mibs/MIBS/ros/RUGGEDCOM-SYS-INFO-MIB
2023-12-05 12:25:34 +01:00

922 lines
31 KiB
Plaintext

RUGGEDCOM-SYS-INFO-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-IDENTITY,
OBJECT-TYPE, Integer32 FROM SNMPv2-SMI
TEXTUAL-CONVENTION, TruthValue,
DisplayString FROM SNMPv2-TC
OBJECT-GROUP FROM SNMPv2-CONF
ruggedcomMgmt FROM RUGGEDCOM-MIB;
rcSysInfo MODULE-IDENTITY
LAST-UPDATED "201711021000Z" -- Nov. 02, 10:00 EST 2017
ORGANIZATION "Siemens Canada Ltd., Process Industries and Drives"
CONTACT-INFO
"Postal: Siemens Canad Ltd.
300 Applewood Crescent
Concord, Ontario,
L4K 5C7 Canada
Tel: 1-905-856-5288
E-Mail: support.canada.automation@siemens.com"
DESCRIPTION
"RuggedCom system information MIB."
REVISION "201711021000Z" -- Nov. 02, 10:00 EST 2017
DESCRIPTION
"Added new object rcDeviceErrSystem."
REVISION "201709201100Z" -- Sept. 20, 11:00 EST 2017
DESCRIPTION
"Updated DESCRIPTION of objects rcDeviceErrRadiusServerUnreachable and
rcDeviceErrTacacsServerUnreachable."
REVISION "201702151000Z" -- Feb 15, 10:00 EST 2017
DESCRIPTION
"Updated ORGANIZATION and CONTACT-INFO. Updated DESCRIPTION of
object rcDeviceErrNtpServerUnreachable."
REVISION "201410081700Z" -- Oct 08, 17:00 EST 2014
DESCRIPTION
"Added new board IDs in RcMainBoard TEXTUAL-CONVENTION."
REVISION "201208301700Z" -- Aug 30, 17:00 EST 2012
DESCRIPTION
"Added new objects: rcDeviceStsKeysDflt and rcDeviceInfoMinBootSwVer
related to the device security in the group
rcSysDeviceSecurityGroup01."
REVISION "201206011700Z" -- Jun 01, 17:00 EST 2012
DESCRIPTION
"Added new objects rcDeviceStsPwdsWeak related to the device
security in the group rcSysDeviceSecurityGroup."
REVISION "201104051000Z" -- Apr 05, 10:00 EST 2011
DESCRIPTION
"Extended RcHardwareStatus textual convention. Added
'notConnected(4)' value."
REVISION "201009161300Z" -- Sep 16, 13:00 EST 2010
DESCRIPTION
"Added Fan Bank Module hardware status elements.
Added new objects:
rcDeviceStsFanBank1 and rcDeviceStsFanBank2
Added new types related to module Slot and state change."
REVISION "200905171300Z" -- May 17, 13:00 EST 2009
DESCRIPTION
"Fixed description for object rcDeviceCommClearSyslog.
Added new object:
rcDeviceCommClearLogs
Removed statement about mandatory groups from groups descriptions."
REVISION "200812171300Z" -- Dec 17, 13:00 EST 2008
DESCRIPTION
"Fixed mistyped object name for rcDeviceStsErrorAlarm in
rcSysStsObjectsGroup objects list.
Added new object:
rcDeviceCommIdentify."
REVISION "200810091000Z" -- Oct 09, 10:00 EST 2008
DESCRIPTION
"Added new objects:
rcDeviceStsErrorAlarm,
rcDeviceStsFailSafeRelay,
rcDeviceStsNoOfActiveAlarms."
REVISION "200809121400Z" -- Sep 12, 14:00 EST 2008
DESCRIPTION
"Adde new enumeration labels for rcDeviceInfoMainBoardType
for new hardware platform support."
REVISION "200802151400Z" -- Feb 15, 14:00 EST 2008
DESCRIPTION
"Removed '_' characters from enumeration labels.
Added new objects:
rcDeviceInfoPendingBootSwVersion
rcDeviceInfoPendingMainSwVersion
rcDeviceInfoCfgRevision
rcDeviceCommReset
rcDeviceCommLoadDefaultCfg,
rcDeviceCommClearAlarms,
rcDeviceCommClearSyslog
"
REVISION "200609061400Z" -- Sept 6, 14:00 EST 2006
DESCRIPTION
"The initial version of RuggedCom system information MIB."
::= { ruggedcomMgmt 2 }
RcHardwareStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A status of a hardware module in the RuggedCom device."
SYNTAX INTEGER {
notPresent(1), -- the module is not present
functional(2), -- the module is present and functional
notFunctional(3), -- the module is present, but not
-- functional
notConnected(4) -- the module is present, but not connected
}
RcFanStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The status of a fan-bank."
SYNTAX INTEGER {
notPresent(1), -- this bank is not present
failed(2), -- this bank has failed due to a mechanical
-- or sensor problem
standby(3), -- the fan system is active, but this bank
-- is designated as a backup and not
off(4), -- currently spinning this bank is off
on(5) -- this bank is currently spinning
}
RcHotswapModuleSlot ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A physical slot holding the hotswapable module (ROX 2 specific).
As the value 0 is forbidden in SNMP enumerations, this value is the
value 1 higher than some other ROX 2 slot values"
SYNTAX INTEGER {
pm1(1),
lm1(2),
lm2(3),
lm3(4),
cm(5),
sm(6),
lm4(7),
lm5(8),
lm6(9),
pm2(10),
main(11), -- The backplane is not hotswapable
em(12) -- This is a logical slot not a physical one,
-- not hotswapable
}
RcHotswapModuleState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A status of a hardware module in the RuggedCom device."
SYNTAX INTEGER {
empty(1), -- the module is not present
disabled(2), -- the module is present, but has been
-- disabled by configuration.
resetting(3), -- the module is present and is on its way
-- to either operating or failed.
operating(4), -- the module is present and has reached
-- the operating state
failed(5), -- the module is present, but cannot be
unknown(255) -- booted unknown status
}
RcMainBoard ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A main board type code. This textual convention will be updated
any time when new main board type is developed."
SYNTAX INTEGER {
rsMCPU2(1), -- RSMCPU, otherwise known as
-- 40-00-0026 Rev A1
rs400revB2(2),
rmc30(3),
rs900revB1F(4), -- RS900 with 6 copper,
-- 2 fiber and 1 optional port
rs900revB1noF(5), -- RS900 with 8 copper and 1
-- optional port
rs1600M(6), -- RS1600 Modular, obsolete
rs400revC1(7),
rsG2100(8),
rs900G(9),
rsG2200(10),
rs969(11),
rs900v2F(12), -- RS900 88E6095 based with
-- 6 copper, 2 fiber and
rs900v2noF(13), -- 1 optional port RS900
-- 88E6095 based with 8 copper
-- and 1 optional port
rs416(15),
rsRMC30Ksz80001(16),
rs930(17),
rs969v2(18),
rs910(19),
rs920(20),
rs940G(21),
rsi80x(22),
rsG2300(23),
rs416v2(24),
rsg2288(25),
rp110(26),
rs900GP(27),
rs900M(28),
rs950G(29),
rsG2488(61),
rsG2488v2(62),
rsG2488v3(63),
rmc8388A(64),
rmc8388B(65),
rmc8388C(66),
rsG920P(67),
rsMCPU(255), -- RSMCPU, otherwise known
-- as 40-00-0008 Rev B1
rx1000(256),
rx1100(257),
rx1500(258),
rx1501(259),
rx1510(260),
rx1511(261),
rx1512(262),
rx5000(263),
mx5000(264),
rx1400(265)
}
rcSysInfoConformance OBJECT IDENTIFIER ::= { rcSysInfo 5 }
-- rcSysInfoCompliances OBJECT IDENTIFIER ::= { rcSysInfoConformance 1 }
rcSysInfoGroups OBJECT IDENTIFIER ::= { rcSysInfoConformance 2 }
-- ---------------------------------------------------------------------- --
-- SysInfo subtrees
-- ---------------------------------------------------------------------- --
rcDeviceError OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The main subtree for various errors detected in RuggedCom devices."
::= { rcSysInfo 1 }
rcDeviceStatus OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The main subtree for various status information detected in
RuggedCom devices."
::= { rcSysInfo 2 }
rcDeviceInfo OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The main subtree for RuggedCom devices manufacturing information."
::= { rcSysInfo 3 }
rcDeviceCommands OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The main subtree for device control commands."
::= { rcSysInfo 4 }
-- ---------------------------------------------------------------------- --
-- Device errors objects
-- ---------------------------------------------------------------------- --
rcDeviceErrBootupError OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The error discovered during bootup process.
If there was no error during device bootup, zero length string
will be retreived."
::= { rcDeviceError 1}
rcDeviceErrWatchdogReset OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Indicates whether the last device reboot was caused by wachdog."
::= { rcDeviceError 2}
rcDeviceErrConfigurationFailure OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Indicates whether errors were detected while applying configuration
settings from configuration file.
Configuration is updated from the configureation file at bootup time
when file is loaded from nonvolatile memory, or when new file is
downloaded to the device.
Whenever the value of this object changes from false(2) to true(1),
the device will generate genericTrap notification."
REFERENCE
"genericTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceError 3}
rcDeviceErrCrashLogCreated OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Indicates whether the device error that caused creation of an
entry in crashlog.txt file was detected.
Whenever the value of this object changes from false(2) to true(1),
the device will generate genericTrap notification."
REFERENCE
"genericTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceError 4}
rcDeviceErrStackOverflow OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Indicates whether the stack of any of the system tasks is used
over the system threshold.
Whenever the value of this object changes from false(2) to true(1),
the device will generate genericTrap notification."
REFERENCE
"genericTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceError 5}
rcDeviceErrHeapError OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Indicates whether the system memory corruption was detected.
Whenever the value of this object changes from false(2) to true(1),
the device will generate genericTrap notification."
REFERENCE
"genericTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceError 6}
rcDeviceErrDateAndTimeSetFailed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Indicates whether the date and time setting in the device falied.
Whenever the value of this object changes from false(2) to true(1),
the device will generate genericTrap notification."
REFERENCE
"genericTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceError 7}
rcDeviceErrNtpServerUnreachable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether any of NTP servers (if required) can be reached.
The value of this object is 'false' if both servers become unreachable.
Whenever the value of this object changes, the device will generate
the ntpServiceAvailableChange notification."
REFERENCE
"ntpServiceAvailableChange notification is defined in RUGGEDCOM-NTP-MIB file."
::= { rcDeviceError 8 }
rcDeviceErrBootPTftpTrFailed OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the the file was transfered properly after
obtaining IP address from the BootP server.
Whenever the value of this object changes from false(2) to true(1),
the device will generate genericTrap notification."
REFERENCE
"genericTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceError 9 }
rcDeviceErrRadiusServerUnreachable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the RADIUS server (if required) can be reached.
Whenever the value of this object changes, the device will generate
the radiusServiceAvailableChange notification."
REFERENCE
"radiusServiceAvailableChange notification is defined in ruggedcomTrapsModule."
::= { rcDeviceError 10 }
rcDeviceErrTacacsServerUnreachable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the TACACS+ server (if required) can be reached.
Whenever the value of this object changes, the device will generate
the tacacsServiceAvailableChange notification."
REFERENCE
"tacacsServiceAvailableChange notification is defined in ruggedcomTrapsModule."
::= { rcDeviceError 11 }
rcDeviceErrSystem OBJECT-TYPE
SYNTAX BITS {
errCrashLog(0),
errWatchdogRst(1),
errBootupErr(2),
errCfgFailure(3),
errStackOvfl(4),
errHeapErr(5),
errRealTimeClk(6),
errRxBuffersLow(7),
errClockManager_OutOfResources(8),
errClockManager_PrimarySourceFailed(9),
errFpgaCompatibility(10),
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicated whether a device failure occured. Whenever the value of this object
changes, the device will generate the deviceErrTrap notification."
REFERENCE
"deviceErrTrap notification is defined in ruggedcomTrapsModule."
::= {rcDeviceError 12 }
-- ---------------------------------------------------------------------- --
-- Device Status information objects
-- ---------------------------------------------------------------------- --
rcDeviceStsCpuUsage OBJECT-TYPE
SYNTAX Integer32
UNITS "tenths of percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The percentage in tenths of percent of available CPU cycles used
for device operation as measured over the last second when
object was retreived."
::= { rcDeviceStatus 1 }
rcDeviceStsAvailableRam OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes of RAM still available in the system
control CPU."
::= { rcDeviceStatus 2 }
rcDeviceStsTemperature OBJECT-TYPE
SYNTAX Integer32
UNITS "Celsius degrees"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature measured in the device."
::= { rcDeviceStatus 3 }
rcDeviceStsPowerSupply1 OBJECT-TYPE
SYNTAX RcHardwareStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the status of Power Supply Module 1.
Whenever the value of this object changes from functional(2) to
notFunctional(3), or from notFunctionl(3) to functional(2),
the device will generate powerSupplyTrap notification."
REFERENCE
"powerSupplyTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceStatus 4 }
rcDeviceStsPowerSupply2 OBJECT-TYPE
SYNTAX RcHardwareStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the status of Power Supply Module 2.
Whenever the value of this object changes from functional(2) to
notFunctional(3), or from notFunctionl(3) to functional(2),
the device will generate powerSupplyTrap notification."
REFERENCE
"powerSupplyTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceStatus 5 }
rcDeviceStsCpuUsagePercent OBJECT-TYPE
SYNTAX Integer32
UNITS "percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The percentage of available CPU cycles used for device operation
as measured over the last second when object was retreived."
::= { rcDeviceStatus 6 }
rcDeviceStsFailSafeRelay OBJECT-TYPE
SYNTAX INTEGER {
energized(1),
deEnergized(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates status of fail safe relay in the device.
Fail safe relay is deEnergized(2) if there is at least one active
alarm recorded in the device."
::= { rcDeviceStatus 7 }
rcDeviceStsErrorAlarm OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates that at least one alarm of level ERROR, ALERT or CRITICAL
is active in the device."
::= { rcDeviceStatus 8 }
rcDeviceStsNoOfActiveAlarms OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of active alarms currently recorded in device."
::= { rcDeviceStatus 9 }
rcDeviceStsFanBank1 OBJECT-TYPE
SYNTAX RcFanStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the status of Fan Bank Module 1."
REFERENCE
"fanBankTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceStatus 10 }
rcDeviceStsFanBank2 OBJECT-TYPE
SYNTAX RcFanStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the status of Fan Bank Module 2."
REFERENCE
"fanBankTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceStatus 11 }
rcDeviceStsPwdsWeak OBJECT-TYPE
SYNTAX BITS {
adminPwd(0),
operPwd(1),
guestPwd(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if any of passwords is configured as 'weak'.
Change in the value of the bit in this object from '0' to '1'
will generate weakPasswordTrap."
REFERENCE
"weakPasswordTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceStatus 12 }
rcDeviceStsKeysDflt OBJECT-TYPE
SYNTAX BITS {
sshDfltKeys(0),
sslDfltKeys(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if any of secure services uses default keys and/or
certificates. Customer is advised to update keys for secure
services if defaults are used.
Change in the value of the bit in this object from '0' to '1'
will generate defaultKeysTrap notification."
REFERENCE
"defaultKeysTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceStatus 13 }
-- ---------------------------------------------------------------------- --
-- General System Information objects
-- ---------------------------------------------------------------------- --
rcDeviceInfoSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The manufacturing serial number of the device."
::= { rcDeviceInfo 1 }
rcDeviceInfoBootSwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version and the build date of the boot loader software."
::= { rcDeviceInfo 2 }
rcDeviceInfoMainSwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version and the build date of the main operating system
software."
::= { rcDeviceInfo 3 }
rcDeviceInfoMainBoardType OBJECT-TYPE
SYNTAX RcMainBoard
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The identification code of the device main board."
::= { rcDeviceInfo 4 }
rcDeviceInfoTotalRam OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes of RAM in the system control CPU."
::= { rcDeviceInfo 5 }
rcDeviceInfoPendingBootSwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version and the build date of the boot loader software
that has been loaded to the device and is pending reboot.
Whenever the value of this object changes from zero-length string
to any string of non-zero length, the device will generate
swUpgradeTrap notification."
REFERENCE
"swUpgradeTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceInfo 6 }
rcDeviceInfoPendingMainSwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version and the build date of the main operating system
software that has been loaded to the device and is pending reboot.
Whenever the value of this object changes from zero-length string
to any string of non-zero length, the device will generate
swUpgradeTrap notification."
REFERENCE
"swUpgradeTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceInfo 7 }
rcDeviceInfoCfgRevision OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The configuration file revision.
The revision number will be updated whenever file is saved to the
flash memory. This number is recorded in config.csv at the time file
is uploaded from the device.
Whenever the value of this object changes the device will generate
cfgChangeTrap notification."
REFERENCE
"cfgChangeTrap notification is defined in ruggedcomTrapsModule."
::= { rcDeviceInfo 8 }
rcDeviceInfoMinBootSwVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum version of the boot loader software required by
ROS device. If this version is not newer than the version
retreived as a value of object rcDeviceInfoBootSwVersion, trap
bootVersionMismatchTrap will be generated."
REFERENCE
"bootVersionMismatchTrap notification is defined in
ruggedcomTrapsModule."
::= { rcDeviceInfo 9 }
-- ---------------------------------------------------------------------- --
-- Device control commands objects
-- ---------------------------------------------------------------------- --
rcDeviceCommReset OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the value of this object to 'true(1)' will cause device
to reboot.
As a result of Read request the agent will return value 'false(2)'."
::= { rcDeviceCommands 1}
rcDeviceCommLoadDefaultCfg OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the value of this object to 'true(1)' will force device
to load default configuration to all tables.
As a result of Read request the agent will return value 'false(2)'."
::= { rcDeviceCommands 2}
rcDeviceCommClearAlarms OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the value of this object to 'true(1)' will cause device
to clear all alarms.
As a result of Read request the agent will return value 'false(2)'."
::= { rcDeviceCommands 3}
rcDeviceCommClearSyslog OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the value of this object to 'true(1)' will cause device
to clear syslog.txt file.
As a result of Read request the agent will return value 'false(2)'."
::= { rcDeviceCommands 4}
rcDeviceCommClearLogs OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the value of this object to 'true(1)' will cause device
to clear syslog.txt and crashlog.txt files.
As a result of Read request the agent will return value 'false(2)'."
::= { rcDeviceCommands 5}
rcDeviceCommIdentify OBJECT-TYPE
SYNTAX Integer32 (0..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time Period in seconds for which the device should continue flashing
the LEDs when possible so that device is visually recognized.
Setting this value to any value greater than 0 will start LED flash
timer on the device.Setting the value to 0 will stop the LED flash
timer. On Read request agent always sends back the existing Timeout
value for LED flash Timer."
::= { rcDeviceCommands 6 }
-- ---------------------------------------------------------------------- --
-- Object Groups
-- ---------------------------------------------------------------------- --
rcSysErrObjectsGroup OBJECT-GROUP
OBJECTS {
rcDeviceErrBootupError,
rcDeviceErrWatchdogReset,
rcDeviceErrConfigurationFailure,
rcDeviceErrCrashLogCreated,
rcDeviceErrStackOverflow,
rcDeviceErrHeapError,
rcDeviceErrDateAndTimeSetFailed,
rcDeviceErrNtpServerUnreachable,
rcDeviceErrBootPTftpTrFailed,
rcDeviceErrRadiusServerUnreachable,
rcDeviceErrTacacsServerUnreachable
}
STATUS obsolete
DESCRIPTION
"A group of objects providing information about irregularities
in the device."
::= { rcSysInfoGroups 1 }
rcSysStsObjectsGroup OBJECT-GROUP
OBJECTS {
rcDeviceStsCpuUsage,
rcDeviceStsCpuUsagePercent,
rcDeviceStsAvailableRam
}
STATUS obsolete
DESCRIPTION
"A group of objects providing information device resources."
::= { rcSysInfoGroups 2 }
rcSysStsObjectsTemperatureGroup OBJECT-GROUP
OBJECTS {
rcDeviceStsTemperature
}
STATUS current
DESCRIPTION
"This group is created to allow MIBs for products that do not have
temperature sensore installed to exclude rcDeviceStsTemperature
object."
::= { rcSysInfoGroups 3 }
rcSysStsPowerSupplyGroup OBJECT-GROUP
OBJECTS {
rcDeviceStsPowerSupply1,
rcDeviceStsPowerSupply2
}
STATUS current
DESCRIPTION
"A group of objects providing information about power supply modules
in the device. This group is mandatory for products with redundant
power supply."
::= { rcSysInfoGroups 4 }
rcSysInfoDeviceInfoGroup OBJECT-GROUP
OBJECTS {
rcDeviceInfoMainBoardType,
rcDeviceInfoTotalRam,
rcDeviceInfoBootSwVersion,
rcDeviceInfoMainSwVersion,
rcDeviceInfoPendingBootSwVersion,
rcDeviceInfoPendingMainSwVersion,
rcDeviceInfoCfgRevision,
rcDeviceInfoSerialNumber
}
STATUS current
DESCRIPTION
"A group of object providing manufacturer's information about
product's main board hardware, software, identification."
::= { rcSysInfoGroups 5 }
rcSysDeviceCommGroup OBJECT-GROUP
OBJECTS {
rcDeviceCommReset,
rcDeviceCommLoadDefaultCfg,
rcDeviceCommClearAlarms,
rcDeviceCommClearSyslog,
rcDeviceCommClearLogs
}
STATUS current
DESCRIPTION
"A group of object providing device control commands."
::= { rcSysInfoGroups 6 }
rcSysDeviceCommIdentifyGroup OBJECT-GROUP
OBJECTS {
rcDeviceCommIdentify
}
STATUS current
DESCRIPTION
"A group of object providing device control commands for
visual recognisation of the device (LED flashing)."
::= { rcSysInfoGroups 7 }
rcSysStsObjectsGroup1 OBJECT-GROUP
OBJECTS {
rcDeviceStsCpuUsage,
rcDeviceStsCpuUsagePercent,
rcDeviceStsAvailableRam,
rcDeviceStsErrorAlarm,
rcDeviceStsFailSafeRelay,
rcDeviceStsNoOfActiveAlarms
}
STATUS current
DESCRIPTION
"A group of objects providing information about device resources."
::= { rcSysInfoGroups 8 }
rcSysStsFanBankGroup OBJECT-GROUP
OBJECTS {
rcDeviceStsFanBank1,
rcDeviceStsFanBank2
}
STATUS current
DESCRIPTION
"A group of objects providing information about fan bank modules
in the device. This group is mandatory for products with redundant
fan banks."
::= { rcSysInfoGroups 9 }
rcSysDeviceSecurityGroup OBJECT-GROUP
OBJECTS {
rcDeviceStsPwdsWeak
}
STATUS current
DESCRIPTION
"A group of object providing device control commands."
::= { rcSysInfoGroups 10 }
rcSysDeviceSecurityGroup01 OBJECT-GROUP
OBJECTS {
rcDeviceStsPwdsWeak,
rcDeviceStsKeysDflt,
rcDeviceInfoMinBootSwVer
}
STATUS current
DESCRIPTION
"A group of object providing device control commands."
::= { rcSysInfoGroups 11 }
rcSysErrObjectsGroup1 OBJECT-GROUP
OBJECTS {
rcDeviceErrSystem
}
STATUS current
DESCRIPTION
"A group of objects providing information about device system errors."
::= { rcSysInfoGroups 12 }
END