2054 lines
78 KiB
Plaintext
2054 lines
78 KiB
Plaintext
-- ----------------------------------------------------------------------------
|
|
--
|
|
-- SIAE MICROELETTRONICA s.p.a.
|
|
--
|
|
-- Via Michelangelo Buonarroti, 21
|
|
-- 20093 - Cologno Monzese
|
|
-- Milano
|
|
-- ITALY
|
|
--
|
|
-- ----------------------------------------------------------------------------
|
|
-- ----------------------------------------------------------------------------
|
|
|
|
SIAE-PTP-MIB
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
DisplayString, RowStatus, TruthValue, TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
InterfaceIndex
|
|
FROM IF-MIB
|
|
siaeMib
|
|
FROM SIAE-TREE-MIB
|
|
AlarmStatus, AlarmSeverityCode
|
|
FROM SIAE-ALARM-MIB;
|
|
|
|
ptp MODULE-IDENTITY
|
|
LAST-UPDATED "201605050000Z"
|
|
ORGANIZATION "SIAE MICROELETTRONICA spa"
|
|
CONTACT-INFO
|
|
"SIAE MICROELETTONICA s.p.a.
|
|
Via Michelangelo Buonarroti, 21
|
|
20093 - Cologno Monzese
|
|
Milano - ITALY
|
|
Phone : +39-02-27325-1
|
|
E-mail: help@siaemic.com
|
|
"
|
|
DESCRIPTION
|
|
"SIAE's Precision Time Protocol MIB.
|
|
For details see:
|
|
[1] IEEE Std 1588(TM)-2008, Standard for a Precision Clock
|
|
Synchronization Protocol for Networked Measurement and
|
|
Control Systems, 2008.
|
|
[2] Recommendation ITU-T G.8275.1/Y1369.1, Precision time protocol
|
|
telecom profile for phase/time synchronization with full timing
|
|
support from the network, draft 4 Apr 2014 . "
|
|
::= { siaeMib 100 }
|
|
|
|
--
|
|
-- Textual Conventions for PTP
|
|
--
|
|
|
|
ClockDomainType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Domain is identified by an integer, the domainNumber, in
|
|
the range of 0 to 255. An integer value that is used to assign
|
|
each PTP device to a particular domain. The following values
|
|
define the valid domains. [1] Section 7.1 Domains Table 2
|
|
|
|
Value definition.
|
|
--------- -------------------
|
|
0 Default domain
|
|
1 Alternate domain 1
|
|
2 Alternate domain 2
|
|
3 Alternate domain 3
|
|
4 - 23 User-defined domains
|
|
24 - 43 Telecom Profile domains
|
|
44 - 127 User-defined domains
|
|
128 - 255 Reserved"
|
|
|
|
REFERENCE "Section 7.1 Domains and Table 2 of [1]"
|
|
SYNTAX Unsigned32 (24..43)
|
|
|
|
ClockProfileType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock Profile used. A profile is the set of allowed Precision
|
|
Time Protocol (PTP) features applicable to a device."
|
|
|
|
REFERENCE "Section 3.1.30 and 19.3 PTP profiles of
|
|
[IEEE 1588-2008]"
|
|
SYNTAX INTEGER {
|
|
default(1),
|
|
telecom(2),
|
|
vendorspecific(3)
|
|
}
|
|
|
|
ClockQualityAccuracyType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ClockQuality as specified in section 5.3.7, 7.6.2.5 and
|
|
Table 6 of [1].
|
|
|
|
The following values are not represented in the enumerated
|
|
values.
|
|
|
|
0x01-0x1F Reserved
|
|
0x32-0x7F Reserved
|
|
|
|
It is important to note that section 7.1.1 RFC2578 allows for
|
|
gaps and enumerate values to start with zero when indicated by
|
|
the protocol."
|
|
|
|
REFERENCE "Section 5.3.7, 7.6.2.5 and Table 6 of [1]"
|
|
SYNTAX INTEGER {
|
|
reserved00(1), -- 0
|
|
nanoSecond25(32), -- 0x20
|
|
nanoSecond100(33), -- 0x21
|
|
nanoSecond250(34), -- 0x22
|
|
microSec1(35), -- 0x23
|
|
microSec2dot5(36), -- 0x24
|
|
microSec10(37), -- 0x25
|
|
microSec25(38), -- 0x26
|
|
microSec100(39), -- 0x27
|
|
microSec250(40), -- 0x28
|
|
milliSec1(41), -- 0x29
|
|
milliSec2dot5(42), -- 0x2A
|
|
milliSec10(43), -- 0x2B
|
|
milliSec25(44), -- 0x2C
|
|
milliSec100(45), -- 0x2D
|
|
milliSec250(46), -- 0x2E
|
|
second1(47), -- 0x2F
|
|
second10(48), -- 0x30
|
|
secondGreater10(49), -- 0x31
|
|
unknown(254), -- 0xFE
|
|
reserved255(255) -- 0xFF
|
|
}
|
|
|
|
ClockQualityClassType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ClockQuality as specified in section 5.3.7, 7.6.2.4 and
|
|
Table 5 of [1].
|
|
|
|
Value Description
|
|
------
|
|
----------------------------------------------------------
|
|
0 Reserved to enable compatibility with future
|
|
versions.
|
|
1-5 Reserved
|
|
6 Shall designate a clock that is synchronized
|
|
to a primary reference time source. The
|
|
timescale distributed shall be PTP. A
|
|
clockClass 6 clock shall not be a slave to
|
|
another clock in the domain.
|
|
7 Shall designate a clock that has previously
|
|
been designated as clockClass 6 but that has
|
|
lost the ability to synchronize to a primary
|
|
reference time source and is in holdover mode
|
|
and within holdover specifications. The
|
|
timescale distributed shall be PTP. A
|
|
clockClass 7 clock shall not be a slave to
|
|
another clock in the domain.
|
|
8 Reserved.
|
|
9-10 Reserved to enable compatibility with future
|
|
versions.
|
|
11-12 Reserved.
|
|
13 Shall designate a clock that is synchronized
|
|
to an application-specific source of time.
|
|
The timescale distributed shall be ARB. A
|
|
clockClass 13 clock shall not be a slave to
|
|
another clock in the domain.
|
|
14 Shall designate a clock that has previously
|
|
been designated as clockClass 13 but that
|
|
has lost the ability to synchronize to an
|
|
application-specific source of time and is
|
|
in holdover mode and within holdover
|
|
specifications. The timescale distributed
|
|
shall be ARB. A clockClass 14 clock shall
|
|
not be a slave to another clock in the domain.
|
|
15-51 Reserved.
|
|
52 Degradation alternative A for a clock of
|
|
clockClass 7 that is not within holdover
|
|
specification. A clock of clockClass 52
|
|
shall not be a slave to another clock in
|
|
the domain.
|
|
53-57 Reserved.
|
|
58 Degradation alternative A for a clock of
|
|
clockClass 14 that is not within holdover
|
|
specification. A clock of clockClass 58 shall
|
|
not be a slave to another clock in the domain.
|
|
59-67 Reserved.
|
|
68-122 For use by alternate PTP profiles.
|
|
123-127 Reserved.
|
|
128-132 Reserved.
|
|
133-170 For use by alternate PTP profiles.
|
|
171-186 Reserved.
|
|
|
|
187 Degradation alternative B for a clock of
|
|
clockClass 7 that is not within holdover
|
|
specification. A clock of clockClass 187 may
|
|
be a slave to another clock in the domain.
|
|
188-192 Reserved.
|
|
193 Degradation alternative B for a clock of
|
|
clockClass 14 that is not within holdover
|
|
specification. A clock of clockClass 193 may
|
|
be a slave to another clock in the domain.
|
|
194-215 Reserved.
|
|
216-232 For use by alternate PTP profiles.
|
|
233-247 Reserved.
|
|
248 Default. This clockClass shall be used if
|
|
none of the other clockClass definitions apply.
|
|
249-250 Reserved.
|
|
251 Reserved for version 1 compatibility; see Clause 18.
|
|
252-254 Reserved.
|
|
255 Shall be the clockClass of a slave-only clock; see
|
|
9.2.2.
|
|
|
|
The ClockQuality as specified in section 6.4 and
|
|
Table 2 of [2].
|
|
|
|
Value Description
|
|
------
|
|
----------------------------------------------------------
|
|
6 T-GM connected to a PRTC in locked mode
|
|
(e.g. PRTC traceable to GNSS)
|
|
140 T-GM in holdover, out of holdover specification,
|
|
traceable to Category 1 frequency source
|
|
150 T-GM in holdover, out of holdover specification,
|
|
traceable to Category 2 frequency source
|
|
160 T-GM in holdover, out of holdover specification,
|
|
traceable to Category 3 frequency source
|
|
165 T-BC in holdover, out of holdover specification,
|
|
using unspecified frequency source
|
|
255 Slave only OC (does not send Announce messages)
|
|
|
|
"
|
|
|
|
REFERENCE "section 5.3.7, 7.6.2.4 and Table 5 of [1].
|
|
section 6.4 and Table 2 of [2]"
|
|
SYNTAX INTEGER (0..255)
|
|
|
|
ClockStateType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clock state returned by PTP engine.
|
|
|
|
Clock State Value Description
|
|
--------------------------------------------------------------
|
|
Freerun state 1 The PTP clock has never been synchronized
|
|
to a time source and is not in the process
|
|
of synchronizing to a time source.
|
|
As it relates to the PTP port state defined
|
|
in [IEEE 1588], a clock is in Free-Run state
|
|
if there are no PTP ports in: MASTER,
|
|
PRE-MASTER, PASSIVE, UNCALIBRATED,
|
|
or SLAVE states.
|
|
|
|
Acquiring state 2 The PTP clock is in process of synchronizing
|
|
to a time source. The duration and functionality
|
|
of this state is implementation specific. This
|
|
state is not required in an implementation.
|
|
As it relates to the PTP port state defined in
|
|
[IEEE 1588], a clock is in Acquiring state if
|
|
there is a PTP port in UNCALIBRATED state.
|
|
|
|
Locked state 3 The PTP clock is synchronized to a time source
|
|
and is within some internal acceptable accuracy.
|
|
As it relates to the PTP port state defined in
|
|
[IEEE 1588], a clock is in Locked state if there
|
|
is a PTP port in SLAVE state.
|
|
|
|
HoldoverInSpec state 4 The PTP clock is no longer synchronized to a
|
|
time source and is using information obtained
|
|
while it was previously synchronized or other
|
|
information sources were still available, to
|
|
maintain performance within desired specification.
|
|
The node may be relying solely on its own
|
|
facilities for holdover or may use something
|
|
like a frequency input from the network to
|
|
achieve a holdover of time and/or phase.
|
|
As it relates to the PTP port state defined in
|
|
[IEEE 1588], a clock is in HoldoverInSpec
|
|
state if there are no PTP ports in: INITIALIZING,
|
|
LISTENING, UNCALIBRATED or SLAVE states, and
|
|
performance is within desired specification.
|
|
|
|
HoldoverOutOfSpec state 5 The PTP clock is no longer synchronized to a time
|
|
source and, while it may be using information
|
|
obtained while it was previously synchronized or
|
|
other information sources were still available,
|
|
it is unable to maintain performance within
|
|
desired specification.
|
|
As it relates to the PTP port state defined in
|
|
[IEEE 1588], a clock is in HoldoverOutOfSpec
|
|
state if there are no PTP ports in: INITIALIZING,
|
|
LISTENING, UNCALIBRATED or SLAVE states, and
|
|
performance is not within desired specification."
|
|
SYNTAX INTEGER {
|
|
freerun(1),
|
|
acquiring(2),
|
|
locked(3),
|
|
holdoverInSpec(4),
|
|
holdoverOutOfSpec(5)
|
|
}
|
|
|
|
ClockTimeSourceType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ClockQuality as specified in section 5.3.7, 7.6.2.6 and
|
|
Table 7 of [1].
|
|
|
|
The following values are not represented in the enumerated
|
|
values.
|
|
|
|
0xF0-0xFE For use by alternate PTP profiles
|
|
0xFF Reserved
|
|
|
|
It is important to note that section 7.1.1 RFC2578 allows for
|
|
gaps and enumerate values to start with zero when indicated by
|
|
the protocol."
|
|
|
|
REFERENCE "section 5.3.7, 7.6.2.6 and Table 7 of [1]."
|
|
SYNTAX INTEGER {
|
|
atomicClock(16), -- 0x10
|
|
gps(32), -- 0x20
|
|
terrestrialRadio(48), -- 0x22
|
|
ptp(64), -- 0x40
|
|
ntp(80), -- 0x50
|
|
handSet(96), -- 0x60
|
|
other(144), -- 0x90
|
|
internalOscillator(160), -- 0xA0
|
|
reserved(255) --0xFF
|
|
}
|
|
|
|
ClockInstanceType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance of the Clock of a given clock type in a given
|
|
domain."
|
|
SYNTAX Unsigned32 (0..255)
|
|
|
|
|
|
ClockPPSInstanceType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The instance of the PPS (and ToD) socket."
|
|
SYNTAX Unsigned32 (0..255)
|
|
|
|
|
|
ClockPortNumber ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index identifying a specific Precision Time Protocol (PTP)
|
|
port on a PTP node."
|
|
REFERENCE "Section 7.5.2.3 Port Number and 5.3.5 of [1]"
|
|
SYNTAX Unsigned32 (0..65535)
|
|
|
|
|
|
ClockPortState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the value of the current state of the protocol engine
|
|
associated with this port.
|
|
Port state Value Description
|
|
-----------------------------------------------------------
|
|
initializing 1 In this state a port initializes
|
|
its data sets, hardware, and
|
|
communication facilities.
|
|
faulty 2 The fault state of the protocol.
|
|
disabled 3 The port shall not place any
|
|
messages on its communication path.
|
|
listening 4 The port is waiting for the
|
|
announceReceiptTimeout to expire or
|
|
to receive an Announce message from
|
|
a master.
|
|
preMaster 5 The port shall behave in all respects
|
|
as though it were in the MASTER state
|
|
except that it shall not place any
|
|
messages on its communication path
|
|
except for Pdelay_Req, Pdelay_Resp,
|
|
Pdelay_Resp_Follow_Up, signaling, or
|
|
management messages.
|
|
master 6 The port is behaving as a master
|
|
port.
|
|
passive 7 The port shall not place any
|
|
messages on its communication path
|
|
except for Pdelay_Req, Pdelay_Resp,
|
|
Pdelay_Resp_Follow_Up, or signaling
|
|
messages, or management messages
|
|
that are a required response to
|
|
another management message
|
|
uncalibrated 8 The local port is preparing to
|
|
synchronize to the master port.
|
|
slave 9 The port is synchronizing to the
|
|
selected master port."
|
|
|
|
REFERENCE "Section 8.2.5.3.1 portState and 9.2.5 of [1]"
|
|
SYNTAX INTEGER {
|
|
initializing(1),
|
|
faulty(2),
|
|
disabled(3),
|
|
listening(4),
|
|
preMaster(5),
|
|
master(6),
|
|
passive(7),
|
|
uncalibrated(8),
|
|
slave(9)
|
|
}
|
|
|
|
ClockMechanismType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clock type based on whether End to End or peer to peer
|
|
mechanisms are used. The mechanism used to calculate the Mean
|
|
Path Delay as indicated in Table 9 of IEEE 1588-2008.
|
|
|
|
Delay mechanism Value(hex) Specification
|
|
E2E 01 The port is configured to use
|
|
the delay request-response
|
|
mechanism.
|
|
|
|
P2P 02 The port is configured to use
|
|
the peer delay mechanism.
|
|
|
|
DISABLED FE The port does not implement
|
|
the delay mechanism."
|
|
|
|
REFERENCE "Sections 8.2.5.4.4, 6.6.4 and 7.4.2 of [1]."
|
|
SYNTAX INTEGER {
|
|
e2e(1)
|
|
-- p2p(2),
|
|
-- disabled(254)
|
|
}
|
|
|
|
ClockTimeInterval ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This textual convention corresponds to the TimeInterval
|
|
structure indicated in section 5.3.2 of [1]. It will be
|
|
presented in the form of a character array.
|
|
|
|
The TimeInterval type represents time intervals.
|
|
|
|
struct TimeInterval
|
|
{
|
|
Integer64 scaledNanoseconds;
|
|
};
|
|
|
|
The scaledNanoseconds member is the time interval expressed in
|
|
units of nanoseconds and multiplied by 2**16.
|
|
|
|
Positive or negative time intervals outside the maximum range
|
|
of this data type shall be encoded as the largest positive and
|
|
negative values of the data type, respectively.
|
|
|
|
For example, 2.5 ns is expressed as 0000 0000 0002 8000 in
|
|
Base16."
|
|
|
|
REFERENCE
|
|
"Section 5.3.2 and setion 7.7.2.1 Timer interval
|
|
specification of [1]"
|
|
SYNTAX OCTET STRING (SIZE (1..255))
|
|
|
|
ClockType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clock types as defined in the MIB module description."
|
|
|
|
REFERENCE "section 6.5.1 of [1]."
|
|
SYNTAX INTEGER {
|
|
--ordinaryClock(1),
|
|
boundaryClock(2)
|
|
--transparentClock(3),
|
|
--boundaryNode(4)
|
|
}
|
|
|
|
PtpClockToDFormatType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the format used for ToD signal in input or in output direcdtion.
|
|
|
|
-----------------------------------------------------------
|
|
Format Value Description
|
|
-----------------------------------------------------------
|
|
telecomTimeEvent 1
|
|
telecomTimeAnnounce 2
|
|
telecomGNSSstatus 3
|
|
NMEAzda 4 ASCII format (eg: $GPZDA,003157.00,01,01,1970,00,00*69)
|
|
ISO8601 5 ASCII format (eg: 1970-01-01T00:32:47Z)
|
|
NTP 6 ASCII format (eg: 70 001 00:30:51.000 S)
|
|
Ublox 7 Not ASCII
|
|
ChinaMobile 8 Not ASCII
|
|
ChinaTelecom 9 Not ASCII (standard ITU G.8271 is derived from this)
|
|
BCM 10 Not ASCII
|
|
BCMTS 11 Not ASCII
|
|
-----------------------------------------------------------"
|
|
SYNTAX INTEGER {
|
|
telecomTimeEvent(1),
|
|
telecomTimeAnnounce(2),
|
|
telecomGNSSstatus(3),
|
|
nmeazda(4),
|
|
iso8601(5),
|
|
ntp(6),
|
|
ublox(7),
|
|
chinaMobile(8),
|
|
chinaTelecom(9),
|
|
bcm(10),
|
|
bcmts(11)
|
|
}
|
|
|
|
--------------------------------------------------------------------------------
|
|
-- PTP GROUP
|
|
--------------------------------------------------------------------------------
|
|
--
|
|
-- This group is used for Precision Time Protocol version 2 configuration and alarm reporting
|
|
--
|
|
-- For details see:
|
|
-- [1] IEEE Std 1588(TM)-2008, Standard for a Precision Clock
|
|
-- Synchronization Protocol for Networked Measurement and
|
|
-- Control Systems, 2008.
|
|
-- [2] Recommendation ITU-T G.8275.1/Y1369.1, Precision time protocol
|
|
-- telecom profile for phase/time synchronization with full timing
|
|
-- support from the network, draft 4 Apr 2014 .
|
|
--
|
|
--------------------------------------------------------------------------------
|
|
|
|
------ Beginning --------------------------------------------------------------
|
|
|
|
ptpMibVersion OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Numerical version of this module.
|
|
The string version of this MIB have the following format:
|
|
XX.YY.ZZ
|
|
so, for example, the value 1 should be interpreted as 00.00.01
|
|
and the value 10001 should be interpreted as 01.00.01."
|
|
DEFVAL {1}
|
|
::= { ptp 1 }
|
|
|
|
|
|
ptpProfileDataSet OBJECT IDENTIFIER ::= { ptp 2 }
|
|
ptpSpecificDataSet OBJECT IDENTIFIER ::= { ptp 3 }
|
|
ptpDefaultDataSet OBJECT IDENTIFIER ::= { ptp 4 }
|
|
ptpCurrentDataSet OBJECT IDENTIFIER ::= { ptp 5 }
|
|
ptpParentDataSet OBJECT IDENTIFIER ::= { ptp 6 }
|
|
ptpTimePropertiesDataSet OBJECT IDENTIFIER ::= { ptp 7 }
|
|
ptpPortDataSet OBJECT IDENTIFIER ::= { ptp 8 }
|
|
ptpClockPPSDataSet OBJECT IDENTIFIER ::= { ptp 9 }
|
|
ptpRadioAsymmetryDataSet OBJECT IDENTIFIER ::= { ptp 10 }
|
|
|
|
------- Begin of Ptp Profile data set.
|
|
--
|
|
|
|
ptpSystemProfile OBJECT-TYPE
|
|
SYNTAX ClockProfileType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the PTP Profile implemented on the
|
|
system."
|
|
REFERENCE "Section 19.3 PTP profiles of [1]"
|
|
::= { ptpProfileDataSet 1 }
|
|
|
|
ptpProfileName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..128))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object describes the PTP Profile implemented on the system."
|
|
REFERENCE "Section 19.3 PTP profiles of [1]"
|
|
-- DEFVAL { "ITU-T PTP profile for phase/time distribution with full timing support from the network" }
|
|
::= { ptpProfileDataSet 2 }
|
|
|
|
ptpProfilePrimaryVersion OBJECT-TYPE
|
|
SYNTAX Integer32(0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version of the profile consist of two fields: a primaryVersion
|
|
and a revisionNumber. The profileVersion shall be printed as
|
|
primaryVersion.revisionNumber
|
|
"
|
|
REFERENCE "Section 19.3 PTP profiles of [1]"
|
|
DEFVAL { 1 }
|
|
::= { ptpProfileDataSet 3 }
|
|
|
|
ptpProfileRevisionNumber OBJECT-TYPE
|
|
SYNTAX Integer32(0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version of the profile consist of two fields: a primaryVersion
|
|
and a revisionNumber. The profileVersion shall be printed as
|
|
primaryVersion.revisionNumber
|
|
"
|
|
REFERENCE "Section 19.3 PTP profiles of [1]"
|
|
DEFVAL { 0 }
|
|
::= { ptpProfileDataSet 4 }
|
|
|
|
ptpProfileIdentifier OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(6))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object show the PTP Profile version on the system."
|
|
REFERENCE "Section 19.3 PTP profiles of [1]"
|
|
DEFVAL {'0019A7010100'h}
|
|
::= { ptpProfileDataSet 5 }
|
|
|
|
--
|
|
------- End of Ptp Profile data set.
|
|
|
|
|
|
|
|
|
|
------- Begin of Ptp Default data set.
|
|
-- Characterizes the PTP clock of the system.
|
|
--
|
|
|
|
ptpClockDataSetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PtpClockDataSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the PTP clock Default Datasets for
|
|
all domains."
|
|
::= { ptpDefaultDataSet 1 }
|
|
|
|
ptpClockDataSetEntry OBJECT-TYPE
|
|
SYNTAX PtpClockDataSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the information of the clock on a particular doamin. This
|
|
table will be initialised with default values if the clock is
|
|
operating as a boundary or ordinary clock in the domain."
|
|
INDEX { ptpClockDomainIndex,
|
|
ptpClockTypeIndex,
|
|
ptpClockInstanceIndex }
|
|
::= { ptpClockDataSetTable 1 }
|
|
|
|
PtpClockDataSetEntry ::= SEQUENCE {
|
|
ptpClockDomainIndex ClockDomainType,
|
|
ptpClockTypeIndex ClockType,
|
|
ptpClockInstanceIndex ClockInstanceType,
|
|
ptpClockIdentity OCTET STRING,
|
|
ptpClockTwoStepFlag TruthValue,
|
|
ptpClockNumberPorts Integer32,
|
|
ptpClockClass ClockQualityClassType,
|
|
ptpClockAccuracy ClockQualityAccuracyType,
|
|
ptpClockOffsetScaledLogVariance Integer32,
|
|
ptpClockPriority1 Integer32,
|
|
ptpClockPriority2 Integer32,
|
|
ptpClockSlaveOnly TruthValue,
|
|
ptpClockLocalPriority INTEGER,
|
|
ptpClockRowStatus RowStatus
|
|
}
|
|
|
|
ptpClockDomainIndex OBJECT-TYPE
|
|
SYNTAX ClockDomainType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the domain number used to create logical
|
|
group of PTP devices. The Clock Domain is a logical group of
|
|
clocks and devices that synchronize with each other using the
|
|
PTP protocol."
|
|
::= { ptpClockDataSetEntry 1 }
|
|
|
|
ptpClockTypeIndex OBJECT-TYPE
|
|
SYNTAX ClockType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the clock type as defined in the
|
|
Textual convention description."
|
|
::= { ptpClockDataSetEntry 2 }
|
|
|
|
ptpClockInstanceIndex OBJECT-TYPE
|
|
SYNTAX ClockInstanceType (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the instance of the Clock for this clock
|
|
type for the given domain."
|
|
::= { ptpClockDataSetEntry 3 }
|
|
|
|
ptpClockIdentity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the unique identity of the local clock or management node.
|
|
This should be the smptpDomainClockIdentity of the domain indicated
|
|
by the ptpDomainNumber. Configuration of this value will take effect
|
|
only when the PTP module is enabled."
|
|
::= {ptpClockDataSetEntry 4 }
|
|
|
|
ptpClockTwoStepFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is TRUE if the clock is two step clock, otherwise it is
|
|
FALSE. If this value is configured as TRUE, then PTP will transmit the
|
|
originTimeStamp only through follow-up messages."
|
|
DEFVAL { false }
|
|
::= { ptpClockDataSetEntry 5 }
|
|
|
|
ptpClockNumberPorts OBJECT-TYPE
|
|
SYNTAX Integer32 (1..128)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This indicates the number of PTP ports on the device. For an ordinary
|
|
clock this value should be 1."
|
|
DEFVAL { 6 }
|
|
::= { ptpClockDataSetEntry 6 }
|
|
|
|
ptpClockClass OBJECT-TYPE
|
|
SYNTAX ClockQualityClassType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the default dataset Quality Class."
|
|
DEFVAL { 248 }
|
|
::= { ptpClockDataSetEntry 7 }
|
|
|
|
ptpClockAccuracy OBJECT-TYPE
|
|
SYNTAX ClockQualityAccuracyType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the default dataset Quality Accurarcy."
|
|
DEFVAL { unknown }
|
|
::= { ptpClockDataSetEntry 8 }
|
|
|
|
ptpClockOffsetScaledLogVariance OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is an estimate of the variations of the local clock
|
|
from a linear timescale when it is not synchronized to another
|
|
clock using the protocol. The initialization value depends on the
|
|
inherent characteristics of the clock during initialization. This
|
|
value is used by the BMC algorithm to select the best master clock"
|
|
DEFVAL { 0 }
|
|
::= { ptpClockDataSetEntry 9 }
|
|
|
|
ptpClockPriority1 OBJECT-TYPE
|
|
SYNTAX Integer32 (128)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is used by BMC algorithm to select the best master
|
|
clock. Lower values take precedence."
|
|
DEFVAL { 128 }
|
|
::= { ptpClockDataSetEntry 10 }
|
|
|
|
ptpClockPriority2 OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is used by BMC algorithm to select the best master clock.
|
|
This is used as a tiebreaker when the BMC failes to order the clock
|
|
using ptpClockPriority1, ptpClockClass, ptpClockAccuracy and
|
|
ptpClockOffsetScaledLogVariance.
|
|
Lower values take precedence"
|
|
DEFVAL { 128 }
|
|
::= { ptpClockDataSetEntry 11 }
|
|
|
|
ptpClockSlaveOnly OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuring this value as true will make the clock to behave as slave
|
|
clock.
|
|
A boundary clock can not be a slave only clock."
|
|
DEFVAL { false }
|
|
::= { ptpClockDataSetEntry 12 }
|
|
|
|
ptpClockLocalPriority OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is used in the alternate BMCA as a tie-breaker in the
|
|
dataset comparison algorithm, in the event that all other previous
|
|
attributes of the datasets being compared are equal."
|
|
REFERENCE "Section 6.3.1 and 6.3.2 of [2]"
|
|
DEFVAL { 128 }
|
|
::= { ptpClockDataSetEntry 13 }
|
|
|
|
ptpClockRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RowStatus for creating the entries into this table.
|
|
This object support only destroy and createAndGo values."
|
|
::= { ptpClockDataSetEntry 14 }
|
|
|
|
|
|
--
|
|
------- End of Ptp Default data set.
|
|
|
|
|
|
------- Begin of Ptp Specific data set
|
|
-- Contains global configuration/information
|
|
-- of a particular PTP clock.
|
|
--
|
|
|
|
ptpSpecificDataSetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PtpSpecificDataSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of vendor specific information about the PTP clock
|
|
for all domains."
|
|
::= { ptpSpecificDataSet 1 }
|
|
|
|
ptpSpecificDataSetEntry OBJECT-TYPE
|
|
SYNTAX PtpSpecificDataSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains vendor specific information for a particular PTP clock.
|
|
Where not otherwise specified, every object of this entry can
|
|
be modified with the conceptual row active."
|
|
INDEX { ptpClockDomainIndex,
|
|
ptpClockTypeIndex,
|
|
ptpClockInstanceIndex
|
|
}
|
|
::= { ptpSpecificDataSetTable 1 }
|
|
|
|
PtpSpecificDataSetEntry ::= SEQUENCE {
|
|
ptpAdminStatus INTEGER,
|
|
ptpStaticPortRole TruthValue,
|
|
ptpClockState ClockStateType,
|
|
ptpCompliance INTEGER
|
|
}
|
|
|
|
ptpAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down (1),
|
|
up (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object states if PTP is enabled or disabled for this PTP Clock
|
|
in order to switch on/off the PTP protocol."
|
|
DEFVAL { down }
|
|
::= { ptpSpecificDataSetEntry 1 }
|
|
|
|
ptpStaticPortRole OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object states that in the PTP Clock the A-BMCA is disabled and
|
|
it is working in Static PTP Port Role mode."
|
|
DEFVAL { false }
|
|
::= { ptpSpecificDataSetEntry 2 }
|
|
|
|
ptpClockState OBJECT-TYPE
|
|
SYNTAX ClockStateType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object shows the current state of the PTP Clock State Machine"
|
|
::= { ptpSpecificDataSetEntry 3 }
|
|
|
|
ptpCompliance OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
strictCompatibility (1),
|
|
looseCompatibility (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object states if the clock is strictly profile compliant. The
|
|
meaning of looseCompatibility is application dependent."
|
|
DEFVAL { looseCompatibility }
|
|
::= { ptpSpecificDataSetEntry 4 }
|
|
|
|
--
|
|
-- Ptp Specific alarms. Contains alarms of a particular PTP clock
|
|
-- .
|
|
|
|
ptpSpecificAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PtpSpecificAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of vendor specific information about the PTP clock
|
|
for all domains."
|
|
::= { ptpSpecificDataSet 2 }
|
|
|
|
ptpSpecificAlarmEntry OBJECT-TYPE
|
|
SYNTAX PtpSpecificAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains vendor specific alarm information for a particular PTP clock."
|
|
INDEX { ptpClockDomainIndex,
|
|
ptpClockTypeIndex,
|
|
ptpClockInstanceIndex
|
|
}
|
|
::= { ptpSpecificAlarmTable 1 }
|
|
|
|
PtpSpecificAlarmEntry ::= SEQUENCE {
|
|
ptpFreeRunningAlarm AlarmStatus,
|
|
ptpHoldoverInSpecAlarm AlarmStatus,
|
|
ptpHoldoverOutOfSpecAlarm AlarmStatus
|
|
}
|
|
|
|
ptpFreeRunningAlarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This alarm is raised when ptpClockState is set to freerun(1).
|
|
"
|
|
::= { ptpSpecificAlarmEntry 1 }
|
|
|
|
ptpHoldoverInSpecAlarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This alarm is raised when ptpClockState is set to
|
|
holdoverInSpec(4).
|
|
"
|
|
::= { ptpSpecificAlarmEntry 2 }
|
|
|
|
ptpHoldoverOutOfSpecAlarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This alarm is raised when ptpClockState is set to
|
|
holdoverOutOfSpec(5).
|
|
"
|
|
::= { ptpSpecificAlarmEntry 3 }
|
|
|
|
--
|
|
-- Ptp specific alarm severities.
|
|
--
|
|
|
|
ptpFreeRunningAlarmSeverityCode OBJECT-TYPE
|
|
SYNTAX AlarmSeverityCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the severity associated to
|
|
ptpFreeRunningAlarm and enables or disables the
|
|
sending of the SNMP Trap on the alarm status transition.
|
|
"
|
|
DEFVAL { warningTrapEnable }
|
|
::= { ptpSpecificDataSet 3 }
|
|
|
|
ptpHoldoverInSpecAlarmSeverityCode OBJECT-TYPE
|
|
SYNTAX AlarmSeverityCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the severity associated to
|
|
ptpHoldoverInSpecAlarm and enables or disables the
|
|
sending of the SNMP Trap on the alarm status transition.
|
|
"
|
|
DEFVAL { warningTrapEnable }
|
|
::= { ptpSpecificDataSet 4 }
|
|
|
|
ptpHoldoverOutOfSpecAlarmSeverityCode OBJECT-TYPE
|
|
SYNTAX AlarmSeverityCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the severity associated to
|
|
ptpHoldoverOutOfSpecAlarm and enables or disables the
|
|
sending of the SNMP Trap on the alarm status transition.
|
|
"
|
|
DEFVAL { majorTrapEnable }
|
|
::= { ptpSpecificDataSet 5 }
|
|
|
|
--
|
|
------- End of Ptp Specific data set.
|
|
|
|
|
|
------- Begin of Ptp Current data set.
|
|
-- Synchronization information of the PTP clock.
|
|
--
|
|
|
|
ptpCurrentDataSetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PtpCurrentDataSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the PTP clock Current Datasets for
|
|
all domains."
|
|
::= { ptpCurrentDataSet 1 }
|
|
|
|
ptpCurrentDataSetEntry OBJECT-TYPE
|
|
SYNTAX PtpCurrentDataSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Contains synchronization information on a particular domain."
|
|
INDEX { ptpClockDomainIndex,
|
|
ptpClockTypeIndex,
|
|
ptpClockInstanceIndex }
|
|
::= { ptpCurrentDataSetTable 1 }
|
|
|
|
PtpCurrentDataSetEntry ::= SEQUENCE {
|
|
ptpCurrentStepsRemoved Integer32,
|
|
ptpCurrentOffsetFromMaster ClockTimeInterval,
|
|
ptpCurrentMeanPathDelay ClockTimeInterval
|
|
}
|
|
|
|
ptpCurrentStepsRemoved OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the distance measured by the number of
|
|
Boundary clocks between the local clock and the Foreign master
|
|
as indicated in the stepsRemoved field of Announce messages.
|
|
Slave clock will update this field once port is selected as slave."
|
|
REFERENCE "1588 Version 2.0 Section 8.2.2.2 stepsRemoved"
|
|
::= { ptpCurrentDataSetEntry 1 }
|
|
|
|
ptpCurrentOffsetFromMaster OBJECT-TYPE
|
|
SYNTAX ClockTimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the current clock dataset ClockOffset
|
|
value. The value of the computation of the offset in time
|
|
between a slave and a master clock."
|
|
REFERENCE "1588 Version 2.0 Section 8.2.2.3 of [1]"
|
|
::= { ptpCurrentDataSetEntry 2 }
|
|
|
|
ptpCurrentMeanPathDelay OBJECT-TYPE
|
|
SYNTAX ClockTimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the current clock dataset
|
|
MeanPathDelay value.
|
|
The mean path delay between a pair of ports as measure by the
|
|
delay request-response mechanism."
|
|
REFERENCE "1588 Version 2.0 Section 8.2.2.4 mean path delay"
|
|
::= { ptpCurrentDataSetEntry 3 }
|
|
|
|
--
|
|
------- End of Ptp Current data set.
|
|
|
|
|
|
|
|
------- Begin of Ptp Parent data set.
|
|
-- Information about parent PTP clock.
|
|
--
|
|
|
|
ptpParentDataSetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PtpParentDataSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the PTP clock Parent Datasets for
|
|
all domains."
|
|
::= { ptpParentDataSet 1 }
|
|
|
|
ptpParentDataSetEntry OBJECT-TYPE
|
|
SYNTAX PtpParentDataSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains parent clock information on a particular domain. "
|
|
INDEX { ptpClockDomainIndex,
|
|
ptpClockTypeIndex,
|
|
ptpClockInstanceIndex }
|
|
::= { ptpParentDataSetTable 1 }
|
|
|
|
PtpParentDataSetEntry ::= SEQUENCE {
|
|
ptpParentClockIdentity OCTET STRING,
|
|
ptpParentPortNumber ClockPortNumber,
|
|
ptpParentGMClockIdentity OCTET STRING,
|
|
ptpParentGMClockClass ClockQualityClassType,
|
|
ptpParentGMClockAccuracy ClockQualityAccuracyType,
|
|
ptpParentGMClockOffsetScaledLogVariance Integer32,
|
|
ptpParentGMPriority1 Integer32,
|
|
ptpParentGMPriority2 Integer32
|
|
}
|
|
|
|
ptpParentClockIdentity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the clock identity of the port on the master that issues
|
|
sync messages used in synchronizing this clock. The initial value
|
|
of this field is the value of ptpClockIdentity"
|
|
REFERENCE "section 8.2.3.2 parentDS.parentPortIdentity of [1]"
|
|
::= { ptpParentDataSetEntry 1 }
|
|
|
|
ptpParentPortNumber OBJECT-TYPE
|
|
SYNTAX ClockPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the port number identity of the port on the master that issues
|
|
sync message used in synchronizing this clock. Combination of
|
|
ptpParentClockIdentity and ptpParentPortNumber gives the port identity
|
|
of the parent clock."
|
|
REFERENCE "section 8.2.3.2 parentDS.parentPortIdentity of [1]"
|
|
::= { ptpParentDataSetEntry 2 }
|
|
|
|
ptpParentGMClockIdentity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the clock identity attribute of the grand master clock.
|
|
The initial value is ptpClockIdentity."
|
|
REFERENCE "section 8.2.3.6 parentDS.grandmasterIdentity of [1]"
|
|
::= { ptpParentDataSetEntry 3 }
|
|
|
|
ptpParentGMClockClass OBJECT-TYPE
|
|
SYNTAX ClockQualityClassType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the clock class of the grandmaster. The
|
|
initialization value of this variable is ptpClockClass."
|
|
REFERENCE "section 8.2.3.7 parentDS.grandmasterClockQuality of [1]"
|
|
::= { ptpParentDataSetEntry 4 }
|
|
|
|
ptpParentGMClockAccuracy OBJECT-TYPE
|
|
SYNTAX ClockQualityAccuracyType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the clock accuracy of the grandmaster. The
|
|
initialization value of this variable is ptpClockAccuracy"
|
|
REFERENCE "section 8.2.3.7 parentDS.grandmasterClockQuality of [1]"
|
|
::= { ptpParentDataSetEntry 5 }
|
|
|
|
ptpParentGMClockOffsetScaledLogVariance OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the offset scaled log variance of the grandmaster. The
|
|
initialization value of this variable is
|
|
ptpClockOffsetScaledLogVariance"
|
|
REFERENCE "section 8.2.3.7 parentDS.grandmasterClockQuality of [1]"
|
|
::= { ptpParentDataSetEntry 6 }
|
|
|
|
ptpParentGMPriority1 OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the priority1 of the grandmaster clock. The
|
|
initialization value of this variable is ptpClockPriority1"
|
|
REFERENCE "section 8.2.3.8 parentDS.grandmasterPriority1 of [1]"
|
|
::= { ptpParentDataSetEntry 7 }
|
|
|
|
ptpParentGMPriority2 OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the priority2 of the grandmaster clock. The
|
|
initialization value of this variable is ptpClockPriority2"
|
|
REFERENCE "section 8.2.3.9 parentDS.grandmasterPriority2 of [1]"
|
|
::= { ptpParentDataSetEntry 8 }
|
|
|
|
--
|
|
------- End of Ptp Parent data set.
|
|
|
|
|
|
|
|
------- Begin of Ptp Time properties data set.
|
|
-- Global time properties of the clock.
|
|
--
|
|
|
|
ptpTimeDataSetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PtpTimeDataSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the PTP clock Timeproperties
|
|
Datasets for all domains."
|
|
::= { ptpTimePropertiesDataSet 1 }
|
|
|
|
ptpTimeDataSetEntry OBJECT-TYPE
|
|
SYNTAX PtpTimeDataSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains parent Time properties information of the
|
|
clock on a particular domain."
|
|
INDEX { ptpClockDomainIndex,
|
|
ptpClockTypeIndex,
|
|
ptpClockInstanceIndex }
|
|
::= { ptpTimeDataSetTable 1 }
|
|
|
|
PtpTimeDataSetEntry ::= SEQUENCE {
|
|
ptpTimeCurrentUTCOffset Integer32,
|
|
ptpTimeCurrentUTCOffsetValid TruthValue,
|
|
ptpTimeLeap59 TruthValue,
|
|
ptpTimeLeap61 TruthValue,
|
|
ptpTimeTimeTraceable TruthValue,
|
|
ptpTimeFrequencyTraceable TruthValue,
|
|
ptpTimescale TruthValue,
|
|
ptpTimeTimeSource ClockTimeSourceType
|
|
}
|
|
|
|
ptpTimeCurrentUTCOffset OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If systems epoch is the PTP epoch then this value indicates the offset
|
|
in seconds between TAI and UTC."
|
|
REFERENCE "section 8.2.4.2 timePropertiesDS.currentUtcOffset of [1]"
|
|
::= { ptpTimeDataSetEntry 1 }
|
|
|
|
ptpTimeCurrentUTCOffsetValid OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of this variable is TRUE if the ptpTimeCurrentUTCOffset is
|
|
known to be correct."
|
|
REFERENCE "section 8.2.4.3 timePropertiesDS.currentUtcOffsetValid of [1]"
|
|
::= { ptpTimeDataSetEntry 2 }
|
|
|
|
ptpTimeLeap59 OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the systems epoch is PTP epoch then TRUE value of this variable
|
|
indicates that the last minute of the current UTC day contains 59
|
|
seconds."
|
|
REFERENCE "section 8.2.4.4 timePropertiesDS.leap59 of [1]"
|
|
::= { ptpTimeDataSetEntry 3 }
|
|
|
|
ptpTimeLeap61 OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the systems epoch is PTP epoch then TRUE value of this variable
|
|
indicates that the last minute of the current UTC day contains 61
|
|
seconds."
|
|
REFERENCE "section 8.2.4.5 timePropertiesDS.leap61 of [1]"
|
|
::= { ptpTimeDataSetEntry 4 }
|
|
|
|
ptpTimeTimeTraceable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is TRUE if the timescale and value of
|
|
ptpTimeCurrentUTCOffset are traceable to a primary reference
|
|
otherwise, the value shall be FALSE."
|
|
REFERENCE "section 8.2.4.6 timePropertiesDS.timeTraceable of [1]"
|
|
::= { ptpTimeDataSetEntry 5 }
|
|
|
|
ptpTimeFrequencyTraceable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is TRUE if the frequecy determining the timescale is
|
|
traceable to a primary reference otherwise, the value shall be FALSE."
|
|
REFERENCE "section 8.2.4.7 timePropertiesDS.frequencyTraceable of [1]"
|
|
::= { ptpTimeDataSetEntry 6 }
|
|
|
|
ptpTimescale OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is TRUE if the clock timescale of the grandmaster clock
|
|
is PTP otherwise, the value shall be FALSE."
|
|
REFERENCE "section 8.2.4.8 timePropertiesDS.ptpTimescale of [1]"
|
|
::= { ptpTimeDataSetEntry 7 }
|
|
|
|
ptpTimeTimeSource OBJECT-TYPE
|
|
SYNTAX ClockTimeSourceType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the source of time used by the grandmaster clock. If the time
|
|
source is known at the time of initialization then the value will be set
|
|
to that otherwise the initial value is INTERNAL_OSCILLATOR(160)."
|
|
REFERENCE "section 8.2.4.9 timePropertiesDS.timeSource of [1]"
|
|
DEFVAL { internalOscillator }
|
|
::= { ptpTimeDataSetEntry 8 }
|
|
|
|
--
|
|
------- End of Ptp Time properties data set.
|
|
|
|
------- Begin of Ptp PPS and ToD properties data set.
|
|
--
|
|
|
|
ptpClockPPSDataSetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PtpClockPPSDataSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of information about the PTP clock PPS and ToD properties."
|
|
::= { ptpClockPPSDataSet 1 }
|
|
|
|
ptpClockPPSDataSetEntry OBJECT-TYPE
|
|
SYNTAX PtpClockPPSDataSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains PPS and ToD properties information of the
|
|
specific domain and clock on a specific PPS socket."
|
|
INDEX { ptpClockDomainIndex,
|
|
ptpClockTypeIndex,
|
|
ptpClockInstanceIndex,
|
|
ptpClockPPSInstanceIndex }
|
|
::= { ptpClockPPSDataSetTable 1 }
|
|
|
|
PtpClockPPSDataSetEntry ::= SEQUENCE {
|
|
ptpClockPPSInstanceIndex ClockPPSInstanceType,
|
|
ptpClockPPSInstanceCapability Unsigned32,
|
|
ptpClockPPSDirection INTEGER,
|
|
|
|
ptpClockPPSLabel DisplayString,
|
|
ptpClockPPSAdminStatus INTEGER,
|
|
ptpClockPPSOffsetEnabled TruthValue,
|
|
ptpClockPPSOffsetValue Integer32,
|
|
|
|
ptpClockToDLabel DisplayString,
|
|
ptpClockToDAdminStatus INTEGER,
|
|
ptpClockToDDelay Unsigned32,
|
|
ptpClockToDBaudrate Unsigned32,
|
|
ptpClockToDFormat PtpClockToDFormatType
|
|
}
|
|
|
|
|
|
ptpClockPPSInstanceIndex OBJECT-TYPE
|
|
SYNTAX ClockPPSInstanceType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the id of PPS interface socket.
|
|
It represents the id of ToD interface socket too."
|
|
DEFVAL { 0 }
|
|
::= { ptpClockPPSDataSetEntry 1 }
|
|
|
|
|
|
ptpClockPPSInstanceCapability OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is a bitmap and each bit represents
|
|
a specific capability of the PPS or ToD interface.
|
|
Bit 0 : 1 = the interface can be used either in input or in output
|
|
and the user can select the direction using ptpClockPPSDirection object;
|
|
0 = the interface can have one direction specified by the system,
|
|
in this case the ptpClockPPSDirection object is read only.
|
|
Bit 1 : 1 = the ToD interface allows more baudrate;
|
|
0 = the ToD interface allows one only baudrate, fixed by system. "
|
|
DEFVAL { 0 }
|
|
::= { ptpClockPPSDataSetEntry 2 }
|
|
|
|
|
|
ptpClockPPSDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
input (1),
|
|
output (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the direction (input or output)
|
|
of PPS signal and ToD data"
|
|
DEFVAL { 2 }
|
|
::= { ptpClockPPSDataSetEntry 3 }
|
|
|
|
|
|
ptpClockPPSLabel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the label as appears near the PPS signal socket"
|
|
DEFVAL { "PPS" }
|
|
::= { ptpClockPPSDataSetEntry 4 }
|
|
|
|
|
|
ptpClockPPSAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down (1),
|
|
up (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the administrive status of PPS interface and
|
|
specifies whether the node is enabled for PTP input/output
|
|
clocking using the PPS interface."
|
|
DEFVAL { down }
|
|
::= { ptpClockPPSDataSetEntry 5 }
|
|
|
|
|
|
ptpClockPPSOffsetEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies whether an offset is configured
|
|
in order to compensate for a known phase error
|
|
such as network asymmetry."
|
|
::= { ptpClockPPSDataSetEntry 6 }
|
|
|
|
|
|
ptpClockPPSOffsetValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the fixed offset signed value in nanoseconds
|
|
configured to be added for the PPS output or input."
|
|
::= { ptpClockPPSDataSetEntry 7 }
|
|
|
|
|
|
ptpClockToDLabel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the label as appears near the ToD socket"
|
|
DEFVAL { "ToD" }
|
|
::= { ptpClockPPSDataSetEntry 8 }
|
|
|
|
|
|
ptpClockToDAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
down (1),
|
|
up (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the administrive status of PPS interface and
|
|
specifies whether the ToD interface is enabled."
|
|
DEFVAL { down }
|
|
::= { ptpClockPPSDataSetEntry 9 }
|
|
|
|
|
|
ptpClockToDDelay OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..999999)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies microseconds of delay between PPS edge
|
|
and ToD data emitted, used only in output direction."
|
|
DEFVAL { 0 }
|
|
::= { ptpClockPPSDataSetEntry 10 }
|
|
|
|
|
|
ptpClockToDBaudrate OBJECT-TYPE
|
|
SYNTAX Unsigned32 (300|600|1200|1800|2400|4800|9600|19200|38400|57600|115200|230400)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the Baudrate of ToD signal in input or output direction."
|
|
DEFVAL { 9600 }
|
|
::= { ptpClockPPSDataSetEntry 11 }
|
|
|
|
|
|
ptpClockToDFormat OBJECT-TYPE
|
|
SYNTAX PtpClockToDFormatType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the format of ToD signal in input or output direction."
|
|
DEFVAL { telecomTimeEvent }
|
|
::= { ptpClockPPSDataSetEntry 12 }
|
|
|
|
--
|
|
------- End of Ptp PPS and ToD properties data set.
|
|
|
|
|
|
------- Begin of Ptp Port data set.
|
|
-- Configuration information of a particular PTP port.
|
|
--
|
|
|
|
ptpPortDataSetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PtpPortDataSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table Contains PTP configuration information
|
|
for a particular port of boundary or an ordinary clock"
|
|
::= { ptpPortDataSet 1 }
|
|
|
|
ptpPortDataSetEntry OBJECT-TYPE
|
|
SYNTAX PtpPortDataSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains PTP configuration information for a particular port.
|
|
Valid ptpPortIfIndex need to be given to make this entry active.
|
|
Where not otherwise specified, every object of this entry
|
|
can be modified with the conceptual row active."
|
|
INDEX { ptpClockDomainIndex,
|
|
ptpClockTypeIndex,
|
|
ptpClockInstanceIndex,
|
|
ptpPortIndex
|
|
}
|
|
::= { ptpPortDataSetTable 1 }
|
|
|
|
PtpPortDataSetEntry ::= SEQUENCE {
|
|
ptpPortIndex ClockPortNumber,
|
|
ptpPortClockIdentity OCTET STRING,
|
|
ptpPortIfIndex InterfaceIndex,
|
|
ptpPortStaticRole INTEGER,
|
|
ptpPortAdminStatus INTEGER,
|
|
ptpPortState ClockPortState,
|
|
ptpPortMinDelayReqInterval Integer32,
|
|
ptpPortLogAnnounceInterval Integer32,
|
|
ptpPortAnnounceReceiptTimeout Integer32,
|
|
ptpPortSyncInterval Integer32,
|
|
ptpPortDelayMechanism ClockMechanismType,
|
|
ptpPortVersionNumber Integer32,
|
|
ptpPortNotSlave TruthValue,
|
|
ptpPortLocalPriority Integer32,
|
|
ptpPortDestMacAddress INTEGER,
|
|
ptpPortTxAsymmetryCompensation Integer32,
|
|
ptpPortRxAsymmetryCompensation Integer32,
|
|
ptpPortRowStatus RowStatus
|
|
}
|
|
|
|
ptpPortIndex OBJECT-TYPE
|
|
SYNTAX ClockPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index value used to identify the port component on the device.
|
|
The value of this object is used as a port index to the
|
|
ptpPortConfigDataSetTable."
|
|
::= { ptpPortDataSetEntry 1 }
|
|
|
|
ptpPortClockIdentity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the clock Identity of the port"
|
|
REFERENCE "section 8.2.5.2.1 portDS.portIdentity of [1]"
|
|
::= { ptpPortDataSetEntry 2 }
|
|
|
|
ptpPortIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the index in ifTable of this port.
|
|
This object can't be modified."
|
|
::= { ptpPortDataSetEntry 3 }
|
|
|
|
ptpPortStaticRole OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
master (6),
|
|
passive (7),
|
|
slave (9)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Role of this port. This object forces the role of the port if
|
|
ptpStaticPortRole is true."
|
|
DEFVAL { master }
|
|
::= { ptpPortDataSetEntry 4}
|
|
|
|
ptpPortAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down (1),
|
|
up (2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Administrive status of the port. The value down turns off the PTP
|
|
protocol on the ethernet port."
|
|
DEFVAL { down }
|
|
::= { ptpPortDataSetEntry 5 }
|
|
|
|
ptpPortState OBJECT-TYPE
|
|
SYNTAX ClockPortState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This denotes the PTP State of the PTP port as computed by the PTP State
|
|
event machine.
|
|
|
|
initializing:
|
|
While a port is in the INITIALIZING state, the port initializes its data
|
|
sets, hardware, and communication facilities. No port of the clock shall
|
|
place any PTP messages on its communication path. If one port of a
|
|
boundary clock is in the INITIALIZING state, then all ports shall be in
|
|
the INITIALIZING state.
|
|
|
|
faulty:
|
|
The fault state of the protocol. A port in this state shall not place any
|
|
PTP messages except for management messages that are a required response
|
|
to another management message on its communication path.
|
|
|
|
disabled:
|
|
The port shall not place any messages on its communication path. In a
|
|
boundary clock, no activity at the port shall be allowed to affect the
|
|
activity at any other port of the boundary clock. A port in this state
|
|
shall discard all PTP received messages except for management messages.
|
|
|
|
listening:
|
|
The port is waiting for the announceReceiptTimeout to expire or to
|
|
receive an Announce message from a master. The purpose of this state is
|
|
to allow orderly addition of clocks to a domain. A port in this state
|
|
shall not place any PTP messages on its communication path except for
|
|
Pdelay_Req, Pdelay_Resp, Pdelay_Resp_Follow_Up, or signaling messages,
|
|
or management messages that are a required response to another
|
|
management message.
|
|
|
|
premaster:
|
|
The port shall behave in all respects as though it were in the MASTER
|
|
state except that it shall not place any messages on its communication
|
|
path except for Pdelay_Req, Pdelay_Resp, Pdelay_Resp_Follow_Up, signaling
|
|
or management messages.
|
|
|
|
master:
|
|
The port is behaving as a master port. It will periodically send announce
|
|
and sync messages.
|
|
|
|
passive:
|
|
The port shall not place any messages on its communication path except
|
|
for Pdelay_Req, Pdelay_Resp, Pdelay_Resp_Follow_Up, or signaling messages
|
|
or management messages that are a required response to another management
|
|
message.
|
|
|
|
uncalibrated:
|
|
This is a transient state to allow initialization of synchronization
|
|
servos, updating of data sets when a new master port has been selected,
|
|
and other implementation-specific activity.
|
|
|
|
slave:
|
|
The port is synchronizing to the selected master port."
|
|
REFERENCE "section 8.2.5.3.1 portDS.portState of [1]"
|
|
::= { ptpPortDataSetEntry 6 }
|
|
|
|
ptpPortMinDelayReqInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (-7..7)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the log to the base 2 of the delay request interval
|
|
in seconds. This speifies the time to the members devices to
|
|
send delay request messages when the port is in the master.
|
|
It specify the minimum permitted mean time interval between
|
|
successive Delay_Req messages, min delay request interval value is
|
|
a compromise between the fluctuation in link delay and startup time
|
|
and the communication and computation load imposed by transmission
|
|
of these messages."
|
|
REFERENCE "section 8.2.5.3.2 portDS.logMinDelayReqInterval of [1]"
|
|
DEFVAL { -4 }
|
|
::= { ptpPortDataSetEntry 7 }
|
|
|
|
ptpPortLogAnnounceInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (-3..6)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the log to the base 2 of the mean Announce message interval
|
|
in seconds."
|
|
REFERENCE "section 8.2.5.4.1 portDS.logAnnounceInterval of [1]"
|
|
DEFVAL { -3 }
|
|
::= { ptpPortDataSetEntry 8 }
|
|
|
|
ptpPortAnnounceReceiptTimeout OBJECT-TYPE
|
|
SYNTAX Integer32 (3..10)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the Announce receipt time out value.
|
|
This should be an integral multiple of announce interval
|
|
in seconds"
|
|
REFERENCE "section 8.2.5.4.2 portDS.announceReceiptTimeout of [1]"
|
|
DEFVAL { 3 }
|
|
::= { ptpPortDataSetEntry 9 }
|
|
|
|
ptpPortSyncInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (-7..0)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the logarithm to the base 2 of the sync message interval
|
|
in seconds"
|
|
REFERENCE "section 8.2.5.4.3 portDS.logSyncInterval of [1]"
|
|
DEFVAL { -4 }
|
|
::= { ptpPortDataSetEntry 10 }
|
|
|
|
ptpPortDelayMechanism OBJECT-TYPE
|
|
SYNTAX ClockMechanismType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This indicates the propagation delay measuring option used by the
|
|
port in computing meanpathDelay."
|
|
DEFVAL { e2e }
|
|
::= { ptpPortDataSetEntry 11 }
|
|
|
|
ptpPortVersionNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This indicates the PTP version in use on the port."
|
|
DEFVAL { 2 }
|
|
::= { ptpPortDataSetEntry 12 }
|
|
|
|
ptpPortNotSlave OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is used in the alternate BMCA to prevent that a port
|
|
can be placed in the SLAVE state."
|
|
REFERENCE "Section 6.3.1 and 6.3.2 of [2]"
|
|
DEFVAL { true }
|
|
::= { ptpPortDataSetEntry 13 }
|
|
|
|
ptpPortLocalPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is used in the alternate BMCA as a tie-breaker in the
|
|
dataset comparison algorithm, in the event that all other previous
|
|
attributes of the datasets being compared are equal."
|
|
REFERENCE "Section 6.3.1 and 6.3.2 of [2]"
|
|
DEFVAL { 128 }
|
|
::= { ptpPortDataSetEntry 14 }
|
|
|
|
ptpPortDestMacAddress OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
forwardable (1),
|
|
nonForwardable (2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is used in to select the destination MAC address
|
|
inserted in the outgoing packets:
|
|
forwardable: 01-1B-19-00-00-00
|
|
nonForwardable: 01-80-C2-00-00-0E
|
|
"
|
|
REFERENCE "Section 6.2.6 of [3]"
|
|
DEFVAL { nonForwardable }
|
|
::= { ptpPortDataSetEntry 15 }
|
|
|
|
ptpPortTxAsymmetryCompensation OBJECT-TYPE
|
|
SYNTAX Integer32 (-32768..32767)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is used to compensate in nanoseconds the asymmetric
|
|
delay. It works in TX direction."
|
|
DEFVAL { 0 }
|
|
::= { ptpPortDataSetEntry 16 }
|
|
|
|
ptpPortRxAsymmetryCompensation OBJECT-TYPE
|
|
SYNTAX Integer32 (-32768..32767)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is used to compensate in nanoseconds the asymmetric
|
|
delay. It works in RX direction."
|
|
DEFVAL { 0 }
|
|
::= { ptpPortDataSetEntry 17 }
|
|
|
|
ptpPortRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RowStatus for creating the entries into this table.
|
|
This object can't be modified."
|
|
::= { ptpPortDataSetEntry 18 }
|
|
|
|
--
|
|
-- Ptp Port alarms. Contains alarms of a particular PTP port
|
|
--
|
|
|
|
ptpPortAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PtpPortAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table Contains PTP alarm information
|
|
for a particular port of boundary or an ordinary clock."
|
|
::= { ptpPortDataSet 2 }
|
|
|
|
ptpPortAlarmEntry OBJECT-TYPE
|
|
SYNTAX PtpPortAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains PTP alarm information for a particular port."
|
|
INDEX { ptpClockDomainIndex,
|
|
ptpClockTypeIndex,
|
|
ptpClockInstanceIndex,
|
|
ptpPortIndex
|
|
}
|
|
::= { ptpPortAlarmTable 1 }
|
|
|
|
PtpPortAlarmEntry ::= SEQUENCE {
|
|
ptpPortFaultyAlarm AlarmStatus,
|
|
ptpPortInitializingAlarm AlarmStatus,
|
|
ptpPortUncalibratedAlarm AlarmStatus,
|
|
ptpPortListeningAlarm AlarmStatus,
|
|
ptpPortActiveStatus AlarmStatus
|
|
}
|
|
|
|
ptpPortFaultyAlarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This alarm is raised when ptpPortState is set to faulty(2)."
|
|
::= { ptpPortAlarmEntry 1 }
|
|
|
|
ptpPortInitializingAlarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This alarm is raised when ptpPortState is set to initializing(1).
|
|
"
|
|
::= { ptpPortAlarmEntry 2 }
|
|
|
|
ptpPortUncalibratedAlarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This alarm is raised when ptpPortState is set to uncalibrated(8).
|
|
"
|
|
::= { ptpPortAlarmEntry 3 }
|
|
|
|
ptpPortListeningAlarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This alarm is raised when ptpPortState is set to listening(4).
|
|
"
|
|
::= { ptpPortAlarmEntry 4 }
|
|
|
|
ptpPortActiveStatus OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This alarm is raised when ptpPortState is set to slave(9).
|
|
"
|
|
::= { ptpPortAlarmEntry 5 }
|
|
|
|
--
|
|
-- Ptp Radio Port alarms. Contains alarms of a Radio PTP port
|
|
--
|
|
|
|
ptpPortRadioAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PtpPortRadioAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table Contains PTP alarm information
|
|
for a radio port of boundary or an ordinary clock."
|
|
::= { ptpPortDataSet 3 }
|
|
|
|
ptpPortRadioAlarmEntry OBJECT-TYPE
|
|
SYNTAX PtpPortRadioAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains PTP alarm information for a radio port."
|
|
INDEX { ptpClockDomainIndex,
|
|
ptpClockTypeIndex,
|
|
ptpClockInstanceIndex,
|
|
ptpPortIndex
|
|
}
|
|
::= { ptpPortRadioAlarmTable 1 }
|
|
|
|
PtpPortRadioAlarmEntry ::= SEQUENCE {
|
|
ptpPortRadioCapacityAlarm AlarmStatus
|
|
}
|
|
|
|
ptpPortRadioCapacityAlarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This alarm is raised when the capacity of a radio link
|
|
is not big enough to transport PTP packets."
|
|
::= { ptpPortRadioAlarmEntry 1 }
|
|
|
|
--
|
|
-- Ptp Port alarm severities.
|
|
--
|
|
|
|
ptpPortFaultyAlarmSeverityCode OBJECT-TYPE
|
|
SYNTAX AlarmSeverityCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the severity associated to
|
|
ptpPortFaultyAlarm and enables or disables the
|
|
sending of the SNMP Trap on the alarm status transition.
|
|
"
|
|
DEFVAL { majorTrapEnable }
|
|
::= { ptpPortDataSet 4 }
|
|
|
|
ptpPortInitializingAlarmSeverityCode OBJECT-TYPE
|
|
SYNTAX AlarmSeverityCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the severity associated to
|
|
ptpPortInitializingAlarm and enables or disables the
|
|
sending of the SNMP Trap on the alarm status transition.
|
|
"
|
|
DEFVAL { warningTrapEnable }
|
|
::= { ptpPortDataSet 5 }
|
|
|
|
ptpPortUncalibratedAlarmSeverityCode OBJECT-TYPE
|
|
SYNTAX AlarmSeverityCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the severity associated to
|
|
ptpPortUncalibratedAlarm and enables or disables the
|
|
sending of the SNMP Trap on the alarm status transition.
|
|
"
|
|
DEFVAL { warningTrapEnable }
|
|
::= { ptpPortDataSet 6 }
|
|
|
|
ptpPortListeningAlarmSeverityCode OBJECT-TYPE
|
|
SYNTAX AlarmSeverityCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the severity associated to
|
|
ptpPortListeningAlarm and enables or disables the
|
|
sending of the SNMP Trap on the alarm status transition.
|
|
"
|
|
DEFVAL { warningTrapEnable }
|
|
::= { ptpPortDataSet 7 }
|
|
|
|
ptpPortActiveStatusSeverityCode OBJECT-TYPE
|
|
SYNTAX AlarmSeverityCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables or disables the sending of the SNMP Trap
|
|
on ptpPortActiveStatus transition.
|
|
"
|
|
DEFVAL { statusTrapEnable }
|
|
::= { ptpPortDataSet 8 }
|
|
|
|
ptpPortRadioCapacityAlarmSeverityCode OBJECT-TYPE
|
|
SYNTAX AlarmSeverityCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables or disables the sending of the SNMP Trap
|
|
on ptpPortRadioCapacityAlarm transition.
|
|
"
|
|
DEFVAL { majorTrapEnable }
|
|
::= { ptpPortDataSet 9 }
|
|
|
|
--
|
|
------- End of Ptp Port data set.
|
|
|
|
|
|
------- Begin of PTP Radio Asymmetry data set.
|
|
-- Configuration asymmetry of a specific Radio unit.
|
|
--
|
|
|
|
ptpRadioAsymmetryDataSetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PtpRadioAsymmetryDataSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table contains delay offset for asymmetries compensation for the Radio unit."
|
|
::= { ptpRadioAsymmetryDataSet 1 }
|
|
|
|
ptpRadioAsymmetryDataSetEntry OBJECT-TYPE
|
|
SYNTAX PtpRadioAsymmetryDataSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each ntry contains delay offset for asymmetries compensation for a specific Radio unit."
|
|
INDEX { ptpRadioBrIndex
|
|
}
|
|
::= { ptpRadioAsymmetryDataSetTable 1 }
|
|
|
|
PtpRadioAsymmetryDataSetEntry ::= SEQUENCE {
|
|
ptpRadioBrIndex Integer32,
|
|
ptpRadioOffset Integer32
|
|
}
|
|
|
|
|
|
ptpRadioBrIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the index in radioTable of this unit.
|
|
This object can't be modified."
|
|
::= { ptpRadioAsymmetryDataSetEntry 1 }
|
|
|
|
|
|
ptpRadioOffset OBJECT-TYPE
|
|
SYNTAX Integer32 (-32768..32767)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is an offset in nanoseconds for asymmetry compensation and
|
|
can have both positive and negative values."
|
|
DEFVAL { 0 }
|
|
::= { ptpRadioAsymmetryDataSetEntry 2 }
|
|
|
|
--
|
|
------- End of PTP Radio Asymmetry data set.
|
|
|
|
END
|
|
|
|
|