-- Alarm MIB
|
|
-- *****************************************************************
|
|
|
|
SL-ALARM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
NOTIFICATION-TYPE FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, DisplayString,
|
|
TruthValue, TimeStamp FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP,
|
|
NOTIFICATION-GROUP FROM SNMPv2-CONF
|
|
InterfaceIndex FROM IF-MIB
|
|
PerfCurrentCount, PerfIntervalCount,
|
|
PerfTotalCount FROM PerfHist-TC-MIB
|
|
slMain FROM SL-MAIN-MIB;
|
|
|
|
slAlarmMib MODULE-IDENTITY
|
|
LAST-UPDATED "0008280000Z"
|
|
ORGANIZATION "PacketLight Networks Ltd."
|
|
CONTACT-INFO
|
|
"Omri_Viner@PacketLight.com"
|
|
DESCRIPTION
|
|
"This MIB module describes the ALARMS."
|
|
::= { slMain 20 }
|
|
|
|
SlAlarmType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Alarms Types."
|
|
SYNTAX INTEGER {
|
|
-- SONET/SDH alarms
|
|
losSonetAlarm(1), -- Loss Of Signal (S)
|
|
lofSonetAlarm(2), -- Loss Of Frame (S)
|
|
lopSonetAlarm(3), -- Loss Of Pointer (P)
|
|
aisLineSonetAlarm(4), -- Alarm Indication Signal (L)
|
|
rfiLineSonetAlarm(5), -- Remote Failure Indication (L)
|
|
uneqSonetAlarm(6), -- Unequipped (P)
|
|
timLine(7), -- Trace Indication Mismatch (S)
|
|
slm(8), -- Signal Label Mismatch (P) - Defect
|
|
sd(9), -- Signal Degrade (SDH only)
|
|
sf(10), -- Signal Fail (SDH only)
|
|
hwfail(11), -- HW Fail
|
|
aisPathSonetAlarm(12), -- Alarm Indication Signal (P)
|
|
rfiPathSonetAlarm(13), -- Remote Failure Indication (P)
|
|
timPath(14), -- Trace Indication Mismatch (P)
|
|
uplinkTransmitMismatch(15), -- Transceiver mismatch or removed (deprecated)
|
|
uplinkClockSourceLol(16), -- Clock Source Loss of lock
|
|
aisVtSonetAlarm(21), -- Alarm Indication Signal (V)
|
|
lopVtSonetAlarm(22), -- Loss Of Pointer (V)
|
|
rfiVtSonetAlarm(23), -- Remote Failure Indication (V)
|
|
timVt(24), -- Trace Indication Mismatch (V)
|
|
slmVt(25), -- Signal Label Mismatch (V)
|
|
uneqVtSonetAlarm(26), -- Unequipped (V)
|
|
lomVt(27), -- Loss of Multiframe (V)
|
|
|
|
-- GFP/VCG alarms
|
|
vcgFarLossClientSignal(101),-- Far-end Loss of Client Signal
|
|
vcgFarLossClientSync(102), -- Far-end Loss of Client Sync
|
|
vcgLossAlignment(103), -- VCG Loss of Alignment
|
|
vcgLossMultiframe(104), -- VCG Loss of Multiframe
|
|
vcgLossSequence(105), -- VCG Loss of Sequence
|
|
vcgGfpLossSync(106), -- GFP framer Loss of Sync
|
|
vcgFarGfpLossSync(107), -- Far-end GFP Loss of Sync
|
|
vcgBadGidMember(108), -- Bad GID of a VCAT member
|
|
|
|
-- Provisioning alarms
|
|
provUnequipped(151), -- Unprovisioned service
|
|
provMismatch(152), -- Mismatch provisioning
|
|
|
|
-- Ethernet alarms
|
|
ethConfigTransmitFault(201),-- Optical GbE transceiver transmit fault (deprecated)
|
|
ethConfigLossOfSignal(202), -- Optical GbE transceiver signal detect failed
|
|
ethConfigLinkFail(203), -- Mac Layer Link failed
|
|
ethConfigPcsLossSync(204), -- PCS coding loss of sync
|
|
|
|
-- FC alarms
|
|
fcBxPortTransmitFault(301), -- Transceiver transmit fault (deprecated)
|
|
fcBxPortLossOfSignal(302), -- Transceiver signal detect failed
|
|
fcBxPortNoLink(303), -- No link established yet.
|
|
fcBxPortLossOfSync(304), -- Loss of sync
|
|
fcBxPortTransmitMismatch(306), -- Transceiver mismatch or removed (deprecated)
|
|
fcBxPortPcsLossSync(307), -- PCS coding loss of sync
|
|
|
|
fcipLinkNoLink(311), -- No link established yet.
|
|
fcipLinkLossOfSync(312), -- Loss of sync
|
|
fcipSntpFailure(313), -- SNTP failure
|
|
fcipIpsecFailure(314), -- IPSec failure
|
|
fcipFarLossOfClient(315), -- The Far-End lost the FC link
|
|
|
|
-- Escon alarms
|
|
esconPortTransmitFault(351), -- Transceiver transmit fault (deprecated)
|
|
esconPortLossOfSignal(352), -- Transceiver signal detect failed
|
|
esconPortNoLink(353), -- No link established yet.
|
|
esconPortLossOfSync(354), -- Loss of sync
|
|
|
|
-- EDFA alarms
|
|
edfaPumpTemperuture(401), -- Pump temperatur is out-of-bound
|
|
edfaHwFail(403), -- Pump HW failure
|
|
edfaRvcSignalDetect(404), -- Loss of input signal
|
|
edfaRcvPower(406), -- Rx Power is out-of-bound
|
|
edfaTemprature(407), -- Edfa temperature is out-of-bound
|
|
edfaEyeSafty(408), -- Eye safety alarm (available only in eye-safety mode)
|
|
edafGainFlatness(409), -- Gain flatness alarm
|
|
edfaXmtPower(410), -- Tx Power is out-of-bound
|
|
edfaGain(411), -- Edfa Gain is out-of-bound
|
|
edfaEol(412), -- Pump End Of Life
|
|
|
|
-- Muxponder alarms
|
|
muxAisPath(451) , -- Muxponder AIS
|
|
muxLof(452), -- Muxponder LOF
|
|
muxRdi(453), -- Muxponder RDI
|
|
muxInbandFail(454), -- Muxponder Inband Fail
|
|
muxTempLicense(455), -- Muxponder Temporary Licensed
|
|
muxNoLicense(456), -- Muxponder Not Licensed
|
|
|
|
-- Optical Switch alarms
|
|
oswHwFail(470), -- The optical switch is defined in seep but not exist
|
|
oswLossOfSignal(471), -- LOS is detected on the port of the optical switch
|
|
oswEdfaLossProp(472),
|
|
|
|
-- Port alarms
|
|
loopback(501), -- The port is in loopback
|
|
apsForceActive(502), -- Force Switch is active on this port
|
|
apsManualActive(503), -- Manual Switch is active on this port
|
|
|
|
-- CLU alarms
|
|
cluHoldoverState(602), -- Clu is switched to holdover
|
|
cluFreerunState(603), -- Clu is in free run state
|
|
cluBelowLevel(604), -- Clock is below internal level
|
|
cluFail(606), -- Clock fail
|
|
cluJittered(608), -- Clock jittered
|
|
|
|
-- WSS alarms
|
|
channelLowDegrade(621), -- OCM Power Level Parameter 2
|
|
channelHighDegrade(622), -- OCM Power Level Parameter 3
|
|
channelLowFail(623), -- OCM Power Level Parameter 4
|
|
channelHighFail(624), -- OCM Power Level Parameter 5
|
|
unequalizedOuputPower(625), -- Failed to equalize channels output power
|
|
|
|
-- SFP Alarms
|
|
sfpTransmitFault(701), -- sfp hardware problem
|
|
sfpRemoved(702), -- spf is either removed or failed
|
|
sfpMuxWlMismatch(703), -- wl of the sfp does not match the wls of the mux
|
|
sfpBitRateMismatch(704), -- the sfp bit rate does not match the implied port rate
|
|
sfpLossOfLock(705), -- retimer problem
|
|
sfpSfpWlMismatch(706), -- two sfps with the same wave length in
|
|
sfpLossOfLight(707), -- no signnal detection
|
|
sfpLaserEndOfLife(708), -- laser end of life indication
|
|
sfpMuxSpacingMismatch(709), -- spacing of the sfp does not match the spacing of the mux
|
|
sfpHardwareFault(710), -- wrong sfp crc
|
|
sfpBlocked(711), -- the sfp is blocked
|
|
sfpLossPropagation(712), -- shut laser due to a problem with the mate sfp
|
|
sfpUnknownType(713), -- unknown sfp type warning - doesn't shut the laser
|
|
|
|
sfpHighTemp(720), -- internal temperature exceeds high alarm level.
|
|
sfpLowTemp(721), -- internal temperature is below low alarm level.
|
|
sfpHighTxPower(726), -- TX output power exceeds high alarm level.
|
|
sfpLowTxPower(727), -- TX output power is below low alarm level.
|
|
sfpHighRxPower(728), -- Received Power exceeds high alarm level.
|
|
sfpLowRxPower(729), -- Received Power is below low alarm level.
|
|
sfpHighLaserTemp(730), -- (15xy) laser TEC current exceeds high alarm level.
|
|
sfpLowLaserTemp(731), -- (15xy) laser TEC current exceeds low alarm level.
|
|
sfpHighLaserWl(732), -- (15xy) laser wavelength exceeds high alarm level.
|
|
sfpLowLaserWl(733), -- (15xy) laser wavelength is below low alarm level.
|
|
|
|
-- XFP Alarms
|
|
xfpTxNR(734),
|
|
xfpTxCdrNotLocked(735),
|
|
xfpRxNR(736),
|
|
xfpRxCdrNotLocked(737),
|
|
|
|
-- OTN Alarms
|
|
otnFecExc(750), -- FEC-EXC Trail Excessive Errors (Early FEC) > 10-4
|
|
otnFecDeg(751), -- FEC-DEG Trail Degraded Errors (Early FEC) > 10-8
|
|
otnOtuDeg(752), -- S-DEG Section- Degraded Performance. Based on SM BIP
|
|
otnOduDeg(753), -- P-DEG Path- Degraded Performance. Based on PM BIP
|
|
otnLos(754), -- LOS Loss of Signal
|
|
otnLof(755), -- LOF Loss of Frame. OOF present for at least 3ms
|
|
otnLom(756), -- LOM Loss of Multiframe; OOM present for at least 3ms
|
|
otuAis(757), -- S-AIS Section-Alarm Indication Signal
|
|
otuBdi(758), -- S-BDI Section-Backward Defect Indicator
|
|
otuTtim(759), -- S-TTIM Section-Trail Trace Identifier Mismatch (SAPI/DAPI)
|
|
oduAis(780), -- P-AIS Path-Alarm Indication Signal
|
|
oduOci(781), -- P-OCI Path-Open Connection indicator
|
|
oduLck(782), -- P-LCK Path-Locked. Path Locked active
|
|
oduBdi(783), -- P-BDI Path-Backward Error indicator.
|
|
oduTtim(784), -- P-TTIM Path-Trail Trace Identifier Mismatch (SAPI/DAPI)
|
|
oduPtm(785), -- P-PTM Path Payload Type Mismatch
|
|
|
|
-- NE alarms
|
|
entityRemoved(801), -- Card is removed from the slot
|
|
entityClockFail(803), -- Clock Failure
|
|
entityHwTxFail(804), -- HW or Tx failure
|
|
entitySwMismatch(806), -- SW version mismatch detected
|
|
entitySwUpgrade(807), -- Software Upgrade in progress
|
|
entitySwInvalidBank(808), -- Software Bank is invalid
|
|
entityIpLanPending(820), -- new LAN IP address is pending
|
|
entityIpOscPending(821), -- new OSC IP address is pending
|
|
nePowerFault(902), -- Power supply unit has failed
|
|
neFanFault(903), -- Fan unit has failed
|
|
neLowVoltagePower(904), -- The voltage of the Power Supply is too low
|
|
entitySwUpgradeFail(905), -- SW Upgrade Failed
|
|
entityRadiusPrimFail(906), -- Radius Primary Server failed
|
|
entityRadiusSecFail(907), -- Radius Secondary Server failed
|
|
entityDbRestoreFail(908), -- Database Restore Failed
|
|
entityDbRestoreInProgress(909), -- Database Restore In Progress
|
|
entitySntpFail(910), -- SNTP server failure
|
|
|
|
-- Misc
|
|
dcActive(1001), -- An alarm on the input dry contact
|
|
lcpDown(1002), -- The LCP link is down
|
|
ncpDown(1003), -- The NCP link is down
|
|
rtcFailure(1004) -- RTC failure
|
|
}
|
|
|
|
|
|
slAlarmConfig OBJECT IDENTIFIER ::= { slAlarmMib 1 }
|
|
slAlarmTraps OBJECT IDENTIFIER ::= { slAlarmMib 2 }
|
|
slAlarmTraps0 OBJECT IDENTIFIER ::= { slAlarmTraps 0 }
|
|
|
|
--
|
|
-- SL Alarms config Table
|
|
--
|
|
|
|
slAlarmConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SlAlarmConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains objects to configure the SL Alarms."
|
|
::= { slAlarmConfig 1 }
|
|
|
|
slAlarmConfigEntry OBJECT-TYPE
|
|
SYNTAX SlAlarmConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry exist for each type of alarm.
|
|
The entry describes the alarm properties."
|
|
INDEX { slAlarmIfIndex, slAlarmType }
|
|
::= { slAlarmConfigTable 1 }
|
|
|
|
SlAlarmConfigEntry ::=
|
|
SEQUENCE {
|
|
slAlarmIfIndex InterfaceIndex,
|
|
slAlarmType SlAlarmType,
|
|
slAlarmSeverity INTEGER,
|
|
slAlarmServiceAffect TruthValue,
|
|
slAlarmTimeStamp TimeStamp,
|
|
slAlarmAcknowledged TruthValue,
|
|
slAlarmAckUser DisplayString,
|
|
slAlarmText DisplayString
|
|
}
|
|
|
|
slAlarmIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The corresponding interface index.
|
|
The interface type may be one of:
|
|
- Sonet Line,
|
|
- Sonet Path,
|
|
- CLU
|
|
- NE."
|
|
::= { slAlarmConfigEntry 1 }
|
|
|
|
slAlarmType OBJECT-TYPE
|
|
SYNTAX SlAlarmType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The alarm type."
|
|
::= { slAlarmConfigEntry 2 }
|
|
|
|
slAlarmSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAlarm(0),
|
|
critical(1),
|
|
major(2),
|
|
minor(3),
|
|
cleared(4),
|
|
notification(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The alarm severity."
|
|
::= { slAlarmConfigEntry 3 }
|
|
|
|
slAlarmServiceAffect OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The alarm service affecting Yes/No."
|
|
::= { slAlarmConfigEntry 4 }
|
|
|
|
slAlarmTimeStamp OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The calendar time of the alarm."
|
|
::= { slAlarmConfigEntry 5 }
|
|
|
|
slAlarmAcknowledged OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Allow the NMS to acknowledge an active alarm."
|
|
::= { slAlarmConfigEntry 6 }
|
|
|
|
slAlarmAckUser OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the user that performed the Ack."
|
|
::= { slAlarmConfigEntry 7 }
|
|
|
|
slAlarmText OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The alarm text."
|
|
::= { slAlarmConfigEntry 8 }
|
|
|
|
|
|
--
|
|
-- SL ALARM TRAPS
|
|
--
|
|
|
|
slAlarmActive OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The alarm is active Yes/No."
|
|
::= { slAlarmTraps 1 }
|
|
|
|
slAlarmTrap NOTIFICATION-TYPE
|
|
OBJECTS {slAlarmIfIndex,
|
|
slAlarmType,
|
|
slAlarmSeverity,
|
|
slAlarmServiceAffect,
|
|
slAlarmActive,
|
|
slAlarmText
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An slAlarmTrap notification is sent when an alarm occures."
|
|
::= { slAlarmTraps 2 }
|
|
|
|
|
|
slAlarmTrap0 NOTIFICATION-TYPE
|
|
OBJECTS {slAlarmIfIndex,
|
|
slAlarmType,
|
|
slAlarmSeverity,
|
|
slAlarmServiceAffect,
|
|
slAlarmActive,
|
|
slAlarmText
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An slAlarmTrap0 notification is sent when an alarm occures.
|
|
It is defined to support browsers that don't recognize RFC 2576."
|
|
::= { slAlarmTraps0 2 }
|
|
|
|
|
|
END
|
|
|
|
|
|
|