mibs/MIBS/quanta/fastpath_power_ethernet.my
2023-12-05 12:25:34 +01:00

428 lines
15 KiB
Plaintext

NETGEAR-POWER-ETHERNET-MIB DEFINITIONS ::= BEGIN
-- Copyright Netgear Inc (2003-2015) All rights reserved.
-- This SNMP Management Information Specification
-- embodies Netgear Inc's confidential and proprietary
-- intellectual property. Netgear Inc retains all title
-- and ownership in the Specification including any revisions.
-- This Specification is supplied "AS IS", Netgear Inc
-- makes no warranty, either expressed or implied,
-- as to the use, operation, condition, or performance of the
-- Specification.
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Gauge32 FROM SNMPv2-SMI
TruthValue FROM SNMPv2-TC
lb6m FROM QUANTA-LB6M-REF-MIB
DisplayString FROM RFC1213-MIB
pethPsePortEntry, pethMainPseEntry FROM POWER-ETHERNET-MIB;
fastPathpowerEthernetMIB MODULE-IDENTITY
LAST-UPDATED "201503130000Z" -- 13 Mar 2015 12:00:00 GMT
ORGANIZATION "Netgear Inc"
CONTACT-INFO ""
DESCRIPTION
"This MIB Augments the POWER-ETHERNET-MIB created by the IETF Ethernet
Interfaces and Hub MIB Working Group for managing Power Source
Equipment (PSE). The objects in this MIB are intended to provide
additional objects for reporting information available to the hardware
on this platform which are not represented in the draft MIB."
-- Revision history.
REVISION
"201503130000Z" -- 13 Mar 2015 12:00:00 GMT
DESCRIPTION
"agentPethPsePowerManagementMode object description is updated."
REVISION
"201404160000Z" -- 16 Apr 2014 12:00:00 GMT
DESCRIPTION
"Upoe support added in new object agentPethHighPowerMode."
REVISION
"201101260000Z" -- 26 Jan 2011 12:00:00 GMT
DESCRIPTION
"Postal address updated."
REVISION
"200708191200Z" -- 17 Aug 2007 12:00:00 GMT
DESCRIPTION
"PoE support for BCM59101 added."
REVISION
"200705230000Z" -- 23 May 2007 12:00:00 GMT
DESCRIPTION
"Netgear branding related changes."
REVISION
"200311101200Z" -- 10 Nov 2003 12:00:00 GMT
DESCRIPTION
"Initial revision."
::= { lb6m 15 }
agentPethObjects OBJECT IDENTIFIER ::= { fastPathpowerEthernetMIB 1 }
agentPethPsePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentPethPsePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of per-port information and configuration objects relating
to the power status of each port."
::= { agentPethObjects 1 }
agentPethPsePortEntry OBJECT-TYPE
SYNTAX AgentPethPsePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of objects providing additional power information
and control parameters for the specified port."
AUGMENTS { pethPsePortEntry }
::= { agentPethPsePortTable 1 }
AgentPethPsePortEntry ::= SEQUENCE {
agentPethPowerLimit
Gauge32,
agentPethOutputPower
Gauge32,
agentPethOutputCurrent
Gauge32,
agentPethOutputVolts
Gauge32,
agentPethTemperature
Gauge32,
agentPethPowerLimitType
INTEGER,
agentPethHighPowerEnable
TruthValue,
agentPethPowerDetectionType
INTEGER,
agentPethFaultStatus
INTEGER,
agentPethPortReset
INTEGER,
agentPethPowerLimitMin
Gauge32,
agentPethPowerLimitMax
Gauge32
,
agentPethHighPowerMode
INTEGER
}
agentPethPowerLimit OBJECT-TYPE
SYNTAX Gauge32
UNITS "Milliwatts"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The configured maximum power this port can provide to an
attached device measured in Milliwatts."
::= { agentPethPsePortEntry 1 }
agentPethOutputPower OBJECT-TYPE
SYNTAX Gauge32
UNITS "Milliwatts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The power this port is supplying to an attached device measured
in Milliwatts."
::= { agentPethPsePortEntry 2 }
agentPethOutputCurrent OBJECT-TYPE
SYNTAX Gauge32
UNITS "Milliamps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current this port is supplying to an attached device measured
in Milliamps."
::= { agentPethPsePortEntry 3 }
agentPethOutputVolts OBJECT-TYPE
SYNTAX Gauge32
UNITS "Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage this port is supplying to an attached device measured
in Volts."
::= { agentPethPsePortEntry 4 }
agentPethTemperature OBJECT-TYPE
SYNTAX Gauge32
UNITS "DEGREES"
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The temperature measured at this port of the PoE Controller. It is
measured in degree celcius."
::= { agentPethPsePortEntry 5 }
agentPethPowerLimitType OBJECT-TYPE
SYNTAX INTEGER {
dot3af(1),
user(2),
none(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes or controls the maximum power that a port can deliver.
A value of dot3af(1) means that the port power limit is as per
the dot3af class of the PD attached.
A value of user(2) means that the port power limit is equal to the value
specified by agentPethPowerLimit"
REFERENCE
"Broadcom 5910X programmers guide, IEEE Std 802.3af Section 30.9.1.1.6"
::= { agentPethPsePortEntry 6 }
agentPethHighPowerEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"true (1) The PSE port can deliver power up to 32Watts.
false(2) The PSE port can deliver power up to 18Watts"
REFERENCE
"Broadcom 5910X programmers guide"
::= { agentPethPsePortEntry 7 }
agentPethPowerDetectionType OBJECT-TYPE
SYNTAX INTEGER {
none(0),
pre-ieee(1),
ieee(2),
auto(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes PD detection mechanism performed by the PSE port.
A value of none(0) means no detection is done.
A value of pre-ieee(1) means only legacy capacitive detection scheme is
used.
A value of ieee(2) means that IEEE 802.3af 4point detection scheme is used.
A value of auto(3) means that IEEE 802.3af 4point detection scheme is used
and when that fails to detect a connected PD, legacity capacitive detection
is used.
The value 'none' can not be forcibly set by the administrator."
REFERENCE
"Broadcom 5910X programmers guide, IEEE Std 802.3af Section 30.9.1.1.6"
::= { agentPethPsePortEntry 8 }
agentPethFaultStatus OBJECT-TYPE
SYNTAX INTEGER {
none(0),
mpsAbsent(1),
short(2),
overload(3),
powerDenied(4),
thermalShutdown(5),
startupFailure(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the error description when the pse port is in fault status.
A value of none(0) specifies that the pse port is not in any error state.
A value of mpsAbsent(1) specifies that the pse port has detected and absence
of main power supply.
A value of short(2) specifies that the pse port has detected a short circuit
condition.
A value of overload(3) specifies that the pd connected to the pse port had tried
to draw more power than permissible by the hardware.
A value of powerDenied(4) specifies that the pse port has been denied power
because of shortage of power or due to administrative action.
A value of thermalShutdown(5) specifies that the thermal threshold has exceeded
for the pse port.
A value of startupFailure(6) as fault status indicates that the port does not have
sufficient voltage."
REFERENCE
"Broadcom 5910X programmers guide, IEEE Std 802.3af"
::= { agentPethPsePortEntry 9 }
agentPethPortReset OBJECT-TYPE
SYNTAX INTEGER {
none(0),
reset(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A value of reset(1) is used to move the pse port dot3af state to idle. A
read on this object will always return the value none(0). The value none(0)
can not be forcibly set by the administrtor."
REFERENCE
"Broadcom 5910X programmers guide, IEEE Std 802.3af"
::= { agentPethPsePortEntry 10 }
agentPethPowerLimitMin OBJECT-TYPE
SYNTAX Gauge32
UNITS "Milliwatts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum power this port can be configured to provide, measured in Milliwatts."
::= { agentPethPsePortEntry 11 }
agentPethPowerLimitMax OBJECT-TYPE
SYNTAX Gauge32
UNITS "Milliwatts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum power this port can be configured to provide, measured in Milliwatts."
::= { agentPethPsePortEntry 12 }
agentPethHighPowerMode OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
legacy(1),
pre-dot3at(2),
dot3at(3),
upoe(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mode configured for a PSE port to deliver high power. 'disable' means that
a port is powered in the IEEE 802.3af mode. 'legacy' means that a port is
powered using high-inrush current. 'pre-dot3at' means that a port is powered
in the IEEE 802.3af mode initially, switched to the high-power IEEE 802.3at mode
before 75msec. 'dot3at' means that a port is powered in the IEEE 802.3at mode.
'upoe' means that a port is powered in IEEE 802.3at mode using spare pair and
data pair simultaneously to deliver up to 60W power."
::= { agentPethPsePortEntry 13 }
-- Main objects
agentPethMainPseObjects OBJECT IDENTIFIER ::= { agentPethObjects 2 }
agentPethMainPseTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentPethMainPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of objects that display and control attributes
of the main power source in a PSE device. Ethernet
switches are one example of boxes that would support
these objects.
Values of all read-write objects in this table are
persistent at restart/reboot."
::= { agentPethMainPseObjects 1 }
agentPethMainPseEntry OBJECT-TYPE
SYNTAX AgentPethMainPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of objects that display and control the Main
power of a PSE. "
AUGMENTS { pethMainPseEntry }
::= { agentPethMainPseTable 1 }
AgentPethMainPseEntry ::= SEQUENCE {
agentPethMainPseLegacy
TruthValue
}
agentPethMainPseLegacy OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable Legacy device detection. The
value true(1) means legacy devices are detected; the
value false(2) means legacy devices are not detected."
::= { agentPethMainPseEntry 1 }
agentPethPseTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentPethPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of per-unit information and configuration objects relating
to the power configurtion for the entire pse unit."
::= { agentPethObjects 3 }
agentPethPseEntry OBJECT-TYPE
SYNTAX AgentPethPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of objects providing additional power information
and control parameters for the specified pse unit."
AUGMENTS { pethMainPseEntry }
::= { agentPethPseTable 1 }
AgentPethPseEntry ::= SEQUENCE {
agentPethPsePowerManagementMode
INTEGER
,
agentPethPseCardModel
DisplayString,
agentPethPseCardHost
DisplayString,
agentPethPseCardStatus
INTEGER
}
agentPethPsePowerManagementMode OBJECT-TYPE
SYNTAX INTEGER {
none(0),
dynamic(1),
static(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes or controls the power management algorithm used by the pse
to deliver power to the requesting PDsthat a pds.
A value of dynamic(1) means that power consumption of each port
is measured and calculated in real-time.
A value of static(2) means that power allocated for each port depends
on the type of power threshold configured on the port."
REFERENCE
"Broadcom 5910X programmers guide"
::= { agentPethPseEntry 1 }
agentPethPseCardModel OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the PoE daughther card model at PSE side."
::= { agentPethPseEntry 3 }
agentPethPseCardHost OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the board which hosts the PoE daughther card at PSE side."
::= { agentPethPseEntry 4 }
agentPethPseCardStatus OBJECT-TYPE
SYNTAX INTEGER {
absent-or-failed(0),
running(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays running status of the PoE daughther card at PSE side. The value
absent-or-failed(0) means that the card is either not present or some error has occurred.
The value running(1) means that card is present and working fine."
::= { agentPethPseEntry 5 }
END