667 lines
24 KiB
Plaintext
667 lines
24 KiB
Plaintext
-- *****************************************************************
|
|
-- UBQS-ENVMON-MIB: Ubiquoss Environmental Monitor MIB file
|
|
--
|
|
-- June 2009 by Hyung Eun Park
|
|
--
|
|
-- Copyright (c) 2009 by Ubiquoss, Corp.
|
|
-- All rights reserved.
|
|
-- *****************************************************************
|
|
--
|
|
|
|
UBQS-ENVMON-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
NOTIFICATION-TYPE,
|
|
Gauge32,
|
|
Integer32
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION,
|
|
DisplayString,
|
|
TruthValue
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP,
|
|
NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
ubiMgmtv2
|
|
FROM UBQS-SMI;
|
|
|
|
|
|
ubiEnvMonMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200906250000Z"
|
|
ORGANIZATION "Ubiquoss Corp."
|
|
CONTACT-INFO
|
|
" Ubiquoss
|
|
Customer Service
|
|
|
|
Postal: 24F Milennium B/D,
|
|
467-12, Dogok-Dong,
|
|
GangNam-Gu, Seoul 135-270
|
|
Korea
|
|
|
|
Tel: 82-2-2190-3100"
|
|
DESCRIPTION
|
|
"The UBQS-ENVMON-MIB is used for getting
|
|
the environment information of the system."
|
|
::= { ubiMgmtv2 2 }
|
|
|
|
|
|
-- *****************************************************************
|
|
-- Type Convention
|
|
-- *****************************************************************
|
|
UbiEnvMonState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents the state of a device being monitored.
|
|
Valid values are:
|
|
|
|
normal(1): the environment is good, such as low
|
|
temperature.
|
|
|
|
warning(2): the environment is bad, such as temperature
|
|
above normal operation range but not too
|
|
high.
|
|
|
|
critical(3): the environment is very bad, such as
|
|
temperature much higher than normal
|
|
operation limit.
|
|
|
|
shutdown(4): the environment is the worst, the system
|
|
should be shutdown immediately.
|
|
|
|
notPresent(5): the environmental monitor is not present,
|
|
such as temperature sensors do not exist.
|
|
|
|
notFunctioning(6): the environmental monitor does not
|
|
function properly.
|
|
"
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
warning(2),
|
|
critical(3),
|
|
shutdown(4),
|
|
notPresent(5),
|
|
notFunctioning(6)
|
|
}
|
|
|
|
-- *****************************************************************
|
|
-- ubiEnvMonMIB
|
|
-- *****************************************************************
|
|
|
|
ubiEnvMonObjects OBJECT IDENTIFIER ::= { ubiEnvMonMIB 1 }
|
|
ubiEnvMonMIBNotificationEnables OBJECT IDENTIFIER ::= { ubiEnvMonMIB 2 }
|
|
ubiEnvMonMIBNotificationPrefix OBJECT IDENTIFIER ::= { ubiEnvMonMIB 3 }
|
|
ubiEnvMonMIBConformance OBJECT IDENTIFIER ::= { ubiEnvMonMIB 4 }
|
|
|
|
|
|
|
|
-- *****************************************************************
|
|
-- ubiEnvMonTemperatureTable
|
|
-- *****************************************************************
|
|
|
|
ubiEnvMonTemperatureTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UbiEnvMonTemperatureEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table of ambient temperature status maintained by the
|
|
environmental monitor."
|
|
::= { ubiEnvMonObjects 1 }
|
|
|
|
ubiEnvMonTemperatureEntry OBJECT-TYPE
|
|
SYNTAX UbiEnvMonTemperatureEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the ambient temperature status table, representing
|
|
the status of the associated testpoint maintained by the
|
|
environmental monitor."
|
|
INDEX { ubiEnvMonTemperatureIndex }
|
|
::= { ubiEnvMonTemperatureTable 1 }
|
|
|
|
UbiEnvMonTemperatureEntry ::=
|
|
SEQUENCE {
|
|
ubiEnvMonTemperatureIndex Integer32,
|
|
ubiEnvMonTemperatureDescr DisplayString,
|
|
ubiEnvMonTemperatureValue Gauge32,
|
|
ubiEnvMonTemperatureHighThreshold Integer32,
|
|
ubiEnvMonTemperatureLowThreshold Integer32,
|
|
-- ubiEnvMonTemperatureLastShutdown Integer32,
|
|
ubiEnvMonTemperatureState UbiEnvMonState
|
|
}
|
|
|
|
|
|
ubiEnvMonTemperatureIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique index for the testpoint being instrumented.
|
|
This index is for SNMP purposes only, and has no
|
|
intrinsic meaning."
|
|
::= { ubiEnvMonTemperatureEntry 1 }
|
|
|
|
ubiEnvMonTemperatureDescr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Textual description of the testpoint
|
|
being instrumented."
|
|
::= { ubiEnvMonTemperatureEntry 2 }
|
|
|
|
ubiEnvMonTemperatureValue OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "degrees Celsius"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current measurement of the testpoint
|
|
being instrumented."
|
|
::= { ubiEnvMonTemperatureEntry 3 }
|
|
|
|
ubiEnvMonTemperatureHighThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Celsius"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A high threshold for the temperature.
|
|
If a particular value isn't set, this object
|
|
displays the default value."
|
|
::= { ubiEnvMonTemperatureEntry 4 }
|
|
|
|
ubiEnvMonTemperatureLowThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Celsius"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A low threshold for the temperature.
|
|
If a particular value isn't set, this object
|
|
displays the default value."
|
|
::= { ubiEnvMonTemperatureEntry 5 }
|
|
|
|
-- ubiEnvMonTemperatureLastShutdown OBJECT-TYPE
|
|
-- SYNTAX Integer32
|
|
-- UNITS "degrees Celsius"
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "The value of the associated instance of the object
|
|
-- ubiEnvMonTemperatureStatusValue at the time an emergency
|
|
-- shutdown of the managed device was last initiated. "
|
|
-- ::= { ubiEnvMonTemperatureEntry 5 }
|
|
|
|
ubiEnvMonTemperatureState OBJECT-TYPE
|
|
SYNTAX UbiEnvMonState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current state of the testpoint being instrumented.
|
|
Represents the temperature state of a device being monitored.
|
|
Valid values are:
|
|
|
|
normal(1): the environment is good, such as low
|
|
temperature.
|
|
|
|
warning(2): the environment is bad, such as temperature
|
|
above normal operation range but not too
|
|
high.
|
|
|
|
critical(3): the environment is very bad, such as
|
|
temperature much higher than normal
|
|
operation limit.
|
|
|
|
notPresent(5): the environmental monitor is not present,
|
|
such as temperature sensors do not exist.
|
|
"
|
|
::= { ubiEnvMonTemperatureEntry 6 }
|
|
|
|
|
|
-- *****************************************************************
|
|
-- ubiEnvMonFanTable
|
|
-- ****************************************************************
|
|
|
|
ubiEnvMonFanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UbiEnvMonFanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table of fan status maintained by the environmental
|
|
monitor."
|
|
::= { ubiEnvMonObjects 2 }
|
|
|
|
ubiEnvMonFanEntry OBJECT-TYPE
|
|
SYNTAX UbiEnvMonFanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the fan status table, representing the status of
|
|
the associated fan maintained by the environmental monitor."
|
|
INDEX { ubiEnvMonFanIndex }
|
|
::= { ubiEnvMonFanTable 1 }
|
|
|
|
UbiEnvMonFanEntry ::=
|
|
SEQUENCE {
|
|
ubiEnvMonFanIndex Integer32,
|
|
ubiEnvMonFanDescr DisplayString,
|
|
ubiEnvMonFanState UbiEnvMonState
|
|
}
|
|
|
|
ubiEnvMonFanIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique index for the fan being instrumented.
|
|
This index is for SNMP purposes only, and has no
|
|
intrinsic meaning."
|
|
::= { ubiEnvMonFanEntry 1 }
|
|
|
|
ubiEnvMonFanDescr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Textual description of the fan being instrumented."
|
|
::= { ubiEnvMonFanEntry 2 }
|
|
|
|
ubiEnvMonFanState OBJECT-TYPE
|
|
SYNTAX UbiEnvMonState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current state of the fan being instrumented.
|
|
Represents the fan state of a device being monitored.
|
|
Valid values are:
|
|
|
|
normal(1): the environment is good, such as low
|
|
temperature.
|
|
|
|
notPresent(5): the environmental monitor is not present,
|
|
such as temperature sensors do not exist.
|
|
|
|
notFunctioning(6): the environmental monitor does not
|
|
function properly.
|
|
"
|
|
|
|
::= { ubiEnvMonFanEntry 3 }
|
|
|
|
|
|
|
|
-- *****************************************************************
|
|
-- ubiEnvMonSupplyTable
|
|
-- ****************************************************************
|
|
|
|
ubiEnvMonSupplyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UbiEnvMonSupplyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table of power supply status maintained by the
|
|
environmental monitor card."
|
|
::= { ubiEnvMonObjects 3 }
|
|
|
|
ubiEnvMonSupplyEntry OBJECT-TYPE
|
|
SYNTAX UbiEnvMonSupplyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the power supply status table, representing the
|
|
status of the associated power supply maintained by the
|
|
environmental monitor card."
|
|
INDEX { ubiEnvMonSupplyIndex }
|
|
::= { ubiEnvMonSupplyTable 1 }
|
|
|
|
UbiEnvMonSupplyEntry ::=
|
|
SEQUENCE {
|
|
ubiEnvMonSupplyIndex Integer32,
|
|
ubiEnvMonSupplyDescr DisplayString,
|
|
ubiEnvMonSupplyState UbiEnvMonState,
|
|
ubiEnvMonSupplySource INTEGER,
|
|
ubiEnvMonExternalAlarmAc INTEGER,
|
|
ubiEnvMonExternalAlarmUnit INTEGER
|
|
}
|
|
|
|
ubiEnvMonSupplyIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique index for the power supply being instrumented.
|
|
This index is for SNMP purposes only, and has no
|
|
intrinsic meaning."
|
|
::= { ubiEnvMonSupplyEntry 1 }
|
|
|
|
ubiEnvMonSupplyDescr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Textual description of the power supply
|
|
being instrumented."
|
|
::= { ubiEnvMonSupplyEntry 2 }
|
|
|
|
ubiEnvMonSupplyState OBJECT-TYPE
|
|
SYNTAX UbiEnvMonState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current state of the power supply
|
|
being instrumented.
|
|
Represents the power state of a device being monitored.
|
|
Valid values are:
|
|
|
|
normal(1): the environment is good, such as low
|
|
temperature.
|
|
|
|
notPresent(5): the environmental monitor is not present,
|
|
such as temperature sensors do not exist.
|
|
|
|
notFunctioning(6): the environmental monitor does not
|
|
function properly.
|
|
"
|
|
::= { ubiEnvMonSupplyEntry 3 }
|
|
|
|
ubiEnvMonSupplySource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
ac(1),
|
|
dc(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power supply source.
|
|
ac - AC power supply
|
|
dc - DC power supply"
|
|
::= { ubiEnvMonSupplyEntry 4 }
|
|
|
|
ubiEnvMonExternalAlarmAc OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
fail(2)
|
|
} MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power supply convertor AC.
|
|
nomal (1)
|
|
fail (2)"
|
|
::= { ubiEnvMonSupplyEntry 5 }
|
|
|
|
ubiEnvMonExternalAlarmUnit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
fail(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power supply convertor unit.
|
|
nomal (1)
|
|
fail (2)"
|
|
::= { ubiEnvMonSupplyEntry 6 }
|
|
|
|
|
|
-- *****************************************************************
|
|
-- ubiEnvMonSupplyChannelTable
|
|
-- ****************************************************************
|
|
|
|
ubiEnvMonSupplyChannelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UbiEnvMonSupplyChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table represents the extension status
|
|
for DC power supply."
|
|
::= { ubiEnvMonObjects 4 }
|
|
|
|
ubiEnvMonSupplyChannelEntry OBJECT-TYPE
|
|
SYNTAX UbiEnvMonSupplyChannelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in this table, representing the extended status of
|
|
the associated DC power supply maintained by
|
|
the environmental monitor card."
|
|
INDEX { ubiEnvMonSupplyIndex, ubiEnvMonSupplyChannelType }
|
|
::= { ubiEnvMonSupplyChannelTable 1 }
|
|
|
|
UbiEnvMonSupplyChannelEntry ::=
|
|
SEQUENCE {
|
|
ubiEnvMonSupplyChannelType INTEGER,
|
|
ubiEnvMonSupplyChannelState UbiEnvMonState
|
|
}
|
|
|
|
ubiEnvMonSupplyChannelType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
dc_48v_a(1),
|
|
dc_48v_b(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique index for the DC power supply channel."
|
|
::= { ubiEnvMonSupplyChannelEntry 1 }
|
|
|
|
|
|
ubiEnvMonSupplyChannelState OBJECT-TYPE
|
|
SYNTAX UbiEnvMonState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current state of the DC power supply channel
|
|
being instrumented.
|
|
Represents the power state of a device being monitored.
|
|
Valid values are:
|
|
|
|
normal(1): the environment is good, such as low
|
|
temperature.
|
|
|
|
notPresent(5): the environmental monitor is not present,
|
|
such as temperature sensors do not exist.
|
|
|
|
notFunctioning(6): the environmental monitor does not
|
|
function properly.
|
|
"
|
|
::= { ubiEnvMonSupplyChannelEntry 2 }
|
|
|
|
|
|
|
|
|
|
-- *****************************************************************
|
|
-- ubiEnvMonMIBNotificationEnables
|
|
-- ****************************************************************
|
|
ubiEnvMonEnableTempStatusChange OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates whether the system
|
|
produces the ubiEnvMonTempStatusChangeNotif.
|
|
A false value prevents temperature notifications
|
|
from being sent by this entity."
|
|
DEFVAL { false }
|
|
::= { ubiEnvMonMIBNotificationEnables 1 }
|
|
|
|
ubiEnvMonEnableFanStatusChange OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates whether the system
|
|
produces the ubiEnvMonFanStatusChangeNotif.
|
|
A false value prevents fan notifications
|
|
from being sent by this entity."
|
|
DEFVAL { false }
|
|
::= { ubiEnvMonMIBNotificationEnables 2 }
|
|
|
|
ubiEnvMonEnableSupplyStatusChange OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates whether the system
|
|
produces the ubiEnvMonSuppStatusChangeNotif.
|
|
A false value prevents redundant supply notifications
|
|
from being generated by this system."
|
|
DEFVAL { false }
|
|
::= { ubiEnvMonMIBNotificationEnables 3 }
|
|
|
|
ubiEnvMonEnableSupplyChannelStatusChange OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates whether the system
|
|
produces the ubiEnvMonSuppExtStatusChangeNotif.
|
|
A false value prevents redundant supply notifications
|
|
from being generated by this system."
|
|
DEFVAL { false }
|
|
::= { ubiEnvMonMIBNotificationEnables 4 }
|
|
|
|
-- *****************************************************************
|
|
-- ubiEnvMonMIBNotificationPrefix
|
|
-- ****************************************************************
|
|
|
|
|
|
-- the following two OBJECT IDENTIFIERS are used to define SNMPv2 Notifications
|
|
-- that are backward compatible with SNMPv1 Traps.
|
|
ubiEnvMonMIBNotifications OBJECT IDENTIFIER ::= { ubiEnvMonMIBNotificationPrefix 0 }
|
|
|
|
|
|
ubiEnvMonTempStatusChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
ubiEnvMonTemperatureDescr,
|
|
ubiEnvMonTemperatureValue,
|
|
ubiEnvMonTemperatureState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ubiEnvMonTempStatusChangeNotif is sent if there
|
|
is change in the state of a device being monitored
|
|
by ubiEnvMonTemperatureState."
|
|
::= { ubiEnvMonMIBNotifications 1 }
|
|
|
|
ubiEnvMonFanStatusChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
ubiEnvMonFanDescr,
|
|
ubiEnvMonFanState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ubiEnvMonFanStatusChangeNotif is sent if there
|
|
is change in the state of a device being monitored
|
|
by ubiEnvMonFanState."
|
|
::= { ubiEnvMonMIBNotifications 2 }
|
|
|
|
ubiEnvMonSupplyStatusChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
ubiEnvMonSupplyDescr,
|
|
ubiEnvMonSupplyState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ubiEnvMonSupplyStatChangeNotif is sent if there
|
|
is change in the state of a device being monitored
|
|
by ubiEnvMonSupplyState."
|
|
::= { ubiEnvMonMIBNotifications 3 }
|
|
|
|
ubiEnvMonSupplyChannelStatusChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
ubiEnvMonSupplyDescr,
|
|
ubiEnvMonSupplyChannelType,
|
|
ubiEnvMonSupplyChannelState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ubiEnvMonSuppExtStatusChangeNotif is sent if there
|
|
is change in the state of a device being monitored
|
|
by ubiEnvMonSupplyExtChannelStatus."
|
|
::= { ubiEnvMonMIBNotifications 4 }
|
|
|
|
|
|
-- *****************************************************************
|
|
-- ubiEnvMonMIBConformance
|
|
-- ****************************************************************
|
|
|
|
-- conformance information
|
|
ubiEnvMonMIBCompliances OBJECT IDENTIFIER ::= { ubiEnvMonMIBConformance 1 }
|
|
ubiEnvMonMIBGroups OBJECT IDENTIFIER ::= { ubiEnvMonMIBConformance 2 }
|
|
|
|
|
|
-- compliance statements
|
|
|
|
ubiEnvMonMIBCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
the Ubiquoss Environmental Monitor MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
ubiEnvMonMIBGroup,
|
|
ubiEnvMonMIBNotifGroup
|
|
}
|
|
GROUP ubiEnvMonMIBGroup
|
|
DESCRIPTION
|
|
"The ubiEnvMonMIBGroup is applicable for implementations which
|
|
need to get the system environment information."
|
|
|
|
GROUP ubiEnvMonMIBNotifGroup
|
|
DESCRIPTION
|
|
"The ubiEnvMonMIBNotifGroup must be
|
|
implemented for system environment that have notification."
|
|
::= { ubiEnvMonMIBCompliances 1 }
|
|
|
|
-- units of conformance
|
|
|
|
ubiEnvMonMIBGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ubiEnvMonTemperatureDescr,
|
|
ubiEnvMonTemperatureValue,
|
|
ubiEnvMonTemperatureHighThreshold,
|
|
ubiEnvMonTemperatureLowThreshold,
|
|
ubiEnvMonTemperatureLastShutdown,
|
|
ubiEnvMonTemperatureState,
|
|
|
|
ubiEnvMonFanDescr,
|
|
ubiEnvMonFanState,
|
|
|
|
ubiEnvMonSupplyDescr,
|
|
ubiEnvMonSupplyState,
|
|
ubiEnvMonSupplySource,
|
|
|
|
ubiEnvMonSupplyExtChannel,
|
|
ubiEnvMonSupplyExtChannelState,
|
|
|
|
ubiEnvMonEnableTempStatusChangeNotif,
|
|
ubiEnvMonEnableFanStatusChangeNotif,
|
|
ubiEnvMonEnableSuppStatusChangeNotif,
|
|
ubiEnvMonEnableSuppExtStatusChangeNotif
|
|
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing environmental
|
|
monitoring capability to a ubi chassis."
|
|
::= { ubiEnvMonMIBGroups 1 }
|
|
|
|
ubiEnvMonMIBNotifGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
ubiEnvMonTempStatusChangeNotif,
|
|
ubiEnvMonFanStatusChangeNotif,
|
|
ubiEnvMonSuppStatusChangeNotif,
|
|
ubiEnvMonSuppExtStatusChangeNotif
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A notification group providing notification
|
|
for environmental monitoring. "
|
|
::= { ubiEnvMonMIBGroups 2 }
|
|
|
|
END
|