OPT-IF-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Gauge32, Integer32,
|
|
Unsigned32, transmission
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, RowPointer, RowStatus, TruthValue
|
|
FROM SNMPv2-TC
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
ifIndex
|
|
FROM IF-MIB;
|
|
|
|
-- This is the MIB module for the OTN Interface objects.
|
|
|
|
optIfMibModule MODULE-IDENTITY
|
|
LAST-UPDATED "200308130000Z"
|
|
ORGANIZATION "IETF AToM MIB Working Group"
|
|
CONTACT-INFO
|
|
"WG charter:
|
|
http://www.ietf.org/html.charters/atommib-charter.html
|
|
|
|
Mailing Lists:
|
|
General Discussion: atommib@research.telcordia.com
|
|
To Subscribe: atommib-request@research.telcordia.com
|
|
Editor: Hing-Kam Lam
|
|
Postal: Lucent Technologies, Room 4C-616
|
|
101 Crawfords Corner Road
|
|
Holmdel, NJ 07733
|
|
Tel: +1 732 949 8338
|
|
Email: hklam@lucent.com"
|
|
DESCRIPTION
|
|
"The MIB module to describe pre-OTN and OTN interfaces.
|
|
|
|
Copyright (C) The Internet Society (2003). This version
|
|
of this MIB module is part of RFC 3591; see the RFC
|
|
itself for full legal notices."
|
|
REVISION "200308130000Z"
|
|
DESCRIPTION
|
|
"Initial version, published as RFC 3591."
|
|
::={ transmission 133 }
|
|
|
|
-- textual conventions
|
|
|
|
OptIfAcTI ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trace identifier (TI) accepted at the receiver."
|
|
SYNTAX OCTET STRING (SIZE(64))
|
|
|
|
OptIfBitRateK ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the index 'k' that is used to
|
|
represent a supported bit rate and the different
|
|
versions of OPUk, ODUk and OTUk.
|
|
Allowed values of k are defined in ITU-T G.709.
|
|
Currently allowed values in G.709 are:
|
|
k=1 represents an approximate bit rate of 2.5 Gbit/s,
|
|
k=2 represents an approximate bit rate of 10 Gbit/s,
|
|
k=3 represents an approximate bit rate of 40 Gbit/s."
|
|
SYNTAX Integer32
|
|
|
|
OptIfDEGM ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a Degraded Signal
|
|
defect (dDEG). A dDEG shall be declared if OptIfDEGM
|
|
consecutive bad PM Seconds are detected."
|
|
SYNTAX Unsigned32 (2..10)
|
|
|
|
OptIfDEGThr ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a performance
|
|
monitoring (PM) Second to be bad. A PM Second is declared bad if
|
|
the percentage of detected errored blocks in that second is
|
|
greater than or equal to OptIfDEGThr."
|
|
SYNTAX Unsigned32 (1..100)
|
|
|
|
OptIfDirectionality ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of an entity."
|
|
SYNTAX INTEGER {
|
|
sink(1),
|
|
source(2),
|
|
bidirectional(3)
|
|
}
|
|
|
|
OptIfSinkOrSource ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of an entity
|
|
that is allowed only to be a source or sink."
|
|
SYNTAX INTEGER {
|
|
sink(1),
|
|
source(2)
|
|
}
|
|
|
|
OptIfExDAPI ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Destination Access Point Identifier (DAPI)
|
|
expected by the receiver."
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
|
|
OptIfExSAPI ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Source Access Point Identifier (SAPI)
|
|
expected by the receiver."
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
|
|
OptIfIntervalNumber ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies a 15-minute interval. The interval
|
|
identified by 1 is the most recently completed interval, and
|
|
the interval identified by n is the interval immediately
|
|
preceding the one identified by n-1."
|
|
SYNTAX Unsigned32 (1..96)
|
|
|
|
OptIfTIMDetMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the mode of the Trace Identifier Mismatch (TIM)
|
|
Detection function."
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
dapi(2),
|
|
sapi(3),
|
|
both(4)
|
|
}
|
|
|
|
OptIfTxTI ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trace identifier (TI) transmitted."
|
|
SYNTAX OCTET STRING (SIZE(64))
|
|
|
|
-- object groups
|
|
|
|
optIfObjects OBJECT IDENTIFIER ::= { optIfMibModule 1 }
|
|
optIfConfs OBJECT IDENTIFIER ::= { optIfMibModule 2 }
|
|
|
|
optIfOTMn OBJECT IDENTIFIER ::= { optIfObjects 1 }
|
|
optIfPerfMon OBJECT IDENTIFIER ::= { optIfObjects 2 }
|
|
optIfOTSn OBJECT IDENTIFIER ::= { optIfObjects 3 }
|
|
optIfOMSn OBJECT IDENTIFIER ::= { optIfObjects 4 }
|
|
optIfOChGroup OBJECT IDENTIFIER ::= { optIfObjects 5 }
|
|
optIfOCh OBJECT IDENTIFIER ::= { optIfObjects 6 }
|
|
|
|
optIfOTUk OBJECT IDENTIFIER ::= { optIfObjects 7 }
|
|
optIfODUk OBJECT IDENTIFIER ::= { optIfObjects 8 }
|
|
optIfODUkT OBJECT IDENTIFIER ::= { optIfObjects 9 }
|
|
|
|
optIfGroups OBJECT IDENTIFIER ::= { optIfConfs 1 }
|
|
optIfCompl OBJECT IDENTIFIER ::= { optIfConfs 2 }
|
|
|
|
-- the optIfOTMn group
|
|
-- This group defines the OTM structure information of an
|
|
-- optical interface.
|
|
|
|
-- OTMn Table
|
|
|
|
optIfOTMnTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTMnEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OTMn structure information."
|
|
::= { optIfOTMn 1 }
|
|
|
|
optIfOTMnEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTMnEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains the OTMn structure
|
|
information of an optical interface."
|
|
INDEX { ifIndex }
|
|
::= { optIfOTMnTable 1 }
|
|
|
|
OptIfOTMnEntry ::=
|
|
SEQUENCE {
|
|
optIfOTMnOrder Unsigned32,
|
|
optIfOTMnReduced TruthValue,
|
|
optIfOTMnBitRates BITS,
|
|
optIfOTMnInterfaceType SnmpAdminString,
|
|
optIfOTMnTcmMax Unsigned32,
|
|
optIfOTMnOpticalReach INTEGER
|
|
}
|
|
|
|
optIfOTMnOrder OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..900)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the order of the OTM, which
|
|
represents the maximum number of wavelengths that can be
|
|
supported at the bit rate(s) supported on the interface."
|
|
::= { optIfOTMnEntry 1 }
|
|
|
|
optIfOTMnReduced OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether a reduced or full
|
|
functionality is supported at the interface. A value of
|
|
true means reduced. A value of false means full."
|
|
::= { optIfOTMnEntry 2 }
|
|
|
|
optIfOTMnBitRates OBJECT-TYPE
|
|
SYNTAX BITS { bitRateK1(0), bitRateK2(1), bitRateK3(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is a bit map representing the bit
|
|
rate or set of bit rates supported on the interface.
|
|
The meaning of each bit position is as follows:
|
|
bitRateK1(0) is set if the 2.5 Gbit/s rate is supported
|
|
bitRateK2(1) is set if the 10 Gbit/s rate is supported
|
|
bitRateK3(2) is set if the 40 Gbit/s rate is supported
|
|
Note that each bit position corresponds to one possible
|
|
value of the type OptIfBitRateK.
|
|
The default value of this attribute is system specific."
|
|
::= { optIfOTMnEntry 3 }
|
|
|
|
optIfOTMnInterfaceType OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the type of interface. The value of
|
|
this attribute will affect the behavior of the OTM with
|
|
respect to presence/absence of OTM Overhead Signal (OOS)
|
|
processing and TCM activation. For an IrDI interface,
|
|
there is no OOS processing and TCM activation is limited
|
|
to n levels as specified by a TCM level threshold.
|
|
|
|
This object contains two fields that are separated by
|
|
whitespace. The possible values are:
|
|
field 1: one of the 4-character ASCII strings
|
|
'IrDI' or 'IaDI'
|
|
field 2: free-form text consisting of printable
|
|
UTF-8 encoded characters
|
|
|
|
Note that field 2 is optional. If it is not present then there
|
|
is no requirement for trailing whitespace after field 1.
|
|
|
|
The default values are as follows:
|
|
field 1: 'IaDI'
|
|
field 2: an empty string."
|
|
|
|
::= { optIfOTMnEntry 4 }
|
|
|
|
optIfOTMnTcmMax OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..6)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the maximum number of TCM
|
|
levels allowed for any Optical Channel contained
|
|
in this OTM. A new TCM activation will be rejected
|
|
if the requested level is greater than the threshold.
|
|
If InterfaceType object specifies a type of 'IaDI'
|
|
for this OTM, then this attribute is irrelevant.
|
|
|
|
Possible values: unsigned integers in the range
|
|
from 0 to 6 inclusive.
|
|
Default value: 3."
|
|
|
|
::= { optIfOTMnEntry 5 }
|
|
|
|
optIfOTMnOpticalReach OBJECT-TYPE
|
|
SYNTAX INTEGER { intraOffice(1), shortHaul(2), longHaul(3),
|
|
veryLongHaul(4), ultraLongHaul(5) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the length the optical signal
|
|
may travel before requiring termination or regeneration.
|
|
The meaning of the enumeration are:
|
|
intraOffice(1) - intra-office (as defined in ITU-T G.957)
|
|
shortHaul(2) - short haul (as defined in ITU-T G.957)
|
|
longHaul(3) - long haul (as defined in ITU-T G.957)
|
|
veryLongHaul(4) - very long haul (as defined in ITU-T G.691)
|
|
ultraLongHaul(5)- ultra long haul (as defined in ITU-T G.691)"
|
|
::= { optIfOTMnEntry 6 }
|
|
|
|
-- the optIfPerfMon group
|
|
-- This group defines performance monitoring objects for all
|
|
-- layers.
|
|
|
|
-- PM interval table
|
|
|
|
optIfPerfMonIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfPerfMonIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of 15-minute performance monitoring interval
|
|
information."
|
|
::= { optIfPerfMon 1 }
|
|
|
|
optIfPerfMonIntervalEntry OBJECT-TYPE
|
|
SYNTAX OptIfPerfMonIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
|
|
DESCRIPTION
|
|
"A conceptual row that contains 15-minute performance
|
|
monitoring interval information of an interface."
|
|
INDEX { ifIndex }
|
|
::= { optIfPerfMonIntervalTable 1 }
|
|
|
|
OptIfPerfMonIntervalEntry ::=
|
|
SEQUENCE {
|
|
optIfPerfMonCurrentTimeElapsed Gauge32,
|
|
optIfPerfMonCurDayTimeElapsed Gauge32,
|
|
optIfPerfMonIntervalNumIntervals Unsigned32,
|
|
optIfPerfMonIntervalNumInvalidIntervals Unsigned32
|
|
}
|
|
|
|
optIfPerfMonCurrentTimeElapsed OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..900)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds elapsed in the current 15-minute
|
|
performance monitoring interval.
|
|
If, for some reason, such as an adjustment in the NE's
|
|
time-of-day clock, the number of seconds elapsed exceeds
|
|
the maximum value, then the maximum value will be returned."
|
|
::= { optIfPerfMonIntervalEntry 1 }
|
|
|
|
optIfPerfMonCurDayTimeElapsed OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..86400)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds elapsed in the current 24-hour interval
|
|
performance monitoring period.
|
|
If, for some reason, such as an adjustment in the NE's
|
|
time-of-day clock, the number of seconds elapsed exceeds
|
|
the maximum value, then the maximum value will be returned."
|
|
::= { optIfPerfMonIntervalEntry 2 }
|
|
|
|
optIfPerfMonIntervalNumIntervals OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of 15-minute intervals for which performance
|
|
monitoring data is available. The number is the same for all
|
|
the associated sub layers of the interface.
|
|
An optical interface must be capable of supporting at least
|
|
n intervals, where n is defined as follows:
|
|
The minimum value of n is 4.
|
|
The default of n is 32.
|
|
The maximum value of n is 96.
|
|
|
|
The value of this object will be n unless performance
|
|
monitoring was (re-)started for the interface within the last
|
|
(n*15) minutes, in which case the value will be the number of
|
|
complete 15-minute intervals since measurement was
|
|
(re-)started."
|
|
::= { optIfPerfMonIntervalEntry 3 }
|
|
|
|
optIfPerfMonIntervalNumInvalidIntervals OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of intervals in the range from 0 to
|
|
optIfPerfMonIntervalNumIntervals for which no performance
|
|
monitoring data is available and/or the data is invalid."
|
|
::= { optIfPerfMonIntervalEntry 4 }
|
|
|
|
-- the optIfOTSn group
|
|
-- This group handles the configuration and performance
|
|
-- monitoring objects for OTS layers.
|
|
|
|
-- OTSn config table
|
|
|
|
optIfOTSnConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTSnConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OTSn configuration information."
|
|
::= { optIfOTSn 1 }
|
|
|
|
optIfOTSnConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTSnConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OTSn configuration
|
|
information of an interface."
|
|
INDEX { ifIndex }
|
|
::= { optIfOTSnConfigTable 1 }
|
|
|
|
OptIfOTSnConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfOTSnDirectionality OptIfDirectionality,
|
|
optIfOTSnAprStatus SnmpAdminString,
|
|
optIfOTSnAprControl SnmpAdminString,
|
|
optIfOTSnTraceIdentifierTransmitted OptIfTxTI,
|
|
optIfOTSnDAPIExpected OptIfExDAPI,
|
|
optIfOTSnSAPIExpected OptIfExSAPI,
|
|
optIfOTSnTraceIdentifierAccepted OptIfAcTI,
|
|
optIfOTSnTIMDetMode OptIfTIMDetMode,
|
|
optIfOTSnTIMActEnabled TruthValue,
|
|
optIfOTSnCurrentStatus BITS
|
|
}
|
|
|
|
optIfOTSnDirectionality OBJECT-TYPE
|
|
SYNTAX OptIfDirectionality
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of the entity."
|
|
::= { optIfOTSnConfigEntry 1 }
|
|
|
|
optIfOTSnAprStatus OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the status of the Automatic
|
|
Power Reduction (APR) function of the entity. Valid
|
|
values are 'on' and 'off'."
|
|
::= { optIfOTSnConfigEntry 2 }
|
|
|
|
optIfOTSnAprControl OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is a UTF-8 encoded string that specifies Automatic
|
|
Power Reduction (APR) control actions requested of this entity
|
|
(when written) and that returns the current APR control state
|
|
of this entity (when read). The values are implementation-defined.
|
|
Any implementation that instantiates this object must document the
|
|
set of values that it allows to be written, the set of values
|
|
that it will return, and what each of those values means."
|
|
::= { optIfOTSnConfigEntry 3 }
|
|
|
|
optIfOTSnTraceIdentifierTransmitted OBJECT-TYPE
|
|
SYNTAX OptIfTxTI
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trace identifier transmitted.
|
|
This object is applicable when optIfOTSnDirectionality has the
|
|
value source(2) or bidirectional(3).
|
|
This object does not apply to reduced-capability systems (i.e.,
|
|
those for which optIfOTMnReduced has the value true(1)) or
|
|
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
|
|
has the value 'IrDI').
|
|
If no value is ever set by a management entity for the object
|
|
optIfOTSnTraceIdentifierTransmitted, system-specific default
|
|
value will be used. Any implementation that instantiates this
|
|
object must document the system-specific default value or how it
|
|
is derived."
|
|
::= { optIfOTSnConfigEntry 4 }
|
|
|
|
optIfOTSnDAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExDAPI
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DAPI expected by the receiver.
|
|
This object is applicable when optIfOTSnDirectionality has the
|
|
value sink(1) or bidirectional(3). It has no effect if
|
|
optIfOTSnTIMDetMode has the value off(1) or sapi(3).
|
|
This object does not apply to reduced-capability systems (i.e.,
|
|
those for which optIfOTMnReduced has the value true(1)) or
|
|
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
|
|
has the value 'IrDI')."
|
|
::= { optIfOTSnConfigEntry 5 }
|
|
|
|
optIfOTSnSAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExSAPI
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SAPI expected by the receiver.
|
|
This object is applicable when optIfOTSnDirectionality has the
|
|
value sink(1) or bidirectional(3). It has no effect if
|
|
optIfOTSnTIMDetMode has the value off(1) or dapi(2).
|
|
This object does not apply to reduced-capability systems (i.e.,
|
|
those for which optIfOTMnReduced has the value true(1)) or
|
|
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
|
|
has the value 'IrDI')."
|
|
::= { optIfOTSnConfigEntry 6 }
|
|
|
|
optIfOTSnTraceIdentifierAccepted OBJECT-TYPE
|
|
SYNTAX OptIfAcTI
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual trace identifier received.
|
|
This object is applicable when optIfOTSnDirectionality has the
|
|
value sink(1) or bidirectional(3). Its value is unspecified
|
|
if optIfOTSnCurrentStatus has either or both of the
|
|
losO(5) and los(6) bits set.
|
|
This object does not apply to reduced-capability systems (i.e.,
|
|
those for which optIfOTMnReduced has the value true(1)) or
|
|
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
|
|
has the value 'IrDI')."
|
|
::= { optIfOTSnConfigEntry 7 }
|
|
|
|
optIfOTSnTIMDetMode OBJECT-TYPE
|
|
SYNTAX OptIfTIMDetMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the mode of the Trace Identifier Mismatch (TIM)
|
|
Detection function. This object is applicable
|
|
when optIfOTSnDirectionality has the value sink(1)
|
|
or bidirectional(3). The default value is off(1).
|
|
This object does not apply to reduced-capability systems (i.e.,
|
|
those for which optIfOTMnReduced has the value true(1)) or
|
|
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
|
|
has the value 'IrDI').
|
|
The default value of this object is off(1)."
|
|
::= { optIfOTSnConfigEntry 8 }
|
|
|
|
optIfOTSnTIMActEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the Trace Identifier Mismatch (TIM)
|
|
Consequent Action function is enabled. This object
|
|
is applicable when optIfOTSnDirectionality has the
|
|
value sink(1) or bidirectional(3). It has no effect
|
|
when the value of optIfOTSnTIMDetMode is off(1).
|
|
This object does not apply to reduced-capability systems (i.e.,
|
|
those for which optIfOTMnReduced has the value true(1)) or
|
|
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
|
|
has the value 'IrDI').
|
|
The default value of this object is false(2)."
|
|
::= { optIfOTSnConfigEntry 9 }
|
|
|
|
optIfOTSnCurrentStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
bdiP(0),
|
|
bdiO(1),
|
|
bdi(2),
|
|
tim(3),
|
|
losP(4),
|
|
losO(5),
|
|
los(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the defect condition of the entity, if any.
|
|
This object is applicable when optIfOTSnDirectionality
|
|
has the value sink(1) or bidirectional(3). In
|
|
reduced-capability systems or at IrDI interfaces
|
|
the only bit position that may be set is los(6)."
|
|
::= { optIfOTSnConfigEntry 10 }
|
|
|
|
-- OTSn sink current table
|
|
-- Contains data for the current 15-minute performance monitoring
|
|
-- interval.
|
|
|
|
optIfOTSnSinkCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTSnSinkCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OTSn sink performance monitoring information for
|
|
the current 15-minute interval."
|
|
::= { optIfOTSn 2 }
|
|
|
|
optIfOTSnSinkCurrentEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTSnSinkCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OTSn sink performance
|
|
monitoring information of an interface for the current
|
|
15-minute interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOTSnSinkCurrentTable 1 }
|
|
|
|
OptIfOTSnSinkCurrentEntry ::=
|
|
SEQUENCE {
|
|
optIfOTSnSinkCurrentSuspectedFlag TruthValue,
|
|
optIfOTSnSinkCurrentInputPower Integer32,
|
|
optIfOTSnSinkCurrentLowInputPower Integer32,
|
|
optIfOTSnSinkCurrentHighInputPower Integer32,
|
|
optIfOTSnSinkCurrentLowerInputPowerThreshold Integer32,
|
|
optIfOTSnSinkCurrentUpperInputPowerThreshold Integer32,
|
|
optIfOTSnSinkCurrentOutputPower Integer32,
|
|
optIfOTSnSinkCurrentLowOutputPower Integer32,
|
|
optIfOTSnSinkCurrentHighOutputPower Integer32,
|
|
optIfOTSnSinkCurrentLowerOutputPowerThreshold Integer32,
|
|
optIfOTSnSinkCurrentUpperOutputPowerThreshold Integer32
|
|
}
|
|
|
|
optIfOTSnSinkCurrentSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOTSnSinkCurrentEntry 1 }
|
|
|
|
optIfOTSnSinkCurrentInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the input."
|
|
::= { optIfOTSnSinkCurrentEntry 2 }
|
|
|
|
optIfOTSnSinkCurrentLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
current 15-minute interval."
|
|
::= { optIfOTSnSinkCurrentEntry 3 }
|
|
|
|
optIfOTSnSinkCurrentHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
current 15-minute interval."
|
|
::= { optIfOTSnSinkCurrentEntry 4 }
|
|
|
|
optIfOTSnSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on input power. If
|
|
optIfOTSnSinkCurrentInputPower drops to this value or below,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOTSnSinkCurrentEntry 5 }
|
|
|
|
optIfOTSnSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on input power. If
|
|
optIfOTSnSinkCurrentInputPower reaches or exceeds this value,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOTSnSinkCurrentEntry 6 }
|
|
|
|
optIfOTSnSinkCurrentOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the output."
|
|
::= { optIfOTSnSinkCurrentEntry 7 }
|
|
|
|
optIfOTSnSinkCurrentLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOTSnSinkCurrentEntry 8 }
|
|
|
|
optIfOTSnSinkCurrentHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOTSnSinkCurrentEntry 9 }
|
|
|
|
optIfOTSnSinkCurrentLowerOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on output power. If
|
|
optIfOTSnSinkCurrentOutputPower drops to this value or below,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOTSnSinkCurrentEntry 10 }
|
|
|
|
optIfOTSnSinkCurrentUpperOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on output power. If
|
|
optIfOTSnSinkCurrentOutputPower reaches or exceeds this value,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOTSnSinkCurrentEntry 11 }
|
|
|
|
-- OTSn sink interval table
|
|
-- Contains data for previous 15-minute performance monitoring
|
|
-- intervals.
|
|
|
|
optIfOTSnSinkIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTSnSinkIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of historical OTSn sink performance monitoring
|
|
information."
|
|
::= { optIfOTSn 3 }
|
|
|
|
optIfOTSnSinkIntervalEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTSnSinkIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OTSn sink performance
|
|
monitoring information of an interface during a particular
|
|
historical interval."
|
|
INDEX { ifIndex, optIfOTSnSinkIntervalNumber }
|
|
::= { optIfOTSnSinkIntervalTable 1 }
|
|
|
|
OptIfOTSnSinkIntervalEntry ::=
|
|
SEQUENCE {
|
|
optIfOTSnSinkIntervalNumber OptIfIntervalNumber,
|
|
optIfOTSnSinkIntervalSuspectedFlag TruthValue,
|
|
optIfOTSnSinkIntervalLastInputPower Integer32,
|
|
optIfOTSnSinkIntervalLowInputPower Integer32,
|
|
optIfOTSnSinkIntervalHighInputPower Integer32,
|
|
optIfOTSnSinkIntervalLastOutputPower Integer32,
|
|
optIfOTSnSinkIntervalLowOutputPower Integer32,
|
|
optIfOTSnSinkIntervalHighOutputPower Integer32
|
|
|
|
}
|
|
|
|
optIfOTSnSinkIntervalNumber OBJECT-TYPE
|
|
SYNTAX OptIfIntervalNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies the interval."
|
|
::= { optIfOTSnSinkIntervalEntry 1 }
|
|
|
|
optIfOTSnSinkIntervalSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOTSnSinkIntervalEntry 2 }
|
|
|
|
optIfOTSnSinkIntervalLastInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the input during the
|
|
interval."
|
|
::= { optIfOTSnSinkIntervalEntry 3 }
|
|
|
|
optIfOTSnSinkIntervalLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
interval."
|
|
::= { optIfOTSnSinkIntervalEntry 4 }
|
|
|
|
|
|
optIfOTSnSinkIntervalHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
interval."
|
|
::= { optIfOTSnSinkIntervalEntry 5 }
|
|
|
|
optIfOTSnSinkIntervalLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOTSnSinkIntervalEntry 6 }
|
|
|
|
optIfOTSnSinkIntervalLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOTSnSinkIntervalEntry 7 }
|
|
|
|
optIfOTSnSinkIntervalHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOTSnSinkIntervalEntry 8 }
|
|
|
|
-- OTSn sink current day table
|
|
-- Contains data for the current 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOTSnSinkCurDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTSnSinkCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
|
|
DESCRIPTION
|
|
"A table of OTSn sink performance monitoring information for
|
|
the current 24-hour interval."
|
|
::= { optIfOTSn 4 }
|
|
|
|
optIfOTSnSinkCurDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTSnSinkCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OTSn sink performance
|
|
monitoring information of an interface for the current
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOTSnSinkCurDayTable 1 }
|
|
|
|
OptIfOTSnSinkCurDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOTSnSinkCurDaySuspectedFlag TruthValue,
|
|
optIfOTSnSinkCurDayLowInputPower Integer32,
|
|
optIfOTSnSinkCurDayHighInputPower Integer32,
|
|
optIfOTSnSinkCurDayLowOutputPower Integer32,
|
|
optIfOTSnSinkCurDayHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOTSnSinkCurDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOTSnSinkCurDayEntry 1 }
|
|
|
|
optIfOTSnSinkCurDayLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
current 24-hour interval."
|
|
::= { optIfOTSnSinkCurDayEntry 2 }
|
|
|
|
optIfOTSnSinkCurDayHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
current 24-hour interval."
|
|
::= { optIfOTSnSinkCurDayEntry 3 }
|
|
|
|
optIfOTSnSinkCurDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOTSnSinkCurDayEntry 4 }
|
|
|
|
optIfOTSnSinkCurDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOTSnSinkCurDayEntry 5 }
|
|
|
|
-- OTSn sink previous day table
|
|
-- Contains data for the previous 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOTSnSinkPrevDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTSnSinkPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OTSn sink performance monitoring information for
|
|
the previous 24-hour interval."
|
|
::= { optIfOTSn 5 }
|
|
|
|
optIfOTSnSinkPrevDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTSnSinkPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OTSn sink performance
|
|
monitoring information of an interface for the previous
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOTSnSinkPrevDayTable 1 }
|
|
|
|
|
|
OptIfOTSnSinkPrevDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOTSnSinkPrevDaySuspectedFlag TruthValue,
|
|
optIfOTSnSinkPrevDayLastInputPower Integer32,
|
|
optIfOTSnSinkPrevDayLowInputPower Integer32,
|
|
optIfOTSnSinkPrevDayHighInputPower Integer32,
|
|
optIfOTSnSinkPrevDayLastOutputPower Integer32,
|
|
optIfOTSnSinkPrevDayLowOutputPower Integer32,
|
|
optIfOTSnSinkPrevDayHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOTSnSinkPrevDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOTSnSinkPrevDayEntry 1 }
|
|
|
|
optIfOTSnSinkPrevDayLastInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSinkPrevDayEntry 2 }
|
|
|
|
optIfOTSnSinkPrevDayLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSinkPrevDayEntry 3 }
|
|
|
|
optIfOTSnSinkPrevDayHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSinkPrevDayEntry 4 }
|
|
|
|
|
|
optIfOTSnSinkPrevDayLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSinkPrevDayEntry 5 }
|
|
|
|
optIfOTSnSinkPrevDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSinkPrevDayEntry 6 }
|
|
|
|
optIfOTSnSinkPrevDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSinkPrevDayEntry 7 }
|
|
|
|
-- OTSn source current table
|
|
-- Contains data for the current 15-minute performance monitoring
|
|
-- interval.
|
|
|
|
optIfOTSnSrcCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTSnSrcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OTSn source performance monitoring information for
|
|
the current 15-minute interval."
|
|
::= { optIfOTSn 6 }
|
|
|
|
optIfOTSnSrcCurrentEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTSnSrcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
|
|
"A conceptual row that contains OTSn source performance
|
|
monitoring information of an interface for the current
|
|
15-minute interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOTSnSrcCurrentTable 1 }
|
|
|
|
OptIfOTSnSrcCurrentEntry ::=
|
|
SEQUENCE {
|
|
optIfOTSnSrcCurrentSuspectedFlag TruthValue,
|
|
optIfOTSnSrcCurrentOutputPower Integer32,
|
|
optIfOTSnSrcCurrentLowOutputPower Integer32,
|
|
optIfOTSnSrcCurrentHighOutputPower Integer32,
|
|
optIfOTSnSrcCurrentLowerOutputPowerThreshold Integer32,
|
|
optIfOTSnSrcCurrentUpperOutputPowerThreshold Integer32,
|
|
optIfOTSnSrcCurrentInputPower Integer32,
|
|
optIfOTSnSrcCurrentLowInputPower Integer32,
|
|
optIfOTSnSrcCurrentHighInputPower Integer32,
|
|
optIfOTSnSrcCurrentLowerInputPowerThreshold Integer32,
|
|
optIfOTSnSrcCurrentUpperInputPowerThreshold Integer32
|
|
}
|
|
|
|
optIfOTSnSrcCurrentSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOTSnSrcCurrentEntry 1 }
|
|
|
|
optIfOTSnSrcCurrentOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the output."
|
|
::= { optIfOTSnSrcCurrentEntry 2 }
|
|
|
|
optIfOTSnSrcCurrentLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOTSnSrcCurrentEntry 3 }
|
|
|
|
|
|
optIfOTSnSrcCurrentHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOTSnSrcCurrentEntry 4 }
|
|
|
|
optIfOTSnSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on output power. If
|
|
optIfOTSnSrcCurrentOutputPower drops to this value or below,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOTSnSrcCurrentEntry 5 }
|
|
|
|
optIfOTSnSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on output power. If
|
|
optIfOTSnSrcCurrentOutputPower reaches or exceeds this value,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOTSnSrcCurrentEntry 6 }
|
|
|
|
optIfOTSnSrcCurrentInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the input."
|
|
::= { optIfOTSnSrcCurrentEntry 7 }
|
|
|
|
optIfOTSnSrcCurrentLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
|
|
DESCRIPTION
|
|
|
|
|
|
"The lowest optical power monitored at the input during the
|
|
current 15-minute interval."
|
|
::= { optIfOTSnSrcCurrentEntry 8 }
|
|
|
|
optIfOTSnSrcCurrentHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
current 15-minute interval."
|
|
::= { optIfOTSnSrcCurrentEntry 9 }
|
|
|
|
optIfOTSnSrcCurrentLowerInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on input power. If
|
|
optIfOTSnSrcCurrentInputPower drops to this value or below,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOTSnSrcCurrentEntry 10 }
|
|
|
|
optIfOTSnSrcCurrentUpperInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on input power. If
|
|
optIfOTSnSrcCurrentInputPower reaches or exceeds this value,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOTSnSrcCurrentEntry 11 }
|
|
|
|
-- OTSn source interval table
|
|
-- Contains data for previous 15-minute performance monitoring
|
|
-- intervals.
|
|
|
|
optIfOTSnSrcIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTSnSrcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of historical OTSn source performance monitoring
|
|
information."
|
|
::= { optIfOTSn 7 }
|
|
|
|
|
|
optIfOTSnSrcIntervalEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTSnSrcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OTSn source performance
|
|
monitoring information of an interface during a particular
|
|
historical interval."
|
|
INDEX { ifIndex, optIfOTSnSrcIntervalNumber }
|
|
::= { optIfOTSnSrcIntervalTable 1 }
|
|
|
|
OptIfOTSnSrcIntervalEntry ::=
|
|
SEQUENCE {
|
|
optIfOTSnSrcIntervalNumber OptIfIntervalNumber,
|
|
optIfOTSnSrcIntervalSuspectedFlag TruthValue,
|
|
optIfOTSnSrcIntervalLastOutputPower Integer32,
|
|
optIfOTSnSrcIntervalLowOutputPower Integer32,
|
|
optIfOTSnSrcIntervalHighOutputPower Integer32,
|
|
optIfOTSnSrcIntervalLastInputPower Integer32,
|
|
optIfOTSnSrcIntervalLowInputPower Integer32,
|
|
optIfOTSnSrcIntervalHighInputPower Integer32
|
|
}
|
|
|
|
optIfOTSnSrcIntervalNumber OBJECT-TYPE
|
|
SYNTAX OptIfIntervalNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies the interval."
|
|
::= { optIfOTSnSrcIntervalEntry 1 }
|
|
|
|
optIfOTSnSrcIntervalSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOTSnSrcIntervalEntry 2 }
|
|
|
|
optIfOTSnSrcIntervalLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOTSnSrcIntervalEntry 3 }
|
|
|
|
|
|
optIfOTSnSrcIntervalLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOTSnSrcIntervalEntry 4 }
|
|
|
|
optIfOTSnSrcIntervalHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOTSnSrcIntervalEntry 5 }
|
|
|
|
optIfOTSnSrcIntervalLastInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the input during the
|
|
interval."
|
|
::= { optIfOTSnSrcIntervalEntry 6 }
|
|
|
|
optIfOTSnSrcIntervalLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
interval."
|
|
::= { optIfOTSnSrcIntervalEntry 7 }
|
|
|
|
optIfOTSnSrcIntervalHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
interval."
|
|
|
|
|
|
::= { optIfOTSnSrcIntervalEntry 8 }
|
|
|
|
|
|
-- OTSn source current day table
|
|
-- Contains data for the current 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOTSnSrcCurDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTSnSrcCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OTSn source performance monitoring information for
|
|
the current 24-hour interval."
|
|
::= { optIfOTSn 8 }
|
|
|
|
optIfOTSnSrcCurDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTSnSrcCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OTSn source performance
|
|
monitoring information of an interface for the current
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOTSnSrcCurDayTable 1 }
|
|
|
|
OptIfOTSnSrcCurDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOTSnSrcCurDaySuspectedFlag TruthValue,
|
|
optIfOTSnSrcCurDayLowOutputPower Integer32,
|
|
optIfOTSnSrcCurDayHighOutputPower Integer32,
|
|
optIfOTSnSrcCurDayLowInputPower Integer32,
|
|
optIfOTSnSrcCurDayHighInputPower Integer32
|
|
}
|
|
|
|
optIfOTSnSrcCurDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOTSnSrcCurDayEntry 1 }
|
|
|
|
optIfOTSnSrcCurDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOTSnSrcCurDayEntry 2 }
|
|
|
|
optIfOTSnSrcCurDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOTSnSrcCurDayEntry 3 }
|
|
|
|
optIfOTSnSrcCurDayLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
current 24-hour interval."
|
|
::= { optIfOTSnSrcCurDayEntry 4 }
|
|
|
|
optIfOTSnSrcCurDayHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
current 24-hour interval."
|
|
::= { optIfOTSnSrcCurDayEntry 5 }
|
|
|
|
-- OTSn source previous day table
|
|
-- Contains data for the previous 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOTSnSrcPrevDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTSnSrcPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OTSn source performance monitoring information for
|
|
the previous 24-hour interval."
|
|
::= { optIfOTSn 9 }
|
|
|
|
|
|
optIfOTSnSrcPrevDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTSnSrcPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OTSn source performance
|
|
monitoring information of an interface for the previous
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOTSnSrcPrevDayTable 1 }
|
|
|
|
OptIfOTSnSrcPrevDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOTSnSrcPrevDaySuspectedFlag TruthValue,
|
|
optIfOTSnSrcPrevDayLastOutputPower Integer32,
|
|
optIfOTSnSrcPrevDayLowOutputPower Integer32,
|
|
optIfOTSnSrcPrevDayHighOutputPower Integer32,
|
|
optIfOTSnSrcPrevDayLastInputPower Integer32,
|
|
optIfOTSnSrcPrevDayLowInputPower Integer32,
|
|
optIfOTSnSrcPrevDayHighInputPower Integer32
|
|
}
|
|
|
|
optIfOTSnSrcPrevDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOTSnSrcPrevDayEntry 1 }
|
|
|
|
optIfOTSnSrcPrevDayLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSrcPrevDayEntry 2 }
|
|
|
|
optIfOTSnSrcPrevDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
|
|
|
|
::= { optIfOTSnSrcPrevDayEntry 3 }
|
|
|
|
optIfOTSnSrcPrevDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSrcPrevDayEntry 4 }
|
|
|
|
optIfOTSnSrcPrevDayLastInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSrcPrevDayEntry 5 }
|
|
|
|
optIfOTSnSrcPrevDayLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSrcPrevDayEntry 6 }
|
|
|
|
optIfOTSnSrcPrevDayHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSrcPrevDayEntry 7 }
|
|
|
|
|
|
-- the optIfOMSn group
|
|
-- This group handles the configuration and performance monitoring
|
|
-- information for OMS layers.
|
|
|
|
-- OMSn config table
|
|
|
|
optIfOMSnConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOMSnConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OMSn configuration information."
|
|
::= { optIfOMSn 1 }
|
|
|
|
optIfOMSnConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfOMSnConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OMSn configuration
|
|
information of an interface."
|
|
INDEX { ifIndex }
|
|
::= { optIfOMSnConfigTable 1 }
|
|
|
|
OptIfOMSnConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfOMSnDirectionality OptIfDirectionality,
|
|
optIfOMSnCurrentStatus BITS
|
|
}
|
|
|
|
optIfOMSnDirectionality OBJECT-TYPE
|
|
SYNTAX OptIfDirectionality
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of the entity."
|
|
::= { optIfOMSnConfigEntry 1 }
|
|
|
|
optIfOMSnCurrentStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
ssfP(0),
|
|
ssfO(1),
|
|
ssf(2),
|
|
bdiP(3),
|
|
bdiO(4),
|
|
bdi(5),
|
|
losP(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the defect condition of the entity, if any.
|
|
This object is applicable only to full capability
|
|
systems whose interface type is IaDI and for which
|
|
|
|
|
|
optIfOMSnDirectionality has the value sink(1) or
|
|
bidirectional(3)."
|
|
::= { optIfOMSnConfigEntry 2 }
|
|
|
|
-- OMSn sink current table
|
|
-- Contains data for the current 15-minute performance monitoring
|
|
-- interval.
|
|
|
|
optIfOMSnSinkCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOMSnSinkCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OMSn sink performance monitoring information for
|
|
the current 15-minute interval."
|
|
::= { optIfOMSn 2 }
|
|
|
|
optIfOMSnSinkCurrentEntry OBJECT-TYPE
|
|
SYNTAX OptIfOMSnSinkCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OMSn sink performance
|
|
monitoring information of an interface for the current
|
|
15-minute interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOMSnSinkCurrentTable 1 }
|
|
|
|
OptIfOMSnSinkCurrentEntry ::=
|
|
SEQUENCE {
|
|
optIfOMSnSinkCurrentSuspectedFlag TruthValue,
|
|
optIfOMSnSinkCurrentAggregatedInputPower Integer32,
|
|
optIfOMSnSinkCurrentLowAggregatedInputPower Integer32,
|
|
optIfOMSnSinkCurrentHighAggregatedInputPower Integer32,
|
|
optIfOMSnSinkCurrentLowerInputPowerThreshold Integer32,
|
|
optIfOMSnSinkCurrentUpperInputPowerThreshold Integer32,
|
|
optIfOMSnSinkCurrentOutputPower Integer32,
|
|
optIfOMSnSinkCurrentLowOutputPower Integer32,
|
|
optIfOMSnSinkCurrentHighOutputPower Integer32,
|
|
optIfOMSnSinkCurrentLowerOutputPowerThreshold Integer32,
|
|
optIfOMSnSinkCurrentUpperOutputPowerThreshold Integer32
|
|
}
|
|
|
|
optIfOMSnSinkCurrentSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOMSnSinkCurrentEntry 1 }
|
|
|
|
optIfOMSnSinkCurrentAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The aggregated optical power of all the DWDM input
|
|
channels."
|
|
::= { optIfOMSnSinkCurrentEntry 2 }
|
|
|
|
optIfOMSnSinkCurrentLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power of all the DWDM input
|
|
channels during the current 15-minute interval."
|
|
::= { optIfOMSnSinkCurrentEntry 3 }
|
|
|
|
optIfOMSnSinkCurrentHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power of all the DWDM input
|
|
channels during the current 15-minute interval."
|
|
::= { optIfOMSnSinkCurrentEntry 4 }
|
|
|
|
optIfOMSnSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on aggregated input power. If
|
|
optIfOMSnSinkCurrentAggregatedInputPower drops to this value
|
|
or below, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOMSnSinkCurrentEntry 5 }
|
|
|
|
optIfOMSnSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on aggregated input power. If
|
|
optIfOMSnSinkCurrentAggregatedInputPower reaches or exceeds
|
|
this value, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOMSnSinkCurrentEntry 6 }
|
|
|
|
optIfOMSnSinkCurrentOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the output."
|
|
::= { optIfOMSnSinkCurrentEntry 7 }
|
|
|
|
optIfOMSnSinkCurrentLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output
|
|
during the current 15-minute interval."
|
|
::= { optIfOMSnSinkCurrentEntry 8 }
|
|
|
|
optIfOMSnSinkCurrentHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output
|
|
during the current 15-minute interval."
|
|
::= { optIfOMSnSinkCurrentEntry 9 }
|
|
|
|
optIfOMSnSinkCurrentLowerOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on output power. If
|
|
optIfOMSnSinkCurrentOutputPower drops to this value
|
|
or below, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOMSnSinkCurrentEntry 10 }
|
|
|
|
optIfOMSnSinkCurrentUpperOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on output power. If
|
|
optIfOMSnSinkCurrentOutputPower reaches or exceeds
|
|
this value, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOMSnSinkCurrentEntry 11 }
|
|
|
|
-- OMSn sink interval table
|
|
-- Contains data for previous 15-minute performance monitoring
|
|
-- intervals.
|
|
|
|
optIfOMSnSinkIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOMSnSinkIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of historical OMSn sink performance monitoring
|
|
information."
|
|
::= { optIfOMSn 3 }
|
|
|
|
optIfOMSnSinkIntervalEntry OBJECT-TYPE
|
|
SYNTAX OptIfOMSnSinkIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OMSn sink performance
|
|
monitoring information of an interface during a particular
|
|
historical interval."
|
|
INDEX { ifIndex, optIfOMSnSinkIntervalNumber }
|
|
::= { optIfOMSnSinkIntervalTable 1 }
|
|
|
|
OptIfOMSnSinkIntervalEntry ::=
|
|
SEQUENCE {
|
|
optIfOMSnSinkIntervalNumber OptIfIntervalNumber,
|
|
optIfOMSnSinkIntervalSuspectedFlag TruthValue,
|
|
optIfOMSnSinkIntervalLastAggregatedInputPower Integer32,
|
|
optIfOMSnSinkIntervalLowAggregatedInputPower Integer32,
|
|
optIfOMSnSinkIntervalHighAggregatedInputPower Integer32,
|
|
optIfOMSnSinkIntervalLastOutputPower Integer32,
|
|
optIfOMSnSinkIntervalLowOutputPower Integer32,
|
|
optIfOMSnSinkIntervalHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOMSnSinkIntervalNumber OBJECT-TYPE
|
|
SYNTAX OptIfIntervalNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies the interval."
|
|
::= { optIfOMSnSinkIntervalEntry 1 }
|
|
|
|
optIfOMSnSinkIntervalSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOMSnSinkIntervalEntry 2 }
|
|
|
|
optIfOMSnSinkIntervalLastAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last aggregated optical power of all the DWDM input
|
|
channels during the interval."
|
|
::= { optIfOMSnSinkIntervalEntry 3 }
|
|
|
|
optIfOMSnSinkIntervalLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power of all the DWDM input
|
|
channels during the interval."
|
|
::= { optIfOMSnSinkIntervalEntry 4 }
|
|
|
|
optIfOMSnSinkIntervalHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power of all the DWDM input
|
|
channels during the interval."
|
|
::= { optIfOMSnSinkIntervalEntry 5 }
|
|
|
|
optIfOMSnSinkIntervalLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power at the output
|
|
during the interval."
|
|
::= { optIfOMSnSinkIntervalEntry 6 }
|
|
|
|
optIfOMSnSinkIntervalLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power at the output
|
|
during the interval."
|
|
::= { optIfOMSnSinkIntervalEntry 7 }
|
|
|
|
optIfOMSnSinkIntervalHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power at the output
|
|
during the interval."
|
|
::= { optIfOMSnSinkIntervalEntry 8 }
|
|
|
|
-- OMSn sink current day table
|
|
-- Contains data for the current 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOMSnSinkCurDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOMSnSinkCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OMSn sink performance monitoring information for
|
|
the current 24-hour interval."
|
|
::= { optIfOMSn 4 }
|
|
|
|
optIfOMSnSinkCurDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOMSnSinkCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OMSn sink performance
|
|
monitoring information of an interface for the current
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOMSnSinkCurDayTable 1 }
|
|
|
|
OptIfOMSnSinkCurDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOMSnSinkCurDaySuspectedFlag TruthValue,
|
|
optIfOMSnSinkCurDayLowAggregatedInputPower Integer32,
|
|
optIfOMSnSinkCurDayHighAggregatedInputPower Integer32,
|
|
optIfOMSnSinkCurDayLowOutputPower Integer32,
|
|
optIfOMSnSinkCurDayHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOMSnSinkCurDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOMSnSinkCurDayEntry 1 }
|
|
|
|
optIfOMSnSinkCurDayLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power of all the DWDM input
|
|
channels during the current 24-hour interval."
|
|
::= { optIfOMSnSinkCurDayEntry 2 }
|
|
|
|
optIfOMSnSinkCurDayHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power of all the DWDM input
|
|
channels during the current 24-hour interval."
|
|
::= { optIfOMSnSinkCurDayEntry 3 }
|
|
|
|
optIfOMSnSinkCurDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power at the output
|
|
during the current 24-hour interval."
|
|
::= { optIfOMSnSinkCurDayEntry 4 }
|
|
|
|
optIfOMSnSinkCurDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power at the output
|
|
during the current 24-hour interval."
|
|
::= { optIfOMSnSinkCurDayEntry 5 }
|
|
|
|
-- OMSn sink previous day table
|
|
-- Contains data for the previous 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOMSnSinkPrevDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOMSnSinkPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OMSn sink performance monitoring information for
|
|
the previous 24-hour interval."
|
|
::= { optIfOMSn 5 }
|
|
|
|
optIfOMSnSinkPrevDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOMSnSinkPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OMSn sink performance
|
|
monitoring information of an interface for the previous
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOMSnSinkPrevDayTable 1 }
|
|
|
|
OptIfOMSnSinkPrevDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOMSnSinkPrevDaySuspectedFlag TruthValue,
|
|
optIfOMSnSinkPrevDayLastAggregatedInputPower Integer32,
|
|
optIfOMSnSinkPrevDayLowAggregatedInputPower Integer32,
|
|
optIfOMSnSinkPrevDayHighAggregatedInputPower Integer32,
|
|
optIfOMSnSinkPrevDayLastOutputPower Integer32,
|
|
optIfOMSnSinkPrevDayLowOutputPower Integer32,
|
|
optIfOMSnSinkPrevDayHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOMSnSinkPrevDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOMSnSinkPrevDayEntry 1 }
|
|
|
|
optIfOMSnSinkPrevDayLastAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last aggregated optical power of all the DWDM input
|
|
channels during the previous 24-hour interval."
|
|
::= { optIfOMSnSinkPrevDayEntry 2 }
|
|
|
|
optIfOMSnSinkPrevDayLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power of all the DWDM input
|
|
channels during the previous 24-hour interval."
|
|
::= { optIfOMSnSinkPrevDayEntry 3 }
|
|
|
|
optIfOMSnSinkPrevDayHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power of all the DWDM input
|
|
channels during the previous 24-hour interval."
|
|
::= { optIfOMSnSinkPrevDayEntry 4 }
|
|
|
|
optIfOMSnSinkPrevDayLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power at the output
|
|
during the previous 24-hour interval."
|
|
::= { optIfOMSnSinkPrevDayEntry 5 }
|
|
|
|
optIfOMSnSinkPrevDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power at the output
|
|
during the previous 24-hour interval."
|
|
::= { optIfOMSnSinkPrevDayEntry 6 }
|
|
|
|
optIfOMSnSinkPrevDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power at the output
|
|
during the previous 24-hour interval."
|
|
::= { optIfOMSnSinkPrevDayEntry 7 }
|
|
|
|
-- OMSn source current table
|
|
-- Contains data for the current 15-minute performance monitoring
|
|
-- interval.
|
|
|
|
optIfOMSnSrcCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOMSnSrcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OMSn source performance monitoring information for
|
|
the current 15-minute interval."
|
|
::= { optIfOMSn 6 }
|
|
|
|
optIfOMSnSrcCurrentEntry OBJECT-TYPE
|
|
SYNTAX OptIfOMSnSrcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OMSn source performance
|
|
monitoring information of an interface for the current
|
|
15-minute interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOMSnSrcCurrentTable 1 }
|
|
|
|
OptIfOMSnSrcCurrentEntry ::=
|
|
SEQUENCE {
|
|
optIfOMSnSrcCurrentSuspectedFlag TruthValue,
|
|
optIfOMSnSrcCurrentOutputPower Integer32,
|
|
optIfOMSnSrcCurrentLowOutputPower Integer32,
|
|
optIfOMSnSrcCurrentHighOutputPower Integer32,
|
|
optIfOMSnSrcCurrentLowerOutputPowerThreshold Integer32,
|
|
optIfOMSnSrcCurrentUpperOutputPowerThreshold Integer32,
|
|
optIfOMSnSrcCurrentAggregatedInputPower Integer32,
|
|
optIfOMSnSrcCurrentLowAggregatedInputPower Integer32,
|
|
optIfOMSnSrcCurrentHighAggregatedInputPower Integer32,
|
|
optIfOMSnSrcCurrentLowerInputPowerThreshold Integer32,
|
|
optIfOMSnSrcCurrentUpperInputPowerThreshold Integer32
|
|
}
|
|
|
|
optIfOMSnSrcCurrentSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOMSnSrcCurrentEntry 1 }
|
|
|
|
optIfOMSnSrcCurrentOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the output."
|
|
::= { optIfOMSnSrcCurrentEntry 2 }
|
|
|
|
optIfOMSnSrcCurrentLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOMSnSrcCurrentEntry 3 }
|
|
|
|
optIfOMSnSrcCurrentHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOMSnSrcCurrentEntry 4 }
|
|
|
|
optIfOMSnSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on output power. If
|
|
optIfOMSnSrcCurrentOutputPower drops to this value or below,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOMSnSrcCurrentEntry 5 }
|
|
|
|
optIfOMSnSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on output power. If
|
|
optIfOMSnSrcCurrentOutputPower reaches or exceeds this value,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOMSnSrcCurrentEntry 6 }
|
|
|
|
optIfOMSnSrcCurrentAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The aggregated optical power at the input."
|
|
::= { optIfOMSnSrcCurrentEntry 7 }
|
|
|
|
optIfOMSnSrcCurrentLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power at the input
|
|
during the current 15-minute interval."
|
|
::= { optIfOMSnSrcCurrentEntry 8 }
|
|
|
|
optIfOMSnSrcCurrentHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power at the input
|
|
during the current 15-minute interval."
|
|
::= { optIfOMSnSrcCurrentEntry 9 }
|
|
|
|
|
|
optIfOMSnSrcCurrentLowerInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on aggregated input power. If
|
|
optIfOMSnSrcCurrentAggregatedInputPower drops to this value
|
|
or below, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOMSnSrcCurrentEntry 10 }
|
|
|
|
optIfOMSnSrcCurrentUpperInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on aggregated input power. If
|
|
optIfOMSnSrcCurrentAggregatedInputPower reaches or exceeds
|
|
this value, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOMSnSrcCurrentEntry 11 }
|
|
|
|
|
|
-- OMSn source interval table
|
|
-- Contains data for previous 15-minute performance monitoring
|
|
-- intervals.
|
|
|
|
optIfOMSnSrcIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOMSnSrcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of historical OMSn source performance monitoring
|
|
information."
|
|
::= { optIfOMSn 7 }
|
|
|
|
optIfOMSnSrcIntervalEntry OBJECT-TYPE
|
|
SYNTAX OptIfOMSnSrcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OMSn source performance
|
|
monitoring information of an interface during a particular
|
|
historical interval."
|
|
INDEX { ifIndex, optIfOMSnSrcIntervalNumber }
|
|
::= { optIfOMSnSrcIntervalTable 1 }
|
|
|
|
OptIfOMSnSrcIntervalEntry ::=
|
|
SEQUENCE {
|
|
optIfOMSnSrcIntervalNumber OptIfIntervalNumber,
|
|
optIfOMSnSrcIntervalSuspectedFlag TruthValue,
|
|
optIfOMSnSrcIntervalLastOutputPower Integer32,
|
|
optIfOMSnSrcIntervalLowOutputPower Integer32,
|
|
optIfOMSnSrcIntervalHighOutputPower Integer32,
|
|
optIfOMSnSrcIntervalLastAggregatedInputPower Integer32,
|
|
optIfOMSnSrcIntervalLowAggregatedInputPower Integer32,
|
|
optIfOMSnSrcIntervalHighAggregatedInputPower Integer32
|
|
}
|
|
|
|
optIfOMSnSrcIntervalNumber OBJECT-TYPE
|
|
SYNTAX OptIfIntervalNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies the interval."
|
|
::= { optIfOMSnSrcIntervalEntry 1 }
|
|
|
|
optIfOMSnSrcIntervalSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOMSnSrcIntervalEntry 2 }
|
|
|
|
optIfOMSnSrcIntervalLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOMSnSrcIntervalEntry 3 }
|
|
|
|
optIfOMSnSrcIntervalLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOMSnSrcIntervalEntry 4 }
|
|
|
|
optIfOMSnSrcIntervalHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOMSnSrcIntervalEntry 5 }
|
|
|
|
optIfOMSnSrcIntervalLastAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last aggregated optical power at the input
|
|
during the interval."
|
|
::= { optIfOMSnSrcIntervalEntry 6 }
|
|
|
|
optIfOMSnSrcIntervalLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power at the input
|
|
during the interval."
|
|
::= { optIfOMSnSrcIntervalEntry 7 }
|
|
|
|
optIfOMSnSrcIntervalHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power at the input
|
|
during the interval."
|
|
::= { optIfOMSnSrcIntervalEntry 8 }
|
|
|
|
-- OMSn source current day table
|
|
-- Contains data for the current 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOMSnSrcCurDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOMSnSrcCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OMSn source performance monitoring information for
|
|
the current 24-hour interval."
|
|
::= { optIfOMSn 8 }
|
|
|
|
optIfOMSnSrcCurDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOMSnSrcCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OMSn source performance
|
|
monitoring information of an interface for the current
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOMSnSrcCurDayTable 1 }
|
|
|
|
OptIfOMSnSrcCurDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOMSnSrcCurDaySuspectedFlag TruthValue,
|
|
optIfOMSnSrcCurDayLowOutputPower Integer32,
|
|
optIfOMSnSrcCurDayHighOutputPower Integer32,
|
|
optIfOMSnSrcCurDayLowAggregatedInputPower Integer32,
|
|
optIfOMSnSrcCurDayHighAggregatedInputPower Integer32
|
|
}
|
|
|
|
optIfOMSnSrcCurDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOMSnSrcCurDayEntry 1 }
|
|
|
|
optIfOMSnSrcCurDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOMSnSrcCurDayEntry 2 }
|
|
|
|
optIfOMSnSrcCurDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOMSnSrcCurDayEntry 3 }
|
|
|
|
optIfOMSnSrcCurDayLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power at the input
|
|
during the current 24-hour interval."
|
|
::= { optIfOMSnSrcCurDayEntry 4 }
|
|
|
|
optIfOMSnSrcCurDayHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power at the input
|
|
during the current 24-hour interval."
|
|
::= { optIfOMSnSrcCurDayEntry 5 }
|
|
|
|
-- OMSn source previous day table
|
|
-- Contains data for the previous 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOMSnSrcPrevDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOMSnSrcPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OMSn source performance monitoring information for
|
|
the previous 24-hour interval."
|
|
::= { optIfOMSn 9 }
|
|
|
|
optIfOMSnSrcPrevDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOMSnSrcPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OMSn source performance
|
|
monitoring information of an interface for the previous
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOMSnSrcPrevDayTable 1 }
|
|
|
|
|
|
OptIfOMSnSrcPrevDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOMSnSrcPrevDaySuspectedFlag TruthValue,
|
|
optIfOMSnSrcPrevDayLastOutputPower Integer32,
|
|
optIfOMSnSrcPrevDayLowOutputPower Integer32,
|
|
optIfOMSnSrcPrevDayHighOutputPower Integer32,
|
|
optIfOMSnSrcPrevDayLastAggregatedInputPower Integer32,
|
|
optIfOMSnSrcPrevDayLowAggregatedInputPower Integer32,
|
|
optIfOMSnSrcPrevDayHighAggregatedInputPower Integer32
|
|
}
|
|
|
|
optIfOMSnSrcPrevDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOMSnSrcPrevDayEntry 1 }
|
|
|
|
optIfOMSnSrcPrevDayLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOMSnSrcPrevDayEntry 2 }
|
|
|
|
optIfOMSnSrcPrevDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOMSnSrcPrevDayEntry 3 }
|
|
|
|
optIfOMSnSrcPrevDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOMSnSrcPrevDayEntry 4 }
|
|
|
|
optIfOMSnSrcPrevDayLastAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last aggregated optical power at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOMSnSrcPrevDayEntry 5 }
|
|
|
|
optIfOMSnSrcPrevDayLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOMSnSrcPrevDayEntry 6 }
|
|
|
|
optIfOMSnSrcPrevDayHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOMSnSrcPrevDayEntry 7 }
|
|
|
|
-- the optIfOChGroup group
|
|
-- This group handles the configuration and performance monitoring
|
|
-- information for OChGroup layers.
|
|
|
|
-- OChGroup config table
|
|
|
|
optIfOChGroupConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChGroupConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OChGroup configuration information."
|
|
::= { optIfOChGroup 1 }
|
|
|
|
optIfOChGroupConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChGroupConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OChGroup configuration
|
|
information of an interface."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChGroupConfigTable 1 }
|
|
|
|
OptIfOChGroupConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfOChGroupDirectionality OptIfDirectionality
|
|
}
|
|
|
|
optIfOChGroupDirectionality OBJECT-TYPE
|
|
SYNTAX OptIfDirectionality
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of the entity."
|
|
::= { optIfOChGroupConfigEntry 1 }
|
|
|
|
-- OChGroup sink current table
|
|
-- Contains data for the current 15-minute performance monitoring
|
|
-- interval.
|
|
|
|
optIfOChGroupSinkCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChGroupSinkCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OChGroup sink performance monitoring information for
|
|
the current 15-minute interval."
|
|
::= { optIfOChGroup 2 }
|
|
|
|
optIfOChGroupSinkCurrentEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChGroupSinkCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OChGroup sink performance
|
|
monitoring information of an interface for the current
|
|
15-minute interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChGroupSinkCurrentTable 1 }
|
|
|
|
OptIfOChGroupSinkCurrentEntry ::=
|
|
SEQUENCE {
|
|
optIfOChGroupSinkCurrentSuspectedFlag TruthValue,
|
|
optIfOChGroupSinkCurrentAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkCurrentLowAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkCurrentHighAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkCurrentLowerInputPowerThreshold Integer32,
|
|
optIfOChGroupSinkCurrentUpperInputPowerThreshold Integer32,
|
|
optIfOChGroupSinkCurrentOutputPower Integer32,
|
|
optIfOChGroupSinkCurrentLowOutputPower Integer32,
|
|
optIfOChGroupSinkCurrentHighOutputPower Integer32,
|
|
optIfOChGroupSinkCurrentLowerOutputPowerThreshold Integer32,
|
|
optIfOChGroupSinkCurrentUpperOutputPowerThreshold Integer32
|
|
}
|
|
|
|
optIfOChGroupSinkCurrentSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChGroupSinkCurrentEntry 1 }
|
|
|
|
optIfOChGroupSinkCurrentAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The aggregated optical power of all the DWDM input
|
|
channels in the OChGroup."
|
|
::= { optIfOChGroupSinkCurrentEntry 2 }
|
|
|
|
optIfOChGroupSinkCurrentLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the current 15-minute interval."
|
|
::= { optIfOChGroupSinkCurrentEntry 3 }
|
|
|
|
optIfOChGroupSinkCurrentHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the current 15-minute interval."
|
|
::= { optIfOChGroupSinkCurrentEntry 4 }
|
|
|
|
|
|
optIfOChGroupSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on aggregated input power. If
|
|
optIfOChGroupSinkCurrentAggregatedInputPower drops to this value
|
|
or below, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChGroupSinkCurrentEntry 5 }
|
|
|
|
optIfOChGroupSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on aggregated input power. If
|
|
optIfOChGroupSinkCurrentAggregatedInputPower reaches or exceeds
|
|
this value, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChGroupSinkCurrentEntry 6 }
|
|
|
|
optIfOChGroupSinkCurrentOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the output
|
|
in the OChGroup."
|
|
::= { optIfOChGroupSinkCurrentEntry 7 }
|
|
|
|
optIfOChGroupSinkCurrentLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output
|
|
in the OChGroup during the current 15-minute interval."
|
|
::= { optIfOChGroupSinkCurrentEntry 8 }
|
|
|
|
optIfOChGroupSinkCurrentHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output
|
|
in the OChGroup during the current 15-minute interval."
|
|
::= { optIfOChGroupSinkCurrentEntry 9 }
|
|
|
|
optIfOChGroupSinkCurrentLowerOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on the output power. If
|
|
optIfOChGroupSinkCurrentOutputPower drops to this value
|
|
or below, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChGroupSinkCurrentEntry 10 }
|
|
|
|
optIfOChGroupSinkCurrentUpperOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on the output power. If
|
|
optIfOChGroupSinkCurrentOutputPower reaches or exceeds
|
|
this value, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChGroupSinkCurrentEntry 11 }
|
|
|
|
-- OChGroup sink interval table
|
|
-- Contains data for previous 15-minute performance monitoring
|
|
-- intervals.
|
|
|
|
optIfOChGroupSinkIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChGroupSinkIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of historical OChGroup sink performance monitoring
|
|
information."
|
|
::= { optIfOChGroup 3 }
|
|
|
|
optIfOChGroupSinkIntervalEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChGroupSinkIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OChGroup sink performance
|
|
monitoring information of an interface during a particular
|
|
historical interval."
|
|
INDEX { ifIndex, optIfOChGroupSinkIntervalNumber }
|
|
::= { optIfOChGroupSinkIntervalTable 1 }
|
|
|
|
OptIfOChGroupSinkIntervalEntry ::=
|
|
SEQUENCE {
|
|
optIfOChGroupSinkIntervalNumber OptIfIntervalNumber,
|
|
optIfOChGroupSinkIntervalSuspectedFlag TruthValue,
|
|
optIfOChGroupSinkIntervalLastAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkIntervalLowAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkIntervalHighAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkIntervalLastOutputPower Integer32,
|
|
optIfOChGroupSinkIntervalLowOutputPower Integer32,
|
|
optIfOChGroupSinkIntervalHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOChGroupSinkIntervalNumber OBJECT-TYPE
|
|
SYNTAX OptIfIntervalNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies the interval."
|
|
::= { optIfOChGroupSinkIntervalEntry 1 }
|
|
|
|
optIfOChGroupSinkIntervalSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChGroupSinkIntervalEntry 2 }
|
|
|
|
optIfOChGroupSinkIntervalLastAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the interval."
|
|
::= { optIfOChGroupSinkIntervalEntry 3 }
|
|
|
|
optIfOChGroupSinkIntervalLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the interval."
|
|
::= { optIfOChGroupSinkIntervalEntry 4 }
|
|
|
|
optIfOChGroupSinkIntervalHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the interval."
|
|
::= { optIfOChGroupSinkIntervalEntry 5 }
|
|
|
|
optIfOChGroupSinkIntervalLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output
|
|
in the OChGroup during the interval."
|
|
::= { optIfOChGroupSinkIntervalEntry 6 }
|
|
|
|
optIfOChGroupSinkIntervalLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output
|
|
in the OChGroup during the interval."
|
|
::= { optIfOChGroupSinkIntervalEntry 7 }
|
|
|
|
optIfOChGroupSinkIntervalHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output
|
|
in the OChGroup during the interval."
|
|
::= { optIfOChGroupSinkIntervalEntry 8 }
|
|
|
|
-- OChGroup sink current day table
|
|
-- Contains data for the current 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOChGroupSinkCurDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChGroupSinkCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OChGroup sink performance monitoring information for
|
|
the current 24-hour interval."
|
|
::= { optIfOChGroup 4 }
|
|
|
|
optIfOChGroupSinkCurDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChGroupSinkCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OChGroup sink performance
|
|
monitoring information of an interface for the current
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChGroupSinkCurDayTable 1 }
|
|
|
|
OptIfOChGroupSinkCurDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOChGroupSinkCurDaySuspectedFlag TruthValue,
|
|
optIfOChGroupSinkCurDayLowAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkCurDayHighAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkCurDayLowOutputPower Integer32,
|
|
optIfOChGroupSinkCurDayHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOChGroupSinkCurDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChGroupSinkCurDayEntry 1 }
|
|
|
|
optIfOChGroupSinkCurDayLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the current 24-hour interval."
|
|
::= { optIfOChGroupSinkCurDayEntry 2 }
|
|
|
|
optIfOChGroupSinkCurDayHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the current 24-hour interval."
|
|
::= { optIfOChGroupSinkCurDayEntry 3 }
|
|
|
|
optIfOChGroupSinkCurDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output
|
|
in the OChGroup during the current 24-hour interval."
|
|
::= { optIfOChGroupSinkCurDayEntry 4 }
|
|
|
|
optIfOChGroupSinkCurDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output
|
|
in the OChGroup during the current 24-hour interval."
|
|
::= { optIfOChGroupSinkCurDayEntry 5 }
|
|
|
|
-- OChGroup sink previous day table
|
|
-- Contains data for the previous 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOChGroupSinkPrevDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChGroupSinkPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OChGroup sink performance monitoring information for
|
|
the previous 24-hour interval."
|
|
::= { optIfOChGroup 5 }
|
|
|
|
optIfOChGroupSinkPrevDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChGroupSinkPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OChGroup sink performance
|
|
monitoring information of an interface for the previous
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChGroupSinkPrevDayTable 1 }
|
|
|
|
OptIfOChGroupSinkPrevDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOChGroupSinkPrevDaySuspectedFlag TruthValue,
|
|
optIfOChGroupSinkPrevDayLastAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkPrevDayLowAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkPrevDayHighAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkPrevDayLastOutputPower Integer32,
|
|
optIfOChGroupSinkPrevDayLowOutputPower Integer32,
|
|
optIfOChGroupSinkPrevDayHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOChGroupSinkPrevDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChGroupSinkPrevDayEntry 1 }
|
|
|
|
optIfOChGroupSinkPrevDayLastAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the previous 24-hour interval."
|
|
::= { optIfOChGroupSinkPrevDayEntry 2 }
|
|
|
|
optIfOChGroupSinkPrevDayLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the previous 24-hour interval."
|
|
::= { optIfOChGroupSinkPrevDayEntry 3 }
|
|
|
|
optIfOChGroupSinkPrevDayHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the previous 24-hour interval."
|
|
::= { optIfOChGroupSinkPrevDayEntry 4 }
|
|
|
|
optIfOChGroupSinkPrevDayLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output
|
|
in the OChGroup during the previous 24-hour interval."
|
|
::= { optIfOChGroupSinkPrevDayEntry 5 }
|
|
|
|
optIfOChGroupSinkPrevDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output
|
|
in the OChGroup during the previous 24-hour interval."
|
|
::= { optIfOChGroupSinkPrevDayEntry 6 }
|
|
|
|
optIfOChGroupSinkPrevDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output
|
|
in the OChGroup during the previous 24-hour interval."
|
|
::= { optIfOChGroupSinkPrevDayEntry 7 }
|
|
|
|
-- OChGroup source current table
|
|
-- Contains data for the current 15-minute performance monitoring
|
|
-- interval.
|
|
|
|
optIfOChGroupSrcCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChGroupSrcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OChGroup source performance monitoring information for
|
|
the current 15-minute interval."
|
|
::= { optIfOChGroup 6 }
|
|
|
|
optIfOChGroupSrcCurrentEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChGroupSrcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OChGroup source performance
|
|
monitoring information of an interface for the current
|
|
15-minute interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChGroupSrcCurrentTable 1 }
|
|
|
|
OptIfOChGroupSrcCurrentEntry ::=
|
|
SEQUENCE {
|
|
optIfOChGroupSrcCurrentSuspectedFlag TruthValue,
|
|
optIfOChGroupSrcCurrentOutputPower Integer32,
|
|
optIfOChGroupSrcCurrentLowOutputPower Integer32,
|
|
optIfOChGroupSrcCurrentHighOutputPower Integer32,
|
|
optIfOChGroupSrcCurrentLowerOutputPowerThreshold Integer32,
|
|
optIfOChGroupSrcCurrentUpperOutputPowerThreshold Integer32,
|
|
optIfOChGroupSrcCurrentAggregatedInputPower Integer32,
|
|
optIfOChGroupSrcCurrentLowAggregatedInputPower Integer32,
|
|
optIfOChGroupSrcCurrentHighAggregatedInputPower Integer32,
|
|
optIfOChGroupSrcCurrentLowerInputPowerThreshold Integer32,
|
|
optIfOChGroupSrcCurrentUpperInputPowerThreshold Integer32
|
|
}
|
|
|
|
optIfOChGroupSrcCurrentSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChGroupSrcCurrentEntry 1 }
|
|
|
|
optIfOChGroupSrcCurrentOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the output."
|
|
::= { optIfOChGroupSrcCurrentEntry 2 }
|
|
|
|
optIfOChGroupSrcCurrentLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOChGroupSrcCurrentEntry 3 }
|
|
|
|
optIfOChGroupSrcCurrentHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOChGroupSrcCurrentEntry 4 }
|
|
|
|
optIfOChGroupSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on output power. If
|
|
optIfOChGroupSrcCurrentOutputPower drops to this value or below,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChGroupSrcCurrentEntry 5 }
|
|
|
|
optIfOChGroupSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on output power. If
|
|
optIfOChGroupSrcCurrentOutputPower reaches or exceeds this value,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChGroupSrcCurrentEntry 6 }
|
|
|
|
optIfOChGroupSrcCurrentAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The aggregated optical power monitored at the input."
|
|
::= { optIfOChGroupSrcCurrentEntry 7 }
|
|
|
|
optIfOChGroupSrcCurrentLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power monitored at the input
|
|
during the current 15-minute interval."
|
|
::= { optIfOChGroupSrcCurrentEntry 8 }
|
|
|
|
optIfOChGroupSrcCurrentHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power monitored at the input
|
|
during the current 15-minute interval."
|
|
::= { optIfOChGroupSrcCurrentEntry 9 }
|
|
|
|
optIfOChGroupSrcCurrentLowerInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on input power. If
|
|
optIfOChGroupSrcCurrentAggregatedInputPower drops to this value
|
|
or below, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChGroupSrcCurrentEntry 10 }
|
|
|
|
optIfOChGroupSrcCurrentUpperInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on input power. If
|
|
optIfOChGroupSrcCurrentAggregatedInputPower reaches or exceeds
|
|
this value, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChGroupSrcCurrentEntry 11 }
|
|
|
|
-- OChGroup source interval table
|
|
-- Contains data for previous 15-minute performance monitoring
|
|
-- intervals.
|
|
|
|
optIfOChGroupSrcIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChGroupSrcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of historical OChGroup source performance monitoring
|
|
information."
|
|
::= { optIfOChGroup 7 }
|
|
|
|
optIfOChGroupSrcIntervalEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChGroupSrcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OChGroup source performance
|
|
monitoring information of an interface during a particular
|
|
historical interval."
|
|
INDEX { ifIndex, optIfOChGroupSrcIntervalNumber }
|
|
::= { optIfOChGroupSrcIntervalTable 1 }
|
|
|
|
OptIfOChGroupSrcIntervalEntry ::=
|
|
SEQUENCE {
|
|
optIfOChGroupSrcIntervalNumber OptIfIntervalNumber,
|
|
optIfOChGroupSrcIntervalSuspectedFlag TruthValue,
|
|
optIfOChGroupSrcIntervalLastOutputPower Integer32,
|
|
optIfOChGroupSrcIntervalLowOutputPower Integer32,
|
|
optIfOChGroupSrcIntervalHighOutputPower Integer32,
|
|
optIfOChGroupSrcIntervalLastAggregatedInputPower Integer32,
|
|
optIfOChGroupSrcIntervalLowAggregatedInputPower Integer32,
|
|
optIfOChGroupSrcIntervalHighAggregatedInputPower Integer32
|
|
}
|
|
|
|
optIfOChGroupSrcIntervalNumber OBJECT-TYPE
|
|
SYNTAX OptIfIntervalNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies the interval."
|
|
::= { optIfOChGroupSrcIntervalEntry 1 }
|
|
|
|
optIfOChGroupSrcIntervalSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChGroupSrcIntervalEntry 2 }
|
|
|
|
optIfOChGroupSrcIntervalLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOChGroupSrcIntervalEntry 3 }
|
|
|
|
optIfOChGroupSrcIntervalLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOChGroupSrcIntervalEntry 4 }
|
|
|
|
optIfOChGroupSrcIntervalHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOChGroupSrcIntervalEntry 5 }
|
|
|
|
optIfOChGroupSrcIntervalLastAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last aggregated optical power monitored at the input
|
|
during the interval."
|
|
::= { optIfOChGroupSrcIntervalEntry 6 }
|
|
|
|
optIfOChGroupSrcIntervalLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power monitored at the input
|
|
during the interval."
|
|
::= { optIfOChGroupSrcIntervalEntry 7 }
|
|
|
|
optIfOChGroupSrcIntervalHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power monitored at the input
|
|
during the interval."
|
|
::= { optIfOChGroupSrcIntervalEntry 8 }
|
|
|
|
-- OChGroup source current day table
|
|
-- Contains data for the current 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOChGroupSrcCurDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChGroupSrcCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OChGroup source performance monitoring information for
|
|
the current 24-hour interval."
|
|
::= { optIfOChGroup 8 }
|
|
|
|
optIfOChGroupSrcCurDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChGroupSrcCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OChGroup source performance
|
|
monitoring information of an interface for the current
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChGroupSrcCurDayTable 1 }
|
|
|
|
OptIfOChGroupSrcCurDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOChGroupSrcCurDaySuspectedFlag TruthValue,
|
|
optIfOChGroupSrcCurDayLowOutputPower Integer32,
|
|
optIfOChGroupSrcCurDayHighOutputPower Integer32,
|
|
optIfOChGroupSrcCurDayLowAggregatedInputPower Integer32,
|
|
optIfOChGroupSrcCurDayHighAggregatedInputPower Integer32
|
|
}
|
|
|
|
optIfOChGroupSrcCurDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChGroupSrcCurDayEntry 1 }
|
|
|
|
optIfOChGroupSrcCurDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOChGroupSrcCurDayEntry 2 }
|
|
|
|
optIfOChGroupSrcCurDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOChGroupSrcCurDayEntry 3 }
|
|
|
|
optIfOChGroupSrcCurDayLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power monitored at the input
|
|
during the current 24-hour interval."
|
|
::= { optIfOChGroupSrcCurDayEntry 4 }
|
|
|
|
optIfOChGroupSrcCurDayHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power monitored at the input
|
|
during the current 24-hour interval."
|
|
::= { optIfOChGroupSrcCurDayEntry 5 }
|
|
|
|
-- OChGroup source previous day table
|
|
-- Contains data for the previous 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOChGroupSrcPrevDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChGroupSrcPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OChGroup source performance monitoring information for
|
|
the previous 24-hour interval."
|
|
::= { optIfOChGroup 9 }
|
|
|
|
optIfOChGroupSrcPrevDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChGroupSrcPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OChGroup source performance
|
|
monitoring information of an interface for the previous
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChGroupSrcPrevDayTable 1 }
|
|
|
|
OptIfOChGroupSrcPrevDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOChGroupSrcPrevDaySuspectedFlag TruthValue,
|
|
optIfOChGroupSrcPrevDayLastOutputPower Integer32,
|
|
optIfOChGroupSrcPrevDayLowOutputPower Integer32,
|
|
optIfOChGroupSrcPrevDayHighOutputPower Integer32,
|
|
optIfOChGroupSrcPrevDayLastAggregatedInputPower Integer32,
|
|
optIfOChGroupSrcPrevDayLowAggregatedInputPower Integer32,
|
|
optIfOChGroupSrcPrevDayHighAggregatedInputPower Integer32
|
|
}
|
|
|
|
optIfOChGroupSrcPrevDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChGroupSrcPrevDayEntry 1 }
|
|
|
|
optIfOChGroupSrcPrevDayLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOChGroupSrcPrevDayEntry 2 }
|
|
|
|
optIfOChGroupSrcPrevDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOChGroupSrcPrevDayEntry 3 }
|
|
|
|
optIfOChGroupSrcPrevDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOChGroupSrcPrevDayEntry 4 }
|
|
|
|
optIfOChGroupSrcPrevDayLastAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last aggregated optical power monitored at the input
|
|
during the previous 24-hour interval."
|
|
::= { optIfOChGroupSrcPrevDayEntry 5 }
|
|
|
|
optIfOChGroupSrcPrevDayLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power monitored at the input
|
|
during the previous 24-hour interval."
|
|
::= { optIfOChGroupSrcPrevDayEntry 6 }
|
|
|
|
optIfOChGroupSrcPrevDayHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power monitored at the input
|
|
during the previous 24-hour interval."
|
|
::= { optIfOChGroupSrcPrevDayEntry 7 }
|
|
|
|
-- the optIfOCh group
|
|
-- This group handles the configuration and
|
|
-- performance monitoring information for OCh layers.
|
|
|
|
-- OCh config table
|
|
|
|
optIfOChConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OCh configuration information."
|
|
::= { optIfOCh 1 }
|
|
|
|
optIfOChConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OCh configuration
|
|
information of an interface."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChConfigTable 1 }
|
|
|
|
OptIfOChConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfOChDirectionality OptIfDirectionality,
|
|
optIfOChCurrentStatus BITS
|
|
}
|
|
|
|
optIfOChDirectionality OBJECT-TYPE
|
|
SYNTAX OptIfDirectionality
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of the entity."
|
|
::= { optIfOChConfigEntry 1 }
|
|
|
|
optIfOChCurrentStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
losP(0),
|
|
los(1),
|
|
oci(2),
|
|
ssfP(3),
|
|
ssfO(4),
|
|
ssf(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the defect condition of the entity, if any.
|
|
This object is applicable when optIfOChDirectionality
|
|
has the value sink(1) or bidirectional(3).
|
|
In full-capability systems the bit position los(1) is not used.
|
|
In reduced-capability systems or at IrDI interfaces only
|
|
the bit positions los(1) and ssfP(3) are used."
|
|
::= { optIfOChConfigEntry 2 }
|
|
|
|
-- OCh sink current table
|
|
-- Contains data for the current 15-minute performance monitoring
|
|
-- interval.
|
|
|
|
optIfOChSinkCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChSinkCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OCh sink performance monitoring information for
|
|
the current 15-minute interval."
|
|
::= { optIfOCh 2 }
|
|
|
|
optIfOChSinkCurrentEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChSinkCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OCh sink performance
|
|
monitoring information for an interface for the current
|
|
15-minute interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChSinkCurrentTable 1 }
|
|
|
|
OptIfOChSinkCurrentEntry ::=
|
|
SEQUENCE {
|
|
optIfOChSinkCurrentSuspectedFlag TruthValue,
|
|
optIfOChSinkCurrentInputPower Integer32,
|
|
optIfOChSinkCurrentLowInputPower Integer32,
|
|
optIfOChSinkCurrentHighInputPower Integer32,
|
|
optIfOChSinkCurrentLowerInputPowerThreshold Integer32,
|
|
optIfOChSinkCurrentUpperInputPowerThreshold Integer32
|
|
}
|
|
|
|
optIfOChSinkCurrentSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChSinkCurrentEntry 1 }
|
|
|
|
optIfOChSinkCurrentInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the input."
|
|
::= { optIfOChSinkCurrentEntry 2 }
|
|
|
|
optIfOChSinkCurrentLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
current 15-minute interval."
|
|
::= { optIfOChSinkCurrentEntry 3 }
|
|
|
|
optIfOChSinkCurrentHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
current 15-minute interval."
|
|
::= { optIfOChSinkCurrentEntry 4 }
|
|
|
|
optIfOChSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on input power. If
|
|
optIfOChSinkCurrentInputPower drops to this value or below,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChSinkCurrentEntry 5 }
|
|
|
|
optIfOChSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on input power. If
|
|
optIfOChSinkCurrentInputPower reaches or exceeds this value,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChSinkCurrentEntry 6 }
|
|
|
|
-- OCh sink interval table
|
|
-- Contains data for previous 15-minute performance monitoring
|
|
-- intervals.
|
|
|
|
optIfOChSinkIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChSinkIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of historical OCh sink performance monitoring
|
|
information."
|
|
::= { optIfOCh 3 }
|
|
|
|
optIfOChSinkIntervalEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChSinkIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OCh sink performance
|
|
monitoring information of an interface during a particular
|
|
historical interval."
|
|
INDEX { ifIndex, optIfOChSinkIntervalNumber }
|
|
::= { optIfOChSinkIntervalTable 1 }
|
|
|
|
OptIfOChSinkIntervalEntry ::=
|
|
SEQUENCE {
|
|
optIfOChSinkIntervalNumber OptIfIntervalNumber,
|
|
optIfOChSinkIntervalSuspectedFlag TruthValue,
|
|
optIfOChSinkIntervalLastInputPower Integer32,
|
|
optIfOChSinkIntervalLowInputPower Integer32,
|
|
optIfOChSinkIntervalHighInputPower Integer32
|
|
}
|
|
|
|
optIfOChSinkIntervalNumber OBJECT-TYPE
|
|
SYNTAX OptIfIntervalNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies the interval."
|
|
::= { optIfOChSinkIntervalEntry 1 }
|
|
|
|
optIfOChSinkIntervalSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChSinkIntervalEntry 2 }
|
|
|
|
optIfOChSinkIntervalLastInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the input during the
|
|
interval."
|
|
::= { optIfOChSinkIntervalEntry 3 }
|
|
|
|
optIfOChSinkIntervalLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
interval."
|
|
::= { optIfOChSinkIntervalEntry 4 }
|
|
|
|
optIfOChSinkIntervalHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
interval."
|
|
::= { optIfOChSinkIntervalEntry 5 }
|
|
|
|
-- OCh sink current day table
|
|
-- Contains data for the current 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOChSinkCurDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChSinkCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OCh sink performance monitoring information for
|
|
the current 24-hour interval."
|
|
::= { optIfOCh 4 }
|
|
|
|
optIfOChSinkCurDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChSinkCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OCh sink performance
|
|
monitoring information of an interface for the current
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChSinkCurDayTable 1 }
|
|
|
|
OptIfOChSinkCurDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOChSinkCurDaySuspectedFlag TruthValue,
|
|
optIfOChSinkCurDayLowInputPower Integer32,
|
|
optIfOChSinkCurDayHighInputPower Integer32
|
|
}
|
|
|
|
optIfOChSinkCurDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChSinkCurDayEntry 1 }
|
|
|
|
optIfOChSinkCurDayLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
current 24-hour interval."
|
|
::= { optIfOChSinkCurDayEntry 2 }
|
|
|
|
optIfOChSinkCurDayHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
current 24-hour interval."
|
|
::= { optIfOChSinkCurDayEntry 3 }
|
|
|
|
-- OCh sink previous day table
|
|
-- Contains data for the previous 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOChSinkPrevDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChSinkPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OCh sink performance monitoring information for
|
|
the previous 24-hour interval."
|
|
::= { optIfOCh 5 }
|
|
|
|
optIfOChSinkPrevDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChSinkPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OCh sink performance
|
|
monitoring information of an interface for the previous
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChSinkPrevDayTable 1 }
|
|
|
|
OptIfOChSinkPrevDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOChSinkPrevDaySuspectedFlag TruthValue,
|
|
optIfOChSinkPrevDayLastInputPower Integer32,
|
|
optIfOChSinkPrevDayLowInputPower Integer32,
|
|
optIfOChSinkPrevDayHighInputPower Integer32
|
|
}
|
|
|
|
optIfOChSinkPrevDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChSinkPrevDayEntry 1 }
|
|
|
|
optIfOChSinkPrevDayLastInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOChSinkPrevDayEntry 2 }
|
|
|
|
optIfOChSinkPrevDayLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOChSinkPrevDayEntry 3 }
|
|
|
|
optIfOChSinkPrevDayHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOChSinkPrevDayEntry 4 }
|
|
|
|
-- OCh source current table
|
|
-- Contains data for the current 15-minute performance monitoring
|
|
-- interval.
|
|
|
|
optIfOChSrcCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChSrcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OCh source performance monitoring information for
|
|
the current 15-minute interval."
|
|
::= { optIfOCh 6 }
|
|
|
|
optIfOChSrcCurrentEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChSrcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OCh source performance
|
|
monitoring information of an interface for the current
|
|
15-minute interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChSrcCurrentTable 1 }
|
|
|
|
OptIfOChSrcCurrentEntry ::=
|
|
SEQUENCE {
|
|
optIfOChSrcCurrentSuspectedFlag TruthValue,
|
|
optIfOChSrcCurrentOutputPower Integer32,
|
|
optIfOChSrcCurrentLowOutputPower Integer32,
|
|
optIfOChSrcCurrentHighOutputPower Integer32,
|
|
optIfOChSrcCurrentLowerOutputPowerThreshold Integer32,
|
|
optIfOChSrcCurrentUpperOutputPowerThreshold Integer32
|
|
}
|
|
|
|
optIfOChSrcCurrentSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChSrcCurrentEntry 1 }
|
|
|
|
optIfOChSrcCurrentOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the output."
|
|
::= { optIfOChSrcCurrentEntry 2 }
|
|
|
|
optIfOChSrcCurrentLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOChSrcCurrentEntry 3 }
|
|
|
|
optIfOChSrcCurrentHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOChSrcCurrentEntry 4 }
|
|
|
|
optIfOChSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on output power. If
|
|
optIfOChSrcCurrentOutputPower drops to this value or below,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChSrcCurrentEntry 5 }
|
|
|
|
optIfOChSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on output power. If
|
|
optIfOChSrcCurrentOutputPower reaches or exceeds this value,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChSrcCurrentEntry 6 }
|
|
|
|
-- OCh source interval table
|
|
-- Contains data for previous 15-minute performance monitoring
|
|
-- intervals.
|
|
|
|
optIfOChSrcIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChSrcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of historical OCh source performance monitoring
|
|
information."
|
|
::= { optIfOCh 7 }
|
|
|
|
optIfOChSrcIntervalEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChSrcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OCh source performance
|
|
monitoring information of an interface during a particular
|
|
historical interval."
|
|
INDEX { ifIndex, optIfOChSrcIntervalNumber }
|
|
::= { optIfOChSrcIntervalTable 1 }
|
|
|
|
OptIfOChSrcIntervalEntry ::=
|
|
SEQUENCE {
|
|
optIfOChSrcIntervalNumber OptIfIntervalNumber,
|
|
optIfOChSrcIntervalSuspectedFlag TruthValue,
|
|
optIfOChSrcIntervalLastOutputPower Integer32,
|
|
optIfOChSrcIntervalLowOutputPower Integer32,
|
|
optIfOChSrcIntervalHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOChSrcIntervalNumber OBJECT-TYPE
|
|
SYNTAX OptIfIntervalNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies the interval."
|
|
::= { optIfOChSrcIntervalEntry 1 }
|
|
|
|
optIfOChSrcIntervalSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChSrcIntervalEntry 2 }
|
|
|
|
optIfOChSrcIntervalLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOChSrcIntervalEntry 3 }
|
|
|
|
optIfOChSrcIntervalLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOChSrcIntervalEntry 4 }
|
|
|
|
optIfOChSrcIntervalHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOChSrcIntervalEntry 5 }
|
|
|
|
-- OCh source current day table
|
|
-- Contains data for the current 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOChSrcCurDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChSrcCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OCh source performance monitoring information for
|
|
the current 24-hour interval."
|
|
::= { optIfOCh 8 }
|
|
|
|
optIfOChSrcCurDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChSrcCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OCh source performance
|
|
monitoring information of an interface for the current
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChSrcCurDayTable 1 }
|
|
|
|
OptIfOChSrcCurDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOChSrcCurDaySuspectedFlag TruthValue,
|
|
optIfOChSrcCurDayLowOutputPower Integer32,
|
|
optIfOChSrcCurDayHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOChSrcCurDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChSrcCurDayEntry 1 }
|
|
|
|
optIfOChSrcCurDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOChSrcCurDayEntry 2 }
|
|
|
|
optIfOChSrcCurDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOChSrcCurDayEntry 3 }
|
|
|
|
-- OCh source previous day table
|
|
-- Contains data for the previous 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOChSrcPrevDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChSrcPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OCh source performance monitoring information for
|
|
the previous 24-hour interval."
|
|
::= { optIfOCh 9 }
|
|
|
|
optIfOChSrcPrevDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChSrcPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OCh source performance
|
|
monitoring information of an interface for the previous
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChSrcPrevDayTable 1 }
|
|
|
|
OptIfOChSrcPrevDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOChSrcPrevDaySuspectedFlag TruthValue,
|
|
optIfOChSrcPrevDayLastOutputPower Integer32,
|
|
optIfOChSrcPrevDayLowOutputPower Integer32,
|
|
optIfOChSrcPrevDayHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOChSrcPrevDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChSrcPrevDayEntry 1 }
|
|
|
|
optIfOChSrcPrevDayLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOChSrcPrevDayEntry 2 }
|
|
|
|
optIfOChSrcPrevDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOChSrcPrevDayEntry 3 }
|
|
|
|
optIfOChSrcPrevDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOChSrcPrevDayEntry 4 }
|
|
|
|
-- the optIfOTUk group
|
|
-- This group handles the configuration
|
|
-- information for OTUk layers.
|
|
|
|
-- OTUk config table
|
|
|
|
optIfOTUkConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTUkConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OTUk configuration information."
|
|
::= { optIfOTUk 1 }
|
|
|
|
optIfOTUkConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTUkConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OTUk configuration
|
|
information of an interface."
|
|
INDEX { ifIndex }
|
|
::= { optIfOTUkConfigTable 1 }
|
|
|
|
OptIfOTUkConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfOTUkDirectionality OptIfDirectionality,
|
|
optIfOTUkBitRateK OptIfBitRateK,
|
|
optIfOTUkTraceIdentifierTransmitted OptIfTxTI,
|
|
optIfOTUkDAPIExpected OptIfExDAPI,
|
|
optIfOTUkSAPIExpected OptIfExSAPI,
|
|
optIfOTUkTraceIdentifierAccepted OptIfAcTI,
|
|
optIfOTUkTIMDetMode OptIfTIMDetMode,
|
|
optIfOTUkTIMActEnabled TruthValue,
|
|
optIfOTUkDEGThr OptIfDEGThr,
|
|
optIfOTUkDEGM OptIfDEGM,
|
|
optIfOTUkSinkAdaptActive TruthValue,
|
|
optIfOTUkSourceAdaptActive TruthValue,
|
|
optIfOTUkSinkFECEnabled TruthValue,
|
|
optIfOTUkCurrentStatus BITS
|
|
}
|
|
|
|
optIfOTUkDirectionality OBJECT-TYPE
|
|
SYNTAX OptIfDirectionality
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of the entity."
|
|
::= { optIfOTUkConfigEntry 1 }
|
|
|
|
optIfOTUkBitRateK OBJECT-TYPE
|
|
SYNTAX OptIfBitRateK
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the bit rate of the entity."
|
|
::= { optIfOTUkConfigEntry 2 }
|
|
|
|
optIfOTUkTraceIdentifierTransmitted OBJECT-TYPE
|
|
SYNTAX OptIfTxTI
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trace identifier transmitted.
|
|
This object is applicable when optIfOTUkDirectionality
|
|
has the value source(2) or bidirectional(3). It must not
|
|
be instantiated in rows where optIfOTUkDirectionality
|
|
has the value sink(1).
|
|
If no value is ever set by a management entity for this
|
|
object, system-specific default value will be used.
|
|
Any implementation that instantiates this object must
|
|
document the system-specific default value or how it
|
|
is derived."
|
|
::= { optIfOTUkConfigEntry 3 }
|
|
|
|
optIfOTUkDAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExDAPI
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DAPI expected by the receiver.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2).
|
|
This object has no effect when optIfOTUkTIMDetMode has
|
|
the value off(1)."
|
|
::= { optIfOTUkConfigEntry 4 }
|
|
|
|
optIfOTUkSAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExSAPI
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SAPI expected by the receiver.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2).
|
|
This object has no effect when optIfOTUkTIMDetMode has
|
|
the value off(1)."
|
|
::= { optIfOTUkConfigEntry 5 }
|
|
|
|
optIfOTUkTraceIdentifierAccepted OBJECT-TYPE
|
|
SYNTAX OptIfAcTI
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual trace identifier accepted.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2).
|
|
The value of this object is unspecified when
|
|
optIfOTUkCurrentStatus indicates a near-end defect
|
|
(i.e., ssf(3), lof(4), ais(5), lom(6)) that prevents
|
|
extraction of the trace message."
|
|
::= { optIfOTUkConfigEntry 6 }
|
|
|
|
optIfOTUkTIMDetMode OBJECT-TYPE
|
|
SYNTAX OptIfTIMDetMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the mode of the Trace Identifier Mismatch (TIM)
|
|
Detection function.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2).
|
|
The default value of this object is off(1)."
|
|
::= { optIfOTUkConfigEntry 7 }
|
|
|
|
optIfOTUkTIMActEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the Trace Identifier Mismatch (TIM)
|
|
Consequent Action function is enabled.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2).
|
|
This object has no effect when optIfOTUkTIMDetMode has
|
|
the value off(1).
|
|
The default value of this object is false(2)."
|
|
::= { optIfOTUkConfigEntry 8 }
|
|
|
|
optIfOTUkDEGThr OBJECT-TYPE
|
|
SYNTAX OptIfDEGThr
|
|
UNITS "percentage"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a performance
|
|
monitoring (PM) Second to be bad. A PM Second is declared bad if
|
|
the percentage of detected errored blocks in that second is
|
|
greater than or equal to optIfOTUkDEGThr.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2).
|
|
The default value of this object is Severely Errored Second
|
|
(SES) Estimator (See ITU-T G.7710)."
|
|
::= { optIfOTUkConfigEntry 9 }
|
|
|
|
optIfOTUkDEGM OBJECT-TYPE
|
|
SYNTAX OptIfDEGM
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a Degraded Signal
|
|
defect (dDEG). A dDEG shall be declared if optIfOTUkDEGM
|
|
consecutive bad PM Seconds are detected.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2).
|
|
The default value of this object is 7 (See ITU-T G.7710)."
|
|
::= { optIfOTUkConfigEntry 10 }
|
|
|
|
optIfOTUkSinkAdaptActive OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the sink adaptation function is activated or
|
|
not.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2).
|
|
The default value of this object is false(2)."
|
|
::= { optIfOTUkConfigEntry 11 }
|
|
|
|
optIfOTUkSourceAdaptActive OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the source adaptation function is activated or
|
|
not.
|
|
This object is only applicable to the source function, i.e.,
|
|
only when optIfOTUkDirectionality has the value source(2)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value sink(1).
|
|
The default value of this object is false(2)."
|
|
::= { optIfOTUkConfigEntry 12 }
|
|
|
|
optIfOTUkSinkFECEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If Forward Error Correction (FEC) is supported, this object
|
|
indicates whether FEC at the OTUk sink adaptation function is
|
|
enabled or not.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2).
|
|
The default value of this object is true(1)."
|
|
::= { optIfOTUkConfigEntry 13 }
|
|
|
|
optIfOTUkCurrentStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
tim(0),
|
|
deg(1),
|
|
bdi(2),
|
|
ssf(3),
|
|
lof(4),
|
|
ais(5),
|
|
lom(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the defect condition of the entity, if any.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2)."
|
|
::= { optIfOTUkConfigEntry 14 }
|
|
|
|
-- GCC0 config table
|
|
|
|
optIfGCC0ConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfGCC0ConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of GCC0 configuration information."
|
|
::= { optIfOTUk 2 }
|
|
|
|
|
|
optIfGCC0ConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfGCC0ConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains GCC0 configuration
|
|
information of an interface. Each instance must
|
|
correspond to an instance of optIfOTUkConfigEntry.
|
|
Separate source and/or sink instances may exist
|
|
for a given ifIndex value, or a single bidirectional
|
|
instance may exist, but a bidirectional instance may
|
|
not coexist with a source or sink instance.
|
|
Instances of this conceptual row persist across
|
|
agent restarts."
|
|
INDEX { ifIndex, optIfGCC0Directionality }
|
|
::= { optIfGCC0ConfigTable 1 }
|
|
|
|
OptIfGCC0ConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfGCC0Directionality OptIfDirectionality,
|
|
optIfGCC0Application SnmpAdminString,
|
|
optIfGCC0RowStatus RowStatus
|
|
}
|
|
|
|
optIfGCC0Directionality OBJECT-TYPE
|
|
SYNTAX OptIfDirectionality
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of the entity.
|
|
The values source(2) and bidirectional(3) are
|
|
not allowed if the corresponding instance of
|
|
optIfOTUkDirectionality has the value sink(1).
|
|
The values sink(1) and bidirectional(3) are
|
|
not allowed if the corresponding instance of
|
|
optIfOTUkDirectionality has the value source(2)."
|
|
::= { optIfGCC0ConfigEntry 1 }
|
|
|
|
optIfGCC0Application OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the application transported by the GCC0 entity.
|
|
Example applications are ECC, User data channel.
|
|
|
|
The value of this object may not be changed when
|
|
optIfGCC0RowStatus has the value active(1)."
|
|
::= { optIfGCC0ConfigEntry 2 }
|
|
|
|
optIfGCC0RowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This columnar object is used for creating and deleting a
|
|
conceptual row of the optIfGCC0 config table.
|
|
It is used to model the addGCC0Access and removeGCC0Access
|
|
operations of an OTUk_TTP for GCC0 access control as defined
|
|
in G.874.1. Setting RowStatus to createAndGo or createAndWait
|
|
implies addGCC0Access. Setting RowStatus to destroy implies
|
|
removeGCC0Access."
|
|
::= { optIfGCC0ConfigEntry 3 }
|
|
|
|
-- the optIfODUk group
|
|
-- This group handles the configuration information
|
|
-- for the ODUk layers.
|
|
|
|
-- ODUk config table
|
|
|
|
optIfODUkConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfODUkConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of ODUk configuration information."
|
|
::= { optIfODUk 1 }
|
|
|
|
optIfODUkConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfODUkConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains ODUk configuration
|
|
information of an interface."
|
|
INDEX { ifIndex }
|
|
::= { optIfODUkConfigTable 1 }
|
|
|
|
OptIfODUkConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfODUkDirectionality OptIfDirectionality,
|
|
optIfODUkBitRateK OptIfBitRateK,
|
|
optIfODUkTcmFieldsInUse BITS,
|
|
optIfODUkPositionSeqCurrentSize Unsigned32,
|
|
optIfODUkTtpPresent TruthValue
|
|
}
|
|
|
|
optIfODUkDirectionality OBJECT-TYPE
|
|
SYNTAX OptIfDirectionality
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of the entity."
|
|
::= { optIfODUkConfigEntry 1 }
|
|
|
|
optIfODUkBitRateK OBJECT-TYPE
|
|
SYNTAX OptIfBitRateK
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the bit rate of the entity."
|
|
::= { optIfODUkConfigEntry 2 }
|
|
|
|
optIfODUkTcmFieldsInUse OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
tcmField1(0),
|
|
tcmField2(1),
|
|
tcmField3(2),
|
|
tcmField4(3),
|
|
tcmField5(4),
|
|
tcmField6(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the TCM field(s) that are currently in use.
|
|
The positions of the bits correspond to the TCM fields.
|
|
A bit that is set to 1 means that the corresponding TCM
|
|
field is used. This object will be updated when rows are
|
|
created in or deleted from the optIfODUkTConfigTable, or
|
|
the optIfODUkTNimConfigTable."
|
|
::= { optIfODUkConfigEntry 3 }
|
|
|
|
optIfODUkPositionSeqCurrentSize OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the current size of the position
|
|
sequence (i.e., number of TCM function and/or GCC12
|
|
access that have been created in the ODUk interface).
|
|
When the value of this variable is greater than zero,
|
|
it means that one or more TCM function and/or GCC12
|
|
access have been created in the ODUk interface. In this
|
|
case, there will be as many rows in the
|
|
optIfODUkPositionSeqTable as the value of
|
|
optIfODUkPositionSeqCurrentSize corresponding to this
|
|
ODUk interface, one row for each TCM function or GCC12
|
|
access. The position of the TCM function and/or
|
|
GCC12 access within the sequence is indicated by the
|
|
optIfODUkPositionSeqPosition variable in
|
|
optIfODUkPositionSeqTable.
|
|
The optIfODUkPositionSeqTable also provides pointers
|
|
to the corresponding TCM function (optIfODUkT) and
|
|
GCC12 access (optIfGCC12) entities."
|
|
::= { optIfODUkConfigEntry 4 }
|
|
|
|
optIfODUkTtpPresent OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object has the value true(1) if the ifEntry under which
|
|
it is instantiated contains an ODUk Trail Termination Point,
|
|
i.e., is the endpoint of an ODUk path. In that case there
|
|
will be a corresponding row in the ODUk TTP config table and
|
|
it will not be possible to create corresponding rows in the
|
|
ODUk NIM config table. This object has the value false(2)
|
|
if the ifEntry under which it is instantiated contains an
|
|
intermediate ODUk Connection Termination Point. In that case
|
|
there is no corresponding row in the ODUk TTP config table,
|
|
but it will be possible to create corresponding rows in the
|
|
ODUk NIM config table. This object also affects the allowable
|
|
options in rows created in the GCC12 config table and in the
|
|
ODUkT config table, as specified in the DESCRIPTION clauses
|
|
of the columns in those tables."
|
|
::= { optIfODUkConfigEntry 5 }
|
|
|
|
-- ODUk Trail Termination Point (TTP) config table
|
|
|
|
optIfODUkTtpConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfODUkTtpConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of ODUk TTP configuration information."
|
|
::= { optIfODUk 2 }
|
|
|
|
optIfODUkTtpConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfODUkTtpConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains ODUk TTP configuration
|
|
information of an interface."
|
|
INDEX { ifIndex }
|
|
::= { optIfODUkTtpConfigTable 1 }
|
|
|
|
OptIfODUkTtpConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfODUkTtpTraceIdentifierTransmitted OptIfTxTI,
|
|
optIfODUkTtpDAPIExpected OptIfExDAPI,
|
|
optIfODUkTtpSAPIExpected OptIfExSAPI,
|
|
optIfODUkTtpTraceIdentifierAccepted OptIfAcTI,
|
|
optIfODUkTtpTIMDetMode OptIfTIMDetMode,
|
|
optIfODUkTtpTIMActEnabled TruthValue,
|
|
optIfODUkTtpDEGThr OptIfDEGThr,
|
|
optIfODUkTtpDEGM OptIfDEGM,
|
|
optIfODUkTtpCurrentStatus BITS
|
|
}
|
|
|
|
optIfODUkTtpTraceIdentifierTransmitted OBJECT-TYPE
|
|
SYNTAX OptIfTxTI
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trace identifier transmitted.
|
|
This object is applicable when optIfODUkDirectionality
|
|
has the value source(2) or bidirectional(3). It must not
|
|
be instantiated in rows where optIfODUkDirectionality
|
|
has the value sink(1).
|
|
If no value is ever set by a management entity for this
|
|
object, system-specific default value will be used.
|
|
Any implementation that instantiates this object must
|
|
document the system-specific default value or how it
|
|
is derived."
|
|
::= { optIfODUkTtpConfigEntry 1 }
|
|
|
|
optIfODUkTtpDAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExDAPI
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DAPI expected by the receiver.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfODUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfODUkDirectionality has the value source(2).
|
|
This object has no effect when optIfODUkTtpTIMDetMode has
|
|
the value off(1)."
|
|
::= { optIfODUkTtpConfigEntry 2 }
|
|
|
|
optIfODUkTtpSAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExSAPI
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SAPI expected by the receiver.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfODUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfODUkDirectionality has the value source(2).
|
|
This object has no effect when optIfODUkTtpTIMDetMode has
|
|
the value off(1)."
|
|
::= { optIfODUkTtpConfigEntry 3 }
|
|
|
|
optIfODUkTtpTraceIdentifierAccepted OBJECT-TYPE
|
|
SYNTAX OptIfAcTI
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual trace identifier accepted.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfODUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfODUkDirectionality has the value source(2).
|
|
The value of this object is unspecified when
|
|
optIfODUkTtpCurrentStatus indicates a near-end defect
|
|
(i.e., oci(0), lck(1), ssf(5)) that prevents extraction
|
|
of the trace message."
|
|
::= { optIfODUkTtpConfigEntry 4 }
|
|
|
|
optIfODUkTtpTIMDetMode OBJECT-TYPE
|
|
SYNTAX OptIfTIMDetMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the mode of the Trace Identifier Mismatch (TIM)
|
|
Detection function.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfODUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfODUkDirectionality has the value source(2).
|
|
The default value of this object is off(1)."
|
|
::= { optIfODUkTtpConfigEntry 5 }
|
|
|
|
optIfODUkTtpTIMActEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the Trace Identifier Mismatch (TIM)
|
|
Consequent Action function is enabled.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfODUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfODUkDirectionality has the value source(2).
|
|
This object has no effect when optIfODUkTtpTIMDetMode has
|
|
the value off(1).
|
|
The default value of this object is false(2)."
|
|
::= { optIfODUkTtpConfigEntry 6 }
|
|
|
|
optIfODUkTtpDEGThr OBJECT-TYPE
|
|
SYNTAX OptIfDEGThr
|
|
UNITS "percentage"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a performance
|
|
monitoring (PM) Second to be bad. A PM Second is declared bad if
|
|
the percentage of detected errored blocks in that second is
|
|
greater than or equal to optIfODUkDEGThr.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfODUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfODUkDirectionality has the value source(2).
|
|
The default value of this object is Severely Errored Second
|
|
(SES) Estimator (See ITU-T G.7710)."
|
|
::= { optIfODUkTtpConfigEntry 7 }
|
|
|
|
optIfODUkTtpDEGM OBJECT-TYPE
|
|
SYNTAX OptIfDEGM
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a Degraded Signal
|
|
defect (dDEG). A dDEG shall be declared if optIfODUkDEGM
|
|
consecutive bad PM Seconds are detected.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfODUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfODUkDirectionality has the value source(2).
|
|
The default value of this object is 7 (See ITU-T G.7710)."
|
|
::= { optIfODUkTtpConfigEntry 8 }
|
|
|
|
optIfODUkTtpCurrentStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
oci(0),
|
|
lck(1),
|
|
tim(2),
|
|
deg(3),
|
|
bdi(4),
|
|
ssf(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the defect condition of the entity, if any.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfODUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfODUkDirectionality has the value source(2)."
|
|
::= { optIfODUkTtpConfigEntry 9 }
|
|
|
|
-- ODUk Position Sequence table
|
|
|
|
optIfODUkPositionSeqTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfODUkPositionSeqEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of ODUk Position Sequence information."
|
|
::= { optIfODUk 3 }
|
|
|
|
optIfODUkPositionSeqEntry OBJECT-TYPE
|
|
SYNTAX OptIfODUkPositionSeqEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains ODUk position sequence
|
|
information of an ODUk interface. The ODUk interface
|
|
is identified by the ifIndex. Associated with each
|
|
ODUk interface there may be one of more conceptual
|
|
rows in the optIfODUkPositionSeqTable. Each row
|
|
represents a TCM or GCC12 access function within the
|
|
associated ODUk interface. Rows of the
|
|
optIfODUkPositionSeqTable table are created/deleted
|
|
as the result of the creation/deletion of the optIfODUkT
|
|
or optIfGCC12 entities."
|
|
INDEX { ifIndex, optIfODUkPositionSeqIndex }
|
|
::= { optIfODUkPositionSeqTable 1 }
|
|
|
|
OptIfODUkPositionSeqEntry ::=
|
|
SEQUENCE {
|
|
optIfODUkPositionSeqIndex Unsigned32,
|
|
optIfODUkPositionSeqPosition Unsigned32,
|
|
optIfODUkPositionSeqPointer RowPointer
|
|
}
|
|
|
|
optIfODUkPositionSeqIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies a row in the
|
|
optIfODUkPositionSeqTable Table.
|
|
Each row of the optIfODUkPositionSeqTable Table
|
|
represents a TCM or GCC12 access function within the
|
|
associated ODUk interface."
|
|
::= { optIfODUkPositionSeqEntry 1 }
|
|
|
|
optIfODUkPositionSeqPosition OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the position of the TCM or
|
|
GCC12 access function within the sequence of TCMs &
|
|
GCC12 access functions of the associated ODUk
|
|
interface. The TCM or GCC12 presented by this row is
|
|
referenced by the optIfODUkPositionSeqPointer variable."
|
|
::= { optIfODUkPositionSeqEntry 2 }
|
|
|
|
optIfODUkPositionSeqPointer OBJECT-TYPE
|
|
SYNTAX RowPointer
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies the TCM or GCC12 access function
|
|
by pointing to the corresponding optIfODUkT or optIfGCC12
|
|
entity."
|
|
::= { optIfODUkPositionSeqEntry 3 }
|
|
|
|
-- ODUk Non-intrusive monitoring (Nim) config table
|
|
|
|
optIfODUkNimConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfODUkNimConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of ODUkNim configuration information."
|
|
::= { optIfODUk 4 }
|
|
|
|
optIfODUkNimConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfODUkNimConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains ODUkNim configuration
|
|
information of an interface. Each instance must
|
|
correspond to an instance of optIfODUkConfigEntry
|
|
for which optIfODUkTtpPresent has the value false(2).
|
|
|
|
Instances of this conceptual row persist across
|
|
agent restarts, and read-create columns other
|
|
than the status column may be modified while the
|
|
row is active."
|
|
INDEX { ifIndex, optIfODUkNimDirectionality }
|
|
::= { optIfODUkNimConfigTable 1 }
|
|
|
|
OptIfODUkNimConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfODUkNimDirectionality OptIfSinkOrSource,
|
|
optIfODUkNimDAPIExpected OptIfExDAPI,
|
|
optIfODUkNimSAPIExpected OptIfExSAPI,
|
|
optIfODUkNimTraceIdentifierAccepted OptIfAcTI,
|
|
optIfODUkNimTIMDetMode OptIfTIMDetMode,
|
|
optIfODUkNimTIMActEnabled TruthValue,
|
|
optIfODUkNimDEGThr OptIfDEGThr,
|
|
optIfODUkNimDEGM OptIfDEGM,
|
|
optIfODUkNimCurrentStatus BITS,
|
|
optIfODUkNimRowStatus RowStatus
|
|
}
|
|
|
|
optIfODUkNimDirectionality OBJECT-TYPE
|
|
SYNTAX OptIfSinkOrSource
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the monitor point for the ODUk Path non-intrusive
|
|
monitoring function. The value source(2) is not allowed
|
|
if the corresponding instance of optIfODUkDirectionality
|
|
has the value sink(1), and the value sink(1) is not allowed
|
|
if the corresponding instance of optIfODUkDirectionality
|
|
has the value source(2). Either the value sink(1) or
|
|
source(2) is allowed if the corresponding instance of
|
|
optIfODUkDirectionality has the value bidirectional(3).
|
|
|
|
The value sink(1) means monitoring at the sink direction
|
|
path signal of the ODUk CTP.
|
|
|
|
The value source(2) means monitoring at the source direction
|
|
path signal of the ODUk CTP. Monitoring the source direction
|
|
of an ODUk CTP is necessary in those cases where the ODUk CTP
|
|
is at an SNCP (Subnetwork Connection Protection) end (e.g., see
|
|
Figure I.1.2/G.874.1). If one would like to get the performance
|
|
of the protected connection, one cannot use the NIM function
|
|
at both ODUk CTP sinks (before the matrix), instead one should
|
|
monitor the signal at the source ODUk CTP after the matrix."
|
|
::= { optIfODUkNimConfigEntry 1 }
|
|
|
|
optIfODUkNimDAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExDAPI
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DAPI expected by the receiver.
|
|
This object has no effect if optIfODUkNimTIMDetMode has
|
|
the value off(1) or sapi(3)."
|
|
::= { optIfODUkNimConfigEntry 2 }
|
|
|
|
optIfODUkNimSAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExSAPI
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SAPI expected by the receiver.
|
|
This object has no effect if optIfODUkNimTIMDetMode has
|
|
the value off(1) or dapi(2)."
|
|
::= { optIfODUkNimConfigEntry 3 }
|
|
|
|
optIfODUkNimTraceIdentifierAccepted OBJECT-TYPE
|
|
SYNTAX OptIfAcTI
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual trace identifier accepted. The value of
|
|
this object is unspecified if optIfODUkNimCurrentStatus
|
|
has any of the bit positions oci(0), lck(1), or ssf(5)
|
|
set or if optIfODUkNimRowStatus has any value other
|
|
than active(1)."
|
|
::= { optIfODUkNimConfigEntry 4 }
|
|
|
|
optIfODUkNimTIMDetMode OBJECT-TYPE
|
|
SYNTAX OptIfTIMDetMode
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the mode of the Trace Identifier Mismatch (TIM)
|
|
Detection function."
|
|
::= { optIfODUkNimConfigEntry 5 }
|
|
|
|
optIfODUkNimTIMActEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the Trace Identifier Mismatch (TIM)
|
|
Consequent Action function is enabled."
|
|
::= { optIfODUkNimConfigEntry 6 }
|
|
|
|
optIfODUkNimDEGThr OBJECT-TYPE
|
|
SYNTAX OptIfDEGThr
|
|
UNITS "percentage"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a performance
|
|
monitoring (PM) Second to be bad. A PM Second is declared bad
|
|
if the percentage of detected errored blocks in that second is
|
|
greater than or equal to optIfODUkNimDEGThr."
|
|
::= { optIfODUkNimConfigEntry 7 }
|
|
|
|
optIfODUkNimDEGM OBJECT-TYPE
|
|
SYNTAX OptIfDEGM
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a Degraded Signal
|
|
defect (dDEG). A dDEG shall be declared if optIfODUkNimDEGM
|
|
consecutive bad PM Seconds are detected."
|
|
::= { optIfODUkNimConfigEntry 8 }
|
|
|
|
optIfODUkNimCurrentStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
oci(0),
|
|
lck(1),
|
|
tim(2),
|
|
deg(3),
|
|
bdi(4),
|
|
ssf(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the defect condition of the entity, if
|
|
any. The value of this object is unspecified if
|
|
optIfODUkNimRowStatus has any value other than
|
|
active(1)."
|
|
::= { optIfODUkNimConfigEntry 9 }
|
|
|
|
optIfODUkNimRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This columnar object is used for creating and deleting
|
|
a conceptual row of the optIfODUkNim config table.
|
|
It is used to model the activateNim and deactivateNim
|
|
operations of an OTUk_CTP for non-intrusive monitoring
|
|
control as defined in G.874.1. Setting RowStatus to
|
|
createAndGo or createAndWait implies activateNim.
|
|
Setting RowStatus to destroy implies deactivateNim."
|
|
::= { optIfODUkNimConfigEntry 10 }
|
|
|
|
-- GCC12 config table
|
|
|
|
optIfGCC12ConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfGCC12ConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of GCC12 configuration information.
|
|
The GCC function processes the GCC overhead bytes passing
|
|
through them but leave the remainder of the ODUk overhead
|
|
and payload data alone."
|
|
::= { optIfODUk 5 }
|
|
|
|
optIfGCC12ConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfGCC12ConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains GCC12 configuration
|
|
information of an interface. Each instance must
|
|
correspond to an instance of optIfODUkConfigEntry.
|
|
Separate instances providing GCC1-only access and
|
|
GCC2-only access may exist for a given ifIndex value,
|
|
or a single instance providing GCC1 + GCC2 may exist,
|
|
but a GCC1 + GCC2 instance may not coexist with a
|
|
GCC1-only or GCC2-only instance.
|
|
|
|
Instances of this conceptual row persist across agent
|
|
restarts."
|
|
INDEX { ifIndex, optIfGCC12Codirectional, optIfGCC12GCCAccess }
|
|
::= { optIfGCC12ConfigTable 1 }
|
|
|
|
|
|
OptIfGCC12ConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfGCC12Codirectional TruthValue,
|
|
optIfGCC12GCCAccess INTEGER,
|
|
optIfGCC12GCCPassThrough TruthValue,
|
|
optIfGCC12Application SnmpAdminString,
|
|
optIfGCC12RowStatus RowStatus
|
|
}
|
|
|
|
optIfGCC12Codirectional OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of the GCC12 termination with
|
|
respect to the associated ODUk CTP. The value true(1) means
|
|
that the sink part of the GCC12 extracts COMMS data from the
|
|
signal at the input to the ODUk CTP sink and the source part
|
|
of the GCC12 inserts COMMS data into the signal at the output
|
|
of the ODUk CTP source. The value false(2) means that the
|
|
sink part of the GCC12 extracts COMMS data from the signal at
|
|
the output of the ODUk CTP source and the source part of the
|
|
GCC12 inserts COMMS data into the signal at the input of the
|
|
ODUk CTP sink. This attribute may assume either value when
|
|
the corresponding instance of optIfODUkTtpPresent has the
|
|
value false(2). When the value of the corresponding instance
|
|
of optIfODUkTtpPresent is true(1) then the only value allowed
|
|
for this attribute is true(1)."
|
|
::= { optIfGCC12ConfigEntry 1 }
|
|
|
|
optIfGCC12GCCAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
gcc1 (1),
|
|
gcc2 (2),
|
|
gcc1and2 (3)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the GCC access represented by the entity."
|
|
::= { optIfGCC12ConfigEntry 2 }
|
|
|
|
optIfGCC12GCCPassThrough OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls whether the selected GCC overhead bytes are passed
|
|
through or modified. The value true(1) means that the selected
|
|
GCC overhead bytes are passed through unmodified from the ODUk
|
|
CTP input to the ODUk CTP output. The value false(2) means that
|
|
the selected GCC overhead bytes are set to zero at the ODUk CTP
|
|
output after the extraction of the COMMS data. This object has
|
|
no effect if the corresponding instance of optIfODUkTtpPresent
|
|
has the value true(1).
|
|
|
|
The value of this object may not be changed when
|
|
optIfGCC12RowStatus has the value active(1)."
|
|
::= { optIfGCC12ConfigEntry 3 }
|
|
|
|
optIfGCC12Application OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the application transported by the GCC12 entity.
|
|
Example applications are ECC, User data channel.
|
|
|
|
The value of this object may not be changed when
|
|
optIfGCC12RowStatus has the value active(1)."
|
|
::= { optIfGCC12ConfigEntry 4 }
|
|
|
|
optIfGCC12RowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This columnar object is used for creating and deleting
|
|
a conceptual row of the optIfGCC12 config table. It is
|
|
used to model the addGCC12Access and removeGCC12Access
|
|
operations of an ODUk_CTP or ODUk_TTP for GCC12 access
|
|
control as defined in G.874.1. Setting RowStatus to
|
|
createAndGo or createAndWait implies addGCC12Access.
|
|
Setting RowStatus to destroy implies removeGCC12Access.
|
|
Successful addition/removal of the GCC12 access function
|
|
will result in updating the
|
|
optIfODUkPositionSeqCurrentSize variable and the
|
|
optIfODUkPositionSeqTable table of the associated
|
|
ODUk entry in the optIfODUkConfigTable."
|
|
::= { optIfGCC12ConfigEntry 5 }
|
|
|
|
-- the optIfODUkT group
|
|
-- This group handles the configuration information
|
|
-- for the ODUkT layers.
|
|
|
|
-- ODUkT config table
|
|
|
|
optIfODUkTConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfODUkTConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of ODUkT configuration information."
|
|
::= { optIfODUkT 1 }
|
|
|
|
optIfODUkTConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfODUkTConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains ODUkT configuration
|
|
information of an interface. Each instance must
|
|
correspond to an instance of optIfODUkConfigEntry.
|
|
Rows in this table are mutually exclusive with rows
|
|
in the ODUkT NIM config table -- in other words, this
|
|
row object may not be instantiated for a given pair
|
|
of ifIndex and TCM field values if a corresponding
|
|
instance of optIfODUkTNimConfigEntry already exists.
|
|
|
|
Instances of this conceptual row persist across agent
|
|
restarts. Except where noted otherwise, read-create
|
|
columns other than the status column may be modified
|
|
while the row is active."
|
|
INDEX { ifIndex, optIfODUkTTcmField, optIfODUkTCodirectional }
|
|
::= { optIfODUkTConfigTable 1 }
|
|
|
|
OptIfODUkTConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfODUkTTcmField Unsigned32,
|
|
optIfODUkTCodirectional TruthValue,
|
|
optIfODUkTTraceIdentifierTransmitted OptIfTxTI,
|
|
optIfODUkTDAPIExpected OptIfExDAPI,
|
|
optIfODUkTSAPIExpected OptIfExSAPI,
|
|
optIfODUkTTraceIdentifierAccepted OptIfAcTI,
|
|
optIfODUkTTIMDetMode OptIfTIMDetMode,
|
|
optIfODUkTTIMActEnabled TruthValue,
|
|
optIfODUkTDEGThr OptIfDEGThr,
|
|
optIfODUkTDEGM OptIfDEGM,
|
|
optIfODUkTSinkMode INTEGER,
|
|
optIfODUkTSinkLockSignalAdminState INTEGER,
|
|
optIfODUkTSourceLockSignalAdminState INTEGER,
|
|
optIfODUkTCurrentStatus BITS,
|
|
optIfODUkTRowStatus RowStatus
|
|
}
|
|
|
|
|
|
optIfODUkTTcmField OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..6)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the tandem connection monitoring
|
|
field of the ODUk OH. Valid values are
|
|
integers from 1 to 6."
|
|
::= { optIfODUkTConfigEntry 1 }
|
|
|
|
optIfODUkTCodirectional OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of the ODUkT termination point with
|
|
respect to the associated ODUk CTP. The value true(1) means
|
|
that the sink part of the ODUkT TP extracts TCM data from the
|
|
signal at the input to the ODUk CTP sink and the source part
|
|
of the ODUkT TP inserts TCM data into the signal at the output
|
|
of the ODUk CTP source. The value false(2) means that the
|
|
sink part of the ODUkT TP extracts TCM data from the signal at
|
|
the output of the ODUk CTP source and the source part of the
|
|
ODUkT TP inserts TCM data into the signal at the input of the
|
|
ODUk CTP sink. This attribute may assume either value when
|
|
the corresponding instance of optIfODUkTtpPresent has the
|
|
value false(2). When the value of the corresponding instance
|
|
of optIfODUkTtpPresent is true(1) then the only value allowed
|
|
for this attribute is true(1)."
|
|
::= { optIfODUkTConfigEntry 2 }
|
|
|
|
optIfODUkTTraceIdentifierTransmitted OBJECT-TYPE
|
|
SYNTAX OptIfTxTI
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trace identifier transmitted.
|
|
This object is applicable only to the following three cases.
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value false(2), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value true(1).
|
|
It must not be instantiated in rows for all other cases."
|
|
::= { optIfODUkTConfigEntry 3 }
|
|
|
|
optIfODUkTDAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExDAPI
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DAPI expected by the receiver.
|
|
This object is applicable only to the following three cases.
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases.
|
|
This object has no effect when optIfODUkTTIMDetMode has
|
|
the value off(1)."
|
|
::= { optIfODUkTConfigEntry 4 }
|
|
|
|
optIfODUkTSAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExSAPI
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SAPI expected by the receiver.
|
|
This object is applicable only to the following three cases.
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases.
|
|
This object has no effect when optIfODUkTTIMDetMode has
|
|
the value off(1)."
|
|
::= { optIfODUkTConfigEntry 5 }
|
|
|
|
optIfODUkTTraceIdentifierAccepted OBJECT-TYPE
|
|
SYNTAX OptIfAcTI
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual trace identifier accepted.
|
|
This object is applicable only to the following three cases.
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases.
|
|
The value of this object is unspecified when
|
|
optIfODUkTCurrentStatus indicates a near-end defect
|
|
(i.e., oci(0), lck(1), ssf(5)) that prevents extraction
|
|
of the trace message."
|
|
::= { optIfODUkTConfigEntry 6 }
|
|
|
|
optIfODUkTTIMDetMode OBJECT-TYPE
|
|
SYNTAX OptIfTIMDetMode
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the mode of the Trace Identifier Mismatch (TIM)
|
|
Detection function.
|
|
This object is applicable only to the following three cases.
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases.
|
|
The default value of this object is off(1)."
|
|
::= { optIfODUkTConfigEntry 7 }
|
|
|
|
optIfODUkTTIMActEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the Trace Identifier Mismatch (TIM)
|
|
Consequent Action function is enabled.
|
|
This object is applicable only to the following three cases.
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases.
|
|
This object has no effect when optIfODUkTTIMDetMode has
|
|
the value off(1).
|
|
The default value of this object is false(2)."
|
|
::= { optIfODUkTConfigEntry 8 }
|
|
|
|
optIfODUkTDEGThr OBJECT-TYPE
|
|
SYNTAX OptIfDEGThr
|
|
UNITS "percentage"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a performance
|
|
monitoring (PM) Second to be bad. A PM Second is declared bad if
|
|
the percentage of detected errored blocks in that second is
|
|
greater than or equal to optIfODUkTDEGThr.
|
|
This object is applicable only to the following three cases.
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases.
|
|
The default value of this object is Severely Errored Second
|
|
(SES) Estimator (See ITU-T G.7710)."
|
|
::= { optIfODUkTConfigEntry 9 }
|
|
|
|
optIfODUkTDEGM OBJECT-TYPE
|
|
SYNTAX OptIfDEGM
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a Degraded Signal
|
|
defect (dDEG). A dDEG shall be declared if optIfODUkTDEGM
|
|
consecutive bad PM Seconds are detected.
|
|
This object is applicable only to the following three cases.
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases.
|
|
The default value of this object is 7 (See ITU-T G.7710)."
|
|
::= { optIfODUkTConfigEntry 10 }
|
|
|
|
optIfODUkTSinkMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
operational (1),
|
|
monitor (2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable specifies the TCM mode at the entity.
|
|
The value operational(1) means that TCM Overhead (TCMOH)
|
|
processes (see ITU-T G.798) shall be
|
|
performed and consequent actions for AIS, Trail
|
|
Signal Fail (TSF), Trail Signal Degraded (TSD) shall be
|
|
initiated in case of defects.
|
|
The value monitor(2) means that TCMOH processes shall be
|
|
performed but consequent actions for AIS, Trail
|
|
Server Failure (TSF), Trail Server Degraded (TSD) shall _not_ be
|
|
initiated in case of defects.
|
|
This object is applicable only when the value of
|
|
optIfODUkTtpPresent is false(2) and also either one of the
|
|
following three cases holds:
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases."
|
|
::= { optIfODUkTConfigEntry 11 }
|
|
|
|
optIfODUkTSinkLockSignalAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
locked(1),
|
|
normal(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the capability to provision the LOCK signal, which
|
|
is one of the ODUk maintenance signals, at the ODUKT sink. When
|
|
a Tandem Connection endpoint is set to admin state locked,
|
|
it inserts the ODUk-LCK signal in the sink direction.
|
|
|
|
This object is applicable only when the value of
|
|
optIfODUkTtpPresent is false(2) and also either one of the
|
|
following three cases holds:
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases."
|
|
::= { optIfODUkTConfigEntry 12 }
|
|
|
|
optIfODUkTSourceLockSignalAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
locked(1),
|
|
normal(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the capability to provision the LOCK signal, which
|
|
is one of the ODUk maintenance signals, at the source.
|
|
When a Tandem Connection endpoint is set to admin state
|
|
locked, it inserts the ODUk-LCK signal in the source
|
|
direction.
|
|
This object is applicable only when either one of the
|
|
following three cases holds:
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value false(2), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value true(1).
|
|
It must not be instantiated in rows for all other cases."
|
|
::= { optIfODUkTConfigEntry 13 }
|
|
|
|
optIfODUkTCurrentStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
oci(0),
|
|
lck(1),
|
|
tim(2),
|
|
deg(3),
|
|
bdi(4),
|
|
ssf(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the defect condition of the entity, if any.
|
|
This object is applicable only when either one of the
|
|
following three cases holds:
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases."
|
|
::= { optIfODUkTConfigEntry 14 }
|
|
|
|
optIfODUkTRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This columnar object is used for creating and deleting a
|
|
conceptual row of the optIfODUkT config table.
|
|
It is used to model the addTCM and removeTCM operations of an
|
|
ODUk_CTP or ODUk_TTP for Tandem connection monitoring as defined
|
|
in ITU-T G.874.1.
|
|
Setting RowStatus to createAndGo or createAndWait implies addTCM.
|
|
Setting RowStatus to destroy implies removeTCM.
|
|
Successful addition/removal of TCM will result in updating the
|
|
optIfODUkTcmFieldsInUse and optIfODUkPositionSeqCurrentSize
|
|
variables and the optIfODUkPositionSeqTable table of the
|
|
associated ODUk entry in the optIfODUkConfigTable."
|
|
::= { optIfODUkTConfigEntry 15 }
|
|
|
|
-- ODUkT Non-intrusive monitoring (Nim) config table
|
|
|
|
optIfODUkTNimConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfODUkTNimConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of ODUkTNim configuration information."
|
|
::= { optIfODUkT 2 }
|
|
|
|
optIfODUkTNimConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfODUkTNimConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains ODUkTNim configuration
|
|
information of an interface. Each instance must
|
|
correspond to an instance of optIfODUkConfigEntry.
|
|
Rows in this table are mutually exclusive with rows
|
|
in the ODUkT config table -- in other words, this
|
|
row object may not be instantiated for a given pair
|
|
of ifIndex and TCM field values if a corresponding
|
|
instance of optIfODUkTConfigEntry already exists.
|
|
|
|
Instances of this conceptual row persist across
|
|
agent restarts, and read-create columns other
|
|
than the status column may be modified while the
|
|
row is active."
|
|
INDEX {ifIndex, optIfODUkTNimTcmField, optIfODUkTNimDirectionality}
|
|
::= { optIfODUkTNimConfigTable 1 }
|
|
|
|
OptIfODUkTNimConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfODUkTNimTcmField Unsigned32,
|
|
optIfODUkTNimDirectionality OptIfSinkOrSource,
|
|
optIfODUkTNimDAPIExpected OptIfExDAPI,
|
|
optIfODUkTNimSAPIExpected OptIfExSAPI,
|
|
optIfODUkTNimTraceIdentifierAccepted OptIfAcTI,
|
|
optIfODUkTNimTIMDetMode OptIfTIMDetMode,
|
|
optIfODUkTNimTIMActEnabled TruthValue,
|
|
optIfODUkTNimDEGThr OptIfDEGThr,
|
|
optIfODUkTNimDEGM OptIfDEGM,
|
|
optIfODUkTNimCurrentStatus BITS,
|
|
optIfODUkTNimRowStatus RowStatus
|
|
}
|
|
|
|
optIfODUkTNimTcmField OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..6)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the tandem connection monitoring
|
|
field of the ODUk OH on which non-intrusive monitoring
|
|
is performed. Valid values are
|
|
integers from 1 to 6."
|
|
::= { optIfODUkTNimConfigEntry 1 }
|
|
|
|
optIfODUkTNimDirectionality OBJECT-TYPE
|
|
SYNTAX OptIfSinkOrSource
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the monitor point for the ODUk TCM non-intrusive
|
|
monitoring function. The value source(2) is not allowed
|
|
if the corresponding instance of optIfODUkDirectionality
|
|
has the value sink(1), and the value sink(1) is not allowed
|
|
if the corresponding instance of optIfODUkDirectionality
|
|
has the value source(2). Either the value sink(1) or
|
|
source(2) is allowed if the corresponding instance of
|
|
optIfODUkDirectionality has the value bidirectional(3).
|
|
The value sink(1) means monitoring at the sink direction
|
|
TCM signal of the ODUk CTP.
|
|
The value source(2) means monitoring at the source direction
|
|
path signal of the ODUk CTP."
|
|
::= { optIfODUkTNimConfigEntry 2 }
|
|
|
|
optIfODUkTNimDAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExDAPI
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DAPI expected by the receiver.
|
|
This object has no effect if optIfODUkTNimTIMDetMode has
|
|
the value off(1) or sapi(3)."
|
|
::= { optIfODUkTNimConfigEntry 3 }
|
|
|
|
optIfODUkTNimSAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExSAPI
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SAPI expected by the receiver.
|
|
This object has no effect if optIfODUkTNimTIMDetMode has
|
|
the value off(1) or dapi(2)."
|
|
|
|
::= { optIfODUkTNimConfigEntry 4 }
|
|
|
|
optIfODUkTNimTraceIdentifierAccepted OBJECT-TYPE
|
|
SYNTAX OptIfAcTI
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual trace identifier accepted. The value of
|
|
this object is unspecified if optIfODUkTNimCurrentStatus
|
|
has any of the bit positions oci(0), lck(1), or ssf(5)
|
|
set or if optIfODUkTNimRowStatus has any value other
|
|
than active(1)."
|
|
::= { optIfODUkTNimConfigEntry 5 }
|
|
|
|
optIfODUkTNimTIMDetMode OBJECT-TYPE
|
|
SYNTAX OptIfTIMDetMode
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the mode of the Trace Identifier Mismatch (TIM)
|
|
Detection function."
|
|
::= { optIfODUkTNimConfigEntry 6 }
|
|
|
|
optIfODUkTNimTIMActEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the Trace Identifier Mismatch (TIM)
|
|
Consequent Action function is enabled."
|
|
::= { optIfODUkTNimConfigEntry 7 }
|
|
|
|
optIfODUkTNimDEGThr OBJECT-TYPE
|
|
SYNTAX OptIfDEGThr
|
|
UNITS "percentage"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a performance
|
|
monitoring (PM) Second to be bad. A PM Second is declared bad if
|
|
the percentage of detected errored blocks in that second is
|
|
greater than or equal to optIfODUkTNimDEGThr."
|
|
::= { optIfODUkTNimConfigEntry 8 }
|
|
|
|
optIfODUkTNimDEGM OBJECT-TYPE
|
|
SYNTAX OptIfDEGM
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a Degraded Signal
|
|
defect (dDEG). A dDEG shall be declared if optIfODUkTNimDEGM
|
|
consecutive bad PM Seconds are detected."
|
|
::= { optIfODUkTNimConfigEntry 9 }
|
|
|
|
optIfODUkTNimCurrentStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
oci(0),
|
|
lck(1),
|
|
tim(2),
|
|
deg(3),
|
|
bdi(4),
|
|
ssf(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the defect condition of the entity, if any.
|
|
The value of this object is unspecified if
|
|
optIfODUkTNimRowStatus has any value other than
|
|
active(1)."
|
|
::= { optIfODUkTNimConfigEntry 10 }
|
|
|
|
optIfODUkTNimRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This columnar object is used for creating and deleting a
|
|
conceptual row of the optIfODUkTNim config table.
|
|
It is used to model the addTCM and removeTCM operations of an
|
|
ODUk_CTP or ODUk_TTP for non-intrusive Tandem connection
|
|
monitoring as defined in ITU-T G.874.1.
|
|
Setting RowStatus to createAndGo or createAndWait implies addTCM.
|
|
Setting RowStatus to destroy implies removeTCM.
|
|
Successful addition/removal of Nim TCM will result in updating
|
|
the optIfODUkPositionSeqCurrentSize variable and the
|
|
optIfODUkPositionSeqTable table of the associated ODUk entry
|
|
in the optIfODUkConfigTable."
|
|
::= { optIfODUkTNimConfigEntry 11 }
|
|
|
|
-- units of conformance
|
|
|
|
optIfOTMnGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTMnOrder,
|
|
optIfOTMnReduced,
|
|
optIfOTMnBitRates,
|
|
optIfOTMnInterfaceType,
|
|
optIfOTMnTcmMax,
|
|
optIfOTMnOpticalReach
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of OTMn structure information objects."
|
|
::= { optIfGroups 1 }
|
|
|
|
optIfPerfMonGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfPerfMonCurrentTimeElapsed,
|
|
optIfPerfMonCurDayTimeElapsed,
|
|
optIfPerfMonIntervalNumIntervals,
|
|
optIfPerfMonIntervalNumInvalidIntervals
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of performance monitoring interval objects."
|
|
::= { optIfGroups 2 }
|
|
|
|
optIfOTSnCommonGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnDirectionality
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all OTSn interfaces."
|
|
::= { optIfGroups 3 }
|
|
|
|
optIfOTSnSourceGroupFull OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnTraceIdentifierTransmitted
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to full-functionality/IaDI OTSn
|
|
interfaces that support source functions."
|
|
::= { optIfGroups 4 }
|
|
|
|
optIfOTSnAPRStatusGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnAprStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects applicable to
|
|
OTSn interfaces that support Automatic
|
|
Power Reduction functions."
|
|
::= { optIfGroups 5 }
|
|
|
|
optIfOTSnAPRControlGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnAprControl
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects applicable to
|
|
OTSn interfaces that provide Automatic
|
|
Power Reduction control functions."
|
|
::= { optIfGroups 6 }
|
|
|
|
optIfOTSnSinkGroupBasic OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnCurrentStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all OTSn interfaces that
|
|
support sink functions."
|
|
::= { optIfGroups 7 }
|
|
|
|
optIfOTSnSinkGroupFull OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnDAPIExpected,
|
|
optIfOTSnSAPIExpected,
|
|
optIfOTSnTraceIdentifierAccepted,
|
|
optIfOTSnTIMDetMode,
|
|
optIfOTSnTIMActEnabled
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to full-functionality/IaDI OTSn
|
|
interfaces that support sink functions."
|
|
::= { optIfGroups 8 }
|
|
|
|
optIfOTSnSinkPreOtnPMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnSinkCurrentSuspectedFlag,
|
|
optIfOTSnSinkCurrentInputPower,
|
|
optIfOTSnSinkCurrentLowInputPower,
|
|
optIfOTSnSinkCurrentHighInputPower,
|
|
optIfOTSnSinkCurrentOutputPower,
|
|
optIfOTSnSinkCurrentLowOutputPower,
|
|
optIfOTSnSinkCurrentHighOutputPower,
|
|
optIfOTSnSinkIntervalSuspectedFlag,
|
|
optIfOTSnSinkIntervalLastInputPower,
|
|
optIfOTSnSinkIntervalLowInputPower,
|
|
optIfOTSnSinkIntervalHighInputPower,
|
|
optIfOTSnSinkIntervalLastOutputPower,
|
|
optIfOTSnSinkIntervalLowOutputPower,
|
|
optIfOTSnSinkIntervalHighOutputPower,
|
|
optIfOTSnSinkCurDaySuspectedFlag,
|
|
optIfOTSnSinkCurDayLowInputPower,
|
|
optIfOTSnSinkCurDayHighInputPower,
|
|
optIfOTSnSinkCurDayLowOutputPower,
|
|
optIfOTSnSinkCurDayHighOutputPower,
|
|
optIfOTSnSinkPrevDaySuspectedFlag,
|
|
optIfOTSnSinkPrevDayLastInputPower,
|
|
optIfOTSnSinkPrevDayLowInputPower,
|
|
optIfOTSnSinkPrevDayHighInputPower,
|
|
optIfOTSnSinkPrevDayLastOutputPower,
|
|
optIfOTSnSinkPrevDayLowOutputPower,
|
|
optIfOTSnSinkPrevDayHighOutputPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
objects applicable to OTSn interfaces that
|
|
support sink functions."
|
|
::= { optIfGroups 9 }
|
|
|
|
optIfOTSnSinkPreOtnPMThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnSinkCurrentLowerInputPowerThreshold,
|
|
optIfOTSnSinkCurrentUpperInputPowerThreshold,
|
|
optIfOTSnSinkCurrentLowerOutputPowerThreshold,
|
|
optIfOTSnSinkCurrentUpperOutputPowerThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
threshold objects applicable to OTSn interfaces
|
|
that support sink functions."
|
|
::= { optIfGroups 10 }
|
|
|
|
optIfOTSnSourcePreOtnPMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnSrcCurrentSuspectedFlag,
|
|
optIfOTSnSrcCurrentOutputPower,
|
|
optIfOTSnSrcCurrentLowOutputPower,
|
|
optIfOTSnSrcCurrentHighOutputPower,
|
|
optIfOTSnSrcCurrentInputPower,
|
|
optIfOTSnSrcCurrentLowInputPower,
|
|
optIfOTSnSrcCurrentHighInputPower,
|
|
optIfOTSnSrcIntervalSuspectedFlag,
|
|
optIfOTSnSrcIntervalLastOutputPower,
|
|
optIfOTSnSrcIntervalLowOutputPower,
|
|
optIfOTSnSrcIntervalHighOutputPower,
|
|
optIfOTSnSrcIntervalLastInputPower,
|
|
optIfOTSnSrcIntervalLowInputPower,
|
|
optIfOTSnSrcIntervalHighInputPower,
|
|
optIfOTSnSrcCurDaySuspectedFlag,
|
|
optIfOTSnSrcCurDayLowOutputPower,
|
|
optIfOTSnSrcCurDayHighOutputPower,
|
|
optIfOTSnSrcCurDayLowInputPower,
|
|
optIfOTSnSrcCurDayHighInputPower,
|
|
optIfOTSnSrcPrevDaySuspectedFlag,
|
|
optIfOTSnSrcPrevDayLastOutputPower,
|
|
optIfOTSnSrcPrevDayLowOutputPower,
|
|
optIfOTSnSrcPrevDayHighOutputPower,
|
|
optIfOTSnSrcPrevDayLastInputPower,
|
|
optIfOTSnSrcPrevDayLowInputPower,
|
|
optIfOTSnSrcPrevDayHighInputPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
objects applicable to OTSn interfaces that
|
|
support source functions."
|
|
::= { optIfGroups 11 }
|
|
|
|
optIfOTSnSourcePreOtnPMThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnSrcCurrentLowerOutputPowerThreshold,
|
|
optIfOTSnSrcCurrentUpperOutputPowerThreshold,
|
|
optIfOTSnSrcCurrentLowerInputPowerThreshold,
|
|
optIfOTSnSrcCurrentUpperInputPowerThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
threshold objects applicable to OTSn interfaces
|
|
that support source functions."
|
|
::= { optIfGroups 12 }
|
|
|
|
optIfOMSnCommonGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOMSnDirectionality
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all OMSn interfaces."
|
|
::= { optIfGroups 13 }
|
|
|
|
optIfOMSnSinkGroupBasic OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOMSnCurrentStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all OMSn interfaces that
|
|
support sink functions."
|
|
::= { optIfGroups 14 }
|
|
|
|
optIfOMSnSinkPreOtnPMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOMSnSinkCurrentSuspectedFlag,
|
|
optIfOMSnSinkCurrentAggregatedInputPower,
|
|
optIfOMSnSinkCurrentLowAggregatedInputPower,
|
|
optIfOMSnSinkCurrentHighAggregatedInputPower,
|
|
optIfOMSnSinkCurrentOutputPower,
|
|
optIfOMSnSinkCurrentLowOutputPower,
|
|
optIfOMSnSinkCurrentHighOutputPower,
|
|
optIfOMSnSinkIntervalSuspectedFlag,
|
|
optIfOMSnSinkIntervalLastAggregatedInputPower,
|
|
optIfOMSnSinkIntervalLowAggregatedInputPower,
|
|
optIfOMSnSinkIntervalHighAggregatedInputPower,
|
|
optIfOMSnSinkIntervalLastOutputPower,
|
|
optIfOMSnSinkIntervalLowOutputPower,
|
|
optIfOMSnSinkIntervalHighOutputPower,
|
|
optIfOMSnSinkCurDaySuspectedFlag,
|
|
optIfOMSnSinkCurDayLowAggregatedInputPower,
|
|
optIfOMSnSinkCurDayHighAggregatedInputPower,
|
|
optIfOMSnSinkCurDayLowOutputPower,
|
|
optIfOMSnSinkCurDayHighOutputPower,
|
|
optIfOMSnSinkPrevDaySuspectedFlag,
|
|
optIfOMSnSinkPrevDayLastAggregatedInputPower,
|
|
optIfOMSnSinkPrevDayLowAggregatedInputPower,
|
|
optIfOMSnSinkPrevDayHighAggregatedInputPower,
|
|
optIfOMSnSinkPrevDayLastOutputPower,
|
|
optIfOMSnSinkPrevDayLowOutputPower,
|
|
optIfOMSnSinkPrevDayHighOutputPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
objects applicable to OMSn interfaces that
|
|
support sink functions."
|
|
::= { optIfGroups 15 }
|
|
|
|
optIfOMSnSinkPreOtnPMThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOMSnSinkCurrentLowerInputPowerThreshold,
|
|
optIfOMSnSinkCurrentUpperInputPowerThreshold,
|
|
optIfOMSnSinkCurrentLowerOutputPowerThreshold,
|
|
optIfOMSnSinkCurrentUpperOutputPowerThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
threshold objects applicable to OMSn interfaces
|
|
that support sink functions."
|
|
::= { optIfGroups 16 }
|
|
|
|
optIfOMSnSourcePreOtnPMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOMSnSrcCurrentSuspectedFlag,
|
|
optIfOMSnSrcCurrentOutputPower,
|
|
optIfOMSnSrcCurrentLowOutputPower,
|
|
optIfOMSnSrcCurrentHighOutputPower,
|
|
optIfOMSnSrcCurrentAggregatedInputPower,
|
|
optIfOMSnSrcCurrentLowAggregatedInputPower,
|
|
optIfOMSnSrcCurrentHighAggregatedInputPower,
|
|
optIfOMSnSrcIntervalSuspectedFlag,
|
|
optIfOMSnSrcIntervalLastOutputPower,
|
|
optIfOMSnSrcIntervalLowOutputPower,
|
|
optIfOMSnSrcIntervalHighOutputPower,
|
|
optIfOMSnSrcIntervalLastAggregatedInputPower,
|
|
optIfOMSnSrcIntervalLowAggregatedInputPower,
|
|
optIfOMSnSrcIntervalHighAggregatedInputPower,
|
|
optIfOMSnSrcCurDaySuspectedFlag,
|
|
optIfOMSnSrcCurDayLowOutputPower,
|
|
optIfOMSnSrcCurDayHighOutputPower,
|
|
optIfOMSnSrcCurDayLowAggregatedInputPower,
|
|
optIfOMSnSrcCurDayHighAggregatedInputPower,
|
|
optIfOMSnSrcPrevDaySuspectedFlag,
|
|
optIfOMSnSrcPrevDayLastOutputPower,
|
|
optIfOMSnSrcPrevDayLowOutputPower,
|
|
optIfOMSnSrcPrevDayHighOutputPower,
|
|
optIfOMSnSrcPrevDayLastAggregatedInputPower,
|
|
optIfOMSnSrcPrevDayLowAggregatedInputPower,
|
|
optIfOMSnSrcPrevDayHighAggregatedInputPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
objects applicable to OMSn interfaces that
|
|
support source functions."
|
|
::= { optIfGroups 17 }
|
|
|
|
optIfOMSnSourcePreOtnPMThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOMSnSrcCurrentLowerOutputPowerThreshold,
|
|
optIfOMSnSrcCurrentUpperOutputPowerThreshold,
|
|
optIfOMSnSrcCurrentLowerInputPowerThreshold,
|
|
optIfOMSnSrcCurrentUpperInputPowerThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
threshold objects applicable to OMSn interfaces that
|
|
that support source functions."
|
|
::= { optIfGroups 18 }
|
|
|
|
optIfOChGroupCommonGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChGroupDirectionality
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all OChGroup interfaces."
|
|
::= { optIfGroups 19 }
|
|
|
|
optIfOChGroupSinkPreOtnPMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChGroupSinkCurrentSuspectedFlag,
|
|
optIfOChGroupSinkCurrentAggregatedInputPower,
|
|
optIfOChGroupSinkCurrentLowAggregatedInputPower,
|
|
optIfOChGroupSinkCurrentHighAggregatedInputPower,
|
|
optIfOChGroupSinkCurrentOutputPower,
|
|
optIfOChGroupSinkCurrentLowOutputPower,
|
|
optIfOChGroupSinkCurrentHighOutputPower,
|
|
optIfOChGroupSinkIntervalSuspectedFlag,
|
|
optIfOChGroupSinkIntervalLastAggregatedInputPower,
|
|
optIfOChGroupSinkIntervalLowAggregatedInputPower,
|
|
optIfOChGroupSinkIntervalHighAggregatedInputPower,
|
|
optIfOChGroupSinkIntervalLastOutputPower,
|
|
optIfOChGroupSinkIntervalLowOutputPower,
|
|
optIfOChGroupSinkIntervalHighOutputPower,
|
|
optIfOChGroupSinkCurDaySuspectedFlag,
|
|
optIfOChGroupSinkCurDayLowAggregatedInputPower,
|
|
optIfOChGroupSinkCurDayHighAggregatedInputPower,
|
|
optIfOChGroupSinkCurDayLowOutputPower,
|
|
optIfOChGroupSinkCurDayHighOutputPower,
|
|
optIfOChGroupSinkPrevDaySuspectedFlag,
|
|
optIfOChGroupSinkPrevDayLastAggregatedInputPower,
|
|
optIfOChGroupSinkPrevDayLowAggregatedInputPower,
|
|
optIfOChGroupSinkPrevDayHighAggregatedInputPower,
|
|
optIfOChGroupSinkPrevDayLastOutputPower,
|
|
optIfOChGroupSinkPrevDayLowOutputPower,
|
|
optIfOChGroupSinkPrevDayHighOutputPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
objects applicable to OChGroup interfaces that
|
|
support sink functions."
|
|
::= { optIfGroups 20 }
|
|
|
|
optIfOChGroupSinkPreOtnPMThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChGroupSinkCurrentLowerInputPowerThreshold,
|
|
optIfOChGroupSinkCurrentUpperInputPowerThreshold,
|
|
optIfOChGroupSinkCurrentLowerOutputPowerThreshold,
|
|
optIfOChGroupSinkCurrentUpperOutputPowerThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
threshold objects applicable to OChGroup interfaces
|
|
that support sink functions."
|
|
::= { optIfGroups 21 }
|
|
|
|
optIfOChGroupSourcePreOtnPMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChGroupSrcCurrentSuspectedFlag,
|
|
optIfOChGroupSrcCurrentOutputPower,
|
|
optIfOChGroupSrcCurrentLowOutputPower,
|
|
optIfOChGroupSrcCurrentHighOutputPower,
|
|
optIfOChGroupSrcCurrentAggregatedInputPower,
|
|
optIfOChGroupSrcCurrentLowAggregatedInputPower,
|
|
optIfOChGroupSrcCurrentHighAggregatedInputPower,
|
|
optIfOChGroupSrcIntervalSuspectedFlag,
|
|
optIfOChGroupSrcIntervalLastOutputPower,
|
|
optIfOChGroupSrcIntervalLowOutputPower,
|
|
optIfOChGroupSrcIntervalHighOutputPower,
|
|
optIfOChGroupSrcIntervalLastAggregatedInputPower,
|
|
optIfOChGroupSrcIntervalLowAggregatedInputPower,
|
|
optIfOChGroupSrcIntervalHighAggregatedInputPower,
|
|
optIfOChGroupSrcCurDaySuspectedFlag,
|
|
optIfOChGroupSrcCurDayLowOutputPower,
|
|
optIfOChGroupSrcCurDayHighOutputPower,
|
|
optIfOChGroupSrcCurDayLowAggregatedInputPower,
|
|
optIfOChGroupSrcCurDayHighAggregatedInputPower,
|
|
optIfOChGroupSrcPrevDaySuspectedFlag,
|
|
optIfOChGroupSrcPrevDayLastOutputPower,
|
|
optIfOChGroupSrcPrevDayLowOutputPower,
|
|
optIfOChGroupSrcPrevDayHighOutputPower,
|
|
optIfOChGroupSrcPrevDayLastAggregatedInputPower,
|
|
optIfOChGroupSrcPrevDayLowAggregatedInputPower,
|
|
optIfOChGroupSrcPrevDayHighAggregatedInputPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
objects applicable to OChGroup interfaces that
|
|
support source functions."
|
|
::= { optIfGroups 22 }
|
|
|
|
optIfOChGroupSourcePreOtnPMThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChGroupSrcCurrentLowerOutputPowerThreshold,
|
|
optIfOChGroupSrcCurrentUpperOutputPowerThreshold,
|
|
optIfOChGroupSrcCurrentLowerInputPowerThreshold,
|
|
optIfOChGroupSrcCurrentUpperInputPowerThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
threshold objects applicable to OChGroup interfaces that
|
|
that support source functions."
|
|
::= { optIfGroups 23 }
|
|
|
|
optIfOChCommonGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChDirectionality
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all OCh interfaces."
|
|
::= { optIfGroups 24 }
|
|
|
|
optIfOChSinkGroupBasic OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChCurrentStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all OCh interfaces that
|
|
support sink functions."
|
|
::= { optIfGroups 25 }
|
|
|
|
optIfOChSinkPreOtnPMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChSinkCurrentSuspectedFlag,
|
|
optIfOChSinkCurrentInputPower,
|
|
optIfOChSinkCurrentLowInputPower,
|
|
optIfOChSinkCurrentHighInputPower,
|
|
optIfOChSinkIntervalSuspectedFlag,
|
|
optIfOChSinkIntervalLastInputPower,
|
|
optIfOChSinkIntervalLowInputPower,
|
|
optIfOChSinkIntervalHighInputPower,
|
|
optIfOChSinkCurDaySuspectedFlag,
|
|
optIfOChSinkCurDayLowInputPower,
|
|
optIfOChSinkCurDayHighInputPower,
|
|
optIfOChSinkPrevDaySuspectedFlag,
|
|
optIfOChSinkPrevDayLastInputPower,
|
|
optIfOChSinkPrevDayLowInputPower,
|
|
optIfOChSinkPrevDayHighInputPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
objects applicable to OCh interfaces that
|
|
support sink functions."
|
|
::= { optIfGroups 26 }
|
|
|
|
optIfOChSinkPreOtnPMThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChSinkCurrentLowerInputPowerThreshold,
|
|
optIfOChSinkCurrentUpperInputPowerThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
threshold objects applicable to OCh interfaces
|
|
that support sink functions."
|
|
::= { optIfGroups 27 }
|
|
|
|
|
|
optIfOChSourcePreOtnPMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChSrcCurrentSuspectedFlag,
|
|
optIfOChSrcCurrentOutputPower,
|
|
optIfOChSrcCurrentLowOutputPower,
|
|
optIfOChSrcCurrentHighOutputPower,
|
|
optIfOChSrcIntervalSuspectedFlag,
|
|
optIfOChSrcIntervalLastOutputPower,
|
|
optIfOChSrcIntervalLowOutputPower,
|
|
optIfOChSrcIntervalHighOutputPower,
|
|
optIfOChSrcCurDaySuspectedFlag,
|
|
optIfOChSrcCurDayLowOutputPower,
|
|
optIfOChSrcCurDayHighOutputPower,
|
|
optIfOChSrcPrevDaySuspectedFlag,
|
|
optIfOChSrcPrevDayLastOutputPower,
|
|
optIfOChSrcPrevDayLowOutputPower,
|
|
optIfOChSrcPrevDayHighOutputPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
objects applicable to OCh interfaces that
|
|
support source functions."
|
|
::= { optIfGroups 28 }
|
|
|
|
optIfOChSourcePreOtnPMThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChSrcCurrentLowerOutputPowerThreshold,
|
|
optIfOChSrcCurrentUpperOutputPowerThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
threshold objects applicable to OCh interfaces
|
|
that support source functions."
|
|
::= { optIfGroups 29 }
|
|
|
|
optIfOTUkCommonGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTUkDirectionality,
|
|
optIfOTUkBitRateK
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all OTUk interfaces."
|
|
::= { optIfGroups 30 }
|
|
|
|
optIfOTUkSourceGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTUkTraceIdentifierTransmitted,
|
|
optIfOTUkSourceAdaptActive
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to OTUk interfaces that
|
|
support source functions."
|
|
::= { optIfGroups 31 }
|
|
|
|
optIfOTUkSinkGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTUkDAPIExpected,
|
|
optIfOTUkSAPIExpected,
|
|
optIfOTUkTraceIdentifierAccepted,
|
|
optIfOTUkTIMDetMode,
|
|
optIfOTUkTIMActEnabled,
|
|
optIfOTUkDEGThr,
|
|
optIfOTUkDEGM,
|
|
optIfOTUkSinkAdaptActive,
|
|
optIfOTUkSinkFECEnabled,
|
|
optIfOTUkCurrentStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to OTUk interfaces that
|
|
support sink functions."
|
|
::= { optIfGroups 32 }
|
|
|
|
optIfGCC0Group OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfGCC0Application,
|
|
optIfGCC0RowStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of GCC0 configuration objects."
|
|
::= { optIfGroups 33 }
|
|
|
|
optIfODUkGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfODUkDirectionality,
|
|
optIfODUkBitRateK,
|
|
optIfODUkTcmFieldsInUse,
|
|
optIfODUkPositionSeqCurrentSize,
|
|
optIfODUkPositionSeqPosition,
|
|
optIfODUkPositionSeqPointer,
|
|
optIfODUkTtpPresent
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all ODUk interfaces."
|
|
::= { optIfGroups 34 }
|
|
|
|
optIfODUkTtpSourceGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfODUkTtpTraceIdentifierTransmitted
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all interfaces that support
|
|
ODUk trail termination source functions."
|
|
::= { optIfGroups 35 }
|
|
|
|
optIfODUkTtpSinkGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfODUkTtpDAPIExpected,
|
|
optIfODUkTtpSAPIExpected,
|
|
optIfODUkTtpTraceIdentifierAccepted,
|
|
optIfODUkTtpTIMDetMode,
|
|
optIfODUkTtpTIMActEnabled,
|
|
optIfODUkTtpDEGThr,
|
|
optIfODUkTtpDEGM,
|
|
optIfODUkTtpCurrentStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of ODUk configuration objects
|
|
applicable to all interfaces that support
|
|
ODUk trail termination sink functions."
|
|
::= { optIfGroups 36 }
|
|
|
|
optIfODUkNimGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfODUkNimDAPIExpected,
|
|
optIfODUkNimSAPIExpected,
|
|
optIfODUkNimTraceIdentifierAccepted,
|
|
optIfODUkNimTIMDetMode,
|
|
optIfODUkNimTIMActEnabled,
|
|
optIfODUkNimDEGThr,
|
|
optIfODUkNimDEGM,
|
|
optIfODUkNimCurrentStatus,
|
|
optIfODUkNimRowStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of ODUk Nim configuration objects."
|
|
::= { optIfGroups 37 }
|
|
|
|
optIfGCC12Group OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfGCC12GCCPassThrough,
|
|
optIfGCC12Application,
|
|
optIfGCC12RowStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of GCC12 configuration objects."
|
|
::= { optIfGroups 38 }
|
|
|
|
optIfODUkTCommonGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfODUkTRowStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all ODUkT instances."
|
|
::= { optIfGroups 39 }
|
|
|
|
optIfODUkTSourceGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfODUkTTraceIdentifierTransmitted,
|
|
optIfODUkTSourceLockSignalAdminState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all ODUkT instances
|
|
that provide source functions."
|
|
::= { optIfGroups 40 }
|
|
|
|
optIfODUkTSinkGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfODUkTDAPIExpected,
|
|
optIfODUkTSAPIExpected,
|
|
optIfODUkTTraceIdentifierAccepted,
|
|
optIfODUkTTIMDetMode,
|
|
optIfODUkTTIMActEnabled,
|
|
optIfODUkTDEGThr,
|
|
optIfODUkTDEGM,
|
|
optIfODUkTCurrentStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all ODUkT instances
|
|
that provide sink functions."
|
|
::= { optIfGroups 41 }
|
|
|
|
optIfODUkTSinkGroupCtp OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfODUkTSinkMode,
|
|
optIfODUkTSinkLockSignalAdminState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to ODUkT instances not
|
|
colocated with an ODUk TTP that
|
|
provide sink functions."
|
|
::= { optIfGroups 42 }
|
|
|
|
optIfODUkTNimGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfODUkTNimDAPIExpected,
|
|
optIfODUkTNimSAPIExpected,
|
|
optIfODUkTNimTraceIdentifierAccepted,
|
|
optIfODUkTNimTIMDetMode,
|
|
optIfODUkTNimTIMActEnabled,
|
|
optIfODUkTNimDEGThr,
|
|
optIfODUkTNimDEGM,
|
|
optIfODUkTNimCurrentStatus,
|
|
optIfODUkTNimRowStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of ODUkT Nim configuration objects."
|
|
::= { optIfGroups 43 }
|
|
|
|
|
|
END
|
|
|