2770 lines
87 KiB
Plaintext
2770 lines
87 KiB
Plaintext
WebGraph-Thermo-Hygrometer-US-MIB DEFINITIONS ::= BEGIN
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.39
|
|
----------------------------------------------------------------
|
|
-- 28.06.2018 New:
|
|
-- syntax error corrected
|
|
----------------------------------------------------------------
|
|
|
|
-- 12.12.2017 New:
|
|
-- wtWebGraphThermoHygroMQTTLastWillEnable
|
|
-- wtWebGraphThermoHygroMQTTLastWillTopic
|
|
-- wtWebGraphThermoHygroMQTTLastWillMsg
|
|
-- wtWebGraphThermoHygroMQTTLastWillQoS
|
|
-- wtWebGraphThermoHygroMQTTLastWillRetain
|
|
-- wtWebGraphThermoHygroMQTTLastWillConnectEnable
|
|
-- wtWebGraphThermoHygroMQTTLastWillConnectMsg
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.37
|
|
----------------------------------------------------------------
|
|
-- 07.09.2017 New: wtWebioAnxGraphAlarmManagerPort
|
|
-- wtWebioAnxGraphAlarmMQTT_QoS
|
|
-- wtWebioAnxGraphAlarmMQTT_Retain
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.36
|
|
----------------------------------------------------------------
|
|
-- 09.03.2017 New: wtWebGraphThermoHygroAlarmSensorLostSelection
|
|
-- wtWebGraphThermoHygroAlarmLimitWindow
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.35
|
|
----------------------------------------------------------------
|
|
-- 09.11.2016 New: wtWebGraphThermoHygroMQTT group
|
|
-- HTTP Request, MQTT Alarm, REST
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.34
|
|
----------------------------------------------------------------
|
|
-- 15.07.2015 Changes for new Navigation (__JB__)
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.33
|
|
----------------------------------------------------------------
|
|
-- 28.05.14 New Language Select
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.32
|
|
----------------------------------------------------------------
|
|
-- 11.12.13 Initial Setup
|
|
--
|
|
|
|
|
|
|
|
IMPORTS
|
|
|
|
OBJECT-TYPE FROM RFC-1212
|
|
TRAP-TYPE FROM RFC-1215
|
|
DisplayString, PhysAddress FROM RFC1213-MIB
|
|
enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI;
|
|
|
|
|
|
-- IpAddress ::=
|
|
-- [APPLICATION 0]
|
|
-- IMPLICIT OCTET STRING (SIZE (4))
|
|
-- Counter ::=
|
|
-- [APPLICATION 1]
|
|
-- IMPLICIT INTEGER (0..4294967295)
|
|
-- Gauge ::=
|
|
-- [APPLICATION 2]
|
|
-- IMPLICIT INTEGER (0..4294967295)
|
|
-- TimeTicks ::=
|
|
-- [APPLICATION 3]
|
|
-- IMPLICIT INTEGER (0..4294967295)
|
|
|
|
|
|
-- DisplayString ::= OCTET STRING
|
|
-- PhysAddress ::= OCTET STRING
|
|
|
|
-- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 }
|
|
-- privat OBJECT IDENTIFIER ::= { internet 4 }
|
|
-- enterprises OBJECT IDENTIFIER ::= { privat 1 }
|
|
|
|
|
|
|
|
-- Wiesemann & Theis Com-Server MIB
|
|
|
|
wut OBJECT IDENTIFIER ::= { enterprises 5040 }
|
|
wtComServer OBJECT IDENTIFIER ::= { wut 1 }
|
|
wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 }
|
|
|
|
-- wtWebGraph Tree
|
|
|
|
wtWebGraphThermoHygro OBJECT IDENTIFIER ::= { wtWebio 42 }
|
|
|
|
-- wtWebGraphThermoHygro Tree
|
|
|
|
wtWebGraphThermoHygroTemp OBJECT IDENTIFIER ::= { wtWebGraphThermoHygro 1 }
|
|
wtWebGraphThermoHygroSessCntrl OBJECT IDENTIFIER ::= { wtWebGraphThermoHygro 2 }
|
|
wtWebGraphThermoHygroConfig OBJECT IDENTIFIER ::= { wtWebGraphThermoHygro 3 }
|
|
wtWebGraphThermoHygroDiag OBJECT IDENTIFIER ::= { wtWebGraphThermoHygro 4 }
|
|
|
|
-- wtWebGraphThermoHygroConfig Tree
|
|
|
|
wtWebGraphThermoHygroDevice OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroConfig 1 }
|
|
wtWebGraphThermoHygroPorts OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroConfig 2 }
|
|
wtWebGraphThermoHygroManufact OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroConfig 3 }
|
|
|
|
-- wtWebGraphThermoHygroDevice Tree
|
|
|
|
wtWebGraphThermoHygroText OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroDevice 1 }
|
|
wtWebGraphThermoHygroTimeDate OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroDevice 2 }
|
|
wtWebGraphThermoHygroBasic OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroDevice 3 }
|
|
wtWebGraphThermoHygroDatalogger OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroDevice 4 }
|
|
wtWebGraphThermoHygroAlarm OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroDevice 5 }
|
|
wtWebGraphThermoHygroGraphics OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroDevice 6 }
|
|
|
|
-- wtWebGraphThermoHygroTimeDate Tree
|
|
|
|
wtWebGraphThermoHygroTimeZone OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroTimeDate 1 }
|
|
wtWebGraphThermoHygroTimeServer OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroTimeDate 2 }
|
|
wtWebGraphThermoHygroDeviceClock OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroTimeDate 3 }
|
|
|
|
-- wtWebGraphThermoHygroBasic Tree
|
|
|
|
wtWebGraphThermoHygroNetwork OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 1 }
|
|
wtWebGraphThermoHygroHTTP OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 2 }
|
|
wtWebGraphThermoHygroMail OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 3 }
|
|
wtWebGraphThermoHygroSNMP OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 4 }
|
|
wtWebGraphThermoHygroUDP OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 5 }
|
|
wtWebGraphThermoHygroSyslog OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 6 }
|
|
wtWebGraphThermoHygroFTP OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 7 }
|
|
wtWebGraphThermoHygroRSS OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 8 }
|
|
wtWebGraphThermoHygroLanguage OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 9 }
|
|
wtWebGraphThermoHygroMQTT OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 12 }
|
|
wtWebGraphThermoHygroREST OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroBasic 13 }
|
|
|
|
|
|
-- wtWebGraphThermoHygroGraphics Tree
|
|
|
|
wtWebGraphThermoHygroGraphicsBase OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroGraphics 1 }
|
|
wtWebGraphThermoHygroGraphicsSelect OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroGraphics 2 }
|
|
wtWebGraphThermoHygroGraphicsScale OBJECT IDENTIFIER ::= { wtWebGraphThermoHygroGraphics 3 }
|
|
|
|
-- wtWebGraphThermoHygroTemp Group
|
|
------------------------
|
|
|
|
wtWebGraphThermoHygroSensors OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of sensors"
|
|
::= { wtWebGraphThermoHygroTemp 1 }
|
|
|
|
-- Interface Table
|
|
|
|
wtWebGraphThermoHygroSensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphThermoHygroSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of sensors."
|
|
::= { wtWebGraphThermoHygroTemp 2 }
|
|
|
|
wtWebGraphThermoHygroSensorEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphThermoHygroSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of sensor numbers."
|
|
INDEX { wtWebGraphThermoHygroSensorNo }
|
|
::= { wtWebGraphThermoHygroSensorTable 1 }
|
|
|
|
WtWebGraphThermoHygroSensorEntry ::= SEQUENCE {
|
|
wtWebGraphThermoHygroSensorNo INTEGER
|
|
}
|
|
|
|
wtWebGraphThermoHygroSensorNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor number."
|
|
::= { wtWebGraphThermoHygroSensorEntry 1 }
|
|
|
|
|
|
-- wtWebGraphThermoHygroTempValue Table
|
|
|
|
wtWebGraphThermoHygroTempValueTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphThermoHygroTempValueEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of measurement values corresponding to the channel numbers."
|
|
::= { wtWebGraphThermoHygroTemp 3 }
|
|
|
|
wtWebGraphThermoHygroTempValueEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphThermoHygroTempValueEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Measurement values of the sensors."
|
|
INDEX { wtWebGraphThermoHygroSensorNo }
|
|
::= { wtWebGraphThermoHygroTempValueTable 1 }
|
|
|
|
WtWebGraphThermoHygroTempValueEntry ::= SEQUENCE{
|
|
wtWebGraphThermoHygroTempValue OCTET STRING
|
|
}
|
|
|
|
wtWebGraphThermoHygroTempValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (5))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Measurement value of the sensor, ASCII, 5 characters in length."
|
|
::= { wtWebGraphThermoHygroTempValueEntry 1 }
|
|
|
|
-- wtWebGraphThermoHygroBinaryTempValue Table
|
|
|
|
wtWebGraphThermoHygroBinaryTempValueTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphThermoHygroBinaryTempValueEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of binary measurement values corresponding to the channel numbers."
|
|
::= { wtWebGraphThermoHygroTemp 4 }
|
|
|
|
wtWebGraphThermoHygroBinaryTempValueEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphThermoHygroBinaryTempValueEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary measurement values of the sensors."
|
|
INDEX { wtWebGraphThermoHygroSensorNo }
|
|
::= { wtWebGraphThermoHygroBinaryTempValueTable 1 }
|
|
|
|
WtWebGraphThermoHygroBinaryTempValueEntry ::= SEQUENCE{
|
|
wtWebGraphThermoHygroBinaryTempValue INTEGER
|
|
}
|
|
|
|
wtWebGraphThermoHygroBinaryTempValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary measurement value of the sensor in 1/10 degrees Celsius or 1/10 per cent,
|
|
signed number, 0x4FFF6 indicates an
|
|
invalid measured value."
|
|
::= { wtWebGraphThermoHygroBinaryTempValueEntry 1 }
|
|
|
|
-- wtWebGraphThermoHygroTempValuePkt Table
|
|
|
|
wtWebGraphThermoHygroTempValuePktTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphThermoHygroTempValuePktEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of measurement values corresponding to the channel numbers."
|
|
::= { wtWebGraphThermoHygroTemp 8 }
|
|
|
|
wtWebGraphThermoHygroTempValuePktEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphThermoHygroTempValuePktEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Measurement values of the sensors."
|
|
INDEX { wtWebGraphThermoHygroSensorNo }
|
|
::= { wtWebGraphThermoHygroTempValuePktTable 1 }
|
|
|
|
WtWebGraphThermoHygroTempValuePktEntry ::= SEQUENCE{
|
|
wtWebGraphThermoHygroTempValuePkt OCTET STRING
|
|
}
|
|
|
|
wtWebGraphThermoHygroTempValuePkt OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (5))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Measurement value of the sensor, ASCII, 5 characters in length, delimeter is decimal point."
|
|
::= { wtWebGraphThermoHygroTempValuePktEntry 1 }
|
|
|
|
-- wtWebGraphThermoHygroSessCntrl Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoHygroSessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtWebGraphThermoHygroSessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtWebGraphThermoHygroSessCntrl 1 }
|
|
|
|
wtWebGraphThermoHygroSessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphThermoHygroSessCntrl-NoSession(0),
|
|
wtWebGraphThermoHygroSessCntrl-Session(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the
|
|
password was written, the device is already in config mode and the
|
|
variables can only be read."
|
|
::= { wtWebGraphThermoHygroSessCntrl 2 }
|
|
|
|
wtWebGraphThermoHygroSessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again.
|
|
When read this variable provides the value 0."
|
|
::= { wtWebGraphThermoHygroSessCntrl 3 }
|
|
|
|
wtWebGraphThermoHygroSessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtWebGraphThermoHygroSessCntrl 4 }
|
|
|
|
wtWebGraphThermoHygroSessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtWebGraphThermoHygroSessCntrl 5 }
|
|
|
|
|
|
-- wtWebGraphThermoHygroText Group
|
|
------------------------
|
|
|
|
wtWebGraphThermoHygroDeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtWebGraphThermoHygroText 1 }
|
|
|
|
wtWebGraphThermoHygroDeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtWebGraphThermoHygroText 2 }
|
|
|
|
wtWebGraphThermoHygroDeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtWebGraphThermoHygroText 3 }
|
|
|
|
wtWebGraphThermoHygroDeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtWebGraphThermoHygroText 4 }
|
|
|
|
-- wtWebGraphThermoHygroTimeZone Group
|
|
----------------------------
|
|
|
|
wtWebGraphThermoHygroTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebGraphThermoHygroTimeZone 1 }
|
|
|
|
wtWebGraphThermoHygroTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebGraphThermoHygroTimeZone 2 }
|
|
|
|
wtWebGraphThermoHygroTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtWebGraphThermoHygroTimeZone 3 }
|
|
|
|
wtWebGraphThermoHygroStTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebGraphThermoHygroTimeZone 4 }
|
|
|
|
wtWebGraphThermoHygroStTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebGraphThermoHygroTimeZone 5 }
|
|
|
|
wtWebGraphThermoHygroStTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtWebGraphThermoHygroTimeZone 6 }
|
|
|
|
wtWebGraphThermoHygroStTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphThermoHygroStartMonth-January(1),
|
|
wtWebGraphThermoHygroStartMonth-February(2),
|
|
wtWebGraphThermoHygroStartMonth-March(3),
|
|
wtWebGraphThermoHygroStartMonth-April(4),
|
|
wtWebGraphThermoHygroStartMonth-May(5),
|
|
wtWebGraphThermoHygroStartMonth-June(6),
|
|
wtWebGraphThermoHygroStartMonth-July(7),
|
|
wtWebGraphThermoHygroStartMonth-August(8),
|
|
wtWebGraphThermoHygroStartMonth-September(9),
|
|
wtWebGraphThermoHygroStartMonth-October(10),
|
|
wtWebGraphThermoHygroStartMonth-November(11),
|
|
wtWebGraphThermoHygroStartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtWebGraphThermoHygroTimeZone 7 }
|
|
|
|
wtWebGraphThermoHygroStTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphThermoHygroStartMode-first(1),
|
|
wtWebGraphThermoHygroStartMode-second(2),
|
|
wtWebGraphThermoHygroStartMode-third(3),
|
|
wtWebGraphThermoHygroStartMode-fourth(4),
|
|
wtWebGraphThermoHygroStartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtWebGraphThermoHygroTimeZone 8 }
|
|
|
|
wtWebGraphThermoHygroStTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphThermoHygroStartWday-Sunday(1),
|
|
wtWebGraphThermoHygroStartWday-Monday(2),
|
|
wtWebGraphThermoHygroStartWday-Tuesday(3),
|
|
wtWebGraphThermoHygroStartWday-Thursday(4),
|
|
wtWebGraphThermoHygroStartWday-Wednesday(5),
|
|
wtWebGraphThermoHygroStartWday-Friday(6),
|
|
wtWebGraphThermoHygroStartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtWebGraphThermoHygroTimeZone 9 }
|
|
|
|
wtWebGraphThermoHygroStTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebGraphThermoHygroTimeZone 10 }
|
|
|
|
wtWebGraphThermoHygroStTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebGraphThermoHygroTimeZone 11 }
|
|
|
|
wtWebGraphThermoHygroStTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphThermoHygroStopMonth-January(1),
|
|
wtWebGraphThermoHygroStopMonth-February(2),
|
|
wtWebGraphThermoHygroStopMonth-March(3),
|
|
wtWebGraphThermoHygroStopMonth-April(4),
|
|
wtWebGraphThermoHygroStopMonth-May(5),
|
|
wtWebGraphThermoHygroStopMonth-June(6),
|
|
wtWebGraphThermoHygroStopMonth-July(7),
|
|
wtWebGraphThermoHygroStopMonth-August(8),
|
|
wtWebGraphThermoHygroStopMonth-September(9),
|
|
wtWebGraphThermoHygroStopMonth-October(10),
|
|
wtWebGraphThermoHygroStopMonth-November(11),
|
|
wtWebGraphThermoHygroStopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtWebGraphThermoHygroTimeZone 12 }
|
|
|
|
wtWebGraphThermoHygroStTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphThermoHygroStopMode-first(1),
|
|
wtWebGraphThermoHygroStopMode-second(2),
|
|
wtWebGraphThermoHygroStopMode-third(3),
|
|
wtWebGraphThermoHygroStopMode-fourth(4),
|
|
wtWebGraphThermoHygroStopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtWebGraphThermoHygroTimeZone 13 }
|
|
|
|
wtWebGraphThermoHygroStTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphThermoHygroStopWday-Sunday(1),
|
|
wtWebGraphThermoHygroStopWday-Monday(2),
|
|
wtWebGraphThermoHygroStopWday-Tuesday(3),
|
|
wtWebGraphThermoHygroStopWday-Thursday(4),
|
|
wtWebGraphThermoHygroStopWday-Wednesday(5),
|
|
wtWebGraphThermoHygroStopWday-Friday(6),
|
|
wtWebGraphThermoHygroStopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtWebGraphThermoHygroTimeZone 14 }
|
|
|
|
wtWebGraphThermoHygroStTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebGraphThermoHygroTimeZone 15 }
|
|
|
|
wtWebGraphThermoHygroStTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebGraphThermoHygroTimeZone 16 }
|
|
|
|
-- wtWebGraphThermoHygroTimeServer Group
|
|
----------------------------
|
|
|
|
wtWebGraphThermoHygroTimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtWebGraphThermoHygroTimeServer 1 }
|
|
|
|
wtWebGraphThermoHygroTimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtWebGraphThermoHygroTimeServer 2 }
|
|
|
|
wtWebGraphThermoHygroTsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtWebGraphThermoHygroTimeServer 3 }
|
|
|
|
wtWebGraphThermoHygroTsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtWebGraphThermoHygroTimeServer 4 }
|
|
|
|
-- wtWebGraphThermoHygroDeviceClock Group
|
|
----------------------------
|
|
|
|
wtWebGraphThermoHygroClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtWebGraphThermoHygroDeviceClock 1 }
|
|
|
|
wtWebGraphThermoHygroClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtWebGraphThermoHygroDeviceClock 2 }
|
|
|
|
wtWebGraphThermoHygroClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtWebGraphThermoHygroDeviceClock 3 }
|
|
|
|
wtWebGraphThermoHygroClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphThermoHygroClockMonth-January(1),
|
|
wtWebGraphThermoHygroClockMonth-February(2),
|
|
wtWebGraphThermoHygroClockMonth-March(3),
|
|
wtWebGraphThermoHygroClockMonth-April(4),
|
|
wtWebGraphThermoHygroClockMonth-May(5),
|
|
wtWebGraphThermoHygroClockMonth-June(6),
|
|
wtWebGraphThermoHygroClockMonth-July(7),
|
|
wtWebGraphThermoHygroClockMonth-August(8),
|
|
wtWebGraphThermoHygroClockMonth-September(9),
|
|
wtWebGraphThermoHygroClockMonth-October(10),
|
|
wtWebGraphThermoHygroClockMonth-November(11),
|
|
wtWebGraphThermoHygroClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtWebGraphThermoHygroDeviceClock 4 }
|
|
|
|
wtWebGraphThermoHygroClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtWebGraphThermoHygroDeviceClock 5 }
|
|
|
|
|
|
-- wtWebGraphThermoHygroNetwork Group
|
|
------------------------
|
|
|
|
wtWebGraphThermoHygroIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtWebGraphThermoHygroNetwork 1 }
|
|
|
|
wtWebGraphThermoHygroSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtWebGraphThermoHygroNetwork 2 }
|
|
|
|
wtWebGraphThermoHygroGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtWebGraphThermoHygroNetwork 3 }
|
|
|
|
wtWebGraphThermoHygroDnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtWebGraphThermoHygroNetwork 4 }
|
|
|
|
wtWebGraphThermoHygroDnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtWebGraphThermoHygroNetwork 5 }
|
|
|
|
wtWebGraphThermoHygroAddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP disable
|
|
Bit 0: BOOTP disable
|
|
"
|
|
::= { wtWebGraphThermoHygroNetwork 6 }
|
|
|
|
-- wtWebGraphThermoHygroHTTP Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoHygroStartup OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded start page:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: Index.htm
|
|
Bit 2: Home.htm
|
|
Bit 3: User.htm
|
|
Only one page may be selected at a time."
|
|
::= { wtWebGraphThermoHygroHTTP 1 }
|
|
|
|
wtWebGraphThermoHygroGetHeaderEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If these bits are set, every answer of a short form GET question will be lead
|
|
by the IP-address and name of the device and/or a HTTP header:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-6: unused
|
|
Bit 1 : GET HTTP enable
|
|
Bit 0 : GET Header enable"
|
|
::= { wtWebGraphThermoHygroHTTP 2 }
|
|
|
|
wtWebGraphThermoHygroHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtWebGraphThermoHygroHTTP 3 }
|
|
|
|
|
|
-- wtWebGraphThermoHygroMail Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoHygroMailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtWebGraphThermoHygroMail 1 }
|
|
|
|
wtWebGraphThermoHygroMailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtWebGraphThermoHygroMail 2 }
|
|
|
|
wtWebGraphThermoHygroMailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtWebGraphThermoHygroMail 3 }
|
|
|
|
wtWebioAn1MailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtWebGraphThermoHygroMail 4 }
|
|
|
|
wtWebGraphThermoHygroMailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtWebGraphThermoHygroMail 5 }
|
|
|
|
wtWebGraphThermoHygroMailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtWebGraphThermoHygroMail 6 }
|
|
|
|
wtWebGraphThermoHygroMailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtWebGraphThermoHygroMail 7 }
|
|
|
|
wtWebGraphThermoHygroMailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtWebGraphThermoHygroMail 8 }
|
|
|
|
-- wtWebGraphThermoHygroSNMP Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoHygroSnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtWebGraphThermoHygroSNMP 1 }
|
|
|
|
wtWebGraphThermoHygroSnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtWebGraphThermoHygroSNMP 2 }
|
|
|
|
wtWebGraphThermoHygroSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtWebGraphThermoHygroSNMP 3 }
|
|
|
|
wtWebGraphThermoHygroSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphThermoHygroSNMP 4 }
|
|
|
|
wtWebGraphThermoHygroSnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtWebGraphThermoHygroSNMP 5 }
|
|
|
|
wtWebGraphThermoHygroSnmpCommunityStringTrap OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string send within traps."
|
|
::= { wtWebGraphThermoHygroSNMP 6 }
|
|
|
|
wtWebGraphThermoHygroSnmpSystemTrapManagerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP server which accepts the system trap."
|
|
::= { wtWebGraphThermoHygroSNMP 7 }
|
|
|
|
-- wtWebGraphThermoHygroUDP Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoHygroUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtWebGraphThermoHygroUDP 1 }
|
|
|
|
wtWebGraphThermoHygroUdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtWebGraphThermoHygroUDP 2 }
|
|
|
|
-- wtWebGraphThermoHygroSyslog Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoHygroSyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtWebGraphThermoHygroSyslog 1 }
|
|
|
|
wtWebGraphThermoHygroSyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtWebGraphThermoHygroSyslog 2 }
|
|
|
|
wtWebGraphThermoHygroSyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebGraphThermoHygroSyslog 3 }
|
|
|
|
wtWebGraphThermoHygroSyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtWebGraphThermoHygroSyslog 4 }
|
|
|
|
-- wtWebGraphThermoHygroFTP Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoHygroFTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtWebGraphThermoHygroFTP 1 }
|
|
|
|
wtWebGraphThermoHygroFTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebGraphThermoHygroFTP 2 }
|
|
|
|
wtWebGraphThermoHygroFTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtWebGraphThermoHygroFTP 3 }
|
|
|
|
wtWebGraphThermoHygroFTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtWebGraphThermoHygroFTP 4 }
|
|
|
|
wtWebGraphThermoHygroFTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtWebGraphThermoHygroFTP 5 }
|
|
|
|
wtWebGraphThermoHygroFTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtWebGraphThermoHygroFTP 6 }
|
|
|
|
wtWebGraphThermoHygroFTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtWebGraphThermoHygroFTP 7 }
|
|
|
|
-- wtWebGraphThermoHygroLanguage Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoHygroLanguageSelect OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sprachauswahl:
|
|
Octet 1: ungenutzt
|
|
Octet 2: ungenutzt
|
|
Octet 3: ungenutzt
|
|
Octet 4:
|
|
Bit 2-7: ungenutzt
|
|
Bit 1 : Englisch
|
|
Bit 0 : Deutsch"
|
|
::= { wtWebGraphThermoHygroLanguage 1 }
|
|
|
|
-- wtWebGraphThermoHygroMQTT Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoHygroMQTTEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 7 schaltet MQTT frei:
|
|
Octet 1: ungenutzt
|
|
Octet 2: ungenutzt
|
|
Octet 3: ungenutzt
|
|
Octet 4:
|
|
Bit 0-6: ungenutzt
|
|
Bit 7 : MQTT enable"
|
|
::= { wtWebGraphThermoHygroMQTT 1 }
|
|
|
|
wtWebGraphThermoHygroMQTTBrockerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP-address of the MQTT-Server."
|
|
::= { wtWebGraphThermoHygroMQTT 2 }
|
|
|
|
wtWebGraphThermoHygroMQTTUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT login user name."
|
|
::= { wtWebGraphThermoHygroMQTT 3 }
|
|
|
|
wtWebGraphThermoHygroMQTTPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT login password."
|
|
::= { wtWebGraphThermoHygroMQTT 4 }
|
|
|
|
wtWebGraphThermoHygroMQTTLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local port number."
|
|
::= { wtWebGraphThermoHygroMQTT 5 }
|
|
|
|
wtWebGraphThermoHygroMQTTBrokerServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Server port number."
|
|
::= { wtWebGraphThermoHygroMQTT 6 }
|
|
|
|
wtWebGraphThermoHygroMQTTInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ping intervall, if no data has to be send: time in seconds."
|
|
::= { wtWebGraphThermoHygroMQTT 7 }
|
|
|
|
wtWebGraphThermoHygroMQTTLastWillEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activate MQTT LastWill message:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : MQTT Last will enable"
|
|
::= { wtWebGraphThermoHygroMQTT 8 }
|
|
|
|
wtWebGraphThermoHygroMQTTLastWillTopic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Last Will Topic."
|
|
::= { wtWebGraphThermoHygroMQTT 9 }
|
|
|
|
wtWebGraphThermoHygroMQTTLastWillMsg OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Last Will message."
|
|
::= { wtWebGraphThermoHygroMQTT 10 }
|
|
|
|
wtWebGraphThermoHygroMQTTLastWillQoS OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded MQTT Publish QoS:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: QoS 0
|
|
Bit 1: QoS 1
|
|
Bit 2: QoS 2
|
|
Bit 3-7:unused"
|
|
::= { wtWebGraphThermoHygroMQTT 11 }
|
|
|
|
wtWebGraphThermoHygroMQTTLastWillRetain OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded MQTT Publish Retain properties:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : retain enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebGraphThermoHygroMQTT 12 }
|
|
|
|
wtWebGraphThermoHygroMQTTLastWillConnectEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activate MQTT LastWill Connect message:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : MQTT Last will connect message enable"
|
|
::= { wtWebGraphThermoHygroMQTT 13 }
|
|
|
|
wtWebGraphThermoHygroMQTTLastWillConnectMsg OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Last Will Connect message will be send with the QoS and Retain settings
|
|
of the LastWill message."
|
|
::= { wtWebGraphThermoHygroMQTT 14 }
|
|
|
|
|
|
-- wtWebGraphThermoHygroREST Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoHygroRESTEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activates REST :
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : REST enable"
|
|
::= { wtWebGraphThermoHygroREST 1 }
|
|
|
|
wtWebGraphThermoHygroRESTDigestAuthEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activates Digest-Authentification:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Digest Auth enable"
|
|
::= { wtWebGraphThermoHygroREST 2 }
|
|
|
|
-- wtWebGraphThermoHygroDatalogger Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoHygroLoggerTimebase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphThermoHygroDatalogger-1Min(1),
|
|
wtWebGraphThermoHygroDatalogger-5Min(2),
|
|
wtWebGraphThermoHygroDatalogger-15Min(3),
|
|
wtWebGraphThermoHygroDatalogger-60Min(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time base of the data logger"
|
|
::= { wtWebGraphThermoHygroDatalogger 1 }
|
|
|
|
wtWebGraphThermoHygroLoggerSensorSel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Sensor 1
|
|
Bit 1: Sensor 2
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphThermoHygroDatalogger 2 }
|
|
|
|
-- wtWebGraphThermoHygroRSS Group
|
|
--------------------------------
|
|
|
|
wtWebGraphThermoHygroRSSChannelTitle OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the RSS Feed."
|
|
::= { wtWebGraphThermoHygroRSS 1 }
|
|
|
|
wtWebGraphThermoHygroRSSChannelLink OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Link of the RSS Feed."
|
|
::= { wtWebGraphThermoHygroRSS 2 }
|
|
|
|
wtWebGraphThermoHygroRSSChannelDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the RSS Feed."
|
|
::= { wtWebGraphThermoHygroRSS 3 }
|
|
|
|
wtWebGraphThermoHygroRSSChannelImage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Link of a picture, which will be shown at the headline of the output window."
|
|
::= { wtWebGraphThermoHygroRSS 4 }
|
|
|
|
wtWebGraphThermoHygroRSSChannelImageTitle OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alias Name of the picture."
|
|
::= { wtWebGraphThermoHygroRSS 5 }
|
|
|
|
wtWebGraphThermoHygroRSSChannelImageLink OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Link, which can be selected by clicking on the picture."
|
|
::= { wtWebGraphThermoHygroRSS 6 }
|
|
|
|
wtWebGraphThermoHygroRSSChannelItemTitle OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Title of the RSS Feed."
|
|
::= { wtWebGraphThermoHygroRSS 7 }
|
|
|
|
wtWebGraphThermoHygroRSSChannelItemLink OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Link of the RSS Feed."
|
|
::= { wtWebGraphThermoHygroRSS 8 }
|
|
|
|
wtWebGraphThermoHygroRSSChannelItemDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Text of the RSS Feed."
|
|
::= { wtWebGraphThermoHygroRSS 9 }
|
|
|
|
wtWebGraphThermoHygroRSSChannelItemQuantity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of lines."
|
|
::= { wtWebGraphThermoHygroRSS 10 }
|
|
|
|
-- wtWebGraphThermoHygroAlarm Group
|
|
----------------------------
|
|
|
|
wtWebGraphThermoHygroAlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtWebGraphThermoHygroAlarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtWebGraphThermoHygroAlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphThermoHygroAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtWebGraphThermoHygroAlarm 2 }
|
|
|
|
wtWebGraphThermoHygroAlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphThermoHygroAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtWebGraphThermoHygroAlarmNo }
|
|
::= { wtWebGraphThermoHygroAlarmIfTable 1 }
|
|
|
|
WtWebGraphThermoHygroAlarmIfEntry ::= SEQUENCE {
|
|
wtWebGraphThermoHygroAlarmNo INTEGER
|
|
}
|
|
|
|
wtWebGraphThermoHygroAlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm number."
|
|
::= { wtWebGraphThermoHygroAlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtWebGraphThermoHygroAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphThermoHygroAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtWebGraphThermoHygroAlarm 3 }
|
|
|
|
wtWebGraphThermoHygroAlarmEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphThermoHygroAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtWebGraphThermoHygroAlarmNo }
|
|
::= { wtWebGraphThermoHygroAlarmTable 1 }
|
|
|
|
WtWebGraphThermoHygroAlarmEntry ::= SEQUENCE {
|
|
wtWebGraphThermoHygroAlarmTrigger OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmMin OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmMax OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmHysteresis OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmDelay OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmInterval OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmEnable OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmEMailAddr OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmMailSubject OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmMailText OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmManagerIP OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmTrapText OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmMailOptions OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmTcpIpAddr OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmTcpPort INTEGER,
|
|
wtWebGraphThermoHygroAlarmTcpText OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmClearMailSubject OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmClearMailText OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmClearTrapText OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmClearTcpText OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmDeltaTemp OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmRHMin OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmRHMax OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmRHHysteresis OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmAHMin OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmAHMax OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmSyslogIpAddr OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmSyslogPort INTEGER,
|
|
wtWebGraphThermoHygroAlarmSyslogText OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmSyslogClearText OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmFtpDataPort OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmFtpFileName OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmFtpText OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmFtpClearText OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmFtpOption OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmTimerCron OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmName OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmActive OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmHttpReqAuthEnable OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmHttpReqAuthUser OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmHttpReqAuthPassword OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmHttpReqSetUrl OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmHttpReqClearUrl OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmHttpReqServerPort INTEGER,
|
|
wtWebGraphThermoHygroAlarmMqttTopicPath OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmMqttTopicSetTopic OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmMqttTopicClear OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmSensorLostSelection OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmLimitWindow OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmSnmpManagerPort INTEGER,
|
|
wtWebGraphThermoHygroAlarmMqttQoS OCTET STRING,
|
|
wtWebGraphThermoHygroAlarmMqttRetain OCTET STRING
|
|
}
|
|
|
|
wtWebGraphThermoHygroAlarmTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3:
|
|
Bit 0: Timer
|
|
Bit 1: ColdStart
|
|
Bit 2: WarmStart
|
|
|
|
Octet 4:
|
|
Bit 0: Sensor 1
|
|
Bit 1: Sensor 2
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 1 }
|
|
|
|
wtWebGraphThermoHygroAlarmMin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum temperature in degrees with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 2 }
|
|
|
|
wtWebGraphThermoHygroAlarmMax OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum temperature in degrees with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 3 }
|
|
|
|
wtWebGraphThermoHygroAlarmHysteresis OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
|
|
, in degrees with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 4 }
|
|
|
|
wtWebGraphThermoHygroAlarmDelay OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm will be delayed by setting this time while stable alarm
|
|
condition occur (time in minutes)."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 5 }
|
|
|
|
|
|
wtWebGraphThermoHygroAlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 6 }
|
|
|
|
wtWebGraphThermoHygroAlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: TCP Client enable"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 7 }
|
|
|
|
wtWebGraphThermoHygroAlarmEMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 8 }
|
|
|
|
wtWebGraphThermoHygroAlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 9 }
|
|
|
|
wtWebGraphThermoHygroAlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text: <Tn> provides the current temperature; n = 1..8.
|
|
<Z> provides the current time."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 10 }
|
|
|
|
wtWebGraphThermoHygroAlarmManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the SNMP Manager which accepts the trap."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 11 }
|
|
|
|
wtWebGraphThermoHygroAlarmTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text is sent in the trap body."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 12 }
|
|
|
|
wtWebGraphThermoHygroAlarmMailOptions OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : Attach Thermo.csv Enable
|
|
Bit 1 : CSV-Data_since_last_report
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 13 }
|
|
|
|
wtWebGraphThermoHygroAlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the trap."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 14 }
|
|
|
|
wtWebGraphThermoHygroAlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP server which accepts the trap."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 15 }
|
|
|
|
wtWebGraphThermoHygroAlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text is sent in the TCP trap body."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 16 }
|
|
|
|
wtWebGraphThermoHygroAlarmClearMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm clear mail."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 17 }
|
|
|
|
wtWebGraphThermoHygroAlarmClearMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm clear mail text: <Tn> provides the current temperature; n = 1..8.
|
|
<Z> provides the current time."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 18 }
|
|
|
|
wtWebGraphThermoHygroAlarmClearTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text is sent in the trap body."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 19 }
|
|
|
|
wtWebGraphThermoHygroAlarmClearTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text is sent in the TCP trap body."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 20 }
|
|
|
|
wtWebGraphThermoHygroAlarmDeltaTemp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum rate of change degrees/min with maximum 2 decimal places.
|
|
Compared with the average of a period of 5 minutes."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 21 }
|
|
|
|
wtWebGraphThermoHygroAlarmRHMin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum rel. Humidity in percent with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 22 }
|
|
|
|
wtWebGraphThermoHygroAlarmRHMax OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum rel.Humidity in percent with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 23 }
|
|
|
|
wtWebGraphThermoHygroAlarmRHHysteresis OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hysterese rel. Humidity in percent with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 24 }
|
|
|
|
wtWebGraphThermoHygroAlarmAHMin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum abs. Humidity in g/(m*m*m) with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 25 }
|
|
|
|
wtWebGraphThermoHygroAlarmAHMax OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum abs. Humidity in g/(m*m*m) with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 26 }
|
|
|
|
wtWebGraphThermoHygroAlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 27 }
|
|
|
|
wtWebGraphThermoHygroAlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 28 }
|
|
|
|
wtWebGraphThermoHygroAlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 29 }
|
|
|
|
wtWebGraphThermoHygroAlarmSyslogClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 30 }
|
|
|
|
wtWebGraphThermoHygroAlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 31 }
|
|
|
|
wtWebGraphThermoHygroAlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 32 }
|
|
|
|
wtWebGraphThermoHygroAlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 33 }
|
|
|
|
wtWebGraphThermoHygroAlarmFtpClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm clear message to store on the FTP server."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 34 }
|
|
|
|
wtWebGraphThermoHygroAlarmFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 35 }
|
|
|
|
wtWebGraphThermoHygroAlarmTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a message, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 36 }
|
|
|
|
-- __JB__
|
|
wtWebGraphThermoHygroAlarmName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alert name"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 39 }
|
|
|
|
-- __JB__
|
|
wtWebGraphThermoHygroAlarmActive OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alert active
|
|
1 = ON
|
|
0 = OFF"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 40 }
|
|
|
|
wtWebGraphThermoHygroAlarmHttpReqAuthEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : HHTP Request Authentication enable"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 61 }
|
|
|
|
wtWebGraphThermoHygroAlarmHttpReqAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: User"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 62 }
|
|
|
|
wtWebGraphThermoHygroAlarmHttpReqAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Password"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 63 }
|
|
|
|
wtWebGraphThermoHygroAlarmHttpReqSetUrl OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Set URL"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 64 }
|
|
|
|
wtWebGraphThermoHygroAlarmHttpReqClearUrl OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Clear URL"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 65 }
|
|
|
|
wtWebGraphThermoHygroAlarmHttpReqServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Server Port"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 66 }
|
|
|
|
wtWebGraphThermoHygroAlarmMqttTopicPath OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Publish: Topic path"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 67 }
|
|
|
|
wtWebGraphThermoHygroAlarmMqttTopicSetTopic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Publish: Topic SET message"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 68 }
|
|
|
|
wtWebGraphThermoHygroAlarmMqttTopicClear OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Publish: Topic CLEAR message"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 69 }
|
|
|
|
wtWebGraphThermoHygroAlarmSensorLostSelection OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : Sensor 1
|
|
Bit 0 : Sensor 0"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 70 }
|
|
|
|
wtWebGraphThermoHygroAlarmLimitWindow OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If window type is INSIDE the alarm is genereted when the temperature
|
|
is greater minumum value and lower than maximum value. If window type is OUTSIDE
|
|
the alarm is generated when the measured value is lower than the minimum value
|
|
or greater than the maximum value.
|
|
Binary coded options, select only one option at the same time:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : inside window
|
|
Bit 0 : outside window"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 71 }
|
|
|
|
wtWebGraphThermoHygroAlarmSnmpManagerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebGraphThermoHygroAlarmEntry 76 }
|
|
|
|
wtWebGraphThermoHygroAlarmMqttQoS OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded value:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: QoS 0
|
|
Bit 1: QoS 1
|
|
Bit 2: QoS 2
|
|
Bit 3-7:unused"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 77 }
|
|
|
|
wtWebGraphThermoHygroAlarmMqttRetain OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded value:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : retain enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebGraphThermoHygroAlarmEntry 78 }
|
|
|
|
-- wtWebGraphThermoHygroGraphicsBase Group
|
|
----------------------------
|
|
|
|
wtWebGraphThermoHygroGraphicsBaseEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the viewing options of the graphic:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : Auto scroll enable
|
|
Bit 1 : Show table
|
|
Bit 2 : Show graph
|
|
Bit 3 : Show control buttons
|
|
Bit 4 : Show config menu
|
|
Bit 5-7: unused"
|
|
::= { wtWebGraphThermoHygroGraphicsBase 1 }
|
|
|
|
wtWebGraphThermoHygroGraphicsBaseWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the width of the graphic in pixels."
|
|
::= { wtWebGraphThermoHygroGraphicsBase 2 }
|
|
|
|
wtWebGraphThermoHygroGraphicsBaseHeight OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the height of the graphic in pixels."
|
|
::= { wtWebGraphThermoHygroGraphicsBase 3 }
|
|
|
|
wtWebGraphThermoHygroGraphicsBaseFrameColor OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(3))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Frame color definition in RGB."
|
|
::= { wtWebGraphThermoHygroGraphicsBase 4 }
|
|
|
|
wtWebGraphThermoHygroGraphicsBaseBackgroundColor OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(3))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Background color definition in RGB."
|
|
::= { wtWebGraphThermoHygroGraphicsBase 5 }
|
|
|
|
wtWebGraphThermoHygroGraphicsBasePollingrate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the pollingrate in seconds,
|
|
which defines the refreshing intervall of the graphic."
|
|
::= { wtWebGraphThermoHygroGraphicsBase 6 }
|
|
|
|
-- wtWebGraphThermoHygroGraphicsSelect Group
|
|
----------------------------
|
|
|
|
wtWebGraphThermoHygroGraphicsSelectDisplaySensorSel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded sensor selection:
|
|
only selected sensors will be shown in the graphical presentation:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Sensor 1
|
|
Bit 1: Sensor 2
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphThermoHygroGraphicsSelect 1 }
|
|
|
|
wtWebGraphThermoHygroGraphicsSelectDisplayShowExtrem OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded sensor selection:
|
|
only selected sensors will be shown with minima and maxima:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Sensor 1
|
|
Bit 1: Sensor 2
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphThermoHygroGraphicsSelect 2 }
|
|
|
|
-- Graph Sensor Color Table
|
|
|
|
wtWebGraphThermoHygroSensorColorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphThermoHygroSensorColorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of sensor colors for the praphical presentation."
|
|
::= { wtWebGraphThermoHygroGraphicsSelect 3 }
|
|
|
|
wtWebGraphThermoHygroSensorColorEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphThermoHygroSensorColorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the sensors."
|
|
INDEX { wtWebGraphThermoHygroSensorNo }
|
|
::= { wtWebGraphThermoHygroSensorColorTable 1 }
|
|
|
|
WtWebGraphThermoHygroSensorColorEntry ::= SEQUENCE {
|
|
wtWebGraphThermoHygroGraphicsSensorColor OCTET STRING,
|
|
wtWebGraphThermoHygroGraphicsSelectScale OCTET STRING
|
|
}
|
|
|
|
wtWebGraphThermoHygroGraphicsSensorColor OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(3))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Color of the sensors at the praphical presention."
|
|
::= { wtWebGraphThermoHygroSensorColorEntry 1 }
|
|
|
|
wtWebGraphThermoHygroGraphicsSelectScale OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Assignes one of 4 scales to a sensor:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : Use Scale 1
|
|
Bit 1 : Use Scale 2
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphThermoHygroSensorColorEntry 2 }
|
|
|
|
-- wtWebGraphThermoHygroGraphicsScale Group
|
|
----------------------------
|
|
|
|
wtWebGraphThermoHygroGraphicsScaleAutoScaleEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Select the Auto Scale Mode:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : Scale 1 Auto scale enable
|
|
Bit 1 : Scale 2 Auto scale enable
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphThermoHygroGraphicsScale 1 }
|
|
|
|
|
|
wtWebGraphThermoHygroGraphicsScaleAutoFitEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Select the Auto Fit Mode::
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : Scale 1 Auto fit enable
|
|
Bit 1 : Scale 2 Auto fit enable
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphThermoHygroGraphicsScale 2 }
|
|
|
|
wtWebGraphThermoHygroGraphicsScale1Min OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 1: Minimum."
|
|
::= { wtWebGraphThermoHygroGraphicsScale 3 }
|
|
|
|
wtWebGraphThermoHygroGraphicsScale2Min OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 2: Minimum."
|
|
::= { wtWebGraphThermoHygroGraphicsScale 4 }
|
|
|
|
wtWebGraphThermoHygroGraphicsScale3Min OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 3: Minimum."
|
|
::= { wtWebGraphThermoHygroGraphicsScale 5 }
|
|
|
|
wtWebGraphThermoHygroGraphicsScale4Min OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 4: Minimum."
|
|
::= { wtWebGraphThermoHygroGraphicsScale 6 }
|
|
|
|
wtWebGraphThermoHygroGraphicsScale1Max OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 1: Maximum."
|
|
::= { wtWebGraphThermoHygroGraphicsScale 7 }
|
|
|
|
wtWebGraphThermoHygroGraphicsScale2Max OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 2: Maximum."
|
|
::= { wtWebGraphThermoHygroGraphicsScale 8 }
|
|
|
|
wtWebGraphThermoHygroGraphicsScale3Max OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 3: Maximum."
|
|
::= { wtWebGraphThermoHygroGraphicsScale 9 }
|
|
|
|
wtWebGraphThermoHygroGraphicsScale4Max OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 4: Maximum."
|
|
::= { wtWebGraphThermoHygroGraphicsScale 10 }
|
|
|
|
wtWebGraphThermoHygroGraphicsScale1Unit OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 1: Unit."
|
|
::= { wtWebGraphThermoHygroGraphicsScale 11 }
|
|
|
|
wtWebGraphThermoHygroGraphicsScale2Unit OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 2: Unit."
|
|
::= { wtWebGraphThermoHygroGraphicsScale 12 }
|
|
|
|
wtWebGraphThermoHygroGraphicsScale3Unit OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 3: Unit."
|
|
::= { wtWebGraphThermoHygroGraphicsScale 13 }
|
|
|
|
wtWebGraphThermoHygroGraphicsScale4Unit OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 4: Unit."
|
|
::= { wtWebGraphThermoHygroGraphicsScale 14 }
|
|
|
|
|
|
-- wtWebGraphThermoHygroPorts Group
|
|
----------------------------
|
|
|
|
-- Table
|
|
|
|
wtWebGraphThermoHygroPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphThermoHygroPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the sensor number."
|
|
::= { wtWebGraphThermoHygroPorts 1 }
|
|
|
|
wtWebGraphThermoHygroPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphThermoHygroPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor parameters for the individual sensors."
|
|
INDEX { wtWebGraphThermoHygroSensorNo }
|
|
::= { wtWebGraphThermoHygroPortTable 1 }
|
|
|
|
WtWebGraphThermoHygroPortEntry ::= SEQUENCE {
|
|
wtWebGraphThermoHygroPortName OCTET STRING,
|
|
wtWebGraphThermoHygroPortText OCTET STRING,
|
|
wtWebGraphThermoHygroPortOffset1 OCTET STRING,
|
|
wtWebGraphThermoHygroPortTemperature1 OCTET STRING,
|
|
wtWebGraphThermoHygroPortOffset2 OCTET STRING,
|
|
wtWebGraphThermoHygroPortTemperature2 OCTET STRING,
|
|
wtWebGraphThermoHygroPortComment OCTET STRING
|
|
}
|
|
|
|
wtWebGraphThermoHygroPortName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the sensor."
|
|
::= { wtWebGraphThermoHygroPortEntry 1 }
|
|
|
|
wtWebGraphThermoHygroPortText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the sensor."
|
|
::= { wtWebGraphThermoHygroPortEntry 2 }
|
|
|
|
wtWebGraphThermoHygroPortOffset1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1."
|
|
::= { wtWebGraphThermoHygroPortEntry 3 }
|
|
|
|
wtWebGraphThermoHygroPortTemperature1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoHygroPortEntry 4 }
|
|
|
|
wtWebGraphThermoHygroPortOffset2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2."
|
|
::= { wtWebGraphThermoHygroPortEntry 5 }
|
|
|
|
wtWebGraphThermoHygroPortTemperature2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places."
|
|
::= { wtWebGraphThermoHygroPortEntry 6 }
|
|
|
|
wtWebGraphThermoHygroPortComment OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset calibration: informations of date, name of operator, reference devices."
|
|
::= { wtWebGraphThermoHygroPortEntry 7 }
|
|
|
|
wtWebGraphThermoHygroPortAltidude OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Altidude oh the Sensor over mean sea level (MSL)."
|
|
::= { wtWebGraphThermoHygroPorts 2 }
|
|
|
|
-- wtWebGraphThermoHygroManufact Group
|
|
----------------------------
|
|
|
|
wtWebGraphThermoHygroMfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtWebGraphThermoHygroManufact 1 }
|
|
|
|
wtWebGraphThermoHygroMfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtWebGraphThermoHygroManufact 2 }
|
|
|
|
wtWebGraphThermoHygroMfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtWebGraphThermoHygroManufact 3 }
|
|
|
|
wtWebGraphThermoHygroMfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtWebGraphThermoHygroManufact 4 }
|
|
|
|
wtWebGraphThermoHygroMfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtWebGraphThermoHygroManufact 5 }
|
|
|
|
wtWebGraphThermoHygroMfOrderNo OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer part number."
|
|
::= { wtWebGraphThermoHygroManufact 6 }
|
|
|
|
-- wtWebGraphThermoHygroDiag Group
|
|
----------------------------
|
|
|
|
wtWebGraphThermoHygroDiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtWebGraphThermoHygroDiag 1 }
|
|
|
|
wtWebGraphThermoHygroDiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtWebGraphThermoHygroDiag 2 }
|
|
|
|
wtWebGraphThermoHygroDiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtWebGraphThermoHygroDiagErrorMessage.
|
|
Errors are numbered from 1 to wtWebGraphThermoHygroDiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtWebGraphThermoHygroDiagErrorMessage."
|
|
::= { wtWebGraphThermoHygroDiag 3 }
|
|
|
|
wtWebGraphThermoHygroDiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtWebGraphThermoHygroDiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtWebGraphThermoHygroDiag 4 }
|
|
|
|
wtWebGraphThermoHygroDiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtWebGraphThermoHygroDiag 5 }
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtWebGraphThermoHygroAlert1 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoHygro
|
|
VARIABLES { wtWebGraphThermoHygroAlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 31
|
|
|
|
wtWebGraphThermoHygroAlert2 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoHygro
|
|
VARIABLES { wtWebGraphThermoHygroAlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 32
|
|
|
|
wtWebGraphThermoHygroAlert3 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoHygro
|
|
VARIABLES { wtWebGraphThermoHygroAlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 33
|
|
|
|
wtWebGraphThermoHygroAlert4 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoHygro
|
|
VARIABLES { wtWebGraphThermoHygroAlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 34
|
|
|
|
wtWebGraphThermoHygroAlert5 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoHygro
|
|
VARIABLES { wtWebGraphThermoHygroAlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 35
|
|
|
|
wtWebGraphThermoHygroAlert6 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoHygro
|
|
VARIABLES { wtWebGraphThermoHygroAlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 36
|
|
|
|
wtWebGraphThermoHygroAlert7 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoHygro
|
|
VARIABLES { wtWebGraphThermoHygroAlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 37
|
|
|
|
wtWebGraphThermoHygroAlert8 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoHygro
|
|
VARIABLES { wtWebGraphThermoHygroAlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 38
|
|
|
|
|
|
wtWebGraphThermoHygroAlert9 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoHygro
|
|
VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Release Alarm 1"
|
|
--#SUMMARY "Release Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 91
|
|
|
|
wtWebGraphThermoHygroAlert10 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoHygro
|
|
VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 92
|
|
|
|
wtWebGraphThermoHygroAlert11 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoHygro
|
|
VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 93
|
|
|
|
wtWebGraphThermoHygroAlert12 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoHygro
|
|
VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 94
|
|
|
|
wtWebGraphThermoHygroAlert13 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoHygro
|
|
VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 95
|
|
|
|
wtWebGraphThermoHygroAlert14 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoHygro
|
|
VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 96
|
|
|
|
wtWebGraphThermoHygroAlert15 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoHygro
|
|
VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 97
|
|
|
|
wtWebGraphThermoHygroAlert16 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoHygro
|
|
VARIABLES { wtWebGraphThermoHygroAlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 98
|
|
|
|
wtWebGraphThermoHygroAlertDiag TRAP-TYPE
|
|
ENTERPRISE wtWebGraphThermoHygro
|
|
VARIABLES {
|
|
wtWebGraphThermoHygroDiagErrorIndex,
|
|
wtWebGraphThermoHygroDiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Thermo-Hygrometer Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
END
|