884 lines
27 KiB
Plaintext
884 lines
27 KiB
Plaintext
-- *****************************************************************
|
|
-- SONET MIB
|
|
-- *****************************************************************
|
|
|
|
SL-SONET-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
NOTIFICATION-TYPE, Counter64,
|
|
Gauge32 FROM SNMPv2-SMI
|
|
DisplayString, TruthValue, RowStatus
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP,
|
|
NOTIFICATION-GROUP FROM SNMPv2-CONF
|
|
InterfaceIndex, ifIndex FROM IF-MIB
|
|
PerfCurrentCount, PerfIntervalCount,
|
|
PerfTotalCount FROM PerfHist-TC-MIB
|
|
sitelight FROM SL-NE-MIB;
|
|
|
|
slSonetMib MODULE-IDENTITY
|
|
LAST-UPDATED "200008280000Z"
|
|
ORGANIZATION "PacketLight Networks Ltd."
|
|
CONTACT-INFO
|
|
"Omri_Viner@PacketLight.com"
|
|
DESCRIPTION
|
|
"This MIB module describes the SiteLight SONET Service.
|
|
The mib contains the extensions required for the rfc2558."
|
|
::= { sitelight 6 }
|
|
|
|
SignalLabel ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"STS path signal label -- one byte, C2, class A, is allocated to
|
|
indicate the construction of the STS SPE.
|
|
The following hex values of the C2 byte has been defined."
|
|
SYNTAX INTEGER {
|
|
sigUnequipped(0), -- Unequipped signal (no path originate equipment)
|
|
sigEquipped(1), -- Equipped signal (standard payload)
|
|
sigPathFloatVt(2), -- Floating VT mode
|
|
sigPathLoackedVt(3), -- Locked VT mode
|
|
sigPathAsynchDs3(4), -- Asynchronous mapping for DS3
|
|
sigPathSyntran(5), -- Mapping byte observable SYNTRAN
|
|
sigPathAsyncDs4na(18), -- Asynchronous mapping for 139.264 Mbps
|
|
sigPathAtm(19), -- Mapping for ATM
|
|
sigPathDqdb(20), -- Mapping for DQDB
|
|
sigPathFddi(21), -- Asynchronous mapping for FDDI
|
|
sigPathHdlc(22), -- HDLC-Over-SONET Mapping
|
|
sigPathGfp(27) -- GFP Mapping
|
|
}
|
|
|
|
slSonetConfig OBJECT IDENTIFIER ::= { slSonetMib 1}
|
|
slSonetOh OBJECT IDENTIFIER ::= { slSonetMib 2 }
|
|
-- slSonetPmMib OBJECT IDENTIFIER ::= {slSonetMib 3}
|
|
-- slSonetAlarmsMib OBJECT IDENTIFIER ::= {slSonetMib 4}
|
|
-- slSonetApsMib OBJECT IDENTIFIER ::= {slSonetMib 5}
|
|
slSonetPos OBJECT IDENTIFIER ::= { slSonetMib 6 }
|
|
slSonetAls OBJECT IDENTIFIER ::= { slSonetMib 7 }
|
|
slSonetFs OBJECT IDENTIFIER ::= { slSonetMib 8 }
|
|
slSonetTraps OBJECT IDENTIFIER ::= { slSonetMib 11 }
|
|
|
|
slSonetOhTrace OBJECT IDENTIFIER ::= {slSonetOh 1} -- Trace Message
|
|
slSonetOhSl OBJECT IDENTIFIER ::= {slSonetOh 2} -- Signal Label
|
|
slSonetOhTraps OBJECT IDENTIFIER ::= {slSonetOh 3} -- Mismatch Traps
|
|
|
|
------------------------------
|
|
--
|
|
-- Sonet Config table
|
|
--
|
|
------------------------------
|
|
|
|
slSonetConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SlSonetConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SONET/SDH configuration table. This table has objects
|
|
for configuring sonet lines."
|
|
::= { slSonetConfig 1 }
|
|
|
|
slSonetConfigEntry OBJECT-TYPE
|
|
SYNTAX SlSonetConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the table. There is an entry for each SONET line
|
|
in the table. Entries are automatically created for an
|
|
ifType value of sonet(39). 'ifAdminStatus' from the ifTable
|
|
must be used to enable or disable a line. By default, the
|
|
line state is down."
|
|
INDEX { ifIndex }
|
|
::= { slSonetConfigTable 1 }
|
|
|
|
SlSonetConfigEntry ::=
|
|
SEQUENCE {
|
|
slSonetConfigFrameScramble INTEGER,
|
|
slSonetConfigType INTEGER, -- deprecated
|
|
slSonetConfigDccSelection INTEGER,
|
|
slSonetResetAllCounters INTEGER,
|
|
slSonetPortThresholdTrapEnable INTEGER,
|
|
slSonetConfigSdThreshold INTEGER,
|
|
slSonetConfigSfThreshold INTEGER,
|
|
slSonetCompression INTEGER,
|
|
slSonetOverheadTunneling INTEGER,
|
|
slSonetLopBitmask Counter64, -- deprecated
|
|
slSonetTdmTrunk TruthValue,
|
|
slSonetFsApply INTEGER, -- deprecated
|
|
slSonetTxLte INTEGER,
|
|
slSonetReceivedLte INTEGER,
|
|
slSonetResetPmThreshold INTEGER,
|
|
slSonetResetAlsParams INTEGER,
|
|
slSonetTransceiverType INTEGER,
|
|
slSonetTransceiverMedia INTEGER
|
|
}
|
|
|
|
slSonetConfigFrameScramble OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to disable or enable the Scrambling
|
|
option in SONET line. Please refer to GR-253-CORE for
|
|
frame scrambling."
|
|
REFERENCE
|
|
"GR-253-CORE"
|
|
DEFVAL { enabled }
|
|
::= {slSonetConfigEntry 1}
|
|
|
|
slSonetConfigType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sonetSts3(1), -- deprecated
|
|
sonetSts3c(2), -- deprecated
|
|
sonetSts12(3), -- deprecated
|
|
sonetSts12c(4), -- deprecated
|
|
sonetSts48c(5),
|
|
sonetSts3cx4(6), -- deprecated
|
|
sonetSts48(7), -- deprecated
|
|
sonetSts3cx16(8), -- deprecated
|
|
sonetSts3x16(9), -- deprecated
|
|
sonetSts12cx4(10), -- deprecated
|
|
sonetSts12x4(11), -- deprecated
|
|
sonetSts192c(12),
|
|
sonetStsOther(13)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the configured line type for Trunks:
|
|
sonetSts48c(5) - 1 x Sts48 (2.5GbTrunk)
|
|
sonetSts192c(12) - 1 x Sts192 (10Gb Trunk)
|
|
sonetStsOther(13) - for OC-n interfaces see slSonetFsTable."
|
|
::= {slSonetConfigEntry 2}
|
|
|
|
slSonetConfigDccSelection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sonetLineDcc(1),
|
|
sonetSectionDcc(2),
|
|
sonetInband(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object selects the DCC type."
|
|
::= {slSonetConfigEntry 3 }
|
|
|
|
slSonetResetAllCounters OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
resetCounters(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this variable to 1 will cause all of the counters
|
|
(performance regsters) on this SONET interface to be initialized
|
|
to zero (0)."
|
|
REFERENCE "ANSI T1.231-1997 clause 9.1.5.1."
|
|
::= { slSonetConfigEntry 4 }
|
|
|
|
slSonetPortThresholdTrapEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { enabled(1), disabled(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates whether threshold traps
|
|
should be generated for this SONET interface."
|
|
REFERENCE "ANSI T1.231-1997 clause 9.1.5.2."
|
|
DEFVAL { disabled }
|
|
::= { slSonetConfigEntry 5 }
|
|
|
|
slSonetConfigSdThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (5..9)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the Bit Error Rate threshold for
|
|
Signal Degrade detection on the working line. Once this
|
|
threshold is exceeded, an APS switch will occur.
|
|
This value is 10 to -n where n is between 5 and 9
|
|
(read-write)."
|
|
DEFVAL {5}
|
|
::= { slSonetConfigEntry 6 }
|
|
|
|
slSonetConfigSfThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (3..5)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the Bit Error Rate threshold for
|
|
Signal Fault detection on the working line. Once this
|
|
threshold is exceeded, an APS switch will occur.
|
|
This value is 10 to the -n, where n is between 3 and 5.
|
|
(read-write)"
|
|
DEFVAL {3}
|
|
::= { slSonetConfigEntry 7 }
|
|
|
|
slSonetCompression OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uncompress(0),
|
|
posCompress32(1),
|
|
posCompress16(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object applies only for trunk ports.
|
|
It specifies if the packets should be compressed.
|
|
0 - Means no POS compression,
|
|
1 - Means POS compression with CRC-32.
|
|
2 - Means POS compression with CRC-16.
|
|
Note that the two connected trunks should be configured
|
|
to the same value.
|
|
Note also that the BW calculation of the OC-n should
|
|
be changed according to this value."
|
|
::= { slSonetConfigEntry 9 }
|
|
|
|
slSonetOverheadTunneling OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
lineDcc(1),
|
|
k1k2(2),
|
|
full(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The section and line overhead tunneling configuration:
|
|
none(0) - no tunneling support
|
|
lineDcc(1) - line DCC tunneling
|
|
k1k2(2) - line DCC + protection k byte
|
|
full(3) - all transport overhead bytes are tunneled"
|
|
::= { slSonetConfigEntry 10 }
|
|
|
|
slSonetLopBitmask OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current -- deprecated
|
|
DESCRIPTION
|
|
"The LOP status. Each bit of the bits represent the status
|
|
of the LOP alarm in corresponding STS.
|
|
For a path with more than a single STS, only the value of the
|
|
first STS in the path is relevant.
|
|
This object is relevant only for the OC-N cards and not
|
|
for the Trunk.
|
|
In the next future this object will be replaced with
|
|
an object of a new table that shall describe the OC-N
|
|
frame structure."
|
|
::= { slSonetConfigEntry 11 }
|
|
|
|
slSonetTdmTrunk OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is applicable only to the OC-n ports.
|
|
TRUE - means that the OC-n port is used as a TDM Trunk.
|
|
FLASE - means normal OC-n port."
|
|
::= { slSonetConfigEntry 12 }
|
|
|
|
slSonetFsApply OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write -- deprecated
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing to this object activate the slSonetFsTable setting.
|
|
This allow the NMS to do many changes to the slSonetFsTable
|
|
and then APPLY them at once. This prevent from going through
|
|
unconsistent steps.
|
|
This object always returns the value 0."
|
|
::= { slSonetConfigEntry 13 }
|
|
|
|
slSonetTxLte OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ssb00(1), -- SONET
|
|
ssb10(2), -- SDH
|
|
auto(5) -- Tx what is detected
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SS bits to transmit (bits 5,6 in H1,H1*)."
|
|
::= { slSonetConfigEntry 14 }
|
|
|
|
slSonetReceivedLte OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ssb00(1), -- SONET
|
|
ssb10(2), -- SDH
|
|
ssb01(3), -- other
|
|
ssb11(4), -- other
|
|
ssbinv(5) -- invalid
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The detected LTE type, according to the received SS bits
|
|
(bits 5,6 in H1,H1*)."
|
|
::= { slSonetConfigEntry 15 }
|
|
|
|
slSonetResetPmThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
resetCounters(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this variable to 1 will reset the PM threshold
|
|
parameters to the factory defaults."
|
|
REFERENCE "ANSI T1.231-1997 clause 9.1.5.1."
|
|
::= { slSonetConfigEntry 16 }
|
|
|
|
slSonetResetAlsParams OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
resetCounters(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this variable to 1 will reset the ALS
|
|
parameters to the factory defaults."
|
|
REFERENCE "ANSI T1.231-1997 clause 9.1.5.1."
|
|
::= { slSonetConfigEntry 17 }
|
|
|
|
slSonetTransceiverType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
shortWave(2), -- 850nm
|
|
longWave(3) -- 1310nm
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tranceiver type."
|
|
::= { slSonetConfigEntry 18 }
|
|
|
|
slSonetTransceiverMedia OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1), --
|
|
sm(2), -- Single Mode
|
|
mm(3) -- Multi Mode
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tranceiver media."
|
|
::= { slSonetConfigEntry 19 }
|
|
|
|
|
|
-- ----------------------------------------------------------------
|
|
--
|
|
-- Sonet Trace Table
|
|
--
|
|
-- ----------------------------------------------------------------
|
|
|
|
slSonetTraceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SlSonetTraceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SONET/SDH Trace table. This table contains
|
|
objects for tracing the sonet section and path."
|
|
::= { slSonetOhTrace 1 }
|
|
|
|
slSonetTraceEntry OBJECT-TYPE
|
|
SYNTAX SlSonetTraceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the trace table. Entries exist for active sonet
|
|
interfaces. The objects in this table are used to verify
|
|
continued connection between the two ends of the line."
|
|
INDEX { ifIndex }
|
|
::= { slSonetTraceTable 1 }
|
|
|
|
|
|
SlSonetTraceEntry ::=
|
|
SEQUENCE {
|
|
slSonetTraceMode INTEGER,
|
|
slSonetTraceToTransmit DisplayString,
|
|
slSonetTraceToExpect DisplayString,
|
|
slSonetTraceFailure TruthValue,
|
|
slSonetTraceReceived DisplayString
|
|
}
|
|
|
|
slSonetTraceMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1), -- notification and rdi
|
|
disable(2), -- no notification and no rdi
|
|
monitoring(3) -- only notification and no rdi
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determine the Trace Message Mode."
|
|
REFERENCE
|
|
"GR-253-CORE"
|
|
::= { slSonetTraceEntry 1 }
|
|
|
|
slSonetTraceToTransmit OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..62))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sonet Trace To Transmit. This is string that
|
|
is transmitted to perform Sonet trace
|
|
diagnostics. The trace string is repetitively
|
|
transmited so that a trace receiving terminal can
|
|
verify its continued connection to the intended
|
|
transmitter. The default value is a zero-length string.
|
|
Unless this object is set to a non-zero length string,
|
|
tracing will not be performed.
|
|
The Agent is responsible to pad the end of the string with <CR><LF>."
|
|
REFERENCE
|
|
"GR-253-CORE"
|
|
::= { slSonetTraceEntry 2 }
|
|
|
|
slSonetTraceToExpect OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..62))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sonet Trace Massage To Expect. The receiving terminal
|
|
verifies if the incoming string matches this string.
|
|
The value of 'slSonetTraceFailure' indicates whether a
|
|
trace mismatch occurred. The default value is a
|
|
zero-length string.
|
|
The Agent is responsible to pad the end of the string with <CR><LF>."
|
|
REFERENCE
|
|
"GR-253-CORE"
|
|
::= { slSonetTraceEntry 3 }
|
|
|
|
slSonetTraceFailure OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is set to 'true' when Sonet
|
|
Section received trace does not match the
|
|
'slSonetTraceToExpect'."
|
|
REFERENCE
|
|
"GR-253-CORE"
|
|
::= { slSonetTraceEntry 4 }
|
|
|
|
slSonetTraceReceived OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..62))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to view the Sonet Trace Message that
|
|
is received by the receiving terminal.
|
|
The Agent is responsible to pad the end of the string with <CR><LF>."
|
|
REFERENCE
|
|
"GR-253-CORE"
|
|
::= { slSonetTraceEntry 5 }
|
|
|
|
|
|
-- ----------------------------------------------------------------
|
|
--
|
|
-- Signal Label Table
|
|
--
|
|
-- ----------------------------------------------------------------
|
|
|
|
slSonetSlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SlSonetSlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SONET/SDH Signal Label table. This table contains
|
|
signal label for the sonet path."
|
|
::= { slSonetOhSl 1 }
|
|
|
|
slSonetSlEntry OBJECT-TYPE
|
|
SYNTAX SlSonetSlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the SONET/SDH Signal Label table. The entries
|
|
exist for active sonet lines. The objects in this table are
|
|
used to verify continued connection between the two ends of
|
|
the line."
|
|
INDEX { ifIndex }
|
|
::= { slSonetSlTable 1 }
|
|
|
|
|
|
SlSonetSlEntry ::=
|
|
SEQUENCE {
|
|
slSonetSlToTransmit SignalLabel,
|
|
slSonetSlToExpect SignalLabel,
|
|
slSonetSlFailure TruthValue,
|
|
slSonetSlReceived INTEGER
|
|
}
|
|
|
|
slSonetSlToTransmit OBJECT-TYPE
|
|
SYNTAX SignalLabel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sonet Signal Label To Transmit."
|
|
REFERENCE
|
|
"GR-253-CORE"
|
|
::= { slSonetSlEntry 2 }
|
|
|
|
slSonetSlToExpect OBJECT-TYPE
|
|
SYNTAX SignalLabel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sonet Signal Label To Expect."
|
|
REFERENCE
|
|
"GR-253-CORE"
|
|
::= { slSonetSlEntry 3 }
|
|
|
|
slSonetSlFailure OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object is set to 'true' when Sonet
|
|
received signal label does not match the 'slSonetSlToExpect'."
|
|
REFERENCE
|
|
"GR-253-CORE"
|
|
::= { slSonetSlEntry 4 }
|
|
|
|
slSonetSlReceived OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to view the Sonet Signal Label that is
|
|
received by the receiving terminal."
|
|
REFERENCE
|
|
"GR-253-CORE"
|
|
::= { slSonetSlEntry 5 }
|
|
|
|
-- ----------------------------------------------------------------
|
|
--
|
|
-- Packets Over Sonet/Sdh (POS) Performance Monitoring (PM) Table
|
|
--
|
|
-- ----------------------------------------------------------------
|
|
|
|
slSonetPosTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SlSonetPosEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The POS PM Table."
|
|
::= { slSonetPos 1 }
|
|
|
|
slSonetPosEntry OBJECT-TYPE
|
|
SYNTAX SlSonetPosEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entries exist for active Trunk sonet lines
|
|
ifType = pos(171). The objects in this table are
|
|
used to moitor the POS layer."
|
|
INDEX { ifIndex }
|
|
::= { slSonetPosTable 1 }
|
|
|
|
SlSonetPosEntry ::=
|
|
SEQUENCE {
|
|
slSonetPosFcs Gauge32,
|
|
slSonetPosAbort Gauge32,
|
|
slSonetPosMinViolation Gauge32,
|
|
slSonetPosMaxViolation Gauge32,
|
|
slSonetPosRxfifoDiscard Gauge32,
|
|
slSonetPosPacketReceived Counter64,
|
|
slSonetPosPacketReceivedOk Counter64
|
|
}
|
|
|
|
slSonetPosFcs OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Number of FCS Errors."
|
|
::= { slSonetPosEntry 1 }
|
|
|
|
slSonetPosAbort OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Number of Aborted packets."
|
|
::= { slSonetPosEntry 2 }
|
|
|
|
slSonetPosMinViolation OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Number of Minimum length violation packets."
|
|
::= { slSonetPosEntry 3 }
|
|
|
|
slSonetPosMaxViolation OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Number of Maximum length violation packets."
|
|
::= { slSonetPosEntry 4 }
|
|
|
|
slSonetPosRxfifoDiscard OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Number of packets discarded due to RXFIFO error."
|
|
::= { slSonetPosEntry 5 }
|
|
|
|
slSonetPosPacketReceived OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Number of packets received."
|
|
::= { slSonetPosEntry 6 }
|
|
|
|
slSonetPosPacketReceivedOk OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Number of error free packets."
|
|
::= { slSonetPosEntry 7 }
|
|
|
|
|
|
-- ----------------------------------------------------------------
|
|
--
|
|
-- Automatic Laser Shutdown (ALS) Configuration Table
|
|
--
|
|
-- ----------------------------------------------------------------
|
|
|
|
slSonetAlsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SlSonetAlsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ALS configuration Table."
|
|
::= { slSonetAls 1 }
|
|
|
|
slSonetAlsEntry OBJECT-TYPE
|
|
SYNTAX SlSonetAlsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entries exist for active sonet lines
|
|
ifType = sonet(39). The objects in this table are
|
|
used to configure the ALS algorithm."
|
|
INDEX { ifIndex }
|
|
::= { slSonetAlsTable 1 }
|
|
|
|
SlSonetAlsEntry ::=
|
|
SEQUENCE {
|
|
slSonetAlsMode INTEGER,
|
|
slSonetLosDeclareTime INTEGER,
|
|
slSonetTestPulseTime INTEGER,
|
|
slSonetManualPulseTime INTEGER,
|
|
slSonetAutomaticPulseTime INTEGER,
|
|
slSonetAutomaticDelayTime INTEGER,
|
|
slSonetLaserTestActivate INTEGER,
|
|
slSonetLaserManualActivate INTEGER
|
|
}
|
|
|
|
slSonetAlsMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable the ALS algorithm.
|
|
Note that the if the Laser Admin Status is 'down' the
|
|
ALS mechanism is not operational."
|
|
::= { slSonetAlsEntry 1 }
|
|
|
|
slSonetLosDeclareTime OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ms500(1), -- 500 ms
|
|
ms550(2), -- 550 ms
|
|
ms600(3) -- 600 ms
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time to declare optical LOS present or clear: 550 +- 50 msec."
|
|
::= { slSonetAlsEntry 2 }
|
|
|
|
slSonetTestPulseTime OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
s80(1), -- 80 sec
|
|
s90(2), -- 90 sec
|
|
s100(3) -- 100 sec
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manual restart for test Pulse time (in manual restart) - 90+-10 sec."
|
|
::= { slSonetAlsEntry 3 }
|
|
|
|
slSonetManualPulseTime OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ms1750(1), -- 1.75 Sec
|
|
ms2000(2), -- 2.0 sec
|
|
ms2250(3) -- 2.25 sec
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manual restart Pulse time (in manual mode) - 2+-0.25 sec."
|
|
::= { slSonetAlsEntry 4 }
|
|
|
|
slSonetAutomaticPulseTime OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ms1750(1), -- 1.75 Sec
|
|
ms2000(2), -- 2.0 sec
|
|
ms2250(3) -- 2.25 sec
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatic restart Pulse time (in automatic mode) - 2+-0.25 sec."
|
|
::= { slSonetAlsEntry 5 }
|
|
|
|
slSonetAutomaticDelayTime OBJECT-TYPE
|
|
SYNTAX INTEGER (60..300)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In Automatic mode. The delay between two laser re-activations."
|
|
::= { slSonetAlsEntry 6 }
|
|
|
|
slSonetLaserTestActivate OBJECT-TYPE
|
|
SYNTAX INTEGER { activate(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Activate the laser for test operation."
|
|
::= { slSonetAlsEntry 7 }
|
|
|
|
slSonetLaserManualActivate OBJECT-TYPE
|
|
SYNTAX INTEGER { activate(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Activate the laser manual operation."
|
|
::= { slSonetAlsEntry 8 }
|
|
|
|
-- ----------------------------------------------------------------
|
|
--
|
|
-- Frame Structure Configuration Table
|
|
--
|
|
-- ----------------------------------------------------------------
|
|
|
|
slSonetFsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SlSonetFsEntry
|
|
MAX-ACCESS not-accessible -- deprecated
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The frame structure configuration Table.
|
|
In order to define a new path the NMS should create and configure
|
|
an entry in this table.
|
|
The table is also used to monitor the status of the LOP
|
|
alarm per path."
|
|
::= { slSonetFs 1 }
|
|
|
|
slSonetFsEntry OBJECT-TYPE
|
|
SYNTAX SlSonetFsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entries exist for sonet paths
|
|
ifType = sonet(39). The objects in this table are
|
|
used to configure the frame structure.
|
|
Each OC-N line interface shall maintain a static
|
|
table with number of lines equal to the N.
|
|
Initially the table will be initialized to STS-Nc."
|
|
INDEX { slSonetFsIfIndex,
|
|
slSonetFsSts }
|
|
::= { slSonetFsTable 1 }
|
|
|
|
SlSonetFsEntry ::=
|
|
SEQUENCE {
|
|
slSonetFsIfIndex InterfaceIndex,
|
|
slSonetFsSts INTEGER,
|
|
slSonetFsWidth INTEGER,
|
|
slSonetFsFullPathTermination TruthValue,
|
|
slSonetFsGranularity INTEGER
|
|
}
|
|
|
|
slSonetFsIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface index."
|
|
::= { slSonetFsEntry 1 }
|
|
|
|
slSonetFsSts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of the first STS in the path.
|
|
Note that no all values are legal because there is no
|
|
support for combus with mixed structure"
|
|
::= { slSonetFsEntry 2 }
|
|
|
|
slSonetFsWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number STS's in the path.
|
|
The width is only valid for the first STS in the path.
|
|
The other STSs of the path will have width=0."
|
|
::= { slSonetFsEntry 3 }
|
|
|
|
slSonetFsFullPathTermination OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FALSE - means partial path termination (only LOP alarm).
|
|
TRUE - include full support for path Alarms and PM counters."
|
|
::= { slSonetFsEntry 4 }
|
|
|
|
slSonetFsGranularity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
vc4(1),
|
|
vc3(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is set by the NMS according to the configured frame structure.
|
|
Each VC-3 that is mapped to AUG-1 via VC-4 should have the value vc4(1).
|
|
Otherwise the value should be vc3(2)."
|
|
::= { slSonetFsEntry 5 }
|
|
|
|
-- ----------------------------------------------------------------
|
|
--
|
|
-- Sonet Traps
|
|
--
|
|
-- ----------------------------------------------------------------
|
|
|
|
slSonetFsTableChange NOTIFICATION-TYPE
|
|
OBJECTS { slSonetFsIfIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A slSonetFsTableChange trap is sent when the
|
|
content of the slSonetFsTable is changed.
|
|
This trap may be used by the NMS to identify
|
|
the removal of path interfaces, or addition of
|
|
new path interfaces"
|
|
::= { slSonetTraps 1 }
|
|
|
|
|
|
END
|
|
|
|
|
|
|