428 lines
12 KiB
Plaintext
428 lines
12 KiB
Plaintext
-- File Name : PBI-MGSIGNALCHARACTERISTICS-MIB
|
|
-- Date : Thu Sep 21 14:37:54 CST 2006
|
|
-- Author : AdventNet Agent Toolkit Java Edition - MIB Editor 6
|
|
|
|
|
|
|
|
PBI-MGSIGNALCHARACTERISTICS-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
RowStatus, DisplayString
|
|
FROM SNMPv2-TC
|
|
DisplayString
|
|
FROM RFC1213-MIB
|
|
mg
|
|
FROM PBI-MAIN-MIB
|
|
MODULE-IDENTITY, enterprises, OBJECT-TYPE, Integer32
|
|
FROM SNMPv2-SMI;
|
|
|
|
mgSignalCharacteristics MODULE-IDENTITY
|
|
LAST-UPDATED "200609210924Z"
|
|
ORGANIZATION "Organization"
|
|
CONTACT-INFO "Contact-info"
|
|
DESCRIPTION "Description"
|
|
REVISION "200609210924Z"
|
|
DESCRIPTION ""
|
|
::= { mg 2 }
|
|
|
|
tsOutTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TsOutEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " "
|
|
::= { mgSignalCharacteristics 1 }
|
|
|
|
mgPATTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MgPATEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "PSI/SI information relating to the PAT, reference ISO/IEC 13818-1 "
|
|
::= { mgSignalCharacteristics 2 }
|
|
|
|
mgPMTTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MgPMTEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "PSI/SI information relating to the PMT"
|
|
::= { mgSignalCharacteristics 3 }
|
|
|
|
mgNITTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MgNITEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "PSI/SI information relating to the NIT"
|
|
::= { mgSignalCharacteristics 4 }
|
|
|
|
mgSDTTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MgSDTEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "PSI/SI information relating to the SDT, reference DVB 300-468"
|
|
::= { mgSignalCharacteristics 5 }
|
|
|
|
mgFilterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MgFilterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Description"
|
|
::= { mgSignalCharacteristics 6 }
|
|
|
|
mgCATTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MgCATEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "PSI/SI information relating to the CAT, reference ISO/IEC 13818-1 "
|
|
::= { mgSignalCharacteristics 7 }
|
|
|
|
tsInput OBJECT IDENTIFIER
|
|
::= { mgSignalCharacteristics 8 }
|
|
|
|
mgBATTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MgBATEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " PSI/SI information relating to the BAT, reference ISO/IEC 13818-1 "
|
|
::= { mgSignalCharacteristics 9 }
|
|
|
|
tsOutEntry OBJECT-TYPE
|
|
SYNTAX TsOutEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " Row Description "
|
|
INDEX { channelOutput }
|
|
::= { tsOutTable 1 }
|
|
|
|
TsOutEntry ::= SEQUENCE {
|
|
channelOutput INTEGER,
|
|
bitRate INTEGER,
|
|
packetSize INTEGER,
|
|
transportStreamID INTEGER,
|
|
otiginalNetworkID INTEGER,
|
|
networkID INTEGER,
|
|
bitrateThreshosdPercent INTEGER,
|
|
outValidBitRate INTEGER
|
|
}
|
|
|
|
channelOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "output channel number"
|
|
::= { tsOutEntry 1 }
|
|
|
|
bitRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Transport stream output size, 3000EC: from 0 to 16Mpbs; 3000MX:from 0 to 100Mpbs; 3000TM: from 0 to 50Mpbs"
|
|
::= { tsOutEntry 2 }
|
|
|
|
packetSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Packet length, option: 188 or 204"
|
|
::= { tsOutEntry 3 }
|
|
|
|
transportStreamID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The transport stream ID for this transport stream as read from the PAT, its value range: reference ISO/IEC 13818-1"
|
|
::= { tsOutEntry 4 }
|
|
|
|
otiginalNetworkID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The original network ID for this transport stream as read from the NIT, its value range: reference DVB 300-468"
|
|
::= { tsOutEntry 5 }
|
|
|
|
networkID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The network ID for this transport stream as read from the NIT, its value range: reference DVB 300-468"
|
|
::= { tsOutEntry 6 }
|
|
|
|
bitrateThreshosdPercent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "ts overflow percent value(0 - 100)"
|
|
::= { tsOutEntry 7 }
|
|
|
|
outValidBitRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "transport stream out valid bit rate"
|
|
::= { tsOutEntry 8 }
|
|
|
|
mgPATEntry OBJECT-TYPE
|
|
SYNTAX MgPATEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Row Description"
|
|
INDEX { channelInputPAT }
|
|
::= { mgPATTable 1 }
|
|
|
|
MgPATEntry ::= SEQUENCE {
|
|
channelInputPAT INTEGER,
|
|
patSection DisplayString
|
|
}
|
|
|
|
channelInputPAT OBJECT-TYPE
|
|
SYNTAX INTEGER ( -2147483648 .. 2147483647 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The physical input on which this transport stream appears"
|
|
::= { mgPATEntry 1 }
|
|
|
|
patSection OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The transport stream Relating to the PAT seciton, reference ISO/IEC 13818-1 "
|
|
::= { mgPATEntry 2 }
|
|
|
|
mgPMTEntry OBJECT-TYPE
|
|
SYNTAX MgPMTEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Row Description"
|
|
INDEX { channelInputPMT }
|
|
::= { mgPMTTable 1 }
|
|
|
|
MgPMTEntry ::= SEQUENCE {
|
|
channelInputPMT INTEGER,
|
|
pmtProgramNumber INTEGER,
|
|
pmtPID INTEGER,
|
|
pmtSection DisplayString
|
|
}
|
|
|
|
channelInputPMT OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The physical input on which this transport stream appears"
|
|
::= { mgPMTEntry 1 }
|
|
|
|
pmtProgramNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The PMT program number as read from PMT,reference ISO/IEC 13818-1"
|
|
::= { mgPMTEntry 2 }
|
|
|
|
pmtPID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The PMT PID as read from PMT,reference ISO/IEC 13818-1"
|
|
::= { mgPMTEntry 3 }
|
|
|
|
pmtSection OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The transport stream Relating to the PMT seciton, reference ISO/IEC 13818-1"
|
|
::= { mgPMTEntry 4 }
|
|
|
|
mgNITEntry OBJECT-TYPE
|
|
SYNTAX MgNITEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Row Description"
|
|
INDEX { channelInputNIT }
|
|
::= { mgNITTable 1 }
|
|
|
|
MgNITEntry ::= SEQUENCE {
|
|
channelInputNIT INTEGER,
|
|
networkType INTEGER,
|
|
nitActualSection DisplayString,
|
|
nitOhtersSection DisplayString
|
|
}
|
|
|
|
channelInputNIT OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The physical input on which this transport stream appears"
|
|
::= { mgNITEntry 1 }
|
|
|
|
networkType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The network type include two types: actual NIT and others NIT, reference DVB 300-468"
|
|
::= { mgNITEntry 2 }
|
|
|
|
nitActualSection OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Relating to the Actual section, its table ID is 0x40 in NIT,reference DVB 300-468"
|
|
::= { mgNITEntry 3 }
|
|
|
|
nitOhtersSection OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Relating to the others section , its table ID is 0x41 in NIT,reference DVB 300-468"
|
|
::= { mgNITEntry 4 }
|
|
|
|
mgSDTEntry OBJECT-TYPE
|
|
SYNTAX MgSDTEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Row Description"
|
|
INDEX { channelInputSDT }
|
|
::= { mgSDTTable 1 }
|
|
|
|
MgSDTEntry ::= SEQUENCE {
|
|
channelInputSDT INTEGER,
|
|
sdtSection DisplayString
|
|
}
|
|
|
|
channelInputSDT OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The physical input on which this transport stream appears"
|
|
::= { mgSDTEntry 1 }
|
|
|
|
sdtSection OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The transport stream relating to SDT seciton, reference DVB 300-468"
|
|
::= { mgSDTEntry 2 }
|
|
|
|
mgFilterEntry OBJECT-TYPE
|
|
SYNTAX MgFilterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Row Description"
|
|
INDEX { channelInputFilter }
|
|
::= { mgFilterTable 1 }
|
|
|
|
MgFilterEntry ::= SEQUENCE {
|
|
channelInputFilter INTEGER,
|
|
oldPID DisplayString,
|
|
newPID DisplayString,
|
|
oldProgramNumber DisplayString,
|
|
newProgramNumber DisplayString
|
|
}
|
|
|
|
channelInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The physical input on which this transport stream appears"
|
|
::= { mgFilterEntry 1 }
|
|
|
|
oldPID OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The old PID will be filtered output"
|
|
::= { mgFilterEntry 2 }
|
|
|
|
newPID OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The new PID is bulit according to old PID"
|
|
::= { mgFilterEntry 3 }
|
|
|
|
oldProgramNumber OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The old program number,they come from PAT and will be filtered output"
|
|
::= { mgFilterEntry 4 }
|
|
|
|
newProgramNumber OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The new program number, they are bulit and will be made a new PAT"
|
|
::= { mgFilterEntry 5 }
|
|
|
|
mgCATEntry OBJECT-TYPE
|
|
SYNTAX MgCATEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Row Description"
|
|
INDEX { channelInputCAT }
|
|
::= { mgCATTable 1 }
|
|
|
|
MgCATEntry ::= SEQUENCE {
|
|
channelInputCAT INTEGER,
|
|
catSection DisplayString
|
|
}
|
|
|
|
channelInputCAT OBJECT-TYPE
|
|
SYNTAX INTEGER ( -2147483648 .. 2147483647 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The physical input on which this transport stream appears"
|
|
::= { mgCATEntry 1 }
|
|
|
|
catSection OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The transport stream Relating to the CAT seciton, reference ISO/IEC 13818-1 "
|
|
::= { mgCATEntry 2 }
|
|
|
|
channelInput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "channel number of input"
|
|
::= { tsInput 1 }
|
|
|
|
stateLock OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "0xFFFF is lock, other is unlock"
|
|
::= { tsInput 2 }
|
|
|
|
tsIdPreference OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "transport stream identifier"
|
|
::= { tsInput 3 }
|
|
|
|
mgBATEntry OBJECT-TYPE
|
|
SYNTAX MgBATEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Row Description"
|
|
INDEX { channelBAT }
|
|
::= { mgBATTable 1 }
|
|
|
|
MgBATEntry ::= SEQUENCE {
|
|
channelBAT INTEGER,
|
|
batSection DisplayString
|
|
}
|
|
|
|
channelBAT OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "specify channel of get BAT "
|
|
::= { mgBATEntry 1 }
|
|
|
|
batSection OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The transport stream Relating to the BAT seciton, reference ISO/IEC 13818-1 "
|
|
::= { mgBATEntry 2 }
|
|
|
|
END
|