mibs/MIBS/sagemcom/PROTECTION-MIB
2023-12-05 12:25:34 +01:00

1273 lines
39 KiB
Plaintext

--*******************************************************************
--* SAGEM SA *
--*******************************************************************
--*******************************************************************
-- Filename: protection
-- File type: .mib
--
-- Description: SNMPc source Mib file.
--
-- Version: 19 11 2002
--
-- Date(DD MM YYYY): 15 11 02 last update for IONOS NMS
--
-- Contact: D. Mobuchon, F. Bonnevialle
--
-- History:
--
-- Name: F.Bonnevialle
-- Date: 12 12 2000
-- Desc: original
--
-- Name: F.Bonnevialle/S.Laurent
-- Date: 04 05 2001
-- Desc: Modification to fit with SDH-ETS MIB
--
-- Name: F.Bonnevialle/S.Laurent
-- Date: 05 06 2001
-- Desc: Bug correction
--
-- Name: J.Thieser
-- Date: 10 08 01
-- Desc: modifications for IONOS NMS (SPRing)
--
-- Name: F.Bonnevialle
-- Date: 15 11 2002
-- Desc: Modification for SilverCreek Compiler
--
--*******************************************************************
--*******************************************************************
--* Copyright (c) 2002, SAGEM , All rights reserved. *
--*******************************************************************
--*******************************************************************
-- MIB: PROTECTION-MIB
--*******************************************************************
PROTECTION-MIB DEFINITIONS ::= BEGIN
--*******************************************************************
-- IMPORTS
--*******************************************************************
IMPORTS
sagemDr FROM SAGEM-DR-MIB
SagemBoolean, Severity FROM EQUIPMENT-MIB
MODULE-IDENTITY,OBJECT-TYPE FROM SNMPv2-SMI;
protection MODULE-IDENTITY
LAST-UPDATED "9911290000Z"
ORGANIZATION "SAGEM-Tolbiac drd/ddp/tmhd"
CONTACT-INFO
" "
DESCRIPTION
" This MIB describe protection mechanisms used by SDH equipment"
::= { sagemDr 130 }
-- multiplex section protection
msp OBJECT IDENTIFIER ::= { protection 10 }
-- multiplex section shared protection ring
msSPRing OBJECT IDENTIFIER ::= { protection 20 }
-- sub network connection protection
sncp OBJECT IDENTIFIER ::= { protection 30 }
-- card protection
cardp OBJECT IDENTIFIER ::= { protection 40 }
--*******************************************************************
--* Common declarations
--*******************************************************************
TrafficStatus ::= INTEGER
{
none(0), -- Future case of a non-implemented link
working(1),
protection(2)
}
--*******************************************************************
--* multiplex section protection (msp)
--*******************************************************************
MspInitiator ::= INTEGER
{
unknown(0),
local(1),
remote(2)
}
MspFailure ::= INTEGER
{
none(0),pam(1),scm(2),otm(4),scmOtm(6)
}
MspPriority ::= INTEGER
{
unknown(0),
highG783(1),
low(2)
}
MspStatus ::= INTEGER
{
lockoutProtection(15),forcedSwitch(14),
highSF(13),lowSF(12),highSD(11),lowSD(10),
manualSwitch(8),waitToRestore(6),exercise(4),
reverseRequest(2),doNotRevert(1),noRequest(0)
}
MspType ::= INTEGER
{
unknown(0),
onePlusOneOptimized(1),
onePlusOneCompatible(2),
oneForN(3)
}
MspDirection ::= INTEGER
{
unknown(0),
unidirectionnal(1),
bidirectionnal(2)
}
MspCommand ::= INTEGER
{
clear(0),lw(1),lp(2),fsW(3),fsP(4),msW(5),msP(6),exer(7)
}
mspNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of multiplex section protection in equipment."
::= { msp 1 }
mspTable OBJECT-TYPE
SYNTAX SEQUENCE OF MspEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of multiplex section protection in equipment."
::= { msp 2 }
mspEntry OBJECT-TYPE
SYNTAX MspEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular multiplex section protection of the equipment.
Each entry is created in using the msTTPTable of the Sdh-Ets MIB."
INDEX { mspIndex }
::= { mspTable 1 }
MspEntry ::= SEQUENCE
{
mspIndex INTEGER, -- msTTPIndex = mspWorkingPointer
mspWorkingPointer INTEGER, -- mst working
mspProtectionPointer INTEGER, -- mst protection
mspType MspType,
mspDir MspDirection,
mspTraffic TrafficStatus,
mspRevertive SagemBoolean,
mspWtr INTEGER,
mspSfSdPriority MspPriority,
mspSfSdHoldOffTime INTEGER,
mspCommand MspCommand,
mspInitiator MspInitiator,
mspStatus MspStatus,
mspMonitor SagemBoolean,
mspFailure MspFailure,
mspSeverity Severity,
mspPam Severity,
mspScm Severity,
mspOtm Severity
}
mspIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value which identify a particular multiplex section protection.
This index is equal to an msTTPIndex(=spiIndex) which gives the interface involved .
The value of index is a constant assigned to an entry at
equipment design time. It is usualy related to harware."
::= { mspEntry 1 }
mspWorkingPointer OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to the object which sends the data flow to this
function on working synchronous port interface side.
In most equipments, this value cannot be changed and points to
the working MST it is hard wired with."
::= { mspEntry 2 }
mspProtectionPointer OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A reference to the object which sends the data flow to this
function on protection synchronous port interface side.
In most equipments, this value cannot be changed and points to
the protection MST it is hard wired with.
When this variable is setting, the protection is created and activated (if it's possible).
The two considerated sections must have the same Stm Level. "
::= { mspEntry 3 }
mspType OBJECT-TYPE
SYNTAX MspType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indication of the protection type."
::= { mspEntry 4 }
mspDir OBJECT-TYPE
SYNTAX MspDirection
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indication of the direction."
::= { mspEntry 5 }
mspTraffic OBJECT-TYPE
SYNTAX TrafficStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this field indicates the protection switch position."
::= { mspEntry 6 }
mspRevertive OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If the value is true the msp function is allowed to spontaneously
switch back to working chanel when it is available.
If not, the msp can switch back to working chanel only if
protection chanel fails."
::= { mspEntry 7 }
mspWtr OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time (in seconds) the msp function waits before
considering a chanel as good after a fail."
::= { mspEntry 8 }
mspSfSdPriority OBJECT-TYPE
SYNTAX MspPriority
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Signal Fail and Signal Degrade can be treated according to two set
of priority. The equipement will send SF and SD events according to
the value of this field."
::= { mspEntry 9 }
mspSfSdHoldOffTime OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The period (in tenth of seconds) during which a
sf or a Signal Degrade is
ignored by the MSP switch."
::= { mspEntry 10 }
mspCommand OBJECT-TYPE
SYNTAX MspCommand
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Manual or forced commands can be apply to the protection switch.
The forced and manual switch can be refused or cleared by equipment
if a higher priority APS command is received or if the protection chanel
is down.
When this field is set to manual or forced, the mspTraffic field
becomes read-write, and a set can be issued to specifie on which
chanel the command does apply.
Commands:
LP (Lockout of Protection)
LW (Lockout of Working channel)
FSW (Forced Switch of a Working channel to protection)
FSP (Forced Switch of a Protection channel to working) case 1+1
MSW (Manual Switch of a Working channel to protection)
MSp (Manual Switch of a Protection channel to working) case 1+1
EXER (EXERcise)
"
::= { mspEntry 11 }
mspInitiator OBJECT-TYPE
SYNTAX MspInitiator
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the initiator equipment."
::= { mspEntry 12 }
mspStatus OBJECT-TYPE
SYNTAX MspStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the initiator equipment status :
lockoutProtection(15),
forcedSwitch(14),
highSF(13),
lowSF(12),
highSD(11),
lowSD(10),
manualSwitch(8),
waitToRestore(6),
exercise(4),
reverseRequest(2),
doNotRevert(1),
noRequest(0) "
::= { mspEntry 13 }
mspMonitor OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the value of this field is set to false, the failure detection
is stopped for this multiplex section protection."
::= { mspEntry 14 }
mspFailure OBJECT-TYPE
SYNTAX MspFailure
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active failures on multiplex section protection."
::= { mspEntry 15 }
mspSeverity OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to failure severity for multiplex section protection."
::= { mspEntry 16 }
mspPam OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Severity associed with Protection Architecture Mismatch failure
for multiplex section protection."
::= { mspEntry 20 }
mspScm OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Severity associed with Selector Control Mismatch failure
for multiplex section protection."
::= { mspEntry 21 }
mspOtm OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Severity associed with Operation Type Mismatch failure
for multiplex section protection."
::= { mspEntry 22 }
-- End of multiplex section protection description
--*******************************************************************
--* multiplex section shared protection ring (ms SpRing)
--*******************************************************************
MsSPRingFailure ::= INTEGER
{
none(0), ato(1), arv(2), aun (3), ptm (4), mms (5), exr(6)
}
MsSPRingStatus ::= INTEGER
{
off(19),lockoutProtection (15), forcedSwitchR (13), sfR (11), sdR (8),
manualSwitchR (6),
waitToRestore (5), exerR (3), reverseRequestR (1), noRequest (0)
}
MsSPRingCommand ::= INTEGER
{
clear(16),lpS(15),fsR(13),msR(6),exerR(3),on(20),off(19)
}
MsSPRingID ::= INTEGER
{
node0(0), node1(1), node2(2),node3 (3), node4 (4),
node5(5), node6(6), node7(7),node8 (8), node9 (9),
node10(10), node11(11), node12(12),node13 (13), node14 (14),
node15(15), nodeUNK(255)
}
State ::= INTEGER
{
off (0),
idle (1),
pass (2),
switch (3),
unknown (4)
}
msSPRingNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of multiplex section protection in equipment."
::= { msSPRing 1 }
msSPRingTable OBJECT-TYPE
SYNTAX SEQUENCE OF MsSPRingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of multiplex section protection in equipment."
::= { msSPRing 6 }
msSPRingEntry OBJECT-TYPE
SYNTAX MsSPRingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular multiplex section protection of the equipment.
Each entry is created in using the msTTPTable of the Sdh-Ets MIB.
spiIndex gives the interface involved (line east or west)"
INDEX { msSPRingIndex }
::= { msSPRingTable 1 }
MsSPRingEntry ::= SEQUENCE
{
msSPRingIndex INTEGER, -- West index
msSPRingWestPointer INTEGER, -- vers mst
msSPRingEastPointer INTEGER, -- vers mst
msSPRingWtr INTEGER, -- 0-30 min,+/-1min,def 5min
msSPRingSfSdHoldOffTime INTEGER,
msSPRingCommandSide INTEGER, -- vers mst
msSPRingCommand MsSPRingCommand,
msSPRingInitiator1 MsSPRingID, -- 0..15
msSPRingInitiator2 MsSPRingID, -- 0..15
msSPRingNodeState State,
msSPRingSwitchingSide INTEGER, -- vers mst
msSPRingWestTraffic TrafficStatus,
msSPRingEastTraffic TrafficStatus,
msSPRingWestStatus MsSPRingStatus,
msSPRingEastStatus MsSPRingStatus,
msSPRingMonitor SagemBoolean,
msSPRingFailure MsSPRingFailure,
msSPRingSeverity Severity,
msSPRingAto Severity,
msSPRingArv Severity,
msSPRingAun Severity,
msSPRingPtm Severity,
msSPRingMms Severity,
msSPRingExr Severity,
msSPRingSimpleFailure SagemBoolean,
msSPRingId MsSPRingID
}
msSPRingIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value which identify a particular SPRing = West STM index."
::= { msSPRingEntry 1 }
msSPRingWestPointer OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to the object which sends the data flow to this
function on synchronous port interface side.
In most equipments, this value cannot be changed and points to
the West MST it is hard wired with."
::= { msSPRingEntry 2 }
msSPRingEastPointer OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A reference to the object which sends the data flow to this
function on synchronous port interface side.
In most equipments, this value cannot be changed and points to
the East MST it is hard wired with.
When this variable is setting, the protection is created and activated (if it's possible).
The two considerated sections must have the same Stm Level."
::= { msSPRingEntry 3 }
msSPRingWtr OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time (in seconds) the spring function waits before
considering a chanel as good after a fail."
::= { msSPRingEntry 5 }
msSPRingSfSdHoldOffTime OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The period (in tenth of seconds) during which a
sf or a Signal Degrade is ignored by the SPRing switch."
::= { msSPRingEntry 6 }
msSPRingCommandSide OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Side of the command"
::= { msSPRingEntry 7 }
msSPRingCommand OBJECT-TYPE
SYNTAX MsSPRingCommand
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Manual or forced commands can be apply to the protection switch.
"
::= { msSPRingEntry 8 }
msSPRingInitiator1 OBJECT-TYPE
SYNTAX MsSPRingID
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference(ID) to the equipment that initiate the SWITCH; this is mainly the Master
when the equipment is in SWITCH state; in some case like bidirectional SF both equipment
of the couple equipment are Master.
In PASS state Master and Slave are undeterminated"
::= { msSPRingEntry 10 }
msSPRingInitiator2 OBJECT-TYPE
SYNTAX MsSPRingID
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference(ID) to the equipment that respond to the SWITCH; this is mainly the Slave
when the equipment is in SWITCH state; in some case like bidirectional SF both equipment
of the couple equipment are Master.
In PASS state Master and Slave are undeterminated"
::= { msSPRingEntry 11 }
msSPRingNodeState OBJECT-TYPE
SYNTAX State
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { msSPRingEntry 29 }
msSPRingSwitchingSide OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Switching SideSide"
::= { msSPRingEntry 30 }
msSPRingWestTraffic OBJECT-TYPE
SYNTAX TrafficStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this field indicates the protection switch position."
::= { msSPRingEntry 31 }
msSPRingEastTraffic OBJECT-TYPE
SYNTAX TrafficStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this field indicates the protection switch position."
::= { msSPRingEntry 32 }
msSPRingWestStatus OBJECT-TYPE
SYNTAX MsSPRingStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the local status:
OFF (19), lockoutProtection (16), forcedSwitch-R(13),sf-R(11),sd-R(8),
manualSwitch-R(6),
waitToRestore(5),exer-R(3),noRequest(0)"
::= { msSPRingEntry 33 }
msSPRingEastStatus OBJECT-TYPE
SYNTAX MsSPRingStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the local status:
OFF (19), lockoutProtection (16), forcedSwitch-R(13),sf-R(11),sd-R(8),
manualSwitch-R(6),
waitToRestore(5),exer-R(3),noRequest(0)"
::= { msSPRingEntry 34 }
msSPRingMonitor OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When the value of this field is set to false, the failure detection
is stopped for this multiplex section protection."
::= { msSPRingEntry 12 }
msSPRingFailure OBJECT-TYPE
SYNTAX MsSPRingFailure
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active failures on multiplex section protection"
::= { msSPRingEntry 13 }
msSPRingSeverity OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to failure severity for multiplex section protection."
::= { msSPRingEntry 14 }
msSPRingAto OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Severity associed with APS Time Out failure failure
for MS-SPRing."
::= { msSPRingEntry 21 }
msSPRingArv OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Severity associed with APS Rules Violation failure failure
for MS-SPRing."
::= { msSPRingEntry 22 }
msSPRingAun OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Severity associed with APS Unknown Node failure failure
for MS-SPRing."
::= { msSPRingEntry 23 }
msSPRingPtm OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Severity associed with Potential Traffic Misconnection failure
for MS-SPRing."
::= { msSPRingEntry 24 }
msSPRingMms OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Severity associed with Mutiple Multiplex Section Fail failure
for MS-SPRing."
::= { msSPRingEntry 25 }
msSPRingExr OBJECT-TYPE
SYNTAX Severity
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Severity associed with EXeRcise failure
for MS-SPRing."
::= { msSPRingEntry 26 }
msSPRingSimpleFailure OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicate if simple or multi ring failure must be considerated"
::= { msSPRingEntry 27 }
msSPRingId OBJECT-TYPE
SYNTAX MsSPRingID
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ring Identifier of the equipement"
::= { msSPRingEntry 28 }
--*******************************************************************
msSPRingTopoMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF MsSPRingTopoMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Topology Map of the ring = West STM index + Val (1<=Val<=16)."
::= { msSPRing 11 }
msSPRingTopoMapEntry OBJECT-TYPE
SYNTAX MsSPRingTopoMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular entry of the ring topology map."
INDEX { msSPRingTopoMapIndex }
::= { msSPRingTopoMapTable 1 }
-- 16 entries in this table
MsSPRingTopoMapEntry ::= SEQUENCE
{
msSPRingTopoMapIndex INTEGER,
msSPRingTopoMapID MsSPRingID
}
msSPRingTopoMapIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"index"
::= { msSPRingTopoMapEntry 1 }
msSPRingTopoMapID OBJECT-TYPE
SYNTAX MsSPRingID
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"identifier of the node"
::= { msSPRingTopoMapEntry 2 }
--*******************************************************************
MisconMapType ::= INTEGER
{
terminated(1), passedThrough (2)
}
MsSPRingSide ::= INTEGER
{
west(0),east(1), unknown(2)
}
msSPRingMisconMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF MsSPRingMisconMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Connectivity (misconnection) Map of the ring."
::= { msSPRing 21 }
msSPRingMisconMapEntry OBJECT-TYPE
SYNTAX MsSPRingMisconMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular entry of the ring connectivity (misconnection) map.
All entries are created after setting the msSPRingWestPointer."
INDEX { msSPRingMisconMapIndex }
::= { msSPRingMisconMapTable 1 }
-- 8 West + 8 East entries in this table for each SPRing
MsSPRingMisconMapEntry ::= SEQUENCE
{
msSPRingMisconMapIndex INTEGER,
msSPRingMisconMapSide MsSPRingSide,
msSPRingMisconMapIn MsSPRingID,
msSPRingMisconMapOut MsSPRingID ,
msSPRingMisconMapTimeSlot INTEGER,
msSPRingMisconMapType MisconMapType,
msSPRingMisconMapLOAccess SagemBoolean
}
msSPRingMisconMapIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index = West STM index + Val (1<=Val<=16)
ADR2500c : val = 1 to 8 for West and 9 to 16 for East"
::= { msSPRingMisconMapEntry 1 }
msSPRingMisconMapSide OBJECT-TYPE
SYNTAX MsSPRingSide
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Side (WestPointer/msSPRingEast) of the interface that supports the AU4"
::= { msSPRingMisconMapEntry 2 }
msSPRingMisconMapIn OBJECT-TYPE
SYNTAX MsSPRingID
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Node of the ring where the Au4 traffic enters the ring"
::= { msSPRingMisconMapEntry 3 }
msSPRingMisconMapOut OBJECT-TYPE
SYNTAX MsSPRingID
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Node of the ring where the Au4 traffic exits the ring"
::= { msSPRingMisconMapEntry 4 }
msSPRingMisconMapTimeSlot OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time Slot assignment for the AU4"
::= { msSPRingMisconMapEntry 5 }
msSPRingMisconMapType OBJECT-TYPE
SYNTAX MisconMapType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If the value is equal to terminated, the traffic in the ring is inserted
or extracted at this node.
If the value is equal to passedThrough the traffic only cross the node"
::= { msSPRingMisconMapEntry 6 }
msSPRingMisconMapLOAccess OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"True if the AU4 is accessed at LO layers somewhere in the ring"
::= { msSPRingMisconMapEntry 7 }
--*******************************************************************
msSPRingNUTTable OBJECT-TYPE
SYNTAX SEQUENCE OF MsSPRingNUTEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Topology Map of the ring."
::= { msSPRing 31 }
msSPRingNUTEntry OBJECT-TYPE
SYNTAX MsSPRingNUTEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular entry of the ring topology map."
INDEX { msSPRingNUTIndex }
::= { msSPRingNUTTable 1 }
-- 8 entries in this table
MsSPRingNUTEntry ::= SEQUENCE
{
msSPRingNUTIndex INTEGER, -- time slot
msSPRingNUTisNut SagemBoolean
}
msSPRingNUTIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"AU4 index = West STM index + Val (Val = working timeSlot; 1<=Val<=8)"
::= { msSPRingNUTEntry 1 }
msSPRingNUTisNut OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define if the traffic is used for NUT Traffic"
::= { msSPRingNUTEntry 2 }
-- End of multiplex section shared protection ring (ms spRing)
--*******************************************************************
--* sncp
--*******************************************************************
LinkType ::= INTEGER
{
unknown(0),
au(1),
au4c(2),
au16c(3),
tu3(10),
tu12(20)
}
TriggerCriterion ::= INTEGER
{
none(0),
sncI(1),
sncN(2),
sncIRdi(3),
sncNRdi(4)
}
SNCStateProcess ::= INTEGER
{
nrnormal(0),
nrsecours(1),
wtr(2),
dontRev(3),
mssecours(4),
msnormal(5),
sdnormal(6),
sdsecours(7),
sfnormal(8),
fssecours(9),
sfsecours(10),
fsnormal(11),
lockout(12)
-- msRDInormal(11),
-- sfmsRDInormal(12),
-- sdmsRDInormal(13),
-- msRDIsecours(16),
-- sfmsRDIsecours (17),
-- sdmsRDIsecours(18)
}
SNCCommand ::= INTEGER
{
clear(0),
manualWorking(1),
manualProtection(2),
forcedWorking(3),
forcedProtection(4),
lockout(5),
off(19),
on(20)
}
sncNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of snc in equipment."
::= { sncp 1 }
sncTable OBJECT-TYPE
SYNTAX SEQUENCE OF SncEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of snc protection in equipment."
::= { sncp 2 }
sncEntry OBJECT-TYPE
SYNTAX SncEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular SNC protection which is created in using the linkTable of the Xconnection MIB."
INDEX { sncIndex }
::= { sncTable 1 }
SncEntry ::=
SEQUENCE {
sncIndex INTEGER, -- linkIndex
sncLinkType LinkType,
sncCTPSink INTEGER,
sncCTPSourceW INTEGER,
sncCTPSourceP INTEGER,
sncTrafficStatus TrafficStatus,
sncWorkingTriggerType TriggerCriterion,
sncProtectionTriggerType TriggerCriterion,
sncRevertive SagemBoolean,
sncWtr INTEGER,
sncStateProcess SNCStateProcess,
sncHoldOffTime INTEGER,
sncCommand SNCCommand
}
sncIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sncIndex = 1000*sncType + sncTTPSink = linkIndex"
::= { sncEntry 1 }
sncCTPSink OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this field is the index of the Output Connection to which
an snc function is applied."
::= { sncEntry 2 }
sncLinkType OBJECT-TYPE
SYNTAX LinkType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Trail level of the connection"
::= { sncEntry 3 }
sncCTPSourceW OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this field indicates the Working Input Connection Point which
composes the protection link of the Output Connection Point (sncIndex)."
::= { sncEntry 4 }
sncCTPSourceP OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this field indicates the Protected Input Connection Point which
composes the protection link of the Output Connection Point (sncIndex).
When this variable is setting, the protection is created and activated (if it's possible). "
::= { sncEntry 5 }
sncTrafficStatus OBJECT-TYPE
SYNTAX TrafficStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This field indicates the Protection unit switch position."
::= { sncEntry 6}
sncWorkingTriggerType OBJECT-TYPE
SYNTAX TriggerCriterion
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The value of this field is the criterion to trigger a switch for the Working Input
Connection Point.SNC/I uses SF criterion for switching: TU-AIS/TU-LOP for VC12/VC3 ,
AU-AIS/AU-LOP for VC4 and , by extension, ppiLOS and ppiAIS for pdh inputs.
SNC/N uses also SD criterion for switching: SD-V5 for VC12,
SD-B3 for VC3/VC4.
SNC+LAN adds MS-RDI as switching criterion for LAN connection.
NONE means that just board extractions and some board failures activate switching."
::= { sncEntry 8 }
sncProtectionTriggerType OBJECT-TYPE
SYNTAX TriggerCriterion
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The value of this field is the criterion to trigger a switch for the Protection Input
Connection Point. SNC/I uses SF criterion for switching: TU-AIS/TU-LOP for VC12/VC3 ,
AU-AIS/AU-LOP for VC4 and , by extension, ppiLOS and ppiAIS for pdh inputs.
SNC/N uses also SD criterion for switching: SD-V5 for VC12,
SD-B3 for VC3/VC4.
SNC+LAN adds MS-RDI as switching criterion for LAN connection.
NONE means that just board extractions and some board failures activate switching."
::= { sncEntry 9 }
sncRevertive OBJECT-TYPE
SYNTAX SagemBoolean
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If the value is true the Protection unit function is allowed
to spontaneously switch back to working chanel when it is available.
If not, the snc can switch back to working chanel only if
protection chanel fails."
::= { sncEntry 20 }
sncWtr OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time (in seconds) the Protection unit function waits before
considering a chanel as good after a fail."
::= { sncEntry 21 }
sncStateProcess OBJECT-TYPE
SYNTAX SNCStateProcess
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The value of this field indicates the state of the snc protection process."
::= { sncEntry 22 }
sncHoldOffTime OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time in tenth of seconds during which a protection trigger criterion is
ignored."
::= { sncEntry 23 }
sncCommand OBJECT-TYPE
SYNTAX SNCCommand
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Manual or forced commands can be apply to the protection unit.
The forced and manual switch can be refused or cleared by equipment
if a higher priority evenement is received or if the protection chanel
is down."
::= { sncEntry 24 }
--*******************************************************************
--* Card Protection
--*******************************************************************
CardpFamily ::= INTEGER
{
none(0),
switch (1)
}
CardpCommand ::= INTEGER
{
clear(0),
manualSwitch (1)
}
CardpStatus ::= INTEGER
{
notSwitched(0),
manualSwitch (1),
automaticSwitch (2)
}
cardpNumber OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of card protections in equipment."
::= { cardp 1 }
cardpTable OBJECT-TYPE
SYNTAX SEQUENCE OF CardpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of card protections in equipment."
::= { cardp 2 }
cardpEntry OBJECT-TYPE
SYNTAX CardpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular card protection which is created in using the boardTable of the Shelf MIB."
INDEX { cardpIndex }
::= { cardpTable 1 }
CardpEntry ::=
SEQUENCE {
cardpIndex INTEGER, -- working BoardIndex
cardpBoardFamily CardpFamily,
cardpReliefIndex INTEGER, -- protection BoardIndex
cardpTrafficStatus TrafficStatus,
cardpCommand CardpCommand,
cardpStatus CardpStatus
}
cardpIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"cardpIndex = boardIndex in the Shelf Mib.
This index points to the working board."
::= { cardpEntry 1 }
cardpBoardFamily OBJECT-TYPE
SYNTAX CardpFamily
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This field indicates the family of board concerned by the protection."
::= { cardpEntry 2 }
cardpReliefIndex OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A reference to the relief card. It must be an existing index in the boardTable of Shelf Mib.
The relief card and the protected Card must below to the same familly.
When this variable is setting, the protection is created and activated (if it's possible)."
::= { cardpEntry 3 }
cardpTrafficStatus OBJECT-TYPE
SYNTAX TrafficStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indication of the protection switch position."
::= { cardpEntry 4 }
cardpCommand OBJECT-TYPE
SYNTAX CardpCommand
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Manual commands can be apply to the protection unit.
The manual switch can be refused or cleared by equipment
if a higher priority evenement is received or if the protection chanel
is down."
::= { cardpEntry 5 }
cardpStatus OBJECT-TYPE
SYNTAX CardpStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indication of the current protection status"
::= { cardpEntry 6 }
END