NETGEAR-POWER-ETHERNET-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- Copyright Netgear Inc (2003-2015) All rights reserved.
|
|
|
|
-- This SNMP Management Information Specification
|
|
-- embodies Netgear Inc's confidential and proprietary
|
|
-- intellectual property. Netgear Inc retains all title
|
|
-- and ownership in the Specification including any revisions.
|
|
|
|
-- This Specification is supplied "AS IS", Netgear Inc
|
|
-- makes no warranty, either expressed or implied,
|
|
-- as to the use, operation, condition, or performance of the
|
|
-- Specification.
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Gauge32 FROM SNMPv2-SMI
|
|
TruthValue FROM SNMPv2-TC
|
|
lb6m FROM QUANTA-LB6M-REF-MIB
|
|
DisplayString FROM RFC1213-MIB
|
|
pethPsePortEntry, pethMainPseEntry FROM POWER-ETHERNET-MIB;
|
|
|
|
|
|
fastPathpowerEthernetMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201503130000Z" -- 13 Mar 2015 12:00:00 GMT
|
|
ORGANIZATION "Netgear Inc"
|
|
CONTACT-INFO ""
|
|
|
|
DESCRIPTION
|
|
"This MIB Augments the POWER-ETHERNET-MIB created by the IETF Ethernet
|
|
Interfaces and Hub MIB Working Group for managing Power Source
|
|
Equipment (PSE). The objects in this MIB are intended to provide
|
|
additional objects for reporting information available to the hardware
|
|
on this platform which are not represented in the draft MIB."
|
|
|
|
-- Revision history.
|
|
REVISION
|
|
"201503130000Z" -- 13 Mar 2015 12:00:00 GMT
|
|
DESCRIPTION
|
|
"agentPethPsePowerManagementMode object description is updated."
|
|
REVISION
|
|
"201404160000Z" -- 16 Apr 2014 12:00:00 GMT
|
|
DESCRIPTION
|
|
"Upoe support added in new object agentPethHighPowerMode."
|
|
REVISION
|
|
"201101260000Z" -- 26 Jan 2011 12:00:00 GMT
|
|
DESCRIPTION
|
|
"Postal address updated."
|
|
REVISION
|
|
"200708191200Z" -- 17 Aug 2007 12:00:00 GMT
|
|
DESCRIPTION
|
|
"PoE support for BCM59101 added."
|
|
REVISION
|
|
"200705230000Z" -- 23 May 2007 12:00:00 GMT
|
|
DESCRIPTION
|
|
"Netgear branding related changes."
|
|
REVISION
|
|
"200311101200Z" -- 10 Nov 2003 12:00:00 GMT
|
|
DESCRIPTION
|
|
"Initial revision."
|
|
::= { lb6m 15 }
|
|
|
|
agentPethObjects OBJECT IDENTIFIER ::= { fastPathpowerEthernetMIB 1 }
|
|
|
|
agentPethPsePortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgentPethPsePortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of per-port information and configuration objects relating
|
|
to the power status of each port."
|
|
::= { agentPethObjects 1 }
|
|
|
|
agentPethPsePortEntry OBJECT-TYPE
|
|
SYNTAX AgentPethPsePortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing additional power information
|
|
and control parameters for the specified port."
|
|
AUGMENTS { pethPsePortEntry }
|
|
::= { agentPethPsePortTable 1 }
|
|
|
|
AgentPethPsePortEntry ::= SEQUENCE {
|
|
agentPethPowerLimit
|
|
Gauge32,
|
|
agentPethOutputPower
|
|
Gauge32,
|
|
agentPethOutputCurrent
|
|
Gauge32,
|
|
agentPethOutputVolts
|
|
Gauge32,
|
|
agentPethTemperature
|
|
Gauge32,
|
|
agentPethPowerLimitType
|
|
INTEGER,
|
|
agentPethHighPowerEnable
|
|
TruthValue,
|
|
agentPethPowerDetectionType
|
|
INTEGER,
|
|
agentPethFaultStatus
|
|
INTEGER,
|
|
agentPethPortReset
|
|
INTEGER,
|
|
agentPethPowerLimitMin
|
|
Gauge32,
|
|
agentPethPowerLimitMax
|
|
Gauge32
|
|
,
|
|
agentPethHighPowerMode
|
|
INTEGER
|
|
}
|
|
|
|
agentPethPowerLimit OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "Milliwatts"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The configured maximum power this port can provide to an
|
|
attached device measured in Milliwatts."
|
|
::= { agentPethPsePortEntry 1 }
|
|
|
|
agentPethOutputPower OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "Milliwatts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power this port is supplying to an attached device measured
|
|
in Milliwatts."
|
|
::= { agentPethPsePortEntry 2 }
|
|
|
|
agentPethOutputCurrent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "Milliamps"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current this port is supplying to an attached device measured
|
|
in Milliamps."
|
|
::= { agentPethPsePortEntry 3 }
|
|
|
|
agentPethOutputVolts OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The voltage this port is supplying to an attached device measured
|
|
in Volts."
|
|
::= { agentPethPsePortEntry 4 }
|
|
|
|
agentPethTemperature OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "DEGREES"
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The temperature measured at this port of the PoE Controller. It is
|
|
measured in degree celcius."
|
|
::= { agentPethPsePortEntry 5 }
|
|
|
|
agentPethPowerLimitType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dot3af(1),
|
|
user(2),
|
|
none(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes or controls the maximum power that a port can deliver.
|
|
A value of dot3af(1) means that the port power limit is as per
|
|
the dot3af class of the PD attached.
|
|
A value of user(2) means that the port power limit is equal to the value
|
|
specified by agentPethPowerLimit"
|
|
REFERENCE
|
|
"Broadcom 5910X programmers guide, IEEE Std 802.3af Section 30.9.1.1.6"
|
|
::= { agentPethPsePortEntry 6 }
|
|
|
|
agentPethHighPowerEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"true (1) The PSE port can deliver power up to 32Watts.
|
|
false(2) The PSE port can deliver power up to 18Watts"
|
|
REFERENCE
|
|
"Broadcom 5910X programmers guide"
|
|
|
|
::= { agentPethPsePortEntry 7 }
|
|
|
|
agentPethPowerDetectionType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
pre-ieee(1),
|
|
ieee(2),
|
|
auto(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes PD detection mechanism performed by the PSE port.
|
|
A value of none(0) means no detection is done.
|
|
A value of pre-ieee(1) means only legacy capacitive detection scheme is
|
|
used.
|
|
A value of ieee(2) means that IEEE 802.3af 4point detection scheme is used.
|
|
A value of auto(3) means that IEEE 802.3af 4point detection scheme is used
|
|
and when that fails to detect a connected PD, legacity capacitive detection
|
|
is used.
|
|
The value 'none' can not be forcibly set by the administrator."
|
|
REFERENCE
|
|
"Broadcom 5910X programmers guide, IEEE Std 802.3af Section 30.9.1.1.6"
|
|
::= { agentPethPsePortEntry 8 }
|
|
|
|
agentPethFaultStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
mpsAbsent(1),
|
|
short(2),
|
|
overload(3),
|
|
powerDenied(4),
|
|
thermalShutdown(5),
|
|
startupFailure(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the error description when the pse port is in fault status.
|
|
A value of none(0) specifies that the pse port is not in any error state.
|
|
A value of mpsAbsent(1) specifies that the pse port has detected and absence
|
|
of main power supply.
|
|
A value of short(2) specifies that the pse port has detected a short circuit
|
|
condition.
|
|
A value of overload(3) specifies that the pd connected to the pse port had tried
|
|
to draw more power than permissible by the hardware.
|
|
A value of powerDenied(4) specifies that the pse port has been denied power
|
|
because of shortage of power or due to administrative action.
|
|
A value of thermalShutdown(5) specifies that the thermal threshold has exceeded
|
|
for the pse port.
|
|
A value of startupFailure(6) as fault status indicates that the port does not have
|
|
sufficient voltage."
|
|
REFERENCE
|
|
"Broadcom 5910X programmers guide, IEEE Std 802.3af"
|
|
|
|
::= { agentPethPsePortEntry 9 }
|
|
|
|
agentPethPortReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
reset(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A value of reset(1) is used to move the pse port dot3af state to idle. A
|
|
read on this object will always return the value none(0). The value none(0)
|
|
can not be forcibly set by the administrtor."
|
|
REFERENCE
|
|
"Broadcom 5910X programmers guide, IEEE Std 802.3af"
|
|
::= { agentPethPsePortEntry 10 }
|
|
|
|
agentPethPowerLimitMin OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "Milliwatts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum power this port can be configured to provide, measured in Milliwatts."
|
|
::= { agentPethPsePortEntry 11 }
|
|
|
|
agentPethPowerLimitMax OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "Milliwatts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum power this port can be configured to provide, measured in Milliwatts."
|
|
::= { agentPethPsePortEntry 12 }
|
|
|
|
agentPethHighPowerMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
legacy(1),
|
|
pre-dot3at(2),
|
|
dot3at(3),
|
|
upoe(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The mode configured for a PSE port to deliver high power. 'disable' means that
|
|
a port is powered in the IEEE 802.3af mode. 'legacy' means that a port is
|
|
powered using high-inrush current. 'pre-dot3at' means that a port is powered
|
|
in the IEEE 802.3af mode initially, switched to the high-power IEEE 802.3at mode
|
|
before 75msec. 'dot3at' means that a port is powered in the IEEE 802.3at mode.
|
|
'upoe' means that a port is powered in IEEE 802.3at mode using spare pair and
|
|
data pair simultaneously to deliver up to 60W power."
|
|
::= { agentPethPsePortEntry 13 }
|
|
|
|
-- Main objects
|
|
agentPethMainPseObjects OBJECT IDENTIFIER ::= { agentPethObjects 2 }
|
|
|
|
agentPethMainPseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgentPethMainPseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of objects that display and control attributes
|
|
of the main power source in a PSE device. Ethernet
|
|
switches are one example of boxes that would support
|
|
these objects.
|
|
Values of all read-write objects in this table are
|
|
persistent at restart/reboot."
|
|
::= { agentPethMainPseObjects 1 }
|
|
|
|
agentPethMainPseEntry OBJECT-TYPE
|
|
SYNTAX AgentPethMainPseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set of objects that display and control the Main
|
|
power of a PSE. "
|
|
AUGMENTS { pethMainPseEntry }
|
|
::= { agentPethMainPseTable 1 }
|
|
|
|
AgentPethMainPseEntry ::= SEQUENCE {
|
|
agentPethMainPseLegacy
|
|
TruthValue
|
|
}
|
|
|
|
agentPethMainPseLegacy OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable Legacy device detection. The
|
|
value true(1) means legacy devices are detected; the
|
|
value false(2) means legacy devices are not detected."
|
|
::= { agentPethMainPseEntry 1 }
|
|
|
|
agentPethPseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgentPethPseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of per-unit information and configuration objects relating
|
|
to the power configurtion for the entire pse unit."
|
|
::= { agentPethObjects 3 }
|
|
|
|
agentPethPseEntry OBJECT-TYPE
|
|
SYNTAX AgentPethPseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing additional power information
|
|
and control parameters for the specified pse unit."
|
|
AUGMENTS { pethMainPseEntry }
|
|
::= { agentPethPseTable 1 }
|
|
|
|
AgentPethPseEntry ::= SEQUENCE {
|
|
agentPethPsePowerManagementMode
|
|
|
|
INTEGER
|
|
,
|
|
agentPethPseCardModel
|
|
DisplayString,
|
|
agentPethPseCardHost
|
|
DisplayString,
|
|
agentPethPseCardStatus
|
|
INTEGER
|
|
}
|
|
|
|
agentPethPsePowerManagementMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
dynamic(1),
|
|
static(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes or controls the power management algorithm used by the pse
|
|
to deliver power to the requesting PDsthat a pds.
|
|
A value of dynamic(1) means that power consumption of each port
|
|
is measured and calculated in real-time.
|
|
A value of static(2) means that power allocated for each port depends
|
|
on the type of power threshold configured on the port."
|
|
REFERENCE
|
|
"Broadcom 5910X programmers guide"
|
|
|
|
::= { agentPethPseEntry 1 }
|
|
|
|
agentPethPseCardModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the PoE daughther card model at PSE side."
|
|
|
|
::= { agentPethPseEntry 3 }
|
|
|
|
agentPethPseCardHost OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the board which hosts the PoE daughther card at PSE side."
|
|
|
|
::= { agentPethPseEntry 4 }
|
|
|
|
agentPethPseCardStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
absent-or-failed(0),
|
|
running(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays running status of the PoE daughther card at PSE side. The value
|
|
absent-or-failed(0) means that the card is either not present or some error has occurred.
|
|
The value running(1) means that card is present and working fine."
|
|
|
|
|
|
::= { agentPethPseEntry 5 }
|
|
|
|
END
|