SAF-INTEGRAX-MIB DEFINITIONS ::= BEGIN
-- Definitions for include by other SAF Tehnika mib modules
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32, Counter64,
TimeTicks
FROM SNMPv2-SMI -- [RFC2578]
pointToPoint
FROM SAF-ENTERPRISE
DateAndTime, TEXTUAL-CONVENTION
FROM SNMPv2-TC
DisplayString, PhysAddress
FROM RFC1213-MIB
safIntegra
FROM SAF-INTEGRA-MIB
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF -- [RFC2580]
IpAddress
FROM SNMPv2-SMI -- [RFC2578]
IANAifType
FROM IANAifType-MIB;
-- saf OBJECT IDENTIFIER ::= { enterprises 7571 }
-- microwaveRadio OBJECT IDENTIFIER ::= { tehnika 1 }
-- pointToPoint OBJECT IDENTIFIER ::= { microwaveRadio 1 }
-- safIntegra OBJECT IDENTIFIER ::= { pointToPoint 7 }
integraX MODULE-IDENTITY
LAST-UPDATED "202006260000Z" -- 26 jun 2020
ORGANIZATION "SAF Tehnika"
CONTACT-INFO
"SAF Tehnika technical support
<techsupport@saftehnika.com>"
DESCRIPTION
"SAF Integra-X device management base"
-- Revision history
REVISION "202006260000Z" -- 26 jun 2020
DESCRIPTION
"Added system services / firmware upgrade."
REVISION "202005190000Z" -- 19 may 2020
DESCRIPTION
"Added system services / reboot option."
REVISION "202005080000Z" -- 08 may 2020
DESCRIPTION
"ACM min/max modem modulation read-only support."
REVISION "202001140000Z" -- 14 jan 2020
DESCRIPTION
"Added LSP/Backup port status."
REVISION "201911270000Z" -- 27 nov 2019
DESCRIPTION
"Added system service sensors."
REVISION "201906110000Z" -- 11 jun 2019
DESCRIPTION
"Added device fan error status."
REVISION "201904230000Z" -- 23 apr 2019
DESCRIPTION
"Added device type, serial number and product code."
REVISION "201903070000Z" -- 07 mar 2019
DESCRIPTION
"Changed integraXifPortSpeed to integraXifPortHighSpeed, that will use Mbps instead of bps.
Added modem performance counters separately to modem A and modem B."
REVISION "201903060000Z" -- 06 mar 2019
DESCRIPTION
"Added modem A and B specific performance counters"
REVISION "201902170000Z" -- 17 feb 2019
DESCRIPTION
"Public Release 1.0"
::= { safIntegra 10 }
FixedDiv20 ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-2"
STATUS current
DESCRIPTION "Fixed point, two decimals"
SYNTAX Integer32
FixedDiv10 ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-1"
STATUS current
DESCRIPTION "Fixed point, two decimals"
SYNTAX Integer32
integraXtimestamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Last data update time"
::= { integraX 1 }
integraXradio OBJECT IDENTIFIER ::= { integraX 2 }
--radio/radioA
integraXradioA OBJECT IDENTIFIER ::= { integraXradio 1 }
integraXradioAtxPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Output power of radio transmitter"
::= { integraXradioA 1 }
integraXradioAtxFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Frequency of radio transmitter"
::= { integraXradioA 2 }
integraXradioArxLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Level of the received signal"
::= { integraXradioA 3 }
integraXradioArxLevelState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
low(2),
high(3),
error(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Received signal level state"
::= { integraXradioA 4 }
integraXradioAside OBJECT-TYPE
SYNTAX INTEGER {
high(1),
low(2),
error(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Radio side: Low/High"
::= { integraXradioA 5 }
integraXradioAtxMute OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2),
error(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of 'Tx mute'
1 - Tx is muted,
2 - Tx is not muted.
3 - Status information unavailable"
::= { integraXradioA 6 }
integraXradioAtxMuteDuration OBJECT-TYPE
SYNTAX Integer32(0..214748364)
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time remaning for Tx to be muted in seconds.
To turn mute on send number of seconds between 10 and MAX.
To turn mute off send 0.
GET will retrieve remaining duration for mute or
0 if Tx mute is turned off."
::= { integraXradioA 7 }
integraXradioAduplexShift OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Utilized duplex shift in kHz"
::= { integraXradioA 8 }
integraXradioArxFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Frequency of radio receiver"
::= { integraXradioA 9 }
integraXradioAtemperature OBJECT-TYPE
SYNTAX FixedDiv10
UNITS "C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Radio module temperature"
::= { integraXradioA 10 }
integraXradioApll OBJECT-TYPE
SYNTAX INTEGER {
error(1),
ok(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "PLL state of local-oscillator generator"
::= { integraXradioA 11 }
--Settable radio parameter range values
integraXradioArangesTable OBJECT-TYPE
SYNTAX SEQUENCE OF IntegraXradioArangeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Network interface port status data."
::= { integraXradioA 12 }
integraXradioArangeEntry OBJECT-TYPE
SYNTAX IntegraXradioArangeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing network physical port status info."
INDEX { integraXradioArangeEntryIndex }
::= { integraXradioArangesTable 1 }
IntegraXradioArangeEntry ::=
SEQUENCE {
integraXradioArangeEntryIndex
Integer32,
integraXradioArangeDescr
DisplayString,
integraXradioArangeTxPower
Integer32,
integraXradioArangeTxFrequency
Integer32
}
integraXradioArangeEntryIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each range
entry. Starts with 1 and is equal to a number of all range
parameters."
::= { integraXradioArangeEntry 1 }
integraXradioArangeDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"'Minimal' and 'maximal' labels"
::= { integraXradioArangeEntry 2 }
integraXradioArangeTxPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Output power ranges for radio transmitter"
::= { integraXradioArangeEntry 3 }
integraXradioArangeTxFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Frequency ranges for radio transmitter"
::= { integraXradioArangeEntry 4 }
--radio/radioB
integraXradioB OBJECT IDENTIFIER ::= { integraXradio 2 }
integraXradioBtxPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Output power of radio transmitter"
::= { integraXradioB 1 }
integraXradioBtxFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Frequency of radio transmitter"
::= { integraXradioB 2 }
integraXradioBrxLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Level of the received signal"
::= { integraXradioB 3 }
integraXradioBrxLevelState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
low(2),
high(3),
error(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Received signal level state"
::= { integraXradioB 4 }
integraXradioBside OBJECT-TYPE
SYNTAX INTEGER {
high(1),
low(2),
error(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Radio side: Low/High"
::= { integraXradioB 5 }
integraXradioBtxMute OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2),
error(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of 'Tx mute'
1 - Tx is muted,
2 - Tx is not muted.
3 - Status information unavailable"
::= { integraXradioB 6 }
integraXradioBtxMuteDuration OBJECT-TYPE
SYNTAX Integer32(0..214748364)
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time remaning for Tx to be muted in seconds.
To turn mute on send number of seconds between 10 and MAX.
To turn mute off send 0.
GET will retrieve remaining duration for mute or
0 if Tx mute is turned off."
::= { integraXradioB 7 }
integraXradioBduplexShift OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Utilized duplex shift in kHz"
::= { integraXradioB 8 }
integraXradioBrxFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Frequency of radio receiver"
::= { integraXradioB 9 }
integraXradioBtemperature OBJECT-TYPE
SYNTAX FixedDiv10
UNITS "C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Radio module temperature"
::= { integraXradioB 10 }
integraXradioBpll OBJECT-TYPE
SYNTAX INTEGER {
error(1),
ok(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "PLL state of local-oscillator generator"
::= { integraXradioB 11 }
--Settable radio parameter range values
integraXradioBrangesTable OBJECT-TYPE
SYNTAX SEQUENCE OF IntegraXradioBrangeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Network interface port status data."
::= { integraXradioB 12 }
integraXradioBrangeEntry OBJECT-TYPE
SYNTAX IntegraXradioBrangeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing network physical port status info."
INDEX { integraXradioBrangeEntryIndex }
::= { integraXradioBrangesTable 1 }
IntegraXradioBrangeEntry ::=
SEQUENCE {
integraXradioBrangeEntryIndex
Integer32,
integraXradioBrangeDescr
DisplayString,
integraXradioBrangeTxPower
Integer32,
integraXradioBrangeTxFrequency
Integer32
}
integraXradioBrangeEntryIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each range
entry. Starts with 1 and is equal to a number of all range
parameters."
::= { integraXradioBrangeEntry 1 }
integraXradioBrangeDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"'Minimal' and 'maximal' labels"
::= { integraXradioBrangeEntry 2 }
integraXradioBrangeTxPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Output power ranges for radio transmitter"
::= { integraXradioBrangeEntry 3 }
integraXradioBrangeTxFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Frequency ranges for radio transmitter"
::= { integraXradioBrangeEntry 4 }
integraXmodem OBJECT IDENTIFIER ::= { integraX 3 }
--modem/modemA
integraXmodemA OBJECT IDENTIFIER ::= { integraXmodem 1 }
integraXmodemAacquireStatus OBJECT-TYPE
SYNTAX INTEGER {
acquireInProgress(1),
acquireLocked(2),
acquireFailed(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the current status of modem data acquire
when queried modem status.
For detailed info use modemAcquireLastStatusDetails."
::= { integraXmodemA 1 }
integraXmodemAnormalizedMse OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current normalized MSE value (floating point value multiplied by 10)"
::= { integraXmodemA 2 }
-- ldpcDecoderStress OBJECT-TYPE
integraXmodemAfecLoad OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Decoder stress or FEC load value (floating point in textual representation)"
::= { integraXmodemA 3 }
--TODO: change to new parameter related to FEC load
integraXmodemAxpdEst OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "XPD Estimated value (floating point value multiplied by 10)"
::= { integraXmodemA 4 }
integraXmodemAacquireLastStatusDetails OBJECT-TYPE
SYNTAX INTEGER {
acquireLocked(1),
acquireSweep(4),
acquireMSEerror(5),
acquireBITerror(6),
acquireStopped(12),
acquireSMerror(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the last status of successfull or unsuccessful modem data acquire"
::= { integraXmodemA 5 }
integraXmodemAtemperature OBJECT-TYPE
SYNTAX FixedDiv10
UNITS "C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem DSP temperature"
::= { integraXmodemA 6 }
integraXmodemArxModulation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current (actual) Rx Modulation"
::= { integraXmodemA 7 }
integraXmodemAtxModulation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current (actual) Tx Modulation"
::= { integraXmodemA 8 }
integraXmodemArxCapacity OBJECT-TYPE
SYNTAX Integer32
UNITS "kb/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Rx ethernet capacity in kilobits per second"
::= { integraXmodemA 9 }
integraXmodemAtxCapacity OBJECT-TYPE
SYNTAX Integer32
UNITS "kb/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Tx ethernet capacity in kilobits per second"
::= { integraXmodemA 10 }
integraXmodemAacmEngine OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
error(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "ACM engine status"
::= { integraXmodemA 11 }
integraXmodemAcarrierOffset OBJECT-TYPE
SYNTAX Integer32
UNITS "Hz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem carrier offset"
::= { integraXmodemA 12 }
--modem A performance counters
integraXmodemAcountTime OBJECT-TYPE
SYNTAX Counter64
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance count time"
::= { integraXmodemA 13 }
integraXmodemAerroredBlock OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance errored blocks"
::= { integraXmodemA 14 }
integraXmodemAerroredSecond OBJECT-TYPE
SYNTAX Counter64
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance errored seconds"
::= { integraXmodemA 15 }
integraXmodemAseverelyErroredSecond OBJECT-TYPE
SYNTAX Counter64
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance severely errored seconds"
::= { integraXmodemA 16 }
integraXmodemAbackgroundBlockError OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance background block errors"
::= { integraXmodemA 17 }
integraXmodemAtotalBlockNumber OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance total block number"
::= { integraXmodemA 18 }
integraXmodemAerroredSecondRatio OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance errored second ratio"
::= { integraXmodemA 19 }
integraXmodemAseverelyErroredSecondRatio OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance severely errored second ratio"
::= { integraXmodemA 20 }
integraXmodemAbackgroundBlockErrorRatio OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance background block error ratio"
::= { integraXmodemA 21 }
integraXmodemAuptime OBJECT-TYPE
SYNTAX Counter64
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance : uptime"
::= { integraXmodemA 22 }
integraXmodemAunavailtime OBJECT-TYPE
SYNTAX Counter64
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance : unavailtime"
::= { integraXmodemA 23 }
integraXmodemAfecLdpcBlockCounter OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem FEC load block counter"
::= { integraXmodemA 24 }
integraXmodemAfecLdpcUncorrectedBlockCounter OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem FEC load uncorrected block counter"
::= { integraXmodemA 25 }
integraXmodemAfecLdpcUncorrectedPercent OBJECT-TYPE
SYNTAX Integer32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem FEC load uncorrected percent"
::= { integraXmodemA 26 }
integraXmodemAfecRsBlockCounter OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem FEC load RS block counter"
::= { integraXmodemA 27 }
integraXmodemAfecRsUncorrectedBlockCounter OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem FEC load RS uncorrected block counter"
::= { integraXmodemA 28 }
integraXmodemAmodulationACMmin OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Minimal modulation for ACM enabled profile"
::= { integraXmodemA 29 }
integraXmodemAmodulationACMmax OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Maximal modulation for ACM enabled profile"
::= { integraXmodemA 30 }
--modem/modemB
integraXmodemB OBJECT IDENTIFIER ::= { integraXmodem 2 }
integraXmodemBacquireStatus OBJECT-TYPE
SYNTAX INTEGER {
acquireInProgress(1),
acquireLocked(2),
acquireFailed(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the current status of modem data acquire
when queried modem status.
For detailed info use modemAcquireLastStatusDetails."
::= { integraXmodemB 1 }
integraXmodemBnormalizedMse OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current normalized MSE value (floating point value multiplied by 10)"
::= { integraXmodemB 2 }
-- ldpcDecoderStress OBJECT-TYPE
integraXmodemBfecLoad OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Decoder stress or FEC load value (floating point in textual representation)"
::= { integraXmodemB 3 }
integraXmodemBxpdEst OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "XPD Estimated value (floating point value multiplied by 10)"
::= { integraXmodemB 4 }
integraXmodemBacquireLastStatusDetails OBJECT-TYPE
SYNTAX INTEGER {
acquireLocked(1),
acquireSweep(4),
acquireMSEerror(5),
acquireBITerror(6),
acquireStopped(12),
acquireSMerror(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the last status of successfull or unsuccessful modem data acquire"
::= { integraXmodemB 5 }
integraXmodemBtemperature OBJECT-TYPE
SYNTAX FixedDiv10
UNITS "C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem DSP temperature"
::= { integraXmodemB 6 }
integraXmodemBrxModulation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current (actual) Rx Modulation"
::= { integraXmodemB 7 }
integraXmodemBtxModulation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current (actual) Tx Modulation"
::= { integraXmodemB 8 }
integraXmodemBrxCapacity OBJECT-TYPE
SYNTAX Integer32
UNITS "kb/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Rx ethernet capacity in kilobits per second"
::= { integraXmodemB 9 }
integraXmodemBtxCapacity OBJECT-TYPE
SYNTAX Integer32
UNITS "kb/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Tx ethernet capacity in kilobits per second"
::= { integraXmodemB 10 }
integraXmodemBacmEngine OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
error(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "ACM engine status"
::= { integraXmodemB 11 }
integraXmodemBcarrierOffset OBJECT-TYPE
SYNTAX Integer32
UNITS "Hz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem carrier offset"
::= { integraXmodemB 12 }
--modem B performance counters
integraXmodemBcountTime OBJECT-TYPE
SYNTAX Counter64
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance count time"
::= { integraXmodemB 13 }
integraXmodemBerroredBlock OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance errored blocks"
::= { integraXmodemB 14 }
integraXmodemBerroredSecond OBJECT-TYPE
SYNTAX Counter64
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance errored seconds"
::= { integraXmodemB 15 }
integraXmodemBseverelyErroredSecond OBJECT-TYPE
SYNTAX Counter64
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance severely errored seconds"
::= { integraXmodemB 16 }
integraXmodemBbackgroundBlockError OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance background block errors"
::= { integraXmodemB 17 }
integraXmodemBtotalBlockNumber OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance total block number"
::= { integraXmodemB 18 }
integraXmodemBerroredSecondRatio OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance errored second ratio"
::= { integraXmodemB 19 }
integraXmodemBseverelyErroredSecondRatio OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance severely errored second ratio"
::= { integraXmodemB 20 }
integraXmodemBbackgroundBlockErrorRatio OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance background block error ratio"
::= { integraXmodemB 21 }
integraXmodemBuptime OBJECT-TYPE
SYNTAX Counter64
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance : uptime"
::= { integraXmodemB 22 }
integraXmodemBunavailtime OBJECT-TYPE
SYNTAX Counter64
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem performance : unavailtime"
::= { integraXmodemB 23 }
integraXmodemBfecLdpcBlockCounter OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem FEC load block counter"
::= { integraXmodemB 24 }
integraXmodemBfecLdpcUncorrectedBlockCounter OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem FEC load uncorrected block counter"
::= { integraXmodemB 25 }
integraXmodemBfecLdpcUncorrectedPercent OBJECT-TYPE
SYNTAX Integer32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem FEC load uncorrected percent"
::= { integraXmodemB 26 }
integraXmodemBfecRsBlockCounter OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem FEC load RS block counter"
::= { integraXmodemB 27 }
integraXmodemBfecRsUncorrectedBlockCounter OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem FEC load RS uncorrected block counter"
::= { integraXmodemB 28 }
integraXmodemBmodulationACMmin OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Minimal modulation for ACM enabled profile"
::= { integraXmodemB 29 }
integraXmodemBmodulationACMmax OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Maximal modulation for ACM enabled profile"
::= { integraXmodemB 30 }
--modem common
integraXmodemBandwidth OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Signal bandwidth"
::= { integraXmodem 3 }
integraXmodemModulation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modulation (preferred)"
::= { integraXmodem 4 }
integraXsystem OBJECT IDENTIFIER ::= { integraX 4 }
integraXsysCPUtemperature OBJECT-TYPE
SYNTAX FixedDiv10
UNITS "C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "System CPU temperature"
::= { integraXsystem 2 }
integraXsysLicenseExpire OBJECT-TYPE
SYNTAX Gauge32
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "License expires after number of seconds.
In the case of -1, check licenseGenStatus status"
::= { integraXsystem 3 }
integraXsysLicenseGenStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
expired(2),
unknown(3),
unlimitedTime(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "License General status."
::= { integraXsystem 4 }
integraXsysPSUvoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "mV"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Power voltage in mV"
::= { integraXsystem 5 }
integraXsysPSUcurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Power current in mA"
::= { integraXsystem 6 }
integraXsysPSUpower OBJECT-TYPE
SYNTAX Integer32
UNITS "mW"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Power consumption in mW"
::= { integraXsystem 7 }
integraXsysBoardTemperature OBJECT-TYPE
SYNTAX FixedDiv10
UNITS "C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "System temperature"
::= { integraXsystem 8 }
integraXsysFreeMemory OBJECT-TYPE
SYNTAX FixedDiv10
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "System free memory"
::= { integraXsystem 9 }
integraXsysCPUidle OBJECT-TYPE
SYNTAX FixedDiv10
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "System CPU idle"
::= { integraXsystem 10 }
integraXsysDeviceType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device type name"
::= { integraXsystem 11 }
integraXsysDeviceSerial OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device serial number"
::= { integraXsystem 12 }
integraXsysDeviceProductModel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device product model code"
::= { integraXsystem 13 }
integraXsysFanError OBJECT-TYPE
SYNTAX BITS {
no(0),
fan1(1),
fan2(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device fan 1 and fan 2 error status"
::= { integraXsystem 14 }
-- service sensors
integraXsysSw1v0core OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SW_1V0_CORE"
::= { integraXsystem 15 }
integraXsysSw1v0avdd OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SW_1V0_AVDD"
::= { integraXsystem 16 }
integraXsysSw1v2a OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SW_1V2A"
::= { integraXsystem 17 }
integraXsysSw1v5ddr OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SW_1V5_DDR"
::= { integraXsystem 18 }
integraXsysSw1v8 OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SW_1V8"
::= { integraXsystem 19 }
integraXsysSw2v5 OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SW_2V5"
::= { integraXsystem 20 }
integraXsysSw3v3 OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SW_3V3"
::= { integraXsystem 21 }
integraXsysVttrefPs OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "VTTVREF_PS"
::= { integraXsystem 22 }
integraXsysVttddrPs OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "VTTDDR_PS"
::= { integraXsystem 23 }
integraXsysZq1v0 OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "ZQ_1V0"
::= { integraXsystem 24 }
integraXsysZq1v5 OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "ZQ_1V5"
::= { integraXsystem 25 }
integraXsysZq1v8 OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "ZQ_1V8"
::= { integraXsystem 26 }
integraXsysZq2v5 OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "ZQ_2V5"
::= { integraXsystem 27 }
integraXsysZq3v3 OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "ZQ_3V3"
::= { integraXsystem 28 }
integraXsys5v0d OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "5V0D"
::= { integraXsystem 29 }
integraXsysSw1v2 OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SW_1V2"
::= { integraXsystem 30 }
integraXsysMdmVddcAvs OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "MDM_VDDC_AVS"
::= { integraXsystem 31 }
integraXsysMdm3v3 OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "MDM_3V3"
::= { integraXsystem 32 }
integraXsysMdm1v0aPm OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "MDM_1V0A_PM"
::= { integraXsystem 33 }
integraXsysMdm1v0a OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "MDM_1V0A"
::= { integraXsystem 34 }
integraXsysMdm1v8a OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "MDM_1V8A"
::= { integraXsystem 35 }
integraXsysMdmDAC02v5a OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "MDM_DAC0_2V5A"
::= { integraXsystem 36 }
integraXsysMdmDAC12v5 OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "MDM_DAC1_2V5A"
::= { integraXsystem 37 }
integraXsysMdmDAC22v5 OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "MDM_DAC2_2V5A"
::= { integraXsystem 38 }
integraXsysMdm1v8io OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "MDM_1V8_IO"
::= { integraXsystem 39 }
integraXsysMdm3v3io OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "MDM_3V3_IO"
::= { integraXsystem 40 }
integraXsys3v3Radio OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "3V3_RADIO"
::= { integraXsystem 41 }
integraXsysMdm4v0 OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "MDM_4V0"
::= { integraXsystem 42 }
integraXsys5v0nRadio OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "5V0N_RADIO"
::= { integraXsystem 43 }
integraXsysCoreVddSns OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "CORE_VDD_SNS"
::= { integraXsystem 44 }
integraXsys40v0RadioSns OBJECT-TYPE
SYNTAX FixedDiv20
UNITS "V"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "40V0_RADIO_SNS"
::= { integraXsystem 45 }
integraXsysServices OBJECT IDENTIFIER ::= { integraXsystem 46 }
integraXsysServicesReboot OBJECT-TYPE
SYNTAX INTEGER {
reboot(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object can only be set to 1.
It initiates system reboot immediately."
::= { integraXsysServices 1 }
integraXsysServicesFtpSwitch OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2),
unknown(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Status and on/off switch for the FTP server"
::= { integraXsysServices 2 }
integraXsysServicesFwCurrInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Currently running FW info.
Same output as in RFC1213-MIB::sysDescr."
::= { integraXsysServices 3 }
integraXsysServicesFwAvailView OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "List FW available for installation (uploaded)."
::= { integraXsysServices 4 }
integraXsysServicesFwRemove OBJECT-TYPE
SYNTAX INTEGER {
candfw1(1),
candfw2(2),
candfw3(3),
candfw4(4),
candfw5(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Remove available (uploaded) FW version.
View FW versions in integraXsysServicesFwAvailView.
Send number corresponding to info in integraXsysServicesFwAvailView."
::= { integraXsysServices 5 }
integraXsysServicesFwRemoveAll OBJECT-TYPE
SYNTAX INTEGER {
removeAllCandfw(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Remove all available (uploaded) FW versions."
::= { integraXsysServices 6 }
integraXsysServicesFwUpload OBJECT-TYPE
SYNTAX INTEGER {
upload(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Upload FW (make available for installation).
You need to upload a firmware to FTP ftp://anonymous@DEVICE_IP:/firmware/ first!
You must have only 1 firmware in firmware folder for this option to work!
This option only starts upload on the device and doesn't return success status for it.
Usually you should wait some time while the device completes upload.
SNMP won't response to quieries while upload is in progress.
You may check integraXsysServicesFwAvailView to see if your FW is ready for install."
::= { integraXsysServices 7 }
integraXsysServicesFwInst OBJECT-TYPE
SYNTAX INTEGER {
candfw1(1),
candfw2(2),
candfw3(3),
candfw4(4),
candfw5(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Install FW version.
You need check integraXsysServicesFwAvailView to see FW versions ready for install.
This option only starts installation on the device and doesn't return success status for it.
Usually you should wait some time while the device completes installation.
SNMP won't response to quieries while upload is in progress.
If FW installation was successful, integraXsysServicesFwSwitchNext will show
different FW bank value for the next boot."
::= { integraXsysServices 8 }
integraXsysServicesFwSwitchRunning OBJECT-TYPE
SYNTAX INTEGER {
fw1(1),
fw2(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "FW running bank info.
Use integraXsysServicesFwSwitchNext to view and switch FW bank for the next boot."
::= { integraXsysServices 9 }
integraXsysServicesFwSwitchNext OBJECT-TYPE
SYNTAX INTEGER {
fw1(1),
fw2(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "FW next boot bank info. Set request can change FW bank for the next boot.
View running FW bank number in integraXsysServicesFwSwitchRunning."
::= { integraXsysServices 10 }
-- Ethernet
integraXethernet OBJECT IDENTIFIER ::= { integraX 5 }
-- Port status
integraXifStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF IntegraXifPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Network interface port status data."
::= { integraXethernet 1 }
integraXifPortEntry OBJECT-TYPE
SYNTAX IntegraXifPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing network physical port status info."
INDEX { integraXifPortStatIndex }
::= { integraXifStatusTable 1 }
IntegraXifPortEntry ::=
SEQUENCE {
integraXifPortStatIndex
Integer32,
integraXifPortStatDescr
DisplayString,
integraXifPortType
IANAifType,
integraXifPortMtu
Integer32,
integraXifPortHighSpeed
Gauge32,
integraXifPortPhysAddress
PhysAddress,
integraXifPortAdminStatus
INTEGER,
integraXifPortOperStatus
INTEGER,
integraXifPortLastChange
TimeTicks,
integraXifPortAutoneg
INTEGER,
integraXifPortDuplex
INTEGER,
integraXifPortSyncEthActive
INTEGER,
integraXifPortSyncEthPrio
Integer32,
integraXifPortFlowControl
INTEGER
}
integraXifPortStatIndex OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each physical
network interface. It is recommended that
values are assigned contiguously starting from 1."
::= { integraXifPortEntry 1 }
integraXifPortStatDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical network interface description.
LAN1 is electrical, LAN2 and LAN3 are SFP
and WAN is radio port."
::= { integraXifPortEntry 2 }
integraXifPortType OBJECT-TYPE
SYNTAX IANAifType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of interface, distinguished according to
the physical/link protocol(s) immediately `below'
the network layer in the protocol stack."
::= { integraXifPortEntry 3 }
integraXifPortMtu OBJECT-TYPE
SYNTAX Integer32
UNITS "B"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum transmission unit value in bytes."
::= { integraXifPortEntry 4 }
integraXifPortHighSpeed OBJECT-TYPE
SYNTAX Gauge32
UNITS "Mbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link speed in 1 000 000 * bits per second."
::= { integraXifPortEntry 5 }
integraXifPortPhysAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface's address at the protocol layer
immediately `below' the network layer in the
protocol stack. For interfaces which do not have
such an address (e.g., a serial line), this object
should contain an octet string of zero length."
::= { integraXifPortEntry 6 }
integraXifPortAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Desired state of network interfaces. Interfaces
can be enabled(1), disabled(2), unknown(3) (no info received)."
::= { integraXifPortEntry 7 }
integraXifPortOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual state of interfaces. Link can be up(1),
down(2) or in unknown(3) state."
::= { integraXifPortEntry 8 }
integraXifPortLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter value is always 0 at the moment."
::= { integraXifPortEntry 9 }
integraXifPortAutoneg OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Auto-negotiation status. Unknown means no info was received."
::= { integraXifPortEntry 10 }
integraXifPortDuplex OBJECT-TYPE
SYNTAX INTEGER {
full(1),
half(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Duplex status for the interface."
::= { integraXifPortEntry 11 }
integraXifPortSyncEthActive OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Synchronous Ethernet status.
Can be active(1) or inactive(0)."
::= { integraXifPortEntry 12 }
integraXifPortSyncEthPrio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Synchronous Ethernet priority."
::= { integraXifPortEntry 13 }
integraXifPortFlowControl OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Flow control status."
::= { integraXifPortEntry 14 }
-- Port statistics
integraXifStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF IntegraXifPortStcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Network interface port statistics data."
::= { integraXethernet 2 }
integraXifPortStcEntry OBJECT-TYPE
SYNTAX IntegraXifPortStcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing network physical port statistics counter data."
INDEX { integraXifPortStcIndex }
::= { integraXifStatisticsTable 1 }
IntegraXifPortStcEntry ::=
SEQUENCE {
integraXifPortStcIndex
Integer32,
integraXifPortStcDescr
DisplayString,
integraXifTimePassed
TimeTicks,
integraXifIngressPackets
Counter64,
integraXifIngressBytes
Counter64,
integraXifEgressPackets
Counter64,
integraXifEgressBytes
Counter64,
integraXifEtherStatsMulticastPkts
Counter64,
integraXifEtherStatsBroadcastPkts
Counter64,
integraXifEtherStatsPkts64Octets
Counter64,
integraXifEtherStatsPkts65to127Octets
Counter64,
integraXifEtherStatsPkts128to255Octets
Counter64,
integraXifEtherStatsPkts256to511Octets
Counter64,
integraXifEtherStatsPkts512to1023Octets
Counter64,
integraXifEtherStatsPkts1024to1518Octets
Counter64,
integraXifEtherStatsOversizePkts
Counter64,
integraXifEtherRxOversizePkts
Counter64,
integraXifEtherTxOversizePkts
Counter64,
integraXifEtherStatsOctets
Counter64,
integraXifEtherStatsPkts
Counter64,
integraXifEtherStatsTXNoErrors
Counter64,
integraXifEtherStatsRXNoErrors
Counter64,
integraXifEtherStatsPkts1519to1522Octets
Counter64,
integraXifIfInOctets
Counter64,
integraXifIfOutOctets
Counter64,
integraXifDot1dTpPortInFrames
Counter64,
integraXifDot1dTpPortOutFrames
Counter64,
integraXifReceivedPkts64Octets
Counter64,
integraXifTransmittedPkts64Octets
Counter64,
integraXifReceivedPkts65to127Octets
Counter64,
integraXifTransmittedPkts65to127Octets
Counter64,
integraXifReceivedPkts128to255Octets
Counter64,
integraXifTransmittedPkts128to255Octets
Counter64,
integraXifReceivedPkts256to511Octets
Counter64,
integraXifTransmittedPkts256to511Octets
Counter64,
integraXifReceivedPkts512to1023Octets
Counter64,
integraXifTransmittedPkts512to1023Octets
Counter64,
integraXifReceivedPkts1024to1518Octets
Counter64,
integraXifTransmittedPkts1024to1518Octets
Counter64,
integraXifIfInBroadcastPkts
Counter64,
integraXifIfOutBroadcastPkts
Counter64,
integraXifIfInMulticastPkts
Counter64,
integraXifIfOutMulticastPkts
Counter64,
integraXifDot3InPauseFrames
Counter64,
integraXifDot3OutPauseFrames
Counter64,
integraXifEtherStatsUndersizePkts
Counter64,
integraXifEtherStatsFragments
Counter64,
integraXifEtherStatsCRCAlignErrors
Counter64,
integraXifEtherStatsJabbers
Counter64,
integraXifIngressBPS
Integer32,
integraXifIngressPPS
Integer32,
integraXifEgressBPS
Integer32,
integraXifEgressPPS
Integer32,
integraXifAllCoSQoutPackets
Counter64,
integraXifAllCoSQoutBytes
Counter64,
integraXifAllCoSQdroppedPackets
Counter64,
integraXifAllCoSQdroppedBytes
Counter64,
integraXifProcessedRxPackets
Counter64,
integraXifProcessedRxBytes
Counter64
}
integraXifPortStcIndex OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each physical
network interface. It is recommended that
values are assigned contiguously starting from 1."
::= { integraXifPortStcEntry 1 }
integraXifPortStcDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical network interface description.
LAN1 is electrical, LAN2 and LAN3 are SFP,
WAN is radio port and MNG is internal management interface."
::= { integraXifPortStcEntry 2 }
integraXifTimePassed OBJECT-TYPE
SYNTAX TimeTicks
UNITS "s/100"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Statistics collection time."
::= { integraXifPortStcEntry 3 }
integraXifIngressPackets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packets that ingress on the port."
::= { integraXifPortStcEntry 4 }
integraXifIngressBytes OBJECT-TYPE
SYNTAX Counter64
UNITS "B"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes that ingress on the port."
::= { integraXifPortStcEntry 5 }
integraXifEgressPackets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packets that egress on the port."
::= { integraXifPortStcEntry 6 }
integraXifEgressBytes OBJECT-TYPE
SYNTAX Counter64
UNITS "B"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bytes that egress on the port."
::= { integraXifPortStcEntry 7 }
integraXifEtherStatsMulticastPkts OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of good packets (both received and
transmitted) that were directed to a multicast address.
Note that this number does not include packets directed
to the broadcast address."
::= { integraXifPortStcEntry 8 }
integraXifEtherStatsBroadcastPkts OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of good packets (both received and
transmitted) that were directed to the broadcast address.
Note that this does not include multicast packets."
::= { integraXifPortStcEntry 9 }
integraXifEtherStatsPkts64Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) (both received and transmitted)
that were 64 octets in length
(excluding framing bits but including FCS octets)."
::= { integraXifPortStcEntry 10 }
integraXifEtherStatsPkts65to127Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) (both received and transmitted)
that were between 65 and 127 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { integraXifPortStcEntry 11 }
integraXifEtherStatsPkts128to255Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) (both received and transmitted) that were
between 128 and 255 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { integraXifPortStcEntry 12 }
integraXifEtherStatsPkts256to511Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) (both received and transmitted) that were
between 256 and 511 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { integraXifPortStcEntry 13 }
integraXifEtherStatsPkts512to1023Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) (both received and transmitted) that were
between 512 and 1023 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { integraXifPortStcEntry 14 }
integraXifEtherStatsPkts1024to1518Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) (both received and transmitted) that were
between 1024 and 1518 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { integraXifPortStcEntry 15 }
integraXifEtherStatsOversizePkts OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets (both received and
transmitted) that were longer than 1518
octets (excluding framing bits but including
FCS octets) but were otherwise well formed."
::= { integraXifPortStcEntry 16 }
integraXifEtherRxOversizePkts OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets received
that were longer than 1518 octets
(excluding framing bits but including
FCS octets) but were otherwise well formed."
::= { integraXifPortStcEntry 17 }
integraXifEtherTxOversizePkts OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets transmitted
that were longer than 1518 octets
(excluding framing bits but including
FCS octets) but were otherwise well formed."
::= { integraXifPortStcEntry 18 }
integraXifEtherStatsOctets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of octets of data (including
those in bad packets) both received and
transmitted."
::= { integraXifPortStcEntry 19 }
integraXifEtherStatsPkts OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets (including bad packets)
both received and transmitted."
::= { integraXifPortStcEntry 20 }
integraXifEtherStatsTXNoErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets that were transmitted
without errors."
::= { integraXifPortStcEntry 21 }
integraXifEtherStatsRXNoErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of packets that were received
without errors."
::= { integraXifPortStcEntry 22 }
integraXifEtherStatsPkts1519to1522Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) (both received and transmitted) that were
between 1519 and 1522 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { integraXifPortStcEntry 23 }
integraXifIfInOctets OBJECT-TYPE
SYNTAX Counter64
UNITS "octet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of octets of data (including
those in bad packets) that were received."
::= { integraXifPortStcEntry 24 }
integraXifIfOutOctets OBJECT-TYPE
SYNTAX Counter64
UNITS "octet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of octets of data (including
those in bad packets) that were transmitted."
::= { integraXifPortStcEntry 25 }
integraXifDot1dTpPortInFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames that have been received by
this port from its segment."
::= { integraXifPortStcEntry 26 }
integraXifDot1dTpPortOutFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames that have been transmitted by
this port to its segment."
::= { integraXifPortStcEntry 27 }
integraXifReceivedPkts64Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of received packets that were
64 octets in length (excluding framing bits
but including FCS octets)."
::= { integraXifPortStcEntry 28 }
integraXifTransmittedPkts64Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of transmitted packets that were
64 octets in length (excluding framing bits
but including FCS octets)."
::= { integraXifPortStcEntry 29 }
integraXifReceivedPkts65to127Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of received packets that were
between 65 and 127 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { integraXifPortStcEntry 30 }
integraXifTransmittedPkts65to127Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of transmitted packets that were
between 65 and 127 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { integraXifPortStcEntry 31 }
integraXifReceivedPkts128to255Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of received packets that were
between 128 and 255 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { integraXifPortStcEntry 32 }
integraXifTransmittedPkts128to255Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of transmitted packets that were
between 128 and 255 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { integraXifPortStcEntry 33 }
integraXifReceivedPkts256to511Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of received packets that were
between 256 and 511 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { integraXifPortStcEntry 34 }
integraXifTransmittedPkts256to511Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of transmitted packets that were
between 256 and 511 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { integraXifPortStcEntry 35 }
integraXifReceivedPkts512to1023Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of received packets that were
between 512 and 1023 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { integraXifPortStcEntry 36 }
integraXifTransmittedPkts512to1023Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of transmitted packets that were
between 512 and 1023 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { integraXifPortStcEntry 37 }
integraXifReceivedPkts1024to1518Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of received packets that were
between 1024 and 1518 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { integraXifPortStcEntry 38 }
integraXifTransmittedPkts1024to1518Octets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of transmitted packets that were
between 1024 and 1518 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { integraXifPortStcEntry 39 }
integraXifIfInBroadcastPkts OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of received good packets
that were directed to the broadcast address.
Note that this does not include multicast packets."
::= { integraXifPortStcEntry 40 }
integraXifIfOutBroadcastPkts OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of transmitted good packets
that were directed to the broadcast address.
Note that this does not include multicast packets."
::= { integraXifPortStcEntry 41 }
integraXifIfInMulticastPkts OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of received good packets
that were directed to a multicast address.
Note that this number does not include broadcast packets."
::= { integraXifPortStcEntry 42 }
integraXifIfOutMulticastPkts OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of transmitted good packets
that were directed to a multicast address.
Note that this number does not include broadcast packets."
::= { integraXifPortStcEntry 43 }
integraXifDot3InPauseFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of MAC Control frames received on this
interface with an opcode indicating the PAUSE
operation.
This counter does not increment when the
interface is operating in half-duplex mode."
::= { integraXifPortStcEntry 44 }
integraXifDot3OutPauseFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of MAC Control frames transmitted on
this interface with an opcode indicating the
PAUSE operation.
This counter does not increment when the
interface is operating in half-duplex mode."
::= { integraXifPortStcEntry 45 }
integraXifEtherStatsUndersizePkts OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
less than 64 octets long (excluding framing bits,
but including FCS octets) and were otherwise well
formed."
::= { integraXifPortStcEntry 46 }
integraXifEtherStatsFragments OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were less than
64 octets in length (excluding framing bits but including
FCS octets) and had either a bad Frame Check Sequence
(FCS) with an integral number of octets (FCS Error) or a
bad FCS with a non-integral number of octets (Alignment
Error).
Note that it is entirely normal for etherStatsFragments to
increment. This is because it counts both runts (which are
normal occurrences due to collisions) and noise hits."
::= { integraXifPortStcEntry 47 }
integraXifEtherStatsCRCAlignErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that
had a length (excluding framing bits, but
including FCS octets) of between 64 and 1518
octets, inclusive, but had either a bad
Frame Check Sequence (FCS) with an integral
number of octets (FCS Error) or a bad FCS with
a non-integral number of octets (Alignment Error)."
::= { integraXifPortStcEntry 48 }
integraXifEtherStatsJabbers OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
longer than 1518 octets (excluding framing bits,
but including FCS octets), and had either a bad
Frame Check Sequence (FCS) with an integral number
of octets (FCS Error) or a bad FCS with a non-integral
number of octets (Alignment Error).
Note that this definition of jabber is different
than the definition in IEEE-802.3 section 8.2.1.5
(10BASE5) and section 10.3.1.4 (10BASE2). These
documents define jabber as the condition where any
packet exceeds 20 ms. The allowed range to detect
jabber is between 20 ms and 150 ms."
::= { integraXifPortStcEntry 49 }
integraXifIngressBPS OBJECT-TYPE
SYNTAX Integer32
UNITS "Bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ingoing data transfer rate in bytes per second."
::= { integraXifPortStcEntry 50 }
integraXifIngressPPS OBJECT-TYPE
SYNTAX Integer32
UNITS "pps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ingoing data transfer rate in packets per second."
::= { integraXifPortStcEntry 51 }
integraXifEgressBPS OBJECT-TYPE
SYNTAX Integer32
UNITS "Bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Outgoing data transfer rate in bytes per second."
::= { integraXifPortStcEntry 52 }
integraXifEgressPPS OBJECT-TYPE
SYNTAX Integer32
UNITS "pps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Outgoing data transfer rate in packets per second."
::= { integraXifPortStcEntry 53 }
integraXifAllCoSQoutPackets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"All CoSQ outgoing packets."
::= { integraXifPortStcEntry 54 }
integraXifAllCoSQoutBytes OBJECT-TYPE
SYNTAX Counter64
UNITS "B"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"All CoSQ outgoing bytes."
::= { integraXifPortStcEntry 55 }
integraXifAllCoSQdroppedPackets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"All CoSQ dropped packets."
::= { integraXifPortStcEntry 56 }
integraXifAllCoSQdroppedBytes OBJECT-TYPE
SYNTAX Counter64
UNITS "B"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"All CoSQ dropped bytes."
::= { integraXifPortStcEntry 57 }
integraXifProcessedRxPackets OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Processed received packets."
::= { integraXifPortStcEntry 58 }
integraXifProcessedRxBytes OBJECT-TYPE
SYNTAX Counter64
UNITS "B"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Processed received bytes."
::= { integraXifPortStcEntry 59 }
integraXifLspPortAdminState OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
lsp(2),
backup(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LSP port status."
::= { integraXethernet 3 }
integraXifLspPortList OBJECT-TYPE
SYNTAX BITS {
none(0),
lan1(1),
lan2(2),
lan3(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LSP port status."
::= { integraXethernet 4 }
integraXifLspPortStatus OBJECT-TYPE
SYNTAX INTEGER {
lspPortOK(1),
lspPortDownBlockedByLSP(2),
backupNoLink(3),
backupLinkActive(4),
backupLinkReady(5),
unknown(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LSP port status."
::= { integraXethernet 5 }
-- Configuration applying/saving objects
integraXexecuteConfig OBJECT-TYPE
SYNTAX INTEGER {
execute(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object can only be set to 1.
It initiates new running configuration
applying using values, that have been set before.
Setting it when no new changes are available
will do nothing and return an error.
GET will return 0 if there were no errors,
while executing configuration or will return
a bitmask, that shows which SET requests have failed.
Those failed requests will be shown bit wise
from LSB as follows:
BIT0 radioTxMuteDuration
BIT1 radioTxFrequency
BIT2 radioTxPower"
::= { integraX 6 }
integraXneedStore OBJECT-TYPE
SYNTAX INTEGER {
no(0)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object shows if there is unsaved,
but executed (running) configuration.
Unsaved changes will be lost after
device reboot. Unsaved entities are shown
bit wise, starting from LSB as follows:
BIT0 Aggregation
BIT1 Event log
BIT2 Modem
BIT3 Network
BIT4 Performance
BIT5 Radio
BIT6 SNMP
BIT7 Synchronous Ethernet
BIT8 System"
::= { integraX 7 }
integraXstoreConfig OBJECT-TYPE
SYNTAX INTEGER {
store(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object can only be set to 1.
It initiates saving of running configuration.
It will only work if there are unsaved,
but executed (running) changes (configuration).
Setting it when no new running configuration
is available will do nothing and return an error."
::= { integraX 8 }
-- IP settings
integraXnetCfg OBJECT IDENTIFIER ::= { integraX 9 }
integraXnetCfgIPaddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Local IP address"
::= { integraXnetCfg 1 }
integraXnetCfgIPmask OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Local IP mask"
::= { integraXnetCfg 2 }
integraXnetCfgIPgateway OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "IP gateway
Send '0' or '255.255.255.255' to clear."
::= { integraXnetCfg 3 }
integraXnetCfgRemoteIPaddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Remote IP address"
::= { integraXnetCfg 4 }
-- Conformance
integraXConformance OBJECT IDENTIFIER ::= { integraX 10 }
integraXCompliances OBJECT IDENTIFIER ::= { integraXConformance 1 }
integraXCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "The compliance statement for SNMP engine which
implements the SAF Tehnika Integra-X device."
MODULE -- this module
MANDATORY-GROUPS {
integraXMiscGroup,
integraXRadioGroup,
integraXModemGroup,
integraXSystemGroup,
integraXEthernetGeneralGroup,
integraXEthernetMiiPortGroup }
::= { integraXCompliances 1 }
integraXGroups OBJECT IDENTIFIER ::= { integraXConformance 2 }
integraXMiscGroup OBJECT-GROUP
OBJECTS {
integraXtimestamp
}
STATUS current
DESCRIPTION "misc data"
::= { integraXGroups 1 }
integraXRadioGroup OBJECT-GROUP
OBJECTS {
integraXradioAtxPower,
integraXradioAtxFrequency,
integraXradioArxLevel,
integraXradioArxLevelState,
integraXradioAside,
integraXradioAtxMute,
integraXradioAtxMuteDuration,
integraXradioAduplexShift,
integraXradioArxFrequency,
integraXradioAtemperature,
integraXradioApll,
integraXradioArangeEntryIndex,
integraXradioArangeDescr,
integraXradioArangeTxPower,
integraXradioArangeTxFrequency,
integraXradioBtxPower,
integraXradioBtxFrequency,
integraXradioBrxLevel,
integraXradioBrxLevelState,
integraXradioBside,
integraXradioBtxMute,
integraXradioBtxMuteDuration,
integraXradioBduplexShift,
integraXradioBrxFrequency,
integraXradioBtemperature,
integraXradioBpll,
integraXradioBrangeEntryIndex,
integraXradioBrangeDescr,
integraXradioBrangeTxPower,
integraXradioBrangeTxFrequency
}
STATUS current
DESCRIPTION "Radio group."
::= { integraXGroups 2 }
integraXModemGroup OBJECT-GROUP
OBJECTS {
integraXmodemAacquireStatus,
integraXmodemAnormalizedMse,
integraXmodemAfecLoad,
integraXmodemAxpdEst,
integraXmodemAacquireLastStatusDetails,
integraXmodemAtemperature,
integraXmodemArxModulation,
integraXmodemAtxModulation,
integraXmodemArxCapacity,
integraXmodemAtxCapacity,
integraXmodemAacmEngine,
integraXmodemAcarrierOffset,
integraXmodemAcountTime,
integraXmodemAerroredBlock,
integraXmodemAerroredSecond,
integraXmodemAseverelyErroredSecond,
integraXmodemAbackgroundBlockError,
integraXmodemAtotalBlockNumber,
integraXmodemAerroredSecondRatio,
integraXmodemAseverelyErroredSecondRatio,
integraXmodemAbackgroundBlockErrorRatio,
integraXmodemAuptime,
integraXmodemAunavailtime,
integraXmodemAfecLdpcBlockCounter,
integraXmodemAfecLdpcUncorrectedBlockCounter,
integraXmodemAfecLdpcUncorrectedPercent,
integraXmodemAfecRsBlockCounter,
integraXmodemAfecRsUncorrectedBlockCounter,
integraXmodemBacquireStatus,
integraXmodemBnormalizedMse,
integraXmodemBfecLoad,
integraXmodemBxpdEst,
integraXmodemBacquireLastStatusDetails,
integraXmodemBtemperature,
integraXmodemBrxModulation,
integraXmodemBtxModulation,
integraXmodemBrxCapacity,
integraXmodemBtxCapacity,
integraXmodemBacmEngine,
integraXmodemBcarrierOffset,
integraXmodemBcountTime,
integraXmodemBerroredBlock,
integraXmodemBerroredSecond,
integraXmodemBseverelyErroredSecond,
integraXmodemBbackgroundBlockError,
integraXmodemBtotalBlockNumber,
integraXmodemBerroredSecondRatio,
integraXmodemBseverelyErroredSecondRatio,
integraXmodemBbackgroundBlockErrorRatio,
integraXmodemBuptime,
integraXmodemBunavailtime,
integraXmodemBfecLdpcBlockCounter,
integraXmodemBfecLdpcUncorrectedBlockCounter,
integraXmodemBfecLdpcUncorrectedPercent,
integraXmodemBfecRsBlockCounter,
integraXmodemBfecRsUncorrectedBlockCounter,
integraXmodemBandwidth,
integraXmodemModulation,
integraXmodemAmodulationACMmin,
integraXmodemAmodulationACMmax,
integraXmodemBmodulationACMmin,
integraXmodemBmodulationACMmax
}
STATUS current
DESCRIPTION "Modem group."
::= { integraXGroups 3 }
integraXSystemGroup OBJECT-GROUP
OBJECTS {
integraXsysCPUtemperature,
integraXsysLicenseExpire,
integraXsysLicenseGenStatus,
integraXsysPSUvoltage,
integraXsysPSUcurrent,
integraXsysPSUpower,
integraXsysBoardTemperature,
integraXsysFreeMemory,
integraXsysCPUidle,
integraXsysDeviceType,
integraXsysDeviceSerial,
integraXsysDeviceProductModel,
integraXsysFanError,
integraXexecuteConfig,
integraXneedStore,
integraXstoreConfig,
integraXsysSw1v0core,
integraXsysSw1v0avdd,
integraXsysSw1v2a,
integraXsysSw1v5ddr,
integraXsysSw1v8,
integraXsysSw2v5,
integraXsysSw3v3,
integraXsysVttrefPs,
integraXsysVttddrPs,
integraXsysZq1v0,
integraXsysZq1v5,
integraXsysZq1v8,
integraXsysZq2v5,
integraXsysZq3v3,
integraXsys5v0d,
integraXsysSw1v2,
integraXsysMdmVddcAvs,
integraXsysMdm3v3,
integraXsysMdm1v0aPm,
integraXsysMdm1v0a,
integraXsysMdm1v8a,
integraXsysMdmDAC02v5a,
integraXsysMdmDAC12v5,
integraXsysMdmDAC22v5,
integraXsysMdm1v8io,
integraXsysMdm3v3io,
integraXsys3v3Radio,
integraXsysMdm4v0,
integraXsys5v0nRadio,
integraXsysCoreVddSns,
integraXsys40v0RadioSns,
integraXsysServicesReboot,
integraXsysServicesFtpSwitch,
integraXsysServicesFwCurrInfo,
integraXsysServicesFwAvailView,
integraXsysServicesFwRemove,
integraXsysServicesFwRemoveAll,
integraXsysServicesFwUpload,
integraXsysServicesFwInst,
integraXsysServicesFwSwitchRunning,
integraXsysServicesFwSwitchNext
}
STATUS current
DESCRIPTION "System group."
::= { integraXGroups 4 }
integraXEthernetGeneralGroup OBJECT-GROUP
OBJECTS {
integraXifPortStatIndex,
integraXifPortStatDescr,
integraXifPortType,
integraXifPortMtu,
integraXifPortHighSpeed,
integraXifPortPhysAddress,
integraXifPortAdminStatus,
integraXifPortOperStatus,
integraXifPortLastChange,
integraXifPortAutoneg,
integraXifPortDuplex,
integraXifPortSyncEthActive,
integraXifPortSyncEthPrio,
integraXifPortFlowControl,
integraXifPortStcIndex,
integraXifPortStcDescr,
integraXifTimePassed,
integraXifIngressPackets,
integraXifIngressBytes,
integraXifEgressPackets,
integraXifEgressBytes,
integraXifEtherRxOversizePkts,
integraXifEtherTxOversizePkts,
integraXifReceivedPkts64Octets,
integraXifTransmittedPkts64Octets,
integraXifReceivedPkts65to127Octets,
integraXifTransmittedPkts65to127Octets,
integraXifReceivedPkts128to255Octets,
integraXifTransmittedPkts128to255Octets,
integraXifReceivedPkts256to511Octets,
integraXifTransmittedPkts256to511Octets,
integraXifReceivedPkts512to1023Octets,
integraXifTransmittedPkts512to1023Octets,
integraXifReceivedPkts1024to1518Octets,
integraXifTransmittedPkts1024to1518Octets,
integraXifIfInBroadcastPkts,
integraXifIfOutBroadcastPkts,
integraXifIfInMulticastPkts,
integraXifIfOutMulticastPkts,
integraXifIngressBPS,
integraXifIngressPPS,
integraXifEgressBPS,
integraXifEgressPPS,
integraXifAllCoSQoutPackets,
integraXifAllCoSQoutBytes,
integraXifAllCoSQdroppedPackets,
integraXifAllCoSQdroppedBytes,
integraXifProcessedRxPackets,
integraXifProcessedRxBytes,
integraXnetCfgIPaddress,
integraXnetCfgIPmask,
integraXnetCfgIPgateway,
integraXnetCfgRemoteIPaddress,
integraXifLspPortAdminState,
integraXifLspPortList,
integraXifLspPortStatus
}
STATUS current
DESCRIPTION "A collection to objects, providing info applicable to
all network interfaces."
::= { integraXGroups 5 }
integraXEthernetMiiPortGroup OBJECT-GROUP
OBJECTS {
integraXifEtherStatsMulticastPkts,
integraXifEtherStatsBroadcastPkts,
integraXifEtherStatsPkts64Octets,
integraXifEtherStatsPkts65to127Octets,
integraXifEtherStatsPkts128to255Octets,
integraXifEtherStatsPkts256to511Octets,
integraXifEtherStatsPkts512to1023Octets,
integraXifEtherStatsPkts1024to1518Octets,
integraXifEtherStatsOversizePkts,
integraXifEtherStatsOctets,
integraXifEtherStatsPkts,
integraXifEtherStatsTXNoErrors,
integraXifEtherStatsRXNoErrors,
integraXifEtherStatsPkts1519to1522Octets,
integraXifIfInOctets,
integraXifIfOutOctets,
integraXifDot1dTpPortInFrames,
integraXifDot1dTpPortOutFrames,
integraXifDot3InPauseFrames,
integraXifDot3OutPauseFrames,
integraXifEtherStatsUndersizePkts,
integraXifEtherStatsFragments,
integraXifEtherStatsCRCAlignErrors,
integraXifEtherStatsJabbers
}
STATUS current
DESCRIPTION "A collection of objects, providing info applicable
only to MII group interfaces."
::= { integraXGroups 6 }
END