mibs/MIBS/telco-systems/binox/PRVT-TEMIB-ENTITY-MIB
2023-12-05 12:25:34 +01:00

210 lines
7.3 KiB
Plaintext

-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-TEMIB-ENTITY-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
PRVT-TEMIB-ENTITY-MIB DEFINITIONS ::= BEGIN
IMPORTS
mpls
FROM PRVT-SWITCH-MIB
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32
FROM SNMPv2-SMI
RowStatus, TEXTUAL-CONVENTION, TruthValue
FROM SNMPv2-TC;
prvtTeMibEntityMIB MODULE-IDENTITY
LAST-UPDATED "200712060000Z"
ORGANIZATION
"BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"The MIB module for management of TE-MIB entities."
REVISION "200712060000Z"
DESCRIPTION
"Initial."
::= { mpls 8 }
PrvtTeMibAdminStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The desired administrative state of a TE-MIB entity."
SYNTAX INTEGER { up(1), down(2) }
PrvtTeMibOperStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The current operational state of a TE-MIB entity."
SYNTAX INTEGER { up(1), down(2), goingUp(3), goingDown(4),
actFailed(5) }
PrvtTeMibEntityIndex ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"The index value identifying a TE-MIB entity."
SYNTAX Unsigned32
PrvtTeMibPartnerStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The state of a TE-MIB entity partner."
SYNTAX INTEGER { initial(0), activating(1), active(2),
deactivating(3), failedOver(4), failed(5),
unavailable(6) }
prvtTeMibEntityMIBObjects OBJECT IDENTIFIER
::= { prvtTeMibEntityMIB 1 }
prvtMplsTeMibEntityTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtMplsTeMibEntityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of TE-MIB entities."
::= { prvtTeMibEntityMIBObjects 1 }
prvtMplsTeMibEntityEntry OBJECT-TYPE
SYNTAX PrvtMplsTeMibEntityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry represents a TE-MIB entity."
INDEX { prvtMplsTeMibEntityIndex }
::= { prvtMplsTeMibEntityTable 1 }
PrvtMplsTeMibEntityEntry ::= SEQUENCE {
prvtMplsTeMibEntityIndex PrvtTeMibEntityIndex,
prvtMplsTeMibEntityRowStatus RowStatus,
prvtMplsTeMibDynFacilityBypass TruthValue
}
prvtMplsTeMibEntityIndex OBJECT-TYPE
SYNTAX PrvtTeMibEntityIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of this TE-MIB entity table entry. This is the
HAF entity index passed on the entity create parameters."
::= { prvtMplsTeMibEntityEntry 1 }
prvtMplsTeMibEntityRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status for the TE-MIB entity table entry, used to create
and destroy TE-MIB entities.
When prvtMplsTeMibEntityRowStatus is 'active' and
prvtMplsTeMibEntityAdminStatus is 'up' the TE-MIB entity is active
and only these two fields can be modified."
::= { prvtMplsTeMibEntityEntry 2 }
prvtMplsTeMibDynFacilityBypass OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object gives the user ability to globally enable/disable
automatically creation of bypass tunnels for all LSPs. Bypass
tunnels will be created on FRR tunnel request automatically.
The default value is true. The creation of Dynamic bypass tunnels
is enabled"
::= { prvtMplsTeMibEntityEntry 3 }
mplsTunnelHoldTimer OBJECT-TYPE
SYNTAX Unsigned32 (0..120)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines a period in seconds needed to wait before rebuilding backup
or primary tunnels if a frr condition occurs
Currently no more than 10 seconds are allowed"
::= { prvtTeMibEntityMIBObjects 2 }
prvtMplsTeMibEntityScalarTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtMplsTeMibEntityScalarEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mplsTeMibEntityScalarTable contains all MPLS Tunnel
scalars."
::= { prvtTeMibEntityMIBObjects 3 }
prvtMplsTeMibEntityScalarEntry OBJECT-TYPE
SYNTAX PrvtMplsTeMibEntityScalarEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The mplsTeMibEntityScalarTable contains all MPLS Tunnel
scalars."
INDEX { prvtMplsTeMibEntityIndex }
::= { prvtMplsTeMibEntityScalarTable 1 }
PrvtMplsTeMibEntityScalarEntry ::= SEQUENCE {
mplsTunnelConfigured Unsigned32,
mplsTunnelActive Unsigned32
}
mplsTunnelConfigured OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of tunnels configured on this device. A
tunnel is considered configured if the
mplsTunnelRowStatus is active(1)."
::= { prvtMplsTeMibEntityScalarEntry 1 }
mplsTunnelActive OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of tunnels active on this device. A
tunnel is considered active if the
mplsTunnelOperStatus is up(1)."
::= { prvtMplsTeMibEntityScalarEntry 2 }
END -- end of module PRVT-TEMIB-ENTITY-MIB.