PEGASUS-SDH-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
Integer32,
|
|
OBJECT-TYPE,
|
|
MODULE-IDENTITY FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION,
|
|
DisplayString,
|
|
TruthValue FROM SNMPv2-TC
|
|
InterfaceIndex,
|
|
InterfaceIndexOrZero,
|
|
ifIndex FROM IF-MIB
|
|
pegasusMibModule,
|
|
OperStateEnum,
|
|
AvailabilityStatusElem,
|
|
CommStateEnum FROM PEGASUS-MIB;
|
|
|
|
pegasusSdhMibModule MODULE-IDENTITY
|
|
LAST-UPDATED "200403180000Z" -- 18 March, 2004
|
|
ORGANIZATION "Schmid Telecom, Zurich"
|
|
CONTACT-INFO
|
|
"Schmid Telecom AG
|
|
Binzstrasse 35, CH-8048 Zurich
|
|
Switzerland
|
|
|
|
Email: xdslsupport@schmid-telecom.ch"
|
|
DESCRIPTION
|
|
"This MIB applies to the PEGASUS SDSL product manufactured by Schmid
|
|
Telecom Zurich. The MIB is modelled after the PEM management model, so
|
|
object hierarchy and individual variables agree with the PEM client. This
|
|
MIB represents an extension to the DS1-MIB and the SONET-MIB. These three
|
|
MIB files are used to manage the PEGASUS STM-1 card.
|
|
|
|
The PEGASUS-SDH-MIB contains five tables:
|
|
- stm1CardTable one entry for each STM-1 card configured.
|
|
- stm1CardClockTable one entry for each STM-1 card configured.
|
|
- ethernetIfTable one entry for each Ethernet interface of a
|
|
configured STM-1 card.
|
|
- vcTable one entry for each Virtual Container (VC-3/4/12).
|
|
- tugConfigTable one entry for each Tributary Unit Group (TUG-3).
|
|
|
|
Note
|
|
- The tables that represent extensions to the DS1-/SINET-MIB use the
|
|
ifIndex from IF-MIB (ifTable)."
|
|
|
|
REVISION "200403180000Z" -- 18 March, 2004
|
|
DESCRIPTION
|
|
"Improved Alarm signalisation. A new variable stm1CardAlarmStatus shows
|
|
the alarms that are active on the STM-1 card. Active Ethernet alarms are
|
|
shown by ethernetIfAlarmStatus. The following values for vcAlarmStatus
|
|
are can not occur (not used):
|
|
- vcgTxAddTimeout - vcgDnuOk
|
|
- vcgTxAdd - vcgRxAdd
|
|
- vcgTxRemove - vcgRxRemove
|
|
- vcgTxDnu - vcgRxFail"
|
|
REVISION "200401070000Z" -- 7 January, 2004
|
|
DESCRIPTION
|
|
"Actually, only GFP is supported as Ethernet Encapsulation. Therefore
|
|
the variable etherIfEncapsulation is now read-only."
|
|
REVISION "200311170000Z" -- 17 November, 2003
|
|
DESCRIPTION
|
|
"Initial Revision."
|
|
::= { pegasusMibModule 8 }
|
|
|
|
|
|
-- *******************************************************************
|
|
-- stm1 card group
|
|
--
|
|
-- This group contains four tables:
|
|
-- - stm1CardTable
|
|
-- - ethernetIfTable
|
|
-- - vcConfigTable
|
|
-- - tugConfigTable
|
|
-- *******************************************************************
|
|
-- STM1 Card Enumerations and Subranges
|
|
|
|
ClockSourceEnum ::= INTEGER {
|
|
rxLineClock(1),
|
|
referenceClock(2),
|
|
freeRun(3)
|
|
}
|
|
|
|
ClockSyncStateEnum ::= INTEGER {
|
|
syncOk(1),
|
|
syncNotOk(2)
|
|
}
|
|
|
|
ClockModeEnum ::= INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
|
|
ClockPriorityEnum ::= INTEGER {
|
|
primary(1),
|
|
secondary(2)
|
|
}
|
|
|
|
ClockQualityEnum ::= INTEGER {
|
|
prc(1),
|
|
ssu-a(2),
|
|
ssu-b(3),
|
|
sec(4),
|
|
dnu(5),
|
|
auto(6),
|
|
unknown(7)
|
|
}
|
|
|
|
ClockStateEnum ::= INTEGER {
|
|
invalid(1),
|
|
valid(2)
|
|
}
|
|
|
|
MultiplexingModeEnum ::= INTEGER {
|
|
au3(1),
|
|
au4(2)
|
|
}
|
|
|
|
VirtualContainerTypeEnum ::= INTEGER {
|
|
vc4(1),
|
|
vc3(2),
|
|
vc12(3)
|
|
}
|
|
|
|
LaserOperationModeEnum ::= INTEGER {
|
|
off(1),
|
|
als(2)
|
|
}
|
|
|
|
LaserStateEnum ::= INTEGER {
|
|
on(1),
|
|
shutdown(2),
|
|
restart(3)
|
|
}
|
|
|
|
SdhInterfaceEnum ::= INTEGER {
|
|
optical(1),
|
|
e1(2)
|
|
}
|
|
|
|
PRBSPatternEnum ::= INTEGER {
|
|
pattern2exp15(1), -- 2^15-1 = 32767
|
|
pattern2exp20(2) -- 2^20-1 = 1048575
|
|
}
|
|
|
|
TraceSizeEnum ::= INTEGER {
|
|
size1byte(1),
|
|
size16byte(2)
|
|
}
|
|
|
|
SignalLabel ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "x"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Representation of a VC Signal Label. The meaning of the SignalLabel
|
|
depends on the type of vitual container.
|
|
VC-12s use the following values:
|
|
001b Unequipped
|
|
001b Equipped (non specific)
|
|
010b Asynchronous
|
|
011b Bit Synchronous
|
|
100b Byte Synchronous
|
|
101b Reserved for future use
|
|
110b Test signal (O.181)
|
|
111b VC-AIS
|
|
|
|
VC-4 and VC-3 use these values:
|
|
00h Unequipped or supervisory-unequipped
|
|
01h Equipped - non-specific
|
|
02h TUG Structure
|
|
03h Locked TU-n
|
|
04h Asynch. mapping of 34'386/44'736 kbit/s into Container-3
|
|
12h Asynch. mapping of 139'264 kbit/s into Container-4
|
|
13h ATM Mapping
|
|
14h MAN DQDB (IEEE 802.6 mapping
|
|
15h FDDI (ISO 9314) mapping
|
|
16h Mapping of HDLC/PPP framed signal
|
|
17h Mapping of SDL with SDH self synch. Scrambler
|
|
18h Mapping of HDLC/LAP-S framed signals
|
|
19h Mapping of SDL with set-reset scrambler
|
|
1Ah Mapping of 10 Gbit/s Ethernet frames (IEEE 802.3)
|
|
CFh Obsolete mapping of HDLC/PPP framed signal
|
|
E1h-FCh Reserved for national use
|
|
FEh Test signal, O.181 specific mapping
|
|
FFh VC-AIS"
|
|
SYNTAX INTEGER(0..7|18..26|207|225..252|254..255)
|
|
|
|
ConcatenationTypeEnum ::= INTEGER {
|
|
lcas(1),
|
|
nonLCAS(2)
|
|
}
|
|
|
|
EthernetIfEncapsulationEnum ::= INTEGER {
|
|
disabled(1), -- not supported feature
|
|
gfp(2),
|
|
lapf(3), -- not supported feature
|
|
laps(4), -- not supported feature
|
|
ppp(5) -- not supported feature
|
|
}
|
|
|
|
OrderLevelEnum ::= INTEGER {
|
|
highOrder(1),
|
|
lowOrder(2)
|
|
}
|
|
|
|
STM1SlotNumber ::= INTEGER(2)
|
|
TUGIndex ::= INTEGER(1..3)
|
|
TUGIndexOrZero ::= INTEGER(0..3)
|
|
|
|
-- STM-1 Card: STM-1 Card Table
|
|
|
|
stm1CardTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Stm1CardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing stm1 card specific information."
|
|
::= { pegasusSdhMibModule 1 }
|
|
|
|
stm1CardEntry OBJECT-TYPE
|
|
SYNTAX Stm1CardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row and index definition for stm1 card table."
|
|
INDEX { stm1CardSlotNumber }
|
|
::= { stm1CardTable 1 }
|
|
|
|
Stm1CardEntry ::= SEQUENCE {
|
|
stm1CardSlotNumber STM1SlotNumber,
|
|
-- identification
|
|
stm1CardName DisplayString,
|
|
stm1CardHardwareVersion DisplayString,
|
|
stm1CardFirmwareVersion DisplayString,
|
|
stm1CardManufacturer DisplayString,
|
|
stm1CardSerialNumber DisplayString,
|
|
-- configuration
|
|
stm1CardMultiplexingMode MultiplexingModeEnum,
|
|
stm1CardJ0TraceMonitoring OperStateEnum,
|
|
stm1CardJ1TraceMonitoring OperStateEnum,
|
|
stm1CardJ2TraceMonitoring OperStateEnum,
|
|
stm1CardJ0PathTraceSize TraceSizeEnum,
|
|
stm1CardJ0PathTraceSend DisplayString, -- same as sonetMediumCircuitIdentifier
|
|
stm1CardJ0PathTraceExpected DisplayString,
|
|
stm1CardJ0PathTraceReceive DisplayString,
|
|
stm1CardLaserOperationMode LaserOperationModeEnum,
|
|
stm1CardLaserState LaserStateEnum,
|
|
-- supervision
|
|
stm1CardOperState OperStateEnum,
|
|
stm1CardAvailabilityState AvailabilityStatusElem,
|
|
stm1CardMgmtCommState CommStateEnum,
|
|
-- maintenance
|
|
stm1CardPRBSGeneratorSink SdhInterfaceEnum,
|
|
stm1CardPRBSAnalyzerSource SdhInterfaceEnum,
|
|
stm1CardPRBSPattern PRBSPatternEnum,
|
|
-- additional card alarm status
|
|
stm1CardAlarmStatus Integer32
|
|
}
|
|
|
|
stm1CardSlotNumber OBJECT-TYPE
|
|
SYNTAX STM1SlotNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot number for stm1 card."
|
|
::= { stm1CardEntry 1 }
|
|
|
|
stm1CardName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the PEGASUS device."
|
|
::= { stm1CardEntry 2 }
|
|
|
|
stm1CardHardwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hardware version of the STM-1 card. This is also called CHM-number
|
|
(it always starts with the letters 'CHM'). The number '404' after
|
|
'CHM' identifies the card as a STM-1 card."
|
|
::= { stm1CardEntry 3 }
|
|
|
|
stm1CardFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Version number and build date of the firmware running on the line
|
|
card. The format is 'major.minor YYYYMMDD hh:mm'."
|
|
::= { stm1CardEntry 4 }
|
|
|
|
stm1CardManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manufacturer of the STM-1 card."
|
|
::= { stm1CardEntry 5 }
|
|
|
|
stm1CardSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial number of the line card. Also called HM-number, as it always
|
|
starts with 'HM'. Example: HMVSS014810294."
|
|
::= { stm1CardEntry 6 }
|
|
|
|
stm1CardMultiplexingMode OBJECT-TYPE
|
|
SYNTAX MultiplexingModeEnum
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects the SDH multiplexing mode. Either it is STM1-AU3-VC3 or
|
|
STM1-AU4-VC4."
|
|
::= { stm1CardEntry 7 }
|
|
|
|
stm1CardJ0TraceMonitoring OBJECT-TYPE
|
|
SYNTAX OperStateEnum
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If trace monitoring is disable no alarm is propagated to PEM and
|
|
also no RDI/AIS is inserted."
|
|
::= { stm1CardEntry 8 }
|
|
|
|
stm1CardJ1TraceMonitoring OBJECT-TYPE
|
|
SYNTAX OperStateEnum
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If trace monitoring is disable no alarm is propagated to PEM and
|
|
also no RDI/AIS is inserted."
|
|
::= { stm1CardEntry 9 }
|
|
|
|
stm1CardJ2TraceMonitoring OBJECT-TYPE
|
|
SYNTAX OperStateEnum
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If trace monitoring is disable no alarm is propagated to PEM and
|
|
also no RDI/AIS is inserted."
|
|
::= { stm1CardEntry 10 }
|
|
|
|
stm1CardJ0PathTraceSize OBJECT-TYPE
|
|
SYNTAX TraceSizeEnum
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Size of the Regenerator Section Trace Message."
|
|
::= { stm1CardEntry 11 }
|
|
|
|
stm1CardJ0PathTraceSend OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configurable Regenerator Section (RS) Trace Message."
|
|
::= { stm1CardEntry 12 }
|
|
|
|
stm1CardJ0PathTraceExpected OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Regenerator Section (RS) Trace Message that should be received."
|
|
::= { stm1CardEntry 13 }
|
|
|
|
stm1CardJ0PathTraceReceive OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Regenerator Section (RS) Trace Message that is be received."
|
|
::= { stm1CardEntry 14 }
|
|
|
|
stm1CardLaserOperationMode OBJECT-TYPE
|
|
SYNTAX LaserOperationModeEnum
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration of the 'Automatic Laser Shutdown' feature."
|
|
::= { stm1CardEntry 15 }
|
|
|
|
stm1CardLaserState OBJECT-TYPE
|
|
SYNTAX LaserStateEnum
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual state of the laser."
|
|
::= { stm1CardEntry 16 }
|
|
|
|
stm1CardOperState OBJECT-TYPE
|
|
SYNTAX OperStateEnum
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operational state is a status property indicating whether or
|
|
not a device is physically installed and working.
|
|
enabled The device is partially or fully operable and available
|
|
for use.
|
|
disabled The device is totally inoperable and unavailable to provide
|
|
service."
|
|
::= { stm1CardEntry 17 }
|
|
|
|
stm1CardAvailabilityState OBJECT-TYPE
|
|
SYNTAX AvailabilityStatusElem
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The availability status gives more detailed information about
|
|
failures within a device. An empty status set means that no error
|
|
exists. Possible status are:
|
|
in test The device is under test.
|
|
failed The device has an internal fault that prevents it from
|
|
operating.
|
|
power off The device requires power to be applied and is not
|
|
powered on.
|
|
off line The device requires a routine operation to be performed
|
|
to place it online and make it available for use.
|
|
off duty The device has been made inactive by an internal control
|
|
process in accordance with a predetermined time
|
|
schedule.
|
|
dependency The device can not operate because some other resource
|
|
on which it depends is unavailable.
|
|
degraded The device is partially defective but still operable.
|
|
not installed The device is not present, or incomplete.
|
|
log full The log is full."
|
|
::= { stm1CardEntry 18 }
|
|
|
|
stm1CardMgmtCommState OBJECT-TYPE
|
|
SYNTAX CommStateEnum
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Management Comm State indicates the state of the management
|
|
connection between the PEM Server and the STM-1 card.
|
|
disconnected No connection has been established.
|
|
init A connection has freshly been established on
|
|
the underlying protocol, but no management
|
|
information has been transmitted so far.
|
|
identification The connected device is being identified.
|
|
check hardware The connected hardware is compared to the one
|
|
stored in the configuration.
|
|
hardware adaptation If the configured and the existing device do
|
|
not match, an adoption is made. The behaviour
|
|
in this case can be configured with the 'HW
|
|
Adaptation Policy' option.
|
|
check program version The program version of the connected hardware
|
|
is compared to the one stored in the
|
|
configuration.
|
|
check config version The configuration version of the connected
|
|
hardware is compared to the one stored in the
|
|
configuration.
|
|
download config If a configuration version mismatch has been
|
|
detected and the 'Config Priority' of 'PEGASUS
|
|
system' is set to 'Device', the configuration
|
|
is downloaded from the device to the PEM
|
|
Server.
|
|
upload config If a configuration version mismatch has been
|
|
detected and the 'Config Priority' of 'PEGASUS
|
|
system' is set to 'Server', the configuration
|
|
is uploaded from the PEM Server to the device.
|
|
status synch The values of the status properties are being
|
|
synchronised.
|
|
resetting The device is resetting.
|
|
inactive The device is connected, but it is inactive,
|
|
that is not operational. This may be due to a
|
|
hardware mismatch.
|
|
active The management connection between the device
|
|
and the PEM Server is fully established and
|
|
the device is active."
|
|
::= { stm1CardEntry 19 }
|
|
|
|
stm1CardPRBSGeneratorSink OBJECT-TYPE
|
|
SYNTAX SdhInterfaceEnum
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines, whether the PRBS Generator should be used on the
|
|
optical or on the E1 links."
|
|
::= { stm1CardEntry 20 }
|
|
|
|
stm1CardPRBSAnalyzerSource OBJECT-TYPE
|
|
SYNTAX SdhInterfaceEnum
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines, whether the PRBS Analyzer should be used on the
|
|
optical or on the E1 links."
|
|
::= { stm1CardEntry 21 }
|
|
|
|
stm1CardPRBSPattern OBJECT-TYPE
|
|
SYNTAX PRBSPatternEnum
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines the PRBS Pattern to be used."
|
|
::= { stm1CardEntry 22 }
|
|
|
|
stm1CardAlarmStatus OBJECT-TYPE
|
|
SYNTAX Integer32 (1..511)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the status of STM-1 card, regenerator
|
|
section and multiplex section. It's a bitmap represented as a sum.
|
|
Therefore multiple alarms can be displayed simultaneously. The value
|
|
noAlarm is only set if there isn't any alarm active.
|
|
The various bit positions are:
|
|
1 No alarm present
|
|
-- STM-1 card --
|
|
2 Initialization failure
|
|
4 Firmware Version Mismatch
|
|
8 Maintenance
|
|
-- regenerator section RS --
|
|
16 Loss of Signal (LOS)
|
|
32 Loss of Frame (LOF)
|
|
64 Trace ID Mismatch (RS-TIM)
|
|
-- multiplex section MS --
|
|
128 Alarm Indication Signal (MS-AIS)
|
|
256 Remote Defect Indication (MS-RDI, former FERF)"
|
|
::= { stm1CardEntry 23 }
|
|
|
|
-- STM-1 Card: STM-1 Card Clock Table
|
|
|
|
stm1CardClockTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Stm1CardClockEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing stm1 card specific clock information."
|
|
::= { pegasusSdhMibModule 2 }
|
|
|
|
stm1CardClockEntry OBJECT-TYPE
|
|
SYNTAX Stm1CardClockEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row and index definition for stm1 card clock table."
|
|
INDEX { stm1CardSlotNumber }
|
|
::= { stm1CardClockTable 1 }
|
|
|
|
Stm1CardClockEntry ::= SEQUENCE {
|
|
-- clock settings
|
|
stm1CardActiveClockSource ClockSourceEnum,
|
|
stm1CardClockSyncState ClockSyncStateEnum,
|
|
stm1CardTxLineClockQuality ClockQualityEnum,
|
|
stm1CardRxClockMode ClockModeEnum,
|
|
stm1CardRxClockPriority ClockPriorityEnum,
|
|
stm1CardRxClockQuality ClockQualityEnum,
|
|
stm1CardRxClockState ClockStateEnum,
|
|
stm1CardReferenceClockMode ClockModeEnum,
|
|
stm1CardReferenceClockPriority ClockPriorityEnum,
|
|
stm1CardReferenceClockQuality ClockQualityEnum,
|
|
stm1CardReferenceClockState ClockStateEnum
|
|
}
|
|
|
|
stm1CardActiveClockSource OBJECT-TYPE
|
|
SYNTAX ClockSourceEnum
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays which clock sourceis active and used as sync source."
|
|
::= { stm1CardClockEntry 1 }
|
|
|
|
stm1CardClockSyncState OBJECT-TYPE
|
|
SYNTAX ClockSyncStateEnum
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sync status is OK if RX or Reference clock is valid and used as
|
|
active sync source."
|
|
::= { stm1CardClockEntry 2 }
|
|
|
|
stm1CardTxLineClockQuality OBJECT-TYPE
|
|
SYNTAX ClockQualityEnum
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the clock quality of the outgoing SDH signal. The default
|
|
sets the outgoing quality to the incoming quality. Sometime it may
|
|
be useful to set a fix outgoing quality."
|
|
::= { stm1CardClockEntry 3 }
|
|
|
|
stm1CardRxClockMode OBJECT-TYPE
|
|
SYNTAX ClockModeEnum
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If enabled the RX line clock can be used as sync source."
|
|
::= { stm1CardClockEntry 4 }
|
|
|
|
stm1CardRxClockPriority OBJECT-TYPE
|
|
SYNTAX ClockPriorityEnum
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value has always the opposite value of Reference Clock
|
|
Priority."
|
|
::= { stm1CardClockEntry 5 }
|
|
|
|
stm1CardRxClockQuality OBJECT-TYPE
|
|
SYNTAX ClockQualityEnum
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the clock quality of the incoming SDH signal."
|
|
::= { stm1CardClockEntry 6 }
|
|
|
|
stm1CardRxClockState OBJECT-TYPE
|
|
SYNTAX ClockStateEnum
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock status is valid if a good clock can be found on input
|
|
(clock checker)."
|
|
::= { stm1CardClockEntry 7 }
|
|
|
|
stm1CardReferenceClockMode OBJECT-TYPE
|
|
SYNTAX ClockModeEnum
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If enabled the Reference clock (V5 card input) can be used as sync
|
|
source."
|
|
::= { stm1CardClockEntry 8 }
|
|
|
|
stm1CardReferenceClockPriority OBJECT-TYPE
|
|
SYNTAX ClockPriorityEnum
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value has always the opposite value of Rx Clock Priority."
|
|
::= { stm1CardClockEntry 9 }
|
|
|
|
stm1CardReferenceClockQuality OBJECT-TYPE
|
|
SYNTAX ClockQualityEnum
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the quality of the reference clock input. This value will
|
|
be transmitted in SDH-TX if reference clock is used as active sync
|
|
source."
|
|
::= { stm1CardClockEntry 10 }
|
|
|
|
stm1CardReferenceClockState OBJECT-TYPE
|
|
SYNTAX ClockStateEnum
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock status is valid if a good clock can be found on input
|
|
(clock checker)."
|
|
::= { stm1CardClockEntry 11 }
|
|
|
|
|
|
-- STM-1 Card: Ethernet Interface Table
|
|
|
|
ethernetIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EthernetIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains additional information concerning the ethernet
|
|
interfaces of a STM-1 card. It represents an extension of the
|
|
if(X)Table (see IF-MIB)."
|
|
::= { pegasusSdhMibModule 3 }
|
|
|
|
ethernetIfEntry OBJECT-TYPE
|
|
SYNTAX EthernetIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row and index definition for the ethernetIfTable."
|
|
INDEX { ifIndex }
|
|
::= { ethernetIfTable 1 }
|
|
|
|
EthernetIfEntry ::= SEQUENCE {
|
|
etherIfConcatenationOption ConcatenationTypeEnum,
|
|
etherIfEncapsulation EthernetIfEncapsulationEnum,
|
|
etherIfOrderLevel OrderLevelEnum,
|
|
etherIfAlarmStatus Integer32
|
|
}
|
|
|
|
etherIfConcatenationOption OBJECT-TYPE
|
|
SYNTAX ConcatenationTypeEnum
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration of the Link Capacity Adjustment Scheme."
|
|
::= { ethernetIfEntry 1 }
|
|
|
|
etherIfEncapsulation OBJECT-TYPE
|
|
SYNTAX EthernetIfEncapsulationEnum
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute shows the used Ethernet encapsulation protocol."
|
|
::= { ethernetIfEntry 2 }
|
|
|
|
etherIfOrderLevel OBJECT-TYPE
|
|
SYNTAX OrderLevelEnum
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Only relevant, if SDH Multiplexing Mode (see STM-1 card propertied)
|
|
is set to VC3."
|
|
::= { ethernetIfEntry 3 }
|
|
|
|
etherIfAlarmStatus OBJECT-TYPE
|
|
SYNTAX Integer32 (1..511)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the status of an Ethernet Interface. It's
|
|
a bitmap represented as a sum. Therefore multiple defects can be
|
|
displayed simultaneously. The value noAlarm is only set if there
|
|
isn't any alarm.
|
|
The various bit positions are (LO = LowOrder, HO = HighOrder):
|
|
1 No alarm
|
|
2 LO LCAS group identifier mismatch (Rx)
|
|
4 HO LCAS group identifier mismatch (Rx)
|
|
8 LO VCG exceeds max. differential delay (Rx)
|
|
16 HO VCG exceeds max. differential delay (Rx)
|
|
32 LO VCG exceeds max. differential delay, calculated over all
|
|
containers (Rx)
|
|
64 HO VCG exceeds max. differential delay, calculated over all
|
|
containers (Rx)
|
|
128 Transmit FIFO overflow (Tx)
|
|
256 Rx head-of-line blocking FIFO overflow"
|
|
::= { ethernetIfEntry 4 }
|
|
|
|
-- STM-1 Card: Virtual Container (VC) Configuration Table
|
|
|
|
vcTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains additional information for VC concerning the
|
|
multiplexing configuration. It's an extension of the ifTable
|
|
(IF-MIB) and the tables of the SONET/SDH-MIB.
|
|
"
|
|
::= { pegasusSdhMibModule 4 }
|
|
|
|
vcEntry OBJECT-TYPE
|
|
SYNTAX VcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row and index definition for the vcConfigTable."
|
|
INDEX { ifIndex }
|
|
::= { vcTable 1 }
|
|
|
|
VcEntry ::= SEQUENCE {
|
|
vcType VirtualContainerTypeEnum,
|
|
vcRelatedTUG TUGIndexOrZero,
|
|
vcRelatedVC InterfaceIndexOrZero,
|
|
vcAssignedIfIndex InterfaceIndexOrZero,
|
|
vcPathTraceSend DisplayString, -- same as dsx1CircuitIdentifier
|
|
vcPathTraceExpected DisplayString,
|
|
vcPathTraceReceive DisplayString,
|
|
vcSignalLabelSend SignalLabel,
|
|
vcSignalLabelExpected SignalLabel,
|
|
vcSignalLabelReceive SignalLabel,
|
|
vcAlarmStatus Integer32
|
|
}
|
|
|
|
vcType OBJECT-TYPE
|
|
SYNTAX VirtualContainerTypeEnum
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of Virtual Container (VC). In Pegasus VC-4, VC-3 or VC-12."
|
|
::= { vcEntry 1 }
|
|
|
|
vcRelatedTUG OBJECT-TYPE
|
|
SYNTAX TUGIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents the index of the Tributary Unit Group within the
|
|
tugConfigTable to which this VC is assigned to. The value depends
|
|
also on the multiplexing mode. If the value is 0, there doesn't
|
|
exist the relation VC-x to TUG-3. Possible values:
|
|
1) multiplexing mode = AU-4:
|
|
VC-4: vcRelatedTUG = 0
|
|
VC-3/12: vcRelatedTUG = 1..3
|
|
2) multiplexing mode = AU-3:
|
|
vcRelatedTUG = 0 (no dependency on VC type)"
|
|
::= { vcEntry 2 }
|
|
|
|
vcRelatedVC OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents the index of the Virtual Container within the
|
|
ifTable to which this VC is assigned to. The value depends
|
|
also on the multiplexing mode. If the value is 0, there doesn't
|
|
exist the relation VC-x to VC-x. Possible values:
|
|
1) multiplexing mode = AU-4:
|
|
vcRelatedVC = 0 (no dependency on VC type)
|
|
2) multiplexing mode = AU-3:
|
|
VC-3: vcRelatedVC = 0
|
|
VC-12: vcRelatedVC = 2031..2033 (example for slot 2)"
|
|
::= { vcEntry 3 }
|
|
|
|
vcAssignedIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents the index of the interface within the ifTable (IF-MIB)
|
|
that transmits to this VC."
|
|
::= { vcEntry 4 }
|
|
|
|
vcPathTraceSend OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of the outgoing J1 Byte VC Path Trace byte message."
|
|
::= { vcEntry 5 }
|
|
|
|
vcPathTraceExpected OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of the expected J1 Byte VC Path Trace byte message."
|
|
::= { vcEntry 6 }
|
|
|
|
vcPathTraceReceive OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of the incoming J1 Byte VC Path Trace byte message."
|
|
::= { vcEntry 7 }
|
|
|
|
vcSignalLabelSend OBJECT-TYPE
|
|
SYNTAX SignalLabel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The outgoing C2 VC Signal Label (0x02 = TUG structure)."
|
|
::= { vcEntry 8 }
|
|
|
|
vcSignalLabelExpected OBJECT-TYPE
|
|
SYNTAX SignalLabel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The expected C2 VC Signal Label (0x02 = TUG structure)."
|
|
::= { vcEntry 9 }
|
|
|
|
vcSignalLabelReceive OBJECT-TYPE
|
|
SYNTAX SignalLabel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The incoming C2 VC Signal Label (0x02 = TUG structure)."
|
|
::= { vcEntry 10 }
|
|
|
|
vcAlarmStatus OBJECT-TYPE
|
|
SYNTAX Integer32 (1..524287)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the status of the VC. It's a bitmap
|
|
represented as a sum. Therefore multiple defects can be displayed
|
|
simultaneously. The value noDefect should only be set if there is
|
|
no other defect. Some alarms can't occur actually.
|
|
The various bit positions are:
|
|
1 vcNoDefect
|
|
2 vcAlarmAIS
|
|
4 vcAlarmLOP
|
|
8 vcAlarmRDI
|
|
16 vcAlarmUnequipped
|
|
32 vcAlarmPLM
|
|
64 vcAlarmTIM
|
|
128 vcAlarmLOM
|
|
256 vcAlarmRFI
|
|
512 vcgTxAddTimeout -- not used (deprecated)
|
|
1024 vcgTxAdd -- not used (deprecated)
|
|
2048 vcgTxRemove -- not used (deprecated)
|
|
4096 vcgTxDnu -- not used (deprecated)
|
|
8192 vcgDnuOk -- not used (deprecated)
|
|
16384 vcgRxAdd -- not used (deprecated)
|
|
32768 vcgRxRemove -- not used (deprecated)
|
|
65536 vcgRxFail -- not used (deprecated)
|
|
131072 vcgLcasCrcError
|
|
262144 vcgNonLcasSeqError"
|
|
::= { vcEntry 11 }
|
|
|
|
-- STM-1 Card: Tributary Unit Group (TUG) Configuration Table
|
|
|
|
tugConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TugConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information concerning Tributary Unit Groups.
|
|
If AU-3 structure is used, this table is empty."
|
|
::= { pegasusSdhMibModule 5 }
|
|
|
|
tugConfigEntry OBJECT-TYPE
|
|
SYNTAX TugConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row and index definition for the tugConfigTable."
|
|
INDEX { tugIndex }
|
|
::= { tugConfigTable 1 }
|
|
|
|
TugConfigEntry ::= SEQUENCE {
|
|
tugIndex TUGIndex,
|
|
tugRelatedVC4 InterfaceIndex,
|
|
tugOrderLevel OrderLevelEnum
|
|
}
|
|
|
|
tugIndex OBJECT-TYPE
|
|
SYNTAX TUGIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of the TUG. Range 1..3"
|
|
::= { tugConfigEntry 1 }
|
|
|
|
tugRelatedVC4 OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { tugConfigEntry 2 }
|
|
|
|
tugOrderLevel OBJECT-TYPE
|
|
SYNTAX OrderLevelEnum
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Individual Order Level of this TUG. If high order is used, the TUG
|
|
has exactly one VC-3 and no VC-12s. If low order is used, the TUG
|
|
has exactly 21 VC-12 and no VC-3."
|
|
::= { tugConfigEntry 3 }
|
|
|
|
|
|
-- STM-1 Support: Additional information
|
|
|
|
sdhMibRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version number assigned by the version control system. You can query
|
|
this from the agent, to find out with which version of the MIB was built
|
|
into the agent. The value is also present in copies of the MIB to feed
|
|
into SNMP managers. Comparing the version numbers from both sources can
|
|
help to detect mismatches. The revision string for this version is:
|
|
$Workfile: PEGASUS-SDH-MIB.txt $ $Revision: 14 $ $Date: 3/18/04 6:40p $"
|
|
DEFVAL { "$Workfile: PEGASUS-SDH-MIB.txt $ $Revision: 14 $ $Date: 3/18/04 6:40p $" }
|
|
::= { pegasusSdhMibModule 6 }
|
|
|
|
END
|