-- Alarm MIB
-- *****************************************************************
SL-ALARM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
NOTIFICATION-TYPE FROM SNMPv2-SMI
TEXTUAL-CONVENTION, DisplayString,
TruthValue, TimeStamp FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP,
NOTIFICATION-GROUP FROM SNMPv2-CONF
InterfaceIndex FROM IF-MIB
PerfCurrentCount, PerfIntervalCount,
PerfTotalCount FROM PerfHist-TC-MIB
slMain FROM SL-MAIN-MIB;
slAlarmMib MODULE-IDENTITY
LAST-UPDATED "0008280000Z"
ORGANIZATION "PacketLight Networks Ltd."
CONTACT-INFO
"Omri_Viner@PacketLight.com"
DESCRIPTION
"This MIB module describes the ALARMS."
::= { slMain 20 }
SlAlarmType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The Alarms Types."
SYNTAX INTEGER {
-- SONET/SDH alarms
losSonetAlarm(1), -- Loss Of Signal (S)
lofSonetAlarm(2), -- Loss Of Frame (S)
lopSonetAlarm(3), -- Loss Of Pointer (P)
aisLineSonetAlarm(4), -- Alarm Indication Signal (L)
rfiLineSonetAlarm(5), -- Remote Failure Indication (L)
uneqSonetAlarm(6), -- Unequipped (P)
timLine(7), -- Trace Indication Mismatch (S)
slm(8), -- Signal Label Mismatch (P) - Defect
sd(9), -- Signal Degrade (SDH only)
sf(10), -- Signal Fail (SDH only)
hwfail(11), -- HW Fail
aisPathSonetAlarm(12), -- Alarm Indication Signal (P)
rfiPathSonetAlarm(13), -- Remote Failure Indication (P)
timPath(14), -- Trace Indication Mismatch (P)
uplinkTransmitMismatch(15), -- Transceiver mismatch or removed (deprecated)
uplinkClockSourceLol(16), -- Clock Source Loss of lock
aisVtSonetAlarm(21), -- Alarm Indication Signal (V)
lopVtSonetAlarm(22), -- Loss Of Pointer (V)
rfiVtSonetAlarm(23), -- Remote Failure Indication (V)
timVt(24), -- Trace Indication Mismatch (V)
slmVt(25), -- Signal Label Mismatch (V)
uneqVtSonetAlarm(26), -- Unequipped (V)
lomVt(27), -- Loss of Multiframe (V)
-- GFP/VCG alarms
vcgFarLossClientSignal(101),-- Far-end Loss of Client Signal
vcgFarLossClientSync(102), -- Far-end Loss of Client Sync
vcgLossAlignment(103), -- VCG Loss of Alignment
vcgLossMultiframe(104), -- VCG Loss of Multiframe
vcgLossSequence(105), -- VCG Loss of Sequence
vcgGfpLossSync(106), -- GFP framer Loss of Sync
vcgFarGfpLossSync(107), -- Far-end GFP Loss of Sync
vcgBadGidMember(108), -- Bad GID of a VCAT member
-- Provisioning alarms
provUnequipped(151), -- Unprovisioned service
provMismatch(152), -- Mismatch provisioning
-- Ethernet alarms
ethConfigTransmitFault(201),-- Optical GbE transceiver transmit fault (deprecated)
ethConfigLossOfSignal(202), -- Optical GbE transceiver signal detect failed
ethConfigLinkFail(203), -- Mac Layer Link failed
ethConfigPcsLossSync(204), -- PCS coding loss of sync
-- FC alarms
fcBxPortTransmitFault(301), -- Transceiver transmit fault (deprecated)
fcBxPortLossOfSignal(302), -- Transceiver signal detect failed
fcBxPortNoLink(303), -- No link established yet.
fcBxPortLossOfSync(304), -- Loss of sync
fcBxPortTransmitMismatch(306), -- Transceiver mismatch or removed (deprecated)
fcBxPortPcsLossSync(307), -- PCS coding loss of sync
fcipLinkNoLink(311), -- No link established yet.
fcipLinkLossOfSync(312), -- Loss of sync
fcipSntpFailure(313), -- SNTP failure
fcipIpsecFailure(314), -- IPSec failure
fcipFarLossOfClient(315), -- The Far-End lost the FC link
-- Escon alarms
esconPortTransmitFault(351), -- Transceiver transmit fault (deprecated)
esconPortLossOfSignal(352), -- Transceiver signal detect failed
esconPortNoLink(353), -- No link established yet.
esconPortLossOfSync(354), -- Loss of sync
-- EDFA alarms
edfaPumpTemperuture(401), -- Pump temperatur is out-of-bound
edfaHwFail(403), -- Pump HW failure
edfaRvcSignalDetect(404), -- Loss of input signal
edfaRcvPower(406), -- Rx Power is out-of-bound
edfaTemprature(407), -- Edfa temperature is out-of-bound
edfaEyeSafty(408), -- Eye safety alarm (available only in eye-safety mode)
edafGainFlatness(409), -- Gain flatness alarm
edfaXmtPower(410), -- Tx Power is out-of-bound
edfaGain(411), -- Edfa Gain is out-of-bound
edfaEol(412), -- Pump End Of Life
-- Muxponder alarms
muxAisPath(451) , -- Muxponder AIS
muxLof(452), -- Muxponder LOF
muxRdi(453), -- Muxponder RDI
muxInbandFail(454), -- Muxponder Inband Fail
muxTempLicense(455), -- Muxponder Temporary Licensed
muxNoLicense(456), -- Muxponder Not Licensed
-- Optical Switch alarms
oswHwFail(470), -- The optical switch is defined in seep but not exist
oswLossOfSignal(471), -- LOS is detected on the port of the optical switch
oswEdfaLossProp(472),
-- Port alarms
loopback(501), -- The port is in loopback
apsForceActive(502), -- Force Switch is active on this port
apsManualActive(503), -- Manual Switch is active on this port
-- CLU alarms
cluHoldoverState(602), -- Clu is switched to holdover
cluFreerunState(603), -- Clu is in free run state
cluBelowLevel(604), -- Clock is below internal level
cluFail(606), -- Clock fail
cluJittered(608), -- Clock jittered
-- WSS alarms
channelLowDegrade(621), -- OCM Power Level Parameter 2
channelHighDegrade(622), -- OCM Power Level Parameter 3
channelLowFail(623), -- OCM Power Level Parameter 4
channelHighFail(624), -- OCM Power Level Parameter 5
unequalizedOuputPower(625), -- Failed to equalize channels output power
-- SFP Alarms
sfpTransmitFault(701), -- sfp hardware problem
sfpRemoved(702), -- spf is either removed or failed
sfpMuxWlMismatch(703), -- wl of the sfp does not match the wls of the mux
sfpBitRateMismatch(704), -- the sfp bit rate does not match the implied port rate
sfpLossOfLock(705), -- retimer problem
sfpSfpWlMismatch(706), -- two sfps with the same wave length in
sfpLossOfLight(707), -- no signnal detection
sfpLaserEndOfLife(708), -- laser end of life indication
sfpMuxSpacingMismatch(709), -- spacing of the sfp does not match the spacing of the mux
sfpHardwareFault(710), -- wrong sfp crc
sfpBlocked(711), -- the sfp is blocked
sfpLossPropagation(712), -- shut laser due to a problem with the mate sfp
sfpUnknownType(713), -- unknown sfp type warning - doesn't shut the laser
sfpHighTemp(720), -- internal temperature exceeds high alarm level.
sfpLowTemp(721), -- internal temperature is below low alarm level.
sfpHighTxPower(726), -- TX output power exceeds high alarm level.
sfpLowTxPower(727), -- TX output power is below low alarm level.
sfpHighRxPower(728), -- Received Power exceeds high alarm level.
sfpLowRxPower(729), -- Received Power is below low alarm level.
sfpHighLaserTemp(730), -- (15xy) laser TEC current exceeds high alarm level.
sfpLowLaserTemp(731), -- (15xy) laser TEC current exceeds low alarm level.
sfpHighLaserWl(732), -- (15xy) laser wavelength exceeds high alarm level.
sfpLowLaserWl(733), -- (15xy) laser wavelength is below low alarm level.
-- XFP Alarms
xfpTxNR(734),
xfpTxCdrNotLocked(735),
xfpRxNR(736),
xfpRxCdrNotLocked(737),
-- OTN Alarms
otnFecExc(750), -- FEC-EXC Trail Excessive Errors (Early FEC) > 10-4
otnFecDeg(751), -- FEC-DEG Trail Degraded Errors (Early FEC) > 10-8
otnOtuDeg(752), -- S-DEG Section- Degraded Performance. Based on SM BIP
otnOduDeg(753), -- P-DEG Path- Degraded Performance. Based on PM BIP
otnLos(754), -- LOS Loss of Signal
otnLof(755), -- LOF Loss of Frame. OOF present for at least 3ms
otnLom(756), -- LOM Loss of Multiframe; OOM present for at least 3ms
otuAis(757), -- S-AIS Section-Alarm Indication Signal
otuBdi(758), -- S-BDI Section-Backward Defect Indicator
otuTtim(759), -- S-TTIM Section-Trail Trace Identifier Mismatch (SAPI/DAPI)
oduAis(780), -- P-AIS Path-Alarm Indication Signal
oduOci(781), -- P-OCI Path-Open Connection indicator
oduLck(782), -- P-LCK Path-Locked. Path Locked active
oduBdi(783), -- P-BDI Path-Backward Error indicator.
oduTtim(784), -- P-TTIM Path-Trail Trace Identifier Mismatch (SAPI/DAPI)
oduPtm(785), -- P-PTM Path Payload Type Mismatch
-- NE alarms
entityRemoved(801), -- Card is removed from the slot
entityClockFail(803), -- Clock Failure
entityHwTxFail(804), -- HW or Tx failure
entitySwMismatch(806), -- SW version mismatch detected
entitySwUpgrade(807), -- Software Upgrade in progress
entitySwInvalidBank(808), -- Software Bank is invalid
entityIpLanPending(820), -- new LAN IP address is pending
entityIpOscPending(821), -- new OSC IP address is pending
nePowerFault(902), -- Power supply unit has failed
neFanFault(903), -- Fan unit has failed
neLowVoltagePower(904), -- The voltage of the Power Supply is too low
entitySwUpgradeFail(905), -- SW Upgrade Failed
entityRadiusPrimFail(906), -- Radius Primary Server failed
entityRadiusSecFail(907), -- Radius Secondary Server failed
entityDbRestoreFail(908), -- Database Restore Failed
entityDbRestoreInProgress(909), -- Database Restore In Progress
entitySntpFail(910), -- SNTP server failure
-- Misc
dcActive(1001), -- An alarm on the input dry contact
lcpDown(1002), -- The LCP link is down
ncpDown(1003), -- The NCP link is down
rtcFailure(1004) -- RTC failure
}
slAlarmConfig OBJECT IDENTIFIER ::= { slAlarmMib 1 }
slAlarmTraps OBJECT IDENTIFIER ::= { slAlarmMib 2 }
slAlarmTraps0 OBJECT IDENTIFIER ::= { slAlarmTraps 0 }
--
-- SL Alarms config Table
--
slAlarmConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlAlarmConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects to configure the SL Alarms."
::= { slAlarmConfig 1 }
slAlarmConfigEntry OBJECT-TYPE
SYNTAX SlAlarmConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry exist for each type of alarm.
The entry describes the alarm properties."
INDEX { slAlarmIfIndex, slAlarmType }
::= { slAlarmConfigTable 1 }
SlAlarmConfigEntry ::=
SEQUENCE {
slAlarmIfIndex InterfaceIndex,
slAlarmType SlAlarmType,
slAlarmSeverity INTEGER,
slAlarmServiceAffect TruthValue,
slAlarmTimeStamp TimeStamp,
slAlarmAcknowledged TruthValue,
slAlarmAckUser DisplayString,
slAlarmText DisplayString
}
slAlarmIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The corresponding interface index.
The interface type may be one of:
- Sonet Line,
- Sonet Path,
- CLU
- NE."
::= { slAlarmConfigEntry 1 }
slAlarmType OBJECT-TYPE
SYNTAX SlAlarmType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm type."
::= { slAlarmConfigEntry 2 }
slAlarmSeverity OBJECT-TYPE
SYNTAX INTEGER {
noAlarm(0),
critical(1),
major(2),
minor(3),
cleared(4),
notification(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm severity."
::= { slAlarmConfigEntry 3 }
slAlarmServiceAffect OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm service affecting Yes/No."
::= { slAlarmConfigEntry 4 }
slAlarmTimeStamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The calendar time of the alarm."
::= { slAlarmConfigEntry 5 }
slAlarmAcknowledged OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allow the NMS to acknowledge an active alarm."
::= { slAlarmConfigEntry 6 }
slAlarmAckUser OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the user that performed the Ack."
::= { slAlarmConfigEntry 7 }
slAlarmText OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm text."
::= { slAlarmConfigEntry 8 }
--
-- SL ALARM TRAPS
--
slAlarmActive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm is active Yes/No."
::= { slAlarmTraps 1 }
slAlarmTrap NOTIFICATION-TYPE
OBJECTS {slAlarmIfIndex,
slAlarmType,
slAlarmSeverity,
slAlarmServiceAffect,
slAlarmActive,
slAlarmText
}
STATUS current
DESCRIPTION
"An slAlarmTrap notification is sent when an alarm occures."
::= { slAlarmTraps 2 }
slAlarmTrap0 NOTIFICATION-TYPE
OBJECTS {slAlarmIfIndex,
slAlarmType,
slAlarmSeverity,
slAlarmServiceAffect,
slAlarmActive,
slAlarmText
}
STATUS current
DESCRIPTION
"An slAlarmTrap0 notification is sent when an alarm occures.
It is defined to support browsers that don't recognize RFC 2576."
::= { slAlarmTraps0 2 }
END