RUGGEDCOM-SYS-INFO-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-IDENTITY,
|
|
OBJECT-TYPE, Integer32 FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, TruthValue,
|
|
DisplayString FROM SNMPv2-TC
|
|
OBJECT-GROUP FROM SNMPv2-CONF
|
|
ruggedcomMgmt FROM RUGGEDCOM-MIB;
|
|
|
|
rcSysInfo MODULE-IDENTITY
|
|
LAST-UPDATED "201711021000Z" -- Nov. 02, 10:00 EST 2017
|
|
ORGANIZATION "Siemens Canada Ltd., Process Industries and Drives"
|
|
CONTACT-INFO
|
|
"Postal: Siemens Canad Ltd.
|
|
300 Applewood Crescent
|
|
Concord, Ontario,
|
|
L4K 5C7 Canada
|
|
Tel: 1-905-856-5288
|
|
E-Mail: support.canada.automation@siemens.com"
|
|
|
|
DESCRIPTION
|
|
"RuggedCom system information MIB."
|
|
|
|
REVISION "201711021000Z" -- Nov. 02, 10:00 EST 2017
|
|
DESCRIPTION
|
|
"Added new object rcDeviceErrSystem."
|
|
|
|
REVISION "201709201100Z" -- Sept. 20, 11:00 EST 2017
|
|
DESCRIPTION
|
|
"Updated DESCRIPTION of objects rcDeviceErrRadiusServerUnreachable and
|
|
rcDeviceErrTacacsServerUnreachable."
|
|
|
|
REVISION "201702151000Z" -- Feb 15, 10:00 EST 2017
|
|
DESCRIPTION
|
|
"Updated ORGANIZATION and CONTACT-INFO. Updated DESCRIPTION of
|
|
object rcDeviceErrNtpServerUnreachable."
|
|
|
|
REVISION "201410081700Z" -- Oct 08, 17:00 EST 2014
|
|
DESCRIPTION
|
|
"Added new board IDs in RcMainBoard TEXTUAL-CONVENTION."
|
|
|
|
REVISION "201208301700Z" -- Aug 30, 17:00 EST 2012
|
|
DESCRIPTION
|
|
"Added new objects: rcDeviceStsKeysDflt and rcDeviceInfoMinBootSwVer
|
|
related to the device security in the group
|
|
rcSysDeviceSecurityGroup01."
|
|
|
|
REVISION "201206011700Z" -- Jun 01, 17:00 EST 2012
|
|
|
|
DESCRIPTION
|
|
"Added new objects rcDeviceStsPwdsWeak related to the device
|
|
security in the group rcSysDeviceSecurityGroup."
|
|
|
|
REVISION "201104051000Z" -- Apr 05, 10:00 EST 2011
|
|
DESCRIPTION
|
|
"Extended RcHardwareStatus textual convention. Added
|
|
'notConnected(4)' value."
|
|
|
|
REVISION "201009161300Z" -- Sep 16, 13:00 EST 2010
|
|
DESCRIPTION
|
|
"Added Fan Bank Module hardware status elements.
|
|
Added new objects:
|
|
rcDeviceStsFanBank1 and rcDeviceStsFanBank2
|
|
Added new types related to module Slot and state change."
|
|
|
|
REVISION "200905171300Z" -- May 17, 13:00 EST 2009
|
|
DESCRIPTION
|
|
"Fixed description for object rcDeviceCommClearSyslog.
|
|
Added new object:
|
|
rcDeviceCommClearLogs
|
|
Removed statement about mandatory groups from groups descriptions."
|
|
|
|
|
|
REVISION "200812171300Z" -- Dec 17, 13:00 EST 2008
|
|
DESCRIPTION
|
|
"Fixed mistyped object name for rcDeviceStsErrorAlarm in
|
|
rcSysStsObjectsGroup objects list.
|
|
Added new object:
|
|
rcDeviceCommIdentify."
|
|
|
|
REVISION "200810091000Z" -- Oct 09, 10:00 EST 2008
|
|
DESCRIPTION
|
|
"Added new objects:
|
|
rcDeviceStsErrorAlarm,
|
|
rcDeviceStsFailSafeRelay,
|
|
rcDeviceStsNoOfActiveAlarms."
|
|
|
|
REVISION "200809121400Z" -- Sep 12, 14:00 EST 2008
|
|
DESCRIPTION
|
|
"Adde new enumeration labels for rcDeviceInfoMainBoardType
|
|
for new hardware platform support."
|
|
|
|
REVISION "200802151400Z" -- Feb 15, 14:00 EST 2008
|
|
DESCRIPTION
|
|
"Removed '_' characters from enumeration labels.
|
|
Added new objects:
|
|
rcDeviceInfoPendingBootSwVersion
|
|
rcDeviceInfoPendingMainSwVersion
|
|
rcDeviceInfoCfgRevision
|
|
rcDeviceCommReset
|
|
rcDeviceCommLoadDefaultCfg,
|
|
rcDeviceCommClearAlarms,
|
|
rcDeviceCommClearSyslog
|
|
"
|
|
|
|
REVISION "200609061400Z" -- Sept 6, 14:00 EST 2006
|
|
DESCRIPTION
|
|
"The initial version of RuggedCom system information MIB."
|
|
::= { ruggedcomMgmt 2 }
|
|
|
|
RcHardwareStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A status of a hardware module in the RuggedCom device."
|
|
SYNTAX INTEGER {
|
|
notPresent(1), -- the module is not present
|
|
functional(2), -- the module is present and functional
|
|
notFunctional(3), -- the module is present, but not
|
|
-- functional
|
|
notConnected(4) -- the module is present, but not connected
|
|
}
|
|
|
|
RcFanStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of a fan-bank."
|
|
SYNTAX INTEGER {
|
|
notPresent(1), -- this bank is not present
|
|
failed(2), -- this bank has failed due to a mechanical
|
|
-- or sensor problem
|
|
standby(3), -- the fan system is active, but this bank
|
|
-- is designated as a backup and not
|
|
off(4), -- currently spinning this bank is off
|
|
on(5) -- this bank is currently spinning
|
|
}
|
|
|
|
RcHotswapModuleSlot ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A physical slot holding the hotswapable module (ROX 2 specific).
|
|
As the value 0 is forbidden in SNMP enumerations, this value is the
|
|
value 1 higher than some other ROX 2 slot values"
|
|
SYNTAX INTEGER {
|
|
pm1(1),
|
|
lm1(2),
|
|
lm2(3),
|
|
lm3(4),
|
|
cm(5),
|
|
sm(6),
|
|
lm4(7),
|
|
lm5(8),
|
|
lm6(9),
|
|
pm2(10),
|
|
main(11), -- The backplane is not hotswapable
|
|
em(12) -- This is a logical slot not a physical one,
|
|
-- not hotswapable
|
|
}
|
|
|
|
RcHotswapModuleState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A status of a hardware module in the RuggedCom device."
|
|
SYNTAX INTEGER {
|
|
empty(1), -- the module is not present
|
|
disabled(2), -- the module is present, but has been
|
|
-- disabled by configuration.
|
|
resetting(3), -- the module is present and is on its way
|
|
-- to either operating or failed.
|
|
operating(4), -- the module is present and has reached
|
|
-- the operating state
|
|
failed(5), -- the module is present, but cannot be
|
|
unknown(255) -- booted unknown status
|
|
}
|
|
|
|
|
|
|
|
RcMainBoard ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A main board type code. This textual convention will be updated
|
|
any time when new main board type is developed."
|
|
SYNTAX INTEGER {
|
|
rsMCPU2(1), -- RSMCPU, otherwise known as
|
|
-- 40-00-0026 Rev A1
|
|
rs400revB2(2),
|
|
rmc30(3),
|
|
rs900revB1F(4), -- RS900 with 6 copper,
|
|
-- 2 fiber and 1 optional port
|
|
rs900revB1noF(5), -- RS900 with 8 copper and 1
|
|
-- optional port
|
|
rs1600M(6), -- RS1600 Modular, obsolete
|
|
rs400revC1(7),
|
|
rsG2100(8),
|
|
rs900G(9),
|
|
rsG2200(10),
|
|
rs969(11),
|
|
rs900v2F(12), -- RS900 88E6095 based with
|
|
-- 6 copper, 2 fiber and
|
|
rs900v2noF(13), -- 1 optional port RS900
|
|
-- 88E6095 based with 8 copper
|
|
-- and 1 optional port
|
|
rs416(15),
|
|
rsRMC30Ksz80001(16),
|
|
rs930(17),
|
|
rs969v2(18),
|
|
rs910(19),
|
|
rs920(20),
|
|
rs940G(21),
|
|
rsi80x(22),
|
|
rsG2300(23),
|
|
rs416v2(24),
|
|
rsg2288(25),
|
|
rp110(26),
|
|
rs900GP(27),
|
|
rs900M(28),
|
|
rs950G(29),
|
|
rsG2488(61),
|
|
rsG2488v2(62),
|
|
rsG2488v3(63),
|
|
rmc8388A(64),
|
|
rmc8388B(65),
|
|
rmc8388C(66),
|
|
rsG920P(67),
|
|
rsMCPU(255), -- RSMCPU, otherwise known
|
|
-- as 40-00-0008 Rev B1
|
|
rx1000(256),
|
|
rx1100(257),
|
|
rx1500(258),
|
|
rx1501(259),
|
|
rx1510(260),
|
|
rx1511(261),
|
|
rx1512(262),
|
|
rx5000(263),
|
|
mx5000(264),
|
|
rx1400(265)
|
|
}
|
|
|
|
|
|
rcSysInfoConformance OBJECT IDENTIFIER ::= { rcSysInfo 5 }
|
|
-- rcSysInfoCompliances OBJECT IDENTIFIER ::= { rcSysInfoConformance 1 }
|
|
rcSysInfoGroups OBJECT IDENTIFIER ::= { rcSysInfoConformance 2 }
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- SysInfo subtrees
|
|
-- ---------------------------------------------------------------------- --
|
|
|
|
|
|
rcDeviceError OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main subtree for various errors detected in RuggedCom devices."
|
|
::= { rcSysInfo 1 }
|
|
|
|
rcDeviceStatus OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main subtree for various status information detected in
|
|
RuggedCom devices."
|
|
::= { rcSysInfo 2 }
|
|
|
|
rcDeviceInfo OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main subtree for RuggedCom devices manufacturing information."
|
|
::= { rcSysInfo 3 }
|
|
|
|
rcDeviceCommands OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main subtree for device control commands."
|
|
::= { rcSysInfo 4 }
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- Device errors objects
|
|
-- ---------------------------------------------------------------------- --
|
|
|
|
rcDeviceErrBootupError OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The error discovered during bootup process.
|
|
If there was no error during device bootup, zero length string
|
|
will be retreived."
|
|
::= { rcDeviceError 1}
|
|
|
|
rcDeviceErrWatchdogReset OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Indicates whether the last device reboot was caused by wachdog."
|
|
::= { rcDeviceError 2}
|
|
|
|
rcDeviceErrConfigurationFailure OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Indicates whether errors were detected while applying configuration
|
|
settings from configuration file.
|
|
Configuration is updated from the configureation file at bootup time
|
|
when file is loaded from nonvolatile memory, or when new file is
|
|
downloaded to the device.
|
|
Whenever the value of this object changes from false(2) to true(1),
|
|
the device will generate genericTrap notification."
|
|
REFERENCE
|
|
"genericTrap notification is defined in ruggedcomTrapsModule."
|
|
::= { rcDeviceError 3}
|
|
|
|
rcDeviceErrCrashLogCreated OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Indicates whether the device error that caused creation of an
|
|
entry in crashlog.txt file was detected.
|
|
Whenever the value of this object changes from false(2) to true(1),
|
|
the device will generate genericTrap notification."
|
|
REFERENCE
|
|
"genericTrap notification is defined in ruggedcomTrapsModule."
|
|
::= { rcDeviceError 4}
|
|
|
|
rcDeviceErrStackOverflow OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Indicates whether the stack of any of the system tasks is used
|
|
over the system threshold.
|
|
Whenever the value of this object changes from false(2) to true(1),
|
|
the device will generate genericTrap notification."
|
|
REFERENCE
|
|
"genericTrap notification is defined in ruggedcomTrapsModule."
|
|
::= { rcDeviceError 5}
|
|
|
|
rcDeviceErrHeapError OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Indicates whether the system memory corruption was detected.
|
|
Whenever the value of this object changes from false(2) to true(1),
|
|
the device will generate genericTrap notification."
|
|
REFERENCE
|
|
"genericTrap notification is defined in ruggedcomTrapsModule."
|
|
::= { rcDeviceError 6}
|
|
|
|
rcDeviceErrDateAndTimeSetFailed OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Indicates whether the date and time setting in the device falied.
|
|
Whenever the value of this object changes from false(2) to true(1),
|
|
the device will generate genericTrap notification."
|
|
REFERENCE
|
|
"genericTrap notification is defined in ruggedcomTrapsModule."
|
|
::= { rcDeviceError 7}
|
|
|
|
rcDeviceErrNtpServerUnreachable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether any of NTP servers (if required) can be reached.
|
|
The value of this object is 'false' if both servers become unreachable.
|
|
Whenever the value of this object changes, the device will generate
|
|
the ntpServiceAvailableChange notification."
|
|
REFERENCE
|
|
"ntpServiceAvailableChange notification is defined in RUGGEDCOM-NTP-MIB file."
|
|
::= { rcDeviceError 8 }
|
|
|
|
rcDeviceErrBootPTftpTrFailed OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the the file was transfered properly after
|
|
obtaining IP address from the BootP server.
|
|
Whenever the value of this object changes from false(2) to true(1),
|
|
the device will generate genericTrap notification."
|
|
REFERENCE
|
|
"genericTrap notification is defined in ruggedcomTrapsModule."
|
|
::= { rcDeviceError 9 }
|
|
|
|
rcDeviceErrRadiusServerUnreachable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the RADIUS server (if required) can be reached.
|
|
Whenever the value of this object changes, the device will generate
|
|
the radiusServiceAvailableChange notification."
|
|
REFERENCE
|
|
"radiusServiceAvailableChange notification is defined in ruggedcomTrapsModule."
|
|
::= { rcDeviceError 10 }
|
|
|
|
rcDeviceErrTacacsServerUnreachable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the TACACS+ server (if required) can be reached.
|
|
Whenever the value of this object changes, the device will generate
|
|
the tacacsServiceAvailableChange notification."
|
|
REFERENCE
|
|
"tacacsServiceAvailableChange notification is defined in ruggedcomTrapsModule."
|
|
::= { rcDeviceError 11 }
|
|
|
|
|
|
rcDeviceErrSystem OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
errCrashLog(0),
|
|
errWatchdogRst(1),
|
|
errBootupErr(2),
|
|
errCfgFailure(3),
|
|
errStackOvfl(4),
|
|
errHeapErr(5),
|
|
errRealTimeClk(6),
|
|
errRxBuffersLow(7),
|
|
errClockManager_OutOfResources(8),
|
|
errClockManager_PrimarySourceFailed(9),
|
|
errFpgaCompatibility(10),
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicated whether a device failure occured. Whenever the value of this object
|
|
changes, the device will generate the deviceErrTrap notification."
|
|
REFERENCE
|
|
"deviceErrTrap notification is defined in ruggedcomTrapsModule."
|
|
::= {rcDeviceError 12 }
|
|
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- Device Status information objects
|
|
-- ---------------------------------------------------------------------- --
|
|
|
|
rcDeviceStsCpuUsage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "tenths of percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage in tenths of percent of available CPU cycles used
|
|
for device operation as measured over the last second when
|
|
object was retreived."
|
|
::= { rcDeviceStatus 1 }
|
|
|
|
rcDeviceStsAvailableRam OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of bytes of RAM still available in the system
|
|
control CPU."
|
|
::= { rcDeviceStatus 2 }
|
|
|
|
rcDeviceStsTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "Celsius degrees"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature measured in the device."
|
|
::= { rcDeviceStatus 3 }
|
|
|
|
rcDeviceStsPowerSupply1 OBJECT-TYPE
|
|
SYNTAX RcHardwareStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the status of Power Supply Module 1.
|
|
Whenever the value of this object changes from functional(2) to
|
|
notFunctional(3), or from notFunctionl(3) to functional(2),
|
|
the device will generate powerSupplyTrap notification."
|
|
REFERENCE
|
|
"powerSupplyTrap notification is defined in ruggedcomTrapsModule."
|
|
::= { rcDeviceStatus 4 }
|
|
|
|
rcDeviceStsPowerSupply2 OBJECT-TYPE
|
|
SYNTAX RcHardwareStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the status of Power Supply Module 2.
|
|
Whenever the value of this object changes from functional(2) to
|
|
notFunctional(3), or from notFunctionl(3) to functional(2),
|
|
the device will generate powerSupplyTrap notification."
|
|
REFERENCE
|
|
"powerSupplyTrap notification is defined in ruggedcomTrapsModule."
|
|
::= { rcDeviceStatus 5 }
|
|
|
|
rcDeviceStsCpuUsagePercent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of available CPU cycles used for device operation
|
|
as measured over the last second when object was retreived."
|
|
::= { rcDeviceStatus 6 }
|
|
|
|
|
|
rcDeviceStsFailSafeRelay OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
energized(1),
|
|
deEnergized(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates status of fail safe relay in the device.
|
|
Fail safe relay is deEnergized(2) if there is at least one active
|
|
alarm recorded in the device."
|
|
::= { rcDeviceStatus 7 }
|
|
|
|
|
|
rcDeviceStsErrorAlarm OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates that at least one alarm of level ERROR, ALERT or CRITICAL
|
|
is active in the device."
|
|
::= { rcDeviceStatus 8 }
|
|
|
|
|
|
rcDeviceStsNoOfActiveAlarms OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of active alarms currently recorded in device."
|
|
::= { rcDeviceStatus 9 }
|
|
|
|
rcDeviceStsFanBank1 OBJECT-TYPE
|
|
SYNTAX RcFanStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the status of Fan Bank Module 1."
|
|
REFERENCE
|
|
"fanBankTrap notification is defined in ruggedcomTrapsModule."
|
|
::= { rcDeviceStatus 10 }
|
|
|
|
rcDeviceStsFanBank2 OBJECT-TYPE
|
|
SYNTAX RcFanStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the status of Fan Bank Module 2."
|
|
REFERENCE
|
|
"fanBankTrap notification is defined in ruggedcomTrapsModule."
|
|
::= { rcDeviceStatus 11 }
|
|
|
|
rcDeviceStsPwdsWeak OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
adminPwd(0),
|
|
operPwd(1),
|
|
guestPwd(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if any of passwords is configured as 'weak'.
|
|
Change in the value of the bit in this object from '0' to '1'
|
|
will generate weakPasswordTrap."
|
|
REFERENCE
|
|
"weakPasswordTrap notification is defined in ruggedcomTrapsModule."
|
|
::= { rcDeviceStatus 12 }
|
|
|
|
rcDeviceStsKeysDflt OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
sshDfltKeys(0),
|
|
sslDfltKeys(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if any of secure services uses default keys and/or
|
|
certificates. Customer is advised to update keys for secure
|
|
services if defaults are used.
|
|
Change in the value of the bit in this object from '0' to '1'
|
|
will generate defaultKeysTrap notification."
|
|
REFERENCE
|
|
"defaultKeysTrap notification is defined in ruggedcomTrapsModule."
|
|
::= { rcDeviceStatus 13 }
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- General System Information objects
|
|
-- ---------------------------------------------------------------------- --
|
|
|
|
rcDeviceInfoSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturing serial number of the device."
|
|
::= { rcDeviceInfo 1 }
|
|
|
|
rcDeviceInfoBootSwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version and the build date of the boot loader software."
|
|
::= { rcDeviceInfo 2 }
|
|
|
|
rcDeviceInfoMainSwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version and the build date of the main operating system
|
|
software."
|
|
::= { rcDeviceInfo 3 }
|
|
|
|
rcDeviceInfoMainBoardType OBJECT-TYPE
|
|
SYNTAX RcMainBoard
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The identification code of the device main board."
|
|
::= { rcDeviceInfo 4 }
|
|
|
|
rcDeviceInfoTotalRam OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of bytes of RAM in the system control CPU."
|
|
::= { rcDeviceInfo 5 }
|
|
|
|
rcDeviceInfoPendingBootSwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version and the build date of the boot loader software
|
|
that has been loaded to the device and is pending reboot.
|
|
Whenever the value of this object changes from zero-length string
|
|
to any string of non-zero length, the device will generate
|
|
swUpgradeTrap notification."
|
|
REFERENCE
|
|
"swUpgradeTrap notification is defined in ruggedcomTrapsModule."
|
|
::= { rcDeviceInfo 6 }
|
|
|
|
rcDeviceInfoPendingMainSwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version and the build date of the main operating system
|
|
software that has been loaded to the device and is pending reboot.
|
|
Whenever the value of this object changes from zero-length string
|
|
to any string of non-zero length, the device will generate
|
|
swUpgradeTrap notification."
|
|
REFERENCE
|
|
"swUpgradeTrap notification is defined in ruggedcomTrapsModule."
|
|
::= { rcDeviceInfo 7 }
|
|
|
|
rcDeviceInfoCfgRevision OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The configuration file revision.
|
|
The revision number will be updated whenever file is saved to the
|
|
flash memory. This number is recorded in config.csv at the time file
|
|
is uploaded from the device.
|
|
Whenever the value of this object changes the device will generate
|
|
cfgChangeTrap notification."
|
|
REFERENCE
|
|
"cfgChangeTrap notification is defined in ruggedcomTrapsModule."
|
|
::= { rcDeviceInfo 8 }
|
|
|
|
rcDeviceInfoMinBootSwVer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum version of the boot loader software required by
|
|
ROS device. If this version is not newer than the version
|
|
retreived as a value of object rcDeviceInfoBootSwVersion, trap
|
|
bootVersionMismatchTrap will be generated."
|
|
|
|
REFERENCE
|
|
"bootVersionMismatchTrap notification is defined in
|
|
ruggedcomTrapsModule."
|
|
::= { rcDeviceInfo 9 }
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- Device control commands objects
|
|
-- ---------------------------------------------------------------------- --
|
|
|
|
rcDeviceCommReset OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the value of this object to 'true(1)' will cause device
|
|
to reboot.
|
|
As a result of Read request the agent will return value 'false(2)'."
|
|
::= { rcDeviceCommands 1}
|
|
|
|
rcDeviceCommLoadDefaultCfg OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the value of this object to 'true(1)' will force device
|
|
to load default configuration to all tables.
|
|
As a result of Read request the agent will return value 'false(2)'."
|
|
::= { rcDeviceCommands 2}
|
|
|
|
rcDeviceCommClearAlarms OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the value of this object to 'true(1)' will cause device
|
|
to clear all alarms.
|
|
As a result of Read request the agent will return value 'false(2)'."
|
|
::= { rcDeviceCommands 3}
|
|
|
|
rcDeviceCommClearSyslog OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the value of this object to 'true(1)' will cause device
|
|
to clear syslog.txt file.
|
|
As a result of Read request the agent will return value 'false(2)'."
|
|
::= { rcDeviceCommands 4}
|
|
|
|
rcDeviceCommClearLogs OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting the value of this object to 'true(1)' will cause device
|
|
to clear syslog.txt and crashlog.txt files.
|
|
As a result of Read request the agent will return value 'false(2)'."
|
|
::= { rcDeviceCommands 5}
|
|
|
|
rcDeviceCommIdentify OBJECT-TYPE
|
|
SYNTAX Integer32 (0..300)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time Period in seconds for which the device should continue flashing
|
|
the LEDs when possible so that device is visually recognized.
|
|
Setting this value to any value greater than 0 will start LED flash
|
|
timer on the device.Setting the value to 0 will stop the LED flash
|
|
timer. On Read request agent always sends back the existing Timeout
|
|
value for LED flash Timer."
|
|
::= { rcDeviceCommands 6 }
|
|
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
-- Object Groups
|
|
-- ---------------------------------------------------------------------- --
|
|
|
|
rcSysErrObjectsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcDeviceErrBootupError,
|
|
rcDeviceErrWatchdogReset,
|
|
rcDeviceErrConfigurationFailure,
|
|
rcDeviceErrCrashLogCreated,
|
|
rcDeviceErrStackOverflow,
|
|
rcDeviceErrHeapError,
|
|
rcDeviceErrDateAndTimeSetFailed,
|
|
rcDeviceErrNtpServerUnreachable,
|
|
rcDeviceErrBootPTftpTrFailed,
|
|
rcDeviceErrRadiusServerUnreachable,
|
|
rcDeviceErrTacacsServerUnreachable
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"A group of objects providing information about irregularities
|
|
in the device."
|
|
::= { rcSysInfoGroups 1 }
|
|
|
|
rcSysStsObjectsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcDeviceStsCpuUsage,
|
|
rcDeviceStsCpuUsagePercent,
|
|
rcDeviceStsAvailableRam
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"A group of objects providing information device resources."
|
|
::= { rcSysInfoGroups 2 }
|
|
|
|
|
|
rcSysStsObjectsTemperatureGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcDeviceStsTemperature
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This group is created to allow MIBs for products that do not have
|
|
temperature sensore installed to exclude rcDeviceStsTemperature
|
|
object."
|
|
::= { rcSysInfoGroups 3 }
|
|
|
|
rcSysStsPowerSupplyGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcDeviceStsPowerSupply1,
|
|
rcDeviceStsPowerSupply2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A group of objects providing information about power supply modules
|
|
in the device. This group is mandatory for products with redundant
|
|
power supply."
|
|
::= { rcSysInfoGroups 4 }
|
|
|
|
rcSysInfoDeviceInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcDeviceInfoMainBoardType,
|
|
rcDeviceInfoTotalRam,
|
|
rcDeviceInfoBootSwVersion,
|
|
rcDeviceInfoMainSwVersion,
|
|
rcDeviceInfoPendingBootSwVersion,
|
|
rcDeviceInfoPendingMainSwVersion,
|
|
rcDeviceInfoCfgRevision,
|
|
rcDeviceInfoSerialNumber
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A group of object providing manufacturer's information about
|
|
product's main board hardware, software, identification."
|
|
::= { rcSysInfoGroups 5 }
|
|
|
|
rcSysDeviceCommGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcDeviceCommReset,
|
|
rcDeviceCommLoadDefaultCfg,
|
|
rcDeviceCommClearAlarms,
|
|
rcDeviceCommClearSyslog,
|
|
rcDeviceCommClearLogs
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A group of object providing device control commands."
|
|
::= { rcSysInfoGroups 6 }
|
|
|
|
rcSysDeviceCommIdentifyGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcDeviceCommIdentify
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A group of object providing device control commands for
|
|
visual recognisation of the device (LED flashing)."
|
|
::= { rcSysInfoGroups 7 }
|
|
|
|
|
|
|
|
rcSysStsObjectsGroup1 OBJECT-GROUP
|
|
OBJECTS {
|
|
rcDeviceStsCpuUsage,
|
|
rcDeviceStsCpuUsagePercent,
|
|
rcDeviceStsAvailableRam,
|
|
rcDeviceStsErrorAlarm,
|
|
rcDeviceStsFailSafeRelay,
|
|
rcDeviceStsNoOfActiveAlarms
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A group of objects providing information about device resources."
|
|
::= { rcSysInfoGroups 8 }
|
|
|
|
|
|
rcSysStsFanBankGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcDeviceStsFanBank1,
|
|
rcDeviceStsFanBank2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A group of objects providing information about fan bank modules
|
|
in the device. This group is mandatory for products with redundant
|
|
fan banks."
|
|
::= { rcSysInfoGroups 9 }
|
|
|
|
|
|
rcSysDeviceSecurityGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
rcDeviceStsPwdsWeak
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A group of object providing device control commands."
|
|
::= { rcSysInfoGroups 10 }
|
|
|
|
rcSysDeviceSecurityGroup01 OBJECT-GROUP
|
|
OBJECTS {
|
|
rcDeviceStsPwdsWeak,
|
|
rcDeviceStsKeysDflt,
|
|
rcDeviceInfoMinBootSwVer
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A group of object providing device control commands."
|
|
::= { rcSysInfoGroups 11 }
|
|
|
|
rcSysErrObjectsGroup1 OBJECT-GROUP
|
|
OBJECTS {
|
|
rcDeviceErrSystem
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A group of objects providing information about device system errors."
|
|
::= { rcSysInfoGroups 12 }
|
|
|
|
END
|