1049 lines
32 KiB
Plaintext
1049 lines
32 KiB
Plaintext
-- ZyXEL Communications Corporation
|
|
-- Private Enterprise MIB definition
|
|
|
|
-- $Log: zyxel-AS.mib $
|
|
-- Revision 1.2 2006/06/08 09:18:11 niceguy
|
|
-- Revision 1.1 2005/11/23 12:47:58 niceguy
|
|
-- Initial revision
|
|
-- Revision 1.1 2005/08/18 13:30:38 Jeff
|
|
-- Initial revision
|
|
-- Revision 1.12 2004/06/08 10:12:38 jenny
|
|
-- Revision 1.11 2004/05/05 08:33:35 jennyhsu
|
|
-- Revision 1.10 2004/01/29 03:41:26 jennyhsu
|
|
-- Define DHCP option 82 setting
|
|
-- Revision 1.9 2003/09/19 04:57:58 jennyhsu
|
|
-- Add thermalSensorFailure trap. Change the syntax of
|
|
-- asDhcpRelayOption82Info to be DisplayString
|
|
-- Revision 1.8 2003/09/10 12:26:16 jennyhsu
|
|
-- add DHCP setup
|
|
-- Revision 1.7 2003/06/06 09:15:18 jennyhsu
|
|
-- Revise the descriptions of accessSwitchDSLConfTarget
|
|
-- Revision 1.6 2003/06/06 01:39:28 jennyhsu
|
|
-- Add objects for DSL configuration in batch mode
|
|
-- Revision 1.5 2003/05/27 08:12:45 jennyhsu
|
|
-- Add asPacketForwardingTable
|
|
-- Revision 1.4 2003/03/21 06:57:38 jennyhsu
|
|
-- remove the mask of accessSwitchSystemTemperature
|
|
-- Revision 1.3 2002/12/03 07:49:00 jennyhsu
|
|
-- Add accessSwitchSystemCurrentStatus into the variable binding of
|
|
-- temp, fan and voltage trap
|
|
-- Revision 1.2 2002/11/12 07:48:00 jennyhsu
|
|
-- Revision 1.1 2002/11/12 07:40:49 jennyhsu
|
|
-- Initial revision
|
|
|
|
|
|
ZYXEL-AS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
enterprises, IpAddress FROM RFC1155-SMI
|
|
OBJECT-TYPE FROM RFC-1212
|
|
DisplayString, ifIndex, PhysAddress
|
|
FROM RFC1213-MIB
|
|
TRAP-TYPE FROM RFC-1215
|
|
PortList FROM Q-BRIDGE-MIB
|
|
RowStatus FROM SNMPv2-TC
|
|
MacAddress, Timeout, BridgeId
|
|
FROM BRIDGE-MIB;
|
|
|
|
|
|
zyxel OBJECT IDENTIFIER ::= { enterprises 890 }
|
|
products OBJECT IDENTIFIER ::= { zyxel 1 }
|
|
accessSwitch OBJECT IDENTIFIER ::= { products 5 }
|
|
|
|
-- accessSwitch generic managed objects
|
|
accessSwitchCommon OBJECT IDENTIFIER ::= { accessSwitch 1 }
|
|
accessSwitchMgnt OBJECT IDENTIFIER ::= { accessSwitchCommon 1 }
|
|
|
|
accessSwitchStats OBJECT IDENTIFIER ::= { accessSwitchCommon 2 }
|
|
asMacStats OBJECT IDENTIFIER ::= { accessSwitchStats 1 }
|
|
|
|
-- accessSwitchMgnt subtree
|
|
|
|
-- System Status
|
|
accessSwitchSystemCurrentStatus OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This variable indicates the status of the system.
|
|
The sysCurrentStatus is a bit map represented
|
|
as a sum, therefore, it can represent multiple defects
|
|
simultaneously. The sysNoDefect should be set if and only if
|
|
no other flag is set.
|
|
|
|
The various bit positions are:
|
|
1 sysNoDefect
|
|
2 sysOverHeat
|
|
3 sysFanRpmLow
|
|
4 sysVoltageLow
|
|
5 sysThermalSensorFailure"
|
|
::= { accessSwitchMgnt 1 }
|
|
|
|
-- System traps related managed objects
|
|
|
|
accessSwitchProblemCause OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The variable is the description of sytsem problem."
|
|
::= { accessSwitchMgnt 2 }
|
|
|
|
-- For AES-100, IES-1000 (SAM1008, AAM1008) only
|
|
accessSwitchSystemTemperature OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The variable is the current temperature in Celsius of the system."
|
|
::= { accessSwitchMgnt 3 }
|
|
|
|
|
|
-- Fan rpm table
|
|
|
|
accessSwitchFanRpmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AccessSwitchFanRpmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table that contains rpm information about the fans."
|
|
::= { accessSwitchMgnt 4 }
|
|
|
|
accessSwitchFanRpmEntry OBJECT-TYPE
|
|
SYNTAX AccessSwitchFanRpmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of rpm information for each fan."
|
|
INDEX { accessSwitchFanRpmIndex }
|
|
::= { accessSwitchFanRpmTable 1 }
|
|
|
|
AccessSwitchFanRpmEntry ::=
|
|
SEQUENCE {
|
|
accessSwitchFanRpmIndex INTEGER,
|
|
accessSwitchFanRpmCurValue INTEGER,
|
|
accessSwitchFanRpmMaxValue INTEGER,
|
|
accessSwitchFanRpmMinValue INTEGER,
|
|
accessSwitchFanRpmLowThresh INTEGER,
|
|
accessSwitchFanRpmDescr DisplayString
|
|
}
|
|
|
|
accessSwitchFanRpmIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The identity of the fan."
|
|
::= { accessSwitchFanRpmEntry 1 }
|
|
|
|
accessSwitchFanRpmCurValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current rpm of the fan."
|
|
::= { accessSwitchFanRpmEntry 2 }
|
|
|
|
accessSwitchFanRpmMaxValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum rpm ever performed by the fan."
|
|
::= { accessSwitchFanRpmEntry 3 }
|
|
|
|
accessSwitchFanRpmMinValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum rpm ever performed by the fan."
|
|
::= { accessSwitchFanRpmEntry 4 }
|
|
|
|
accessSwitchFanRpmLowThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low threshold of the rpm of the fan. If the current rpm is less than
|
|
the threshold, the device will initiate the fanRpmLow trap."
|
|
::= { accessSwitchFanRpmEntry 5 }
|
|
|
|
accessSwitchFanRpmDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The description of the fan (e.g. location, function, etc.)."
|
|
::= { accessSwitchFanRpmEntry 6 }
|
|
|
|
|
|
-- Voltage table
|
|
|
|
accessSwitchVoltageTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AccessSwitchVoltageEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table that contains voltage information about the system."
|
|
::= { accessSwitchMgnt 5 }
|
|
|
|
accessSwitchVoltageEntry OBJECT-TYPE
|
|
SYNTAX AccessSwitchVoltageEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of voltage information for each sensor."
|
|
INDEX { accessSwitchVoltageIndex }
|
|
::= { accessSwitchVoltageTable 1 }
|
|
|
|
AccessSwitchVoltageEntry ::=
|
|
SEQUENCE {
|
|
accessSwitchVoltageIndex INTEGER,
|
|
accessSwitchVoltageCurValue INTEGER,
|
|
accessSwitchVoltageMaxValue INTEGER,
|
|
accessSwitchVoltageMinValue INTEGER,
|
|
accessSwitchVoltageNominalValue INTEGER,
|
|
accessSwitchVoltageLowThresh INTEGER,
|
|
accessSwitchVoltageDescr DisplayString
|
|
}
|
|
|
|
accessSwitchVoltageIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The identity of the sensor."
|
|
::= { accessSwitchVoltageEntry 1 }
|
|
|
|
accessSwitchVoltageCurValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current voltage detected by the sensor (in milli-voltage)."
|
|
::= { accessSwitchVoltageEntry 2 }
|
|
|
|
accessSwitchVoltageMaxValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum voltage ever detected by the sensor (in milli-voltage)."
|
|
::= { accessSwitchVoltageEntry 3 }
|
|
|
|
accessSwitchVoltageMinValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum voltage ever detected by the sensor (in milli-voltage)."
|
|
::= { accessSwitchVoltageEntry 4 }
|
|
|
|
accessSwitchVoltageNominalValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The nominal voltage which the power should supply (in milli-voltage)."
|
|
::= { accessSwitchVoltageEntry 5 }
|
|
|
|
accessSwitchVoltageLowThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The low threshold of the voltage. If the current voltage is less than
|
|
the threshold, the device will initiate the voltageLow trap."
|
|
::= { accessSwitchVoltageEntry 6 }
|
|
|
|
accessSwitchVoltageDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The description of the voltage (e.g. location, nominal value, etc.)."
|
|
::= { accessSwitchVoltageEntry 7 }
|
|
|
|
|
|
-- System temperature table
|
|
|
|
accessSwitchSysTempTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AccessSwitchSysTempEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table that contains temperature information about system."
|
|
::= { accessSwitchMgnt 6 }
|
|
|
|
accessSwitchSysTempEntry OBJECT-TYPE
|
|
SYNTAX AccessSwitchSysTempEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of temperature information for each sensor."
|
|
INDEX { accessSwitchSysTempIndex }
|
|
::= { accessSwitchSysTempTable 1 }
|
|
|
|
AccessSwitchSysTempEntry ::=
|
|
SEQUENCE {
|
|
accessSwitchSysTempIndex INTEGER,
|
|
accessSwitchSysTempCurValue INTEGER,
|
|
accessSwitchSysTempMaxValue INTEGER,
|
|
accessSwitchSysTempMinValue INTEGER,
|
|
accessSwitchSysTempHighThresh INTEGER,
|
|
accessSwitchSysTempDescr DisplayString
|
|
}
|
|
|
|
accessSwitchSysTempIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The identity of the sensor."
|
|
::= { accessSwitchSysTempEntry 1 }
|
|
|
|
accessSwitchSysTempCurValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current temperature detected in Celsius by the sensor."
|
|
::= { accessSwitchSysTempEntry 2 }
|
|
|
|
accessSwitchSysTempMaxValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum temperature ever detected in Celsius by the sensor."
|
|
::= { accessSwitchSysTempEntry 3 }
|
|
|
|
accessSwitchSysTempMinValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum temperature ever detected in Celsius by the sensor."
|
|
::= { accessSwitchSysTempEntry 4 }
|
|
|
|
accessSwitchSysTempHighThresh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The high threshold of the temperature in Celsius. If the current temperature
|
|
is higher than the threshold, the device will initiate the overheat trap."
|
|
::= { accessSwitchSysTempEntry 5 }
|
|
|
|
accessSwitchSysTempDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The description of the temperature sensor (e.g. location, function, etc.)."
|
|
|
|
::= { accessSwitchSysTempEntry 6 }
|
|
|
|
accessSwitchMaintenance OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The managed object is for system maintenance. When the EMS
|
|
wants to trigger the system maitenance operation, the EMS
|
|
shall send SNMP-SET message to set the corresponding bit value
|
|
to be 1. The various bit positions are:
|
|
BIT 1: config save
|
|
BIT 2: reset
|
|
BIT 3: local loopback test
|
|
BIT 4: remote loopback test"
|
|
::= { accessSwitchMgnt 7 }
|
|
|
|
accessSwitchMaintenancePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port which the maintenance operation should be performed on.
|
|
The value of 0 means the maintenance should be performed on the system."
|
|
::= { accessSwitchMgnt 8 }
|
|
|
|
accessSwitchMaxNumOfStaticVlans OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of static VLANs which the system supports"
|
|
::= { accessSwitchMgnt 9 }
|
|
|
|
-- Chassis information
|
|
|
|
ASSlotNum ::= INTEGER {
|
|
slot1(1),
|
|
slot2(2)
|
|
}
|
|
|
|
ASModuleType ::= INTEGER {
|
|
aes-100(1),
|
|
aes-100-1(2),
|
|
aam1008-61(3),
|
|
aam1008-63(4),
|
|
sam1008(5)
|
|
}
|
|
|
|
|
|
acccessSwitchChassisId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The chassis Id of the module"
|
|
::= { accessSwitchMgnt 10 }
|
|
|
|
accessSwitchSlotId OBJECT-TYPE
|
|
SYNTAX ASSlotNum
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The slot Id of the module"
|
|
::= { accessSwitchMgnt 11 }
|
|
|
|
accessSwitchModuleType OBJECT-TYPE
|
|
SYNTAX ASModuleType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of the module"
|
|
::= { accessSwitchMgnt 12 }
|
|
|
|
|
|
accessSwitchFWVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware version of the access switch."
|
|
::= { accessSwitchMgnt 13 }
|
|
|
|
accessSwitchDriverVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The driver version of the access port in this access switch"
|
|
::= { accessSwitchMgnt 14 }
|
|
|
|
accessSwitchModemCodeVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The modem code version of the access port in this access switch"
|
|
::= { accessSwitchMgnt 15 }
|
|
|
|
-- variables for provisioning DSL line in batch mode
|
|
|
|
accessSwitchDSLConfOps OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The managed object is for xDSL line configuration. When the EMS
|
|
wants to issue the desired operation, the EMS
|
|
shall send SNMP-SET message to set the corresponding bit value
|
|
to be 1. The various bit positions are:
|
|
BIT 1: enable port
|
|
BIT 2: disable port
|
|
BIT 3: set DSL mode
|
|
BIT 4: set profile"
|
|
::= { accessSwitchMgnt 16 }
|
|
|
|
accessSwitchDSLConfTarget OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The managed object is used for identify the target on which
|
|
the line configuration should be performed. The target is encoded
|
|
as:
|
|
Byte 1~4: reserved
|
|
Byte 5~7: each octet specifies a set of eight ports, with the first
|
|
octet specifying ports 1 through 8, etc.
|
|
Byte 8~10: reserved"
|
|
::= { accessSwitchMgnt 17 }
|
|
|
|
accessSwitchDSLConfProfileName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..31))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The DSL profile name"
|
|
::= { accessSwitchMgnt 18 }
|
|
|
|
accessSwitchDSLConfMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The DSL mode. The semantic for each bit is:
|
|
Bit 1: ADSL, G.lite
|
|
Bit 2: ADSL, G.dmt
|
|
Bit 3: ADSL, T1.413
|
|
Bit 4: ADSL, Auto"
|
|
::= { accessSwitchMgnt 19 }
|
|
|
|
-- Packet Forwarding Table
|
|
|
|
asPacketForwardingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AsPacketForwardingEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table includes the configuration of packet forwarding."
|
|
::= { accessSwitchMgnt 20 }
|
|
|
|
asPacketForwardingEntry OBJECT-TYPE
|
|
SYNTAX AsPacketForwardingEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry in asPacketForwardingTable."
|
|
INDEX { ifIndex }
|
|
::= { asPacketForwardingTable 1 }
|
|
|
|
AsPacketForwardingEntry ::=
|
|
SEQUENCE {
|
|
asPacketForwardingPortList PortList
|
|
}
|
|
|
|
asPacketForwardingPortList OBJECT-TYPE
|
|
SYNTAX PortList
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The list defines the ports to which the packets
|
|
will be forwarded."
|
|
::= { asPacketForwardingEntry 1 }
|
|
|
|
|
|
-- DHCP Setup
|
|
|
|
asDhcpRelayEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/disable DHCP relay function."
|
|
::= { accessSwitchMgnt 21 }
|
|
|
|
asDhcpRelayOption82Enable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/disable the relay agent information option."
|
|
::= { accessSwitchMgnt 22 }
|
|
|
|
asDhcpRelayOption82Info OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User specific relay agent information."
|
|
::= { accessSwitchMgnt 23 }
|
|
|
|
asMaxNumOfDhcpServers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of DHCP servers."
|
|
::= { accessSwitchMgnt 24 }
|
|
|
|
asDhcpServerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AsDhcpServerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table that contains DHCP server information."
|
|
::= { accessSwitchMgnt 25 }
|
|
|
|
asDhcpServerEntry OBJECT-TYPE
|
|
SYNTAX AsDhcpServerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The entry of DHCP server table."
|
|
INDEX { asDhcpServerIp }
|
|
::= { asDhcpServerTable 1 }
|
|
|
|
AsDhcpServerEntry ::=
|
|
SEQUENCE {
|
|
asDhcpServerIp IpAddress,
|
|
asDhcpServerRowStatus RowStatus
|
|
}
|
|
|
|
asDhcpServerIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the DHCP server."
|
|
::= { asDhcpServerEntry 1 }
|
|
|
|
asDhcpServerRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The row status of the DHCP server entry."
|
|
::= { asDhcpServerEntry 2 }
|
|
|
|
|
|
|
|
|
|
-- SNMP setup, Trap Destination
|
|
|
|
-- asMaxNumberOfTrapDestinations OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "The max number of the trap destinations."
|
|
-- ::= { accessSwitchMgnt 26 }
|
|
--
|
|
-- asSNMPTrapDestTable OBJECT-TYPE
|
|
-- SYNTAX SEQUENCE OF AsSNMPTrapDestEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "A table that contains SNMP trap destination information."
|
|
-- ::= { accessSwitchMgnt 27 }
|
|
|
|
-- asSNMPTrapDestEntry OBJECT-TYPE
|
|
-- SYNTAX AsSNMPTrapDestEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "The entry of SNMP trap destination table."
|
|
-- INDEX { asTrapDestIp, asTrapDestPort }
|
|
-- ::= { asSNMPTrapDestTable 1 }
|
|
|
|
-- AsSNMPTrapDestEntry ::=
|
|
-- SEQUENCE {
|
|
-- asTrapDestIp IpAddress,
|
|
-- asTrapDestPort INTEGER,
|
|
-- asTrapDestRowStatus RowStatus
|
|
-- }
|
|
|
|
-- asTrapDestIp OBJECT-TYPE
|
|
-- SYNTAX IpAddress
|
|
-- ACCESS read-write
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "The IP address of the trap destination."
|
|
-- ::= { asSNMPTrapDestEntry 1 }
|
|
|
|
|
|
-- asTrapDestPort OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-write
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "The UDP port of the trap destination."
|
|
-- ::= { asSNMPTrapDestEntry 2 }
|
|
|
|
-- asTrapDestRowStatus OBJECT-TYPE
|
|
-- SYNTAX RowStatus
|
|
-- ACCESS read-write
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "The row status of the trap destination entry."
|
|
-- ::= { asSNMPTrapDestEntry 3}
|
|
|
|
|
|
|
|
|
|
|
|
-- RADIUS Server setup
|
|
|
|
asMaxNumberOfRadiusServers OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The max number of the RADIUS Servers."
|
|
::= { accessSwitchMgnt 28 }
|
|
|
|
asRadiusServerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AsRadiusServerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table that contains Radius Server information."
|
|
::= { accessSwitchMgnt 29 }
|
|
|
|
asRadiusServerEntry OBJECT-TYPE
|
|
SYNTAX AsRadiusServerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The entry of Radius Server table."
|
|
INDEX { asRadiusServerIndex }
|
|
::= { asRadiusServerTable 1 }
|
|
|
|
AsRadiusServerEntry ::=
|
|
SEQUENCE {
|
|
asRadiusServerIndex INTEGER,
|
|
asRadiusServerIp IpAddress,
|
|
asRadiusServerPort INTEGER,
|
|
asRadiusSharedSecret DisplayString,
|
|
asRadiusServerRowStatus RowStatus
|
|
}
|
|
|
|
asRadiusServerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The identity of the RADIUS server."
|
|
::= { asRadiusServerEntry 1 }
|
|
|
|
asRadiusServerIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the Radius Server."
|
|
::= { asRadiusServerEntry 2 }
|
|
|
|
|
|
asRadiusServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UDP port of the Radius Server."
|
|
::= { asRadiusServerEntry 3 }
|
|
|
|
asRadiusSharedSecret OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The shared secret of the Radius Server."
|
|
::= { asRadiusServerEntry 4 }
|
|
|
|
asRadiusServerRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The row status of the Radius Server entry."
|
|
::= { asRadiusServerEntry 5 }
|
|
|
|
|
|
|
|
|
|
-- 802.1x option
|
|
|
|
asDot1xEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable/disable the 802.1x function."
|
|
::= { accessSwitchMgnt 30 }
|
|
|
|
|
|
|
|
-- 802.1x Table
|
|
|
|
asDot1xPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AsDot1xPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table includes the configuration of 802.1x."
|
|
::= { accessSwitchMgnt 31 }
|
|
|
|
asDot1xPortEntry OBJECT-TYPE
|
|
SYNTAX AsDot1xPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry in asDot1xPortTable."
|
|
INDEX { ifIndex }
|
|
::= { asDot1xPortTable 1 }
|
|
|
|
AsDot1xPortEntry ::=
|
|
SEQUENCE {
|
|
asDot1xPortEnable INTEGER,
|
|
asDot1xPortControl INTEGER,
|
|
asDot1xPortReAuthEnable INTEGER,
|
|
asDot1xPortReAuthPeriod INTEGER
|
|
}
|
|
|
|
asDot1xPortEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The option defines if the port enables 802.1x
|
|
settings."
|
|
::= { asDot1xPortEntry 1 }
|
|
|
|
asDot1xPortControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
auto(1),
|
|
forceAuth(2),
|
|
forceUnAuth(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The configuration defines the 802.1x port control
|
|
type."
|
|
::= { asDot1xPortEntry 2 }
|
|
|
|
asDot1xPortReAuthEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The option defines if the port enables 802.1x
|
|
re-authentication."
|
|
::= { asDot1xPortEntry 3 }
|
|
|
|
asDot1xPortReAuthPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The configuration defines the 802.1x
|
|
re-authentication period for each port."
|
|
::= { asDot1xPortEntry 4 }
|
|
|
|
|
|
--------------------
|
|
-- Statistics
|
|
--------------------
|
|
|
|
asMacDisplayTarget OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This managed object is a filter used for identify the target from which
|
|
the MAC addresses are learned in macTable. The target should be
|
|
IfIndex which is used for identifying subscriber ports
|
|
(e.g. 300 means all ports in slot 3 and 301 means port 1 in slot 3)."
|
|
::= { asMacStats 1 }
|
|
|
|
-- macTable
|
|
|
|
asMacTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AsMacEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains information about unicast
|
|
entries for which the bridge has forwarding and/or
|
|
filtering information. This information is used
|
|
by the transparent bridging function in
|
|
determining how to propagate a received frame."
|
|
::= { asMacStats 2 }
|
|
|
|
asMacEntry OBJECT-TYPE
|
|
SYNTAX AsMacEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry of asMacTable."
|
|
INDEX { asMacAddress }
|
|
::= { asMacTable 1 }
|
|
|
|
AsMacEntry ::=
|
|
SEQUENCE {
|
|
asMacAddress MacAddress,
|
|
asMacPort INTEGER,
|
|
asMacStatus INTEGER
|
|
}
|
|
|
|
asMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unicast MAC address for which the bridge has
|
|
forwarding and/or filtering information."
|
|
::= { asMacEntry 1 }
|
|
|
|
asMacPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port from which the mac address has been learned."
|
|
::= { asMacEntry 2 }
|
|
|
|
asMacStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
invalid(2),
|
|
learned(3),
|
|
self(4),
|
|
mgmt(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this entry."
|
|
::= { asMacEntry 3 }
|
|
|
|
|
|
|
|
|
|
|
|
|
|
-- accessSwitch specific traps
|
|
|
|
reboot TRAP-TYPE
|
|
ENTERPRISE accessSwitch
|
|
VARIABLES {
|
|
accessSwitchProblemCause
|
|
}
|
|
DESCRIPTION "Send a message to the manager that the system is going to reboot.
|
|
The variable is the reason why the system reboots."
|
|
::= 1
|
|
|
|
systemShutdown TRAP-TYPE
|
|
ENTERPRISE accessSwitch
|
|
VARIABLES {
|
|
accessSwitchProblemCause
|
|
}
|
|
DESCRIPTION "Send a message to the manager that the system is going to shutdown.
|
|
The variable is the reason that causes the system to shutdown."
|
|
::= 2
|
|
|
|
overheat TRAP-TYPE
|
|
ENTERPRISE accessSwitch
|
|
VARIABLES {
|
|
accessSwitchSysTempIndex,
|
|
accessSwitchSysTempCurValue,
|
|
accessSwitchSystemCurrentStatus
|
|
}
|
|
DESCRIPTION "Send a message to the manager that the system is overheated.
|
|
The variable in the binding list is the current temperature in Celsius
|
|
of the system."
|
|
::= 3
|
|
|
|
overheatOver TRAP-TYPE
|
|
ENTERPRISE accessSwitch
|
|
VARIABLES {
|
|
accessSwitchSysTempIndex,
|
|
accessSwitchSysTempCurValue,
|
|
accessSwitchSystemCurrentStatus
|
|
}
|
|
DESCRIPTION "Send a message to the manager that the overheated condition is over.
|
|
The variable in the binding list is the current temperature in Celsius
|
|
of the system."
|
|
::= 4
|
|
|
|
errLog TRAP-TYPE
|
|
ENTERPRISE accessSwitch
|
|
VARIABLES {
|
|
accessSwitchProblemCause
|
|
}
|
|
DESCRIPTION "Send a message to the manager that an error log is created in system.
|
|
The variable in the binding list is the content of the error log."
|
|
::= 5
|
|
|
|
fanRpmLow TRAP-TYPE
|
|
ENTERPRISE accessSwitch
|
|
VARIABLES {
|
|
accessSwitchFanRpmIndex,
|
|
accessSwitchFanRpmCurValue,
|
|
accessSwitchSystemCurrentStatus
|
|
}
|
|
DESCRIPTION "Send a message to the manager that the rpm of the fan is too low.
|
|
The variable in the binding list is the current rpm of the fan."
|
|
::= 6
|
|
|
|
fanRpmNormal TRAP-TYPE
|
|
ENTERPRISE accessSwitch
|
|
VARIABLES {
|
|
accessSwitchFanRpmIndex,
|
|
accessSwitchFanRpmCurValue,
|
|
accessSwitchSystemCurrentStatus
|
|
}
|
|
DESCRIPTION "Send a message to the manager that the low-rpm condition of the fan is over.
|
|
The variable in the binding list is the current rpm of the fan."
|
|
::= 7
|
|
|
|
voltageOutOfRange TRAP-TYPE
|
|
ENTERPRISE accessSwitch
|
|
VARIABLES {
|
|
accessSwitchVoltageIndex,
|
|
accessSwitchVoltageCurValue,
|
|
accessSwitchSystemCurrentStatus
|
|
}
|
|
DESCRIPTION "Send a message to the manager that the voltage of the system is out of range.
|
|
The variable in the binding list is the current voltage in volt
|
|
of the system."
|
|
::= 8
|
|
|
|
voltageNormal TRAP-TYPE
|
|
ENTERPRISE accessSwitch
|
|
VARIABLES {
|
|
accessSwitchVoltageIndex,
|
|
accessSwitchVoltageCurValue,
|
|
accessSwitchSystemCurrentStatus
|
|
}
|
|
DESCRIPTION "Send a message to the manager that the low-voltage condition is over.
|
|
The variable in the binding list is the current voltage in volt
|
|
of the system."
|
|
::= 9
|
|
|
|
systemMaintenanceFailure TRAP-TYPE
|
|
ENTERPRISE accessSwitch
|
|
VARIABLES {
|
|
accessSwitchProblemCause
|
|
}
|
|
DESCRIPTION "Send a message to the manager that the system maintence operation
|
|
fail. The variable in the variable binding indicates the problem."
|
|
::= 10
|
|
|
|
configChange TRAP-TYPE
|
|
ENTERPRISE accessSwitch
|
|
VARIABLES {
|
|
accessSwitchProblemCause
|
|
}
|
|
DESCRIPTION "Send a message to the manager that the system configuration
|
|
data is changed."
|
|
::= 11
|
|
|
|
thermalSensorFailure TRAP-TYPE
|
|
ENTERPRISE accessSwitch
|
|
VARIABLES {
|
|
accessSwitchProblemCause
|
|
}
|
|
DESCRIPTION "The trap signifies that the thermal sensor failed."
|
|
::= 12
|
|
|
|
END |