ddr3sdram(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The architecture specification of a memory device."
|
|
::= { componentInventoryEntry 21 }
|
|
|
|
componentInventoryProductName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The product name assigned by the manufacturer for this component.
|
|
|
|
For more detail, also refer to the componentInventoryDescription
|
|
object."
|
|
::= { componentInventoryEntry 22 }
|
|
|
|
componentInventoryProductVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The product version assigned by the manufacturer for this
|
|
component."
|
|
::= { componentInventoryEntry 23 }
|
|
|
|
componentInventoryProcessorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
unknown(2),
|
|
central(3),
|
|
math(4),
|
|
dsp(5),
|
|
video(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type designation for processor components."
|
|
::= { componentInventoryEntry 24 }
|
|
|
|
componentInventoryProcessorFamily OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The family designation for processor components."
|
|
::= { componentInventoryEntry 25 }
|
|
|
|
componentInventoryProcessorCores OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of cores present on a processor component."
|
|
::= { componentInventoryEntry 26 }
|
|
|
|
componentInventoryProcessorThreads OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of threads present on a processor component."
|
|
::= { componentInventoryEntry 27 }
|
|
|
|
componentInventoryProcessorL1DCache OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The level 1 data cache size of a processor component."
|
|
::= { componentInventoryEntry 28 }
|
|
|
|
componentInventoryProcessorL1ICache OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The level 1 instruction cache size of a processor component."
|
|
::= { componentInventoryEntry 29 }
|
|
|
|
componentInventoryProcessorL2Cache OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The level 2 cache size of a processor component."
|
|
::= { componentInventoryEntry 30 }
|
|
|
|
componentInventoryProcessorL3Cache OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The level 3 cache size of a processor component."
|
|
::= { componentInventoryEntry 31 }
|
|
|
|
componentInventoryProcessorVoltage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The voltage rating for a processor component."
|
|
::= { componentInventoryEntry 32 }
|
|
|
|
componentInventoryProcessorExtClock OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The external clock speed of a processor component."
|
|
::= { componentInventoryEntry 33 }
|
|
|
|
componentInventoryProcessorDataWidth OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum data bus width capability of a processor component,
|
|
expressed typically in bits."
|
|
::= { componentInventoryEntry 34 }
|
|
|
|
componentInventoryManufactureIDNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The identification number assigned for the component by the manufacturer."
|
|
::= { componentInventoryEntry 35 }
|
|
|
|
|
|
-- *************************************************************************
|
|
-- Component Firmware Information
|
|
-- *************************************************************************
|
|
componentFirmware OBJECT IDENTIFIER ::= { componentInformation 2 }
|
|
|
|
componentFirmwareTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ComponentFirmwareEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of component firmware information. Not all components will
|
|
provide every object defined in the ComponentFirmwareEntry."
|
|
::= { componentFirmware 1 }
|
|
|
|
componentFirmwareEntry OBJECT-TYPE
|
|
SYNTAX ComponentFirmwareEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Component firmware information."
|
|
INDEX { componentFirmwareTopologyPath, componentFirmwareIndex }
|
|
::= { componentFirmwareTable 1 }
|
|
|
|
ComponentFirmwareEntry ::= SEQUENCE {
|
|
componentFirmwareTopologyPath OCTET STRING,
|
|
componentFirmwareIndex INTEGER,
|
|
componentFirmwareComponentInstance INTEGER,
|
|
componentFirmwareComponentDescription OCTET STRING,
|
|
componentFirmwareType OCTET STRING,
|
|
componentFirmwareBuildID OCTET STRING,
|
|
componentFirmwareReleaseDate OCTET STRING,
|
|
componentFirmwareFilename OCTET STRING,
|
|
componentFirmwareRevision OCTET STRING,
|
|
componentFirmwareRevisionMajor INTEGER,
|
|
componentFirmwareRevisionMinor INTEGER,
|
|
componentFirmwareLevelStatus OCTET STRING,
|
|
componentFirmwarePendingBuildID OCTET STRING,
|
|
componentFirmwarePendingReleaseDate OCTET STRING,
|
|
componentFirmwarePendingRevision OCTET STRING,
|
|
componentFirmwareTypeID INTEGER
|
|
}
|
|
|
|
componentFirmwareTopologyPath OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..100))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unique identifier for a component in this table. The chassis and each
|
|
installed component is represented by a hardware topology tree, where
|
|
each node in the tree represents a component. The path to a particular
|
|
component consists of one or more <component>,<instance> pairs, where
|
|
each successive pair is a child of the previous parent pair.
|
|
|
|
As an example, the root of the tree is the chassis and is represented
|
|
by the pair 'CHASSIS, 1'. This pair indicates the first instance of
|
|
the chassis. If a blade is inserted in slot 4 of the chassis, its
|
|
topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the
|
|
components in the chassis can be determined along with their relative
|
|
hierarchy to each other.
|
|
|
|
Note that this TP is preceded by a single octet that specifies the TP length.
|
|
This is required since this table is indexed with two indices and, therefore,
|
|
the TP length must be explicitly provided.
|
|
|
|
This component firmware table is indexed by this unique topology
|
|
path and the numeric designations for the components are:
|
|
|
|
CHASSIS, 0x01 Chassis
|
|
MM, 0x02 Management Module
|
|
BLADE, 0x03 Main system board of a blade
|
|
POWER, 0x04 Power Supply, Power Module, etc
|
|
COOLING, 0x05 Fan, blower, or other cooling device
|
|
IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge
|
|
MEDIA, 0x07 Media device
|
|
PROCESSOR, 0x08 Any processor, processor module, etc
|
|
STORAGE, 0x09 Any type of storage device
|
|
EXPANSION, 0x0A Expansion Card (not covered by more specific type)
|
|
MEMORY, 0x0B Any memory device, module, etc
|
|
MFRU, 0x0C Managed FRU Device
|
|
PANEL, 0x0D Any sort of panel device, such as a front panel
|
|
BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc
|
|
CARD_EXPANSION, 0x0F Expansion card, ie. daughter card
|
|
CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card
|
|
INTERPOSER, 0x11 Interposer device
|
|
CLOCK, 0x12 Clock card
|
|
MUX, 0x13 Mulitplexer card
|
|
ADDIN, 0x14 cKVM card & other addin cards
|
|
STORAGE_MODULE, 0x15 Container of one or more Storage Devices
|
|
SYS_EXPANSION_CARD, 0x16 Management card
|
|
BATTERY, 0x17 A single battery
|
|
BATTERY_MODULE, 0x18 Container of one or more batteries
|
|
MEDIA_MODULE, 0x19 Container of one or more media devices
|
|
MEMORY_BANK, 0x1A Memory banks
|
|
AIR_FILTER, 0x1B Filter mechanism (bezel)
|
|
SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports
|
|
PARENT, 0x1D Reference to parent for multi-parent support
|
|
PHY_PORT, 0x1E Physical port
|
|
IO_EXPANDER, 0x1F RAID card"
|
|
|
|
::= { componentFirmwareEntry 1 }
|
|
|
|
componentFirmwareIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Each component may have one or more types of firmware associated with it, and this index object
|
|
identifies the particular instance."
|
|
::= { componentFirmwareEntry 2 }
|
|
|
|
componentFirmwareComponentInstance OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The slot number or instance of a particular component. Typically,
|
|
if the component plugs into the chassis, this represents the slot
|
|
number. However, some components are connected to another component,
|
|
and this represents the instance. For example, a blade may have
|
|
several expansion cards that connect to the blade system planar,
|
|
and in this case, this value identifies which expansion card
|
|
instance the row represents.
|
|
|
|
Note that this slot/instance value can be determined from the
|
|
componentFirmwareTopologyPath object, but this
|
|
componentFirmwareComponentInstance object is provided as a convenience
|
|
to the user."
|
|
::= { componentFirmwareEntry 3 }
|
|
|
|
componentFirmwareComponentDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A short text string describing the particular component. For the
|
|
AMM and blades, this name will be the configured name or its
|
|
serial number if no user configured name is available. For all
|
|
other components, this object will provide text to identify the
|
|
component. If a text string is not available, a value of
|
|
'Not available' is presented.
|
|
|
|
For more detail, also refer to the componentInventoryProductName
|
|
object."
|
|
::= { componentFirmwareEntry 4 }
|
|
|
|
componentFirmwareType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text description of the type of firmware load."
|
|
::= { componentFirmwareEntry 5 }
|
|
|
|
componentFirmwareBuildID OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text description of the build identifier for this firmware load."
|
|
::= { componentFirmwareEntry 6 }
|
|
|
|
componentFirmwareReleaseDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text description of the release date for this firmware load."
|
|
::= { componentFirmwareEntry 7 }
|
|
|
|
componentFirmwareFilename OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text description of the filename of this firmware load."
|
|
::= { componentFirmwareEntry 8 }
|
|
|
|
componentFirmwareRevision OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text description of the revision level of this firmware load."
|
|
::= { componentFirmwareEntry 9 }
|
|
|
|
componentFirmwareRevisionMajor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A numeric identifier of the revision major number for this firmware load."
|
|
::= { componentFirmwareEntry 10 }
|
|
|
|
componentFirmwareRevisionMinor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A numeric identifier of the revision minor number for this firmware load."
|
|
::= { componentFirmwareEntry 11 }
|
|
|
|
componentFirmwareLevelStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The level status of the firmware build ID.
|
|
It has three possible values as Different (mismatch firmware build ID), Match (the
|
|
same firmware build ID), Unique (only one such firmware build ID)."
|
|
::= { componentFirmwareEntry 12 }
|
|
|
|
componentFirmwarePendingBuildID OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text description of the build identifier for this pending firmware load."
|
|
::= { componentFirmwareEntry 13 }
|
|
|
|
componentFirmwarePendingReleaseDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text description of the release date for this pending firmware load."
|
|
::= { componentFirmwareEntry 14 }
|
|
|
|
componentFirmwarePendingRevision OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text description of the revision level of this pending firmware load."
|
|
::= { componentFirmwareEntry 15 }
|
|
|
|
componentFirmwareTypeID OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bladeFwBios(1),
|
|
bladeDiagnostics(2),
|
|
bladeSysMgmtProcessor(3),
|
|
bladeFpga(4),
|
|
bladecKVM(5),
|
|
switchModuleMainAppl1(41),
|
|
switchModuleMainAppl2(42),
|
|
switchModuleBootROM(43),
|
|
mgmtModuleMainAppl(61),
|
|
mgmtModuleMainApplPendingRestart(62),
|
|
fanController(81),
|
|
unknown(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the type of firmware load with a numeric identifier."
|
|
::= { componentFirmwareEntry 20 }
|
|
|
|
|
|
componentInventoryReady OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notReady(0),
|
|
ready(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When a blade management controller or the AMM is reset, the
|
|
blade inventory data is refreshed in the AMM database. This includes
|
|
items like IBM VPD (e.g. - serial number, UUID) and MAC address information.
|
|
|
|
Applications need to know when this information has been populated on the AMM
|
|
before they begin to query it using SNMP or other means. This simple flag
|
|
object will return a ready or notReady indication when all blades have completed
|
|
initialization and the inventory information has been provided to the AMM.
|
|
|
|
Note that due to blades that may be experiencing a 'communication failure' or
|
|
'initialization failure' condition, this object may continue to show notReady.
|
|
Therefore, any application that polls this object should also incorporate a timeout
|
|
period. As of AMM release v5.3, a 10 minute timeout seems to be a minimum suggested
|
|
polling period.
|
|
|
|
A more granular, per-blade status is available via the bladeSystemStatusTable"
|
|
::= { componentInformation 3 }
|
|
|
|
|
|
componentDriveTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ComponentDriveEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of information indicating presence of a disk drive on a component.
|
|
The management module does not receive any inventory VPD from the
|
|
component, so only the presence of a drive can be indicated by this table."
|
|
::= { componentInformation 10 }
|
|
|
|
componentDriveEntry OBJECT-TYPE
|
|
SYNTAX ComponentDriveEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Component drive information."
|
|
INDEX { componentDriveTopologyPath }
|
|
::= { componentDriveTable 1 }
|
|
|
|
ComponentDriveEntry ::= SEQUENCE {
|
|
componentDriveTopologyPath OCTET STRING,
|
|
componentDriveDescription OCTET STRING
|
|
}
|
|
|
|
componentDriveTopologyPath OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..100))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unique identifier for a row in this table. The chassis and each
|
|
installed component is represented by a hardware topology tree, where
|
|
each node in the tree represents a component. The path to a particular
|
|
component consists of one or more <component>,<instance> pairs, where
|
|
each successive pair is a child of the previous parent pair.
|
|
|
|
As an example, the root of the tree is the chassis and is represented
|
|
by the pair 'CHASSIS, 1'. This pair indicates the first instance of
|
|
the chassis. If a blade is inserted in slot 4 of the chassis, its
|
|
topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the
|
|
components in the chassis can be determined along with their relative
|
|
hierarchy to each other.
|
|
|
|
This component table is indexed by this unique topology
|
|
path and the numeric designations for the components are:
|
|
|
|
CHASSIS, 0x01 Chassis
|
|
MM, 0x02 Management Module
|
|
BLADE, 0x03 Main system board of a blade
|
|
POWER, 0x04 Power Supply, Power Module, etc
|
|
COOLING, 0x05 Fan, blower, or other cooling device
|
|
IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge
|
|
MEDIA, 0x07 Media device
|
|
PROCESSOR, 0x08 Any processor, processor module, etc
|
|
STORAGE, 0x09 Any type of storage device
|
|
EXPANSION, 0x0A Expansion Card (not covered by more specific type)
|
|
MEMORY, 0x0B Any memory device, module, etc
|
|
MFRU, 0x0C Managed FRU Device
|
|
PANEL, 0x0D Any sort of panel device, such as a front panel
|
|
BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc
|
|
CARD_EXPANSION, 0x0F Expansion card, ie. daughter card
|
|
CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card
|
|
INTERPOSER, 0x11 Interposer device
|
|
CLOCK, 0x12 Clock card
|
|
MUX, 0x13 Mulitplexer card
|
|
ADDIN, 0x14 cKVM card & other addin cards
|
|
STORAGE_MODULE, 0x15 Container of one or more Storage Devices
|
|
SYS_EXPANSION_CARD, 0x16 Management card
|
|
BATTERY, 0x17 A single battery
|
|
BATTERY_MODULE, 0x18 Container of one or more batteries
|
|
MEDIA_MODULE, 0x19 Container of one or more media devices
|
|
MEMORY_BANK, 0x1A Memory banks
|
|
AIR_FILTER, 0x1B Filter mechanism (bezel)
|
|
SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports
|
|
PARENT, 0x1D Reference to parent for multi-parent support
|
|
PHY_PORT, 0x1E Physical port
|
|
IO_EXPANDER, 0x1F RAID card"
|
|
::= { componentDriveEntry 1 }
|
|
|
|
componentDriveDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A short text string describing the particular drive on the component."
|
|
::= { componentDriveEntry 2 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- MM Security Settings
|
|
-- ********************************************************************************
|
|
securitySettings OBJECT IDENTIFIER ::= { configureSP 3 }
|
|
|
|
dataEncryption OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If enabled, all confidential data will be encrypted. The default value is disabled.
|
|
NOTE: Once the data is encrypted, the only way to reverse this process is to
|
|
reset to default values."
|
|
::= { securitySettings 1 }
|
|
|
|
trespassWarning OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If enabled, a customizable trespass warning message is displayed via the Web
|
|
and CLI interfaces."
|
|
::= { securitySettings 2 }
|
|
|
|
trespassWarningDefault OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset the trespass warning to default value.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { securitySettings 3 }
|
|
|
|
trespassMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..1600))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of the trespass warning message."
|
|
::= { securitySettings 4 }
|
|
|
|
-- ********************************************************************************
|
|
-- MM Clock
|
|
-- ********************************************************************************
|
|
spClock OBJECT IDENTIFIER ::= { configureSP 4 }
|
|
|
|
spClockDateAndTimeSetting OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM clock date and time setting.
|
|
A date-time specification for the local time of day.
|
|
For example to set the date and time to
|
|
March 4, 2001 at 06:00:00AM, set the value to:'03/04/2001,06:00:00'.
|
|
field contents range
|
|
_____ ________ _____
|
|
1 month 01..12
|
|
2 separator '/'
|
|
3 day 01..31
|
|
4 separator '/'
|
|
5 year 2000..2089
|
|
6 separator ','
|
|
7 hour 00..23
|
|
8 separator ':'
|
|
9 minutes 00..59
|
|
10 separator ':'
|
|
11 seconds 00..59
|
|
"
|
|
::= { spClock 1 }
|
|
|
|
spClockTimezoneSetting OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM clock Greenwich Mean Time(GMT) offset and Daylight Saving Time(DST)
|
|
settings.
|
|
|
|
The following table lists GMT offsets and associated DST
|
|
information. DST is not observed in time zones where
|
|
the 'Observe DST' value does not contain 'yes' in the table.
|
|
Also, note that in some cases additional information
|
|
is required to determine the clock adjustment when DST is
|
|
observed. The additional information is required when the
|
|
GMT offset being written is +2:00 or +10:00.
|
|
|
|
Examples
|
|
-to set the GMT offset to +3:30,
|
|
set the value to:'+3:30,no'
|
|
|
|
-for Eastern Standard Time and observing DST,
|
|
set the value to:'-5:00,yes'
|
|
|
|
-for Egypt and observing DST,
|
|
set the value to:'+2:00,yes,6'
|
|
|
|
|
|
GMT Observe Additional
|
|
Offset DST? DST value
|
|
______ _______ __________
|
|
+0:00 yes|no
|
|
+1:00 yes|no
|
|
+2:00 yes|no When 'Observe DST?' value is 'yes':
|
|
5 (for E.Europe)
|
|
4 (for GTB)
|
|
6 (for Egypt)
|
|
7 (for FLE)
|
|
+3:00 yes|no
|
|
+3:30 yes|no
|
|
+4:00 no
|
|
+4:30 no
|
|
+5:00 yes|no
|
|
+5:30 no
|
|
+6:00 no
|
|
+7:00 no
|
|
+8:00 yes|no
|
|
+9:00 yes|no
|
|
+9:30 yes|no When 'Observe DST?' value is 'yes':
|
|
10 (for South AUS)
|
|
9 (for other locations)
|
|
+10:00 yes|no When 'Observe DST?' value is 'yes':
|
|
9 (for AUS Eastern)
|
|
10 (for TAS,ACT,NSW,VIC)
|
|
4 (for Vladivostok)
|
|
+11:00 no
|
|
+12:00 yes|no
|
|
-12:00 no
|
|
-11:00 no
|
|
-10:00 no
|
|
-9:00 yes|no When 'Observe DST?' value is 'yes':
|
|
12 (for USA and Canada)
|
|
1 (for other locations)
|
|
-8:00 yes|no When 'Observe DST?' value is 'yes':
|
|
12 (for USA and Canada)
|
|
1 (for other locations)
|
|
-7:00 yes|no When 'Observe DST?' value is 'yes':
|
|
12 (for USA and Canada)
|
|
1 (for other locations)
|
|
-6:00 yes|no When 'Observe DST?' value is 'yes':
|
|
12 (for USA and Canada)
|
|
1 (for other locations)
|
|
-5:00 yes|no When 'Observe DST?' value is 'yes':
|
|
12 (for USA and Canada)
|
|
1 (for other locations)
|
|
-4:00 yes|no When 'Observe DST' value is 'yes':
|
|
12 (for Canada)
|
|
1 (for other locations)
|
|
-3:30 yes|no
|
|
-3:00 yes|no
|
|
-2:00 yes|no
|
|
-1:00 yes|no
|
|
"
|
|
::= { spClock 2 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- MM identification
|
|
-- ********************************************************************************
|
|
spIdentification OBJECT IDENTIFIER ::= { configureSP 5 }
|
|
|
|
spTxtId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MM text ID.
|
|
NOTE: Do not put any 'space characters' at end of the ID."
|
|
::= { spIdentification 1 }
|
|
|
|
-- ********************************************************************************
|
|
-- Network Configuration
|
|
-- ********************************************************************************
|
|
networkConfiguration OBJECT IDENTIFIER ::= { configureSP 9 }
|
|
|
|
-- ********************************************************************************
|
|
-- Network Interfaces
|
|
-- ********************************************************************************
|
|
networkInterfaces OBJECT IDENTIFIER ::= { networkConfiguration 1 }
|
|
-- ********************************************************************************
|
|
-- Ethernet Interface 1
|
|
-- ********************************************************************************
|
|
extEthernetInterface OBJECT IDENTIFIER ::= { networkInterfaces 1 }
|
|
|
|
extEthernetInterfaceType OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of interface. Indicates 'Ethernet-1'."
|
|
::= { extEthernetInterface 1 }
|
|
|
|
extEthernetInterfaceHostName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the 64 byte null terminated DNS host name for this
|
|
interface."
|
|
::= { extEthernetInterface 3 }
|
|
|
|
extEthernetInterfaceIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the IP address for the ethernet interface."
|
|
::= { extEthernetInterface 4 }
|
|
|
|
extEthernetInterfaceDataRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enet10Megabit(3),
|
|
enet100Megabit(4),
|
|
autoSpeed(5),
|
|
enet1GigabitAuto(6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the data transfer rate to be used over the ethernet
|
|
interface: 10Mb, 100Mb, 1G Auto or Auto.
|
|
|
|
Note that not all AMM hardware supports the 1G Auto speed. If it does not
|
|
and a SET of this value is attempted, it will be rejected with a
|
|
badValue return code.
|
|
|
|
When a user selects the 1G Auto setting, the duplex setting will be forced to
|
|
fullDuplex."
|
|
::= { extEthernetInterface 5 }
|
|
|
|
extEthernetInterfaceDuplexSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fullDuplex(1),
|
|
halfDuplex(2),
|
|
autoDuplex(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the duplex settings for the data transfer rate to be used over
|
|
the ethernet interface: Half, Full, or Auto.
|
|
|
|
When a user selects the 1G Auto speed setting, the duplex setting will be forced to
|
|
fullDuplex."
|
|
::= { extEthernetInterface 6 }
|
|
|
|
extEthernetInterfaceLAA OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(17))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the locally administered MAC address. The locally administered
|
|
address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This
|
|
value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and
|
|
A - F. This MM subsystem does not allow use of a multicast address. A multicast
|
|
address has the least significant bit of the first byte set to a 1. The first
|
|
byte must, therefore, be an even number.
|
|
|
|
NOTE: Although the locally administered MAC address can be assigned the same value
|
|
for the primary and backup AMM, it is not recommended."
|
|
::= { extEthernetInterface 7 }
|
|
|
|
extEthernetInterfaceDhcpEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dhcpDisabled(0),
|
|
dhcpEnabled(1),
|
|
tryDhcpThenTryStatic(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable or enable DHCP on this interface."
|
|
::= { extEthernetInterface 8 }
|
|
|
|
extEthernetInterfaceGatewayIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the IP address of the gateway/router for the ethernet
|
|
interface."
|
|
::= { extEthernetInterface 9 }
|
|
|
|
extEthernetInterfaceBIA OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(17))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the burned-in MAC (BIA) address."
|
|
::= { extEthernetInterface 10 }
|
|
|
|
extEthernetInterfaceMTU OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the Maximum Transmission Unit(MTU) for the ethernet
|
|
interface"
|
|
::= { extEthernetInterface 13 }
|
|
|
|
extEthernetInterfaceSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the subnet mask for the ethernet interface"
|
|
::= { extEthernetInterface 14 }
|
|
|
|
-- ********************************************************************************
|
|
-- DHCP Server Assigned Settings for ethernet interface 1
|
|
-- ********************************************************************************
|
|
|
|
dhcpEthernetInterface OBJECT IDENTIFIER ::= { extEthernetInterface 16 }
|
|
|
|
dhcpHostName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the 64 byte null terminated DNS host name for this
|
|
interface, assigned by the DHCP server."
|
|
::= { dhcpEthernetInterface 1 }
|
|
|
|
dhcpIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the IP address for the ethernet interface,
|
|
assigned by the DHCP server."
|
|
::= { dhcpEthernetInterface 2 }
|
|
|
|
dhcpGatewayIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the IP address of the gateway/router for the ethernet
|
|
interface, assigned by the DHCP server."
|
|
::= { dhcpEthernetInterface 3 }
|
|
|
|
dhcpSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the Subnet Mask for the ethernet
|
|
interface, assigned by the DHCP server."
|
|
::= { dhcpEthernetInterface 4 }
|
|
|
|
dhcpDomainName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the 64 byte null terminated Domain Name for this
|
|
interface, assigned by the DHCP server."
|
|
::= { dhcpEthernetInterface 5 }
|
|
|
|
dhcpDHCPServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the DHCP server IP address used to acquire the
|
|
DHCP settings."
|
|
::= { dhcpEthernetInterface 6 }
|
|
|
|
dhcpPrimaryDNSServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the Primary DNS server, assigned by the DHCP server."
|
|
::= { dhcpEthernetInterface 7 }
|
|
|
|
dhcpSecondaryDNSServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the Secondary DNS server, assigned by the DHCP server."
|
|
::= { dhcpEthernetInterface 8 }
|
|
|
|
dhcpTertiaryDNSServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the tertiary DNS server, assigned by the DHCP server."
|
|
::= { dhcpEthernetInterface 9 }
|
|
|
|
-- ********************************************************************************
|
|
-- PPP Interface 1
|
|
-- ********************************************************************************
|
|
intEthernetInterface OBJECT IDENTIFIER ::= { networkInterfaces 2 }
|
|
|
|
intEthernetInterfaceType OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The type of interface. Indicates 'PPP-1'.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { intEthernetInterface 1 }
|
|
|
|
intEthernetInterfaceEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
interfaceDisabled(0),
|
|
interfaceEnabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Disable or enable the internal ethernet interface.
|
|
NOTE: To alter any of the configuration settings for the
|
|
ethernet interface, the following procedure should be used:
|
|
(1) This object should be set to 'interfaceDisabled'
|
|
(2) Make the modifications to other settings
|
|
(3) This object should be set to 'interfaceEnabled'
|
|
(4) Restart the management module
|
|
|
|
Also note that when attempting to enable this interface, the
|
|
remote IP address is verified to be nonzero. If this verification
|
|
fails, an error response will be returned and the internal ethernet
|
|
interface will be left disabled.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { intEthernetInterface 2 }
|
|
|
|
intEthernetInterfaceLocalIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Contains the IP address for the MM side of the internal ethernet link.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { intEthernetInterface 4 }
|
|
|
|
intEthernetInterfaceDataRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enet10Megabit(3),
|
|
enet100Megabit(4),
|
|
autoSpeed(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Specifies the data transfer rate to be used over the ethernet
|
|
interface: 10Mb, 100Mb, or Auto.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { intEthernetInterface 5 }
|
|
|
|
intEthernetInterfaceDuplexSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fullDuplex(1),
|
|
halfDuplex(2),
|
|
autoDuplex(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Specifies the duplex settings for the data transfer rate to be used over
|
|
the ethernet interface: Half, Full, or Auto.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { intEthernetInterface 6 }
|
|
|
|
intEthernetInterfaceLAA OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(17))
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Specifies the locally administered MAC address. The locally administered
|
|
address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This
|
|
value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and
|
|
A - F. This MM subsystem does not allow use of a multicast address. A multicast
|
|
address has the least significant bit of the first byte set to a 1. The first
|
|
byte must, therefore, be an even number.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { intEthernetInterface 7 }
|
|
|
|
intEthernetInterfaceGatewayIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Contains the IP address of the gateway/router for the ethernet
|
|
interface.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { intEthernetInterface 9 }
|
|
|
|
intEthernetInterfaceBIA OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(17))
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Specifies the burned-in MAC (BIA) address.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { intEthernetInterface 10 }
|
|
|
|
intEthernetInterfaceMTU OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Contains the Maximum Transmission Unit (MTU) for the ethernet
|
|
interface
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { intEthernetInterface 13 }
|
|
|
|
intEthernetInterfaceSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Contains the subnet mask for the ethernet interface.
|
|
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { intEthernetInterface 14 }
|
|
-- ********************************************************************************
|
|
-- Standby Ethernet Interface 1
|
|
-- ********************************************************************************
|
|
standbyExtEthernetInterface OBJECT IDENTIFIER ::= { networkInterfaces 3 }
|
|
standbyExtEthernetInterfaceType OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of interface. Indicates 'Ethernet-1'.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { standbyExtEthernetInterface 1 }
|
|
|
|
standbyExtEthernetInterfaceHostName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the 64 byte null terminated DNS host name for this
|
|
interface.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { standbyExtEthernetInterface 3 }
|
|
|
|
standbyExtEthernetInterfaceIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the IP address for the ethernet interface.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { standbyExtEthernetInterface 4 }
|
|
|
|
standbyExtEthernetInterfaceDataRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enet10Megabit(3),
|
|
enet100Megabit(4),
|
|
autoSpeed(5),
|
|
enet1GigabitAuto(6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the data transfer rate to be used over the ethernet
|
|
interface: 10Mb, 100Mb, 1G Auto or Auto.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM.
|
|
|
|
Note that not all AMM hardware supports the 1G Auto speed. If it does not
|
|
and a SET of this value is attempted, it will be rejected with a
|
|
badValue return code.
|
|
|
|
When a user selects the 1G Auto setting, the duplex setting will be forced to
|
|
fullDuplex."
|
|
::= { standbyExtEthernetInterface 5 }
|
|
|
|
standbyExtEthernetInterfaceDuplexSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fullDuplex(1),
|
|
halfDuplex(2),
|
|
autoDuplex(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the duplex settings for the data transfer rate to be used over
|
|
the ethernet interface: Half, Full, or Auto.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM.
|
|
|
|
When a user selects the 1G Auto speed setting, the duplex setting will be forced to
|
|
fullDuplex."
|
|
::= { standbyExtEthernetInterface 6 }
|
|
|
|
standbyExtEthernetInterfaceLAA OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(17))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the locally administered MAC address. The locally administered
|
|
address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF.
|
|
This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F.
|
|
This MM subsystem does not allow use of a multicast address.
|
|
A multicast address has the least significant bit of the first byte set to a 1. The first
|
|
byte must, therefore, be an even number.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM.
|
|
NOTE: Although the locally administered MAC address can be assigned the same value
|
|
for the primary and backup AMM, it is not recommended."
|
|
::= { standbyExtEthernetInterface 7 }
|
|
|
|
standbyExtEthernetInterfaceDhcpEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dhcpDisabled(0),
|
|
dhcpEnabled(1),
|
|
tryDhcpThenTryStatic(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable or enable DHCP on this interface.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { standbyExtEthernetInterface 8 }
|
|
|
|
standbyExtEthernetInterfaceGatewayIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the IP address of the gateway/router for the ethernet
|
|
interface.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { standbyExtEthernetInterface 9 }
|
|
|
|
standbyExtEthernetInterfaceBIA OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(17))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the burned-in MAC (BIA) address.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { standbyExtEthernetInterface 10 }
|
|
|
|
standbyExtEthernetInterfaceMTU OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the Maximum Transmission Unit (MTU) for the ethernet
|
|
interface.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { standbyExtEthernetInterface 13 }
|
|
|
|
standbyExtEthernetInterfaceSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the subnet mask for the ethernet interface.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { standbyExtEthernetInterface 14 }
|
|
|
|
advancedFailover OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
off(0),
|
|
ipnoswap(1),
|
|
ipswap(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User can enable advanced failover.
|
|
off : no standby network interface
|
|
ipswap: Standby network interface, swap IPs during failover
|
|
ipnoswap: Standby network interface, no swap IPs during failover.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { standbyExtEthernetInterface 15 }
|
|
|
|
-- ********************************************************************************
|
|
-- DHCP Server Assigned Settings for standby ethernet interface 1
|
|
-- ********************************************************************************
|
|
|
|
standbyDhcpEthernetInterface OBJECT IDENTIFIER ::= { standbyExtEthernetInterface 16 }
|
|
|
|
standbyDhcpHostName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the 64 byte null terminated DNS host name for this
|
|
interface, assigned by the DHCP server.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { standbyDhcpEthernetInterface 1 }
|
|
|
|
standbyDhcpIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the IP address for the ethernet interface,
|
|
assigned by the DHCP server.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { standbyDhcpEthernetInterface 2 }
|
|
|
|
standbyDhcpGatewayIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the IP address of the gateway/router for the ethernet
|
|
interface, assigned by the DHCP server.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { standbyDhcpEthernetInterface 3 }
|
|
|
|
standbyDhcpSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the Subnet Mask for the ethernet
|
|
interface, assigned by the DHCP server.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { standbyDhcpEthernetInterface 4 }
|
|
|
|
standbyDhcpDomainName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the 64 byte null terminated Domain Name for this
|
|
interface, assigned by the DHCP server.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { standbyDhcpEthernetInterface 5 }
|
|
|
|
standbyDhcpDHCPServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the DHCP server IP address used to acquire the
|
|
DHCP settings.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { standbyDhcpEthernetInterface 6 }
|
|
|
|
standbyDhcpPrimaryDNSServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the Primary DNS server, assigned by the DHCP server.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { standbyDhcpEthernetInterface 7 }
|
|
|
|
standbyDhcpSecondaryDNSServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the Secondary DNS server, assigned by the DHCP server.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { standbyDhcpEthernetInterface 8 }
|
|
|
|
standbyDhcpTertiaryDNSServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the tertiary DNS server, assigned by the DHCP server.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { standbyDhcpEthernetInterface 9 }
|
|
|
|
-- ********************************************************************************
|
|
-- Ethernet Interface IPv6
|
|
-- ********************************************************************************
|
|
extEthernetInterfaceIPv6 OBJECT IDENTIFIER ::= { networkInterfaces 4 }
|
|
|
|
extEthernetInterfaceIPv6Type OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of interface. Indicates 'Ethernet-1'."
|
|
::= { extEthernetInterfaceIPv6 1 }
|
|
|
|
extEthernetInterfaceIPv6Enabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current IPv6 enabled or disabled state of this AMM.
|
|
|
|
NOTE: If IPv6 address(es) have been configured for one or more
|
|
interfaces/protocols/services on this AMM, when you update
|
|
the firmware to a level which does not support IPv6, all IPv6
|
|
connectivity will be lost, and services/interfaces for which an IPv6
|
|
address was configured may not function properly. You will be required
|
|
to reconfigure these services/interfaces."
|
|
::= { extEthernetInterfaceIPv6 2 }
|
|
|
|
extEthernetInterfaceIPv6Config OBJECT IDENTIFIER ::= { extEthernetInterfaceIPv6 5 }
|
|
|
|
extEthernetInterfaceIPv6LocalAddress OBJECT IDENTIFIER ::= { extEthernetInterfaceIPv6Config 1 }
|
|
|
|
extEthernetInterfaceIPv6LinkLocalAddress OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPv6 link local IP address for the ethernet interface.
|
|
|
|
NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this
|
|
object has the value '0:0:0:0:0:0:0:0'."
|
|
::= { extEthernetInterfaceIPv6LocalAddress 1 }
|
|
|
|
extEthernetInterfaceIPv6StaticIPConfig OBJECT IDENTIFIER ::= { extEthernetInterfaceIPv6Config 2 }
|
|
|
|
extEthernetInterfaceIPv6StaticIPConfigEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPv6 static IP address enabled or disabled state for the ethernet interface."
|
|
::= { extEthernetInterfaceIPv6StaticIPConfig 1 }
|
|
|
|
extEthernetInterfaceIPv6StaticIPAddress OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPv6 static IP address for the ethernet interface.
|
|
|
|
NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this
|
|
object has the value '0:0:0:0:0:0:0:0'."
|
|
::= { extEthernetInterfaceIPv6StaticIPConfig 2 }
|
|
|
|
extEthernetInterfaceIPv6StaticIPAddressPrefixLen OBJECT-TYPE
|
|
SYNTAX INTEGER (1..128)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPv6 static IP address prefix length for the ethernet interface.
|
|
|
|
NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this
|
|
object has the value 0."
|
|
::= { extEthernetInterfaceIPv6StaticIPConfig 3 }
|
|
|
|
extEthernetInterfaceIPv6StaticIPDefaultRoute OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPv6 static IP address default route for the ethernet interface.
|
|
|
|
NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this
|
|
object has the value '0:0:0:0:0:0:0:0'."
|
|
::= { extEthernetInterfaceIPv6StaticIPConfig 4 }
|
|
|
|
extEthernetInterfaceIPv6AutoIPConfig OBJECT IDENTIFIER ::= { extEthernetInterfaceIPv6Config 3 }
|
|
|
|
extEthernetInterfaceIPv6AutoIPConfigEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPv6 automatic IP configuration enabled or disabled state for the ethernet interface.
|
|
|
|
NOTE: extEthernetInterfaceIPv6AutoIPConfigEnabled is the logical OR of extEthernetInterfaceDHCPv6Enabled
|
|
and extEthernetInterfaceIPv6StatelessAutoConfigEnabled settings.
|
|
NOTE: Enabling/Disabling extEthernetInterfaceIPv6AutoIPConfigEnabled will cause both
|
|
extEthernetInterfaceDHCPv6Enabled and extEthernetInterfaceIPv6StatelessAutoConfigEnabled to be enabled/disabled.
|
|
NOTE: extEthernetInterfaceIPv6StaticIPConfigEnabled and extEthernetInterfaceIPv6AutoIPConfigEnabled
|
|
cannot be disabled at the same time."
|
|
::= { extEthernetInterfaceIPv6AutoIPConfig 1 }
|
|
|
|
extEthernetInterfaceDHCPv6Config OBJECT IDENTIFIER ::= { extEthernetInterfaceIPv6AutoIPConfig 2 }
|
|
|
|
extEthernetInterfaceDHCPv6Enabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The DHCPv6 enabled or disabled state for the ethernet interface.
|
|
|
|
NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled is currently disabled, Disabling
|
|
extEthernetInterfaceDHCPv6Enabled will cause extEthernetInterfaceIPv6AutoIPConfigEnabled to be disabled.
|
|
NOTE: If extEthernetInterfaceIPv6StaticIPConfigEnabled and
|
|
extEthernetInterfaceIPv6StatelessAutoConfigEnabled are currently disabled, Disabling
|
|
extEthernetInterfaceDHCPv6Enabled will not be allowed."
|
|
::= { extEthernetInterfaceDHCPv6Config 1 }
|
|
|
|
extEthernetInterfaceDHCPv6IPAddress OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPv6 address for the ethernet interface, assigned by DHCPv6 server.
|
|
|
|
NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled
|
|
is disabled or if DHCPv6 server is not available, this object has the value
|
|
'0:0:0:0:0:0:0:0'."
|
|
::= { extEthernetInterfaceDHCPv6Config 2 }
|
|
|
|
extEthernetInterfaceDHCPv6DomainName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The 64 byte Domain Name for the ethernet interface,
|
|
assigned by the DHCPv6 server.
|
|
|
|
NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled
|
|
is disabled or if DHCPv6 server is not available, this object has the
|
|
value '(Not available)'."
|
|
::= { extEthernetInterfaceDHCPv6Config 4 }
|
|
|
|
extEthernetInterfaceDHCPv6PrimaryDNSServer OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The primary DNS server, assigned by the DHCPv6 server.
|
|
|
|
NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled
|
|
is disabled or if DHCPv6 server is not available, this object has the
|
|
value '0:0:0:0:0:0:0:0'."
|
|
::= { extEthernetInterfaceDHCPv6Config 5 }
|
|
|
|
extEthernetInterfaceDHCPv6SecondaryDNSServer OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The secondary DNS server, assigned by the DHCPv6 server.
|
|
|
|
NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled
|
|
is disabled or if DHCPv6 server is not available, this object has the
|
|
value '0:0:0:0:0:0:0:0'."
|
|
::= { extEthernetInterfaceDHCPv6Config 6 }
|
|
|
|
extEthernetInterfaceDHCPv6TertiaryDNSServer OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The tertiary DNS server, assigned by the DHCPv6 server.
|
|
|
|
NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled
|
|
is disabled or if DHCPv6 server is not available, this object has the
|
|
value '0:0:0:0:0:0:0:0'."
|
|
::= { extEthernetInterfaceDHCPv6Config 7 }
|
|
|
|
extEthernetInterfaceDHCPv6Server OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The DHCPv6 server IPv6 address used to acquire the DHCP settings.
|
|
|
|
NOTE: If extEthernetInterfaceIPv6Enabled or extEthernetInterfaceDHCPv6Enabled
|
|
is disabled or if DHCPv6 server is not available, this object has the
|
|
value '0:0:0:0:0:0:0:0'."
|
|
::= { extEthernetInterfaceDHCPv6Config 8 }
|
|
|
|
extEthernetInterfaceIPv6StatelessAutoConfig OBJECT IDENTIFIER ::= { extEthernetInterfaceIPv6AutoIPConfig 3 }
|
|
|
|
extEthernetInterfaceIPv6StatelessAutoConfigEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPv6 stateless auto-configuration enabled or disabled state for the ethernet interface.
|
|
|
|
NOTE: If extEthernetfInterfaceDHCPv6Enabled is currently disabled, Disabling
|
|
extEthernetInterfaceIPv6StatelessAutoConfigEnabled will cause extEthernetInterfaceIPv6AutoIPConfigEnabled
|
|
to be disabled."
|
|
::= { extEthernetInterfaceIPv6StatelessAutoConfig 1 }
|
|
|
|
extEthernetInterfaceStatelessAutoConfigAddressesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ExtEthernetInterfaceStatelessAutoConfigAddressesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of stateless Auto-Config addresses entries"
|
|
::= { extEthernetInterfaceIPv6StatelessAutoConfig 2 }
|
|
|
|
extEthernetInterfaceStatelessAutoConfigAddressesEntry OBJECT-TYPE
|
|
SYNTAX ExtEthernetInterfaceStatelessAutoConfigAddressesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Stateless Auto-Config address entries"
|
|
INDEX { extEthernetInterfaceStatelessAutoConfigAddressesIndex }
|
|
::= { extEthernetInterfaceStatelessAutoConfigAddressesTable 1 }
|
|
|
|
ExtEthernetInterfaceStatelessAutoConfigAddressesEntry ::= SEQUENCE {
|
|
extEthernetInterfaceStatelessAutoConfigAddressesIndex INTEGER,
|
|
extEthernetInterfaceStatelessAutoConfigAddresses InetAddressIPv6,
|
|
extEthernetInterfaceStatelessAutoConfigAddressesPrefixLen INTEGER
|
|
}
|
|
|
|
extEthernetInterfaceStatelessAutoConfigAddressesIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for stateless Auto-Config addresses.
|
|
|
|
NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or
|
|
extEthernetInterfaceIPv6Enabled is currently disabled, this
|
|
object will show nothing."
|
|
::= { extEthernetInterfaceStatelessAutoConfigAddressesEntry 1 }
|
|
|
|
extEthernetInterfaceStatelessAutoConfigAddresses OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The stateless Auto-Configuration IPv6 address.
|
|
|
|
NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or
|
|
extEthernetInterfaceIPv6Enabled is currently disabled, this
|
|
object will show nothing."
|
|
::= { extEthernetInterfaceStatelessAutoConfigAddressesEntry 2 }
|
|
|
|
extEthernetInterfaceStatelessAutoConfigAddressesPrefixLen OBJECT-TYPE
|
|
SYNTAX INTEGER (1..128)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The stateless Auto-Configration address prefix length.
|
|
|
|
NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or
|
|
extEthernetInterfaceIPv6Enabled is currently disabled, this
|
|
object will show nothing."
|
|
::= { extEthernetInterfaceStatelessAutoConfigAddressesEntry 3 }
|
|
|
|
standbyExtEthernetInterfaceIPv6 OBJECT IDENTIFIER ::= { networkInterfaces 5 }
|
|
|
|
standbyEthernetInterfaceIPv6LocalAddress OBJECT IDENTIFIER ::= { standbyExtEthernetInterfaceIPv6 1 }
|
|
|
|
standbyEthernetInterfaceIPv6LinkLocalAddress OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPv6 link local IP address for the standby AMM."
|
|
::= { standbyEthernetInterfaceIPv6LocalAddress 1 }
|
|
|
|
standbyEthernetInterfaceIPv6StaticIPConfig OBJECT IDENTIFIER ::= { standbyExtEthernetInterfaceIPv6 2 }
|
|
|
|
standbyEthernetInterfaceIPv6StaticIPConfigEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPv6 static IP address state for the AMM.
|
|
|
|
NOTE: This value may be altered through the
|
|
extEthernetInterfaceIPv6StaticIPConfigEnabled object."
|
|
::= { standbyEthernetInterfaceIPv6StaticIPConfig 1 }
|
|
|
|
standbyEthernetInterfaceIPv6StaticIPAddress OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPv6 static IP address for the standby AMM
|
|
|
|
NOTE: If extEthernetInterfaceIPv6Enabled is currently disabled, this
|
|
object has the value '0:0:0:0:0:0:0:0'."
|
|
::= { standbyEthernetInterfaceIPv6StaticIPConfig 2 }
|
|
|
|
standbyEthernetInterfaceIPv6StaticIPAddressPrefixLen OBJECT-TYPE
|
|
SYNTAX INTEGER (1..128)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPv6 static IP address prefix length for the standyby AMM.
|
|
|
|
NOTE: This value may be altered through the
|
|
extEthernetInterfaceIPv6StaticIPAddressPrefixLen object."
|
|
::= { standbyEthernetInterfaceIPv6StaticIPConfig 3 }
|
|
|
|
standbyEthernetInterfaceIPv6StaticIPDefaultRoute OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPv6 static IP address default route for the standby AMM.
|
|
|
|
NOTE: This value may be altered through the
|
|
extEthernetInterfaceIPv6StaticIPDefaultRoute object."
|
|
::= { standbyEthernetInterfaceIPv6StaticIPConfig 4 }
|
|
|
|
standbyEthernetInterfaceDHCPv6Config OBJECT IDENTIFIER ::= { standbyExtEthernetInterfaceIPv6 3 }
|
|
|
|
standbyEthernetInterfaceDHCPv6Enabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The DHCPv6 enabled or disabled state for the standby AMM.
|
|
|
|
NOTE: This field may be altered through the
|
|
extEthernetInterfaceDHCPv6Enabled object."
|
|
::= { standbyEthernetInterfaceDHCPv6Config 1 }
|
|
|
|
standbyEthernetInterfaceDHCPv6IPAddress OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPv6 address for the standby AMM assigned by DHCPv6 server."
|
|
::= { standbyEthernetInterfaceDHCPv6Config 2 }
|
|
|
|
standbyEthernetInterfaceDHCPv6DomainName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The 64 byte Domain Name for the standby AMM
|
|
assigned by the DHCPv6 server."
|
|
::= { standbyEthernetInterfaceDHCPv6Config 4 }
|
|
|
|
standbyEthernetInterfaceStatelessAutoConfigAddressesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF StandbyEthernetInterfaceStatelessAutoConfigAddressesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of stateless Auto-Config addresses entries.
|
|
|
|
NOTE: If extEthernetInterfaceIPv6StatelessAutoConfigEnabled or
|
|
extEthernetInterfaceIPv6Enabled is currently disabled, this
|
|
table will show nothing."
|
|
::= { standbyExtEthernetInterfaceIPv6 4 }
|
|
|
|
standbyEthernetInterfaceStatelessAutoConfigAddressesEntry OBJECT-TYPE
|
|
SYNTAX StandbyEthernetInterfaceStatelessAutoConfigAddressesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Stateless Auto-Config address entries"
|
|
INDEX { standbyEthernetInterfaceStatelessAutoConfigAddressesIndex }
|
|
::= { standbyEthernetInterfaceStatelessAutoConfigAddressesTable 1 }
|
|
|
|
StandbyEthernetInterfaceStatelessAutoConfigAddressesEntry ::= SEQUENCE {
|
|
standbyEthernetInterfaceStatelessAutoConfigAddressesIndex INTEGER,
|
|
standbyEthernetInterfaceStatelessAutoConfigAddresses InetAddressIPv6,
|
|
standbyEthernetInterfaceStatelessAutoConfigAddressesPrefixLen INTEGER
|
|
}
|
|
|
|
standbyEthernetInterfaceStatelessAutoConfigAddressesIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for stateless Auto-Config addresses."
|
|
::= { standbyEthernetInterfaceStatelessAutoConfigAddressesEntry 1 }
|
|
|
|
standbyEthernetInterfaceStatelessAutoConfigAddresses OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The stateless Auto-Configuration IPv6 address."
|
|
::= { standbyEthernetInterfaceStatelessAutoConfigAddressesEntry 2 }
|
|
|
|
standbyEthernetInterfaceStatelessAutoConfigAddressesPrefixLen OBJECT-TYPE
|
|
SYNTAX INTEGER (1..128)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The stateless Auto-Configration address prefix length."
|
|
::= { standbyEthernetInterfaceStatelessAutoConfigAddressesEntry 3 }
|
|
|
|
|
|
ddnsStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Dynamic DNS provides the capability for a networked device
|
|
to notify a domain name server to change, in real time, the
|
|
active DNS configuration of its configured hostnames, addresses
|
|
or other information stored in DNS. With Dynamic DNS, host
|
|
computers gain the capability to notify their respective DNS
|
|
server of the IP address they have received from a DHCP server
|
|
or through self-configuration."
|
|
::= { networkInterfaces 10 }
|
|
|
|
hostName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the DNS host name for this system. This object
|
|
provides the exact same function as extEthernetInterfaceHostName"
|
|
::= { networkInterfaces 11 }
|
|
standbyHostName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the DNS host name for the standby. This object
|
|
provides the exact same function as standbyExtEthernetInterfaceHostName
|
|
and is only applicable to systems with a standby MM."
|
|
::= { networkInterfaces 12 }
|
|
|
|
domainName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user assigned DNS domain name."
|
|
::= { networkInterfaces 13 }
|
|
standbyDomainName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user assigned DNS domain name of the standby. This is only
|
|
applicable to systems with a standby MM."
|
|
::= { networkInterfaces 14 }
|
|
|
|
vlanConfigure OBJECT IDENTIFIER ::= { networkInterfaces 20 }
|
|
|
|
vlanGlobalState OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(0), enable(1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object disables or enables the VLAN feature. The
|
|
configuration objects for the VLAN are in the
|
|
table, vlanTable.
|
|
|
|
The default setting for this object is disable(0).
|
|
|
|
IMPORTANT NOTE: Any change to this object will revert
|
|
back to its previous value if the change is not
|
|
committed by setting the object vlanCommitState to
|
|
executeCommit(3) within the number of minutes indicated
|
|
in the object vlanCommitTimeout."
|
|
::= { vlanConfigure 1 }
|
|
|
|
vlanCommitTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is the number of minutes from the last
|
|
VLAN-related object change until any non-committed changes
|
|
will revert back to their previous settings.
|
|
|
|
This means if a user makes a change that disrupts TCP/IP
|
|
access to the CMM, the change will revert back to its
|
|
previous setting after the number of minutes in this
|
|
object. This allows the user to access the CMM again
|
|
if access is lost through an unintended VLAN setting.
|
|
|
|
Once the changes are committed using the object,
|
|
vlanCommitState, setting it to executeCommit(3), the
|
|
changes will be saved in non-volatile memory.
|
|
|
|
The amount of time before uncommitted changes revert back
|
|
to their previous settings starts from the last change made
|
|
to any VLAN-related object. If no other change is made,
|
|
the user has this number of minutes (the number in this
|
|
object) to commit the changes with vlanCommitState before
|
|
the changes will revert back.
|
|
|
|
The default setting for this object is 2 minutes.
|
|
|
|
IMPORTANT NOTE: Any change to this object will revert
|
|
back to its previous value if the change is not
|
|
committed by setting the object vlanCommitState to
|
|
executeCommit(3) within the number of minutes indicated
|
|
in the object vlanCommitTimeout."
|
|
::= { vlanConfigure 2 }
|
|
|
|
vlanCommitState OBJECT-TYPE
|
|
SYNTAX INTEGER { noChangesPending(1), commitNeeded(2), executeCommit(3) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object gives the status of whether there are
|
|
VLAN-related changes pending that need to be committed,
|
|
and allows a user to commit (save) any VLAN changes.
|
|
|
|
If changes are pending, reading this object will give
|
|
a value of commitNeeded(2). If no changes are pending,
|
|
this object will have the value of noChangesPending(1).
|
|
|
|
To save any VLAN-related changes so they do not revert
|
|
back to previous settings, set this object to
|
|
executeCommit(3) whenever this object has a value of
|
|
commitNeeded(2)."
|
|
::= { vlanConfigure 3 }
|
|
|
|
vlanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VlanEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the VLAN configuration objects.
|
|
The default entry has an vlanEntryIndex equal to 1.
|
|
The objects for this default entry are configurable.
|
|
|
|
An additional VLAN entry may be added by setting the
|
|
object, vlanEntryStatus, at vlanEntryIndex=2 to the value
|
|
of createRequest(2) and also setting the object,
|
|
vlanEntryVlanId, at vlanEntryIndex=2 to a valid, unique
|
|
value.
|
|
|
|
IMPORTANT NOTE: Any changes to the object of this table
|
|
will revert back to their previous settings if the
|
|
changes are not committed by setting the object
|
|
vlanCommitState to executeCommit(3) within the number of
|
|
minutes indicated in the object vlanCommitTimeout."
|
|
::= { vlanConfigure 20 }
|
|
|
|
vlanEntry OBJECT-TYPE
|
|
SYNTAX VlanEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"VLAN entries."
|
|
INDEX { vlanEntryIndex }
|
|
::= { vlanTable 1 }
|
|
|
|
|
|
VlanEntry ::= SEQUENCE {
|
|
vlanEntryIndex INTEGER,
|
|
vlanEntryVlanId INTEGER,
|
|
vlanEntryName OCTET STRING,
|
|
vlanEntryStatus EntryStatus,
|
|
vlanEntryState INTEGER,
|
|
vlanEntrySOLAccess INTEGER,
|
|
vlanEntrycKVMAccess INTEGER,
|
|
vlanEntryTagging INTEGER,
|
|
vlanEntryIOModuleAccess INTEGER,
|
|
vlanEntryVlanDefault INTEGER,
|
|
vlanEntryIPv4StaticAddress IpAddress,
|
|
vlanEntryIPv4StaticGateway IpAddress,
|
|
vlanEntryIPv4StaticMask IpAddress,
|
|
vlanEntryIPv4SubnetRoute1 IpAddress,
|
|
vlanEntryIPv4SubnetRouteMask1 IpAddress,
|
|
vlanEntryIPv4SubnetRoute2 IpAddress,
|
|
vlanEntryIPv4SubnetRouteMask2 IpAddress,
|
|
vlanEntryIPv4SubnetRoute3 IpAddress,
|
|
vlanEntryIPv4SubnetRouteMask3 IpAddress
|
|
}
|
|
|
|
vlanEntryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for VLAN entry. If vlanEntryIndex is equal to 1,
|
|
it is the Default VLAN entry and cannot be deleted."
|
|
::= { vlanEntry 1 }
|
|
|
|
vlanEntryVlanId OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4094)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Valid VLAN ID. Allowed values are 1..4094. If the entry
|
|
is not valid, this object will have the value of 0.
|
|
|
|
If this entry has the vlanEntryIndex value of 1 (default
|
|
VLAN entry), then setting this object will take effect
|
|
immediately. For other entries, when this object is set,
|
|
this entry must have the object, vlanEntryState set to
|
|
enable(1) or restart(2) for this change to take effect."
|
|
::= { vlanEntry 2 }
|
|
|
|
vlanEntryName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..31))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object allows the user to configure a text string
|
|
name for this VLAN entry. This entry name is only used
|
|
as a label for this entry."
|
|
::= { vlanEntry 3 }
|
|
|
|
vlanEntryStatus OBJECT-TYPE
|
|
SYNTAX EntryStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object manages the creation and deletion of this
|
|
entry.
|
|
The steps recommended to add a new VLAN entry are:
|
|
1. Create a new entry in this table
|
|
vlanEntryStatus = createRequest
|
|
2. Set vlanEntryVlanId as required.
|
|
Then the entry will be valid.
|
|
|
|
valid(1) - Indicates that this entry is available
|
|
for use.
|
|
|
|
createRequest(2) - A new entry will be created in this
|
|
table and will transition to the
|
|
vlanEntryStatus value of
|
|
underCreation(3).
|
|
|
|
underCreation(3) - Indicates that this entry exists in the
|
|
agent but is unavailable for use. After
|
|
completing the create operation, the
|
|
agent will set this object to the value
|
|
underCreation(3).
|
|
|
|
invalid(4) - Deletes this entry.
|
|
|
|
The entry with the vlanEntryIndex value of 1 (default VLAN
|
|
entry) cannot be deleted."
|
|
::= { vlanEntry 4 }
|
|
|
|
vlanEntryState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1),
|
|
restart(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object indicates whether this VLAN entry is enabled
|
|
or disabled and allows the user to disable, enable or
|
|
restart this entry except for the exceptions noted below.
|
|
|
|
The entry with a vlanEntryIndex value of 1 (default VLAN
|
|
entry) will always have this object set to enable(1) and
|
|
cannot be set to any other value. Other table entries do
|
|
not have this restriction.
|
|
|
|
Some other objects in this table may not take effect after
|
|
a change until either this object is: set to enable(1) if
|
|
this object currently has the value of disable(0), or set
|
|
to restart(2) if this object currently has the value of
|
|
enable(1). The other objects in this table that require
|
|
this object be set to enable(1) or restart(2) after a
|
|
change are noted in the description for those objects."
|
|
::= { vlanEntry 5 }
|
|
|
|
vlanEntrySOLAccess OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(0), enable(1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object allows the user to set whether the VLAN
|
|
for this entry will have access to the Serial Over
|
|
LAN (SOL) interface.
|
|
|
|
Only one VLAN entry may have this object set to enable(1).
|
|
|
|
By default, the entry with the vlanEntryIndex value of 1
|
|
(default VLAN entry) will have this object set to
|
|
enable(1).
|
|
|
|
To set this object to enable(1) on another entry, this
|
|
object must first be set to disable(0) on any entry
|
|
that has this object set to enable(1)."
|
|
::= { vlanEntry 6 }
|
|
|
|
vlanEntrycKVMAccess OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(0), enable(1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object allows the user to set whether the VLAN
|
|
for this entry will have access to the installed cards
|
|
for concurrent keyboard, video, and mouse (cKVM).
|
|
|
|
Only one VLAN entry may have this object set to enable(1).
|
|
|
|
By default, the entry with the vlanEntryIndex value of 1
|
|
(default VLAN entry) will have this object set to
|
|
enable(1).
|
|
|
|
To set this object to enable(1) on another entry, this
|
|
object must first be set to disable(0) on any entry
|
|
that has this object set to enable(1)."
|
|
::= { vlanEntry 7 }
|
|
|
|
vlanEntryTagging OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(0), enable(1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object allows the user to set whether VLAN tagging
|
|
is enabled for this VLAN entry.
|
|
|
|
This object is only configurable for the entry with the
|
|
vlanEntryIndex value of 1.
|
|
|
|
By default, the entry with the vlanEntryIndex value of 1
|
|
(default VLAN entry) will have this object set to
|
|
disable(0), all other entries will have this object set to
|
|
enable(1)."
|
|
::= { vlanEntry 8 }
|
|
|
|
vlanEntryIOModuleAccess OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(0), enable(1) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This read-only object indicates whether the VLAN
|
|
for this entry will have access to the IO Modules.
|
|
|
|
Only the VLAN entry with the vlanEntryIndex value of 1
|
|
will report this object with the value of enable(1),
|
|
all other entries will have a value of disable(0)."
|
|
::= { vlanEntry 9 }
|
|
|
|
vlanEntryVlanDefault OBJECT-TYPE
|
|
SYNTAX INTEGER { false(0), true(1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object specifies which vlanTable entry is the
|
|
'default entry'. By default, the entry with the
|
|
vlanEntryIndex value of 1 will have this object set to
|
|
true(1).
|
|
|
|
Only one vlanTable entry can be designated as the VLAN
|
|
default entry. Setting this object to true(1) for an
|
|
entry will make this object false(0) for all other
|
|
vlanTable entries.
|
|
|
|
Only the vlanTable entry with this object set to true(1)
|
|
will allow the vlanEntryTagging object to be configurable
|
|
for this vlanEntryIndex index."
|
|
::= { vlanEntry 10 }
|
|
|
|
vlanEntryIPv4StaticAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object sets the IP address for this VLAN entry.
|
|
|
|
The entry with the vlanEntryIndex value of 1 (default VLAN
|
|
entry) will have this object set to the IP address of the
|
|
ethernet interface. The IP address of the default VLAN
|
|
entry can only change by changing the IP address of the
|
|
ethernet interface.
|
|
|
|
For all other VLAN entries, this object may be set to any
|
|
IP address except the IP address of the ethernet
|
|
interface.
|
|
|
|
For a change of this object to take effect, the object,
|
|
vlanEntryState, must be set to enable(1) if the
|
|
vlanEntryState is currently disable(0), or set to
|
|
restart(2) if the vlanEntryState is currently enable(1)."
|
|
::= { vlanEntry 31 }
|
|
|
|
vlanEntryIPv4StaticGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object sets the IP address for the IP gateway
|
|
for this VLAN entry.
|
|
|
|
The entry with the vlanEntryIndex value of 1 (default VLAN
|
|
entry) will have this object set to the IP gateway for the
|
|
ethernet interface. The IP address of the default VLAN
|
|
entry can only change by changing the IP gateway of the
|
|
ethernet interface.
|
|
|
|
For all other VLAN entries, this object may be set to any
|
|
IP address except the IP address of the ethernet
|
|
interface.
|
|
|
|
For a change of this object to take effect, the object,
|
|
vlanEntryState, must be set to enable(1) if the
|
|
vlanEntryState is currently disable(0), or set to
|
|
restart(2) if the vlanEntryState is currently enable(1)."
|
|
::= { vlanEntry 32 }
|
|
|
|
vlanEntryIPv4StaticMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object sets the subnet mask for this VLAN entry.
|
|
|
|
The entry with the vlanEntryIndex value of 1 (default VLAN
|
|
entry) will have this object set to the subnet mask of the
|
|
ethernet interface. The subnet mask of the default VLAN
|
|
entry can only change by changing the subnet mask of the
|
|
ethernet interface.
|
|
|
|
For all other VLAN entries, this object may be set to any
|
|
valid subnet mask.
|
|
|
|
For a change of this object to take effect, the object,
|
|
vlanEntryState, must be set to enable(1) if the
|
|
vlanEntryState is currently disable(0), or set to
|
|
restart(2) if the vlanEntryState is currently enable(1)."
|
|
::= { vlanEntry 33 }
|
|
|
|
vlanEntryIPv4SubnetRoute1 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object sets the IP address of the subnet route 1 for
|
|
this VLAN entry.
|
|
|
|
The entry with the vlanEntryIndex value of 1 (default VLAN
|
|
entry) will always have this object set to 0.0.0.0.
|
|
|
|
For all other VLAN entries, this object may be set to any
|
|
valid subnet route.
|
|
|
|
For a change of this object to take effect, the object,
|
|
vlanEntryState, must be set to enable(1) if the
|
|
vlanEntryState is currently disable(0), or set to
|
|
restart(2) if the vlanEntryState is currently enable(1)."
|
|
::= { vlanEntry 51 }
|
|
|
|
vlanEntryIPv4SubnetRouteMask1 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object sets the subnet route mask 1 for this VLAN
|
|
entry.
|
|
|
|
The entry with the vlanEntryIndex value of 1 (default VLAN
|
|
entry) will always have this object set to 0.0.0.0.
|
|
|
|
For all other VLAN entries, this object may be set to any
|
|
valid subnet mask.
|
|
|
|
For a change of this object to take effect, the object,
|
|
vlanEntryState, must be set to enable(1) if the
|
|
vlanEntryState is currently disable(0), or set to
|
|
restart(2) if the vlanEntryState is currently enable(1)."
|
|
::= { vlanEntry 52 }
|
|
|
|
|
|
vlanEntryIPv4SubnetRoute2 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object sets the IP address of the subnet route 2 for
|
|
this VLAN entry.
|
|
|
|
The entry with the vlanEntryIndex value of 1 (default VLAN
|
|
entry) will always have this object set to 0.0.0.0.
|
|
|
|
For all other VLAN entries, this object may be set to any
|
|
valid subnet route.
|
|
|
|
For a change of this object to take effect, the object,
|
|
vlanEntryState, must be set to enable(1) if the
|
|
vlanEntryState is currently disable(0), or set to
|
|
restart(2) if the vlanEntryState is currently enable(1)."
|
|
::= { vlanEntry 53 }
|
|
|
|
vlanEntryIPv4SubnetRouteMask2 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object sets the subnet route mask 2 for this VLAN
|
|
entry.
|
|
|
|
The entry with the vlanEntryIndex value of 1 (default VLAN
|
|
entry) will always have this object set to 0.0.0.0.
|
|
|
|
For all other VLAN entries, this object may be set to any
|
|
valid subnet mask.
|
|
|
|
For a change of this object to take effect, the object,
|
|
vlanEntryState, must be set to enable(1) if the
|
|
vlanEntryState is currently disable(0), or set to
|
|
restart(2) if the vlanEntryState is currently enable(1)."
|
|
::= { vlanEntry 54 }
|
|
|
|
|
|
vlanEntryIPv4SubnetRoute3 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object sets the IP address of the subnet route 3 for
|
|
this VLAN entry.
|
|
|
|
The entry with the vlanEntryIndex value of 1 (default VLAN
|
|
entry) will always have this object set to 0.0.0.0.
|
|
|
|
For all other VLAN entries, this object may be set to any
|
|
valid subnet route.
|
|
|
|
For a change of this object to take effect, the object,
|
|
vlanEntryState, must be set to enable(1) if the
|
|
vlanEntryState is currently disable(0), or set to
|
|
restart(2) if the vlanEntryState is currently enable(1)."
|
|
::= { vlanEntry 55 }
|
|
|
|
vlanEntryIPv4SubnetRouteMask3 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object sets the subnet route mask 3 for this VLAN
|
|
entry.
|
|
|
|
The entry with the vlanEntryIndex value of 1 (default VLAN
|
|
entry) will always have this object set to 0.0.0.0.
|
|
|
|
For all other VLAN entries, this object may be set to any
|
|
valid subnet mask.
|
|
|
|
For a change of this object to take effect, the object,
|
|
vlanEntryState, must be set to enable(1) if the
|
|
vlanEntryState is currently disable(0), or set to
|
|
restart(2) if the vlanEntryState is currently enable(1)."
|
|
::= { vlanEntry 56 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- TCP/IP Protocol Configuration
|
|
-- ********************************************************************************
|
|
tcpProtocols OBJECT IDENTIFIER ::= { networkConfiguration 3 }
|
|
|
|
-- ********************************************************************************
|
|
-- SNMP Agent Configuration
|
|
-- ********************************************************************************
|
|
snmpAgentConfig OBJECT IDENTIFIER ::= { tcpProtocols 1 }
|
|
|
|
|
|
snmpSystemContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..48))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A NULL terminated 48 byte string that contains the
|
|
SNMP agent contact name."
|
|
::= { snmpAgentConfig 1 }
|
|
|
|
snmpSystemLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..48))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A NULL terminated 48 byte string that contains the
|
|
SNMP agent location name."
|
|
::= { snmpAgentConfig 2 }
|
|
|
|
snmpSystemAgentTrapsDisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
trapsEnabled(0),
|
|
trapsDisabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable or enable SNMP traps."
|
|
::= { snmpAgentConfig 3 }
|
|
|
|
-- ********************************************************************************
|
|
-- SNMP Agent Community Configuration
|
|
-- ********************************************************************************
|
|
snmpAgentCommunityConfig OBJECT IDENTIFIER ::= { snmpAgentConfig 4 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- SNMP Community Configuration table
|
|
-- ********************************************************************************
|
|
|
|
snmpCommunityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnmpCommunityEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of SNMP Community entries"
|
|
::= { snmpAgentCommunityConfig 1 }
|
|
|
|
snmpCommunityEntry OBJECT-TYPE
|
|
SYNTAX SnmpCommunityEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP community entries"
|
|
INDEX { snmpCommunityEntryIndex }
|
|
::= { snmpCommunityTable 1 }
|
|
|
|
SnmpCommunityEntry ::= SEQUENCE {
|
|
snmpCommunityEntryIndex INTEGER,
|
|
snmpCommunityEntryCommunityName OCTET STRING,
|
|
snmpCommunityEntryCommunityIpAddress1 OCTET STRING,
|
|
snmpCommunityEntryCommunityIpAddress2 OCTET STRING,
|
|
snmpCommunityEntryCommunityIpAddress3 OCTET STRING,
|
|
snmpCommunityEntryCommunityViewType INTEGER,
|
|
snmpCommunityEntryCommunityIpAddress4 OCTET STRING,
|
|
snmpCommunityEntryCommunityIpAddress5 OCTET STRING,
|
|
snmpCommunityEntryCommunityIpAddress6 OCTET STRING,
|
|
snmpCommunityEntryCommunityIpAddress7 OCTET STRING,
|
|
snmpCommunityEntryCommunityIpAddress8 OCTET STRING,
|
|
snmpCommunityEntryCommunityIpAddress9 OCTET STRING,
|
|
snmpCommunityEntryCommunityIpAddress10 OCTET STRING,
|
|
snmpCommunityEntryCommunityIpAddress11 OCTET STRING,
|
|
snmpCommunityEntryCommunityIpAddress12 OCTET STRING
|
|
}
|
|
|
|
|
|
snmpCommunityEntryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for SNMP Agent Community entry."
|
|
::= { snmpCommunityEntry 1 }
|
|
|
|
snmpCommunityEntryCommunityName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..15))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Community entry name."
|
|
::= { snmpCommunityEntry 2 }
|
|
|
|
snmpCommunityEntryCommunityIpAddress1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Community IP address or host name.
|
|
Can either be a dotted decimal IP string (e.g. 9.37.44.2)
|
|
or if DNS is enabled a host name. This field also allows two
|
|
wildard values for read-Traps and write-Read-Traps communities:
|
|
0.0.0.0 - allow any IPv4 address
|
|
0::0 - allow any IPv6 address"
|
|
::= { snmpCommunityEntry 3 }
|
|
|
|
snmpCommunityEntryCommunityIpAddress2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Community IP address or host name.
|
|
Can either be a dotted decimal IP string (e.g. 9.37.44.2)
|
|
or if DNS is enabled a host name. This field also allows two
|
|
wildard values for read-Traps and write-Read-Traps communities:
|
|
0.0.0.0 - allow any IPv4 address
|
|
0::0 - allow any IPv6 address"
|
|
::= { snmpCommunityEntry 4 }
|
|
|
|
snmpCommunityEntryCommunityIpAddress3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Community IP address or host name.
|
|
Can either be a dotted decimal IP string (e.g. 9.37.44.2)
|
|
or if DNS is enabled a host name. This field also allows two
|
|
wildard values for read-Traps and write-Read-Traps communities:
|
|
0.0.0.0 - allow any IPv4 address
|
|
0::0 - allow any IPv6 address"
|
|
::= { snmpCommunityEntry 5 }
|
|
|
|
|
|
snmpCommunityEntryCommunityViewType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
read-Traps(1),
|
|
write-Read-Traps(2),
|
|
traps-Only(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Access Level of the SNMPv1 managers. Note this parameter
|
|
is set for each community. Therefore all three managers
|
|
in the same community have the same access level."
|
|
::= { snmpCommunityEntry 6 }
|
|
|
|
|
|
snmpCommunityEntryCommunityIpAddress4 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Community IP address or host name.
|
|
Can either be a dotted decimal IP string (e.g. 9.37.44.2)
|
|
or if DNS is enabled a host name. This field also allows two
|
|
wildard values for read-Traps and write-Read-Traps communities:
|
|
0.0.0.0 - allow any IPv4 address
|
|
0::0 - allow any IPv6 address"
|
|
::= { snmpCommunityEntry 7 }
|
|
|
|
snmpCommunityEntryCommunityIpAddress5 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Community IP address or host name.
|
|
Can either be a dotted decimal IP string (e.g. 9.37.44.2)
|
|
or if DNS is enabled a host name. This field also allows two
|
|
wildard values for read-Traps and write-Read-Traps communities:
|
|
0.0.0.0 - allow any IPv4 address
|
|
0::0 - allow any IPv6 address"
|
|
::= { snmpCommunityEntry 8 }
|
|
|
|
snmpCommunityEntryCommunityIpAddress6 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Community IP address or host name.
|
|
Can either be a dotted decimal IP string (e.g. 9.37.44.2)
|
|
or if DNS is enabled a host name. This field also allows two
|
|
wildard values for read-Traps and write-Read-Traps communities:
|
|
0.0.0.0 - allow any IPv4 address
|
|
0::0 - allow any IPv6 address"
|
|
::= { snmpCommunityEntry 9 }
|
|
|
|
snmpCommunityEntryCommunityIpAddress7 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Community IP address or host name.
|
|
Can either be a dotted decimal IP string (e.g. 9.37.44.2)
|
|
or if DNS is enabled a host name. This field also allows two
|
|
wildard values for read-Traps and write-Read-Traps communities:
|
|
0.0.0.0 - allow any IPv4 address
|
|
0::0 - allow any IPv6 address"
|
|
::= { snmpCommunityEntry 10 }
|
|
|
|
snmpCommunityEntryCommunityIpAddress8 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Community IP address or host name.
|
|
Can either be a dotted decimal IP string (e.g. 9.37.44.2)
|
|
or if DNS is enabled a host name. This field also allows two
|
|
wildard values for read-Traps and write-Read-Traps communities:
|
|
0.0.0.0 - allow any IPv4 address
|
|
0::0 - allow any IPv6 address"
|
|
::= { snmpCommunityEntry 11 }
|
|
|
|
snmpCommunityEntryCommunityIpAddress9 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Community IP address or host name.
|
|
Can either be a dotted decimal IP string (e.g. 9.37.44.2)
|
|
or if DNS is enabled a host name. This field also allows two
|
|
wildard values for read-Traps and write-Read-Traps communities:
|
|
0.0.0.0 - allow any IPv4 address
|
|
0::0 - allow any IPv6 address"
|
|
::= { snmpCommunityEntry 12 }
|
|
|
|
snmpCommunityEntryCommunityIpAddress10 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Community IP address or host name.
|
|
Can either be a dotted decimal IP string (e.g. 9.37.44.2)
|
|
or if DNS is enabled a host name. This field also allows two
|
|
wildard values for read-Traps and write-Read-Traps communities:
|
|
0.0.0.0 - allow any IPv4 address
|
|
0::0 - allow any IPv6 address"
|
|
::= { snmpCommunityEntry 13 }
|
|
|
|
snmpCommunityEntryCommunityIpAddress11 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Community IP address or host name.
|
|
Can either be a dotted decimal IP string (e.g. 9.37.44.2)
|
|
or if DNS is enabled a host name. This field also allows two
|
|
wildard values for read-Traps and write-Read-Traps communities:
|
|
0.0.0.0 - allow any IPv4 address
|
|
0::0 - allow any IPv6 address"
|
|
::= { snmpCommunityEntry 14 }
|
|
|
|
snmpCommunityEntryCommunityIpAddress12 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Community IP address or host name.
|
|
Can either be a dotted decimal IP string (e.g. 9.37.44.2)
|
|
or if DNS is enabled a host name. This field also allows two
|
|
wildard values for read-Traps and write-Read-Traps communities:
|
|
0.0.0.0 - allow any IPv4 address
|
|
0::0 - allow any IPv6 address"
|
|
::= { snmpCommunityEntry 15 }
|
|
|
|
snmpv1SystemAgentEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable or enable the SNMPv1 agent.
|
|
|
|
NOTE: Restart the management module if this MIB object is changed
|
|
with respect to the value at system bootup time. For example the
|
|
SNMPv1 agent was set to disabled at system bootup time and now
|
|
it is enabled. Then restarting the remote supervisor adaptor is
|
|
required.
|
|
|
|
Also note that when attempting to enable this agent,
|
|
the following are verified:
|
|
(1) Is there a valid system contact
|
|
(2) Is there a valid system name
|
|
(3) Is there at least one valid community name and for that
|
|
community name is there one valid IP address or hostname
|
|
(4) Are all defined community names unique
|
|
|
|
If this verification fails an error response will be returned
|
|
and the SNMPv1 agent will be left disabled."
|
|
::= { snmpAgentConfig 5 }
|
|
|
|
snmpv3SystemAgentEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable or enable the SNMPv3 agent.
|
|
|
|
NOTE: Restart the management module if this MIB object is changed
|
|
with respect to the value at system bootup time. For example the
|
|
SNMPv3 agent was set to disabled at system bootup time and now
|
|
it is enabled. Then restarting the remote supervisor adaptor is
|
|
required.
|
|
|
|
Also note that when attempting to enable this agent,
|
|
the following are verified:
|
|
(1) Is there a valid system contact?
|
|
(2) Is there a valid system name?
|
|
|
|
If this verification fails an error response will be returned
|
|
and the SNMPv3 agent will be left disabled."
|
|
|
|
::= { snmpAgentConfig 6 }
|
|
|
|
-- ********************************************************************************
|
|
-- SNMP Agent User Profile Configuration
|
|
-- ********************************************************************************
|
|
|
|
snmpAgentUserProfileConfig OBJECT IDENTIFIER ::= { snmpAgentConfig 9 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- SNMP User Profile Configuration table
|
|
-- ********************************************************************************
|
|
|
|
snmpUserProfileTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnmpUserProfileEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of SNMPv3 User Profile entries"
|
|
::= { snmpAgentUserProfileConfig 1 }
|
|
|
|
snmpUserProfileEntry OBJECT-TYPE
|
|
SYNTAX SnmpUserProfileEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP User Profile entries"
|
|
INDEX { snmpUserProfileEntryIndex }
|
|
::= { snmpUserProfileTable 1 }
|
|
|
|
SnmpUserProfileEntry ::= SEQUENCE {
|
|
snmpUserProfileEntryIndex INTEGER,
|
|
snmpUserProfileEntryContextName OCTET STRING,
|
|
snmpUserProfileEntryAuthProt INTEGER,
|
|
snmpUserProfileEntryPrivProt INTEGER,
|
|
snmpUserProfileEntryPrivPassword OCTET STRING,
|
|
snmpUserProfileEntryViewType INTEGER,
|
|
snmpUserProfileEntryIpAddress OCTET STRING
|
|
}
|
|
|
|
|
|
snmpUserProfileEntryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for SNMPv3 Agent User Profile entry."
|
|
::= { snmpUserProfileEntry 1 }
|
|
|
|
snmpUserProfileEntryContextName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..31))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMPv3 User Profile entry - Context name
|
|
for users to access MIB objects. Note that context names can be duplicates
|
|
and can be shared among users. Empty context names are allowed. The
|
|
default context name is the empty string."
|
|
::= { snmpUserProfileEntry 3 }
|
|
|
|
snmpUserProfileEntryAuthProt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
md5 (2),
|
|
sha (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMPv3 User Profile entry - Authentication Protocol
|
|
supported by the user."
|
|
::= { snmpUserProfileEntry 4 }
|
|
|
|
snmpUserProfileEntryPrivProt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
des (2),
|
|
aes (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMPv3 User Profile entry - Privacy Protocol
|
|
supported by the user. The Privacy Password must be set
|
|
and the Authentication Protocol must be md5 or sha
|
|
before this field may be set to des or aes."
|
|
::= { snmpUserProfileEntry 6 }
|
|
|
|
snmpUserProfileEntryPrivPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..31))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMPv3 User Profile entry - Privacy password
|
|
for the user.
|
|
|
|
NOTE: Value returned for the GET command is
|
|
meaningless for this MIB object for security reasons."
|
|
::= { snmpUserProfileEntry 7 }
|
|
|
|
snmpUserProfileEntryViewType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
read-Traps(1),
|
|
read-Write-Traps(2),
|
|
traps-Only(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMPv3 User Profile entry - Access level (Get, Set, and
|
|
Traps) of the user. "
|
|
::= { snmpUserProfileEntry 8 }
|
|
|
|
|
|
snmpUserProfileEntryIpAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMPv3 User Profile entry - IP address or host name.
|
|
Can either be a dotted decimal IP string (e.g. 9.37.44.2)
|
|
or if DNS is enabled a host name."
|
|
::= { snmpUserProfileEntry 9 }
|
|
|
|
-- ********************************************************************************
|
|
-- DNS Configuration
|
|
-- ********************************************************************************
|
|
dnsConfig OBJECT IDENTIFIER ::= { tcpProtocols 2 }
|
|
|
|
dnsEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dnsDisabled(0),
|
|
dnsEnabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable or enable the DNS agent.
|
|
|
|
NOTE: To alter any of the configuration settings for the DNS agent,
|
|
the following procedure should be used:
|
|
(1) This object should be set to 'disabled'
|
|
(2) Make the modifications to other settings
|
|
(3) This object should be set to 'enabled'
|
|
(4) Restart the management module
|
|
|
|
Also note that when attempting to enable this agent, it is verified
|
|
that there is at least one valid DNS server IP address. If this
|
|
verification fails, an error response will be returned and the DNS
|
|
agent will be left disabled."
|
|
::= { dnsConfig 1 }
|
|
|
|
dnsServerIPAddress1 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the primary DNS server IP address."
|
|
::= { dnsConfig 2 }
|
|
|
|
dnsServerIPAddress2 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the secondary DNS server IP address."
|
|
::= { dnsConfig 3 }
|
|
|
|
dnsServerIPAddress3 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the tertiary DNS server IP address."
|
|
::= { dnsConfig 4 }
|
|
dnsServerIPv6Address1 OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the primary IPv6 DNS server address."
|
|
::= { dnsConfig 12 }
|
|
|
|
dnsServerIPv6Address2 OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the secondary IPv6 DNS server address."
|
|
::= { dnsConfig 13 }
|
|
|
|
dnsServerIPv6Address3 OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the tertiary IPv6 DNS server address."
|
|
::= { dnsConfig 14 }
|
|
|
|
dnsPriority OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ipv6(1),
|
|
ipv4(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Tells the order host names are resolved. The options are
|
|
to either first resolve with an IPv6 DNS server or to first
|
|
resolve with an IPv6 DNS server."
|
|
::= { dnsConfig 20 }
|
|
|
|
-- ********************************************************************************
|
|
-- SMTP Configuration
|
|
-- ********************************************************************************
|
|
smtpConfig OBJECT IDENTIFIER ::= { tcpProtocols 3 }
|
|
|
|
smtpServerNameOrIPAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A NULL terminated 64 byte string that contains the
|
|
SMTP server host name or IP address (a.b.c.d)."
|
|
::= { smtpConfig 1 }
|
|
|
|
attachmentsToEmailAlerts OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAttachments(0),
|
|
attachServiceInformation(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates if the service information should be attached to
|
|
an email alert."
|
|
::= { smtpConfig 2 }
|
|
|
|
smtpEmailDomain OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A NULL terminated string that contains the
|
|
SMTP email domain. If this field is empty, the AMM IP
|
|
address is used as the domain. However, some SMTP
|
|
servers (e.g. - MS Exchange 2007) do not accept an IP address and
|
|
instead require a domain name. This object can be used to set that
|
|
email domain name."
|
|
::= { smtpConfig 3 }
|
|
|
|
|
|
tcpApplicationConfig OBJECT IDENTIFIER ::= { tcpProtocols 4 }
|
|
telnetInactivityTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Default is 120 seconds. Value of zero is no timeout.
|
|
Max value is any positive 4 bytes value. Note that SSH also uses this
|
|
timeout value to wait before disconnecting inactive SSH connections."
|
|
::= { tcpApplicationConfig 1 }
|
|
|
|
commandModeInactivityTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time in seconds before the (Secure)TCP Command Mode times out.
|
|
Default value of 0 means no timeout. Max value is any positive 4 byte value."
|
|
::= { tcpApplicationConfig 2 }
|
|
|
|
secureCommandModeEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Secure TCP Command Mode number of connections.
|
|
AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode.
|
|
A value of 0 means disabled.
|
|
If no valid server certificate is in place, Secure TCP Command Mode will not be allowed to set to enable.
|
|
|
|
NOTE: System Management Software requires this to be enabled for secure communication to the AMM."
|
|
::= { tcpApplicationConfig 3 }
|
|
|
|
commandModeEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set TCP Command Mode number of connections.
|
|
AMM will provide a max of 20 connections for both Secure TCP Command Mode and TCP Command Mode.
|
|
A value of 0 means disabled.
|
|
NOTE: System Management Software requires this to be enabled for non-secure communication to the AMM."
|
|
::= { tcpApplicationConfig 4 }
|
|
|
|
slpAddrType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
multicast(0),
|
|
broadcast(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set SLP address type to 0 (multicast) or 1 (broadcast). Note that when
|
|
slpAddrType is set to broadcast value then the multicast address set in
|
|
slpMulticastAddr will be ignored."
|
|
::= { tcpApplicationConfig 5 }
|
|
|
|
slpMulticastAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Service Locator Protocol Multicast address"
|
|
::= { tcpApplicationConfig 6 }
|
|
|
|
slpEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable Service Location Protocol.
|
|
|
|
NOTE: Change to Service Location Protocol will take
|
|
effect after the next restart of the MM."
|
|
::= { tcpApplicationConfig 7}
|
|
|
|
telnetEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable telnet.
|
|
NOTE: Change to telnet enable/disable will take effect immediately."
|
|
::= { tcpApplicationConfig 9 }
|
|
|
|
sshEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable SSH."
|
|
::= { tcpApplicationConfig 10 }
|
|
|
|
|
|
sshVersion OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allVersions(0), -- deprecated
|
|
version2Only(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When SSH is enabled, this object allows the user to
|
|
configure whether the SSH server accepts all versions
|
|
of client connections or whether it restricts the
|
|
connectivity to the more secure version 2 only.
|
|
|
|
NOTE: Only SSH version 2 is supported now."
|
|
::= { tcpApplicationConfig 11 }
|
|
|
|
|
|
sslServerEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable SSL Server."
|
|
::= { tcpApplicationConfig 15 }
|
|
|
|
|
|
sslClientEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable SSL Client. If no valid client or server certificate is in place,
|
|
SSL client will not be allowed to set to enable."
|
|
::= { tcpApplicationConfig 16 }
|
|
|
|
|
|
ftpEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable FTP."
|
|
::= { tcpApplicationConfig 17 }
|
|
|
|
|
|
tftpEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable TFTP."
|
|
::= { tcpApplicationConfig 19 }
|
|
|
|
|
|
smashTelnetEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable SMASH CLP (System Management Architecture for
|
|
Server Hardware Command Line Protocol) over Telnet.
|
|
This option is not available on all systems."
|
|
::= { tcpApplicationConfig 20 }
|
|
|
|
|
|
smashSshEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable SMASH CLP (System Management Architecture for
|
|
Server Hardware Command Line Protocol) over SSH. A valid SSH
|
|
server key must be installed before enabling secure SMASH.
|
|
This option is not available on all systems."
|
|
::= { tcpApplicationConfig 21 }
|
|
|
|
|
|
tftpCreateEmptyFile OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This MIB object is no longer a requirement for TFTP and has been deprecated."
|
|
::= { tcpApplicationConfig 22 }
|
|
|
|
ftpTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of time before FTP times out. Default is 300 seconds.
|
|
Value of zero is no timeout. Max value is any positive 4 byte value."
|
|
::= { tcpApplicationConfig 23 }
|
|
|
|
rdEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable Remote Disk.
|
|
|
|
NOTE: Change to Remote Disk will take effect after the
|
|
next restart of the MM."
|
|
::= { tcpApplicationConfig 24 }
|
|
|
|
rdocEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable Remote Disk on Card.
|
|
|
|
NOTE: Change to Remote Disk on Card will take effect
|
|
after the next restart of the MM."
|
|
::= { tcpApplicationConfig 25 }
|
|
|
|
kvmEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable KVM.
|
|
|
|
NOTE: Change to KVM will take effect after the next
|
|
restart of the MM."
|
|
::= { tcpApplicationConfig 26 }
|
|
|
|
-- The SSH Server Configuration Group
|
|
mmSshServerConfig OBJECT IDENTIFIER ::= { tcpApplicationConfig 27 }
|
|
|
|
mmSshServerHostKeyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MmSshServerHostKeyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table that contains per public/private host key
|
|
pair information."
|
|
::= { mmSshServerConfig 1 }
|
|
|
|
mmSshServerHostKeyEntry OBJECT-TYPE
|
|
SYNTAX MmSshServerHostKeyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of information about a particular public/private
|
|
host key pair."
|
|
INDEX { mmSshServerHostKeyIndex }
|
|
::= { mmSshServerHostKeyTable 1 }
|
|
|
|
MmSshServerHostKeyEntry ::= SEQUENCE {
|
|
mmSshServerHostKeyIndex INTEGER,
|
|
mmSshServerHostKeyType INTEGER,
|
|
mmSshServerHostKeySize INTEGER,
|
|
mmSshServerHostKeyFingerprint OCTET STRING
|
|
}
|
|
|
|
mmSshServerHostKeyIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index of the public/private host key pair."
|
|
::= { mmSshServerHostKeyEntry 1 }
|
|
|
|
mmSshServerHostKeyType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sshDss (1),
|
|
sshRsa (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of the public/private host key pair."
|
|
::= { mmSshServerHostKeyEntry 2 }
|
|
|
|
mmSshServerHostKeySize OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bits512 (1),
|
|
bits768 (2),
|
|
bits1024 (3),
|
|
bits2048 (4),
|
|
bits4096 (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the public/private host key pair.
|
|
|
|
NOTE: The AMM supports only the bits2048 value."
|
|
::= { mmSshServerHostKeyEntry 3 }
|
|
|
|
mmSshServerHostKeyFingerprint OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RSA fingerprint of the public part of the host key
|
|
pair. This value can be used with the SSH client to
|
|
verify, on the initial connection, that the Secure Shell
|
|
server responding to the request is the server running
|
|
on the AMM. "
|
|
::= { mmSshServerHostKeyEntry 4 }
|
|
|
|
mmSshServerHostKeyGenerate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Initiate the new Host Keys generation process for the
|
|
AMM SSH Server.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object."
|
|
::= { mmSshServerConfig 2 }
|
|
|
|
mmSshServerHostKeyGenerateProgress OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicate the progress of the key generation process."
|
|
::= { mmSshServerConfig 3 }
|
|
|
|
rpEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable Remote Presence."
|
|
::= { tcpApplicationConfig 28 }
|
|
|
|
-- TCP Port Assignment
|
|
tcpPortAssignmentCfg OBJECT IDENTIFIER ::= { tcpProtocols 5 }
|
|
|
|
tcpPortsRestoreDefault OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset all ports to default value.
|
|
http: 80
|
|
https: 443
|
|
telnet: 23
|
|
ssh: 22
|
|
SNMP agent: 161
|
|
SNMP trap: 162
|
|
TCP Command Mode: 6090
|
|
Secure TCP Command Mode: 6091
|
|
Remote Disk: 1044
|
|
Remote Disk-on-Card: 1045
|
|
Remote KVM: 3900
|
|
FTP: 21
|
|
FTP Data: 20
|
|
TFTP: 69
|
|
SMASH telnet: 50023
|
|
SMASH ssh: 50022
|
|
SLP: 427
|
|
Storage Description Service: 1046
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { tcpPortAssignmentCfg 1 }
|
|
|
|
httpPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number. Default value is 80. Once changed, the URL's have to
|
|
include :port at the end."
|
|
::= { tcpPortAssignmentCfg 2 }
|
|
|
|
httpsPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SSL port number. Default value is 443. Once changed, the URL's have to
|
|
include :port at the end."
|
|
::= { tcpPortAssignmentCfg 3 }
|
|
|
|
telnetPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telnet port number. Default value is 23. Port change will take effect immediately."
|
|
::= { tcpPortAssignmentCfg 4 }
|
|
|
|
sshPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SSH port number. Default value is 22."
|
|
::= { tcpPortAssignmentCfg 5 }
|
|
|
|
snmpAgentPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Agent port number. Default value is 161.
|
|
Changes take effect after several seconds."
|
|
::= { tcpPortAssignmentCfg 6 }
|
|
|
|
snmpTrapsPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Traps port number. Default value is 162.
|
|
Changes take effect after several seconds."
|
|
::= { tcpPortAssignmentCfg 7 }
|
|
|
|
commandModePortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"TCP Command Mode port number. Default value is 6090. Change will take effect immediately."
|
|
::= { tcpPortAssignmentCfg 8 }
|
|
|
|
secureCommandModePortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Secure TCP Command Mode port number. Default value is 6091. Change will take effect immediately."
|
|
::= { tcpPortAssignmentCfg 9 }
|
|
|
|
rdPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Remote Disk port number. Default value is 1044. MM has to be reset for change
|
|
to take effect.
|
|
NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object.
|
|
Attempts to set the port value for this SNMP object are no longer supported and any
|
|
read of the value associated with this object will return the rpPortAssignment
|
|
(Remote Presence) port information."
|
|
::= { tcpPortAssignmentCfg 10 }
|
|
|
|
rdocPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Remote Disk-on-Card port number. Default value is 1045. MM has to be reset for
|
|
change to take effect.
|
|
NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object.
|
|
Attempts to set the port value for this SNMP object are no longer supported and any
|
|
read of the value associated with this object will return the rpPortAssignment
|
|
(Remote Presence) port information."
|
|
::= { tcpPortAssignmentCfg 11 }
|
|
|
|
kvmPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Remote KVM port number. Default value is 3900. MM has to be reset for
|
|
change to take effect.
|
|
NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object.
|
|
Attempts to set the port value for this SNMP object are no longer supported and any
|
|
read of the value associated with this object will return the rpPortAssignment
|
|
(Remote Presence) port information."
|
|
::= { tcpPortAssignmentCfg 12 }
|
|
|
|
ftpPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP port number. Default value is 21. Port change will take effect immediately."
|
|
::= { tcpPortAssignmentCfg 13 }
|
|
|
|
ftpDataPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Data port number. Default value is 20. Port change will take effect immediately."
|
|
::= { tcpPortAssignmentCfg 14 }
|
|
|
|
tftpPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"TFTP port number. Default value is 69."
|
|
::= { tcpPortAssignmentCfg 15 }
|
|
|
|
smashTelnetPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port number for SMASH CLP (System Management Architecture for Server
|
|
Hardware Command Line Protocol) over telnet. Default value is 50023.
|
|
Change will take effect immediately.
|
|
This option is not available on all systems."
|
|
::= { tcpPortAssignmentCfg 17 }
|
|
|
|
smashSshPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port number for SMASH CLP (System Management Architecture for Server
|
|
Hardware Command Line Protocol) over SSH. Default value is 50022.
|
|
This option is not available on all systems."
|
|
::= { tcpPortAssignmentCfg 18 }
|
|
|
|
slpPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Service Location Protocol port number. Default value is 427.
|
|
NOTE: This value is normally required to be 427 to interoperate properly
|
|
with other SLP enabled applications."
|
|
::= { tcpPortAssignmentCfg 19 }
|
|
|
|
sdsPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Storage description service port number. Default value is 1046. MM has to be reset for
|
|
change to take effect.
|
|
NOTE: This mib object is deprecated and has been replaced by the rpPortAssignment object.
|
|
Attempts to set the port value for this SNMP object are no longer supported and any
|
|
read of the value associated with this object will return the rpPortAssignment
|
|
(Remote Presence) port information."
|
|
::= { tcpPortAssignmentCfg 20 }
|
|
|
|
rpPortAssignment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote Presence port. Default value is 3900. This port cannot be disabled since it is
|
|
the single service entry point for all the services provided by AMM RPServ to clients."
|
|
::= { tcpPortAssignmentCfg 21 }
|
|
|
|
|
|
-- LDAP Client Configuration
|
|
ldapClientCfg OBJECT IDENTIFIER ::= { tcpProtocols 6 }
|
|
|
|
ldapServer1NameOrIPAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..256))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A NULL terminated 255 byte string that contains the
|
|
LDAP server host name or IP address (a.b.c.d)."
|
|
::= { ldapClientCfg 1 }
|
|
|
|
ldapServer1PortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"LDAP server port number."
|
|
::= { ldapClientCfg 2 }
|
|
|
|
ldapServer2NameOrIPAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..256))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A NULL terminated 255 byte string that contains the
|
|
LDAP server host name or IP address (a.b.c.d)."
|
|
::= { ldapClientCfg 3 }
|
|
|
|
ldapServer2PortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"LDAP server port number."
|
|
::= { ldapClientCfg 4 }
|
|
|
|
ldapServer3NameOrIPAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..256))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A NULL terminated 255 byte string that contains the
|
|
LDAP server host name or IP address (a.b.c.d)."
|
|
::= { ldapClientCfg 5 }
|
|
|
|
ldapServer3PortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"LDAP server port number."
|
|
::= { ldapClientCfg 6 }
|
|
|
|
ldapRootDN OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..256))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A NULL terminated 255 byte string that contains the
|
|
distinguished Name for root entry of directory tree.
|
|
An example might look like dn=foobar,dn=com."
|
|
::= { ldapClientCfg 7 }
|
|
|
|
ldapUserSearchBaseDN OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"As part of the user authentication process, it is necessary to search
|
|
the LDAP server for one or more attributes associated with a particular
|
|
user. Any search request must specify the base DN for the actual search.
|
|
This field specifies the base DN which should be used to search the User
|
|
directory. This is a NULL terminated 255 byte string.
|
|
An example might look like cn=users,dn=foobar,dn=com. If this
|
|
field is left blank, the Root DN will be used as the search base instead.
|
|
As mentioned, user searches are part of the authentication process. They
|
|
are carried out to retrieve information about the user such as login
|
|
permissions, callback number, and group memberships. For Version 2.0 LDAP
|
|
clients, it is strongly encouraged that this parameter be configured,
|
|
otherwise a search using the root DN may not succeed (as seen on Active
|
|
Directory servers).
|
|
|
|
NOTE: This MIB object is for MM only.
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { ldapClientCfg 8 }
|
|
|
|
ldapGroupFilter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..511))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This filter is used for group authentication. It specifies what group or
|
|
groups that this MM belongs to. If left blank, group authentication is
|
|
disabled. Otherwise, group authentication will be performed against the
|
|
filter. The filter can be a specific group name (e.g. RSAWest), a wildcard (*)
|
|
which matches everything, or a wildcard with a prefix (e.g. RSA*). The default
|
|
filter is RSA*.
|
|
After user authentication, group authentication will take place, whereby an
|
|
attempt will be made to match the group or groups (that the user belongs to)
|
|
to the group filter defined here. If there is no match, the user will not pass
|
|
authentication and will be blocked. If there is a match, the login permissions
|
|
for the user will be retrieved from the matched group(s), unless the user
|
|
already has login permissions assigned directly from the user record retrieved
|
|
from the LDAP server."
|
|
::= { ldapClientCfg 9 }
|
|
|
|
ldapBindingMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
anonymousAuthentication(0),
|
|
clientAuthentication(1),
|
|
userPrincipalName(2),
|
|
strictUserPrincipalName(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"On initial binds to the LDAP server during user authentication, there are
|
|
three options:
|
|
Anonymous authentication: Bind attempt is made without a client DN or password.
|
|
If the bind is successful, a search will be requested in order to find an entry
|
|
on the LDAP server for the user attempting to login. If an entry is found, a
|
|
second attempt to bind will be attempted, this time with the user's DN and
|
|
password. If this succeeds, the user is deemed to have passed the user
|
|
authentication phase. Group authentication is then attempted if it is enabled.
|
|
Client authentication: Bind attempt is made with client DN and password
|
|
specified by this configuration parameter. If the bind is successful, we
|
|
proceed as above.
|
|
User Principal Name (UPN): Bind attempt is made directly with the credentials
|
|
used during the login process. If this succeeds, the user is deemed to have
|
|
passed the user authentication phase. Note that for Active Directory servers,
|
|
the userid can have the form someuser@somedomain or simply someuser.
|
|
Strict UPN: This is the same as UPN above, except that the userid must have
|
|
the form someuser@somedomain. The string entered by the user will be parsed
|
|
for the @ symbol.
|
|
|
|
NOTE: strictUserPrincipalName(3) option is available on MM only."
|
|
::= { ldapClientCfg 10 }
|
|
|
|
ldapClientAuthenticationDN OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The initial bind to the LDAP server during user authentication can be
|
|
performed with anonymous authentication, client based authentication, or UPN.
|
|
The client based option requires a client DN and password as parameters to
|
|
the bind request. The client DN is a NULL terminated 255 byte string.
|
|
These parameters are configured here. Note that the password
|
|
can be left blank."
|
|
::= { ldapClientCfg 11 }
|
|
|
|
ldapClientAuthenticationPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The client authentication password"
|
|
::= { ldapClientCfg 12 }
|
|
|
|
ldapUIDsearchAttribute OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the binding method selected is Anonymous authentication or Client
|
|
authentication, the initial bind to the LDAP server is followed by a search
|
|
request aimed at retrieving specific information about the user, including the
|
|
user's DN, login permissions, and group ownerships. In order to retrieve this
|
|
information, the search request must specify the attribute name used to
|
|
represent userids on that server. Specifically, this name is used as a search
|
|
filter against the login id entered by the user. This attribute name is
|
|
configured here. If this field is left blank, a default of uid is used during
|
|
user authentication.
|
|
For example, on Active Directory servers, the attribute name used for userids
|
|
is often sAMAccoutName.
|
|
When the binding method selected is UPN or Strict UPN, this field defaults
|
|
automatically to userPrincipalName during user authentication if the userid
|
|
entered has the form userid@somedomain."
|
|
::= { ldapClientCfg 13 }
|
|
|
|
ldapGroupSearchAttribute OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the MM Group Filter name is configured, it is necessary to retrieve
|
|
from the LDAP server the list of groups that a particular user belongs to.
|
|
This is required to do group authentication. In order to retrieve this list,
|
|
the search filter sent to the server must specify the attribute name associated
|
|
with groups. This field specifies this attribute name.
|
|
If this field is left blank, the attribute name in the filter will default
|
|
to memberOf."
|
|
::= { ldapClientCfg 14 }
|
|
|
|
ldapLoginPermissionAttribute OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When a user successfully authenticates via a LDAP server, it is necessary
|
|
to retrieve the login permissions for this user. In order to retrieve these
|
|
permissions, the search filter sent to the server must specify the attribute
|
|
name associated with login permissions. This field specifies this attribute
|
|
name."
|
|
::= { ldapClientCfg 15 }
|
|
|
|
ldapUseDNSOrPreConfiguredServers OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
usePreConfiguredLDAPServers (0),
|
|
useDNSToFindLDAPServers (1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The MM contains a Version 2.0 LDAP Client that may be configured to provide
|
|
user authentication through one or more LDAP servers. The LDAP server(s) to be
|
|
used for authentication can be discovered dynamically or manually pre-configured.
|
|
|
|
If the usePreConfiguredLDAPServers option is selected, up to 4 LDAP servers can
|
|
be configured. Simply enter the server's IP address or hostname (assuming DNS
|
|
is enabled). The port number for each server is optional. If left blank,
|
|
the default value of 389 is used for non-secured LDAP connections. For secured
|
|
connections, the default is 636. At least one server must be configured.
|
|
|
|
If the useDNSToFindLDAPServers is selected, the domain name need to be provided.
|
|
For LDAP Authentication Only mode, additional information such as the forest name
|
|
also need to be provided."
|
|
::= { ldapClientCfg 16 }
|
|
|
|
ldapDomainSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
extractSearchDomainFromLoginID (0),
|
|
useOnlyConfiguredSearchDomainBelow (1),
|
|
tryLoginFirstThenConfiguredValue (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The DNS SRV request sent to the DNS server must specify a domain name.
|
|
The LDAP client will determine where to get this domain name based on one
|
|
of the following three options:
|
|
|
|
- extractSearchDomainFromLoginID: With this option, the LDAP client will
|
|
use the domain name in the login id. For example, if the login id is
|
|
joesmith@mycompany.com, the domain name equals mycompany.com. If the domain
|
|
name cannot be extracted, the DNS SRV will fail, causing the user
|
|
authentication to fail automatically.
|
|
|
|
- useOnlyConfiguredSearchDomainBelow: With this option, the LDAP client
|
|
will use the domain name configured in the Search Domain parameter.
|
|
|
|
- tryLoginFirstThenConfiguredValue: With this option, the LDAP client will
|
|
first attempt to extract the domain name from the login id. If this succeeds,
|
|
this domain name will be used in the DNS SRV request. If there is no domain
|
|
name present in the login id, the LDAP client will instead use the configured
|
|
Search Domain parameter as the domain name in the DNS SRV request.
|
|
If nothing is configured, user authentication will fail immediately."
|
|
::= { ldapClientCfg 17 }
|
|
|
|
ldapSearchDomain OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This parameter may be used as the domain name in the DNS SRV request,
|
|
depending on how the Domain Source parameter is configured."
|
|
::= { ldapClientCfg 18 }
|
|
|
|
ldapServiceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The DNS SRV request sent to the DNS server must also specify a service name.
|
|
The configured value will be used for this purpose. If left blank, the default
|
|
value used is 'ldap'. Note that the DNS SRV request must also specify a protocol
|
|
name. This defaults to 'tcp' and is not configurable."
|
|
::= { ldapClientCfg 19 }
|
|
|
|
ldapRBSModelCfg OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
oldPermissionString(0),
|
|
newRBSModel(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"There are two mechanisms to authenticate and authorize users on the AMM when
|
|
using an LDAP-enabled server. The first mechanism (oldPermissionString), also
|
|
known as version 1, uses bitstrings to associate permissions to users and groups.
|
|
Version1 supports Active Directory, Novell eDirectory, and OPenLDAP based
|
|
servers. The second mechanism (newRBSModel), also known as version 2,
|
|
uses a new Role-Based-Security (RBS) model. This mechanism is only available
|
|
for Active Directory servers, and requires the use of a snap-in that runs on any
|
|
windows platform. This snap-in tool allows you to configure roles on an Active
|
|
Directory server of your choice, and to associate users/groups and AMMs to those
|
|
roles. A role identifies the permissions given to users and groups associated with
|
|
that role, and also identifies the targets (e.g. AMM) to which this role is attached.
|
|
The use of bitstrings in version 2 disappears, making the configuration much more
|
|
manageable and user-friendly. Note that if you are not using Active Directory, then
|
|
you should not enable version 2. Also note that before enabling version 2, you should
|
|
already have your roles configured on your Active Directory server. The old version 1
|
|
bitstring model cannot be automatically converted to the new version 2 model. This is
|
|
why you must configure your users and groups before enabling version 2. Once
|
|
enabled, the change takes effect immediately. The default value for this field is
|
|
oldPermissionString."
|
|
::= { ldapClientCfg 20 }
|
|
|
|
|
|
ldapTargetName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When administrator chooses Enhanced Role Based Security authentication model,
|
|
he can associate one AMM with one managed target object in Snap-in (one tool
|
|
to configure LDAP users permission) via one target name. The AMM target name can
|
|
be looked as alias of AMM, administrator can change it according to his
|
|
configuration requirements. This is a string of up to 63 characters (plus the
|
|
null character)"
|
|
::= { ldapClientCfg 21 }
|
|
|
|
ldapAuthCfg OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
authenticationAndAuthorization(0),
|
|
authenticationOnly(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If ldapAuthCfg is set to 0, LDAP server is used to authenticate and authorize
|
|
users. If it is set to 1, LDAP server is only used to authenticate users.
|
|
|
|
Note:LDAP Authentication Only mode is currently supported only in an Active
|
|
Directory environment."
|
|
::= { ldapClientCfg 22 }
|
|
|
|
ldapForestName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"LDAP Forest Name.
|
|
|
|
Note: LDAP Forest Name is only for Active Directory environment."
|
|
::= { ldapClientCfg 23 }
|
|
|
|
ldapDomainName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..256))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A NULL terminated 255 byte string that contains the
|
|
LDAP Domain Name."
|
|
::= { ldapClientCfg 24 }
|
|
|
|
|
|
ldapServer4NameOrIPAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..256))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A NULL terminated 255 byte string that contains the
|
|
LDAP server host name or IP address (a.b.c.d)."
|
|
::= { ldapClientCfg 25 }
|
|
|
|
ldapServer4PortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"LDAP server port number."
|
|
::= { ldapClientCfg 26 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Uplink Check Configuration
|
|
-- ********************************************************************************
|
|
|
|
uplinkCheckConfig OBJECT IDENTIFIER ::= { tcpProtocols 7 }
|
|
|
|
uplinkCheckEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uplinkCheckDisabled(0),
|
|
uplinkCheckEnabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable or enable network uplink checking for physical detection.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { uplinkCheckConfig 1 }
|
|
|
|
uplinkCheckDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Delay, in minutes (1-2880), between discovery of a failed network uplink and
|
|
the subsequent MM failover for physical detection.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { uplinkCheckConfig 2 }
|
|
|
|
logicalUplinkDestination OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Destination IP for MM to check its logical link.
|
|
Specify a non-zero IP Address in order to enable logical uplink checking.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { uplinkCheckConfig 3 }
|
|
|
|
logicalUplinkCheckEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uplinkCheckDisabled(0),
|
|
uplinkCheckEnabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable or enable network uplink checking for logical detection.
|
|
logicalUplinkDestination must be set to a non-zero IP Address before enable
|
|
logical uplink checking.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { uplinkCheckConfig 4 }
|
|
|
|
logicalUplinkCheckDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Delay, in minutes(1-2880), between discovery of a failed network uplink and
|
|
the subsequent MM failover for logical detection.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { uplinkCheckConfig 5 }
|
|
|
|
|
|
physicalUplinkCheckDelayInSecs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Delay, in seconds(10-172800), between discovery of a failed network uplink and
|
|
the subsequent MM failover for physical detection.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { uplinkCheckConfig 6 }
|
|
|
|
|
|
logicalUplinkCheckDelayInSecs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Delay, in seconds(60-172800), between discovery of a failed network uplink and
|
|
the subsequent MM failover for logical detection.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { uplinkCheckConfig 7 }
|
|
|
|
logicalUplinkIPv6Destination OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Destination IP for MM to check its logical link using IPv6.
|
|
Specify a non-zero IP Address in order to enable logical uplink checking.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM.
|
|
NOTE: This MIB object is only applicable if IPv6 is enabled on the MM."
|
|
::= { uplinkCheckConfig 8 }
|
|
|
|
logicalUplinkFailoverPolicy OBJECT-TYPE
|
|
SYNTAX INTEGER { either(1), both(2) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Determines when to failover if both an IPv4 and IPv6 destination
|
|
have been configured.
|
|
|
|
If set to 'either' the system will failover if either of the
|
|
destination's link check fails. If set to 'both' then the IPv4
|
|
and IPv6 link checks must fail before a failover will happen.
|
|
|
|
NOTE: This MIB object is only applicable to systems with a standby MM."
|
|
::= { uplinkCheckConfig 9 }
|
|
|
|
-- ********************************************************************************
|
|
-- NTP Configuration
|
|
-- ********************************************************************************
|
|
ntpConfig OBJECT IDENTIFIER ::= { tcpProtocols 8 }
|
|
|
|
ntpEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable the NTP client. The client will update
|
|
the AMM system clock at the frequency specified."
|
|
::= { ntpConfig 1 }
|
|
|
|
ntpIpAddressHostname OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"NTP server's IP address or hostname if DNS is enabled
|
|
and configured."
|
|
::= { ntpConfig 2 }
|
|
|
|
ntpUpdateFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The frequency in minutes that the NTP service runs.
|
|
The value range is 0 to 45000. If the NTP update frequency
|
|
is set to 0, the AMM clock can only be synchronized with the
|
|
NTP server manually."
|
|
::= { ntpConfig 3 }
|
|
|
|
ntpLastUpdate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date and time that the NTP server last updated
|
|
the system clock."
|
|
::= { ntpConfig 4 }
|
|
|
|
ntpUpdateClock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Update the AMM system clock with the specified NTP server.
|
|
A valid NTP server must be configured first."
|
|
::= { ntpConfig 5 }
|
|
|
|
ntpAuthEntry OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The NTP v3 authentication entry to be used for time sync
|
|
with a secure NTP server. The format of an authentication
|
|
entry is <key index> <key type> <key>. <key index> must
|
|
be an integer between 1 and 65535. <key type> must be
|
|
M. <key> is the actual value of the authentication
|
|
key as configured on the NTP server.
|
|
The GET command returns back data in the format:
|
|
<key index> <key type>
|
|
It does not return the actual key."
|
|
::= { ntpConfig 6 }
|
|
|
|
ntpAuthEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enables/Disables NTP v3 authentication"
|
|
::= { ntpConfig 7 }
|
|
|
|
-- ********************************************************************************
|
|
-- SYSLOG Configuration
|
|
-- ********************************************************************************
|
|
syslogConfig OBJECT IDENTIFIER ::= { tcpProtocols 9 }
|
|
|
|
syslogSevFilterLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
error(0),
|
|
warning(1),
|
|
information(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"syslogSevFilterLevel error/warning/information ."
|
|
::= { syslogConfig 1 }
|
|
|
|
-- ********************************************************************************
|
|
-- syslogCollector Configuration
|
|
-- ********************************************************************************
|
|
syslogCollectorConfig OBJECT IDENTIFIER ::= { syslogConfig 2 }
|
|
|
|
-- ********************************************************************************
|
|
-- Syslog Collector Configuration table
|
|
-- ********************************************************************************
|
|
|
|
syslogCollectorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SyslogCollectorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Syslog Collector entries"
|
|
::= { syslogCollectorConfig 1 }
|
|
|
|
syslogCollectorEntry OBJECT-TYPE
|
|
SYNTAX SyslogCollectorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Syslog Collector entries"
|
|
INDEX { syslogCollectorIndex }
|
|
::= { syslogCollectorTable 1 }
|
|
|
|
|
|
SyslogCollectorEntry ::= SEQUENCE {
|
|
syslogCollectorIndex INTEGER,
|
|
syslogCollectorHostnameOrIpAddress OCTET STRING,
|
|
syslogCollectorPort INTEGER,
|
|
syslogCollectorEnable INTEGER
|
|
}
|
|
|
|
syslogCollectorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for Syslog Collector entry."
|
|
::= { syslogCollectorEntry 1 }
|
|
|
|
syslogCollectorHostnameOrIpAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Syslog Collector IP address or host name."
|
|
::= { syslogCollectorEntry 2 }
|
|
|
|
syslogCollectorPort OBJECT-TYPE
|
|
SYNTAX INTEGER(1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Syslog Collector port number."
|
|
::= { syslogCollectorEntry 3 }
|
|
|
|
syslogCollectorEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Syslog Collector enable/disable."
|
|
::= { syslogCollectorEntry 4 }
|
|
|
|
-- ********************************************************************************
|
|
-- Generate test syslog packet
|
|
-- ********************************************************************************
|
|
syslogTestPacket OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generate a test syslog packet. This will send a test syslog to all configured
|
|
and enabled syslog collectors to assist in validating the configuration.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this
|
|
MIB object."
|
|
::= { syslogConfig 3 }
|
|
|
|
-- ********************************************************************************
|
|
-- SOL (Serial Over LAN) Configuration
|
|
-- ********************************************************************************
|
|
solConfiguration OBJECT IDENTIFIER ::= { configureSP 10 }
|
|
|
|
-- ********************************************************************************
|
|
-- SOL Global Configuration
|
|
-- ********************************************************************************
|
|
solGlobalConfig OBJECT IDENTIFIER ::= { solConfiguration 1 }
|
|
|
|
solEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
solDisabled(0),
|
|
solEnabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable SOL dynamically."
|
|
::= { solGlobalConfig 1 }
|
|
|
|
solVlanId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the virtual LAN ID for the internal management network between the MM and
|
|
the Blade System Management Processors (BSMPs). The range of valid VLAN ID's
|
|
is 3 to 4095."
|
|
::= { solGlobalConfig 2 }
|
|
|
|
solAccumulateTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value specifies how much time in millisecond SOL to buffer data before
|
|
sending the next SOL packet since the last SOL packet was transmitted.
|
|
Valid value from 5 ms to 1275 ms. The value is in 5 ms increment. Value
|
|
is not in 5 ms increment will be truncated to a nearest 5s. Default value
|
|
is 5 ms."
|
|
::= { solGlobalConfig 3 }
|
|
|
|
solCharSendThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value specifies how many characters SOL to buffer before
|
|
sending the next SOL packet since the last SOL packet was transmitted.
|
|
Valid value is from 1 to 255"
|
|
::= { solGlobalConfig 4 }
|
|
|
|
solRetry OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Retry count. Valid value from 0-7. 0 means no retries after packet is transmitted.
|
|
Packet will be dropped if no ACK/NACK received by the time retries expired."
|
|
::= { solGlobalConfig 5 }
|
|
|
|
solRetryInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Retry Interval in 10 ms increment. Sets the time that the SOL will
|
|
wait before the first retry and the time between retries when sending SOL
|
|
packets to the remote blade. Value range is from 0 to 2550 ms in 10 ms
|
|
increment. 0 means retries will be sent back-to-back."
|
|
::= { solGlobalConfig 6 }
|
|
|
|
solExitToCliKeySeq OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the keystroke sequence used to escape out of SOL session and back to CLI
|
|
console. This sequence must have at least one character. The caret symbol (^)
|
|
has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that
|
|
map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage
|
|
return). All occurrences of ^ will be interpreted as part of a Ctrl sequence.
|
|
Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences.
|
|
The default value for this field is '^[(' i.e. ESC followed by (."
|
|
::= { solGlobalConfig 7 }
|
|
|
|
solResetBladeKeySeq OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(0..16))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the keystroke sequence used to reset the blade while in SOL session
|
|
console. This sequence must have at least one character. The caret symbol (^)
|
|
has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that
|
|
map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage
|
|
return). All occurrences of ^ will be interpreted as part of a Ctrl sequence.
|
|
Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences.
|
|
The default value for this field is '^[R^[r^[R' i.e. ESC R ESC r ESC R."
|
|
::= { solGlobalConfig 8 }
|
|
|
|
|
|
-- Blade SOL config
|
|
solBladeConfig OBJECT IDENTIFIER ::= { solConfiguration 2 }
|
|
|
|
|
|
solBladeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SolBladeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SOL Blade configuration table."
|
|
::= { solBladeConfig 1 }
|
|
|
|
solBladeEntry OBJECT-TYPE
|
|
SYNTAX SolBladeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SOL Blade table entry"
|
|
INDEX { solBladeIndex }
|
|
::= { solBladeTable 1 }
|
|
|
|
SolBladeEntry ::= SEQUENCE {
|
|
solBladeIndex INTEGER,
|
|
solBladeName OCTET STRING,
|
|
solBladeEnable INTEGER,
|
|
solBladeIpAddr IpAddress,
|
|
solBladeSessionStatus INTEGER,
|
|
solBladeCapability INTEGER
|
|
}
|
|
|
|
solBladeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SOL Blade table index."
|
|
::= { solBladeEntry 1 }
|
|
|
|
solBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { solBladeEntry 2 }
|
|
|
|
solBladeEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
solBladeDisabled(0),
|
|
solBladeEnabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable or enable a SOL on a blade."
|
|
::= { solBladeEntry 3 }
|
|
|
|
solBladeIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the blade derived from the IP address range for the blade
|
|
system management processors on the blades.
|
|
|
|
NOTE: The IPv6 address for a blade can be view with the
|
|
bladeIPv6AddressTable."
|
|
::= { solBladeEntry 4 }
|
|
|
|
solBladeSessionStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
solSessionNotReady(0),
|
|
solSessionReady(1),
|
|
solSessionActive(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status of a blade SOL session:
|
|
solSessionNotReady: no SOL session connected to the blade.
|
|
solSessionReady: there is an SOL session to the blade.
|
|
solSessionActive: there is an SOL session to the blade and there is a
|
|
client using the SOL session."
|
|
::= { solBladeEntry 5 }
|
|
|
|
solBladeCapability OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notSupport(0),
|
|
support(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Display whether or not the blade support SOL feature."
|
|
::= { solBladeEntry 6 }
|
|
|
|
-- ********************************************************************************
|
|
-- Chassis Internal Network (CIN)
|
|
-- ********************************************************************************
|
|
chassisInternalNetwork OBJECT IDENTIFIER ::= { configureSP 11}
|
|
|
|
-- Maximum number of CIN definitions supported
|
|
cinsSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of Chassis Internal Network (CIN) definitions supported.
|
|
Currently a maximum of 14 CIN definitions can be supported."
|
|
::= { chassisInternalNetwork 1 }
|
|
|
|
-- CIN Global Configuration
|
|
cinGlobalEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cinDisabled(0),
|
|
cinEnabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable Chassis Internal Network (CIN) function dynamically.
|
|
Enabled:
|
|
AMM reads the CIN entries. For each enabled entry,
|
|
- If the CIN VLAN ID is new and does not have a CIN interface
|
|
created yet then create a new CIN interface based on that
|
|
CIN VLAN ID. Use the CIN IP address from the entry to create
|
|
a host route.
|
|
- If the CIN IP address is 0.0.0.0 then start ARP monitoring.
|
|
|
|
Disabled:
|
|
- Stop all ARP monitoring.
|
|
- Delete all host routes.
|
|
- Delete all CIN interfaces."
|
|
::= { chassisInternalNetwork 2 }
|
|
|
|
-- CIN Configuration Table
|
|
cinTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CinEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis Internal Network (CIN) configuration table."
|
|
::= { chassisInternalNetwork 3}
|
|
|
|
cinEntry OBJECT-TYPE
|
|
SYNTAX CinEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis Internal Network (CIN) table entry."
|
|
INDEX { cinIndex }
|
|
::= { cinTable 1 }
|
|
|
|
CinEntry ::= SEQUENCE {
|
|
cinIndex INTEGER,
|
|
cinDefExists INTEGER,
|
|
cinDelete INTEGER,
|
|
cinEnable INTEGER,
|
|
cinId INTEGER,
|
|
cinIpAddress IpAddress,
|
|
cinIpv6Address InetAddressIPv6
|
|
}
|
|
|
|
cinIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis Internal Network (CIN) table index."
|
|
::= { cinEntry 1 }
|
|
|
|
cinDefExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates if a Chassis Internal Network (CIN) definition exists for
|
|
this index or not."
|
|
::= { cinEntry 2 }
|
|
|
|
cinDelete OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Delete Chassis Internal Network (CIN) definition.
|
|
Works like CIN entry disabled. However, the entry is also deleted.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this
|
|
MIB object. Deleting a non-defined entry does nothing."
|
|
::= { cinEntry 3 }
|
|
|
|
cinEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable or enable a Chassis Internal Network (CIN) definition.
|
|
Enabled:
|
|
AMM reads the entry and creates a new CIN interface if the CIN VLAN
|
|
ID is new and does not have a CIN interface created yet, adds host
|
|
route, and monitors communication path. Start ARP monitoring if
|
|
IP is 0.0.0.0.
|
|
|
|
Disabled:
|
|
Delete host route. If this is the last IP address that uses the CIN
|
|
interface,
|
|
- Stop ARP monitoring if IP is 0.0.0.0.
|
|
- Delete the CIN interface if there is no other entry depends on it."
|
|
::= { cinEntry 4 }
|
|
|
|
cinId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the Chassis Internal Network (CIN) Virtual LAN (VLAN) ID for
|
|
the internal management network between the Management Module,
|
|
I/O Module, and the blade OS. The range of valid CIN VLAN IDs is
|
|
3 to 4094 (inclusive). This value cannot be the same as the
|
|
Serial Over LAN (SOL) or Concurrent KVM (cKVM) VLAN ID.
|
|
|
|
NOTE: If creating a new CIN definition, you must define cinId
|
|
before you define cinIpAddress.
|
|
|
|
NOTE: Before changing this value on an existing CIN definition,
|
|
you must first disable the definition."
|
|
::= { cinEntry 5 }
|
|
|
|
cinIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis Internal Network (CIN) IP address.
|
|
|
|
Restrictions:
|
|
- CIN entries cannot have matching IP addresses, with the exception of 0.0.0.0.
|
|
- Multiple IP addresses of 0.0.0.0 with different VLAN IDs are allowed.
|
|
- The IP address cannot be multi-cast.
|
|
- The IP address cannot match the AMM IP address.
|
|
- If the CIN IP address is 0.0.0.0, the blade IP address for CIN which is configured
|
|
in the blade's OS can not be in the same subnet as that of AMM.
|
|
|
|
NOTE: If creating a new CIN definition, you must define cinId
|
|
before you define cinIpAddress.
|
|
|
|
NOTE: Before changing this value on an existing CIN definition,
|
|
you must first disable the definition.
|
|
NOTE: When ipv6 is enable on one interface, this column will
|
|
display all zero IPv4 address"
|
|
::= { cinEntry 6}
|
|
cinIpv6Address OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis Internal Network (CIN) IPv6 address
|
|
|
|
NOTE: When ipv4 is enable on one interface,this column will display
|
|
all zero IPv6 address.
|
|
"
|
|
::= { cinEntry 7}
|
|
|
|
-- CIN Status Table
|
|
|
|
cinStatus OBJECT IDENTIFIER ::= { chassisInternalNetwork 4 }
|
|
|
|
cinStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CinStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Chassis Internal Network (CIN) status entry information."
|
|
::= { cinStatus 1 }
|
|
|
|
cinStatusEntry OBJECT-TYPE
|
|
SYNTAX CinStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis Internal Network (CIN) status table entry."
|
|
INDEX { cinStatusIndex }
|
|
::= { cinStatusTable 1 }
|
|
|
|
CinStatusEntry ::= SEQUENCE {
|
|
cinStatusIndex INTEGER,
|
|
cinStatusString OCTET STRING
|
|
}
|
|
|
|
cinStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Chassis Internal Network (CIN) status log index number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { cinStatusEntry 1 }
|
|
|
|
cinStatusString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status of a Chassis Internal Network (CIN) connection. For example:
|
|
|
|
Index:1 VLANID:4094 IPADDR:192.168.70.100 MAC:01:0A:0B:00:01:01 Type:Learned Status:Operational
|
|
|
|
Index is the status entry number in the status table. Followed by the
|
|
VLAN ID, IP address, and MAC address that the Management Module is
|
|
communicating with on the CIN connection.
|
|
|
|
Type is either 'Configured' or 'Learned'. Learned implies that the
|
|
Management Module dynamically discovered the IP address.
|
|
Configured means that the address was explicitly configured in
|
|
the Management Module.
|
|
|
|
Status can be 'Operational', 'Not Operational', or 'Disabled'.
|
|
|
|
'Operational' means the Management Module can ping the CIN IP address.
|
|
|
|
'Not Operational' means that the Management Module cannot ping the CIN
|
|
IP address. Verify that the blade and I/O Module are configured properly
|
|
and that their configurations are compatible with the Management Module.
|
|
The blade OS also needs to have an IP host route defined
|
|
(e.g. route add -host 192.168.70.100 eth0.4094).
|
|
I/O Modules need to have a VLAN defined containing the blade's and the
|
|
AMM's port. Blade and I/O Modules need to be powered up and operational.
|
|
|
|
'Disabled' means that the CIN configuration has been disabled by a
|
|
Management Module administrator.
|
|
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { cinStatusEntry 2 }
|
|
|
|
-- CIN Port Configuration Table
|
|
|
|
cinPortConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CinPortConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis Internal Network (CIN) configuration table for viewing
|
|
and configuring the protocol port information for a particular CIN entry."
|
|
::= { chassisInternalNetwork 5}
|
|
|
|
cinPortConfigEntry OBJECT-TYPE
|
|
SYNTAX CinPortConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis Internal Network (CIN) entry for viewing and configuring
|
|
the protocol port information for a particular CIN entry."
|
|
INDEX { cinPortConfigCINIndex, cinPortConfigIndex }
|
|
::= { cinPortConfigTable 1 }
|
|
|
|
CinPortConfigEntry ::= SEQUENCE {
|
|
cinPortConfigCINIndex INTEGER,
|
|
cinPortConfigIndex INTEGER,
|
|
cinPortConfigProtocolID INTEGER,
|
|
cinPortConfigExternalPort INTEGER,
|
|
cinPortConfigInternalPort INTEGER,
|
|
cinPortConfigEnable INTEGER,
|
|
cinPortConfigDirection INTEGER
|
|
}
|
|
|
|
cinPortConfigCINIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The identifier for the particular CIN configuration that
|
|
these protocol port definitions are associated with. This object
|
|
is the same as the cinIndex value in the cinTable."
|
|
::= { cinPortConfigEntry 1 }
|
|
|
|
cinPortConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The identifier of a particular CIN protocol port configuration
|
|
for a given CIN configuration as specified by cinPortConfigCINIndex.
|
|
There can be up to 16 unique protocol port definitions per CIN
|
|
configuration."
|
|
::= { cinPortConfigEntry 2 }
|
|
|
|
cinPortConfigProtocolID OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tcp(1),
|
|
udp(2),
|
|
notDefined(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the port protocol definition is for a TCP or UDP port.
|
|
If the value of notDefined(3) is returned, the entry has yet to be configured."
|
|
::= { cinPortConfigEntry 3 }
|
|
|
|
cinPortConfigExternalPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The external port number specified for this port protocol
|
|
definition, ranging from 1 to 65,534."
|
|
::= { cinPortConfigEntry 4 }
|
|
|
|
cinPortConfigInternalPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The internal port number specified for this port protocol
|
|
definition, ranging from 1 to 65,534."
|
|
::= { cinPortConfigEntry 5 }
|
|
|
|
cinPortConfigEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of this port protocol definition."
|
|
::= { cinPortConfigEntry 6 }
|
|
|
|
cinPortConfigDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
incoming(1),
|
|
outgoing(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The traffic direction specified for this port protocol definition."
|
|
::= { cinPortConfigEntry 7 }
|
|
|
|
-- ********************************************************************************
|
|
-- SNMP (Ers) Configuration
|
|
-- ********************************************************************************
|
|
configurationManagement OBJECT IDENTIFIER ::= { configureSP 15 }
|
|
saveConfigurationToChassis OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
compressedFormat(1),
|
|
legacyFormat(2) -- deprecated
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Save the configuration settings from the AMM to the chassis.
|
|
This operation may take several seconds.
|
|
The input values for the SET command when AMM is installed in BladeCenter and
|
|
BladeCenter T are:
|
|
1: Save the configuration settings in compressed(AMM) format.
|
|
2: Save the configuration settings in legacy(MM) format. This option has
|
|
been deprecated.
|
|
other: Invalid.
|
|
|
|
The input values for the SET command when AMM is installed in BladeCenter H and
|
|
BladeCenter HT are:
|
|
1: Save the configuration settings in compressed(AMM) format.
|
|
other: Invalid.
|
|
|
|
NOTE: This MIB object is for AMM only and the value returned for the GET command is meaningless."
|
|
::= { configurationManagement 1 }
|
|
|
|
restoreConfigurationFromChassis OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Restore the configuration settings to the AMM from the BladeCenter chassis.
|
|
NOTE: This MIB object is for AMM only and the value returned for the GET command is meaningless."
|
|
::= { configurationManagement 2 }
|
|
|
|
|
|
autoReadConfigInNewChassis OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The AMM will automatically read configuration settings
|
|
from the midplane every time the AMM is inserted into a
|
|
new chassis.
|
|
NOTE: This MIB object is for AMM only."
|
|
::= { configurationManagement 3 }
|
|
|
|
|
|
-- ************************************************************************
|
|
-- BladeCenter T System Management
|
|
-- ************************************************************************
|
|
|
|
-- ************************************************************************
|
|
|
|
telcoAlarmReq OBJECT IDENTIFIER ::= { telcoManagement 1 }
|
|
|
|
|
|
-- ************************************************************************
|
|
-- BladeCenter T Set A Software Alarm
|
|
-- ************************************************************************
|
|
telcoAlarmSet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Create a software alarm. An input octet string consists of the
|
|
alarm severity level and the alarm description (40 bytes max).
|
|
The following severity levels are valid :
|
|
CRT Critical
|
|
MJR Major
|
|
MNR Minor
|
|
|
|
NOTE 1: The level (e.g. MJR) and alarm description string must
|
|
be separated by a blank, otherwise, a badValue error will be returned.
|
|
|
|
NOTE 2: Value returned for the GET command is meaningless for
|
|
this MIB object.
|
|
|
|
NOTE 3: This MIB object is for BladeCenter T only."
|
|
::= { telcoAlarmReq 1 }
|
|
|
|
|
|
-- ************************************************************************
|
|
-- BladeCenter T Ack an Alarm
|
|
-- ************************************************************************
|
|
telcoAlarmAck OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Acknowledge an alarm. An input octet string consists of the
|
|
alarm key ID expressed as 'mmm:ggg:iii:aaa:sss' where:
|
|
m : Module ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
g : Gen ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
i : GenInfo ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
a : Alarm ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
s : Alarm severity value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
|
|
|
|
NOTE 1: Value returned for the GET command is meaningless for
|
|
this MIB object.
|
|
|
|
NOTE 2: This MIB object is for BladeCenter T only."
|
|
::= { telcoAlarmReq 2 }
|
|
|
|
|
|
-- ************************************************************************
|
|
-- BladeCenter T Clear an Alarm
|
|
-- ************************************************************************
|
|
telcoAlarmClear OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clear an active alarm. An input octet string consists of the
|
|
alarm key ID expressed as 'mmm:ggg:iii:aaa:sss' where:
|
|
m : Module ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
g : Gen ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
i : GenInfo ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
a : Alarm ID value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
s : Alarm severity value of decimal digits(1-255) or
|
|
blank space(s) for leading zero(s)
|
|
|
|
|
|
NOTE1 : Value returned for the GET command is meaningless for
|
|
this MIB object.
|
|
|
|
NOTE 2: This MIB object is for BladeCenter T only."
|
|
::= { telcoAlarmReq 3 }
|
|
|
|
|
|
|
|
-- ************************************************************************
|
|
-- ************************************************************************
|
|
-- BladeCenter HT Hardware Operation Management
|
|
-- ************************************************************************
|
|
|
|
telcoHWManagement OBJECT IDENTIFIER ::= { telcoManagement 3 }
|
|
|
|
-- ********************************************************************************
|
|
-- Telco Alarm Panel Power ON/OFF operation
|
|
-- ********************************************************************************
|
|
|
|
tappowerReq OBJECT IDENTIFIER ::= { telcoHWManagement 1 }
|
|
|
|
tappoweronoff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
poweroff(0),
|
|
poweron(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Telco Alarm Panel power on or power off. If powering off a currently
|
|
powered on Telco Alarm Panel, then all LEDs of this request card will
|
|
be reset to OFF and the Safely Remove LED will be turned ON to indicate
|
|
the card is safe for removal.
|
|
NOTE: This MIB object is for BladeCenter HT only.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { tappowerReq 1}
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Network Clock Power ON/OFF operation
|
|
-- ********************************************************************************
|
|
|
|
ncReq OBJECT IDENTIFIER ::= { telcoHWManagement 2 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Network Clock Cards
|
|
-- ****************************************************************************
|
|
|
|
ncReqTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NcReqEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Table of the Network Clock Module Operations.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { ncReq 1 }
|
|
|
|
ncReqEntry OBJECT-TYPE
|
|
SYNTAX NcReqEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock Module Power ON/OFF entry.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
INDEX { ncReqIndex }
|
|
::= { ncReqTable 1 }
|
|
|
|
NcReqEntry ::= SEQUENCE {
|
|
ncReqIndex INTEGER,
|
|
ncReqBayNumber INTEGER,
|
|
ncReqPoweronoff INTEGER
|
|
}
|
|
|
|
|
|
ncReqIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..128)
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock Module Request index.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { ncReqEntry 1 }
|
|
|
|
ncReqBayNumber OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
networkclock1(1),
|
|
networkclock2(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Network Clock Module Request Bay number.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BladeCenter HT only."
|
|
::= { ncReqEntry 2 }
|
|
|
|
ncReqPoweronoff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
poweroff(0),
|
|
poweron(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Request to power on/off for the specified Network Clock Module.
|
|
For consistent results, view as a table and not as individual entries.
|
|
NOTE: This MIB object is for BladeCenter HT only.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { ncReqEntry 3 }
|
|
|
|
|
|
|
|
-- ************************************************************************
|
|
-- BladeCenter T OEM grouping
|
|
-- ************************************************************************
|
|
|
|
telcoOEM OBJECT IDENTIFIER ::= { telcoManagement 127 }
|
|
|
|
telcoOEMs OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A bitmap of information about the contents of this subtree. The
|
|
bitmap is a variable length string containing a list of 1's and 0's.
|
|
Every bit that is set to 1 has a corresponding subtree entry that
|
|
is supported in firmware, while a 0 means that the subtree entry
|
|
is unavailable.
|
|
|
|
NOTE: This MIB object is for BladeCenter T only."
|
|
::= { telcoOEM 1 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- Restart Control
|
|
-- ********************************************************************************
|
|
|
|
restartSPImmediately OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Restart the MM immediately.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for
|
|
this MIB object."
|
|
::= { restartReset 4 }
|
|
|
|
restartStandbyMM OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Restarts the Standby MM from the Primary MM.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for
|
|
this MIB object.
|
|
|
|
NOTE: This mib object is only applicable to systems with a standby MM."
|
|
::= { restartReset 5}
|
|
|
|
switchOverRedundantMM OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch over to the redundant Management Module.
|
|
The failover will not occur if the standby or primary MM is in flashing mode.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for
|
|
this MIB object.
|
|
|
|
NOTE: This mib object is only applicable to systems with a redundant MM."
|
|
::= { restartReset 7 }
|
|
|
|
resetSPConfigAndRestart OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Will cause all the MM information to be reset to it's
|
|
initial factory defaults (all previous configuration
|
|
information is lost) and the MM will be re-started.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object."
|
|
::= { restartReset 20 }
|
|
|
|
resetSPConfigAndRestartSaveLogs OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Will cause all the MM information to be reset to it's
|
|
initial factory defaults (all previous configuration
|
|
information is lost) and the MM will be re-started. The
|
|
logs will be saved.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object."
|
|
::= { restartReset 21 }
|
|
|
|
-- ********************************************************************************
|
|
-- processorBlade
|
|
-- ********************************************************************************
|
|
--This group of objects provides information specific to blades
|
|
processorBlade OBJECT IDENTIFIER ::= { blades 1 }
|
|
|
|
-- ********************************************************************************
|
|
-- Media and I/O
|
|
-- ********************************************************************************
|
|
bladeMediaTrayBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
managementModule(0),
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allocate the media tray to a blade of a BladeCenter system.
|
|
On a get command, a blade ID of 0x00 means that no blade is
|
|
currently using the device. A set command cannot allocate
|
|
the media tray to the management module.
|
|
|
|
NOTE: A blade cannot be allocated to the media tray if the
|
|
value of OID remoteMediaTraySwitchEnable of the blade is disabled."
|
|
::= { processorBlade 1 }
|
|
|
|
bladeKVMBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
managementModule(0),
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allocate the keyboard, video, and mouse ports (KVM) to a blade
|
|
of a blade runner system. On a get command, a blade ID of 0x00
|
|
means that no blade is currently using the devices. A set
|
|
command cannot allocate the KVM to the management module."
|
|
::= { processorBlade 2 }
|
|
|
|
-- ********************************************************************************
|
|
-- Blade boot sequence
|
|
-- ********************************************************************************
|
|
bladeBootSequenceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeBootSequenceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade boot sequence information. Contains
|
|
the boot sequence information for each blade."
|
|
::= { processorBlade 3 }
|
|
|
|
bladeBootSequenceEntry OBJECT-TYPE
|
|
SYNTAX BladeBootSequenceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Boot sequence entry"
|
|
INDEX { bootSequenceIndex }
|
|
::= { bladeBootSequenceTable 1 }
|
|
|
|
|
|
BladeBootSequenceEntry ::= SEQUENCE {
|
|
bootSequenceIndex INTEGER,
|
|
bootSequenceBladeId INTEGER,
|
|
bootSequenceBladeExists INTEGER,
|
|
bootSequenceBladePowerState INTEGER,
|
|
bootSequenceBladeHealthState INTEGER,
|
|
bootSequenceBladeName OCTET STRING,
|
|
bootSequence1 INTEGER,
|
|
bootSequence2 INTEGER,
|
|
bootSequence3 INTEGER,
|
|
bootSequence4 INTEGER
|
|
}
|
|
|
|
bootSequenceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade boot sequence index."
|
|
::= { bladeBootSequenceEntry 1 }
|
|
|
|
bootSequenceBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeBootSequenceEntry 2 }
|
|
|
|
bootSequenceBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeBootSequenceEntry 3 }
|
|
|
|
bootSequenceBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
standby(3),
|
|
hibernate(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the power state of the blade specified."
|
|
::= { bladeBootSequenceEntry 4 }
|
|
|
|
bootSequenceBladeHealthState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
critical(3),
|
|
kernelMode(4),
|
|
discovering(5),
|
|
commError(6),
|
|
noPower(7),
|
|
flashing(8),
|
|
initFailure(9),
|
|
insufficientPower(10),
|
|
powerDenied(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system health state for the blade.
|
|
|
|
Unknown: Blade is in an undefined state.
|
|
Good: Blade is operating normally.
|
|
Warning: One or more outstanding warnings exist for this blade.
|
|
Critical: One or more outstanding critical events for this blade.
|
|
Kernel Mode: Blade is in kernel mode.
|
|
Discovering: The AMM is currently in the process of discovering this blade.
|
|
Communications Error: The AMM failed to communicate with this blade.
|
|
No Power: No power to the blade's domain.
|
|
Flashing: Flashing in progress.
|
|
Initialization Failure: Blade failed to initialized.
|
|
Insufficient Power: Not enough power is left in the blade's domain to power the blade.
|
|
Power Denied: Power was denied to the blade."
|
|
::= { bladeBootSequenceEntry 5 }
|
|
|
|
bootSequenceBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeBootSequenceEntry 6 }
|
|
|
|
bootSequence1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noneSpecified(0),
|
|
floppy(1),
|
|
cdrom(2),
|
|
hardDrive0(3),
|
|
hardDrive1(4),
|
|
hardDrive2(5),
|
|
hardDrive3(6),
|
|
networkBoot(7),
|
|
iscsi(8),
|
|
iscsiCritical(9),
|
|
hardDrive4(10),
|
|
usbModularFlashDrive(11),
|
|
hypervisor(12),
|
|
uefi(13),
|
|
legacyonly(14),
|
|
notAvailable(255)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The boot device for this blade boot sequence. Note that some types
|
|
of blades don't support floppy disk drive. It is recommended that all
|
|
boot sequence 1,2 3, and 4 be configured starting from boot sequence 1.
|
|
If there is any duplication of the configured boot sequence and the
|
|
current configuration, the two boot sequence will be swapped.
|
|
For an example: the current boot sequence is
|
|
1=HD0, 2=CD, 3=FD, 4=HD1
|
|
If the user wants to configure 1=FD which is a duplication of 3 then the
|
|
new boot sequence will be:
|
|
1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped)
|
|
Not all hard drives are available on all blade configurations.
|
|
The 'Iscsi critical' option has a special meaning: the blade tries to
|
|
find an iscsi boot device and if it does not it keeps trying forever."
|
|
::= { bladeBootSequenceEntry 7 }
|
|
|
|
bootSequence2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noneSpecified(0),
|
|
floppy(1),
|
|
cdrom(2),
|
|
hardDrive0(3),
|
|
hardDrive1(4),
|
|
hardDrive2(5),
|
|
hardDrive3(6),
|
|
networkBoot(7),
|
|
iscsi(8),
|
|
iscsiCritical(9),
|
|
hardDrive4(10),
|
|
usbModularFlashDrive(11),
|
|
hypervisor(12),
|
|
uefi(13),
|
|
legacyonly(14),
|
|
notAvailable(255)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The boot device for this blade boot sequence. Note that some types
|
|
of blades don't support floppy disk drive. It is recommended that all
|
|
boot sequence 1,2 3, and 4 be configured starting from boot sequence 1.
|
|
If there is any duplication of the configured boot sequence and the
|
|
current configuration, the two boot sequence will be swapped.
|
|
For an example: the current boot sequence is
|
|
1=HD0, 2=CD, 3=FD, 4=HD1
|
|
If the user wants to configure 1=FD which is a duplication of 3 then the
|
|
new boot sequence will be:
|
|
1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped)
|
|
Not all hard drives are available on all blade configurations.
|
|
The 'Iscsi critical' option has a special meaning: the blade tries to
|
|
find an iscsi boot device and if it does not it keeps trying forever."
|
|
::= { bladeBootSequenceEntry 8 }
|
|
|
|
bootSequence3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noneSpecified(0),
|
|
floppy(1),
|
|
cdrom(2),
|
|
hardDrive0(3),
|
|
hardDrive1(4),
|
|
hardDrive2(5),
|
|
hardDrive3(6),
|
|
networkBoot(7),
|
|
iscsi(8),
|
|
iscsiCritical(9),
|
|
hardDrive4(10),
|
|
usbModularFlashDrive(11),
|
|
hypervisor(12),
|
|
uefi(13),
|
|
legacyonly(14),
|
|
notAvailable(255)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The boot device for this blade boot sequence. Note that some types
|
|
of blades don't support floppy disk drive. It is recommended that all
|
|
boot sequence 1,2 3, and 4 be configured starting from boot sequence 1.
|
|
If there is any duplication of the configured boot sequence and the
|
|
current configuration, the two boot sequence will be swapped.
|
|
For an example: the current boot sequence is
|
|
1=HD0, 2=CD, 3=FD, 4=HD1
|
|
If the user wants to configure 1=FD which is a duplication of 3 then the
|
|
new boot sequence will be:
|
|
1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped)
|
|
Not all hard drives are available on all blade configurations.
|
|
The 'Iscsi critical' option has a special meaning: the blade tries to
|
|
find an iscsi boot device and if it does not it keeps trying forever."
|
|
::= { bladeBootSequenceEntry 9 }
|
|
|
|
bootSequence4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noneSpecified(0),
|
|
floppy(1),
|
|
cdrom(2),
|
|
hardDrive0(3),
|
|
hardDrive1(4),
|
|
hardDrive2(5),
|
|
hardDrive3(6),
|
|
networkBoot(7),
|
|
iscsi(8),
|
|
iscsiCritical(9),
|
|
hardDrive4(10),
|
|
usbModularFlashDrive(11),
|
|
hypervisor(12),
|
|
uefi(13),
|
|
legacyonly(14),
|
|
notAvailable(255)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The boot device for this blade boot sequence. Note that some types
|
|
of blades don't support floppy disk drive. It is recommended that all
|
|
boot sequence 1,2 3, and 4 be configured starting from boot sequence 1.
|
|
If there is any duplication of the configured boot sequence and the
|
|
current configuration, the two boot sequence will be swapped.
|
|
For an example: the current boot sequence is
|
|
1=HD0, 2=CD, 3=FD, 4=HD1
|
|
If the user wants to configure 1=FD which is a duplication of 3 then the
|
|
new boot sequence will be:
|
|
1=FD, 2=CD, 3=HD0, 4=HD1 (1 and 3 swapped)
|
|
Not all hard drives are available on all blade configurations.
|
|
The 'Iscsi critical' option has a special meaning: the blade tries to
|
|
find an iscsi boot device and if it does not it keeps trying forever."
|
|
::= { bladeBootSequenceEntry 10 }
|
|
|
|
-- ********************************************************************************
|
|
-- Blade local control
|
|
-- ********************************************************************************
|
|
bladeRemoteControl OBJECT IDENTIFIER ::= { processorBlade 4 }
|
|
-- remote blade control
|
|
|
|
bladeRemoteControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeRemoteControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade remote power control information.
|
|
Contains power on/off enablement status for each blade."
|
|
::= { bladeRemoteControl 1 }
|
|
|
|
bladeRemoteControlEntry OBJECT-TYPE
|
|
SYNTAX BladeRemoteControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote power control entry"
|
|
INDEX { remoteControlIndex }
|
|
::= { bladeRemoteControlTable 1 }
|
|
|
|
|
|
BladeRemoteControlEntry ::= SEQUENCE {
|
|
remoteControlIndex INTEGER,
|
|
remoteControlBladeId INTEGER,
|
|
remoteControlBladeExists INTEGER,
|
|
remoteControlBladePowerState INTEGER,
|
|
remoteControlBladeHealthState INTEGER,
|
|
remoteControlBladeName OCTET STRING,
|
|
remotePowerControlEnable INTEGER,
|
|
remoteMediaTrayControlEnable INTEGER,
|
|
remoteKVMControlEnable INTEGER,
|
|
remoteWakeOnLanControlEnable INTEGER,
|
|
remoteMediaTraySwitchEnable INTEGER
|
|
}
|
|
|
|
remoteControlIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade remote power control index."
|
|
::= { bladeRemoteControlEntry 1 }
|
|
|
|
|
|
remoteControlBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeRemoteControlEntry 2 }
|
|
|
|
remoteControlBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeRemoteControlEntry 3 }
|
|
|
|
remoteControlBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
standby(3),
|
|
hibernate(4),
|
|
unknown(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power state for blade.
|
|
0 = off, 1 = on, 3 = standby, 4 = hibernate, 255 = unknown."
|
|
::= { bladeRemoteControlEntry 4 }
|
|
|
|
remoteControlBladeHealthState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
critical(3),
|
|
kernelMode(4),
|
|
discovering(5),
|
|
commError(6),
|
|
noPower(7),
|
|
flashing(8),
|
|
initFailure(9),
|
|
insufficientPower(10),
|
|
powerDenied(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system health state for the blade.
|
|
|
|
Unknown: Blade is in an undefined state.
|
|
Good: Blade is operating normally.
|
|
Warning: One or more outstanding warnings exist for this blade.
|
|
Critical: One or more outstanding critical events for this blade.
|
|
Kernel Mode: Blade is in kernel mode.
|
|
Discovering: The AMM is currently in the process of discovering this blade.
|
|
Communications Error: The AMM failed to communicate with this blade.
|
|
No Power: No power to the blade's domain.
|
|
Flashing: Flashing in progress.
|
|
Initialization Failure: Blade failed to initialized.
|
|
Insufficient Power: Not enough power is left in the blade's domain to power the blade.
|
|
Power Denied: Power was denied to the blade."
|
|
::= { bladeRemoteControlEntry 5 }
|
|
|
|
remoteControlBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeRemoteControlEntry 6 }
|
|
|
|
remotePowerControlEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade remote power control enablement status."
|
|
::= { bladeRemoteControlEntry 7 }
|
|
|
|
remoteMediaTrayControlEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade media tray enablement status."
|
|
::= { bladeRemoteControlEntry 8 }
|
|
|
|
|
|
remoteKVMControlEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade KVM enablement status. Note that some types of blades
|
|
don't support KVM"
|
|
::= { bladeRemoteControlEntry 9 }
|
|
|
|
remoteWakeOnLanControlEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Wake On LAN enablement status.
|
|
If WOL is not supported by the blade, it displays 'notApplicable'
|
|
and WOL can not be enabled or disabled."
|
|
::= { bladeRemoteControlEntry 10 }
|
|
|
|
remoteMediaTraySwitchEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Remote Media Tray Switch enablement status.
|
|
If the remote disk feature is disabled, this OID cannot be set."
|
|
::= { bladeRemoteControlEntry 11 }
|
|
|
|
bladePolicy OBJECT IDENTIFIER ::= { bladeRemoteControl 2}
|
|
-- global blade remote control policy
|
|
|
|
bladePolicyPowerControlEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade remote power control enablement status policy."
|
|
::= { bladePolicy 1 }
|
|
|
|
bladePolicyMediaTrayControlEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade media tray enablement status policy."
|
|
::= { bladePolicy 2 }
|
|
|
|
|
|
bladePolicyKVMControlEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade KVM enablement status policy. Note that some types of blades
|
|
don't support KVM."
|
|
::= { bladePolicy 3 }
|
|
|
|
bladePolicyWakeOnLanControlEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Wake On LAN enablement status policy. The
|
|
notApplicable(255) enumeration is not valid for SET
|
|
operations.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object."
|
|
::= { bladePolicy 4 }
|
|
|
|
bladePolicyMediaTraySwitchEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Remote Media Tray Switch enablement status policy.
|
|
If the remote disk feature is disabled, this OID cannot be set."
|
|
::= { bladePolicy 5 }
|
|
|
|
bladePolicyMultipleRemoteVideoEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade multiple remote video sessions enablement status policy.
|
|
|
|
A maximum users can access the video of the same blade from remote
|
|
console when set to enabled. If it is disabled, only one user can
|
|
access the video from remote control."
|
|
::= { bladePolicy 6 }
|
|
|
|
bladePolicyAutoPowerOn OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
restore(1),
|
|
auto(2),
|
|
manual(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade auto-power on policy.
|
|
- restore: all blades will be powered on which were previously on.
|
|
- auto: all blades will automatically be powered on when power is applied to the chassis.
|
|
- manual: all blades will be left off until manually powered on by the user."
|
|
::= { bladePolicy 7 }
|
|
|
|
bladePolicyDisconnectionMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noDisconnection(0),
|
|
forceDisconnection(1),
|
|
accessRequest(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade disconnection mode.
|
|
- noDisconnection: If the blade is already serving a maximum number of users, the requester can't get connection
|
|
- forcedisconnection: If the blade is already serving a maximum number of users, the requester can disconnect any connected user.
|
|
- accessRequest: If the blade is already serving an user, this one will get an access request from the requester."
|
|
::= { bladePolicy 8 }
|
|
|
|
bladePolicySessionTimeOut OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Client session time out in minutes.
|
|
If there is no remote presence activity, after that time, the session will be closed authomatically."
|
|
::= { bladePolicy 9 }
|
|
|
|
bladePolicyRequestTimeOut OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Client connection request time out in seconds.
|
|
In case of single session mode, if the requested user does not respond within this timeout, the user request will be accepted authomatically."
|
|
::= { bladePolicy 10 }
|
|
|
|
bladePolicyRetryTimeOut OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Client connection retry time out in seconds.
|
|
It is possible that the current blade access is negotiated by other 2 clients. If the third comes it will need to wait and retry to connect after a while."
|
|
::= { bladePolicy 11 }
|
|
|
|
bladePolicySessionLostTimeOut OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Client session lost in minutes.
|
|
Amount of time before session closes due to loss of session, and user may regain control. This may happen if for example the client machine loses a network connection."
|
|
::= { bladePolicy 12 }
|
|
|
|
-- ********************************************************************************
|
|
-- Blade system health state params
|
|
-- ********************************************************************************
|
|
|
|
bladeMonitors OBJECT IDENTIFIER ::= { processorBlade 5 }
|
|
|
|
bladeSystemStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeSystemStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade status information."
|
|
::= { bladeMonitors 1 }
|
|
|
|
bladeSystemStatusEntry OBJECT-TYPE
|
|
SYNTAX BladeSystemStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade system status entry"
|
|
INDEX { bladeStatusIndex }
|
|
::= { bladeSystemStatusTable 1 }
|
|
|
|
|
|
BladeSystemStatusEntry ::= SEQUENCE {
|
|
bladeStatusIndex INTEGER,
|
|
bladeId INTEGER,
|
|
bladeExists INTEGER,
|
|
bladePowerState INTEGER,
|
|
bladeHealthState INTEGER,
|
|
bladeName OCTET STRING,
|
|
bladeRemotePowerEnable INTEGER,
|
|
bladeRemoteMediaTrayEnable INTEGER,
|
|
bladeRemoteKVMEnable INTEGER,
|
|
bladeConnectionType INTEGER,
|
|
bladeOwnsKVM INTEGER,
|
|
bladeOwnsMediaTray INTEGER,
|
|
bladeRemoteWakeOnLanEnable INTEGER,
|
|
bladeServerExpansion INTEGER,
|
|
bladeWidth INTEGER,
|
|
bladeSupportCapacityOnDemand INTEGER, -- deprecated
|
|
bladeServerExpansion2 INTEGER,
|
|
bladecKVMStatus INTEGER,
|
|
bladeConnectionType2 INTEGER,
|
|
bladeConnectionType3 INTEGER,
|
|
bladeConnectionType4 INTEGER,
|
|
bladeConnectionType5 INTEGER,
|
|
bladeHighSpeedConnectionType INTEGER,
|
|
bladeIOCompatibility OCTET STRING,
|
|
bladeInventoryReady INTEGER
|
|
}
|
|
|
|
|
|
bladeStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade system status index."
|
|
::= { bladeSystemStatusEntry 1 }
|
|
|
|
bladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeSystemStatusEntry 2 }
|
|
|
|
bladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeSystemStatusEntry 3 }
|
|
|
|
bladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
standby(3),
|
|
hibernate(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the power state of the blade specified."
|
|
::= { bladeSystemStatusEntry 4 }
|
|
|
|
bladeHealthState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
critical(3),
|
|
kernelMode(4),
|
|
discovering(5),
|
|
commError(6),
|
|
noPower(7),
|
|
flashing(8),
|
|
initFailure(9),
|
|
insufficientPower(10),
|
|
powerDenied(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system health state for the blade.
|
|
|
|
Unknown: Blade is in an undefined state.
|
|
Good: Blade is operating normally.
|
|
Warning: One or more outstanding warnings exist for this blade.
|
|
Critical: One or more outstanding critical events for this blade.
|
|
Kernel Mode: Blade is in kernel mode.
|
|
Discovering: The AMM is currently in the process of discovering this blade.
|
|
Communications Error: The AMM failed to communicate with this blade.
|
|
No Power: No power to the blade's domain.
|
|
Flashing: Flashing in progress.
|
|
Initialization Failure: Blade failed to initialized.
|
|
Insufficient Power: Not enough power is left in the blade's domain to power the blade.
|
|
Power Denied: Power was denied to the blade."
|
|
::= { bladeSystemStatusEntry 5 }
|
|
|
|
bladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeSystemStatusEntry 6 }
|
|
|
|
bladeRemotePowerEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote power state for the blade.
|
|
0x01 indicates enabled."
|
|
::= { bladeSystemStatusEntry 7 }
|
|
|
|
bladeRemoteMediaTrayEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote Media Tray state for the blade.
|
|
0x01 indicates enabled."
|
|
::= { bladeSystemStatusEntry 8 }
|
|
|
|
bladeRemoteKVMEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote keyboard/video/monitor state for the blade.
|
|
0x01 indicates enabled. Note that some types of blades
|
|
don't support KVM"
|
|
::= { bladeSystemStatusEntry 9 }
|
|
|
|
bladeConnectionType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
ethernet(1),
|
|
fiber(2),
|
|
serial(3),
|
|
opticalPassThrough(4),
|
|
infiniband(5),
|
|
iSCSI(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection type of the expansion card number one."
|
|
::= { bladeSystemStatusEntry 10 }
|
|
|
|
bladeOwnsKVM OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the MM owns the KVM.
|
|
0 = false, 1 = true. Note that some types of blades
|
|
don't support KVM"
|
|
::= { bladeSystemStatusEntry 11 }
|
|
|
|
bladeOwnsMediaTray OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade owns the Media Tray.
|
|
0 = false, 1 = true."
|
|
::= { bladeSystemStatusEntry 12 }
|
|
|
|
bladeRemoteWakeOnLanEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote wake on LAN state for the blade.
|
|
0x01 indicates enabled."
|
|
::= { bladeSystemStatusEntry 13 }
|
|
|
|
bladeServerExpansion OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This shows whether this blade has an expansion board attached.
|
|
A yes column indicates that an expansion board is installed for this
|
|
blade."
|
|
::= { bladeSystemStatusEntry 14 }
|
|
|
|
bladeWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The width of the blade including any supplement blade attached to it"
|
|
::= { bladeSystemStatusEntry 15 }
|
|
|
|
bladeSupportCapacityOnDemand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This shows whether this blade support Capacity On Demand.
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { bladeSystemStatusEntry 16 }
|
|
|
|
bladeServerExpansion2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This shows whether this blade has an expansion board attached.
|
|
A yes column indicates that an expansion board is installed for this
|
|
blade."
|
|
::= { bladeSystemStatusEntry 17 }
|
|
|
|
bladecKVMStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent(0),
|
|
notReady(1),
|
|
ready(2),
|
|
active(3),
|
|
disabled(4),
|
|
notAvailable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This shows whether this blade has a concurrent keyboard, video, and
|
|
mouse (cKVM) card installed and the status of cKVM on the blade.
|
|
|
|
Not present: A cKVM card is not installed.
|
|
Not ready: A cKVM card is installed but is not functional.
|
|
Ready: A cKVM card is installed and is functional, with no cKVM session in progress.
|
|
Active: A cKVM card is installed and is functional, with a cKVM session currently in progress.
|
|
Disabled: A cKVM card is not enabled on this blade.
|
|
Not available: A cKVM card is installed but the status is not available."
|
|
::= { bladeSystemStatusEntry 21 }
|
|
|
|
bladeConnectionType2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
ethernet(1),
|
|
fiber(2),
|
|
serial(3),
|
|
opticalPassThrough(4),
|
|
infiniband(5),
|
|
iSCSI(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection type of the expansion card number 2."
|
|
::= { bladeSystemStatusEntry 22 }
|
|
|
|
bladeConnectionType3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
ethernet(1),
|
|
fiber(2),
|
|
serial(3),
|
|
opticalPassThrough(4),
|
|
infiniband(5),
|
|
iSCSI(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection type of the expansion card number 3."
|
|
::= { bladeSystemStatusEntry 23 }
|
|
|
|
bladeConnectionType4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
ethernet(1),
|
|
fiber(2),
|
|
serial(3),
|
|
opticalPassThrough(4),
|
|
infiniband(5),
|
|
iSCSI(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection type of the expansion card number 4."
|
|
::= { bladeSystemStatusEntry 24 }
|
|
|
|
bladeConnectionType5 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
ethernet(1),
|
|
fiber(2),
|
|
serial(3),
|
|
opticalPassThrough(4),
|
|
infiniband(5),
|
|
iSCSI(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection type of the expansion card number 5."
|
|
::= { bladeSystemStatusEntry 25 }
|
|
|
|
bladeHighSpeedConnectionType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
ethernet(1),
|
|
fiber(2),
|
|
serial(3),
|
|
opticalPassThrough(4),
|
|
infiniband(5),
|
|
iSCSI(6),
|
|
infinibandPassThrough(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection type of the high speed expansion card number 1."
|
|
::= { bladeSystemStatusEntry 41 }
|
|
|
|
bladeIOCompatibility OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"I/O compatibility status for the blade.
|
|
|
|
The possible values and their meanings are as follows:
|
|
unknown: This indicates a communication error for the blade.
|
|
ok: This is the normal (good) case where the blade and the
|
|
corresponding I/O modules it is internally wired to have no
|
|
compatibility issues.
|
|
noIOMs: This means there are no I/O modules in any of the
|
|
corresponding I/O module bays this blade is internally wired to.
|
|
attention: This indicates that one or more of the corresponding
|
|
I/O modules are in communication error.
|
|
mismatch: This indicates one of the following cases:
|
|
Fabric types are incompatible
|
|
An unknown I/O module type
|
|
An unknown fabric type on the blade"
|
|
::= { bladeSystemStatusEntry 51 }
|
|
|
|
bladeInventoryReady OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notReady(0),
|
|
ready(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When a blade management controller or the AMM is reset, the
|
|
blade inventory data is refreshed in the AMM database. This includes
|
|
items like IBM VPD (e.g. - serial number, UUID) and MAC address information.
|
|
|
|
Applications need to know when this information has been populated on the AMM
|
|
before they begin to query it using SNMP or other means. This simple flag
|
|
object will return a ready or notReady indication for each blade regarding the
|
|
status of this information.
|
|
|
|
Notes:
|
|
|
|
For blades that are experiencing a 'communication failure' or
|
|
'initialization failure' condition, this object will continue to indicate
|
|
notReady until the condition is resolved. Therefore, any application that
|
|
polls this object should also incorporate a timeout period. As of AMM
|
|
release v5.3, a 10 minute timeout seems to be a minimum suggested polling period."
|
|
::= { bladeSystemStatusEntry 52 }
|
|
|
|
|
|
bladeHealthSummaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeHealthSummaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade health summary information.
|
|
Contains information about the overall blade health status."
|
|
::= { bladeMonitors 2 }
|
|
|
|
bladeHealthSummaryEntry OBJECT-TYPE
|
|
SYNTAX BladeHealthSummaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade health summary entry"
|
|
INDEX { bladeHealthSummaryIndex }
|
|
::= { bladeHealthSummaryTable 1 }
|
|
|
|
|
|
BladeHealthSummaryEntry ::= SEQUENCE {
|
|
bladeHealthSummaryIndex INTEGER,
|
|
bladeHealthSummaryBladeId INTEGER,
|
|
bladeHealthSummarySeverity OCTET STRING,
|
|
bladeHealthSummaryDescription OCTET STRING,
|
|
bladeHealthSummaryDateTime OCTET STRING
|
|
}
|
|
|
|
|
|
bladeHealthSummaryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade health summary index."
|
|
::= { bladeHealthSummaryEntry 1 }
|
|
|
|
bladeHealthSummaryBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeHealthSummaryEntry 2 }
|
|
|
|
bladeHealthSummarySeverity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System health summary severity."
|
|
::= { bladeHealthSummaryEntry 3 }
|
|
|
|
bladeHealthSummaryDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System health summary description."
|
|
::= { bladeHealthSummaryEntry 4 }
|
|
|
|
bladeHealthSummaryDateTime OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System health summary date time."
|
|
::= { bladeHealthSummaryEntry 5 }
|
|
|
|
|
|
bladeTemperaturesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeTemperaturesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade temperatures information."
|
|
::= { bladeMonitors 3 }
|
|
|
|
bladeTemperaturesEntry OBJECT-TYPE
|
|
SYNTAX BladeTemperaturesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade temperatures table entry"
|
|
INDEX { temperatureIndex }
|
|
::= { bladeTemperaturesTable 1 }
|
|
|
|
|
|
BladeTemperaturesEntry ::= SEQUENCE {
|
|
temperatureIndex INTEGER,
|
|
temperatureBladeId INTEGER,
|
|
temperatureBladeExists INTEGER,
|
|
temperatureBladePowerState INTEGER,
|
|
temperatureBladeName OCTET STRING,
|
|
temperatureCPU1 OCTET STRING,
|
|
temperatureCPU2 OCTET STRING,
|
|
temperatureCPU3 OCTET STRING,
|
|
temperatureCPU4 OCTET STRING,
|
|
temperatureDASD1 OCTET STRING,
|
|
bladeSensorTempCapability INTEGER,
|
|
bladeSensor1Temp OCTET STRING,
|
|
bladeSensor2Temp OCTET STRING,
|
|
bladeSensor3Temp OCTET STRING,
|
|
bladeSensor4Temp OCTET STRING,
|
|
bladeSensor5Temp OCTET STRING,
|
|
bladeSensor6Temp OCTET STRING,
|
|
bladeSensor7Temp OCTET STRING,
|
|
bladeSensor8Temp OCTET STRING,
|
|
bladeSensor9Temp OCTET STRING
|
|
}
|
|
|
|
temperatureIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade temperatures table index."
|
|
::= { bladeTemperaturesEntry 1 }
|
|
|
|
|
|
temperatureBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeTemperaturesEntry 2 }
|
|
|
|
temperatureBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeTemperaturesEntry 3 }
|
|
|
|
temperatureBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
standby(3),
|
|
hibernate(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the power state of the blade specified."
|
|
::= { bladeTemperaturesEntry 4 }
|
|
|
|
temperatureBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeTemperaturesEntry 5 }
|
|
|
|
temperatureCPU1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU temperature in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 6 }
|
|
|
|
temperatureCPU2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU temperature in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 7 }
|
|
|
|
temperatureCPU3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU temperature in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 8 }
|
|
|
|
temperatureCPU4 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU temperature in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 9 }
|
|
|
|
temperatureDASD1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade DASD temperature in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 10 }
|
|
|
|
bladeSensorTempCapability OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade is IPMI capable or not."
|
|
::= { bladeTemperaturesEntry 11 }
|
|
|
|
bladeSensor1Temp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature reading for an IPMI blade expressed in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 12 }
|
|
|
|
bladeSensor2Temp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature reading for an IPMI blade expressed in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 13 }
|
|
|
|
bladeSensor3Temp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature reading for an IPMI blade expressed in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 14 }
|
|
|
|
bladeSensor4Temp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature reading for an IPMI blade expressed in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 15 }
|
|
|
|
bladeSensor5Temp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature reading for an IPMI blade expressed in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 16 }
|
|
|
|
bladeSensor6Temp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature reading for an IPMI blade expressed in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 17 }
|
|
|
|
bladeSensor7Temp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature reading for an IPMI blade expressed in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 18 }
|
|
|
|
bladeSensor8Temp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature reading for an IPMI blade expressed in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 19 }
|
|
|
|
bladeSensor9Temp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature reading for an IPMI blade expressed in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperaturesEntry 20 }
|
|
|
|
bladeTemperatureThresholdsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeTemperatureThresholdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade temperature thresholds information."
|
|
::= { bladeMonitors 4 }
|
|
|
|
bladeTemperatureThresholdsEntry OBJECT-TYPE
|
|
SYNTAX BladeTemperatureThresholdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade temperature thresholds table entry"
|
|
INDEX { temperatureThresholdIndex }
|
|
::= { bladeTemperatureThresholdsTable 1 }
|
|
|
|
|
|
BladeTemperatureThresholdsEntry ::= SEQUENCE {
|
|
temperatureThresholdIndex INTEGER,
|
|
temperatureThresholdBladeId INTEGER,
|
|
temperatureThresholdBladeExists INTEGER,
|
|
temperatureThresholdBladePowerState INTEGER,
|
|
temperatureThresholdBladeName OCTET STRING,
|
|
temperatureCPU1HardShutdown OCTET STRING,
|
|
temperatureCPU1Warning OCTET STRING,
|
|
temperatureCPU1WarningReset OCTET STRING,
|
|
temperatureCPU2HardShutdown OCTET STRING,
|
|
temperatureCPU2Warning OCTET STRING,
|
|
temperatureCPU2WarningReset OCTET STRING,
|
|
temperatureCPU3HardShutdown OCTET STRING,
|
|
temperatureCPU3Warning OCTET STRING,
|
|
temperatureCPU3WarningReset OCTET STRING,
|
|
temperatureCPU4HardShutdown OCTET STRING,
|
|
temperatureCPU4Warning OCTET STRING,
|
|
temperatureCPU4WarningReset OCTET STRING,
|
|
temperatureDASD1HardShutdown OCTET STRING,
|
|
temperatureDASD1Warning OCTET STRING,
|
|
temperatureDASD1WarningReset OCTET STRING,
|
|
bladeTempThresholdSensorCapability INTEGER,
|
|
temperatureSensor1HardShutdown OCTET STRING,
|
|
temperatureSensor1Warning OCTET STRING,
|
|
temperatureSensor1WarningReset OCTET STRING,
|
|
temperatureSensor2HardShutdown OCTET STRING,
|
|
temperatureSensor2Warning OCTET STRING,
|
|
temperatureSensor2WarningReset OCTET STRING,
|
|
temperatureSensor3HardShutdown OCTET STRING,
|
|
temperatureSensor3Warning OCTET STRING,
|
|
temperatureSensor3WarningReset OCTET STRING,
|
|
temperatureSensor4HardShutdown OCTET STRING,
|
|
temperatureSensor4Warning OCTET STRING,
|
|
temperatureSensor4WarningReset OCTET STRING,
|
|
temperatureSensor5HardShutdown OCTET STRING,
|
|
temperatureSensor5Warning OCTET STRING,
|
|
temperatureSensor5WarningReset OCTET STRING,
|
|
temperatureSensor6HardShutdown OCTET STRING,
|
|
temperatureSensor6Warning OCTET STRING,
|
|
temperatureSensor6WarningReset OCTET STRING,
|
|
temperatureSensor7HardShutdown OCTET STRING,
|
|
temperatureSensor7Warning OCTET STRING,
|
|
temperatureSensor7WarningReset OCTET STRING,
|
|
temperatureSensor8HardShutdown OCTET STRING,
|
|
temperatureSensor8Warning OCTET STRING,
|
|
temperatureSensor8WarningReset OCTET STRING,
|
|
temperatureSensor9HardShutdown OCTET STRING,
|
|
temperatureSensor9Warning OCTET STRING,
|
|
temperatureSensor9WarningReset OCTET STRING
|
|
}
|
|
|
|
temperatureThresholdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade temperature threshold table index."
|
|
::= { bladeTemperatureThresholdsEntry 1 }
|
|
|
|
|
|
temperatureThresholdBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeTemperatureThresholdsEntry 2 }
|
|
|
|
temperatureThresholdBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeTemperatureThresholdsEntry 3 }
|
|
|
|
temperatureThresholdBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
standby(3),
|
|
hibernate(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the power state of the blade specified."
|
|
::= { bladeTemperatureThresholdsEntry 4 }
|
|
|
|
temperatureThresholdBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeTemperatureThresholdsEntry 5 }
|
|
|
|
temperatureCPU1HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU hard shutdown temperature in degrees
|
|
centigrade(C). If the component's temperature rises above
|
|
this value the system will be powered off immediately.
|
|
If enabled, a critical alert/event will be generated.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 6 }
|
|
|
|
temperatureCPU1Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU warning temperature in degrees centigrade(C).
|
|
If the temperature rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 7 }
|
|
|
|
temperatureCPU1WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU warning reset temperature in degrees
|
|
centigrade(C). If the temperature rises above this value and
|
|
if a warning alert/event had previously been created then the
|
|
alert/event will be reset.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 8 }
|
|
|
|
temperatureCPU2HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU hard shutdown temperature in degrees
|
|
centigrade(C). If the component's temperature rises above
|
|
this value the system will be powered off immediately.
|
|
If enabled, a critical alert/event will be generated.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 9 }
|
|
|
|
temperatureCPU2Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU warning temperature in degrees centigrade(C).
|
|
If the temperature rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 10 }
|
|
|
|
temperatureCPU2WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU warning reset temperature in degrees
|
|
centigrade(C). If the temperature rises above this value and
|
|
if a warning alert/event had previously been created then the
|
|
alert/event will be reset.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 11 }
|
|
|
|
temperatureCPU3HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU hard shutdown temperature in degrees
|
|
centigrade(C). If the component's temperature rises above
|
|
this value the system will be powered off immediately.
|
|
If enabled, a critical alert/event will be generated.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 12 }
|
|
|
|
temperatureCPU3Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU warning temperature in degrees centigrade(C).
|
|
If the temperature rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 13 }
|
|
|
|
temperatureCPU3WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU warning reset temperature in degrees
|
|
centigrade(C). If the temperature rises above this value and
|
|
if a warning alert/event had previously been created then the
|
|
alert/event will be reset.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 14 }
|
|
|
|
temperatureCPU4HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU hard shutdown temperature in degrees
|
|
centigrade(C). If the component's temperature rises above
|
|
this value the system will be powered off immediately.
|
|
If enabled, a critical alert/event will be generated.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 15 }
|
|
|
|
temperatureCPU4Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU warning temperature in degrees centigrade(C).
|
|
If the temperature rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 16 }
|
|
|
|
temperatureCPU4WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade CPU warning reset temperature in degrees
|
|
centigrade(C). If the temperature rises above this value and
|
|
if a warning alert/event had previously been created then the
|
|
alert/event will be reset.
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 17 }
|
|
|
|
temperatureDASD1HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade DASD hard shutdown temperature in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 18 }
|
|
|
|
temperatureDASD1Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade DASD warning temperature in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 19 }
|
|
|
|
temperatureDASD1WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade DASD warning reset temperature in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 20 }
|
|
|
|
bladeTempThresholdSensorCapability OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade is IPMI capable or not."
|
|
::= { bladeTemperatureThresholdsEntry 21 }
|
|
|
|
temperatureSensor1HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 22 }
|
|
|
|
temperatureSensor1Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 23 }
|
|
|
|
temperatureSensor1WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 24 }
|
|
|
|
temperatureSensor2HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 25 }
|
|
|
|
temperatureSensor2Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 26 }
|
|
|
|
temperatureSensor2WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 27 }
|
|
|
|
temperatureSensor3HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 28 }
|
|
|
|
temperatureSensor3Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 29 }
|
|
|
|
temperatureSensor3WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 30 }
|
|
|
|
temperatureSensor4HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 31 }
|
|
|
|
temperatureSensor4Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 32 }
|
|
|
|
temperatureSensor4WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 33 }
|
|
|
|
temperatureSensor5HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 34 }
|
|
|
|
temperatureSensor5Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 35 }
|
|
|
|
temperatureSensor5WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 36 }
|
|
|
|
temperatureSensor6HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 37 }
|
|
|
|
temperatureSensor6Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 38 }
|
|
|
|
temperatureSensor6WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 39 }
|
|
|
|
temperatureSensor7HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 40 }
|
|
|
|
temperatureSensor7Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 41 }
|
|
|
|
temperatureSensor7WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 42 }
|
|
|
|
temperatureSensor8HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 43 }
|
|
|
|
temperatureSensor8Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 44 }
|
|
|
|
temperatureSensor8WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 45 }
|
|
|
|
temperatureSensor9HardShutdown OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 46 }
|
|
|
|
temperatureSensor9Warning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 47 }
|
|
|
|
temperatureSensor9WarningReset OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
|
|
An octet string expressed as 'sddd.dd Centigrade' where:
|
|
s is the sign ('-' for negative or blank space for positive)
|
|
d is a decimal digit or blank space for leading zeroes.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Temperature' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeTemperatureThresholdsEntry 48 }
|
|
|
|
|
|
|
|
bladeVoltagesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeVoltagesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade voltages information."
|
|
::= { bladeMonitors 5 }
|
|
|
|
bladeVoltagesEntry OBJECT-TYPE
|
|
SYNTAX BladeVoltagesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade voltages table entry"
|
|
INDEX { voltageIndex }
|
|
::= { bladeVoltagesTable 1 }
|
|
|
|
BladeVoltagesEntry ::= SEQUENCE {
|
|
voltageIndex INTEGER,
|
|
voltageBladeId INTEGER,
|
|
voltageBladeExists INTEGER,
|
|
voltageBladePowerState INTEGER,
|
|
voltageBladeName OCTET STRING,
|
|
bladePlus5Volt OCTET STRING,
|
|
bladePlus3pt3Volt OCTET STRING,
|
|
bladePlus12Volt OCTET STRING,
|
|
bladePlus2pt5Volt OCTET STRING,
|
|
bladePlus1pt5Volt OCTET STRING,
|
|
bladePlus1pt25Volt OCTET STRING,
|
|
bladeVRM1Volt OCTET STRING,
|
|
bladeSensorVoltCapability INTEGER,
|
|
bladeSensor1Volt OCTET STRING,
|
|
bladeSensor2Volt OCTET STRING,
|
|
bladeSensor3Volt OCTET STRING,
|
|
bladeSensor4Volt OCTET STRING,
|
|
bladeSensor5Volt OCTET STRING,
|
|
bladeSensor6Volt OCTET STRING,
|
|
bladeSensor7Volt OCTET STRING,
|
|
bladeSensor8Volt OCTET STRING,
|
|
bladeSensor9Volt OCTET STRING,
|
|
bladeSensor10Volt OCTET STRING,
|
|
bladeSensor11Volt OCTET STRING,
|
|
bladeSensor12Volt OCTET STRING,
|
|
bladeSensor13Volt OCTET STRING,
|
|
bladeSensor14Volt OCTET STRING,
|
|
bladeSensor15Volt OCTET STRING,
|
|
bladeSensor16Volt OCTET STRING,
|
|
bladeSensor17Volt OCTET STRING,
|
|
bladeSensor18Volt OCTET STRING,
|
|
bladeSensor19Volt OCTET STRING,
|
|
bladeSensor20Volt OCTET STRING,
|
|
bladeSensor21Volt OCTET STRING,
|
|
bladeSensor22Volt OCTET STRING,
|
|
bladeSensor23Volt OCTET STRING,
|
|
bladeSensor24Volt OCTET STRING,
|
|
bladeSensor25Volt OCTET STRING,
|
|
bladeSensor26Volt OCTET STRING,
|
|
bladeSensor27Volt OCTET STRING,
|
|
bladeSensor28Volt OCTET STRING,
|
|
bladeSensor29Volt OCTET STRING,
|
|
bladeSensor30Volt OCTET STRING
|
|
}
|
|
|
|
voltageIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade voltages table index."
|
|
::= { bladeVoltagesEntry 1 }
|
|
|
|
|
|
voltageBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeVoltagesEntry 2 }
|
|
|
|
voltageBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeVoltagesEntry 3 }
|
|
|
|
voltageBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
standby(3),
|
|
hibernate(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the power state of the blade specified."
|
|
::= { bladeVoltagesEntry 4 }
|
|
|
|
voltageBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeVoltagesEntry 5 }
|
|
|
|
bladePlus5Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+5 Volt power supply voltage reading for the blade
|
|
expressed in Volts(V). An octet string expressed as
|
|
'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 6 }
|
|
|
|
bladePlus3pt3Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+3.3 Volt power supply voltage reading for the blade
|
|
expressed in Volts(V). An octet string expressed as
|
|
'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 7 }
|
|
|
|
bladePlus12Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+12 Volt power supply voltage reading for the blade
|
|
expressed in Volts(V). An octet string expressed as
|
|
'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 8 }
|
|
|
|
bladePlus2pt5Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+2.5 Volt power supply voltage reading for the blade
|
|
expressed in Volts(V). An octet string expressed as
|
|
'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 10 }
|
|
|
|
bladePlus1pt5Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+1.5 Volt power supply voltage reading for the blade
|
|
expressed in Volts(V). An octet string expressed as
|
|
'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 11 }
|
|
|
|
bladePlus1pt25Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"+1.25 Volt power supply voltage reading for the blade
|
|
expressed in Volts(V). An octet string expressed as
|
|
'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 12 }
|
|
|
|
bladeVRM1Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"VRM 1 voltage reading for the blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 13 }
|
|
|
|
bladeSensorVoltCapability OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade is IPMI capable or not."
|
|
::= { bladeVoltagesEntry 14 }
|
|
|
|
bladeSensor1Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 15 }
|
|
|
|
bladeSensor2Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 16 }
|
|
|
|
bladeSensor3Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 17 }
|
|
|
|
bladeSensor4Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 18 }
|
|
|
|
bladeSensor5Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 19 }
|
|
|
|
bladeSensor6Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 20 }
|
|
|
|
bladeSensor7Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 21 }
|
|
|
|
bladeSensor8Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 22 }
|
|
|
|
bladeSensor9Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 23 }
|
|
|
|
bladeSensor10Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 24 }
|
|
|
|
bladeSensor11Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 25 }
|
|
|
|
bladeSensor12Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 26 }
|
|
|
|
bladeSensor13Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 27 }
|
|
|
|
bladeSensor14Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 28 }
|
|
|
|
bladeSensor15Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 29 }
|
|
|
|
bladeSensor16Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 30 }
|
|
|
|
bladeSensor17Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 31 }
|
|
|
|
bladeSensor18Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 32 }
|
|
|
|
bladeSensor19Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 33 }
|
|
|
|
bladeSensor20Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 34 }
|
|
|
|
bladeSensor21Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 35 }
|
|
|
|
bladeSensor22Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 36 }
|
|
|
|
bladeSensor23Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 37 }
|
|
|
|
bladeSensor24Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 38 }
|
|
|
|
bladeSensor25Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 39 }
|
|
|
|
|
|
bladeSensor26Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 40 }
|
|
|
|
bladeSensor27Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 41 }
|
|
|
|
|
|
bladeSensor28Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 42 }
|
|
|
|
bladeSensor29Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 43 }
|
|
|
|
bladeSensor30Volt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage reading for an IPMI blade expressed in Volts(V).
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltagesEntry 44 }
|
|
|
|
|
|
bladeVoltageThresholdsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeVoltageThresholdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade VoltageThresholds information."
|
|
::= { bladeMonitors 6 }
|
|
|
|
|
|
bladeVoltageThresholdsEntry OBJECT-TYPE
|
|
SYNTAX BladeVoltageThresholdsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade voltage thresholds table entry"
|
|
INDEX { voltageThresholdIndex }
|
|
::= { bladeVoltageThresholdsTable 1 }
|
|
|
|
|
|
BladeVoltageThresholdsEntry ::= SEQUENCE {
|
|
voltageThresholdIndex INTEGER,
|
|
voltageThresholdBladeId INTEGER,
|
|
voltageThresholdBladeExists INTEGER,
|
|
voltageThresholdBladePowerState INTEGER,
|
|
voltageThresholdBladeName OCTET STRING,
|
|
bladePlus5VoltHighWarning OCTET STRING,
|
|
bladePlus5VoltLowWarning OCTET STRING,
|
|
bladePlus3pt3VoltHighWarning OCTET STRING,
|
|
bladePlus3pt3VoltLowWarning OCTET STRING,
|
|
bladePlus12VoltHighWarning OCTET STRING,
|
|
bladePlus12VoltLowWarning OCTET STRING,
|
|
bladePlus2pt5VoltHighWarning OCTET STRING,
|
|
bladePlus2pt5VoltLowWarning OCTET STRING,
|
|
bladePlus1pt5VoltHighWarning OCTET STRING,
|
|
bladePlus1pt5VoltLowWarning OCTET STRING,
|
|
bladePlus1pt25VoltHighWarning OCTET STRING,
|
|
bladePlus1pt25VoltLowWarning OCTET STRING,
|
|
bladeVoltThresholdSensorCapability INTEGER,
|
|
bladeSensor1VoltHighWarning OCTET STRING,
|
|
bladeSensor1VoltLowWarning OCTET STRING,
|
|
bladeSensor2VoltHighWarning OCTET STRING,
|
|
bladeSensor2VoltLowWarning OCTET STRING,
|
|
bladeSensor3VoltHighWarning OCTET STRING,
|
|
bladeSensor3VoltLowWarning OCTET STRING,
|
|
bladeSensor4VoltHighWarning OCTET STRING,
|
|
bladeSensor4VoltLowWarning OCTET STRING,
|
|
bladeSensor5VoltHighWarning OCTET STRING,
|
|
bladeSensor5VoltLowWarning OCTET STRING,
|
|
bladeSensor6VoltHighWarning OCTET STRING,
|
|
bladeSensor6VoltLowWarning OCTET STRING,
|
|
bladeSensor7VoltHighWarning OCTET STRING,
|
|
bladeSensor7VoltLowWarning OCTET STRING,
|
|
bladeSensor8VoltHighWarning OCTET STRING,
|
|
bladeSensor8VoltLowWarning OCTET STRING,
|
|
bladeSensor9VoltHighWarning OCTET STRING,
|
|
bladeSensor9VoltLowWarning OCTET STRING,
|
|
bladeSensor10VoltHighWarning OCTET STRING,
|
|
bladeSensor10VoltLowWarning OCTET STRING,
|
|
bladeSensor11VoltHighWarning OCTET STRING,
|
|
bladeSensor11VoltLowWarning OCTET STRING,
|
|
bladeSensor12VoltHighWarning OCTET STRING,
|
|
bladeSensor12VoltLowWarning OCTET STRING,
|
|
bladeSensor13VoltHighWarning OCTET STRING,
|
|
bladeSensor13VoltLowWarning OCTET STRING,
|
|
bladeSensor14VoltHighWarning OCTET STRING,
|
|
bladeSensor14VoltLowWarning OCTET STRING,
|
|
bladeSensor15VoltHighWarning OCTET STRING,
|
|
bladeSensor15VoltLowWarning OCTET STRING,
|
|
bladeSensor16VoltHighWarning OCTET STRING,
|
|
bladeSensor16VoltLowWarning OCTET STRING,
|
|
bladeSensor17VoltHighWarning OCTET STRING,
|
|
bladeSensor17VoltLowWarning OCTET STRING,
|
|
bladeSensor18VoltHighWarning OCTET STRING,
|
|
bladeSensor18VoltLowWarning OCTET STRING,
|
|
bladeSensor19VoltHighWarning OCTET STRING,
|
|
bladeSensor19VoltLowWarning OCTET STRING,
|
|
bladeSensor20VoltHighWarning OCTET STRING,
|
|
bladeSensor20VoltLowWarning OCTET STRING,
|
|
bladeSensor21VoltHighWarning OCTET STRING,
|
|
bladeSensor21VoltLowWarning OCTET STRING,
|
|
bladeSensor22VoltHighWarning OCTET STRING,
|
|
bladeSensor22VoltLowWarning OCTET STRING,
|
|
bladeSensor23VoltHighWarning OCTET STRING,
|
|
bladeSensor23VoltLowWarning OCTET STRING,
|
|
bladeSensor24VoltHighWarning OCTET STRING,
|
|
bladeSensor24VoltLowWarning OCTET STRING,
|
|
bladeSensor25VoltHighWarning OCTET STRING,
|
|
bladeSensor25VoltLowWarning OCTET STRING,
|
|
bladeSensor26VoltHighWarning OCTET STRING,
|
|
bladeSensor26VoltLowWarning OCTET STRING,
|
|
bladeSensor27VoltHighWarning OCTET STRING,
|
|
bladeSensor27VoltLowWarning OCTET STRING,
|
|
bladeSensor28VoltHighWarning OCTET STRING,
|
|
bladeSensor28VoltLowWarning OCTET STRING,
|
|
bladeSensor29VoltHighWarning OCTET STRING,
|
|
bladeSensor29VoltLowWarning OCTET STRING,
|
|
bladeSensor30VoltHighWarning OCTET STRING,
|
|
bladeSensor30VoltLowWarning OCTET STRING
|
|
}
|
|
|
|
voltageThresholdIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade voltage thresholds table index."
|
|
::= { bladeVoltageThresholdsEntry 1 }
|
|
|
|
|
|
voltageThresholdBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeVoltageThresholdsEntry 2 }
|
|
|
|
voltageThresholdBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeVoltageThresholdsEntry 3 }
|
|
|
|
voltageThresholdBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
standby(3),
|
|
hibernate(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the power state of the blade specified."
|
|
::= { bladeVoltageThresholdsEntry 4 }
|
|
|
|
voltageThresholdBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeVoltageThresholdsEntry 5 }
|
|
|
|
bladePlus5VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 6 }
|
|
|
|
bladePlus5VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 7 }
|
|
|
|
bladePlus3pt3VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 8 }
|
|
|
|
bladePlus3pt3VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 9 }
|
|
|
|
bladePlus12VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 10 }
|
|
|
|
bladePlus12VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 11 }
|
|
|
|
bladePlus2pt5VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 14 }
|
|
|
|
bladePlus2pt5VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 15 }
|
|
|
|
bladePlus1pt5VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 16 }
|
|
|
|
bladePlus1pt5VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 17 }
|
|
|
|
bladePlus1pt25VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage rises above this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 18 }
|
|
|
|
bladePlus1pt25VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading expressed in Volts(V).
|
|
If the voltage drops below this value a warning alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 19 }
|
|
|
|
bladeVoltThresholdSensorCapability OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade is IPMI capable or not."
|
|
::= { bladeVoltageThresholdsEntry 22 }
|
|
|
|
bladeSensor1VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 23 }
|
|
|
|
bladeSensor1VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 24 }
|
|
|
|
bladeSensor2VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 25 }
|
|
|
|
bladeSensor2VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 26 }
|
|
|
|
bladeSensor3VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 27 }
|
|
|
|
bladeSensor3VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 28 }
|
|
|
|
bladeSensor4VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 29 }
|
|
|
|
bladeSensor4VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 30 }
|
|
|
|
bladeSensor5VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 31 }
|
|
|
|
bladeSensor5VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 32 }
|
|
|
|
bladeSensor6VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 33 }
|
|
|
|
bladeSensor6VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 34 }
|
|
|
|
bladeSensor7VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 35 }
|
|
|
|
bladeSensor7VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 36 }
|
|
|
|
bladeSensor8VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 37 }
|
|
|
|
bladeSensor8VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 38 }
|
|
|
|
bladeSensor9VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 39 }
|
|
|
|
bladeSensor9VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 40 }
|
|
|
|
bladeSensor10VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 41 }
|
|
|
|
bladeSensor10VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 42 }
|
|
|
|
bladeSensor11VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 43 }
|
|
|
|
bladeSensor11VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 44 }
|
|
|
|
bladeSensor12VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 45 }
|
|
|
|
bladeSensor12VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 46 }
|
|
|
|
bladeSensor13VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 47 }
|
|
|
|
bladeSensor13VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 48 }
|
|
|
|
bladeSensor14VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 49 }
|
|
|
|
bladeSensor14VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 50 }
|
|
|
|
bladeSensor15VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 51 }
|
|
|
|
bladeSensor15VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 52 }
|
|
|
|
bladeSensor16VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 53 }
|
|
|
|
bladeSensor16VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 54 }
|
|
|
|
bladeSensor17VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 55 }
|
|
|
|
bladeSensor17VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 56 }
|
|
|
|
bladeSensor18VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 57 }
|
|
|
|
bladeSensor18VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 58 }
|
|
|
|
bladeSensor19VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 59 }
|
|
|
|
bladeSensor19VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 60 }
|
|
|
|
bladeSensor20VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 61 }
|
|
|
|
bladeSensor20VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 62 }
|
|
|
|
bladeSensor21VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 63 }
|
|
|
|
bladeSensor21VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 64 }
|
|
|
|
bladeSensor22VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 65 }
|
|
|
|
bladeSensor22VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 66 }
|
|
|
|
bladeSensor23VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 67 }
|
|
|
|
bladeSensor23VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 68 }
|
|
|
|
bladeSensor24VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 69 }
|
|
|
|
bladeSensor24VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 70 }
|
|
|
|
bladeSensor25VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 71 }
|
|
|
|
bladeSensor25VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 72 }
|
|
|
|
|
|
bladeSensor26VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 73 }
|
|
|
|
bladeSensor26VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 74 }
|
|
|
|
bladeSensor27VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 75 }
|
|
|
|
bladeSensor27VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 76 }
|
|
|
|
bladeSensor28VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 77 }
|
|
|
|
bladeSensor28VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 78 }
|
|
|
|
bladeSensor29VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 79 }
|
|
|
|
bladeSensor29VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 80 }
|
|
|
|
bladeSensor30VoltHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage rises above this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 81 }
|
|
|
|
bladeSensor30VoltLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Voltage warning threshold reading for IPMI blades expressed in Volts(V).
|
|
If the voltage drops below this value, a critical alert/event
|
|
if enabled will be generated.
|
|
An octet string expressed as 'sdd.dd Volts' where:
|
|
s is the sign ('-' for negative or '+' for positive)
|
|
d is a decimal digit or blank space for a leading zero.
|
|
The string 'Not Readable!' indicates that the given monitor
|
|
is not supported on this system.
|
|
The string 'No Voltage' indicates that the given monitor
|
|
does not exist on this system or is powered off."
|
|
::= { bladeVoltageThresholdsEntry 82 }
|
|
|
|
bladeIOCompatibilityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeIOCompatibilityEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of IO Compatibility status for the blade."
|
|
::= { bladeMonitors 7 }
|
|
|
|
bladeIOCompatibilityEntry OBJECT-TYPE
|
|
SYNTAX BladeIOCompatibilityEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade IO Compatibility Status entry"
|
|
INDEX { bladeIOCompatibilityIndex }
|
|
::= { bladeIOCompatibilityTable 1 }
|
|
|
|
BladeIOCompatibilityEntry ::= SEQUENCE {
|
|
bladeIOCompatibilityIndex INTEGER,
|
|
bladeIOCompatibilityBladeId INTEGER,
|
|
bladeIOCompatibilityBayNumber INTEGER,
|
|
bladeIOCompatibilityModuleBay OCTET STRING,
|
|
bladeIOCompatibilityModulePower OCTET STRING,
|
|
bladeIOCompatibilityModuleFabricType OCTET STRING,
|
|
bladeIOCompatibilityFabricOnBlade OCTET STRING,
|
|
bladeIOCompatibilityStatus OCTET STRING
|
|
}
|
|
|
|
bladeIOCompatibilityIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade I/O compatibility table index."
|
|
::= { bladeIOCompatibilityEntry 1 }
|
|
|
|
|
|
bladeIOCompatibilityBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade numeric identifier."
|
|
::= { bladeIOCompatibilityEntry 2 }
|
|
|
|
bladeIOCompatibilityBayNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Bay number of the blade or expension card."
|
|
::= { bladeIOCompatibilityEntry 3 }
|
|
|
|
bladeIOCompatibilityModuleBay OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The modules (each one specified by module type and bay number)
|
|
that the blade can communicate with over the midplane networking fabric
|
|
(i.e. a physical path exists between the blade and this module, and
|
|
hardware exists on the blade to communicate with this module). "
|
|
::= { bladeIOCompatibilityEntry 4 }
|
|
|
|
bladeIOCompatibilityModulePower OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power state of the module specified in bladeIOCompatibilityModuleBay.
|
|
n/a if module not installed."
|
|
::= { bladeIOCompatibilityEntry 5 }
|
|
|
|
bladeIOCompatibilityModuleFabricType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fabric type of the module specified in bladeIOCompatibilityModuleBay."
|
|
::= { bladeIOCompatibilityEntry 6 }
|
|
|
|
bladeIOCompatibilityFabricOnBlade OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fabric type for this channel on the blade (may be onboard fabric or
|
|
an expansion card)."
|
|
::= { bladeIOCompatibilityEntry 7 }
|
|
|
|
bladeIOCompatibilityStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The compatibility status between the blade and the module specified
|
|
in bladeIOCompatibilityModuleBay.
|
|
|
|
The possible values are:
|
|
OK: No compatibility issues
|
|
No IOM: There is no module on the other side of the wire for this channel on the blade.
|
|
n/a: (Not applicable) The module specified in bladeIOCompatibilityModuleBay is a bridge,
|
|
so the blade port cannot connect to it.
|
|
Attention: The module specified in bladeIOCompatibilityModuleBay has a communication error.
|
|
Mismatch: Indicates one of the following cases:
|
|
Fabric types are incompatible
|
|
Module specified in bladeIOCompatibilityModuleBay is of unknown type
|
|
Unknown fabric type on the blade"
|
|
::= { bladeIOCompatibilityEntry 8 }
|
|
|
|
bladePowerRestart OBJECT IDENTIFIER ::= { processorBlade 6 }
|
|
-- blade power/restart control
|
|
|
|
bladePowerRestartTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladePowerRestartEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade remote power control information.
|
|
Contains power on/off enablement status for each blade."
|
|
::= { bladePowerRestart 1 }
|
|
|
|
bladePowerRestartEntry OBJECT-TYPE
|
|
SYNTAX BladePowerRestartEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade power restart table entry"
|
|
INDEX { powerRestartIndex }
|
|
::= { bladePowerRestartTable 1 }
|
|
|
|
|
|
BladePowerRestartEntry ::= SEQUENCE {
|
|
powerRestartIndex INTEGER,
|
|
powerRestartBladeId INTEGER,
|
|
powerRestartBladeExists INTEGER,
|
|
powerRestartBladePowerState INTEGER,
|
|
powerRestartBladeHealthState INTEGER,
|
|
powerRestartBladeName OCTET STRING,
|
|
powerOnOffBlade INTEGER,
|
|
restartBlade INTEGER,
|
|
restartBladeSMP INTEGER,
|
|
restartBladeNMI INTEGER,
|
|
restartBladeClearNVRAM INTEGER,
|
|
restartBladeInvokeDiags INTEGER,
|
|
restartBladeInvokeDiagsFromDefaultBootList INTEGER,
|
|
restartBladeToSMSBootMenu INTEGER,
|
|
restartBladeToUEFIMenu INTEGER
|
|
}
|
|
|
|
powerRestartIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade power restart table index."
|
|
::= { bladePowerRestartEntry 1 }
|
|
|
|
|
|
powerRestartBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladePowerRestartEntry 2 }
|
|
|
|
powerRestartBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladePowerRestartEntry 3 }
|
|
|
|
powerRestartBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
standby(3),
|
|
hibernate(4),
|
|
unknown(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the power state of the blade specified.
|
|
If the state cannot be determined, the unknown(255)
|
|
value is returned."
|
|
::= { bladePowerRestartEntry 4 }
|
|
|
|
powerRestartBladeHealthState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
critical(3),
|
|
kernelMode(4),
|
|
discovering(5),
|
|
commError(6),
|
|
noPower(7),
|
|
flashing(8),
|
|
initFailure(9),
|
|
insufficientPower(10),
|
|
powerDenied(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The system health state for the blade.
|
|
|
|
Unknown: Blade is in an undefined state.
|
|
Good: Blade is operating normally.
|
|
Warning: One or more outstanding warnings exist for this blade.
|
|
Critical: One or more outstanding critical events for this blade.
|
|
Kernel Mode: Blade is in kernel mode.
|
|
Discovering: The AMM is currently in the process of discovering this blade.
|
|
Communications Error: The AMM failed to communicate with this blade.
|
|
No Power: No power to the blade's domain.
|
|
Flashing: Flashing in progress.
|
|
Initialization Failure: Blade failed to initialized.
|
|
Insufficient Power: Not enough power is left in the blade's domain to power the blade.
|
|
Power Denied: Power was denied to the blade."
|
|
::= { bladePowerRestartEntry 5 }
|
|
|
|
powerRestartBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladePowerRestartEntry 6 }
|
|
|
|
powerOnOffBlade OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
softoff(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the power state of a specific blade.
|
|
|
|
Off: Power Off Blade.
|
|
On: Power On Blade.
|
|
Softoff: Shut Down OS and Power Off Blade. This operation is not
|
|
supported on all blades.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object. The powerRestartBladePowerState MIB object should be
|
|
used to check the power state of the blade(s)"
|
|
::= { bladePowerRestartEntry 7 }
|
|
|
|
restartBlade OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Restart a blade.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object."
|
|
::= { bladePowerRestartEntry 8 }
|
|
|
|
restartBladeSMP OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Restart a blade's system management processor.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object."
|
|
::= { bladePowerRestartEntry 9 }
|
|
|
|
restartBladeNMI OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Issue an NMI to the blade. This option is not supported
|
|
on all blades.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object."
|
|
::= { bladePowerRestartEntry 10 }
|
|
|
|
restartBladeClearNVRAM OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Restart a blade and set NVRAM to default values. This option is not
|
|
supported on all blades.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object."
|
|
::= { bladePowerRestartEntry 11 }
|
|
|
|
restartBladeInvokeDiags OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Restart a blade and boot into diagnostic mode. This option is not
|
|
supported on all blades.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object."
|
|
::= { bladePowerRestartEntry 12 }
|
|
|
|
restartBladeInvokeDiagsFromDefaultBootList OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Restart a blade and boot into diagnostic mode from Default Boot List
|
|
as defined on the blade. This option is not supported on all blades.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object."
|
|
::= { bladePowerRestartEntry 13 }
|
|
|
|
restartBladeToSMSBootMenu OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Restart a blade to SMS boot menu. This option is not supported on
|
|
all blades.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object."
|
|
::= { bladePowerRestartEntry 14 }
|
|
|
|
restartBladeToUEFIMenu OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Restart a blade to UEFI setup menu. This option is not supported on
|
|
all blades.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object."
|
|
::= { bladePowerRestartEntry 15 }
|
|
|
|
|
|
bladeConfiguration OBJECT IDENTIFIER ::= { processorBlade 7 }
|
|
-- blade power/restart control
|
|
|
|
bladeConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeConfigurationEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade remote power control information.
|
|
Contains power on/off enablement status for each blade."
|
|
::= { bladeConfiguration 1 }
|
|
|
|
bladeConfigurationEntry OBJECT-TYPE
|
|
SYNTAX BladeConfigurationEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade configuration table entry"
|
|
INDEX { configurationIndex }
|
|
::= { bladeConfigurationTable 1 }
|
|
|
|
|
|
BladeConfigurationEntry ::= SEQUENCE {
|
|
configurationIndex INTEGER,
|
|
configurationBladeId INTEGER,
|
|
configurationBladeExists INTEGER,
|
|
configurationBladePowerState INTEGER,
|
|
configurationBladeName OCTET STRING,
|
|
configurationBladecKVM INTEGER,
|
|
configurationBladeActiveBootMode INTEGER,
|
|
configurationBladePendingBootMode INTEGER
|
|
}
|
|
|
|
configurationIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade configuration table index."
|
|
::= { bladeConfigurationEntry 1 }
|
|
|
|
|
|
configurationBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeConfigurationEntry 2 }
|
|
|
|
configurationBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeConfigurationEntry 3 }
|
|
|
|
configurationBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
standby(3),
|
|
hibernate(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the power state of the blade specified."
|
|
::= { bladeConfigurationEntry 4 }
|
|
|
|
configurationBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeConfigurationEntry 5 }
|
|
|
|
configurationBladecKVM OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1),
|
|
notPresent(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the concurrent KVM function on specified blade.
|
|
If concurrent KVM is not supported by the blade, it displays 'notPresent'
|
|
and the concurrent KVM functionality can not be enabled or disabled."
|
|
::= { bladeConfigurationEntry 6 }
|
|
|
|
configurationBladeActiveBootMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
temporary(1),
|
|
permanent(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the active copy of the firmware from which the blade is booting.
|
|
NOTE: Some blades do not support the automatic boot recovery. It displays
|
|
'notApplicable' for such blades.
|
|
Booting from the temporary copy is recommended since it typically contains the
|
|
latest enhancements and fixes. Switching to the permanent copy should be reserved
|
|
for when booting from the temporary copy is no longer possible."
|
|
::= { bladeConfigurationEntry 7 }
|
|
|
|
configurationBladePendingBootMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
temporary(1),
|
|
permanent(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the copy of the firmware from which the blade will boot
|
|
after the next reboot.
|
|
NOTE: Some blades do not support the automatic boot recovery. It displays
|
|
'notApplicable' for such blades and the value can not be set.
|
|
Booting from the temporary copy is recommended since it typically contains the
|
|
latest enhancements and fixes. Switching to the permanent copy should be reserved
|
|
for when booting from the temporary copy is no longer possible."
|
|
::= { bladeConfigurationEntry 8 }
|
|
|
|
-- Power Management Policy Settings
|
|
bladePowerManagementPolicy OBJECT IDENTIFIER ::= { bladeConfiguration 2 }
|
|
|
|
powerdomain1Oversubscription OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
not-allowed(0),
|
|
recoverable(1),
|
|
non-recoverable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Management Policy settings for power domain 1."
|
|
::= { bladePowerManagementPolicy 1 }
|
|
|
|
powerdomain2Oversubscription OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
not-allowed(0),
|
|
recoverable(1),
|
|
non-recoverable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power Management Policy settings for power domain 2."
|
|
::= { bladePowerManagementPolicy 2 }
|
|
|
|
acousticMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Acoustic mode setting for thermal conditions"
|
|
::= { bladePowerManagementPolicy 3 }
|
|
|
|
nebsMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"NEBS (Network Equipment-Building System) mode setting for thermal conditions.
|
|
NOTE: This MIB object is for BladeCenter T, HT and TR only."
|
|
::= { bladePowerManagementPolicy 4 }
|
|
|
|
bladecKVMEnableDisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable cKVM function on all server blades."
|
|
::= { bladeConfiguration 3 }
|
|
|
|
bladeIPAddrRangeStart OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This field is used to configure the start of the IP address range for the blade
|
|
system management processors on the blades. These addresses are used on the
|
|
internal management network between the MM and the blade BSMPs. For example the
|
|
value of 10.10.10.1 means the BSMP on the blade in bay 1 will have IP address
|
|
10.10.10.1, the BSMP on the blade in bay 2 will have IP address 10.10.10.2 and so on.
|
|
|
|
This field is deprecated and no longer supported. An attempt to SET this
|
|
object will be rejected, and any query will always return 0.0.0.0.
|
|
Refer to the bladeManagementNetworkInfoTable for the new objects providing
|
|
this information."
|
|
::= { processorBlade 8 }
|
|
|
|
bladeCapacityOnDemand OBJECT IDENTIFIER ::= { processorBlade 9 }
|
|
|
|
bladeCapacityOnDemandTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeCapacityOnDemandEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Table of COD blade.
|
|
|
|
NOTE: This table is deprecated and no longer supported."
|
|
::= { bladeCapacityOnDemand 1 }
|
|
|
|
bladeCapacityOnDemandEntry OBJECT-TYPE
|
|
SYNTAX BladeCapacityOnDemandEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Blade COD table entry
|
|
NOTE: This table is deprecated and no longer supported."
|
|
INDEX { bladeCapacityOnDemandIndex }
|
|
::= { bladeCapacityOnDemandTable 1 }
|
|
|
|
BladeCapacityOnDemandEntry ::= SEQUENCE {
|
|
bladeCapacityOnDemandIndex INTEGER, -- deprecated
|
|
bladeCapacityOnDemandBladeName OCTET STRING, -- deprecated
|
|
bladeCapacityOnDemandState INTEGER -- deprecated
|
|
}
|
|
|
|
bladeCapacityOnDemandIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Blade configuration table index.
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { bladeCapacityOnDemandEntry 1 }
|
|
|
|
bladeCapacityOnDemandBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string.
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { bladeCapacityOnDemandEntry 2 }
|
|
|
|
bladeCapacityOnDemandState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
standby(1),
|
|
active(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The state of Capacity On Demand.
|
|
NOTE: This Mib object is deprecated and no longer supported."
|
|
::= { bladeCapacityOnDemandEntry 3 }
|
|
|
|
|
|
bladeBootCountPowerOnTime OBJECT IDENTIFIER ::= { processorBlade 10 }
|
|
-- blade Count of number of boots for a blade and its Power On Time
|
|
|
|
bladeBootCountPowerOnTimeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeBootCountPowerOnTimeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table per blade of the number of boots for the blade and
|
|
the number of seconds the blade has been powered on."
|
|
::= { bladeBootCountPowerOnTime 1 }
|
|
|
|
bladeBootCountPowerOnTimeEntry OBJECT-TYPE
|
|
SYNTAX BladeBootCountPowerOnTimeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of boots for the blade and
|
|
the number of seconds the blade has been powered on."
|
|
INDEX { bootCountPowerOnTimeBladeIndex }
|
|
::= { bladeBootCountPowerOnTimeTable 1 }
|
|
|
|
|
|
BladeBootCountPowerOnTimeEntry ::= SEQUENCE {
|
|
bootCountPowerOnTimeBladeIndex INTEGER,
|
|
bootCountPowerOnTimeBladeId INTEGER,
|
|
bootCountPowerOnTimeBoots INTEGER,
|
|
bootCountPowerOnTimeSecs INTEGER
|
|
}
|
|
|
|
bootCountPowerOnTimeBladeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade boot count/Power On Time table index."
|
|
::= { bladeBootCountPowerOnTimeEntry 1 }
|
|
|
|
bootCountPowerOnTimeBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeBootCountPowerOnTimeEntry 2 }
|
|
|
|
bootCountPowerOnTimeBoots OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Boot Count. If there is no blade in the
|
|
given slot then this value is undefined. Writing this
|
|
value resets the Boot Count to zero."
|
|
::= { bladeBootCountPowerOnTimeEntry 3 }
|
|
|
|
bootCountPowerOnTimeSecs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Power On Time in seconds. If there is no blade in
|
|
the given slot then this value is undefined. Writing this
|
|
value resets the Power On Time to zero."
|
|
::= { bladeBootCountPowerOnTimeEntry 4 }
|
|
|
|
bladeVlanId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the virtual LAN ID for the internal management network between the MM and
|
|
the blade system management processors (BSMPs). The range of valid VLAN ID's
|
|
is 3 to 4095."
|
|
::= { processorBlade 11 }
|
|
|
|
|
|
---
|
|
--- Blade Bay Data Table MIB objects
|
|
---
|
|
bladeBayDataTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeBayDataEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade bay data (BBD) information."
|
|
::= { processorBlade 13 }
|
|
|
|
bladeBayDataEntry OBJECT-TYPE
|
|
SYNTAX BladeBayDataEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade bay data (BBD) table entry."
|
|
INDEX { bayDataIndex }
|
|
::= { bladeBayDataTable 1 }
|
|
|
|
BladeBayDataEntry ::= SEQUENCE {
|
|
bayDataIndex INTEGER,
|
|
bayDataBladeId INTEGER,
|
|
bayDataBladeExists INTEGER,
|
|
bayDataBladePowerState INTEGER,
|
|
bayDataBladeName OCTET STRING,
|
|
bayData OCTET STRING,
|
|
bayDataBladeStatus INTEGER
|
|
}
|
|
|
|
bayDataIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade bay data (BBD) table index."
|
|
::= { bladeBayDataEntry 1 }
|
|
|
|
bayDataBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeBayDataEntry 2 }
|
|
|
|
bayDataBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the server blade specified exists or not."
|
|
::= { bladeBayDataEntry 3 }
|
|
|
|
bayDataBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
standby(3),
|
|
hibernate(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the power state of the blade specified."
|
|
::= { bladeBayDataEntry 4 }
|
|
|
|
bayDataBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { bladeBayDataEntry 5 }
|
|
|
|
|
|
bayData OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A null terminated string that defines the Blade Bay Data (BBD). This data
|
|
is pushed to the blade's BSMP and SMBIOS structures, where it can used
|
|
by the blade's OS. Up to 60 characters can be defined plus a Null
|
|
terminator."
|
|
::= { bladeBayDataEntry 6 }
|
|
|
|
bayDataBladeStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
supported(0),
|
|
bsmp(1),
|
|
notPresent(2),
|
|
discovering(3),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This shows Blade Bay Data (BBD) status. 0 means the blade fully
|
|
supports BBD; 1 means that the blade's BIOS does not support BBD;
|
|
2 means that there is no blade in the bay; 3 means that the blade is
|
|
being discovered. 255 means that the blade does not support BBD."
|
|
::= { bladeBayDataEntry 7 }
|
|
|
|
|
|
bladeNetworkConfiguration OBJECT IDENTIFIER ::= { processorBlade 12 }
|
|
-- blade network configuration for all blades
|
|
|
|
bladeNetworkInterfaceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeNetworkInterfaceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of all blades' network interfaces."
|
|
::= { bladeNetworkConfiguration 2 }
|
|
|
|
bladeNetworkInterfaceEntry OBJECT-TYPE
|
|
SYNTAX BladeNetworkInterfaceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade configuration table entry"
|
|
INDEX { bladeNetworkInterfaceIndex }
|
|
::= { bladeNetworkInterfaceTable 1 }
|
|
|
|
BladeNetworkInterfaceEntry ::= SEQUENCE {
|
|
bladeNetworkInterfaceIndex INTEGER,
|
|
bladeNetworkInterfaceBayNumber OCTET STRING,
|
|
bladeNetworkInterfaceNumber INTEGER,
|
|
bladeNetworkInterfaceType INTEGER,
|
|
bladeNetworkInterfaceLabel OCTET STRING,
|
|
bladeNetworkInterfaceIPAddr IpAddress,
|
|
bladeNetworkInterfaceSubnetMask IpAddress,
|
|
bladeNetworkInterfaceGatewayAddr IpAddress,
|
|
bladeNetworkInterfaceVlanId INTEGER,
|
|
bladeNetworkInterfaceVlanEnable INTEGER,
|
|
bladeNetworkInterfaceEnable INTEGER,
|
|
bladeNetworkInterfaceDHCPEnable INTEGER,
|
|
bladeNetworkInterfaceMACAddr OCTET STRING,
|
|
bladeNetworkInterfaceAssignedSwitch INTEGER
|
|
}
|
|
|
|
bladeNetworkInterfaceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Network Interface Table index."
|
|
::= { bladeNetworkInterfaceEntry 1 }
|
|
|
|
bladeNetworkInterfaceBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bay number of the main server blade that supports network interface management"
|
|
::= { bladeNetworkInterfaceEntry 2 }
|
|
|
|
bladeNetworkInterfaceNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates which network interface on the blade System Management Processor is be read or writen"
|
|
::= { bladeNetworkInterfaceEntry 3 }
|
|
|
|
bladeNetworkInterfaceType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
private(1),
|
|
public(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates blade network interface type."
|
|
::= { bladeNetworkInterfaceEntry 4 }
|
|
|
|
bladeNetworkInterfaceLabel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Show string label that identifies the interface."
|
|
::= { bladeNetworkInterfaceEntry 5 }
|
|
|
|
bladeNetworkInterfaceIPAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Show/modify current IP address of the blade network interface.
|
|
Note that only if the bladeNetworkInterfaceEnable is 'enabled(1)' and the bladeNetworkInterfaceDHCPEnable is not 'dhcpEnabled(1)', should the IP address be
|
|
pushed down to blade System Management Processor"
|
|
::= { bladeNetworkInterfaceEntry 6 }
|
|
|
|
bladeNetworkInterfaceSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Show or modifie current subnet mask of the blade network interface.
|
|
Note that only if the bladeNetworkInterfaceEnable is 'enabled(1)' and the bladeNetworkInterfaceDHCPEnable is not 'dhcpEnabled(1)', should the SunnetMask be
|
|
pushed down to blade System Management Processor"
|
|
::= { bladeNetworkInterfaceEntry 7 }
|
|
|
|
bladeNetworkInterfaceGatewayAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Show or modify current IP gateway of the blade network interface.
|
|
Note that only if the bladeNetworkInterfaceEnable is 'enabled(1)' and the bladeNetworkInterfaceDHCPEnable is not 'dhcpEnabled(1)', should the Gateway address be
|
|
pushed down to blade System Management Processor"
|
|
::= { bladeNetworkInterfaceEntry 8 }
|
|
|
|
bladeNetworkInterfaceVlanId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the Virtual LAN ID for supported network interface cards (NICs).
|
|
The range of valid VLAN ID's is 0 to 4095."
|
|
::= { bladeNetworkInterfaceEntry 9 }
|
|
|
|
bladeNetworkInterfaceVlanEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object is no longer supported and will always be 0"
|
|
::= { bladeNetworkInterfaceEntry 10 }
|
|
|
|
bladeNetworkInterfaceEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disabled or enabled the blade network interface. If the network interface is disabled, then ignore other configurations.
|
|
If this network interface doesn't support enabled/disabled, show 'notApplicable(255)'"
|
|
::= { bladeNetworkInterfaceEntry 11 }
|
|
|
|
bladeNetworkInterfaceDHCPEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dhcpDisabled(0),
|
|
dhcpEnabled(1),
|
|
tryDhcpThenTryStatic(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP config method on the blade network interface to modify mode to static IP, dhcp and dhcpthenstatic.
|
|
If this network interface doesn't support DHCP, show 'notApplicable(255)'"
|
|
::= { bladeNetworkInterfaceEntry 12 }
|
|
|
|
bladeNetworkInterfaceMACAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Show the blade network interface MAC address. If this network interface doesn't support MAC, show 'notApplicable'"
|
|
::= { bladeNetworkInterfaceEntry 13 }
|
|
|
|
bladeNetworkInterfaceAssignedSwitch OBJECT-TYPE
|
|
SYNTAX INTEGER { notAssigned(0), module1(1), module2(2), module3(3), module4(4),
|
|
module5(5), module6(6), module7(7), module8(8), module9(9), module10(10),
|
|
notApplicable(255)}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This field allows you to select an I/O Module to use for
|
|
management traffic to the blade.
|
|
|
|
NOTE: This field is only supported for eth1 of blade.
|
|
NOTE: You may only specify ethernet switches to this field."
|
|
::= { bladeNetworkInterfaceEntry 14 }
|
|
|
|
|
|
bladeIPv6Config OBJECT IDENTIFIER ::= { bladeNetworkConfiguration 10 }
|
|
bladeIPv6ConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeIPv6ConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of IPv6 configuration options for blades.
|
|
|
|
NOTE: This MIB object is not applicable to blades that
|
|
do not support IPv6."
|
|
::= { bladeIPv6Config 1 }
|
|
|
|
bladeIPv6ConfigEntry OBJECT-TYPE
|
|
SYNTAX BladeIPv6ConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IPv6 configuration options for a blade.
|
|
|
|
NOTE: This MIB object is not applicable to blades that
|
|
do not support IPv6."
|
|
INDEX { bladeIPv6ConfigIndex, bladeIPv6ConfigPortIndex }
|
|
::= { bladeIPv6ConfigTable 1 }
|
|
|
|
BladeIPv6ConfigEntry ::= SEQUENCE {
|
|
bladeIPv6ConfigIndex INTEGER,
|
|
bladeIPv6ConfigPortIndex INTEGER,
|
|
bladeIPv6ConfigEnabled INTEGER,
|
|
bladeIPv6ConfigStatic INTEGER,
|
|
bladeDHCPv6ConfigEnabled INTEGER,
|
|
bladeIPv6ConfigStatelessEnabled INTEGER
|
|
}
|
|
|
|
bladeIPv6ConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade's slot number"
|
|
::= { bladeIPv6ConfigEntry 1 }
|
|
bladeIPv6ConfigPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The physical port number of the given entry"
|
|
::= { bladeIPv6ConfigEntry 2 }
|
|
bladeIPv6ConfigEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(0),enable(1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enables/Disables IPv6 support on the blade."
|
|
::= { bladeIPv6ConfigEntry 3 }
|
|
bladeIPv6ConfigStatic OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(0),enable(1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enables/Disables IPv6 static configuration support on the blade."
|
|
::= { bladeIPv6ConfigEntry 4 }
|
|
bladeDHCPv6ConfigEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(0),enable(1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enables/Disables DHCPv6 address configuration support on the blade."
|
|
::= { bladeIPv6ConfigEntry 5 }
|
|
bladeIPv6ConfigStatelessEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(0),enable(1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enables/Disables IPv6 stateless auto-configuration support on the blade."
|
|
::= { bladeIPv6ConfigEntry 6 }
|
|
|
|
bladeIPv6AddressTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeIPv6AddressEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of assigned IPv6 addresses for blades.
|
|
|
|
NOTE: This MIB object is not applicable to blades that
|
|
do not support IPv6."
|
|
::= { bladeIPv6Config 2 }
|
|
|
|
bladeIPv6AddressEntry OBJECT-TYPE
|
|
SYNTAX BladeIPv6AddressEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The assigned IPv6 address for a given blade.
|
|
|
|
NOTE: This MIB object is not applicable to blades that
|
|
do not support IPv6."
|
|
INDEX { bladeIPv6AddressIndex, bladeIPv6AddressPortIndex, bladeIPv6AddressEntryIndex}
|
|
::= { bladeIPv6AddressTable 1 }
|
|
|
|
BladeIPv6AddressEntry ::= SEQUENCE {
|
|
bladeIPv6AddressIndex INTEGER,
|
|
bladeIPv6AddressPortIndex INTEGER,
|
|
bladeIPv6AddressEntryIndex INTEGER,
|
|
bladeIPv6AddressType INTEGER,
|
|
bladeIPv6Address InetAddressIPv6,
|
|
bladeIPv6AddressPrefixLen INTEGER,
|
|
bladeIPv6AddressDefaultRoute InetAddressIPv6
|
|
}
|
|
|
|
bladeIPv6AddressIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade's slot number."
|
|
::= { bladeIPv6AddressEntry 1 }
|
|
bladeIPv6AddressPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade's physical port number for the given entry."
|
|
::= { bladeIPv6AddressEntry 2 }
|
|
bladeIPv6AddressEntryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade's address entry index."
|
|
::= { bladeIPv6AddressEntry 3 }
|
|
bladeIPv6AddressType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{ active-static(1),
|
|
dhcp6(2),
|
|
link-local(3),
|
|
autconfig(4),
|
|
current(5) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The address type."
|
|
::= { bladeIPv6AddressEntry 4 }
|
|
bladeIPv6Address OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The assigned IPv6 address.
|
|
Note: 'write' is for static ipv6 only."
|
|
::= { bladeIPv6AddressEntry 5 }
|
|
bladeIPv6AddressPrefixLen OBJECT-TYPE
|
|
SYNTAX INTEGER (1..128)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The prefix length for the given address.
|
|
Note: 'write' is for static ipv6 only."
|
|
::= { bladeIPv6AddressEntry 6 }
|
|
bladeIPv6AddressDefaultRoute OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The default route used for the given address.
|
|
Note: 'write' is for static ipv6 only."
|
|
::= { bladeIPv6AddressEntry 7 }
|
|
|
|
bladeSPEthOverUSBInterface OBJECT IDENTIFIER ::= { processorBlade 14 }
|
|
|
|
spEthOverUSBInterfaceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SPEthOverUSBInterfaceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade Service Processor's Ethernet over USB interface."
|
|
::= { bladeSPEthOverUSBInterface 1 }
|
|
|
|
spEthOverUSBInterfaceEntry OBJECT-TYPE
|
|
SYNTAX SPEthOverUSBInterfaceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade Service Processor's Ethernet over USB interface entry."
|
|
INDEX { spEthOverUSBInterfaceIndex }
|
|
::= { spEthOverUSBInterfaceTable 1 }
|
|
|
|
SPEthOverUSBInterfaceEntry ::= SEQUENCE {
|
|
spEthOverUSBInterfaceIndex INTEGER,
|
|
spEthOverUSBInterfaceBladeId OCTET STRING,
|
|
spEthOverUSBInterfaceBladeExists INTEGER,
|
|
spEthOverUSBInterfaceBladeName OCTET STRING,
|
|
spEthOverUSBInterfaceEnable INTEGER
|
|
}
|
|
|
|
spEthOverUSBInterfaceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Service Processor's Ethernet over USB interface table index."
|
|
::= { spEthOverUSBInterfaceEntry 1 }
|
|
|
|
spEthOverUSBInterfaceBladeId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { spEthOverUSBInterfaceEntry 2 }
|
|
|
|
spEthOverUSBInterfaceBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade specified exists or not."
|
|
::= { spEthOverUSBInterfaceEntry 3 }
|
|
|
|
spEthOverUSBInterfaceBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a null terminated string."
|
|
::= { spEthOverUSBInterfaceEntry 6 }
|
|
|
|
spEthOverUSBInterfaceEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object allows the user to view the status of, and enable
|
|
or disable, a blade Service Processor's command interface on
|
|
Ethernet-over-USB.
|
|
|
|
NOTE: If the blade either does not exist or does not support
|
|
Ethernet-over-USB command interface. It displays 'notApplicable'.
|
|
NOTE: It will take about 10 or more seconds for the disable/enable
|
|
setting to take effect."
|
|
::= { spEthOverUSBInterfaceEntry 9 }
|
|
|
|
-- Blade management network auto discovery
|
|
|
|
bladeManagementNetwork OBJECT IDENTIFIER ::= { processorBlade 15 }
|
|
|
|
bladeManagementNetworkControlEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Globally disable/enable blade management network auto discovery support."
|
|
::= { bladeManagementNetwork 1 }
|
|
|
|
--Blade Management Network Info Table
|
|
|
|
bladeManagementNetworkInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeManagementNetworkInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade management network information."
|
|
::= { bladeManagementNetwork 2 }
|
|
|
|
bladeManagementNetworkInfoEntry OBJECT-TYPE
|
|
SYNTAX BladeManagementNetworkInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management network information entry."
|
|
INDEX { bladeManagementNetworkInfoIndex }
|
|
::= { bladeManagementNetworkInfoTable 1 }
|
|
|
|
BladeManagementNetworkInfoEntry ::= SEQUENCE {
|
|
bladeManagementNetworkInfoIndex INTEGER,
|
|
bladeManagementNetworkInfoBladeId INTEGER,
|
|
bladeManagementNetworkInfoBladeExist INTEGER,
|
|
bladeManagementNetworkInfoBladeSupport INTEGER,
|
|
bladeManagementNetworkInfoPathStatus INTEGER,
|
|
bladeManagementNetworkInfoBladeIPAddr IpAddress,
|
|
bladeManagementNetworkInfoBladeMACAddr OCTET STRING,
|
|
bladeManagementNetworkInfoSwitchId INTEGER
|
|
}
|
|
|
|
bladeManagementNetworkInfoIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade management network information table index"
|
|
::= { bladeManagementNetworkInfoEntry 1 }
|
|
|
|
bladeManagementNetworkInfoBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Blade ID."
|
|
::= { bladeManagementNetworkInfoEntry 2 }
|
|
|
|
bladeManagementNetworkInfoBladeExist OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade specified exists or not in the chassis."
|
|
::= { bladeManagementNetworkInfoEntry 3 }
|
|
|
|
bladeManagementNetworkInfoBladeSupport OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade supports the management network auto discovery capability or not."
|
|
::= { bladeManagementNetworkInfoEntry 4 }
|
|
|
|
bladeManagementNetworkInfoPathStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the status of the management network for this blade."
|
|
::= { bladeManagementNetworkInfoEntry 5 }
|
|
|
|
bladeManagementNetworkInfoBladeIPAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the blade system management processor IPv4 address."
|
|
::= { bladeManagementNetworkInfoEntry 6 }
|
|
|
|
bladeManagementNetworkInfoBladeMACAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the blade system management processor MAC address."
|
|
::= { bladeManagementNetworkInfoEntry 7 }
|
|
|
|
bladeManagementNetworkInfoSwitchId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates which switch is selected for the blade management network."
|
|
::= { bladeManagementNetworkInfoEntry 8 }
|
|
|
|
-- ********************************************************************************
|
|
-- Switch module control and config
|
|
-- ********************************************************************************
|
|
switchModule OBJECT IDENTIFIER ::= { blades 3 }
|
|
-- Server blade switch module control and configuration
|
|
|
|
-- ********************************************************************************
|
|
-- Switch module control
|
|
-- ********************************************************************************
|
|
switchModuleControl OBJECT IDENTIFIER ::= { switchModule 1 }
|
|
-- Server blade switch module control
|
|
|
|
smControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module control table."
|
|
::= { switchModuleControl 1 }
|
|
|
|
smControlEntry OBJECT-TYPE
|
|
SYNTAX SmControlEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module control table entry"
|
|
INDEX { smControlIndex }
|
|
::= { smControlTable 1 }
|
|
|
|
SmControlEntry ::= SEQUENCE {
|
|
smControlIndex INTEGER,
|
|
switchModuleControlId INTEGER,
|
|
smPostResultsAvailable INTEGER,
|
|
smPostResultsValue OCTET STRING,
|
|
switchModuleMemDiagEnableDisable INTEGER,
|
|
smCfgCtrlEnableDisable INTEGER,
|
|
smExtEthPortsEnableDisable INTEGER,
|
|
switchPingRequest INTEGER,
|
|
smCfgCtrlOnResetEnableDisable INTEGER,
|
|
smHealthState INTEGER,
|
|
smPMState INTEGER,
|
|
smPMCtrlEnableDisable INTEGER,
|
|
smIOCompatibility OCTET STRING
|
|
}
|
|
|
|
smControlIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module control table index."
|
|
::= { smControlEntry 1 }
|
|
|
|
switchModuleControlId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module numeric identifier."
|
|
::= { smControlEntry 2 }
|
|
|
|
smPostResultsAvailable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Describes whether the switch module POST diagnostic result
|
|
value contained in the smPostResultsValue is valid."
|
|
::= { smControlEntry 3 }
|
|
|
|
smPostResultsValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The range of values and meanings are as follows:
|
|
0x00 - 0x7F ( 0 - 127) Base internal functions
|
|
0x80 - 0x9F (128 - 159) Internal interface failures
|
|
0xA0 - 0xAF (160 - 175) External interface failures
|
|
0xB0 - 0xFE (176 - 254) Reserved
|
|
0xFF (255) Switch completed POST successfully"
|
|
::= { smControlEntry 4 }
|
|
|
|
switchModuleMemDiagEnableDisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(0),
|
|
disabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module memory diagnostics enabled or disabled.
|
|
|
|
NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional
|
|
(i.e. - 0 and 1 are swapped), however, they cannot be changed since this MIB is already
|
|
published. "
|
|
::= { smControlEntry 5 }
|
|
|
|
smCfgCtrlEnableDisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module configuration control. When set to enabled, only the MM can manage
|
|
the module.
|
|
This MIB object can not be set, if AMM grants switch module the Protected Mode permission.
|
|
This MIB object can not be set, if the switch module is participating in the Stacking Mode
|
|
and external management is protected.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode. A value of disabled(0) will be returned."
|
|
::= { smControlEntry 6 }
|
|
|
|
smExtEthPortsEnableDisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module external ethernet ports enabled or disabled.
|
|
This MIB object can not be set, if AMM grants switch module the
|
|
Protected Mode permission.
|
|
This MIB object can not be set, if the switch module is participating
|
|
in the Stacking Mode and External Port Access is protected."
|
|
::= { smControlEntry 7 }
|
|
|
|
switchPingRequest OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Sends a ping to a switch module's current IPv4 address.
|
|
This MIB object can not be set, if AMM grants switch module the Protected Mode
|
|
permission and switch module goes into Protected Mode.
|
|
This MIB object can not be set, if the switch module is participating
|
|
in the Stacking Mode and IP Configuration is protected.
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object.
|
|
|
|
NOTE: This object has been deprecated in favor of the new
|
|
table smPingTable which supports IPv6 and IPv4 addresses."
|
|
::= { smControlEntry 8 }
|
|
|
|
smCfgCtrlOnResetEnableDisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(0),
|
|
disabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module configuration control on resets (default and unsolicited).
|
|
When set to enabled, the factory default IP configuration will become
|
|
active when the I/O module is reset to factory defaults by either the
|
|
management module or the I/O module. If an I/O module reset is initiated
|
|
by a source other than the management module then the previous IP configuration
|
|
will be in affect. In both these cases the MM will lose IP communications with
|
|
the IOM.
|
|
This MIB object can not be set, if AMM grants switch module the Protected Mode
|
|
permission and switch module goes into Protected Mode.
|
|
|
|
NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional
|
|
(i.e. - 0 and 1 are swapped), however, they cannot be changed since this MIB is already
|
|
published.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode. A value of disabled(1) will be returned."
|
|
::= { smControlEntry 9 }
|
|
|
|
smHealthState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
bad(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The health state for the switch module.
|
|
0 = unknown, 1 = good, 2 = warning, 3 = bad."
|
|
::= { smControlEntry 15}
|
|
|
|
smPMState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
pending(1),
|
|
attention(2),
|
|
active(3),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Protected Mode Status for the switch module.
|
|
standby- Protected Mode capability exists on the IOM but has not
|
|
been activated on the switch module or the AMM.
|
|
pending - Protected Mode has been activated on the AMM but not yet on the switch module.
|
|
active - Protected Mode is active on both the switch module and the AMM.
|
|
attention - Protected Mode is enabled on the switch module but not on the AMM."
|
|
::= { smControlEntry 16}
|
|
|
|
smPMCtrlEnableDisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"AMM Protected Mode permission for the switch module.
|
|
disabled - allow AMM to disable Protected Mode Permission for the switch module.
|
|
enabled - allow AMM to grant Protected Mode Permission for the switch module."
|
|
::= { smControlEntry 17}
|
|
|
|
smIOCompatibility OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The compatibility status for the I/O module.
|
|
|
|
The possible values and their meanings are as follows:
|
|
Unknown: This indicates a communication error for the I/O module.
|
|
OK: This is the normal (good) case where there are no compatibility
|
|
issues between the I/O module and the modules it is internally wired to.
|
|
No Fabric: This means the other end is not populated on any of the
|
|
modules this I/O module is internally wired to (e.g. this is an
|
|
Infiniband switch but none of the blades it is internally wired to
|
|
has an expansion card attached in the corresponding expansion slot).
|
|
Attention: Indicates one of the following cases:
|
|
One or more of the modules this I/O module is internally wired to is in communication error
|
|
The I/O module is powered off and at least one module it is internally wired to is powered on
|
|
Mismatch: Indicates one of the following cases:
|
|
Fabric types are incompatible
|
|
An unknown I/O module type
|
|
An unknown fabric type on a module the I/O module is internally wired to."
|
|
::= { smControlEntry 18}
|
|
|
|
smPingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmPingEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows pinging one of the active assigned addresses of an I/O module.
|
|
|
|
NOTE: This table is not applicable to modules that are running in
|
|
Stacking Mode and IP configuration is protected."
|
|
::= { switchModuleControl 2 }
|
|
|
|
smPingEntry OBJECT-TYPE
|
|
SYNTAX SmPingEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Represents a single address that can be pinged"
|
|
INDEX { smPingIndex, smPingAddressEntryIndex }
|
|
::= { smPingTable 1 }
|
|
|
|
SmPingEntry ::= SEQUENCE {
|
|
smPingIndex INTEGER,
|
|
smPingAddressEntryIndex INTEGER,
|
|
smPingAddress OCTET STRING,
|
|
smPingAddressExecute INTEGER
|
|
}
|
|
|
|
smPingIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module's slot number"
|
|
::= { smPingEntry 1 }
|
|
smPingAddressEntryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module's address entry index"
|
|
::= { smPingEntry 2 }
|
|
smPingAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module's IPv4 or IPv6 address"
|
|
::= { smPingEntry 3 }
|
|
smPingAddressExecute OBJECT-TYPE
|
|
SYNTAX INTEGER { execute(1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pings the given IP address.
|
|
|
|
NOTE: The GET operation for this object is meaningless."
|
|
::= { smPingEntry 4 }
|
|
|
|
smPowerRestartTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmPowerRestartEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module power restart table."
|
|
::= { switchModuleControl 7 }
|
|
|
|
smPowerRestartEntry OBJECT-TYPE
|
|
SYNTAX SmPowerRestartEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module power restart table entry"
|
|
INDEX { smPowerRestartIndex }
|
|
::= { smPowerRestartTable 1 }
|
|
|
|
SmPowerRestartEntry ::= SEQUENCE {
|
|
smPowerRestartIndex INTEGER,
|
|
smPowerRestartId INTEGER,
|
|
smSwitchExists INTEGER,
|
|
smSwitchType INTEGER,
|
|
smMACAddress OCTET STRING,
|
|
smIPAddress IpAddress,
|
|
switchModulePowerOnOff INTEGER,
|
|
smReset INTEGER,
|
|
smResetToDefault INTEGER,
|
|
smRestartAndRunStdDiag INTEGER,
|
|
smRestartAndRunExtDiag INTEGER,
|
|
smRestartAndRunFullDiag INTEGER,
|
|
smSwitchSubType INTEGER,
|
|
smSwitchWidth INTEGER,
|
|
smManufacturingID OCTET STRING,
|
|
smStackingModeState INTEGER,
|
|
smStackingModeInfo OCTET STRING
|
|
}
|
|
|
|
smPowerRestartIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module power restart index."
|
|
::= { smPowerRestartEntry 1 }
|
|
|
|
smPowerRestartId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module numeric identifier."
|
|
::= { smPowerRestartEntry 2 }
|
|
|
|
smSwitchExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module specified exists or not."
|
|
::= { smPowerRestartEntry 3 }
|
|
|
|
smSwitchType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
ethernet(1),
|
|
fibre(2),
|
|
opm(3),
|
|
serialCM(4),
|
|
copperPassThrough(5),
|
|
infiniband(6),
|
|
highSpeed(20),
|
|
passThrough(30),
|
|
sas(40)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module type."
|
|
::= { smPowerRestartEntry 4 }
|
|
|
|
smMACAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module MAC address."
|
|
::= { smPowerRestartEntry 5 }
|
|
|
|
smIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module current IP address.
|
|
If the switch module is participating in the Stacking Mode
|
|
and IP Configuration is protected, then the stack management
|
|
IP address is displayed.
|
|
|
|
NOTE: IPv6 addresses for the switch can be view with the
|
|
smIPv6AddressTable."
|
|
::= { smPowerRestartEntry 6 }
|
|
|
|
switchModulePowerOnOff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
poweroff(0),
|
|
poweron(1),
|
|
shutdownInProgress(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"I/O Module power on or power off. If powering on a currently
|
|
powered off I/O Module, then the I/O Module will execute a POST.
|
|
The results of this POST will need to be retrieved using the 'Post Results'
|
|
command.
|
|
NOTE:
|
|
When powering off a currently powered on I/O Module, a minimum of 1 second
|
|
is needed to allow the module to power off before powering back on.
|
|
The value 'shutdownInProgress' is for I/O Modules that may take some time to
|
|
transition from 'poweron' to 'poweroff'. For example, SAS Controller Modules must
|
|
flush pending I/O before powering off in order to maintain data integrity.
|
|
The value'shutdownInProgress' can not be used to set.
|
|
If both SAS Controller Module and SAS Connectivity Module are installed in slot 3
|
|
and 4 of BCS chassis, AMM must prevent one of them from powering on otherwise
|
|
there would be conflict with the Storage Module access and possibly corruption of data.
|
|
This MIB object can not be set, if AMM grants the I/O Module the Protected Mode
|
|
permission and module goes into Protected Mode."
|
|
::= { smPowerRestartEntry 7 }
|
|
|
|
smReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the case where the switch module is currently powered on, this command
|
|
will effectively power off and then power on the switch module indicated and
|
|
cause it to run its POST test. For the case where the switch module is
|
|
currently powered off, the command will just power on the switch module.
|
|
This MIB object can not be set, if AMM grants switch module the Protected Mode
|
|
permission and switch module goes into Protected Mode.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { smPowerRestartEntry 8 }
|
|
|
|
smResetToDefault OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For the case where the switch module is currently powered on, this command
|
|
will effectively power off and then power on the switch module indicated and
|
|
cause it to run its POST test. For the case where the switch module is
|
|
currently powered off, the command will just power on the switch module.
|
|
In both cases, the switch module will reset the configuration to the default
|
|
values.
|
|
This MIB object can not be set, if AMM grants switch module the Protected Mode
|
|
permission and switch module goes into Protected Mode.
|
|
This MIB object can not be set, if the switch module is participating in the
|
|
Stacking Mode and reset to default is protected.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { smPowerRestartEntry 9 }
|
|
|
|
smRestartAndRunStdDiag OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To power cycle the selected module(s) and then run the standard diagnostic
|
|
test package.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { smPowerRestartEntry 10 }
|
|
|
|
smRestartAndRunExtDiag OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To power cycle the selected module(s) and then run the extended diagnostic
|
|
test package. This option is not supported on all I/O modules.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { smPowerRestartEntry 11 }
|
|
|
|
smRestartAndRunFullDiag OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To power cycle the selected module(s) and then run the full diagnostic test
|
|
package. The full diagnostic test package may take over 5 minutes to run.
|
|
This option is not supported on all I/O modules.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { smPowerRestartEntry 12 }
|
|
|
|
smSwitchSubType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
ethernet(1),
|
|
fibre(2),
|
|
infiniband(6),
|
|
sas(7),
|
|
raidsas(8),
|
|
icpm(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module subtype.
|
|
NOTE: Some Legacy modules do not support a subtype and will be displayed as unknown."
|
|
::= { smPowerRestartEntry 20 }
|
|
|
|
smSwitchWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module width."
|
|
::= { smPowerRestartEntry 21 }
|
|
|
|
smManufacturingID OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module hardware VPD manufacturing ID."
|
|
::= { smPowerRestartEntry 22 }
|
|
|
|
smStackingModeState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standby(0),
|
|
member(1),
|
|
master(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Stacking Mode Status for the switch module.
|
|
standby - I/O module has stacking capability but is not part of a stack.
|
|
member - I/O module has stacking capability and is part of a stack in the
|
|
member role.
|
|
master - I/O module has stacking capability and is part of a stack in the
|
|
master role.
|
|
NOTE: The term disabled was changed to the term standby to be more descriptive."
|
|
::= { smPowerRestartEntry 23 }
|
|
|
|
smStackingModeInfo OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string containing a text description about the details of which functions are
|
|
protected for a switch module when it is in Stacking Mode as Master or Member.
|
|
The possible functions protected by switch modules are IP configuration,
|
|
External Port Access, External Management all over ports and Restore to defaults."
|
|
::= { smPowerRestartEntry 24 }
|
|
|
|
smIOCompatibilityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmIOCompatibilityEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module control table."
|
|
::= { switchModuleControl 10 }
|
|
|
|
smIOCompatibilityEntry OBJECT-TYPE
|
|
SYNTAX SmIOCompatibilityEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module IO compatibility table entry"
|
|
INDEX { smIOCompatibilityIndex }
|
|
::= { smIOCompatibilityTable 1 }
|
|
|
|
SmIOCompatibilityEntry ::= SEQUENCE {
|
|
smIOCompatibilityIndex INTEGER,
|
|
smIOCompatibilityId INTEGER,
|
|
smIOCompatibilityModuleBay OCTET STRING,
|
|
smIOCompatibilityModulePower OCTET STRING,
|
|
smIOCompatibilityModuleFabricType OCTET STRING,
|
|
smIOCompatibilityStatus OCTET STRING
|
|
}
|
|
|
|
smIOCompatibilityIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module IO compatibility index."
|
|
::= { smIOCompatibilityEntry 1 }
|
|
|
|
smIOCompatibilityId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module numeric identifier."
|
|
::= { smIOCompatibilityEntry 2 }
|
|
|
|
smIOCompatibilityModuleBay OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The modules (each one specified by module type and bay number) that
|
|
this I/O module can communicate with over the midplane networking fabric
|
|
(i.e. a physical path exists between the I/O module and this module)."
|
|
::= { smIOCompatibilityEntry 3 }
|
|
|
|
smIOCompatibilityModulePower OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power state of the module specified in smIOCompatibilityModuleBay."
|
|
::= { smIOCompatibilityEntry 4 }
|
|
|
|
smIOCompatibilityModuleFabricType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The I/O fabric type on the module side for the module.
|
|
'n/a' will be displayed if the corresponding channel is not populated
|
|
on the module side (e.g. we are looking at the details for an Infiniband
|
|
switch but the blade does not have an Infiniband expansion card attached
|
|
in the corresponding expansion slot)."
|
|
::= { smIOCompatibilityEntry 5 }
|
|
|
|
smIOCompatibilityStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The compatibility status for this I/O module and the module specified
|
|
in smIOCompatibilityModuleBay.
|
|
|
|
The possible values are:
|
|
OK: No compatibility issues
|
|
n/a: Indicates the corresponding channel is not populated on the module
|
|
side even though the module is present (e.g. we are looking at the details
|
|
for an Infiniband switch but the blade specified in smIOCompatibilityModuleBay
|
|
does not have an Infiniband expansion card attached in the corresponding expansion slot).
|
|
Attention: Indicates one of the following:
|
|
The module specified in smIOCompatibilityModuleBay has a communication error.
|
|
The I/O module is powered off but the module specified in smIOCompatibilityModuleBay is powered on.
|
|
Mismatch: Indicates one of the following cases::
|
|
Fabric types are incompatible
|
|
Unknown fabric type on the module side
|
|
Unknown I/O module type"
|
|
::= { smIOCompatibilityEntry 6 }
|
|
|
|
-- ********************************************************************************
|
|
-- Switch module config
|
|
-- ********************************************************************************
|
|
switchModuleConfig OBJECT IDENTIFIER ::= { switchModule 2 }
|
|
-- Server blade switch module configuration
|
|
|
|
switchMgmtNetworkCfg OBJECT IDENTIFIER ::= { switchModuleConfig 1 }
|
|
-- Server blade switch module management network config
|
|
|
|
--
|
|
-- Current switch module network config
|
|
--
|
|
switchCurrentNwCfg OBJECT IDENTIFIER ::= { switchMgmtNetworkCfg 1 }
|
|
-- Server blade switch module current network config
|
|
|
|
smCurrentIPInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmCurrentIPInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module current IP information.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in
|
|
Stacking Mode and IP configuration is protected."
|
|
::= { switchCurrentNwCfg 1 }
|
|
|
|
smCurrentIPInfoEntry OBJECT-TYPE
|
|
SYNTAX SmCurrentIPInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module current IP table entry.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in
|
|
Stacking Mode and IP configuration is protected."
|
|
INDEX { smCurrentIPInfoIndex }
|
|
::= { smCurrentIPInfoTable 1 }
|
|
|
|
SmCurrentIPInfoEntry ::= SEQUENCE {
|
|
smCurrentIPInfoIndex INTEGER,
|
|
smCurrentIPInfoId INTEGER,
|
|
smCurrentIPInfoExists INTEGER,
|
|
smCurrentIPInfoPowerState INTEGER,
|
|
smCurrentIPAddr IpAddress,
|
|
smCurrentSubnetMask IpAddress,
|
|
smCurrentGateway IpAddress,
|
|
smCurrentIPConfigMethod INTEGER
|
|
}
|
|
|
|
smCurrentIPInfoIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module current IP info index.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in
|
|
Stacking Mode and IP configuration is protected."
|
|
::= { smCurrentIPInfoEntry 1 }
|
|
|
|
smCurrentIPInfoId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module numeric identifier.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in
|
|
Stacking Mode and IP configuration is protected."
|
|
::= { smCurrentIPInfoEntry 2 }
|
|
|
|
smCurrentIPInfoExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module specified exists or not.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in
|
|
Stacking Mode and IP configuration is protected."
|
|
::= { smCurrentIPInfoEntry 3 }
|
|
|
|
smCurrentIPInfoPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
shutdownInProgress(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the I/O Module specified is powered on or not.
|
|
The value 'shutdownInProgress' is for the I/O Module that may take some time to
|
|
transition from 'poweron' to 'poweroff'. Such as SAS Controller Modules, that must
|
|
flush pending I/O before powering off in order to maintain data integrity.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in
|
|
Stacking Mode and IP configuration is protected."
|
|
::= { smCurrentIPInfoEntry 4 }
|
|
|
|
smCurrentIPAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module current IP address.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in
|
|
Stacking Mode and IP configuration is protected."
|
|
::= { smCurrentIPInfoEntry 6 }
|
|
|
|
|
|
smCurrentSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module current subnet mask.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in
|
|
Stacking Mode and IP configuration is protected."
|
|
::= { smCurrentIPInfoEntry 7 }
|
|
|
|
smCurrentGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module current IP gateway.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in
|
|
Stacking Mode and IP configuration is protected."
|
|
::= { smCurrentIPInfoEntry 8 }
|
|
|
|
smCurrentIPConfigMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
static(1),
|
|
dhcp(2),
|
|
nat (3),
|
|
bootp(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module current IP configuration method.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in
|
|
Stacking Mode and IP configuration is protected."
|
|
::= { smCurrentIPInfoEntry 9 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- New switch module network config
|
|
-- ********************************************************************************
|
|
switchNewNwCfg OBJECT IDENTIFIER ::= { switchMgmtNetworkCfg 2 }
|
|
-- Server blade switch module new network config
|
|
|
|
smNewIPInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmNewIPInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module new IP information.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode or Stacking Mode and IP configuration is protected."
|
|
::= { switchNewNwCfg 1 }
|
|
|
|
smNewIPInfoEntry OBJECT-TYPE
|
|
SYNTAX SmNewIPInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module new IP configuration information table entry.
|
|
|
|
NOTE: This MIB table is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode or Stacking Mode and IP configuration is protected."
|
|
INDEX { smNewIPInfoIndex }
|
|
::= { smNewIPInfoTable 1 }
|
|
|
|
SmNewIPInfoEntry ::= SEQUENCE {
|
|
smNewIPInfoIndex INTEGER,
|
|
smNewIPInfoId INTEGER,
|
|
smNewIPInfoExists INTEGER,
|
|
smNewIPInfoPowerState INTEGER,
|
|
smNewIPAddr IpAddress,
|
|
smNewSubnetMask IpAddress,
|
|
smNewGateway IpAddress,
|
|
smNewIPConfigMethod INTEGER,
|
|
smNewIPConfigEnableDisable INTEGER
|
|
}
|
|
|
|
smNewIPInfoIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module new IP info index.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode or Stacking Mode and IP configuration is protected."
|
|
::= { smNewIPInfoEntry 1 }
|
|
|
|
smNewIPInfoId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module numeric identifier.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode or Stacking Mode and IP configuration is protected."
|
|
::= { smNewIPInfoEntry 2 }
|
|
|
|
smNewIPInfoExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module specified exists or not.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode or Stacking Mode and IP configuration is protected."
|
|
::= { smNewIPInfoEntry 3 }
|
|
|
|
smNewIPInfoPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module specified is powered on or not.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode or Stacking Mode and IP configuration is protected.."
|
|
::= { smNewIPInfoEntry 4 }
|
|
|
|
smNewIPAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module new IP address. Before setting this object to a new value,
|
|
smNewIpconfigEnableDisable object must first be set to disabled.
|
|
NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode
|
|
permission and the switch module goes into Protected Mode.
|
|
NOTE: This MIB object can not be set if the switch module is in Stacking Mode
|
|
and IP Configuration is protected.
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode."
|
|
::= { smNewIPInfoEntry 6 }
|
|
|
|
|
|
smNewSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module new subnet mask. Before setting this object to a new value,
|
|
smNewIpconfigEnableDisable object must first be set to disabled.
|
|
NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode
|
|
permission and the switch module goes into Protected Mode.
|
|
NOTE: This MIB object can not be set if the switch module is in Stacking Mode,
|
|
and IP Configuration is protected.
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode."
|
|
::= { smNewIPInfoEntry 7 }
|
|
|
|
smNewGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module new IP gateway. Before setting this object to a new value,
|
|
smNewIpconfigEnableDisable object must first be set to disabled.
|
|
NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode
|
|
permission and the switch module goes into Protected Mode.
|
|
NOTE: This MIB object can not be set if the switch module is in Stacking Mode,
|
|
and IP Configuration is protected.
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode."
|
|
::= { smNewIPInfoEntry 8 }
|
|
|
|
smNewIPConfigMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
static(1),
|
|
dhcp(2),
|
|
nat(3),
|
|
bootp(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module new IP configuration method. Before setting this object to a new value,
|
|
smNewIpconfigEnableDisable object must first be set to disabled.
|
|
NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode
|
|
permission and the switch module goes into Protected Mode.
|
|
NOTE: This MIB object can not be set if the switch module is in Stacking Mode,
|
|
and IP Configuration is protected.
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode."
|
|
::= { smNewIPInfoEntry 9 }
|
|
|
|
smNewIPConfigEnableDisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A set command enables a new IP configuration that has been
|
|
previously defined. A get command indicates whether the new
|
|
IP configuration information has been enabled.
|
|
NOTE: This MIB object can not be set if the AMM grants the switch module Protected Mode
|
|
permission and the switch module goes into Protected Mode.
|
|
NOTE: This MIB object can not be set if the switch module is in Stacking Mode,
|
|
and IP Configuration is protected.
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode."
|
|
::= { smNewIPInfoEntry 10 }
|
|
|
|
-- ********************************************************************************
|
|
-- Network protocol (Network Address Translation) config
|
|
-- ********************************************************************************
|
|
switchNwProtCfg OBJECT IDENTIFIER ::= { switchMgmtNetworkCfg 3 }
|
|
|
|
switchNwProtCfgModOne OBJECT IDENTIFIER ::= { switchNwProtCfg 1 }
|
|
|
|
smNwProtInfoModOneTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmNwProtInfoModOneEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 1 network protocol (Network Address Translation) information."
|
|
::= { switchNwProtCfgModOne 1 }
|
|
|
|
smNwProtInfoModOneEntry OBJECT-TYPE
|
|
SYNTAX SmNwProtInfoModOneEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 1 network protocol (Network Address Translation) configuration
|
|
information table entry"
|
|
INDEX { smNwProtInfoModOneIndex }
|
|
::= { smNwProtInfoModOneTable 1 }
|
|
|
|
SmNwProtInfoModOneEntry ::= SEQUENCE {
|
|
smNwProtInfoModOneIndex INTEGER,
|
|
smNwProtInfoModOneId INTEGER,
|
|
smNwProtInfoModOneExists INTEGER,
|
|
smNwProtInfoModOnePowerState INTEGER,
|
|
smNwProtInfoModOneProtName OCTET STRING,
|
|
smNwProtInfoModOneProtID INTEGER,
|
|
smNwProtInfoModOneExtPort INTEGER,
|
|
smNwProtInfoModOneIntPort INTEGER,
|
|
smNwProtInfoModOneEnable INTEGER
|
|
}
|
|
|
|
smNwProtInfoModOneIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 1 network protocol (Network Address Translation) information index."
|
|
::= { smNwProtInfoModOneEntry 1 }
|
|
|
|
smNwProtInfoModOneId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module 1 numeric identifier."
|
|
::= { smNwProtInfoModOneEntry 2 }
|
|
|
|
smNwProtInfoModOneExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 1 exists or not."
|
|
::= { smNwProtInfoModOneEntry 3 }
|
|
|
|
smNwProtInfoModOnePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 1 is powered on or not."
|
|
::= { smNwProtInfoModOneEntry 4 }
|
|
|
|
smNwProtInfoModOneProtName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol name"
|
|
::= { smNwProtInfoModOneEntry 5 }
|
|
|
|
smNwProtInfoModOneProtID OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- ip(1),
|
|
tcp(2),
|
|
udp(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol ID"
|
|
::= { smNwProtInfoModOneEntry 6 }
|
|
|
|
smNwProtInfoModOneExtPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External port"
|
|
::= { smNwProtInfoModOneEntry 7 }
|
|
|
|
smNwProtInfoModOneIntPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Internal port."
|
|
::= { smNwProtInfoModOneEntry 8 }
|
|
|
|
smNwProtInfoModOneEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the protocol entry."
|
|
::= { smNwProtInfoModOneEntry 9 }
|
|
|
|
smNwProtInfoModOneActivate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Activate all network protocol settings for the switch module.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModOne 2 }
|
|
|
|
smNwProtInfoModOneReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset all network protocol settings for the switch module to default.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModOne 3 }
|
|
|
|
|
|
switchNwProtCfgModTwo OBJECT IDENTIFIER ::= { switchNwProtCfg 2 }
|
|
|
|
smNwProtInfoModTwoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmNwProtInfoModTwoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 2 network protocol (Network Address Translation) information."
|
|
::= { switchNwProtCfgModTwo 1 }
|
|
|
|
smNwProtInfoModTwoEntry OBJECT-TYPE
|
|
SYNTAX SmNwProtInfoModTwoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 2 network protocol (Network Address Translation) configuration
|
|
information table entry"
|
|
INDEX { smNwProtInfoModTwoIndex }
|
|
::= { smNwProtInfoModTwoTable 1 }
|
|
|
|
SmNwProtInfoModTwoEntry ::= SEQUENCE {
|
|
smNwProtInfoModTwoIndex INTEGER,
|
|
smNwProtInfoModTwoId INTEGER,
|
|
smNwProtInfoModTwoExists INTEGER,
|
|
smNwProtInfoModTwoPowerState INTEGER,
|
|
smNwProtInfoModTwoProtName OCTET STRING,
|
|
smNwProtInfoModTwoProtID INTEGER,
|
|
smNwProtInfoModTwoExtPort INTEGER,
|
|
smNwProtInfoModTwoIntPort INTEGER,
|
|
smNwProtInfoModTwoEnable INTEGER
|
|
}
|
|
|
|
smNwProtInfoModTwoIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 2 network protocol (Network Address Translation) information index."
|
|
::= { smNwProtInfoModTwoEntry 1 }
|
|
|
|
smNwProtInfoModTwoId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module 2 numeric identifier."
|
|
::= { smNwProtInfoModTwoEntry 2 }
|
|
|
|
smNwProtInfoModTwoExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 2 exists or not."
|
|
::= { smNwProtInfoModTwoEntry 3 }
|
|
|
|
smNwProtInfoModTwoPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 2 is powered on or not."
|
|
::= { smNwProtInfoModTwoEntry 4 }
|
|
|
|
smNwProtInfoModTwoProtName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol name"
|
|
::= { smNwProtInfoModTwoEntry 5 }
|
|
|
|
smNwProtInfoModTwoProtID OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tcp(2),
|
|
udp(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol ID"
|
|
::= { smNwProtInfoModTwoEntry 6 }
|
|
|
|
smNwProtInfoModTwoExtPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External port"
|
|
::= { smNwProtInfoModTwoEntry 7 }
|
|
|
|
smNwProtInfoModTwoIntPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Internal port."
|
|
::= { smNwProtInfoModTwoEntry 8 }
|
|
|
|
smNwProtInfoModTwoEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the protocol entry."
|
|
::= { smNwProtInfoModTwoEntry 9 }
|
|
|
|
smNwProtInfoModTwoActivate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Activate all network protocol settings for the switch module.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModTwo 2 }
|
|
|
|
smNwProtInfoModTwoReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset all network protocol settings for the switch module to default.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModTwo 3 }
|
|
|
|
|
|
switchNwProtCfgModThree OBJECT IDENTIFIER ::= { switchNwProtCfg 3 }
|
|
|
|
smNwProtInfoModThreeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmNwProtInfoModThreeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 3 network protocol (Network Address Translation) information."
|
|
::= { switchNwProtCfgModThree 1 }
|
|
|
|
smNwProtInfoModThreeEntry OBJECT-TYPE
|
|
SYNTAX SmNwProtInfoModThreeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 3 network protocol (Network Address Translation) configuration
|
|
information table entry"
|
|
INDEX { smNwProtInfoModThreeIndex }
|
|
::= { smNwProtInfoModThreeTable 1 }
|
|
|
|
SmNwProtInfoModThreeEntry ::= SEQUENCE {
|
|
smNwProtInfoModThreeIndex INTEGER,
|
|
smNwProtInfoModThreeId INTEGER,
|
|
smNwProtInfoModThreeExists INTEGER,
|
|
smNwProtInfoModThreePowerState INTEGER,
|
|
smNwProtInfoModThreeProtName OCTET STRING,
|
|
smNwProtInfoModThreeProtID INTEGER,
|
|
smNwProtInfoModThreeExtPort INTEGER,
|
|
smNwProtInfoModThreeIntPort INTEGER,
|
|
smNwProtInfoModThreeEnable INTEGER
|
|
}
|
|
|
|
smNwProtInfoModThreeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 3 network protocol (Network Address Translation) information index."
|
|
::= { smNwProtInfoModThreeEntry 1 }
|
|
|
|
smNwProtInfoModThreeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module 3 numeric identifier."
|
|
::= { smNwProtInfoModThreeEntry 2 }
|
|
|
|
smNwProtInfoModThreeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 3 exists or not."
|
|
::= { smNwProtInfoModThreeEntry 3 }
|
|
|
|
smNwProtInfoModThreePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 3 is powered on or not."
|
|
::= { smNwProtInfoModThreeEntry 4 }
|
|
|
|
smNwProtInfoModThreeProtName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol name"
|
|
::= { smNwProtInfoModThreeEntry 5 }
|
|
|
|
smNwProtInfoModThreeProtID OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tcp(2),
|
|
udp(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol ID"
|
|
::= { smNwProtInfoModThreeEntry 6 }
|
|
|
|
smNwProtInfoModThreeExtPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External port"
|
|
::= { smNwProtInfoModThreeEntry 7 }
|
|
|
|
smNwProtInfoModThreeIntPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Internal port."
|
|
::= { smNwProtInfoModThreeEntry 8 }
|
|
|
|
smNwProtInfoModThreeEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the protocol entry."
|
|
::= { smNwProtInfoModThreeEntry 9 }
|
|
|
|
smNwProtInfoModThreeActivate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Activate all network protocol settings for the switch module.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModThree 2 }
|
|
|
|
smNwProtInfoModThreeReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset all network protocol settings for the switch module to default.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModThree 3 }
|
|
|
|
|
|
switchNwProtCfgModFour OBJECT IDENTIFIER ::= { switchNwProtCfg 4 }
|
|
|
|
smNwProtInfoModFourTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmNwProtInfoModFourEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 4 network protocol (Network Address Translation) information."
|
|
::= { switchNwProtCfgModFour 1 }
|
|
|
|
smNwProtInfoModFourEntry OBJECT-TYPE
|
|
SYNTAX SmNwProtInfoModFourEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 3 network protocol (Network Address Translation) configuration
|
|
information table entry."
|
|
INDEX { smNwProtInfoModFourIndex }
|
|
::= { smNwProtInfoModFourTable 1 }
|
|
|
|
SmNwProtInfoModFourEntry ::= SEQUENCE {
|
|
smNwProtInfoModFourIndex INTEGER,
|
|
smNwProtInfoModFourId INTEGER,
|
|
smNwProtInfoModFourExists INTEGER,
|
|
smNwProtInfoModFourPowerState INTEGER,
|
|
smNwProtInfoModFourProtName OCTET STRING,
|
|
smNwProtInfoModFourProtID INTEGER,
|
|
smNwProtInfoModFourExtPort INTEGER,
|
|
smNwProtInfoModFourIntPort INTEGER,
|
|
smNwProtInfoModFourEnable INTEGER
|
|
}
|
|
|
|
smNwProtInfoModFourIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 4 network protocol (Network Address Translation) information index."
|
|
::= { smNwProtInfoModFourEntry 1 }
|
|
|
|
smNwProtInfoModFourId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module 4 numeric identifier."
|
|
::= { smNwProtInfoModFourEntry 2 }
|
|
|
|
smNwProtInfoModFourExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 4 exists or not."
|
|
::= { smNwProtInfoModFourEntry 3 }
|
|
|
|
smNwProtInfoModFourPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 4 is powered on or not."
|
|
::= { smNwProtInfoModFourEntry 4 }
|
|
|
|
smNwProtInfoModFourProtName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol name"
|
|
::= { smNwProtInfoModFourEntry 5 }
|
|
|
|
smNwProtInfoModFourProtID OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tcp(2),
|
|
udp(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol ID"
|
|
::= { smNwProtInfoModFourEntry 6 }
|
|
|
|
smNwProtInfoModFourExtPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External port"
|
|
::= { smNwProtInfoModFourEntry 7 }
|
|
|
|
smNwProtInfoModFourIntPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Internal port."
|
|
::= { smNwProtInfoModFourEntry 8 }
|
|
|
|
smNwProtInfoModFourEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the protocol entry."
|
|
::= { smNwProtInfoModFourEntry 9 }
|
|
|
|
smNwProtInfoModFourActivate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Activate all network protocol settings for the switch module.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModFour 2 }
|
|
|
|
smNwProtInfoModFourReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset all network protocol settings for the switch module to default.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModFour 3 }
|
|
|
|
switchNwProtCfgModFive OBJECT IDENTIFIER ::= { switchNwProtCfg 5 }
|
|
|
|
smNwProtInfoModFiveTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmNwProtInfoModFiveEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 5 network protocol (Network Address Translation) information."
|
|
::= { switchNwProtCfgModFive 1 }
|
|
|
|
smNwProtInfoModFiveEntry OBJECT-TYPE
|
|
SYNTAX SmNwProtInfoModFiveEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 5 network protocol (Network Address Translation) configuration
|
|
information table entry"
|
|
INDEX { smNwProtInfoModFiveIndex }
|
|
::= { smNwProtInfoModFiveTable 1 }
|
|
|
|
SmNwProtInfoModFiveEntry ::= SEQUENCE {
|
|
smNwProtInfoModFiveIndex INTEGER,
|
|
smNwProtInfoModFiveId INTEGER,
|
|
smNwProtInfoModFiveExists INTEGER,
|
|
smNwProtInfoModFivePowerState INTEGER,
|
|
smNwProtInfoModFiveProtName OCTET STRING,
|
|
smNwProtInfoModFiveProtID INTEGER,
|
|
smNwProtInfoModFiveExtPort INTEGER,
|
|
smNwProtInfoModFiveIntPort INTEGER,
|
|
smNwProtInfoModFiveEnable INTEGER
|
|
}
|
|
|
|
smNwProtInfoModFiveIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 5 network protocol (Network Address Translation) information index."
|
|
::= { smNwProtInfoModFiveEntry 1 }
|
|
|
|
smNwProtInfoModFiveId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module 5 numeric identifier."
|
|
::= { smNwProtInfoModFiveEntry 2 }
|
|
|
|
smNwProtInfoModFiveExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 5 exists or not."
|
|
::= { smNwProtInfoModFiveEntry 3 }
|
|
|
|
smNwProtInfoModFivePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 5 is powered on or not."
|
|
::= { smNwProtInfoModFiveEntry 4 }
|
|
|
|
smNwProtInfoModFiveProtName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol name"
|
|
::= { smNwProtInfoModFiveEntry 5 }
|
|
|
|
smNwProtInfoModFiveProtID OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tcp(2),
|
|
udp(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol ID"
|
|
::= { smNwProtInfoModFiveEntry 6 }
|
|
|
|
smNwProtInfoModFiveExtPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External port"
|
|
::= { smNwProtInfoModFiveEntry 7 }
|
|
|
|
smNwProtInfoModFiveIntPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Internal port."
|
|
::= { smNwProtInfoModFiveEntry 8 }
|
|
|
|
smNwProtInfoModFiveEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the protocol entry."
|
|
::= { smNwProtInfoModFiveEntry 9 }
|
|
|
|
smNwProtInfoModFiveActivate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Activate all network protocol settings for the switch module.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModFive 2 }
|
|
|
|
smNwProtInfoModFiveReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset all network protocol settings for the switch module to default.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModFive 3 }
|
|
|
|
|
|
switchNwProtCfgModSix OBJECT IDENTIFIER ::= { switchNwProtCfg 6 }
|
|
|
|
smNwProtInfoModSixTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmNwProtInfoModSixEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 6 network protocol (Network Address Translation) information."
|
|
::= { switchNwProtCfgModSix 1 }
|
|
|
|
smNwProtInfoModSixEntry OBJECT-TYPE
|
|
SYNTAX SmNwProtInfoModSixEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 6 network protocol (Network Address Translation) configuration
|
|
information table entry"
|
|
INDEX { smNwProtInfoModSixIndex }
|
|
::= { smNwProtInfoModSixTable 1 }
|
|
|
|
SmNwProtInfoModSixEntry ::= SEQUENCE {
|
|
smNwProtInfoModSixIndex INTEGER,
|
|
smNwProtInfoModSixId INTEGER,
|
|
smNwProtInfoModSixExists INTEGER,
|
|
smNwProtInfoModSixPowerState INTEGER,
|
|
smNwProtInfoModSixProtName OCTET STRING,
|
|
smNwProtInfoModSixProtID INTEGER,
|
|
smNwProtInfoModSixExtPort INTEGER,
|
|
smNwProtInfoModSixIntPort INTEGER,
|
|
smNwProtInfoModSixEnable INTEGER
|
|
}
|
|
|
|
smNwProtInfoModSixIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 6 network protocol (Network Address Translation) information index."
|
|
::= { smNwProtInfoModSixEntry 1 }
|
|
|
|
smNwProtInfoModSixId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module 6 numeric identifier."
|
|
::= { smNwProtInfoModSixEntry 2 }
|
|
|
|
smNwProtInfoModSixExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 6 exists or not."
|
|
::= { smNwProtInfoModSixEntry 3 }
|
|
|
|
smNwProtInfoModSixPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 6 is powered on or not."
|
|
::= { smNwProtInfoModSixEntry 4 }
|
|
|
|
smNwProtInfoModSixProtName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol name"
|
|
::= { smNwProtInfoModSixEntry 5 }
|
|
|
|
smNwProtInfoModSixProtID OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tcp(2),
|
|
udp(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol ID"
|
|
::= { smNwProtInfoModSixEntry 6 }
|
|
|
|
smNwProtInfoModSixExtPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External port"
|
|
::= { smNwProtInfoModSixEntry 7 }
|
|
|
|
smNwProtInfoModSixIntPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Internal port."
|
|
::= { smNwProtInfoModSixEntry 8 }
|
|
|
|
smNwProtInfoModSixEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the protocol entry."
|
|
::= { smNwProtInfoModSixEntry 9 }
|
|
|
|
smNwProtInfoModSixActivate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Activate all network protocol settings for the switch module.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModSix 2 }
|
|
|
|
smNwProtInfoModSixReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset all network protocol settings for the switch module to default.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModSix 3 }
|
|
|
|
|
|
switchNwProtCfgModSeven OBJECT IDENTIFIER ::= { switchNwProtCfg 7 }
|
|
|
|
smNwProtInfoModSevenTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmNwProtInfoModSevenEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 7 network protocol (Network Address Translation) information."
|
|
::= { switchNwProtCfgModSeven 1 }
|
|
|
|
smNwProtInfoModSevenEntry OBJECT-TYPE
|
|
SYNTAX SmNwProtInfoModSevenEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 7 network protocol (Network Address Translation) configuration
|
|
information table entry"
|
|
INDEX { smNwProtInfoModSevenIndex }
|
|
::= { smNwProtInfoModSevenTable 1 }
|
|
|
|
SmNwProtInfoModSevenEntry ::= SEQUENCE {
|
|
smNwProtInfoModSevenIndex INTEGER,
|
|
smNwProtInfoModSevenId INTEGER,
|
|
smNwProtInfoModSevenExists INTEGER,
|
|
smNwProtInfoModSevenPowerState INTEGER,
|
|
smNwProtInfoModSevenProtName OCTET STRING,
|
|
smNwProtInfoModSevenProtID INTEGER,
|
|
smNwProtInfoModSevenExtPort INTEGER,
|
|
smNwProtInfoModSevenIntPort INTEGER,
|
|
smNwProtInfoModSevenEnable INTEGER
|
|
}
|
|
|
|
smNwProtInfoModSevenIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 7 network protocol (Network Address Translation) information index."
|
|
::= { smNwProtInfoModSevenEntry 1 }
|
|
|
|
smNwProtInfoModSevenId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module 7 numeric identifier."
|
|
::= { smNwProtInfoModSevenEntry 2 }
|
|
|
|
smNwProtInfoModSevenExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 7 exists or not."
|
|
::= { smNwProtInfoModSevenEntry 3 }
|
|
|
|
smNwProtInfoModSevenPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 7 is powered on or not."
|
|
::= { smNwProtInfoModSevenEntry 4 }
|
|
|
|
smNwProtInfoModSevenProtName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol name"
|
|
::= { smNwProtInfoModSevenEntry 5 }
|
|
|
|
smNwProtInfoModSevenProtID OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tcp(2),
|
|
udp(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol ID"
|
|
::= { smNwProtInfoModSevenEntry 6 }
|
|
|
|
smNwProtInfoModSevenExtPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External port"
|
|
::= { smNwProtInfoModSevenEntry 7 }
|
|
|
|
smNwProtInfoModSevenIntPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Internal port."
|
|
::= { smNwProtInfoModSevenEntry 8 }
|
|
|
|
smNwProtInfoModSevenEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the protocol entry."
|
|
::= { smNwProtInfoModSevenEntry 9 }
|
|
|
|
smNwProtInfoModSevenActivate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Activate all network protocol settings for the switch module.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModSeven 2 }
|
|
|
|
smNwProtInfoModSevenReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset all network protocol settings for the switch module to default.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModSeven 3 }
|
|
|
|
|
|
switchNwProtCfgModEight OBJECT IDENTIFIER ::= { switchNwProtCfg 8 }
|
|
|
|
smNwProtInfoModEightTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmNwProtInfoModEightEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 8 network protocol (Network Address Translation) information."
|
|
::= { switchNwProtCfgModEight 1 }
|
|
|
|
smNwProtInfoModEightEntry OBJECT-TYPE
|
|
SYNTAX SmNwProtInfoModEightEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 8 network protocol (Network Address Translation) configuration
|
|
information table entry"
|
|
INDEX { smNwProtInfoModEightIndex }
|
|
::= { smNwProtInfoModEightTable 1 }
|
|
|
|
SmNwProtInfoModEightEntry ::= SEQUENCE {
|
|
smNwProtInfoModEightIndex INTEGER,
|
|
smNwProtInfoModEightId INTEGER,
|
|
smNwProtInfoModEightExists INTEGER,
|
|
smNwProtInfoModEightPowerState INTEGER,
|
|
smNwProtInfoModEightProtName OCTET STRING,
|
|
smNwProtInfoModEightProtID INTEGER,
|
|
smNwProtInfoModEightExtPort INTEGER,
|
|
smNwProtInfoModEightIntPort INTEGER,
|
|
smNwProtInfoModEightEnable INTEGER
|
|
}
|
|
|
|
smNwProtInfoModEightIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 8 network protocol (Network Address Translation) information index."
|
|
::= { smNwProtInfoModEightEntry 1 }
|
|
|
|
smNwProtInfoModEightId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module 8 numeric identifier."
|
|
::= { smNwProtInfoModEightEntry 2 }
|
|
|
|
smNwProtInfoModEightExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 8 exists or not."
|
|
::= { smNwProtInfoModEightEntry 3 }
|
|
|
|
smNwProtInfoModEightPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 8 is powered on or not."
|
|
::= { smNwProtInfoModEightEntry 4 }
|
|
|
|
smNwProtInfoModEightProtName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol name"
|
|
::= { smNwProtInfoModEightEntry 5 }
|
|
|
|
smNwProtInfoModEightProtID OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tcp(2),
|
|
udp(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol ID"
|
|
::= { smNwProtInfoModEightEntry 6 }
|
|
|
|
smNwProtInfoModEightExtPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External port"
|
|
::= { smNwProtInfoModEightEntry 7 }
|
|
|
|
smNwProtInfoModEightIntPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Internal port."
|
|
::= { smNwProtInfoModEightEntry 8 }
|
|
|
|
smNwProtInfoModEightEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the protocol entry."
|
|
::= { smNwProtInfoModEightEntry 9 }
|
|
|
|
smNwProtInfoModEightActivate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Activate all network protocol settings for the switch module.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModEight 2 }
|
|
|
|
smNwProtInfoModEightReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset all network protocol settings for the switch module to default.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModEight 3 }
|
|
|
|
switchNwProtCfgModNine OBJECT IDENTIFIER ::= { switchNwProtCfg 9 }
|
|
|
|
smNwProtInfoModNineTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmNwProtInfoModNineEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 9 network protocol (Network Address Translation) information."
|
|
::= { switchNwProtCfgModNine 1 }
|
|
|
|
smNwProtInfoModNineEntry OBJECT-TYPE
|
|
SYNTAX SmNwProtInfoModNineEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 9 network protocol (Network Address Translation) configuration
|
|
information table entry"
|
|
INDEX { smNwProtInfoModNineIndex }
|
|
::= { smNwProtInfoModNineTable 1 }
|
|
|
|
SmNwProtInfoModNineEntry ::= SEQUENCE {
|
|
smNwProtInfoModNineIndex INTEGER,
|
|
smNwProtInfoModNineId INTEGER,
|
|
smNwProtInfoModNineExists INTEGER,
|
|
smNwProtInfoModNinePowerState INTEGER,
|
|
smNwProtInfoModNineProtName OCTET STRING,
|
|
smNwProtInfoModNineProtID INTEGER,
|
|
smNwProtInfoModNineExtPort INTEGER,
|
|
smNwProtInfoModNineIntPort INTEGER,
|
|
smNwProtInfoModNineEnable INTEGER
|
|
}
|
|
|
|
smNwProtInfoModNineIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 9 network protocol (Network Address Translation) information index."
|
|
::= { smNwProtInfoModNineEntry 1 }
|
|
|
|
smNwProtInfoModNineId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module 9 numeric identifier."
|
|
::= { smNwProtInfoModNineEntry 2 }
|
|
|
|
smNwProtInfoModNineExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 9 exists or not."
|
|
::= { smNwProtInfoModNineEntry 3 }
|
|
|
|
smNwProtInfoModNinePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 9 is powered on or not."
|
|
::= { smNwProtInfoModNineEntry 4 }
|
|
|
|
smNwProtInfoModNineProtName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol name"
|
|
::= { smNwProtInfoModNineEntry 5 }
|
|
|
|
smNwProtInfoModNineProtID OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tcp(2),
|
|
udp(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol ID"
|
|
::= { smNwProtInfoModNineEntry 6 }
|
|
|
|
smNwProtInfoModNineExtPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External port"
|
|
::= { smNwProtInfoModNineEntry 7 }
|
|
|
|
smNwProtInfoModNineIntPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Internal port."
|
|
::= { smNwProtInfoModNineEntry 8 }
|
|
|
|
smNwProtInfoModNineEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the protocol entry."
|
|
::= { smNwProtInfoModNineEntry 9 }
|
|
|
|
smNwProtInfoModNineActivate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Activate all network protocol settings for the switch module.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModNine 2 }
|
|
|
|
smNwProtInfoModNineReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset all network protocol settings for the switch module to default.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModNine 3 }
|
|
|
|
switchNwProtCfgModTen OBJECT IDENTIFIER ::= { switchNwProtCfg 10 }
|
|
|
|
smNwProtInfoModTenTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmNwProtInfoModTenEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 10 network protocol (Network Address Translation) information."
|
|
::= { switchNwProtCfgModTen 1 }
|
|
|
|
smNwProtInfoModTenEntry OBJECT-TYPE
|
|
SYNTAX SmNwProtInfoModTenEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 10 network protocol (Network Address Translation) configuration
|
|
information table entry"
|
|
INDEX { smNwProtInfoModTenIndex }
|
|
::= { smNwProtInfoModTenTable 1 }
|
|
|
|
SmNwProtInfoModTenEntry ::= SEQUENCE {
|
|
smNwProtInfoModTenIndex INTEGER,
|
|
smNwProtInfoModTenId INTEGER,
|
|
smNwProtInfoModTenExists INTEGER,
|
|
smNwProtInfoModTenPowerState INTEGER,
|
|
smNwProtInfoModTenProtName OCTET STRING,
|
|
smNwProtInfoModTenProtID INTEGER,
|
|
smNwProtInfoModTenExtPort INTEGER,
|
|
smNwProtInfoModTenIntPort INTEGER,
|
|
smNwProtInfoModTenEnable INTEGER
|
|
}
|
|
|
|
smNwProtInfoModTenIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module 10 network protocol (Network Address Translation) information index."
|
|
::= { smNwProtInfoModTenEntry 1 }
|
|
|
|
smNwProtInfoModTenId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module1(1),
|
|
module2(2),
|
|
module3(3),
|
|
module4(4),
|
|
module5(5),
|
|
module6(6),
|
|
module7(7),
|
|
module8(8),
|
|
module9(9),
|
|
module10(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module 10 numeric identifier."
|
|
::= { smNwProtInfoModTenEntry 2 }
|
|
|
|
smNwProtInfoModTenExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 10 exists or not."
|
|
::= { smNwProtInfoModTenEntry 3 }
|
|
|
|
smNwProtInfoModTenPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the switch module 10 is powered on or not."
|
|
::= { smNwProtInfoModTenEntry 4 }
|
|
|
|
smNwProtInfoModTenProtName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol name"
|
|
::= { smNwProtInfoModTenEntry 5 }
|
|
|
|
smNwProtInfoModTenProtID OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tcp(2),
|
|
udp(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Protocol ID"
|
|
::= { smNwProtInfoModTenEntry 6 }
|
|
|
|
smNwProtInfoModTenExtPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External port"
|
|
::= { smNwProtInfoModTenEntry 7 }
|
|
|
|
smNwProtInfoModTenIntPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Internal port."
|
|
::= { smNwProtInfoModTenEntry 8 }
|
|
|
|
smNwProtInfoModTenEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the protocol entry."
|
|
::= { smNwProtInfoModTenEntry 9 }
|
|
|
|
smNwProtInfoModTenActivate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Activate all network protocol settings for the switch module.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModTen 2 }
|
|
|
|
smNwProtInfoModTenReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset all network protocol settings for the switch module to default.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { switchNwProtCfgModTen 3 }
|
|
|
|
switchIPv6Config OBJECT IDENTIFIER ::= { switchMgmtNetworkCfg 4 }
|
|
smIPv6ConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmIPv6ConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of IPv6 configuration options for switch modules.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in
|
|
Stacking Mode and IP configuration is protected.
|
|
|
|
NOTE: This MIB object is not applicable to modules that
|
|
do not support IPv6."
|
|
::= { switchIPv6Config 1 }
|
|
|
|
smIPv6ConfigEntry OBJECT-TYPE
|
|
SYNTAX SmIPv6ConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IPv6 configuration options for a switch module..
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in
|
|
Stacking Mode and IP configuration is protected.
|
|
|
|
NOTE: This MIB object is not applicable to modules that
|
|
do not support IPv6."
|
|
INDEX { smIPv6ConfigIndex }
|
|
::= { smIPv6ConfigTable 1 }
|
|
|
|
SmIPv6ConfigEntry ::= SEQUENCE {
|
|
smIPv6ConfigIndex INTEGER,
|
|
smIPv6ConfigEnabled INTEGER,
|
|
smIPv6ConfigStatic INTEGER,
|
|
smDHCPv6ConfigEnabled INTEGER,
|
|
smIPv6ConfigStatelessEnabled INTEGER
|
|
}
|
|
|
|
smIPv6ConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module's slot number"
|
|
::= { smIPv6ConfigEntry 1 }
|
|
smIPv6ConfigEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(0),enable(1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enables/Disables IPv6 support on the switch module."
|
|
::= { smIPv6ConfigEntry 2 }
|
|
smIPv6ConfigStatic OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(0),enable(1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enables/Disables IPv6 static configuration support on the switch module."
|
|
::= { smIPv6ConfigEntry 3 }
|
|
smDHCPv6ConfigEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(0),enable(1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enables/Disables DHCPv6 address configuration support on the switch module."
|
|
::= { smIPv6ConfigEntry 4 }
|
|
smIPv6ConfigStatelessEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(0),enable(1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enables/Disables IPv6 stateless auto-configuration support on the switch module."
|
|
::= { smIPv6ConfigEntry 5 }
|
|
|
|
smIPv6AddressTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmIPv6AddressEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of assigned IPv6 addresses for switch modules.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in
|
|
Stacking Mode and IP configuration is protected.
|
|
|
|
NOTE: This MIB object is not applicable to modules that
|
|
do not support IPv6."
|
|
::= { switchIPv6Config 2 }
|
|
|
|
smIPv6AddressEntry OBJECT-TYPE
|
|
SYNTAX SmIPv6AddressEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The assigned IPv6 address for a given switch module
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in
|
|
Stacking Mode and IP configuration is protected.
|
|
|
|
NOTE: This MIB object is not applicable to modules that
|
|
do not support IPv6."
|
|
INDEX { smIPv6AddressIndex, smIPv6AddressEntryIndex}
|
|
::= { smIPv6AddressTable 1 }
|
|
|
|
SmIPv6AddressEntry ::= SEQUENCE {
|
|
smIPv6AddressIndex INTEGER,
|
|
smIPv6AddressEntryIndex INTEGER,
|
|
smIPv6AddressType INTEGER,
|
|
smIPv6Address InetAddressIPv6,
|
|
smIPv6AddressPrefixLen INTEGER,
|
|
smIPv6AddressDefaultRoute InetAddressIPv6
|
|
}
|
|
|
|
smIPv6AddressIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module's slot number"
|
|
::= { smIPv6AddressEntry 1 }
|
|
smIPv6AddressEntryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module's address entry index"
|
|
::= { smIPv6AddressEntry 2 }
|
|
smIPv6AddressType OBJECT-TYPE
|
|
SYNTAX INTEGER { static(1), dhcp6(2), link-local(3), autconfig(4), configured-static(5) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The address type."
|
|
::= { smIPv6AddressEntry 3 }
|
|
smIPv6Address OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The assigned IPv6 address"
|
|
::= { smIPv6AddressEntry 4 }
|
|
smIPv6AddressPrefixLen OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The prefix length for the given address."
|
|
::= { smIPv6AddressEntry 5 }
|
|
smIPv6AddressDefaultRoute OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The default route used for the given address"
|
|
::= { smIPv6AddressEntry 6 }
|
|
|
|
smIPv6StaticConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmIPv6StaticConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Allows configuration of static IPv6 information for supported
|
|
IO modules.
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in
|
|
Stacking Mode and IP configuration is protected.
|
|
|
|
NOTE: This MIB object is not applicable to modules that
|
|
do not support IPv6."
|
|
::= { switchIPv6Config 3 }
|
|
|
|
smIPv6StaticConfigEntry OBJECT-TYPE
|
|
SYNTAX SmIPv6StaticConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The static IP address assignment information for an
|
|
IO module. Once the assignement has taken place the address
|
|
will show up as a row in the smIPv6AddressTable
|
|
|
|
NOTE: This MIB object is not applicable to modules that are running in
|
|
Stacking Mode and IP configuration is protected.
|
|
|
|
NOTE: This MIB object is not applicable to modules that
|
|
do not support IPv6."
|
|
INDEX { smIPv6StaticIndex}
|
|
::= { smIPv6StaticConfigTable 1 }
|
|
|
|
SmIPv6StaticConfigEntry ::= SEQUENCE {
|
|
smIPv6StaticIndex INTEGER,
|
|
smIPv6StaticAddress InetAddressIPv6,
|
|
smIPv6StaticAddressPrefixLen INTEGER,
|
|
smIPv6StaticAddressDefaultRoute InetAddressIPv6
|
|
}
|
|
|
|
smIPv6StaticIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch module's slot number"
|
|
::= { smIPv6StaticConfigEntry 1 }
|
|
smIPv6StaticAddress OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The assigned IPv6 address.
|
|
|
|
NOTE: If changing with smIPv6StaticAddressPrefixLen and/or
|
|
smIPv6StaticAddressDefaultRoute sending the update as a
|
|
single SET command(in one PDU) will minimize the potential
|
|
downtime of the target switch.
|
|
|
|
NOTE: Sets on this object can take a few seconds. You may
|
|
need to update your SNMP timeout when modifying this setting."
|
|
::= { smIPv6StaticConfigEntry 2 }
|
|
smIPv6StaticAddressPrefixLen OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The prefix length for the given address.
|
|
|
|
NOTE: If changing with smIPv6StaticAddress and/or
|
|
smIPv6StaticAddressDefaultRoute sending the update as a
|
|
single SET command(in one PDU) will minimize the potential
|
|
downtime of the target switch.
|
|
|
|
NOTE: Sets on this object can take a few seconds. You may
|
|
need to update your SNMP timeout when modifying this setting."
|
|
::= { smIPv6StaticConfigEntry 3 }
|
|
smIPv6StaticAddressDefaultRoute OBJECT-TYPE
|
|
SYNTAX InetAddressIPv6
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The default route used for the given address
|
|
|
|
NOTE: If changing with smIPv6StaticAddressPrefixLen and/or
|
|
smIPv6StaticAddress sending the update as a
|
|
single SET command(in one PDU) will minimize the potential
|
|
downtime of the target switch.
|
|
|
|
NOTE: Sets on this object can take a few seconds. You may
|
|
need to update your SNMP timeout when modifying this setting."
|
|
::= { smIPv6StaticConfigEntry 4 }
|
|
|
|
-- ********************************************************************************
|
|
-- Switch module port tables
|
|
-- ********************************************************************************
|
|
switchPortCfg OBJECT IDENTIFIER ::= { switchModuleConfig 2 }
|
|
|
|
switchModOnePortCfg OBJECT IDENTIFIER ::= { switchPortCfg 1 }
|
|
|
|
smOnePortCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmOnePortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 1 port configuration information.
|
|
NOTE: This option is not supported on all I/O modules."
|
|
::= { switchModOnePortCfg 1 }
|
|
|
|
smOnePortCfgEntry OBJECT-TYPE
|
|
SYNTAX SmOnePortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 1 port configuration information table entry"
|
|
INDEX { smOnePortCfgIndex }
|
|
::= { smOnePortCfgTable 1 }
|
|
|
|
SmOnePortCfgEntry ::= SEQUENCE {
|
|
smOnePortCfgIndex INTEGER,
|
|
smOnePortCfgLabel OCTET STRING,
|
|
smOnePortCfgType INTEGER,
|
|
smOnePortCfgLinkSetting INTEGER,
|
|
smOnePortCfgLinkState INTEGER,
|
|
smOnePortCfgSpeedSetting OCTET STRING,
|
|
smOnePortCfgSpeedStatus OCTET STRING,
|
|
smOnePortCfgAvailSpeeds OCTET STRING,
|
|
smOnePortCfgMedia INTEGER,
|
|
smOnePortCfgProtocol INTEGER,
|
|
smOnePortCfgWidth INTEGER,
|
|
smOnePortCfgCableLength INTEGER,
|
|
smOnePortCfgCableType OCTET STRING,
|
|
smOnePortCfgVendorName OCTET STRING,
|
|
smOnePortCfgCompatibility INTEGER,
|
|
smOnePortCfgDataRate INTEGER
|
|
}
|
|
|
|
smOnePortCfgIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 1 port sequence index."
|
|
::= { smOnePortCfgEntry 1 }
|
|
|
|
smOnePortCfgLabel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 1 port label"
|
|
::= { smOnePortCfgEntry 2 }
|
|
|
|
smOnePortCfgType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unused(0),
|
|
externalPort(1),
|
|
externalManagementPort(2),
|
|
externalDualPort(3),
|
|
bladePort(4),
|
|
mmManagementPort(5),
|
|
uplinkPort(6),
|
|
interModulePort(7),
|
|
interModuleManagementPort(8),
|
|
interModuleDualPort(9),
|
|
interModuleExternalBridgePort(10),
|
|
interModuleDualInternalBridgePort(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 1 port type:
|
|
External port: This port is connected to external device and is for data traffic.
|
|
External management port: This port is solely for external management connection.
|
|
This port is not used for data traffic from remote to blades.
|
|
External dual port: This external port is used for both data traffic to blades as well as for management.
|
|
Blade port: This port is connected to the blade.
|
|
Management Module Management port: This port is connected to the Management Module.
|
|
Uplink port: This port is configured for up link functionality.
|
|
Inter-Module port: This port is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type.
|
|
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
|
|
The port type is either by design connected to another I/O Module, by user configured,
|
|
or by AMM setting the port type.
|
|
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
|
|
and management purposes. The port type is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type."
|
|
::= { smOnePortCfgEntry 3 }
|
|
|
|
smOnePortCfgLinkSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link setting for Switch Module 1."
|
|
::= { smOnePortCfgEntry 4 }
|
|
|
|
smOnePortCfgLinkState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1),
|
|
initialized(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link state of Switch Module 1."
|
|
::= { smOnePortCfgEntry 5 }
|
|
|
|
smOnePortCfgSpeedSetting OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the port speed using the data rate and duplex value. For examples:
|
|
100mf: 100 Mbps in Half Duplex;
|
|
10gf: 10 Gbps in Full Duplex;
|
|
auto: The working speed of the physical port can be tuned automatically.
|
|
|
|
NOTE: Only the speeds from smOnePortCfgAvailSpeeds object are applicable to setting
|
|
this mib object."
|
|
::= { smOnePortCfgEntry 6 }
|
|
|
|
smOnePortCfgSpeedStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port speed of Switch Module 1."
|
|
::= { smOnePortCfgEntry 7 }
|
|
|
|
smOnePortCfgAvailSpeeds OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Available speed setting per port for Switch Module 1.
|
|
If there is more than one setting, the speeds are separated by a comma and then a space."
|
|
::= { smOnePortCfgEntry 8 }
|
|
|
|
smOnePortCfgMedia OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
copper(0),
|
|
serdes(1),
|
|
opticalShortHaul(32),
|
|
opticalLongHaul(48),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port media type of Switch Module 1."
|
|
::= { smOnePortCfgEntry 9 }
|
|
|
|
smOnePortCfgProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ethernet(16),
|
|
fibreChannel(32),
|
|
scalability(48),
|
|
infiniband(64),
|
|
pciExpress(80),
|
|
myrinet(112),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port protocol of Switch Module 1."
|
|
::= { smOnePortCfgEntry 10 }
|
|
|
|
smOnePortCfgWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The width of the port in terms of how many combined cables are present for Switch Module 1.
|
|
A value of 0 indicates this field is not applicable to the switch ports.
|
|
This data is also known as the lane count."
|
|
::= { smOnePortCfgEntry 11 }
|
|
|
|
smOnePortCfgCableLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The length (in meters) of the cable supported by this port for Switch Module 1.
|
|
A value of 0 indicates this field is not applicable to the switch ports."
|
|
::= { smOnePortCfgEntry 12 }
|
|
|
|
smOnePortCfgCableType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External cable type for this port, for example, active copper or passive fiber."
|
|
::= { smOnePortCfgEntry 13 }
|
|
|
|
smOnePortCfgVendorName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cable manufacturer."
|
|
::= { smOnePortCfgEntry 14 }
|
|
|
|
smOnePortCfgCompatibility OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
incompatible(0),
|
|
compatible(1),
|
|
compatibleNotRecommended(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compatibility of the external cable that is plugged into the port."
|
|
::= { smOnePortCfgEntry 15 }
|
|
|
|
smOnePortCfgDataRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sdr(0),
|
|
ddr(1),
|
|
qdr(2),
|
|
edr(3),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Data rate supported for this port."
|
|
::= { smOnePortCfgEntry 16 }
|
|
|
|
|
|
switchModTwoPortCfg OBJECT IDENTIFIER ::= { switchPortCfg 2 }
|
|
|
|
smTwoPortCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmTwoPortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 2 port configuration information.
|
|
Note: This option is not supported on all I/O modules."
|
|
::= { switchModTwoPortCfg 1 }
|
|
|
|
smTwoPortCfgEntry OBJECT-TYPE
|
|
SYNTAX SmTwoPortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 2 port configuration information table entry"
|
|
INDEX { smTwoPortCfgIndex }
|
|
::= { smTwoPortCfgTable 1 }
|
|
|
|
SmTwoPortCfgEntry ::= SEQUENCE {
|
|
smTwoPortCfgIndex INTEGER,
|
|
smTwoPortCfgLabel OCTET STRING,
|
|
smTwoPortCfgType INTEGER,
|
|
smTwoPortCfgLinkSetting INTEGER,
|
|
smTwoPortCfgLinkState INTEGER,
|
|
smTwoPortCfgSpeedSetting OCTET STRING,
|
|
smTwoPortCfgSpeedStatus OCTET STRING,
|
|
smTwoPortCfgAvailSpeeds OCTET STRING,
|
|
smTwoPortCfgMedia INTEGER,
|
|
smTwoPortCfgProtocol INTEGER,
|
|
smTwoPortCfgWidth INTEGER,
|
|
smTwoPortCfgCableLength INTEGER,
|
|
smTwoPortCfgCableType OCTET STRING,
|
|
smTwoPortCfgVendorName OCTET STRING,
|
|
smTwoPortCfgCompatibility INTEGER,
|
|
smTwoPortCfgDataRate INTEGER
|
|
}
|
|
|
|
smTwoPortCfgIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 2 port sequence index."
|
|
::= { smTwoPortCfgEntry 1 }
|
|
|
|
smTwoPortCfgLabel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 2 port label"
|
|
::= { smTwoPortCfgEntry 2 }
|
|
|
|
smTwoPortCfgType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unused(0),
|
|
externalPort(1),
|
|
externalManagementPort(2),
|
|
externalDualPort(3),
|
|
bladePort(4),
|
|
mmManagementPort(5),
|
|
uplinkPort(6),
|
|
interModulePort(7),
|
|
interModuleManagementPort(8),
|
|
interModuleDualPort(9),
|
|
interModuleExternalBridgePort(10),
|
|
interModuleDualInternalBridgePort(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 2 port type:
|
|
External port: This port is connected to external device and is for data traffic.
|
|
External management port: This port is solely for external management connection.
|
|
This port is not used for data traffic from remote to blades.
|
|
External dual port: This external port is used for both data traffic to blades as well as for management.
|
|
Blade port: This port is connected to the blade.
|
|
Management Module Management port: This port is connected to the Management Module.
|
|
Uplink port: This port is configured for up link functionality.
|
|
Inter-Module port: This port is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type.
|
|
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
|
|
The port type is either by design connected to another I/O Module, by user configured,
|
|
or by AMM setting the port type.
|
|
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
|
|
and management purposes. The port type is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type."
|
|
::= { smTwoPortCfgEntry 3 }
|
|
|
|
smTwoPortCfgLinkSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link setting for Switch Module 2."
|
|
::= { smTwoPortCfgEntry 4 }
|
|
|
|
smTwoPortCfgLinkState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1),
|
|
initialized(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link state of Switch Module 2."
|
|
::= { smTwoPortCfgEntry 5 }
|
|
|
|
smTwoPortCfgSpeedSetting OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the port speed using the data rate and duplex value. For examples:
|
|
100mf: 100Mbps in Half Duplex;
|
|
10gf: 10 Gbps in Full Duplex;
|
|
auto: The working speed of the physical port can be tuned automatically.
|
|
|
|
NOTE: Only the speeds from smTwoPortCfgAvailSpeeds are applicable to setting
|
|
this mib object."
|
|
::= { smTwoPortCfgEntry 6 }
|
|
|
|
smTwoPortCfgSpeedStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port speed of Switch Module 2."
|
|
::= { smTwoPortCfgEntry 7 }
|
|
|
|
smTwoPortCfgAvailSpeeds OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Available speed setting per port for Switch Module 2.
|
|
If there is more than one setting, the speeds are separated by a comma and then a space."
|
|
::= { smTwoPortCfgEntry 8 }
|
|
|
|
smTwoPortCfgMedia OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
copper(0),
|
|
serdes(1),
|
|
opticalShortHaul(32),
|
|
opticalLongHaul(48),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port media type of Switch Module 2."
|
|
::= { smTwoPortCfgEntry 9 }
|
|
|
|
smTwoPortCfgProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ethernet(16),
|
|
fibreChannel(32),
|
|
scalability(48),
|
|
infiniband(64),
|
|
pciExpress(80),
|
|
myrinet(112),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port protocol of Switch Module 2."
|
|
::= { smTwoPortCfgEntry 10 }
|
|
|
|
smTwoPortCfgWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The width of the port in terms of how many combined cables are present for Switch Module 2.
|
|
A value of 0 indicates this field is not applicable to the switch ports.
|
|
This data is also known as the lane count."
|
|
::= { smTwoPortCfgEntry 11 }
|
|
|
|
smTwoPortCfgCableLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The length (in meters) of the cable supported by this port for Switch Module 2.
|
|
A value of 0 indicates this field is not applicable to the switch ports."
|
|
::= { smTwoPortCfgEntry 12 }
|
|
|
|
smTwoPortCfgCableType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External cable type for this port, for example, active copper or passive fiber."
|
|
::= { smTwoPortCfgEntry 13 }
|
|
|
|
smTwoPortCfgVendorName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cable manufacturer."
|
|
::= { smTwoPortCfgEntry 14 }
|
|
|
|
smTwoPortCfgCompatibility OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
incompatible(0),
|
|
compatible(1),
|
|
compatibleNotRecommended(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compatibility of the external cable that is plugged into the port."
|
|
::= { smTwoPortCfgEntry 15 }
|
|
|
|
smTwoPortCfgDataRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sdr(0),
|
|
ddr(1),
|
|
qdr(2),
|
|
edr(3),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Data rate supported for this port."
|
|
::= { smTwoPortCfgEntry 16 }
|
|
|
|
switchModThreePortCfg OBJECT IDENTIFIER ::= { switchPortCfg 3 }
|
|
|
|
smThreePortCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmThreePortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 3 port configuration information.
|
|
Note: This option is not supported on all I/O modules."
|
|
::= { switchModThreePortCfg 1 }
|
|
|
|
smThreePortCfgEntry OBJECT-TYPE
|
|
SYNTAX SmThreePortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 3 port configuration information table entry"
|
|
INDEX { smThreePortCfgIndex }
|
|
::= { smThreePortCfgTable 1 }
|
|
|
|
SmThreePortCfgEntry ::= SEQUENCE {
|
|
smThreePortCfgIndex INTEGER,
|
|
smThreePortCfgLabel OCTET STRING,
|
|
smThreePortCfgType INTEGER,
|
|
smThreePortCfgLinkSetting INTEGER,
|
|
smThreePortCfgLinkState INTEGER,
|
|
smThreePortCfgSpeedSetting OCTET STRING,
|
|
smThreePortCfgSpeedStatus OCTET STRING,
|
|
smThreePortCfgAvailSpeeds OCTET STRING,
|
|
smThreePortCfgMedia INTEGER,
|
|
smThreePortCfgProtocol INTEGER,
|
|
smThreePortCfgWidth INTEGER,
|
|
smThreePortCfgCableLength INTEGER,
|
|
smThreePortCfgCableType OCTET STRING,
|
|
smThreePortCfgVendorName OCTET STRING,
|
|
smThreePortCfgCompatibility INTEGER,
|
|
smThreePortCfgDataRate INTEGER
|
|
}
|
|
|
|
smThreePortCfgIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 3 port sequence index."
|
|
::= { smThreePortCfgEntry 1 }
|
|
|
|
smThreePortCfgLabel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 3 port label"
|
|
::= { smThreePortCfgEntry 2 }
|
|
|
|
smThreePortCfgType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unused(0),
|
|
externalPort(1),
|
|
externalManagementPort(2),
|
|
externalDualPort(3),
|
|
bladePort(4),
|
|
mmManagementPort(5),
|
|
uplinkPort(6),
|
|
interModulePort(7),
|
|
interModuleManagementPort(8),
|
|
interModuleDualPort(9),
|
|
interModuleExternalBridgePort(10),
|
|
interModuleDualInternalBridgePort(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 3 port type:
|
|
External port: This port is connected to external device and is for data traffic.
|
|
External management port: This port is solely for external management connection.
|
|
This port is not used for data traffic from remote to blades.
|
|
External dual port: This external port is used for both data traffic to blades as well as for management.
|
|
Blade port: This port is connected to the blade.
|
|
Management Module Management port: This port is connected to the Management Module.
|
|
Uplink port: This port is configured for up link functionality.
|
|
Inter-Module port: This port is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type.
|
|
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
|
|
The port type is either by design connected to another I/O Module, by user configured,
|
|
or by AMM setting the port type.
|
|
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
|
|
and management purposes. The port type is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type."
|
|
::= { smThreePortCfgEntry 3 }
|
|
|
|
smThreePortCfgLinkSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link setting for Switch Module 3."
|
|
::= { smThreePortCfgEntry 4 }
|
|
|
|
smThreePortCfgLinkState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1),
|
|
initialized(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link state of Switch Module 3."
|
|
::= { smThreePortCfgEntry 5 }
|
|
|
|
smThreePortCfgSpeedSetting OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the port speed using the data rate and duplex value. For examples:
|
|
100mf: 100Mbps in Half Duplex;
|
|
10gf: 10 Gbps in Full Duplex;
|
|
auto: The working speed of the physical port can be tuned automatically.
|
|
|
|
NOTE: Only the speeds from smThreePortCfgAvailSpeeds are applicable to setting
|
|
this mib object."
|
|
::= { smThreePortCfgEntry 6 }
|
|
|
|
smThreePortCfgSpeedStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port speed of Switch Module 3."
|
|
::= { smThreePortCfgEntry 7 }
|
|
|
|
smThreePortCfgAvailSpeeds OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Available speed setting per port for Switch Module 3.
|
|
If there is more than one setting, the speeds are separated by a comma and then a space."
|
|
::= { smThreePortCfgEntry 8 }
|
|
|
|
smThreePortCfgMedia OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
copper(0),
|
|
serdes(1),
|
|
opticalShortHaul(32),
|
|
opticalLongHaul(48),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port media type of Switch Module 3."
|
|
::= { smThreePortCfgEntry 9 }
|
|
|
|
smThreePortCfgProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ethernet(16),
|
|
fibreChannel(32),
|
|
scalability(48),
|
|
infiniband(64),
|
|
pciExpress(80),
|
|
myrinet(112),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port protocol of Switch Module 3."
|
|
::= { smThreePortCfgEntry 10 }
|
|
|
|
smThreePortCfgWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The width of the port in terms of how many combined cables are present for Switch Module 3.
|
|
A value of 0 indicates this field is not applicable to the switch ports.
|
|
This data is also known as the lane count."
|
|
::= { smThreePortCfgEntry 11 }
|
|
|
|
smThreePortCfgCableLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The length (in meters) of the cable supported by this port for Switch Module 3.
|
|
A value of 0 indicates this field is not applicable to the switch ports."
|
|
::= { smThreePortCfgEntry 12 }
|
|
|
|
smThreePortCfgCableType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External cable type for this port, for example, active copper or passive fiber."
|
|
::= { smThreePortCfgEntry 13 }
|
|
|
|
smThreePortCfgVendorName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cable manufacturer."
|
|
::= { smThreePortCfgEntry 14 }
|
|
|
|
smThreePortCfgCompatibility OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
incompatible(0),
|
|
compatible(1),
|
|
compatibleNotRecommended(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compatibility of the external cable that is plugged into the port."
|
|
::= { smThreePortCfgEntry 15 }
|
|
|
|
smThreePortCfgDataRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sdr(0),
|
|
ddr(1),
|
|
qdr(2),
|
|
edr(3),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Data rate supported for this port."
|
|
::= { smThreePortCfgEntry 16 }
|
|
|
|
|
|
switchModFourPortCfg OBJECT IDENTIFIER ::= { switchPortCfg 4 }
|
|
|
|
smFourPortCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmFourPortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 4 port configuration information.
|
|
Note: This option is not supported on all I/O modules."
|
|
::= { switchModFourPortCfg 1 }
|
|
|
|
smFourPortCfgEntry OBJECT-TYPE
|
|
SYNTAX SmFourPortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 4 port configuration information table entry"
|
|
INDEX { smFourPortCfgIndex }
|
|
::= { smFourPortCfgTable 1 }
|
|
|
|
SmFourPortCfgEntry ::= SEQUENCE {
|
|
smFourPortCfgIndex INTEGER,
|
|
smFourPortCfgLabel OCTET STRING,
|
|
smFourPortCfgType INTEGER,
|
|
smFourPortCfgLinkSetting INTEGER,
|
|
smFourPortCfgLinkState INTEGER,
|
|
smFourPortCfgSpeedSetting OCTET STRING,
|
|
smFourPortCfgSpeedStatus OCTET STRING,
|
|
smFourPortCfgAvailSpeeds OCTET STRING,
|
|
smFourPortCfgMedia INTEGER,
|
|
smFourPortCfgProtocol INTEGER,
|
|
smFourPortCfgWidth INTEGER,
|
|
smFourPortCfgCableLength INTEGER,
|
|
smFourPortCfgCableType OCTET STRING,
|
|
smFourPortCfgVendorName OCTET STRING,
|
|
smFourPortCfgCompatibility INTEGER,
|
|
smFourPortCfgDataRate INTEGER
|
|
}
|
|
|
|
smFourPortCfgIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 4 port sequence index."
|
|
::= { smFourPortCfgEntry 1 }
|
|
|
|
smFourPortCfgLabel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 4 port label"
|
|
::= { smFourPortCfgEntry 2 }
|
|
|
|
smFourPortCfgType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unused(0),
|
|
externalPort(1),
|
|
externalManagementPort(2),
|
|
externalDualPort(3),
|
|
bladePort(4),
|
|
mmManagementPort(5),
|
|
uplinkPort(6),
|
|
interModulePort(7),
|
|
interModuleManagementPort(8),
|
|
interModuleDualPort(9),
|
|
interModuleExternalBridgePort(10),
|
|
interModuleDualInternalBridgePort(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 4 port type:
|
|
External port: This port is connected to external device and is for data traffic.
|
|
External management port: This port is solely for external management connection.
|
|
This port is not used for data traffic from remote to blades.
|
|
External dual port: This external port is used for both data traffic to blades as well as for management.
|
|
Blade port: This port is connected to the blade.
|
|
Management Module Management port: This port is connected to the Management Module.
|
|
Uplink port: This port is configured for up link functionality.
|
|
Inter-Module port: This port is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type.
|
|
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
|
|
The port type is either by design connected to another I/O Module, by user configured,
|
|
or by AMM setting the port type.
|
|
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
|
|
and management purposes. The port type is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type."
|
|
::= { smFourPortCfgEntry 3 }
|
|
|
|
smFourPortCfgLinkSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link setting for Switch Module 4."
|
|
::= { smFourPortCfgEntry 4 }
|
|
|
|
smFourPortCfgLinkState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1),
|
|
initialized(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link state of Switch Module 4."
|
|
::= { smFourPortCfgEntry 5 }
|
|
|
|
smFourPortCfgSpeedSetting OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the port speed using the data rate and duplex value. For examples:
|
|
100mf: 100Mbps in Half Duplex;
|
|
10gf: 10 Gbps in Full Duplex;
|
|
auto: The working speed of the physical port can be tuned automatically.
|
|
|
|
NOTE: Only the speeds from smFourPortCfgAvailSpeeds are applicable to setting
|
|
this mib object."
|
|
::= { smFourPortCfgEntry 6 }
|
|
|
|
smFourPortCfgSpeedStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port speed of Switch Module 4."
|
|
::= { smFourPortCfgEntry 7 }
|
|
|
|
|
|
smFourPortCfgAvailSpeeds OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Available speed setting per port for Switch Module 4.
|
|
If there is more than one setting, the speeds are separated by a comma and then a space."
|
|
::= { smFourPortCfgEntry 8 }
|
|
|
|
smFourPortCfgMedia OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
copper(0),
|
|
serdes(1),
|
|
opticalShortHaul(32),
|
|
opticalLongHaul(48),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port media type of Switch Module 4."
|
|
::= { smFourPortCfgEntry 9 }
|
|
|
|
smFourPortCfgProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ethernet(16),
|
|
fibreChannel(32),
|
|
scalability(48),
|
|
infiniband(64),
|
|
pciExpress(80),
|
|
myrinet(112),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port protocol of Switch Module 4."
|
|
::= { smFourPortCfgEntry 10 }
|
|
|
|
smFourPortCfgWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The width of the port in terms of how many combined cables are present for Switch Module 4.
|
|
A value of 0 indicates this field is not applicable to the switch ports.
|
|
This data is also known as the lane count."
|
|
::= { smFourPortCfgEntry 11 }
|
|
|
|
smFourPortCfgCableLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The length (in meters) of the cable supported by this port for Switch Module 4.
|
|
A value of 0 indicates this field is not applicable to the switch ports."
|
|
::= { smFourPortCfgEntry 12 }
|
|
|
|
smFourPortCfgCableType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External cable type for this port, for example, active copper or passive fiber."
|
|
::= { smFourPortCfgEntry 13 }
|
|
|
|
smFourPortCfgVendorName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cable manufacturer."
|
|
::= { smFourPortCfgEntry 14 }
|
|
|
|
smFourPortCfgCompatibility OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
incompatible(0),
|
|
compatible(1),
|
|
compatibleNotRecommended(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compatibility of the external cable that is plugged into the port."
|
|
::= { smFourPortCfgEntry 15 }
|
|
|
|
smFourPortCfgDataRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sdr(0),
|
|
ddr(1),
|
|
qdr(2),
|
|
edr(3),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Data rate supported for this port."
|
|
::= { smFourPortCfgEntry 16 }
|
|
|
|
|
|
switchModFivePortCfg OBJECT IDENTIFIER ::= { switchPortCfg 5 }
|
|
|
|
smFivePortCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmFivePortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 5 port configuration information.
|
|
Note: This option is not supported on all I/O modules."
|
|
::= { switchModFivePortCfg 1 }
|
|
|
|
smFivePortCfgEntry OBJECT-TYPE
|
|
SYNTAX SmFivePortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 5 port configuration information table entry"
|
|
INDEX { smFivePortCfgIndex }
|
|
::= { smFivePortCfgTable 1 }
|
|
|
|
SmFivePortCfgEntry ::= SEQUENCE {
|
|
smFivePortCfgIndex INTEGER,
|
|
smFivePortCfgLabel OCTET STRING,
|
|
smFivePortCfgType INTEGER,
|
|
smFivePortCfgLinkSetting INTEGER,
|
|
smFivePortCfgLinkState INTEGER,
|
|
smFivePortCfgSpeedSetting OCTET STRING,
|
|
smFivePortCfgSpeedStatus OCTET STRING,
|
|
smFivePortCfgAvailSpeeds OCTET STRING,
|
|
smFivePortCfgMedia INTEGER,
|
|
smFivePortCfgProtocol INTEGER,
|
|
smFivePortCfgWidth INTEGER,
|
|
smFivePortCfgCableLength INTEGER,
|
|
smFivePortCfgCableType OCTET STRING,
|
|
smFivePortCfgVendorName OCTET STRING,
|
|
smFivePortCfgCompatibility INTEGER,
|
|
smFivePortCfgDataRate INTEGER
|
|
}
|
|
|
|
smFivePortCfgIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 5 port sequence index."
|
|
::= { smFivePortCfgEntry 1 }
|
|
|
|
smFivePortCfgLabel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 5 port label"
|
|
::= { smFivePortCfgEntry 2 }
|
|
|
|
smFivePortCfgType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unused(0),
|
|
externalPort(1),
|
|
externalManagementPort(2),
|
|
externalDualPort(3),
|
|
bladePort(4),
|
|
mmManagementPort(5),
|
|
uplinkPort(6),
|
|
interModulePort(7),
|
|
interModuleManagementPort(8),
|
|
interModuleDualPort(9),
|
|
interModuleExternalBridgePort(10),
|
|
interModuleDualInternalBridgePort(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 5 port type:
|
|
External port: This port is connected to external device and is for data traffic.
|
|
External management port: This port is solely for external management connection.
|
|
This port is not used for data traffic from remote to blades.
|
|
External dual port: This external port is used for both data traffic to blades as well as for management.
|
|
Blade port: This port is connected to the blade.
|
|
Management Module Management port: This port is connected to the Management Module.
|
|
Uplink port: This port is configured for up link functionality.
|
|
Inter-Module port: This port is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type.
|
|
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
|
|
The port type is either by design connected to another I/O Module, by user configured,
|
|
or by AMM setting the port type.
|
|
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
|
|
and management purposes. The port type is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type."
|
|
::= { smFivePortCfgEntry 3 }
|
|
|
|
smFivePortCfgLinkSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link setting for Switch Module 5."
|
|
::= { smFivePortCfgEntry 4 }
|
|
|
|
smFivePortCfgLinkState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1),
|
|
initialized(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link state of Switch Module 5."
|
|
::= { smFivePortCfgEntry 5 }
|
|
|
|
smFivePortCfgSpeedSetting OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the port speed using the data rate and duplex value. For examples:
|
|
100mf: 100Mbps in Half Duplex;
|
|
10gf: 10 Gbps in Full Duplex;
|
|
auto: The working speed of the physical port can be tuned automatically.
|
|
|
|
NOTE: Only the speeds from smFivePortCfgAvailSpeeds are applicable to setting
|
|
this mib object."
|
|
::= { smFivePortCfgEntry 6 }
|
|
|
|
smFivePortCfgSpeedStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port speed of Switch Module 5."
|
|
::= { smFivePortCfgEntry 7 }
|
|
|
|
smFivePortCfgAvailSpeeds OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Available speed setting per port for Switch Module 5.
|
|
If there is more than one setting, the speeds are separated by a comma and then a space."
|
|
::= { smFivePortCfgEntry 8 }
|
|
|
|
smFivePortCfgMedia OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
copper(0),
|
|
serdes(1),
|
|
opticalShortHaul(32),
|
|
opticalLongHaul(48),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port media type of Switch Module 5."
|
|
::= { smFivePortCfgEntry 9 }
|
|
|
|
smFivePortCfgProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ethernet(16),
|
|
fibreChannel(32),
|
|
scalability(48),
|
|
infiniband(64),
|
|
pciExpress(80),
|
|
myrinet(112),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port protocol of Switch Module 5."
|
|
::= { smFivePortCfgEntry 10 }
|
|
|
|
smFivePortCfgWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The width of the port in terms of how many combined cables are present for Switch Module 5.
|
|
A value of 0 indicates this field is not applicable to the switch ports.
|
|
This data is also known as the lane count."
|
|
::= { smFivePortCfgEntry 11 }
|
|
|
|
smFivePortCfgCableLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The length (in meters) of the cable supported by this port for Switch Module 5.
|
|
A value of 0 indicates this field is not applicable to the switch ports."
|
|
::= { smFivePortCfgEntry 12 }
|
|
|
|
smFivePortCfgCableType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External cable type for this port, for example, active copper or passive fiber."
|
|
::= { smFivePortCfgEntry 13 }
|
|
|
|
smFivePortCfgVendorName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cable manufacturer."
|
|
::= { smFivePortCfgEntry 14 }
|
|
|
|
smFivePortCfgCompatibility OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
incompatible(0),
|
|
compatible(1),
|
|
compatibleNotRecommended(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compatibility of the external cable that is plugged into the port."
|
|
::= { smFivePortCfgEntry 15 }
|
|
|
|
smFivePortCfgDataRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sdr(0),
|
|
ddr(1),
|
|
qdr(2),
|
|
edr(3),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Data rate supported for this port."
|
|
::= { smFivePortCfgEntry 16 }
|
|
|
|
|
|
switchModSixPortCfg OBJECT IDENTIFIER ::= { switchPortCfg 6 }
|
|
|
|
smSixPortCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmSixPortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 6 port configuration information.
|
|
Note: This option is not supported on all I/O modules."
|
|
::= { switchModSixPortCfg 1 }
|
|
|
|
smSixPortCfgEntry OBJECT-TYPE
|
|
SYNTAX SmSixPortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 6 port configuration information table entry"
|
|
INDEX { smSixPortCfgIndex }
|
|
::= { smSixPortCfgTable 1 }
|
|
|
|
SmSixPortCfgEntry ::= SEQUENCE {
|
|
smSixPortCfgIndex INTEGER,
|
|
smSixPortCfgLabel OCTET STRING,
|
|
smSixPortCfgType INTEGER,
|
|
smSixPortCfgLinkSetting INTEGER,
|
|
smSixPortCfgLinkState INTEGER,
|
|
smSixPortCfgSpeedSetting OCTET STRING,
|
|
smSixPortCfgSpeedStatus OCTET STRING,
|
|
smSixPortCfgAvailSpeeds OCTET STRING,
|
|
smSixPortCfgMedia INTEGER,
|
|
smSixPortCfgProtocol INTEGER,
|
|
smSixPortCfgWidth INTEGER,
|
|
smSixPortCfgCableLength INTEGER,
|
|
smSixPortCfgCableType OCTET STRING,
|
|
smSixPortCfgVendorName OCTET STRING,
|
|
smSixPortCfgCompatibility INTEGER,
|
|
smSixPortCfgDataRate INTEGER
|
|
}
|
|
|
|
smSixPortCfgIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 6 port sequence index."
|
|
::= { smSixPortCfgEntry 1 }
|
|
|
|
smSixPortCfgLabel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 6 port label"
|
|
::= { smSixPortCfgEntry 2 }
|
|
|
|
smSixPortCfgType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unused(0),
|
|
externalPort(1),
|
|
externalManagementPort(2),
|
|
externalDualPort(3),
|
|
bladePort(4),
|
|
mmManagementPort(5),
|
|
uplinkPort(6),
|
|
interModulePort(7),
|
|
interModuleManagementPort(8),
|
|
interModuleDualPort(9),
|
|
interModuleExternalBridgePort(10),
|
|
interModuleDualInternalBridgePort(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 6 port type:
|
|
External port: This port is connected to external device and is for data traffic.
|
|
External management port: This port is solely for external management connection.
|
|
This port is not used for data traffic from remote to blades.
|
|
External dual port: This external port is used for both data traffic to blades as well as for management.
|
|
Blade port: This port is connected to the blade.
|
|
Management Module Management port: This port is connected to the Management Module.
|
|
Uplink port: This port is configured for up link functionality.
|
|
Inter-Module port: This port is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type.
|
|
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
|
|
The port type is either by design connected to another I/O Module, by user configured,
|
|
or by AMM setting the port type.
|
|
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
|
|
and management purposes. The port type is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type."
|
|
::= { smSixPortCfgEntry 3 }
|
|
|
|
smSixPortCfgLinkSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link setting for Switch Module 6."
|
|
::= { smSixPortCfgEntry 4 }
|
|
|
|
smSixPortCfgLinkState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1),
|
|
initialized(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link state of Switch Module 6."
|
|
::= { smSixPortCfgEntry 5 }
|
|
|
|
smSixPortCfgSpeedSetting OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the port speed using the data rate and duplex value. For examples:
|
|
100mf: 100Mbps in Half Duplex;
|
|
10gf: 10 Gbps in Full Duplex;
|
|
auto: The working speed of the physical port can be tuned automatically.
|
|
|
|
NOTE: Only the speeds from smSixPortCfgAvailSpeeds are applicable to setting
|
|
this mib object."
|
|
::= { smSixPortCfgEntry 6 }
|
|
|
|
smSixPortCfgSpeedStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port speed of Switch Module 6."
|
|
::= { smSixPortCfgEntry 7 }
|
|
|
|
smSixPortCfgAvailSpeeds OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Available speed setting per port for Switch Module 6.
|
|
If there is more than one setting, the speeds are separated by a comma and then a space."
|
|
::= { smSixPortCfgEntry 8 }
|
|
|
|
smSixPortCfgMedia OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
copper(0),
|
|
serdes(1),
|
|
opticalShortHaul(32),
|
|
opticalLongHaul(48),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port media type of Switch Module 6."
|
|
::= { smSixPortCfgEntry 9 }
|
|
|
|
smSixPortCfgProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ethernet(16),
|
|
fibreChannel(32),
|
|
scalability(48),
|
|
infiniband(64),
|
|
pciExpress(80),
|
|
myrinet(112),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port protocol of Switch Module 6."
|
|
::= { smSixPortCfgEntry 10 }
|
|
|
|
smSixPortCfgWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The width of the port in terms of how many combined cables are present for Switch Module 6.
|
|
A value of 0 indicates this field is not applicable to the switch ports.
|
|
This data is also known as the lane count."
|
|
::= { smSixPortCfgEntry 11 }
|
|
|
|
smSixPortCfgCableLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The length (in meters) of the cable supported by this port for Switch Module 6.
|
|
A value of 0 indicates this field is not applicable to the switch ports."
|
|
::= { smSixPortCfgEntry 12 }
|
|
|
|
smSixPortCfgCableType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External cable type for this port, for example, active copper or passive fiber."
|
|
::= { smSixPortCfgEntry 13 }
|
|
|
|
smSixPortCfgVendorName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cable manufacturer."
|
|
::= { smSixPortCfgEntry 14 }
|
|
|
|
smSixPortCfgCompatibility OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
incompatible(0),
|
|
compatible(1),
|
|
compatibleNotRecommended(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compatibility of the external cable that is plugged into the port."
|
|
::= { smSixPortCfgEntry 15 }
|
|
|
|
smSixPortCfgDataRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sdr(0),
|
|
ddr(1),
|
|
qdr(2),
|
|
edr(3),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Data rate supported for this port."
|
|
::= { smSixPortCfgEntry 16 }
|
|
|
|
|
|
switchModSevenPortCfg OBJECT IDENTIFIER ::= { switchPortCfg 7 }
|
|
|
|
smSevenPortCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmSevenPortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 7 port configuration information.
|
|
Note: This option is not supported on all I/O modules."
|
|
::= { switchModSevenPortCfg 1 }
|
|
|
|
smSevenPortCfgEntry OBJECT-TYPE
|
|
SYNTAX SmSevenPortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 7 port configuration information table entry"
|
|
INDEX { smSevenPortCfgIndex }
|
|
::= { smSevenPortCfgTable 1 }
|
|
|
|
SmSevenPortCfgEntry ::= SEQUENCE {
|
|
smSevenPortCfgIndex INTEGER,
|
|
smSevenPortCfgLabel OCTET STRING,
|
|
smSevenPortCfgType INTEGER,
|
|
smSevenPortCfgLinkSetting INTEGER,
|
|
smSevenPortCfgLinkState INTEGER,
|
|
smSevenPortCfgSpeedSetting OCTET STRING,
|
|
smSevenPortCfgSpeedStatus OCTET STRING,
|
|
smSevenPortCfgAvailSpeeds OCTET STRING,
|
|
smSevenPortCfgMedia INTEGER,
|
|
smSevenPortCfgProtocol INTEGER,
|
|
smSevenPortCfgWidth INTEGER,
|
|
smSevenPortCfgCableLength INTEGER,
|
|
smSevenPortCfgCableType OCTET STRING,
|
|
smSevenPortCfgVendorName OCTET STRING,
|
|
smSevenPortCfgCompatibility INTEGER,
|
|
smSevenPortCfgDataRate INTEGER
|
|
}
|
|
|
|
smSevenPortCfgIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 7 port sequence index."
|
|
::= { smSevenPortCfgEntry 1 }
|
|
|
|
smSevenPortCfgLabel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 7 port label"
|
|
::= { smSevenPortCfgEntry 2 }
|
|
|
|
smSevenPortCfgType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unused(0),
|
|
externalPort(1),
|
|
externalManagementPort(2),
|
|
externalDualPort(3),
|
|
bladePort(4),
|
|
mmManagementPort(5),
|
|
uplinkPort(6),
|
|
interModulePort(7),
|
|
interModuleManagementPort(8),
|
|
interModuleDualPort(9),
|
|
interModuleExternalBridgePort(10),
|
|
interModuleDualInternalBridgePort(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 7 port type:
|
|
External port: This port is connected to external device and is for data traffic.
|
|
External management port: This port is solely for external management connection.
|
|
This port is not used for data traffic from remote to blades.
|
|
External dual port: This external port is used for both data traffic to blades as well as for management.
|
|
Blade port: This port is connected to the blade.
|
|
Management Module Management port: This port is connected to the Management Module.
|
|
Uplink port: This port is configured for up link functionality.
|
|
Inter-Module port: This port is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type.
|
|
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
|
|
The port type is either by design connected to another I/O Module, by user configured,
|
|
or by AMM setting the port type.
|
|
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
|
|
and management purposes. The port type is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type."
|
|
::= { smSevenPortCfgEntry 3 }
|
|
|
|
smSevenPortCfgLinkSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link setting for Switch Module 7."
|
|
::= { smSevenPortCfgEntry 4 }
|
|
|
|
smSevenPortCfgLinkState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1),
|
|
initialized(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link state of Switch Module 7."
|
|
::= { smSevenPortCfgEntry 5 }
|
|
|
|
smSevenPortCfgSpeedSetting OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the port speed using the data rate and duplex value. For examples:
|
|
100mf: 100Mbps in Half Duplex;
|
|
10gf: 10 Gbps in Full Duplex;
|
|
auto: The working speed of the physical port can be tuned automatically.
|
|
|
|
NOTE: Only the speeds from smSevenPortCfgAvailSpeeds are applicable to setting
|
|
this mib object."
|
|
::= { smSevenPortCfgEntry 6 }
|
|
|
|
smSevenPortCfgSpeedStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port speed of Switch Module 7."
|
|
::= { smSevenPortCfgEntry 7 }
|
|
|
|
smSevenPortCfgAvailSpeeds OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Available speed setting per port for Switch Module 7.
|
|
If there is more than one setting, the speeds are separated by a comma and then a space."
|
|
::= { smSevenPortCfgEntry 8 }
|
|
|
|
smSevenPortCfgMedia OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
copper(0),
|
|
serdes(1),
|
|
opticalShortHaul(32),
|
|
opticalLongHaul(48),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port media type of Switch Module 7."
|
|
::= { smSevenPortCfgEntry 9 }
|
|
|
|
smSevenPortCfgProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ethernet(16),
|
|
fibreChannel(32),
|
|
scalability(48),
|
|
infiniband(64),
|
|
pciExpress(80),
|
|
myrinet(112),
|
|
notApplicable(255)
|
|
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port protocol of Switch Module 7."
|
|
::= { smSevenPortCfgEntry 10 }
|
|
|
|
smSevenPortCfgWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The width of the port in terms of how many combined cables are present for Switch Module 7.
|
|
A value of 0 indicates this field is not applicable to the switch ports.
|
|
This data is also known as the lane count."
|
|
::= { smSevenPortCfgEntry 11 }
|
|
|
|
smSevenPortCfgCableLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The length (in meters) of the cable supported by this port for Switch Module 7.
|
|
A value of 0 indicates this field is not applicable to the switch ports."
|
|
::= { smSevenPortCfgEntry 12 }
|
|
|
|
smSevenPortCfgCableType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External cable type for this port, for example, active copper or passive fiber."
|
|
::= { smSevenPortCfgEntry 13 }
|
|
|
|
smSevenPortCfgVendorName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cable manufacturer."
|
|
::= { smSevenPortCfgEntry 14 }
|
|
|
|
smSevenPortCfgCompatibility OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
incompatible(0),
|
|
compatible(1),
|
|
compatibleNotRecommended(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compatibility of the external cable that is plugged into the port."
|
|
::= { smSevenPortCfgEntry 15 }
|
|
|
|
smSevenPortCfgDataRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sdr(0),
|
|
ddr(1),
|
|
qdr(2),
|
|
edr(3),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Data rate supported for this port."
|
|
::= { smSevenPortCfgEntry 16 }
|
|
|
|
|
|
switchModEightPortCfg OBJECT IDENTIFIER ::= { switchPortCfg 8 }
|
|
|
|
smEightPortCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmEightPortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 8 port configuration information.
|
|
Note: This option is not supported on all I/O modules."
|
|
::= { switchModEightPortCfg 1 }
|
|
|
|
smEightPortCfgEntry OBJECT-TYPE
|
|
SYNTAX SmEightPortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 8 port configuration information table entry"
|
|
INDEX { smEightPortCfgIndex }
|
|
::= { smEightPortCfgTable 1 }
|
|
|
|
SmEightPortCfgEntry ::= SEQUENCE {
|
|
smEightPortCfgIndex INTEGER,
|
|
smEightPortCfgLabel OCTET STRING,
|
|
smEightPortCfgType INTEGER,
|
|
smEightPortCfgLinkSetting INTEGER,
|
|
smEightPortCfgLinkState INTEGER,
|
|
smEightPortCfgSpeedSetting OCTET STRING,
|
|
smEightPortCfgSpeedStatus OCTET STRING,
|
|
smEightPortCfgAvailSpeeds OCTET STRING,
|
|
smEightPortCfgMedia INTEGER,
|
|
smEightPortCfgProtocol INTEGER,
|
|
smEightPortCfgWidth INTEGER,
|
|
smEightPortCfgCableLength INTEGER,
|
|
smEightPortCfgCableType OCTET STRING,
|
|
smEightPortCfgVendorName OCTET STRING,
|
|
smEightPortCfgCompatibility INTEGER,
|
|
smEightPortCfgDataRate INTEGER
|
|
}
|
|
|
|
smEightPortCfgIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 8 port sequence index."
|
|
::= { smEightPortCfgEntry 1 }
|
|
|
|
smEightPortCfgLabel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 8 port label"
|
|
::= { smEightPortCfgEntry 2 }
|
|
|
|
smEightPortCfgType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unused(0),
|
|
externalPort(1),
|
|
externalManagementPort(2),
|
|
externalDualPort(3),
|
|
bladePort(4),
|
|
mmManagementPort(5),
|
|
uplinkPort(6),
|
|
interModulePort(7),
|
|
interModuleManagementPort(8),
|
|
interModuleDualPort(9),
|
|
interModuleExternalBridgePort(10),
|
|
interModuleDualInternalBridgePort(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 8 port type:
|
|
External port: This port is connected to external device and is for data traffic.
|
|
External management port: This port is solely for external management connection.
|
|
This port is not used for data traffic from remote to blades.
|
|
External dual port: This external port is used for both data traffic to blades as well as for management.
|
|
Blade port: This port is connected to the blade.
|
|
Management Module Management port: This port is connected to the Management Module.
|
|
Uplink port: This port is configured for up link functionality.
|
|
Inter-Module port: This port is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type.
|
|
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
|
|
The port type is either by design connected to another I/O Module, by user configured,
|
|
or by AMM setting the port type.
|
|
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
|
|
and management purposes. The port type is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type."
|
|
::= { smEightPortCfgEntry 3 }
|
|
|
|
smEightPortCfgLinkSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link setting for Switch Module 8."
|
|
::= { smEightPortCfgEntry 4 }
|
|
|
|
smEightPortCfgLinkState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1),
|
|
initialized(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link state of Switch Module 8."
|
|
::= { smEightPortCfgEntry 5 }
|
|
|
|
smEightPortCfgSpeedSetting OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the port speed using the data rate and duplex value. For examples:
|
|
100mf: 100Mbps in Half Duplex;
|
|
10gf: 10 Gbps in Full Duplex;
|
|
auto: The working speed of the physical port can be tuned automatically.
|
|
|
|
NOTE: Only the speeds from smEightPortCfgAvailSpeeds are applicable to setting
|
|
this mib object."
|
|
::= { smEightPortCfgEntry 6 }
|
|
|
|
smEightPortCfgSpeedStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port speed of Switch Module 8."
|
|
::= { smEightPortCfgEntry 7 }
|
|
|
|
smEightPortCfgAvailSpeeds OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Available speed setting per port for Switch Module 8.
|
|
If there is more than one setting, the speeds are separated by a comma and then a space."
|
|
::= { smEightPortCfgEntry 8 }
|
|
|
|
smEightPortCfgMedia OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
copper(0),
|
|
serdes(1),
|
|
opticalShortHaul(32),
|
|
opticalLongHaul(48),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port media type of Switch Module 8."
|
|
::= { smEightPortCfgEntry 9 }
|
|
|
|
smEightPortCfgProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ethernet(16),
|
|
fibreChannel(32),
|
|
scalability(48),
|
|
infiniband(64),
|
|
pciExpress(80),
|
|
myrinet(112),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port protocol of Switch Module 8."
|
|
::= { smEightPortCfgEntry 10 }
|
|
|
|
smEightPortCfgWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The width of the port in terms of how many combined cables are present for Switch Module 8.
|
|
A value of 0 indicates this field is not applicable to the switch ports.
|
|
This data is also known as the lane count."
|
|
::= { smEightPortCfgEntry 11 }
|
|
|
|
smEightPortCfgCableLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The length (in meters) of the cable supported by this port for Switch Module 8.
|
|
A value of 0 indicates this field is not applicable to the switch ports."
|
|
::= { smEightPortCfgEntry 12 }
|
|
|
|
smEightPortCfgCableType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External cable type for this port, for example, active copper or passive fiber."
|
|
::= { smEightPortCfgEntry 13 }
|
|
|
|
smEightPortCfgVendorName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cable manufacturer."
|
|
::= { smEightPortCfgEntry 14 }
|
|
|
|
smEightPortCfgCompatibility OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
incompatible(0),
|
|
compatible(1),
|
|
compatibleNotRecommended(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compatibility of the external cable that is plugged into the port."
|
|
::= { smEightPortCfgEntry 15 }
|
|
|
|
smEightPortCfgDataRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sdr(0),
|
|
ddr(1),
|
|
qdr(2),
|
|
edr(3),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Data rate supported for this port."
|
|
::= { smEightPortCfgEntry 16 }
|
|
|
|
|
|
switchModNinePortCfg OBJECT IDENTIFIER ::= { switchPortCfg 9 }
|
|
|
|
smNinePortCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmNinePortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 9 port configuration information.
|
|
Note: This option is not supported on all I/O modules."
|
|
::= { switchModNinePortCfg 1 }
|
|
|
|
smNinePortCfgEntry OBJECT-TYPE
|
|
SYNTAX SmNinePortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 9 port configuration information table entry"
|
|
INDEX { smNinePortCfgIndex }
|
|
::= { smNinePortCfgTable 1 }
|
|
|
|
SmNinePortCfgEntry ::= SEQUENCE {
|
|
smNinePortCfgIndex INTEGER,
|
|
smNinePortCfgLabel OCTET STRING,
|
|
smNinePortCfgType INTEGER,
|
|
smNinePortCfgLinkSetting INTEGER,
|
|
smNinePortCfgLinkState INTEGER,
|
|
smNinePortCfgSpeedSetting OCTET STRING,
|
|
smNinePortCfgSpeedStatus OCTET STRING,
|
|
smNinePortCfgAvailSpeeds OCTET STRING,
|
|
smNinePortCfgMedia INTEGER,
|
|
smNinePortCfgProtocol INTEGER,
|
|
smNinePortCfgWidth INTEGER,
|
|
smNinePortCfgCableLength INTEGER,
|
|
smNinePortCfgCableType OCTET STRING,
|
|
smNinePortCfgVendorName OCTET STRING,
|
|
smNinePortCfgCompatibility INTEGER,
|
|
smNinePortCfgDataRate INTEGER
|
|
}
|
|
|
|
smNinePortCfgIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 9 port sequence index."
|
|
::= { smNinePortCfgEntry 1 }
|
|
|
|
smNinePortCfgLabel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 9 port label"
|
|
::= { smNinePortCfgEntry 2 }
|
|
|
|
smNinePortCfgType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unused(0),
|
|
externalPort(1),
|
|
externalManagementPort(2),
|
|
externalDualPort(3),
|
|
bladePort(4),
|
|
mmManagementPort(5),
|
|
uplinkPort(6),
|
|
interModulePort(7),
|
|
interModuleManagementPort(8),
|
|
interModuleDualPort(9),
|
|
interModuleExternalBridgePort(10),
|
|
interModuleDualInternalBridgePort(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 9 port type:
|
|
External port: This port is connected to external device and is for data traffic.
|
|
External management port: This port is solely for external management connection.
|
|
This port is not used for data traffic from remote to blades.
|
|
External dual port: This external port is used for both data traffic to blades as well as for management.
|
|
Blade port: This port is connected to the blade.
|
|
Management Module Management port: This port is connected to the Management Module.
|
|
Uplink port: This port is configured for up link functionality.
|
|
Inter-Module port: This port is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type.
|
|
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
|
|
The port type is either by design connected to another I/O Module, by user configured,
|
|
or by AMM setting the port type.
|
|
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
|
|
and management purposes. The port type is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type."
|
|
::= { smNinePortCfgEntry 3 }
|
|
|
|
smNinePortCfgLinkSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link setting for Switch Module 9."
|
|
::= { smNinePortCfgEntry 4 }
|
|
|
|
smNinePortCfgLinkState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1),
|
|
initialized(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link state of Switch Module 9."
|
|
::= { smNinePortCfgEntry 5 }
|
|
|
|
smNinePortCfgSpeedSetting OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the port speed using the data rate and duplex value. For examples:
|
|
100mf: 100Mbps in Half Duplex;
|
|
10gf: 10 Gbps in Full Duplex;
|
|
auto: The working speed of the physical port can be tuned automatically.
|
|
|
|
NOTE: Only the speeds from smNinePortCfgAvailSpeeds are applicable to setting
|
|
this mib object."
|
|
::= { smNinePortCfgEntry 6 }
|
|
|
|
smNinePortCfgSpeedStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port speed of Switch Module 9."
|
|
::= { smNinePortCfgEntry 7 }
|
|
|
|
smNinePortCfgAvailSpeeds OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Available speed setting per port for Switch Module 9.
|
|
If there is more than one setting, the speeds are separated by a comma and then a space."
|
|
::= { smNinePortCfgEntry 8 }
|
|
|
|
smNinePortCfgMedia OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
copper(0),
|
|
serdes(1),
|
|
opticalShortHaul(32),
|
|
opticalLongHaul(48),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port media type of Switch Module 9."
|
|
::= { smNinePortCfgEntry 9 }
|
|
|
|
smNinePortCfgProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ethernet(16),
|
|
fibreChannel(32),
|
|
scalability(48),
|
|
infiniband(64),
|
|
pciExpress(80),
|
|
myrinet(112),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port protocol of Switch Module 9."
|
|
::= { smNinePortCfgEntry 10 }
|
|
|
|
smNinePortCfgWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The width of the port in terms of how many combined cables are present for Switch Module 9.
|
|
A value of 0 indicates this field is not applicable to the switch ports.
|
|
This data is also known as the lane count."
|
|
::= { smNinePortCfgEntry 11 }
|
|
|
|
smNinePortCfgCableLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The length (in meters) of the cable supported by this port for Switch Module 9.
|
|
A value of 0 indicates this field is not applicable to the switch ports."
|
|
::= { smNinePortCfgEntry 12 }
|
|
|
|
smNinePortCfgCableType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External cable type for this port, for example, active copper or passive fiber."
|
|
::= { smNinePortCfgEntry 13 }
|
|
|
|
smNinePortCfgVendorName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cable manufacturer."
|
|
::= { smNinePortCfgEntry 14 }
|
|
|
|
smNinePortCfgCompatibility OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
incompatible(0),
|
|
compatible(1),
|
|
compatibleNotRecommended(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compatibility of the external cable that is plugged into the port."
|
|
::= { smNinePortCfgEntry 15 }
|
|
|
|
smNinePortCfgDataRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sdr(0),
|
|
ddr(1),
|
|
qdr(2),
|
|
edr(3),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Data rate supported for this port."
|
|
::= { smNinePortCfgEntry 16 }
|
|
|
|
|
|
switchModTenPortCfg OBJECT IDENTIFIER ::= { switchPortCfg 10 }
|
|
|
|
smTenPortCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmTenPortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 10 port configuration information.
|
|
Note: This option is not supported on all I/O modules."
|
|
::= { switchModTenPortCfg 1 }
|
|
|
|
smTenPortCfgEntry OBJECT-TYPE
|
|
SYNTAX SmTenPortCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 10 port configuration information table entry"
|
|
INDEX { smTenPortCfgIndex }
|
|
::= { smTenPortCfgTable 1 }
|
|
|
|
SmTenPortCfgEntry ::= SEQUENCE {
|
|
smTenPortCfgIndex INTEGER,
|
|
smTenPortCfgLabel OCTET STRING,
|
|
smTenPortCfgType INTEGER,
|
|
smTenPortCfgLinkSetting INTEGER,
|
|
smTenPortCfgLinkState INTEGER,
|
|
smTenPortCfgSpeedSetting OCTET STRING,
|
|
smTenPortCfgSpeedStatus OCTET STRING,
|
|
smTenPortCfgAvailSpeeds OCTET STRING,
|
|
smTenPortCfgMedia INTEGER,
|
|
smTenPortCfgProtocol INTEGER,
|
|
smTenPortCfgWidth INTEGER,
|
|
smTenPortCfgCableLength INTEGER,
|
|
smTenPortCfgCableType OCTET STRING,
|
|
smTenPortCfgVendorName OCTET STRING,
|
|
smTenPortCfgCompatibility INTEGER,
|
|
smTenPortCfgDataRate INTEGER
|
|
}
|
|
|
|
smTenPortCfgIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 10 port sequence index."
|
|
::= { smTenPortCfgEntry 1 }
|
|
|
|
smTenPortCfgLabel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 10 port label"
|
|
::= { smTenPortCfgEntry 2 }
|
|
|
|
smTenPortCfgType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unused(0),
|
|
externalPort(1),
|
|
externalManagementPort(2),
|
|
externalDualPort(3),
|
|
bladePort(4),
|
|
mmManagementPort(5),
|
|
uplinkPort(6),
|
|
interModulePort(7),
|
|
interModuleManagementPort(8),
|
|
interModuleDualPort(9),
|
|
interModuleExternalBridgePort(10),
|
|
interModuleDualInternalBridgePort(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module 10 port type:
|
|
External port: This port is connected to external device and is for data traffic.
|
|
External management port: This port is solely for external management connection.
|
|
This port is not used for data traffic from remote to blades.
|
|
External dual port: This external port is used for both data traffic to blades as well as for management.
|
|
Blade port: This port is connected to the blade.
|
|
Management Module Management port: This port is connected to the Management Module.
|
|
Uplink port: This port is configured for up link functionality.
|
|
Inter-Module port: This port is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type.
|
|
Inter-Module Management port: This port is connected to another I/O Module for management purpose.
|
|
The port type is either by design connected to another I/O Module, by user configured,
|
|
or by AMM setting the port type.
|
|
Inter-Module Dual port: The port is connected to another I/O Module and can be used for both data
|
|
and management purposes. The port type is either by design connected to another I/O Module,
|
|
by user configured, or by AMM setting the port type."
|
|
::= { smTenPortCfgEntry 3 }
|
|
|
|
smTenPortCfgLinkSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link setting for Switch Module 10."
|
|
::= { smTenPortCfgEntry 4 }
|
|
|
|
smTenPortCfgLinkState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1),
|
|
initialized(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port link state of Switch Module 10."
|
|
::= { smTenPortCfgEntry 5 }
|
|
|
|
smTenPortCfgSpeedSetting OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set the port speed using the data rate and duplex value. For examples:
|
|
100mf: 100Mbps in Half Duplex;
|
|
10gf: 10 Gbps in Full Duplex;
|
|
auto: The working speed of the physical port can be tuned automatically.
|
|
|
|
NOTE: Only the speeds from smTenPortCfgAvailSpeeds are applicable to setting
|
|
this mib object."
|
|
::= { smTenPortCfgEntry 6 }
|
|
|
|
smTenPortCfgSpeedStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current port speed of Switch Module 10."
|
|
::= { smTenPortCfgEntry 7 }
|
|
|
|
smTenPortCfgAvailSpeeds OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Available speed setting per port for Switch Module 10.
|
|
If there is more than one setting, the speeds are separated by a comma and then a space."
|
|
::= { smTenPortCfgEntry 8 }
|
|
|
|
smTenPortCfgMedia OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
copper(0),
|
|
serdes(1),
|
|
opticalShortHaul(32),
|
|
opticalLongHaul(48),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port media type of Switch Module 10."
|
|
::= { smTenPortCfgEntry 9 }
|
|
|
|
smTenPortCfgProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ethernet(16),
|
|
fibreChannel(32),
|
|
scalability(48),
|
|
infiniband(64),
|
|
pciExpress(80),
|
|
myrinet(112),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port protocol of Switch Module 10."
|
|
::= { smTenPortCfgEntry 10 }
|
|
|
|
smTenPortCfgWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The width of the port in terms of how many combined cables are present for Switch Module 10.
|
|
A value of 0 indicates this field is not applicable to the switch ports.
|
|
This data is also known as the lane count."
|
|
::= { smTenPortCfgEntry 11 }
|
|
|
|
smTenPortCfgCableLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The length (in meters) of the cable supported by this port for Switch Module 10.
|
|
A value of 0 indicates this field is not applicable to the switch ports."
|
|
::= { smTenPortCfgEntry 12 }
|
|
|
|
smTenPortCfgCableType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"External cable type for this port, for example, active copper or passive fiber."
|
|
::= { smTenPortCfgEntry 13 }
|
|
|
|
smTenPortCfgVendorName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The cable manufacturer."
|
|
::= { smTenPortCfgEntry 14 }
|
|
|
|
smTenPortCfgCompatibility OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
incompatible(0),
|
|
compatible(1),
|
|
compatibleNotRecommended(2),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Compatibility of the external cable that is plugged into the port."
|
|
::= { smTenPortCfgEntry 15 }
|
|
|
|
smTenPortCfgDataRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sdr(0),
|
|
ddr(1),
|
|
qdr(2),
|
|
edr(3),
|
|
notApplicable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Data rate supported for this port."
|
|
::= { smTenPortCfgEntry 16 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- RAID Controller config
|
|
-- ********************************************************************************
|
|
raidControllerConfig OBJECT IDENTIFIER ::= { switchModule 3 }
|
|
|
|
raidControllerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RaidControllerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RAID Controller control table."
|
|
::= { raidControllerConfig 1 }
|
|
|
|
raidControllerEntry OBJECT-TYPE
|
|
SYNTAX RaidControllerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RAID Controller control table entry."
|
|
INDEX { raidControllerIndex }
|
|
::= { raidControllerTable 1 }
|
|
|
|
RaidControllerEntry ::= SEQUENCE {
|
|
raidControllerIndex INTEGER,
|
|
raidControllerId INTEGER,
|
|
raidControllerExists INTEGER,
|
|
raidControllerPowerState INTEGER,
|
|
raidControllerMACAddress OCTET STRING,
|
|
raidControllerSasID OCTET STRING,
|
|
raidControllerPingRequest INTEGER
|
|
}
|
|
|
|
raidControllerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RAID Controller control table index.
|
|
This MIB object is for SAS Controller Modules only."
|
|
::= { raidControllerEntry 1 }
|
|
|
|
raidControllerId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module3(3),
|
|
module4(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The I/O Module numeric identifier for the SAS Controller Module.
|
|
This MIB object is for SAS Controller Modules only."
|
|
::= { raidControllerEntry 2 }
|
|
|
|
raidControllerExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the I/O Module specified for the RAID Controller
|
|
exists or not.
|
|
This MIB object is for SAS Controller Modules only."
|
|
::= { raidControllerEntry 3 }
|
|
|
|
raidControllerPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
shutdownInProgress(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the I/O Module is powered on or not.
|
|
This MIB object is for SAS Controller Modules only."
|
|
::= { raidControllerEntry 4 }
|
|
|
|
raidControllerMACAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The MAC address for the RAID Controller network interface.
|
|
This MIB object is for SAS Controller Modules only."
|
|
::= { raidControllerEntry 5 }
|
|
|
|
raidControllerSasID OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware VPD SAS ID for the RAID Controller network interface.
|
|
This MIB object is for SAS Controller Modules only."
|
|
::= { raidControllerEntry 6 }
|
|
|
|
raidControllerPingRequest OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sends a ping to the current IP address of the RAID Controller network interface.
|
|
This MIB object can not be set, if AMM grants I/O Module the Protected Mode
|
|
permission and the module goes into Protected Mode.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object
|
|
This MIB object is for SAS Controller Modules only."
|
|
::= { raidControllerEntry 7 }
|
|
|
|
raidControllerNetworkCfg OBJECT IDENTIFIER ::= { raidControllerConfig 2 }
|
|
|
|
rcCurrentIPInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcCurrentIPInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RAID Controller current IP table.
|
|
This MIB object is for SAS Controller Modules only."
|
|
::= { raidControllerNetworkCfg 1 }
|
|
|
|
rcCurrentIPInfoEntry OBJECT-TYPE
|
|
SYNTAX RcCurrentIPInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RAID Controller current IP table entry.
|
|
This MIB object is for SAS Controller Modules only."
|
|
INDEX { rcCurrentIPInfoIndex }
|
|
::= { rcCurrentIPInfoTable 1 }
|
|
|
|
RcCurrentIPInfoEntry ::= SEQUENCE {
|
|
rcCurrentIPInfoIndex INTEGER,
|
|
rcCurrentIPInfoId INTEGER,
|
|
rcCurrentIPInfoExists INTEGER,
|
|
rcCurrentIPInfoPowerState INTEGER,
|
|
rcCurrentIPAddr IpAddress,
|
|
rcCurrentSubnetMask IpAddress,
|
|
rcCurrentGateway IpAddress,
|
|
rcCurrentIPConfigMethod INTEGER,
|
|
rcCurrentRaidedVlanId INTEGER
|
|
}
|
|
|
|
rcCurrentIPInfoIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RAID Controller current IP table index.
|
|
This MIB object is for SAS Controller Modules only."
|
|
::= { rcCurrentIPInfoEntry 1 }
|
|
|
|
rcCurrentIPInfoId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module3(3),
|
|
module4(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The I/O Module numeric identifier for the RAID Controller.
|
|
This MIB object is for SAS Controller Modules only."
|
|
::= { rcCurrentIPInfoEntry 2 }
|
|
|
|
rcCurrentIPInfoExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the I/O Module exists or not.
|
|
This MIB object is for SAS Controller Modules only."
|
|
::= { rcCurrentIPInfoEntry 3 }
|
|
|
|
rcCurrentIPInfoPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
shutdownInProgress(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the I/O Module is powered on or not.
|
|
This MIB object is for SAS Controller Modules only."
|
|
::= { rcCurrentIPInfoEntry 4 }
|
|
|
|
rcCurrentIPAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current IP address for the RAID Controller network interface.
|
|
This MIB object is for SAS Controller Modules only."
|
|
::= { rcCurrentIPInfoEntry 5 }
|
|
|
|
|
|
rcCurrentSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current subnet mask for the RAID Controller network interface.
|
|
This MIB object is for SAS Controller Modules only."
|
|
::= { rcCurrentIPInfoEntry 6 }
|
|
|
|
rcCurrentGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current subnet mask for the RAID Controller network interface.
|
|
This MIB object is for SAS Controller Modules only."
|
|
::= { rcCurrentIPInfoEntry 7 }
|
|
|
|
rcCurrentIPConfigMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
static(1),
|
|
dhcp(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current IP gateway for the RAID Controller network interface.
|
|
This MIB object is for SAS Controller Modules only."
|
|
::= { rcCurrentIPInfoEntry 8 }
|
|
|
|
rcCurrentRaidedVlanId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current virtual LAN ID for the RAID Controller network interface.
|
|
This MIB object is for SAS Controller Modules only."
|
|
::= { rcCurrentIPInfoEntry 9 }
|
|
|
|
rcNewIPInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcNewIPInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RAID Controller new IP configuration table.
|
|
This MIB object is for SAS Controller Modules only.
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode."
|
|
::= { raidControllerNetworkCfg 2 }
|
|
|
|
rcNewIPInfoEntry OBJECT-TYPE
|
|
SYNTAX RcNewIPInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RAID Controller new IP configuration information table entry.
|
|
This MIB object is for SAS Controller Modules only.
|
|
NOTE: This MIB table is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode."
|
|
INDEX { rcNewIPInfoIndex }
|
|
::= { rcNewIPInfoTable 1 }
|
|
|
|
RcNewIPInfoEntry ::= SEQUENCE {
|
|
rcNewIPInfoIndex INTEGER,
|
|
rcNewIPInfoId INTEGER,
|
|
rcNewIPInfoExists INTEGER,
|
|
rcNewIPInfoPowerState INTEGER,
|
|
rcNewIPAddr IpAddress,
|
|
rcNewSubnetMask IpAddress,
|
|
rcNewGateway IpAddress,
|
|
rcNewIPConfigMethod INTEGER,
|
|
rcNewIPConfigEnableDisable INTEGER
|
|
}
|
|
|
|
rcNewIPInfoIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RAID Controller new IP configuration information index.
|
|
This MIB object is for SAS Controller Modules only.
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode."
|
|
::= { rcNewIPInfoEntry 1 }
|
|
|
|
rcNewIPInfoId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
module3(3),
|
|
module4(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The I/O Module numeric identifier for the RAID Controller.
|
|
This MIB object is for SAS Controller Modules only.
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode."
|
|
::= { rcNewIPInfoEntry 2 }
|
|
|
|
rcNewIPInfoExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the I/O Module exists or not.
|
|
This MIB object is for SAS Controller Modules only.
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode."
|
|
::= { rcNewIPInfoEntry 3 }
|
|
|
|
rcNewIPInfoPowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
shutdownInProgress(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the I/O Module is powered on or not.
|
|
This MIB object is for SAS Controller Modules only.
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode."
|
|
::= { rcNewIPInfoEntry 4 }
|
|
|
|
rcNewIPAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The new IP address for the RAID Controller network interface.
|
|
This MIB object is for SAS Controller Modules only. Before setting this object to a new value,
|
|
rcNewIpconfigEnableDisable object must first be set to disabled.
|
|
NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode
|
|
permission and the module goes into Protected Mode.
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode."
|
|
::= { rcNewIPInfoEntry 5 }
|
|
|
|
|
|
rcNewSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The new subnet mask for the RAID Controller network interface.
|
|
This MIB object is for SAS Controller Modules only. Before setting this object to a new value,
|
|
rcNewIpconfigEnableDisable object must first be set to disabled.
|
|
NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode
|
|
permission and the module goes into Protected Mode.
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode."
|
|
::= { rcNewIPInfoEntry 6 }
|
|
|
|
rcNewGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The new IP gateway for the RAID Controller network interface.
|
|
This MIB object is for SAS Controller Modules only. Before setting this object to a new value,
|
|
rcNewIpconfigEnableDisable object must first be set to disabled.
|
|
NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode
|
|
permission and the module goes into Protected Mode.
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode."
|
|
::= { rcNewIPInfoEntry 7 }
|
|
|
|
rcNewIPConfigMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
static(1),
|
|
dhcp(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The new IP configuration method for the RAID Controller network interface.
|
|
This MIB object is for SAS Controller Modules only. Before setting this object to a new value,
|
|
rcNewIpconfigEnableDisable object must first be set to disabled.
|
|
NOTE: The value 'DHCP' can not be used to set.
|
|
NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode
|
|
permission and the module goes into Protected Mode.
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode."
|
|
::= { rcNewIPInfoEntry 8 }
|
|
|
|
rcNewIPConfigEnableDisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A set command enables new IP configurations that have been defined.
|
|
A get command indicates whether new IP configurations that have been enabled.
|
|
NOTE: This MIB object can not be set if the AMM grants the I/O Module Protected Mode
|
|
permission and the module goes into Protected Mode.
|
|
NOTE: This MIB object is not applicable to modules that are running in Network Address
|
|
Translation (NAT) Mode."
|
|
::= { rcNewIPInfoEntry 11 }
|
|
|
|
chassisTopology OBJECT IDENTIFIER ::= { blades 4 }
|
|
|
|
chassisResponseVersion OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis response version."
|
|
::= { chassisTopology 1 }
|
|
|
|
chassisFlags OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
serverBlade(1),
|
|
rackOrStandAlone(0)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis flags.
|
|
1 = a server blade chassis, 0 = a rack or standalone chassis."
|
|
::= { chassisTopology 2 }
|
|
|
|
chassisName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the active MM as a null terminated string."
|
|
::= { chassisTopology 3 }
|
|
|
|
chassisNoOfFPsSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of fan packs (FPs) supported.
|
|
|
|
NOTE: Fan packs are also referred to as Power Module Cooling Devices."
|
|
::= { chassisTopology 18 }
|
|
|
|
chassisNoOfPBsSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of processor blades (PBs) supported."
|
|
::= { chassisTopology 19 }
|
|
|
|
chassisNoOfSMsSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of switch modules (SMs) supported."
|
|
::= { chassisTopology 20 }
|
|
|
|
chassisNoOfMMsSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of management modules (MMs) supported."
|
|
::= { chassisTopology 21 }
|
|
|
|
chassisNoOfPMsSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of power modules (PMs) supported."
|
|
::= { chassisTopology 22 }
|
|
|
|
chassisNoOfMTsSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of media trays (MTs) supported."
|
|
::= { chassisTopology 23 }
|
|
|
|
chassisNoOfBlowersSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of blowers supported.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { chassisTopology 24 }
|
|
|
|
chassisPBsInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blades that are installed on the chassis.
|
|
The blades are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of blades supported. If a blade is installed in a
|
|
bay, a 1 is present in the string in the position representing
|
|
the bay ID as read from left to right. For example, if blades
|
|
are installed in bays 1, 5, and 13, and 14 blades are supported,
|
|
the string would look like '10001000000010'."
|
|
::= { chassisTopology 25 }
|
|
|
|
chassisSMsInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The switch modules that are installed on the chassis.
|
|
The switch modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of switch modules supported. If a switch module is
|
|
installed in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if switch modules are installed in bays 1 and 3, and 4 switch modules
|
|
are supported, the string would look like '1011' for BladeCenter and
|
|
BladeCenter T and '1011000000' for BladeCenter H and BladeCenter HT."
|
|
::= { chassisTopology 29 }
|
|
|
|
chassisMMsInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The management modules that are installed on the chassis.
|
|
The management modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as the
|
|
number of management modules supported. If a management module is installed
|
|
in a bay, a 1 is present in the string in the position representing
|
|
the bay ID as read from left to right. For example, if a management module
|
|
is installed in bay 1, and 2 management modules are supported, the
|
|
string would look like '10'."
|
|
::= { chassisTopology 30 }
|
|
|
|
chassisPMsInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The power modules that are installed on the chassis.
|
|
The power modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of power modules supported. If a power module is
|
|
installed in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if power modules are installed in bays 1 and 3, and 4 power modules
|
|
are supported, the string would look like '1010'."
|
|
::= { chassisTopology 31 }
|
|
|
|
chassisMTInstalled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether at least one media tray (MT) is installed."
|
|
::= { chassisTopology 32 }
|
|
|
|
|
|
chassisBlowersInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blowers that are installed on the chassis.
|
|
The blowers are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of blowers supported. If a blower is installed in a
|
|
bay, a 1 is present in the string in the position representing
|
|
the bay ID as read from left to right. For example, if a blower
|
|
is installed in bay 1, and 2 blowers are supported, the string
|
|
would look like '10'.
|
|
|
|
NOTE: Blowers are also referred to as Chassis Cooling Devices."
|
|
::= { chassisTopology 33 }
|
|
|
|
chassisActiveMM OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The active management module (MM)."
|
|
::= { chassisTopology 34 }
|
|
|
|
chassisKVMOwner OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade that currently owns the keyboard/video/monitor (KVM).
|
|
0 = the KVM devices are owned by the management module."
|
|
::= { chassisTopology 35 }
|
|
|
|
chassisMediaTrayOwner OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The blade that currently owns the media tray.
|
|
0 = the media tray is owned by the management module."
|
|
::= { chassisTopology 36 }
|
|
|
|
chassisFPsInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The fan packs that are installed on the chassis.
|
|
The fan packs are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of fan packs supported. If a fan pack is
|
|
installed in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if fan packs are installed in bays 1 and 3, and 4 fan packs
|
|
are supported, the string would look like '1010'.
|
|
|
|
NOTE: Fan packs are also referred to as Power Module Cooling Devices."
|
|
::= { chassisTopology 37 }
|
|
|
|
chassisType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bladeCenterOrBladeCenterH(97),
|
|
bladeCenterTOrBladeCenterHT(98)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of the chassis. The BladeCenterS chassis and BladeCenterE are part of the
|
|
bladeCenterOrBladeCenterH type. This MIB object should be used in conjunction
|
|
with chassisSubType MIB object to determine the characteristic of the chassis."
|
|
::= { chassisTopology 38 }
|
|
|
|
chassisSubtype OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bladeCenterOrBladeCenterT(0),
|
|
bladeCenterHOrBladeCenterHT(2),
|
|
bladeCenterS(3),
|
|
bladeCenterE(4),
|
|
bladeCenterH(5),
|
|
bladeCenterT(32),
|
|
unknown(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The subtype of the chassis. This MIB object should be used in conjunction with
|
|
chassisType MIB object to determine the characteristic of the chassis."
|
|
::= { chassisTopology 39 }
|
|
|
|
-- ********************************************************************************
|
|
|
|
chassisNoOfFBsSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of Front Bezel (FBs) supported."
|
|
::= { chassisTopology 40 }
|
|
|
|
chassisNoOfAPsSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of Alarm Panel (APs) supported."
|
|
::= { chassisTopology 41 }
|
|
|
|
chassisNoOfNCsSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Number of Network Clocks (NCs) supported."
|
|
::= { chassisTopology 42 }
|
|
|
|
chassisNoOfMXsSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of Multiplexer Expansion modules (MXs) supported."
|
|
::= { chassisTopology 43 }
|
|
|
|
chassisNoOfMMIsSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of management module interposers (MMIs) supported."
|
|
::= { chassisTopology 44 }
|
|
|
|
chassisNoOfSMIsSupported OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of switch module interposers (SMIs) supported."
|
|
::= { chassisTopology 45 }
|
|
|
|
|
|
chassisNoOfFBsInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The return value of '1'indicates the front bezel is installed on the chassis.
|
|
The value of '0' indicates the front bezel is not installed."
|
|
::= { chassisTopology 46 }
|
|
|
|
chassisNoOfAPsInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The return value of '1'indicates the alarm panel is installed on the chassis.
|
|
The value of '0' indicates the alarm panel is not installed."
|
|
::= { chassisTopology 47 }
|
|
|
|
chassisNoOfNCsInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The network clock cards that are installed on the chassis.
|
|
The network clock cards are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of network clock cards supported. If a network clock
|
|
card is installed in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if a network clock card is installed in bays 1, and 2 network clock cards
|
|
are supported, the string would look like '10'."
|
|
::= { chassisTopology 48 }
|
|
|
|
chassisNoOfMXsInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Multiplexer Expansion Modules that are installed on the chassis.
|
|
The Multiplexer Expansion Modules are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as the number of
|
|
Multiplexer Expansion Modules supported. If a Multiplexer Expansion Module
|
|
is installed in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if Multiplexer Expansion Module is installed in bays 1, and 2 Multiplexer
|
|
Expansion Modules are supported, the string would look like '10'."
|
|
::= { chassisTopology 49 }
|
|
|
|
chassisNoOfMMIsInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The flex cables that are installed on the chassis.
|
|
The flex cables are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of flex cables supported. If a flex cable
|
|
is installed in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if flex cable is installed in bays 1, and 2 flex cables are
|
|
supported, the string would look like '10'."
|
|
::= { chassisTopology 50 }
|
|
|
|
chassisNoOfSMIsInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The interposers that are installed on the chassis.
|
|
The interposers are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of interposers supported. If an interposer
|
|
is installed in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if interposer is installed in bays 1, and 10 interposers are
|
|
supported, the string would look like '1000000000'."
|
|
::= { chassisTopology 51 }
|
|
|
|
chassisNoOfMTsInstalled OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The media trays that are installed on the chassis.
|
|
The media trays are listed as a bitmap. The bitmap is a
|
|
string containing a list of 1's and 0's that is as long as
|
|
the number of media trays supported. If a media tray is
|
|
installed in a bay, a 1 is present in the string in the position
|
|
representing the bay ID as read from left to right. For example,
|
|
if media trays are installed in bays 1, and 2 media trays are,
|
|
the string would look like '10'."
|
|
::= { chassisTopology 52 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
managementModule OBJECT IDENTIFIER ::= { blades 5 }
|
|
-- ********************************************************************************
|
|
|
|
mmStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MmStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the management module status.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { managementModule 1 }
|
|
|
|
mmStatusEntry OBJECT-TYPE
|
|
SYNTAX MmStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module status entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
INDEX { mmStatusIndex }
|
|
::= { mmStatusTable 1 }
|
|
|
|
MmStatusEntry ::= SEQUENCE {
|
|
mmStatusIndex INTEGER,
|
|
mmPresent INTEGER,
|
|
mmExtIpAddress IpAddress,
|
|
mmPrimary INTEGER,
|
|
mmHealthState INTEGER
|
|
}
|
|
|
|
mmStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module status index."
|
|
::= { mmStatusEntry 1 }
|
|
|
|
mmPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module current status."
|
|
::= { mmStatusEntry 2 }
|
|
|
|
mmExtIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module external IP address.
|
|
|
|
NOTE: The IPv6 addresses assigned to the AMM may be viewed
|
|
with the extEthernetInterfaceIPv6 objects"
|
|
::= { mmStatusEntry 3 }
|
|
|
|
mmPrimary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates if this Management module is a primary or not.
|
|
NOTE: If there is no standby MM, this value defaults to primary."
|
|
::= { mmStatusEntry 4 }
|
|
|
|
mmHealthState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
bad(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The health state for the management module.
|
|
0 = unknown, 1 = good, 2 = warning, 3 = bad."
|
|
::= { mmStatusEntry 5 }
|
|
|
|
-- ********************************************************************************
|
|
-- Storage Task for configuration
|
|
-- ********************************************************************************
|
|
storage OBJECT IDENTIFIER ::= { blades 6 }
|
|
|
|
storageStatus OBJECT IDENTIFIER ::= { storage 1 }
|
|
|
|
storageStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF StorageStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the storage module status.
|
|
For consistent results, view as a table and not as individual entries.
|
|
|
|
NOTE: This MIB object is for BCS only."
|
|
::= { storageStatus 1 }
|
|
|
|
storageStatusEntry OBJECT-TYPE
|
|
SYNTAX StorageStatusEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage Module Status Table Entry."
|
|
INDEX { storageStatusIndex }
|
|
::= { storageStatusTable 1 }
|
|
|
|
StorageStatusEntry ::= SEQUENCE {
|
|
storageStatusIndex INTEGER,
|
|
storageBayNumber OCTET STRING,
|
|
storageState INTEGER,
|
|
storageName OCTET STRING
|
|
}
|
|
|
|
storageStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage device status table index."
|
|
::= { storageStatusEntry 1 }
|
|
|
|
storageBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bay number of the Storage device."
|
|
::= { storageStatusEntry 2 }
|
|
|
|
storageState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
good(1),
|
|
warning(2),
|
|
critical(3),
|
|
notAvailable(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage device state."
|
|
::= { storageStatusEntry 3 }
|
|
|
|
storageName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the storage device."
|
|
::= { storageStatusEntry 4 }
|
|
|
|
storageConfiguration OBJECT IDENTIFIER ::= { storage 2 }
|
|
|
|
storageSwitchConfiguration OBJECT IDENTIFIER ::= { storageConfiguration 1 }
|
|
|
|
-- ********************************************************************************
|
|
-- Shows details about all possible zone configurations available on all SAS switches
|
|
-- and allows a user to select one and make it the active zone configuration
|
|
-- ********************************************************************************
|
|
|
|
storageSwitchZoneCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF StorageSwitchZoneCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of all the zone configurations stored on switch
|
|
modules. For consistent results, view as a table and
|
|
not as individual entries.
|
|
|
|
Before activating a new zone configuration via the switchActiveZoneCfg
|
|
object, a user must consider the following:
|
|
|
|
1) Changing the zone configuration may cause disruption in the storage
|
|
access of blades connected to this SAS Module. It is highly recommended
|
|
that you first ensure that the blades have completed all storage accesses.
|
|
You may want to shutdown the blade OS prior to changing your zone configuration.
|
|
|
|
2) When selecting a zone configuration, ensure that it is appropriate
|
|
for the number of SAS switches installed in your chassis. This can
|
|
be determined from the switchZoneCfgDescription text.
|
|
|
|
3) When selecting a zone configuration, ensure that it exists first on
|
|
all SAS switches. This can be determined by querying the
|
|
storageSwitchZoneCfgTable. In addition, for user-defined zone
|
|
configurations, even if the number is the same, ensure that the
|
|
actual zone configurations are identical or compatible. You will need
|
|
to use an application, such as the Switch Configuration Manager (SCM)
|
|
to verify this.
|
|
|
|
4) All SAS switches must be in operational state prior to activating a
|
|
new zone configuration. This can be determined by querying the
|
|
activeZoneCfgNumberBySwitch object and ensuring that none of the
|
|
2xx codes are returned."
|
|
::= { storageSwitchConfiguration 1 }
|
|
|
|
storageSwitchZoneCfgEntry OBJECT-TYPE
|
|
SYNTAX StorageSwitchZoneCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module Zone Configuration Management Entry."
|
|
INDEX { switchZoneCfgIndex }
|
|
::= { storageSwitchZoneCfgTable 1 }
|
|
|
|
StorageSwitchZoneCfgEntry ::= SEQUENCE {
|
|
switchZoneCfgIndex INTEGER,
|
|
switchZoneCfgBayNumber INTEGER,
|
|
switchZoneCfgNumber INTEGER,
|
|
switchZoneCfgStatus INTEGER,
|
|
switchZoneCfgType INTEGER,
|
|
switchZoneCfgName OCTET STRING,
|
|
switchZoneCfgDescription OCTET STRING,
|
|
switchZoneCfgDate OCTET STRING,
|
|
switchActiveZoneCfg INTEGER
|
|
}
|
|
|
|
switchZoneCfgIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch module zone configuration table index."
|
|
::= { storageSwitchZoneCfgEntry 1 }
|
|
|
|
switchZoneCfgBayNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric switch bay number."
|
|
::= { storageSwitchZoneCfgEntry 2 }
|
|
|
|
switchZoneCfgNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The zone configuration number, also referred to as the
|
|
configuration store number."
|
|
::= { storageSwitchZoneCfgEntry 3 }
|
|
|
|
switchZoneCfgStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nonActive(0),
|
|
active(1),
|
|
pending(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the zone configuration.
|
|
|
|
Only one configuration is 'Active', others are in 'nonActive'
|
|
status.
|
|
|
|
When a zone configuration is active on a switch, the status
|
|
may temporarily indicate pending(2) as it transitions from
|
|
nonActive(0) to active (1)."
|
|
::= { storageSwitchZoneCfgEntry 4 }
|
|
|
|
switchZoneCfgType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
userdefined(1),
|
|
predefined(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of the zone configuration. Predefined are read-only
|
|
static configurations, and userdefined are read-write
|
|
configurations that can be created and modified using the
|
|
Switch Configuration Manager application."
|
|
::= { storageSwitchZoneCfgEntry 5 }
|
|
|
|
switchZoneCfgName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A short descriptive name for the zone configuration."
|
|
::= { storageSwitchZoneCfgEntry 6 }
|
|
|
|
switchZoneCfgDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A detailed description for the zone configuration."
|
|
::= { storageSwitchZoneCfgEntry 7 }
|
|
|
|
switchZoneCfgDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The date the zone configuration was created."
|
|
::= { storageSwitchZoneCfgEntry 8 }
|
|
|
|
switchActiveZoneCfg OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An object used to activate a particular zone configuration.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object."
|
|
::= { storageSwitchZoneCfgEntry 9 }
|
|
|
|
-- ********************************************************************************
|
|
-- Shows which zone configuration is currently the active one on each SAS switch.
|
|
-- ********************************************************************************
|
|
|
|
storageSwitchActiveZoneCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF StorageSwitchActiveZoneCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table showing the zone configuration that is currently
|
|
active on a given switch module. For consistent results,
|
|
view as a table and not as individual entries."
|
|
::= { storageSwitchConfiguration 2 }
|
|
|
|
storageSwitchActiveZoneCfgEntry OBJECT-TYPE
|
|
SYNTAX StorageSwitchActiveZoneCfgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Active zone configurations Entry."
|
|
INDEX { activeZoneCfgIndex }
|
|
::= { storageSwitchActiveZoneCfgTable 1 }
|
|
|
|
StorageSwitchActiveZoneCfgEntry ::= SEQUENCE {
|
|
activeZoneCfgIndex INTEGER,
|
|
activeZoneCfgBayNumber OCTET STRING,
|
|
activeZoneCfgNumberBySwitch INTEGER,
|
|
activeZoneCfgNumberByMM INTEGER
|
|
}
|
|
|
|
activeZoneCfgIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Active zone configurations table index."
|
|
::= { storageSwitchActiveZoneCfgEntry 1 }
|
|
|
|
activeZoneCfgBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bay number of the switch module where active zone configurations exist."
|
|
::= { storageSwitchActiveZoneCfgEntry 2 }
|
|
|
|
activeZoneCfgNumberBySwitch OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The zone configuration number active on this SAS switch module
|
|
as reported by the switch module. If this number differs from the
|
|
value of the activeZoneCfgNumberByMM object for the same
|
|
switch, this may indicate a configuration problem.
|
|
|
|
The zone configuration number is also referred to as the zone
|
|
configuration store.
|
|
|
|
NOTE:
|
|
0 = No zone configuration is active on this I/O Module.
|
|
253 = I/O module is discovering zone information.
|
|
254 = I/O Module is not powered on or in a fault state.
|
|
255 = notApplicable."
|
|
::= { storageSwitchActiveZoneCfgEntry 3 }
|
|
|
|
activeZoneCfgNumberByMM OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The zone configuration number active on this SAS switch module
|
|
as known by the management module. If this number differs from the
|
|
value of the activeZoneCfgNumberBySwitch object for the same
|
|
switch, this may indicate a configuration problem.
|
|
|
|
The zone configuration number is also referred to as the zone
|
|
configuration store.
|
|
|
|
NOTE:
|
|
0 = No zone configuration is active on this I/O Module.
|
|
255 = notApplicable."
|
|
::= { storageSwitchActiveZoneCfgEntry 4 }
|
|
|
|
-- ********************************************************************************
|
|
-- A quick means of activating the same zone configuration on all SAS switches.
|
|
-- ********************************************************************************
|
|
|
|
switchZoneCfgActivation OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object provides a quick means of activating a valid zone
|
|
configuration on all active SAS switches. The zone configuration
|
|
to be activated is specified as the value of the SET and can be
|
|
obtained from the switchZoneCfgNumber object.
|
|
|
|
The zone configuration number is also referred to as the zone
|
|
configuration store.
|
|
|
|
Before activating a new zone configuration, a user must consider
|
|
the following:
|
|
|
|
1) Changing the zone configuration may cause disruption in the storage
|
|
access of blades connected to this SAS Module. It is highly recommended
|
|
that you first ensure that the blades have completed all storage accesses.
|
|
You may want to shutdown the blade OS prior to changing your zone configuration.
|
|
|
|
2) When selecting a zone configuration, ensure that it is appropriate
|
|
for the number of SAS switches installed in your chassis. This can
|
|
be determined from the switchZoneCfgDescription text.
|
|
|
|
3) When selecting a zone configuration, ensure that it exists first on
|
|
all SAS switches. This can be determined by querying the
|
|
storageSwitchZoneCfgTable. In addition, for user-defined zone
|
|
configurations, even if the number is the same, ensure that the
|
|
actual zone configurations are identical or compatible. You will need
|
|
to use an application, such as the Switch Configuration Manager (SCM)
|
|
to verify this.
|
|
|
|
4) All SAS switches must be in operational state prior to activating a
|
|
new zone configuration. This can be determined by querying the
|
|
activeZoneCfgNumberBySwitch object and ensuring that none of the
|
|
2xx codes are returned.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object.
|
|
|
|
If any of the switches are not activated, an error response
|
|
will be returned."
|
|
::= { storageSwitchConfiguration 3 }
|
|
|
|
-- ********************************************************************************
|
|
-- Firmware Image Information - currently for Iswitches that support multiple images
|
|
-- ********************************************************************************
|
|
firmwareInformation OBJECT IDENTIFIER ::= { blades 8 }
|
|
|
|
smFirmwareInformation OBJECT IDENTIFIER ::= { firmwareInformation 1 }
|
|
|
|
smFirmwareInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SmFirmwareInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module firmware image information.
|
|
This table is only applicable to modules that support multiple images"
|
|
::= { smFirmwareInformation 1 }
|
|
|
|
smFirmwareInfoEntry OBJECT-TYPE
|
|
SYNTAX SmFirmwareInfoEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module firmware image information table entry"
|
|
INDEX { smFirmwareInfoIndex }
|
|
::= { smFirmwareInfoTable 1 }
|
|
|
|
SmFirmwareInfoEntry ::= SEQUENCE {
|
|
smFirmwareInfoIndex INTEGER,
|
|
smFirmwareInfoModIndex INTEGER,
|
|
smFirmwareInfoImageIndex INTEGER,
|
|
smFirmwareInfoImageName OCTET STRING
|
|
}
|
|
|
|
smFirmwareInfoIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sequence index in the firmware table."
|
|
::= { smFirmwareInfoEntry 1 }
|
|
|
|
smFirmwareInfoModIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module number."
|
|
::= { smFirmwareInfoEntry 2 }
|
|
|
|
smFirmwareInfoImageIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module firmware image index."
|
|
::= { smFirmwareInfoEntry 3 }
|
|
|
|
smFirmwareInfoImageName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Switch Module firmware image name"
|
|
::= { smFirmwareInfoEntry 4 }
|
|
|
|
-- ********************************************************************************
|
|
-- Firmware update for MM, Switch modules, and blades
|
|
-- ********************************************************************************
|
|
firmwareUpdate OBJECT IDENTIFIER ::= { blades 9 }
|
|
|
|
firmwareUpdateTarget OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
managementModule(0),
|
|
switchModule1(11),
|
|
switchModule2(12),
|
|
switchModule3(13),
|
|
switchModule4(14),
|
|
switchModule5(15),
|
|
switchModule6(16),
|
|
switchModule7(17),
|
|
switchModule8(18),
|
|
switchModule9(19),
|
|
switchModule10(20),
|
|
blade1(31),
|
|
blade2(32),
|
|
blade3(33),
|
|
blade4(34),
|
|
blade5(35),
|
|
blade6(36),
|
|
blade7(37),
|
|
blade8(38),
|
|
blade9(39),
|
|
blade10(40),
|
|
blade11(41),
|
|
blade12(42),
|
|
blade13(43),
|
|
blade14(44),
|
|
unknown(255)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Target module whose firmware will be updated.
|
|
NOTE: Some switch modules do not allow firmware update.
|
|
When firmware update is attempted on those switch modules,
|
|
the agent will report an error."
|
|
::= { firmwareUpdate 1 }
|
|
|
|
firmwareUpdateTftpServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If flashing via the legacy method using a tftp server, then
|
|
set the IP address or host name of the TFTP server where
|
|
the firmware file resides. The address must be entered in a
|
|
dotted decimal IP string (e.g. 9.37.44.2).
|
|
|
|
NOTE: IPv6 numeric addresses must be enclosed with brackets
|
|
(e.g. [fe80::5652:ff:fe50:53b6])."
|
|
::= { firmwareUpdate 2 }
|
|
|
|
firmwareUpdateFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..254))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"File name of the firmware file."
|
|
::= { firmwareUpdate 3 }
|
|
|
|
firmwareUpdateStart OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1),
|
|
execute-with-reboot(2),
|
|
execute-nowait(3),
|
|
execute-with-reboot-nowait(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Start updating the firmware of the specified target module.
|
|
Using execute or execute-with-reboot will cause the SNMP client to
|
|
wait for the firmware update to complete.
|
|
Using execute-nowait or execute-with-reboot-nowait will not cause
|
|
the SNMP client to wait for the update to complete. Instead it will
|
|
flash the firmware in the background.
|
|
|
|
Note 1: If the execute-with-reboot or execute-with-reboot-nowait
|
|
option is selected, the target will reset after a successful flash.
|
|
This option is only valid if the firmwareUpdateTarget object is
|
|
set to managementModule.
|
|
Note 2: If flashing from a remote file, then both
|
|
firmwareUpdateServer and firmwareUpdateFileName must be
|
|
set. Otherwise if flashing via the legacy method using a tftp
|
|
server, then both firmwareUpdateTftpServer and
|
|
firmwareUpdateFileName must be set.
|
|
Note 3: Depending on the target, it might take up to several
|
|
minutes for the flash update to complete. Do not reset the
|
|
target until the control has been returned. At this point,
|
|
the results will be displayed.
|
|
Note 4: Use firmwareUpdateStatus to confirm the status of
|
|
the last firmware update initiated by SNMP method. The
|
|
Management Module must be restarted for the new firmware to
|
|
take affect.
|
|
Note 5: If data encryption is currently enabled on this MM,
|
|
and you update the MM firmware to a level which does not
|
|
support data encryption, you will lose all your configuration
|
|
settings as a result.
|
|
Note 6: Since some I/O Module types use the AMM TFTP server for
|
|
firmware file transfer during the firmware update process, the
|
|
tftpEnable MIB object must be set to enable prior to updating
|
|
the firmware for these modules.
|
|
Note 7: If IPv6 address(es) have been configured for one or more
|
|
interfaces/protocols/services on this AMM, when you update
|
|
the firmware to a level which does not support IPv6, all IPv6
|
|
connectivity will be lost, and services/interfaces for which an IPv6
|
|
address was configured may not function properly. You will be required
|
|
to reconfigure these services/interfaces.
|
|
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object."
|
|
::= { firmwareUpdate 4 }
|
|
|
|
firmwareUpdateStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Get the status of the last firmware update which was
|
|
initiated through SNMP method."
|
|
::= { firmwareUpdate 5 }
|
|
|
|
standbyFirmwareUpdateStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Get the current status of the firmware update for the standby AMM.
|
|
|
|
NOTE: This only applies to systems with a standby AMM."
|
|
::= { firmwareUpdate 6 }
|
|
|
|
firmwareImageNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the module can upload more than one image, an image
|
|
number must be specified after setting the firmware target.
|
|
Please refer to the firmwareInformation section."
|
|
::= { firmwareUpdate 7 }
|
|
|
|
firmwareActiveImage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the module can upload more than one image, an active image
|
|
number must be specified. Please refer to the firmwareInformation section.
|
|
NOTE: Value returned for the GET command is meaningless for this
|
|
MIB object."
|
|
::= { firmwareUpdate 8 }
|
|
|
|
firmwareUpdateServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..254))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the fully qualified remote location of the firmware
|
|
packet file. Use firmwareUpdateFileName to specify the filename.
|
|
|
|
A fully qualified remote location contains a supported
|
|
protocol followed by a colon and two slashes (//), userid and
|
|
password separated by a colon for login authentication, an
|
|
@ sign, followed by the hostname or IP address of the
|
|
server where the packet file resides, followed by an optional
|
|
port number to the hostname, and the full pathname to the file.
|
|
Note that if the port number is specified, it must be
|
|
separated with the hostname (or IP address) by a colon.
|
|
|
|
The AMM currently supports the following protocols:
|
|
TFTP, FTP, FTPS, HTTP and HTTPS.
|
|
|
|
The complete format of a fully qualified remote location is:
|
|
|
|
<protocol>://<userid:password>@<hostname:port>/<pathname>
|
|
|
|
An example of a fully qualified remote location can be:
|
|
ftp://USERID:PASSW0RD@192.168.0.2:30045/tmp
|
|
where the ftp protocol will be used for transferring the file in
|
|
this location, username is USERID, password is
|
|
PASSW0RD, host IP address is 192.168.0.2, port number is
|
|
30045, and the full pathname for the packet file is /tmp.
|
|
|
|
and firmwareUpdateFileName is set to: CNETCMUS.pkt
|
|
|
|
Some protocols do not need the username, password, and
|
|
the port number, so the minimum requirement for a fully
|
|
qualified location can be: <protocol>://<hostname>/<pathname>."
|
|
::= { firmwareUpdate 9 }
|
|
|
|
-- ********************************************************************************
|
|
-- mm Discovery
|
|
-- ********************************************************************************
|
|
remoteChassis OBJECT IDENTIFIER ::= { blades 10 }
|
|
|
|
remoteChassisTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RemoteChassisEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of remote chassis information."
|
|
::= { remoteChassis 1 }
|
|
|
|
remoteChassisEntry OBJECT-TYPE
|
|
SYNTAX RemoteChassisEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote chassis entry"
|
|
INDEX { remoteChassisIndex }
|
|
::= { remoteChassisTable 1 }
|
|
|
|
RemoteChassisEntry ::= SEQUENCE {
|
|
remoteChassisIndex INTEGER,
|
|
systemName OCTET STRING,
|
|
systemStatus INTEGER,
|
|
mmType OCTET STRING,
|
|
mmSerial OCTET STRING,
|
|
mmFru OCTET STRING,
|
|
mmIp OCTET STRING,
|
|
chassisSerial OCTET STRING,
|
|
chassisFru OCTET STRING,
|
|
chassisMachineTypeMode OCTET STRING,
|
|
chassisUuid OCTET STRING,
|
|
firmwareVersion OCTET STRING,
|
|
ipStatus INTEGER,
|
|
ipv6Addresses OCTET STRING
|
|
}
|
|
|
|
|
|
remoteChassisIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remote chassis discovery sequence index."
|
|
::= { remoteChassisEntry 1 }
|
|
|
|
systemName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System name for this discovery management module."
|
|
::= { remoteChassisEntry 2 }
|
|
|
|
systemStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
critical(0),
|
|
non-Critical(2),
|
|
system-Level(4),
|
|
unknown(9),
|
|
noResponse(170),
|
|
normal(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System status summary (chassis)."
|
|
::= { remoteChassisEntry 3 }
|
|
|
|
mmType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Service processor type."
|
|
::= { remoteChassisEntry 4 }
|
|
|
|
mmSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module serial number."
|
|
::= { remoteChassisEntry 5 }
|
|
|
|
mmFru OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Management module Field-Replaceable number."
|
|
::= { remoteChassisEntry 6 }
|
|
|
|
mmIp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPv4 compliant address of the management module."
|
|
::= { remoteChassisEntry 7}
|
|
|
|
|
|
chassisSerial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis serial number."
|
|
::= { remoteChassisEntry 8 }
|
|
|
|
chassisFru OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis Field-Replaceable number."
|
|
::= { remoteChassisEntry 9 }
|
|
|
|
chassisMachineTypeMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis machine type and model number."
|
|
::= { remoteChassisEntry 10 }
|
|
|
|
chassisUuid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Chassis unique identifier."
|
|
::= { remoteChassisEntry 11 }
|
|
|
|
|
|
firmwareVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Firmware version of the discovery management module."
|
|
::= { remoteChassisEntry 12 }
|
|
ipStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ipv4(1),
|
|
ipv6(2),
|
|
both(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A flag to state if IPv4 and IPv6 are enabled"
|
|
::= { remoteChassisEntry 13 }
|
|
ipv6Addresses OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPv6 addresses configured for the chassis."
|
|
::= { remoteChassisEntry 14 }
|
|
|
|
chassisDiscovery OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Discovery of remote Chassis.
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { remoteChassis 2}
|
|
|
|
-- ********************************************************************************
|
|
-- Local file management
|
|
-- ********************************************************************************
|
|
fileManagement OBJECT IDENTIFIER ::= { blades 11 }
|
|
|
|
fileTopology OBJECT IDENTIFIER ::= { fileManagement 1 }
|
|
|
|
currentDirectory OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the directory name for listing the requested files."
|
|
::= { fileTopology 1 }
|
|
|
|
fileDetailsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FileDetailsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of all the files in the specified directory.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { fileTopology 2 }
|
|
|
|
fileDetailsEntry OBJECT-TYPE
|
|
SYNTAX FileDetailsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"File details entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
INDEX { fileIndex }
|
|
::= { fileDetailsTable 1 }
|
|
|
|
FileDetailsEntry ::= SEQUENCE {
|
|
fileIndex INTEGER,
|
|
fileName OCTET STRING,
|
|
fileLastUpdate OCTET STRING,
|
|
fileSize OCTET STRING
|
|
}
|
|
|
|
fileIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"File sequence index."
|
|
::= { fileDetailsEntry 1 }
|
|
|
|
fileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"File name."
|
|
::= { fileDetailsEntry 2 }
|
|
|
|
fileLastUpdate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date of the latest file update."
|
|
::= { fileDetailsEntry 3 }
|
|
|
|
fileSize OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"File size in bytes."
|
|
::= { fileDetailsEntry 4 }
|
|
|
|
fileManagementCmd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This field will execute the selected operations on the files.
|
|
The following operation is supported:
|
|
DEL name - delete a file
|
|
|
|
Examples:
|
|
- to delete the file named switch.config in tftproot directory
|
|
set the value to 'DEL tftproot/switch.config'
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this
|
|
MIB object."
|
|
::= { fileManagement 3 }
|
|
|
|
fileSystemSpaceAvailable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This field displays the available space of the AMM file system."
|
|
::= { fileManagement 6 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- componentMonitors
|
|
-- ********************************************************************************
|
|
componentMonitors OBJECT IDENTIFIER ::= { blades 37 }
|
|
|
|
|
|
-- ********************************************************************************
|
|
-- componentMACAddressTable
|
|
-- ********************************************************************************
|
|
componentMACAddressTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ComponentMACAddressEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of MAC address VPD information for each component."
|
|
::= { componentMonitors 11 }
|
|
|
|
componentMACAddressEntry OBJECT-TYPE
|
|
SYNTAX ComponentMACAddressEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Component MAC address table entry"
|
|
INDEX { componentMACAddressTopologyPath, componentMACAddressIndex }
|
|
::= { componentMACAddressTable 1 }
|
|
|
|
ComponentMACAddressEntry ::= SEQUENCE {
|
|
componentMACAddressTopologyPath OCTET STRING,
|
|
componentMACAddressIndex INTEGER,
|
|
componentMACAddressName OCTET STRING,
|
|
componentMACAddress OCTET STRING
|
|
}
|
|
|
|
componentMACAddressTopologyPath OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..100))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unique identifier for a component in this table. The chassis and each
|
|
installed component is represented by a hardware topology tree, where
|
|
each node in the tree represents a component. The path to a particular
|
|
component consists of one or more <component>,<instance> pairs, where
|
|
each successive pair is a child of the previous parent pair.
|
|
|
|
As an example, the root of the tree is the chassis and is represented
|
|
by the pair 'CHASSIS, 1'. This pair indicates the first instance of
|
|
the chassis. If a blade is inserted in slot 4 of the chassis, its
|
|
topology path is 'CHASSIS, 1, BLADE, 4'. With this format, the
|
|
components in the chassis can be determined along with their relative
|
|
hierarchy to each other.
|
|
|
|
Note that this TP is preceded by a single octet that specifies the TP length.
|
|
This is required since this table is indexed with two indices and, therefore,
|
|
the TP length must be explicitly provided.
|
|
|
|
This component firmware table is indexed by this unique topology
|
|
path and the numeric designations for the components are:
|
|
|
|
CHASSIS, 0x01 Chassis
|
|
MM, 0x02 Management Module
|
|
BLADE, 0x03 Main system board of a blade
|
|
POWER, 0x04 Power Supply, Power Module, etc
|
|
COOLING, 0x05 Fan, blower, or other cooling device
|
|
IO_MODULE, 0x06 Has I/O interface, i.e. - switch or bridge
|
|
MEDIA, 0x07 Media device
|
|
PROCESSOR, 0x08 Any processor, processor module, etc
|
|
STORAGE, 0x09 Any type of storage device
|
|
EXPANSION, 0x0A Expansion Card (not covered by more specific type)
|
|
MEMORY, 0x0B Any memory device, module, etc
|
|
MFRU, 0x0C Managed FRU Device
|
|
PANEL, 0x0D Any sort of panel device, such as a front panel
|
|
BLADE_EXPANSION_MODULE, 0x0E Expansion option (BEM) such as PEU, BSE, etc
|
|
CARD_EXPANSION, 0x0F Expansion card, ie. daughter card
|
|
CARD_HS_EXPANSION, 0x10 High Speed Expansion card, ie. daughter card
|
|
INTERPOSER, 0x11 Interposer device
|
|
CLOCK, 0x12 Clock card
|
|
MUX, 0x13 Mulitplexer card
|
|
ADDIN, 0x14 cKVM card & other addin cards
|
|
STORAGE_MODULE, 0x15 Container of one or more Storage Devices
|
|
SYS_EXPANSION_CARD, 0x16 Management card
|
|
BATTERY, 0x17 A single battery
|
|
BATTERY_MODULE, 0x18 Container of one or more batteries
|
|
REAR_LED, 0x19 Rear LED card
|
|
MEMORY_BANK, 0x1A Memory banks
|
|
AIR_FILTER, 0x1B Filter mechanism (bezel)
|
|
SERIAL_PORT_MODULE, 0x1C Container of one or more serial ports
|
|
PARENT, 0x1D Reference to parent for multi-parent support
|
|
PHY_PORT, 0x1E Physical port
|
|
IO_EXPANDER, 0x1F RAID card
|
|
CABLE, 0x20 Cable/Interconnect
|
|
FAN_MUX 0x29 Fan multiplexer card"
|
|
::= { componentMACAddressEntry 1 }
|
|
|
|
componentMACAddressIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Each component may have one or more MAC address VPD values
|
|
associated with it, and this index object identifies the
|
|
particular instance."
|
|
::= { componentMACAddressEntry 2 }
|
|
|
|
componentMACAddressName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the component as a null terminated string."
|
|
::= { componentMACAddressEntry 3 }
|
|
|
|
componentMACAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The MAC address VPD value for this component and index. The
|
|
value is a null terminated string."
|
|
::= { componentMACAddressEntry 4 }
|
|
|
|
|
|
-- ************************************************************************
|
|
-- FFDC Service
|
|
-- ************************************************************************
|
|
|
|
serviceConfig OBJECT IDENTIFIER ::= { service 1 }
|
|
|
|
debugEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Disable/Enable AMM debugging with USB key by service personnel."
|
|
::= { serviceConfig 3 }
|
|
|
|
bladeServiceData OBJECT IDENTIFIER ::= { service 3 }
|
|
|
|
|
|
bladeServiceDataTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeServiceDataEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade service data information."
|
|
::= { bladeServiceData 1 }
|
|
|
|
bladeServiceDataEntry OBJECT-TYPE
|
|
SYNTAX BladeServiceDataEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade service data entry"
|
|
INDEX { serviceDataIndex }
|
|
::= { bladeServiceDataTable 1 }
|
|
|
|
|
|
BladeServiceDataEntry ::= SEQUENCE {
|
|
serviceDataIndex INTEGER,
|
|
serviceDataBladeId INTEGER,
|
|
serviceDataBladeExists INTEGER,
|
|
serviceDataBladePowerState INTEGER,
|
|
serviceDataBladeName OCTET STRING,
|
|
serviceDataBladeCapability INTEGER,
|
|
serviceDataDumpInitiate INTEGER,
|
|
serviceDataDumpRetrieve INTEGER,
|
|
serviceDataDumpCapabilityMask OCTET STRING,
|
|
serviceDataDumpInProgress INTEGER
|
|
}
|
|
|
|
serviceDataIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Blade service date index."
|
|
::= { bladeServiceDataEntry 1 }
|
|
|
|
serviceDataBladeId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
blade1(1),
|
|
blade2(2),
|
|
blade3(3),
|
|
blade4(4),
|
|
blade5(5),
|
|
blade6(6),
|
|
blade7(7),
|
|
blade8(8),
|
|
blade9(9),
|
|
blade10(10),
|
|
blade11(11),
|
|
blade12(12),
|
|
blade13(13),
|
|
blade14(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The numeric blade ID."
|
|
::= { bladeServiceDataEntry 2 }
|
|
|
|
serviceDataBladeExists OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(0),
|
|
true(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade specified exists or not."
|
|
::= { bladeServiceDataEntry 3 }
|
|
|
|
serviceDataBladePowerState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
standby(3),
|
|
hibernate(4),
|
|
unknown(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade specified is powered on or not.
|
|
If the AMM is experiencing a communication problem with the blade,
|
|
the state may be returned as unknown(255)"
|
|
::= { bladeServiceDataEntry 4 }
|
|
|
|
serviceDataBladeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the blade as a string."
|
|
::= { bladeServiceDataEntry 5 }
|
|
|
|
serviceDataBladeCapability OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Indicates whether the blade has the capability to trigger service data.
|
|
NOTE: This Mib object is deprecated and no longer supported.
|
|
Please see serviceDataBladeCapabilityMask OID"
|
|
::= { bladeServiceDataEntry 6 }
|
|
|
|
serviceDataDumpInitiate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
processorDump(1),
|
|
platformDump(2),
|
|
partitionDump(3),
|
|
serviceData(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Initiates a type of dump collection to be initiated for the blade.
|
|
|
|
NOTE: Not all blades support this, please check serviceDataDumpCapabilityMask
|
|
OID to see if the action is supported on this blade. Only one file can be moved
|
|
to the'/service' directory at a time, please look over fileManagement OID
|
|
to check if the file has been compeleted.
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object."
|
|
::= { bladeServiceDataEntry 7 }
|
|
|
|
serviceDataDumpRetrieve OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
processorDump(1),
|
|
platformDump(2),
|
|
partitionDump(3),
|
|
serviceData(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Retrieve a type of service data file from blade to AMM.
|
|
|
|
NOTE: This OID only is valid for the last four bit mask designations listed
|
|
in the serviceDataDumpCapabilityMask OID. Only one file can be moved to
|
|
the '/service' directory at a time, please look over fileManagement OID
|
|
to check if the file has been compeleted.
|
|
NOTE: Value returned for the GET command is meaningless
|
|
for this MIB object."
|
|
::= { bladeServiceDataEntry 8 }
|
|
|
|
serviceDataDumpCapabilityMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade has the capability to trigger service data and if so,
|
|
which operations are supported and whether the file can be transferred to the AMM
|
|
from the blade.
|
|
The values and meanings are as follows:
|
|
0000 0000 means this blade does not support any at all.
|
|
|
|
0000 0001 means this blade supports 'processor' type and the file remains on the blade.
|
|
0000 0010 means this blade supports 'platform' type and the file remains on the blade
|
|
0000 0100 means this blade supports 'partition' type and the file remians on the blade
|
|
|
|
0000 1000 means this blade supports 'processor' type and the file can be transferred to the AMM.
|
|
0001 0000 means this blade supports 'platform' type and the file can be transferred to the AMM.
|
|
0010 0000 means this blade supports 'partition' type and the file can be transferred to the AMM
|
|
0100 0000 means this blade supports 'serviceData' type and the file can be transferred to the AMM
|
|
|
|
For example, the returned value of 01111000 means this blade supports 'processor','platform',
|
|
'partition' and 'serviceData' types, and the file can be transferred to the AMM"
|
|
::= { bladeServiceDataEntry 9 }
|
|
|
|
serviceDataDumpInProgress OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
inProgress(1),
|
|
notInProgress(2),
|
|
unknown(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An indicator as to whether a blade dump is in progress for the specified blade.
|
|
This object ONLY applies to dumps that can be triggered by the AMM and where the
|
|
dump file is transferred to the AMM filesystem upon completion. See the
|
|
serviceDataDumpCapabilityMask object for support levels. The flag that this MIB object
|
|
represents will be set on when the IPMI command is sent to the blade indicating 'init dump'
|
|
and will be cleared upon receiving the valid dump file from the blade or the
|
|
creation of the text file indicating the problem encountered.
|
|
If it cannot be determined if the dump is in progress, the unknown(255) value is returned."
|
|
::= { bladeServiceDataEntry 10 }
|
|
|
|
|
|
bladeSystemReferenceCodes OBJECT IDENTIFIER ::= { bladeServiceData 3 }
|
|
bladeSysRefCodesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeSysRefCodesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of blade system reference codes."
|
|
::= { bladeSystemReferenceCodes 1 }
|
|
|
|
bladeSysRefCodesEntry OBJECT-TYPE
|
|
SYNTAX BladeSysRefCodesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Boot sequence entry"
|
|
INDEX { sysRefCodeIndex }
|
|
::= { bladeSysRefCodesTable 1 }
|
|
|
|
BladeSysRefCodesEntry ::= SEQUENCE {
|
|
sysRefCodeIndex INTEGER,
|
|
sysRefCodeBayNumber OCTET STRING,
|
|
sysRefCodeSequence INTEGER,
|
|
sysRefCode OCTET STRING,
|
|
sysRefCodeTimestamp OCTET STRING
|
|
}
|
|
|
|
sysRefCodeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System reference codes index."
|
|
::= { bladeSysRefCodesEntry 1 }
|
|
|
|
sysRefCodeBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bay number of the blade which has the system reference code."
|
|
::= { bladeSysRefCodesEntry 2 }
|
|
|
|
sysRefCodeSequence OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the blade specified exists or not."
|
|
::= { bladeSysRefCodesEntry 3 }
|
|
|
|
sysRefCode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unique ID and system reference code for the blade."
|
|
::= { bladeSysRefCodesEntry 4 }
|
|
|
|
sysRefCodeTimestamp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Timestamp of system reference code for the blade."
|
|
::= { bladeSysRefCodesEntry 5 }
|
|
|
|
bladeSysRefCodesDetailsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BladeSysRefCodesDetailsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of details of blade system reference codes."
|
|
::= { bladeSystemReferenceCodes 2 }
|
|
|
|
bladeSysRefCodesDetailsEntry OBJECT-TYPE
|
|
SYNTAX BladeSysRefCodesDetailsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Boot sequence entry"
|
|
INDEX { sysRefCodeDetailIndex }
|
|
::= { bladeSysRefCodesDetailsTable 1 }
|
|
|
|
BladeSysRefCodesDetailsEntry ::= SEQUENCE {
|
|
sysRefCodeDetailIndex INTEGER,
|
|
sysRefCodeDetailBayNumber OCTET STRING,
|
|
sysRefCodeDetailSRCSequence INTEGER,
|
|
sysRefCodeDetailSequence OCTET STRING,
|
|
sysRefCodeDetailDataString OCTET STRING
|
|
}
|
|
|
|
sysRefCodeDetailIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System reference codes index."
|
|
::= { bladeSysRefCodesDetailsEntry 1 }
|
|
|
|
sysRefCodeDetailBayNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The bay number of the blade which has the details
|
|
of system reference code."
|
|
::= { bladeSysRefCodesDetailsEntry 2 }
|
|
|
|
sysRefCodeDetailSRCSequence OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A sequence of the system reference codes for the blade."
|
|
::= { bladeSysRefCodesDetailsEntry 3 }
|
|
|
|
|
|
sysRefCodeDetailSequence OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A sequence of the detailed information of the system reference
|
|
codes for the blade."
|
|
::= { bladeSysRefCodesDetailsEntry 4 }
|
|
|
|
sysRefCodeDetailDataString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Detailed information of the system reference codes for the blade."
|
|
::= { bladeSysRefCodesDetailsEntry 5 }
|
|
|
|
|
|
serviceAdvisor OBJECT IDENTIFIER ::= { service 4 }
|
|
|
|
autoCallHomeSetup OBJECT IDENTIFIER ::= { serviceAdvisor 1 }
|
|
|
|
acceptLicenseAgreement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Accept Terms and Conditions of AMM Service Advisor. The user will have to accept the terms and conditions
|
|
before Service Advisor can send diagnostic data to IBM support personnel. If AMM configuration
|
|
is reset to defaults, the user will have to accept the terms and conditions again before they can
|
|
enable Service Advisor. For more information, please refer to the IBM BladeCenter User's Guide.
|
|
|
|
A GET of this object may return disabled(0) or enabled(1), depending upon the current state. However,
|
|
only enabled(1) is accepted on a SET in order to accept the license agreement. A SET of disabled(0)
|
|
will return noSuchValue and is not allowed."
|
|
::= {autoCallHomeSetup 1}
|
|
|
|
serviceAdvisorEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable IBM Support. The User Agreement must be accepted and the contact information
|
|
must be set before the IBM Support function of Service Advisor can be enabled."
|
|
::= {autoCallHomeSetup 2}
|
|
|
|
serviceSupportCenter OBJECT IDENTIFIER ::= {serviceAdvisor 2}
|
|
ibmSupportCenter OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The country code for the IBM Support Center. 2 character ISO country code."
|
|
::= {serviceSupportCenter 1}
|
|
contactInformation OBJECT IDENTIFIER ::= {serviceAdvisor 3}
|
|
|
|
companyName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
" The organization/company name of the contact person. 1-30 characters."
|
|
::= {contactInformation 1}
|
|
|
|
contactName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the contact person.1-30 characters."
|
|
::= {contactInformation 2}
|
|
|
|
phoneNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The phone of the contact person. 5-30 characters."
|
|
::= {contactInformation 3}
|
|
|
|
emailAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The email of the contact person. It must contain '@' and dot '.' in form userid@hostname (50 characters maximum).
|
|
The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters.
|
|
The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items.
|
|
Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters."
|
|
::= {contactInformation 4}
|
|
|
|
address OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The address of the machine location. The information in this field should be of sufficient detail to allow someone to
|
|
quickly find the chassis when necessary. 1-30 characters."
|
|
::= {contactInformation 5}
|
|
|
|
city OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The city of the machine location. 1-30 characters."
|
|
::= {contactInformation 6}
|
|
|
|
state OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The state of the machine location. 2-3 characters."
|
|
::= {contactInformation 7}
|
|
|
|
|
|
|
|
postalCode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The postal code of the location for this system. 1-9 characters, only alphanumeric characters are valid."
|
|
::= {contactInformation 8}
|
|
|
|
phoneNumberExt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The extension of the phone. 30 characters maximum."
|
|
::= {contactInformation 10}
|
|
|
|
altContactName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"(Optional) The name of the alternate contact person.1-30 characters."
|
|
::= {contactInformation 11}
|
|
|
|
altPhoneNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"(Optional) The phone of the alternate contact person. 5-30 characters."
|
|
::= {contactInformation 12}
|
|
|
|
altPhoneNumberExt OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"(Optional) The extension of the alternate phone. 30 characters maximum."
|
|
::= {contactInformation 13}
|
|
|
|
altEmailAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"(Optional) The email of the alternate contact person. It must contain '@' and dot '.' in form userid@hostname (50 characters maximum).
|
|
The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters.
|
|
The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items.
|
|
Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters."
|
|
::= {contactInformation 14}
|
|
|
|
machineLocPhone OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"(Optional) The contact phone number of the machine location. 5-30 characters."
|
|
::= {contactInformation 15}
|
|
|
|
httpProxyConfig OBJECT IDENTIFIER ::= {serviceAdvisor 4}
|
|
|
|
httpProxyEnable OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable of the HTTP Proxy. Select Enable to use the proxy for call home
|
|
connections from the AMM to IBM. HTTP Proxy is used by the AMM when it is not connected to the internet directly."
|
|
::= {httpProxyConfig 1}
|
|
|
|
httpProxyLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fully qualified host name or IP address of the HTTP Proxy. Maximum of 63 characters."
|
|
::= {httpProxyConfig 2}
|
|
|
|
httpProxyPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port number of the HTTP Proxy. An integer value from 1 to 65535."
|
|
::= {httpProxyConfig 3}
|
|
|
|
httpProxyUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User Name of the HTTP Proxy. A maximum of 30 characters string without spaces."
|
|
::= {httpProxyConfig 4}
|
|
|
|
httpProxyPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Password of the HTTP Proxy. A maximum of 15 characters string without spaces."
|
|
::= {httpProxyConfig 5}
|
|
|
|
activityLogs OBJECT IDENTIFIER ::= { serviceAdvisor 5}
|
|
|
|
|
|
activityLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ActivityLogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"
|
|
Table of Service Advisor Activity Log entries information. This table displays the last five
|
|
events that were generated by the system or user that are called home. The entries are displayed in
|
|
reverse chronological order (most recent call home entry first). For any events that happen with same
|
|
Date/Time, only one event will be called home. If a call home event that is already in the activity
|
|
log is triggered again on the same event source, it will not be called home again unless the prior entry has
|
|
been acknowledged as corrected or 120 hours (5 days) have passed since it initially occurred and was called home. "
|
|
::= { activityLogs 1 }
|
|
|
|
activityLogEntry OBJECT-TYPE
|
|
SYNTAX ActivityLogEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"
|
|
Activity Log table entry. Each entry has the result of the call-home attempt,
|
|
the service number assigned for the issue by IBM support, the event ID, event source, date and
|
|
time that event occured, and a text message.
|
|
"
|
|
INDEX { activityLogIndex }
|
|
::= { activityLogTable 1 }
|
|
|
|
|
|
ActivityLogEntry ::= SEQUENCE {
|
|
activityLogIndex INTEGER,
|
|
activityLogString OCTET STRING,
|
|
activityLogAcknowledge INTEGER,
|
|
activityLogAttribute OCTET STRING
|
|
}
|
|
|
|
|
|
activityLogIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Activity Log index number.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { activityLogEntry 1 }
|
|
|
|
activityLogString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string of data detailing one Activity Log entry. The text message is from the original entry in the event log.
|
|
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { activityLogEntry 2 }
|
|
|
|
activityLogAcknowledge OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
no(0),
|
|
yes(1) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The acknowledgement of one Activity Log entry as corrected. This field allows the users to set a reminder next to
|
|
certain events to indicate their awareness of the issue. Checking the acknowledge flag will not cause the event to be removed
|
|
from the log or close the ticket at IBM support. This log is not cleared, so the acknowledge flag can be used to indicate a problem
|
|
can be ignored. This field can be also used to override the 120 hour (5 day) filtering of reports via IBM Support or FTP/TFTP Server
|
|
of Service Data.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { activityLogEntry 3 }
|
|
|
|
activityLogAttribute OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"
|
|
A string of data detailing one Activity Log entry's attribute. It contains states of both calling IBM support and FTP/TFTP Server.
|
|
A PENDING indicates that the system is preparing for the event to be called home by collecting data about the systems state. A SUCCESS state
|
|
indicates that the problem was successfully transmitted to IBM support or FTP/TFTP Server. A DISABLED state indicates that Service Advisor
|
|
has disabled calling IBM Support or FTP/TFTP Server while the hardware event is detected. A NOT SENT state indicates that the serviceable
|
|
event was not sent to prevent the same event from being sent repeatedly. The FAILED state indicates that the attempt
|
|
to transmit the event information was not successful. Additional information may be found in the Event Log.
|
|
The service number is similar to a ticket number that can be used as a reference to the issue reported by the machine
|
|
when contacting IBM support. The event ID, event source, date and time are all information from the original entry in the event log.
|
|
The acknowledged as corrected field is a reminder to certain events to indicate their awareness of the issue.
|
|
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { activityLogEntry 4 }
|
|
|
|
-- ********************************************************************************
|
|
-- autoftp
|
|
-- ********************************************************************************
|
|
--
|
|
autoFTPSetup OBJECT IDENTIFIER ::= { service 5 }
|
|
|
|
autoFTPCallMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
ftp(1),
|
|
tftp(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This field specifies the automated problem reporting mode. Automated problem reporting mode allows the AMM to automatically put
|
|
service data to a specified server when a call home event is detected. For any call home events that happen with same Date/Time,
|
|
only one event will be reported. The system will also wait for an interval of 120 hours (5 days) before another identical event
|
|
can be sent for the same failed component."
|
|
::= { autoFTPSetup 1 }
|
|
|
|
autoFTPCallAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This field specifies the remote server address of FTP and TFTP. It should be fully qualified hostname or IP address."
|
|
::= { autoFTPSetup 2 }
|
|
autoFTPCallPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This field specifies the port on remote FTP/TFTP server for data transmission."
|
|
::= { autoFTPSetup 3 }
|
|
|
|
autoFTPCallUserID OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This field specifies the user account to login remote FTP server."
|
|
::= { autoFTPSetup 4 }
|
|
|
|
autoFTPCallPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This field specifies the password to login remote FTP server."
|
|
::= { autoFTPSetup 5 }
|
|
|
|
-- ********************************************************************************
|
|
-- Call Home Exclusion List
|
|
-- ********************************************************************************
|
|
|
|
callHomeExclusionEvents OBJECT IDENTIFIER ::= { service 6}
|
|
|
|
|
|
readCallHomeExclusionEventTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ReadCallHomeExclusionEventEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of Call Home Exclusion Event entries information."
|
|
::= { callHomeExclusionEvents 1 }
|
|
|
|
readCallHomeExclusionEventEntry OBJECT-TYPE
|
|
SYNTAX ReadCallHomeExclusionEventEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Call Home Exclusion Event table entry"
|
|
INDEX { readCallHomeExclusionEventIndex }
|
|
::= { readCallHomeExclusionEventTable 1 }
|
|
|
|
|
|
ReadCallHomeExclusionEventEntry ::= SEQUENCE {
|
|
readCallHomeExclusionEventIndex INTEGER,
|
|
readCallHomeExclusionEventID OCTET STRING
|
|
}
|
|
|
|
|
|
readCallHomeExclusionEventIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index number of one Call Home Exclusion Event.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { readCallHomeExclusionEventEntry 1 }
|
|
|
|
readCallHomeExclusionEventID OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Event ID of one Call Home Exclusion Event entry.
|
|
For consistent results, view as a table and not as individual entries."
|
|
::= { readCallHomeExclusionEventEntry 2 }
|
|
|
|
|
|
addCallHomeExclusionEvent OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Add one call home Event ID into the Call Home Exclusion List.
|
|
The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'.
|
|
If Service Advisor Terms and Conditions are accepted, an event can be added into the exclusion list.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { callHomeExclusionEvents 2}
|
|
|
|
rmCallHomeExclusionEvent OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remove one call home Event ID from the Call Home Exclusion List.
|
|
The Event ID is an 8-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'.
|
|
If Service Advisor Terms and Conditions are accepted, an event on the exclusion list can be removed.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { callHomeExclusionEvents 3}
|
|
rmAllCallHomeExclusionEvent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Remove all Event IDs from the Call Home Exclusion List.
|
|
If Service Advisor Terms and Conditions are accepted, events on the exclusion list can be removed.
|
|
|
|
NOTE: Value returned for the GET command is meaningless for this MIB object."
|
|
::= { callHomeExclusionEvents 4}
|
|
|
|
-- *************************************************************************
|
|
-- Scalable Complex Information
|
|
-- *************************************************************************
|
|
|
|
scalableComplexTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ScalableComplexEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of scalable complex information. This table provides information
|
|
and control actions related to the scalable complexes installed in the
|
|
chassis. Partition, node and port information and control are defined
|
|
in their own tables."
|
|
::= { scaling 1 }
|
|
|
|
scalableComplexEntry OBJECT-TYPE
|
|
SYNTAX ScalableComplexEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scalable complex information."
|
|
INDEX { scalableComplexIdentifier }
|
|
::= { scalableComplexTable 1 }
|
|
|
|
ScalableComplexEntry ::= SEQUENCE {
|
|
scalableComplexIdentifier INTEGER,
|
|
scalableComplexNumPartitions INTEGER,
|
|
scalableComplexNumNodes INTEGER,
|
|
scalableComplexPartStartSlot INTEGER,
|
|
scalableComplexPartNumNodes INTEGER,
|
|
scalableComplexAction INTEGER
|
|
}
|
|
|
|
scalableComplexIdentifier OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unique numeric identifier for a complex installed in the chassis."
|
|
::= { scalableComplexEntry 1 }
|
|
|
|
scalableComplexNumPartitions OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of partitions currently defined for this complex."
|
|
::= { scalableComplexEntry 2 }
|
|
|
|
scalableComplexNumNodes OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of nodes existing in this complex, regardless
|
|
of their assignment to any given partition. The physical
|
|
slot location of the nodes can be determined from the
|
|
scalableComplexNodeTable."
|
|
::= { scalableComplexEntry 3 }
|
|
|
|
scalableComplexPartStartSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The lowest slot number occupied by the nodes in the new partition that
|
|
is being created via the scalableComplexAction=create(3) action. This
|
|
object must be set prior to triggering the partition creation."
|
|
::= { scalableComplexEntry 4 }
|
|
|
|
scalableComplexPartNumNodes OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of nodes to be included in the new partition that is being
|
|
created via the scalableComplexAction=create(3) action. This object must
|
|
be set prior to triggering the partition creation."
|
|
::= { scalableComplexEntry 5 }
|
|
|
|
scalableComplexAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
clear(1),
|
|
autocreate(2),
|
|
create(3)
|
|
}
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object allows various actions to be taken in relation to a particular complex.
|
|
|
|
clear(1) - This clears all partition information related to the complex. Any nodes
|
|
associated with the complex are no longer assigned to any partitions.
|
|
All nodes in the complex must be powered off prior to attempting this
|
|
operation, otherwise, the action will fail.
|
|
|
|
autocreate(2) - This creates a single partition which includes all nodes associated
|
|
with the complex. Any other prior partition definitions must be
|
|
deleted prior to issuing this action, otherwise, the action will fail.
|
|
|
|
create(3) - This allows the creation of a partition within the complex. Prior to
|
|
triggering this action, the scalableComplexPartStartSlot and
|
|
scalableComplexPartNumNodes objects must be set first to identify the starting
|
|
slot number and number of nodes to be included in this new partition.
|
|
The nodes chosen for inclusion in this new partition must not be part of
|
|
another existing partition, otherwise, the action will fail."
|
|
::= { scalableComplexEntry 6 }
|
|
|
|
|
|
-- *************************************************************************
|
|
-- Scalable Complex Partition Information
|
|
-- *************************************************************************
|
|
|
|
scalableComplexPartitionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ScalableComplexPartitionEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of scalable complex partition information. This table provides information
|
|
and control actions related to the partitions defined across all of the
|
|
complexes installed in the chassis. Complex, node and port information
|
|
and control are defined in their own tables."
|
|
::= { scaling 2 }
|
|
|
|
scalableComplexPartitionEntry OBJECT-TYPE
|
|
SYNTAX ScalableComplexPartitionEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scalable complex partition information."
|
|
INDEX { scalableComplexId, scalableComplexPartitionIdentifier }
|
|
::= { scalableComplexPartitionTable 1 }
|
|
|
|
ScalableComplexPartitionEntry ::= SEQUENCE {
|
|
scalableComplexId INTEGER,
|
|
scalableComplexPartitionIdentifier INTEGER,
|
|
scalableComplexPartitionMode INTEGER,
|
|
scalableComplexPartitionNumNodes INTEGER,
|
|
scalableComplexPartitionStatus INTEGER,
|
|
scalableComplexPartitionAction INTEGER
|
|
}
|
|
|
|
|
|
scalableComplexId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unique numeric identifier for a complex installed in the chassis."
|
|
::= { scalableComplexPartitionEntry 1 }
|
|
|
|
scalableComplexPartitionIdentifier OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unique numeric identifier for a partition defined within a complex
|
|
installed in the chassis."
|
|
::= { scalableComplexPartitionEntry 2 }
|
|
|
|
scalableComplexPartitionMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
partition(1),
|
|
standalone(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The currently configured mode of this partition. It is recommended that
|
|
a partition be powered off prior to modification of the mode. In addition,
|
|
switching a partition mode to stand-alone will cause subsequent partition
|
|
actions to be ignored until the partition mode is restored."
|
|
::= { scalableComplexPartitionEntry 3 }
|
|
|
|
scalableComplexPartitionNumNodes OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of nodes currently defined for this partition."
|
|
::= { scalableComplexPartitionEntry 4 }
|
|
|
|
scalableComplexPartitionStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
poweredoff(1),
|
|
poweredon(2),
|
|
resetting(3),
|
|
invalid(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current power status of this partition when the partition has a
|
|
valid partition configuration. However, in the event the partition
|
|
reports a partition consitency check problem, the invalid state is provided."
|
|
::= { scalableComplexPartitionEntry 5 }
|
|
|
|
scalableComplexPartitionAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
delete(1),
|
|
poweron(2),
|
|
poweroff(3),
|
|
powercycle(4)
|
|
}
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object allows various actions to be taken in relation to a particular partition
|
|
in a given complex.
|
|
|
|
delete(1) - Deletes the partition from the complex. All nodes in the partition must
|
|
be powered off prior to attempting this operation, otherwise, the action
|
|
will fail.
|
|
|
|
poweron(2) - Powers up a powered off partition
|
|
|
|
poweroff(3) - Powers off an already powered on partition
|
|
|
|
powercycle(4) - Power cycles a partition"
|
|
::= { scalableComplexPartitionEntry 6 }
|
|
|
|
-- *************************************************************************
|
|
-- Scalable Complex Node Information
|
|
-- *************************************************************************
|
|
|
|
scalableComplexNodeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ScalableComplexNodeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of scalable complex node information. This table provides information
|
|
and control actions related to the nodes installed in the chassis.
|
|
Complex, partition and port information and control are defined
|
|
in their own tables."
|
|
::= { scaling 3 }
|
|
|
|
scalableComplexNodeEntry OBJECT-TYPE
|
|
SYNTAX ScalableComplexNodeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scalable complex node information."
|
|
INDEX { scalableComplexNodeSlot }
|
|
::= { scalableComplexNodeTable 1 }
|
|
|
|
ScalableComplexNodeEntry ::= SEQUENCE {
|
|
scalableComplexNodeSlot INTEGER,
|
|
scalableComplexNodeName OCTET STRING,
|
|
scalableComplexNodeType INTEGER,
|
|
scalableComplexNodeResources OCTET STRING,
|
|
scalableComplexNodeRole INTEGER,
|
|
scalableComplexNodeState INTEGER,
|
|
scalableComplexNodeUUID OCTET STRING,
|
|
scalableComplexNodeSerialNum OCTET STRING,
|
|
scalableComplexNodeNumPorts INTEGER,
|
|
scalableComplexNodeComplexID INTEGER,
|
|
scalableComplexNodePartitionID INTEGER,
|
|
scalableComplexNodeLogicalID INTEGER,
|
|
scalableComplexNodeAction INTEGER
|
|
}
|
|
|
|
scalableComplexNodeSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The base slot number where the node exists in the chassis."
|
|
::= { scalableComplexNodeEntry 1 }
|
|
|
|
scalableComplexNodeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(256))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The description string which uniquely identifies the blade."
|
|
::= { scalableComplexNodeEntry 2 }
|
|
|
|
scalableComplexNodeType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
processor(1),
|
|
memory(2),
|
|
io(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The general categorization of the node."
|
|
::= { scalableComplexNodeEntry 3 }
|
|
|
|
scalableComplexNodeResources OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(256))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string providing a summary overview of the resources provided by this node."
|
|
::= { scalableComplexNodeEntry 4 }
|
|
|
|
scalableComplexNodeRole OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
primary(1),
|
|
secondary(2),
|
|
unassigned(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates if the node is assigned to a partition, and if so, provides an
|
|
indication of whether the node is the primary node of the partition or not."
|
|
::= { scalableComplexNodeEntry 5 }
|
|
|
|
scalableComplexNodeState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
poweredoff(1),
|
|
poweredon(2),
|
|
resetting(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The physical power state of this node."
|
|
::= { scalableComplexNodeEntry 6 }
|
|
|
|
scalableComplexNodeUUID OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(256))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Universally Unique IDentifier (UUID) of this node, represented
|
|
as a 16 byte hex number."
|
|
::= { scalableComplexNodeEntry 7 }
|
|
|
|
scalableComplexNodeSerialNum OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(256))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of this node."
|
|
::= { scalableComplexNodeEntry 8 }
|
|
|
|
scalableComplexNodeNumPorts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of remote nodes that this node has links to."
|
|
::= { scalableComplexNodeEntry 9 }
|
|
|
|
scalableComplexNodeComplexID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For an assigned node, the identifier of the complex this node is related to.
|
|
For an unassigned node, this object has no meaning."
|
|
::= { scalableComplexNodeEntry 10 }
|
|
|
|
scalableComplexNodePartitionID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For an assigned node, the identifier of the partition this node is related to.
|
|
For an unassigned node, this object has no meaning."
|
|
::= { scalableComplexNodeEntry 11 }
|
|
|
|
scalableComplexNodeLogicalID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unique numeric identifier for this node, unique within the partition."
|
|
::= { scalableComplexNodeEntry 12 }
|
|
|
|
scalableComplexNodeAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
poweroff(1),
|
|
poweron(2)
|
|
}
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actions that can be applied to an unassigned node. The current state is
|
|
provided by the scalableComplexNodeState object."
|
|
::= { scalableComplexNodeEntry 14 }
|
|
|
|
|
|
-- *************************************************************************
|
|
-- Scalable Complex Node Port Information
|
|
-- *************************************************************************
|
|
|
|
scalableComplexNodePortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ScalableComplexNodePortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of scalable complex node port information which provides details
|
|
related to the port connectivity. Complex, partition and node information
|
|
and control are defined in their own tables."
|
|
::= { scaling 4 }
|
|
|
|
scalableComplexNodePortEntry OBJECT-TYPE
|
|
SYNTAX ScalableComplexNodePortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scalable complex node port information."
|
|
INDEX { scalableComplexNodePortSlot, scalableComplexNodePortNum }
|
|
::= { scalableComplexNodePortTable 1 }
|
|
|
|
ScalableComplexNodePortEntry ::= SEQUENCE {
|
|
scalableComplexNodePortSlot INTEGER,
|
|
scalableComplexNodePortNum INTEGER,
|
|
scalableComplexNodePortRemChkSum INTEGER,
|
|
scalableComplexNodePortRemNum INTEGER,
|
|
scalableComplexNodePortStatus INTEGER,
|
|
scalableComplexNodePortType INTEGER
|
|
}
|
|
|
|
scalableComplexNodePortSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The base slot number where the node exists in the chassis."
|
|
::= { scalableComplexNodePortEntry 1 }
|
|
|
|
scalableComplexNodePortNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port number of a port on this node. Note that this port
|
|
number is 0-based, but since it is used as the table index
|
|
(0 is not allowed), it will be presented as one more than the
|
|
actual port number."
|
|
::= { scalableComplexNodePortEntry 2 }
|
|
|
|
scalableComplexNodePortRemChkSum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The checksum of the remote port, used as a port identifier."
|
|
::= { scalableComplexNodePortEntry 3 }
|
|
|
|
scalableComplexNodePortRemNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The zero-based port number of the remote port."
|
|
::= { scalableComplexNodePortEntry 4 }
|
|
|
|
scalableComplexNodePortStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2),
|
|
unknown(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of the port."
|
|
::= { scalableComplexNodePortEntry 5 }
|
|
|
|
scalableComplexNodePortType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
qpi(1),
|
|
exa(2),
|
|
unknown(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port type."
|
|
::= { scalableComplexNodePortEntry 6 }
|
|
|
|
|
|
END
|
|
|