mibs/MIBS/teleste/TELESTE-LUMINATO-MIB
2023-12-05 12:25:34 +01:00

4031 lines
84 KiB
Plaintext

--
-- TELESTE-LUMINATO-MIB.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 4.0 Build 349
-- Wednesday, September 30, 2009 at 14:12:58
--
-- TELESTE-LUMINATO-MIB.mib
--
-- *****************************************************************************
-- Copyright (c) 2000-2010 by:
--
-- Teleste Corporation
-- Seponkatu 1
-- FIN-20660 Littoinen, Finland
-- tel. +358 2 2605 611
-- url: http://www.teleste.com
--
-- Description: Objects for Luminato
--
-- Revision History:
-- -----------------
-- 1.2 16.02.2010 Sami Salo and Sergey Egorov
-- - Changed OID 1.3.6.1.4.1.3715.17.2 from 'monitor' to 'statusCode'
-- - Corrected types and ranges for PID, SID and TS IDs
-- - Minor cosmetic corrections
-- 1.1 30.09.2009 Rainer Salminen and Sami Salo
-- - Added monitor and alarm object tables
-- 1.0 19.02.2009 Sergey Egorov
-- - Initial release
-- ****************************************************************************
--
TELESTE-LUMINATO-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE
FROM RFC-1212
TimeTicks
FROM RFC1155-SMI
DisplayString
FROM RFC1213-MIB
Unsigned32
FROM SNMPv2-SMI
luminato
FROM TELESTE-ROOT-MIB
Float
FROM UCD-SNMP-MIB;
--
-- Node definitions
--
-- General information of device
-- 1.3.6.1.4.1.3715.17.1
general OBJECT IDENTIFIER ::= { luminato 1 }
-- 1.3.6.1.4.1.3715.17.1.1
deviceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The identification name ('aliasname') of the device"
::= { general 1 }
-- 1.3.6.1.4.1.3715.17.1.2
generalStatus OBJECT-TYPE
SYNTAX INTEGER
{
statusAlert(1),
statusCritical(2),
statusError(3),
statusWarning(4),
statusNotice(5),
statusInformational(6),
statusDebug(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"General status of device"
::= { general 2 }
-- 1.3.6.1.4.1.3715.17.1.3
redundancyStatus OBJECT-TYPE
SYNTAX INTEGER
{
redundancyStandalone(1),
redundancyMaster(16),
redundancyMasterHandover(24),
redundancyBackup(32),
redundancyBackupHandover(40),
redundancyError(64)
}
MAX-ACCESS read-only
STATUS optional
DESCRIPTION
"Status of device in 1+1 backup operation mode"
::= { general 3 }
-- 1.3.6.1.4.1.3715.17.1.10
hwSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device serial number"
::= { general 10 }
-- 1.3.6.1.4.1.3715.17.1.11
hwType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The hardware type name of the device"
::= { general 11 }
-- 1.3.6.1.4.1.3715.17.1.12
hwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device hardware version"
::= { general 12 }
-- 1.3.6.1.4.1.3715.17.1.13
swVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device running software version"
::= { general 13 }
-- 1.3.6.1.4.1.3715.17.1.14
upTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device uptime"
::= { general 14 }
-- 1.3.6.1.4.1.3715.17.1.15
cumulativeUptime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device cummulative uptime"
::= { general 15 }
-- 1.3.6.1.4.1.3715.17.2
statusCode OBJECT IDENTIFIER ::= { luminato 2 }
-- 1.3.6.1.4.1.3715.17.2.1
interfaceTypeTable OBJECT-TYPE
SYNTAX SEQUENCE OF InterfaceTypeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"InterfaceTypeTable lists possible interface types in the system."
::= { statusCode 1 }
-- 1.3.6.1.4.1.3715.17.2.1.1
interfaceTypeEntry OBJECT-TYPE
SYNTAX InterfaceTypeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each InterfaceTypeEntry describes type of the interface."
INDEX { interfaceTypeId }
::= { interfaceTypeTable 1 }
InterfaceTypeEntry ::=
SEQUENCE {
interfaceTypeId
INTEGER
}
-- 1.3.6.1.4.1.3715.17.2.1.1.1
interfaceTypeId OBJECT-TYPE
SYNTAX INTEGER
{
input(1),
output(2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interfacetype Id has two values input(1) and output(2). Values are used in other tables as index."
::= { interfaceTypeEntry 1 }
-- 1.3.6.1.4.1.3715.17.2.2
statusCodeDeviceTable OBJECT-TYPE
SYNTAX SEQUENCE OF StatusCodeDeviceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes monitorable objects of the device.
The objects may represents real objects or classes.
The monitoring system or user shall not poll this table to detect device state.
Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB.
In this case statusCodeDeviceTable shall be used to obtains text definition of alarm."
::= { statusCode 2 }
-- 1.3.6.1.4.1.3715.17.2.2.1
statusCodeDeviceEntry OBJECT-TYPE
SYNTAX StatusCodeDeviceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" "
INDEX { scdObjectId }
::= { statusCodeDeviceTable 1 }
StatusCodeDeviceEntry ::=
SEQUENCE {
scdObjectId
Unsigned32,
scdObjectValue
INTEGER,
scdObjectDescriptor
DisplayString,
scdObjectAlarmValue
INTEGER
}
-- 1.3.6.1.4.1.3715.17.2.2.1.1
scdObjectId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique identifier of the monitorable object.
"
::= { statusCodeDeviceEntry 1 }
-- 1.3.6.1.4.1.3715.17.2.2.1.2
scdObjectValue OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of the monitorable object.
The scdObjectDescriptor tells name, scale and unit of the object."
::= { statusCodeDeviceEntry 2 }
-- 1.3.6.1.4.1.3715.17.2.2.1.3
scdObjectDescriptor OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of the monitorable object.
Free text if object has two states
or
Format:
Name, Scale, Unit, [optional text]
------------------------------------
Example 1 (Analogue object):
'MainVoltage, 0.01, V'
Usage:
scdObjectId:7 (example)
scdObjectValue:2399
scdObjectDescriptor:'MainVoltage, 0.01, V'
means
Main voltage is 23.99 V
------------------------------------
Example 2 (Discrete object):
'TemperatureHigh, 1, high(2)/nominal(1), Alarm state of the temperature'
Usage:
scdObjectId:12 (example)
scdObjectValue:2
means
Temperature is in high alarm state.
------------------------------------
"
::= { statusCodeDeviceEntry 3 }
-- 1.3.6.1.4.1.3715.17.2.2.1.4
scdObjectAlarmValue OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When the object has this value it is in the alarm state.
One object id can have only one alarm state.
If more alarm states exist then new associated object needs to be created.
Note that alarm state value can have only discrete values.
If the value is zero then there is no alarm for this object.
Example:
TemperatureHigh object can have values high(2) or nominal(1).
Alarm monitoring for this object is triggered by setting dmObjectAlarmValue
to value 2 meaning high(2).
How the alarm processing is done is out of scope of this MIB.
"
::= { statusCodeDeviceEntry 4 }
-- 1.3.6.1.4.1.3715.17.2.3
statusCodeModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF StatusCodeModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes monitorable objects per module inside the device.
The objects may represents real objects or classes.
The monitoring system or user shall not poll this table to detect device state.
Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB.
In this case statusCodeModuleTable shall be used to obtains text definition of alarm."
::= { statusCode 3 }
-- 1.3.6.1.4.1.3715.17.2.3.1
statusCodeModuleEntry OBJECT-TYPE
SYNTAX StatusCodeModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" "
INDEX { scmModuleId, scmObjectId }
::= { statusCodeModuleTable 1 }
StatusCodeModuleEntry ::=
SEQUENCE {
scmModuleId
INTEGER,
scmObjectId
Unsigned32,
scmObjectValue
INTEGER,
scmObjectDescriptor
DisplayString,
scmObjectAlarmValue
INTEGER
}
-- 1.3.6.1.4.1.3715.17.2.3.1.1
scmModuleId OBJECT-TYPE
SYNTAX INTEGER (1..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module Id within the device (usually slot number)."
::= { statusCodeModuleEntry 1 }
-- 1.3.6.1.4.1.3715.17.2.3.1.2
scmObjectId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique identifier of the monitorable object within the module."
::= { statusCodeModuleEntry 2 }
-- 1.3.6.1.4.1.3715.17.2.3.1.3
scmObjectValue OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of the monitorable object.
The scmObjectDescriptor tells name, scale and unit of the object."
::= { statusCodeModuleEntry 3 }
-- 1.3.6.1.4.1.3715.17.2.3.1.4
scmObjectDescriptor OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of the monitorable object.
See scdObjectDescriptor for format, example and usage.
"
::= { statusCodeModuleEntry 4 }
-- 1.3.6.1.4.1.3715.17.2.3.1.5
scmObjectAlarmValue OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"See scdObjectAlarmValue for format, example and usage.
"
::= { statusCodeModuleEntry 5 }
-- 1.3.6.1.4.1.3715.17.2.4
statusCodeInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF StatusCodeInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes monitorable objects per interface per module.
The objects may represents real objects or classes.
The monitoring system or user shall not poll this table to detect device state.
Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB.
In this case statusCodeInterfaceTable shall be used to obtains text definition of alarm."
::= { statusCode 4 }
-- 1.3.6.1.4.1.3715.17.2.4.1
statusCodeInterfaceEntry OBJECT-TYPE
SYNTAX StatusCodeInterfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" "
INDEX { interfaceTypeId, scmModuleId, sciInterfaceId, sciObjectId }
::= { statusCodeInterfaceTable 1 }
StatusCodeInterfaceEntry ::=
SEQUENCE {
sciInterfaceId
INTEGER,
sciObjectId
Unsigned32,
sciObjectValue
INTEGER,
sciObjectDescriptor
DisplayString,
sciObjectAlarmValue
INTEGER
}
-- 1.3.6.1.4.1.3715.17.2.4.1.1
sciInterfaceId OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique interface Id within the module (e.g. RF connector number)."
::= { statusCodeInterfaceEntry 1 }
-- 1.3.6.1.4.1.3715.17.2.4.1.2
sciObjectId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique identifier of the monitorable object within the interface."
::= { statusCodeInterfaceEntry 2 }
-- 1.3.6.1.4.1.3715.17.2.4.1.3
sciObjectValue OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of the monitorable object.
The sciObjectDescriptor tells name, scale and unit of the object."
::= { statusCodeInterfaceEntry 3 }
-- 1.3.6.1.4.1.3715.17.2.4.1.4
sciObjectDescriptor OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of the monitorable object.
See scdObjectDescriptor for format, example and usage.
"
::= { statusCodeInterfaceEntry 4 }
-- 1.3.6.1.4.1.3715.17.2.4.1.5
sciObjectAlarmValue OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"See dmObjectAlarmValue for format, example and usage.
"
::= { statusCodeInterfaceEntry 5 }
-- 1.3.6.1.4.1.3715.17.2.5
statusCodeTransportStreamTable OBJECT-TYPE
SYNTAX SEQUENCE OF StatusCodeTransportStreamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes monitorable objects of each transport stream.
The objects may represents real objects or classes.
The monitoring system or user shall not poll this table to detect device state.
Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB.
In this case statusCodeTransportStreamTable shall be used to obtains text definition of alarm."
::= { statusCode 5 }
-- 1.3.6.1.4.1.3715.17.2.5.1
statusCodeTransportStreamEntry OBJECT-TYPE
SYNTAX StatusCodeTransportStreamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" "
INDEX { interfaceTypeId, scmModuleId, sciInterfaceId, sctsTransportStreamId, sctsObjectId
}
::= { statusCodeTransportStreamTable 1 }
StatusCodeTransportStreamEntry ::=
SEQUENCE {
sctsTransportStreamId
INTEGER,
sctsObjectId
Unsigned32,
sctsObjectValue
INTEGER,
sctsObjectDescriptor
DisplayString,
sctsObjectAlarmValue
INTEGER
}
-- 1.3.6.1.4.1.3715.17.2.5.1.1
sctsTransportStreamId OBJECT-TYPE
SYNTAX INTEGER (1..8192)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique transport stream id inside the interface."
::= { statusCodeTransportStreamEntry 1 }
-- 1.3.6.1.4.1.3715.17.2.5.1.2
sctsObjectId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique identifier of the monitorable object."
::= { statusCodeTransportStreamEntry 2 }
-- 1.3.6.1.4.1.3715.17.2.5.1.3
sctsObjectValue OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of the monitorable object.
The sctsObjectDescriptor tells name, scale and unit of the object."
::= { statusCodeTransportStreamEntry 3 }
-- 1.3.6.1.4.1.3715.17.2.5.1.4
sctsObjectDescriptor OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of the monitorable object.
See dmObjectDescriptor for format, example and usage.
"
::= { statusCodeTransportStreamEntry 4 }
-- 1.3.6.1.4.1.3715.17.2.5.1.5
sctsObjectAlarmValue OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"See scdObjectAlarmValue for format, example and usage.
"
::= { statusCodeTransportStreamEntry 5 }
-- 1.3.6.1.4.1.3715.17.2.6
statusCodeServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF StatusCodeServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes monitorable objects of each service.
The objects may represents real objects or classes.
The monitoring system or user shall not poll this table to detect device state.
Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB.
In this case statusCodeServiceTable shall be used to obtains text definition of alarm."
::= { statusCode 6 }
-- 1.3.6.1.4.1.3715.17.2.6.1
statusCodeServiceEntry OBJECT-TYPE
SYNTAX StatusCodeServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" "
INDEX { interfaceTypeId, scmModuleId, sciInterfaceId, sctsTransportStreamId, scsSID,
scsObjectId }
::= { statusCodeServiceTable 1 }
StatusCodeServiceEntry ::=
SEQUENCE {
scsSID
INTEGER,
scsObjectId
Unsigned32,
scsObjectValue
INTEGER,
scsObjectDescriptor
DisplayString,
scsServiceName
DisplayString,
scsObjectAlarmValue
INTEGER
}
-- 1.3.6.1.4.1.3715.17.2.6.1.1
scsSID OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique service id number inside the transport stream."
::= { statusCodeServiceEntry 1 }
-- 1.3.6.1.4.1.3715.17.2.6.1.2
scsObjectId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique identifier of the monitorable object."
::= { statusCodeServiceEntry 2 }
-- 1.3.6.1.4.1.3715.17.2.6.1.3
scsObjectValue OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of the monitorable object.
The scsObjectDescriptor tells name, scale and unit of the object."
::= { statusCodeServiceEntry 3 }
-- 1.3.6.1.4.1.3715.17.2.6.1.4
scsObjectDescriptor OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of the monitorable object.
See scdObjectDescriptor for format, example and usage.
"
::= { statusCodeServiceEntry 4 }
-- 1.3.6.1.4.1.3715.17.2.6.1.5
scsServiceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the service."
::= { statusCodeServiceEntry 5 }
-- 1.3.6.1.4.1.3715.17.2.6.1.6
scsObjectAlarmValue OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"See scdObjectAlarmValue for format, example and usage.
"
::= { statusCodeServiceEntry 6 }
-- 1.3.6.1.4.1.3715.17.2.7
statusCodePidTable OBJECT-TYPE
SYNTAX SEQUENCE OF StatusCodePidEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists monitorable objects of each PID.
The objects may represents real objects or classes.
The monitoring system or user shall not poll this table to detect device state.
Instead - user shall wait for traps or poll currentAlarmTable(1.3.6.1.4.1.5591.1.1.2) from SCTE-HMS-PROPERTY-MIB.
In this case statusCodePidTable shall be used to obtains text definition of alarm."
::= { statusCode 7 }
-- 1.3.6.1.4.1.3715.17.2.7.1
statusCodePidEntry OBJECT-TYPE
SYNTAX StatusCodePidEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" "
INDEX { interfaceTypeId, scmModuleId, sciInterfaceId, sctsTransportStreamId, scpPID,
scpObjectId }
::= { statusCodePidTable 1 }
StatusCodePidEntry ::=
SEQUENCE {
scpPID
INTEGER,
scpObjectId
Unsigned32,
scpObjectValue
INTEGER,
scpObjectDescriptor
DisplayString,
scpObjectAlarmValue
INTEGER
}
-- 1.3.6.1.4.1.3715.17.2.7.1.1
scpPID OBJECT-TYPE
SYNTAX INTEGER (0..8191)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique PID value inside the transport stream."
::= { statusCodePidEntry 1 }
-- 1.3.6.1.4.1.3715.17.2.7.1.2
scpObjectId OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique identifier of the monitorable object."
::= { statusCodePidEntry 2 }
-- 1.3.6.1.4.1.3715.17.2.7.1.3
scpObjectValue OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of the monitorable object.
The scpObjectDescriptor tells name, scale and unit of the object."
::= { statusCodePidEntry 3 }
-- 1.3.6.1.4.1.3715.17.2.7.1.4
scpObjectDescriptor OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of the monitorable object.
See scdObjectDescriptor for format, example and usage.
"
::= { statusCodePidEntry 4 }
-- 1.3.6.1.4.1.3715.17.2.7.1.5
scpObjectAlarmValue OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"See scdObjectAlarmValue for format, example and usage.
"
::= { statusCodePidEntry 5 }
-- 1.3.6.1.4.1.3715.17.3
interface OBJECT IDENTIFIER ::= { luminato 3 }
-- 1.3.6.1.4.1.3715.17.3.1
ifExtTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { interface 1 }
-- 1.3.6.1.4.1.3715.17.3.1.1
ifExtEntry OBJECT-TYPE
SYNTAX IfExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { INTEGER }
::= { ifExtTable 1 }
IfExtEntry ::=
SEQUENCE {
ifExtIndex
INTEGER,
ifExtName
DisplayString,
ifExtModule
INTEGER,
ifExtPhysInterface
INTEGER,
ifExtLogiInterface
INTEGER,
ifExtDirection
INTEGER
}
-- 1.3.6.1.4.1.3715.17.3.1.1.1
ifExtIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique index for an interface.
The index is of following format: SDPPVVVV, where:
- S = Slot number
- D = input(1) / output(2)
- PP = Physical interface number
- VVVV = Virtual interface number"
::= { ifExtEntry 1 }
-- 1.3.6.1.4.1.3715.17.3.1.1.2
ifExtName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for the interface."
::= { ifExtEntry 2 }
-- 1.3.6.1.4.1.3715.17.3.1.1.3
ifExtModule OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of the physical module or slot housing the interface."
::= { ifExtEntry 3 }
-- 1.3.6.1.4.1.3715.17.3.1.1.4
ifExtPhysInterface OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical interface number."
::= { ifExtEntry 4 }
-- 1.3.6.1.4.1.3715.17.3.1.1.5
ifExtLogiInterface OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical interface number."
::= { ifExtEntry 5 }
-- 1.3.6.1.4.1.3715.17.3.1.1.6
ifExtDirection OBJECT-TYPE
SYNTAX INTEGER
{
input(1),
output(2),
both(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Direction for the data going through the interface."
::= { ifExtEntry 6 }
-- Signal physical level
-- 1.3.6.1.4.1.3715.17.3.2
signalPhysTable OBJECT-TYPE
SYNTAX SEQUENCE OF SignalPhysEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { interface 2 }
-- 1.3.6.1.4.1.3715.17.3.2.1
signalPhysEntry OBJECT-TYPE
SYNTAX SignalPhysEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { ifExtIndex }
::= { signalPhysTable 1 }
SignalPhysEntry ::=
SEQUENCE {
signalSnr
INTEGER,
signalSnrMin
INTEGER,
signalSnrMax
INTEGER,
signalCcErrors
INTEGER,
signalBer
Float,
signalVber
Float
}
-- 1.3.6.1.4.1.3715.17.3.2.1.2
signalSnr OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Recent signal to noise ratio in 1/10th of dB."
::= { signalPhysEntry 2 }
-- 1.3.6.1.4.1.3715.17.3.2.1.3
signalSnrMin OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Lowest measured SNR value since last device startup or last counter reset."
::= { signalPhysEntry 3 }
-- 1.3.6.1.4.1.3715.17.3.2.1.4
signalSnrMax OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Highest measured SNR value since last device startup or last counter reset."
::= { signalPhysEntry 4 }
-- 1.3.6.1.4.1.3715.17.3.2.1.5
signalCcErrors OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of continuity errors since last device startup or last counter reset."
::= { signalPhysEntry 5 }
-- 1.3.6.1.4.1.3715.17.3.2.1.6
signalBer OBJECT-TYPE
SYNTAX Float
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Calculated bit error ratio of the signal."
::= { signalPhysEntry 6 }
-- 1.3.6.1.4.1.3715.17.3.2.1.7
signalVber OBJECT-TYPE
SYNTAX Float
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Calculated Viterbi bit error ratio of the signal."
::= { signalPhysEntry 7 }
-- transfer statistics
-- 1.3.6.1.4.1.3715.17.3.3
transferTable OBJECT-TYPE
SYNTAX SEQUENCE OF TransferEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { interface 3 }
-- 1.3.6.1.4.1.3715.17.3.3.1
transferEntry OBJECT-TYPE
SYNTAX TransferEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { ifExtIndex }
::= { transferTable 1 }
TransferEntry ::=
SEQUENCE {
transBitrate
INTEGER,
transBitrateMin
INTEGER,
transBitrateMax
INTEGER
}
-- 1.3.6.1.4.1.3715.17.3.3.1.2
transBitrate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Recent measured bitrate of the interface in kilobits per second."
::= { transferEntry 2 }
-- 1.3.6.1.4.1.3715.17.3.3.1.3
transBitrateMin OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Lowest measured bitrate since last device startup or last counter reset.
Writing clears the counter."
::= { transferEntry 3 }
-- 1.3.6.1.4.1.3715.17.3.3.1.4
transBitrateMax OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Highest measured bitrate since last device startup or last counter reset.
Writing clears the counter."
::= { transferEntry 4 }
-- ProMpegFec interface related data
-- 1.3.6.1.4.1.3715.17.3.20
proMpegFecTable OBJECT-TYPE
SYNTAX SEQUENCE OF ProMpegFecEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { interface 20 }
-- 1.3.6.1.4.1.3715.17.3.20.1
proMpegFecEntry OBJECT-TYPE
SYNTAX ProMpegFecEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { ifExtIndex }
::= { proMpegFecTable 1 }
ProMpegFecEntry ::=
SEQUENCE {
fecValidPkts
Counter32,
fecUncorrectedPkts
Counter32,
fecCorrectedPkts
Counter32,
fecDuplicatePkts
Counter32,
fecReorderedPkts
Counter32,
fecIncorrectSeqNumbers
Counter32,
fecDiscontinuities
Counter32
}
-- 1.3.6.1.4.1.3715.17.3.20.1.1
fecValidPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of media stream packets received.
Writing any value in this oid will clear all ProMpegFec related counters on
the current interface."
::= { proMpegFecEntry 1 }
-- 1.3.6.1.4.1.3715.17.3.20.1.2
fecUncorrectedPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of missing media stream packets after FEC decoding.
Writing any value in this oid will clear all ProMpegFec related counters on
the current interface."
::= { proMpegFecEntry 2 }
-- 1.3.6.1.4.1.3715.17.3.20.1.3
fecCorrectedPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of corrected packets after FEC decoding.
Writing any value in this oid will clear all ProMpegFec related counters on
the current interface."
::= { proMpegFecEntry 3 }
-- 1.3.6.1.4.1.3715.17.3.20.1.4
fecDuplicatePkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of duplicate packets received. Defined as a received packet with
the same RTP sequence number as any of the packets already in the decoding
buffer. All duplicate packets are automatically discarded and do not cause
missing packets or duplicates to the output stream.
Writing any value in this oid will clear all ProMpegFec related counters on
the current interface."
::= { proMpegFecEntry 4 }
-- 1.3.6.1.4.1.3715.17.3.20.1.5
fecReorderedPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of reordered packets received. Defined as a received packet which
RTP sequence number is smaller than the highest RTP sequence number already
received, excluding duplicate packets and packets which are out of the
decoding buffer range. These packets will be re-ordered and do not cause
missing packets to the output stream.
Writing any value in this oid will clear all ProMpegFec related counters on
the current interface."
::= { proMpegFecEntry 5 }
-- 1.3.6.1.4.1.3715.17.3.20.1.6
fecIncorrectSeqNumbers OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of received media packets that have RTP sequence number out of
decoding buffer range. All these packet are discarded. If 10 consecutive
packets are out of range then decoding buffer is flushed and re-initialised
i.e. all packets in the buffer are discarded. Incorrect sequence numbers
counter will not be incremented if decoding buffer has been flushed.
Writing any value in this oid will clear all ProMpegFec related counters on
the current interface."
::= { proMpegFecEntry 6 }
-- 1.3.6.1.4.1.3715.17.3.20.1.7
fecDiscontinuities OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of RTP sequence number discontinuities after FEC decoding. Discontinuity
is detected when the sequence number of received RTP packet (after decoding) is
not equal to sequence number of previous packet. Discontinuities are typically
detected when there are uncorrected packets in the stream, or when there are
brief interruptions in the stream (in range of about 1-20 seconds). Also abrupt
change of stream source will be counted as discontinuity because of jump in RTP
sequence numbers.
Writing any value in this oid will clear all ProMpegFec related counters on
the current interface."
::= { proMpegFecEntry 7 }
-- Input service information
-- 1.3.6.1.4.1.3715.17.3.4
inputServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF InputServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { interface 4 }
-- 1.3.6.1.4.1.3715.17.3.4.1
inputServiceEntry OBJECT-TYPE
SYNTAX InputServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { ifExtIndex }
::= { inputServiceTable 1 }
InputServiceEntry ::=
SEQUENCE {
iSID
INTEGER,
iServiceName
DisplayString,
iServiceBitrate
INTEGER
}
-- 1.3.6.1.4.1.3715.17.3.4.1.2
iSID OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique service id number inside the transport stream."
::= { inputServiceEntry 2 }
-- 1.3.6.1.4.1.3715.17.3.4.1.3
iServiceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the service."
::= { inputServiceEntry 3 }
-- 1.3.6.1.4.1.3715.17.3.4.1.4
iServiceBitrate OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The bitrate of service"
::= { inputServiceEntry 4 }
-- Output service information
-- 1.3.6.1.4.1.3715.17.3.5
outputServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF OutputServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { interface 5 }
-- 1.3.6.1.4.1.3715.17.3.5.1
outputServiceEntry OBJECT-TYPE
SYNTAX OutputServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { ifExtIndex }
::= { outputServiceTable 1 }
OutputServiceEntry ::=
SEQUENCE {
oSID
INTEGER,
oServiceName
DisplayString,
oServiceBitrate
INTEGER
}
-- 1.3.6.1.4.1.3715.17.3.5.1.2
oSID OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique service id number inside the transport stream."
::= { outputServiceEntry 2 }
-- 1.3.6.1.4.1.3715.17.3.5.1.2
oServiceName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the service."
::= { outputServiceEntry 3 }
-- 1.3.6.1.4.1.3715.17.3.5.1.3
oServiceBitrate OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The bitrate of service"
::= { outputServiceEntry 4 }
----------------------------------------------------------------------
-- 1.3.6.1.4.1.3715.17.4
notifications OBJECT IDENTIFIER ::= { luminato 4 }
-- 1.3.6.1.4.1.3715.17.5
statusFlags OBJECT IDENTIFIER ::= { luminato 5 }
-- 1.3.6.1.4.1.3715.17.5.2
moduleStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModuleStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " "
::= { statusFlags 2 }
-- 1.3.6.1.4.1.3715.17.5.2.1
moduleStatusEntry OBJECT-TYPE
SYNTAX ModuleStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " "
INDEX { moduleId }
::= { moduleStatusTable 1 }
ModuleStatusEntry ::=
SEQUENCE {
moduleId
INTEGER,
modulePidConflictStatus
INTEGER,
moduleTemperatureHigh
INTEGER,
moduleTemperatureLow
INTEGER,
modulePidCapaStatus
INTEGER,
modulePsisiCaptureCapaStatus
INTEGER,
moduleSidAllocStatus
INTEGER,
moduleCaDetectStatus
INTEGER,
moduleDetectStatus
INTEGER,
moduleVoltageHigh
INTEGER,
moduleVoltageLow
INTEGER,
moduleCurrentHigh
INTEGER,
moduleCurrentLow
INTEGER,
moduleDaemonInitStatus
INTEGER,
moduleDriverStatus
INTEGER,
moduleHwStatus
INTEGER,
moduleFanStatus
INTEGER,
modulePowerSourceStatus
INTEGER,
modulePsuOverloadStatus
INTEGER,
moduleBootupProgressStatus
INTEGER,
moduleBootupRetryStatus
INTEGER,
moduleBootupStatus
INTEGER,
moduleShutdownProgressStatus
INTEGER,
moduleConnStatus
INTEGER,
moduleCompatStatus
INTEGER,
moduleUpcPowerLow
INTEGER,
moduleUpcPowerHigh
INTEGER,
moduleCalibrDataStatus
INTEGER,
moduleCalibrDataCheckStatus
INTEGER,
moduleDescrStatus
INTEGER,
moduleBackupStatus
INTEGER,
moduleNitOutputsStatus
INTEGER,
moduleNitSelectionStatus
INTEGER,
moduleNitConfChangeStatus
INTEGER,
moduleNitDataQueryStatus
INTEGER,
moduleNitWizardStatus
INTEGER,
moduleQamFreqStatus
INTEGER,
moduleOutputSidStatus
INTEGER,
moduleConfStatus
INTEGER,
moduleFreqStatus
INTEGER,
moduleOutputPowerStatus
INTEGER,
moduleSymrateStatus
INTEGER,
moduleChanDistStatus
INTEGER,
moduleLnbVoltStatus
INTEGER,
moduleFecRateStatus
INTEGER,
moduleLnbCurrStatus
INTEGER,
moduleFreqOffsetStatus
INTEGER,
moduleDescrRestartStatus
INTEGER,
moduleCamRestartStatus
INTEGER,
moduleEcmgStatus
INTEGER,
moduleEcmStreamStatus
INTEGER,
moduleEmmStatus
INTEGER,
moduleEmmStreamStatus
INTEGER,
moduleEcmgConnStatus
INTEGER,
moduleEmmConnStatus
INTEGER,
moduleEcmgSpareStatus
INTEGER,
moduleBootloaderAvailStatus
INTEGER,
moduleBl1UpdateProgStatus
INTEGER,
moduleBl2UpdateProgStatus
INTEGER,
moduleBl1UpdateStatus
INTEGER,
moduleBl2UpdateStatus
INTEGER,
moduleActiveBackupStatus
INTEGER,
moduleConfProgressStatus
INTEGER,
modulePresenceStatus
INTEGER,
moduleProcessRestartStatus
INTEGER,
moduleBackupLicenseStatus
INTEGER,
modulePsisiEditorLicenseStatus
INTEGER,
moduleMuxLicenseStatus
INTEGER,
moduleDemuxLicenseStatus
INTEGER,
moduleDvbLicenseStatus
INTEGER,
moduleMsdLicenseStatus
INTEGER,
moduleDvbs2LicenseStatus
INTEGER,
moduleDvbt2LicenseStatus
INTEGER,
moduleScsLicenseStatus
INTEGER,
moduleCliLoginStatus
INTEGER,
moduleRedunActivationStatus
INTEGER,
moduleExtioPinSignalingStatus
INTEGER,
moduleBackupPsuStatus
INTEGER,
moduleIntrusionStatus
INTEGER,
moduleRedunStatus
INTEGER,
moduleBackupHwStatus
INTEGER,
moduleSwUpdateProgress
INTEGER,
moduleSwUpdateStatus
INTEGER,
moduleEitLicenseStatus
INTEGER,
moduleDescramblingStatus
INTEGER,
moduleDvbTimeStatus
INTEGER,
moduleTunerDcFeedStatus
INTEGER,
moduleTunerPlpSelectionReqStatus
INTEGER,
moduleTunerPlpStatus
INTEGER,
moduleTunerHierarchyStatus
INTEGER,
moduleEcmStatus
INTEGER,
moduleScramConflictStatus
INTEGER,
moduleScramSharedStatus
INTEGER,
moduleBackupVoltageHigh
INTEGER,
moduleBackupVoltageLow
INTEGER,
moduleSdtTableStatus
INTEGER,
moduleDescramblingRestart
INTEGER,
moduleCaModuleRestart
INTEGER,
moduleCaMenuStatus
INTEGER,
moduleInvalidCamRouting
INTEGER,
moduleNitSidConflict
INTEGER,
moduleLicenseMissingFEC
INTEGER,
moduleFecCorrectionStatus
INTEGER,
moduleFecPacketDropStatus
INTEGER,
moduleFecMediaPktsStatus
INTEGER,
moduleSfpLinkStatus
INTEGER,
moduleBackupSyncModeOff
INTEGER,
moduleBackupSyncModeManual
INTEGER,
moduleBackupSyncModeAuto
INTEGER,
moduleBackupSyncConfStatus
INTEGER,
moduleBackupSyncStatus
INTEGER,
moduleBackupSyncSwCompatibility
INTEGER,
moduleBackupSyncHwCompatibility
INTEGER,
moduleBackupSyncConfFaultStatus
INTEGER,
moduleBackupSyncConnectionStatus
INTEGER,
moduleBackupSyncFromBackupStatus
INTEGER,
moduleBackupSyncRebootStatus
INTEGER,
moduleBackupSyncLicenseCompatStatus
INTEGER,
moduleBackupSyncLicenseCompareStatus
INTEGER,
moduleDeviceFirstBootStatus
INTEGER,
modulePartitionConfigurationBackup
INTEGER,
modulePartitionConfigurationRestore
INTEGER,
moduleSwRevertStatus
INTEGER,
moduleMaxOutputPidsStatus
INTEGER,
moduleUserRebootStatus
INTEGER,
moduleRemovalStatus
INTEGER,
moduleInsertionStatus
INTEGER,
moduleSptsInputConfStatus
INTEGER
}
-- 1.3.6.1.4.1.3715.17.5.2.1.1
moduleId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Module identifier"
::= { moduleStatusEntry 1 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4
modulePidConflictStatus OBJECT-TYPE
SYNTAX INTEGER
{
pidOk(1),
pidConflict(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PID conflict status"
::= { moduleStatusEntry 4 }
-- 1.3.6.1.4.1.3715.17.5.2.1.6
moduleTemperatureHigh OBJECT-TYPE
SYNTAX INTEGER
{
temperatureNominal(1),
temperatureHigh(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High temperature status"
::= { moduleStatusEntry 6 }
-- 1.3.6.1.4.1.3715.17.5.2.1.7
moduleTemperatureLow OBJECT-TYPE
SYNTAX INTEGER
{
temperatureNominal(1),
temperatureLow(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low temperature status"
::= { moduleStatusEntry 7 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4104
modulePidCapaStatus OBJECT-TYPE
SYNTAX INTEGER
{
capacityNominal(1),
capacityExceeded(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module PID capacity status"
::= { moduleStatusEntry 4104 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4105
modulePsisiCaptureCapaStatus OBJECT-TYPE
SYNTAX INTEGER
{
capacityNominal(1),
capacityExceeded(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module PSI/SI table capture capacity status"
::= { moduleStatusEntry 4105 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4106
moduleSidAllocStatus OBJECT-TYPE
SYNTAX INTEGER
{
sidAllocOk(1),
sidAllocCapaExceeded(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module service ID allocation capacity status"
::= { moduleStatusEntry 4106 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4108
moduleCaDetectStatus OBJECT-TYPE
SYNTAX INTEGER
{
moduleOk(1),
moduleMissing(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CA module detection status"
::= { moduleStatusEntry 4108 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4111
moduleDetectStatus OBJECT-TYPE
SYNTAX INTEGER
{
moduleOk(1),
moduleUnknown(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module detection status"
::= { moduleStatusEntry 4111 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4112
moduleVoltageHigh OBJECT-TYPE
SYNTAX INTEGER
{
voltageNominal(1),
voltageHigh(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High voltage status"
::= { moduleStatusEntry 4112 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4113
moduleVoltageLow OBJECT-TYPE
SYNTAX INTEGER
{
voltageNominal(1),
voltageLow(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low voltage status"
::= { moduleStatusEntry 4113 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4114
moduleCurrentHigh OBJECT-TYPE
SYNTAX INTEGER
{
currentNominal(1),
currentHigh(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High current status"
::= { moduleStatusEntry 4114 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4115
moduleCurrentLow OBJECT-TYPE
SYNTAX INTEGER
{
currentNominal(1),
currentLow(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low current status"
::= { moduleStatusEntry 4115 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4127
moduleDaemonInitStatus OBJECT-TYPE
SYNTAX INTEGER
{
daemonNominal(1),
daemonInitFailed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module daemon initialization status"
::= { moduleStatusEntry 4127 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4129
moduleDriverStatus OBJECT-TYPE
SYNTAX INTEGER
{
driverNominal(1),
driverFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module device driver status"
::= { moduleStatusEntry 4129 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4130
moduleHwStatus OBJECT-TYPE
SYNTAX INTEGER
{
hwNominal(1),
hwFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module hardware status"
::= { moduleStatusEntry 4130 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4131
moduleFanStatus OBJECT-TYPE
SYNTAX INTEGER
{
fanNominal(1),
fanFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fan status"
::= { moduleStatusEntry 4131 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4132
modulePowerSourceStatus OBJECT-TYPE
SYNTAX INTEGER
{
runningOnMainPower(1),
runningOnBackupPower(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power source status"
::= { moduleStatusEntry 4132 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4133
modulePsuOverloadStatus OBJECT-TYPE
SYNTAX INTEGER
{
psuNominal(1),
psuOverloaded(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Power supply overload status"
::= { moduleStatusEntry 4133 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4134
moduleBootupProgressStatus OBJECT-TYPE
SYNTAX INTEGER
{
moduleNominal(1),
moduleBootingUp(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module bootup progress"
::= { moduleStatusEntry 4134 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4135
moduleBootupRetryStatus OBJECT-TYPE
SYNTAX INTEGER
{
moduleNominal(1),
moduleBootingRetrying(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module bootup retry status"
::= { moduleStatusEntry 4135 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4136
moduleBootupStatus OBJECT-TYPE
SYNTAX INTEGER
{
moduleNominal(1),
moduleBootFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module bootup status"
::= { moduleStatusEntry 4136 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4137
moduleShutdownProgressStatus OBJECT-TYPE
SYNTAX INTEGER
{
moduleNominal(1),
moduleShuttingDown(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module shutdown progress"
::= { moduleStatusEntry 4137 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4138
moduleConnStatus OBJECT-TYPE
SYNTAX INTEGER
{
connectionNominal(1),
connectionLost(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module connection status"
::= { moduleStatusEntry 4138 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4139
moduleCompatStatus OBJECT-TYPE
SYNTAX INTEGER
{
moduleNominal(1),
moduleIncompatible(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module compatibility status"
::= { moduleStatusEntry 4139 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4147
moduleUpcPowerLow OBJECT-TYPE
SYNTAX INTEGER
{
ucpPowerNominal(1),
ucpPowerLow(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module UPC input power low status"
::= { moduleStatusEntry 4147 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4148
moduleUpcPowerHigh OBJECT-TYPE
SYNTAX INTEGER
{
ucpPowerNominal(1),
ucpPowerHigh(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module UPC input power high status"
::= { moduleStatusEntry 4148 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4149
moduleCalibrDataStatus OBJECT-TYPE
SYNTAX INTEGER
{
calibrationDataNominal(1),
calibrationDataMissing(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module calibration data status"
::= { moduleStatusEntry 4149 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4150
moduleCalibrDataCheckStatus OBJECT-TYPE
SYNTAX INTEGER
{
checkOk(1),
checkSkipped(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module calibration data check status"
::= { moduleStatusEntry 4150 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4151
moduleDescrStatus OBJECT-TYPE
SYNTAX INTEGER
{
descramblingOk(1),
descramblingFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module descrambling status"
::= { moduleStatusEntry 4151 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4153
moduleBackupStatus OBJECT-TYPE
SYNTAX INTEGER
{
moduleNominal(1),
moduleSwitchedToBackup(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module backup status"
::= { moduleStatusEntry 4153 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4154
moduleNitOutputsStatus OBJECT-TYPE
SYNTAX INTEGER
{
nitOutputsNominal(1),
noSupportedNitOutputs(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Supported Nit output module status"
::= { moduleStatusEntry 4154 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4155
moduleNitSelectionStatus OBJECT-TYPE
SYNTAX INTEGER
{
nitSelectionNominal(1),
noSelectedNitOutputs(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Nit output selection status"
::= { moduleStatusEntry 4155 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4156
moduleNitConfChangeStatus OBJECT-TYPE
SYNTAX INTEGER
{
nitConfNominal(1),
nitConfChanged(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Nit configuration change status"
::= { moduleStatusEntry 4156 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4157
moduleNitDataQueryStatus OBJECT-TYPE
SYNTAX INTEGER
{
nitDataQueryNominal(1),
nitDataQueryFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Nit data query status"
::= { moduleStatusEntry 4157 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4158
moduleNitWizardStatus OBJECT-TYPE
SYNTAX INTEGER
{
nitWizardNominal(1),
nitWizardFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Nit wizard status"
::= { moduleStatusEntry 4158 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4159
moduleQamFreqStatus OBJECT-TYPE
SYNTAX INTEGER
{
qamFreqUnique(1),
qamFreqDuplicate(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"QAM output unique frequency status"
::= { moduleStatusEntry 4159 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4173
moduleOutputSidStatus OBJECT-TYPE
SYNTAX INTEGER
{
sidOk(1),
sidConflict(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module output SID status"
::= { moduleStatusEntry 4173 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4175
moduleConfStatus OBJECT-TYPE
SYNTAX INTEGER
{
configurationOk(1),
configurationUnsupported(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module configuration status"
::= { moduleStatusEntry 4175 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4176
moduleFreqStatus OBJECT-TYPE
SYNTAX INTEGER
{
freqOk(1),
freqOutOfRange(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module frequency configuration range status"
::= { moduleStatusEntry 4176 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4177
moduleOutputPowerStatus OBJECT-TYPE
SYNTAX INTEGER
{
powerOk(1),
powerOutOfRange(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module output power status"
::= { moduleStatusEntry 4177 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4178
moduleSymrateStatus OBJECT-TYPE
SYNTAX INTEGER
{
symbolRateOk(1),
symbolRateOutOfRange(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module symbol rate configuration status"
::= { moduleStatusEntry 4178 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4179
moduleChanDistStatus OBJECT-TYPE
SYNTAX INTEGER
{
chanDistOk(1),
chanDistTooNarrow(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module channel distance configuration status"
::= { moduleStatusEntry 4179 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4180
moduleLnbVoltStatus OBJECT-TYPE
SYNTAX INTEGER
{
lnbVoltageOk(1),
lnbVoltageInvalid(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module LNB voltage configuration status"
::= { moduleStatusEntry 4180 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4181
moduleFecRateStatus OBJECT-TYPE
SYNTAX INTEGER
{
fecRateOk(1),
fecRateInvalid(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module FEC rate configuration vs modulation status"
::= { moduleStatusEntry 4181 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4182
moduleLnbCurrStatus OBJECT-TYPE
SYNTAX INTEGER
{
lnbCurrentOk(1),
lnbCurrentInvalid(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module LNB current status"
::= { moduleStatusEntry 4182 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4183
moduleFreqOffsetStatus OBJECT-TYPE
SYNTAX INTEGER
{
freqOffsetOk(1),
freqOffsetInvalid(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module frequency offset configuration status"
::= { moduleStatusEntry 4183 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4185
moduleDescrRestartStatus OBJECT-TYPE
SYNTAX INTEGER
{
descramblingNominal(1),
descramblingRestarting(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module descrambling restart status"
::= { moduleStatusEntry 4185 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4186
moduleCamRestartStatus OBJECT-TYPE
SYNTAX INTEGER
{
camNominal(1),
camRestarting(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module CAM restart status"
::= { moduleStatusEntry 4186 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4187
moduleEcmgStatus OBJECT-TYPE
SYNTAX INTEGER
{
ecmgNominal(1),
ecmgFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ecmg status"
::= { moduleStatusEntry 4187 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4188
moduleEcmStreamStatus OBJECT-TYPE
SYNTAX INTEGER
{
ecmStreamNominal(1),
ecmStreamFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ecm stream status"
::= { moduleStatusEntry 4188 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4189
moduleEmmStatus OBJECT-TYPE
SYNTAX INTEGER
{
emmNominal(1),
emmFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Emm status"
::= { moduleStatusEntry 4189 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4190
moduleEmmStreamStatus OBJECT-TYPE
SYNTAX INTEGER
{
emmStreamNominal(1),
emmStreamFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Emm stream status"
::= { moduleStatusEntry 4190 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4191
moduleEcmgConnStatus OBJECT-TYPE
SYNTAX INTEGER
{
ecmgConnNominal(1),
ecmgNotConnected(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ecmg connection status"
::= { moduleStatusEntry 4191 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4192
moduleEmmConnStatus OBJECT-TYPE
SYNTAX INTEGER
{
emmConnNominal(1),
emmNotConnected(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Emm connection status"
::= { moduleStatusEntry 4192 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4194
moduleEcmgSpareStatus OBJECT-TYPE
SYNTAX INTEGER
{
ecmgNominal(1),
ecmgSwitchedToSpare(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ecmg spare connection status"
::= { moduleStatusEntry 4194 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4195
moduleBootloaderAvailStatus OBJECT-TYPE
SYNTAX INTEGER
{
bootloaderOk(1),
bootloaderObsolete(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module bootloader availability status"
::= { moduleStatusEntry 4195 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4196
moduleBl1UpdateProgStatus OBJECT-TYPE
SYNTAX INTEGER
{
bootloaderNominal(1),
bootloaderUpdating(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module bootloader update progress"
::= { moduleStatusEntry 4196 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4197
moduleBl2UpdateProgStatus OBJECT-TYPE
SYNTAX INTEGER
{
bootloaderNominal(1),
bootloaderUpdating(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module bootloader update progress"
::= { moduleStatusEntry 4197 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4198
moduleBl1UpdateStatus OBJECT-TYPE
SYNTAX INTEGER
{
bootloaderNominal(1),
bootloaderUpdateFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module bootloader update status"
::= { moduleStatusEntry 4198 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4199
moduleBl2UpdateStatus OBJECT-TYPE
SYNTAX INTEGER
{
bootloaderNominal(1),
bootloaderUpdateFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module bootloader update status"
::= { moduleStatusEntry 4199 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4203
moduleActiveBackupStatus OBJECT-TYPE
SYNTAX INTEGER
{
backupPassive(1),
backupActive(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backup module status"
::= { moduleStatusEntry 4203 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4205
moduleConfProgressStatus OBJECT-TYPE
SYNTAX INTEGER
{
moduleNominal(1),
moduleConfiguring(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module configuration progress"
::= { moduleStatusEntry 4205 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4206
modulePresenceStatus OBJECT-TYPE
SYNTAX INTEGER
{
moduleNominal(1),
noModule(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module presence progress"
::= { moduleStatusEntry 4206 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4208
moduleProcessRestartStatus OBJECT-TYPE
SYNTAX INTEGER
{
processesNominal(1),
processRestarted(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Process restart status"
::= { moduleStatusEntry 4208 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4209
moduleBackupLicenseStatus OBJECT-TYPE
SYNTAX INTEGER
{
licenseOk(1),
notLicensed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backup license status"
::= { moduleStatusEntry 4209 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4210
modulePsisiEditorLicenseStatus OBJECT-TYPE
SYNTAX INTEGER
{
licenseOk(1),
notLicensed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PSI/SI editor license status"
::= { moduleStatusEntry 4210 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4211
moduleMuxLicenseStatus OBJECT-TYPE
SYNTAX INTEGER
{
licenseOk(1),
notLicensed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Multiplexing license status"
::= { moduleStatusEntry 4211 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4212
moduleDemuxLicenseStatus OBJECT-TYPE
SYNTAX INTEGER
{
licenseOk(1),
notLicensed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Demultiplexing license status"
::= { moduleStatusEntry 4212 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4213
moduleDvbLicenseStatus OBJECT-TYPE
SYNTAX INTEGER
{
licenseOk(1),
notLicensed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DVB processing license status"
::= { moduleStatusEntry 4213 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4214
moduleMsdLicenseStatus OBJECT-TYPE
SYNTAX INTEGER
{
licenseOk(1),
notLicensed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MSD license status"
::= { moduleStatusEntry 4214 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4215
moduleDvbs2LicenseStatus OBJECT-TYPE
SYNTAX INTEGER
{
licenseOk(1),
notLicensed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DVB-S2 processing license status"
::= { moduleStatusEntry 4215 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4216
moduleDvbt2LicenseStatus OBJECT-TYPE
SYNTAX INTEGER
{
licenseOk(1),
notLicensed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DVB-T2 processing license status"
::= { moduleStatusEntry 4216 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4217
moduleScsLicenseStatus OBJECT-TYPE
SYNTAX INTEGER
{
licenseValid(1),
notLicensed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Scs license status"
::= { moduleStatusEntry 4217 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4218
moduleCliLoginStatus OBJECT-TYPE
SYNTAX INTEGER
{
cliNotLoggedIn(1),
cliLoggedIn(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CLI login status"
::= { moduleStatusEntry 4218 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4222
moduleRedunActivationStatus OBJECT-TYPE
SYNTAX INTEGER
{
redundancyPassive(1),
redundancyActivated(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Redundancy activation status"
::= { moduleStatusEntry 4222 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4223
moduleExtioPinSignalingStatus OBJECT-TYPE
SYNTAX INTEGER
{
extioPinNominal(1),
extioPinSignaled(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"EXT-IO pin status"
::= { moduleStatusEntry 4223 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4224
moduleBackupPsuStatus OBJECT-TYPE
SYNTAX INTEGER
{
backupPsuNominal(1),
backupPsuFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backup power supply status"
::= { moduleStatusEntry 4224 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4225
moduleIntrusionStatus OBJECT-TYPE
SYNTAX INTEGER
{
intrusionNominal(1),
intrusionDetected(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Intrusion detection status"
::= { moduleStatusEntry 4225 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4227
moduleRedunStatus OBJECT-TYPE
SYNTAX INTEGER
{
redundancyOk(1),
redundancyFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Redundancy status"
::= { moduleStatusEntry 4227 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4230
moduleBackupHwStatus OBJECT-TYPE
SYNTAX INTEGER
{
backupHwOk(1),
backupHwNotSupported(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hardware backup support status"
::= { moduleStatusEntry 4230 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4231
moduleSwUpdateProgress OBJECT-TYPE
SYNTAX INTEGER
{
swUpdateInactive(1),
swUpdateInProgress(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Software update progress"
::= { moduleStatusEntry 4231 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4233
moduleSwUpdateStatus OBJECT-TYPE
SYNTAX INTEGER
{
swNominal(1),
swUpdateFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Software update status"
::= { moduleStatusEntry 4233 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4235
moduleEitLicenseStatus OBJECT-TYPE
SYNTAX INTEGER
{
licenseValid(1),
notLicensed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"EIT license status"
::= { moduleStatusEntry 4235 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4237
moduleDescramblingStatus OBJECT-TYPE
SYNTAX INTEGER
{
descramblingNominal(1),
descramblingFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Descrambling status"
::= { moduleStatusEntry 4237 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4243
moduleDvbTimeStatus OBJECT-TYPE
SYNTAX INTEGER
{
dvbTimeNominal(1),
dvbTimeMissing(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DVB time detection status"
::= { moduleStatusEntry 4243 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4245
moduleTunerDcFeedStatus OBJECT-TYPE
SYNTAX INTEGER
{
currentNominal(1),
currentOutOfRange(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tuner DC feed current status"
::= { moduleStatusEntry 4245 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4247
moduleTunerPlpSelectionReqStatus OBJECT-TYPE
SYNTAX INTEGER
{
plpSelectionOk(1),
plpSelectionRequired(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tuner data PLP ID requirement status"
::= { moduleStatusEntry 4247 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4248
moduleTunerPlpStatus OBJECT-TYPE
SYNTAX INTEGER
{
plpSelectionValid(1),
plpSelectionNotValid(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tuner data PLP ID validity status"
::= { moduleStatusEntry 4248 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4249
moduleTunerHierarchyStatus OBJECT-TYPE
SYNTAX INTEGER
{
hierarchyOk(1),
hierarchyInvalid(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of transmission hierarchy"
::= { moduleStatusEntry 4249 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4250
moduleEcmStatus OBJECT-TYPE
SYNTAX INTEGER
{
ecmNominal(1),
ecmMissing(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ECM stream connection status"
::= { moduleStatusEntry 4250 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4251
moduleScramConflictStatus OBJECT-TYPE
SYNTAX INTEGER
{
scramblingNominal(1),
scramblingConflict(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module scrambling shared component conflict status"
::= { moduleStatusEntry 4251 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4252
moduleScramSharedStatus OBJECT-TYPE
SYNTAX INTEGER
{
scramblingNominal(1),
scramblingSharedComponent(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Module scrambling shared component status"
::= { moduleStatusEntry 4252 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4253
moduleBackupVoltageHigh OBJECT-TYPE
SYNTAX INTEGER
{
voltageNominal(1),
voltageHigh(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backup high voltage status"
::= { moduleStatusEntry 4253 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4254
moduleBackupVoltageLow OBJECT-TYPE
SYNTAX INTEGER
{
voltageNominal(1),
voltageLow(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backup low voltage status"
::= { moduleStatusEntry 4254 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4255
moduleSdtTableStatus OBJECT-TYPE
SYNTAX INTEGER
{
sdtTableOk(1),
invalidSdtTableTemplate(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sdt table template status"
::= { moduleStatusEntry 4255 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4256
moduleDescramblingRestart OBJECT-TYPE
SYNTAX INTEGER
{
descramblingNominal(1),
descramblingRestarting(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Descrambling restart status"
::= { moduleStatusEntry 4256 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4257
moduleCaModuleRestart OBJECT-TYPE
SYNTAX INTEGER
{
caModuleNominal(1),
caModuleRestarting(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CA module restart status"
::= { moduleStatusEntry 4257 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4258
moduleCaMenuStatus OBJECT-TYPE
SYNTAX INTEGER
{
caMenuNominal(1),
caMenuOpen(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CA menu access status"
::= { moduleStatusEntry 4258 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4259
moduleInvalidCamRouting OBJECT-TYPE
SYNTAX INTEGER
{
camRoutingNominal(1),
camRoutingInvalid(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CAM routing status"
::= { moduleStatusEntry 4259 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4260
moduleNitSidConflict OBJECT-TYPE
SYNTAX INTEGER
{
nitSidNominal(1),
nitSidConflict(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Nit / Sid conflict status"
::= { moduleStatusEntry 4260 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4262
moduleLicenseMissingFEC OBJECT-TYPE
SYNTAX INTEGER
{
licenseOk(1),
licenseMissing(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"FEC license status"
::= { moduleStatusEntry 4262 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4263
moduleFecCorrectionStatus OBJECT-TYPE
SYNTAX INTEGER
{
correctionNominal(1),
correctionOverload(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fec packet correction status. Correction overload (2) is result of too many simultaneous missing packets."
::= { moduleStatusEntry 4263 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4264
moduleFecPacketDropStatus OBJECT-TYPE
SYNTAX INTEGER
{
packetsNominal(1),
packetsDropped(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"FEC packet discarding status. Packet discarding (2) is resulted by too high bitrate."
::= { moduleStatusEntry 4264 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4265
moduleFecMediaPktsStatus OBJECT-TYPE
SYNTAX INTEGER
{
packetsNominal(1),
packetsDiscarded(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fec media packet discarding status. Packet discarding (2) is resulted by too high bitrate."
::= { moduleStatusEntry 4265 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4269
moduleSfpLinkStatus OBJECT-TYPE
SYNTAX INTEGER
{
sfpLinkNominal(1),
sfpLinkDown(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SFP link status"
::= { moduleStatusEntry 4269 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4272
moduleBackupSyncModeOff OBJECT-TYPE
SYNTAX INTEGER
{
modeNominal(1),
modeOff(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backup sync mode off status flag"
::= { moduleStatusEntry 4272 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4273
moduleBackupSyncModeManual OBJECT-TYPE
SYNTAX INTEGER
{
modeNominal(1),
modeManual(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backup sync mode manual status flag"
::= { moduleStatusEntry 4273 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4274
moduleBackupSyncModeAuto OBJECT-TYPE
SYNTAX INTEGER
{
modeNominal(1),
modeAuto(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backup sync mode automatic status flag"
::= { moduleStatusEntry 4274 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4275
moduleBackupSyncConfStatus OBJECT-TYPE
SYNTAX INTEGER
{
configurationNominal(1),
configurationChanged(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backup sync configuration change status"
::= { moduleStatusEntry 4275 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4276
moduleBackupSyncStatus OBJECT-TYPE
SYNTAX INTEGER
{
syncNominal(1),
synchronizing(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backup configuration synchronization status"
::= { moduleStatusEntry 4276 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4278
moduleBackupSyncSwCompatibility OBJECT-TYPE
SYNTAX INTEGER
{
swCompatible(1),
swIncompatible(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Software version compatibility for backup sync"
::= { moduleStatusEntry 4278 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4279
moduleBackupSyncHwCompatibility OBJECT-TYPE
SYNTAX INTEGER
{
hwCompatible(1),
hwIncompatible(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hardware version compatibility for backup sync"
::= { moduleStatusEntry 4279 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4280
moduleBackupSyncConfFaultStatus OBJECT-TYPE
SYNTAX INTEGER
{
configurationNominal(1),
configurationFault(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backup sync configuration fault status"
::= { moduleStatusEntry 4280 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4281
moduleBackupSyncConnectionStatus OBJECT-TYPE
SYNTAX INTEGER
{
connectionNominal(1),
connectionLost(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backup sync connection status"
::= { moduleStatusEntry 4281 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4283
moduleBackupSyncFromBackupStatus OBJECT-TYPE
SYNTAX INTEGER
{
syncNominal(1),
syncNotPossible(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status flag for backup autosync from backup to main"
::= { moduleStatusEntry 4283 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4284
moduleBackupSyncRebootStatus OBJECT-TYPE
SYNTAX INTEGER
{
pairDevNominal(1),
pairDevRebooting(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status flag for rebooting pair device to new configuration"
::= { moduleStatusEntry 4284 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4285
moduleBackupSyncLicenseCompatStatus OBJECT-TYPE
SYNTAX INTEGER
{
licensesCompatible(1),
licensesIncompatible(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"License compatibility status flag for backup sync"
::= { moduleStatusEntry 4285 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4286
moduleBackupSyncLicenseCompareStatus OBJECT-TYPE
SYNTAX INTEGER
{
licenseNominal(1),
licenseComparing(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Backup sync license comparing status"
::= { moduleStatusEntry 4286 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4288
moduleDeviceFirstBootStatus OBJECT-TYPE
SYNTAX INTEGER
{
firstBootNominal(1),
firstBootInProgress(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status flag for device first boot operations"
::= { moduleStatusEntry 4288 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4289
modulePartitionConfigurationBackup OBJECT-TYPE
SYNTAX INTEGER
{
configurationNominal(1),
configurationBackupInProgress(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status flag for partition configuration backup operation"
::= { moduleStatusEntry 4289 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4290
modulePartitionConfigurationRestore OBJECT-TYPE
SYNTAX INTEGER
{
configurationNominal(1),
configurationRestoreInProgress(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status flag for partition configuration restore operation"
::= { moduleStatusEntry 4290 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4291
moduleSwRevertStatus OBJECT-TYPE
SYNTAX INTEGER
{
swNominal(1),
swRevertInProgress(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Software revertion status"
::= { moduleStatusEntry 4291 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4292
moduleMaxOutputPidsStatus OBJECT-TYPE
SYNTAX INTEGER
{
pidsNominal(1),
maxPidsUsed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status flag for maximum number of Pid allocations"
::= { moduleStatusEntry 4292 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4293
moduleUserRebootStatus OBJECT-TYPE
SYNTAX INTEGER
{
moduleNominal(1),
moduleRebootedByUser(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status flag for user initiated reboot"
::= { moduleStatusEntry 4293 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4294
moduleRemovalStatus OBJECT-TYPE
SYNTAX INTEGER
{
moduleNominal(1),
moduleRemoved(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status flag for module removal"
::= { moduleStatusEntry 4294 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4295
moduleInsertionStatus OBJECT-TYPE
SYNTAX INTEGER
{
moduleNominal(1),
moduleInserted(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status flag for module insertion"
::= { moduleStatusEntry 4295 }
-- 1.3.6.1.4.1.3715.17.5.2.1.4296
moduleSptsInputConfStatus OBJECT-TYPE
SYNTAX INTEGER
{
sptsInputNominal(1),
inputNotSpts(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status flag for input spts misconfiguration"
::= { moduleStatusEntry 4296 }
-- 1.3.6.1.4.1.3715.17.5.3
ifStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " "
::= { statusFlags 3 }
-- 1.3.6.1.4.1.3715.17.5.3.1
ifStatusEntry OBJECT-TYPE
SYNTAX IfStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " "
INDEX { moduleId, ifDirection, ifId }
::= { ifStatusTable 1 }
IfStatusEntry ::=
SEQUENCE {
ifId
INTEGER,
ifDirection
INTEGER,
ifSignalStatus
INTEGER,
ifAsiLinkStatus
INTEGER,
ifLinkStatus
INTEGER
}
-- 1.3.6.1.4.1.3715.17.5.3.1.1
ifId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interface identifier"
::= { ifStatusEntry 1 }
-- 1.3.6.1.4.1.3715.17.5.3.1.2
ifDirection OBJECT-TYPE
SYNTAX INTEGER
{
input(1),
output(2),
both(3)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interface data direction"
::= { ifStatusEntry 2 }
-- 1.3.6.1.4.1.3715.17.5.3.1.4097
ifSignalStatus OBJECT-TYPE
SYNTAX INTEGER
{
signalOk(1),
signalMissing(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interface signal status"
::= { ifStatusEntry 4097 }
-- 1.3.6.1.4.1.3715.17.5.3.1.4102
ifAsiLinkStatus OBJECT-TYPE
SYNTAX INTEGER
{
linkOk(1),
linkDown(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ASI link status"
::= { ifStatusEntry 4102 }
-- 1.3.6.1.4.1.3715.17.5.3.1.4226
ifLinkStatus OBJECT-TYPE
SYNTAX INTEGER
{
linkOk(1),
linkDown(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interface link status"
::= { ifStatusEntry 4226 }
-- 1.3.6.1.4.1.3715.17.5.4
tsStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF TsStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " "
::= { statusFlags 4 }
-- 1.3.6.1.4.1.3715.17.5.4.1
tsStatusEntry OBJECT-TYPE
SYNTAX TsStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " "
INDEX { moduleId, ifDirection, ifId }
::= { tsStatusTable 1 }
TsStatusEntry ::=
SEQUENCE {
tsPidRemappingStatus
INTEGER,
tsManualTableInsertStatus
INTEGER,
tsPassthruDupStatus
INTEGER,
tsSyncStatus
INTEGER,
tsRxStatus
INTEGER,
tsInputBufferStatus
INTEGER,
tsNetworkStatus
INTEGER,
tsPsisiCapaStatus
INTEGER,
tsMultiplexDiscardStatus
INTEGER,
tsMultiplexDelayStatus
INTEGER,
tsCbrOversubscriptionStatus
INTEGER,
tsCbrDiscardStatus
INTEGER,
tsIpInputCapaStatus
INTEGER,
tsEitReinsertCapaStatus
INTEGER,
tsSectionCapaStatus
INTEGER,
tsRtpInputStatus
INTEGER,
tsRtpSeqStatus
INTEGER,
tsTdtTotGenStatus
INTEGER,
tsSttGenStatus
INTEGER,
tsFecPacketCorrectionStatus
INTEGER,
tsFecInputAnomalyStatus
INTEGER,
tsFecCorrectionCapacityStatus
INTEGER,
tsIpMirrorOutputPacketLossStatus
INTEGER
}
-- 1.3.6.1.4.1.3715.17.5.4.1.5
tsPidRemappingStatus OBJECT-TYPE
SYNTAX INTEGER
{
pidNominal(1),
pidRemapped(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS PID remapping status"
::= { tsStatusEntry 5 }
-- 1.3.6.1.4.1.3715.17.5.4.1.8
tsManualTableInsertStatus OBJECT-TYPE
SYNTAX INTEGER
{
insertOk(1),
insertFailure(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS manual table insertion status"
::= { tsStatusEntry 8 }
-- 1.3.6.1.4.1.3715.17.5.4.1.11
tsPassthruDupStatus OBJECT-TYPE
SYNTAX INTEGER
{
servicesNominal(1),
servicesBlocked(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS output service passthrough duplication status"
::= { tsStatusEntry 11 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4098
tsSyncStatus OBJECT-TYPE
SYNTAX INTEGER
{
syncOk(1),
noSync(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS sync status"
::= { tsStatusEntry 4098 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4099
tsRxStatus OBJECT-TYPE
SYNTAX INTEGER
{
rxNominal(1),
rxErrors(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS Rx error status"
::= { tsStatusEntry 4099 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4100
tsInputBufferStatus OBJECT-TYPE
SYNTAX INTEGER
{
bufferNominal(1),
bufferOverflow(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS input buffer status"
::= { tsStatusEntry 4100 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4103
tsNetworkStatus OBJECT-TYPE
SYNTAX INTEGER
{
netOk(1),
netForbidden(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS network ID status"
::= { tsStatusEntry 4103 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4109
tsPsisiCapaStatus OBJECT-TYPE
SYNTAX INTEGER
{
capacityNominal(1),
capacityExceeded(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS PSI/SI insertion capacity status"
::= { tsStatusEntry 4109 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4110
tsMultiplexDiscardStatus OBJECT-TYPE
SYNTAX INTEGER
{
muxNominal(1),
muxPacketsDiscarded(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS multiplex packet discard status"
::= { tsStatusEntry 4110 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4228
tsMultiplexDelayStatus OBJECT-TYPE
SYNTAX INTEGER
{
muxNominal(1),
muxPacketsDelayed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS multiplex packet delay status"
::= { tsStatusEntry 4228 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4229
tsCbrOversubscriptionStatus OBJECT-TYPE
SYNTAX INTEGER
{
cbrNominal(1),
cbrOversubscription(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS CBR oversubscription status"
::= { tsStatusEntry 4229 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4236
tsCbrDiscardStatus OBJECT-TYPE
SYNTAX INTEGER
{
cbrNominal(1),
cbrPacketsDiscarded(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS CBR packet discard due to oversubscription status"
::= { tsStatusEntry 4236 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4238
tsIpInputCapaStatus OBJECT-TYPE
SYNTAX INTEGER
{
capacityNominal(1),
capacityExceeded(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS IP input capacity status"
::= { tsStatusEntry 4238 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4239
tsEitReinsertCapaStatus OBJECT-TYPE
SYNTAX INTEGER
{
capacityNominal(1),
capacityExceeded(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS EIT reinsert capacity status"
::= { tsStatusEntry 4239 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4240
tsSectionCapaStatus OBJECT-TYPE
SYNTAX INTEGER
{
capacityNominal(1),
capacityExceeded(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS section processing capacity status"
::= { tsStatusEntry 4240 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4241
tsRtpInputStatus OBJECT-TYPE
SYNTAX INTEGER
{
inputOk(1),
inputPacketsDropped(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS RTP input packet droip status"
::= { tsStatusEntry 4241 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4242
tsRtpSeqStatus OBJECT-TYPE
SYNTAX INTEGER
{
seqOk(1),
seqAnomalies(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS RTP input packet sequence anomaly status"
::= { tsStatusEntry 4242 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4246
tsTdtTotGenStatus OBJECT-TYPE
SYNTAX INTEGER
{
tdtTotOk(1),
tdtTotNotGenerated(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS output TDT/TOT table generation status"
::= { tsStatusEntry 4246 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4261
tsSttGenStatus OBJECT-TYPE
SYNTAX INTEGER
{
sttOk(1),
sttNotGenerated(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TS output STT table generation status"
::= { tsStatusEntry 4261 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4266
tsFecPacketCorrectionStatus OBJECT-TYPE
SYNTAX INTEGER
{
packetsNominal(1),
fecCorrectedPackets(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status flag for FEC correcting packets"
::= { tsStatusEntry 4266 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4267
tsFecInputAnomalyStatus OBJECT-TYPE
SYNTAX INTEGER
{
fecInputNominal(1),
fecInputAnomalies(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status flag for FEC input anomaly detection"
::= { tsStatusEntry 4267 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4268
tsFecCorrectionCapacityStatus OBJECT-TYPE
SYNTAX INTEGER
{
correctionCapacityNominal(1),
correctionCapacityExceeded(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fec input packets correction capacity status"
::= { tsStatusEntry 4268 }
-- 1.3.6.1.4.1.3715.17.5.4.1.4297
tsIpMirrorOutputPacketLossStatus OBJECT-TYPE
SYNTAX INTEGER
{
ipOutputNominal(1),
ipOutputPacketsDiscarded(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status flag for IP mirror output packet discarding"
::= { tsStatusEntry 4297 }
-- 1.3.6.1.4.1.3715.17.5.5
serviceStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ServiceStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " "
::= { statusFlags 5 }
-- 1.3.6.1.4.1.3715.17.5.5.1
serviceStatusEntry OBJECT-TYPE
SYNTAX ServiceStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " "
INDEX { moduleId, ifDirection, ifId, serviceId }
::= { serviceStatusTable 1 }
ServiceStatusEntry ::=
SEQUENCE {
serviceId
INTEGER,
serviceStatus
INTEGER
}
-- 1.3.6.1.4.1.3715.17.5.5.1.1
serviceId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Service identifier"
::= { serviceStatusEntry 1 }
-- 1.3.6.1.4.1.3715.17.5.5.1.3
serviceStatus OBJECT-TYPE
SYNTAX INTEGER
{
servicePresent(1),
serviceMissing(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Service status"
::= { serviceStatusEntry 3 }
-- 1.3.6.1.4.1.3715.17.5.6
pidStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PidStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " "
::= { statusFlags 6 }
-- 1.3.6.1.4.1.3715.17.5.6.1
pidStatusEntry OBJECT-TYPE
SYNTAX PidStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " "
INDEX { moduleId, ifDirection, ifId, pId }
::= { pidStatusTable 1 }
PidStatusEntry ::=
SEQUENCE {
pId
INTEGER,
pidStatus
INTEGER
}
-- 1.3.6.1.4.1.3715.17.5.6.1.1
pId OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Program Identifier"
::= { pidStatusEntry 1 }
-- 1.3.6.1.4.1.3715.17.5.6.1.2
pidStatus OBJECT-TYPE
SYNTAX INTEGER
{
pidPresent(1),
pidMissing(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PID status"
::= { pidStatusEntry 2 }
END
--
-- TELESTE-LUMINATO-MIB.mib
--