-- ZyXEL Communications Corporation
-- Private Enterprise MIB definition
-- $Log: zyxel-AS.mib $
-- Revision 1.2 2006/06/08 09:18:11 niceguy
-- Revision 1.1 2005/11/23 12:47:58 niceguy
-- Initial revision
-- Revision 1.1 2005/08/18 13:30:38 Jeff
-- Initial revision
-- Revision 1.12 2004/06/08 10:12:38 jenny
-- Revision 1.11 2004/05/05 08:33:35 jennyhsu
-- Revision 1.10 2004/01/29 03:41:26 jennyhsu
-- Define DHCP option 82 setting
-- Revision 1.9 2003/09/19 04:57:58 jennyhsu
-- Add thermalSensorFailure trap. Change the syntax of
-- asDhcpRelayOption82Info to be DisplayString
-- Revision 1.8 2003/09/10 12:26:16 jennyhsu
-- add DHCP setup
-- Revision 1.7 2003/06/06 09:15:18 jennyhsu
-- Revise the descriptions of accessSwitchDSLConfTarget
-- Revision 1.6 2003/06/06 01:39:28 jennyhsu
-- Add objects for DSL configuration in batch mode
-- Revision 1.5 2003/05/27 08:12:45 jennyhsu
-- Add asPacketForwardingTable
-- Revision 1.4 2003/03/21 06:57:38 jennyhsu
-- remove the mask of accessSwitchSystemTemperature
-- Revision 1.3 2002/12/03 07:49:00 jennyhsu
-- Add accessSwitchSystemCurrentStatus into the variable binding of
-- temp, fan and voltage trap
-- Revision 1.2 2002/11/12 07:48:00 jennyhsu
-- Revision 1.1 2002/11/12 07:40:49 jennyhsu
-- Initial revision
ZYXEL-AS-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, IpAddress FROM RFC1155-SMI
OBJECT-TYPE FROM RFC-1212
DisplayString, ifIndex, PhysAddress
FROM RFC1213-MIB
TRAP-TYPE FROM RFC-1215
PortList FROM Q-BRIDGE-MIB
RowStatus FROM SNMPv2-TC
MacAddress, Timeout, BridgeId
FROM BRIDGE-MIB;
zyxel OBJECT IDENTIFIER ::= { enterprises 890 }
products OBJECT IDENTIFIER ::= { zyxel 1 }
accessSwitch OBJECT IDENTIFIER ::= { products 5 }
-- accessSwitch generic managed objects
accessSwitchCommon OBJECT IDENTIFIER ::= { accessSwitch 1 }
accessSwitchMgnt OBJECT IDENTIFIER ::= { accessSwitchCommon 1 }
accessSwitchStats OBJECT IDENTIFIER ::= { accessSwitchCommon 2 }
asMacStats OBJECT IDENTIFIER ::= { accessSwitchStats 1 }
-- accessSwitchMgnt subtree
-- System Status
accessSwitchSystemCurrentStatus OBJECT-TYPE
SYNTAX INTEGER(0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION "This variable indicates the status of the system.
The sysCurrentStatus is a bit map represented
as a sum, therefore, it can represent multiple defects
simultaneously. The sysNoDefect should be set if and only if
no other flag is set.
The various bit positions are:
1 sysNoDefect
2 sysOverHeat
3 sysFanRpmLow
4 sysVoltageLow
5 sysThermalSensorFailure"
::= { accessSwitchMgnt 1 }
-- System traps related managed objects
accessSwitchProblemCause OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The variable is the description of sytsem problem."
::= { accessSwitchMgnt 2 }
-- For AES-100, IES-1000 (SAM1008, AAM1008) only
accessSwitchSystemTemperature OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The variable is the current temperature in Celsius of the system."
::= { accessSwitchMgnt 3 }
-- Fan rpm table
accessSwitchFanRpmTable OBJECT-TYPE
SYNTAX SEQUENCE OF AccessSwitchFanRpmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains rpm information about the fans."
::= { accessSwitchMgnt 4 }
accessSwitchFanRpmEntry OBJECT-TYPE
SYNTAX AccessSwitchFanRpmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of rpm information for each fan."
INDEX { accessSwitchFanRpmIndex }
::= { accessSwitchFanRpmTable 1 }
AccessSwitchFanRpmEntry ::=
SEQUENCE {
accessSwitchFanRpmIndex INTEGER,
accessSwitchFanRpmCurValue INTEGER,
accessSwitchFanRpmMaxValue INTEGER,
accessSwitchFanRpmMinValue INTEGER,
accessSwitchFanRpmLowThresh INTEGER,
accessSwitchFanRpmDescr DisplayString
}
accessSwitchFanRpmIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The identity of the fan."
::= { accessSwitchFanRpmEntry 1 }
accessSwitchFanRpmCurValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current rpm of the fan."
::= { accessSwitchFanRpmEntry 2 }
accessSwitchFanRpmMaxValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum rpm ever performed by the fan."
::= { accessSwitchFanRpmEntry 3 }
accessSwitchFanRpmMinValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minimum rpm ever performed by the fan."
::= { accessSwitchFanRpmEntry 4 }
accessSwitchFanRpmLowThresh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The low threshold of the rpm of the fan. If the current rpm is less than
the threshold, the device will initiate the fanRpmLow trap."
::= { accessSwitchFanRpmEntry 5 }
accessSwitchFanRpmDescr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The description of the fan (e.g. location, function, etc.)."
::= { accessSwitchFanRpmEntry 6 }
-- Voltage table
accessSwitchVoltageTable OBJECT-TYPE
SYNTAX SEQUENCE OF AccessSwitchVoltageEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains voltage information about the system."
::= { accessSwitchMgnt 5 }
accessSwitchVoltageEntry OBJECT-TYPE
SYNTAX AccessSwitchVoltageEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of voltage information for each sensor."
INDEX { accessSwitchVoltageIndex }
::= { accessSwitchVoltageTable 1 }
AccessSwitchVoltageEntry ::=
SEQUENCE {
accessSwitchVoltageIndex INTEGER,
accessSwitchVoltageCurValue INTEGER,
accessSwitchVoltageMaxValue INTEGER,
accessSwitchVoltageMinValue INTEGER,
accessSwitchVoltageNominalValue INTEGER,
accessSwitchVoltageLowThresh INTEGER,
accessSwitchVoltageDescr DisplayString
}
accessSwitchVoltageIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The identity of the sensor."
::= { accessSwitchVoltageEntry 1 }
accessSwitchVoltageCurValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current voltage detected by the sensor (in milli-voltage)."
::= { accessSwitchVoltageEntry 2 }
accessSwitchVoltageMaxValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum voltage ever detected by the sensor (in milli-voltage)."
::= { accessSwitchVoltageEntry 3 }
accessSwitchVoltageMinValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minimum voltage ever detected by the sensor (in milli-voltage)."
::= { accessSwitchVoltageEntry 4 }
accessSwitchVoltageNominalValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The nominal voltage which the power should supply (in milli-voltage)."
::= { accessSwitchVoltageEntry 5 }
accessSwitchVoltageLowThresh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The low threshold of the voltage. If the current voltage is less than
the threshold, the device will initiate the voltageLow trap."
::= { accessSwitchVoltageEntry 6 }
accessSwitchVoltageDescr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The description of the voltage (e.g. location, nominal value, etc.)."
::= { accessSwitchVoltageEntry 7 }
-- System temperature table
accessSwitchSysTempTable OBJECT-TYPE
SYNTAX SEQUENCE OF AccessSwitchSysTempEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains temperature information about system."
::= { accessSwitchMgnt 6 }
accessSwitchSysTempEntry OBJECT-TYPE
SYNTAX AccessSwitchSysTempEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of temperature information for each sensor."
INDEX { accessSwitchSysTempIndex }
::= { accessSwitchSysTempTable 1 }
AccessSwitchSysTempEntry ::=
SEQUENCE {
accessSwitchSysTempIndex INTEGER,
accessSwitchSysTempCurValue INTEGER,
accessSwitchSysTempMaxValue INTEGER,
accessSwitchSysTempMinValue INTEGER,
accessSwitchSysTempHighThresh INTEGER,
accessSwitchSysTempDescr DisplayString
}
accessSwitchSysTempIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The identity of the sensor."
::= { accessSwitchSysTempEntry 1 }
accessSwitchSysTempCurValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current temperature detected in Celsius by the sensor."
::= { accessSwitchSysTempEntry 2 }
accessSwitchSysTempMaxValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum temperature ever detected in Celsius by the sensor."
::= { accessSwitchSysTempEntry 3 }
accessSwitchSysTempMinValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minimum temperature ever detected in Celsius by the sensor."
::= { accessSwitchSysTempEntry 4 }
accessSwitchSysTempHighThresh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The high threshold of the temperature in Celsius. If the current temperature
is higher than the threshold, the device will initiate the overheat trap."
::= { accessSwitchSysTempEntry 5 }
accessSwitchSysTempDescr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The description of the temperature sensor (e.g. location, function, etc.)."
::= { accessSwitchSysTempEntry 6 }
accessSwitchMaintenance OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The managed object is for system maintenance. When the EMS
wants to trigger the system maitenance operation, the EMS
shall send SNMP-SET message to set the corresponding bit value
to be 1. The various bit positions are:
BIT 1: config save
BIT 2: reset
BIT 3: local loopback test
BIT 4: remote loopback test"
::= { accessSwitchMgnt 7 }
accessSwitchMaintenancePort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The port which the maintenance operation should be performed on.
The value of 0 means the maintenance should be performed on the system."
::= { accessSwitchMgnt 8 }
accessSwitchMaxNumOfStaticVlans OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of static VLANs which the system supports"
::= { accessSwitchMgnt 9 }
-- Chassis information
ASSlotNum ::= INTEGER {
slot1(1),
slot2(2)
}
ASModuleType ::= INTEGER {
aes-100(1),
aes-100-1(2),
aam1008-61(3),
aam1008-63(4),
sam1008(5)
}
acccessSwitchChassisId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The chassis Id of the module"
::= { accessSwitchMgnt 10 }
accessSwitchSlotId OBJECT-TYPE
SYNTAX ASSlotNum
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot Id of the module"
::= { accessSwitchMgnt 11 }
accessSwitchModuleType OBJECT-TYPE
SYNTAX ASModuleType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the module"
::= { accessSwitchMgnt 12 }
accessSwitchFWVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The firmware version of the access switch."
::= { accessSwitchMgnt 13 }
accessSwitchDriverVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The driver version of the access port in this access switch"
::= { accessSwitchMgnt 14 }
accessSwitchModemCodeVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The modem code version of the access port in this access switch"
::= { accessSwitchMgnt 15 }
-- variables for provisioning DSL line in batch mode
accessSwitchDSLConfOps OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The managed object is for xDSL line configuration. When the EMS
wants to issue the desired operation, the EMS
shall send SNMP-SET message to set the corresponding bit value
to be 1. The various bit positions are:
BIT 1: enable port
BIT 2: disable port
BIT 3: set DSL mode
BIT 4: set profile"
::= { accessSwitchMgnt 16 }
accessSwitchDSLConfTarget OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The managed object is used for identify the target on which
the line configuration should be performed. The target is encoded
as:
Byte 1~4: reserved
Byte 5~7: each octet specifies a set of eight ports, with the first
octet specifying ports 1 through 8, etc.
Byte 8~10: reserved"
::= { accessSwitchMgnt 17 }
accessSwitchDSLConfProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The DSL profile name"
::= { accessSwitchMgnt 18 }
accessSwitchDSLConfMode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The DSL mode. The semantic for each bit is:
Bit 1: ADSL, G.lite
Bit 2: ADSL, G.dmt
Bit 3: ADSL, T1.413
Bit 4: ADSL, Auto"
::= { accessSwitchMgnt 19 }
-- Packet Forwarding Table
asPacketForwardingTable OBJECT-TYPE
SYNTAX SEQUENCE OF AsPacketForwardingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table includes the configuration of packet forwarding."
::= { accessSwitchMgnt 20 }
asPacketForwardingEntry OBJECT-TYPE
SYNTAX AsPacketForwardingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in asPacketForwardingTable."
INDEX { ifIndex }
::= { asPacketForwardingTable 1 }
AsPacketForwardingEntry ::=
SEQUENCE {
asPacketForwardingPortList PortList
}
asPacketForwardingPortList OBJECT-TYPE
SYNTAX PortList
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The list defines the ports to which the packets
will be forwarded."
::= { asPacketForwardingEntry 1 }
-- DHCP Setup
asDhcpRelayEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable DHCP relay function."
::= { accessSwitchMgnt 21 }
asDhcpRelayOption82Enable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable the relay agent information option."
::= { accessSwitchMgnt 22 }
asDhcpRelayOption82Info OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User specific relay agent information."
::= { accessSwitchMgnt 23 }
asMaxNumOfDhcpServers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of DHCP servers."
::= { accessSwitchMgnt 24 }
asDhcpServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF AsDhcpServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains DHCP server information."
::= { accessSwitchMgnt 25 }
asDhcpServerEntry OBJECT-TYPE
SYNTAX AsDhcpServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The entry of DHCP server table."
INDEX { asDhcpServerIp }
::= { asDhcpServerTable 1 }
AsDhcpServerEntry ::=
SEQUENCE {
asDhcpServerIp IpAddress,
asDhcpServerRowStatus RowStatus
}
asDhcpServerIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address of the DHCP server."
::= { asDhcpServerEntry 1 }
asDhcpServerRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The row status of the DHCP server entry."
::= { asDhcpServerEntry 2 }
-- SNMP setup, Trap Destination
-- asMaxNumberOfTrapDestinations OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "The max number of the trap destinations."
-- ::= { accessSwitchMgnt 26 }
--
-- asSNMPTrapDestTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF AsSNMPTrapDestEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "A table that contains SNMP trap destination information."
-- ::= { accessSwitchMgnt 27 }
-- asSNMPTrapDestEntry OBJECT-TYPE
-- SYNTAX AsSNMPTrapDestEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "The entry of SNMP trap destination table."
-- INDEX { asTrapDestIp, asTrapDestPort }
-- ::= { asSNMPTrapDestTable 1 }
-- AsSNMPTrapDestEntry ::=
-- SEQUENCE {
-- asTrapDestIp IpAddress,
-- asTrapDestPort INTEGER,
-- asTrapDestRowStatus RowStatus
-- }
-- asTrapDestIp OBJECT-TYPE
-- SYNTAX IpAddress
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "The IP address of the trap destination."
-- ::= { asSNMPTrapDestEntry 1 }
-- asTrapDestPort OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "The UDP port of the trap destination."
-- ::= { asSNMPTrapDestEntry 2 }
-- asTrapDestRowStatus OBJECT-TYPE
-- SYNTAX RowStatus
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "The row status of the trap destination entry."
-- ::= { asSNMPTrapDestEntry 3}
-- RADIUS Server setup
asMaxNumberOfRadiusServers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The max number of the RADIUS Servers."
::= { accessSwitchMgnt 28 }
asRadiusServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF AsRadiusServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains Radius Server information."
::= { accessSwitchMgnt 29 }
asRadiusServerEntry OBJECT-TYPE
SYNTAX AsRadiusServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The entry of Radius Server table."
INDEX { asRadiusServerIndex }
::= { asRadiusServerTable 1 }
AsRadiusServerEntry ::=
SEQUENCE {
asRadiusServerIndex INTEGER,
asRadiusServerIp IpAddress,
asRadiusServerPort INTEGER,
asRadiusSharedSecret DisplayString,
asRadiusServerRowStatus RowStatus
}
asRadiusServerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The identity of the RADIUS server."
::= { asRadiusServerEntry 1 }
asRadiusServerIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the Radius Server."
::= { asRadiusServerEntry 2 }
asRadiusServerPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The UDP port of the Radius Server."
::= { asRadiusServerEntry 3 }
asRadiusSharedSecret OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The shared secret of the Radius Server."
::= { asRadiusServerEntry 4 }
asRadiusServerRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The row status of the Radius Server entry."
::= { asRadiusServerEntry 5 }
-- 802.1x option
asDot1xEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable the 802.1x function."
::= { accessSwitchMgnt 30 }
-- 802.1x Table
asDot1xPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AsDot1xPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table includes the configuration of 802.1x."
::= { accessSwitchMgnt 31 }
asDot1xPortEntry OBJECT-TYPE
SYNTAX AsDot1xPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in asDot1xPortTable."
INDEX { ifIndex }
::= { asDot1xPortTable 1 }
AsDot1xPortEntry ::=
SEQUENCE {
asDot1xPortEnable INTEGER,
asDot1xPortControl INTEGER,
asDot1xPortReAuthEnable INTEGER,
asDot1xPortReAuthPeriod INTEGER
}
asDot1xPortEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The option defines if the port enables 802.1x
settings."
::= { asDot1xPortEntry 1 }
asDot1xPortControl OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
forceAuth(2),
forceUnAuth(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The configuration defines the 802.1x port control
type."
::= { asDot1xPortEntry 2 }
asDot1xPortReAuthEnable OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The option defines if the port enables 802.1x
re-authentication."
::= { asDot1xPortEntry 3 }
asDot1xPortReAuthPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The configuration defines the 802.1x
re-authentication period for each port."
::= { asDot1xPortEntry 4 }
--------------------
-- Statistics
--------------------
asMacDisplayTarget OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This managed object is a filter used for identify the target from which
the MAC addresses are learned in macTable. The target should be
IfIndex which is used for identifying subscriber ports
(e.g. 300 means all ports in slot 3 and 301 means port 1 in slot 3)."
::= { asMacStats 1 }
-- macTable
asMacTable OBJECT-TYPE
SYNTAX SEQUENCE OF AsMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains information about unicast
entries for which the bridge has forwarding and/or
filtering information. This information is used
by the transparent bridging function in
determining how to propagate a received frame."
::= { asMacStats 2 }
asMacEntry OBJECT-TYPE
SYNTAX AsMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of asMacTable."
INDEX { asMacAddress }
::= { asMacTable 1 }
AsMacEntry ::=
SEQUENCE {
asMacAddress MacAddress,
asMacPort INTEGER,
asMacStatus INTEGER
}
asMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unicast MAC address for which the bridge has
forwarding and/or filtering information."
::= { asMacEntry 1 }
asMacPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port from which the mac address has been learned."
::= { asMacEntry 2 }
asMacStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
invalid(2),
learned(3),
self(4),
mgmt(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of this entry."
::= { asMacEntry 3 }
-- accessSwitch specific traps
reboot TRAP-TYPE
ENTERPRISE accessSwitch
VARIABLES {
accessSwitchProblemCause
}
DESCRIPTION "Send a message to the manager that the system is going to reboot.
The variable is the reason why the system reboots."
::= 1
systemShutdown TRAP-TYPE
ENTERPRISE accessSwitch
VARIABLES {
accessSwitchProblemCause
}
DESCRIPTION "Send a message to the manager that the system is going to shutdown.
The variable is the reason that causes the system to shutdown."
::= 2
overheat TRAP-TYPE
ENTERPRISE accessSwitch
VARIABLES {
accessSwitchSysTempIndex,
accessSwitchSysTempCurValue,
accessSwitchSystemCurrentStatus
}
DESCRIPTION "Send a message to the manager that the system is overheated.
The variable in the binding list is the current temperature in Celsius
of the system."
::= 3
overheatOver TRAP-TYPE
ENTERPRISE accessSwitch
VARIABLES {
accessSwitchSysTempIndex,
accessSwitchSysTempCurValue,
accessSwitchSystemCurrentStatus
}
DESCRIPTION "Send a message to the manager that the overheated condition is over.
The variable in the binding list is the current temperature in Celsius
of the system."
::= 4
errLog TRAP-TYPE
ENTERPRISE accessSwitch
VARIABLES {
accessSwitchProblemCause
}
DESCRIPTION "Send a message to the manager that an error log is created in system.
The variable in the binding list is the content of the error log."
::= 5
fanRpmLow TRAP-TYPE
ENTERPRISE accessSwitch
VARIABLES {
accessSwitchFanRpmIndex,
accessSwitchFanRpmCurValue,
accessSwitchSystemCurrentStatus
}
DESCRIPTION "Send a message to the manager that the rpm of the fan is too low.
The variable in the binding list is the current rpm of the fan."
::= 6
fanRpmNormal TRAP-TYPE
ENTERPRISE accessSwitch
VARIABLES {
accessSwitchFanRpmIndex,
accessSwitchFanRpmCurValue,
accessSwitchSystemCurrentStatus
}
DESCRIPTION "Send a message to the manager that the low-rpm condition of the fan is over.
The variable in the binding list is the current rpm of the fan."
::= 7
voltageOutOfRange TRAP-TYPE
ENTERPRISE accessSwitch
VARIABLES {
accessSwitchVoltageIndex,
accessSwitchVoltageCurValue,
accessSwitchSystemCurrentStatus
}
DESCRIPTION "Send a message to the manager that the voltage of the system is out of range.
The variable in the binding list is the current voltage in volt
of the system."
::= 8
voltageNormal TRAP-TYPE
ENTERPRISE accessSwitch
VARIABLES {
accessSwitchVoltageIndex,
accessSwitchVoltageCurValue,
accessSwitchSystemCurrentStatus
}
DESCRIPTION "Send a message to the manager that the low-voltage condition is over.
The variable in the binding list is the current voltage in volt
of the system."
::= 9
systemMaintenanceFailure TRAP-TYPE
ENTERPRISE accessSwitch
VARIABLES {
accessSwitchProblemCause
}
DESCRIPTION "Send a message to the manager that the system maintence operation
fail. The variable in the variable binding indicates the problem."
::= 10
configChange TRAP-TYPE
ENTERPRISE accessSwitch
VARIABLES {
accessSwitchProblemCause
}
DESCRIPTION "Send a message to the manager that the system configuration
data is changed."
::= 11
thermalSensorFailure TRAP-TYPE
ENTERPRISE accessSwitch
VARIABLES {
accessSwitchProblemCause
}
DESCRIPTION "The trap signifies that the thermal sensor failed."
::= 12
END