mibs/MIBS/sagemcom/PERFORMANCE-MIB
2023-12-05 12:25:34 +01:00

541 lines
16 KiB
Plaintext

--*******************************************************************
--* SAGEM, IONOS *
--*******************************************************************
--*******************************************************************
--
-- Filename: perf
--
-- File type: .mib
--
--
-- Description: SNMP source Mib file.
--
-- Describes performance records.
--
--
-- Version: 19 11 2002
--
-- Date(DD MM YYYY): 15 11 02 last update for IONOS NMS
--
-- Contact: D. Mobuchon, F. Bonnevialle
--
-- History:
-- Version: Date: 25 10 1999
-- Version: MIB-P0-301199 Date: 30 11 1999
--
-- Name: F.Bonnevialle
-- Date: 15 11 2002
-- Desc: Modification for SilverCreek Compiler
--*******************************************************************
--*******************************************************************
--* Copyright (c) 2002, SAGEM , All rights reserved. *
--*******************************************************************
--*******************************************************************
-- MIB: PERFORMANCE-MIB
--*******************************************************************
PERFORMANCE-MIB DEFINITIONS ::= BEGIN
--*******************************************************************
-- IMPORTS
--*******************************************************************
IMPORTS
sagemDr FROM SAGEM-DR-MIB
IntDateTime FROM EQUIPMENT-MIB
MODULE-IDENTITY,OBJECT-TYPE,Gauge32,
NOTIFICATION-TYPE FROM SNMPv2-SMI
TimeTicks FROM RFC1155-SMI
DisplayString FROM SNMPv2-TC ;
-- TRAP-TYPE FROM RFC-1215;
performance MODULE-IDENTITY
LAST-UPDATED "0211150000Z"
ORGANIZATION "SAGEM/DR Tolbiac Centre"
CONTACT-INFO
" "
DESCRIPTION
"
Modification:
Date: 15 11 2002
Description:
sagemDr replace sagem-dr
NOTIFICATION-TYPE replace TRAP-TYPE
Modification:
Date: 20 12 1999
Description: modification of comments
Modification:
Date: 25 11 1999
Name: thresholdUas,thresholdSes,thresholdEs,thresholdBbe
Description: read-write instead of read-only
Modification:
Date: 19 11 1999
Name:
Description: modification of comments
Creation:
Date: 25 10 1999
Description:
The MIB module describes performance records.
It also describes the traps that could be sent
either to notify a threshold or a non null quality
record, for the devices that support that feature.
"
::= { sagemDr 102 }
--*******************************************************************
NearFar ::= INTEGER { near (1), far(2) }
perfClear OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When a set command is issued on this variable, this clears a
part of the performance record depending on the value of the oid:
performance : all the performance records
cptTable : all the counter table
uasTable : all the unavailable periods table
oid : the counter and uas records of this object
An equipment may implement only a subset of these commands."
::= { performance 1 }
--*******************************************************************
-- Performance over the ports
-- This table contains the history of the quality counters
-- When a Date is used as index the index value is MAXDate-Date
-- to keep a lexicographic order.
cptNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of used records (rows) in 'cptTable'."
::= { performance 2 }
cptTable OBJECT-TYPE
SYNTAX SEQUENCE OF CptEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of cpt in equipment."
::= { performance 3 }
cptEntry OBJECT-TYPE
SYNTAX CptEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular cpt of the equipment."
INDEX { cptObject, cptNearFar, cptDuration, cptDate }
::= { cptTable 1 }
CptEntry ::= SEQUENCE {
cptObject OBJECT IDENTIFIER,
cptName DisplayString,
cptNearFar NearFar,
cptDuration TimeTicks,
cptDate IntDateTime,
cptUAS Gauge32,
cptSES Gauge32,
cptES Gauge32,
cptBBE Gauge32
}
cptObject OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to the function/interface from which this reccord
was taken"
::= { cptEntry 1 }
cptName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A text string which identifies the object localisation. For the
structure of this string, see 'logName' in the log MIB "
::= { cptEntry 2 }
cptNearFar OBJECT-TYPE
SYNTAX NearFar
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates near or far performance record"
::= { cptEntry 3 }
cptDuration OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The full duration of measurement for the record.
This table contains either logged entries and current ones.
For curent performance counters, it is not the actual mesured
duration, but the duration from start to normal end.
The standard durations are 15 minutes and 24 hours; the value
can be coded in TimeTicks or in minute (see the variable
'perfDurationUnit')"
::= { cptEntry 4 }
cptDate OBJECT-TYPE
SYNTAX IntDateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When the record had started."
::= { cptEntry 5 }
cptUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of UnAvailable Seconds mesured."
::= { cptEntry 6 }
cptSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Severely Errored Seconds mesured."
::= { cptEntry 7 }
cptES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Errored Seconds mesured."
::= { cptEntry 8 }
cptBBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Background Errors Blocks mesured."
::= { cptEntry 9 }
--*******************************************************************
-- Unavailable periods (uap)
-- This table contains the unavailable period records logged
--by the system
uapNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of unavailable period records stored in the 'uapTable'."
::= { performance 4 }
uapTable OBJECT-TYPE
SYNTAX SEQUENCE OF UapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of unavailable period records in equipment."
::= { performance 5 }
uapEntry OBJECT-TYPE
SYNTAX UapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular unavailable period of the equipment."
INDEX { uapObject, uapNearFar, uapBegin }
::= { uapTable 1 }
UapEntry ::=
SEQUENCE {
uapObject OBJECT IDENTIFIER,
uapName DisplayString,
uapNearFar NearFar,
uapBegin IntDateTime,
uapEnd IntDateTime
}
uapObject OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to the function/interface from witch this reccord
was taken."
::= { uapEntry 1 }
uapName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A text string which identifies the object localisation. For the
structure of this string, see 'logName' in the log MIB "
::= { uapEntry 2 }
uapNearFar OBJECT-TYPE
SYNTAX NearFar
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates near or far performance record"
::= { uapEntry 3 }
uapBegin OBJECT-TYPE
SYNTAX IntDateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When the unavailable period has started."
::= { uapEntry 4 }
uapEnd OBJECT-TYPE
SYNTAX IntDateTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When the unavailable period has finished."
::= { uapEntry 5 }
--*******************************************************************
-- Threshold values for performance threshold configuration
-- A record on this table contains the confuguration the threshold
-- for a interface or a interface type
-- This table must be initialized by the equipment during its restart
-- The write access authorization of this table is optional
thresholdNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of threshold in equipment."
::= { performance 6 }
thresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF ThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of threshold in equipment."
::= { performance 7 }
thresholdEntry OBJECT-TYPE
SYNTAX ThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular threshold of the equipment."
INDEX { thresholdObject, thresholdNearFar,
thresholdDuration, thresholdType }
::= { thresholdTable 1 }
ThresholdEntry ::= SEQUENCE {
thresholdObject OBJECT IDENTIFIER,
thresholdName DisplayString,
thresholdNearFar NearFar,
thresholdDuration TimeTicks,
thresholdType INTEGER,
thresholdUas INTEGER,
thresholdSes INTEGER,
thresholdEs INTEGER,
thresholdBbe INTEGER
}
thresholdObject OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to the interface or the interface type to which
these parameters apply."
::= { thresholdEntry 1 }
thresholdName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A text string which identifies the interface localisation.
For the structure of this string, see 'logName' in the
log MIB "
::= { thresholdEntry 2 }
thresholdNearFar OBJECT-TYPE
SYNTAX NearFar
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates near or far performance threshold.
Equipment may or may not implement far threshold."
::= { thresholdEntry 3 }
thresholdDuration OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The normal duration of the counter with which the threshold
is associed.
The standard durations are 15 minutes and 24 hours;
"
::= { thresholdEntry 4 }
thresholdType OBJECT-TYPE
SYNTAX INTEGER { raise(1), clear(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When set to `raise' the event threshold exceded is generated
when one of the corresponding counter cross its theshold.
When set to `clear', the event threshold exceded is cleared
when there is no counters above of its corresponding threshold.
The `clear'thresholds are optionnal(the standard value is zero)
"
::= { thresholdEntry 5 }
thresholdUas OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of unavailable seconds within a counting
period above which a performance event is issued
for the interface/function"
::= { thresholdEntry 6 }
thresholdSes OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of severely errored seconds within a
counting period above which a performance event
is issued for the interface/function"
::= { thresholdEntry 7 }
thresholdEs OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of errored seconds within a counting
period above which a performance event is issued
for the interface/function"
::= { thresholdEntry 8 }
thresholdBbe OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of background block errors within a
counting period above which a performance event is
issued for the interface/function"
::= { thresholdEntry 9 }
-- ***************************************************************
-- perfDurationUnit OBJECT-TYPE
-- SYNTAX INTEGER {timeTicks (1), minutes (2)}
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Unit of the performance duration used in this MIB."
-- ::= { performance 8 }
--
-- ***************************************************************
-- Performance enable variables
--
-- The performance enables port by port are not in this MIB
-- The equipment can implement them in its proprietary MIB the
-- performance .
-- Also the transmission quality status port by port are not
-- in this MIb
-- The equipment must implement them in its proprietary MIB
-- the performance
-- performanceEnable OBJECT-TYPE
-- SYNTAX SagemBoolean
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "
-- It is a global enable of the performance in the equipment
-- The default value of this variable is 'false'
-- "
-- ::= { performance 9 }
-- perfTrapEnable OBJECT-TYPE
-- SYNTAX SagemBoolean
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "
-- It is a global enable of the performance trap sending
-- The default value of this variable is 'true'
-- "
-- ::= { performance 10 }
-- perfThresholdTrapEnable OBJECT-TYPE
-- SYNTAX SagemBoolean
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "
-- It is a global enable of the performance threshold overflow
-- trap sending
-- The default value of this variable is 'true'
-- "
-- ::= { performance 11 }
-- ***************************************************************
-- qualityTrap TRAP-TYPE
-- ENTERPRISE performance
-- VARIABLES { cptObject, cptName, cptNearFar,
-- cptDuration, cptDate, cptUAS,
-- cptSES, cptES, cptBBE }
-- DESCRIPTION
-- " This trap allows the equipment to notify its quality records "
-- ::= 2
perfTraps OBJECT IDENTIFIER ::= { performance 0 }
qualityTrap NOTIFICATION-TYPE
OBJECTS { cptObject, cptName, cptNearFar,
cptDuration, cptDate, cptUAS,
cptSES, cptES, cptBBE }
STATUS current
DESCRIPTION "This trap allows the equipment to notify its quality records"
REFERENCE ""
::= { perfTraps 2 }
END