mibs/MIBS/junos/OPT-IF-MIB
2023-12-05 12:25:34 +01:00

6262 lines
197 KiB
Plaintext

OPT-IF-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Gauge32, Integer32,
Unsigned32, transmission
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, RowPointer, RowStatus, TruthValue
FROM SNMPv2-TC
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
ifIndex
FROM IF-MIB;
-- This is the MIB module for the OTN Interface objects.
optIfMibModule MODULE-IDENTITY
LAST-UPDATED "200308130000Z"
ORGANIZATION "IETF AToM MIB Working Group"
CONTACT-INFO
"WG charter:
http://www.ietf.org/html.charters/atommib-charter.html
Mailing Lists:
General Discussion: atommib@research.telcordia.com
To Subscribe: atommib-request@research.telcordia.com
Editor: Hing-Kam Lam
Postal: Lucent Technologies, Room 4C-616
101 Crawfords Corner Road
Holmdel, NJ 07733
Tel: +1 732 949 8338
Email: hklam@lucent.com"
DESCRIPTION
"The MIB module to describe pre-OTN and OTN interfaces.
Copyright (C) The Internet Society (2003). This version
of this MIB module is part of RFC 3591; see the RFC
itself for full legal notices."
REVISION "200308130000Z"
DESCRIPTION
"Initial version, published as RFC 3591."
::={ transmission 133 }
-- textual conventions
OptIfAcTI ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The trace identifier (TI) accepted at the receiver."
SYNTAX OCTET STRING (SIZE(64))
OptIfBitRateK ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates the index 'k' that is used to
represent a supported bit rate and the different
versions of OPUk, ODUk and OTUk.
Allowed values of k are defined in ITU-T G.709.
Currently allowed values in G.709 are:
k=1 represents an approximate bit rate of 2.5 Gbit/s,
k=2 represents an approximate bit rate of 10 Gbit/s,
k=3 represents an approximate bit rate of 40 Gbit/s."
SYNTAX Integer32
OptIfDEGM ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates the threshold level for declaring a Degraded Signal
defect (dDEG). A dDEG shall be declared if OptIfDEGM
consecutive bad PM Seconds are detected."
SYNTAX Unsigned32 (2..10)
OptIfDEGThr ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates the threshold level for declaring a performance
monitoring (PM) Second to be bad. A PM Second is declared bad if
the percentage of detected errored blocks in that second is
greater than or equal to OptIfDEGThr."
SYNTAX Unsigned32 (1..100)
OptIfDirectionality ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates the directionality of an entity."
SYNTAX INTEGER {
sink(1),
source(2),
bidirectional(3)
}
OptIfSinkOrSource ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates the directionality of an entity
that is allowed only to be a source or sink."
SYNTAX INTEGER {
sink(1),
source(2)
}
OptIfExDAPI ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The Destination Access Point Identifier (DAPI)
expected by the receiver."
SYNTAX OCTET STRING (SIZE(16))
OptIfExSAPI ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The Source Access Point Identifier (SAPI)
expected by the receiver."
SYNTAX OCTET STRING (SIZE(16))
OptIfIntervalNumber ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Uniquely identifies a 15-minute interval. The interval
identified by 1 is the most recently completed interval, and
the interval identified by n is the interval immediately
preceding the one identified by n-1."
SYNTAX Unsigned32 (1..96)
OptIfTIMDetMode ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Indicates the mode of the Trace Identifier Mismatch (TIM)
Detection function."
SYNTAX INTEGER {
off(1),
dapi(2),
sapi(3),
both(4)
}
OptIfTxTI ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The trace identifier (TI) transmitted."
SYNTAX OCTET STRING (SIZE(64))
-- object groups
optIfObjects OBJECT IDENTIFIER ::= { optIfMibModule 1 }
optIfConfs OBJECT IDENTIFIER ::= { optIfMibModule 2 }
optIfOTMn OBJECT IDENTIFIER ::= { optIfObjects 1 }
optIfPerfMon OBJECT IDENTIFIER ::= { optIfObjects 2 }
optIfOTSn OBJECT IDENTIFIER ::= { optIfObjects 3 }
optIfOMSn OBJECT IDENTIFIER ::= { optIfObjects 4 }
optIfOChGroup OBJECT IDENTIFIER ::= { optIfObjects 5 }
optIfOCh OBJECT IDENTIFIER ::= { optIfObjects 6 }
optIfOTUk OBJECT IDENTIFIER ::= { optIfObjects 7 }
optIfODUk OBJECT IDENTIFIER ::= { optIfObjects 8 }
optIfODUkT OBJECT IDENTIFIER ::= { optIfObjects 9 }
optIfGroups OBJECT IDENTIFIER ::= { optIfConfs 1 }
optIfCompl OBJECT IDENTIFIER ::= { optIfConfs 2 }
-- the optIfOTMn group
-- This group defines the OTM structure information of an
-- optical interface.
-- OTMn Table
optIfOTMnTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOTMnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OTMn structure information."
::= { optIfOTMn 1 }
optIfOTMnEntry OBJECT-TYPE
SYNTAX OptIfOTMnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains the OTMn structure
information of an optical interface."
INDEX { ifIndex }
::= { optIfOTMnTable 1 }
OptIfOTMnEntry ::=
SEQUENCE {
optIfOTMnOrder Unsigned32,
optIfOTMnReduced TruthValue,
optIfOTMnBitRates BITS,
optIfOTMnInterfaceType SnmpAdminString,
optIfOTMnTcmMax Unsigned32,
optIfOTMnOpticalReach INTEGER
}
optIfOTMnOrder OBJECT-TYPE
SYNTAX Unsigned32 (1..900)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the order of the OTM, which
represents the maximum number of wavelengths that can be
supported at the bit rate(s) supported on the interface."
::= { optIfOTMnEntry 1 }
optIfOTMnReduced OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates whether a reduced or full
functionality is supported at the interface. A value of
true means reduced. A value of false means full."
::= { optIfOTMnEntry 2 }
optIfOTMnBitRates OBJECT-TYPE
SYNTAX BITS { bitRateK1(0), bitRateK2(1), bitRateK3(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is a bit map representing the bit
rate or set of bit rates supported on the interface.
The meaning of each bit position is as follows:
bitRateK1(0) is set if the 2.5 Gbit/s rate is supported
bitRateK2(1) is set if the 10 Gbit/s rate is supported
bitRateK3(2) is set if the 40 Gbit/s rate is supported
Note that each bit position corresponds to one possible
value of the type OptIfBitRateK.
The default value of this attribute is system specific."
::= { optIfOTMnEntry 3 }
optIfOTMnInterfaceType OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the type of interface. The value of
this attribute will affect the behavior of the OTM with
respect to presence/absence of OTM Overhead Signal (OOS)
processing and TCM activation. For an IrDI interface,
there is no OOS processing and TCM activation is limited
to n levels as specified by a TCM level threshold.
This object contains two fields that are separated by
whitespace. The possible values are:
field 1: one of the 4-character ASCII strings
'IrDI' or 'IaDI'
field 2: free-form text consisting of printable
UTF-8 encoded characters
Note that field 2 is optional. If it is not present then there
is no requirement for trailing whitespace after field 1.
The default values are as follows:
field 1: 'IaDI'
field 2: an empty string."
::= { optIfOTMnEntry 4 }
optIfOTMnTcmMax OBJECT-TYPE
SYNTAX Unsigned32 (0..6)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the maximum number of TCM
levels allowed for any Optical Channel contained
in this OTM. A new TCM activation will be rejected
if the requested level is greater than the threshold.
If InterfaceType object specifies a type of 'IaDI'
for this OTM, then this attribute is irrelevant.
Possible values: unsigned integers in the range
from 0 to 6 inclusive.
Default value: 3."
::= { optIfOTMnEntry 5 }
optIfOTMnOpticalReach OBJECT-TYPE
SYNTAX INTEGER { intraOffice(1), shortHaul(2), longHaul(3),
veryLongHaul(4), ultraLongHaul(5) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the length the optical signal
may travel before requiring termination or regeneration.
The meaning of the enumeration are:
intraOffice(1) - intra-office (as defined in ITU-T G.957)
shortHaul(2) - short haul (as defined in ITU-T G.957)
longHaul(3) - long haul (as defined in ITU-T G.957)
veryLongHaul(4) - very long haul (as defined in ITU-T G.691)
ultraLongHaul(5)- ultra long haul (as defined in ITU-T G.691)"
::= { optIfOTMnEntry 6 }
-- the optIfPerfMon group
-- This group defines performance monitoring objects for all
-- layers.
-- PM interval table
optIfPerfMonIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfPerfMonIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of 15-minute performance monitoring interval
information."
::= { optIfPerfMon 1 }
optIfPerfMonIntervalEntry OBJECT-TYPE
SYNTAX OptIfPerfMonIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains 15-minute performance
monitoring interval information of an interface."
INDEX { ifIndex }
::= { optIfPerfMonIntervalTable 1 }
OptIfPerfMonIntervalEntry ::=
SEQUENCE {
optIfPerfMonCurrentTimeElapsed Gauge32,
optIfPerfMonCurDayTimeElapsed Gauge32,
optIfPerfMonIntervalNumIntervals Unsigned32,
optIfPerfMonIntervalNumInvalidIntervals Unsigned32
}
optIfPerfMonCurrentTimeElapsed OBJECT-TYPE
SYNTAX Gauge32 (0..900)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of seconds elapsed in the current 15-minute
performance monitoring interval.
If, for some reason, such as an adjustment in the NE's
time-of-day clock, the number of seconds elapsed exceeds
the maximum value, then the maximum value will be returned."
::= { optIfPerfMonIntervalEntry 1 }
optIfPerfMonCurDayTimeElapsed OBJECT-TYPE
SYNTAX Gauge32 (0..86400)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of seconds elapsed in the current 24-hour interval
performance monitoring period.
If, for some reason, such as an adjustment in the NE's
time-of-day clock, the number of seconds elapsed exceeds
the maximum value, then the maximum value will be returned."
::= { optIfPerfMonIntervalEntry 2 }
optIfPerfMonIntervalNumIntervals OBJECT-TYPE
SYNTAX Unsigned32 (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of 15-minute intervals for which performance
monitoring data is available. The number is the same for all
the associated sub layers of the interface.
An optical interface must be capable of supporting at least
n intervals, where n is defined as follows:
The minimum value of n is 4.
The default of n is 32.
The maximum value of n is 96.
The value of this object will be n unless performance
monitoring was (re-)started for the interface within the last
(n*15) minutes, in which case the value will be the number of
complete 15-minute intervals since measurement was
(re-)started."
::= { optIfPerfMonIntervalEntry 3 }
optIfPerfMonIntervalNumInvalidIntervals OBJECT-TYPE
SYNTAX Unsigned32 (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of intervals in the range from 0 to
optIfPerfMonIntervalNumIntervals for which no performance
monitoring data is available and/or the data is invalid."
::= { optIfPerfMonIntervalEntry 4 }
-- the optIfOTSn group
-- This group handles the configuration and performance
-- monitoring objects for OTS layers.
-- OTSn config table
optIfOTSnConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOTSnConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OTSn configuration information."
::= { optIfOTSn 1 }
optIfOTSnConfigEntry OBJECT-TYPE
SYNTAX OptIfOTSnConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OTSn configuration
information of an interface."
INDEX { ifIndex }
::= { optIfOTSnConfigTable 1 }
OptIfOTSnConfigEntry ::=
SEQUENCE {
optIfOTSnDirectionality OptIfDirectionality,
optIfOTSnAprStatus SnmpAdminString,
optIfOTSnAprControl SnmpAdminString,
optIfOTSnTraceIdentifierTransmitted OptIfTxTI,
optIfOTSnDAPIExpected OptIfExDAPI,
optIfOTSnSAPIExpected OptIfExSAPI,
optIfOTSnTraceIdentifierAccepted OptIfAcTI,
optIfOTSnTIMDetMode OptIfTIMDetMode,
optIfOTSnTIMActEnabled TruthValue,
optIfOTSnCurrentStatus BITS
}
optIfOTSnDirectionality OBJECT-TYPE
SYNTAX OptIfDirectionality
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the directionality of the entity."
::= { optIfOTSnConfigEntry 1 }
optIfOTSnAprStatus OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of the Automatic
Power Reduction (APR) function of the entity. Valid
values are 'on' and 'off'."
::= { optIfOTSnConfigEntry 2 }
optIfOTSnAprControl OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is a UTF-8 encoded string that specifies Automatic
Power Reduction (APR) control actions requested of this entity
(when written) and that returns the current APR control state
of this entity (when read). The values are implementation-defined.
Any implementation that instantiates this object must document the
set of values that it allows to be written, the set of values
that it will return, and what each of those values means."
::= { optIfOTSnConfigEntry 3 }
optIfOTSnTraceIdentifierTransmitted OBJECT-TYPE
SYNTAX OptIfTxTI
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The trace identifier transmitted.
This object is applicable when optIfOTSnDirectionality has the
value source(2) or bidirectional(3).
This object does not apply to reduced-capability systems (i.e.,
those for which optIfOTMnReduced has the value true(1)) or
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
has the value 'IrDI').
If no value is ever set by a management entity for the object
optIfOTSnTraceIdentifierTransmitted, system-specific default
value will be used. Any implementation that instantiates this
object must document the system-specific default value or how it
is derived."
::= { optIfOTSnConfigEntry 4 }
optIfOTSnDAPIExpected OBJECT-TYPE
SYNTAX OptIfExDAPI
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DAPI expected by the receiver.
This object is applicable when optIfOTSnDirectionality has the
value sink(1) or bidirectional(3). It has no effect if
optIfOTSnTIMDetMode has the value off(1) or sapi(3).
This object does not apply to reduced-capability systems (i.e.,
those for which optIfOTMnReduced has the value true(1)) or
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
has the value 'IrDI')."
::= { optIfOTSnConfigEntry 5 }
optIfOTSnSAPIExpected OBJECT-TYPE
SYNTAX OptIfExSAPI
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SAPI expected by the receiver.
This object is applicable when optIfOTSnDirectionality has the
value sink(1) or bidirectional(3). It has no effect if
optIfOTSnTIMDetMode has the value off(1) or dapi(2).
This object does not apply to reduced-capability systems (i.e.,
those for which optIfOTMnReduced has the value true(1)) or
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
has the value 'IrDI')."
::= { optIfOTSnConfigEntry 6 }
optIfOTSnTraceIdentifierAccepted OBJECT-TYPE
SYNTAX OptIfAcTI
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual trace identifier received.
This object is applicable when optIfOTSnDirectionality has the
value sink(1) or bidirectional(3). Its value is unspecified
if optIfOTSnCurrentStatus has either or both of the
losO(5) and los(6) bits set.
This object does not apply to reduced-capability systems (i.e.,
those for which optIfOTMnReduced has the value true(1)) or
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
has the value 'IrDI')."
::= { optIfOTSnConfigEntry 7 }
optIfOTSnTIMDetMode OBJECT-TYPE
SYNTAX OptIfTIMDetMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the mode of the Trace Identifier Mismatch (TIM)
Detection function. This object is applicable
when optIfOTSnDirectionality has the value sink(1)
or bidirectional(3). The default value is off(1).
This object does not apply to reduced-capability systems (i.e.,
those for which optIfOTMnReduced has the value true(1)) or
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
has the value 'IrDI').
The default value of this object is off(1)."
::= { optIfOTSnConfigEntry 8 }
optIfOTSnTIMActEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the Trace Identifier Mismatch (TIM)
Consequent Action function is enabled. This object
is applicable when optIfOTSnDirectionality has the
value sink(1) or bidirectional(3). It has no effect
when the value of optIfOTSnTIMDetMode is off(1).
This object does not apply to reduced-capability systems (i.e.,
those for which optIfOTMnReduced has the value true(1)) or
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
has the value 'IrDI').
The default value of this object is false(2)."
::= { optIfOTSnConfigEntry 9 }
optIfOTSnCurrentStatus OBJECT-TYPE
SYNTAX BITS {
bdiP(0),
bdiO(1),
bdi(2),
tim(3),
losP(4),
losO(5),
los(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the defect condition of the entity, if any.
This object is applicable when optIfOTSnDirectionality
has the value sink(1) or bidirectional(3). In
reduced-capability systems or at IrDI interfaces
the only bit position that may be set is los(6)."
::= { optIfOTSnConfigEntry 10 }
-- OTSn sink current table
-- Contains data for the current 15-minute performance monitoring
-- interval.
optIfOTSnSinkCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOTSnSinkCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OTSn sink performance monitoring information for
the current 15-minute interval."
::= { optIfOTSn 2 }
optIfOTSnSinkCurrentEntry OBJECT-TYPE
SYNTAX OptIfOTSnSinkCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OTSn sink performance
monitoring information of an interface for the current
15-minute interval."
INDEX { ifIndex }
::= { optIfOTSnSinkCurrentTable 1 }
OptIfOTSnSinkCurrentEntry ::=
SEQUENCE {
optIfOTSnSinkCurrentSuspectedFlag TruthValue,
optIfOTSnSinkCurrentInputPower Integer32,
optIfOTSnSinkCurrentLowInputPower Integer32,
optIfOTSnSinkCurrentHighInputPower Integer32,
optIfOTSnSinkCurrentLowerInputPowerThreshold Integer32,
optIfOTSnSinkCurrentUpperInputPowerThreshold Integer32,
optIfOTSnSinkCurrentOutputPower Integer32,
optIfOTSnSinkCurrentLowOutputPower Integer32,
optIfOTSnSinkCurrentHighOutputPower Integer32,
optIfOTSnSinkCurrentLowerOutputPowerThreshold Integer32,
optIfOTSnSinkCurrentUpperOutputPowerThreshold Integer32
}
optIfOTSnSinkCurrentSuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOTSnSinkCurrentEntry 1 }
optIfOTSnSinkCurrentInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The optical power monitored at the input."
::= { optIfOTSnSinkCurrentEntry 2 }
optIfOTSnSinkCurrentLowInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the input during the
current 15-minute interval."
::= { optIfOTSnSinkCurrentEntry 3 }
optIfOTSnSinkCurrentHighInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the input during the
current 15-minute interval."
::= { optIfOTSnSinkCurrentEntry 4 }
optIfOTSnSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The lower limit threshold on input power. If
optIfOTSnSinkCurrentInputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOTSnSinkCurrentEntry 5 }
optIfOTSnSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upper limit threshold on input power. If
optIfOTSnSinkCurrentInputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOTSnSinkCurrentEntry 6 }
optIfOTSnSinkCurrentOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The optical power monitored at the output."
::= { optIfOTSnSinkCurrentEntry 7 }
optIfOTSnSinkCurrentLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
current 15-minute interval."
::= { optIfOTSnSinkCurrentEntry 8 }
optIfOTSnSinkCurrentHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
current 15-minute interval."
::= { optIfOTSnSinkCurrentEntry 9 }
optIfOTSnSinkCurrentLowerOutputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The lower limit threshold on output power. If
optIfOTSnSinkCurrentOutputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOTSnSinkCurrentEntry 10 }
optIfOTSnSinkCurrentUpperOutputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upper limit threshold on output power. If
optIfOTSnSinkCurrentOutputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOTSnSinkCurrentEntry 11 }
-- OTSn sink interval table
-- Contains data for previous 15-minute performance monitoring
-- intervals.
optIfOTSnSinkIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOTSnSinkIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of historical OTSn sink performance monitoring
information."
::= { optIfOTSn 3 }
optIfOTSnSinkIntervalEntry OBJECT-TYPE
SYNTAX OptIfOTSnSinkIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OTSn sink performance
monitoring information of an interface during a particular
historical interval."
INDEX { ifIndex, optIfOTSnSinkIntervalNumber }
::= { optIfOTSnSinkIntervalTable 1 }
OptIfOTSnSinkIntervalEntry ::=
SEQUENCE {
optIfOTSnSinkIntervalNumber OptIfIntervalNumber,
optIfOTSnSinkIntervalSuspectedFlag TruthValue,
optIfOTSnSinkIntervalLastInputPower Integer32,
optIfOTSnSinkIntervalLowInputPower Integer32,
optIfOTSnSinkIntervalHighInputPower Integer32,
optIfOTSnSinkIntervalLastOutputPower Integer32,
optIfOTSnSinkIntervalLowOutputPower Integer32,
optIfOTSnSinkIntervalHighOutputPower Integer32
}
optIfOTSnSinkIntervalNumber OBJECT-TYPE
SYNTAX OptIfIntervalNumber
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies the interval."
::= { optIfOTSnSinkIntervalEntry 1 }
optIfOTSnSinkIntervalSuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOTSnSinkIntervalEntry 2 }
optIfOTSnSinkIntervalLastInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power monitored at the input during the
interval."
::= { optIfOTSnSinkIntervalEntry 3 }
optIfOTSnSinkIntervalLowInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the input during the
interval."
::= { optIfOTSnSinkIntervalEntry 4 }
optIfOTSnSinkIntervalHighInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the input during the
interval."
::= { optIfOTSnSinkIntervalEntry 5 }
optIfOTSnSinkIntervalLastOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power monitored at the output during the
interval."
::= { optIfOTSnSinkIntervalEntry 6 }
optIfOTSnSinkIntervalLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
interval."
::= { optIfOTSnSinkIntervalEntry 7 }
optIfOTSnSinkIntervalHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
interval."
::= { optIfOTSnSinkIntervalEntry 8 }
-- OTSn sink current day table
-- Contains data for the current 24-hour performance
-- monitoring interval.
optIfOTSnSinkCurDayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOTSnSinkCurDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OTSn sink performance monitoring information for
the current 24-hour interval."
::= { optIfOTSn 4 }
optIfOTSnSinkCurDayEntry OBJECT-TYPE
SYNTAX OptIfOTSnSinkCurDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OTSn sink performance
monitoring information of an interface for the current
24-hour interval."
INDEX { ifIndex }
::= { optIfOTSnSinkCurDayTable 1 }
OptIfOTSnSinkCurDayEntry ::=
SEQUENCE {
optIfOTSnSinkCurDaySuspectedFlag TruthValue,
optIfOTSnSinkCurDayLowInputPower Integer32,
optIfOTSnSinkCurDayHighInputPower Integer32,
optIfOTSnSinkCurDayLowOutputPower Integer32,
optIfOTSnSinkCurDayHighOutputPower Integer32
}
optIfOTSnSinkCurDaySuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOTSnSinkCurDayEntry 1 }
optIfOTSnSinkCurDayLowInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the input during the
current 24-hour interval."
::= { optIfOTSnSinkCurDayEntry 2 }
optIfOTSnSinkCurDayHighInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the input during the
current 24-hour interval."
::= { optIfOTSnSinkCurDayEntry 3 }
optIfOTSnSinkCurDayLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
current 24-hour interval."
::= { optIfOTSnSinkCurDayEntry 4 }
optIfOTSnSinkCurDayHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
current 24-hour interval."
::= { optIfOTSnSinkCurDayEntry 5 }
-- OTSn sink previous day table
-- Contains data for the previous 24-hour performance
-- monitoring interval.
optIfOTSnSinkPrevDayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOTSnSinkPrevDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OTSn sink performance monitoring information for
the previous 24-hour interval."
::= { optIfOTSn 5 }
optIfOTSnSinkPrevDayEntry OBJECT-TYPE
SYNTAX OptIfOTSnSinkPrevDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OTSn sink performance
monitoring information of an interface for the previous
24-hour interval."
INDEX { ifIndex }
::= { optIfOTSnSinkPrevDayTable 1 }
OptIfOTSnSinkPrevDayEntry ::=
SEQUENCE {
optIfOTSnSinkPrevDaySuspectedFlag TruthValue,
optIfOTSnSinkPrevDayLastInputPower Integer32,
optIfOTSnSinkPrevDayLowInputPower Integer32,
optIfOTSnSinkPrevDayHighInputPower Integer32,
optIfOTSnSinkPrevDayLastOutputPower Integer32,
optIfOTSnSinkPrevDayLowOutputPower Integer32,
optIfOTSnSinkPrevDayHighOutputPower Integer32
}
optIfOTSnSinkPrevDaySuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOTSnSinkPrevDayEntry 1 }
optIfOTSnSinkPrevDayLastInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power monitored at the input during the
previous 24-hour interval."
::= { optIfOTSnSinkPrevDayEntry 2 }
optIfOTSnSinkPrevDayLowInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the input during the
previous 24-hour interval."
::= { optIfOTSnSinkPrevDayEntry 3 }
optIfOTSnSinkPrevDayHighInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the input during the
previous 24-hour interval."
::= { optIfOTSnSinkPrevDayEntry 4 }
optIfOTSnSinkPrevDayLastOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power monitored at the output during the
previous 24-hour interval."
::= { optIfOTSnSinkPrevDayEntry 5 }
optIfOTSnSinkPrevDayLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
previous 24-hour interval."
::= { optIfOTSnSinkPrevDayEntry 6 }
optIfOTSnSinkPrevDayHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
previous 24-hour interval."
::= { optIfOTSnSinkPrevDayEntry 7 }
-- OTSn source current table
-- Contains data for the current 15-minute performance monitoring
-- interval.
optIfOTSnSrcCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOTSnSrcCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OTSn source performance monitoring information for
the current 15-minute interval."
::= { optIfOTSn 6 }
optIfOTSnSrcCurrentEntry OBJECT-TYPE
SYNTAX OptIfOTSnSrcCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OTSn source performance
monitoring information of an interface for the current
15-minute interval."
INDEX { ifIndex }
::= { optIfOTSnSrcCurrentTable 1 }
OptIfOTSnSrcCurrentEntry ::=
SEQUENCE {
optIfOTSnSrcCurrentSuspectedFlag TruthValue,
optIfOTSnSrcCurrentOutputPower Integer32,
optIfOTSnSrcCurrentLowOutputPower Integer32,
optIfOTSnSrcCurrentHighOutputPower Integer32,
optIfOTSnSrcCurrentLowerOutputPowerThreshold Integer32,
optIfOTSnSrcCurrentUpperOutputPowerThreshold Integer32,
optIfOTSnSrcCurrentInputPower Integer32,
optIfOTSnSrcCurrentLowInputPower Integer32,
optIfOTSnSrcCurrentHighInputPower Integer32,
optIfOTSnSrcCurrentLowerInputPowerThreshold Integer32,
optIfOTSnSrcCurrentUpperInputPowerThreshold Integer32
}
optIfOTSnSrcCurrentSuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOTSnSrcCurrentEntry 1 }
optIfOTSnSrcCurrentOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The optical power monitored at the output."
::= { optIfOTSnSrcCurrentEntry 2 }
optIfOTSnSrcCurrentLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
current 15-minute interval."
::= { optIfOTSnSrcCurrentEntry 3 }
optIfOTSnSrcCurrentHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
current 15-minute interval."
::= { optIfOTSnSrcCurrentEntry 4 }
optIfOTSnSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The lower limit threshold on output power. If
optIfOTSnSrcCurrentOutputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOTSnSrcCurrentEntry 5 }
optIfOTSnSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upper limit threshold on output power. If
optIfOTSnSrcCurrentOutputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOTSnSrcCurrentEntry 6 }
optIfOTSnSrcCurrentInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The optical power monitored at the input."
::= { optIfOTSnSrcCurrentEntry 7 }
optIfOTSnSrcCurrentLowInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the input during the
current 15-minute interval."
::= { optIfOTSnSrcCurrentEntry 8 }
optIfOTSnSrcCurrentHighInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the input during the
current 15-minute interval."
::= { optIfOTSnSrcCurrentEntry 9 }
optIfOTSnSrcCurrentLowerInputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The lower limit threshold on input power. If
optIfOTSnSrcCurrentInputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOTSnSrcCurrentEntry 10 }
optIfOTSnSrcCurrentUpperInputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upper limit threshold on input power. If
optIfOTSnSrcCurrentInputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOTSnSrcCurrentEntry 11 }
-- OTSn source interval table
-- Contains data for previous 15-minute performance monitoring
-- intervals.
optIfOTSnSrcIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOTSnSrcIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of historical OTSn source performance monitoring
information."
::= { optIfOTSn 7 }
optIfOTSnSrcIntervalEntry OBJECT-TYPE
SYNTAX OptIfOTSnSrcIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OTSn source performance
monitoring information of an interface during a particular
historical interval."
INDEX { ifIndex, optIfOTSnSrcIntervalNumber }
::= { optIfOTSnSrcIntervalTable 1 }
OptIfOTSnSrcIntervalEntry ::=
SEQUENCE {
optIfOTSnSrcIntervalNumber OptIfIntervalNumber,
optIfOTSnSrcIntervalSuspectedFlag TruthValue,
optIfOTSnSrcIntervalLastOutputPower Integer32,
optIfOTSnSrcIntervalLowOutputPower Integer32,
optIfOTSnSrcIntervalHighOutputPower Integer32,
optIfOTSnSrcIntervalLastInputPower Integer32,
optIfOTSnSrcIntervalLowInputPower Integer32,
optIfOTSnSrcIntervalHighInputPower Integer32
}
optIfOTSnSrcIntervalNumber OBJECT-TYPE
SYNTAX OptIfIntervalNumber
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies the interval."
::= { optIfOTSnSrcIntervalEntry 1 }
optIfOTSnSrcIntervalSuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOTSnSrcIntervalEntry 2 }
optIfOTSnSrcIntervalLastOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power monitored at the output during the
interval."
::= { optIfOTSnSrcIntervalEntry 3 }
optIfOTSnSrcIntervalLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
interval."
::= { optIfOTSnSrcIntervalEntry 4 }
optIfOTSnSrcIntervalHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
interval."
::= { optIfOTSnSrcIntervalEntry 5 }
optIfOTSnSrcIntervalLastInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power monitored at the input during the
interval."
::= { optIfOTSnSrcIntervalEntry 6 }
optIfOTSnSrcIntervalLowInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the input during the
interval."
::= { optIfOTSnSrcIntervalEntry 7 }
optIfOTSnSrcIntervalHighInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the input during the
interval."
::= { optIfOTSnSrcIntervalEntry 8 }
-- OTSn source current day table
-- Contains data for the current 24-hour performance
-- monitoring interval.
optIfOTSnSrcCurDayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOTSnSrcCurDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OTSn source performance monitoring information for
the current 24-hour interval."
::= { optIfOTSn 8 }
optIfOTSnSrcCurDayEntry OBJECT-TYPE
SYNTAX OptIfOTSnSrcCurDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OTSn source performance
monitoring information of an interface for the current
24-hour interval."
INDEX { ifIndex }
::= { optIfOTSnSrcCurDayTable 1 }
OptIfOTSnSrcCurDayEntry ::=
SEQUENCE {
optIfOTSnSrcCurDaySuspectedFlag TruthValue,
optIfOTSnSrcCurDayLowOutputPower Integer32,
optIfOTSnSrcCurDayHighOutputPower Integer32,
optIfOTSnSrcCurDayLowInputPower Integer32,
optIfOTSnSrcCurDayHighInputPower Integer32
}
optIfOTSnSrcCurDaySuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOTSnSrcCurDayEntry 1 }
optIfOTSnSrcCurDayLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
current 24-hour interval."
::= { optIfOTSnSrcCurDayEntry 2 }
optIfOTSnSrcCurDayHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
current 24-hour interval."
::= { optIfOTSnSrcCurDayEntry 3 }
optIfOTSnSrcCurDayLowInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the input during the
current 24-hour interval."
::= { optIfOTSnSrcCurDayEntry 4 }
optIfOTSnSrcCurDayHighInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the input during the
current 24-hour interval."
::= { optIfOTSnSrcCurDayEntry 5 }
-- OTSn source previous day table
-- Contains data for the previous 24-hour performance
-- monitoring interval.
optIfOTSnSrcPrevDayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOTSnSrcPrevDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OTSn source performance monitoring information for
the previous 24-hour interval."
::= { optIfOTSn 9 }
optIfOTSnSrcPrevDayEntry OBJECT-TYPE
SYNTAX OptIfOTSnSrcPrevDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OTSn source performance
monitoring information of an interface for the previous
24-hour interval."
INDEX { ifIndex }
::= { optIfOTSnSrcPrevDayTable 1 }
OptIfOTSnSrcPrevDayEntry ::=
SEQUENCE {
optIfOTSnSrcPrevDaySuspectedFlag TruthValue,
optIfOTSnSrcPrevDayLastOutputPower Integer32,
optIfOTSnSrcPrevDayLowOutputPower Integer32,
optIfOTSnSrcPrevDayHighOutputPower Integer32,
optIfOTSnSrcPrevDayLastInputPower Integer32,
optIfOTSnSrcPrevDayLowInputPower Integer32,
optIfOTSnSrcPrevDayHighInputPower Integer32
}
optIfOTSnSrcPrevDaySuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOTSnSrcPrevDayEntry 1 }
optIfOTSnSrcPrevDayLastOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power monitored at the output during the
previous 24-hour interval."
::= { optIfOTSnSrcPrevDayEntry 2 }
optIfOTSnSrcPrevDayLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
previous 24-hour interval."
::= { optIfOTSnSrcPrevDayEntry 3 }
optIfOTSnSrcPrevDayHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
previous 24-hour interval."
::= { optIfOTSnSrcPrevDayEntry 4 }
optIfOTSnSrcPrevDayLastInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power monitored at the input during the
previous 24-hour interval."
::= { optIfOTSnSrcPrevDayEntry 5 }
optIfOTSnSrcPrevDayLowInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the input during the
previous 24-hour interval."
::= { optIfOTSnSrcPrevDayEntry 6 }
optIfOTSnSrcPrevDayHighInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the input during the
previous 24-hour interval."
::= { optIfOTSnSrcPrevDayEntry 7 }
-- the optIfOMSn group
-- This group handles the configuration and performance monitoring
-- information for OMS layers.
-- OMSn config table
optIfOMSnConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOMSnConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OMSn configuration information."
::= { optIfOMSn 1 }
optIfOMSnConfigEntry OBJECT-TYPE
SYNTAX OptIfOMSnConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OMSn configuration
information of an interface."
INDEX { ifIndex }
::= { optIfOMSnConfigTable 1 }
OptIfOMSnConfigEntry ::=
SEQUENCE {
optIfOMSnDirectionality OptIfDirectionality,
optIfOMSnCurrentStatus BITS
}
optIfOMSnDirectionality OBJECT-TYPE
SYNTAX OptIfDirectionality
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the directionality of the entity."
::= { optIfOMSnConfigEntry 1 }
optIfOMSnCurrentStatus OBJECT-TYPE
SYNTAX BITS {
ssfP(0),
ssfO(1),
ssf(2),
bdiP(3),
bdiO(4),
bdi(5),
losP(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the defect condition of the entity, if any.
This object is applicable only to full capability
systems whose interface type is IaDI and for which
optIfOMSnDirectionality has the value sink(1) or
bidirectional(3)."
::= { optIfOMSnConfigEntry 2 }
-- OMSn sink current table
-- Contains data for the current 15-minute performance monitoring
-- interval.
optIfOMSnSinkCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOMSnSinkCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OMSn sink performance monitoring information for
the current 15-minute interval."
::= { optIfOMSn 2 }
optIfOMSnSinkCurrentEntry OBJECT-TYPE
SYNTAX OptIfOMSnSinkCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OMSn sink performance
monitoring information of an interface for the current
15-minute interval."
INDEX { ifIndex }
::= { optIfOMSnSinkCurrentTable 1 }
OptIfOMSnSinkCurrentEntry ::=
SEQUENCE {
optIfOMSnSinkCurrentSuspectedFlag TruthValue,
optIfOMSnSinkCurrentAggregatedInputPower Integer32,
optIfOMSnSinkCurrentLowAggregatedInputPower Integer32,
optIfOMSnSinkCurrentHighAggregatedInputPower Integer32,
optIfOMSnSinkCurrentLowerInputPowerThreshold Integer32,
optIfOMSnSinkCurrentUpperInputPowerThreshold Integer32,
optIfOMSnSinkCurrentOutputPower Integer32,
optIfOMSnSinkCurrentLowOutputPower Integer32,
optIfOMSnSinkCurrentHighOutputPower Integer32,
optIfOMSnSinkCurrentLowerOutputPowerThreshold Integer32,
optIfOMSnSinkCurrentUpperOutputPowerThreshold Integer32
}
optIfOMSnSinkCurrentSuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOMSnSinkCurrentEntry 1 }
optIfOMSnSinkCurrentAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The aggregated optical power of all the DWDM input
channels."
::= { optIfOMSnSinkCurrentEntry 2 }
optIfOMSnSinkCurrentLowAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest aggregated optical power of all the DWDM input
channels during the current 15-minute interval."
::= { optIfOMSnSinkCurrentEntry 3 }
optIfOMSnSinkCurrentHighAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest aggregated optical power of all the DWDM input
channels during the current 15-minute interval."
::= { optIfOMSnSinkCurrentEntry 4 }
optIfOMSnSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The lower limit threshold on aggregated input power. If
optIfOMSnSinkCurrentAggregatedInputPower drops to this value
or below, a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOMSnSinkCurrentEntry 5 }
optIfOMSnSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upper limit threshold on aggregated input power. If
optIfOMSnSinkCurrentAggregatedInputPower reaches or exceeds
this value, a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOMSnSinkCurrentEntry 6 }
optIfOMSnSinkCurrentOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The optical power monitored at the output."
::= { optIfOMSnSinkCurrentEntry 7 }
optIfOMSnSinkCurrentLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output
during the current 15-minute interval."
::= { optIfOMSnSinkCurrentEntry 8 }
optIfOMSnSinkCurrentHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output
during the current 15-minute interval."
::= { optIfOMSnSinkCurrentEntry 9 }
optIfOMSnSinkCurrentLowerOutputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The lower limit threshold on output power. If
optIfOMSnSinkCurrentOutputPower drops to this value
or below, a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOMSnSinkCurrentEntry 10 }
optIfOMSnSinkCurrentUpperOutputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upper limit threshold on output power. If
optIfOMSnSinkCurrentOutputPower reaches or exceeds
this value, a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOMSnSinkCurrentEntry 11 }
-- OMSn sink interval table
-- Contains data for previous 15-minute performance monitoring
-- intervals.
optIfOMSnSinkIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOMSnSinkIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of historical OMSn sink performance monitoring
information."
::= { optIfOMSn 3 }
optIfOMSnSinkIntervalEntry OBJECT-TYPE
SYNTAX OptIfOMSnSinkIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OMSn sink performance
monitoring information of an interface during a particular
historical interval."
INDEX { ifIndex, optIfOMSnSinkIntervalNumber }
::= { optIfOMSnSinkIntervalTable 1 }
OptIfOMSnSinkIntervalEntry ::=
SEQUENCE {
optIfOMSnSinkIntervalNumber OptIfIntervalNumber,
optIfOMSnSinkIntervalSuspectedFlag TruthValue,
optIfOMSnSinkIntervalLastAggregatedInputPower Integer32,
optIfOMSnSinkIntervalLowAggregatedInputPower Integer32,
optIfOMSnSinkIntervalHighAggregatedInputPower Integer32,
optIfOMSnSinkIntervalLastOutputPower Integer32,
optIfOMSnSinkIntervalLowOutputPower Integer32,
optIfOMSnSinkIntervalHighOutputPower Integer32
}
optIfOMSnSinkIntervalNumber OBJECT-TYPE
SYNTAX OptIfIntervalNumber
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies the interval."
::= { optIfOMSnSinkIntervalEntry 1 }
optIfOMSnSinkIntervalSuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOMSnSinkIntervalEntry 2 }
optIfOMSnSinkIntervalLastAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last aggregated optical power of all the DWDM input
channels during the interval."
::= { optIfOMSnSinkIntervalEntry 3 }
optIfOMSnSinkIntervalLowAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest aggregated optical power of all the DWDM input
channels during the interval."
::= { optIfOMSnSinkIntervalEntry 4 }
optIfOMSnSinkIntervalHighAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest aggregated optical power of all the DWDM input
channels during the interval."
::= { optIfOMSnSinkIntervalEntry 5 }
optIfOMSnSinkIntervalLastOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power at the output
during the interval."
::= { optIfOMSnSinkIntervalEntry 6 }
optIfOMSnSinkIntervalLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power at the output
during the interval."
::= { optIfOMSnSinkIntervalEntry 7 }
optIfOMSnSinkIntervalHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power at the output
during the interval."
::= { optIfOMSnSinkIntervalEntry 8 }
-- OMSn sink current day table
-- Contains data for the current 24-hour performance
-- monitoring interval.
optIfOMSnSinkCurDayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOMSnSinkCurDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OMSn sink performance monitoring information for
the current 24-hour interval."
::= { optIfOMSn 4 }
optIfOMSnSinkCurDayEntry OBJECT-TYPE
SYNTAX OptIfOMSnSinkCurDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OMSn sink performance
monitoring information of an interface for the current
24-hour interval."
INDEX { ifIndex }
::= { optIfOMSnSinkCurDayTable 1 }
OptIfOMSnSinkCurDayEntry ::=
SEQUENCE {
optIfOMSnSinkCurDaySuspectedFlag TruthValue,
optIfOMSnSinkCurDayLowAggregatedInputPower Integer32,
optIfOMSnSinkCurDayHighAggregatedInputPower Integer32,
optIfOMSnSinkCurDayLowOutputPower Integer32,
optIfOMSnSinkCurDayHighOutputPower Integer32
}
optIfOMSnSinkCurDaySuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOMSnSinkCurDayEntry 1 }
optIfOMSnSinkCurDayLowAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest aggregated optical power of all the DWDM input
channels during the current 24-hour interval."
::= { optIfOMSnSinkCurDayEntry 2 }
optIfOMSnSinkCurDayHighAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest aggregated optical power of all the DWDM input
channels during the current 24-hour interval."
::= { optIfOMSnSinkCurDayEntry 3 }
optIfOMSnSinkCurDayLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power at the output
during the current 24-hour interval."
::= { optIfOMSnSinkCurDayEntry 4 }
optIfOMSnSinkCurDayHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power at the output
during the current 24-hour interval."
::= { optIfOMSnSinkCurDayEntry 5 }
-- OMSn sink previous day table
-- Contains data for the previous 24-hour performance
-- monitoring interval.
optIfOMSnSinkPrevDayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOMSnSinkPrevDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OMSn sink performance monitoring information for
the previous 24-hour interval."
::= { optIfOMSn 5 }
optIfOMSnSinkPrevDayEntry OBJECT-TYPE
SYNTAX OptIfOMSnSinkPrevDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OMSn sink performance
monitoring information of an interface for the previous
24-hour interval."
INDEX { ifIndex }
::= { optIfOMSnSinkPrevDayTable 1 }
OptIfOMSnSinkPrevDayEntry ::=
SEQUENCE {
optIfOMSnSinkPrevDaySuspectedFlag TruthValue,
optIfOMSnSinkPrevDayLastAggregatedInputPower Integer32,
optIfOMSnSinkPrevDayLowAggregatedInputPower Integer32,
optIfOMSnSinkPrevDayHighAggregatedInputPower Integer32,
optIfOMSnSinkPrevDayLastOutputPower Integer32,
optIfOMSnSinkPrevDayLowOutputPower Integer32,
optIfOMSnSinkPrevDayHighOutputPower Integer32
}
optIfOMSnSinkPrevDaySuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOMSnSinkPrevDayEntry 1 }
optIfOMSnSinkPrevDayLastAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last aggregated optical power of all the DWDM input
channels during the previous 24-hour interval."
::= { optIfOMSnSinkPrevDayEntry 2 }
optIfOMSnSinkPrevDayLowAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest aggregated optical power of all the DWDM input
channels during the previous 24-hour interval."
::= { optIfOMSnSinkPrevDayEntry 3 }
optIfOMSnSinkPrevDayHighAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest aggregated optical power of all the DWDM input
channels during the previous 24-hour interval."
::= { optIfOMSnSinkPrevDayEntry 4 }
optIfOMSnSinkPrevDayLastOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power at the output
during the previous 24-hour interval."
::= { optIfOMSnSinkPrevDayEntry 5 }
optIfOMSnSinkPrevDayLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power at the output
during the previous 24-hour interval."
::= { optIfOMSnSinkPrevDayEntry 6 }
optIfOMSnSinkPrevDayHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power at the output
during the previous 24-hour interval."
::= { optIfOMSnSinkPrevDayEntry 7 }
-- OMSn source current table
-- Contains data for the current 15-minute performance monitoring
-- interval.
optIfOMSnSrcCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOMSnSrcCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OMSn source performance monitoring information for
the current 15-minute interval."
::= { optIfOMSn 6 }
optIfOMSnSrcCurrentEntry OBJECT-TYPE
SYNTAX OptIfOMSnSrcCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OMSn source performance
monitoring information of an interface for the current
15-minute interval."
INDEX { ifIndex }
::= { optIfOMSnSrcCurrentTable 1 }
OptIfOMSnSrcCurrentEntry ::=
SEQUENCE {
optIfOMSnSrcCurrentSuspectedFlag TruthValue,
optIfOMSnSrcCurrentOutputPower Integer32,
optIfOMSnSrcCurrentLowOutputPower Integer32,
optIfOMSnSrcCurrentHighOutputPower Integer32,
optIfOMSnSrcCurrentLowerOutputPowerThreshold Integer32,
optIfOMSnSrcCurrentUpperOutputPowerThreshold Integer32,
optIfOMSnSrcCurrentAggregatedInputPower Integer32,
optIfOMSnSrcCurrentLowAggregatedInputPower Integer32,
optIfOMSnSrcCurrentHighAggregatedInputPower Integer32,
optIfOMSnSrcCurrentLowerInputPowerThreshold Integer32,
optIfOMSnSrcCurrentUpperInputPowerThreshold Integer32
}
optIfOMSnSrcCurrentSuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOMSnSrcCurrentEntry 1 }
optIfOMSnSrcCurrentOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The optical power monitored at the output."
::= { optIfOMSnSrcCurrentEntry 2 }
optIfOMSnSrcCurrentLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
current 15-minute interval."
::= { optIfOMSnSrcCurrentEntry 3 }
optIfOMSnSrcCurrentHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
current 15-minute interval."
::= { optIfOMSnSrcCurrentEntry 4 }
optIfOMSnSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The lower limit threshold on output power. If
optIfOMSnSrcCurrentOutputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOMSnSrcCurrentEntry 5 }
optIfOMSnSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upper limit threshold on output power. If
optIfOMSnSrcCurrentOutputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOMSnSrcCurrentEntry 6 }
optIfOMSnSrcCurrentAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The aggregated optical power at the input."
::= { optIfOMSnSrcCurrentEntry 7 }
optIfOMSnSrcCurrentLowAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest aggregated optical power at the input
during the current 15-minute interval."
::= { optIfOMSnSrcCurrentEntry 8 }
optIfOMSnSrcCurrentHighAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest aggregated optical power at the input
during the current 15-minute interval."
::= { optIfOMSnSrcCurrentEntry 9 }
optIfOMSnSrcCurrentLowerInputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The lower limit threshold on aggregated input power. If
optIfOMSnSrcCurrentAggregatedInputPower drops to this value
or below, a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOMSnSrcCurrentEntry 10 }
optIfOMSnSrcCurrentUpperInputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upper limit threshold on aggregated input power. If
optIfOMSnSrcCurrentAggregatedInputPower reaches or exceeds
this value, a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOMSnSrcCurrentEntry 11 }
-- OMSn source interval table
-- Contains data for previous 15-minute performance monitoring
-- intervals.
optIfOMSnSrcIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOMSnSrcIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of historical OMSn source performance monitoring
information."
::= { optIfOMSn 7 }
optIfOMSnSrcIntervalEntry OBJECT-TYPE
SYNTAX OptIfOMSnSrcIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OMSn source performance
monitoring information of an interface during a particular
historical interval."
INDEX { ifIndex, optIfOMSnSrcIntervalNumber }
::= { optIfOMSnSrcIntervalTable 1 }
OptIfOMSnSrcIntervalEntry ::=
SEQUENCE {
optIfOMSnSrcIntervalNumber OptIfIntervalNumber,
optIfOMSnSrcIntervalSuspectedFlag TruthValue,
optIfOMSnSrcIntervalLastOutputPower Integer32,
optIfOMSnSrcIntervalLowOutputPower Integer32,
optIfOMSnSrcIntervalHighOutputPower Integer32,
optIfOMSnSrcIntervalLastAggregatedInputPower Integer32,
optIfOMSnSrcIntervalLowAggregatedInputPower Integer32,
optIfOMSnSrcIntervalHighAggregatedInputPower Integer32
}
optIfOMSnSrcIntervalNumber OBJECT-TYPE
SYNTAX OptIfIntervalNumber
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies the interval."
::= { optIfOMSnSrcIntervalEntry 1 }
optIfOMSnSrcIntervalSuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOMSnSrcIntervalEntry 2 }
optIfOMSnSrcIntervalLastOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power monitored at the output during the
interval."
::= { optIfOMSnSrcIntervalEntry 3 }
optIfOMSnSrcIntervalLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
interval."
::= { optIfOMSnSrcIntervalEntry 4 }
optIfOMSnSrcIntervalHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
interval."
::= { optIfOMSnSrcIntervalEntry 5 }
optIfOMSnSrcIntervalLastAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last aggregated optical power at the input
during the interval."
::= { optIfOMSnSrcIntervalEntry 6 }
optIfOMSnSrcIntervalLowAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest aggregated optical power at the input
during the interval."
::= { optIfOMSnSrcIntervalEntry 7 }
optIfOMSnSrcIntervalHighAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest aggregated optical power at the input
during the interval."
::= { optIfOMSnSrcIntervalEntry 8 }
-- OMSn source current day table
-- Contains data for the current 24-hour performance
-- monitoring interval.
optIfOMSnSrcCurDayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOMSnSrcCurDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OMSn source performance monitoring information for
the current 24-hour interval."
::= { optIfOMSn 8 }
optIfOMSnSrcCurDayEntry OBJECT-TYPE
SYNTAX OptIfOMSnSrcCurDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OMSn source performance
monitoring information of an interface for the current
24-hour interval."
INDEX { ifIndex }
::= { optIfOMSnSrcCurDayTable 1 }
OptIfOMSnSrcCurDayEntry ::=
SEQUENCE {
optIfOMSnSrcCurDaySuspectedFlag TruthValue,
optIfOMSnSrcCurDayLowOutputPower Integer32,
optIfOMSnSrcCurDayHighOutputPower Integer32,
optIfOMSnSrcCurDayLowAggregatedInputPower Integer32,
optIfOMSnSrcCurDayHighAggregatedInputPower Integer32
}
optIfOMSnSrcCurDaySuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOMSnSrcCurDayEntry 1 }
optIfOMSnSrcCurDayLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
current 24-hour interval."
::= { optIfOMSnSrcCurDayEntry 2 }
optIfOMSnSrcCurDayHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
current 24-hour interval."
::= { optIfOMSnSrcCurDayEntry 3 }
optIfOMSnSrcCurDayLowAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest aggregated optical power at the input
during the current 24-hour interval."
::= { optIfOMSnSrcCurDayEntry 4 }
optIfOMSnSrcCurDayHighAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest aggregated optical power at the input
during the current 24-hour interval."
::= { optIfOMSnSrcCurDayEntry 5 }
-- OMSn source previous day table
-- Contains data for the previous 24-hour performance
-- monitoring interval.
optIfOMSnSrcPrevDayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOMSnSrcPrevDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OMSn source performance monitoring information for
the previous 24-hour interval."
::= { optIfOMSn 9 }
optIfOMSnSrcPrevDayEntry OBJECT-TYPE
SYNTAX OptIfOMSnSrcPrevDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OMSn source performance
monitoring information of an interface for the previous
24-hour interval."
INDEX { ifIndex }
::= { optIfOMSnSrcPrevDayTable 1 }
OptIfOMSnSrcPrevDayEntry ::=
SEQUENCE {
optIfOMSnSrcPrevDaySuspectedFlag TruthValue,
optIfOMSnSrcPrevDayLastOutputPower Integer32,
optIfOMSnSrcPrevDayLowOutputPower Integer32,
optIfOMSnSrcPrevDayHighOutputPower Integer32,
optIfOMSnSrcPrevDayLastAggregatedInputPower Integer32,
optIfOMSnSrcPrevDayLowAggregatedInputPower Integer32,
optIfOMSnSrcPrevDayHighAggregatedInputPower Integer32
}
optIfOMSnSrcPrevDaySuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOMSnSrcPrevDayEntry 1 }
optIfOMSnSrcPrevDayLastOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power monitored at the output during the
previous 24-hour interval."
::= { optIfOMSnSrcPrevDayEntry 2 }
optIfOMSnSrcPrevDayLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
previous 24-hour interval."
::= { optIfOMSnSrcPrevDayEntry 3 }
optIfOMSnSrcPrevDayHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
previous 24-hour interval."
::= { optIfOMSnSrcPrevDayEntry 4 }
optIfOMSnSrcPrevDayLastAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last aggregated optical power at the input during the
previous 24-hour interval."
::= { optIfOMSnSrcPrevDayEntry 5 }
optIfOMSnSrcPrevDayLowAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest aggregated optical power at the input during the
previous 24-hour interval."
::= { optIfOMSnSrcPrevDayEntry 6 }
optIfOMSnSrcPrevDayHighAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest aggregated optical power at the input during the
previous 24-hour interval."
::= { optIfOMSnSrcPrevDayEntry 7 }
-- the optIfOChGroup group
-- This group handles the configuration and performance monitoring
-- information for OChGroup layers.
-- OChGroup config table
optIfOChGroupConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOChGroupConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OChGroup configuration information."
::= { optIfOChGroup 1 }
optIfOChGroupConfigEntry OBJECT-TYPE
SYNTAX OptIfOChGroupConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OChGroup configuration
information of an interface."
INDEX { ifIndex }
::= { optIfOChGroupConfigTable 1 }
OptIfOChGroupConfigEntry ::=
SEQUENCE {
optIfOChGroupDirectionality OptIfDirectionality
}
optIfOChGroupDirectionality OBJECT-TYPE
SYNTAX OptIfDirectionality
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the directionality of the entity."
::= { optIfOChGroupConfigEntry 1 }
-- OChGroup sink current table
-- Contains data for the current 15-minute performance monitoring
-- interval.
optIfOChGroupSinkCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOChGroupSinkCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OChGroup sink performance monitoring information for
the current 15-minute interval."
::= { optIfOChGroup 2 }
optIfOChGroupSinkCurrentEntry OBJECT-TYPE
SYNTAX OptIfOChGroupSinkCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OChGroup sink performance
monitoring information of an interface for the current
15-minute interval."
INDEX { ifIndex }
::= { optIfOChGroupSinkCurrentTable 1 }
OptIfOChGroupSinkCurrentEntry ::=
SEQUENCE {
optIfOChGroupSinkCurrentSuspectedFlag TruthValue,
optIfOChGroupSinkCurrentAggregatedInputPower Integer32,
optIfOChGroupSinkCurrentLowAggregatedInputPower Integer32,
optIfOChGroupSinkCurrentHighAggregatedInputPower Integer32,
optIfOChGroupSinkCurrentLowerInputPowerThreshold Integer32,
optIfOChGroupSinkCurrentUpperInputPowerThreshold Integer32,
optIfOChGroupSinkCurrentOutputPower Integer32,
optIfOChGroupSinkCurrentLowOutputPower Integer32,
optIfOChGroupSinkCurrentHighOutputPower Integer32,
optIfOChGroupSinkCurrentLowerOutputPowerThreshold Integer32,
optIfOChGroupSinkCurrentUpperOutputPowerThreshold Integer32
}
optIfOChGroupSinkCurrentSuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOChGroupSinkCurrentEntry 1 }
optIfOChGroupSinkCurrentAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The aggregated optical power of all the DWDM input
channels in the OChGroup."
::= { optIfOChGroupSinkCurrentEntry 2 }
optIfOChGroupSinkCurrentLowAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest aggregated optical power of all the DWDM input
channels in the OChGroup during the current 15-minute interval."
::= { optIfOChGroupSinkCurrentEntry 3 }
optIfOChGroupSinkCurrentHighAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest aggregated optical power of all the DWDM input
channels in the OChGroup during the current 15-minute interval."
::= { optIfOChGroupSinkCurrentEntry 4 }
optIfOChGroupSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The lower limit threshold on aggregated input power. If
optIfOChGroupSinkCurrentAggregatedInputPower drops to this value
or below, a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOChGroupSinkCurrentEntry 5 }
optIfOChGroupSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upper limit threshold on aggregated input power. If
optIfOChGroupSinkCurrentAggregatedInputPower reaches or exceeds
this value, a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOChGroupSinkCurrentEntry 6 }
optIfOChGroupSinkCurrentOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The optical power monitored at the output
in the OChGroup."
::= { optIfOChGroupSinkCurrentEntry 7 }
optIfOChGroupSinkCurrentLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output
in the OChGroup during the current 15-minute interval."
::= { optIfOChGroupSinkCurrentEntry 8 }
optIfOChGroupSinkCurrentHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output
in the OChGroup during the current 15-minute interval."
::= { optIfOChGroupSinkCurrentEntry 9 }
optIfOChGroupSinkCurrentLowerOutputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The lower limit threshold on the output power. If
optIfOChGroupSinkCurrentOutputPower drops to this value
or below, a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOChGroupSinkCurrentEntry 10 }
optIfOChGroupSinkCurrentUpperOutputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upper limit threshold on the output power. If
optIfOChGroupSinkCurrentOutputPower reaches or exceeds
this value, a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOChGroupSinkCurrentEntry 11 }
-- OChGroup sink interval table
-- Contains data for previous 15-minute performance monitoring
-- intervals.
optIfOChGroupSinkIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOChGroupSinkIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of historical OChGroup sink performance monitoring
information."
::= { optIfOChGroup 3 }
optIfOChGroupSinkIntervalEntry OBJECT-TYPE
SYNTAX OptIfOChGroupSinkIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OChGroup sink performance
monitoring information of an interface during a particular
historical interval."
INDEX { ifIndex, optIfOChGroupSinkIntervalNumber }
::= { optIfOChGroupSinkIntervalTable 1 }
OptIfOChGroupSinkIntervalEntry ::=
SEQUENCE {
optIfOChGroupSinkIntervalNumber OptIfIntervalNumber,
optIfOChGroupSinkIntervalSuspectedFlag TruthValue,
optIfOChGroupSinkIntervalLastAggregatedInputPower Integer32,
optIfOChGroupSinkIntervalLowAggregatedInputPower Integer32,
optIfOChGroupSinkIntervalHighAggregatedInputPower Integer32,
optIfOChGroupSinkIntervalLastOutputPower Integer32,
optIfOChGroupSinkIntervalLowOutputPower Integer32,
optIfOChGroupSinkIntervalHighOutputPower Integer32
}
optIfOChGroupSinkIntervalNumber OBJECT-TYPE
SYNTAX OptIfIntervalNumber
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies the interval."
::= { optIfOChGroupSinkIntervalEntry 1 }
optIfOChGroupSinkIntervalSuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOChGroupSinkIntervalEntry 2 }
optIfOChGroupSinkIntervalLastAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last aggregated optical power of all the DWDM input
channels in the OChGroup during the interval."
::= { optIfOChGroupSinkIntervalEntry 3 }
optIfOChGroupSinkIntervalLowAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest aggregated optical power of all the DWDM input
channels in the OChGroup during the interval."
::= { optIfOChGroupSinkIntervalEntry 4 }
optIfOChGroupSinkIntervalHighAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest aggregated optical power of all the DWDM input
channels in the OChGroup during the interval."
::= { optIfOChGroupSinkIntervalEntry 5 }
optIfOChGroupSinkIntervalLastOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power monitored at the output
in the OChGroup during the interval."
::= { optIfOChGroupSinkIntervalEntry 6 }
optIfOChGroupSinkIntervalLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output
in the OChGroup during the interval."
::= { optIfOChGroupSinkIntervalEntry 7 }
optIfOChGroupSinkIntervalHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output
in the OChGroup during the interval."
::= { optIfOChGroupSinkIntervalEntry 8 }
-- OChGroup sink current day table
-- Contains data for the current 24-hour performance
-- monitoring interval.
optIfOChGroupSinkCurDayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOChGroupSinkCurDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OChGroup sink performance monitoring information for
the current 24-hour interval."
::= { optIfOChGroup 4 }
optIfOChGroupSinkCurDayEntry OBJECT-TYPE
SYNTAX OptIfOChGroupSinkCurDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OChGroup sink performance
monitoring information of an interface for the current
24-hour interval."
INDEX { ifIndex }
::= { optIfOChGroupSinkCurDayTable 1 }
OptIfOChGroupSinkCurDayEntry ::=
SEQUENCE {
optIfOChGroupSinkCurDaySuspectedFlag TruthValue,
optIfOChGroupSinkCurDayLowAggregatedInputPower Integer32,
optIfOChGroupSinkCurDayHighAggregatedInputPower Integer32,
optIfOChGroupSinkCurDayLowOutputPower Integer32,
optIfOChGroupSinkCurDayHighOutputPower Integer32
}
optIfOChGroupSinkCurDaySuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOChGroupSinkCurDayEntry 1 }
optIfOChGroupSinkCurDayLowAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest aggregated optical power of all the DWDM input
channels in the OChGroup during the current 24-hour interval."
::= { optIfOChGroupSinkCurDayEntry 2 }
optIfOChGroupSinkCurDayHighAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest aggregated optical power of all the DWDM input
channels in the OChGroup during the current 24-hour interval."
::= { optIfOChGroupSinkCurDayEntry 3 }
optIfOChGroupSinkCurDayLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output
in the OChGroup during the current 24-hour interval."
::= { optIfOChGroupSinkCurDayEntry 4 }
optIfOChGroupSinkCurDayHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output
in the OChGroup during the current 24-hour interval."
::= { optIfOChGroupSinkCurDayEntry 5 }
-- OChGroup sink previous day table
-- Contains data for the previous 24-hour performance
-- monitoring interval.
optIfOChGroupSinkPrevDayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOChGroupSinkPrevDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OChGroup sink performance monitoring information for
the previous 24-hour interval."
::= { optIfOChGroup 5 }
optIfOChGroupSinkPrevDayEntry OBJECT-TYPE
SYNTAX OptIfOChGroupSinkPrevDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OChGroup sink performance
monitoring information of an interface for the previous
24-hour interval."
INDEX { ifIndex }
::= { optIfOChGroupSinkPrevDayTable 1 }
OptIfOChGroupSinkPrevDayEntry ::=
SEQUENCE {
optIfOChGroupSinkPrevDaySuspectedFlag TruthValue,
optIfOChGroupSinkPrevDayLastAggregatedInputPower Integer32,
optIfOChGroupSinkPrevDayLowAggregatedInputPower Integer32,
optIfOChGroupSinkPrevDayHighAggregatedInputPower Integer32,
optIfOChGroupSinkPrevDayLastOutputPower Integer32,
optIfOChGroupSinkPrevDayLowOutputPower Integer32,
optIfOChGroupSinkPrevDayHighOutputPower Integer32
}
optIfOChGroupSinkPrevDaySuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOChGroupSinkPrevDayEntry 1 }
optIfOChGroupSinkPrevDayLastAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last aggregated optical power of all the DWDM input
channels in the OChGroup during the previous 24-hour interval."
::= { optIfOChGroupSinkPrevDayEntry 2 }
optIfOChGroupSinkPrevDayLowAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest aggregated optical power of all the DWDM input
channels in the OChGroup during the previous 24-hour interval."
::= { optIfOChGroupSinkPrevDayEntry 3 }
optIfOChGroupSinkPrevDayHighAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest aggregated optical power of all the DWDM input
channels in the OChGroup during the previous 24-hour interval."
::= { optIfOChGroupSinkPrevDayEntry 4 }
optIfOChGroupSinkPrevDayLastOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power monitored at the output
in the OChGroup during the previous 24-hour interval."
::= { optIfOChGroupSinkPrevDayEntry 5 }
optIfOChGroupSinkPrevDayLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output
in the OChGroup during the previous 24-hour interval."
::= { optIfOChGroupSinkPrevDayEntry 6 }
optIfOChGroupSinkPrevDayHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output
in the OChGroup during the previous 24-hour interval."
::= { optIfOChGroupSinkPrevDayEntry 7 }
-- OChGroup source current table
-- Contains data for the current 15-minute performance monitoring
-- interval.
optIfOChGroupSrcCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOChGroupSrcCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OChGroup source performance monitoring information for
the current 15-minute interval."
::= { optIfOChGroup 6 }
optIfOChGroupSrcCurrentEntry OBJECT-TYPE
SYNTAX OptIfOChGroupSrcCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OChGroup source performance
monitoring information of an interface for the current
15-minute interval."
INDEX { ifIndex }
::= { optIfOChGroupSrcCurrentTable 1 }
OptIfOChGroupSrcCurrentEntry ::=
SEQUENCE {
optIfOChGroupSrcCurrentSuspectedFlag TruthValue,
optIfOChGroupSrcCurrentOutputPower Integer32,
optIfOChGroupSrcCurrentLowOutputPower Integer32,
optIfOChGroupSrcCurrentHighOutputPower Integer32,
optIfOChGroupSrcCurrentLowerOutputPowerThreshold Integer32,
optIfOChGroupSrcCurrentUpperOutputPowerThreshold Integer32,
optIfOChGroupSrcCurrentAggregatedInputPower Integer32,
optIfOChGroupSrcCurrentLowAggregatedInputPower Integer32,
optIfOChGroupSrcCurrentHighAggregatedInputPower Integer32,
optIfOChGroupSrcCurrentLowerInputPowerThreshold Integer32,
optIfOChGroupSrcCurrentUpperInputPowerThreshold Integer32
}
optIfOChGroupSrcCurrentSuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOChGroupSrcCurrentEntry 1 }
optIfOChGroupSrcCurrentOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The optical power monitored at the output."
::= { optIfOChGroupSrcCurrentEntry 2 }
optIfOChGroupSrcCurrentLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
current 15-minute interval."
::= { optIfOChGroupSrcCurrentEntry 3 }
optIfOChGroupSrcCurrentHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
current 15-minute interval."
::= { optIfOChGroupSrcCurrentEntry 4 }
optIfOChGroupSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The lower limit threshold on output power. If
optIfOChGroupSrcCurrentOutputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOChGroupSrcCurrentEntry 5 }
optIfOChGroupSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upper limit threshold on output power. If
optIfOChGroupSrcCurrentOutputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOChGroupSrcCurrentEntry 6 }
optIfOChGroupSrcCurrentAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The aggregated optical power monitored at the input."
::= { optIfOChGroupSrcCurrentEntry 7 }
optIfOChGroupSrcCurrentLowAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest aggregated optical power monitored at the input
during the current 15-minute interval."
::= { optIfOChGroupSrcCurrentEntry 8 }
optIfOChGroupSrcCurrentHighAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest aggregated optical power monitored at the input
during the current 15-minute interval."
::= { optIfOChGroupSrcCurrentEntry 9 }
optIfOChGroupSrcCurrentLowerInputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The lower limit threshold on input power. If
optIfOChGroupSrcCurrentAggregatedInputPower drops to this value
or below, a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOChGroupSrcCurrentEntry 10 }
optIfOChGroupSrcCurrentUpperInputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upper limit threshold on input power. If
optIfOChGroupSrcCurrentAggregatedInputPower reaches or exceeds
this value, a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOChGroupSrcCurrentEntry 11 }
-- OChGroup source interval table
-- Contains data for previous 15-minute performance monitoring
-- intervals.
optIfOChGroupSrcIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOChGroupSrcIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of historical OChGroup source performance monitoring
information."
::= { optIfOChGroup 7 }
optIfOChGroupSrcIntervalEntry OBJECT-TYPE
SYNTAX OptIfOChGroupSrcIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OChGroup source performance
monitoring information of an interface during a particular
historical interval."
INDEX { ifIndex, optIfOChGroupSrcIntervalNumber }
::= { optIfOChGroupSrcIntervalTable 1 }
OptIfOChGroupSrcIntervalEntry ::=
SEQUENCE {
optIfOChGroupSrcIntervalNumber OptIfIntervalNumber,
optIfOChGroupSrcIntervalSuspectedFlag TruthValue,
optIfOChGroupSrcIntervalLastOutputPower Integer32,
optIfOChGroupSrcIntervalLowOutputPower Integer32,
optIfOChGroupSrcIntervalHighOutputPower Integer32,
optIfOChGroupSrcIntervalLastAggregatedInputPower Integer32,
optIfOChGroupSrcIntervalLowAggregatedInputPower Integer32,
optIfOChGroupSrcIntervalHighAggregatedInputPower Integer32
}
optIfOChGroupSrcIntervalNumber OBJECT-TYPE
SYNTAX OptIfIntervalNumber
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies the interval."
::= { optIfOChGroupSrcIntervalEntry 1 }
optIfOChGroupSrcIntervalSuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOChGroupSrcIntervalEntry 2 }
optIfOChGroupSrcIntervalLastOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power monitored at the output during the
interval."
::= { optIfOChGroupSrcIntervalEntry 3 }
optIfOChGroupSrcIntervalLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
interval."
::= { optIfOChGroupSrcIntervalEntry 4 }
optIfOChGroupSrcIntervalHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
interval."
::= { optIfOChGroupSrcIntervalEntry 5 }
optIfOChGroupSrcIntervalLastAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last aggregated optical power monitored at the input
during the interval."
::= { optIfOChGroupSrcIntervalEntry 6 }
optIfOChGroupSrcIntervalLowAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest aggregated optical power monitored at the input
during the interval."
::= { optIfOChGroupSrcIntervalEntry 7 }
optIfOChGroupSrcIntervalHighAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest aggregated optical power monitored at the input
during the interval."
::= { optIfOChGroupSrcIntervalEntry 8 }
-- OChGroup source current day table
-- Contains data for the current 24-hour performance
-- monitoring interval.
optIfOChGroupSrcCurDayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOChGroupSrcCurDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OChGroup source performance monitoring information for
the current 24-hour interval."
::= { optIfOChGroup 8 }
optIfOChGroupSrcCurDayEntry OBJECT-TYPE
SYNTAX OptIfOChGroupSrcCurDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OChGroup source performance
monitoring information of an interface for the current
24-hour interval."
INDEX { ifIndex }
::= { optIfOChGroupSrcCurDayTable 1 }
OptIfOChGroupSrcCurDayEntry ::=
SEQUENCE {
optIfOChGroupSrcCurDaySuspectedFlag TruthValue,
optIfOChGroupSrcCurDayLowOutputPower Integer32,
optIfOChGroupSrcCurDayHighOutputPower Integer32,
optIfOChGroupSrcCurDayLowAggregatedInputPower Integer32,
optIfOChGroupSrcCurDayHighAggregatedInputPower Integer32
}
optIfOChGroupSrcCurDaySuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOChGroupSrcCurDayEntry 1 }
optIfOChGroupSrcCurDayLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
current 24-hour interval."
::= { optIfOChGroupSrcCurDayEntry 2 }
optIfOChGroupSrcCurDayHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
current 24-hour interval."
::= { optIfOChGroupSrcCurDayEntry 3 }
optIfOChGroupSrcCurDayLowAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest aggregated optical power monitored at the input
during the current 24-hour interval."
::= { optIfOChGroupSrcCurDayEntry 4 }
optIfOChGroupSrcCurDayHighAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest aggregated optical power monitored at the input
during the current 24-hour interval."
::= { optIfOChGroupSrcCurDayEntry 5 }
-- OChGroup source previous day table
-- Contains data for the previous 24-hour performance
-- monitoring interval.
optIfOChGroupSrcPrevDayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOChGroupSrcPrevDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OChGroup source performance monitoring information for
the previous 24-hour interval."
::= { optIfOChGroup 9 }
optIfOChGroupSrcPrevDayEntry OBJECT-TYPE
SYNTAX OptIfOChGroupSrcPrevDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OChGroup source performance
monitoring information of an interface for the previous
24-hour interval."
INDEX { ifIndex }
::= { optIfOChGroupSrcPrevDayTable 1 }
OptIfOChGroupSrcPrevDayEntry ::=
SEQUENCE {
optIfOChGroupSrcPrevDaySuspectedFlag TruthValue,
optIfOChGroupSrcPrevDayLastOutputPower Integer32,
optIfOChGroupSrcPrevDayLowOutputPower Integer32,
optIfOChGroupSrcPrevDayHighOutputPower Integer32,
optIfOChGroupSrcPrevDayLastAggregatedInputPower Integer32,
optIfOChGroupSrcPrevDayLowAggregatedInputPower Integer32,
optIfOChGroupSrcPrevDayHighAggregatedInputPower Integer32
}
optIfOChGroupSrcPrevDaySuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOChGroupSrcPrevDayEntry 1 }
optIfOChGroupSrcPrevDayLastOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power monitored at the output during the
previous 24-hour interval."
::= { optIfOChGroupSrcPrevDayEntry 2 }
optIfOChGroupSrcPrevDayLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
previous 24-hour interval."
::= { optIfOChGroupSrcPrevDayEntry 3 }
optIfOChGroupSrcPrevDayHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
previous 24-hour interval."
::= { optIfOChGroupSrcPrevDayEntry 4 }
optIfOChGroupSrcPrevDayLastAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last aggregated optical power monitored at the input
during the previous 24-hour interval."
::= { optIfOChGroupSrcPrevDayEntry 5 }
optIfOChGroupSrcPrevDayLowAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest aggregated optical power monitored at the input
during the previous 24-hour interval."
::= { optIfOChGroupSrcPrevDayEntry 6 }
optIfOChGroupSrcPrevDayHighAggregatedInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest aggregated optical power monitored at the input
during the previous 24-hour interval."
::= { optIfOChGroupSrcPrevDayEntry 7 }
-- the optIfOCh group
-- This group handles the configuration and
-- performance monitoring information for OCh layers.
-- OCh config table
optIfOChConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOChConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OCh configuration information."
::= { optIfOCh 1 }
optIfOChConfigEntry OBJECT-TYPE
SYNTAX OptIfOChConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OCh configuration
information of an interface."
INDEX { ifIndex }
::= { optIfOChConfigTable 1 }
OptIfOChConfigEntry ::=
SEQUENCE {
optIfOChDirectionality OptIfDirectionality,
optIfOChCurrentStatus BITS
}
optIfOChDirectionality OBJECT-TYPE
SYNTAX OptIfDirectionality
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the directionality of the entity."
::= { optIfOChConfigEntry 1 }
optIfOChCurrentStatus OBJECT-TYPE
SYNTAX BITS {
losP(0),
los(1),
oci(2),
ssfP(3),
ssfO(4),
ssf(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the defect condition of the entity, if any.
This object is applicable when optIfOChDirectionality
has the value sink(1) or bidirectional(3).
In full-capability systems the bit position los(1) is not used.
In reduced-capability systems or at IrDI interfaces only
the bit positions los(1) and ssfP(3) are used."
::= { optIfOChConfigEntry 2 }
-- OCh sink current table
-- Contains data for the current 15-minute performance monitoring
-- interval.
optIfOChSinkCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOChSinkCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OCh sink performance monitoring information for
the current 15-minute interval."
::= { optIfOCh 2 }
optIfOChSinkCurrentEntry OBJECT-TYPE
SYNTAX OptIfOChSinkCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OCh sink performance
monitoring information for an interface for the current
15-minute interval."
INDEX { ifIndex }
::= { optIfOChSinkCurrentTable 1 }
OptIfOChSinkCurrentEntry ::=
SEQUENCE {
optIfOChSinkCurrentSuspectedFlag TruthValue,
optIfOChSinkCurrentInputPower Integer32,
optIfOChSinkCurrentLowInputPower Integer32,
optIfOChSinkCurrentHighInputPower Integer32,
optIfOChSinkCurrentLowerInputPowerThreshold Integer32,
optIfOChSinkCurrentUpperInputPowerThreshold Integer32
}
optIfOChSinkCurrentSuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOChSinkCurrentEntry 1 }
optIfOChSinkCurrentInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The optical power monitored at the input."
::= { optIfOChSinkCurrentEntry 2 }
optIfOChSinkCurrentLowInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the input during the
current 15-minute interval."
::= { optIfOChSinkCurrentEntry 3 }
optIfOChSinkCurrentHighInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the input during the
current 15-minute interval."
::= { optIfOChSinkCurrentEntry 4 }
optIfOChSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The lower limit threshold on input power. If
optIfOChSinkCurrentInputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOChSinkCurrentEntry 5 }
optIfOChSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upper limit threshold on input power. If
optIfOChSinkCurrentInputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOChSinkCurrentEntry 6 }
-- OCh sink interval table
-- Contains data for previous 15-minute performance monitoring
-- intervals.
optIfOChSinkIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOChSinkIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of historical OCh sink performance monitoring
information."
::= { optIfOCh 3 }
optIfOChSinkIntervalEntry OBJECT-TYPE
SYNTAX OptIfOChSinkIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OCh sink performance
monitoring information of an interface during a particular
historical interval."
INDEX { ifIndex, optIfOChSinkIntervalNumber }
::= { optIfOChSinkIntervalTable 1 }
OptIfOChSinkIntervalEntry ::=
SEQUENCE {
optIfOChSinkIntervalNumber OptIfIntervalNumber,
optIfOChSinkIntervalSuspectedFlag TruthValue,
optIfOChSinkIntervalLastInputPower Integer32,
optIfOChSinkIntervalLowInputPower Integer32,
optIfOChSinkIntervalHighInputPower Integer32
}
optIfOChSinkIntervalNumber OBJECT-TYPE
SYNTAX OptIfIntervalNumber
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies the interval."
::= { optIfOChSinkIntervalEntry 1 }
optIfOChSinkIntervalSuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOChSinkIntervalEntry 2 }
optIfOChSinkIntervalLastInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power monitored at the input during the
interval."
::= { optIfOChSinkIntervalEntry 3 }
optIfOChSinkIntervalLowInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the input during the
interval."
::= { optIfOChSinkIntervalEntry 4 }
optIfOChSinkIntervalHighInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the input during the
interval."
::= { optIfOChSinkIntervalEntry 5 }
-- OCh sink current day table
-- Contains data for the current 24-hour performance
-- monitoring interval.
optIfOChSinkCurDayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOChSinkCurDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OCh sink performance monitoring information for
the current 24-hour interval."
::= { optIfOCh 4 }
optIfOChSinkCurDayEntry OBJECT-TYPE
SYNTAX OptIfOChSinkCurDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OCh sink performance
monitoring information of an interface for the current
24-hour interval."
INDEX { ifIndex }
::= { optIfOChSinkCurDayTable 1 }
OptIfOChSinkCurDayEntry ::=
SEQUENCE {
optIfOChSinkCurDaySuspectedFlag TruthValue,
optIfOChSinkCurDayLowInputPower Integer32,
optIfOChSinkCurDayHighInputPower Integer32
}
optIfOChSinkCurDaySuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOChSinkCurDayEntry 1 }
optIfOChSinkCurDayLowInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the input during the
current 24-hour interval."
::= { optIfOChSinkCurDayEntry 2 }
optIfOChSinkCurDayHighInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the input during the
current 24-hour interval."
::= { optIfOChSinkCurDayEntry 3 }
-- OCh sink previous day table
-- Contains data for the previous 24-hour performance
-- monitoring interval.
optIfOChSinkPrevDayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOChSinkPrevDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OCh sink performance monitoring information for
the previous 24-hour interval."
::= { optIfOCh 5 }
optIfOChSinkPrevDayEntry OBJECT-TYPE
SYNTAX OptIfOChSinkPrevDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OCh sink performance
monitoring information of an interface for the previous
24-hour interval."
INDEX { ifIndex }
::= { optIfOChSinkPrevDayTable 1 }
OptIfOChSinkPrevDayEntry ::=
SEQUENCE {
optIfOChSinkPrevDaySuspectedFlag TruthValue,
optIfOChSinkPrevDayLastInputPower Integer32,
optIfOChSinkPrevDayLowInputPower Integer32,
optIfOChSinkPrevDayHighInputPower Integer32
}
optIfOChSinkPrevDaySuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOChSinkPrevDayEntry 1 }
optIfOChSinkPrevDayLastInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power monitored at the input during the
previous 24-hour interval."
::= { optIfOChSinkPrevDayEntry 2 }
optIfOChSinkPrevDayLowInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the input during the
previous 24-hour interval."
::= { optIfOChSinkPrevDayEntry 3 }
optIfOChSinkPrevDayHighInputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the input during the
previous 24-hour interval."
::= { optIfOChSinkPrevDayEntry 4 }
-- OCh source current table
-- Contains data for the current 15-minute performance monitoring
-- interval.
optIfOChSrcCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOChSrcCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OCh source performance monitoring information for
the current 15-minute interval."
::= { optIfOCh 6 }
optIfOChSrcCurrentEntry OBJECT-TYPE
SYNTAX OptIfOChSrcCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OCh source performance
monitoring information of an interface for the current
15-minute interval."
INDEX { ifIndex }
::= { optIfOChSrcCurrentTable 1 }
OptIfOChSrcCurrentEntry ::=
SEQUENCE {
optIfOChSrcCurrentSuspectedFlag TruthValue,
optIfOChSrcCurrentOutputPower Integer32,
optIfOChSrcCurrentLowOutputPower Integer32,
optIfOChSrcCurrentHighOutputPower Integer32,
optIfOChSrcCurrentLowerOutputPowerThreshold Integer32,
optIfOChSrcCurrentUpperOutputPowerThreshold Integer32
}
optIfOChSrcCurrentSuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOChSrcCurrentEntry 1 }
optIfOChSrcCurrentOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The optical power monitored at the output."
::= { optIfOChSrcCurrentEntry 2 }
optIfOChSrcCurrentLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
current 15-minute interval."
::= { optIfOChSrcCurrentEntry 3 }
optIfOChSrcCurrentHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
current 15-minute interval."
::= { optIfOChSrcCurrentEntry 4 }
optIfOChSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The lower limit threshold on output power. If
optIfOChSrcCurrentOutputPower drops to this value or below,
a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOChSrcCurrentEntry 5 }
optIfOChSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The upper limit threshold on output power. If
optIfOChSrcCurrentOutputPower reaches or exceeds this value,
a Threshold Crossing Alert (TCA) should be sent."
::= { optIfOChSrcCurrentEntry 6 }
-- OCh source interval table
-- Contains data for previous 15-minute performance monitoring
-- intervals.
optIfOChSrcIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOChSrcIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of historical OCh source performance monitoring
information."
::= { optIfOCh 7 }
optIfOChSrcIntervalEntry OBJECT-TYPE
SYNTAX OptIfOChSrcIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OCh source performance
monitoring information of an interface during a particular
historical interval."
INDEX { ifIndex, optIfOChSrcIntervalNumber }
::= { optIfOChSrcIntervalTable 1 }
OptIfOChSrcIntervalEntry ::=
SEQUENCE {
optIfOChSrcIntervalNumber OptIfIntervalNumber,
optIfOChSrcIntervalSuspectedFlag TruthValue,
optIfOChSrcIntervalLastOutputPower Integer32,
optIfOChSrcIntervalLowOutputPower Integer32,
optIfOChSrcIntervalHighOutputPower Integer32
}
optIfOChSrcIntervalNumber OBJECT-TYPE
SYNTAX OptIfIntervalNumber
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies the interval."
::= { optIfOChSrcIntervalEntry 1 }
optIfOChSrcIntervalSuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOChSrcIntervalEntry 2 }
optIfOChSrcIntervalLastOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power monitored at the output during the
interval."
::= { optIfOChSrcIntervalEntry 3 }
optIfOChSrcIntervalLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
interval."
::= { optIfOChSrcIntervalEntry 4 }
optIfOChSrcIntervalHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
interval."
::= { optIfOChSrcIntervalEntry 5 }
-- OCh source current day table
-- Contains data for the current 24-hour performance
-- monitoring interval.
optIfOChSrcCurDayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOChSrcCurDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OCh source performance monitoring information for
the current 24-hour interval."
::= { optIfOCh 8 }
optIfOChSrcCurDayEntry OBJECT-TYPE
SYNTAX OptIfOChSrcCurDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OCh source performance
monitoring information of an interface for the current
24-hour interval."
INDEX { ifIndex }
::= { optIfOChSrcCurDayTable 1 }
OptIfOChSrcCurDayEntry ::=
SEQUENCE {
optIfOChSrcCurDaySuspectedFlag TruthValue,
optIfOChSrcCurDayLowOutputPower Integer32,
optIfOChSrcCurDayHighOutputPower Integer32
}
optIfOChSrcCurDaySuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOChSrcCurDayEntry 1 }
optIfOChSrcCurDayLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
current 24-hour interval."
::= { optIfOChSrcCurDayEntry 2 }
optIfOChSrcCurDayHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
current 24-hour interval."
::= { optIfOChSrcCurDayEntry 3 }
-- OCh source previous day table
-- Contains data for the previous 24-hour performance
-- monitoring interval.
optIfOChSrcPrevDayTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOChSrcPrevDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OCh source performance monitoring information for
the previous 24-hour interval."
::= { optIfOCh 9 }
optIfOChSrcPrevDayEntry OBJECT-TYPE
SYNTAX OptIfOChSrcPrevDayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OCh source performance
monitoring information of an interface for the previous
24-hour interval."
INDEX { ifIndex }
::= { optIfOChSrcPrevDayTable 1 }
OptIfOChSrcPrevDayEntry ::=
SEQUENCE {
optIfOChSrcPrevDaySuspectedFlag TruthValue,
optIfOChSrcPrevDayLastOutputPower Integer32,
optIfOChSrcPrevDayLowOutputPower Integer32,
optIfOChSrcPrevDayHighOutputPower Integer32
}
optIfOChSrcPrevDaySuspectedFlag OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, the data in this entry may be unreliable."
::= { optIfOChSrcPrevDayEntry 1 }
optIfOChSrcPrevDayLastOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last optical power monitored at the output during the
previous 24-hour interval."
::= { optIfOChSrcPrevDayEntry 2 }
optIfOChSrcPrevDayLowOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest optical power monitored at the output during the
previous 24-hour interval."
::= { optIfOChSrcPrevDayEntry 3 }
optIfOChSrcPrevDayHighOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dbm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest optical power monitored at the output during the
previous 24-hour interval."
::= { optIfOChSrcPrevDayEntry 4 }
-- the optIfOTUk group
-- This group handles the configuration
-- information for OTUk layers.
-- OTUk config table
optIfOTUkConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfOTUkConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of OTUk configuration information."
::= { optIfOTUk 1 }
optIfOTUkConfigEntry OBJECT-TYPE
SYNTAX OptIfOTUkConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains OTUk configuration
information of an interface."
INDEX { ifIndex }
::= { optIfOTUkConfigTable 1 }
OptIfOTUkConfigEntry ::=
SEQUENCE {
optIfOTUkDirectionality OptIfDirectionality,
optIfOTUkBitRateK OptIfBitRateK,
optIfOTUkTraceIdentifierTransmitted OptIfTxTI,
optIfOTUkDAPIExpected OptIfExDAPI,
optIfOTUkSAPIExpected OptIfExSAPI,
optIfOTUkTraceIdentifierAccepted OptIfAcTI,
optIfOTUkTIMDetMode OptIfTIMDetMode,
optIfOTUkTIMActEnabled TruthValue,
optIfOTUkDEGThr OptIfDEGThr,
optIfOTUkDEGM OptIfDEGM,
optIfOTUkSinkAdaptActive TruthValue,
optIfOTUkSourceAdaptActive TruthValue,
optIfOTUkSinkFECEnabled TruthValue,
optIfOTUkCurrentStatus BITS
}
optIfOTUkDirectionality OBJECT-TYPE
SYNTAX OptIfDirectionality
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the directionality of the entity."
::= { optIfOTUkConfigEntry 1 }
optIfOTUkBitRateK OBJECT-TYPE
SYNTAX OptIfBitRateK
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the bit rate of the entity."
::= { optIfOTUkConfigEntry 2 }
optIfOTUkTraceIdentifierTransmitted OBJECT-TYPE
SYNTAX OptIfTxTI
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The trace identifier transmitted.
This object is applicable when optIfOTUkDirectionality
has the value source(2) or bidirectional(3). It must not
be instantiated in rows where optIfOTUkDirectionality
has the value sink(1).
If no value is ever set by a management entity for this
object, system-specific default value will be used.
Any implementation that instantiates this object must
document the system-specific default value or how it
is derived."
::= { optIfOTUkConfigEntry 3 }
optIfOTUkDAPIExpected OBJECT-TYPE
SYNTAX OptIfExDAPI
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DAPI expected by the receiver.
This object is only applicable to the sink function, i.e.,
only when optIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfOTUkDirectionality has the value source(2).
This object has no effect when optIfOTUkTIMDetMode has
the value off(1)."
::= { optIfOTUkConfigEntry 4 }
optIfOTUkSAPIExpected OBJECT-TYPE
SYNTAX OptIfExSAPI
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SAPI expected by the receiver.
This object is only applicable to the sink function, i.e.,
only when optIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfOTUkDirectionality has the value source(2).
This object has no effect when optIfOTUkTIMDetMode has
the value off(1)."
::= { optIfOTUkConfigEntry 5 }
optIfOTUkTraceIdentifierAccepted OBJECT-TYPE
SYNTAX OptIfAcTI
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual trace identifier accepted.
This object is only applicable to the sink function, i.e.,
only when optIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfOTUkDirectionality has the value source(2).
The value of this object is unspecified when
optIfOTUkCurrentStatus indicates a near-end defect
(i.e., ssf(3), lof(4), ais(5), lom(6)) that prevents
extraction of the trace message."
::= { optIfOTUkConfigEntry 6 }
optIfOTUkTIMDetMode OBJECT-TYPE
SYNTAX OptIfTIMDetMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the mode of the Trace Identifier Mismatch (TIM)
Detection function.
This object is only applicable to the sink function, i.e.,
only when optIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfOTUkDirectionality has the value source(2).
The default value of this object is off(1)."
::= { optIfOTUkConfigEntry 7 }
optIfOTUkTIMActEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the Trace Identifier Mismatch (TIM)
Consequent Action function is enabled.
This object is only applicable to the sink function, i.e.,
only when optIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfOTUkDirectionality has the value source(2).
This object has no effect when optIfOTUkTIMDetMode has
the value off(1).
The default value of this object is false(2)."
::= { optIfOTUkConfigEntry 8 }
optIfOTUkDEGThr OBJECT-TYPE
SYNTAX OptIfDEGThr
UNITS "percentage"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the threshold level for declaring a performance
monitoring (PM) Second to be bad. A PM Second is declared bad if
the percentage of detected errored blocks in that second is
greater than or equal to optIfOTUkDEGThr.
This object is only applicable to the sink function, i.e.,
only when optIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfOTUkDirectionality has the value source(2).
The default value of this object is Severely Errored Second
(SES) Estimator (See ITU-T G.7710)."
::= { optIfOTUkConfigEntry 9 }
optIfOTUkDEGM OBJECT-TYPE
SYNTAX OptIfDEGM
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the threshold level for declaring a Degraded Signal
defect (dDEG). A dDEG shall be declared if optIfOTUkDEGM
consecutive bad PM Seconds are detected.
This object is only applicable to the sink function, i.e.,
only when optIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfOTUkDirectionality has the value source(2).
The default value of this object is 7 (See ITU-T G.7710)."
::= { optIfOTUkConfigEntry 10 }
optIfOTUkSinkAdaptActive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the sink adaptation function is activated or
not.
This object is only applicable to the sink function, i.e.,
only when optIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfOTUkDirectionality has the value source(2).
The default value of this object is false(2)."
::= { optIfOTUkConfigEntry 11 }
optIfOTUkSourceAdaptActive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the source adaptation function is activated or
not.
This object is only applicable to the source function, i.e.,
only when optIfOTUkDirectionality has the value source(2)
or bidirectional(3). It must not be instantiated in rows
where optIfOTUkDirectionality has the value sink(1).
The default value of this object is false(2)."
::= { optIfOTUkConfigEntry 12 }
optIfOTUkSinkFECEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If Forward Error Correction (FEC) is supported, this object
indicates whether FEC at the OTUk sink adaptation function is
enabled or not.
This object is only applicable to the sink function, i.e.,
only when optIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfOTUkDirectionality has the value source(2).
The default value of this object is true(1)."
::= { optIfOTUkConfigEntry 13 }
optIfOTUkCurrentStatus OBJECT-TYPE
SYNTAX BITS {
tim(0),
deg(1),
bdi(2),
ssf(3),
lof(4),
ais(5),
lom(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the defect condition of the entity, if any.
This object is only applicable to the sink function, i.e.,
only when optIfOTUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfOTUkDirectionality has the value source(2)."
::= { optIfOTUkConfigEntry 14 }
-- GCC0 config table
optIfGCC0ConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfGCC0ConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of GCC0 configuration information."
::= { optIfOTUk 2 }
optIfGCC0ConfigEntry OBJECT-TYPE
SYNTAX OptIfGCC0ConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains GCC0 configuration
information of an interface. Each instance must
correspond to an instance of optIfOTUkConfigEntry.
Separate source and/or sink instances may exist
for a given ifIndex value, or a single bidirectional
instance may exist, but a bidirectional instance may
not coexist with a source or sink instance.
Instances of this conceptual row persist across
agent restarts."
INDEX { ifIndex, optIfGCC0Directionality }
::= { optIfGCC0ConfigTable 1 }
OptIfGCC0ConfigEntry ::=
SEQUENCE {
optIfGCC0Directionality OptIfDirectionality,
optIfGCC0Application SnmpAdminString,
optIfGCC0RowStatus RowStatus
}
optIfGCC0Directionality OBJECT-TYPE
SYNTAX OptIfDirectionality
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the directionality of the entity.
The values source(2) and bidirectional(3) are
not allowed if the corresponding instance of
optIfOTUkDirectionality has the value sink(1).
The values sink(1) and bidirectional(3) are
not allowed if the corresponding instance of
optIfOTUkDirectionality has the value source(2)."
::= { optIfGCC0ConfigEntry 1 }
optIfGCC0Application OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the application transported by the GCC0 entity.
Example applications are ECC, User data channel.
The value of this object may not be changed when
optIfGCC0RowStatus has the value active(1)."
::= { optIfGCC0ConfigEntry 2 }
optIfGCC0RowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This columnar object is used for creating and deleting a
conceptual row of the optIfGCC0 config table.
It is used to model the addGCC0Access and removeGCC0Access
operations of an OTUk_TTP for GCC0 access control as defined
in G.874.1. Setting RowStatus to createAndGo or createAndWait
implies addGCC0Access. Setting RowStatus to destroy implies
removeGCC0Access."
::= { optIfGCC0ConfigEntry 3 }
-- the optIfODUk group
-- This group handles the configuration information
-- for the ODUk layers.
-- ODUk config table
optIfODUkConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfODUkConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of ODUk configuration information."
::= { optIfODUk 1 }
optIfODUkConfigEntry OBJECT-TYPE
SYNTAX OptIfODUkConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains ODUk configuration
information of an interface."
INDEX { ifIndex }
::= { optIfODUkConfigTable 1 }
OptIfODUkConfigEntry ::=
SEQUENCE {
optIfODUkDirectionality OptIfDirectionality,
optIfODUkBitRateK OptIfBitRateK,
optIfODUkTcmFieldsInUse BITS,
optIfODUkPositionSeqCurrentSize Unsigned32,
optIfODUkTtpPresent TruthValue
}
optIfODUkDirectionality OBJECT-TYPE
SYNTAX OptIfDirectionality
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the directionality of the entity."
::= { optIfODUkConfigEntry 1 }
optIfODUkBitRateK OBJECT-TYPE
SYNTAX OptIfBitRateK
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the bit rate of the entity."
::= { optIfODUkConfigEntry 2 }
optIfODUkTcmFieldsInUse OBJECT-TYPE
SYNTAX BITS {
tcmField1(0),
tcmField2(1),
tcmField3(2),
tcmField4(3),
tcmField5(4),
tcmField6(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the TCM field(s) that are currently in use.
The positions of the bits correspond to the TCM fields.
A bit that is set to 1 means that the corresponding TCM
field is used. This object will be updated when rows are
created in or deleted from the optIfODUkTConfigTable, or
the optIfODUkTNimConfigTable."
::= { optIfODUkConfigEntry 3 }
optIfODUkPositionSeqCurrentSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the current size of the position
sequence (i.e., number of TCM function and/or GCC12
access that have been created in the ODUk interface).
When the value of this variable is greater than zero,
it means that one or more TCM function and/or GCC12
access have been created in the ODUk interface. In this
case, there will be as many rows in the
optIfODUkPositionSeqTable as the value of
optIfODUkPositionSeqCurrentSize corresponding to this
ODUk interface, one row for each TCM function or GCC12
access. The position of the TCM function and/or
GCC12 access within the sequence is indicated by the
optIfODUkPositionSeqPosition variable in
optIfODUkPositionSeqTable.
The optIfODUkPositionSeqTable also provides pointers
to the corresponding TCM function (optIfODUkT) and
GCC12 access (optIfGCC12) entities."
::= { optIfODUkConfigEntry 4 }
optIfODUkTtpPresent OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object has the value true(1) if the ifEntry under which
it is instantiated contains an ODUk Trail Termination Point,
i.e., is the endpoint of an ODUk path. In that case there
will be a corresponding row in the ODUk TTP config table and
it will not be possible to create corresponding rows in the
ODUk NIM config table. This object has the value false(2)
if the ifEntry under which it is instantiated contains an
intermediate ODUk Connection Termination Point. In that case
there is no corresponding row in the ODUk TTP config table,
but it will be possible to create corresponding rows in the
ODUk NIM config table. This object also affects the allowable
options in rows created in the GCC12 config table and in the
ODUkT config table, as specified in the DESCRIPTION clauses
of the columns in those tables."
::= { optIfODUkConfigEntry 5 }
-- ODUk Trail Termination Point (TTP) config table
optIfODUkTtpConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfODUkTtpConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of ODUk TTP configuration information."
::= { optIfODUk 2 }
optIfODUkTtpConfigEntry OBJECT-TYPE
SYNTAX OptIfODUkTtpConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains ODUk TTP configuration
information of an interface."
INDEX { ifIndex }
::= { optIfODUkTtpConfigTable 1 }
OptIfODUkTtpConfigEntry ::=
SEQUENCE {
optIfODUkTtpTraceIdentifierTransmitted OptIfTxTI,
optIfODUkTtpDAPIExpected OptIfExDAPI,
optIfODUkTtpSAPIExpected OptIfExSAPI,
optIfODUkTtpTraceIdentifierAccepted OptIfAcTI,
optIfODUkTtpTIMDetMode OptIfTIMDetMode,
optIfODUkTtpTIMActEnabled TruthValue,
optIfODUkTtpDEGThr OptIfDEGThr,
optIfODUkTtpDEGM OptIfDEGM,
optIfODUkTtpCurrentStatus BITS
}
optIfODUkTtpTraceIdentifierTransmitted OBJECT-TYPE
SYNTAX OptIfTxTI
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The trace identifier transmitted.
This object is applicable when optIfODUkDirectionality
has the value source(2) or bidirectional(3). It must not
be instantiated in rows where optIfODUkDirectionality
has the value sink(1).
If no value is ever set by a management entity for this
object, system-specific default value will be used.
Any implementation that instantiates this object must
document the system-specific default value or how it
is derived."
::= { optIfODUkTtpConfigEntry 1 }
optIfODUkTtpDAPIExpected OBJECT-TYPE
SYNTAX OptIfExDAPI
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DAPI expected by the receiver.
This object is only applicable to the sink function, i.e.,
only when optIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfODUkDirectionality has the value source(2).
This object has no effect when optIfODUkTtpTIMDetMode has
the value off(1)."
::= { optIfODUkTtpConfigEntry 2 }
optIfODUkTtpSAPIExpected OBJECT-TYPE
SYNTAX OptIfExSAPI
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SAPI expected by the receiver.
This object is only applicable to the sink function, i.e.,
only when optIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfODUkDirectionality has the value source(2).
This object has no effect when optIfODUkTtpTIMDetMode has
the value off(1)."
::= { optIfODUkTtpConfigEntry 3 }
optIfODUkTtpTraceIdentifierAccepted OBJECT-TYPE
SYNTAX OptIfAcTI
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual trace identifier accepted.
This object is only applicable to the sink function, i.e.,
only when optIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfODUkDirectionality has the value source(2).
The value of this object is unspecified when
optIfODUkTtpCurrentStatus indicates a near-end defect
(i.e., oci(0), lck(1), ssf(5)) that prevents extraction
of the trace message."
::= { optIfODUkTtpConfigEntry 4 }
optIfODUkTtpTIMDetMode OBJECT-TYPE
SYNTAX OptIfTIMDetMode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the mode of the Trace Identifier Mismatch (TIM)
Detection function.
This object is only applicable to the sink function, i.e.,
only when optIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfODUkDirectionality has the value source(2).
The default value of this object is off(1)."
::= { optIfODUkTtpConfigEntry 5 }
optIfODUkTtpTIMActEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the Trace Identifier Mismatch (TIM)
Consequent Action function is enabled.
This object is only applicable to the sink function, i.e.,
only when optIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfODUkDirectionality has the value source(2).
This object has no effect when optIfODUkTtpTIMDetMode has
the value off(1).
The default value of this object is false(2)."
::= { optIfODUkTtpConfigEntry 6 }
optIfODUkTtpDEGThr OBJECT-TYPE
SYNTAX OptIfDEGThr
UNITS "percentage"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the threshold level for declaring a performance
monitoring (PM) Second to be bad. A PM Second is declared bad if
the percentage of detected errored blocks in that second is
greater than or equal to optIfODUkDEGThr.
This object is only applicable to the sink function, i.e.,
only when optIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfODUkDirectionality has the value source(2).
The default value of this object is Severely Errored Second
(SES) Estimator (See ITU-T G.7710)."
::= { optIfODUkTtpConfigEntry 7 }
optIfODUkTtpDEGM OBJECT-TYPE
SYNTAX OptIfDEGM
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the threshold level for declaring a Degraded Signal
defect (dDEG). A dDEG shall be declared if optIfODUkDEGM
consecutive bad PM Seconds are detected.
This object is only applicable to the sink function, i.e.,
only when optIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfODUkDirectionality has the value source(2).
The default value of this object is 7 (See ITU-T G.7710)."
::= { optIfODUkTtpConfigEntry 8 }
optIfODUkTtpCurrentStatus OBJECT-TYPE
SYNTAX BITS {
oci(0),
lck(1),
tim(2),
deg(3),
bdi(4),
ssf(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the defect condition of the entity, if any.
This object is only applicable to the sink function, i.e.,
only when optIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfODUkDirectionality has the value source(2)."
::= { optIfODUkTtpConfigEntry 9 }
-- ODUk Position Sequence table
optIfODUkPositionSeqTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfODUkPositionSeqEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of ODUk Position Sequence information."
::= { optIfODUk 3 }
optIfODUkPositionSeqEntry OBJECT-TYPE
SYNTAX OptIfODUkPositionSeqEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains ODUk position sequence
information of an ODUk interface. The ODUk interface
is identified by the ifIndex. Associated with each
ODUk interface there may be one of more conceptual
rows in the optIfODUkPositionSeqTable. Each row
represents a TCM or GCC12 access function within the
associated ODUk interface. Rows of the
optIfODUkPositionSeqTable table are created/deleted
as the result of the creation/deletion of the optIfODUkT
or optIfGCC12 entities."
INDEX { ifIndex, optIfODUkPositionSeqIndex }
::= { optIfODUkPositionSeqTable 1 }
OptIfODUkPositionSeqEntry ::=
SEQUENCE {
optIfODUkPositionSeqIndex Unsigned32,
optIfODUkPositionSeqPosition Unsigned32,
optIfODUkPositionSeqPointer RowPointer
}
optIfODUkPositionSeqIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This variable identifies a row in the
optIfODUkPositionSeqTable Table.
Each row of the optIfODUkPositionSeqTable Table
represents a TCM or GCC12 access function within the
associated ODUk interface."
::= { optIfODUkPositionSeqEntry 1 }
optIfODUkPositionSeqPosition OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the position of the TCM or
GCC12 access function within the sequence of TCMs &
GCC12 access functions of the associated ODUk
interface. The TCM or GCC12 presented by this row is
referenced by the optIfODUkPositionSeqPointer variable."
::= { optIfODUkPositionSeqEntry 2 }
optIfODUkPositionSeqPointer OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable identifies the TCM or GCC12 access function
by pointing to the corresponding optIfODUkT or optIfGCC12
entity."
::= { optIfODUkPositionSeqEntry 3 }
-- ODUk Non-intrusive monitoring (Nim) config table
optIfODUkNimConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfODUkNimConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of ODUkNim configuration information."
::= { optIfODUk 4 }
optIfODUkNimConfigEntry OBJECT-TYPE
SYNTAX OptIfODUkNimConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains ODUkNim configuration
information of an interface. Each instance must
correspond to an instance of optIfODUkConfigEntry
for which optIfODUkTtpPresent has the value false(2).
Instances of this conceptual row persist across
agent restarts, and read-create columns other
than the status column may be modified while the
row is active."
INDEX { ifIndex, optIfODUkNimDirectionality }
::= { optIfODUkNimConfigTable 1 }
OptIfODUkNimConfigEntry ::=
SEQUENCE {
optIfODUkNimDirectionality OptIfSinkOrSource,
optIfODUkNimDAPIExpected OptIfExDAPI,
optIfODUkNimSAPIExpected OptIfExSAPI,
optIfODUkNimTraceIdentifierAccepted OptIfAcTI,
optIfODUkNimTIMDetMode OptIfTIMDetMode,
optIfODUkNimTIMActEnabled TruthValue,
optIfODUkNimDEGThr OptIfDEGThr,
optIfODUkNimDEGM OptIfDEGM,
optIfODUkNimCurrentStatus BITS,
optIfODUkNimRowStatus RowStatus
}
optIfODUkNimDirectionality OBJECT-TYPE
SYNTAX OptIfSinkOrSource
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specifies the monitor point for the ODUk Path non-intrusive
monitoring function. The value source(2) is not allowed
if the corresponding instance of optIfODUkDirectionality
has the value sink(1), and the value sink(1) is not allowed
if the corresponding instance of optIfODUkDirectionality
has the value source(2). Either the value sink(1) or
source(2) is allowed if the corresponding instance of
optIfODUkDirectionality has the value bidirectional(3).
The value sink(1) means monitoring at the sink direction
path signal of the ODUk CTP.
The value source(2) means monitoring at the source direction
path signal of the ODUk CTP. Monitoring the source direction
of an ODUk CTP is necessary in those cases where the ODUk CTP
is at an SNCP (Subnetwork Connection Protection) end (e.g., see
Figure I.1.2/G.874.1). If one would like to get the performance
of the protected connection, one cannot use the NIM function
at both ODUk CTP sinks (before the matrix), instead one should
monitor the signal at the source ODUk CTP after the matrix."
::= { optIfODUkNimConfigEntry 1 }
optIfODUkNimDAPIExpected OBJECT-TYPE
SYNTAX OptIfExDAPI
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The DAPI expected by the receiver.
This object has no effect if optIfODUkNimTIMDetMode has
the value off(1) or sapi(3)."
::= { optIfODUkNimConfigEntry 2 }
optIfODUkNimSAPIExpected OBJECT-TYPE
SYNTAX OptIfExSAPI
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The SAPI expected by the receiver.
This object has no effect if optIfODUkNimTIMDetMode has
the value off(1) or dapi(2)."
::= { optIfODUkNimConfigEntry 3 }
optIfODUkNimTraceIdentifierAccepted OBJECT-TYPE
SYNTAX OptIfAcTI
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual trace identifier accepted. The value of
this object is unspecified if optIfODUkNimCurrentStatus
has any of the bit positions oci(0), lck(1), or ssf(5)
set or if optIfODUkNimRowStatus has any value other
than active(1)."
::= { optIfODUkNimConfigEntry 4 }
optIfODUkNimTIMDetMode OBJECT-TYPE
SYNTAX OptIfTIMDetMode
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the mode of the Trace Identifier Mismatch (TIM)
Detection function."
::= { optIfODUkNimConfigEntry 5 }
optIfODUkNimTIMActEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether the Trace Identifier Mismatch (TIM)
Consequent Action function is enabled."
::= { optIfODUkNimConfigEntry 6 }
optIfODUkNimDEGThr OBJECT-TYPE
SYNTAX OptIfDEGThr
UNITS "percentage"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the threshold level for declaring a performance
monitoring (PM) Second to be bad. A PM Second is declared bad
if the percentage of detected errored blocks in that second is
greater than or equal to optIfODUkNimDEGThr."
::= { optIfODUkNimConfigEntry 7 }
optIfODUkNimDEGM OBJECT-TYPE
SYNTAX OptIfDEGM
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the threshold level for declaring a Degraded Signal
defect (dDEG). A dDEG shall be declared if optIfODUkNimDEGM
consecutive bad PM Seconds are detected."
::= { optIfODUkNimConfigEntry 8 }
optIfODUkNimCurrentStatus OBJECT-TYPE
SYNTAX BITS {
oci(0),
lck(1),
tim(2),
deg(3),
bdi(4),
ssf(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the defect condition of the entity, if
any. The value of this object is unspecified if
optIfODUkNimRowStatus has any value other than
active(1)."
::= { optIfODUkNimConfigEntry 9 }
optIfODUkNimRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This columnar object is used for creating and deleting
a conceptual row of the optIfODUkNim config table.
It is used to model the activateNim and deactivateNim
operations of an OTUk_CTP for non-intrusive monitoring
control as defined in G.874.1. Setting RowStatus to
createAndGo or createAndWait implies activateNim.
Setting RowStatus to destroy implies deactivateNim."
::= { optIfODUkNimConfigEntry 10 }
-- GCC12 config table
optIfGCC12ConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfGCC12ConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of GCC12 configuration information.
The GCC function processes the GCC overhead bytes passing
through them but leave the remainder of the ODUk overhead
and payload data alone."
::= { optIfODUk 5 }
optIfGCC12ConfigEntry OBJECT-TYPE
SYNTAX OptIfGCC12ConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains GCC12 configuration
information of an interface. Each instance must
correspond to an instance of optIfODUkConfigEntry.
Separate instances providing GCC1-only access and
GCC2-only access may exist for a given ifIndex value,
or a single instance providing GCC1 + GCC2 may exist,
but a GCC1 + GCC2 instance may not coexist with a
GCC1-only or GCC2-only instance.
Instances of this conceptual row persist across agent
restarts."
INDEX { ifIndex, optIfGCC12Codirectional, optIfGCC12GCCAccess }
::= { optIfGCC12ConfigTable 1 }
OptIfGCC12ConfigEntry ::=
SEQUENCE {
optIfGCC12Codirectional TruthValue,
optIfGCC12GCCAccess INTEGER,
optIfGCC12GCCPassThrough TruthValue,
optIfGCC12Application SnmpAdminString,
optIfGCC12RowStatus RowStatus
}
optIfGCC12Codirectional OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the directionality of the GCC12 termination with
respect to the associated ODUk CTP. The value true(1) means
that the sink part of the GCC12 extracts COMMS data from the
signal at the input to the ODUk CTP sink and the source part
of the GCC12 inserts COMMS data into the signal at the output
of the ODUk CTP source. The value false(2) means that the
sink part of the GCC12 extracts COMMS data from the signal at
the output of the ODUk CTP source and the source part of the
GCC12 inserts COMMS data into the signal at the input of the
ODUk CTP sink. This attribute may assume either value when
the corresponding instance of optIfODUkTtpPresent has the
value false(2). When the value of the corresponding instance
of optIfODUkTtpPresent is true(1) then the only value allowed
for this attribute is true(1)."
::= { optIfGCC12ConfigEntry 1 }
optIfGCC12GCCAccess OBJECT-TYPE
SYNTAX INTEGER {
gcc1 (1),
gcc2 (2),
gcc1and2 (3)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the GCC access represented by the entity."
::= { optIfGCC12ConfigEntry 2 }
optIfGCC12GCCPassThrough OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls whether the selected GCC overhead bytes are passed
through or modified. The value true(1) means that the selected
GCC overhead bytes are passed through unmodified from the ODUk
CTP input to the ODUk CTP output. The value false(2) means that
the selected GCC overhead bytes are set to zero at the ODUk CTP
output after the extraction of the COMMS data. This object has
no effect if the corresponding instance of optIfODUkTtpPresent
has the value true(1).
The value of this object may not be changed when
optIfGCC12RowStatus has the value active(1)."
::= { optIfGCC12ConfigEntry 3 }
optIfGCC12Application OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the application transported by the GCC12 entity.
Example applications are ECC, User data channel.
The value of this object may not be changed when
optIfGCC12RowStatus has the value active(1)."
::= { optIfGCC12ConfigEntry 4 }
optIfGCC12RowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This columnar object is used for creating and deleting
a conceptual row of the optIfGCC12 config table. It is
used to model the addGCC12Access and removeGCC12Access
operations of an ODUk_CTP or ODUk_TTP for GCC12 access
control as defined in G.874.1. Setting RowStatus to
createAndGo or createAndWait implies addGCC12Access.
Setting RowStatus to destroy implies removeGCC12Access.
Successful addition/removal of the GCC12 access function
will result in updating the
optIfODUkPositionSeqCurrentSize variable and the
optIfODUkPositionSeqTable table of the associated
ODUk entry in the optIfODUkConfigTable."
::= { optIfGCC12ConfigEntry 5 }
-- the optIfODUkT group
-- This group handles the configuration information
-- for the ODUkT layers.
-- ODUkT config table
optIfODUkTConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfODUkTConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of ODUkT configuration information."
::= { optIfODUkT 1 }
optIfODUkTConfigEntry OBJECT-TYPE
SYNTAX OptIfODUkTConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains ODUkT configuration
information of an interface. Each instance must
correspond to an instance of optIfODUkConfigEntry.
Rows in this table are mutually exclusive with rows
in the ODUkT NIM config table -- in other words, this
row object may not be instantiated for a given pair
of ifIndex and TCM field values if a corresponding
instance of optIfODUkTNimConfigEntry already exists.
Instances of this conceptual row persist across agent
restarts. Except where noted otherwise, read-create
columns other than the status column may be modified
while the row is active."
INDEX { ifIndex, optIfODUkTTcmField, optIfODUkTCodirectional }
::= { optIfODUkTConfigTable 1 }
OptIfODUkTConfigEntry ::=
SEQUENCE {
optIfODUkTTcmField Unsigned32,
optIfODUkTCodirectional TruthValue,
optIfODUkTTraceIdentifierTransmitted OptIfTxTI,
optIfODUkTDAPIExpected OptIfExDAPI,
optIfODUkTSAPIExpected OptIfExSAPI,
optIfODUkTTraceIdentifierAccepted OptIfAcTI,
optIfODUkTTIMDetMode OptIfTIMDetMode,
optIfODUkTTIMActEnabled TruthValue,
optIfODUkTDEGThr OptIfDEGThr,
optIfODUkTDEGM OptIfDEGM,
optIfODUkTSinkMode INTEGER,
optIfODUkTSinkLockSignalAdminState INTEGER,
optIfODUkTSourceLockSignalAdminState INTEGER,
optIfODUkTCurrentStatus BITS,
optIfODUkTRowStatus RowStatus
}
optIfODUkTTcmField OBJECT-TYPE
SYNTAX Unsigned32 (1..6)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the tandem connection monitoring
field of the ODUk OH. Valid values are
integers from 1 to 6."
::= { optIfODUkTConfigEntry 1 }
optIfODUkTCodirectional OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the directionality of the ODUkT termination point with
respect to the associated ODUk CTP. The value true(1) means
that the sink part of the ODUkT TP extracts TCM data from the
signal at the input to the ODUk CTP sink and the source part
of the ODUkT TP inserts TCM data into the signal at the output
of the ODUk CTP source. The value false(2) means that the
sink part of the ODUkT TP extracts TCM data from the signal at
the output of the ODUk CTP source and the source part of the
ODUkT TP inserts TCM data into the signal at the input of the
ODUk CTP sink. This attribute may assume either value when
the corresponding instance of optIfODUkTtpPresent has the
value false(2). When the value of the corresponding instance
of optIfODUkTtpPresent is true(1) then the only value allowed
for this attribute is true(1)."
::= { optIfODUkTConfigEntry 2 }
optIfODUkTTraceIdentifierTransmitted OBJECT-TYPE
SYNTAX OptIfTxTI
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The trace identifier transmitted.
This object is applicable only to the following three cases.
(i) optIfODUkDirectionality has the value bidirectional(3), or
(ii) optIfODUkDirectionality has the value sink(1) and
optIfODUkTCodirectional has the value false(2), or
(iii) optIfODUkDirectionality has the value source(3) and
optIfODUkTCodirectional has the value true(1).
It must not be instantiated in rows for all other cases."
::= { optIfODUkTConfigEntry 3 }
optIfODUkTDAPIExpected OBJECT-TYPE
SYNTAX OptIfExDAPI
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The DAPI expected by the receiver.
This object is applicable only to the following three cases.
(i) optIfODUkDirectionality has the value bidirectional(3), or
(ii) optIfODUkDirectionality has the value sink(1) and
optIfODUkTCodirectional has the value true(1), or
(iii) optIfODUkDirectionality has the value source(3) and
optIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.
This object has no effect when optIfODUkTTIMDetMode has
the value off(1)."
::= { optIfODUkTConfigEntry 4 }
optIfODUkTSAPIExpected OBJECT-TYPE
SYNTAX OptIfExSAPI
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The SAPI expected by the receiver.
This object is applicable only to the following three cases.
(i) optIfODUkDirectionality has the value bidirectional(3), or
(ii) optIfODUkDirectionality has the value sink(1) and
optIfODUkTCodirectional has the value true(1), or
(iii) optIfODUkDirectionality has the value source(3) and
optIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.
This object has no effect when optIfODUkTTIMDetMode has
the value off(1)."
::= { optIfODUkTConfigEntry 5 }
optIfODUkTTraceIdentifierAccepted OBJECT-TYPE
SYNTAX OptIfAcTI
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual trace identifier accepted.
This object is applicable only to the following three cases.
(i) optIfODUkDirectionality has the value bidirectional(3), or
(ii) optIfODUkDirectionality has the value sink(1) and
optIfODUkTCodirectional has the value true(1), or
(iii) optIfODUkDirectionality has the value source(3) and
optIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.
The value of this object is unspecified when
optIfODUkTCurrentStatus indicates a near-end defect
(i.e., oci(0), lck(1), ssf(5)) that prevents extraction
of the trace message."
::= { optIfODUkTConfigEntry 6 }
optIfODUkTTIMDetMode OBJECT-TYPE
SYNTAX OptIfTIMDetMode
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the mode of the Trace Identifier Mismatch (TIM)
Detection function.
This object is applicable only to the following three cases.
(i) optIfODUkDirectionality has the value bidirectional(3), or
(ii) optIfODUkDirectionality has the value sink(1) and
optIfODUkTCodirectional has the value true(1), or
(iii) optIfODUkDirectionality has the value source(3) and
optIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.
The default value of this object is off(1)."
::= { optIfODUkTConfigEntry 7 }
optIfODUkTTIMActEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether the Trace Identifier Mismatch (TIM)
Consequent Action function is enabled.
This object is applicable only to the following three cases.
(i) optIfODUkDirectionality has the value bidirectional(3), or
(ii) optIfODUkDirectionality has the value sink(1) and
optIfODUkTCodirectional has the value true(1), or
(iii) optIfODUkDirectionality has the value source(3) and
optIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.
This object has no effect when optIfODUkTTIMDetMode has
the value off(1).
The default value of this object is false(2)."
::= { optIfODUkTConfigEntry 8 }
optIfODUkTDEGThr OBJECT-TYPE
SYNTAX OptIfDEGThr
UNITS "percentage"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the threshold level for declaring a performance
monitoring (PM) Second to be bad. A PM Second is declared bad if
the percentage of detected errored blocks in that second is
greater than or equal to optIfODUkTDEGThr.
This object is applicable only to the following three cases.
(i) optIfODUkDirectionality has the value bidirectional(3), or
(ii) optIfODUkDirectionality has the value sink(1) and
optIfODUkTCodirectional has the value true(1), or
(iii) optIfODUkDirectionality has the value source(3) and
optIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.
The default value of this object is Severely Errored Second
(SES) Estimator (See ITU-T G.7710)."
::= { optIfODUkTConfigEntry 9 }
optIfODUkTDEGM OBJECT-TYPE
SYNTAX OptIfDEGM
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the threshold level for declaring a Degraded Signal
defect (dDEG). A dDEG shall be declared if optIfODUkTDEGM
consecutive bad PM Seconds are detected.
This object is applicable only to the following three cases.
(i) optIfODUkDirectionality has the value bidirectional(3), or
(ii) optIfODUkDirectionality has the value sink(1) and
optIfODUkTCodirectional has the value true(1), or
(iii) optIfODUkDirectionality has the value source(3) and
optIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.
The default value of this object is 7 (See ITU-T G.7710)."
::= { optIfODUkTConfigEntry 10 }
optIfODUkTSinkMode OBJECT-TYPE
SYNTAX INTEGER {
operational (1),
monitor (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable specifies the TCM mode at the entity.
The value operational(1) means that TCM Overhead (TCMOH)
processes (see ITU-T G.798) shall be
performed and consequent actions for AIS, Trail
Signal Fail (TSF), Trail Signal Degraded (TSD) shall be
initiated in case of defects.
The value monitor(2) means that TCMOH processes shall be
performed but consequent actions for AIS, Trail
Server Failure (TSF), Trail Server Degraded (TSD) shall _not_ be
initiated in case of defects.
This object is applicable only when the value of
optIfODUkTtpPresent is false(2) and also either one of the
following three cases holds:
(i) optIfODUkDirectionality has the value bidirectional(3), or
(ii) optIfODUkDirectionality has the value sink(1) and
optIfODUkTCodirectional has the value true(1), or
(iii) optIfODUkDirectionality has the value source(3) and
optIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases."
::= { optIfODUkTConfigEntry 11 }
optIfODUkTSinkLockSignalAdminState OBJECT-TYPE
SYNTAX INTEGER {
locked(1),
normal(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Provides the capability to provision the LOCK signal, which
is one of the ODUk maintenance signals, at the ODUKT sink. When
a Tandem Connection endpoint is set to admin state locked,
it inserts the ODUk-LCK signal in the sink direction.
This object is applicable only when the value of
optIfODUkTtpPresent is false(2) and also either one of the
following three cases holds:
(i) optIfODUkDirectionality has the value bidirectional(3), or
(ii) optIfODUkDirectionality has the value sink(1) and
optIfODUkTCodirectional has the value true(1), or
(iii) optIfODUkDirectionality has the value source(3) and
optIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases."
::= { optIfODUkTConfigEntry 12 }
optIfODUkTSourceLockSignalAdminState OBJECT-TYPE
SYNTAX INTEGER {
locked(1),
normal(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Provides the capability to provision the LOCK signal, which
is one of the ODUk maintenance signals, at the source.
When a Tandem Connection endpoint is set to admin state
locked, it inserts the ODUk-LCK signal in the source
direction.
This object is applicable only when either one of the
following three cases holds:
(i) optIfODUkDirectionality has the value bidirectional(3), or
(ii) optIfODUkDirectionality has the value sink(1) and
optIfODUkTCodirectional has the value false(2), or
(iii) optIfODUkDirectionality has the value source(3) and
optIfODUkTCodirectional has the value true(1).
It must not be instantiated in rows for all other cases."
::= { optIfODUkTConfigEntry 13 }
optIfODUkTCurrentStatus OBJECT-TYPE
SYNTAX BITS {
oci(0),
lck(1),
tim(2),
deg(3),
bdi(4),
ssf(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the defect condition of the entity, if any.
This object is applicable only when either one of the
following three cases holds:
(i) optIfODUkDirectionality has the value bidirectional(3), or
(ii) optIfODUkDirectionality has the value sink(1) and
optIfODUkTCodirectional has the value true(1), or
(iii) optIfODUkDirectionality has the value source(3) and
optIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases."
::= { optIfODUkTConfigEntry 14 }
optIfODUkTRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This columnar object is used for creating and deleting a
conceptual row of the optIfODUkT config table.
It is used to model the addTCM and removeTCM operations of an
ODUk_CTP or ODUk_TTP for Tandem connection monitoring as defined
in ITU-T G.874.1.
Setting RowStatus to createAndGo or createAndWait implies addTCM.
Setting RowStatus to destroy implies removeTCM.
Successful addition/removal of TCM will result in updating the
optIfODUkTcmFieldsInUse and optIfODUkPositionSeqCurrentSize
variables and the optIfODUkPositionSeqTable table of the
associated ODUk entry in the optIfODUkConfigTable."
::= { optIfODUkTConfigEntry 15 }
-- ODUkT Non-intrusive monitoring (Nim) config table
optIfODUkTNimConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptIfODUkTNimConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of ODUkTNim configuration information."
::= { optIfODUkT 2 }
optIfODUkTNimConfigEntry OBJECT-TYPE
SYNTAX OptIfODUkTNimConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row that contains ODUkTNim configuration
information of an interface. Each instance must
correspond to an instance of optIfODUkConfigEntry.
Rows in this table are mutually exclusive with rows
in the ODUkT config table -- in other words, this
row object may not be instantiated for a given pair
of ifIndex and TCM field values if a corresponding
instance of optIfODUkTConfigEntry already exists.
Instances of this conceptual row persist across
agent restarts, and read-create columns other
than the status column may be modified while the
row is active."
INDEX {ifIndex, optIfODUkTNimTcmField, optIfODUkTNimDirectionality}
::= { optIfODUkTNimConfigTable 1 }
OptIfODUkTNimConfigEntry ::=
SEQUENCE {
optIfODUkTNimTcmField Unsigned32,
optIfODUkTNimDirectionality OptIfSinkOrSource,
optIfODUkTNimDAPIExpected OptIfExDAPI,
optIfODUkTNimSAPIExpected OptIfExSAPI,
optIfODUkTNimTraceIdentifierAccepted OptIfAcTI,
optIfODUkTNimTIMDetMode OptIfTIMDetMode,
optIfODUkTNimTIMActEnabled TruthValue,
optIfODUkTNimDEGThr OptIfDEGThr,
optIfODUkTNimDEGM OptIfDEGM,
optIfODUkTNimCurrentStatus BITS,
optIfODUkTNimRowStatus RowStatus
}
optIfODUkTNimTcmField OBJECT-TYPE
SYNTAX Unsigned32 (1..6)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the tandem connection monitoring
field of the ODUk OH on which non-intrusive monitoring
is performed. Valid values are
integers from 1 to 6."
::= { optIfODUkTNimConfigEntry 1 }
optIfODUkTNimDirectionality OBJECT-TYPE
SYNTAX OptIfSinkOrSource
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Specifies the monitor point for the ODUk TCM non-intrusive
monitoring function. The value source(2) is not allowed
if the corresponding instance of optIfODUkDirectionality
has the value sink(1), and the value sink(1) is not allowed
if the corresponding instance of optIfODUkDirectionality
has the value source(2). Either the value sink(1) or
source(2) is allowed if the corresponding instance of
optIfODUkDirectionality has the value bidirectional(3).
The value sink(1) means monitoring at the sink direction
TCM signal of the ODUk CTP.
The value source(2) means monitoring at the source direction
path signal of the ODUk CTP."
::= { optIfODUkTNimConfigEntry 2 }
optIfODUkTNimDAPIExpected OBJECT-TYPE
SYNTAX OptIfExDAPI
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The DAPI expected by the receiver.
This object has no effect if optIfODUkTNimTIMDetMode has
the value off(1) or sapi(3)."
::= { optIfODUkTNimConfigEntry 3 }
optIfODUkTNimSAPIExpected OBJECT-TYPE
SYNTAX OptIfExSAPI
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The SAPI expected by the receiver.
This object has no effect if optIfODUkTNimTIMDetMode has
the value off(1) or dapi(2)."
::= { optIfODUkTNimConfigEntry 4 }
optIfODUkTNimTraceIdentifierAccepted OBJECT-TYPE
SYNTAX OptIfAcTI
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual trace identifier accepted. The value of
this object is unspecified if optIfODUkTNimCurrentStatus
has any of the bit positions oci(0), lck(1), or ssf(5)
set or if optIfODUkTNimRowStatus has any value other
than active(1)."
::= { optIfODUkTNimConfigEntry 5 }
optIfODUkTNimTIMDetMode OBJECT-TYPE
SYNTAX OptIfTIMDetMode
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the mode of the Trace Identifier Mismatch (TIM)
Detection function."
::= { optIfODUkTNimConfigEntry 6 }
optIfODUkTNimTIMActEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether the Trace Identifier Mismatch (TIM)
Consequent Action function is enabled."
::= { optIfODUkTNimConfigEntry 7 }
optIfODUkTNimDEGThr OBJECT-TYPE
SYNTAX OptIfDEGThr
UNITS "percentage"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the threshold level for declaring a performance
monitoring (PM) Second to be bad. A PM Second is declared bad if
the percentage of detected errored blocks in that second is
greater than or equal to optIfODUkTNimDEGThr."
::= { optIfODUkTNimConfigEntry 8 }
optIfODUkTNimDEGM OBJECT-TYPE
SYNTAX OptIfDEGM
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the threshold level for declaring a Degraded Signal
defect (dDEG). A dDEG shall be declared if optIfODUkTNimDEGM
consecutive bad PM Seconds are detected."
::= { optIfODUkTNimConfigEntry 9 }
optIfODUkTNimCurrentStatus OBJECT-TYPE
SYNTAX BITS {
oci(0),
lck(1),
tim(2),
deg(3),
bdi(4),
ssf(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the defect condition of the entity, if any.
The value of this object is unspecified if
optIfODUkTNimRowStatus has any value other than
active(1)."
::= { optIfODUkTNimConfigEntry 10 }
optIfODUkTNimRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This columnar object is used for creating and deleting a
conceptual row of the optIfODUkTNim config table.
It is used to model the addTCM and removeTCM operations of an
ODUk_CTP or ODUk_TTP for non-intrusive Tandem connection
monitoring as defined in ITU-T G.874.1.
Setting RowStatus to createAndGo or createAndWait implies addTCM.
Setting RowStatus to destroy implies removeTCM.
Successful addition/removal of Nim TCM will result in updating
the optIfODUkPositionSeqCurrentSize variable and the
optIfODUkPositionSeqTable table of the associated ODUk entry
in the optIfODUkConfigTable."
::= { optIfODUkTNimConfigEntry 11 }
-- units of conformance
optIfOTMnGroup OBJECT-GROUP
OBJECTS {
optIfOTMnOrder,
optIfOTMnReduced,
optIfOTMnBitRates,
optIfOTMnInterfaceType,
optIfOTMnTcmMax,
optIfOTMnOpticalReach
}
STATUS current
DESCRIPTION
"A collection of OTMn structure information objects."
::= { optIfGroups 1 }
optIfPerfMonGroup OBJECT-GROUP
OBJECTS {
optIfPerfMonCurrentTimeElapsed,
optIfPerfMonCurDayTimeElapsed,
optIfPerfMonIntervalNumIntervals,
optIfPerfMonIntervalNumInvalidIntervals
}
STATUS current
DESCRIPTION
"A collection of performance monitoring interval objects."
::= { optIfGroups 2 }
optIfOTSnCommonGroup OBJECT-GROUP
OBJECTS {
optIfOTSnDirectionality
}
STATUS current
DESCRIPTION
"A collection of configuration objects
applicable to all OTSn interfaces."
::= { optIfGroups 3 }
optIfOTSnSourceGroupFull OBJECT-GROUP
OBJECTS {
optIfOTSnTraceIdentifierTransmitted
}
STATUS current
DESCRIPTION
"A collection of configuration objects
applicable to full-functionality/IaDI OTSn
interfaces that support source functions."
::= { optIfGroups 4 }
optIfOTSnAPRStatusGroup OBJECT-GROUP
OBJECTS {
optIfOTSnAprStatus
}
STATUS current
DESCRIPTION
"A collection of objects applicable to
OTSn interfaces that support Automatic
Power Reduction functions."
::= { optIfGroups 5 }
optIfOTSnAPRControlGroup OBJECT-GROUP
OBJECTS {
optIfOTSnAprControl
}
STATUS current
DESCRIPTION
"A collection of objects applicable to
OTSn interfaces that provide Automatic
Power Reduction control functions."
::= { optIfGroups 6 }
optIfOTSnSinkGroupBasic OBJECT-GROUP
OBJECTS {
optIfOTSnCurrentStatus
}
STATUS current
DESCRIPTION
"A collection of configuration objects
applicable to all OTSn interfaces that
support sink functions."
::= { optIfGroups 7 }
optIfOTSnSinkGroupFull OBJECT-GROUP
OBJECTS {
optIfOTSnDAPIExpected,
optIfOTSnSAPIExpected,
optIfOTSnTraceIdentifierAccepted,
optIfOTSnTIMDetMode,
optIfOTSnTIMActEnabled
}
STATUS current
DESCRIPTION
"A collection of configuration objects
applicable to full-functionality/IaDI OTSn
interfaces that support sink functions."
::= { optIfGroups 8 }
optIfOTSnSinkPreOtnPMGroup OBJECT-GROUP
OBJECTS {
optIfOTSnSinkCurrentSuspectedFlag,
optIfOTSnSinkCurrentInputPower,
optIfOTSnSinkCurrentLowInputPower,
optIfOTSnSinkCurrentHighInputPower,
optIfOTSnSinkCurrentOutputPower,
optIfOTSnSinkCurrentLowOutputPower,
optIfOTSnSinkCurrentHighOutputPower,
optIfOTSnSinkIntervalSuspectedFlag,
optIfOTSnSinkIntervalLastInputPower,
optIfOTSnSinkIntervalLowInputPower,
optIfOTSnSinkIntervalHighInputPower,
optIfOTSnSinkIntervalLastOutputPower,
optIfOTSnSinkIntervalLowOutputPower,
optIfOTSnSinkIntervalHighOutputPower,
optIfOTSnSinkCurDaySuspectedFlag,
optIfOTSnSinkCurDayLowInputPower,
optIfOTSnSinkCurDayHighInputPower,
optIfOTSnSinkCurDayLowOutputPower,
optIfOTSnSinkCurDayHighOutputPower,
optIfOTSnSinkPrevDaySuspectedFlag,
optIfOTSnSinkPrevDayLastInputPower,
optIfOTSnSinkPrevDayLowInputPower,
optIfOTSnSinkPrevDayHighInputPower,
optIfOTSnSinkPrevDayLastOutputPower,
optIfOTSnSinkPrevDayLowOutputPower,
optIfOTSnSinkPrevDayHighOutputPower
}
STATUS current
DESCRIPTION
"A collection of pre-OTN performance monitoring
objects applicable to OTSn interfaces that
support sink functions."
::= { optIfGroups 9 }
optIfOTSnSinkPreOtnPMThresholdGroup OBJECT-GROUP
OBJECTS {
optIfOTSnSinkCurrentLowerInputPowerThreshold,
optIfOTSnSinkCurrentUpperInputPowerThreshold,
optIfOTSnSinkCurrentLowerOutputPowerThreshold,
optIfOTSnSinkCurrentUpperOutputPowerThreshold
}
STATUS current
DESCRIPTION
"A collection of pre-OTN performance monitoring
threshold objects applicable to OTSn interfaces
that support sink functions."
::= { optIfGroups 10 }
optIfOTSnSourcePreOtnPMGroup OBJECT-GROUP
OBJECTS {
optIfOTSnSrcCurrentSuspectedFlag,
optIfOTSnSrcCurrentOutputPower,
optIfOTSnSrcCurrentLowOutputPower,
optIfOTSnSrcCurrentHighOutputPower,
optIfOTSnSrcCurrentInputPower,
optIfOTSnSrcCurrentLowInputPower,
optIfOTSnSrcCurrentHighInputPower,
optIfOTSnSrcIntervalSuspectedFlag,
optIfOTSnSrcIntervalLastOutputPower,
optIfOTSnSrcIntervalLowOutputPower,
optIfOTSnSrcIntervalHighOutputPower,
optIfOTSnSrcIntervalLastInputPower,
optIfOTSnSrcIntervalLowInputPower,
optIfOTSnSrcIntervalHighInputPower,
optIfOTSnSrcCurDaySuspectedFlag,
optIfOTSnSrcCurDayLowOutputPower,
optIfOTSnSrcCurDayHighOutputPower,
optIfOTSnSrcCurDayLowInputPower,
optIfOTSnSrcCurDayHighInputPower,
optIfOTSnSrcPrevDaySuspectedFlag,
optIfOTSnSrcPrevDayLastOutputPower,
optIfOTSnSrcPrevDayLowOutputPower,
optIfOTSnSrcPrevDayHighOutputPower,
optIfOTSnSrcPrevDayLastInputPower,
optIfOTSnSrcPrevDayLowInputPower,
optIfOTSnSrcPrevDayHighInputPower
}
STATUS current
DESCRIPTION
"A collection of pre-OTN performance monitoring
objects applicable to OTSn interfaces that
support source functions."
::= { optIfGroups 11 }
optIfOTSnSourcePreOtnPMThresholdGroup OBJECT-GROUP
OBJECTS {
optIfOTSnSrcCurrentLowerOutputPowerThreshold,
optIfOTSnSrcCurrentUpperOutputPowerThreshold,
optIfOTSnSrcCurrentLowerInputPowerThreshold,
optIfOTSnSrcCurrentUpperInputPowerThreshold
}
STATUS current
DESCRIPTION
"A collection of pre-OTN performance monitoring
threshold objects applicable to OTSn interfaces
that support source functions."
::= { optIfGroups 12 }
optIfOMSnCommonGroup OBJECT-GROUP
OBJECTS {
optIfOMSnDirectionality
}
STATUS current
DESCRIPTION
"A collection of configuration objects
applicable to all OMSn interfaces."
::= { optIfGroups 13 }
optIfOMSnSinkGroupBasic OBJECT-GROUP
OBJECTS {
optIfOMSnCurrentStatus
}
STATUS current
DESCRIPTION
"A collection of configuration objects
applicable to all OMSn interfaces that
support sink functions."
::= { optIfGroups 14 }
optIfOMSnSinkPreOtnPMGroup OBJECT-GROUP
OBJECTS {
optIfOMSnSinkCurrentSuspectedFlag,
optIfOMSnSinkCurrentAggregatedInputPower,
optIfOMSnSinkCurrentLowAggregatedInputPower,
optIfOMSnSinkCurrentHighAggregatedInputPower,
optIfOMSnSinkCurrentOutputPower,
optIfOMSnSinkCurrentLowOutputPower,
optIfOMSnSinkCurrentHighOutputPower,
optIfOMSnSinkIntervalSuspectedFlag,
optIfOMSnSinkIntervalLastAggregatedInputPower,
optIfOMSnSinkIntervalLowAggregatedInputPower,
optIfOMSnSinkIntervalHighAggregatedInputPower,
optIfOMSnSinkIntervalLastOutputPower,
optIfOMSnSinkIntervalLowOutputPower,
optIfOMSnSinkIntervalHighOutputPower,
optIfOMSnSinkCurDaySuspectedFlag,
optIfOMSnSinkCurDayLowAggregatedInputPower,
optIfOMSnSinkCurDayHighAggregatedInputPower,
optIfOMSnSinkCurDayLowOutputPower,
optIfOMSnSinkCurDayHighOutputPower,
optIfOMSnSinkPrevDaySuspectedFlag,
optIfOMSnSinkPrevDayLastAggregatedInputPower,
optIfOMSnSinkPrevDayLowAggregatedInputPower,
optIfOMSnSinkPrevDayHighAggregatedInputPower,
optIfOMSnSinkPrevDayLastOutputPower,
optIfOMSnSinkPrevDayLowOutputPower,
optIfOMSnSinkPrevDayHighOutputPower
}
STATUS current
DESCRIPTION
"A collection of pre-OTN performance monitoring
objects applicable to OMSn interfaces that
support sink functions."
::= { optIfGroups 15 }
optIfOMSnSinkPreOtnPMThresholdGroup OBJECT-GROUP
OBJECTS {
optIfOMSnSinkCurrentLowerInputPowerThreshold,
optIfOMSnSinkCurrentUpperInputPowerThreshold,
optIfOMSnSinkCurrentLowerOutputPowerThreshold,
optIfOMSnSinkCurrentUpperOutputPowerThreshold
}
STATUS current
DESCRIPTION
"A collection of pre-OTN performance monitoring
threshold objects applicable to OMSn interfaces
that support sink functions."
::= { optIfGroups 16 }
optIfOMSnSourcePreOtnPMGroup OBJECT-GROUP
OBJECTS {
optIfOMSnSrcCurrentSuspectedFlag,
optIfOMSnSrcCurrentOutputPower,
optIfOMSnSrcCurrentLowOutputPower,
optIfOMSnSrcCurrentHighOutputPower,
optIfOMSnSrcCurrentAggregatedInputPower,
optIfOMSnSrcCurrentLowAggregatedInputPower,
optIfOMSnSrcCurrentHighAggregatedInputPower,
optIfOMSnSrcIntervalSuspectedFlag,
optIfOMSnSrcIntervalLastOutputPower,
optIfOMSnSrcIntervalLowOutputPower,
optIfOMSnSrcIntervalHighOutputPower,
optIfOMSnSrcIntervalLastAggregatedInputPower,
optIfOMSnSrcIntervalLowAggregatedInputPower,
optIfOMSnSrcIntervalHighAggregatedInputPower,
optIfOMSnSrcCurDaySuspectedFlag,
optIfOMSnSrcCurDayLowOutputPower,
optIfOMSnSrcCurDayHighOutputPower,
optIfOMSnSrcCurDayLowAggregatedInputPower,
optIfOMSnSrcCurDayHighAggregatedInputPower,
optIfOMSnSrcPrevDaySuspectedFlag,
optIfOMSnSrcPrevDayLastOutputPower,
optIfOMSnSrcPrevDayLowOutputPower,
optIfOMSnSrcPrevDayHighOutputPower,
optIfOMSnSrcPrevDayLastAggregatedInputPower,
optIfOMSnSrcPrevDayLowAggregatedInputPower,
optIfOMSnSrcPrevDayHighAggregatedInputPower
}
STATUS current
DESCRIPTION
"A collection of pre-OTN performance monitoring
objects applicable to OMSn interfaces that
support source functions."
::= { optIfGroups 17 }
optIfOMSnSourcePreOtnPMThresholdGroup OBJECT-GROUP
OBJECTS {
optIfOMSnSrcCurrentLowerOutputPowerThreshold,
optIfOMSnSrcCurrentUpperOutputPowerThreshold,
optIfOMSnSrcCurrentLowerInputPowerThreshold,
optIfOMSnSrcCurrentUpperInputPowerThreshold
}
STATUS current
DESCRIPTION
"A collection of pre-OTN performance monitoring
threshold objects applicable to OMSn interfaces that
that support source functions."
::= { optIfGroups 18 }
optIfOChGroupCommonGroup OBJECT-GROUP
OBJECTS {
optIfOChGroupDirectionality
}
STATUS current
DESCRIPTION
"A collection of configuration objects
applicable to all OChGroup interfaces."
::= { optIfGroups 19 }
optIfOChGroupSinkPreOtnPMGroup OBJECT-GROUP
OBJECTS {
optIfOChGroupSinkCurrentSuspectedFlag,
optIfOChGroupSinkCurrentAggregatedInputPower,
optIfOChGroupSinkCurrentLowAggregatedInputPower,
optIfOChGroupSinkCurrentHighAggregatedInputPower,
optIfOChGroupSinkCurrentOutputPower,
optIfOChGroupSinkCurrentLowOutputPower,
optIfOChGroupSinkCurrentHighOutputPower,
optIfOChGroupSinkIntervalSuspectedFlag,
optIfOChGroupSinkIntervalLastAggregatedInputPower,
optIfOChGroupSinkIntervalLowAggregatedInputPower,
optIfOChGroupSinkIntervalHighAggregatedInputPower,
optIfOChGroupSinkIntervalLastOutputPower,
optIfOChGroupSinkIntervalLowOutputPower,
optIfOChGroupSinkIntervalHighOutputPower,
optIfOChGroupSinkCurDaySuspectedFlag,
optIfOChGroupSinkCurDayLowAggregatedInputPower,
optIfOChGroupSinkCurDayHighAggregatedInputPower,
optIfOChGroupSinkCurDayLowOutputPower,
optIfOChGroupSinkCurDayHighOutputPower,
optIfOChGroupSinkPrevDaySuspectedFlag,
optIfOChGroupSinkPrevDayLastAggregatedInputPower,
optIfOChGroupSinkPrevDayLowAggregatedInputPower,
optIfOChGroupSinkPrevDayHighAggregatedInputPower,
optIfOChGroupSinkPrevDayLastOutputPower,
optIfOChGroupSinkPrevDayLowOutputPower,
optIfOChGroupSinkPrevDayHighOutputPower
}
STATUS current
DESCRIPTION
"A collection of pre-OTN performance monitoring
objects applicable to OChGroup interfaces that
support sink functions."
::= { optIfGroups 20 }
optIfOChGroupSinkPreOtnPMThresholdGroup OBJECT-GROUP
OBJECTS {
optIfOChGroupSinkCurrentLowerInputPowerThreshold,
optIfOChGroupSinkCurrentUpperInputPowerThreshold,
optIfOChGroupSinkCurrentLowerOutputPowerThreshold,
optIfOChGroupSinkCurrentUpperOutputPowerThreshold
}
STATUS current
DESCRIPTION
"A collection of pre-OTN performance monitoring
threshold objects applicable to OChGroup interfaces
that support sink functions."
::= { optIfGroups 21 }
optIfOChGroupSourcePreOtnPMGroup OBJECT-GROUP
OBJECTS {
optIfOChGroupSrcCurrentSuspectedFlag,
optIfOChGroupSrcCurrentOutputPower,
optIfOChGroupSrcCurrentLowOutputPower,
optIfOChGroupSrcCurrentHighOutputPower,
optIfOChGroupSrcCurrentAggregatedInputPower,
optIfOChGroupSrcCurrentLowAggregatedInputPower,
optIfOChGroupSrcCurrentHighAggregatedInputPower,
optIfOChGroupSrcIntervalSuspectedFlag,
optIfOChGroupSrcIntervalLastOutputPower,
optIfOChGroupSrcIntervalLowOutputPower,
optIfOChGroupSrcIntervalHighOutputPower,
optIfOChGroupSrcIntervalLastAggregatedInputPower,
optIfOChGroupSrcIntervalLowAggregatedInputPower,
optIfOChGroupSrcIntervalHighAggregatedInputPower,
optIfOChGroupSrcCurDaySuspectedFlag,
optIfOChGroupSrcCurDayLowOutputPower,
optIfOChGroupSrcCurDayHighOutputPower,
optIfOChGroupSrcCurDayLowAggregatedInputPower,
optIfOChGroupSrcCurDayHighAggregatedInputPower,
optIfOChGroupSrcPrevDaySuspectedFlag,
optIfOChGroupSrcPrevDayLastOutputPower,
optIfOChGroupSrcPrevDayLowOutputPower,
optIfOChGroupSrcPrevDayHighOutputPower,
optIfOChGroupSrcPrevDayLastAggregatedInputPower,
optIfOChGroupSrcPrevDayLowAggregatedInputPower,
optIfOChGroupSrcPrevDayHighAggregatedInputPower
}
STATUS current
DESCRIPTION
"A collection of pre-OTN performance monitoring
objects applicable to OChGroup interfaces that
support source functions."
::= { optIfGroups 22 }
optIfOChGroupSourcePreOtnPMThresholdGroup OBJECT-GROUP
OBJECTS {
optIfOChGroupSrcCurrentLowerOutputPowerThreshold,
optIfOChGroupSrcCurrentUpperOutputPowerThreshold,
optIfOChGroupSrcCurrentLowerInputPowerThreshold,
optIfOChGroupSrcCurrentUpperInputPowerThreshold
}
STATUS current
DESCRIPTION
"A collection of pre-OTN performance monitoring
threshold objects applicable to OChGroup interfaces that
that support source functions."
::= { optIfGroups 23 }
optIfOChCommonGroup OBJECT-GROUP
OBJECTS {
optIfOChDirectionality
}
STATUS current
DESCRIPTION
"A collection of configuration objects
applicable to all OCh interfaces."
::= { optIfGroups 24 }
optIfOChSinkGroupBasic OBJECT-GROUP
OBJECTS {
optIfOChCurrentStatus
}
STATUS current
DESCRIPTION
"A collection of configuration objects
applicable to all OCh interfaces that
support sink functions."
::= { optIfGroups 25 }
optIfOChSinkPreOtnPMGroup OBJECT-GROUP
OBJECTS {
optIfOChSinkCurrentSuspectedFlag,
optIfOChSinkCurrentInputPower,
optIfOChSinkCurrentLowInputPower,
optIfOChSinkCurrentHighInputPower,
optIfOChSinkIntervalSuspectedFlag,
optIfOChSinkIntervalLastInputPower,
optIfOChSinkIntervalLowInputPower,
optIfOChSinkIntervalHighInputPower,
optIfOChSinkCurDaySuspectedFlag,
optIfOChSinkCurDayLowInputPower,
optIfOChSinkCurDayHighInputPower,
optIfOChSinkPrevDaySuspectedFlag,
optIfOChSinkPrevDayLastInputPower,
optIfOChSinkPrevDayLowInputPower,
optIfOChSinkPrevDayHighInputPower
}
STATUS current
DESCRIPTION
"A collection of pre-OTN performance monitoring
objects applicable to OCh interfaces that
support sink functions."
::= { optIfGroups 26 }
optIfOChSinkPreOtnPMThresholdGroup OBJECT-GROUP
OBJECTS {
optIfOChSinkCurrentLowerInputPowerThreshold,
optIfOChSinkCurrentUpperInputPowerThreshold
}
STATUS current
DESCRIPTION
"A collection of pre-OTN performance monitoring
threshold objects applicable to OCh interfaces
that support sink functions."
::= { optIfGroups 27 }
optIfOChSourcePreOtnPMGroup OBJECT-GROUP
OBJECTS {
optIfOChSrcCurrentSuspectedFlag,
optIfOChSrcCurrentOutputPower,
optIfOChSrcCurrentLowOutputPower,
optIfOChSrcCurrentHighOutputPower,
optIfOChSrcIntervalSuspectedFlag,
optIfOChSrcIntervalLastOutputPower,
optIfOChSrcIntervalLowOutputPower,
optIfOChSrcIntervalHighOutputPower,
optIfOChSrcCurDaySuspectedFlag,
optIfOChSrcCurDayLowOutputPower,
optIfOChSrcCurDayHighOutputPower,
optIfOChSrcPrevDaySuspectedFlag,
optIfOChSrcPrevDayLastOutputPower,
optIfOChSrcPrevDayLowOutputPower,
optIfOChSrcPrevDayHighOutputPower
}
STATUS current
DESCRIPTION
"A collection of pre-OTN performance monitoring
objects applicable to OCh interfaces that
support source functions."
::= { optIfGroups 28 }
optIfOChSourcePreOtnPMThresholdGroup OBJECT-GROUP
OBJECTS {
optIfOChSrcCurrentLowerOutputPowerThreshold,
optIfOChSrcCurrentUpperOutputPowerThreshold
}
STATUS current
DESCRIPTION
"A collection of pre-OTN performance monitoring
threshold objects applicable to OCh interfaces
that support source functions."
::= { optIfGroups 29 }
optIfOTUkCommonGroup OBJECT-GROUP
OBJECTS {
optIfOTUkDirectionality,
optIfOTUkBitRateK
}
STATUS current
DESCRIPTION
"A collection of configuration objects
applicable to all OTUk interfaces."
::= { optIfGroups 30 }
optIfOTUkSourceGroup OBJECT-GROUP
OBJECTS {
optIfOTUkTraceIdentifierTransmitted,
optIfOTUkSourceAdaptActive
}
STATUS current
DESCRIPTION
"A collection of configuration objects
applicable to OTUk interfaces that
support source functions."
::= { optIfGroups 31 }
optIfOTUkSinkGroup OBJECT-GROUP
OBJECTS {
optIfOTUkDAPIExpected,
optIfOTUkSAPIExpected,
optIfOTUkTraceIdentifierAccepted,
optIfOTUkTIMDetMode,
optIfOTUkTIMActEnabled,
optIfOTUkDEGThr,
optIfOTUkDEGM,
optIfOTUkSinkAdaptActive,
optIfOTUkSinkFECEnabled,
optIfOTUkCurrentStatus
}
STATUS current
DESCRIPTION
"A collection of configuration objects
applicable to OTUk interfaces that
support sink functions."
::= { optIfGroups 32 }
optIfGCC0Group OBJECT-GROUP
OBJECTS {
optIfGCC0Application,
optIfGCC0RowStatus
}
STATUS current
DESCRIPTION
"A collection of GCC0 configuration objects."
::= { optIfGroups 33 }
optIfODUkGroup OBJECT-GROUP
OBJECTS {
optIfODUkDirectionality,
optIfODUkBitRateK,
optIfODUkTcmFieldsInUse,
optIfODUkPositionSeqCurrentSize,
optIfODUkPositionSeqPosition,
optIfODUkPositionSeqPointer,
optIfODUkTtpPresent
}
STATUS current
DESCRIPTION
"A collection of configuration objects
applicable to all ODUk interfaces."
::= { optIfGroups 34 }
optIfODUkTtpSourceGroup OBJECT-GROUP
OBJECTS {
optIfODUkTtpTraceIdentifierTransmitted
}
STATUS current
DESCRIPTION
"A collection of configuration objects
applicable to all interfaces that support
ODUk trail termination source functions."
::= { optIfGroups 35 }
optIfODUkTtpSinkGroup OBJECT-GROUP
OBJECTS {
optIfODUkTtpDAPIExpected,
optIfODUkTtpSAPIExpected,
optIfODUkTtpTraceIdentifierAccepted,
optIfODUkTtpTIMDetMode,
optIfODUkTtpTIMActEnabled,
optIfODUkTtpDEGThr,
optIfODUkTtpDEGM,
optIfODUkTtpCurrentStatus
}
STATUS current
DESCRIPTION
"A collection of ODUk configuration objects
applicable to all interfaces that support
ODUk trail termination sink functions."
::= { optIfGroups 36 }
optIfODUkNimGroup OBJECT-GROUP
OBJECTS {
optIfODUkNimDAPIExpected,
optIfODUkNimSAPIExpected,
optIfODUkNimTraceIdentifierAccepted,
optIfODUkNimTIMDetMode,
optIfODUkNimTIMActEnabled,
optIfODUkNimDEGThr,
optIfODUkNimDEGM,
optIfODUkNimCurrentStatus,
optIfODUkNimRowStatus
}
STATUS current
DESCRIPTION
"A collection of ODUk Nim configuration objects."
::= { optIfGroups 37 }
optIfGCC12Group OBJECT-GROUP
OBJECTS {
optIfGCC12GCCPassThrough,
optIfGCC12Application,
optIfGCC12RowStatus
}
STATUS current
DESCRIPTION
"A collection of GCC12 configuration objects."
::= { optIfGroups 38 }
optIfODUkTCommonGroup OBJECT-GROUP
OBJECTS {
optIfODUkTRowStatus
}
STATUS current
DESCRIPTION
"A collection of configuration objects
applicable to all ODUkT instances."
::= { optIfGroups 39 }
optIfODUkTSourceGroup OBJECT-GROUP
OBJECTS {
optIfODUkTTraceIdentifierTransmitted,
optIfODUkTSourceLockSignalAdminState
}
STATUS current
DESCRIPTION
"A collection of configuration objects
applicable to all ODUkT instances
that provide source functions."
::= { optIfGroups 40 }
optIfODUkTSinkGroup OBJECT-GROUP
OBJECTS {
optIfODUkTDAPIExpected,
optIfODUkTSAPIExpected,
optIfODUkTTraceIdentifierAccepted,
optIfODUkTTIMDetMode,
optIfODUkTTIMActEnabled,
optIfODUkTDEGThr,
optIfODUkTDEGM,
optIfODUkTCurrentStatus
}
STATUS current
DESCRIPTION
"A collection of configuration objects
applicable to all ODUkT instances
that provide sink functions."
::= { optIfGroups 41 }
optIfODUkTSinkGroupCtp OBJECT-GROUP
OBJECTS {
optIfODUkTSinkMode,
optIfODUkTSinkLockSignalAdminState
}
STATUS current
DESCRIPTION
"A collection of configuration objects
applicable to ODUkT instances not
colocated with an ODUk TTP that
provide sink functions."
::= { optIfGroups 42 }
optIfODUkTNimGroup OBJECT-GROUP
OBJECTS {
optIfODUkTNimDAPIExpected,
optIfODUkTNimSAPIExpected,
optIfODUkTNimTraceIdentifierAccepted,
optIfODUkTNimTIMDetMode,
optIfODUkTNimTIMActEnabled,
optIfODUkTNimDEGThr,
optIfODUkTNimDEGM,
optIfODUkTNimCurrentStatus,
optIfODUkTNimRowStatus
}
STATUS current
DESCRIPTION
"A collection of ODUkT Nim configuration objects."
::= { optIfGroups 43 }
END