-- SONET MIB
-- *****************************************************************
SL-SONET-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
NOTIFICATION-TYPE, Counter64,
Gauge32 FROM SNMPv2-SMI
DisplayString, TruthValue, RowStatus
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP,
NOTIFICATION-GROUP FROM SNMPv2-CONF
InterfaceIndex, ifIndex FROM IF-MIB
PerfCurrentCount, PerfIntervalCount,
PerfTotalCount FROM PerfHist-TC-MIB
sitelight FROM SL-NE-MIB;
slSonetMib MODULE-IDENTITY
LAST-UPDATED "200008280000Z"
ORGANIZATION "PacketLight Networks Ltd."
CONTACT-INFO
"Omri_Viner@PacketLight.com"
DESCRIPTION
"This MIB module describes the SiteLight SONET Service.
The mib contains the extensions required for the rfc2558."
::= { sitelight 6 }
SignalLabel ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"STS path signal label -- one byte, C2, class A, is allocated to
indicate the construction of the STS SPE.
The following hex values of the C2 byte has been defined."
SYNTAX INTEGER {
sigUnequipped(0), -- Unequipped signal (no path originate equipment)
sigEquipped(1), -- Equipped signal (standard payload)
sigPathFloatVt(2), -- Floating VT mode
sigPathLoackedVt(3), -- Locked VT mode
sigPathAsynchDs3(4), -- Asynchronous mapping for DS3
sigPathSyntran(5), -- Mapping byte observable SYNTRAN
sigPathAsyncDs4na(18), -- Asynchronous mapping for 139.264 Mbps
sigPathAtm(19), -- Mapping for ATM
sigPathDqdb(20), -- Mapping for DQDB
sigPathFddi(21), -- Asynchronous mapping for FDDI
sigPathHdlc(22), -- HDLC-Over-SONET Mapping
sigPathGfp(27) -- GFP Mapping
}
slSonetConfig OBJECT IDENTIFIER ::= { slSonetMib 1}
slSonetOh OBJECT IDENTIFIER ::= { slSonetMib 2 }
-- slSonetPmMib OBJECT IDENTIFIER ::= {slSonetMib 3}
-- slSonetAlarmsMib OBJECT IDENTIFIER ::= {slSonetMib 4}
-- slSonetApsMib OBJECT IDENTIFIER ::= {slSonetMib 5}
slSonetPos OBJECT IDENTIFIER ::= { slSonetMib 6 }
slSonetAls OBJECT IDENTIFIER ::= { slSonetMib 7 }
slSonetFs OBJECT IDENTIFIER ::= { slSonetMib 8 }
slSonetTraps OBJECT IDENTIFIER ::= { slSonetMib 11 }
slSonetOhTrace OBJECT IDENTIFIER ::= {slSonetOh 1} -- Trace Message
slSonetOhSl OBJECT IDENTIFIER ::= {slSonetOh 2} -- Signal Label
slSonetOhTraps OBJECT IDENTIFIER ::= {slSonetOh 3} -- Mismatch Traps
------------------------------
--
-- Sonet Config table
--
------------------------------
slSonetConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlSonetConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET/SDH configuration table. This table has objects
for configuring sonet lines."
::= { slSonetConfig 1 }
slSonetConfigEntry OBJECT-TYPE
SYNTAX SlSonetConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table. There is an entry for each SONET line
in the table. Entries are automatically created for an
ifType value of sonet(39). 'ifAdminStatus' from the ifTable
must be used to enable or disable a line. By default, the
line state is down."
INDEX { ifIndex }
::= { slSonetConfigTable 1 }
SlSonetConfigEntry ::=
SEQUENCE {
slSonetConfigFrameScramble INTEGER,
slSonetConfigType INTEGER, -- deprecated
slSonetConfigDccSelection INTEGER,
slSonetResetAllCounters INTEGER,
slSonetPortThresholdTrapEnable INTEGER,
slSonetConfigSdThreshold INTEGER,
slSonetConfigSfThreshold INTEGER,
slSonetCompression INTEGER,
slSonetOverheadTunneling INTEGER,
slSonetLopBitmask Counter64, -- deprecated
slSonetTdmTrunk TruthValue,
slSonetFsApply INTEGER, -- deprecated
slSonetTxLte INTEGER,
slSonetReceivedLte INTEGER,
slSonetResetPmThreshold INTEGER,
slSonetResetAlsParams INTEGER,
slSonetTransceiverType INTEGER,
slSonetTransceiverMedia INTEGER
}
slSonetConfigFrameScramble OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to disable or enable the Scrambling
option in SONET line. Please refer to GR-253-CORE for
frame scrambling."
REFERENCE
"GR-253-CORE"
DEFVAL { enabled }
::= {slSonetConfigEntry 1}
slSonetConfigType OBJECT-TYPE
SYNTAX INTEGER {
sonetSts3(1), -- deprecated
sonetSts3c(2), -- deprecated
sonetSts12(3), -- deprecated
sonetSts12c(4), -- deprecated
sonetSts48c(5),
sonetSts3cx4(6), -- deprecated
sonetSts48(7), -- deprecated
sonetSts3cx16(8), -- deprecated
sonetSts3x16(9), -- deprecated
sonetSts12cx4(10), -- deprecated
sonetSts12x4(11), -- deprecated
sonetSts192c(12),
sonetStsOther(13)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object represents the configured line type for Trunks:
sonetSts48c(5) - 1 x Sts48 (2.5GbTrunk)
sonetSts192c(12) - 1 x Sts192 (10Gb Trunk)
sonetStsOther(13) - for OC-n interfaces see slSonetFsTable."
::= {slSonetConfigEntry 2}
slSonetConfigDccSelection OBJECT-TYPE
SYNTAX INTEGER {
sonetLineDcc(1),
sonetSectionDcc(2),
sonetInband(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object selects the DCC type."
::= {slSonetConfigEntry 3 }
slSonetResetAllCounters OBJECT-TYPE
SYNTAX INTEGER {
resetCounters(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this variable to 1 will cause all of the counters
(performance regsters) on this SONET interface to be initialized
to zero (0)."
REFERENCE "ANSI T1.231-1997 clause 9.1.5.1."
::= { slSonetConfigEntry 4 }
slSonetPortThresholdTrapEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates whether threshold traps
should be generated for this SONET interface."
REFERENCE "ANSI T1.231-1997 clause 9.1.5.2."
DEFVAL { disabled }
::= { slSonetConfigEntry 5 }
slSonetConfigSdThreshold OBJECT-TYPE
SYNTAX INTEGER (5..9)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object contains the Bit Error Rate threshold for
Signal Degrade detection on the working line. Once this
threshold is exceeded, an APS switch will occur.
This value is 10 to -n where n is between 5 and 9
(read-write)."
DEFVAL {5}
::= { slSonetConfigEntry 6 }
slSonetConfigSfThreshold OBJECT-TYPE
SYNTAX INTEGER (3..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object contains the Bit Error Rate threshold for
Signal Fault detection on the working line. Once this
threshold is exceeded, an APS switch will occur.
This value is 10 to the -n, where n is between 3 and 5.
(read-write)"
DEFVAL {3}
::= { slSonetConfigEntry 7 }
slSonetCompression OBJECT-TYPE
SYNTAX INTEGER {
uncompress(0),
posCompress32(1),
posCompress16(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object applies only for trunk ports.
It specifies if the packets should be compressed.
0 - Means no POS compression,
1 - Means POS compression with CRC-32.
2 - Means POS compression with CRC-16.
Note that the two connected trunks should be configured
to the same value.
Note also that the BW calculation of the OC-n should
be changed according to this value."
::= { slSonetConfigEntry 9 }
slSonetOverheadTunneling OBJECT-TYPE
SYNTAX INTEGER {
none(0),
lineDcc(1),
k1k2(2),
full(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The section and line overhead tunneling configuration:
none(0) - no tunneling support
lineDcc(1) - line DCC tunneling
k1k2(2) - line DCC + protection k byte
full(3) - all transport overhead bytes are tunneled"
::= { slSonetConfigEntry 10 }
slSonetLopBitmask OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current -- deprecated
DESCRIPTION
"The LOP status. Each bit of the bits represent the status
of the LOP alarm in corresponding STS.
For a path with more than a single STS, only the value of the
first STS in the path is relevant.
This object is relevant only for the OC-N cards and not
for the Trunk.
In the next future this object will be replaced with
an object of a new table that shall describe the OC-N
frame structure."
::= { slSonetConfigEntry 11 }
slSonetTdmTrunk OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only to the OC-n ports.
TRUE - means that the OC-n port is used as a TDM Trunk.
FLASE - means normal OC-n port."
::= { slSonetConfigEntry 12 }
slSonetFsApply OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write -- deprecated
STATUS current
DESCRIPTION
"Writing to this object activate the slSonetFsTable setting.
This allow the NMS to do many changes to the slSonetFsTable
and then APPLY them at once. This prevent from going through
unconsistent steps.
This object always returns the value 0."
::= { slSonetConfigEntry 13 }
slSonetTxLte OBJECT-TYPE
SYNTAX INTEGER {
ssb00(1), -- SONET
ssb10(2), -- SDH
auto(5) -- Tx what is detected
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SS bits to transmit (bits 5,6 in H1,H1*)."
::= { slSonetConfigEntry 14 }
slSonetReceivedLte OBJECT-TYPE
SYNTAX INTEGER {
ssb00(1), -- SONET
ssb10(2), -- SDH
ssb01(3), -- other
ssb11(4), -- other
ssbinv(5) -- invalid
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The detected LTE type, according to the received SS bits
(bits 5,6 in H1,H1*)."
::= { slSonetConfigEntry 15 }
slSonetResetPmThreshold OBJECT-TYPE
SYNTAX INTEGER {
resetCounters(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this variable to 1 will reset the PM threshold
parameters to the factory defaults."
REFERENCE "ANSI T1.231-1997 clause 9.1.5.1."
::= { slSonetConfigEntry 16 }
slSonetResetAlsParams OBJECT-TYPE
SYNTAX INTEGER {
resetCounters(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this variable to 1 will reset the ALS
parameters to the factory defaults."
REFERENCE "ANSI T1.231-1997 clause 9.1.5.1."
::= { slSonetConfigEntry 17 }
slSonetTransceiverType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
shortWave(2), -- 850nm
longWave(3) -- 1310nm
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The tranceiver type."
::= { slSonetConfigEntry 18 }
slSonetTransceiverMedia OBJECT-TYPE
SYNTAX INTEGER {
none(1), --
sm(2), -- Single Mode
mm(3) -- Multi Mode
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The tranceiver media."
::= { slSonetConfigEntry 19 }
-- ----------------------------------------------------------------
--
-- Sonet Trace Table
--
-- ----------------------------------------------------------------
slSonetTraceTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlSonetTraceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET/SDH Trace table. This table contains
objects for tracing the sonet section and path."
::= { slSonetOhTrace 1 }
slSonetTraceEntry OBJECT-TYPE
SYNTAX SlSonetTraceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the trace table. Entries exist for active sonet
interfaces. The objects in this table are used to verify
continued connection between the two ends of the line."
INDEX { ifIndex }
::= { slSonetTraceTable 1 }
SlSonetTraceEntry ::=
SEQUENCE {
slSonetTraceMode INTEGER,
slSonetTraceToTransmit DisplayString,
slSonetTraceToExpect DisplayString,
slSonetTraceFailure TruthValue,
slSonetTraceReceived DisplayString
}
slSonetTraceMode OBJECT-TYPE
SYNTAX INTEGER {
enable(1), -- notification and rdi
disable(2), -- no notification and no rdi
monitoring(3) -- only notification and no rdi
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determine the Trace Message Mode."
REFERENCE
"GR-253-CORE"
::= { slSonetTraceEntry 1 }
slSonetTraceToTransmit OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..62))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sonet Trace To Transmit. This is string that
is transmitted to perform Sonet trace
diagnostics. The trace string is repetitively
transmited so that a trace receiving terminal can
verify its continued connection to the intended
transmitter. The default value is a zero-length string.
Unless this object is set to a non-zero length string,
tracing will not be performed.
The Agent is responsible to pad the end of the string with <CR><LF>."
REFERENCE
"GR-253-CORE"
::= { slSonetTraceEntry 2 }
slSonetTraceToExpect OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..62))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sonet Trace Massage To Expect. The receiving terminal
verifies if the incoming string matches this string.
The value of 'slSonetTraceFailure' indicates whether a
trace mismatch occurred. The default value is a
zero-length string.
The Agent is responsible to pad the end of the string with <CR><LF>."
REFERENCE
"GR-253-CORE"
::= { slSonetTraceEntry 3 }
slSonetTraceFailure OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is set to 'true' when Sonet
Section received trace does not match the
'slSonetTraceToExpect'."
REFERENCE
"GR-253-CORE"
::= { slSonetTraceEntry 4 }
slSonetTraceReceived OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..62))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to view the Sonet Trace Message that
is received by the receiving terminal.
The Agent is responsible to pad the end of the string with <CR><LF>."
REFERENCE
"GR-253-CORE"
::= { slSonetTraceEntry 5 }
-- ----------------------------------------------------------------
--
-- Signal Label Table
--
-- ----------------------------------------------------------------
slSonetSlTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlSonetSlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET/SDH Signal Label table. This table contains
signal label for the sonet path."
::= { slSonetOhSl 1 }
slSonetSlEntry OBJECT-TYPE
SYNTAX SlSonetSlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET/SDH Signal Label table. The entries
exist for active sonet lines. The objects in this table are
used to verify continued connection between the two ends of
the line."
INDEX { ifIndex }
::= { slSonetSlTable 1 }
SlSonetSlEntry ::=
SEQUENCE {
slSonetSlToTransmit SignalLabel,
slSonetSlToExpect SignalLabel,
slSonetSlFailure TruthValue,
slSonetSlReceived INTEGER
}
slSonetSlToTransmit OBJECT-TYPE
SYNTAX SignalLabel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sonet Signal Label To Transmit."
REFERENCE
"GR-253-CORE"
::= { slSonetSlEntry 2 }
slSonetSlToExpect OBJECT-TYPE
SYNTAX SignalLabel
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sonet Signal Label To Expect."
REFERENCE
"GR-253-CORE"
::= { slSonetSlEntry 3 }
slSonetSlFailure OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is set to 'true' when Sonet
received signal label does not match the 'slSonetSlToExpect'."
REFERENCE
"GR-253-CORE"
::= { slSonetSlEntry 4 }
slSonetSlReceived OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to view the Sonet Signal Label that is
received by the receiving terminal."
REFERENCE
"GR-253-CORE"
::= { slSonetSlEntry 5 }
-- ----------------------------------------------------------------
--
-- Packets Over Sonet/Sdh (POS) Performance Monitoring (PM) Table
--
-- ----------------------------------------------------------------
slSonetPosTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlSonetPosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The POS PM Table."
::= { slSonetPos 1 }
slSonetPosEntry OBJECT-TYPE
SYNTAX SlSonetPosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entries exist for active Trunk sonet lines
ifType = pos(171). The objects in this table are
used to moitor the POS layer."
INDEX { ifIndex }
::= { slSonetPosTable 1 }
SlSonetPosEntry ::=
SEQUENCE {
slSonetPosFcs Gauge32,
slSonetPosAbort Gauge32,
slSonetPosMinViolation Gauge32,
slSonetPosMaxViolation Gauge32,
slSonetPosRxfifoDiscard Gauge32,
slSonetPosPacketReceived Counter64,
slSonetPosPacketReceivedOk Counter64
}
slSonetPosFcs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Number of FCS Errors."
::= { slSonetPosEntry 1 }
slSonetPosAbort OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Number of Aborted packets."
::= { slSonetPosEntry 2 }
slSonetPosMinViolation OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Number of Minimum length violation packets."
::= { slSonetPosEntry 3 }
slSonetPosMaxViolation OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Number of Maximum length violation packets."
::= { slSonetPosEntry 4 }
slSonetPosRxfifoDiscard OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Number of packets discarded due to RXFIFO error."
::= { slSonetPosEntry 5 }
slSonetPosPacketReceived OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Number of packets received."
::= { slSonetPosEntry 6 }
slSonetPosPacketReceivedOk OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Number of error free packets."
::= { slSonetPosEntry 7 }
-- ----------------------------------------------------------------
--
-- Automatic Laser Shutdown (ALS) Configuration Table
--
-- ----------------------------------------------------------------
slSonetAlsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlSonetAlsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ALS configuration Table."
::= { slSonetAls 1 }
slSonetAlsEntry OBJECT-TYPE
SYNTAX SlSonetAlsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entries exist for active sonet lines
ifType = sonet(39). The objects in this table are
used to configure the ALS algorithm."
INDEX { ifIndex }
::= { slSonetAlsTable 1 }
SlSonetAlsEntry ::=
SEQUENCE {
slSonetAlsMode INTEGER,
slSonetLosDeclareTime INTEGER,
slSonetTestPulseTime INTEGER,
slSonetManualPulseTime INTEGER,
slSonetAutomaticPulseTime INTEGER,
slSonetAutomaticDelayTime INTEGER,
slSonetLaserTestActivate INTEGER,
slSonetLaserManualActivate INTEGER
}
slSonetAlsMode OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable the ALS algorithm.
Note that the if the Laser Admin Status is 'down' the
ALS mechanism is not operational."
::= { slSonetAlsEntry 1 }
slSonetLosDeclareTime OBJECT-TYPE
SYNTAX INTEGER {
ms500(1), -- 500 ms
ms550(2), -- 550 ms
ms600(3) -- 600 ms
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time to declare optical LOS present or clear: 550 +- 50 msec."
::= { slSonetAlsEntry 2 }
slSonetTestPulseTime OBJECT-TYPE
SYNTAX INTEGER {
s80(1), -- 80 sec
s90(2), -- 90 sec
s100(3) -- 100 sec
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Manual restart for test Pulse time (in manual restart) - 90+-10 sec."
::= { slSonetAlsEntry 3 }
slSonetManualPulseTime OBJECT-TYPE
SYNTAX INTEGER {
ms1750(1), -- 1.75 Sec
ms2000(2), -- 2.0 sec
ms2250(3) -- 2.25 sec
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Manual restart Pulse time (in manual mode) - 2+-0.25 sec."
::= { slSonetAlsEntry 4 }
slSonetAutomaticPulseTime OBJECT-TYPE
SYNTAX INTEGER {
ms1750(1), -- 1.75 Sec
ms2000(2), -- 2.0 sec
ms2250(3) -- 2.25 sec
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Automatic restart Pulse time (in automatic mode) - 2+-0.25 sec."
::= { slSonetAlsEntry 5 }
slSonetAutomaticDelayTime OBJECT-TYPE
SYNTAX INTEGER (60..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In Automatic mode. The delay between two laser re-activations."
::= { slSonetAlsEntry 6 }
slSonetLaserTestActivate OBJECT-TYPE
SYNTAX INTEGER { activate(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Activate the laser for test operation."
::= { slSonetAlsEntry 7 }
slSonetLaserManualActivate OBJECT-TYPE
SYNTAX INTEGER { activate(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Activate the laser manual operation."
::= { slSonetAlsEntry 8 }
-- ----------------------------------------------------------------
--
-- Frame Structure Configuration Table
--
-- ----------------------------------------------------------------
slSonetFsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlSonetFsEntry
MAX-ACCESS not-accessible -- deprecated
STATUS current
DESCRIPTION
"The frame structure configuration Table.
In order to define a new path the NMS should create and configure
an entry in this table.
The table is also used to monitor the status of the LOP
alarm per path."
::= { slSonetFs 1 }
slSonetFsEntry OBJECT-TYPE
SYNTAX SlSonetFsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entries exist for sonet paths
ifType = sonet(39). The objects in this table are
used to configure the frame structure.
Each OC-N line interface shall maintain a static
table with number of lines equal to the N.
Initially the table will be initialized to STS-Nc."
INDEX { slSonetFsIfIndex,
slSonetFsSts }
::= { slSonetFsTable 1 }
SlSonetFsEntry ::=
SEQUENCE {
slSonetFsIfIndex InterfaceIndex,
slSonetFsSts INTEGER,
slSonetFsWidth INTEGER,
slSonetFsFullPathTermination TruthValue,
slSonetFsGranularity INTEGER
}
slSonetFsIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface index."
::= { slSonetFsEntry 1 }
slSonetFsSts OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the first STS in the path.
Note that no all values are legal because there is no
support for combus with mixed structure"
::= { slSonetFsEntry 2 }
slSonetFsWidth OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number STS's in the path.
The width is only valid for the first STS in the path.
The other STSs of the path will have width=0."
::= { slSonetFsEntry 3 }
slSonetFsFullPathTermination OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"FALSE - means partial path termination (only LOP alarm).
TRUE - include full support for path Alarms and PM counters."
::= { slSonetFsEntry 4 }
slSonetFsGranularity OBJECT-TYPE
SYNTAX INTEGER {
vc4(1),
vc3(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value is set by the NMS according to the configured frame structure.
Each VC-3 that is mapped to AUG-1 via VC-4 should have the value vc4(1).
Otherwise the value should be vc3(2)."
::= { slSonetFsEntry 5 }
-- ----------------------------------------------------------------
--
-- Sonet Traps
--
-- ----------------------------------------------------------------
slSonetFsTableChange NOTIFICATION-TYPE
OBJECTS { slSonetFsIfIndex }
STATUS current
DESCRIPTION
"A slSonetFsTableChange trap is sent when the
content of the slSonetFsTable is changed.
This trap may be used by the NMS to identify
the removal of path interfaces, or addition of
new path interfaces"
::= { slSonetTraps 1 }