mibs/MIBS/siae/SIAE-EQUIP-MIB
2023-12-05 12:25:34 +01:00

594 lines
20 KiB
Plaintext

-- ----------------------------------------------------------------------------
--
-- SIAE MICROELETTRONICA s.p.a.
--
-- Via Michelangelo Buonarroti, 21
-- 20093 - Cologno Monzese
-- Milano
-- ITALY
--
-- ----------------------------------------------------------------------------
-- ----------------------------------------------------------------------------
SIAE-EQUIP-MIB
DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE,
Integer32, IpAddress, TimeTicks
FROM SNMPv2-SMI
DisplayString, AutonomousType
FROM SNMPv2-TC
InterfaceIndex
FROM IF-MIB
siaeMib
FROM SIAE-TREE-MIB
AlarmStatus, AlarmSeverityCode, alarmTrap
FROM SIAE-ALARM-MIB
equipTypeUnknown
FROM SIAE-EQUIPTYPE-MIB;
equipment MODULE-IDENTITY
LAST-UPDATED "201503230000Z"
ORGANIZATION "SIAE MICROELETTRONICA spa"
CONTACT-INFO
"SIAE MICROELETTONICA s.p.a.
Via Michelangelo Buonarroti, 21
20093 - Cologno Monzese
Milano - ITALY
Phone : +39-02-27325-1
E-mail: help@siaemic.com
"
DESCRIPTION
"Common parameters of SIAE equipments.
"
REVISION "201503230000Z"
DESCRIPTION
"Removed alarmTrapNumber from TRAPs and IMPORTS.
"
REVISION "201412030000Z"
DESCRIPTION
"MIB version 01.00.02
Added equipIpEthDefGatewayIfIndex
"
REVISION "201407010000Z"
DESCRIPTION
"MIB version 01.00.01
Added equipIpEthVlanId and equipIpEthDefGateway
"
REVISION "201406230000Z"
DESCRIPTION
"Fixed IMPORTS clause
"
REVISION "201402030000Z"
DESCRIPTION
"Improved description of equipMibVersion
"
REVISION "201304160000Z"
DESCRIPTION
"Initial version 01.00.00
"
::= { siaeMib 1 }
----------------------------------------------------------------------------------
-- SIAE equipment GROUP
----------------------------------------------------------------------------------
--
-- The following listed objects are general object common to all SIAE equipment.
--
----------------------------------------------------------------------------------
------ Beginning --------------------------------------------------------------
equipMibVersion OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Numerical version of this module.
The string version of this MIB have the following format:
XX.YY.ZZ
so, for example, the value 1 should be interpreted as 00.00.01
and the value 10001 should be interpreted as 01.00.01."
DEFVAL {1}
::= {equipment 1}
equipCurrentTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Seconds since 1/1/1970."
::= {equipment 2}
equipUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time since the system was last re-initialized (in seconds
since 1/1/1970)."
::= {equipment 3}
equipType OBJECT-TYPE
SYNTAX AutonomousType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of SIAE MICROELETTRONICA's equipment"
DEFVAL { equipTypeUnknown }
::= {equipment 4}
-- OBJECT-IDENTIFIER {equipment 5} is used in sm_equiptype.mib
equipIpEthOsiAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ip address of the equipment on Ethernet-OSI interface."
::= {equipment 6}
equipGosipAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"GOSIP address of the equipment."
::= {equipment 7}
equipIpEthOsiNetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The subnet Mask associated with the IP address of OSI ethernet interface.
The value of the Mask is an IP address with all the network bits set to 1
and all the hosts bits set to 0."
::= {equipment 8}
equipL1L2IsIsRouting OBJECT-TYPE
SYNTAX INTEGER {
l1 (1),
l2 (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It defines the IS-IS routing type: L1 within the same area, L2 among
different areas."
DEFVAL {l1}
::= {equipment 9}
equipStationID OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ASCII string assigned by the operator to identify the specific equipment."
::= {equipment 10}
equipLOMConfigEnable OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/disables the capabilityto connect a LOM in Configuration Mode."
::= {equipment 11}
equipLOMConnected OBJECT-TYPE
SYNTAX INTEGER {
cleared (1),
connectionAsMonitor (2),
connectionAsConfig (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal when the LOM is connected to the NE and if the connection
is for monitor or configuration."
::= {equipment 12}
equipLOMConnectedTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
trapDisable (1),
trapEnable (2),
trapEnableWithAck (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/disables the trap generation on EquipLOMConnected status change event."
DEFVAL {trapEnable}
::= {equipment 13}
equipConfigChange OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set by the NE when the equipment configuration is changed by the local
or Remote LOM.
The octet string is a bit stream of flags; a set bit is a change on a
specific item. We had:
Byte 0.7: change in configuration for equipment group
Byte 0.6: change in configuration for userInput group
Byte 0.5: change in configuration for userOutput group
Byte 0.4: change in configuration for alarmLog group
......
Byte 3.7: change in a severity for equipment group
Byte 3.6: change in a severity for userInput group
Byte 3.5: change in a severity for userOutput group
Byte 3.4: change in a severity for alarmLog group
CEM can reset the change condition writing one to desired bit flag
......"
::= {equipment 14}
equipConfigChangeTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
trapDisable (1),
trapEnable (2),
trapEnableWithACK (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/disables the trap generation on EquipConfigChange status
change event."
DEFVAL {trapEnable}
::= {equipment 15}
equipRequest OBJECT-TYPE
SYNTAX INTEGER {
notActive (0), -- no write-only in v2
restart (1),
applyIfChange (2),
revertIfChange (3),
configClearAndRestart (4),
routeTableClear (5),
uploadBaseBand (6),
offLineRouteRetrieve (7),
offLineRouteSave (8),
hotApplyIfChange (11),
ipStackConfigure (20),
osiStackConfigure (21),
atuTableReset (50),
siaeReservedReq1 (100),
siaeReservedReq26 (125),
siaeReservedReq27 (126),
switchFactoryDefault (127)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Force Equipment Controller restart or change in interface properties."
::= {equipment 16}
equipIpEthAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ip address of the equipment on Ethernet interface."
::= {equipment 17}
equipIpEthNetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The subnet Mask associated with the IP address of ethernet interface.
The value of the Mask is an IP address with all the network bits set to 1
and all the hosts bits set to 0."
::= {equipment 18}
equipOsiamParameter OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..41))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It defines the set-up parameter for OSI stack."
::= {equipment 19}
equipIpSnmpAgentAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ip address used by SNMP Agent for mark generated TRAP."
::= {equipment 20}
equipOperationInProgress OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A value different from 0 means operation in progress."
DEFVAL {0}
::= {equipment 21}
equipManagerWakeUpAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This alarm switches on when periodic connection wake-up trap starts.
The trap related to this alarm is also sent periodically only to the
manager specified by the leaf equipManagerWakeUpIpAddr when
equipManagerWakeUpAlarmSeverityCode differs from disable."
::= {equipment 22}
equipManagerWakeUpAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the severity associated to the equipManagerWakeUpAlarm
and enables/disables the trap generation on status change event."
DEFVAL {disable}
::= {equipment 23}
equipManagerWakeUpTimeout OBJECT-TYPE
SYNTAX INTEGER (0..1440)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the time (in minutes) after which the periodic
connection wake-up trap is stopped.
The maximium value is equivalent to 24 hours.
When the timeout elapses the equipManagerWakeUpAlarmSeverityCode
is set to disable.
A zero means no timeout."
DEFVAL {60}
::= {equipment 24}
equipManagerWakeUpIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ip Address of manager wich to send a periodic connection wake-up trap.
The periodic trap is sent only if the equipManagerWakeUpAlarmSeverityCode
differs from disable.
If Ip Address equals 0 no trap will be sent."
DEFVAL {'00'H}
::= {equipment 25}
equipManagerWakeUpGosipAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Gosip Address of manager wich to send a periodic connection wake-up trap."
::= {equipment 26}
equipManagerWakeUpTrapVersion OBJECT-TYPE
SYNTAX INTEGER {
trapV1 (1),
trapV2 (2),
trapV3 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap version supported by Manager to wake-up."
DEFVAL {trapV1}
::= {equipment 27}
equipManager1IpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"First IP address of a SNMP Manager always logged to this equipment.
The address 0.0.0.0 mean that manager is not present."
::= {equipment 28}
equipManager2IpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Second IP address of a SNMP Manager always logged to this equipment.
The address 0.0.0.0 mean that manager is not present."
::= {equipment 29}
equipManager1TrapVersion OBJECT-TYPE
SYNTAX INTEGER {
trapV1 (1),
trapV2 (2),
trapV3 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap version supported by Manager 1 (related to equipManager1IpAddr)."
DEFVAL {trapV1}
::= {equipment 30}
equipManager2TrapVersion OBJECT-TYPE
SYNTAX INTEGER {
trapV1 (1),
trapV2 (2),
trapV3 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trap version supported by Manager 2 (related to equipManager2IpAddr)."
DEFVAL {trapV1}
::= {equipment 31}
equipDailyPmTimeZone OBJECT-TYPE
SYNTAX INTEGER (-12..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reference GMT Time Zone to close the daily P.M. records."
DEFVAL {0}
::= {equipment 32}
equipOperationMngtControl OBJECT-TYPE
SYNTAX INTEGER {
notActive (0), -- no write-only in v2
startOperation (1),
confirmOperation (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"startOperation means the apply of the 'management parameters
set' on the E6165 switch.
confirmOperation means the backup of the 'management
parameters set'."
DEFVAL {0}
::= {equipment 33}
equipOperationMngtInProgress OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A value different from 0 means Mngt operation in progress."
::= {equipment 34}
equipLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ASCII string assigned by the operator to identify the location of
specific equipment."
::= {equipment 35}
equipLongitude OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Geographic coordinate that specifies the east-west position of
the equipment.
In order to calculate the latitude in degrees the formula to be
applied is
Longitude = equipLongitude*180/2^31
This object is used with equipLatitude to locate the equipment
on a map.
"
::= {equipment 36}
equipLatitude OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Geographic coordinate that specifies the north-south position of
the equipment.
In order to calculate the latitude in degrees the formula to be
applied is
Latitude = equipLatitude*180/2^31
This object is used with equipLongitude to locate the equipment
on a map.
"
::= {equipment 37}
equipIpEthVlanId OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ethernet vlan id on top of which management is built"
DEFVAL { 1 }
::= { equipment 38 }
equipIpEthDefGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ip address of the default gateway on Ethernet interface."
::= {equipment 39}
equipIpEthDefGatewayIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex(1..999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Ip address of the default gateway on Ethernet interface."
::= {equipment 40}
-----------------------
--
-- The equipment Group generates the following TRAPs:
--
-----------------------
equipLOMConnectedMonitor NOTIFICATION-TYPE
OBJECTS {equipIpSnmpAgentAddress, equipLOMConnected}
STATUS current
DESCRIPTION
"This event is generated by ALFOHD-NE when equipLOMConnected is set to Monitor mode.
The data passed with the event are:
1) equipIpSnmpAgentAddress
2) equipLOMConnected"
::= {alarmTrap 109}
equipLOMConnectedConfig NOTIFICATION-TYPE
OBJECTS {equipIpSnmpAgentAddress, equipLOMConnected}
STATUS current
DESCRIPTION
"This event is generated by ALFOHD-NE when equipLOMConnected is set to Configuration mode.
The data passed with the event are:
1) equipIpSnmpAgentAddress
2) equipLOMConnected"
::= {alarmTrap 110}
equipLOMDisconnected NOTIFICATION-TYPE
OBJECTS {equipIpSnmpAgentAddress, equipLOMConnected}
STATUS current
DESCRIPTION
"This event is generated by ALFOHD-NE when LOMConnected is cleared.
The data passed with the event are:
1) equipIpSnmpAgentAddress
2) equipLOMConnected"
::= {alarmTrap 111}
equipConfigChangeStatus NOTIFICATION-TYPE
OBJECTS {equipIpSnmpAgentAddress, equipConfigChange}
STATUS current
DESCRIPTION
"This event is generated by ALFOHD-NE when equipConfigChange is changed.
The data passed with the event are:
1) equipIpSnmpAgentAddress
2) equipConfigChange"
::= {alarmTrap 114}
equipManagerWakeUpNotify NOTIFICATION-TYPE
OBJECTS {equipIpSnmpAgentAddress, equipStationID, equipLocation, equipIpSnmpAgentAddress, equipGosipAddress,
equipManagerWakeUpIpAddr, equipManagerWakeUpAlarm}
STATUS current
DESCRIPTION
" This trap is sent periodically only to the manager specified by
the leaf equipManagerWakeUpIpAddr when equipManagerWakeUpAlarmSeverityCode
differs from disable.
The data passed with the event are:
1) equipIpSnmpAgentAddress
2) equipStationID
3) equipLocation
4) equipIpSnmpAgentAddress
5) equipGosipAddress
6) equipManagerWakeUpIpAddr
7) equipManagerWakeUpAlarm"
::= {alarmTrap 123}
------ End group -----------------------------------------------------------------
END