2924 lines
93 KiB
Plaintext
2924 lines
93 KiB
Plaintext
--*******************************************************************
|
|
--* SAGEM SA *
|
|
--*******************************************************************
|
|
--*******************************************************************
|
|
|
|
-- Filename: sdh-ETS
|
|
-- File type: .mib
|
|
--
|
|
-- Description: SNMPc source Mib file.
|
|
-- The MIB module defines SDH transmition part of an equipment
|
|
-- as it's modeled in ETSI ETS 300 304.
|
|
--
|
|
-- Version: 19 11 2002
|
|
--
|
|
-- Date(DD MM YYYY): 15 11 02 last update for IONOS NMS
|
|
--
|
|
-- Contact: D. Mobuchon, F. Bonnevialle
|
|
--
|
|
-- History:
|
|
-- Name: F.Bonnevialle
|
|
-- Date: 12 12 2000
|
|
-- Desc: original
|
|
--
|
|
-- Name: S.LAURENT
|
|
-- Date: 08 02 2001
|
|
-- Desc: The synchronization functions of this MIB are deleted
|
|
-- and put in a new MIB SYNCHRO.
|
|
--
|
|
-- Name: S.LAURENT
|
|
-- Date: 11 04 2001
|
|
-- Desc: * Modifications in MSA, VC4 and AU4 Tables.
|
|
--
|
|
-- Name: S.LAURENT
|
|
-- Date: 25 04 2001
|
|
-- Desc: * Name Modification: ppi -> nspi (for not spi).
|
|
-- This change allow to accept more non-sdh interfaces such
|
|
-- as atm or Ethernet (which are not plesiochronous kind).
|
|
-- * Size Modification of the vc4PathTrace Strings
|
|
-- * deletion of alarme and severity fields in MsaTable.
|
|
--
|
|
-- Name: F.Bonnevialle
|
|
-- Date: 30 04 2001
|
|
-- Desc: Description modification to match with ETS-300 304
|
|
--
|
|
-- Name: S.LAURENT
|
|
-- Date: 09 08 2001
|
|
-- Desc: * Rights access modification on variables: vc12TTPSinkPointer
|
|
-- and vc3TTPSinkPointer
|
|
-- * TUG3 Object Deletion: This object didn't give any adding
|
|
-- information.
|
|
-- * Deletion of tu3CTPLom and tu12CTPLom variables
|
|
-- * Creation of au4CTPLom Variable adding to a new value in Au4CTPFailure Type( lom(3))
|
|
--
|
|
-- Name: S.LAURENT
|
|
-- Date: 30 08 2001
|
|
-- Desc: * comments modification on Au4CTPTable variables
|
|
-- * Add a new value 'tu(20)' in AU4CTPType
|
|
-- * Deletion of tu3CTPLom and tu12CTPLom variables
|
|
-- * Creation of au4CTPLom Variable adding to a new value in Au4CTPFailure Type( lom(3))
|
|
--
|
|
-- Name: S.LAURENT
|
|
-- Date: 22 05 2002
|
|
-- Desc: * Creation of ChannelTable
|
|
-- * Creation of BandwidthTable
|
|
-- * Add a new value 'channel(4)' in NspiSrcType
|
|
--
|
|
-- Name: F.Bonnevialle
|
|
-- Date: 15 11 2002
|
|
-- Desc: Modification for SilverCreek Compiler
|
|
--
|
|
--*******************************************************************
|
|
--*******************************************************************
|
|
--* Copyright (c) 2002, SAGEM , All rights reserved. *
|
|
--*******************************************************************
|
|
|
|
|
|
|
|
|
|
--*******************************************************************
|
|
-- MIB: SDH-ETS-MIB
|
|
--*******************************************************************
|
|
SDH-ETS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
--*******************************************************************
|
|
-- IMPORTS
|
|
--*******************************************************************
|
|
|
|
IMPORTS
|
|
sagemDr FROM SAGEM-DR-MIB
|
|
SagemBoolean, Severity FROM EQUIPMENT-MIB
|
|
MODULE-IDENTITY,OBJECT-TYPE FROM SNMPv2-SMI
|
|
DisplayString FROM SNMPv2-TC; --RFC1213-MIB;
|
|
|
|
sdhEts MODULE-IDENTITY
|
|
LAST-UPDATED "0205220000Z"
|
|
ORGANIZATION "SAGEM-Tolbiac drd/ddp/tmhd"
|
|
CONTACT-INFO
|
|
" "
|
|
DESCRIPTION
|
|
"The MIB module defines SDH transmition part of an equipment
|
|
This MIB use the logical model defined in ETSI ETS 300 304.
|
|
ETS 300 304 (February 1997) defines the SDH information
|
|
model for the Network Element.
|
|
This MIB refers to SHELF-MIB
|
|
for the definition of the Board that supports the interface.
|
|
This MIB is refered by XCON-MIB that uses
|
|
the definition of termination point to create cross connection.
|
|
This MIB also define configuration of the different SDH blocs
|
|
such as alarm monitoring and severity and give the current status of
|
|
the termination point.
|
|
"
|
|
::= { sagemDr 110 }
|
|
|
|
|
|
-- Synchronous Physical Interface Trail Termination Point
|
|
-- Reference to ETS 300 304:
|
|
-- electricalSPITTPSink, electricalSPITTPSink
|
|
-- opticalSPITTPSink, opticalSPITTPSink
|
|
spiTTP OBJECT IDENTIFIER ::= { sdhEts 10 }
|
|
|
|
-- regenerator section terminaison Trail Termination Point
|
|
-- Reference to ETS 300 304:
|
|
-- rsTTPSink, rsTTPSink
|
|
rsTTP OBJECT IDENTIFIER ::= { sdhEts 20 }
|
|
|
|
-- regenerator section terminaison Connection Termination Point
|
|
-- Reference to ETS 300 304:
|
|
-- rsCTPSink, rsCTPSink
|
|
rsCTP OBJECT IDENTIFIER ::= { sdhEts 25 }
|
|
|
|
|
|
-- multiplex section terminaison Trail Termination Point
|
|
-- Reference to ETS 300 304:
|
|
-- msTTPSink, msTTPSink
|
|
msTTP OBJECT IDENTIFIER ::= { sdhEts 30 }
|
|
|
|
-- multiplex section terminaison Connection Termination Point
|
|
-- Reference to ETS 300 304:
|
|
-- msCTPSink, msCTPSink
|
|
msCTP OBJECT IDENTIFIER ::= { sdhEts 35 }
|
|
|
|
-- multiplex section adaptation
|
|
msa OBJECT IDENTIFIER ::= { sdhEts 60 }
|
|
|
|
-- administrative unit order 4 Connection Termination Point
|
|
-- Reference to ETS 300 304:
|
|
-- au4CTPSink, au4CTPSink
|
|
au4CTP OBJECT IDENTIFIER ::= { sdhEts 70 }
|
|
|
|
-- virtual container order 4 Trail Termination Point
|
|
-- Reference to ETS 300 304:
|
|
-- vc4TTPSink, vc4TPSink
|
|
vc4TTP OBJECT IDENTIFIER ::= { sdhEts 100 }
|
|
|
|
-- tributary unit order 3 Connection Termination Point
|
|
-- Reference to ETS 300 304:
|
|
-- tu3CTPSink, tu3CTPSink
|
|
tu3CTP OBJECT IDENTIFIER ::= { sdhEts 120 }
|
|
|
|
-- virtual container order 3 Trail Termination Point
|
|
-- Reference to ETS 300 304:
|
|
-- vc3TTPSink, vc3TTPSink
|
|
vc3TTP OBJECT IDENTIFIER ::= { sdhEts 130 }
|
|
|
|
-- tributary unit order 12 Connection Termination Point
|
|
-- Reference to ETS 300 304:
|
|
-- tu12CTPSink, tu12CTPSink
|
|
tu12CTP OBJECT IDENTIFIER ::= { sdhEts 140 }
|
|
|
|
-- virtual container order 12 Trail Termination Point
|
|
-- Reference to ETS 300 304:
|
|
-- vc12CTPSink, vc12CTPSink
|
|
vc12TTP OBJECT IDENTIFIER ::= { sdhEts 150 }
|
|
|
|
-- non sdh Connection termination point Connection Termination Point
|
|
-- Reference to ETS 300 304:
|
|
-- p12CTPSink, p12CTPSink, p31CTPSink, p31CTPSink, ...
|
|
-- for PDH terminaison.
|
|
-- The object (table/type) can be updated to match other kind of
|
|
-- non SDH terminaison such as Ethernet or ATM interface over SDH
|
|
nspiCTP OBJECT IDENTIFIER ::= { sdhEts 160 }
|
|
|
|
-- non sdh physical port Trail Termination Point
|
|
-- Reference to ETS 300 304:
|
|
-- p12TTPSink, p12TTPSink, p31TTPSink, p31TTPSink, ...
|
|
-- for PDH terminaison.
|
|
-- The object (table/type) can be updated to match other kind of
|
|
-- non SDH terminaison such as Ethernet or ATM interface over SDH
|
|
nspiTTP OBJECT IDENTIFIER ::= { sdhEts 170 }
|
|
|
|
-- Channel Layer
|
|
channel OBJECT IDENTIFIER ::= { sdhEts 180 }
|
|
|
|
-- Non sdh adaptation layer: Bandwidth
|
|
bandwidth OBJECT IDENTIFIER ::= { sdhEts 190 }
|
|
|
|
|
|
|
|
-- Note on the srcPointer ans sinkPointer
|
|
-- The transmission functions and interfaces include a set of integer named
|
|
-- "Pointer".
|
|
-- These Pointers are used to link together the different SDH level.
|
|
-- SinkPointer is used to go UP in the hierarchie (go to the physical interface)
|
|
-- and SourcePointer is used to go Down (go to VC and sub VC)
|
|
-- These pointer can be used to retreive all the contained TTP
|
|
-- or to retrieve the containing TTP and the physical interface (and board)
|
|
|
|
-- Note on CTPIndex
|
|
-- A CTP index is used to find a possible Connection Termination Point
|
|
-- supported by a Trail Termination Point.
|
|
-- If the CTP is not used for a Cross Connection the value is set to 0.
|
|
|
|
-- Remark
|
|
-- rstCTP and mstCTP are not implemented. The MIB can be upgraded if these
|
|
-- level of Connection are used.
|
|
|
|
--*******************************************************************
|
|
--* TTP synchronous physical interface (spi)
|
|
--*******************************************************************
|
|
SpiTTPFailure ::= INTEGER
|
|
{
|
|
none(0),
|
|
los(1),
|
|
tf(2),
|
|
losTf(3)
|
|
}
|
|
|
|
Loopback ::= INTEGER
|
|
{
|
|
none(0),
|
|
line(1),
|
|
equipment(2),
|
|
lineEquipement(3)
|
|
}
|
|
|
|
STMLevel ::= INTEGER
|
|
{
|
|
stm1(1),
|
|
stm4(4),
|
|
stm16(16),
|
|
stm64(64)
|
|
}
|
|
SpiTTPType ::= INTEGER
|
|
{
|
|
electrical(0),
|
|
optical(1)
|
|
}
|
|
|
|
spiTTPNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of synchronous physical interface in equipment
|
|
= number of element in spiTTPTable "
|
|
::= { spiTTP 1 }
|
|
|
|
spiTTPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SpiTTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of synchronous physical interface in equipment."
|
|
::= { spiTTP 2 }
|
|
|
|
spiTTPEntry OBJECT-TYPE
|
|
SYNTAX SpiTTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular synchronous physical interface of the equipment."
|
|
INDEX { spiTTPIndex }
|
|
::= { spiTTPTable 1 }
|
|
|
|
SpiTTPEntry ::= SEQUENCE
|
|
{
|
|
spiTTPIndex INTEGER,
|
|
spiTTPStmLevel STMLevel,
|
|
spiTTPType SpiTTPType,
|
|
spiTTPName DisplayString,
|
|
spiTTPBoardIndex INTEGER,
|
|
spiTTPBoardAcces INTEGER,
|
|
spiTTPMonitor SagemBoolean,
|
|
spiTTPFailure SpiTTPFailure,
|
|
spiTTPSeverity Severity,
|
|
spiTTPLoopback Loopback,
|
|
spiTTPLos Severity,
|
|
spiTTPTf Severity
|
|
}
|
|
|
|
spiTTPIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular
|
|
synchronous physical interface.
|
|
The value of this index is a constant value assigned to an entry at
|
|
equipment design time. It is usualy related to harware.
|
|
Exemple:
|
|
For ADR155c equipement index are 1,64,127,190 for STM1 interfaces.
|
|
For ADR2500c equipement index are:
|
|
1,1009,2017,3025,4033,5041,6049,7057 for 8 STM16 or 8 STM4,
|
|
1,253,505,757 1009,1261,1513,1765 |
|
|
2017,2269,2521,2773 3025,3277,3529,3781 | --> for 8 (4*STM1)
|
|
4033,4285,4537,4789 5041,5293,5545,5797 |
|
|
6049,6301,6553,6805 7057,7309,7561,7813 | "
|
|
::= { spiTTPEntry 1 }
|
|
|
|
spiTTPStmLevel OBJECT-TYPE
|
|
SYNTAX STMLevel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The STM-n level of the interface."
|
|
::= { spiTTPEntry 2 }
|
|
|
|
spiTTPType OBJECT-TYPE
|
|
SYNTAX SpiTTPType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The kind of the interface: electrical or optical"
|
|
::= { spiTTPEntry 3 }
|
|
|
|
spiTTPName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string which identifies the particular entry among the
|
|
synchronous physical interface entries. "
|
|
::= { spiTTPEntry 4 }
|
|
|
|
spiTTPBoardIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of the Board that supports the physical acces
|
|
of this interface. This index refers to another MIB that defines
|
|
the board"
|
|
::= { spiTTPEntry 5 }
|
|
|
|
spiTTPBoardAcces OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Friendly Index of the physical acces on the Board that supports
|
|
the interface"
|
|
::= { spiTTPEntry 6 }
|
|
|
|
spiTTPMonitor OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the value of this field is set to false, the failure detection
|
|
is stopped for this synchronous physical interface."
|
|
::= { spiTTPEntry 7 }
|
|
|
|
spiTTPFailure OBJECT-TYPE
|
|
SYNTAX SpiTTPFailure
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active failures on synchronous physical interface"
|
|
::= { spiTTPEntry 8 }
|
|
|
|
spiTTPSeverity OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with active failure for synchronous physical interface."
|
|
::= { spiTTPEntry 9 }
|
|
|
|
spiTTPLoopback OBJECT-TYPE
|
|
SYNTAX Loopback
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This field gives the active loopback status on the
|
|
synchronous physical interface.
|
|
When its value is `line' the data flow recieved from the port side
|
|
is sent back to the line.
|
|
When its value is `equipment' the data flow recieved form equipment
|
|
side is send back.
|
|
The field can be set to a particular loopback value, even if there
|
|
no garantee that the loopback is really done. The real loopback status
|
|
of the interface must be checked in the response.
|
|
The loopback can be cleared by the equipment when it cannot remain
|
|
for any reason."
|
|
::= { spiTTPEntry 10 }
|
|
|
|
spiTTPLos OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Loss Of Signal failure
|
|
for synchronous physical interface."
|
|
::= { spiTTPEntry 20 }
|
|
|
|
spiTTPTf OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Tranmit Fail failure
|
|
for synchronous physical interface."
|
|
::= { spiTTPEntry 21 }
|
|
-- End of synchronous physical interface description
|
|
|
|
|
|
--*******************************************************************
|
|
--* regenerator section terminaison (rst)
|
|
--*******************************************************************
|
|
RsTTPFailure ::= INTEGER
|
|
{
|
|
none(0), lof(1)
|
|
}
|
|
|
|
EOWMode ::= INTEGER
|
|
{
|
|
codirectional(0),
|
|
contradirectional(1)
|
|
}
|
|
|
|
rsTTPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RsTTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of regenerator section terminaison in equipment."
|
|
::= { rsTTP 2 }
|
|
|
|
rsTTPEntry OBJECT-TYPE
|
|
SYNTAX RsTTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular regenerator section terminaison of the equipment."
|
|
INDEX {rsTTPIndex}
|
|
::= { rsTTPTable 1 }
|
|
|
|
RsTTPEntry ::= SEQUENCE {
|
|
rsTTPIndex INTEGER, -- spi index
|
|
rsTTPMonitor SagemBoolean,
|
|
rsTTPName DisplayString,
|
|
rsTTPFailure RsTTPFailure,
|
|
rsTTPSeverity Severity,
|
|
rsTTPEOWMode EOWMode, -- co or contra
|
|
rsTTPE1SrcPointer INTEGER, -- Order Wire: index in x21Src
|
|
rsTTPF1SrcPointer INTEGER, -- User Chanel: not used
|
|
rsTTPEOWByteLine INTEGER,
|
|
rsTTPEOWByteColumn INTEGER,
|
|
rsTTPSesThreshold INTEGER,
|
|
rsTTPLof Severity
|
|
}
|
|
|
|
rsTTPIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular
|
|
synchronous physical interface.
|
|
The value of this index is always the same as spiTTPIndex.
|
|
"
|
|
::= { rsTTPEntry 1 }
|
|
|
|
rsTTPMonitor OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the value of this field is set to false, the failure detection
|
|
is stopped for this regenerator section terminaison."
|
|
::= { rsTTPEntry 2 }
|
|
|
|
rsTTPName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string which identifies the particular entry among the
|
|
regenerator section terminaison entries. "
|
|
::= { rsTTPEntry 3 }
|
|
|
|
rsTTPFailure OBJECT-TYPE
|
|
SYNTAX RsTTPFailure
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active failures on regenerator section terminaison"
|
|
::= { rsTTPEntry 4 }
|
|
|
|
rsTTPSeverity OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed active Failure for regenerator section terminaison."
|
|
::= { rsTTPEntry 5 }
|
|
|
|
rsTTPEOWMode OBJECT-TYPE
|
|
SYNTAX EOWMode
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mode used for EOW: Codir or contradir Master"
|
|
::= { rsTTPEntry 8 }
|
|
|
|
rsTTPE1SrcPointer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to
|
|
E1 RSOH byte (index in X21 table)
|
|
Usualy E1 carries X21 EOW (engineering order wire) data
|
|
and thus the pointer s value reference a mib X21 port entry.
|
|
Zero indicates not used"
|
|
::= { rsTTPEntry 9 }
|
|
|
|
rsTTPF1SrcPointer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to
|
|
F1 RSOH byte.Zero indicates not used"
|
|
::= { rsTTPEntry 10 }
|
|
|
|
rsTTPSesThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of errors above which the second is declared
|
|
severely errored for this interface/function.
|
|
This value apply for near and far interface/function
|
|
"
|
|
::= { rsTTPEntry 11 }
|
|
|
|
rsTTPEOWByteLine OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The line determines the SOH byte selected for Engineering
|
|
Order Wire: SOH starts with 3 lines of RSOH (1,2,3) and
|
|
finish with 5 lines of MSOH (5,6,7,8,9)
|
|
E1 is on line 2 column 4.
|
|
Zero indicates EOW not used, value different from 2 means EOW
|
|
not on E1"
|
|
::= { rsTTPEntry 12 }
|
|
|
|
rsTTPEOWByteColumn OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The column determines the SOH byte selected for Engineering
|
|
Order Wire: SOH is composed of Col [1,9]
|
|
E1 is on line 2 column 4.
|
|
Zero indicates EOW not used, value different from 4 means EOW
|
|
not on E1"
|
|
::= { rsTTPEntry 13 }
|
|
|
|
rsTTPLof OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Loss Of Frame failure
|
|
for regenerator section terminaison."
|
|
::= { rsTTPEntry 20 }
|
|
-- End of regenerator section terminaison description
|
|
|
|
--*******************************************************************
|
|
--* multiplex section terminaison (mst)
|
|
--*******************************************************************
|
|
ProtectionType ::= INTEGER
|
|
{
|
|
none(0),
|
|
msp(1),
|
|
msSPRing(2)
|
|
}
|
|
|
|
MsTTPFailure ::= INTEGER
|
|
{
|
|
none(0),
|
|
ais(1),
|
|
eber(2),
|
|
sd(4),
|
|
sdRdi(12),
|
|
rdi(8)
|
|
}
|
|
|
|
msTTPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MsTTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of multiplex section terminaison in equipment."
|
|
::= { msTTP 2 }
|
|
|
|
msTTPEntry OBJECT-TYPE
|
|
SYNTAX MsTTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular multiplex section terminaison of the equipment."
|
|
INDEX { msTTPIndex }
|
|
::= { msTTPTable 1 }
|
|
|
|
MsTTPEntry ::= SEQUENCE
|
|
{
|
|
msTTPIndex INTEGER, -- spi Index
|
|
msTTPProtectionType ProtectionType,
|
|
msTTPMonitor SagemBoolean,
|
|
msTTPName DisplayString,
|
|
msTTPFailure MsTTPFailure,
|
|
msTTPSeverity Severity,
|
|
msTTPEOWMode EOWMode, -- co or contra
|
|
msTTPE2SrcPointer INTEGER, -- Order Wire: index in x21Src
|
|
msTTPMonEber SagemBoolean,
|
|
msTTPEOWByteLine INTEGER,
|
|
msTTPEOWByteColumn INTEGER,
|
|
msTTPSdThreshold INTEGER,
|
|
msTTPSesThreshold INTEGER,
|
|
msTTPEber Severity,
|
|
msTTPSd Severity,
|
|
msTTPRdi Severity
|
|
}
|
|
|
|
msTTPIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular
|
|
synchronous physical interface.
|
|
The value of this index is always the same as spiTTPIndex"
|
|
::= { msTTPEntry 1 }
|
|
|
|
msTTPProtectionType OBJECT-TYPE
|
|
SYNTAX ProtectionType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this field indicates the kind of wanted multiplex section protection.
|
|
The default value is NONE.
|
|
if value is changed in msp(1) or msSPRing(2) then (if it's possible) an entry is created
|
|
respectivelly in mspTable or msSPRingTable. But these tables have to be completed to obtain
|
|
a configured protection.
|
|
If value is changed in None(0)then the associated entry in mspTable or msSPRingTable is deleted
|
|
(if it's possible)."
|
|
::= { msTTPEntry 2 }
|
|
|
|
msTTPMonitor OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the value of this field is set to false, the failure detection
|
|
is stopped for this multiplex section terminaison."
|
|
::= { msTTPEntry 3 }
|
|
|
|
msTTPName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string which identifies the particular entry among the
|
|
multiplex section terminaison entries. "
|
|
::= { msTTPEntry 4 }
|
|
|
|
msTTPFailure OBJECT-TYPE
|
|
SYNTAX MsTTPFailure
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active failures on multiplex section terminaison"
|
|
::= { msTTPEntry 5 }
|
|
|
|
msTTPSeverity OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with active failures on multiplex section terminaison."
|
|
::= { msTTPEntry 6 }
|
|
|
|
msTTPEOWMode OBJECT-TYPE
|
|
SYNTAX EOWMode
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mode used for EOW: Codir or contradir Master"
|
|
::= { msTTPEntry 7 }
|
|
|
|
msTTPE2SrcPointer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to
|
|
E2 MSOH byte.
|
|
Usualy E2 carries X21 EOW (engineering order wire) data.
|
|
The reference is an index in X21 table.Zero indicates not used"
|
|
::= { msTTPEntry 8 }
|
|
|
|
msTTPEOWByteLine OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The line determines the SOH byte selected for Engineering
|
|
Order Wire: SOH starts with 3 lines of RSOH (1,2,3) and
|
|
finish with 5 lines of MSOH (5,6,7,8,9)
|
|
E2 is on line 9 column 7.
|
|
Zero indicates not used, value different from 9 means EOW
|
|
not on E2"
|
|
::= { msTTPEntry 9 }
|
|
|
|
msTTPEOWByteColumn OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The column determines the SOH byte selected for Engineering
|
|
Order Wire: SOH is composed of Col [1,9]
|
|
E2 is on line 9 column 7.
|
|
Zero indicates EOW not used, value different from 7 means EOW
|
|
not on E2"
|
|
::= { msTTPEntry 10 }
|
|
|
|
msTTPMonEber OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the value of this field is true, the eber is monitored and is used as
|
|
MSP and SETS criterium.
|
|
If this defect is detected, an ais signal is send downstream and
|
|
rdi upstream."
|
|
::= { msTTPEntry 11 }
|
|
|
|
msTTPSdThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Signal Degrade failure is declared if the error block rate is
|
|
greater than 1E(-mstSdThreshold).
|
|
The Signal Degrade failure desapeared when the error block rate is
|
|
less than 1E(1 - mstSdThreshold)."
|
|
::= { msTTPEntry 12 }
|
|
|
|
msTTPSesThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of errors above which the second is declared
|
|
severely errored for this interface/function.
|
|
This value apply for near and far interface/function"
|
|
::= { msTTPEntry 13 }
|
|
|
|
msTTPEber OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Excecive Bit Error Rate failure
|
|
for multiplex section terminaison."
|
|
::= { msTTPEntry 20 }
|
|
|
|
msTTPSd OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Signal Degrade failure
|
|
for multiplex section terminaison."
|
|
::= { msTTPEntry 21 }
|
|
|
|
msTTPRdi OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Remote Defect Indication failure
|
|
for multiplex section terminaison."
|
|
::= { msTTPEntry 22 }
|
|
-- End of multiplex section terminaison description
|
|
|
|
|
|
--*******************************************************************
|
|
--* multiplex section adaptation (msa)
|
|
--*
|
|
--* This part allow to know all the VC4 provided by the current boards
|
|
--* of the equipment. There is no relation with the configured connections
|
|
--*******************************************************************
|
|
|
|
MsaSrcType ::= INTEGER
|
|
{
|
|
none(0),
|
|
msa(1),
|
|
vc4(2)
|
|
}
|
|
|
|
MsaSinkType ::= INTEGER
|
|
{
|
|
msa(0),
|
|
mst(1)
|
|
}
|
|
|
|
msaTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MsaEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of multiplex section adaptation in equipment."
|
|
::= { msa 2 }
|
|
|
|
msaEntry OBJECT-TYPE
|
|
SYNTAX MsaEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular multiplex section adaptation of the equipment."
|
|
INDEX { msaIndex }
|
|
::= { msaTable 1 }
|
|
|
|
MsaEntry ::= SEQUENCE
|
|
{
|
|
msaIndex INTEGER, -- spiTTPIndex if msaSinkType = mst
|
|
msaSTMLevel STMLevel,
|
|
msaSinkType MsaSinkType, -- msa or mst
|
|
msaSinkPointer INTEGER, -- index in msa (msaIndex) or mst (spiTTPIndex)
|
|
msaName DisplayString,
|
|
msaSrc1Type MsaSrcType, --msa or vc4
|
|
msaSrc2Type MsaSrcType, --msa or vc4
|
|
msaSrc3Type MsaSrcType, --msa or vc4
|
|
msaSrc4Type MsaSrcType, --msa or vc4
|
|
msaSrc1Pointer INTEGER, -- index in msa (msaIndex) or mst (vc4Index)
|
|
msaSrc2Pointer INTEGER, -- index in msa (msaIndex) or mst (vc4Index), or 0
|
|
msaSrc3Pointer INTEGER, -- index in msa (msaIndex) or mst (vc4Index), or 0
|
|
msaSrc4Pointer INTEGER -- index in msa (msaIndex) or mst (vc4Index), or 0
|
|
}
|
|
|
|
msaIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of a particular entry among the
|
|
multiplex section adaptation entries. "
|
|
::= { msaEntry 1 }
|
|
|
|
msaSTMLevel OBJECT-TYPE
|
|
SYNTAX STMLevel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The STM-n level of the multiplex section adaptation."
|
|
::= { msaEntry 2 }
|
|
|
|
msaSinkType OBJECT-TYPE
|
|
SYNTAX MsaSinkType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Type of msa sinkPointer: msa or mst"
|
|
::= { msaEntry 3 }
|
|
|
|
msaSinkPointer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to this
|
|
function on synchronous port interface side.
|
|
In most equipments, this value cannot be changed and points to
|
|
the MST it is hard wired with."
|
|
::= { msaEntry 4 }
|
|
|
|
msaName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string which identifies the particular entry among the
|
|
multiplex section adaptation entries. "
|
|
::= { msaEntry 5 }
|
|
|
|
msaSrc1Type OBJECT-TYPE
|
|
SYNTAX MsaSrcType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of msa srcPointer: msa or vc4"
|
|
::= { msaEntry 6 }
|
|
|
|
msaSrc2Type OBJECT-TYPE
|
|
SYNTAX MsaSrcType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of msa srcPointer: msa or vc4"
|
|
::= { msaEntry 7 }
|
|
|
|
msaSrc3Type OBJECT-TYPE
|
|
SYNTAX MsaSrcType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of msa srcPointer: msa or vc4"
|
|
::= { msaEntry 8 }
|
|
|
|
msaSrc4Type OBJECT-TYPE
|
|
SYNTAX MsaSrcType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of msa srcPointer: msa or vc4"
|
|
::= { msaEntry 9 }
|
|
|
|
msaSrc1Pointer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table index of the object which sends the data flow to this
|
|
function on equipment side.
|
|
For STM16: 4 pseudo STM4 (group of 4STM1) identified by their
|
|
index in msaTable. Theses indexes must be differents to thoses
|
|
used by the MST Table.
|
|
For STM4: 4 VC4 identified by their index in vc4Table
|
|
For STM1: 1 VC4 identified by its index in vc4Table
|
|
"
|
|
::= { msaEntry 10 }
|
|
|
|
msaSrc2Pointer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to this
|
|
function on equipment side.
|
|
In most equipments, this value cannot be changed and points to
|
|
the VC4 function it is hard wired with."
|
|
::= { msaEntry 11 }
|
|
|
|
msaSrc3Pointer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to this
|
|
function on equipment side.
|
|
In most equipments, this value cannot be changed and points to
|
|
the VC4 function it is hard wired with."
|
|
::= { msaEntry 12 }
|
|
|
|
msaSrc4Pointer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to this
|
|
function on equipment side.
|
|
In most equipments, this value cannot be changed and points to
|
|
the VC4 function it is hard wired with."
|
|
::= { msaEntry 13 }
|
|
-- End of multiplex section adaptation description
|
|
|
|
|
|
--*******************************************************************
|
|
--* Common Types
|
|
--*******************************************************************
|
|
|
|
CTPStatus ::= INTEGER
|
|
{
|
|
free (0),
|
|
used (1)
|
|
}
|
|
|
|
|
|
--*******************************************************************
|
|
--* CTP administrative unit order 4 (au4)
|
|
--*******************************************************************
|
|
Au4CTPFailure ::= INTEGER
|
|
{
|
|
none(0),ais(1),lop(2),lom(3)
|
|
}
|
|
|
|
Au4CTPCnxType ::= INTEGER
|
|
{
|
|
none(0),au(1),au4c(4),au16c(16),tu(20)
|
|
}
|
|
|
|
au4CTPNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of administrative unit order 4 in equipment."
|
|
::= { au4CTP 1 }
|
|
|
|
au4CTPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Au4CTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of administrative unit order 4 in equipment which are availables for new connection or
|
|
used in connection. In that case, an indication on the connection type is set
|
|
into the au4CTPCnxType Variable.
|
|
All au4 CTP, which are made up of lower connection level (tu3 or tu12), are set to 'used' value with
|
|
'tu' type connection indication ."
|
|
::= { au4CTP 2 }
|
|
|
|
au4CTPEntry OBJECT-TYPE
|
|
SYNTAX Au4CTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular administrative unit order 4 of the equipment."
|
|
INDEX { au4CTPIndex }
|
|
::= { au4CTPTable 1 }
|
|
|
|
Au4CTPEntry ::= SEQUENCE
|
|
{
|
|
au4CTPIndex INTEGER,
|
|
au4CTPStatus CTPStatus, -- free or used
|
|
au4CTPCnxType Au4CTPCnxType, -- depends on the connection type (none if no connection)
|
|
au4CTPName DisplayString,
|
|
au4CTPMonitor SagemBoolean,
|
|
au4CTPFailure Au4CTPFailure,
|
|
au4CTPSeverity Severity,
|
|
au4CTPAis Severity,
|
|
au4CTPLop Severity,
|
|
au4CTPLom Severity
|
|
}
|
|
|
|
au4CTPIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular
|
|
administrative unit order 4.
|
|
The value of index is a constant assigned to an entry at
|
|
equipment design time. It is usualy related to harware."
|
|
::= { au4CTPEntry 1 }
|
|
|
|
au4CTPStatus OBJECT-TYPE
|
|
SYNTAX CTPStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"au4 connection point Status: free or used.
|
|
The 'free' value is used when there is no connection with this output CTP"
|
|
::= { au4CTPEntry 2 }
|
|
|
|
au4CTPCnxType OBJECT-TYPE
|
|
SYNTAX Au4CTPCnxType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"au4 connection Type: none, au4, au4-4c,au4-16c,tu.
|
|
The 'none' value is used when there is no connection with this output CTP"
|
|
::= { au4CTPEntry 3 }
|
|
|
|
au4CTPName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string which identifies the particular entry among the
|
|
administrative unit order 4 entries. "
|
|
::= { au4CTPEntry 4 }
|
|
|
|
au4CTPMonitor OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the value of this field is set to false, the failure detection
|
|
is stopped for this administrative unit order 4."
|
|
::= { au4CTPEntry 6 }
|
|
|
|
au4CTPFailure OBJECT-TYPE
|
|
SYNTAX Au4CTPFailure
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active failures on administrative unit order 4"
|
|
::= { au4CTPEntry 7 }
|
|
|
|
au4CTPSeverity OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to failure severity for administrative unit order 4."
|
|
::= { au4CTPEntry 8 }
|
|
|
|
au4CTPAis OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Alarme Indication Signal failure
|
|
for administrative unit order 4."
|
|
::= { au4CTPEntry 20 }
|
|
|
|
au4CTPLop OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Loss Of Pointer failure
|
|
for administrative unit order 4."
|
|
::= { au4CTPEntry 21 }
|
|
|
|
au4CTPLom OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Loss Of MultiFrame failure
|
|
for administrative unit order 4."
|
|
::= { au4CTPEntry 22 }
|
|
|
|
-- End of administrative unit order 4 description
|
|
|
|
|
|
|
|
--*******************************************************************
|
|
--* TTP virtual container order 4 (vc4-ttp)
|
|
--*******************************************************************
|
|
Vc4TTPSinkType ::= INTEGER
|
|
{
|
|
mst (1),
|
|
nspi (2)
|
|
}
|
|
|
|
Vc4TTPTraceMode ::= INTEGER
|
|
{
|
|
size1 (1),
|
|
size16 (16)
|
|
}
|
|
|
|
Vc4TTPSignalLabel ::= INTEGER
|
|
{
|
|
unequiped(0), unspecified(1), tug(2), all1(255)
|
|
}
|
|
|
|
Vc4TTPFailure ::= INTEGER
|
|
{
|
|
none (0),rdi (1), sd (2), sdRdi (3),
|
|
uneq (4),uneqSd (6),plm (8), plmRdi (9), plmSd (10),
|
|
plmRdiSd(11),tim (16), timRdi(17), timSd (18),
|
|
timRdiSd(19)
|
|
}
|
|
|
|
|
|
vc4TTPNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of virtual container order 4 in equipment."
|
|
::= { vc4TTP 1 }
|
|
|
|
vc4TTPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Vc4TTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of virtual container order 4 in equipment.The number of records depends on the kinds of
|
|
configured boards"
|
|
::= { vc4TTP 2 }
|
|
|
|
vc4TTPEntry OBJECT-TYPE
|
|
SYNTAX Vc4TTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular virtual container order 4 of the equipment."
|
|
INDEX { vc4TTPIndex }
|
|
::= { vc4TTPTable 1 }
|
|
|
|
|
|
Vc4TTPEntry ::= SEQUENCE
|
|
{
|
|
vc4TTPIndex INTEGER,
|
|
vc4TTPSinkPointer INTEGER, -- MSTindex or nspiTTPindex
|
|
vc4TTPSinkType Vc4TTPSinkType, -- MST or nspi
|
|
vc4TTPName DisplayString,
|
|
vc4TTPMonitor SagemBoolean,
|
|
vc4TTPFailure Vc4TTPFailure,
|
|
vc4TTPSeverity Severity,
|
|
vc4TTPTraceMode Vc4TTPTraceMode,
|
|
vc4TTPPathTraceExpected OCTET STRING (SIZE (16)),
|
|
vc4TTPPathTraceSent OCTET STRING (SIZE (16)),
|
|
vc4TTPPathTraceReceived OCTET STRING (SIZE (16)),
|
|
vc4TTPLabelExpected Vc4TTPSignalLabel,
|
|
vc4TTPLabelSent Vc4TTPSignalLabel,
|
|
vc4TTPLabelReceived Vc4TTPSignalLabel,
|
|
vc4TTPSdThreshold INTEGER,
|
|
vc4TTPSesThreshold INTEGER,
|
|
vc4TTPBidirectionnal SagemBoolean,
|
|
vc4TTPRdi Severity,
|
|
vc4TTPSd Severity,
|
|
vc4TTPUneq Severity,
|
|
vc4TTPPlm Severity,
|
|
vc4TTPTimDis SagemBoolean,
|
|
vc4TTPTim Severity
|
|
}
|
|
|
|
vc4TTPIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular
|
|
virtual container order 4.
|
|
The value of index is a constant assigned to an entry at
|
|
equipment design time. It is usualy related to harware."
|
|
::= { vc4TTPEntry 1 }
|
|
|
|
vc4TTPSinkPointer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to this
|
|
function on synchronous or unsynchronous port interface side.
|
|
This pointer corresponds to an index in the msTTPTable or nspiTTPTable."
|
|
::= { vc4TTPEntry 2 }
|
|
|
|
vc4TTPSinkType OBJECT-TYPE
|
|
SYNTAX Vc4TTPSinkType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the kind of the sink Pointer"
|
|
::= { vc4TTPEntry 3 }
|
|
|
|
vc4TTPName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string which identifies the particular entry among the
|
|
virtual container order 4 entries. "
|
|
::= { vc4TTPEntry 5 }
|
|
|
|
vc4TTPMonitor OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the value of this field is set to false, the failure detection
|
|
is stopped for this virtual container order 4."
|
|
::= { vc4TTPEntry 6 }
|
|
|
|
vc4TTPFailure OBJECT-TYPE
|
|
SYNTAX Vc4TTPFailure
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active failures on virtual container order 4"
|
|
::= { vc4TTPEntry 7 }
|
|
|
|
vc4TTPSeverity OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to failure severity for virtual container order 4."
|
|
::= { vc4TTPEntry 8 }
|
|
|
|
vc4TTPTraceMode OBJECT-TYPE
|
|
SYNTAX Vc4TTPTraceMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration of the pathTrace length (1 byte or 16 bytes)."
|
|
::= { vc4TTPEntry 9 }
|
|
|
|
vc4TTPPathTraceExpected OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The path trace is a user string that always follows the vc4.
|
|
If the value the received path trace does not match this one, a
|
|
tim (Trail Identifier Mismatch) failure is issued.
|
|
The value `? ' match all possible received path trace."
|
|
::= { vc4TTPEntry 11 }
|
|
|
|
vc4TTPPathTraceSent OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The path trace is a user string that always follows the vc4.
|
|
The value of this field is sent in j1 byte as path trace for this vc4.
|
|
The default value is `all 0'."
|
|
::= { vc4TTPEntry 12 }
|
|
|
|
vc4TTPPathTraceReceived OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The path trace is a user string that always follows the vc4.
|
|
The value is the actual path trace received in j1 byte"
|
|
::= { vc4TTPEntry 13 }
|
|
|
|
vc4TTPLabelExpected OBJECT-TYPE
|
|
SYNTAX Vc4TTPSignalLabel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The signal label indicates the multiplexing structure of the vc4.
|
|
If the signal label received for this vc4 is not null and does
|
|
not match this field, a Signal Label Mismatch failure is detected.
|
|
If the received label is null a virtual container UNEQuiped
|
|
failure is detected."
|
|
::= { vc4TTPEntry 14 }
|
|
|
|
vc4TTPLabelSent OBJECT-TYPE
|
|
SYNTAX Vc4TTPSignalLabel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The signal label indicates the multiplexing structure of the vc4.
|
|
The value of this field in sent as signal label for the vc4."
|
|
::= { vc4TTPEntry 15 }
|
|
|
|
vc4TTPLabelReceived OBJECT-TYPE
|
|
SYNTAX Vc4TTPSignalLabel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The signal label indicates the multiplexing structure of the vc4.
|
|
The value of this field is the actual received signal label
|
|
for this vc4"
|
|
::= { vc4TTPEntry 16 }
|
|
|
|
vc4TTPSdThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Signal Degrade failure is declared if the error block rate is
|
|
greater than 1E(-SdThreshold).
|
|
The Signal Degrade failure desapeared when the error block rate is
|
|
less than 1E(1 - SdThreshold)."
|
|
::= { vc4TTPEntry 17 }
|
|
|
|
vc4TTPSesThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of errors above which the second is declared
|
|
severely errored for this interface/function.
|
|
This value apply for near and far interface/function"
|
|
::= { vc4TTPEntry 18 }
|
|
|
|
vc4TTPBidirectionnal OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If set to false the equipment does not send Remote Defect Indication."
|
|
::= { vc4TTPEntry 19 }
|
|
|
|
vc4TTPRdi OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Remote Defect Indication failure
|
|
for virtual container order 4."
|
|
::= { vc4TTPEntry 20 }
|
|
|
|
vc4TTPSd OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Signal Degrade failure
|
|
for virtual container order 4."
|
|
::= { vc4TTPEntry 21 }
|
|
|
|
vc4TTPUneq OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with virtual container UNEQuiped failure
|
|
for virtual container order 4."
|
|
::= { vc4TTPEntry 22 }
|
|
|
|
vc4TTPPlm OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Path Label Mismatch failure
|
|
for virtual container order 4."
|
|
::= { vc4TTPEntry 23 }
|
|
|
|
vc4TTPTimDis OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If set to true the equipment does not manage the Tim Failure."
|
|
::= { vc4TTPEntry 24 }
|
|
|
|
vc4TTPTim OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Trail Identifier Mismatch failure
|
|
for virtual container order 4."
|
|
::= { vc4TTPEntry 25 }
|
|
-- End of virtual container order 4 description
|
|
|
|
|
|
|
|
--*******************************************************************
|
|
--* CTP tributary unit 3 (tu3)
|
|
--*******************************************************************
|
|
|
|
Tu3CTPFailure ::= INTEGER
|
|
{
|
|
none (0),
|
|
ais (1),
|
|
lop (2)
|
|
}
|
|
|
|
tu3CTPNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of tributary unit in equipment."
|
|
::= { tu3CTP 1 }
|
|
|
|
tu3CTPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Tu3CTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of tributary units order 3 in equipment which are availables for new connection or used in
|
|
the same connection level. In that case, an indication on the connection point status is set into the
|
|
tu3CTPStatus Variable.
|
|
All tu3 CTP, which are involved in different connection level (tu12 or au4), disappear from
|
|
this List."
|
|
::= { tu3CTP 2 }
|
|
|
|
tu3CTPEntry OBJECT-TYPE
|
|
SYNTAX Tu3CTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular tributary unit of the equipment."
|
|
INDEX { tu3CTPIndex}
|
|
::= { tu3CTPTable 1 }
|
|
|
|
Tu3CTPEntry ::= SEQUENCE
|
|
{
|
|
tu3CTPIndex INTEGER,
|
|
tu3CTPStatus CTPStatus, -- free or used
|
|
tu3CTPName DisplayString,
|
|
tu3CTPMonitor SagemBoolean,
|
|
tu3CTPFailure Tu3CTPFailure,
|
|
tu3CTPSeverity Severity,
|
|
tu3CTPAis Severity,
|
|
tu3CTPLop Severity
|
|
}
|
|
|
|
tu3CTPIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index that identifies the particular entry among the
|
|
tributary unit entries. "
|
|
::= { tu3CTPEntry 1 }
|
|
|
|
tu3CTPStatus OBJECT-TYPE
|
|
SYNTAX CTPStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tu3 connection point Status: free or used.
|
|
The 'free' value is used when there is no connection with this output CTP"
|
|
::= { tu3CTPEntry 2 }
|
|
|
|
tu3CTPName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string which identifies the particular entry among the
|
|
tributary unit entries. "
|
|
::= { tu3CTPEntry 5 }
|
|
|
|
tu3CTPMonitor OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the value of this field is set to false, the failure detection
|
|
is stopped for this tributary unit."
|
|
::= { tu3CTPEntry 6 }
|
|
|
|
tu3CTPFailure OBJECT-TYPE
|
|
SYNTAX Tu3CTPFailure
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active failures on tributary unit"
|
|
::= { tu3CTPEntry 7 }
|
|
|
|
tu3CTPSeverity OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to failure severity for tributary unit."
|
|
::= { tu3CTPEntry 8 }
|
|
|
|
tu3CTPAis OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Alarme Indication Signal failure
|
|
for tributary unit."
|
|
::= { tu3CTPEntry 20 }
|
|
|
|
tu3CTPLop OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Loss Of Pointer failure
|
|
for tributary unit."
|
|
::= { tu3CTPEntry 21 }
|
|
-- End of tributary unit description
|
|
|
|
--*******************************************************************
|
|
--* CTP tributary unit 12 (tu12)
|
|
--*******************************************************************
|
|
|
|
Tu12CTPFailure ::= INTEGER
|
|
{
|
|
none (0),
|
|
ais (1),
|
|
lop (2)
|
|
}
|
|
|
|
tu12CTPNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of tributary unit in equipment."
|
|
::= { tu12CTP 1 }
|
|
|
|
tu12CTPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Tu12CTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of tributary unit order 12 in equipment which are availables for new connection or
|
|
used in the same connection level. In that case, an indication on the connection point Status
|
|
is set into the tu12CTPStatus Variable.
|
|
All tu12 CTP, which are involved in a different connection level (tu3 or au4), disappear from
|
|
this List."
|
|
::= { tu12CTP 2 }
|
|
|
|
tu12CTPEntry OBJECT-TYPE
|
|
SYNTAX Tu12CTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular tributary unit of the equipment."
|
|
INDEX { tu12CTPIndex }
|
|
::= { tu12CTPTable 1 }
|
|
|
|
Tu12CTPEntry ::= SEQUENCE
|
|
{
|
|
tu12CTPIndex INTEGER,
|
|
tu12CTPStatus CTPStatus, -- free or used
|
|
tu12CTPName DisplayString,
|
|
tu12CTPMonitor SagemBoolean,
|
|
tu12CTPFailure Tu12CTPFailure,
|
|
tu12CTPSeverity Severity,
|
|
tu12CTPAis Severity,
|
|
tu12CTPLop Severity
|
|
}
|
|
|
|
tu12CTPIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular tu12."
|
|
::= { tu12CTPEntry 1 }
|
|
|
|
tu12CTPStatus OBJECT-TYPE
|
|
SYNTAX CTPStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tu12 connection point Status: free or used.
|
|
The 'free' value is used when there is no connection with this output CTP"
|
|
::= { tu12CTPEntry 2 }
|
|
|
|
tu12CTPName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string which identifies the particular entry among the
|
|
tributary unit entries. "
|
|
::= { tu12CTPEntry 5 }
|
|
|
|
tu12CTPMonitor OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the value of this field is set to false, the failure detection
|
|
is stopped for this tributary unit."
|
|
::= { tu12CTPEntry 6 }
|
|
|
|
tu12CTPFailure OBJECT-TYPE
|
|
SYNTAX Tu12CTPFailure
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active failures on tributary unit"
|
|
::= { tu12CTPEntry 7 }
|
|
|
|
tu12CTPSeverity OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to failure severity for tributary unit."
|
|
::= { tu12CTPEntry 8 }
|
|
|
|
tu12CTPAis OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Alarme Indication Signal failure
|
|
for tributary unit."
|
|
::= { tu12CTPEntry 20 }
|
|
|
|
tu12CTPLop OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Loss Of Pointer failure
|
|
for tributary unit."
|
|
::= { tu12CTPEntry 21 }
|
|
|
|
-- End of tributary unit description
|
|
|
|
--*******************************************************************
|
|
--* virtual container order 3 (vc3)
|
|
--*******************************************************************
|
|
Vc3TTPSinkType ::= INTEGER
|
|
{
|
|
vc4 (1),
|
|
nspi (2)
|
|
}
|
|
|
|
Vc3TTPSignalLabel ::= INTEGER
|
|
{
|
|
unequiped(0), unspecified(1),
|
|
mapping3445(4), all1(7)
|
|
}
|
|
|
|
VcLoFailure ::= INTEGER
|
|
{
|
|
none (0),
|
|
rdi (1),
|
|
sd (2), sdRdi (3),
|
|
uneq (4), uneqSd (6),
|
|
plm (8), plmRdi (9), plmSd (10), plmRdiSd(11),
|
|
tim (16), timRdi(17), timSd (18), timRdiSd(19)
|
|
}
|
|
|
|
vc3TTPNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of virtual container order 3 in equipment."
|
|
::= { vc3TTP 1 }
|
|
|
|
vc3TTPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Vc3TTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of virtual container order 3 in equipment.The number of records depends on the kinds of
|
|
configured boards"
|
|
::= { vc3TTP 2 }
|
|
|
|
vc3TTPEntry OBJECT-TYPE
|
|
SYNTAX Vc3TTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular virtual container order 3 of the equipment."
|
|
INDEX { vc3TTPIndex }
|
|
::= { vc3TTPTable 1 }
|
|
|
|
|
|
Vc3TTPEntry ::= SEQUENCE
|
|
{
|
|
vc3TTPIndex INTEGER,
|
|
vc3TTPSinkPointer INTEGER, -- nspiTTPIndex or VC4index
|
|
vc3TTPSinkType Vc3TTPSinkType, -- Nspi or VC4
|
|
vc3TTPName DisplayString,
|
|
vc3TTPMonitor SagemBoolean,
|
|
vc3TTPFailure VcLoFailure,
|
|
vc3TTPSeverity Severity,
|
|
vc3TTPPathTraceExpected OCTET STRING,
|
|
vc3TTPPathTraceSent OCTET STRING,
|
|
vc3TTPPathTraceReceived OCTET STRING,
|
|
vc3TTPLabelExpected Vc3TTPSignalLabel,
|
|
vc3TTPLabelSent Vc3TTPSignalLabel,
|
|
vc3TTPLabelReceived Vc3TTPSignalLabel,
|
|
vc3TTPSdThreshold INTEGER,
|
|
vc3TTPSesThreshold INTEGER,
|
|
vc3TTPBidirectionnal SagemBoolean,
|
|
vc3TTPRdi Severity,
|
|
vc3TTPSd Severity,
|
|
vc3TTPUneq Severity,
|
|
vc3TTPPlm Severity,
|
|
vc3TTPTim Severity
|
|
}
|
|
|
|
|
|
vc3TTPIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular
|
|
virtual container order 3.
|
|
The value of index is a constant assigned to an entry at
|
|
equipment design time. It is usualy related to harware."
|
|
::= { vc3TTPEntry 1 }
|
|
|
|
vc3TTPSinkPointer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to this
|
|
function on non-sdh physical port side."
|
|
::= { vc3TTPEntry 2 }
|
|
|
|
vc3TTPSinkType OBJECT-TYPE
|
|
SYNTAX Vc3TTPSinkType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the kind of the sink Pointer"
|
|
::= { vc3TTPEntry 3 }
|
|
|
|
vc3TTPName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string which identifies the particular entry among the
|
|
virtual container order 3 entries. "
|
|
::= { vc3TTPEntry 5 }
|
|
|
|
vc3TTPMonitor OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the value of this field is set to false, the failure detection
|
|
is stopped for this virtual container order 3."
|
|
::= { vc3TTPEntry 6 }
|
|
|
|
vc3TTPFailure OBJECT-TYPE
|
|
SYNTAX VcLoFailure
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active failures on virtual container order 3"
|
|
::= { vc3TTPEntry 7 }
|
|
|
|
vc3TTPSeverity OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to failure severity for virtual container order 3."
|
|
::= { vc3TTPEntry 8 }
|
|
|
|
vc3TTPPathTraceExpected OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The path trace is a user string that always follows the vc3.
|
|
If the value the received path trace does not match this one, a
|
|
tim (Trail Identifier Mismatch) failure is issued.
|
|
The value `? ' match all possible received path trace."
|
|
::= { vc3TTPEntry 9 }
|
|
|
|
vc3TTPPathTraceSent OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..15))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The path trace is a user string that always follows the vc3.
|
|
The value of this field is sent in j1 byte as path trace for this vc3.
|
|
The default value is `all 0'."
|
|
::= { vc3TTPEntry 10 }
|
|
|
|
vc3TTPPathTraceReceived OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (15))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The path trace is a user string that always follows the vc3.
|
|
The value is the actual path trace received in j1 byte"
|
|
::= { vc3TTPEntry 11 }
|
|
|
|
vc3TTPLabelExpected OBJECT-TYPE
|
|
SYNTAX Vc3TTPSignalLabel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The signal label indicates the multiplexing structure of the vc3.
|
|
Usualy the value of this field cannot be modified as most equipment
|
|
use the asynchronous bit multiplexing.
|
|
For historical reasons the receipt of label `unspecified ' does not
|
|
produce a Signal Label Mismatch failure."
|
|
::= { vc3TTPEntry 12 }
|
|
|
|
vc3TTPLabelSent OBJECT-TYPE
|
|
SYNTAX Vc3TTPSignalLabel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The signal label indicates the multiplexing structure of the vc3.
|
|
The value of this field is sent as signal label for the vc3.
|
|
The unspecified value is used for compatibilty with old sdh
|
|
equipments.
|
|
The `unequiped' value actives low order unequiped generator (lug).
|
|
In this case all 1 signal is inserted down and up stream."
|
|
::= { vc3TTPEntry 13 }
|
|
|
|
vc3TTPLabelReceived OBJECT-TYPE
|
|
SYNTAX Vc3TTPSignalLabel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The signal label indicates the multiplexing structure of the vc3.
|
|
The value of this field is the actual received signal label
|
|
for this vc3"
|
|
::= { vc3TTPEntry 14 }
|
|
|
|
vc3TTPSdThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Signal Degrade failure is declared if the error block rate is
|
|
greater than 1E(-SdThreshold).
|
|
The Signal Degrade failure desapeared when the error block rate is
|
|
less than 1E(1 - SdThreshold)."
|
|
::= { vc3TTPEntry 15 }
|
|
|
|
vc3TTPSesThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of errors above which the second is declared
|
|
severely errored for this interface/function.
|
|
This value apply for near and far interface/function"
|
|
::= { vc3TTPEntry 16 }
|
|
|
|
vc3TTPBidirectionnal OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If set to false the equipment does not send Remote Defect Indication."
|
|
::= { vc3TTPEntry 17 }
|
|
|
|
vc3TTPRdi OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Remote Defect Indication failure
|
|
for virtual container order 3."
|
|
::= { vc3TTPEntry 20 }
|
|
|
|
vc3TTPSd OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Signal Degrade failure
|
|
for virtual container order 3."
|
|
::= { vc3TTPEntry 21 }
|
|
|
|
vc3TTPUneq OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with virtual container UNEQuiped failure
|
|
for virtual container order 3."
|
|
::= { vc3TTPEntry 22 }
|
|
|
|
vc3TTPPlm OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Path Label Mismatch failure
|
|
for virtual container order 3."
|
|
::= { vc3TTPEntry 23 }
|
|
|
|
vc3TTPTim OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Trail Identifier Mismatch failure
|
|
for virtual container order 3."
|
|
::= { vc3TTPEntry 24 }
|
|
-- End of virtual container order 3 description
|
|
|
|
--*******************************************************************
|
|
--* virtual container order 12 (vc12)
|
|
--*******************************************************************
|
|
Vc12TTPSinkType ::= INTEGER
|
|
{
|
|
vc4 (1),
|
|
nspi (2)
|
|
}
|
|
|
|
Vc12TTPSignalLabel ::= INTEGER
|
|
{
|
|
unequiped(0), unspecified(1),
|
|
asyncBit(2), all1(7)
|
|
}
|
|
|
|
vc12TTPNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of virtual container order 12 in equipment."
|
|
::= { vc12TTP 1 }
|
|
|
|
vc12TTPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Vc12TTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of virtual container order 12 in equipment.The number of records depends on the kinds of
|
|
configured boards"
|
|
::= { vc12TTP 2 }
|
|
|
|
vc12TTPEntry OBJECT-TYPE
|
|
SYNTAX Vc12TTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular virtual container order 12 of the equipment."
|
|
INDEX { vc12TTPIndex }
|
|
::= { vc12TTPTable 1 }
|
|
|
|
|
|
Vc12TTPEntry ::= SEQUENCE
|
|
{
|
|
vc12TTPIndex INTEGER,
|
|
vc12TTPSinkPointer INTEGER, -- nspiTTPIndex or VC4index
|
|
vc12TTPSinkType Vc12TTPSinkType, -- Nspi or Vc4
|
|
vc12TTPName DisplayString,
|
|
vc12TTPMonitor SagemBoolean,
|
|
vc12TTPFailure VcLoFailure,
|
|
vc12TTPSeverity Severity,
|
|
vc12TTPPathTraceExpected OCTET STRING,
|
|
vc12TTPPathTraceSent OCTET STRING,
|
|
vc12TTPPathTraceReceived OCTET STRING,
|
|
vc12TTPLabelExpected Vc12TTPSignalLabel,
|
|
vc12TTPLabelSent Vc12TTPSignalLabel,
|
|
vc12TTPLabelReceived Vc12TTPSignalLabel,
|
|
vc12TTPSdThreshold INTEGER,
|
|
vc12TTPSesThreshold INTEGER,
|
|
vc12TTPBidirectionnal SagemBoolean,
|
|
vc12TTPRdi Severity,
|
|
vc12TTPSd Severity,
|
|
vc12TTPUneq Severity,
|
|
vc12TTPPlm Severity,
|
|
vc12TTPTim Severity
|
|
}
|
|
|
|
vc12TTPIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular
|
|
virtual container order 12.
|
|
The value of index is a constant assigned to an entry at
|
|
equipment design time. It is usualy related to harware."
|
|
::= { vc12TTPEntry 1 }
|
|
|
|
vc12TTPSinkPointer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to this
|
|
function on non-sdh physical port side."
|
|
::= { vc12TTPEntry 2 }
|
|
|
|
vc12TTPSinkType OBJECT-TYPE
|
|
SYNTAX Vc12TTPSinkType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the kind of the sink Pointer"
|
|
::= { vc12TTPEntry 3 }
|
|
|
|
vc12TTPName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string which identifies the particular entry among the
|
|
virtual container order 12 entries. "
|
|
::= { vc12TTPEntry 5 }
|
|
|
|
vc12TTPMonitor OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the value of this field is set to false, the failure detection
|
|
is stopped for this virtual container order 12."
|
|
::= { vc12TTPEntry 6 }
|
|
|
|
vc12TTPFailure OBJECT-TYPE
|
|
SYNTAX VcLoFailure
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active failures on virtual container order 12"
|
|
::= { vc12TTPEntry 7 }
|
|
|
|
vc12TTPSeverity OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to failure severity for virtual container order 12."
|
|
::= { vc12TTPEntry 8 }
|
|
|
|
|
|
vc12TTPPathTraceExpected OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The path trace is a user string that always follows the vc12.
|
|
If the value the received path trace does not match this one, a
|
|
tim (Trail Identifier Mismatch) failure is issued.
|
|
The value `? ' match all possible received path trace."
|
|
::= { vc12TTPEntry 9 }
|
|
|
|
vc12TTPPathTraceSent OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The path trace is a user string that always follows the vc12.
|
|
The value of this field is sent in j2 byte as path trace for this vc12.
|
|
The default value is `all 0'."
|
|
::= { vc12TTPEntry 10 }
|
|
|
|
vc12TTPPathTraceReceived OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The path trace is a user string that always follows the vc12.
|
|
The value is the actual path trace received in j2 byte"
|
|
::= { vc12TTPEntry 11 }
|
|
|
|
vc12TTPLabelExpected OBJECT-TYPE
|
|
SYNTAX Vc12TTPSignalLabel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The signal label indicates the multiplexing structure of the vc12.
|
|
Usualy the value of this field cannot be modified as most equipment
|
|
use the asynchronous bit multiplexing.
|
|
For historical reasons the receipt of label `unspecified ' does not
|
|
produce a Signal Label Mismatch failure."
|
|
::= { vc12TTPEntry 12 }
|
|
|
|
vc12TTPLabelSent OBJECT-TYPE
|
|
SYNTAX Vc12TTPSignalLabel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The signal label indicates the multiplexing structure of the vc12.
|
|
The value of this field is sent as signal label for the vc12.
|
|
The unspecified value is used for compatibilty with old sdh
|
|
equipments.
|
|
The `unequiped' value actives low order unequiped generator (lug).
|
|
In this case all 1 signal is inserted down and up stream."
|
|
::= { vc12TTPEntry 13 }
|
|
|
|
vc12TTPLabelReceived OBJECT-TYPE
|
|
SYNTAX Vc12TTPSignalLabel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The signal label indicates the multiplexing structure of the vc12.
|
|
The value of this field is the actual received signal label
|
|
for this vc12"
|
|
::= { vc12TTPEntry 14 }
|
|
|
|
vc12TTPSdThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Signal Degrade failure is declared if the error block rate is
|
|
greater than 1E(-SdThreshold).
|
|
The Signal Degrade failure desapeared when the error block rate is
|
|
less than 1E(1 - SdThreshold)."
|
|
::= { vc12TTPEntry 15 }
|
|
|
|
vc12TTPSesThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of errors above which the second is declared
|
|
severely errored for this interface/function.
|
|
This value apply for near and far interface/function"
|
|
::= { vc12TTPEntry 16 }
|
|
|
|
vc12TTPBidirectionnal OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If set to false the equipment does not send Remote Defect Indication."
|
|
::= { vc12TTPEntry 17 }
|
|
|
|
vc12TTPRdi OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Remote Defect Indication failure
|
|
for virtual container order 12."
|
|
::= { vc12TTPEntry 20 }
|
|
|
|
vc12TTPSd OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Signal Degrade failure
|
|
for virtual container order 12."
|
|
::= { vc12TTPEntry 21 }
|
|
|
|
vc12TTPUneq OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with virtual container UNEQuiped failure
|
|
for virtual container order 12."
|
|
::= { vc12TTPEntry 22 }
|
|
|
|
vc12TTPPlm OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Path Label Mismatch failure
|
|
for virtual container order 12."
|
|
::= { vc12TTPEntry 23 }
|
|
|
|
vc12TTPTim OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Trail Identifier Mismatch failure
|
|
for virtual container order 12."
|
|
::= { vc12TTPEntry 24 }
|
|
-- End of virtual container order 12 description
|
|
|
|
|
|
|
|
--*******************************************************************
|
|
--* non synchronous physical port (nspi)
|
|
--*******************************************************************
|
|
|
|
NspiSrcType ::= INTEGER
|
|
{
|
|
vc12 (1),
|
|
vc3 (2),
|
|
vc4 (3),
|
|
channel (4)
|
|
}
|
|
|
|
--*******************************************************************
|
|
--* Nspi CTP
|
|
--*******************************************************************
|
|
|
|
nspiCTPNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular non-sdh physical port.
|
|
The value of index is a constant assigned to an entry at
|
|
equipment design time. It is usualy related to harware."
|
|
::= { nspiCTP 1 }
|
|
|
|
nspiCTPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NspiCTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of non-sdh physical port in equipment."
|
|
::= { nspiCTP 2 }
|
|
|
|
nspiCTPEntry OBJECT-TYPE
|
|
SYNTAX NspiCTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular non-sdh physical port of the equipment."
|
|
INDEX { nspiCTPIndex }
|
|
::= { nspiCTPTable 1 }
|
|
|
|
|
|
NspiCTPEntry ::= SEQUENCE
|
|
{
|
|
nspiCTPIndex INTEGER,
|
|
nspiCTPTTPType NspiSrcType, -- VC3, VC12 or VC4
|
|
nspiCTPStatus CTPStatus, -- free or used
|
|
nspiCTPName DisplayString
|
|
}
|
|
|
|
nspiCTPIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular
|
|
non-sdh physical port.
|
|
The value of index is a constant assigned to an entry at
|
|
equipment design time. It is usualy related to harware."
|
|
::= { nspiCTPEntry 1 }
|
|
|
|
nspiCTPTTPType OBJECT-TYPE
|
|
SYNTAX NspiSrcType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of VC which is associated to the nspi interface."
|
|
::= { nspiCTPEntry 2 }
|
|
|
|
nspiCTPStatus OBJECT-TYPE
|
|
SYNTAX CTPStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"nspi connection point Status: free or used.
|
|
The 'free' value is used when there is no connection with this output CTP"
|
|
::= { nspiCTPEntry 3 }
|
|
|
|
nspiCTPName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string which identifies the particular entry among the
|
|
non-sdh physical port entries. "
|
|
::= { nspiCTPEntry 4 }
|
|
|
|
-- End of non-sdh physical port description
|
|
|
|
|
|
--*******************************************************************
|
|
--* Nspi TTP
|
|
--*******************************************************************
|
|
NspiTTPFailure ::= INTEGER
|
|
{
|
|
none (0),
|
|
los (1),
|
|
ais (2)
|
|
}
|
|
|
|
NspiTTPType ::= INTEGER
|
|
{
|
|
g703R75ohm (1),
|
|
g703R120ohm (2),
|
|
x21 (10),
|
|
ethernet (20),
|
|
atm (30)
|
|
}
|
|
|
|
NspiTTPLevel ::= INTEGER
|
|
{
|
|
rate2Mb (2),
|
|
rate10Mb (10),
|
|
rate34Mb (34),
|
|
rate45Mb (45),
|
|
rate100Mb (100),
|
|
rate140Mb (140),
|
|
rate1Gb (1000)
|
|
}
|
|
|
|
|
|
nspiTTPNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular non-sdh physical port.
|
|
The value of index is a constant assigned to an entry at
|
|
equipment design time. It is usualy related to harware."
|
|
::= { nspiTTP 1 }
|
|
|
|
nspiTTPTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NspiTTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of non-sdh physical port in equipment."
|
|
::= { nspiTTP 2 }
|
|
|
|
nspiTTPEntry OBJECT-TYPE
|
|
SYNTAX NspiTTPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular non-sdh physical port of the equipment."
|
|
INDEX { nspiTTPIndex }
|
|
::= { nspiTTPTable 1 }
|
|
|
|
NspiTTPEntry ::= SEQUENCE
|
|
{
|
|
nspiTTPIndex INTEGER,
|
|
nspiTTPType NspiTTPType,
|
|
nspiTTPLevel NspiTTPLevel,
|
|
nspiTTPName DisplayString,
|
|
nspiTTPBoardIndex INTEGER,
|
|
nspiTTPBoardAcces INTEGER,
|
|
nspiTTPSrcType NspiSrcType, -- VC3, VC12 or VC4
|
|
nspiTTPSrcPointer INTEGER, -- VC index
|
|
nspiTTPMonitor SagemBoolean,
|
|
nspiTTPFailure NspiTTPFailure,
|
|
nspiTTPSeverity Severity,
|
|
nspiTTPLoopback Loopback,
|
|
nspiTTPLos Severity,
|
|
nspiTTPAis Severity
|
|
}
|
|
|
|
nspiTTPIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular
|
|
non-sdh physical port.
|
|
The value of index is a constant assigned to an entry at
|
|
equipment design time. It is usualy related to harware."
|
|
::= { nspiTTPEntry 1 }
|
|
|
|
nspiTTPType OBJECT-TYPE
|
|
SYNTAX NspiTTPType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of media for the nspi interface."
|
|
::= { nspiTTPEntry 2 }
|
|
|
|
nspiTTPLevel OBJECT-TYPE
|
|
SYNTAX NspiTTPLevel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The rate level of the nspi interface."
|
|
::= { nspiTTPEntry 3 }
|
|
|
|
nspiTTPName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A text string which identifies the particular entry among the
|
|
non-sdh physical port entries. "
|
|
::= { nspiTTPEntry 4 }
|
|
|
|
nspiTTPBoardIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of the Board that supports the physical acces
|
|
of this interface"
|
|
::= { nspiTTPEntry 5 }
|
|
|
|
nspiTTPBoardAcces OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Friendly Index of the physical acces on the Board that supports
|
|
the interface"
|
|
::= { nspiTTPEntry 6 }
|
|
|
|
nspiTTPSrcType OBJECT-TYPE
|
|
SYNTAX NspiSrcType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the type of object which sends the data flow to this
|
|
interface. Usually the value is vc12, vc3 or vc4 types."
|
|
::= { nspiTTPEntry 7 }
|
|
|
|
nspiTTPSrcPointer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to this
|
|
interface. Usually the value is the Index of a vc12, vc3 or vc4."
|
|
::= { nspiTTPEntry 8 }
|
|
|
|
nspiTTPMonitor OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the value of this field is set to false, the failure detection
|
|
is stopped for this non-sdh physical port."
|
|
::= { nspiTTPEntry 9 }
|
|
|
|
nspiTTPFailure OBJECT-TYPE
|
|
SYNTAX NspiTTPFailure
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active failures on non-sdh physical port"
|
|
::= { nspiTTPEntry 10 }
|
|
|
|
nspiTTPSeverity OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to failure severity for non-sdh physical port."
|
|
::= { nspiTTPEntry 11 }
|
|
|
|
nspiTTPLoopback OBJECT-TYPE
|
|
SYNTAX Loopback
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This field gives the active loopback status on the
|
|
non-sdh physical port.
|
|
When its value is `line' the data flow recieved from the port side
|
|
is sent back to the line.
|
|
When its value is `equipment' the data flow recieved form equipment
|
|
side is send back.
|
|
The field can be set to a particular loopback value, even if there
|
|
no garantee that the loopback is really done. The real loopback status
|
|
of the interface must be checked in the response.
|
|
The loopback can be cleared by the equipment when it cannot remain
|
|
for any reason."
|
|
::= { nspiTTPEntry 14 }
|
|
|
|
nspiTTPLos OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Loss Of Signal failure
|
|
for non-sdh physical port."
|
|
::= { nspiTTPEntry 20 }
|
|
|
|
nspiTTPAis OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associed with Alarme Indication Signal failure
|
|
for non-sdh physical port."
|
|
::= { nspiTTPEntry 21 }
|
|
-- End of non-sdh physical port description
|
|
|
|
|
|
--*******************************************************************
|
|
--* Channel
|
|
--* This part allows to add a new decomposition level between nspi ports
|
|
--* and SDH Containers.
|
|
--*******************************************************************
|
|
ChannelEncaps ::= INTEGER
|
|
{
|
|
none (0),
|
|
atm (1),
|
|
pos (2),
|
|
gfp (3)
|
|
}
|
|
|
|
ChannelConcat ::= INTEGER
|
|
{
|
|
none (0),
|
|
virtual (1),
|
|
contiguous (2)
|
|
}
|
|
|
|
ChannelFailure ::= INTEGER
|
|
{
|
|
none (0),
|
|
loa (1),
|
|
lom (2),
|
|
sqm (3)
|
|
}
|
|
|
|
|
|
channelNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of SDH Channels in equipment."
|
|
::= { channel 1 }
|
|
|
|
channelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of SDH Channels in equipment."
|
|
::= { channel 2 }
|
|
|
|
channelEntry OBJECT-TYPE
|
|
SYNTAX ChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular SDH Channel of the equipment."
|
|
INDEX { channelIndex }
|
|
::= { channelTable 1 }
|
|
|
|
ChannelEntry ::= SEQUENCE
|
|
{
|
|
channelIndex INTEGER, -- nspiTTPIndex
|
|
channelEncaps ChannelEncaps,
|
|
channelNbVc4 INTEGER,
|
|
channelNbVc3 INTEGER,
|
|
channelNbVc12 INTEGER,
|
|
channelConcat ChannelConcat,
|
|
channelAdminStatus INTEGER,
|
|
channelOperStatus INTEGER,
|
|
channelFirstIndex INTEGER,
|
|
channelDelay INTEGER,
|
|
channelMonitor SagemBoolean,
|
|
channelFailure ChannelFailure,
|
|
channelSeverity Severity,
|
|
channelLoa Severity,
|
|
channelLom Severity,
|
|
channelSqm Severity
|
|
}
|
|
|
|
channelIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular
|
|
SDH Channel.
|
|
The value of index is a constant assigned to an entry at
|
|
equipment design time. It is usualy related to harware."
|
|
::= { channelEntry 1 }
|
|
|
|
channelEncaps OBJECT-TYPE
|
|
SYNTAX ChannelEncaps
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of encapsulation used to map Data stream into Sdh containers"
|
|
::= { channelEntry 2 }
|
|
|
|
channelNbVc4 OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of VC4 into the channel. "
|
|
::= { channelEntry 5 }
|
|
|
|
channelNbVc3 OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of VC3 into the channel. "
|
|
::= { channelEntry 6 }
|
|
|
|
channelNbVc12 OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of VC12 into the channel. "
|
|
::= { channelEntry 7 }
|
|
|
|
channelConcat OBJECT-TYPE
|
|
SYNTAX ChannelConcat
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of Concatenation used within the channel"
|
|
::= { channelEntry 8 }
|
|
|
|
channelAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1), -- ready to pass packets
|
|
down(2),
|
|
testing(3) -- in some test mode
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The desired state of the channel. The
|
|
testing(3) state indicates that no operational
|
|
packets can be passed."
|
|
::= { channelEntry 9 }
|
|
|
|
channelOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1), -- ready to pass packets
|
|
down(2),
|
|
testing(3) -- in some test mode
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current operational state of the channel.
|
|
The testing(3) state indicates that no operational
|
|
packets can be passed."
|
|
::= { channelEntry 10 }
|
|
|
|
channelFirstIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of the first Vc in the Channel when it is configured.
|
|
Otherwise this field is set to 0. "
|
|
::= { channelEntry 11 }
|
|
|
|
channelDelay OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This field give the maximum delay (in millisecondes) for receiving virtual concatenated frames.
|
|
This field is set to 0 when channelConcat is different to virtual(1) "
|
|
::= { channelEntry 12 }
|
|
|
|
channelMonitor OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the value of this field is set to false, the failure detection
|
|
is stopped for this channel."
|
|
::= { channelEntry 13 }
|
|
|
|
channelFailure OBJECT-TYPE
|
|
SYNTAX ChannelFailure
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active failures on channel"
|
|
::= { channelEntry 14 }
|
|
|
|
channelSeverity OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to failure severity for non-sdh physical port."
|
|
::= { channelEntry 15 }
|
|
|
|
channelLoa OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associated with Loss Of Alignment failure
|
|
for channel."
|
|
::= { channelEntry 16 }
|
|
|
|
channelLom OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associated with Loss Of Multiframe failure
|
|
for channel."
|
|
::= { channelEntry 17 }
|
|
|
|
channelSqm OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity associated with Sequence Mismatch failure
|
|
for channel."
|
|
::= { channelEntry 18 }
|
|
-- End of Channel description
|
|
|
|
|
|
|
|
--*******************************************************************
|
|
--* Bandwidth
|
|
--* This part allows to configure the bandwidth allocated to a Data Card
|
|
--* It gives references of VC which are used by channels.
|
|
--*******************************************************************
|
|
|
|
bandwidthNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of bandwidth units which are available in the equipement.
|
|
The number of units depends on their type (Vc4, Vc3, Vc12), on the number
|
|
of Data card and on the bandwidth size which has been configured for this card.
|
|
For a Data card which is mapped on a STM16, there are 16 Vc4 entries (or 3*16 Vc3 entries
|
|
or 63*16 Vc12 entries) in the BandwidthTable. "
|
|
::= { bandwidth 1 }
|
|
|
|
bandwidthTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BandwidthEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of Bandwidth units in equipment. It represent the bandwidth occupation of each non-sdh card"
|
|
::= { bandwidth 2 }
|
|
|
|
bandwidthEntry OBJECT-TYPE
|
|
SYNTAX BandwidthEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular unit part of a non-sdh card bandwidth."
|
|
INDEX { bandwidthIndex }
|
|
::= { bandwidthTable 1 }
|
|
|
|
BandwidthEntry ::= SEQUENCE
|
|
{
|
|
bandwidthIndex INTEGER, -- VC index
|
|
bandwidthBoardIndex INTEGER, -- BoardIndex
|
|
bandwidthSrcType NspiSrcType, -- VC3, VC12 or VC4
|
|
bandwidthSrcPointer INTEGER, -- VC index
|
|
bandwidthSinkType NspiSrcType, -- Channel
|
|
bandwidthSinkPointer INTEGER, -- channelIndex
|
|
bandwidthAdminStatus INTEGER,
|
|
bandwidthOperStatus INTEGER,
|
|
bandwidthPrevIndex INTEGER, -- VC index
|
|
bandwidthNextIndex INTEGER -- VC index
|
|
}
|
|
|
|
bandwidthIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular unit of a non-sdh card bandwidth.
|
|
The value of index is a Vc Index which change when bandwidthSrcType value is modified. "
|
|
::= { bandwidthEntry 1 }
|
|
|
|
bandwidthBoardIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of the Board that supports the bandwidth unit."
|
|
::= { bandwidthEntry 2 }
|
|
|
|
bandwidthSrcType OBJECT-TYPE
|
|
SYNTAX NspiSrcType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Define the decomposition level of the bandwidth."
|
|
::= { bandwidthEntry 3 }
|
|
|
|
bandwidthSrcPointer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"this field is set to bandwidthIndex when the unit is used by a channel and set to 0 otherwise.
|
|
It defines the TTP and CTP index associated to the channel. "
|
|
::= { bandwidthEntry 4 }
|
|
|
|
bandwidthSinkType OBJECT-TYPE
|
|
SYNTAX NspiSrcType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the kind of the sink Pointer. Usually the value is Channel."
|
|
::= { bandwidthEntry 5 }
|
|
|
|
bandwidthSinkPointer OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the object which sends the data flow to this
|
|
function on unsynchronous port interface side.
|
|
This pointer corresponds to an index in the channelTable. "
|
|
::= { bandwidthEntry 6 }
|
|
|
|
bandwidthAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1), -- ready to pass packets
|
|
down(2),
|
|
testing(3) -- in some test mode
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The desired state of the Vc. The
|
|
testing(3) state indicates that no operational
|
|
packets can be passed."
|
|
::= { bandwidthEntry 7 }
|
|
|
|
bandwidthOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1), -- ready to pass packets
|
|
down(2),
|
|
testing(3) -- in some test mode
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current operational state of the Vc.
|
|
The testing(3) state indicates that no operational
|
|
packets can be passed."
|
|
::= { bandwidthEntry 8 }
|
|
|
|
bandwidthPrevIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the previous VC into the channel. This field is set to 0 if the VC is not
|
|
associated to a channel or if it is the first Vc of the channel. "
|
|
::= { bandwidthEntry 9 }
|
|
|
|
bandwidthNextIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to the next VC into the channel. This field is set to 0 if the VC is not
|
|
associated to a channel or if it is the last Vc of the channel. "
|
|
::= { bandwidthEntry 10 }
|
|
|
|
-- End of Bandwidth description
|
|
|
|
END
|
|
|
|
|